Comparison of two techniques of robot-aided upper limb exercise training after stroke.
Stein, Joel; Krebs, Hermano Igo; Frontera, Walter R; Fasoli, Susan E; Hughes, Richard; Hogan, Neville
2004-09-01
This study examined whether incorporating progressive resistive training into robot-aided exercise training provides incremental benefits over active-assisted robot-aided exercise for the upper limb after stroke. A total of 47 individuals at least 1 yr poststroke were enrolled in this 6-wk training protocol. Paretic upper limb motor abilities were evaluated using clinical measures and a robot-based assessment to determine eligibility for robot-aided progressive resistive training at study entry. Subjects capable of participating in resistance training were randomized to receive either active-assisted robot-aided exercises or robot-aided progressive resistance training. Subjects who were incapable of participating in resistance training underwent active-assisted robotic therapy and were again screened for eligibility after 3 wks of robotic therapy. Those subjects capable of participating in resistance training at 3 wks were then randomized to receive either robot-aided resistance training or to continue with robot-aided active-assisted training. One subject withdrew due to unrelated medical issues, and data for the remaining 46 subjects were analyzed. Subjects in all groups showed improvement in measures of motor control (mean increase in Fugl-Meyer of 3.3; 95% confidence interval, 2.2-4.4) and maximal force (mean increase in maximal force of 3.5 N, P = 0.027) over the course of robot-aided exercise training. No differences in outcome measures were observed between the resistance training groups and the matched active-assisted training groups. Subjects' ability to perform the robotic task at the time of group assignment predicted the magnitude of the gain in motor control. The incorporation of robot-aided progressive resistance exercises into a program of robot-aided exercise did not favorably or negatively affect the gains in motor control or strength associated with this training, though interpretation of these results is limited by sample size. Individuals with better motor control at baseline experienced greater increases in motor control with robotic training.
A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities.
Eiammanussakul, Trinnachoke; Sangveraphunsiri, Viboon
2018-01-01
Robots for stroke rehabilitation at the lower limbs in sitting/lying position have been developed extensively. Some of them have been applied in clinics and shown the potential of the recovery of poststroke patients who suffer from hemiparesis. These robots were developed to provide training at different joints of lower limbs with various activities and modalities. This article reviews the training activities that were realized by rehabilitation robots in literature, in order to offer insights for developing a novel robot suitable for stroke rehabilitation. The control system of the lower limb rehabilitation robot in sitting position that was introduced in the previous work is discussed in detail to demonstrate the behavior of the robot while training a subject. The nonlinear impedance control law, based on active assistive control strategy, is able to define the response of the robot with more specifications while the passivity property and the robustness of the system is verified. A preliminary experiment is conducted on a healthy subject to show that the robot is able to perform active assistive exercises with various training activities and assist the subject to complete the training with desired level of assistance.
2010-01-01
Background Manual body weight supported treadmill training and robot-aided treadmill training are frequently used techniques for the gait rehabilitation of individuals after stroke and spinal cord injury. Current evidence suggests that robot-aided gait training may be improved by making robotic behavior more patient-cooperative. In this study, we have investigated the immediate effects of patient-cooperative versus non-cooperative robot-aided gait training on individuals with incomplete spinal cord injury (iSCI). Methods Eleven patients with iSCI participated in a single training session with the gait rehabilitation robot Lokomat. The patients were exposed to four different training modes in random order: During both non-cooperative position control and compliant impedance control, fixed timing of movements was provided. During two variants of the patient-cooperative path control approach, free timing of movements was enabled and the robot provided only spatial guidance. The two variants of the path control approach differed in the amount of additional support, which was either individually adjusted or exaggerated. Joint angles and torques of the robot as well as muscle activity and heart rate of the patients were recorded. Kinematic variability, interaction torques, heart rate and muscle activity were compared between the different conditions. Results Patients showed more spatial and temporal kinematic variability, reduced interaction torques, a higher increase of heart rate and more muscle activity in the patient-cooperative path control mode with individually adjusted support than in the non-cooperative position control mode. In the compliant impedance control mode, spatial kinematic variability was increased and interaction torques were reduced, but temporal kinematic variability, heart rate and muscle activity were not significantly higher than in the position control mode. Conclusions Patient-cooperative robot-aided gait training with free timing of movements made individuals with iSCI participate more actively and with larger kinematic variability than non-cooperative, position-controlled robot-aided gait training. PMID:20828422
2012-01-01
Background Functional training is becoming the state-of-the-art therapy approach for rehabilitation of individuals after stroke and spinal cord injury. Robot-aided treadmill training reduces personnel effort, especially when treating severely affected patients. Improving rehabilitation robots towards more patient-cooperative behavior may further increase the effects of robot-aided training. This pilot study aims at investigating the feasibility of applying patient-cooperative robot-aided gait rehabilitation to stroke and incomplete spinal cord injury during a therapy period of four weeks. Short-term effects within one training session as well as the effects of the training on walking function are evaluated. Methods Two individuals with chronic incomplete spinal cord injury and two with chronic stroke trained with the Lokomat gait rehabilitation robot which was operated in a new, patient-cooperative mode for a period of four weeks with four training sessions of 45 min per week. At baseline, after two and after four weeks, walking function was assessed with the ten meter walking test. Additionally, muscle activity of the major leg muscles, heart rate and the Borg scale were measured under different walking conditions including a non-cooperative position control mode to investigate the short-term effects of patient-cooperative versus non-cooperative robot-aided gait training. Results Patient-cooperative robot-aided gait training was tolerated well by all subjects and performed without difficulties. The subjects trained more actively and with more physiological muscle activity than in a non-cooperative position-control mode. One subject showed a significant and relevant increase of gait speed after the therapy, the three remaining subjects did not show significant changes. Conclusions Patient-cooperative robot-aided gait training is feasible in clinical practice and overcomes the main points of criticism against robot-aided gait training: It enables patients to train in an active, variable and more natural way. The limited number of subjects in this pilot trial does not permit valid conclusions on the effect of patient-cooperative robot-aided gait training on walking function. A large, possibly multi-center randomized controlled clinical trial is required to shed more light on this question. PMID:22650320
Waldman, Genna; Yang, Chung-Yong; Ren, Yupeng; Liu, Lin; Guo, Xin; Harvey, Richard L; Roth, Elliot J; Zhang, Li-Qun
2013-01-01
To investigate the effects of controlled passive stretching and active movement training using a portable rehabilitation robot on stroke survivors with ankle and mobility impairment. Twenty-four patients at least 3 months post stroke were assigned to receive 6 week training using the portable robot in a research laboratory (robot group) or an instructed exercise program at home (control group). All patients underwent clinical and biomechanical evaluations in the laboratory at pre-evaluation, post-evaluation, and 6-week follow-up. Subjects in the robot group improved significantly more than that in the control group in reduction in spasticity measured by modified Ashworth scale, mobility by Stroke Rehabilitation Assessment of Movement (STREAM), the balance by Berg balance score, dorsiflexion passive range of motion, dorsiflexion strength, and load bearing on the affected limb during gait after 6-week training. Both groups improved in the STREAM, dorsiflexion active range of motion and dorsiflexor strength after the training, which were retained in the follow-up evaluation. Robot-assisted passive stretching and active movement training is effective in improving motor function and mobility post stroke.
Li, Chong; Bi, Sheng; Zhang, Xuemin; Huo, Jianfei
2017-01-01
Numerous robots have been widely used to deliver rehabilitative training for hemiplegic patients to improve their functional ability. Because of the complexity and diversity of upper limb motion, customization of training patterns is one key factor during upper limb rehabilitation training. Most of the current rehabilitation robots cannot intelligently provide adaptive training parameters, and they have not been widely used in clinical rehabilitation. This article proposes a new end-effector upper limb rehabilitation robot, which is a two-link robotic arm with two active degrees of freedom. This work investigated the kinematics and dynamics of the robot system, the control system, and the realization of different rehabilitation therapies. We also explored the influence of constraint in rehabilitation therapies on interaction force and muscle activation. The deviation of the trajectory of the end effector and the required trajectory was less than 1 mm during the tasks, which demonstrated the movement accuracy of the robot. Besides, results also demonstrated the constraint exerted by the robot provided benefits for hemiplegic patients by changing muscle activation in the way similar to the movement pattern of the healthy subjects, which indicated that the robot can improve the patient's functional ability by training the normal movement pattern. PMID:29065614
Liu, Yali; Li, Chong; Ji, Linhong; Bi, Sheng; Zhang, Xuemin; Huo, Jianfei; Ji, Run
2017-01-01
Numerous robots have been widely used to deliver rehabilitative training for hemiplegic patients to improve their functional ability. Because of the complexity and diversity of upper limb motion, customization of training patterns is one key factor during upper limb rehabilitation training. Most of the current rehabilitation robots cannot intelligently provide adaptive training parameters, and they have not been widely used in clinical rehabilitation. This article proposes a new end-effector upper limb rehabilitation robot, which is a two-link robotic arm with two active degrees of freedom. This work investigated the kinematics and dynamics of the robot system, the control system, and the realization of different rehabilitation therapies. We also explored the influence of constraint in rehabilitation therapies on interaction force and muscle activation. The deviation of the trajectory of the end effector and the required trajectory was less than 1 mm during the tasks, which demonstrated the movement accuracy of the robot. Besides, results also demonstrated the constraint exerted by the robot provided benefits for hemiplegic patients by changing muscle activation in the way similar to the movement pattern of the healthy subjects, which indicated that the robot can improve the patient's functional ability by training the normal movement pattern.
Grosmaire, Anne-Gaëlle; Duret, Christophe
2017-01-01
Repetitive, active movement-based training promotes brain plasticity and motor recovery after stroke. Robotic therapy provides highly repetitive therapy that reduces motor impairment. However, the effect of assist-as-needed algorithms on patient participation and movement quality is not known. To analyze patient participation and motor performance during highly repetitive assist-as-needed upper limb robotic therapy in a retrospective study. Sixteen patients with sub-acute stroke carried out a 16-session upper limb robotic training program combined with usual care. The Fugl-Meyer Assessment (FMA) score was evaluated pre and post training. Robotic assistance parameters and Performance measures were compared within and across sessions. Robotic assistance did not change within-session and decreased between sessions during the training program. Motor performance did not decrease within-session and improved between sessions. Velocity-related assistance parameters improved more quickly than accuracy-related parameters. An assist-as-needed-based upper limb robotic training provided intense and repetitive rehabilitation and promoted patient participation and motor performance, facilitating motor recovery.
Develop a wearable ankle robot for in-bed acute stroke rehabilitation.
Ren, Yupeng; Xu, Tao; Wang, Liang; Yang, Chung Yong; Guo, Xin; Harvey, Richard L; Zhang, Li-Qun
2011-01-01
Movement training is important in motor recovery post stroke and early intervention is critical to stroke rehabilitation. However, acute stroke survivors are actively trained with activities helpful for recovery of mobility in only 13% of the time in the acute phase. Considering the first few months post stroke is critical in stroke recovery (neuroplasticity), there is a strong need for movement therapy and manipulate/mobilize the joints. There is a lack of in-bed robotic rehabilitation in acute stroke. This study seeks to meet the clinic need and deliver intensive passive and active movement therapy using a wearable robot to enhance motor function in acute stroke. Passively, the wearable robot stretches the joint to its extreme positions safely and forcefully. Actively, movement training is conducted and game playing is used to guide and motivate the patient in movement training.
Feys, Peter; Coninx, Karin; Kerkhofs, Lore; De Weyer, Tom; Truyens, Veronik; Maris, Anneleen; Lamers, Ilse
2015-07-23
Despite the functional impact of upper limb dysfunction in multiple sclerosis (MS), effects of intensive exercise programs and specifically robot-supported training have been rarely investigated in persons with advanced MS. To investigate the effects of additional robot-supported upper limb training in persons with MS compared to conventional treatment only. Seventeen persons with MS (pwMS) (median Expanded Disability Status Scale of 8, range 3.5-8.5) were included in a pilot RCT comparing the effects of additional robot-supported training to conventional treatment only. Additional training consisted of 3 weekly sessions of 30 min interacting with the HapticMaster robot within an individualised virtual learning environment (I-TRAVLE). Clinical measures at body function (Hand grip strength, Motricity Index, Fugl-Meyer) and activity (Action Research Arm test, Motor Activity Log) level were administered before and after an intervention period of 8 weeks. The intervention group were also evaluated on robot-mediated movement tasks in three dimensions, providing active range of motion, movement duration and speed and hand-path ratio as indication of movement efficiency in the spatial domain. Non-parametric statistics were applied. PwMS commented favourably on the robot-supported virtual learning environment and reported functional training effects in daily life. Movement tasks in three dimensions, measured with the robot, were performed in less time and for the transporting and reaching movement tasks more efficiently. There were however no significant changes for any clinical measure in neither intervention nor control group although observational analyses of the included cases indicated large improvements on the Fugl-Meyer in persons with more marked upper limb dysfunction. Robot-supported training lead to more efficient movement execution which was however, on group level, not reflected by significant changes on standard clinical tests. Persons with more marked upper limb dysfunction may benefit most from additional robot-supported training, but larger studies are needed. This trial is registered within the registry Clinical Trials GOV ( NCT02257606 ).
Liu, W; Mukherjee, M; Tsaur, Y; Kim, S H; Liu, H; Natarajan, P; Agah, A
2009-01-01
Functional impairment of the upper limb is a major challenge faced by many stroke survivors. The present study aimed at developing a novel sensory-enhanced robot-aided motor training program and testing its feasibility in stroke rehabilitation. A specially designed robot handle was developed as an attachment to the Inmotion2 robotic system. This handle provided sensory stimulation through pins connected to small servo motors inside the handle. Vibration of the pins was activated during motor training once pressure on the handle reached a certain threshold indicating an active motion of the study subject. Nine chronic stroke survivors were randomly assigned to either a sensory-enhanced robot-aided motor training group (SERMT) or robot-aided motor training only group (RMT). All participants underwent a 6-week motor training program, performing target reaching movements with the specialized handle with or without vibration stimulation during training. Motor Status (MS) scores were measured for functional outcome prior to and after training. The results showed significant improvement in the total MS scores after training in both experimental groups. However, MS sub-scores for the shoulder/elbow and the wrist/hand increased significantly only in the SERMT group (p<0.05). Future studies are required to confirm these preliminary findings.
Gandolfi, Marialuisa; Geroin, Christian; Tomelleri, Christopher; Maddalena, Isacco; Kirilova Dimitrova, Eleonora; Picelli, Alessandro; Smania, Nicola; Waldner, Andreas
2017-12-01
So far, the development of robotic devices for the early lower limb mobilization in the sub-acute phase after stroke has received limited attention. To explore the feasibility of a newly robotic-stationary gait training in sub-acute stroke patients. To report the training effects on lower limb function and muscle activation. A pilot study. Rehabilitation ward. Two sub-acute stroke inpatients and ten age-matched healthy controls were enrolled. Healthy controls served as normative data. Patients underwent 10 robot-assisted training sessions (20 minutes, 5 days/week) in alternating stepping movements (500 repetitions/session) on a hospital bed in addition to conventional rehabilitation. Feasibility outcome measures were compliance, physiotherapist time, and responses to self-report questionnaires. Efficacy outcomes were bilateral lower limb muscle activation pattern as measured by surface electromyography (sEMG), Motricity Index (MI), Medical Research Council (MRC) grade, and Ashworth Scale (AS) scores before and after training. No adverse events occurred. No significant differences in sEMG activity between patients and healthy controls were observed. Post-training improvement in MI and MRC scores, but no significant changes in AS scores, were recorded. Post-treatment sEMG analysis of muscle activation patterns showed a significant delay in rectus femoris offset (P=0.02) and prolonged duration of biceps femoris (P=0.04) compared to pretreatment. The robot-assisted training with our device was feasible and safe. It induced physiological muscle activations pattern in both stroke patients and healthy controls. Full-scale studies are needed to explore its potential role in post-stroke recovery. This robotic device may enrich early rehabilitation in subacute stroke patients by inducing physiological muscle activation patterns. Future studies are warranted to evaluate its effects on promoting restorative mechanisms involved in lower limb recovery after stroke.
Zeng, Xiangfeng; Zhu, Guoli; Zhang, Mingming; Xie, Sheng Q
2018-01-01
This review aims to provide a systematical investigation of clinical effectiveness of active training strategies applied in platform-based ankle robots. English-language studies published from Jan 1980 to Aug 2017 were searched from four databases using key words of "Ankle ∗ " AND "Robot ∗ " AND "Effect ∗ OR Improv ∗ OR Increas ∗ ." Following an initial screening, three rounds of discrimination were successively conducted based on the title, the abstract, and the full paper. A total of 21 studies were selected with 311 patients involved; of them, 13 studies applied a single group while another eight studies used different groups for comparison to verify the therapeutic effect. Virtual-reality (VR) game training was applied in 19 studies, while two studies used proprioceptive neuromuscular facilitation (PNF) training. Active training techniques delivered by platform ankle rehabilitation robots have been demonstrated with great potential for clinical applications. Training strategies are mostly combined with one another by considering rehabilitation schemes and motion ability of ankle joints. VR game environment has been commonly used with active ankle training. Bioelectrical signals integrated with VR game training can implement intelligent identification of movement intention and assessment. These further provide the foundation for advanced interactive training strategies that can lead to enhanced training safety and confidence for patients and better treatment efficacy.
Kim, Ha Yeon; Yang, Sung Phil; Park, Gyu Lee; Kim, Eun Joo; You, Joshua Sung Hyun
2016-01-01
Robot-assisted and treadmill-gait training are promising neurorehabilitation techniques, with advantages over conventional gait training, but the neural substrates underpinning locomotor control remain unknown particularly during different gait training modes and speeds. The present optical imaging study compared cortical activities during conventional stepping walking (SW), treadmill walking (TW), and robot-assisted walking (RW) at different speeds. Fourteen healthy subjects (6 women, mean age 30.06, years ± 4.53) completed three walking training modes (SW, TW, and RW) at various speeds (self-selected, 1.5, 2.0, 2.5, and 3.0 km/h). A functional near-infrared spectroscopy (fNIRS) system determined cerebral hemodynamic changes associated with cortical locomotor network areas in the primary sensorimotor cortex (SMC), premotor cortex (PMC), supplementary motor area (SMA), prefrontal cortex (PFC), and sensory association cortex (SAC). There was increased cortical activation in the SMC, PMC, and SMA during different walking training modes. More global locomotor network activation was observed during RW than TW or SW. As walking speed increased, multiple locomotor network activations were observed, and increased activation power spectrum. This is the first empirical evidence highlighting the neural substrates mediating dynamic locomotion for different gait training modes and speeds. Fast, robot-assisted gait training best facilitated cortical activation associated with locomotor control.
Task-oriented rehabilitation robotics.
Schweighofer, Nicolas; Choi, Younggeun; Winstein, Carolee; Gordon, James
2012-11-01
Task-oriented training is emerging as the dominant and most effective approach to motor rehabilitation of upper extremity function after stroke. Here, the authors propose that the task-oriented training framework provides an evidence-based blueprint for the design of task-oriented robots for the rehabilitation of upper extremity function in the form of three design principles: skill acquisition of functional tasks, active participation training, and individualized adaptive training. The previous robotic systems that incorporate elements of task-oriented trainings are then reviewed. Finally, the authors critically analyze their own attempt to design and test the feasibility of a TOR robot, ADAPT (Adaptive and Automatic Presentation of Tasks), which incorporates the three design principles. Because of its task-oriented training-based design, ADAPT departs from most other current rehabilitation robotic systems: it presents realistic functional tasks in which the task goal is constantly adapted, so that the individual actively performs doable but challenging tasks without physical assistance. To maximize efficacy for a large clinical population, the authors propose that future task-oriented robots need to incorporate yet-to-be developed adaptive task presentation algorithms that emphasize acquisition of fine motor coordination skills while minimizing compensatory movements.
Outcomes from the Delphi process of the Thoracic Robotic Curriculum Development Committee.
Veronesi, Giulia; Dorn, Patrick; Dunning, Joel; Cardillo, Giuseppe; Schmid, Ralph A; Collins, Justin; Baste, Jean-Marc; Limmer, Stefan; Shahin, Ghada M M; Egberts, Jan-Hendrik; Pardolesi, Alessandro; Meacci, Elisa; Stamenkovic, Sasha; Casali, Gianluca; Rueckert, Jens C; Taurchini, Mauro; Santelmo, Nicola; Melfi, Franca; Toker, Alper
2018-06-01
As the adoption of robotic procedures becomes more widespread, additional risk related to the learning curve can be expected. This article reports the results of a Delphi process to define procedures to optimize robotic training of thoracic surgeons and to promote safe performance of established robotic interventions as, for example, lung cancer and thymoma surgery. In June 2016, a working panel was spontaneously created by members of the European Society of Thoracic Surgeons (ESTS) and European Association for Cardio-Thoracic Surgery (EACTS) with a specialist interest in robotic thoracic surgery and/or surgical training. An e-consensus-finding exercise using the Delphi methodology was applied requiring 80% agreement to reach consensus on each question. Repeated iterations of anonymous voting continued over 3 rounds. Agreement was reached on many points: a standardized robotic training curriculum for robotic thoracic surgery should be divided into clearly defined sections as a staged learning pathway; the basic robotic curriculum should include a baseline evaluation, an e-learning module, a simulation-based training (including virtual reality simulation, Dry lab and Wet lab) and a robotic theatre (bedside) observation. Advanced robotic training should include e-learning on index procedures (right upper lobe) with video demonstration, access to video library of robotic procedures, simulation training, modular console training to index procedure, transition to full-procedure training with a proctor and final evaluation of the submitted video to certified independent examiners. Agreement was reached on a large number of questions to optimize and standardize training and education of thoracic surgeons in robotic activity. The production of the content of the learning material is ongoing.
General surgery residents' perception of robot-assisted procedures during surgical training.
Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael
2015-01-01
With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p < 0.001). Overall, 60% of residents indicated that they received no prior education or training before their first robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases would replace conventional laparoscopic surgery in the future. This study illustrates that although the most residents have a robot at their institution and have participated in robotic surgery cases, very few residents received formal training before participating in a robotic case. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H
2017-05-01
While body weight support (BWS) intonation is vital during conventional gait training of neurologically challenged subjects, it is important to evaluate its effect during robot assisted gait training. In the present research we have studied the effect of BWS intonation on muscle activities during robotic gait training using dynamic simulations. Two dimensional (2-D) musculoskeletal model of human gait was developed conjointly with another 2-D model of a robotic orthosis capable of actuating hip, knee and ankle joints simultaneously. The musculoskeletal model consists of eight major muscle groups namely; soleus (SOL), gastrocnemius (GAS), tibialis anterior (TA), hamstrings (HAM), vasti (VAS), gluteus maximus (GLU), uniarticular hip flexors (iliopsoas, IP), and Rectus Femoris (RF). BWS was provided at levels of 0, 20, 40 and 60% during the simulations. In order to obtain a feasible set of muscle activities during subsequent gait cycles, an inverse dynamics algorithm along with a quadratic minimization algorithm was implemented. The dynamic parameters of the robot assisted human gait such as joint angle trajectories, ground contact force (GCF), human limb joint torques and robot induced torques at different levels of BWS were derived. The patterns of muscle activities at variable BWS were derived and analysed. For most part of the gait cycle (GC) the muscle activation patterns are quite similar for all levels of BWS as is apparent from the mean of muscle activities for the complete GC. Effect of BWS variation during robot assisted gait on muscle activities was studied by developing dynamic simulation. It is expected that the proposed dynamic simulation approach will provide important inferences and information about the muscle function variations consequent upon a change in BWS during robot assisted gait. This information shall be quite important while investigating the influence of BWS intonation on neuromuscular parameters of interest during robotic gait training.
2013-01-01
Background Robot-assisted gait training and treadmill training can complement conventional physical therapy in children with neuro-orthopedic movement disorders. The aim of this study was to investigate surface electromyography (sEMG) activity patterns during robot-assisted gait training (with and without motivating instructions from a therapist) and unassisted treadmill walking and to compare these with physiological sEMG patterns. Methods Nine children with motor impairments and eight healthy children walked in various conditions: (a) on a treadmill in the driven gait orthosis Lokomat®, (b) same condition, with additional motivational instructions from a therapist, and (c) on the treadmill without assistance. sEMG recordings were made of the tibialis anterior, gastrocnemius lateralis, vastus medialis, and biceps femoris muscles. Differences in sEMG amplitudes between the three conditions were analyzed for the duration of stance and swing phase (for each group and muscle separately) using non-parametric tests. Spearman’s correlation coefficients illustrated similarity of muscle activation patterns between conditions, between groups, and with published reference trajectories. Results The relative duration of stance and swing phase differed between patients and controls, and between driven gait orthosis conditions and treadmill walking. While sEMG amplitudes were higher when being encouraged by a therapist compared to robot-assisted gait training without instructions (0.008 ≤ p-value ≤ 0.015), muscle activation patterns were highly comparable (0.648 ≤ Spearman correlation coefficients ≤ 0.969). In general, comparisons of the sEMG patterns with published reference data of over-ground walking revealed that walking in the driven gait orthosis could induce more physiological muscle activation patterns compared to unsupported treadmill walking. Conclusions Our results suggest that robotic-assisted gait training with therapeutic encouragement could appropriately increase muscle activity. Robotic-assisted gait training in general could induce physiological muscle activation patterns, which might indicate that this training exploits restorative rather than compensatory mechanisms. PMID:23867005
Portable and Reconfigurable Wrist Robot Improves Hand Function for Post-Stroke Subjects.
Khor, Kang Xiang; Chin, Patrick Jun Hua; Yeong, Che Fai; Su, Eileen Lee Ming; Narayanan, Aqilah Leela T; Abdul Rahman, Hisyam; Khan, Qamer Iqbal
2017-10-01
Rehabilitation robots have become increasingly popular for stroke rehabilitation. However, the high cost of robots hampers their implementation on a large scale. This paper implements the concept of a modular and reconfigurable robot, reducing its cost and size by adopting different therapeutic end effectors for different training movements using a single robot. The challenge is to increase the robot's portability and identify appropriate kinds of modular tools and configurations. Because literature on the effectiveness of this kind of rehabilitation robot is still scarce, this paper presents the design of a portable and reconfigurable rehabilitation robot and describes its use with a group of post-stroke patients for wrist and forearm training. Seven stroke subjects received training using a reconfigurable robot for 30 sessions, lasting 30 min per session. Post-training, statistical analysis showed significant improvement of 3.29 points (16.20%, p = 0.027) on the Fugl-Meyer assessment scale for forearm and wrist components. Significant improvement of active range of motion was detected in both pronation-supination (75.59%, p = 0.018) and wrist flexion-extension (56.12%, p = 0.018) after the training. These preliminary results demonstrate that the developed reconfigurable robot could improve subjects' wrist and forearm movement.
Development of wrist rehabilitation robot and interface system.
Yamamoto, Ikuo; Matsui, Miki; Inagawa, Naohiro; Hachisuka, Kenji; Wada, Futoshi; Hachisuka, Akiko; Saeki, Satoru
2015-01-01
The authors have developed a practical wrist rehabilitation robot for hemiplegic patients. It consists of a mechanical rotation unit, sensor, grip, and computer system. A myoelectric sensor is used to monitor the extensor carpi radialis longus/brevis muscle and flexor carpi radialis muscle activity during training. The training robot can provoke training through myoelectric sensors, a biological signal detector and processor in advance, so that patients can undergo effective training of extention and flexion in an excited condition. In addition, both-wrist system has been developed for mirror effect training, which is the most effective function of the system, so that autonomous training using both wrists is possible. Furthermore, a user-friendly screen interface with easily recognizable touch panels has been developed to give effective training for patients. The developed robot is small size and easy to carry. The developed aspiring interface system is effective to motivate the training of patients. The effectiveness of the robot system has been verified in hospital trails.
NASA Astrophysics Data System (ADS)
Cao, Enguo; Inoue, Yoshio; Liu, Tao; Shibata, Kyoko
In many countries in which the phenomenon of population aging is being experienced, motor function recovery activities have aroused much interest. In this paper, a sit-to-stand rehabilitation robot utilizing a double-rope system was developed, and the performance of the robot was evaluated by analyzing the dynamic parameters of human lower limbs. For the robot control program, an impedance control method with a training game was developed to increase the effectiveness and frequency of rehabilitation activities, and a calculation method was developed for evaluating the joint moments of hip, knee, and ankle. Test experiments were designed, and four subjects were requested to stand up from a chair with assistance from the rehabilitation robot. In the experiments, body segment rotational angles, trunk movement trajectories, rope tensile forces, ground reaction forces (GRF) and centers of pressure (COP) were measured by sensors, and the moments of ankle, knee and hip joint were real-time calculated using the sensor-measured data. The experiment results showed that the sit-to-stand rehabilitation robot with impedance control method could maintain the comfortable training postures of users, decrease the moments of limb joints, and enhance training effectiveness. Furthermore, the game control method could encourage collaboration between the brain and limbs, and allow for an increase in the frequency and intensity of rehabilitation activities.
Lemmens, Ryanne J. M.; Timmermans, Annick A. A.; Janssen-Potten, Yvonne J. M.; Pulles, Sanne A. N. T. D.; Geers, Richard P. J.; Bakx, Wilbert G. M.; Smeets, Rob J. E. M.; Seelen, Henk A. M.
2014-01-01
Purpose This study aims to assess the extent to which accelerometers can be used to determine the effect of robot-supported task-oriented arm-hand training, relative to task-oriented arm-hand training alone, on the actual amount of arm-hand use of chronic stroke patients in their home situation. Methods This single-blind randomized controlled trial included 16 chronic stroke patients, randomly allocated using blocked randomization (n = 2) to receive task-oriented robot-supported arm-hand training or task-oriented (unsupported) arm-hand training. Training lasted 8 weeks, 4 times/week, 2×30 min/day using the (T-)TOAT ((Technology-supported)-Task-Oriented-Arm-Training) method. The actual amount of arm-hand use, was assessed at baseline, after 8 weeks training and 6 months after training cessation. Duration of use and intensity of use of the affected arm-hand during unimanual and bimanual activities were calculated. Results Duration and intensity of use of the affected arm-hand did not change significantly during and after training, with or without robot-support (i.e. duration of use of unimanual use of the affected arm-hand: median difference of −0.17% in the robot-group and −0.08% in the control group between baseline and after training cessation; intensity of the affected arm-hand: median difference of 3.95% in the robot-group and 3.32% in the control group between baseline and after training cessation). No significant between-group differences were found. Conclusions Accelerometer data did not show significant changes in actual amount of arm-hand use after task-oriented training, with or without robot-support. Next to the amount of use, discrimination between activities performed and information about quality of use of the affected arm-hand are essential to determine actual arm-hand performance. Trial Registration Controlled-trials.com ISRCTN82787126 PMID:24823925
Task-specific ankle robotics gait training after stroke: a randomized pilot study.
Forrester, Larry W; Roy, Anindo; Hafer-Macko, Charlene; Krebs, Hermano I; Macko, Richard F
2016-06-02
An unsettled question in the use of robotics for post-stroke gait rehabilitation is whether task-specific locomotor training is more effective than targeting individual joint impairments to improve walking function. The paretic ankle is implicated in gait instability and fall risk, but is difficult to therapeutically isolate and refractory to recovery. We hypothesize that in chronic stroke, treadmill-integrated ankle robotics training is more effective to improve gait function than robotics focused on paretic ankle impairments. Participants with chronic hemiparetic gait were randomized to either six weeks of treadmill-integrated ankle robotics (n = 14) or dose-matched seated ankle robotics (n = 12) videogame training. Selected gait measures were collected at baseline, post-training, and six-week retention. Friedman, and Wilcoxon Sign Rank and Fisher's exact tests evaluated within and between group differences across time, respectively. Six weeks post-training, treadmill robotics proved more effective than seated robotics to increase walking velocity, paretic single support, paretic push-off impulse, and active dorsiflexion range of motion. Treadmill robotics durably improved gait dorsiflexion swing angle leading 6/7 initially requiring ankle braces to self-discarded them, while their unassisted paretic heel-first contacts increased from 44 % to 99.6 %, versus no change in assistive device usage (0/9) following seated robotics. Treadmill-integrated, but not seated ankle robotics training, durably improves gait biomechanics, reversing foot drop, restoring walking propulsion, and establishing safer foot landing in chronic stroke that may reduce reliance on assistive devices. These findings support a task-specific approach integrating adaptive ankle robotics with locomotor training to optimize mobility recovery. NCT01337960. https://clinicaltrials.gov/ct2/show/NCT01337960?term=NCT01337960&rank=1.
Learning a locomotor task: with or without errors?
Marchal-Crespo, Laura; Schneider, Jasmin; Jaeger, Lukas; Riener, Robert
2014-03-04
Robotic haptic guidance is the most commonly used robotic training strategy to reduce performance errors while training. However, research on motor learning has emphasized that errors are a fundamental neural signal that drive motor adaptation. Thus, researchers have proposed robotic therapy algorithms that amplify movement errors rather than decrease them. However, to date, no study has analyzed with precision which training strategy is the most appropriate to learn an especially simple task. In this study, the impact of robotic training strategies that amplify or reduce errors on muscle activation and motor learning of a simple locomotor task was investigated in twenty two healthy subjects. The experiment was conducted with the MAgnetic Resonance COmpatible Stepper (MARCOS) a special robotic device developed for investigations in the MR scanner. The robot moved the dominant leg passively and the subject was requested to actively synchronize the non-dominant leg to achieve an alternating stepping-like movement. Learning with four different training strategies that reduce or amplify errors was evaluated: (i) Haptic guidance: errors were eliminated by passively moving the limbs, (ii) No guidance: no robot disturbances were presented, (iii) Error amplification: existing errors were amplified with repulsive forces, (iv) Noise disturbance: errors were evoked intentionally with a randomly-varying force disturbance on top of the no guidance strategy. Additionally, the activation of four lower limb muscles was measured by the means of surface electromyography (EMG). Strategies that reduce or do not amplify errors limit muscle activation during training and result in poor learning gains. Adding random disturbing forces during training seems to increase attention, and therefore improve motor learning. Error amplification seems to be the most suitable strategy for initially less skilled subjects, perhaps because subjects could better detect their errors and correct them. Error strategies have a great potential to evoke higher muscle activation and provoke better motor learning of simple tasks. Neuroimaging evaluation of brain regions involved in learning can provide valuable information on observed behavioral outcomes related to learning processes. The impacts of these strategies on neurological patients need further investigations.
Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit
2015-03-01
An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the muscle co-contraction on finger and elbow joints. The upper limb functions were improved on chronic stroke patients after the pilot study of 20-session hand training with the combined assistance from the EMG-driven NMES-robot. The muscle spasticity on finger and elbow joints was reduced after the training.
Basteris, Angelo; Nijenhuis, Sharon M; Stienen, Arno H A; Buurke, Jaap H; Prange, Gerdienke B; Amirabdollahian, Farshid
2014-07-10
Robot-mediated post-stroke therapy for the upper-extremity dates back to the 1990s. Since then, a number of robotic devices have become commercially available. There is clear evidence that robotic interventions improve upper limb motor scores and strength, but these improvements are often not transferred to performance of activities of daily living. We wish to better understand why. Our systematic review of 74 papers focuses on the targeted stage of recovery, the part of the limb trained, the different modalities used, and the effectiveness of each. The review shows that most of the studies so far focus on training of the proximal arm for chronic stroke patients. About the training modalities, studies typically refer to active, active-assisted and passive interaction. Robot-therapy in active assisted mode was associated with consistent improvements in arm function. More specifically, the use of HRI features stressing active contribution by the patient, such as EMG-modulated forces or a pushing force in combination with spring-damper guidance, may be beneficial.Our work also highlights that current literature frequently lacks information regarding the mechanism about the physical human-robot interaction (HRI). It is often unclear how the different modalities are implemented by different research groups (using different robots and platforms). In order to have a better and more reliable evidence of usefulness for these technologies, it is recommended that the HRI is better described and documented so that work of various teams can be considered in the same group and categories, allowing to infer for more suitable approaches. We propose a framework for categorisation of HRI modalities and features that will allow comparing their therapeutic benefits.
2014-01-01
Robot-mediated post-stroke therapy for the upper-extremity dates back to the 1990s. Since then, a number of robotic devices have become commercially available. There is clear evidence that robotic interventions improve upper limb motor scores and strength, but these improvements are often not transferred to performance of activities of daily living. We wish to better understand why. Our systematic review of 74 papers focuses on the targeted stage of recovery, the part of the limb trained, the different modalities used, and the effectiveness of each. The review shows that most of the studies so far focus on training of the proximal arm for chronic stroke patients. About the training modalities, studies typically refer to active, active-assisted and passive interaction. Robot-therapy in active assisted mode was associated with consistent improvements in arm function. More specifically, the use of HRI features stressing active contribution by the patient, such as EMG-modulated forces or a pushing force in combination with spring-damper guidance, may be beneficial. Our work also highlights that current literature frequently lacks information regarding the mechanism about the physical human-robot interaction (HRI). It is often unclear how the different modalities are implemented by different research groups (using different robots and platforms). In order to have a better and more reliable evidence of usefulness for these technologies, it is recommended that the HRI is better described and documented so that work of various teams can be considered in the same group and categories, allowing to infer for more suitable approaches. We propose a framework for categorisation of HRI modalities and features that will allow comparing their therapeutic benefits. PMID:25012864
Predicting space telerobotic operator training performance from human spatial ability assessment
NASA Astrophysics Data System (ADS)
Liu, Andrew M.; Oman, Charles M.; Galvan, Raquel; Natapoff, Alan
2013-11-01
Our goal was to determine whether existing tests of spatial ability can predict an astronaut's qualification test performance after robotic training. Because training astronauts to be qualified robotics operators is so long and expensive, NASA is interested in tools that can predict robotics performance before training begins. Currently, the Astronaut Office does not have a validated tool to predict robotics ability as part of its astronaut selection or training process. Commonly used tests of human spatial ability may provide such a tool to predict robotics ability. We tested the spatial ability of 50 active astronauts who had completed at least one robotics training course, then used logistic regression models to analyze the correlation between spatial ability test scores and the astronauts' performance in their evaluation test at the end of the training course. The fit of the logistic function to our data is statistically significant for several spatial tests. However, the prediction performance of the logistic model depends on the criterion threshold assumed. To clarify the critical selection issues, we show how the probability of correct classification vs. misclassification varies as a function of the mental rotation test criterion level. Since the costs of misclassification are low, the logistic models of spatial ability and robotic performance are reliable enough only to be used to customize regular and remedial training. We suggest several changes in tracking performance throughout robotics training that could improve the range and reliability of predictive models.
Chisholm, Amanda E; Alamro, Raed A; Williams, Alison M M; Lam, Tania
2017-04-11
Robotic overground gait training devices, such as the Ekso, require users to actively participate in triggering steps through weight-shifting movements. It remains unknown how much the trunk muscles are activated during these movements, and if it is possible to transfer training effects to seated balance control. This study was conducted to compare the activity of postural control muscles of the trunk during overground (Ekso) vs. treadmill-based (Lokomat) robotic gait training, and evaluate changes in seated balance control in people with high-thoracic motor-complete spinal cord injury (SCI). Three individuals with motor-complete SCI from C7-T4, assumed to have no voluntary motor function below the chest, underwent robotic gait training. The participants were randomly assigned to Ekso-Lokomat-Ekso or Lokomat-Ekso-Lokomat for 10 sessions within each intervention phase for a total of 30 sessions. We evaluated static and dynamic balance control through analysis of center of pressure (COP) movements after each intervention phase. Surface electromyography was used to compare activity of the abdominal and erector spinae muscles during Ekso and Lokomat walking. We observed improved postural stability after training with Ekso compared to Lokomat during static balance tasks, indicated by reduced COP root mean square distance and ellipse area. In addition, Ekso training increased total distance of COP movements during a dynamic balance task. The trunk muscles showed increased activation during Ekso overground walking compared to Lokomat walking. Our findings suggest that the Ekso actively recruits trunk muscles through postural control mechanisms, which may lead to improved balance during sitting. Developing effective training strategies to reactivate the trunk muscles is important to facilitate independence during seated balance activity in people with SCI.
Tacchino, Giulia; Gandolla, Marta; Coelli, Stefania; Barbieri, Riccardo; Pedrocchi, Alessandra; Bianchi, Anna M
2017-06-01
Two key ingredients of a successful neuro-rehabilitative intervention have been identified as intensive and repetitive training and subject's active participation, which can be coupled in an active robot-assisted training. To exploit these two elements, we recorded electroencephalography, electromyography and kinematics signals from nine healthy subjects performing a 2×2 factorial design protocol, with subject's volitional intention and robotic glove assistance as factors. We quantitatively evaluated primary sensorimotor, premotor and supplementary motor areas activation during movement execution by computing event-related desynchronization (ERD) patterns associated to mu and beta rhythms. ERD patterns showed a similar behavior for all investigated regions: statistically significant ERDs began earlier in conditions requiring subject's volitional contribution; ERDs were prolonged towards the end of movement in conditions in which the robotic assistance was present. Our study suggests that the combination between subject volitional contribution and movement assistance provided by the robotic device (i.e., active robot-assisted modality) is able to provide early brain activation (i.e., earlier ERD) associated with stronger proprioceptive feedback (i.e., longer ERD). This finding might be particularly important for neurological patients, where movement cannot be completed autonomously and passive/active robot-assisted modalities are the only possibilities of execution.
Developing a Wearable Ankle Rehabilitation Robotic Device for in-Bed Acute Stroke Rehabilitation.
Ren, Yupeng; Wu, Yi-Ning; Yang, Chung-Yong; Xu, Tao; Harvey, Richard L; Zhang, Li-Qun
2017-06-01
Ankle movement training is important in motor recovery post stroke and early intervention is critical to stroke rehabilitation. However, acute stroke survivors receive motor rehabilitation in only a small fraction of time, partly due to the lack of effective devices and protocols suitable for early in-bed rehabilitation. Considering the first few months post stroke is critical in stroke recovery, there is a strong need to start motor rehabilitation early, mobilize the ankle, and conduct movement therapy. This study seeks to address the need and deliver intensive passive and active movement training in acute stroke using a wearable ankle robotic device. Isometric torque generation mode under real-time feedback is used to guide patients in motor relearning. In the passive stretching mode, the wearable robotic device stretches the ankle throughout its range of motion to the extreme dorsiflexion forcefully and safely. In the active movement training mode, a patient is guided and motivated to actively participate in movement training through game playing. Clinical testing of the wearable robotic device on 10 acute stroke survivors over 12 sessions of feedback-facilitated isometric torque generation, and passive and active movement training indicated that the early in-bed rehabilitation could have facilitated neuroplasticity and helped improve motor control ability.
Timmermans, Annick A A; Lemmens, Ryanne J M; Monfrance, Maurice; Geers, Richard P J; Bakx, Wilbert; Smeets, Rob J E M; Seelen, Henk A M
2014-03-31
Over fifty percent of stroke patients experience chronic arm hand performance problems, compromising independence in daily life activities and quality of life. Task-oriented training may improve arm hand performance after stroke, whereby augmented therapy may lead to a better treatment outcome. Technology-supported training holds opportunities for increasing training intensity. However, the effects of robot-supported task-oriented training with real life objects in stroke patients are not known to date. The aim of the present study was to investigate the effectiveness and added value of the Haptic Master robot combined with task-oriented arm hand training in chronic stroke patients. In a single-blind randomized controlled trial, 22 chronic stroke patients were randomly allocated to receive either task-oriented robot-assisted arm-hand training (experimental group) or task-oriented non-robotic arm-hand training (control group). For training, the T-TOAT (Technology-supported Task-Oriented Arm Training) method was applied. Training was provided during 8 weeks, 4 times/week, 2 × 30 min/day. A significant improvement after training on the Action Research Arm Test (ARAT) was demonstrated in the experimental group (p = 0.008). Results were maintained until 6 months after cessation of the training. On the perceived performance measure (Motor Activity Log (MAL)), both, the experimental and control group improved significantly after training (control group p = 0.008; experimental group p = 0.013). The improvements on MAL in both groups were maintained until 6 months after cessation of the training. With regard to quality of life, only in the control group a significant improvement after training was found (EuroQol-5D p = 0.015, SF-36 physical p = 0.01). However, the improvement on SF-36 in the control group was not maintained (p = 0.012). No between-group differences could be demonstrated on any of the outcome measures. Arm hand performance improved in chronic stroke patients, after eight weeks of task oriented training. The use of a Haptic Master robot in support of task-oriented arm training did not show additional value over the video-instructed task-oriented exercises in highly functional stroke patients. Current Controlled Trials ISRCTN82787126.
Robot-guided ankle sensorimotor rehabilitation of patients with multiple sclerosis.
Lee, Yunju; Chen, Kai; Ren, Yupeng; Son, Jongsang; Cohen, Bruce A; Sliwa, James A; Zhang, Li-Qun
2017-01-01
People with multiple sclerosis (MS) often develop symptoms including muscle weakness, spasticity, imbalance, and sensory loss in the lower limbs, especially at the ankle, which result in impaired balance and locomotion and increased risk of falls. Rehabilitation strategies that improve ankle function may improve mobility and safety of ambulation in patients with MS. This pilot study investigated effectiveness of a robot-guided ankle passive-active movement training in reducing motor and sensory impairments and improving balance and gait functions. Seven patients with MS participated in combined passive stretching and active movement training using an ankle rehabilitation robot. Six of the patients finished robotic training 3 sessions per week over 6 weeks for a total of 18 sessions. Biomechanical and clinical outcome evaluations were done before and after the 6-week treatment, and at a follow-up six weeks afterwards. After six-week ankle sensorimotor training, there were increases in active range of motion in dorsiflexion, dorsiflexor and plantar flexor muscle strength, and balance and locomotion (p<0.05). Proprioception acuity showed a trend of improvement. Improvements in four biomechanical outcome measures and two of the clinical outcome measures were maintained at the 6-week follow-up. The study showed the six-week training duration was appropriate to see improvement of range of motion and strength for MS patients with ankle impairment. Robot-guided ankle training is potentially a useful therapeutic intervention to improve mobility in patients with MS. Copyright © 2016 Elsevier B.V. All rights reserved.
Fleerkotte, Bertine M; Koopman, Bram; Buurke, Jaap H; van Asseldonk, Edwin H F; van der Kooij, Herman; Rietman, Johan S
2014-03-04
There is increasing interest in the use of robotic gait-training devices in walking rehabilitation of incomplete spinal cord injured (iSCI) individuals. These devices provide promising opportunities to increase the intensity of training and reduce physical demands on therapists. Despite these potential benefits, robotic gait-training devices have not yet demonstrated clear advantages over conventional gait-training approaches, in terms of functional outcomes. This might be due to the reduced active participation and step-to-step variability in most robotic gait-training strategies, when compared to manually assisted therapy. Impedance-controlled devices can increase active participation and step-to-step variability. The aim of this study was to assess the effect of impedance-controlled robotic gait training on walking ability and quality in chronic iSCI individuals. A group of 10 individuals with chronic iSCI participated in an explorative clinical trial. Participants trained three times a week for eight weeks using an impedance-controlled robotic gait trainer (LOPES: LOwer extremity Powered ExoSkeleton). Primary outcomes were the 10-meter walking test (10 MWT), the Walking Index for Spinal Cord Injury (WISCI II), the six-meter walking test (6 MWT), the Timed Up and Go test (TUG) and the Lower Extremity Motor Scores (LEMS). Secondary outcomes were spatiotemporal and kinematics measures. All participants were tested before, during, and after training and at 8 weeks follow-up. Participants experienced significant improvements in walking speed (0.06 m/s, p = 0.008), distance (29 m, p = 0.005), TUG (3.4 s, p = 0.012), LEMS (3.4, p = 0.017) and WISCI after eight weeks of training with LOPES. At the eight-week follow-up, participants retained the improvements measured at the end of the training period. Significant improvements were also found in spatiotemporal measures and hip range of motion. Robotic gait training using an impedance-controlled robot is feasible in gait rehabilitation of chronic iSCI individuals. It leads to improvements in walking ability, muscle strength, and quality of walking. Improvements observed at the end of the training period persisted at the eight-week follow-up. Slower walkers benefit the most from the training protocol and achieve the greatest relative improvement in speed and walking distance.
2014-01-01
Background There is increasing interest in the use of robotic gait-training devices in walking rehabilitation of incomplete spinal cord injured (iSCI) individuals. These devices provide promising opportunities to increase the intensity of training and reduce physical demands on therapists. Despite these potential benefits, robotic gait-training devices have not yet demonstrated clear advantages over conventional gait-training approaches, in terms of functional outcomes. This might be due to the reduced active participation and step-to-step variability in most robotic gait-training strategies, when compared to manually assisted therapy. Impedance-controlled devices can increase active participation and step-to-step variability. The aim of this study was to assess the effect of impedance-controlled robotic gait training on walking ability and quality in chronic iSCI individuals. Methods A group of 10 individuals with chronic iSCI participated in an explorative clinical trial. Participants trained three times a week for eight weeks using an impedance-controlled robotic gait trainer (LOPES: LOwer extremity Powered ExoSkeleton). Primary outcomes were the 10-meter walking test (10MWT), the Walking Index for Spinal Cord Injury (WISCI II), the six-meter walking test (6MWT), the Timed Up and Go test (TUG) and the Lower Extremity Motor Scores (LEMS). Secondary outcomes were spatiotemporal and kinematics measures. All participants were tested before, during, and after training and at 8 weeks follow-up. Results Participants experienced significant improvements in walking speed (0.06 m/s, p = 0.008), distance (29 m, p = 0.005), TUG (3.4 s, p = 0.012), LEMS (3.4, p = 0.017) and WISCI after eight weeks of training with LOPES. At the eight-week follow-up, participants retained the improvements measured at the end of the training period. Significant improvements were also found in spatiotemporal measures and hip range of motion. Conclusion Robotic gait training using an impedance-controlled robot is feasible in gait rehabilitation of chronic iSCI individuals. It leads to improvements in walking ability, muscle strength, and quality of walking. Improvements observed at the end of the training period persisted at the eight-week follow-up. Slower walkers benefit the most from the training protocol and achieve the greatest relative improvement in speed and walking distance. PMID:24594284
Yeung, Ling-Fung; Ockenfeld, Corinna; Pang, Man-Kit; Wai, Hon-Wah; Soo, Oi-Yan; Li, Sheung-Wai; Tong, Kai-Yu
2018-06-19
Robot-assisted ankle-foot-orthosis (AFO) can provide immediate powered ankle assistance in post-stroke gait training. Our research team has developed a novel lightweight portable robot-assisted AFO which is capable of detecting walking intentions using sensor feedback of wearer's gait pattern. This study aims to investigate the therapeutic effects of robot-assisted gait training with ankle dorsiflexion assistance. This was a double-blinded randomized controlled trial. Nineteen chronic stroke patients with motor impairment at ankle participated in 20-session robot-assisted gait training for about five weeks, with 30-min over-ground walking and stair ambulation practices. Robot-assisted AFO either provided active powered ankle assistance during swing phase in Robotic Group (n = 9), or torque impedance at ankle joint as passive AFO in Sham Group (n = 10). Functional assessments were performed before and after the 20-session gait training with 3-month Follow-up. Primary outcome measure was gait independency assessed by Functional Ambulatory Category (FAC). Secondary outcome measures were clinical scores including Fugl-Meyer Assessment (FMA), Modified Ashworth Scale (MAS), Berg Balance Scale (BBS), Timed 10-Meter Walk Test (10MWT), Six-minute Walk Test (SMWT), supplemented by gait analysis. All outcome measures were performed in unassisted gait after patients had taken off the robot-assisted AFO. Repeated-measures analysis of covariance was conducted to test the group differences referenced to clinical scores before training. After 20-session robot-assisted gait training with ankle dorsiflexion assistance, the active ankle assistance in Robotic Group induced changes in gait pattern with improved gait independency (all patients FAC ≥ 5 post-training and 3-month follow-up), motor recovery, walking speed, and greater confidence in affected side loading response (vertical ground reaction force + 1.49 N/kg, peak braking force + 0.24 N/kg) with heel strike instead of flat foot touch-down at initial contact (foot tilting + 1.91°). Sham Group reported reduction in affected leg range of motion (ankle dorsiflexion - 2.36° and knee flexion - 8.48°) during swing. Robot-assisted gait training with ankle dorsiflexion assistance could improve gait independency and help stroke patients developing confidence in weight acceptance, but future development of robot-assisted AFO should consider more lightweight and custom-fit design. ClinicalTrials.gov NCT02471248 . Registered 15 June 2015 retrospectively registered.
Robotic Technologies and Rehabilitation: New Tools for Stroke Patients' Therapy
Poli, Patrizia; Morone, Giovanni; Rosati, Giulio; Masiero, Stefano
2013-01-01
Introduction. The role of robotics in poststroke patients' rehabilitation has been investigated intensively. This paper presents the state-of-the-art and the possible future role of robotics in poststroke rehabilitation, for both upper and lower limbs. Materials and Methods. We performed a comprehensive search of PubMed, Cochrane, and PeDRO databases using as keywords “robot AND stroke AND rehabilitation.” Results and Discussion. In upper limb robotic rehabilitation, training seems to improve arm function in activities of daily living. In addition, electromechanical gait training after stroke seems to be effective. It is still unclear whether robot-assisted arm training may improve muscle strength, and which electromechanical gait-training device may be the most effective for walking training implementation. Conclusions. In the field of robotic technologies for stroke patients' rehabilitation we identified currently relevant growing points and areas timely for developing research. Among the growing points there is the development of new easily transportable, wearable devices that could improve rehabilitation also after discharge, in an outpatient or home-based setting. For developing research, efforts are being made to establish the ideal type of treatment, the length and amount of training protocol, and the patient's characteristics to be successfully enrolled to this treatment. PMID:24350244
Fluet, Gerard G; Merians, Alma S; Qiu, Qinyin; Saleh, Soha; Ruano, Viviana; Delmonico, Andrea R; Adamovich, Sergei V
2014-09-01
A majority of studies examining repetitive task practice facilitated by robots for the treatment of upper extremity paresis utilize standardized protocols applied to large groups. This study will describe a virtually simulated, robot-based intervention customized to match the goals and clinical presentation of a gentleman with upper extremity hemiparesis secondary to stroke. MP, the subject of this case, is an 85-year-old man with left hemiparesis secondary to an intracerebral hemorrhage 5 years prior to examination. Outcomes were measured before and after a 1-month period of home therapy and after a 1-month virtually simulated, robotic intervention. The intervention was designed to address specific impairments identified during his PT examination. When necessary, activities were modified based on MP's response to his first week of treatment. MP's home training program produced a 3-s decline in Wolf Motor Function Test (WMFT) time and a 5-s improvement in Jebsen Test of Hand Function (JTHF) time. He demonstrated an additional 35-s improvement in JTHF and an additional 44-s improvement in WMFT subsequent to the robotic training intervention. A 24-h activity measurement and the Hand and Activities of Daily Living scales of the Stroke Impact Scale improved following the robotic intervention. Based on his responses to training we feel that we have established that a customized program of virtually simulated, robotically facilitated rehabilitation was feasible and resulted in larger improvements than an intensive home training program in several measurements of upper extremity function in our patient with chronic hemiparesis.
Hu, Xiaoling; Tong, K Y; Li, R; Chen, M; Xue, J J; Ho, S K; Chen, P N
2010-01-01
Functional electrical stimulation (FES) and rehabilitation robots are techniques used to assist in post-stroke rehabilitation. However, FES and rehabilitation robots are still separate systems currently; and their combined training effects on persons after experiencing a stroke have not been well studied yet. In this work, a new combined FES-robot system driven by user's voluntary intention was developed for wrist joint training after stroke. The performance of the FES-robot assisted wrist tracking was evaluated on five subjects with chronic stroke. With simultaneous assistance from both the FES and robot parts of the system, the motion accuracy was improved and excessive activation in elbow flexor was reduced during wrist tracking.
Gagnon, Dany H; Vermette, Martin; Duclos, Cyril; Aubertin-Leheudre, Mylène; Ahmed, Sara; Kairy, Dahlia
2017-12-19
The main objectives of this study were to quantify clients' satisfaction and perception upon completion of a locomotor training program with an overground robotic exoskeleton. A group of 14 wheelchair users with a spinal cord injury, who finished a 6-8-week locomotor training program with the robotic exoskeleton (18 training sessions), were invited to complete a web-based electronic questionnaire. This questionnaire encompassed 41 statements organized around seven key domains: overall satisfaction related to the training program, satisfaction related to the overground robotic exoskeleton, satisfaction related to the program attributes, perceived learnability, perceived health benefits and risks and perceived motivation to engage in physical activity. Each statement was rated using a visual analogue scale ranging from "0 = totally disagree" to "100 = completely agree". Overall, respondents unanimously considered themselves satisfied with the locomotor training program with the robotic exoskeleton (95.7 ± 0.7%) and provided positive feedback about the robotic exoskeleton itself (82.3 ± 6.9%), the attributes of the locomotor training program (84.5 ± 6.9%) and their ability to learn to perform sit-stand transfers and walk with the robotic exoskeleton (79.6 ± 17%). Respondents perceived some health benefits (67.9 ± 16.7%) and have reported no fear of developing secondary complications or of potential risk for themselves linked to the use of the robotic exoskeleton (16.7 ± 8.2%). At the end of the program, respondents felt motivated to engage in a regular physical activity program (91.3 ± 0.1%). This study provides new insights on satisfaction and perceptions of wheelchair users while also confirming the relevance to continue to improve such technologies, and informing the development of future clinical trials. Implications for Rehabilitation All long-term manual wheelchair users with a spinal cord injury who participated in the study are unanimously satisfied upon completion of a 6-8-week locomotor training program with the robotic exoskeleton and would recommend the program to their peers. All long-term manual wheelchair users with a spinal cord injury who participated in the study offered positive feedback about the robotic exoskeleton itself and feel it is easy to learn to perform sit-stand transfers and walk with the robotic exoskeleton. All long-term manual wheelchair users with a spinal cord injury who participated in the study predominantly perceived improvements in their overall health status, upper limb strength and endurance as well as in their sleep and psychological well-being upon completion of a 6-8-week locomotor training program with the robotic exoskeleton. All long-term manual wheelchair users with a spinal cord injury who participated in the study unanimously felt motivated to engage in a regular physical activity program adapted to their condition and most of them do plan to continue to participate in moderate-to-strenuous physical exercise. Additional research on clients' perspectives, especially satisfaction with the overground exoskeleton and locomotor training program attributes, is needed.
2018-01-01
Objective This review aims to provide a systematical investigation of clinical effectiveness of active training strategies applied in platform-based ankle robots. Method English-language studies published from Jan 1980 to Aug 2017 were searched from four databases using key words of “Ankle∗” AND “Robot∗” AND “Effect∗ OR Improv∗ OR Increas∗.” Following an initial screening, three rounds of discrimination were successively conducted based on the title, the abstract, and the full paper. Result A total of 21 studies were selected with 311 patients involved; of them, 13 studies applied a single group while another eight studies used different groups for comparison to verify the therapeutic effect. Virtual-reality (VR) game training was applied in 19 studies, while two studies used proprioceptive neuromuscular facilitation (PNF) training. Conclusion Active training techniques delivered by platform ankle rehabilitation robots have been demonstrated with great potential for clinical applications. Training strategies are mostly combined with one another by considering rehabilitation schemes and motion ability of ankle joints. VR game environment has been commonly used with active ankle training. Bioelectrical signals integrated with VR game training can implement intelligent identification of movement intention and assessment. These further provide the foundation for advanced interactive training strategies that can lead to enhanced training safety and confidence for patients and better treatment efficacy. PMID:29675142
Kamnik, Roman; Bajd, Tadej
2007-11-01
The paper presents a novel control approach for the robot-assisted motion augmentation of disabled subjects during the standing-up manoeuvre. The main goal of the proposal is to integrate the voluntary activity of a person in the control scheme of the rehabilitation robot. The algorithm determines the supportive force to be tracked by a robot force controller. The basic idea behind the calculation of supportive force is to quantify the deficit in the dynamic equilibrium of the trunk. The proposed algorithm was implemented as a Kalman filter procedure and evaluated in a simulation environment. The simulation results proved the adequate and robust performance of "patient-driven" robot-assisted standing-up training. In addition, the possibility of varying the training conditions with different degrees of the subject's initiative is demonstrated.
Liu, Yali; Ji, Linhong
2018-02-01
Robot rehabilitation has been a primary therapy method for the urgent rehabilitation demands of paralyzed patients after a stroke. The parameters in rehabilitation training such as the range of the training, which should be adjustable according to each participant's functional ability, are the key factors influencing the effectiveness of rehabilitation therapy. Therapists design rehabilitation projects based on the semiquantitative functional assessment scales and their experience. But these therapies based on therapists' experience cannot be implemented in robot rehabilitation therapy. This paper modeled the global human-robot by Simulink in order to analyze the relationship between the parameters in robot rehabilitation therapy and the patients' movement functional abilities. We compared the shoulder and elbow angles calculated by simulation with the angles recorded by motion capture system while the healthy subjects completed the simulated action. Results showed there was a remarkable correlation between the simulation data and the experiment data, which verified the validity of the human-robot global Simulink model. Besides, the relationship between the circle radius in the drawing tasks in robot rehabilitation training and the active movement degrees of shoulder as well as elbow was also matched by a linear, which also had a remarkable fitting coefficient. The matched linear can be a quantitative reference for the robot rehabilitation training parameters.
Volpe, Bruce T.; Lynch, Daniel; Rykman-Berland, Avrielle; Ferraro, Mark; Galgano, Michael; Hogan, Neville; Krebs, Hermano I.
2016-01-01
Investigators have demonstrated that a variety of intensive movement training protocols for persistent upper limb paralysis in patients with chronic stroke (6 months or more after stroke) improve motor outcome. This randomized controlled study determined in patients with upper limb motor impairment after chronic stroke whether movement therapy delivered by a robot or by a therapist using an intensive training protocol was superior. Robotic training (n = 11) and an intensive movement protocol (n = 10) improved the impairment measures of motor outcome significantly and comparably; there were no significant changes in disability measures. Motor gains were maintained at the 3-month evaluation after training. These data contribute to the growing awareness that persistent impairments in those with chronic stroke may not reflect exhausted capacity for improvement. These new protocols, rendered by either therapist or robot, can be standardized, tested, and replicated, and potentially will contribute to rational activity-based programs. PMID:18184932
Chen, Kai; Xiong, Bo; Ren, Yupeng; Dvorkin, Assaf Y; Gaebler-Spira, Deboah; Sisung, Charles E; Zhang, Li-Qun
2018-01-10
To evaluate the feasibility and effectiveness of a wearable robotic device in guiding isometric torque generation and passive-active movement training for ankle motor recovery in children with acute brain injury. Ten inpatient children with acute brain injury being treated in a rehabilitation hospital. Daily robot-guided ankle passive-active movement therapy for 15 sessions, including isometric torque generation under real-time feedback, stretch-ing, and active movement training with motivating games using a wearable ankle rehabilitation robot. Ankle biomechanical improvements induced by each training session including ankle range of motion (ROM), muscle strength, and clinical (Fugl-Meyer Lower-Extremity (FMLE), Pediatric Balance Scale (PBS)) and biomechanical (ankle ROM and muscle strength) outcomes over 15 training sessions. As training progressed, improvements in biomechanical performance measures followed logarithmic curves. Each training session increased median dorsiflexion active range of motion (AROM) 2.73° (standard deviation (SD) 1.14), dorsiflexion strength 0.87 Nm (SD 0.90), and plantarflexion strength 0.60 Nm (SD 1.19). After 15 training sessions the median FMLE score had increased from 14.0 (SD 10.11) to 23.0 (SD 11.4), PBS had increased from 33.0 (SD 19.99) to 50.0 (SD 23.13) (p < 0.05), median dorsiflexion and plantarflexion strength had improved from 0.21 Nm (SD 4.45) to 4.0 Nm (SD 7.63) and 8.33 Nm (SD 10.18) to 18.45 Nm (SD 14.41), respectively, median dorsiflexion AROM had improved from -10.45° (SD 12.01) to 11.87° (SD 20.69), and median dorsiflexion PROM increased from 20.0° (SD 9.04) to 25.0° (SD 8.03). Isometric torque generation with real-time feedback, stretching and active movement training helped promote neuroplasticity and improve motor performance in children with acute brain injury.
Fluet, Gerard G.; Merians, Alma S.; Qiu, Qinyin; Lafond, Ian; Saleh, Soha; Ruano, Viviana; Delmonico, Andrea R.; Adamovich, Sergei V.
2014-01-01
Background and Purpose A majority of studies examining repetitive task practice facilitated by robots for the treatment of upper extremity paresis utilize standardized protocols applied to large groups. Others utilize interventions tailored to patients but don't describe the clinical decision making process utilized to develop and modify interventions. This case report will describe a robot-based intervention customized to match the goals and clinical presentation of a gentleman with upper extremity hemiparesis secondary to stroke. Methods PM is an 85 year-old man with left hemiparesis secondary to an intracerebral hemorrhage five years prior to examination. Outcomes were measured before and after a one month period of home therapy and after a one month robotic intervention. The intervention was designed to address specific impairments identified during his PT examination. When necessary, activities were modified based on the patient's response to his first week of treatment. Outcomes PM trained twelve sessions using six virtually simulated activities. Modifications to original configurations of these activities resulted in performance improvements in five of these activities. PM demonstrated a 35 second improvement in Jebsen Test of Hand Function time and a 44 second improvement in Wolf Motor Function Test time subsequent to the robotic training intervention. Reaching kinematics, 24 hour activity measurement and the Hand and Activities of Daily Living scales of the Stroke Impact Scale all improved as well. Discussion A customized program of robotically facilitated rehabilitation resulted in large short-term improvements in several measurements of upper extremity function in a patient with chronic hemiparesis. PMID:22592063
Milot, Marie-Hélène; Spencer, Steven J; Chan, Vicky; Allington, James P; Klein, Julius; Chou, Cathy; Bobrow, James E; Cramer, Steven C; Reinkensmeyer, David J
2013-12-19
To date, the limited degrees of freedom (DOF) of most robotic training devices hinders them from providing functional training following stroke. We developed a 6-DOF exoskeleton ("BONES") that allows movement of the upper limb to assist in rehabilitation. The objectives of this pilot study were to evaluate the impact of training with BONES on function of the affected upper limb, and to assess whether multijoint functional robotic training would translate into greater gains in arm function than single joint robotic training also conducted with BONES. Twenty subjects with mild to moderate chronic stroke participated in this crossover study. Each subject experienced multijoint functional training and single joint training three sessions per week, for four weeks, with the order of presentation randomized. The primary outcome measure was the change in Box and Block Test (BBT). The secondary outcome measures were the changes in Fugl-Meyer Arm Motor Scale (FMA), Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and quantitative measures of strength and speed of reaching. These measures were assessed at baseline, after each training period, and at a 3-month follow-up evaluation session. Training with the robotic exoskeleton resulted in significant improvements in the BBT, FMA, WMFT, MAL, shoulder and elbow strength, and reaching speed (p < 0.05); these improvements were sustained at the 3 month follow-up. When comparing the effect of type of training on the gains obtained, no significant difference was noted between multijoint functional and single joint robotic training programs. However, for the BBT, WMFT and MAL, inequality of carryover effects were noted; subsequent analysis on the change in score between the baseline and first period of training again revealed no difference in the gains obtained between the types of training. Training with the 6 DOF arm exoskeleton improved motor function after chronic stroke, challenging the idea that robotic therapy is only useful for impairment reduction. The pilot results presented here also suggest that multijoint functional robotic training is not decisively superior to single joint robotic training. This challenges the idea that functionally-oriented games during training is a key element for improving behavioral outcomes. NCT01050231.
Biofeedback for robotic gait rehabilitation.
Lünenburger, Lars; Colombo, Gery; Riener, Robert
2007-01-23
Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and therapists. The therapists can adapt the therapy and give further instructions to the patients. The feedback might help the patients to adapt their movement patterns and to improve their motivation. While it is assumed that these novel methods also improve training efficacy, the proof will only be possible with future in-depth clinical studies.
Training in urological robotic surgery. Future perspectives.
El Sherbiny, Ahmed; Eissa, Ahmed; Ghaith, Ahmed; Morini, Elena; Marzotta, Lucilla; Sighinolfi, Maria Chiara; Micali, Salvatore; Bianchi, Giampaolo; Rocco, Bernardo
2018-01-01
As robotics are becoming more integrated into the medical field, robotic training is becoming more crucial in order to overcome the lack of experienced robotic surgeons. However, there are several obstacles facing the development of robotic training programs like the high cost of training and the increased operative time during the initial period of the learning curve, which, in turn increase the operative cost. Robotic-assisted laparoscopic prostatectomy is the most commonly performed robotic surgery. Moreover, robotic surgery is becoming more popular among urologic oncologists and pediatric urologists. The need for a standardized and validated robotic training curriculum was growing along with the increased number of urologic centers and institutes adopting the robotic technology. Robotic training includes proctorship, mentorship or fellowship, telementoring, simulators and video training. In this chapter, we are going to discuss the different training methods, how to evaluate robotic skills, the available robotic training curriculum, and the future perspectives.
Nocchi, Federico; Gazzellini, Simone; Grisolia, Carmela; Petrarca, Maurizio; Cannatà, Vittorio; Cappa, Paolo; D'Alessio, Tommaso; Castelli, Enrico
2012-07-24
The potential of robot-mediated therapy and virtual reality in neurorehabilitation is becoming of increasing importance. However, there is limited information, using neuroimaging, on the neural networks involved in training with these technologies. This study was intended to detect the brain network involved in the visual processing of movement during robotic training. The main aim was to investigate the existence of a common cerebral network able to assimilate biological (human upper limb) and non-biological (abstract object) movements, hence testing the suitability of the visual non-biological feedback provided by the InMotion2 Robot. A visual functional Magnetic Resonance Imaging (fMRI) task was administered to 22 healthy subjects. The task required observation and retrieval of motor gestures and of the visual feedback used in robotic training. Functional activations of both biological and non-biological movements were examined to identify areas activated in both conditions, along with differential activity in upper limb vs. abstract object trials. Control of response was also tested by administering trials with congruent and incongruent reaching movements. The observation of upper limb and abstract object movements elicited similar patterns of activations according to a caudo-rostral pathway for the visual processing of movements (including specific areas of the occipital, temporal, parietal, and frontal lobes). Similarly, overlapping activations were found for the subsequent retrieval of the observed movement. Furthermore, activations of frontal cortical areas were associated with congruent trials more than with the incongruent ones. This study identified the neural pathway associated with visual processing of movement stimuli used in upper limb robot-mediated training and investigated the brain's ability to assimilate abstract object movements with human motor gestures. In both conditions, activations were elicited in cerebral areas involved in visual perception, sensory integration, recognition of movement, re-mapping on the somatosensory and motor cortex, storage in memory, and response control. Results from the congruent vs. incongruent trials revealed greater activity for the former condition than the latter in a network including cingulate cortex, right inferior and middle frontal gyrus that are involved in the go-signal and in decision control. Results on healthy subjects would suggest the appropriateness of an abstract visual feedback provided during motor training. The task contributes to highlight the potential of fMRI in improving the understanding of visual motor processes and may also be useful in detecting brain reorganisation during training.
Positive effects of robotic exoskeleton training of upper limb reaching movements after stroke
2012-01-01
This study, conducted in a group of nine chronic patients with right-side hemiparesis after stroke, investigated the effects of a robotic-assisted rehabilitation training with an upper limb robotic exoskeleton for the restoration of motor function in spatial reaching movements. The robotic assisted rehabilitation training was administered for a period of 6 weeks including reaching and spatial antigravity movements. To assess the carry-over of the observed improvements in movement during training into improved function, a kinesiologic assessment of the effects of the training was performed by means of motion and dynamic electromyographic analysis of reaching movements performed before and after training. The same kinesiologic measurements were performed in a healthy control group of seven volunteers, to determine a benchmark for the experimental observations in the patients’ group. Moreover degree of functional impairment at the enrolment and discharge was measured by clinical evaluation with upper limb Fugl-Meyer Assessment scale (FMA, 0–66 points), Modified Ashworth scale (MA, 0–60 pts) and active ranges of motion. The robot aided training induced, independently by time of stroke, statistical significant improvements of kinesiologic (movement time, smoothness of motion) and clinical (4.6 ± 4.2 increase in FMA, 3.2 ± 2.1 decrease in MA) parameters, as a result of the increased active ranges of motion and improved co-contraction index for shoulder extension/flexion. Kinesiologic parameters correlated significantly with clinical assessment values, and their changes after the training were affected by the direction of motion (inward vs. outward movement) and position of target to be reached (ipsilateral, central and contralateral peripersonal space). These changes can be explained as a result of the motor recovery induced by the robotic training, in terms of regained ability to execute single joint movements and of improved interjoint coordination of elbow and shoulder joints. PMID:22681653
Green, Courtney A; Chern, Hueylan; O'Sullivan, Patricia S
2018-02-01
Current robot surgery curricula developed by industry were designed for expert surgeons. We sought to identify the robotic curricula that currently exist in general surgery residencies and describe their components. We identified 12 residency programs with robotic curricula. Using a structured coding form to identify themes including sequence, duration, emphasis and assessment, we generated a descriptive summary. Curricula followed a similar sequence: learners started with online modules and simulation exercises, followed by bedside experience during R2-R3 training years, and then operative opportunities on the console in the final years of training. Consistent portions of the curricula reflect a device-dependent training paradigm; they defined the sequence of instruction. Most curricula lacked specifics on duration and content of training activities. None clearly described cognitive or psychomotor skills needed by residents and none required a proficiency assessment before graduation. Resident-specific robotic curricula remain grounded in initial industrial efforts to train experienced surgeons, are non-specific regarding the type and nature of hands on experience, and do not include discussion of operative technique and surgical concepts. Copyright © 2017 Elsevier Inc. All rights reserved.
2013-01-01
Stroke is a major cause of disability in the world. The activities of upper limb segments are often compromised following a stroke, impairing most daily tasks. Robotic training is now considered amongst the rehabilitation methods applied to promote functional recovery. However, the implementation of robotic devices remains a major challenge for the bioengineering and clinical community. Latest exoskeletons with multiple degrees of freedom (DOF) may become particularly attractive, because of their low apparent inertia, the multiple actuators generating large torques, and the fact that patients can move the arm in the normal wide workspace. A recent study published in JNER by Milot and colleagues underlines that training with a 6-DOF exoskeleton impacts positively on motor function in patients being in stable phase of recovery after a stroke. Also, multi-joint robotic training was not found to be superior to single-joint robotic training. Although it is often considered that rehabilitation should start from simple movements to complex functional movements as the recovery evolves, this study challenges this widespread notion whose scientific basis has remained uncertain. PMID:24354518
Mehrholz, Jan; Hädrich, Anja; Platz, Thomas; Kugler, Joachim; Pohl, Marcus
2012-06-13
Electromechanical and robot-assisted arm training devices are used in rehabilitation, and might help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving generic activities of daily living, arm function, and arm muscle strength in patients after stroke. We will also assess the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched July 2011), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 7), MEDLINE (1950 to July 2011), EMBASE (1980 to July 2011), CINAHL (1982 to July 2011), AMED (1985 to July 2011), SPORTDiscus (1949 to July 2011), PEDro (searched August 2011), COMPENDEX (1972 to July 2011), and INSPEC (1969 to July 2011). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials (RCTs) comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for patients after stroke. Two review authors independently selected trials for inclusion, assessed trial quality, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 19 trials (involving 666 participants) in this update of our review. Electromechanical and robot-assisted arm training did improve activities of daily living (SMD 0.43, 95% confidence interval (CI) 0.11 to 0.75, P = 0.009, I(2) = 67%) as well as arm function (SMD 0.45, 95% CI 0.20 to 0.69, P = 0.0004, I(2) = 45%), but arm muscle strength did not improve (SMD 0.48, 95% CI -0.06 to 1.03, P = 0.08, I(2) = 79%). Electromechanical and robot-assisted arm training did not increase the risk of patients to drop out (RD 0.00, 95% CI -0.04 to 0.04, P = 0.82, I(2) = 0.0%), and adverse events were rare. Patients who receive electromechanical and robot-assisted arm training after stroke are more likely to improve their generic activities of daily living. Paretic arm function may also improve, but not arm muscle strength. However, the results must be interpreted with caution because there were variations between the trials in the duration and amount of training, type of treatment, and in the patient characteristics.
Brain computer interface for operating a robot
NASA Astrophysics Data System (ADS)
Nisar, Humaira; Balasubramaniam, Hari Chand; Malik, Aamir Saeed
2013-10-01
A Brain-Computer Interface (BCI) is a hardware/software based system that translates the Electroencephalogram (EEG) signals produced by the brain activity to control computers and other external devices. In this paper, we will present a non-invasive BCI system that reads the EEG signals from a trained brain activity using a neuro-signal acquisition headset and translates it into computer readable form; to control the motion of a robot. The robot performs the actions that are instructed to it in real time. We have used the cognitive states like Push, Pull to control the motion of the robot. The sensitivity and specificity of the system is above 90 percent. Subjective results show a mixed trend of the difficulty level of the training activities. The quantitative EEG data analysis complements the subjective results. This technology may become very useful for the rehabilitation of disabled and elderly people.
Chen, Kai; Ren, Yupeng; Gaebler-Spira, Deborah; Zhang, Li-Qun
2014-01-01
A portable rehabilitation robot incorporating intelligent stretching, robot-guided voluntary movement training with motivating games and tele-rehabilitation was developed to provide convenient and cost-effective rehabilitation to children with cerebral palsy (CP) and extend rehabilitation care beyond hospital. Clinicians interact with the patients remotely for periodic evaluations and updated guidance. The tele-assisted stretching and active movement training was done over 6-week 18 sessions on the impaired ankle of 23 children with CP in their home setting. Treatment effectiveness was evaluated using biomechanical measures and clinical outcome measures. After the tele-assisted home robotic rehabilitation intervention, there were significant increases in the ankle passive and active range of motion, muscle strength, a decrease in spasticity, and increases in balance and selective control assessment of lower-extremity.
Oza, Chintan S.
2015-01-01
Trunk motor control is crucial for postural stability and propulsion after low thoracic spinal cord injury (SCI) in animals and humans. Robotic rehabilitation aimed at trunk shows promise in SCI animal models and patients. However, little is known about the effect of SCI and robot rehabilitation of trunk on cortical motor representations. We previously showed reorganization of trunk motor cortex after adult SCI. Non-stepping training also exacerbated some SCI-driven plastic changes. Here we examine effects of robot rehabilitation that promotes recovery of hindlimb weight support functions on trunk motor cortex representations. Adult rats spinal transected as neonates (NTX rats) at the T9/10 level significantly improve function with our robot rehabilitation paradigm, whereas treadmill-only trained do not. We used intracortical microstimulation to map motor cortex in two NTX groups: (1) treadmill trained (control group); and (2) robot-assisted treadmill trained (improved function group). We found significant robot rehabilitation-driven changes in motor cortex: (1) caudal trunk motor areas expanded; (2) trunk coactivation at cortex sites increased; (3) richness of trunk cortex motor representations, as examined by cumulative entropy and mutual information for different trunk representations, increased; (4) trunk motor representations in the cortex moved toward more normal topography; and (5) trunk and forelimb motor representations that SCI-driven plasticity and compensations had caused to overlap were segregated. We conclude that effective robot rehabilitation training induces significant reorganization of trunk motor cortex and partially reverses some plastic changes that may be adaptive in non-stepping paraplegia after SCI. PMID:25948267
Colombo, Roberto; Sterpi, Irma; Mazzone, Alessandra; Delconte, Carmen; Pisano, Fabrizio
2012-05-01
In robot-assisted neurorehabilitation, matching the task difficulty level to the patient's needs and abilities, both initially and as the relearning process progresses, can enhance the effectiveness of training and improve patients' motivation and outcome. This study presents a Progressive Task Regulation algorithm implemented in a robot for upper limb rehabilitation. It evaluates the patient's performance during training through the computation of robot-measured parameters, and automatically changes the features of the reaching movements, adapting the difficulty level of the motor task to the patient's abilities. In particular, it can select different types of assistance (time-triggered, activity-triggered, and negative assistance) and implement varied therapy practice to promote generalization processes. The algorithm was tuned by assessing the performance data obtained in 22 chronic stroke patients who underwent robotic rehabilitation, in which the difficulty level of the task was manually adjusted by the therapist. Thus, we could verify the patient's recovery strategies and implement task transition rules to match both the patient's and therapist's behavior. In addition, the algorithm was tested in a sample of five chronic stroke patients. The findings show good agreement with the therapist decisions so indicating that it could be useful for the implementation of training protocols allowing individualized and gradual treatment of upper limb disabilities in patients after stroke. The application of this algorithm during robot-assisted therapy should allow an easier management of the different motor tasks administered during training, thereby facilitating the therapist's activity in the treatment of different pathologic conditions of the neuromuscular system.
Hand Robotic Therapy in Children with Hemiparesis: A Pilot Study.
Bishop, Lauri; Gordon, Andrew M; Kim, Heakyung
2017-01-01
The aim of this study was to understand the impact of training with a hand robotic device on hand paresis and function in a population of children with hemiparesis. Twelve children with hemiparesis (mean age, 9 [SD, 3.64] years) completed participation in this prospective, experimental, pilot study. Participants underwent clinical assessments at baseline and again 6 weeks later with instructions to not initiate new therapies. After these assessments, participants received 6 weeks of training with a hand robotic device, consisting of 1-hour sessions, 3 times weekly. Assessments were repeated on completion of training. Results showed significant improvements after training on the Assisting Hand Assessment (mean difference, 2.0 Assisting Hand Assessment units; P = 0.011) and on the upper-extremity component of the Fugl-Meyer scale (raw score mean difference, 4.334; P = 0.001). No significant improvements between pretest and posttest were noted on the Jebsen-Taylor Test of Hand Function, the Quality of Upper Extremity Skills Test, or the Pediatric Evaluation of Disability Inventory after intervention. Total active mobility of digits and grip strength also failed to demonstrate significant changes after training. Participants tolerated training with the hand robotic device, and significant improvements in bimanual hand use, as well as impairment-based scales, were noted. Improvements were carried over into bimanual skills during play. Complete the self-assessment activity and evaluation online at http://www.physiatry.org/JournalCME CME OBJECTIVES: Upon completion of this article, the reader should be able to: (1) Understand key components of neuroplasticity; (2) Discuss the benefits of robotic therapy in the recovery of hand function in pediatric patients with hemiplegia; and (3) Appropriately incorporate robotic therapy into the treatment plan of pediatric patients with hemiplegia. Advanced ACCREDITATION: The Association of Academic Physiatrists is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians.The Association of Academic Physiatrists designates this activity for a maximum of 1.5 AMA PRA Category 1 Credit(s)™. Physicians should only claim credit commensurate with the extent of their participation in the activity.
Bragoni, Maura; Broccoli, Marco; Iosa, Marco; Morone, Giovanni; De Angelis, Domenico; Venturiero, Vincenzo; Coiro, Paola; Pratesi, Luca; Mezzetti, Giulia; Fusco, Augusto; Paolucci, Stefano
2013-10-01
The aim of this study was to investigate whether the rehabilitation outcomes with robotic-aided gait therapy may be affected by patients' and caregivers' psychologic features after subacute stroke. This is a controlled, longitudinal, observational pilot study conducted on 42 patients divided in robotic-assisted gait training plus conventional physical therapy group, robotic-assisted gait training dropout group, and conventional physical therapy group. The outcome measures were walking ability (Functional Ambulation Category) and independency in activities of daily living (Barthel Index) measured before and after intervention. Psychologic features were measured before intervention using the Hospital Anxiety and Depression Scale, the Eysenck Personality Questionnaire, and recovery locus of control in the patients and the State-Trait Anxiety Inventory and the Beck Depression Inventory in the caregivers. Patient anxiety was significantly higher in those who refused/abandoned robotic therapy (P = 0.002). In the subjects allocated to the robotic group, the recovery of walking ability was significantly affected by the perceived recovery locus of control (P = 0.039, odds ratio = 14); and the recovery of independency in activities of daily living, by anxiety (P = 0.018, odds ratio = 0.042). Conversely, psychologic factors did not significantly affect the outcomes of conventional rehabilitation. Psychologic features, particularly recovery locus of control and anxiety, affected the rehabilitative outcomes of the patients involved in robotic treatment more than those in conventional rehabilitation.
Nessler, Jeff A; Moustafa-Bayoumi, Moustafa; Soto, Dalziel; Duhon, Jessica; Schmitt, Ryan
2011-12-01
Robotic locomotor training devices have gained popularity in recent years, yet little has been reported regarding contact forces experienced by the subject performing automated locomotor training, particularly in animal models of neurological injury. The purpose of this study was to develop a means for acquiring contact forces between a robotic device and a rodent model of spinal cord injury through instrumentation of a robotic gait training device (the rat stepper) with miniature force/torque sensors. Sensors were placed at each interface between the robot arm and animal's hindlimb and underneath the stepping surface of both hindpaws (four sensors total). Twenty four female, Sprague-Dawley rats received mid-thoracic spinal cord transections as neonates and were included in the study. Of these 24 animals, training began for 18 animals at 21 days of age and continued for four weeks at five min/day, five days/week. The remaining six animals were untrained. Animal-robot contact forces were acquired for trained animals weekly and untrained animals every two weeks while stepping in the robotic device with both 60 and 90% of their body weight supported (BWS). Animals that received training significantly increased the number of weight supported steps over the four week training period. Analysis of raw contact forces revealed significant increases in forward swing and ground reaction forces during this time, and multiple aspects of animal-robot contact forces were significantly correlated with weight bearing stepping. However, when contact forces were normalized to animal body weight, these increasing trends were no longer present. Comparison of trained and untrained animals revealed significant differences in normalized ground reaction forces (both horizontal and vertical) and normalized forward swing force. Finally, both forward swing and ground reaction forces were significantly reduced at 90% BWS when compared to the 60% condition. These results suggest that measurement of animal-robot contact forces using the instrumented rat stepper can provide a sensitive and reliable measure of hindlimb locomotor strength and control of flexor and extensor muscle activity in neurologically impaired animals. Additionally, these measures may be useful as a means to quantify training intensity or dose-related functional outcomes of automated training.
Bae, Young-Hyeon; Ko, Young Jun; Chang, Won Hyuk; Lee, Ju Hyeok; Lee, Kyeong Bong; Park, Yoo Jung; Ha, Hyun Geun; Kim, Yun-Hee
2014-12-01
[Purpose] The purpose of the present study was to investigate the effects of robot-assisted gait training combined with functional electrical stimulation on locomotor recovery in patients with chronic stroke. [Subjects] The 20 subjects were randomly assigned into either an experimental group (n = 10) that received a combination of robot-assisted gait training and functional electrical stimulation on the ankle dorsiflexor of the affected side or a control group (n = 10) that received robot-assisted gait training only. [Methods] Both groups received the respective therapies for 30 min/day, 3 days/week for 5 weeks. The outcome was measured using the Modified Motor Assessment Scale (MMAS), Timed Up-and-Go Test (TUG), Berg Balance Scale (BBS), and gait parameters through gait analysis (Vicon 370 motion analysis system, Oxford Metrics Ltd., Oxford, UK). All the variables were measured before and after training. [Results] Step length and maximal knee extension were significantly greater than those before training in the experimental group only. Maximal Knee flexion showed a significant difference between the experimental and control groups. The MMAS, BBS, and TUG scores improved significantly after training compared with before training in both groups. [Conclusion] We suggest that the combination of robot-assisted gait training and functional electrical stimulation encourages patients to actively participate in training because it facilitates locomotor recovery without the risk of adverse effects.
Biofeedback for robotic gait rehabilitation
Lünenburger, Lars; Colombo, Gery; Riener, Robert
2007-01-01
Background Development and increasing acceptance of rehabilitation robots as well as advances in technology allow new forms of therapy for patients with neurological disorders. Robot-assisted gait therapy can increase the training duration and the intensity for the patients while reducing the physical strain for the therapist. Optimal training effects during gait therapy generally depend on appropriate feedback about performance. Compared to manual treadmill therapy, there is a loss of physical interaction between therapist and patient with robotic gait retraining. Thus, it is difficult for the therapist to assess the necessary feedback and instructions. The aim of this study was to define a biofeedback system for a gait training robot and test its usability in subjects without neurological disorders. Methods To provide an overview of biofeedback and motivation methods applied in gait rehabilitation, previous publications and results from our own research are reviewed. A biofeedback method is presented showing how a rehabilitation robot can assess the patients' performance and deliver augmented feedback. For validation, three subjects without neurological disorders walked in a rehabilitation robot for treadmill training. Several training parameters, such as body weight support and treadmill speed, were varied to assess the robustness of the biofeedback calculation to confounding factors. Results The biofeedback values correlated well with the different activity levels of the subjects. Changes in body weight support and treadmill velocity had a minor effect on the biofeedback values. The synchronization of the robot and the treadmill affected the biofeedback values describing the stance phase. Conclusion Robot-aided assessment and feedback can extend and improve robot-aided training devices. The presented method estimates the patients' gait performance with the use of the robot's existing sensors, and displays the resulting biofeedback values to the patients and therapists. The therapists can adapt the therapy and give further instructions to the patients. The feedback might help the patients to adapt their movement patterns and to improve their motivation. While it is assumed that these novel methods also improve training efficacy, the proof will only be possible with future in-depth clinical studies. PMID:17244363
[Robot-aided training in rehabilitation].
Hachisuka, Kenji
2010-02-01
Recently, new training techniques that involve the use of robots have been used in the rehabilitation of patients with hemiplegia and paraplegia. Robots used for training the arm include the MIT-MANUS, Arm Trainer, mirror-image motion enabler (MIME) robot, and the assisted rehabilitation and measurement (ARM) Guide. Robots that are used for lower-limb training are the Rehabot, Gait Trainer, Lokomat, LOPES Exoskeleton Robot, and Gait Assist Robot. Robot-aided therapy has enabled the functional training of the arm and the lower limbs in an effective, easy, and comfortable manner. Therefore, with this type of therapy, the patients can repeatedly undergo sufficient and accurate training for a prolonged period. However, evidence of the benefits of robot-aided training has not yet been established.
Oza, Chintan S; Giszter, Simon F
2015-05-06
Trunk motor control is crucial for postural stability and propulsion after low thoracic spinal cord injury (SCI) in animals and humans. Robotic rehabilitation aimed at trunk shows promise in SCI animal models and patients. However, little is known about the effect of SCI and robot rehabilitation of trunk on cortical motor representations. We previously showed reorganization of trunk motor cortex after adult SCI. Non-stepping training also exacerbated some SCI-driven plastic changes. Here we examine effects of robot rehabilitation that promotes recovery of hindlimb weight support functions on trunk motor cortex representations. Adult rats spinal transected as neonates (NTX rats) at the T9/10 level significantly improve function with our robot rehabilitation paradigm, whereas treadmill-only trained do not. We used intracortical microstimulation to map motor cortex in two NTX groups: (1) treadmill trained (control group); and (2) robot-assisted treadmill trained (improved function group). We found significant robot rehabilitation-driven changes in motor cortex: (1) caudal trunk motor areas expanded; (2) trunk coactivation at cortex sites increased; (3) richness of trunk cortex motor representations, as examined by cumulative entropy and mutual information for different trunk representations, increased; (4) trunk motor representations in the cortex moved toward more normal topography; and (5) trunk and forelimb motor representations that SCI-driven plasticity and compensations had caused to overlap were segregated. We conclude that effective robot rehabilitation training induces significant reorganization of trunk motor cortex and partially reverses some plastic changes that may be adaptive in non-stepping paraplegia after SCI. Copyright © 2015 the authors 0270-6474/15/357174-16$15.00/0.
MERIANS, A. S.; TUNIK, E.; FLUET, G. G.; QIU, Q.; ADAMOVICH, S. V.
2017-01-01
Aim Upper-extremity interventions for hemiparesis are a challenging aspect of stroke rehabilitation. Purpose of this paper is to report the feasibility of using virtual environments (VEs) in combination with robotics to assist recovery of hand-arm function and to present preliminary data demonstrating the potential of using sensory manipulations in VE to drive activation in targeted neural regions. Methods We trained 8 subjects for 8 three hour sessions using a library of complex VE’s integrated with robots, comparing training arm and hand separately to training arm and hand together. Instrumented gloves and hand exoskeleton were used for hand tracking and haptic effects. Haptic Master robotic arm was used for arm tracking and generating three-dimensional haptic VEs. To investigate the use of manipulations in VE to drive neural activations, we created a “virtual mirror” that subjects used while performing a unimanual task. Cortical activation was measured with functional MRI (fMRI) and transcranial magnetic stimulation. Results Both groups showed improvement in kinematics and measures of real-world function. The group trained using their arm and hand together showed greater improvement. In a stroke subject, fMRI data suggested virtual mirror feedback could activate the sensorimotor cortex contralateral to the reflected hand (ipsilateral to the moving hand) thus recruiting the lesioned hemisphere. Conclusion Gaming simulations interfaced with robotic devices provide a training medium that can modify movement patterns. In addition to showing that our VE therapies can optimize behavioral performance, we show preliminary evidence to support the potential of using specific sensory manipulations to selectively recruit targeted neural circuits. PMID:19158659
Rowe, Justin B; Chan, Vicky; Ingemanson, Morgan L; Cramer, Steven C; Wolbrecht, Eric T; Reinkensmeyer, David J
2017-08-01
Robots that physically assist movement are increasingly used in rehabilitation therapy after stroke, yet some studies suggest robotic assistance discourages effort and reduces motor learning. To determine the therapeutic effects of high and low levels of robotic assistance during finger training. We designed a protocol that varied the amount of robotic assistance while controlling the number, amplitude, and exerted effort of training movements. Participants (n = 30) with a chronic stroke and moderate hemiparesis (average Box and Blocks Test 32 ± 18 and upper extremity Fugl-Meyer score 46 ± 12) actively moved their index and middle fingers to targets to play a musical game similar to GuitarHero 3 h/wk for 3 weeks. The participants were randomized to receive high assistance (causing 82% success at hitting targets) or low assistance (55% success). Participants performed ~8000 movements during 9 training sessions. Both groups improved significantly at the 1-month follow-up on functional and impairment-based motor outcomes, on depression scores, and on self-efficacy of hand function, with no difference between groups in the primary endpoint (change in Box and Blocks). High assistance boosted motivation, as well as secondary motor outcomes (Fugl-Meyer and Lateral Pinch Strength)-particularly for individuals with more severe finger motor deficits. Individuals with impaired finger proprioception at baseline benefited less from the training. Robot-assisted training can promote key psychological outcomes known to modulate motor learning and retention. Furthermore, the therapeutic effectiveness of robotic assistance appears to derive at least in part from proprioceptive stimulation, consistent with a Hebbian plasticity model.
Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard
2015-11-07
Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P < 0.0001, I² = 36%), and arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low. Electromechanical and robot-assisted arm training did not increase the risk of participant drop-out (RD 0.00, 95% CI -0.02 to 0.03, P = 0.84, I² = 0%) with moderate-quality evidence, and adverse events were rare. People who receive electromechanical and robot-assisted arm and hand training after stroke might improve their activities of daily living, arm and hand function, and arm and hand muscle strength. However, the results must be interpreted with caution because the quality of the evidence was low to very low, and there were variations between the trials in the intensity, duration, and amount of training; type of treatment; and participant characteristics.
Human-like Compliance for Dexterous Robot Hands
NASA Technical Reports Server (NTRS)
Jau, Bruno M.
1995-01-01
This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.
Hu, Xiao-Ling; Tong, Raymond Kai-yu; Ho, Newmen S K; Xue, Jing-jing; Rong, Wei; Li, Leonard S W
2015-09-01
Augmented physical training with assistance from robot and neuromuscular electrical stimulation (NMES) may introduce intensive motor improvement in chronic stroke. To compare the rehabilitation effectiveness achieved by NMES robot-assisted wrist training and that by robot-assisted training. This study was a single-blinded randomized controlled trial with a 3-month follow-up. Twenty-six hemiplegic subjects with chronic stroke were randomly assigned to receive 20-session wrist training with an electromyography (EMG)-driven NMES robot (NMES robot group, n = 11) and with an EMG-driven robot (robot group, n = 15), completed within 7 consecutive weeks. Clinical scores, Fugl-Meyer Assessment (FMA), Modified Ashworth Score (MAS), and Action Research Arm Test (ARAT) were used to evaluate the training effects before and after the training, as well as 3 months later. An EMG parameter, muscle co-contraction index, was also applied to investigate the session-by-session variation in muscular coordination patterns during the training. The improvement in FMA (shoulder/elbow, wrist/hand) obtained in the NMES robot group was more significant than the robot group (P < .05). Significant improvement in ARAT was achieved in the NMES robot group (P < .05) but absent in the robot group. NMES robot-assisted training showed better performance in releasing muscle co-contraction than the robot-assisted across the training sessions (P < .05). The NMES robot-assisted wrist training was more effective than the pure robot. The additional NMES application in the treatment could bring more improvements in the distal motor functions and faster rehabilitation progress. © The Author(s) 2014.
Competencies Identification for Robotics Training.
ERIC Educational Resources Information Center
Tang, Le D.
A study focused on the task of identifying competencies for robotics training. The level of robotics training was limited to that of robot technicians. Study objectives were to obtain a list of occupational competencies; to rank their order of importance; and to compare opinions from robot manufacturers, robot users, and robotics educators…
Huang, Xianwei; Naghdy, Fazel; Naghdy, Golshah; Du, Haiping; Todd, Catherine
2018-01-01
Robot-assisted therapy is regarded as an effective and reliable method for the delivery of highly repetitive training that is needed to trigger neuroplasticity following a stroke. However, the lack of fully adaptive assist-as-needed control of the robotic devices and an inadequate immersive virtual environment that can promote active participation during training are obstacles hindering the achievement of better training results with fewer training sessions required. This study thus focuses on these research gaps by combining these 2 key components into a rehabilitation system, with special attention on the rehabilitation of fine hand motion skills. The effectiveness of the proposed system is tested by conducting clinical trials on a chronic stroke patient and verified through clinical evaluation methods by measuring the key kinematic features such as active range of motion (ROM), finger strength, and velocity. By comparing the pretraining and post-training results, the study demonstrates that the proposed method can further enhance the effectiveness of fine hand motion rehabilitation training by improving finger ROM, strength, and coordination. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Variety Wins: Soccer-Playing Robots and Infant Walking.
Ossmy, Ori; Hoch, Justine E; MacAlpine, Patrick; Hasan, Shohan; Stone, Peter; Adolph, Karen E
2018-01-01
Although both infancy and artificial intelligence (AI) researchers are interested in developing systems that produce adaptive, functional behavior, the two disciplines rarely capitalize on their complementary expertise. Here, we used soccer-playing robots to test a central question about the development of infant walking. During natural activity, infants' locomotor paths are immensely varied. They walk along curved, multi-directional paths with frequent starts and stops. Is the variability observed in spontaneous infant walking a "feature" or a "bug?" In other words, is variability beneficial for functional walking performance? To address this question, we trained soccer-playing robots on walking paths generated by infants during free play and tested them in simulated games of "RoboCup." In Tournament 1, we compared the functional performance of a simulated robot soccer team trained on infants' natural paths with teams trained on less varied, geometric paths-straight lines, circles, and squares. Across 1,000 head-to-head simulated soccer matches, the infant-trained team consistently beat all teams trained with less varied walking paths. In Tournament 2, we compared teams trained on different clusters of infant walking paths. The team trained with the most varied combination of path shape, step direction, number of steps, and number of starts and stops outperformed teams trained with less varied paths. This evidence indicates that variety is a crucial feature supporting functional walking performance. More generally, we propose that robotics provides a fruitful avenue for testing hypotheses about infant development; reciprocally, observations of infant behavior may inform research on artificial intelligence.
Survey of minimally invasive general surgery fellows training in robotic surgery.
Shaligram, Abhijit; Meyer, Avishai; Simorov, Anton; Pallati, Pradeep; Oleynikov, Dmitry
2013-06-01
Minimally invasive surgery fellowships offer experience in robotic surgery, the nature of which is poorly defined. The objective of this survey was to determine the current status and opportunities for robotic surgery training available to fellows training in the United States and Canada. Sixty-five minimally invasive surgery fellows, attending a fundamentals of fellowship conference, were asked to complete a questionnaire regarding their demographics and experiences with robotic surgery and training. Fifty-one of the surveyed fellows completed the questionnaire (83 % response). Seventy-two percent of respondents had staff surgeons trained in performing robotic procedures, with 55 % of respondents having general surgery procedures performed robotically at their institution. Just over half (53 %) had access to a simulation facility for robotic training. Thirty-three percent offered mechanisms for certification and 11 % offered fellowships in robotic surgery. One-third of the minimally invasive surgery fellows felt they had been trained in robotic surgery and would consider making it part of their practice after fellowship. However, most (80 %) had no plans to pursue robotic surgery fellowships. Although a large group (63 %) felt optimistic about the future of robotic surgery, most respondents (72.5 %) felt their current experience with robotic surgery training was poor or below average. There is wide variation in exposure to and training in robotic surgery in minimally invasive surgery fellowship programs in the United States and Canada. Although a third of trainees felt adequately trained for performing robotic procedures, most fellows felt that their current experience with training was not adequate.
[Rehabilitation and nursing-care robots].
Hachisuka, Kenji
2016-04-01
In the extremely aged society, rehabilitation staff will be required to provide ample rehabilitation training for more stroke patients and more aged people with disabilities despite limitations in human resources. A nursing-care robot is one potential solution from the standpoint of rehabilitation. The nursing-care robot is defined as a robot which assists aged people and persons with disabilities in daily life and social life activities. The nursing-care robot consists of an independent support robot, caregiver support robot, and life support robot. Although many nursing-care robots have been developed, the most appropriate robot must be selected according to its features and the needs of patients and caregivers in the field of nursing-care.
Training and learning robotic surgery, time for a more structured approach: a systematic review.
Schreuder, H W R; Wolswijk, R; Zweemer, R P; Schijven, M P; Verheijen, R H M
2012-01-01
Robotic assisted laparoscopic surgery is growing rapidly and there is an increasing need for a structured approach to train future robotic surgeons. To review the literature on training and learning strategies for robotic assisted laparoscopic surgery. A systematic search of MEDLINE, EMBASE, the Cochrane Library and the Journal of Robotic Surgery was performed. We included articles concerning training, learning, education and teaching of robotic assisted laparoscopic surgery in any specialism. Two authors independently selected articles to be included. We categorised the included articles into: training modalities, learning curve, training future surgeons, curriculum design and implementation. We included 114 full text articles. Training modalities such as didactic training, skills training (dry lab, virtual reality, animal or cadaver models), case observation, bedside assisting, proctoring and the mentoring console can be used for training in robotic assisted laparoscopic surgery. Several training programmes in general and specific programmes designed for residents, fellows and surgeons are described in the literature. We provide guidelines for development of a structured training programme. Robotic surgical training consists of system training and procedural training. System training should be formally organised and should be competence based, instead of time based. Virtual reality training will play an import role in the near future. Procedural training should be organised in a stepwise approach with objective assessment of each step. This review aims to facilitate and improve the implementation of structured robotic surgical training programmes. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.
Current status of robotic simulators in acquisition of robotic surgical skills.
Kumar, Anup; Smith, Roger; Patel, Vipul R
2015-03-01
This article provides an overview of the current status of simulator systems in robotic surgery training curriculum, focusing on available simulators for training, their comparison, new technologies introduced in simulation focusing on concepts of training along with existing challenges and future perspectives of simulator training in robotic surgery. The different virtual reality simulators available in the market like dVSS, dVT, RoSS, ProMIS and SEP have shown face, content and construct validity in robotic skills training for novices outside the operating room. Recently, augmented reality simulators like HoST, Maestro AR and RobotiX Mentor have been introduced in robotic training providing a more realistic operating environment, emphasizing more on procedure-specific robotic training . Further, the Xperience Team Trainer, which provides training to console surgeon and bed-side assistant simultaneously, has been recently introduced to emphasize the importance of teamwork and proper coordination. Simulator training holds an important place in current robotic training curriculum of future robotic surgeons. There is a need for more procedure-specific augmented reality simulator training, utilizing advancements in computing and graphical capabilities for new innovations in simulator technology. Further studies are required to establish its cost-benefit ratio along with concurrent and predictive validity.
Robotic Surgical Training in an Academic Institution
Chitwood, W. Randolph; Nifong, L. Wiley; Chapman, William H. H.; Felger, Jason E.; Bailey, B. Marcus; Ballint, Tara; Mendleson, Kim G.; Kim, Victor B.; Young, James A.; Albrecht, Robert A.
2001-01-01
Objective To detail robotic procedure development and clinical applications for mitral valve, biliary, and gastric reflux operations, and to implement a multispecialty robotic surgery training curriculum for both surgeons and surgical teams. Summary Background Data Remote, accurate telemanipulation of intracavitary instruments by general and cardiac surgeons is now possible. Complex technologic advancements in surgical robotics require well-designed training programs. Moreover, efficient robotic surgical procedures must be developed methodically and safely implemented clinically. Methods Advanced training on robotic systems provides surgeon confidence when operating in tiny intracavitary spaces. Three-dimensional vision and articulated instrument control are essential. The authors’ two da Vinci robotic systems have been dedicated to procedure development, clinical surgery, and training of surgical specialists. Their center has been the first United States site to train surgeons formally in clinical robotics. Results Established surgeons and residents have been trained using a defined robotic surgical educational curriculum. Also, 30 multispecialty teams have been trained in robotic mechanics and electronics. Initially, robotic procedures were developed experimentally and are described. In the past year the authors have performed 52 robotic-assisted clinical operations: 18 mitral valve repairs, 20 cholecystectomies, and 14 Nissen fundoplications. These respective operations required 108, 28, and 73 minutes of robotic telemanipulation to complete. Procedure times for the last half of the abdominal operations decreased significantly, as did the knot-tying time in mitral operations. There have been no deaths and few complications. One mitral patient had postoperative bleeding. Conclusion Robotic surgery can be performed safely with excellent results. The authors have developed an effective curriculum for training teams in robotic surgery. After training, surgeons have applied these methods effectively and safely. PMID:11573041
Biomedical applications of soft robotics
NASA Astrophysics Data System (ADS)
Cianchetti, Matteo; Laschi, Cecilia; Menciassi, Arianna; Dario, Paolo
2018-06-01
Soft robotics enables the design of soft machines and devices at different scales. The compliance and mechanical properties of soft robots make them especially interesting for medical applications. Depending on the level of interaction with humans, different levels of biocompatibility and biomimicry are required for soft materials used in robots. In this Review, we investigate soft robots for biomedical applications, including soft tools for surgery, diagnosis and drug delivery, wearable and assistive devices, prostheses, artificial organs and tissue-mimicking active simulators for training and biomechanical studies. We highlight challenges regarding durability and reliability, and examine traditional and novel soft and active materials as well as different actuation strategies. Finally, we discuss future approaches and applications in the field.
The effects of post-stroke upper-limb training with an electromyography (EMG)-driven hand robot.
Hu, X L; Tong, K Y; Wei, X J; Rong, W; Susanto, E A; Ho, S K
2013-10-01
Loss of hand function and finger dexterity are main disabilities in the upper limb after stroke. An electromyography (EMG)-driven hand robot had been developed for post-stroke rehabilitation training. The effectiveness of the hand robot assisted whole upper limb training was investigated on persons with chronic stroke (n=10) in this work. All subjects attended a 20-session training (3-5times/week) by using the hand robot to practice object grasp/release and arm transportation tasks. Significant motor improvements were observed in the Fugl-Meyer hand/wrist and shoulder/elbow scores (p<0.05), and also in the Action Research Arm Test and Wolf Motor Function Test (p<0.05). Significant reduction in spasticity of the fingers as was measured by the Modified Ashworth Score (p<0.05). The training improved the muscle co-ordination between the antagonist muscle pair (flexor digitorum (FD) and extensor digitorum (ED)), associated with a significant reduction in the ED EMG level (p<0.05) and a significant decrease of ED and FD co-contraction during the training (p<0.05); the excessive muscle activities in the biceps brachii were also reduced significantly after the training (p<0.05). Copyright © 2013 Elsevier Ltd. All rights reserved.
Modular ankle robotics training in early subacute stroke: a randomized controlled pilot study.
Forrester, Larry W; Roy, Anindo; Krywonis, Amanda; Kehs, Glenn; Krebs, Hermano Igo; Macko, Richard F
2014-09-01
BACKGROUND. Modular lower extremity robotics may offer a valuable avenue for restoring neuromotor control after hemiparetic stroke. Prior studies show that visually guided and visually evoked practice with an ankle robot (anklebot) improves paretic ankle motor control that translates into improved overground walking. To assess the feasibility and efficacy of daily anklebot training during early subacute hospitalization poststroke. Thirty-four inpatients from a stroke unit were randomly assigned to anklebot (n = 18) or passive manual stretching (n = 16) treatments. All suffered a first stroke with residual hemiparesis (ankle manual muscle test grade 1/5 to 4/5), and at least trace muscle activation in plantar- or dorsiflexion. Anklebot training employed an "assist-as-needed" approach during >200 volitional targeted paretic ankle movements, with difficulty adjusted to active range of motion and success rate. Stretching included >200 daily mobilizations in these same ranges. All sessions lasted 1 hour and assessments were not blinded. Both groups walked faster at discharge; however, the robot group improved more in percentage change of temporal symmetry (P = .032) and also of step length symmetry (P = .038), with longer nonparetic step lengths in the robot (133%) versus stretching (31%) groups. Paretic ankle control improved in the robot group, with increased peak (P ≤ .001) and mean (P ≤ .01) angular speeds, and increased movement smoothness (P ≤ .01). There were no adverse events. Though limited by small sample size and restricted entry criteria, our findings suggest that modular lower extremity robotics during early subacute hospitalization is well tolerated and improves ankle motor control and gait patterning. © The Author(s) 2014.
Chen, Kai; Wu, Yi-Ning; Ren, Yupeng; Liu, Lin; Gaebler-Spira, Deborah; Tankard, Kelly; Lee, Julia; Song, Weiqun; Wang, Maobin; Zhang, Li-Qun
2016-08-01
To examine the outcomes of home-based robot-guided therapy and compare it to laboratory-based robot-guided therapy for the treatment of impaired ankles in children with cerebral palsy. A randomized comparative trial design comparing a home-based training group and a laboratory-based training group. Home versus laboratory within a research hospital. Children (N=41) with cerebral palsy who were at Gross Motor Function Classification System level I, II, or III were randomly assigned to 2 groups. Children in home-based and laboratory-based groups were 8.7±2.8 (n=23) and 10.7±6.0 (n=18) years old, respectively. Six-week combined passive stretching and active movement intervention of impaired ankle in a laboratory or home environment using a portable rehabilitation robot. Active dorsiflexion range of motion (as the primary outcome), mobility (6-minute walk test and timed Up and Go test), balance (Pediatric Balance Scale), Selective Motor Control Assessment of the Lower Extremity, Modified Ashworth Scale (MAS) for spasticity, passive range of motion (PROM), strength, and joint stiffness. Significant improvements were found for the home-based group in all biomechanical outcome measures except for PROM and all clinical outcome measures except the MAS. The laboratory-based group also showed significant improvements in all the biomechanical outcome measures and all clinical outcome measures except the MAS. There were no significant differences in the outcome measures between the 2 groups. These findings suggest that the translation of repetitive, goal-directed, biofeedback training through motivating games from the laboratory to the home environment is feasible. The benefits of home-based robot-guided therapy were similar to those of laboratory-based robot-guided therapy. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Variety Wins: Soccer-Playing Robots and Infant Walking
Ossmy, Ori; Hoch, Justine E.; MacAlpine, Patrick; Hasan, Shohan; Stone, Peter; Adolph, Karen E.
2018-01-01
Although both infancy and artificial intelligence (AI) researchers are interested in developing systems that produce adaptive, functional behavior, the two disciplines rarely capitalize on their complementary expertise. Here, we used soccer-playing robots to test a central question about the development of infant walking. During natural activity, infants' locomotor paths are immensely varied. They walk along curved, multi-directional paths with frequent starts and stops. Is the variability observed in spontaneous infant walking a “feature” or a “bug?” In other words, is variability beneficial for functional walking performance? To address this question, we trained soccer-playing robots on walking paths generated by infants during free play and tested them in simulated games of “RoboCup.” In Tournament 1, we compared the functional performance of a simulated robot soccer team trained on infants' natural paths with teams trained on less varied, geometric paths—straight lines, circles, and squares. Across 1,000 head-to-head simulated soccer matches, the infant-trained team consistently beat all teams trained with less varied walking paths. In Tournament 2, we compared teams trained on different clusters of infant walking paths. The team trained with the most varied combination of path shape, step direction, number of steps, and number of starts and stops outperformed teams trained with less varied paths. This evidence indicates that variety is a crucial feature supporting functional walking performance. More generally, we propose that robotics provides a fruitful avenue for testing hypotheses about infant development; reciprocally, observations of infant behavior may inform research on artificial intelligence. PMID:29867427
Peterson, Shannon; Mayer, Allan; Nelson, Beth; Roland, Phillip
2015-08-01
Many community hospital gynecologic surgery training programs now include robotics.At St. Francis Hospital and Medical Center, we have integrated robotic surgical training since 2006. This study is designed to assess the success in training gynecology residents in robotic surgery. An anonymous web-based survey tool (www. survey monkey. com) was sent to all Ob/Gyn residency graduates from 2007-2010 (n = 17). From 2011-2014, we emailed three reevaluation questions to all 2007-2014 graduates (N = 32). Design Classification: II-3. The response rate was 95%, and 11 of 17 initial graduates (65%) indicated that they had received adequate robotic training. Currently, 24 of 32 (75%) graduates practice in hospitals with robotic availability. Twenty of the 32 graduates (63%) are using robotics in their surgical practices. Nine of these 20 graduates (45%) were fully credentialed following their residency. The other 11 graduates (55%)required further proctoring to obtain full robotic credentials. Robotic surgical training is a component of modern gynecologic surgical training. Postresidency robotic credentialing is a realistic graduation goal for residents who plan to practice gynecologic surgery.
Raven surgical robot training in preparation for da vinci.
Glassman, Deanna; White, Lee; Lewis, Andrew; King, Hawkeye; Clarke, Alicia; Glassman, Thomas; Comstock, Bryan; Hannaford, Blake; Lendvay, Thomas S
2014-01-01
The rapid adoption of robotic assisted surgery challenges the pace at which adequate robotic training can occur due to access limitations to the da Vinci robot. Thirty medical students completed a randomized controlled trial evaluating whether the Raven robot could be used as an alternative training tool for the Fundamentals of Laparoscopic Surgery (FLS) block transfer task on the da Vinci robot. Two groups, one trained on the da Vinci and one trained on the Raven, were tested on a criterion FLS block transfer task on the da Vinci. After robotic FLS block transfer proficiency training there was no statistically significant difference between path length (p=0.39) and economy of motion scores (p=0.06) between the two groups, but those trained on the da Vinci did have faster task times (p=0.01). These results provide evidence for the value of using the Raven robot for training prior to using the da Vinci surgical system for similar tasks.
Inducing self-selected human engagement in robotic locomotion training.
Collins, Steven H; Jackson, Rachel W
2013-06-01
Stroke leads to severe mobility impairments for millions of individuals each year. Functional outcomes can be improved through manual treadmill therapy, but high costs limit patient exposure and, thereby, outcomes. Robotic gait training could increase the viable duration and frequency of training sessions, but robotic approaches employed thus far have been less effective than manual therapy. These shortcomings may relate to subconscious energy-minimizing drives, which might cause patients to engage less actively in therapy when provided with corrective robotic assistance. We have devised a new method for gait rehabilitation that harnesses, rather than fights, least-effort tendencies. Therapeutic goals, such as increased use of the paretic limb, are made easier than the patient's nominal gait through selective assistance from a robotic platform. We performed a pilot test on a healthy subject (N = 1) in which altered self-selected stride length was induced using a tethered robotic ankle-foot orthosis. The subject first walked on a treadmill while wearing the orthosis with and without assistance at unaltered and voluntarily altered stride length. Voluntarily increasing stride length by 5% increased metabolic energy cost by 4%. Robotic assistance decreased energy cost at both unaltered and voluntarily increased stride lengths, by 6% and 8% respectively. We then performed a test in which the robotic system continually monitored stride length and provided more assistance if the subject's stride length approached a target increase. This adaptive assistance protocol caused the subject to slowly adjust their gait patterns towards the target, leading to a 4% increase in stride length. Metabolic energy consumption was simultaneously reduced by 5%. These results suggest that selective-assistance protocols based on targets relevant to rehabilitation might lead patients to self-select desirable gait patterns during robotic gait training sessions, possibly facilitating better adherence and outcomes.
Towards more effective robotic gait training for stroke rehabilitation: a review
2012-01-01
Background Stroke is the most common cause of disability in the developed world and can severely degrade walking function. Robot-driven gait therapy can provide assistance to patients during training and offers a number of advantages over other forms of therapy. These potential benefits do not, however, seem to have been fully realised as of yet in clinical practice. Objectives This review determines ways in which robot-driven gait technology could be improved in order to achieve better outcomes in gait rehabilitation. Methods The literature on gait impairments caused by stroke is reviewed, followed by research detailing the different pathways to recovery. The outcomes of clinical trials investigating robot-driven gait therapy are then examined. Finally, an analysis of the literature focused on the technical features of the robot-based devices is presented. This review thus combines both clinical and technical aspects in order to determine the routes by which robot-driven gait therapy could be further developed. Conclusions Active subject participation in robot-driven gait therapy is vital to many of the potential recovery pathways and is therefore an important feature of gait training. Higher levels of subject participation and challenge could be promoted through designs with a high emphasis on robotic transparency and sufficient degrees of freedom to allow other aspects of gait such as balance to be incorporated. PMID:22953989
Singh, Hardeep; Unger, Janelle; Zariffa, José; Pakosh, Maureen; Jaglal, Susan; Craven, B Catharine; Musselman, Kristin E
2018-01-15
Abstact Purpose: To provide an overview of the feasibility and outcomes of robotic-assisted upper extremity training for individuals with cervical spinal cord injury (SCI), and to identify gaps in current research and articulate future research directions. A systematic search was conducted using Medline, Embase, PsycINFO, CCTR, CDSR, CINAHL and PubMed on June 7, 2017. Search terms included 3 themes: (1) robotics; (2) SCI; (3) upper extremity. Studies using robots for upper extremity rehabilitation among individuals with cervical SCI were included. Identified articles were independently reviewed by two researchers and compared to pre-specified criteria. Disagreements regarding article inclusion were resolved through discussion. The modified Downs and Black checklist was used to assess article quality. Participant characteristics, study and intervention details, training outcomes, robot features, study limitations and recommendations for future studies were abstracted from included articles. Twelve articles (one randomized clinical trial, six case series, five case studies) met the inclusion criteria. Five robots were exoskeletons and three were end-effectors. Sample sizes ranged from 1 to 17 subjects. Articles had variable quality, with quality scores ranging from 8 to 20. Studies had a low internal validity primarily from lack of blinding or a control group. Individuals with mild-moderate impairments showed the greatest improvements on body structure/function and performance-level measures. This review is limited by the small number of articles, low-sample sizes and the diversity of devices and their associated training protocols, and outcome measures. Preliminary evidence suggests robot-assisted interventions are safe, feasible and can reduce active assistance provided by therapists. Implications for rehabilitation Robot-assisted upper extremity training for individuals with cervical spinal cord injury is safe, feasible and can reduce hands-on assistance provided by therapists. Future research in robotics rehabilitation with individuals with spinal cord injury is needed to determine the optimal device and training protocol as well as effectiveness.
Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J; Lum, Peter S
2014-05-01
Individuals with chronic stroke often have long-lasting upper extremity impairments that impede function during activities of daily living. Rehabilitation robotics have shown promise in improving arm function, but current systems do not allow realistic training of activities of daily living. We have incorporated the ARMin III and HandSOME device into a novel robotic therapy modality that provides functional training of reach and grasp tasks. To compare the effects of equal doses of robotic and conventional therapy in individuals with chronic stroke. Subjects were randomized to 12 hours of robotic or conventional therapy and then crossed over to the other therapy type after a 1-month washout period. Twelve moderate to severely impaired individuals with chronic stroke were enrolled, and 10 completed the study. Across the 3-month study period, subjects showed significant improvements in the Fugl-Meyer (P = .013) and Box and Blocks tests (P = .028). The robotic intervention produced significantly greater improvements in the Action Research Arm Test than conventional therapy (P = .033). Gains in the Box and Blocks test from conventional therapy were larger than from robotic therapy in subjects who received conventional therapy after robotic therapy (P = .044). Data suggest that robotic therapy can elicit improvements in arm function that are distinct from conventional therapy and supplements conventional methods to improve outcomes. Results from this pilot study should be confirmed in a larger study.
Wu, Ming; Kim, Janis; Arora, Pooja; Gaebler-Spira, Deborah J; Zhang, Yunhui
2017-11-01
The aim of the study was to determine whether applying an assistance force to the pelvis and legs during treadmill training can improve walking function in children with cerebral palsy. Twenty-three children with cerebral palsy were randomly assigned to the robotic or treadmill only group. For participants who were assigned to the robotic group, a controlled force was applied to the pelvis and legs during treadmill walking. For participants who were assigned to the treadmill only group, manual assistance was provided as needed. Each participant trained 3 times/wk for 6 wks. Outcome measures included walking speed, 6-min walking distance, and clinical assessment of motor function, which were evaluated before, after training, and 8 wks after the end of training, and were compared between two groups. Significant increases in walking speed and 6-min walking distance were observed after robotic training (P = 0.03), but no significant change was observed after treadmill training only. A greater increase in 6-min walking distance was observed after robotic training than that after treadmill only training (P = 0.01). Applying a controlled force to the pelvis and legs, for facilitating weight-shift and leg swing, respectively, during treadmill training may improve walking speed and endurance in children with cerebral palsy. Complete the self-assessment activity and evaluation online at http://www.physiatry.org/JournalCME CME OBJECTIVES: Upon completion of this article, the reader should be able to: (1) discuss the importance of physical activity at the participation level (sports programs) for children with cerebral palsy; (2) contrast the changes in walking ability and endurance for children in GMFCS level I, II and III following sports programs; and (3) identify the impact of higher frequency of sports program attendance over time on walking ability. Advanced ACCREDITATION: The Association of Academic Physiatrists is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians.The Association of Academic Physiatrists designates this Journal-based CME activity for a maximum of 0.5 AMA PRA Category 1 Credit(s)™. Physicians should only claim credit commensurate with the extent of their participation in the activity.
Hu, Chunying; Huang, Qiuchen; Yu, Lili; Ye, Miao
2016-07-01
[Purpose] The purpose of this study was to examine the immediate effects of robot-assisted therapy on functional activity level after anterior cruciate ligament reconstruction. [Subjects and Methods] Participants included 10 patients (8 males and 2 females) following anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy and treadmill exercise on different days. The Timed Up-and-Go test, Functional Reach Test, surface electromyography of the vastus lateralis and vastus medialis, and maximal extensor strength of isokinetic movement of the knee joint were evaluated in both groups before and after the experiment. [Results] The results for the Timed Up-and-Go Test and the 10-Meter Walk Test improved in the robot-assisted rehabilitation group. Surface electromyography of the vastus medialis muscle showed significant increases in maximum and average discharge after the intervention. [Conclusion] The results suggest that walking ability and muscle strength can be improved by robotic training.
Improved walking ability with wearable robot-assisted training in patients suffering chronic stroke.
Li, Lifang; Ding, Li; Chen, Na; Mao, Yurong; Huang, Dongfeng; Li, Le
2015-01-01
Wearable robotic devices provide safe and intensive rehabilitation, enabling repeated motions for motor function recovery in stroke patients. The aim of this small case series was to demonstrate the training effects of a three-week robotic leg orthosis, and to investigate possible mechanisms of the sensory-motor alterations and improvements by using gait analysis and EMG. Three survivors of chronic strokes participated in robot-assisted gait therapy for three weeks. EMG signals from the rectus femoris (RF), tibialis anterior (TA), biceps femoris (BF), and medial gastrocnemius (MG), as well as kinetics and kinematics data of the lower limb, were recorded before and after the training. The normalized root mean squared (RMS) values of the muscles, the joint moments, joint angles, and the results of two clinical scales (Berg Balance scale, BBS, and the lower extremity subscale of Fugl-Meyer assessment, LE-FMA) were used for analysis. All participants experienced improved balance and functional performances and increased BBS and LE-FMA scores. The EMG results showed there was an increase of the normalized RMS values of the MG and BF on the affected side. Additionally, EMG activities of the agonist and antagonist pair (i.e. RF and BF) appeared to return to similar levels after training. The peak moment of hip flexor, knee extensor, and plantar flexor, which all contributed to push-off power, were found to have increased after training. In summary, the three-week training period using the wearable RLO improved the three participants' gait performance by regaining push-off power and improved muscle activation and walking speed.
Deploying the ODIS robot in Iraq and Afghanistan
NASA Astrophysics Data System (ADS)
Smuda, Bill; Schoenherr, Edward; Andrusz, Henry; Gerhart, Grant
2005-05-01
The wars in Iraq and Afghanistan have shown the importance of robotic technology as a force multiplier and a tool for moving soldiers out of harms way. Situations on the ground make soldiers performing checkpoint operations easy targets for snipers and suicide bombers. Robotics technology reduces risk to soldiers and other personnel at checkpoints. Early user involvement in innovative and aggressive development and acquisition strategies are the key to moving robotic and associated technology into the hands of the user. This paper updates activity associated with rapid development of the Omni-Directional Inspection System (ODIS) robot for under vehicle inspection and reports on our field experience with robotics in Iraq and Afghanistan. In February of 2004, two TARDEC Engineers departed for a mission to Iraq and Afghanistan with ten ODIS Robots. Six robots were deployed in the Green Zone in Baghdad. Two Robots were deployed at Kandahar Army Airfield and two were deployed at Bagram Army Airfield in Afghanistan. The TARDEC Engineers who performed this mission trained the soldiers and provided initial on site support. They also trained Exponent employees assigned to the Rapid Equipping Force in ODIS repair. We will discuss our initial deployment, lessons learned and future plans.
Li, Chong; Rusák, Zoltán; Horváth, Imre; Ji, Linhong
2014-12-01
Efficacious stroke rehabilitation depends not only on patients' medical treatment but also on their motivation and engagement during rehabilitation exercises. Although traditional rehabilitation exercises are often mundane, technology-assisted upper-limb robotic training can provide engaging and task-oriented training in a natural environment. The factors that influence engagement, however, are not fully understood. This paper therefore studies the relationship between engagement and muscle activities as well as the influencing factors of engagement. To this end, an experiment was conducted using a robotic upper limb rehabilitation system with healthy individuals in three training exercises: (a) a traditional exercise, which is typically used for training the grasping function, (b) a tracking exercise, currently used in robot-assisted stroke patient rehabilitation for fine motor movement, and (c) a video game exercise, which is a proliferating approach of robot-assisted rehabilitation enabling high-level active engagement of stroke patients. These exercises differ not only in the characteristics of the motion that they use but also in their method of triggering engagement. To measure the level of engagement, we used facial expressions, motion analysis of the arm movements, and electromyography. The results show that (a) the video game exercise could engage the participants for a longer period than the other two exercises, (b) the engagement level decreased when the participants became too familiar with the exercises, and (c) analysis of normalized root mean square in electromyographic data indicated that muscle activities were more intense when the participants are engaged. This study shows that several sub-factors on engagement, such as versatility of feedback, cognitive tasks, and competitiveness, may influence engagement more than the others. To maintain a high level of engagement, the rehabilitation system needs to be adaptive, providing different exercises to engage the participants.
Crew/Robot Coordinated Planetary EVA Operations at a Lunar Base Analog Site
NASA Technical Reports Server (NTRS)
Diftler, M. A.; Ambrose, R. O.; Bluethmann, W. J.; Delgado, F. J.; Herrera, E.; Kosmo, J. J.; Janoiko, B. A.; Wilcox, B. H.; Townsend, J. A.; Matthews, J. B.;
2007-01-01
Under the direction of NASA's Exploration Technology Development Program, robots and space suited subjects from several NASA centers recently completed a very successful demonstration of coordinated activities indicative of base camp operations on the lunar surface. For these activities, NASA chose a site near Meteor Crater, Arizona close to where Apollo Astronauts previously trained. The main scenario demonstrated crew returning from a planetary EVA (extra-vehicular activity) to a temporary base camp and entering a pressurized rover compartment while robots performed tasks in preparation for the next EVA. Scenario tasks included: rover operations under direct human control and autonomous modes, crew ingress and egress activities, autonomous robotic payload removal and stowage operations under both local control and remote control from Houston, and autonomous robotic navigation and inspection. In addition to the main scenario, participants had an opportunity to explore additional robotic operations: hill climbing, maneuvering heaving loads, gathering geo-logical samples, drilling, and tether operations. In this analog environment, the suited subjects and robots experienced high levels of dust, rough terrain, and harsh lighting.
Clinical application of a modular ankle robot for stroke rehabilitation.
Forrester, Larry W; Roy, Anindo; Goodman, Ronald N; Rietschel, Jeremy; Barton, Joseph E; Krebs, Hermano Igo; Macko, Richard F
2013-01-01
Advances in our understanding of neuroplasticity and motor learning post-stroke are now being leveraged with the use of robotics technology to enhance physical rehabilitation strategies. Major advances have been made with upper extremity robotics, which have been tested for efficacy in multi-site trials across the subacute and chronic phases of stroke. In contrast, use of lower extremity robotics to promote locomotor re-learning has been more recent and presents unique challenges by virtue of the complex multi-segmental mechanics of gait. Here we review a programmatic effort to develop and apply the concept of joint-specific modular robotics to the paretic ankle as a means to improve underlying impairments in distal motor control that may have a significant impact on gait biomechanics and balance. An impedance controlled ankle robot module (anklebot) is described as a platform to test the idea that a modular approach can be used to modify training and measure the time profile of treatment response. Pilot studies using seated visuomotor anklebot training with chronic patients are reviewed, along with results from initial efforts to evaluate the anklebot's utility as a clinical tool for assessing intrinsic ankle stiffness. The review includes a brief discussion of future directions for using the seated anklebot training in the earliest phases of sub-acute therapy, and to incorporate neurophysiological measures of cerebro-cortical activity as a means to reveal underlying mechanistic processes of motor learning and brain plasticity associated with robotic training. Finally we conclude with an initial control systems strategy for utilizing the anklebot as a gait training tool that includes integrating an Internal Model-based adaptive controller to both accommodate individual deficit severities and adapt to changes in patient performance.
Clinical application of a modular ankle robot for stroke rehabilitation
Forrester, Larry W.; Roy, Anindo; Goodman, Ronald N.; Rietschel, Jeremy; Barton, Joseph E.; Krebs, Hermano Igo; Macko, Richard F.
2015-01-01
Background Advances in our understanding of neuroplasticity and motor learning post-stroke are now being leveraged with the use of robotics technology to enhance physical rehabilitation strategies. Major advances have been made with upper extremity robotics, which have been tested for efficacy in multi-site trials across the subacute and chronic phases of stroke. In contrast, use of lower extremity robotics to promote locomotor re-learning has been more recent and presents unique challenges by virtue of the complex multi-segmental mechanics of gait. Objectives Here we review a programmatic effort to develop and apply the concept of joint-specific modular robotics to the paretic ankle as a means to improve underlying impairments in distal motor control that may have a significant impact on gait biomechanics and balance. Methods An impedance controlled ankle robot module (anklebot) is described as a platform to test the idea that a modular approach can be used to modify training and measure the time profile of treatment response. Results Pilot studies using seated visuomotor anklebot training with chronic patients are reviewed, along with results from initial efforts to evaluate the anklebot's utility as a clinical tool for assessing intrinsic ankle stiffness. The review includes a brief discussion of future directions for using the seated anklebot training in the earliest phases of sub-acute therapy, and to incorporate neurophysiological measures of cerebro-cortical activity as a means to reveal underlying mechanistic processes of motor learning and brain plasticity associated with robotic training. Conclusions Finally we conclude with an initial control systems strategy for utilizing the anklebot as a gait training tool that includes integrating an Internal Model-based adaptive controller to both accommodate individual deficit severities and adapt to changes in patient performance. PMID:23949045
A simple highly efficient non invasive EMG-based HMI.
Vitiello, N; Olcese, U; Oddo, C M; Carpaneto, J; Micera, S; Carrozza, M C; Dario, P
2006-01-01
Muscle activity recorded non-invasively is sufficient to control a mobile robot if it is used in combination with an algorithm for its asynchronous analysis. In this paper, we show that several subjects successfully can control the movements of a robot in a structured environment made up of six rooms by contracting two different muscles using a simple algorithm. After a small training period, subjects were able to control the robot with performances comparable to those achieved manually controlling the robot.
Survey of robotic surgery training in obstetrics and gynecology residency.
Gobern, Joseph M; Novak, Christopher M; Lockrow, Ernest G
2011-01-01
To examine the status of resident training in robotic surgery in obstetrics and gynecology programs in the United States, an online survey was emailed to residency program directors of 247 accredited programs identified through the Accreditation Council for Graduate Medical Education website. Eighty-three of 247 program directors responded, representing a 34% response rate. Robotic surgical systems for gynecologic procedures were used at 65 (78%) institutions. Robotic surgery training was part of residency curriculum at 48 (58%) residency programs. Half of respondents were undecided on training effectiveness. Most program directors believed the role of robotic surgery would increase and play a more integral role in gynecologic surgery. Robotic surgery was widely reported in residency training hospitals with limited availability of effective resident training. Robotic surgery training in obstetrics and gynecology residency needs further assessment and may benefit from a structured curriculum. Published by Elsevier Inc.
Flinn, Nancy A; Smith, Jennifer L; Tripp, Christopher J; White, Matthew W
2009-01-01
The objective of the study was to examine the results of robotic therapy in a single client. A 48-year-old female client 15 months post-stroke, with right hemiparesis, received robotic therapy as an outpatient in a large Midwestern rehabilitation hospital. Robotic therapy was provided three times a week for 6 weeks. Robotic therapy consisted of goal-directed, robotic-aided reaching tasks to exercise the hemiparetic shoulder and elbow. No other therapeutic intervention for the affected upper extremity was provided during the study or 3 months follow-up period. The outcome measures included the Fugl-Meyer, graded Wolf motor function test (GWMFT), motor activity log, active range of motion and Canadian occupational performance measure. The participant made gains in active movement; performance; and satisfaction of functional tasks, GWMFT and functional use. Limitations involved in this study relate to the generalizability of the sample size, effect of medications, expense of robotic technologies and the impact of aphasia. Future research should incorporate functional use training along with robotic therapy.
Krishnan, Chandramouli; Kotsapouikis, Despina; Dhaher, Yasin Y; Rymer, William Z
2013-06-01
To test the feasibility of patient-cooperative robotic gait training for improving locomotor function of a chronic stroke survivor with severe lower-extremity motor impairments. Single-subject crossover design. Performed in a controlled laboratory setting. A 62-year-old man with right temporal lobe ischemic stroke was recruited for this study. The baseline lower-extremity Fugl-Meyer score of the subject was 10 on a scale of 34, which represented severe impairment in the paretic leg. However, the subject had a good ambulation level (community walker with the aid of a stick cane and ankle-foot orthosis) and showed no signs of sensory or cognitive impairments. The subject underwent 12 sessions (3 times per week for 4wk) of conventional robotic training with the Lokomat, where the robot provided full assistance to leg movements while walking, followed by 12 sessions (3 times per week for 4wk) of patient-cooperative robotic control training, where the robot provided minimal guidance to leg movements during walking. Clinical outcomes were evaluated before the start of the intervention, immediately after 4 weeks of conventional robotic training, and immediately after 4 weeks of cooperative control robotic training. These included: (1) self-selected and fast walking speed, (2) 6-minute walk test, (3) Timed Up & Go test, and (4) lower-extremity Fugl-Meyer score. Results showed that clinical outcomes changed minimally after full guidance robotic training, but improved considerably after 4 weeks of reduced guidance robotic training. The findings from this case study suggest that cooperative control robotic training is superior to conventional robotic training and is a feasible option to restoring locomotor function in ambulatory stroke survivors with severe motor impairments. A larger trial is needed to verify the efficacy of this advanced robotic control strategy in facilitating gait recovery after stroke. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Ladenheim, Barbara; Altenburger, Peter; Cardinal, Ryan; Monterroso, Linda; Dierks, Tracy; Mast, Joelle; Krebs, Hermano Igo
2013-01-01
Robot assisted upper extremity therapy has been shown to be effective in adult stroke patients and in children with cerebral palsy (CP) and other acquired brain injuries (ABI). The patient's active involvement is a factor in its efficacy. However, this demands focused attention during training sessions, which can be a challenge for children. To compare results of training requiring two different levels of focused attention. Differences in short term performance and retention of gains as a function of training protocol as measured by the Fugl-Meyer (FM) were predicted. Thirty-one children with CP or ABI were randomly divided into two groups. All received 16 one hour sessions of robot-assisted therapy (twice a week for 8 weeks) where they moved a robot handle to direct a cursor on the screen toward designated targets. One group had targets presented sequentially in clockwise fashion, the other presented in random order. Thus, one group could anticipate the position of each target, the other could not. Both groups showed significant functional improvement after therapy, but no significant difference between groups was observed. Assist-as-needed robotic training is effective in children with CP or ABI with small non-significant differences attributed to attentional demand.
Basic Operational Robotics Instructional System
NASA Technical Reports Server (NTRS)
Todd, Brian Keith; Fischer, James; Falgout, Jane; Schweers, John
2013-01-01
The Basic Operational Robotics Instructional System (BORIS) is a six-degree-of-freedom rotational robotic manipulator system simulation used for training of fundamental robotics concepts, with in-line shoulder, offset elbow, and offset wrist. BORIS is used to provide generic robotics training to aerospace professionals including flight crews, flight controllers, and robotics instructors. It uses forward kinematic and inverse kinematic algorithms to simulate joint and end-effector motion, combined with a multibody dynamics model, moving-object contact model, and X-Windows based graphical user interfaces, coordinated in the Trick Simulation modeling environment. The motivation for development of BORIS was the need for a generic system for basic robotics training. Before BORIS, introductory robotics training was done with either the SRMS (Shuttle Remote Manipulator System) or SSRMS (Space Station Remote Manipulator System) simulations. The unique construction of each of these systems required some specialized training that distracted students from the ideas and goals of the basic robotics instruction.
Virtual reality surgical simulators- a prerequisite for robotic surgery.
Rajanbabu, Anupama; Drudi, Laura; Lau, Susie; Press, Joshua Z; Gotlieb, Walter H
2014-06-01
The field of computer assisted minimally invasive surgery is rapidly expanding worldwide, including in India. With more hospitals in India contemplating the acquisition of a robotic platform, training of robotic surgeons is becoming essential. Virtual reality simulators can be used for surgeons to become acquainted with the robotic console prior to live surgery. Our aim was to evaluate the amount of simulator training required before a surgeon first operates on the da Vinci® Surgical System. Simulations were conducted on the Intuitive Surgical's da Vinci® Robot Skill Simulator using the software obtained from Mimic Technologies. Participants included attending staff surgeons experienced in robotic surgery and novices. A set of seven activities were chosen for each participant. Based on the mean exercise score from the first attempt, staff surgeons outperformed the novices in all exercises. However, the difference in score between the staff and the novices decreased after the participants repeated the exercises and by the sixth attempt most of the novices obtained similar scores to the staff, suggesting that this might be at present the minimum set of repetitions indicated (or required) prior to performing life robotic surgery.
Modular Ankle Robotics Training in Early Sub-Acute Stroke: A Randomized Controlled Pilot Study
Forrester, Larry W.; Roy, Anindo; Krywonis, Amanda; Kehs, Glenn; Krebs, Hermano Igo; Macko, Richard F.
2014-01-01
Background Modular lower extremity (LE) robotics may offer a valuable avenue for restoring neuromotor control after hemiparetic stroke. Prior studies show that visually-guided and visually-evoked practice with an ankle robot (anklebot) improves paretic ankle motor control that translates into improved overground walking. Objective Assess the feasibility and efficacy of daily anklebot training during early sub-acute hospitalization post-stroke. Methods Thirty-four inpatients from a stroke unit were randomly assigned to anklebot (N=18) or passive manual stretching (N=16) treatments. All suffered a first stroke with residual hemiparesis (ankle manual muscle test grade 1/5 to 4/5), and at least trace muscle activation in plantar- or dorsiflexion. Anklebot training employed an “assist-as-needed” approach during > 200 volitional targeted paretic ankle movements, with difficulty adjusted to active range of motion and success rate. Stretching included >200 daily mobilizations in these same ranges. All sessions lasted 1 hour and assessments were not blinded. Results Both groups walked faster at discharge, however the robot group improved more in percent change of temporal symmetry (p=0.032) and also of step length symmetry (p=0.038), with longer nonparetic step lengths in the robot (133%) vs. stretching (31%) groups. Paretic ankle control improved in the robot group, with increased peak (p≤ 0.001) and mean (p≤ 0.01) angular speeds, and increased movement smoothness (p≤ 0.01). There were no adverse events. Conclusion Though limited by small sample size and restricted entry criteria, our findings suggest that modular lower extremity robotics during early sub-acute hospitalization is well tolerated and improves ankle motor control and gait patterning. PMID:24515923
Robotic Exploration of Moon and Mars: Thematic Education Approach
NASA Technical Reports Server (NTRS)
Allen, J S.; Tobola, K. W.; Lowes, L. L.; Betrue, R.
2008-01-01
Safe, sustained, affordable human and robotic exploration of the Moon, Mars, and beyond is a major NASA goal. Robotic exploration of the Moon and Mars will help pave the way for an expanded human presence in our solar system. To help share the robotic exploration role in the Vision for Space Exploration with classrooms, informal education groups, and the public, our team researched and consolidated the thematic story components and associated education activities into a useful education materials set for educators. We developed the set of materials for a workshop combining NASA Science Mission Directorate and Exploration Systems Mission Directorate engineering, science, and technology to train informal educators on education activities that support the robotic exploration themes. A major focus is on the use of robotic spacecraft and instruments to explore and prepare for the human exploration of the Moon and Mars.
Survey on Robot-Assisted Surgical Techniques Utilization in US Pediatric Surgery Fellowships.
Maizlin, Ilan I; Shroyer, Michelle C; Yu, David C; Martin, Colin A; Chen, Mike K; Russell, Robert T
2017-02-01
Robotic technology has transformed both practice and education in many adult surgical specialties; no standardized training guidelines in pediatric surgery currently exist. The purpose of our study was to assess the prevalence of robotic procedures and extent of robotic surgery education in US pediatric surgery fellowships. A deidentified survey measured utilization of the robot, perception on the utility of the robot, and its incorporation in training among the program directors of Accreditation Council for Graduate Medical Education (ACGME) pediatric surgery fellowships in the United States. Forty-one of the 47 fellowship programs (87%) responded to the survey. While 67% of respondents indicated the presence of a robot in their facility, only 26% reported its utilizing in their surgical practice. Among programs not utilizing the robot, most common reasons provided were lack of clear supportive evidence, increased intraoperative time, and incompatibility of instrument size to pediatric patients. While 58% of program directors believe that there is a future role for robotic surgery in children, only 18% indicated that robotic training should play a part in pediatric surgery education. Consequently, while over 66% of survey respondents received training in robot-assisted surgical technique, only 29% of fellows receive robot-assisted training during their fellowship. A majority of fellowships have access to a robot, but few utilize the technology in their current practice or as part of training. Further investigation is required into both the technology's potential benefits in the pediatric population and its role in pediatric surgery training.
Myoelectrically controlled wrist robot for stroke rehabilitation
2013-01-01
Background Robot-assisted rehabilitation is an advanced new technology in stroke rehabilitation to provide intensive training. Post-stroke motor recovery depends on active rehabilitation by voluntary participation of patient’s paretic motor system as early as possible in order to promote reorganization of brain. However, voluntary residual motor efforts to the affected limb have not been involved enough in most robot-assisted rehabilitation for patients after stroke. The objective of this study is to evaluate the feasibility of robot-assisted rehabilitation using myoelectric control on upper limb motor recovery. Methods In the present study, an exoskeleton-type rehabilitation robotic system was designed to provide voluntarily controlled assisted torque to the affected wrist. Voluntary intention was involved by using the residual surface electromyography (EMG) from flexor carpi radialis(FCR) and extensor carpi radialis (ECR)on the affected limb to control the mechanical assistance provided by the robotic system during wrist flexion and extension in a 20-session training. The system also applied constant resistant torque to the affected wrist during the training. Sixteen subjects after stroke had been recruited for evaluating the tracking performance and therapeutical effects of myoelectrically controlled robotic system. Results With the myoelectrically-controlled assistive torque, stroke survivors could reach a larger range of motion with a significant decrease in the EMG signal from the agonist muscles. The stroke survivors could be trained in the unreached range with their voluntary residual EMG on the paretic side. After 20-session rehabilitation training, there was a non-significant increase in the range of motion and a significant decrease in the root mean square error (RMSE) between the actual wrist angle and target angle. Significant improvements also could be found in muscle strength and clinical scales. Conclusions These results indicate that robot-aided therapy with voluntary participation of patient’s paretic motor system using myoelectric control might have positive effect on upper limb motor recovery. PMID:23758925
Robot-assisted laparoscopic skills development: formal versus informal training.
Benson, Aaron D; Kramer, Brandan A; Boehler, Margaret; Schwind, Cathy J; Schwartz, Bradley F
2010-08-01
The learning curve for robotic surgery is not completely defined, and ideal training components have not yet been identified. We attempted to determine whether skill development would be accelerated with formal, organized instruction in robotic surgical techniques versus informal practice alone. Forty-three medical students naive to robotic surgery were randomized into two groups and tested on three tasks using the robotic platform. Between the testing sessions, the students were given equally timed practice sessions. The formal training group participated in an organized, formal training session with instruction from an attending robotic surgeon, whereas the informal training group participated in an equally timed unstructured practice session with the robot. The results were compared based on technical score and time to completion of each task. There was no difference between groups in prepractice testing for any task. In postpractice testing, there was no difference between groups for the ring transfer tasks. However, for the suture placement and knot-tying task, the technical score of the formal training group was significantly better than that of the informal training group (p < 0.001), yet time to completion was not different. Although formal training may not be necessary for basic skills, formal instruction for more advanced skills, such as suture placement and knot tying, is important in developing skills needed for effective robotic surgery. These findings may be important in formulating potential skills labs or training courses for robotic surgery.
Sports Training Support Method by Self-Coaching with Humanoid Robot
NASA Astrophysics Data System (ADS)
Toyama, S.; Ikeda, F.; Yasaka, T.
2016-09-01
This paper proposes a new training support method called self-coaching with humanoid robots. In the proposed method, two small size inexpensive humanoid robots are used because of their availability. One robot called target robot reproduces motion of a target player and another robot called reference robot reproduces motion of an expert player. The target player can recognize a target technique from the reference robot and his/her inadequate skill from the target robot. Modifying the motion of the target robot as self-coaching, the target player could get advanced cognition. Some experimental results show some possibility as the new training method and some issues of the self-coaching interface program as a future work.
Taveggia, Giovanni; Borboni, Alberto; Mulé, Chiara; Negrini, Stefano
2016-01-01
Robot gait training has the potential to increase the effectiveness of walking therapy. Clinical outcomes after robotic training are often not superior to conventional therapy. We evaluated the effectiveness of a robot training compared with a usual gait training physiotherapy during a standardized rehabilitation protocol in inpatient participants with poststroke hemiparesis. This was a randomized double-blind clinical trial in a postacute physical and rehabilitation medicine hospital. Twenty-eight patients, 39.3% women (72±6 years), with hemiparesis (<6 months after stroke) receiving a conventional treatment according to the Bobath approach were assigned randomly to an experimental or a control intervention of robot gait training to improve walking (five sessions a week for 5 weeks). Outcome measures included the 6-min walk test, the 10 m walk test, Functional Independence Measure, SF-36 physical functioning and the Tinetti scale. Outcomes were collected at baseline, immediately following the intervention period and 3 months following the end of the intervention. The experimental group showed a significant increase in functional independence and gait speed (10 m walk test) at the end of the treatment and follow-up, higher than the minimal detectable change. The control group showed a significant increase in the gait endurance (6-min walk test) at the follow-up, higher than the minimal detectable change. Both treatments were effective in the improvement of gait performances, although the statistical analysis of functional independence showed a significant improvement in the experimental group, indicating possible advantages during generic activities of daily living compared with overground treatment. PMID:26512928
NASA Technical Reports Server (NTRS)
Porter, Derrick
2014-01-01
The Mission Operations Directorate (MOD) is responsible for the training, planning and performance of all U.S. manned operations in space. Within this directorate all responsibilities are divided up into divisions. The EVA, Robotics & Crew Systems Operations Division performs ground operations and trains astronauts to carry out some of the more "high action" procedures in space. For example they orchestrate procedures like EVAs, or ExtraVehicular Activities (spacewalks), and robotics operations external to the International Space Station (ISS). The robotics branch of this division is responsible for the use of the Mobile Servicing System (MSS). This system is a combination of two robotic mechanisms and a series of equipment used to transport them on the ISS. The MSS is used to capture and position visiting vehicles, transport astronauts during EVAs, and perform external maintenance tasks on the ISS. This branch consists of two groups which are responsible for crew training and flight controlling, respectively. My first co-op tour took place Fall 2013. During this time I was given the opportunity to work in the robotics operations branch of the Mission Operations Directorate at NASA's Johnson Space Center. I was given a variety of tasks that encompassed, at a base level, all the aspects of the branch.
Residency Training in Robotic General Surgery: A Survey of Program Directors
George, Lea C.; O'Neill, Rebecca
2018-01-01
Objective Robotic surgery continues to expand in minimally invasive surgery; however, the literature is insufficient to understand the current training process for general surgery residents. Therefore, the objectives of this study were to identify the current approach to and perspectives on robotic surgery training. Methods An electronic survey was distributed to general surgery program directors identified by the Accreditation Council for Graduate Medical Education website. Multiple choice and open-ended questions regarding current practices and opinions on robotic surgery training in general surgery residency programs were used. Results 20 program directors were surveyed, a majority being from medium-sized programs (4–7 graduating residents per year). Most respondents (73.68%) had a formal robotic surgery curriculum at their institution, with 63.16% incorporating simulation training. Approximately half of the respondents believe that more time should be dedicated to robotic surgery training (52.63%), with simulation training prior to console use (84.21%). About two-thirds of the respondents (63.16%) believe that a formal robotic surgery curriculum should be established as a part of general surgery residency, with more than half believing that exposure should occur in postgraduate year one (55%). Conclusion A formal robotics curriculum with simulation training and early surgical exposure for general surgery residents should be given consideration in surgical residency training. PMID:29854454
Residency Training in Robotic General Surgery: A Survey of Program Directors.
George, Lea C; O'Neill, Rebecca; Merchant, Aziz M
2018-01-01
Robotic surgery continues to expand in minimally invasive surgery; however, the literature is insufficient to understand the current training process for general surgery residents. Therefore, the objectives of this study were to identify the current approach to and perspectives on robotic surgery training. An electronic survey was distributed to general surgery program directors identified by the Accreditation Council for Graduate Medical Education website. Multiple choice and open-ended questions regarding current practices and opinions on robotic surgery training in general surgery residency programs were used. 20 program directors were surveyed, a majority being from medium-sized programs (4-7 graduating residents per year). Most respondents (73.68%) had a formal robotic surgery curriculum at their institution, with 63.16% incorporating simulation training. Approximately half of the respondents believe that more time should be dedicated to robotic surgery training (52.63%), with simulation training prior to console use (84.21%). About two-thirds of the respondents (63.16%) believe that a formal robotic surgery curriculum should be established as a part of general surgery residency, with more than half believing that exposure should occur in postgraduate year one (55%). A formal robotics curriculum with simulation training and early surgical exposure for general surgery residents should be given consideration in surgical residency training.
Modulation of weight off-loading level over body-weight supported locomotion training.
Wang, Ping; Low, K H; Lim, Peter A C; McGregor, A H
2011-01-01
With the evolution of robotic systems to facilitate overground walking rehabilitation, it is important to understand the effect of robotic-aided body-weight supported loading on lower limb muscle activity, if we are to optimize neuromotor recovery. To achieve this objective, we have collected and studied electromyography (EMG) data from key muscles in the lower extremity from healthy subjects walking over a wide range of body-weight off-loading levels as provided by a bespoke gait robot. By examining the impact of body-weight off-loading, it was found that muscle activation patterns were sensitive to the level of off-loading. In addition, a large off-loading might introduce disturbance of muscle activation pattern, led to a wider range of motion in terms of dorsiflexion/plantarflexion. Therefore, any future overground training machine should be enhanced to exclude unnecessary effect of body off-loading in securing the sustaining upright posture and providing assist-as-needed BWS over gait rehabilitation. © 2011 IEEE
NASA Technical Reports Server (NTRS)
Hollars, M. G.; Cannon, R. H., Jr.; Alexander, H. L.; Morse, D. F.
1987-01-01
The Stanford University Aerospace Robotics Laboratory is actively developing and experimentally testing advanced robot control strategies for space robotic applications. Early experiments focused on control of very lightweight one-link manipulators and other flexible structures. The results are being extended to position and force control of mini-manipulators attached to flexible manipulators and multilink manipulators with flexible drive trains. Experimental results show that end-point sensing and careful dynamic modeling or adaptive control are key to the success of these control strategies. Free-flying space robot simulators that operate on an air cushion table have been built to test control strategies in which the dynamics of the base of the robot and the payload are important.
Caregiver and social assistant robot for rehabilitation and coaching for the elderly.
Pérez, P J; Garcia-Zapirain, B; Mendez-Zorrilla, A
2015-01-01
Socially assistive robotics (SAR) has been a major field of investigation during the last decade and, as it develops, the groups the technology can be applied to and all ways in which these can be assisted are rapidly increasing. The main objective is to design and develop a complete robotic agent, so that it performs physical and mental activities for elderly people to maintain their healthy life habits and, as a final result, improve their quality of life. LEGO Mindstorms NXT® robot's unique capacity for adaptability and engaging its users to develop coaching activities and assistive rehabilitation for the elderly. Such activities will aim to enhance healthy habits and provide training in physical and mental rehabilitation. The robot is attached to an iPod Touch that acts as its interface. The robot has been tested by a voluntary group of residents, also from that retirement home. Results in the variables of the questionnaire show scores above 4 points out of 5 for all the categories. Based on the tests, an easy to use Robot is prepared to deliver basic coaching for physical activities as proposed by the client, the staff of La Misericordia, who confirmed their satisfaction regarding this aspect.
Whitehurst, Sabrina V; Lockrow, Ernest G; Lendvay, Thomas S; Propst, Anthony M; Dunlow, Susan G; Rosemeyer, Christopher J; Gobern, Joseph M; White, Lee W; Skinner, Anna; Buller, Jerome L
2015-01-01
To compare the efficacy of simulation-based training between the Mimic dV- Trainer and traditional dry lab da Vinci robot training. A prospective randomized study analyzing the performance of 20 robotics-naive participants. Participants were enrolled in an online da Vinci Intuitive Surgical didactic training module, followed by training in use of the da Vinci standard surgical robot. Spatial ability tests were performed as well. Participants were randomly assigned to 1 of 2 training conditions: performance of 3 Fundamentals of Laparoscopic Surgery dry lab tasks using the da Vinci or performance of 4 dV-Trainer tasks. Participants in both groups performed all tasks to empirically establish proficiency criterion. Participants then performed the transfer task, a cystotomy closure using the daVinci robot on a live animal (swine) model. The performance of robotic tasks was blindly assessed by a panel of experienced surgeons using objective tracking data and using the validated Global Evaluative Assessment of Robotic Surgery (GEARS), a structured assessment tool. No statistically significant difference in surgeon performance was found between the 2 training conditions, dV-Trainer and da Vinci robot. Analysis of a 95% confidence interval for the difference in means (-0.803 to 0.543) indicated that the 2 methods are unlikely to differ to an extent that would be clinically meaningful. Based on the results of this study, a curriculum on the dV- Trainer was shown to be comparable to traditional da Vinci robot training. Therefore, we have identified that training on a virtual reality system may be an alternative to live animal training for future robotic surgeons. Published by Elsevier Inc.
Retention of laparoscopic and robotic skills among medical students: a randomized controlled trial.
Orlando, Megan S; Thomaier, Lauren; Abernethy, Melinda G; Chen, Chi Chiung Grace
2017-08-01
Although simulation training beneficially contributes to traditional surgical training, there are less objective data on simulation skills retention. To investigate the retention of laparoscopic and robotic skills after simulation training. We present the second stage of a randomized single-blinded controlled trial in which 40 simulation-naïve medical students were randomly assigned to practice peg transfer tasks on either laparoscopic (N = 20, Fundamentals of Laparoscopic Surgery, Venture Technologies Inc., Waltham, MA) or robotic (N = 20, dV-Trainer, Mimic, Seattle, WA) platforms. In the first stage, two expert surgeons evaluated participants on both tasks before (Stage 1: Baseline) and immediately after training (Stage 1: Post-training) using a modified validated global rating scale of laparoscopic and robotic operative performance. In Stage 2, participants were evaluated on both tasks 11-20 weeks after training. Of the 40 students who participated in Stage 1, 23 (11 laparoscopic and 12 robotic) underwent repeat evaluation. During Stage 2, there were no significant differences between groups in objective or subjective measures for the laparoscopic task. Laparoscopic-trained participants' performances on the laparoscopic task were improved during Stage 2 compared to baseline measured by time to task completion, but not by the modified global rating scale. During the robotic task, the robotic-trained group demonstrated superior economy of motion (p = .017), Tissue Handling (p = .020), and fewer errors (p = .018) compared to the laparoscopic-trained group. Robotic skills acquisition from baseline with no significant deterioration as measured by modified global rating scale scores was observed among robotic-trained participants during Stage 2. Robotic skills acquired through simulation appear to be better maintained than laparoscopic simulation skills. This study is registered on ClinicalTrials.gov (NCT02370407).
Effect of Error Augmentation on Brain Activation and Motor Learning of a Complex Locomotor Task
Marchal-Crespo, Laura; Michels, Lars; Jaeger, Lukas; López-Olóriz, Jorge; Riener, Robert
2017-01-01
Up to date, the functional gains obtained after robot-aided gait rehabilitation training are limited. Error augmenting strategies have a great potential to enhance motor learning of simple motor tasks. However, little is known about the effect of these error modulating strategies on complex tasks, such as relearning to walk after a neurologic accident. Additionally, neuroimaging evaluation of brain regions involved in learning processes could provide valuable information on behavioral outcomes. We investigated the effect of robotic training strategies that augment errors—error amplification and random force disturbance—and training without perturbations on brain activation and motor learning of a complex locomotor task. Thirty-four healthy subjects performed the experiment with a robotic stepper (MARCOS) in a 1.5 T MR scanner. The task consisted in tracking a Lissajous figure presented on a display by coordinating the legs in a gait-like movement pattern. Behavioral results showed that training without perturbations enhanced motor learning in initially less skilled subjects, while error amplification benefited better-skilled subjects. Training with error amplification, however, hampered transfer of learning. Randomly disturbing forces induced learning and promoted transfer in all subjects, probably because the unexpected forces increased subjects' attention. Functional MRI revealed main effects of training strategy and skill level during training. A main effect of training strategy was seen in brain regions typically associated with motor control and learning, such as, the basal ganglia, cerebellum, intraparietal sulcus, and angular gyrus. Especially, random disturbance and no perturbation lead to stronger brain activation in similar brain regions than error amplification. Skill-level related effects were observed in the IPS, in parts of the superior parietal lobe (SPL), i.e., precuneus, and temporal cortex. These neuroimaging findings indicate that gait-like motor learning depends on interplay between subcortical, cerebellar, and fronto-parietal brain regions. An interesting observation was the low activation observed in the brain's reward system after training with error amplification compared to training without perturbations. Our results suggest that to enhance learning of a locomotor task, errors should be augmented based on subjects' skill level. The impacts of these strategies on motor learning, brain activation, and motivation in neurological patients need further investigation. PMID:29021739
Phé, Véronique; Cattarino, Susanna; Parra, Jérôme; Bitker, Marc-Olivier; Ambrogi, Vanina; Vaessen, Christophe; Rouprêt, Morgan
2017-06-01
The utility of the virtual-reality robotic simulator in training programmes has not been clearly evaluated. Our aim was to evaluate the impact of a virtual-reality robotic simulator-training programme on basic surgical skills. A simulator-training programme in robotic surgery, using the da Vinci Skills Simulator, was evaluated in a population including junior and seasoned surgeons, and non-physicians. Their performances on robotic dots and suturing-skin pod platforms before and after virtual-simulation training were rated anonymously by surgeons experienced in robotics. 39 participants were enrolled: 14 medical students and residents in surgery, 14 seasoned surgeons, 11 non-physicians. Junior and seasoned surgeons' performances on platforms were not significantly improved after virtual-reality robotic simulation in any of the skill domains, in contrast to non-physicians. The benefits of virtual-reality simulator training on several tasks to basic skills in robotic surgery were not obvious among surgeons in our initial and early experience with the simulator. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Stein, Joel; Narendran, Kailas; McBean, John; Krebs, Kathryn; Hughes, Richard
2007-04-01
Robot-assisted exercise shows promise as a means of providing exercise therapy for weakness that results from stroke or other neurological conditions. Exoskeletal or "wearable" robots can, in principle, provide therapeutic exercise and/or function as powered orthoses to help compensate for chronic weakness. We describe a novel electromyography (EMG)-controlled exoskeletal robotic brace for the elbow (the active joint brace) and the results of a pilot study conducted using this brace for exercise training in individuals with chronic hemiparesis after stroke. Eight stroke survivors with severe chronic hemiparesis were enrolled in this pilot study. One subject withdrew from the study because of scheduling conflicts. A second subject was unable to participate in the training protocol because of insufficient surface EMG activity to control the active joint brace. The six remaining subjects each underwent 18 hrs of exercise training using the device for a period of 6 wks. Outcome measures included the upper-extremity component of the Fugl-Meyer scale and the modified Ashworth scale of muscle hypertonicity. Analysis revealed that the mean upper-extremity component of the Fugl-Meyer scale increased from 15.5 (SD 3.88) to 19 (SD 3.95) (P = 0.04) at the conclusion of training for the six subjects who completed training. Combined (summated) modified Ashworth scale for the elbow flexors and extensors improved from 4.67 (+/-1.2 SD) to 2.33 (+/-0.653 SD) (P = 0.009) and improved for the entire upper limb as well. All subjects tolerated the device, and no complications occurred. EMG-controlled powered elbow orthoses can be successfully controlled by severely impaired hemiparetic stroke survivors. This technique shows promise as a new modality for assisted exercise training after stroke.
Perez, Manuela; Perrenot, Cyril; Tran, Nguyen; Hossu, Gabriela; Felblinger, Jacques; Hubert, Jacques
2013-09-01
Robotic surgery has witnessed a huge expansion. Robotic simulators have proved to be of major interest in training. Some authors have suggested that prior experience in micro-surgery could improve robotic surgery training. To test micro-surgery as a new approach in training, we proposed a prospective study comparing the surgical performance of micro-surgeons with that of general surgeons on a robotic simulator. 49 surgeons were enrolled; 11 in the micro-surgery group (MSG); 38 n the control group (CG). Performance was evaluated based on five dV-Trainer® exercises. MSG achieved better results for all exercises including exercises requiring visual evaluation of force feed-back, economy of motion, instrument force and position. These results show that experience in micro-surgery could significantly improve surgeons' abilities and their performance in robotic training. So, as micro-surgery practice is relatively cheap, it could be easily included in basic robotic surgery training. Copyright © 2013 John Wiley & Sons, Ltd.
Laubacher, Marco; Perret, Claudio; Hunt, Kenneth J
2015-01-01
Robotics-assisted tilt-table (RTT) technology allows neurological rehabilitation therapy to be started early thus alleviating some secondary complications of prolonged bed rest. This study assessed the feasibility of a novel work-rate-guided RTT approach for cardiopulmonary training and assessment in patients with incomplete spinal cord injury (iSCI). Three representative subjects with iSCI at three distinct stages of primary rehabilitation completed an incremental exercise test (IET) and a constant load test (CLT) on a RTT augmented with integrated leg-force and position measurement and visual work rate feedback. Feasibility assessment focused on: (i) implementation, (ii) limited efficacy testing, (iii) acceptability. (i) All subjects were able follow the work rate target profile by adapting their volitional leg effort. (ii) During the IETs, peak oxygen uptake above rest was 304, 467 and 1378 ml/min and peak heart rate (HR) was 46, 32 and 65 beats/min above rest (subjects A, B and C, respectively). During the CLTs, steady-state oxygen uptake increased by 42%, 38% and 162% and HR by 12%, 20% and 29%. (iii) All exercise tests were tolerated well. The novel work-rate guided RTT intervention is deemed feasible for cardiopulmonary training and assessment in patients with iSCI: substantial cardiopulmonary responses were observed and the approach was found to be tolerable and implementable. Implications for Rehabilitation Work-rate guided robotics-assisted tilt-table technology is deemed feasible for cardiopulmonary assessment and training in patients with incomplete spinal cord injury. Robotics-assisted tilt-tables might be a good way to start with an active rehabilitation as early as possible after a spinal cord injury. During training with robotics-assisted devices the active participation of the patients is crucial to strain the cardiopulmonary system and hence gain from the training.
Proficiency training on a virtual reality robotic surgical skills curriculum.
Bric, Justin; Connolly, Michael; Kastenmeier, Andrew; Goldblatt, Matthew; Gould, Jon C
2014-12-01
The clinical application of robotic surgery is increasing. The skills necessary to perform robotic surgery are unique from those required in open and laparoscopic surgery. A validated laparoscopic surgical skills curriculum (Fundamentals of Laparoscopic Surgery or FLS™) has transformed the way surgeons acquire laparoscopic skills. There is a need for a similar skills training and assessment tool for robotic surgery. Our research group previously developed and validated a robotic training curriculum in a virtual reality (VR) simulator. We hypothesized that novice robotic surgeons could achieve proficiency levels defined by more experienced robotic surgeons on the VR robotic curriculum, and that this would result in improved performance on the actual daVinci Surgical System™. 25 medical students with no prior robotic surgery experience were recruited. Prior to VR training, subjects performed 2 FLS tasks 3 times each (Peg Transfer, Intracorporeal Knot Tying) using the daVinci Surgical System™ docked to a video trainer box. Task performance for the FLS tasks was scored objectively. Subjects then practiced on the VR simulator (daVinci Skills Simulator) until proficiency levels on all 5 tasks were achieved before completing a post-training assessment of the 2 FLS tasks on the daVinci Surgical System™ in the video trainer box. All subjects to complete the study (1 dropped out) reached proficiency levels on all VR tasks in an average of 71 (± 21.7) attempts, accumulating 164.3 (± 55.7) minutes of console training time. There was a significant improvement in performance on the robotic FLS tasks following completion of the VR training curriculum. Novice robotic surgeons are able to attain proficiency levels on a VR simulator. This leads to improved performance in the daVinci surgical platform on simulated tasks. Training to proficiency on a VR robotic surgery simulator is an efficient and viable method for acquiring robotic surgical skills.
Teaching Human Poses Interactively to a Social Robot
Gonzalez-Pacheco, Victor; Malfaz, Maria; Fernandez, Fernando; Salichs, Miguel A.
2013-01-01
The main activity of social robots is to interact with people. In order to do that, the robot must be able to understand what the user is saying or doing. Typically, this capability consists of pre-programmed behaviors or is acquired through controlled learning processes, which are executed before the social interaction begins. This paper presents a software architecture that enables a robot to learn poses in a similar way as people do. That is, hearing its teacher's explanations and acquiring new knowledge in real time. The architecture leans on two main components: an RGB-D (Red-, Green-, Blue- Depth) -based visual system, which gathers the user examples, and an Automatic Speech Recognition (ASR) system, which processes the speech describing those examples. The robot is able to naturally learn the poses the teacher is showing to it by maintaining a natural interaction with the teacher. We evaluate our system with 24 users who teach the robot a predetermined set of poses. The experimental results show that, with a few training examples, the system reaches high accuracy and robustness. This method shows how to combine data from the visual and auditory systems for the acquisition of new knowledge in a natural manner. Such a natural way of training enables robots to learn from users, even if they are not experts in robotics. PMID:24048336
Teaching human poses interactively to a social robot.
Gonzalez-Pacheco, Victor; Malfaz, Maria; Fernandez, Fernando; Salichs, Miguel A
2013-09-17
The main activity of social robots is to interact with people. In order to do that, the robot must be able to understand what the user is saying or doing. Typically, this capability consists of pre-programmed behaviors or is acquired through controlled learning processes, which are executed before the social interaction begins. This paper presents a software architecture that enables a robot to learn poses in a similar way as people do. That is, hearing its teacher's explanations and acquiring new knowledge in real time. The architecture leans on two main components: an RGB-D (Red-, Green-, Blue- Depth) -based visual system, which gathers the user examples, and an Automatic Speech Recognition (ASR) system, which processes the speech describing those examples. The robot is able to naturally learn the poses the teacher is showing to it by maintaining a natural interaction with the teacher. We evaluate our system with 24 users who teach the robot a predetermined set of poses. The experimental results show that, with a few training examples, the system reaches high accuracy and robustness. This method shows how to combine data from the visual and auditory systems for the acquisition of new knowledge in a natural manner. Such a natural way of training enables robots to learn from users, even if they are not experts in robotics.
Robotics Technician Training at Macomb Community College.
ERIC Educational Resources Information Center
Lynch, Edward J.
Approved in 1979, the robotics technician training program at Macomb County Community College (MCC) in Warren (Michigan) provides students with training in hydraulics and electronics as well as with hands-on training in the area of robotics. Furthermore, the program faculty includes individuals with work experience in electronics, fluid power, and…
A cable-driven locomotor training system for restoration of gait in human SCI.
Wu, Ming; Hornby, T George; Landry, Jill M; Roth, Heidi; Schmit, Brian D
2011-02-01
A novel cable-driven robotic locomotor training system was developed to provide compliant assistance/resistance forces to the legs during treadmill training in patients with incomplete spinal cord injury (SCI). Eleven subjects with incomplete SCI were recruited to participate in two experiments to test the feasibility of the robotic gait training system. Specifically, 10 subjects participated in one experimental session to test the characteristics of the robotic gait training system and one subject participated in repeated testing sessions over 8 weeks with the robotic device to test improvements in locomotor function. Limb kinematics were recorded in one experiment to evaluate the system characteristics of the cable-driven locomotor trainer and the overground gait speed and 6 min walking distance were evaluated at pre, 4 and 8 weeks post treadmill training of a single subject as well. The results indicated that the cable driven robotic gait training system improved the kinematic performance of the leg during treadmill walking and had no significant impact on the variability of lower leg trajectory, suggesting a high backdrivability of the cable system. In addition, results from a patient with incomplete SCI indicated that prolonged robotic gait training using the cable robot improved overground gait speed. Results from this study suggested that a cable driven robotic gait training system is effective in improving leg kinematic performance, yet allows variability of gait kinematics. Thus, it seems feasible to improve the locomotor function in human SCI using this cable driven robotic system, warranting testing with a larger group of patients. Copyright © 2010 Elsevier B.V. All rights reserved.
Milot, Marie-Hélène; Spencer, Steven J.; Chan, Vicky; Allington, James P.; Klein, Julius; Chou, Cathy; Pearson-Fuhrhop, Kristin; Bobrow, James E.; Reinkensmeyer, David J.; Cramer, Steven C.
2014-01-01
Background Robotic training can help improve function of a paretic limb following a stroke, but individuals respond differently to the training. A predictor of functional gains might improve the ability to select those individuals more likely to benefit from robot based therapy. Studies evaluating predictors of functional improvement after a robotic training are scarce. One study has found that white matter tract integrity predicts functional gains following a robotic training of the hand and wrist. Objective Determine the predictive ability of behavioral and brain measures to improve selection of individuals for robotic training. Methods Twenty subjects with chronic stroke participated in an 8-week course of robotic exoskeletal training for the arm. Before training, a clinical evaluation, fMRI, diffusion tensor imaging, and transcranial magnetic stimulation (TMS) were each measured as predictors. Final functional gain was defined as change in the Box and Block Test (BBT). Measures significant in bivariate analysis were fed into a multivariate linear regression model. Results Training was associated with an average gain of 6±5 blocks on the BBT (p<0.0001). Bivariate analysis revealed that lower baseline motor evoked potential (MEP) amplitude on TMS, and lower laterality M1 index on fMRI each significantly correlated with greater BBT change. In the multivariate linear regression analysis, baseline MEP magnitude was the only measure that remained significant. Conclusion Subjects with lower baseline MEP magnitude benefited the most from robotic training of the affected arm. These subjects might have reserve remaining for the training to boost corticospinal excitability, translating into functional gains. PMID:24642382
Vanmulken, D A M M; Spooren, A I F; Bongers, H M H; Seelen, H A M
2015-07-01
Prospective multiple case study. To test (1) the feasibility of haptic robot technology (Haptic Master (HM)) use to improve arm-hand function (AHF) and arm-hand skill performance (AHSP) in persons with a cervical spinal cord injury (C-SCI), (2) inventory participants' motivation and expectation to work with the robot technology used and (3) to descriptively report the results in individual cases. Rehabilitation Centre. Five C-SCI patients were trained for 6 weeks, 3 days per week, 60 min per day. Therapists filled out the Usefulness, Satisfaction and Ease-of-use questionnaire (USE). The Intrinsic Motivational Inventory (IMI) and credibility and expectancy questionnaire (CEQ) were filled out by participants. Performance at activity level was gauged using the Van Lieshout test for AHF in Tetraplegia and the Spinal Cord Independence Measure. Function level was gauged using muscle strength testing and the International Classification for Surgery of the Hand in Tetraplegia. As to the feasibility of the application of haptic robot technology, the mean USE score was 65%. Mean IMI and CEQ results were 67% and 60%, respectively. Participants were motivated to train with the HM. All participants rated credibility higher than expectations regarding the improvement. In the current patients, little progress was demonstrated at the International Classification of Functioning, Disability and Health function and the activity level. It is feasible to train C-SCI persons with the HM. Therapists report that working with the HM is easy to learn and easy to perform. Usability of the HM may be improved. Further research is needed to assess in which group of C-SCI and at which stage of rehabilitation HM training may be most beneficial.
Low-Cost Educational Robotics Applied to Physics Teaching in Brazil
ERIC Educational Resources Information Center
Souza, Marcos A. M.; Duarte, José R. R.
2015-01-01
In this paper, we propose some of the strategies and methodologies for teaching high-school physics topics through an educational robotics show. This exhibition was part of a set of actions promoted by a Brazilian government program of incentive for teaching activities, whose primary focus is the training of teachers, the improvement of teaching…
2018-01-01
Objective To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. Methods A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Results Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Conclusion Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients. PMID:29765872
Kim, Sang Beom; Lee, Kyeong Woo; Lee, Jong Hwa; Lee, Sook Joung; Park, Jin Gee; Park, Joo Won
2018-04-01
To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients.
Hussain, Irfan; Santarnecchi, Emiliano; Leo, Andrea; Ricciardi, Emiliano; Rossi, Simone; Prattichizzo, Domenico
2017-07-01
The Supernumerary robotic limbs are a recently introduced class of wearable robots that, differently from traditional prostheses and exoskeletons, aim at adding extra effectors (i.e., arms, legs, or fingers) to the human user, rather than substituting or enhancing the natural ones. However, it is still undefined whether the use of supernumerary robotic limbs could specifically lead to neural modifications in brain dynamics. The illusion of owning the part of body has been already proven in many experimental observations, such as those relying on multisensory integration (e.g., rubber hand illusion), prosthesis and even on virtual reality. In this paper we present a description of a novel magnetic compatible supernumerary robotic finger together with preliminary observations from two functional magnetic resonance imaging (fMRI) experiments, in which brain activity was measured before and after a period of training with the robotic device, and during the use of the novel MRI-compatible version of the supernumerary robotic finger. Results showed that the usage of the MR-compatible robotic finger is safe and does not produce artifacts on MRI images. Moreover, the training with the supernumerary robotic finger recruits a network of motor-related cortical regions (i.e. primary and supplementary motor areas), hence the same motor network of a fully physiological voluntary motor gestures.
McWhinney, S R; Tremblay, A; Boe, S G; Bardouille, T
2018-02-01
Neurofeedback training teaches individuals to modulate brain activity by providing real-time feedback and can be used for brain-computer interface control. The present study aimed to optimize training by maximizing engagement through goal-oriented task design. Participants were shown either a visual display or a robot, where each was manipulated using motor imagery (MI)-related electroencephalography signals. Those with the robot were instructed to quickly navigate grid spaces, as the potential for goal-oriented design to strengthen learning was central to our investigation. Both groups were hypothesized to show increased magnitude of these signals across 10 sessions, with the greatest gains being seen in those navigating the robot due to increased engagement. Participants demonstrated the predicted increase in magnitude, with no differentiation between hemispheres. Participants navigating the robot showed stronger left-hand MI increases than those with the computer display. This is likely due to success being reliant on maintaining strong MI-related signals. While older participants showed stronger signals in early sessions, this trend later reversed, suggesting greater natural proficiency but reduced flexibility. These results demonstrate capacity for modulating neurofeedback using MI over a series of training sessions, using tasks of varied design. Importantly, the more goal-oriented robot control task resulted in greater improvements.
Robot-assisted gait training in multiple sclerosis patients: a randomized trial.
Schwartz, Isabella; Sajin, Anna; Moreh, Elior; Fisher, Iris; Neeb, Martin; Forest, Adina; Vaknin-Dembinsky, Adi; Karusis, Dimitrios; Meiner, Zeev
2012-06-01
Preservation of locomotor activity in multiple sclerosis (MS) patients is of utmost importance. Robotic-assisted body weight-supported treadmill training is a promising method to improve gait functions in neurologically impaired patients, although its effectiveness in MS patients is still unknown. To compare the effectiveness of robot-assisted gait training (RAGT) with that of conventional walking treatment (CWT) on gait and generalized functions in a group of stable MS patients. A prospective randomized controlled trial of 12 sessions of RAGT or CWT in MS patients of EDSS score 5-7. Primary outcome measures were gait parameters and the secondary outcomes were functional and quality of life parameters. All tests were performed at baseline, 3 and 6 months post-treatment by a blinded rater. Fifteen and 17 patients were randomly allocated to RAGT and CWT, respectively. Both groups were comparable at baseline in all parameters. As compared with baseline, although some gait parameters improved significantly following the treatment at each time point there was no difference between the groups. Both FIM and EDSS scores improved significantly post-treatment with no difference between the groups. At 6 months, most gait and functional parameters had returned to baseline. Robot-assisted gait training is feasible and safe and may be an effective additional therapeutic option in MS patients with severe walking disabilities.
NASA Astrophysics Data System (ADS)
Fels, Meike; Bauer, Robert; Gharabaghi, Alireza
2015-08-01
Objective. Novel rehabilitation strategies apply robot-assisted exercises and neurofeedback tasks to facilitate intensive motor training. We aimed to disentangle task-specific and subject-related contributions to the perceived workload of these interventions and the related cortical activation patterns. Approach. We assessed the perceived workload with the NASA Task Load Index in twenty-one subjects who were exposed to two different feedback tasks in a cross-over design: (i) brain-robot interface (BRI) with haptic/proprioceptive feedback of sensorimotor oscillations related to motor imagery, and (ii) control of neuromuscular activity with feedback of the electromyography (EMG) of the same hand. We also used electroencephalography to examine the cortical activation patterns beforehand in resting state and during the training session of each task. Main results. The workload profile of BRI feedback differed from EMG feedback and was particularly characterized by the experience of frustration. The frustration level was highly correlated across tasks, suggesting subject-related relevance of this workload component. Those subjects who were specifically challenged by the respective tasks could be detected by an interhemispheric alpha-band network in resting state before the training and by their sensorimotor theta-band activation pattern during the exercise. Significance. Neurophysiological profiles in resting state and during the exercise may provide task-independent workload markers for monitoring and matching participants’ ability and task difficulty of neurofeedback interventions.
Motor modules in robot-aided walking
2012-01-01
Background It is hypothesized that locomotion is achieved by means of rhythm generating networks (central pattern generators) and muscle activation generating networks. This modular organization can be partly identified from the analysis of the muscular activity by means of factorization algorithms. The activity of rhythm generating networks is described by activation signals whilst the muscle intervention generating network is represented by motor modules (muscle synergies). In this study, we extend the analysis of modular organization of walking to the case of robot-aided locomotion, at varying speed and body weight support level. Methods Non Negative Matrix Factorization was applied on surface electromyographic signals of 8 lower limb muscles of healthy subjects walking in gait robotic trainer at different walking velocities (1 to 3km/h) and levels of body weight support (0 to 30%). Results The muscular activity of volunteers could be described by low dimensionality (4 modules), as for overground walking. Moreover, the activation signals during robot-aided walking were bursts of activation timed at specific phases of the gait cycle, underlying an impulsive controller, as also observed in overground walking. This modular organization was consistent across the investigated speeds, body weight support level, and subjects. Conclusions These results indicate that walking in a Lokomat robotic trainer is achieved by similar motor modules and activation signals as overground walking and thus supports the use of robotic training for re-establishing natural walking patterns. PMID:23043818
Milot, Marie-Hélène; Spencer, Steven J; Chan, Vicky; Allington, James P; Klein, Julius; Chou, Cathy; Pearson-Fuhrhop, Kristin; Bobrow, James E; Reinkensmeyer, David J; Cramer, Steven C
2014-01-01
Robotic training can help improve function of a paretic limb following a stroke, but individuals respond differently to the training. A predictor of functional gains might improve the ability to select those individuals more likely to benefit from robot-based therapy. Studies evaluating predictors of functional improvement after a robotic training are scarce. One study has found that white matter tract integrity predicts functional gains following a robotic training of the hand and wrist. Objective. To determine the predictive ability of behavioral and brain measures in order to improve selection of individuals for robotic training. Twenty subjects with chronic stroke participated in an 8-week course of robotic exoskeletal training for the arm. Before training, a clinical evaluation, functional magnetic resonance imaging (fMRI), diffusion tensor imaging, and transcranial magnetic stimulation (TMS) were each measured as predictors. Final functional gain was defined as change in the Box and Block Test (BBT). Measures significant in bivariate analysis were fed into a multivariate linear regression model. Training was associated with an average gain of 6 ± 5 blocks on the BBT (P < .0001). Bivariate analysis revealed that lower baseline motor-evoked potential (MEP) amplitude on TMS, and lower laterality M1 index on fMRI each significantly correlated with greater BBT change. In the multivariate linear regression analysis, baseline MEP magnitude was the only measure that remained significant. Subjects with lower baseline MEP magnitude benefited the most from robotic training of the affected arm. These subjects might have reserve remaining for the training to boost corticospinal excitability, translating into functional gains. © The Author(s) 2014.
Virtual Reality Simulator Systems in Robotic Surgical Training.
Mangano, Alberto; Gheza, Federico; Giulianotti, Pier Cristoforo
2018-06-01
The number of robotic surgical procedures has been increasing worldwide. It is important to maximize the cost-effectiveness of robotic surgical training and safely reduce the time needed for trainees to reach proficiency. The use of preliminary lab training in robotic skills is a good strategy for the rapid acquisition of further, standardized robotic skills. Such training can be done either by using a simulator or by exercises in a dry or wet lab. While the use of an actual robotic surgical system for training may be problematic (high cost, lack of availability), virtual reality (VR) simulators can overcome many of these obstacles. However, there is still a lack of standardization. Although VR training systems have improved, they cannot yet replace experience in a wet lab. In particular, simulated scenarios are not yet close enough to a real operative experience. Indeed, there is a difference between technical skills (i.e., mechanical ability to perform a simulated task) and surgical competence (i.e., ability to perform a real surgical operation). Thus, while a VR simulator can replace a dry lab, it cannot yet replace training in a wet lab or operative training in actual patients. However, in the near future, it is expected that VR surgical simulators will be able to provide total reality simulation and replace training in a wet lab. More research is needed to produce more wide-ranging, trans-specialty robotic curricula.
Smith, James Andrew; Jivraj, Jamil; Wong, Ronnie; Yang, Victor
2016-04-01
This review provides an examination of contemporary neurosurgical robots and the developments that led to them. Improvements in localization, microsurgery and minimally invasive surgery have made robotic neurosurgery viable, as seen by the success of platforms such as the CyberKnife and neuromate. Neurosurgical robots can now perform specific surgical tasks such as skull-base drilling and craniotomies, as well as pedicle screw and cochlear electrode insertions. Growth trends in neurosurgical robotics are likely to continue but may be tempered by concerns over recent surgical robot recalls, commercially-driven surgeon training, and studies that show operational costs for surgical robotic procedures are often higher than traditional surgical methods. We point out that addressing performance issues related to navigation-related registration is an active area of research and will aid in improving overall robot neurosurgery performance and associated costs.
Retention of fundamental surgical skills learned in robot-assisted surgery.
Suh, Irene H; Mukherjee, Mukul; Shah, Bhavin C; Oleynikov, Dmitry; Siu, Ka-Chun
2012-12-01
Evaluation of the learning curve for robotic surgery has shown reduced errors and decreased task completion and training times compared with regular laparoscopic surgery. However, most training evaluations of robotic surgery have only addressed short-term retention after the completion of training. Our goal was to investigate the amount of surgical skills retained after 3 months of training with the da Vinci™ Surgical System. Seven medical students without any surgical experience were recruited. Participants were trained with a 4-day training program of robotic surgical skills and underwent a series of retention tests at 1 day, 1 week, 1 month, and 3 months post-training. Data analysis included time to task completion, speed, distance traveled, and movement curvature by the instrument tip. Performance of the participants was graded using the modified Objective Structured Assessment of Technical Skills (OSATS) for robotic surgery. Participants filled out a survey after each training session by answering a set of questions. Time to task completion and the movement curvature was decreased from pre- to post-training and the performance was retained at all the corresponding retention periods: 1 day, 1 week, 1 month, and 3 months. The modified OSATS showed improvement from pre-test to post-test and this improvement was maintained during all the retention periods. Participants increased in self-confidence and mastery in performing robotic surgical tasks after training. Our novel comprehensive training program improved robot-assisted surgical performance and learning. All trainees retained their fundamental surgical skills for 3 months after receiving the training program.
Robotics in reproductive surgery: strengths and limitations.
Catenacci, M; Flyckt, R L; Falcone, T
2011-09-01
Minimally invasive surgical techniques are becoming increasingly common in gynecologic surgery. However, traditional laparoscopy can be challenging. A robotic surgical system gives several advantages over traditional laparoscopy and has been incorporated into reproductive gynecological surgeries. The objective of this article is to review recent publications on robotically-assisted laparoscopy for reproductive surgery. Recent clinical research supports robotic surgery as resulting in less post-operative pain, shorter hospital stays, faster return to normal activities, and decreased blood loss. Reproductive outcomes appear similar to alternative approaches. Drawbacks of robotic surgery include longer operating room times, the need for specialized training, and increased cost. Larger prospective studies comparing robotic approaches with laparoscopy and conventional open surgery have been initiated and information regarding long-term outcomes after robotic surgery will be important in determining the ultimate utility of these procedures. Copyright © 2011 Elsevier Ltd. All rights reserved.
Design and implementation of a training strategy in chronic stroke with an arm robotic exoskeleton.
Frisoli, Antonio; Sotgiu, Edoardo; Procopio, Caterina; Bergamasco, Massimo; Rossi, Bruno; Chisari, Carmelo
2011-01-01
The distinguishing features of active exoskeletons are the capability of guiding arm movement at the level of the full kinematic chain of the human arm, and training full 3D spatial movements. We have specifically developed a PD sliding mode control for upper limb rehabilitation with gain scheduling for providing "assistance as needed", according to the force capability of the patient, and an automatic measurement of the impaired arm joint torques, to evaluate the hypertonia associated to the movement during the execution of the training exercise. Two different training tasks in Virtual Reality were devised, that make use of the above control, and allow to make a performance based evaluation of patient's motor status. The PERCRO L-Exos (Light-Exoskeleton) was used to evaluate the proposed algorithms and training exercises in two clinical case studies of patients with chronic stroke, that performed 6 weeks of robotic assisted training. Clinical evaluation (Fugl-Meyer Scale, Modified Ashworth Scale, Bimanual Activity Test) was conducted before and after treatment and compared to the scores and the quantitative indices, such as task time, position/joint error and resistance torques, associated to the training exercises. © 2011 IEEE
Moore, Lee J; Wilson, Mark R; Waine, Elizabeth; Masters, Rich S W; McGrath, John S; Vine, Samuel J
2015-03-01
Technical surgical skills are said to be acquired quicker on a robotic rather than laparoscopic platform. However, research examining this proposition is scarce. Thus, this study aimed to compare the performance and learning curves of novices acquiring skills using a robotic or laparoscopic system, and to examine if any learning advantages were maintained over time and transferred to more difficult and stressful tasks. Forty novice participants were randomly assigned to either a robotic- or laparoscopic-trained group. Following one baseline trial on a ball pick-and-drop task, participants performed 50 learning trials. Participants then completed an immediate retention trial and a transfer trial on a two-instrument rope-threading task. One month later, participants performed a delayed retention trial and a stressful multi-tasking trial. The results revealed that the robotic-trained group completed the ball pick-and-drop task more quickly and accurately than the laparoscopic-trained group across baseline, immediate retention, and delayed retention trials. Furthermore, the robotic-trained group displayed a shorter learning curve for accuracy. The robotic-trained group also performed the more complex rope-threading and stressful multi-tasking transfer trials better. Finally, in the multi-tasking trial, the robotic-trained group made fewer tone counting errors. The results highlight the benefits of using robotic technology for the acquisition of technical surgical skills.
Robotic colorectal surgery: previous laparoscopic colorectal experience is not essential.
Sian, Tanvir Singh; Tierney, G M; Park, H; Lund, J N; Speake, W J; Hurst, N G; Al Chalabi, H; Smith, K J; Tou, S
2018-06-01
A background in minimally invasive colorectal surgery (MICS) has been thought to be essential prior to robotic-assisted colorectal surgery (RACS). Our aim was to determine whether MICS is essential prior to starting RACS training based on results from our initial experience with RACS. Two surgeons from our centre received robotic training through the European Academy of Robotic Colorectal Surgery (EARCS). One surgeon had no prior formal MICS training. We reviewed the first 30 consecutive robotic colorectal procedures from a prospectively maintained database between November 2014 and January 2016 at our institution. Fourteen patients were male. Median age was 64.5 years (range 36-82) and BMI was 27.5 (range 20-32.5). Twelve procedures (40%) were performed by the non-MICS-trained surgeon: ten high anterior resections (one conversion), one low anterior resection and one abdomino-perineal resection of rectum (APER). The MICS-trained surgeon performed nine high and four low anterior resections, one APER and in addition three right hemicolectomies and one abdominal suture rectopexy. There were no intra-operative complications and two patients required re-operation. Median post-operative stay was five days (range 1-26). There were two 30-day re-admissions. All oncological resections had clear margins and median node harvest was 18 (range 9-39). Our case series demonstrates that a background in MICS is not essential prior to starting RACS training. Not having prior MICS training should not discourage surgeons from considering applying for a robotic training programme. Safe and successful robotic colorectal services can be established after completing a formal structured robotic training programme.
Lee, So Young; Jeon, Young Tae; Kim, Bo Ryun; Han, Eun Young
2017-01-01
Abstract Rationale: Spasticity is a major complication after stroke, and botulinumtoxin A (BoNT-A) injection is commonly used to manage focal spasticity. However, it is uncertain whether BoNT-A can improve voluntary motor control or activities of daily living function of paretic upper limbs. This study investigated whether BoNT-A injection combined with robot-assisted upper limb therapy improves voluntary motor control or functions of upper limbs after stroke. Patient concerns: Two subacute stroke patients were transferred to the Department of Rehabilitation. Diagnoses: Patients demonstrated spasticity in the upper extremity on the affected side. Interventions: BoNT-A was injected into the paretic muscles of the shoulder, arm, and forearm of the 2 patients at the subacute stage. Conventional rehabilitation therapy and robot-assisted upper limb training were performed during the rehabilitation period. Outcomes: Manual dexterity, grip strength, muscle tone, and activities of daily living function were improved after multidisciplinary rehabilitation treatment. Lessons: BoNT-A injection in combination with multidisciplinary rehabilitation treatment, including robot-assisted arm training, should be recommended for subacute spastic stroke patients to enhance appropriate motor recovery. PMID:29390585
Varoqui, Deborah; Niu, Xun; Mirbagheri, Mehdi M
2014-03-31
In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities-characterized by increases in the over-ground walking speed and endurance-is generally observed in patients. To better understand the mechanisms underlying these improvements, we studied the effects of Lokomat training on impaired ankle voluntary movement, known to be an important limiting factor in gait for iSCI patients. Fifteen chronic iSCI subjects performed twelve 1-hour sessions of Lokomat training over the course of a month. The voluntary movement was qualified by measuring active range of motion, maximal velocity peak and trajectory smoothness for the spastic ankle during a movement from full plantar-flexion (PF) to full dorsi-flexion (DF) at the patient's maximum speed. Dorsi- and plantar-flexor muscle strength was quantified by isometric maximal voluntary contraction (MVC). Clinical assessments were also performed using the Timed Up and Go (TUG), the 10-meter walk (10MWT) and the 6-minute walk (6MWT) tests. All evaluations were performed both before and after the training and were compared to a control group of fifteen iSCI patients. After the Lokomat training, the active range of motion, the maximal velocity, and the movement smoothness were significantly improved in the voluntary movement. Patients also exhibited an improvement in the MVC for their ankle dorsi- and plantar-flexor muscles. In terms of functional activity, we observed an enhancement in the mobility (TUG) and the over-ground gait velocity (10MWT) with training. Correlation tests indicated a significant relationship between ankle voluntary movement performance and the walking clinical assessments. The improvements of the kinematic and kinetic parameters of the ankle voluntary movement, and their correlation with the functional assessments, support the therapeutic effect of robotic-assisted locomotor training on motor impairment in chronic iSCI.
Motor-response learning at a process control panel by an autonomous robot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spelt, P.F.; de Saussure, G.; Lyness, E.
1988-01-01
The Center for Engineering Systems Advanced Research (CESAR) was founded at Oak Ridge National Laboratory (ORNL) by the Department of Energy's Office of Energy Research/Division of Engineering and Geoscience (DOE-OER/DEG) to conduct basic research in the area of intelligent machines. Therefore, researchers at the CESAR Laboratory are engaged in a variety of research activities in the field of machine learning. In this paper, we describe our approach to a class of machine learning which involves motor response acquisition using feedback from trial-and-error learning. Our formulation is being experimentally validated using an autonomous robot, learning tasks of control panel monitoring andmore » manipulation for effect process control. The CLIPS Expert System and the associated knowledge base used by the robot in the learning process, which reside in a hypercube computer aboard the robot, are described in detail. Benchmark testing of the learning process on a robot/control panel simulation system consisting of two intercommunicating computers is presented, along with results of sample problems used to train and test the expert system. These data illustrate machine learning and the resulting performance improvement in the robot for problems similar to, but not identical with, those on which the robot was trained. Conclusions are drawn concerning the learning problems, and implications for future work on machine learning for autonomous robots are discussed. 16 refs., 4 figs., 1 tab.« less
Robot-Aided Neurorehabilitation: A Robot for Wrist Rehabilitation
Krebs, Hermano Igo; Volpe, Bruce T.; Williams, Dustin; Celestino, James; Charles, Steven K.; Lynch, Daniel; Hogan, Neville
2009-01-01
In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments. PMID:17894265
Robot-aided neurorehabilitation: a robot for wrist rehabilitation.
Krebs, Hermano Igo; Volpe, Bruce T; Williams, Dustin; Celestino, James; Charles, Steven K; Lynch, Daniel; Hogan, Neville
2007-09-01
In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments.
Pilot study of a robotic protocol to treat shoulder subluxation in patients with chronic stroke
2013-01-01
Background Shoulder subluxation is a frequent complication of motor impairment after stroke, leading to soft tissue damage, stretching of the joint capsule, rotator cuff injury, and in some cases pain, thus limiting use of the affected extremity beyond weakness. In this pilot study, we determined whether robotic treatment of chronic shoulder subluxation can lead to functional improvement and whether any improvement was robust. Methods 18 patients with chronic stroke (3.9 ± 2.9 years from acute stroke), completed 6 weeks of robotic training using the linear shoulder robot. Training was performed 3 times per week on alternate days. Each session consisted of 3 sets of 320 repetitions of the affected arm, and the robotic protocol alternated between training vertical arm movements, shoulder flexion and extension, in an anti-gravity plane, and training horizontal arm movements, scapular protraction and retraction, in a gravity eliminated plane. Results Training with the linear robot improved shoulder stability, motor power, and resulted in improved functional outcomes that were robust 3 months after training. Conclusion In this uncontrolled pilot study, the robotic protocol effectively treated shoulder subluxation in chronic stroke patients. Treatment of subluxation can lead to improved functional use of the affected arm, likely by increasing motor power in the trained muscles. PMID:23914834
Pilot study of a robotic protocol to treat shoulder subluxation in patients with chronic stroke.
Dohle, Carolin I; Rykman, Avrielle; Chang, Johanna; Volpe, Bruce T
2013-08-05
Shoulder subluxation is a frequent complication of motor impairment after stroke, leading to soft tissue damage, stretching of the joint capsule, rotator cuff injury, and in some cases pain, thus limiting use of the affected extremity beyond weakness. In this pilot study, we determined whether robotic treatment of chronic shoulder subluxation can lead to functional improvement and whether any improvement was robust. 18 patients with chronic stroke (3.9 ± 2.9 years from acute stroke), completed 6 weeks of robotic training using the linear shoulder robot. Training was performed 3 times per week on alternate days. Each session consisted of 3 sets of 320 repetitions of the affected arm, and the robotic protocol alternated between training vertical arm movements, shoulder flexion and extension, in an anti-gravity plane, and training horizontal arm movements, scapular protraction and retraction, in a gravity eliminated plane. Training with the linear robot improved shoulder stability, motor power, and resulted in improved functional outcomes that were robust 3 months after training. In this uncontrolled pilot study, the robotic protocol effectively treated shoulder subluxation in chronic stroke patients. Treatment of subluxation can lead to improved functional use of the affected arm, likely by increasing motor power in the trained muscles.
Mirheydar, Hossein; Jones, Marklyn; Koeneman, Kenneth S.
2009-01-01
Objective: Currently, robotic training for inexperienced, practicing surgeons is primarily done vis-à-vis industry and/or society-sponsored day or weekend courses, with limited proctorship opportunities. The objective of this study was to assess the impact of an extended-proctorship program at up to 32 months of follow-up. Methods: An extended-proctorship program for robotic-assisted laparoscopic radical prostatectomy was established at our institution. The curriculum consisted of 3 phases: (1) completing an Intuitive Surgical 2-day robotic training course with company representatives; (2) serving as assistant to a trained proctor on 5 to 6 cases; and (3) performing proctored cases up to 1 year until confidence was achieved. Participants were surveyed and asked to evaluate on a 5-point Likert scale their operative experience in robotics and satisfaction regarding their training Results: Nine of 9 participants are currently performing robotic-assisted laparoscopic radical prostatectomy (RALP) independently. Graduates of our program have performed 477 RALP cases. The mean number of cases performed within phase 3 was 20.1 (range, 5 to 40) prior to independent practice. The program received a rating of 4.2/5 for effectiveness in teaching robotic surgery skills. Conclusion: Our robotic program, with extended proctoring, has led to an outstanding take-rate for disseminating robotic skills in a metropolitan community. PMID:19793464
Mirheydar, Hossein; Jones, Marklyn; Koeneman, Kenneth S; Sweet, Robert M
2009-01-01
Currently, robotic training for inexperienced, practicing surgeons is primarily done vis-à-vis industry and/or society-sponsored day or weekend courses, with limited proctorship opportunities. The objective of this study was to assess the impact of an extended-proctorship program at up to 32 months of follow-up. An extended-proctorship program for robotic-assisted laparoscopic radical prostatectomy was established at our institution. The curriculum consisted of 3 phases: (1) completing an Intuitive Surgical 2-day robotic training course with company representatives; (2) serving as assistant to a trained proctor on 5 to 6 cases; and (3) performing proctored cases up to 1 year until confidence was achieved. Participants were surveyed and asked to evaluate on a 5-point Likert scale their operative experience in robotics and satisfaction regarding their training. Nine of 9 participants are currently performing robotic-assisted laparoscopic radical prostatectomy (RALP) independently. Graduates of our program have performed 477 RALP cases. The mean number of cases performed within phase 3 was 20.1 (range, 5 to 40) prior to independent practice. The program received a rating of 4.2/5 for effectiveness in teaching robotic surgery skills. Our robotic program, with extended proctoring, has led to an outstanding take-rate for disseminating robotic skills in a metropolitan community.
A brain-controlled lower-limb exoskeleton for human gait training.
Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua
2017-10-01
Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.
A brain-controlled lower-limb exoskeleton for human gait training
NASA Astrophysics Data System (ADS)
Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua
2017-10-01
Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.
Robotics Programs: Automation Training in Disguise.
ERIC Educational Resources Information Center
Rehg, James A.
1985-01-01
Questions and answers from the book "Guidelines for Robotics Program Development" are presented, addressing some of the major issues confronted by the person setting the direction for a robotics training program. (CT)
Sperry, Steven M; O'Malley, Bert W; Weinstein, Gregory S
2014-01-01
To define a curriculum for the development of robotic surgical skills in otorhinolaryngology residency training. A systematic review of the current literature on robotic surgery training was performed. Based on prior reports in other specialties, a curriculum for otorhinolaryngology residents was created that progresses through several modules, including didactics, inanimate skills laboratory, and operative experience. The curriculum for residents in otorhinolaryngology was designed as follows: didactics include an overview of the robotic device and instruments, a tutorial in basic controls and function, and a room setup and positioning. The anatomy and steps of transoral procedures are taught through books, videos, operative observations, and cadaver dissections. Skills are developed with a virtual reality robotic simulator and robotics labs. The operative experience progresses from case observation to bedside assistant to console surgeon. The role of the console surgeon progresses in a stepwise fashion, and the procedures of radical tonsillectomy, supraglottic partial laryngectomy, and base of tongue resection have been organized as a series of steps. A structured curriculum for training residents in transoral robotic surgery was developed. This training is important for otorhinolaryngology residents to acquire the knowledge and skills to perform robotic surgery safely. © 2015 S. Karger AG, Basel.
2011-10-01
performance metrics; and development of Robotic OR Team training including crisis management. Q3: During the third quarter of this project, the...literature review for robot-assisted surgical skill training/performance metrics; development of Robotic OR Team training materials including crisis ... crisis management situations. Q2: Contract negotiations for the purchase of the da Vinci Skills Simulator are completed and we anticipate the
Morone, Giovanni; Paolucci, Stefano; Cherubini, Andrea; De Angelis, Domenico; Venturiero, Vincenzo; Coiro, Paola; Iosa, Marco
2017-01-01
In this review, we give a brief outline of robot-mediated gait training for stroke patients, as an important emerging field in rehabilitation. Technological innovations are allowing rehabilitation to move toward more integrated processes, with improved efficiency and less long-term impairments. In particular, robot-mediated neurorehabilitation is a rapidly advancing field, which uses robotic systems to define new methods for treating neurological injuries, especially stroke. The use of robots in gait training can enhance rehabilitation, but it needs to be used according to well-defined neuroscientific principles. The field of robot-mediated neurorehabilitation brings challenges to both bioengineering and clinical practice. This article reviews the state of the art (including commercially available systems) and perspectives of robotics in poststroke rehabilitation for walking recovery. A critical revision, including the problems at stake regarding robotic clinical use, is also presented.
Morone, Giovanni; Paolucci, Stefano; Cherubini, Andrea; De Angelis, Domenico; Venturiero, Vincenzo; Coiro, Paola; Iosa, Marco
2017-01-01
In this review, we give a brief outline of robot-mediated gait training for stroke patients, as an important emerging field in rehabilitation. Technological innovations are allowing rehabilitation to move toward more integrated processes, with improved efficiency and less long-term impairments. In particular, robot-mediated neurorehabilitation is a rapidly advancing field, which uses robotic systems to define new methods for treating neurological injuries, especially stroke. The use of robots in gait training can enhance rehabilitation, but it needs to be used according to well-defined neuroscientific principles. The field of robot-mediated neurorehabilitation brings challenges to both bioengineering and clinical practice. This article reviews the state of the art (including commercially available systems) and perspectives of robotics in poststroke rehabilitation for walking recovery. A critical revision, including the problems at stake regarding robotic clinical use, is also presented. PMID:28553117
Foell, Kirsten; Finelli, Antonio; Yasufuku, Kazuhiro; Bernardini, Marcus Q.; Waddell, Thomas K.; Pace, Kenneth T.; Honey, R. John D.’A.; Lee, Jason Y.
2013-01-01
Purpose: Simulation-based training improves clinical skills, while minimizing the impact of the educational process on patient care. We present results of a pilot multidisciplinary, simulation-based robotic surgery basic skills training curriculum (BSTC) for robotic novices. Methods: A 4-week, simulation-based, robotic surgery BSTC was offered to the Departments of Surgery and Obstetrics & Gynecology (ObGyn) at the University of Toronto. The course consisted of various instructional strategies: didactic lecture, self-directed online-training modules, introductory hands-on training with the da Vinci robot (dVR) (Intuitive Surgical Inc., Sunnyvale, CA), and dedicated training on the da Vinci Skills Simulator (Intuitive Surgical Inc., Sunnyvale, CA) (dVSS). A third of trainees participated in competency-based dVSS training, all others engaged in traditional time-based training. Pre- and post-course skill testing was conducted on the dVR using 2 standardized skill tasks: ring transfer (RT) and needle passing (NP). Retention of skills was assessed at 5 months post-BSTC. Results: A total of 37 participants completed training. The mean task completion time and number of errors improved significantly post-course on both RT (180.6 vs. 107.4 sec, p < 0.01 and 3.5 vs. 1.3 sec, p < 0.01, respectively) and NP (197.1 vs. 154.1 sec, p < 0.01 and 4.5 vs. 1.8 sec, p = 0.04, respectively) tasks. No significant difference in performance was seen between specialties. Competency-based training was associated with significantly better post-course performance. The dVSS demonstrated excellent face validity. Conclusions: The implementation of a pilot multidisciplinary, simulation-based robotic surgery BSTC revealed significantly improved basic robotic skills among novice trainees, regardless of specialty or level of training. Competency-based training was associated with significantly better acquisition of basic robotic skills. PMID:24381662
Kim, Geon Ha; Jeon, Seun; Im, Kiho; Kwon, Hunki; Lee, Byung Hwa; Kim, Ga Young; Jeong, Hana; Han, Noh Eul; Seo, Sang Won; Cho, Hanna; Noh, Young; Park, Sang Eon; Kim, Hojeong; Hwang, Jung Won; Yoon, Cindy W.; Kim, Hee Jin; Ye, Byoung Seok; Chin, Ju Hee; Kim, Jung-Hyun; Suh, Mee Kyung; Lee, Jong Min; Kim, Sung Tae; Choi, Mun-Taek; Kim, Mun Sang; Heilman, Kenneth M; Jeong, Jee Hyang; Na, Duk L.
2015-01-01
The purpose of this study was to investigate if multi-domain cognitive training, especially robot-assisted training, alters cortical thickness in the brains of elderly participants. A controlled trial was conducted with 85 volunteers without cognitive impairment who were 60 years old or older. Participants were first randomized into two groups. One group consisted of 48 participants who would receive cognitive training and 37 who would not receive training. The cognitive training group was randomly divided into two groups, 24 who received traditional cognitive training and 24 who received robot-assisted cognitive training. The training for both groups consisted of daily 90-min-session, five days a week for a total of 12 weeks. The primary outcome was the changes in cortical thickness. When compared to the control group, both groups who underwent cognitive training demonstrated attenuation of age related cortical thinning in the frontotemporal association cortices. When the robot and the traditional interventions were directly compared, the robot group showed less cortical thinning in the anterior cingulate cortices. Our results suggest that cognitive training can mitigate age-associated structural brain changes in the elderly. Trial Registration ClnicalTrials.gov NCT01596205 PMID:25898367
Wisneski, Kimberly J; Johnson, Michelle J
2007-03-23
Robotic therapy is at the forefront of stroke rehabilitation. The Activities of Daily Living Exercise Robot (ADLER) was developed to improve carryover of gains after training by combining the benefits of Activities of Daily Living (ADL) training (motivation and functional task practice with real objects), with the benefits of robot mediated therapy (repeatability and reliability). In combining these two therapy techniques, we seek to develop a new model for trajectory generation that will support functional movements to real objects during robot training. We studied natural movements to real objects and report on how initial reaching movements are affected by real objects and how these movements deviate from the straight line paths predicted by the minimum jerk model, typically used to generate trajectories in robot training environments. We highlight key issues that to be considered in modelling natural trajectories. Movement data was collected as eight normal subjects completed ADLs such as drinking and eating. Three conditions were considered: object absent, imagined, and present. This data was compared to predicted trajectories generated from implementing the minimum jerk model. The deviations in both the plane of the table (XY) and the sagittal plane of torso (XZ) were examined for both reaches to a cup and to a spoon. Velocity profiles and curvature were also quantified for all trajectories. We hypothesized that movements performed with functional task constraints and objects would deviate from the minimum jerk trajectory model more than those performed under imaginary or object absent conditions. Trajectory deviations from the predicted minimum jerk model for these reaches were shown to depend on three variables: object presence, object orientation, and plane of movement. When subjects completed the cup reach their movements were more curved than for the spoon reach. The object present condition for the cup reach showed more curvature than in the object imagined and absent conditions. Curvature in the XZ plane of movement was greater than curvature in the XY plane for all movements. The implemented minimum jerk trajectory model was not adequate for generating functional trajectories for these ADLs. The deviations caused by object affordance and functional task constraints must be accounted for in order to allow subjects to perform functional task training in robotic therapy environments. The major differences that we have highlighted include trajectory dependence on: object presence, object orientation, and the plane of movement. With the ability to practice ADLs on the ADLER environment we hope to provide patients with a therapy paradigm that will produce optimal results and recovery.
Current state of virtual reality simulation in robotic surgery training: a review.
Bric, Justin D; Lumbard, Derek C; Frelich, Matthew J; Gould, Jon C
2016-06-01
Worldwide, the annual number of robotic surgical procedures continues to increase. Robotic surgical skills are unique from those used in either open or laparoscopic surgery. The acquisition of a basic robotic surgical skill set may be best accomplished in the simulation laboratory. We sought to review the current literature pertaining to the use of virtual reality (VR) simulation in the acquisition of robotic surgical skills on the da Vinci Surgical System. A PubMed search was conducted between December 2014 and January 2015 utilizing the following keywords: virtual reality, robotic surgery, da Vinci, da Vinci skills simulator, SimSurgery Educational Platform, Mimic dV-Trainer, and Robotic Surgery Simulator. Articles were included if they were published between 2007 and 2015, utilized VR simulation for the da Vinci Surgical System, and utilized a commercially available VR platform. The initial search criteria returned 227 published articles. After all inclusion and exclusion criteria were applied, a total of 47 peer-reviewed manuscripts were included in the final review. There are many benefits to utilizing VR simulation for robotic skills acquisition. Four commercially available simulators have been demonstrated to be capable of assessing robotic skill. Three of the four simulators demonstrate the ability of a VR training curriculum to improve basic robotic skills, with proficiency-based training being the most effective training style. The skills obtained on a VR training curriculum are comparable with those obtained on dry laboratory simulation. The future of VR simulation includes utilization in assessment for re-credentialing purposes, advanced procedural-based training, and as a warm-up tool prior to surgery.
Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Ye, Miao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng
2016-08-01
[Purpose] The aim of this study was to examine the long-term interventions effects of robot-assisted therapy rehabilitation on functional activity levels after anterior cruciate ligament reconstruction. [Subjects and Methods] The subjects were 8 patients (6 males and 2 females) who received anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy lasting for one month. The Timed Up-and-Go test, 10-Meter Walk test, Functional Reach Test, surface electromyography of the vastus lateralis and vastus medialis, and extensor strength of isokinetic movement of the knee joint were evaluated before and after the intervention. [Results] The average value of the of vastus medialis EMG, Functional Reach Test, and the maximum and average extensor strength of the knee joint isokinetic movement increased significantly, and the time of the 10-Meter Walk test decreased significantly. [Conclusion] These results suggest that walking ability and muscle strength can be improved by robotic walking training as a long-term intervention.
Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Ye, Miao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng
2016-01-01
[Purpose] The aim of this study was to examine the long-term interventions effects of robot-assisted therapy rehabilitation on functional activity levels after anterior cruciate ligament reconstruction. [Subjects and Methods] The subjects were 8 patients (6 males and 2 females) who received anterior cruciate ligament reconstruction. The subjects participated in robot-assisted therapy lasting for one month. The Timed Up-and-Go test, 10-Meter Walk test, Functional Reach Test, surface electromyography of the vastus lateralis and vastus medialis, and extensor strength of isokinetic movement of the knee joint were evaluated before and after the intervention. [Results] The average value of the of vastus medialis EMG, Functional Reach Test, and the maximum and average extensor strength of the knee joint isokinetic movement increased significantly, and the time of the 10-Meter Walk test decreased significantly. [Conclusion] These results suggest that walking ability and muscle strength can be improved by robotic walking training as a long-term intervention. PMID:27630396
Robot-assisted gait training in patients with Parkinson disease: a randomized controlled trial.
Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Fiaschi, Antonio; Santilli, Valter; Smania, Nicola
2012-05-01
. Gait impairment is a common cause of disability in Parkinson disease (PD). Electromechanical devices to assist stepping have been suggested as a potential intervention. . To evaluate whether a rehabilitation program of robot-assisted gait training (RAGT) is more effective than conventional physiotherapy to improve walking. . A total of 41 patients with PD were randomly assigned to 45-minute treatment sessions (12 in all), 3 days a week, for 4 consecutive weeks of either robotic stepper training (RST; n = 21) using the Gait Trainer or physiotherapy (PT; n = 20) with active joint mobilization and a modest amount of conventional gait training. Participants were evaluated before, immediately after, and 1 month after treatment. Primary outcomes were 10-m walking speed and distance walked in 6 minutes. . Baseline measures revealed no statistical differences between groups, but the PT group walked 0.12 m/s slower; 5 patients withdrew. A statistically significant improvement was found in favor of the RST group (walking speed 1.22 ± 0.19 m/s [P = .035]; distance 366.06 ± 78.54 m [P < .001]) compared with the PT group (0.98 ± 0.32 m/s; 280.11 ± 106.61 m). The RAGT mean speed increased by 0.13 m/s, which is probably not clinically important. Improvements were maintained 1 month later. . RAGT may improve aspects of walking ability in patients with PD. Future trials should compare robotic assistive training with treadmill or equal amounts of overground walking practice.
Does robotic gait training improve balance in Parkinson's disease? A randomized controlled trial.
Picelli, Alessandro; Melotti, Camilla; Origano, Francesca; Waldner, Andreas; Gimigliano, Raffaele; Smania, Nicola
2012-09-01
Treadmill training (with or without robotic assistance) has been reported to improve balance skills in patients with Parkinson's disease (PD). However, its effectiveness on postural instability has been evaluated mainly in patients with mild to moderate PD (Hoehn & Yahr stage ≤3). Patients with more severe disease may benefit from robot-assisted gait training performed by the Gait-Trainer GT1, as a harness supports them with their feet placed on motor-driven footplates. The aim of this study was to determine whether robot-assisted gait training could have a positive influence on postural stability in patients with PD at Hoehn & Yahr stage 3-4. Thirty-four patients with PD at Hoehn & Yahr stage 3-4 were randomly assigned into two groups. All patients received twelve, 40-min treatment sessions, three days/week, for four consecutive weeks. The Robotic Training group (n = 17) underwent robot-assisted gait training, while the Physical Therapy group (n = 17) underwent a training program not specifically aimed at improving postural stability. Patients were evaluated before, immediately after and 1-month post-treatment. Primary outcomes were: Berg Balance scale; Nutt's rating. A significant improvement was found after treatment on the Berg Balance Scale and the Nutt's rating in favor of the Robotic Training group (Berg: 43.44 ± 2.73; Nutt: 1.38 ± 0.50) compared to the Physical Therapy group (Berg: 37.27 ± 5.68; Nutt: 2.07 ± 0.59). All improvements were maintained at the 1-month follow-up evaluation. Robot-assisted gait training may improve postural instability in patients with PD at Hoehn & Yahr stage 3-4. Copyright © 2012 Elsevier Ltd. All rights reserved.
A robotic voice simulator and the interactive training for hearing-impaired people.
Sawada, Hideyuki; Kitani, Mitsuki; Hayashi, Yasumori
2008-01-01
A talking and singing robot which adaptively learns the vocalization skill by means of an auditory feedback learning algorithm is being developed. The robot consists of motor-controlled vocal organs such as vocal cords, a vocal tract and a nasal cavity to generate a natural voice imitating a human vocalization. In this study, the robot is applied to the training system of speech articulation for the hearing-impaired, because the robot is able to reproduce their vocalization and to teach them how it is to be improved to generate clear speech. The paper briefly introduces the mechanical construction of the robot and how it autonomously acquires the vocalization skill in the auditory feedback learning by listening to human speech. Then the training system is described, together with the evaluation of the speech training by auditory impaired people.
Mazzoleni, S; Battini, E; Rustici, A; Stampacchia, G
2017-07-01
The aim of this study is to investigate the effects of an integrated gait rehabilitation training based on Functional Electrical Stimulation (FES)-cycling and overground robotic exoskeleton in a group of seven complete spinal cord injury patients on spasticity and patient-robot interaction. They underwent a robot-assisted rehabilitation training based on two phases: n=20 sessions of FES-cycling followed by n= 20 sessions of robot-assisted gait training based on an overground robotic exoskeleton. The following clinical outcome measures were used: Modified Ashworth Scale (MAS), Numerical Rating Scale (NRS) on spasticity, Penn Spasm Frequency Scale (PSFS), Spinal Cord Independence Measure Scale (SCIM), NRS on pain and International Spinal Cord Injury Pain Data Set (ISCI). Clinical outcome measures were assessed before (T0) after (T1) the FES-cycling training and after (T2) the powered overground gait training. The ability to walk when using exoskeleton was assessed by means of 10 Meter Walk Test (10MWT), 6 Minute Walk Test (6MWT), Timed Up and Go test (TUG), standing time, walking time and number of steps. Statistically significant changes were found on the MAS score, NRS-spasticity, 6MWT, TUG, standing time and number of steps. The preliminary results of this study show that an integrated gait rehabilitation training based on FES-cycling and overground robotic exoskeleton in complete SCI patients can provide a significant reduction of spasticity and improvements in terms of patient-robot interaction.
Hornby, T George; Kinnaird, Catherine R; Holleran, Carey L; Rafferty, Miriam R; Rodriguez, Kelly S; Cain, Julie B
2012-10-01
Robotic-assisted locomotor training has demonstrated some efficacy in individuals with neurological injury and is slowly gaining clinical acceptance. Both exoskeletal devices, which control individual joint movements, and elliptical devices, which control endpoint trajectories, have been utilized with specific patient populations and are available commercially. No studies have directly compared training efficacy or patient performance during stepping between devices. The purpose of this study was to evaluate kinematic, electromyographic (EMG), and metabolic responses during elliptical- and exoskeletal-assisted stepping in individuals with incomplete spinal cord injury (SCI) compared with therapist-assisted stepping. Design A prospective, cross-sectional, repeated-measures design was used. Participants with incomplete SCI (n=11) performed 3 separate bouts of exoskeletal-, elliptical-, or therapist-assisted stepping. Unilateral hip and knee sagittal-plane kinematics, lower-limb EMG recordings, and oxygen consumption were compared across stepping conditions and with control participants (n=10) during treadmill stepping. Exoskeletal stepping kinematics closely approximated normal gait patterns, whereas significantly greater hip and knee flexion postures were observed during elliptical-assisted stepping. Measures of kinematic variability indicated consistent patterns in control participants and during exoskeletal-assisted stepping, whereas therapist- and elliptical-assisted stepping kinematics were more variable. Despite specific differences, EMG patterns generally were similar across stepping conditions in the participants with SCI. In contrast, oxygen consumption was consistently greater during therapist-assisted stepping. Limitations Limitations included a small sample size, lack of ability to evaluate kinetics during stepping, unilateral EMG recordings, and sagittal-plane kinematics. Despite specific differences in kinematics and EMG activity, metabolic activity was similar during stepping in each robotic device. Understanding potential differences and similarities in stepping performance with robotic assistance may be important in delivery of repeated locomotor training using robotic or therapist assistance and for consumers of robotic devices.
Thomaier, Lauren; Orlando, Megan; Abernethy, Melinda; Paka, Chandhana; Chen, Chi Chiung Grace
2017-08-01
Although surgical simulation provides an effective supplement to traditional training, it is not known whether skills are transferable between minimally invasive surgical modalities. The purpose of this study was to assess the transferability of skills between minimally invasive surgical simulation platforms among simulation-naïve participants. Forty simulation-naïve medical students were enrolled in this randomized single-blinded controlled trial. Participants completed a baseline evaluation on laparoscopic (Fundamentals of Laparoscopic Surgery Program, Los Angeles, CA) and robotic (dV-Trainer, Mimic, Seattle, WA) simulation peg transfer tasks. Participants were then randomized to perform a practice session on either the robotic (N = 20) or laparoscopic (N = 20) simulator. Two blinded, expert minimally invasive surgeons evaluated participants before and after training using a modified previously validated subjective global rating scale. Objective measures including time to task completion and Mimic dV-Trainer motion metrics were also recorded. At baseline, there were no significant differences between the training groups as measured by objective and subjective measures for either simulation task. After training, participants randomized to the laparoscopic practice group completed the laparoscopic task faster (p < 0.003) and with higher global rating scale scores (p < 0.001) than the robotic group. Robotic-trained participants performed the robotic task faster (p < 0.001), with improved economy of motion (p < 0.001), and with higher global rating scale scores (p = 0.006) than the laparoscopic group. The robotic practice group also demonstrated significantly improved performance on the laparoscopic task (p = 0.02). Laparoscopic-trained participants also improved their robotic performance (p = 0.02), though the robotic group had a higher percent improvement on the robotic task (p = 0.037). Skills acquired through practice on either laparoscopic or robotic simulation platforms appear to be transferable between modalities. However, participants demonstrate superior skill in the modality in which they specifically train.
Developing a successful robotics program.
Luthringer, Tyler; Aleksic, Ilija; Caire, Arthur; Albala, David M
2012-01-01
Advancements in the robotic surgical technology have revolutionized the standard of care for many surgical procedures. The purpose of this review is to evaluate the important considerations in developing a new robotics program at a given healthcare institution. Patients' interest in robotic-assisted surgery has and continues to grow because of improved outcomes and decreased periods of hospitalization. Resulting market forces have created a solid foundation for the implementation of robotic surgery into surgical practice. Given proper surgeon experience and an efficient system, robotic-assisted procedures have been cost comparable to open surgical alternatives. Surgeon training and experience is closely linked to the efficiency of a new robotics program. Formally trained robotic surgeons have better patient outcomes and shorter operative times. Training in robotics has shown no negative impact on patient outcomes or mentor learning curves. Individual economic factors of local healthcare settings must be evaluated when planning for a new robotics program. The high cost of the robotic surgical platform is best offset with a large surgical volume. A mature, experienced surgeon is integral to the success of a new robotics program.
Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain
2015-01-01
In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning.
Lam, Tania; Pauhl, Katherine; Krassioukov, Andrei; Eng, Janice J
2011-01-01
The efficacy of task-specific gait training for people with spinal cord injury (SCI) is premised on evidence that the provision of gait-related afferent feedback is key for the recovery of stepping movements. Recent findings have shown that sensory feedback from flexor muscle afferents can facilitate flexor muscle activity during the swing phase of walking. This case report was undertaken to determine the feasibility of using robot-applied forces to resist leg movements during body-weight-supported treadmill training (BWSTT) and to measure its effect on gait and other health-related outcomes. The patient described in this case report was a 43-year-old man with a T11 incomplete chronic SCI. He underwent 36 sessions of BWSTT using a robotic gait orthosis to provide forces that resist hip and knee flexion. Tolerance to the training program was monitored using the Borg CR10 scale and heart rate and blood pressure changes during each training session. Outcome measures (ie, 10-Meter Walk Test, Six-Minute Walk Test, modified Emory Functional Ambulation Profile [mEFAP], Activities-specific Balance Confidence Scale, and Canadian Occupational Performance Measure) were completed and kinematic parameters of gait, lower-extremity muscle strength (force-generating capacity), lower-limb girth, and tolerance to orthostatic stress were measured before and after the training program. The patient could tolerate the training. Overground walking speed, endurance, and performance on all subtasks of the mEFAP improved and were accompanied by increased lower-limb joint flexion and toe clearance during gait. The patient's ambulatory self-confidence and self-perceived performance in walking also improved. These findings suggest that this new approach to BWSTT is a feasible and potentially effective therapy for improving skilled overground walking performance.
Rabadi, Mh; Galgano, M; Lynch, D; Akerman, M; Lesser, M; Volpe, Bt
2008-12-01
To determine the efficacy of activity-based therapies using arm ergometer or robotic or group occupational therapy for motor recovery of the paretic arm in patients with an acute stroke (< or =4 weeks) admitted to an inpatient rehabilitation facility, and to obtain information to plan a large randomized controlled trial. Prospective, randomized controlled study. Stroke unit in a rehabilitation hospital. Thirty patients with an acute stroke (< or =4 weeks) who had arm weakness (Medical Research Council grade 2 or less at the shoulder joint). Occupational therapy (OT) group (control) (n = 10), arm ergometer (n = 10) or robotic (n = 10) therapy group. All patients received standard, inpatient, post-stroke rehabilitation training for 3 hours a day, plus 12 additional 40-minute sessions of the activity-based therapy. The primary outcome measures were discharge scores in the Fugl-Meyer Assessment Scale for upper limb impairment, Motor Status Scale, total Functional Independence Measure (FIM) and FIM-motor and FIM-cognition subscores. The three groups (OT group versus arm ergometer versus robotic) were comparable on clinical demographic measures except the robotic group was significantly older and there were more haemorrhagic stroke patients in the arm ergometer group. After adjusting for age, stroke type and outcome measures at baseline, a similar degree of improvement in the discharge scores was found in all of the primary outcome measures. This study suggests that activity-based therapies using an arm ergometer or robot when used over shortened training periods have the same effect as OT group therapy in decreasing impairment and improving disability in the paretic arm of severely affected stroke patients in the subacute phase.
Tiong, Ho Yee; Goh, Benjamin Yen Seow; Chiong, Edmund; Tan, Lincoln Guan Lim; Vathsala, Anatharaman
2018-03-31
Robotic-assisted kidney transplantation (RKT) with the Da Vinci (Intuitive, USA) platform has been recently developed to improve outcomes by decreasing surgical site complications and morbidity, especially in obese patients. This potential paradigm shift in the surgical technique of kidney transplantation is performed in only a few centers. For wider adoption of this high stake complex operation, we aimed to develop a procedure-specific simulation platform in a porcine model for the training of robotic intracorporeal vascular anastomosis and evaluating vascular anastomoses patency. This paper describes the requirements and steps developed for the above training purpose. Over a series of four animal ethics' approved experiments, the technique of robotic-assisted laparoscopic autotransplantation of the kidney was developed in Amsterdam live pigs (60-70 kg). The surgery was based around the vascular anastomosis technique described by Menon et al. This non-survival porcine training model is targeted at transplant surgeons with robotic surgery experience. Under general anesthesia, each pig was placed in lateral decubitus position with the placement of one robotic camera port, two robotic 8 mm ports and one assistant port. Robotic docking over the pig posteriorly was performed. The training platform involved the following procedural steps. First, ipsilateral iliac vessel dissection was performed. Second, robotic-assisted laparoscopic donor nephrectomy was performed with in situ perfusion of the kidney with cold Hartmann's solution prior to complete division of the hilar vessels, ureter and kidney mobilization. Thirdly, the kidney was either kept in situ for orthotopic autotransplantation or mobilized to the pelvis and orientated for the vascular anastomosis, which was performed end to end or end to side after vessel loop clamping of the iliac vessels, respectively, using 6/0 Gore-Tex sutures. Following autotransplantation and release of vessel loops, perfusion of the graft was assessed using intraoperative indocyanine green imaging and monitoring urine output after unclamping. This training platform demonstrates adequate face and content validity. With practice, arterial anastomotic time could be improved, showing its construct validity. This porcine training model can be useful in providing training for robotic intracorporeal vascular anastomosis and may facilitate confident translation into a transplant human recipient.
Current status of validation for robotic surgery simulators - a systematic review.
Abboudi, Hamid; Khan, Mohammed S; Aboumarzouk, Omar; Guru, Khurshid A; Challacombe, Ben; Dasgupta, Prokar; Ahmed, Kamran
2013-02-01
To analyse studies validating the effectiveness of robotic surgery simulators. The MEDLINE(®), EMBASE(®) and PsycINFO(®) databases were systematically searched until September 2011. References from retrieved articles were reviewed to broaden the search. The simulator name, training tasks, participant level, training duration and evaluation scoring were extracted from each study. We also extracted data on feasibility, validity, cost-effectiveness, reliability and educational impact. We identified 19 studies investigating simulation options in robotic surgery. There are five different robotic surgery simulation platforms available on the market. In all, 11 studies sought opinion and compared performance between two different groups; 'expert' and 'novice'. Experts ranged in experience from 21-2200 robotic cases. The novice groups consisted of participants with no prior experience on a robotic platform and were often medical students or junior doctors. The Mimic dV-Trainer(®), ProMIS(®), SimSurgery Educational Platform(®) (SEP) and Intuitive systems have shown face, content and construct validity. The Robotic Surgical SimulatorTM system has only been face and content validated. All of the simulators except SEP have shown educational impact. Feasibility and cost-effectiveness of simulation systems was not evaluated in any trial. Virtual reality simulators were shown to be effective training tools for junior trainees. Simulation training holds the greatest potential to be used as an adjunct to traditional training methods to equip the next generation of robotic surgeons with the skills required to operate safely. However, current simulation models have only been validated in small studies. There is no evidence to suggest one type of simulator provides more effective training than any other. More research is needed to validate simulated environments further and investigate the effectiveness of animal and cadaveric training in robotic surgery. © 2012 BJU International.
Park, Jae Hyun; Lee, Jandee; Hakim, Nor Azham; Kim, Ha Yan; Kang, Sang-Wook; Jeong, Jong Ju; Nam, Kee-Hyun; Bae, Keum-Seok; Kang, Seong Joon; Chung, Woong Youn
2015-12-01
This study assessed the results of robotic thyroidectomy by fellowship-trained surgeons in their initial independent practice, and whether standard fellowship training for robotic surgery shortens the learning curve. This prospective cohort study evaluated outcomes in 125 patients who underwent robotic thyroidectomy using gasless transaxillary single-incision technique by 2 recently graduated fellowship-trained surgeons. Learning curves were analyzed by operation time, with proficiency defined as the point at which the slope of the time curve became less steep. Of the 125 patients, 113 underwent robotic less-than-total thyroidectomy, 9 underwent robotic total thyroidectomy and 3 underwent robotic total thyroidectomy with modified radical neck dissection. Mean total times for these 3 operations were 100.8 ± 20.6 minutes, 134.2 ± 38.7 minutes, and 284.7 ± 60.4 minutes, respectively. For both surgeons, the operation times gradually decreased, reaching a plateau after 20 robotic less-than-total thyroidectomies. The surgical learning curve for robotic thyroidectomy performed by recently graduated fellowship-trained surgeons with little or no experience in endoscopic surgery showed excellent results compared with those in a large series of more experienced surgeons. © 2014 Wiley Periodicals, Inc.
Daunoraviciene, Kristina; Adomaviciene, Ausra; Grigonyte, Agne; Griškevičius, Julius; Juocevicius, Alvydas
2018-05-18
The study aims to determine the effectiveness of robot-assisted training in the recovery of stroke-affected arms using an exoskeleton robot Armeo Spring. To identify the effect of robot training on functional recovery of the arm. A total of 34 stroke patients were divided into either an experimental group (EG; n= 17) or a control group (n= 17). EG was also trained to use the Armeo Spring during occupational therapy. Both groups were clinically assessed before and after treatment. Statistical comparison methods (i.e. one-tailed t-tests for differences between two independent means and the simplest test) were conducted to compare motor recovery using robot-assisted training or conventional therapy. Patients assigned to the EG showed a statistically significant improvement in upper extremity motor function when compared to the CG by FIM (P< 0.05) and ACER (P< 0.05). The calculated treatment effect in the EG and CG was meaningful for shoulder and elbow kinematic parameters. The findings show the benefits of robot therapy in two areas of functional recovery. Task-oriented robotic training in rehabilitation setting facilitates recovery not only of the motor function of the paretic arm but also of the cognitive abilities in stroke patients.
Design and Development Issues for Educational Robotics Training Camps
ERIC Educational Resources Information Center
Ucgul, Memet; Cagiltay, Kursat
2014-01-01
The aim of this study is to explore critical design issues for educational robotics training camps and to describe how these factors should be implemented in the development of such camps. For this purpose, two robotics training camps were organized for elementary school students. The first camp had 30 children attendees, and the second had 22. As…
2015-06-01
Award Number: W81XWH-10-1-0981 TITLE: "A Comparison of Robotic , Body Weight-Supported Locomotor Training and Aquatic Therapy in Chronic Motor...ABSTRACT U c. THIS PAGE U 19b. TELEPHONE NUMBER (include area code) email: pgorman@umm.edu "A Comparison of Robotic , Body Weight-Supported...months, three times a week aquatic therapy with similar intensity robotically assisted, body weight supported locomotor training (RABWSLT) upon
Robotic neurorehabilitation: a computational motor learning perspective
Huang, Vincent S; Krakauer, John W
2009-01-01
Conventional neurorehabilitation appears to have little impact on impairment over and above that of spontaneous biological recovery. Robotic neurorehabilitation has the potential for a greater impact on impairment due to easy deployment, its applicability across of a wide range of motor impairment, its high measurement reliability, and the capacity to deliver high dosage and high intensity training protocols. We first describe current knowledge of the natural history of arm recovery after stroke and of outcome prediction in individual patients. Rehabilitation strategies and outcome measures for impairment versus function are compared. The topics of dosage, intensity, and time of rehabilitation are then discussed. Robots are particularly suitable for both rigorous testing and application of motor learning principles to neurorehabilitation. Computational motor control and learning principles derived from studies in healthy subjects are introduced in the context of robotic neurorehabilitation. Particular attention is paid to the idea of context, task generalization and training schedule. The assumptions that underlie the choice of both movement trajectory programmed into the robot and the degree of active participation required by subjects are examined. We consider rehabilitation as a general learning problem, and examine it from the perspective of theoretical learning frameworks such as supervised and unsupervised learning. We discuss the limitations of current robotic neurorehabilitation paradigms and suggest new research directions from the perspective of computational motor learning. PMID:19243614
Duarte, Jaime E; Gebrekristos, Berkenesh; Perez, Sergi; Rowe, Justin B; Sharp, Kelli; Reinkensmeyer, David J
2013-06-01
Robotic devices can modulate success rates and required effort levels during motor training, but it is unclear how this affects performance gains and motivation. Here we present results from training unimpaired humans in a virtual golf-putting task, and training spinal cord injured (SCI) rats in a grip strength task using robotically modulated success rates and effort levels. Robotic assistance in golf practice increased trainees feelings of competence, and, paradoxically, increased their sense effort, even though it had mixed effects on learning. Reducing effort during a grip strength training task led rats with SCI to practice the task more frequently. However, the more frequent practice of these rats did not cause them to exceed the strength gains achieved by rats that exercised less often at higher required effort levels. These results show that increasing success and decreasing effort with robots increases motivation, but has mixed effects on performance gains.
Bouchard, Amy E; Corriveau, Hélène; Milot, Marie-Hélène
2015-01-01
With age, a decline in the temporal aspect of movement is observed such as a longer movement execution time and a decreased timing accuracy. Robotic training can represent an interesting approach to help improve movement timing among the elderly. Two types of robotic training-haptic guidance (HG; demonstrating the correct movement for a better movement planning and improved execution of movement) and error amplification (EA; exaggerating movement errors to have a more rapid and complete learning) have been positively used in young healthy subjects to boost timing accuracy. For healthy seniors, only HG training has been used so far where significant and positive timing gains have been obtained. The goal of the study was to evaluate and compare the impact of both HG and EA robotic trainings on the improvement of seniors' movement timing. Thirty-two healthy seniors (mean age 68 ± 4 years) learned to play a pinball-like game by triggering a one-degree-of-freedom hand robot at the proper time to make a flipper move and direct a falling ball toward a randomly positioned target. During HG and EA robotic trainings, the subjects' timing errors were decreased and increased, respectively, based on the subjects' timing errors in initiating a movement. Results showed that only HG training benefited learning, but the improvement did not generalize to untrained targets. Also, age had no influence on the efficacy of HG robotic training, meaning that the oldest subjects did not benefit more from HG training than the younger senior subjects. Using HG to teach the correct timing of movement seems to be a good strategy to improve motor learning for the elderly as for younger people. However, more studies are needed to assess the long-term impact of HG robotic training on improvement in movement timing.
Robot-Assisted Training for People With Spinal Cord Injury: A Meta-Analysis.
Cheung, Eddy Y Y; Ng, Thomas K W; Yu, Kevin K K; Kwan, Rachel L C; Cheing, Gladys L Y
2017-11-01
To investigate the effects of robot-assisted training on the recovery of people with spinal cord injury (SCI). Randomized controlled trials (RCTs) or quasi-RCTs involving people with SCI that compared robot-assisted upper limbs or lower limbs training with a control of other treatment approach or no treatment. We included studies involving people with complete or incomplete SCIs. We searched MEDLINE, CINAHL, Cochrane Central Register of Controlled Trials (Cochrane Library), and Embase to August 2016. Bibliographies of relevant articles on the effect of body-weight-supported treadmill training on subjects with SCI were screened to avoid missing relevant articles from the search of databases. All kinds of objective assessments concerning physical ability, mobility, and/or functional ability were included. Assessments could be clinical tests (ie, 6-minute walk test, FIM) or laboratory tests (ie, gait analysis). Subjective outcome measures were excluded from this review. Eleven RCT studies involving 443 subjects were included in the study. Meta-analysis was performed on the included studies. Walking independence (3.73; 95% confidence interval [CI], -4.92 to -2.53; P<.00001; I 2 =38%) and endurance (53.32m; 95% CI, -73.15 to -33.48; P<.00001; I 2 =0%) were found to have better improvement in robot-assisted training groups. Lower limb robot-assisted training was also found to be as effective as other types of body-weight-supported training. There is a lack of upper limb robot-assisted training studies; therefore, performing a meta-analysis was not possible. Robot-assisted training is an adjunct therapy for physical and functional recovery for patients with SCI. Future high-quality studies are warranted to investigate the effects of robot-assisted training on functional and cardiopulmonary recovery of patients with SCI. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Medical Engineering and Microneurosurgery: Application and Future.
Morita, Akio; Sora, Shigeo; Nakatomi, Hirofumi; Harada, Kanako; Sugita, Naohiko; Saito, Nobuhito; Mitsuishi, Mamoru
2016-10-15
Robotics and medical engineering can convert traditional surgery into digital and scientific procedures. Here, we describe our work to develop microsurgical robotic systems and apply engineering technology to assess microsurgical skills. With the collaboration of neurosurgeons and an engineering team, we have developed two types of microsurgical robotic systems. The first, the deep surgical systems, enable delicate surgical procedures such as vessel suturing in a deep and narrow space. The second type allows for super-fine surgical procedures such as anastomosing artificial vessels of 0.3 mm in diameter. Both systems are constructed with master and slave manipulator robots connected to local area networks. Robotic systems allowed for secure and accurate procedures in a deep surgical field. In cadaveric models, these systems showed a good potential of being useful in actual human surgeries, but mechanical refinements in thickness and durability are necessary for them to be established as clinical systems. The super-fine robotic system made the very intricate surgery possible and will be applied in clinical trials. Another trial included the digitization of surgical technique and scientific analysis of surgical skills. Robotic and human hand motions were analyzed in numerical fashion as we tried to define surgical skillfulness in a digital format. Engineered skill assessment is also feasible and should be useful for microsurgical training. Robotics and medical engineering should bring science into the surgical field and training of surgeons. Active collaboration between medical and engineering teams and academic and industry groups is mandatory to establish such medical systems to improve patient care.
Medical Engineering and Microneurosurgery: Application and Future
MORITA, Akio; SORA, Shigeo; NAKATOMI, Hirofumi; HARADA, Kanako; SUGITA, Naohiko; SAITO, Nobuhito; MITSUISHI, Mamoru
2016-01-01
Robotics and medical engineering can convert traditional surgery into digital and scientific procedures. Here, we describe our work to develop microsurgical robotic systems and apply engineering technology to assess microsurgical skills. With the collaboration of neurosurgeons and an engineering team, we have developed two types of microsurgical robotic systems. The first, the deep surgical systems, enable delicate surgical procedures such as vessel suturing in a deep and narrow space. The second type allows for super-fine surgical procedures such as anastomosing artificial vessels of 0.3 mm in diameter. Both systems are constructed with master and slave manipulator robots connected to local area networks. Robotic systems allowed for secure and accurate procedures in a deep surgical field. In cadaveric models, these systems showed a good potential of being useful in actual human surgeries, but mechanical refinements in thickness and durability are necessary for them to be established as clinical systems. The super-fine robotic system made the very intricate surgery possible and will be applied in clinical trials. Another trial included the digitization of surgical technique and scientific analysis of surgical skills. Robotic and human hand motions were analyzed in numerical fashion as we tried to define surgical skillfulness in a digital format. Engineered skill assessment is also feasible and should be useful for microsurgical training. Robotics and medical engineering should bring science into the surgical field and training of surgeons. Active collaboration between medical and engineering teams and academic and industry groups is mandatory to establish such medical systems to improve patient care. PMID:27464471
Controlling patient participation during robot-assisted gait training
2011-01-01
Background The overall goal of this paper was to investigate approaches to controlling active participation in stroke patients during robot-assisted gait therapy. Although active physical participation during gait rehabilitation after stroke was shown to improve therapy outcome, some patients can behave passively during rehabilitation, not maximally benefiting from the gait training. Up to now, there has not been an effective method for forcing patient activity to the desired level that would most benefit stroke patients with a broad variety of cognitive and biomechanical impairments. Methods Patient activity was quantified in two ways: by heart rate (HR), a physiological parameter that reflected physical effort during body weight supported treadmill training, and by a weighted sum of the interaction torques (WIT) between robot and patient, recorded from hip and knee joints of both legs. We recorded data in three experiments, each with five stroke patients, and controlled HR and WIT to a desired temporal profile. Depending on the patient's cognitive capabilities, two different approaches were taken: either by allowing voluntary patient effort via visual instructions or by forcing the patient to vary physical effort by adapting the treadmill speed. Results We successfully controlled patient activity quantified by WIT and by HR to a desired level. The setup was thereby individually adaptable to the specific cognitive and biomechanical needs of each patient. Conclusion Based on the three successful approaches to controlling patient participation, we propose a metric which enables clinicians to select the best strategy for each patient, according to the patient's physical and cognitive capabilities. Our framework will enable therapists to challenge the patient to more activity by automatically controlling the patient effort to a desired level. We expect that the increase in activity will lead to improved rehabilitation outcome. PMID:21429200
Controlling patient participation during robot-assisted gait training.
Koenig, Alexander; Omlin, Ximena; Bergmann, Jeannine; Zimmerli, Lukas; Bolliger, Marc; Müller, Friedemann; Riener, Robert
2011-03-23
The overall goal of this paper was to investigate approaches to controlling active participation in stroke patients during robot-assisted gait therapy. Although active physical participation during gait rehabilitation after stroke was shown to improve therapy outcome, some patients can behave passively during rehabilitation, not maximally benefiting from the gait training. Up to now, there has not been an effective method for forcing patient activity to the desired level that would most benefit stroke patients with a broad variety of cognitive and biomechanical impairments. Patient activity was quantified in two ways: by heart rate (HR), a physiological parameter that reflected physical effort during body weight supported treadmill training, and by a weighted sum of the interaction torques (WIT) between robot and patient, recorded from hip and knee joints of both legs. We recorded data in three experiments, each with five stroke patients, and controlled HR and WIT to a desired temporal profile. Depending on the patient's cognitive capabilities, two different approaches were taken: either by allowing voluntary patient effort via visual instructions or by forcing the patient to vary physical effort by adapting the treadmill speed. We successfully controlled patient activity quantified by WIT and by HR to a desired level. The setup was thereby individually adaptable to the specific cognitive and biomechanical needs of each patient. Based on the three successful approaches to controlling patient participation, we propose a metric which enables clinicians to select the best strategy for each patient, according to the patient's physical and cognitive capabilities. Our framework will enable therapists to challenge the patient to more activity by automatically controlling the patient effort to a desired level. We expect that the increase in activity will lead to improved rehabilitation outcome.
Method for neural network control of motion using real-time environmental feedback
NASA Technical Reports Server (NTRS)
Buckley, Theresa M. (Inventor)
1997-01-01
A method of motion control for robotics and other automatically controlled machinery using a neural network controller with real-time environmental feedback. The method is illustrated with a two-finger robotic hand having proximity sensors and force sensors that provide environmental feedback signals. The neural network controller is taught to control the robotic hand through training sets using back- propagation methods. The training sets are created by recording the control signals and the feedback signal as the robotic hand or a simulation of the robotic hand is moved through a representative grasping motion. The data recorded is divided into discrete increments of time and the feedback data is shifted out of phase with the control signal data so that the feedback signal data lag one time increment behind the control signal data. The modified data is presented to the neural network controller as a training set. The time lag introduced into the data allows the neural network controller to account for the temporal component of the robotic motion. Thus trained, the neural network controlled robotic hand is able to grasp a wide variety of different objects by generalizing from the training sets.
[Study on the center-driven multiple degrees of freedom upper limb rehabilitation training robot].
Huang, Xiaohai; Yu, Hongliu; Wang, Jinchao; Dong, Qi; Zhang, Linling; Meng, Qiaoling; Li, Sujiao; Wang, Duojin
2018-03-01
With the aging of the society, the number of stroke patients has been increasing year by year. Compared with the traditional rehabilitation therapy, the application of upper limb rehabilitation robot has higher efficiency and better rehabilitation effect, and has become an important development direction in the field of rehabilitation. In view of the current development status and the deficiency of upper limb rehabilitation robot system, combined with the development trend of all kinds of products of the upper limb rehabilitation robot, this paper designed a center-driven upper limb rehabilitation training robot for cable transmission which can help the patients complete 6 degrees of freedom (3 are driven, 3 are underactuated) training. Combined the structure of robot with more joints rehabilitation training, the paper choosed a cubic polynomial trajectory planning method in the joint space planning to design two trajectories of eating and lifting arm. According to the trajectory equation, the movement trajectory of each joint of the robot was drawn in MATLAB. It laid a foundation for scientific and effective rehabilitation training. Finally, the experimental prototype is built, and the mechanical structure and design trajectories are verified.
Madoński, R; Kordasz, M; Sauer, P
2014-07-01
The paper presents an application of a special case of an Active Disturbance Rejection Controller (ADRC) in governing a proper realization of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behavior resembles a real robotic rehabilitation device. The multidimensional character of the considered assisting mechanism makes it a nontrivial modeling and control problem. However, by the use of the ADRC approach, the modeling uncertainty in the plant is partially decoupled from the system, which increases the robustness of the whole control framework against both internal and external disturbances. © 2013 ISA. Published by ISA. All rights reserved.
Rupp, Rüdiger; Plewa, Harry; Schuld, Christian; Gerner, Hans Jürgen; Hofer, Eberhard P; Knestel, Markus
2011-02-01
In incomplete spinal cord injured subjects, task-oriented training regimes are applied for enhancement of neuroplasticity to improve gait capacity. However, a sufficient training intensity can only be achieved during the inpatient phase, which is getting shorter and shorter due to economic restrictions. In the clinical environment, complex and expensive robotic devices have been introduced to maintain the duration and the intensity of the training, but up to now only a few exist for continuation of automated locomotion training at home. For continuation of the automated locomotion training at home prototypes of the compact, pneumatically driven orthosis MoreGait have been realized, which generate the key afferent stimuli for activation of the spinal gait pattern generator. Artificial pneumatic muscles with excellent weight-to-force ratio and safety characteristics have been integrated as joint actuators. Additionally, a Stimulative Shoe for generation of the appropriate foot loading pattern has been developed without the need for verticalization of the user. The first results of the pilot study in eight chronic incomplete spinal cord injured subjects indicate that the home-based therapy is safe and feasible. The therapy related improvements of the walking capacity are in the range of locomotion robots used in clinical settings.
Paker, Nurdan; Bugdayci, Derya; Goksenoglu, Goksen; Sen, Aysu; Kesiktas, Nur
2013-01-01
Decreased mobility and walking capacity occur frequently in Parkinson's disease (PD). Robotic treadmill training is a novel method to improve the walking capacity in rehabilitation. The primary aim of this study was to investigate the effects of robotic treadmill training on functional mobility and walking capacity in PD. Secondly, we aimed to assess the effects of the robotic treadmill training the motor symptoms and quality of life in patients with PD. Seventy patients with idiopathic Parkinson's disease who admitted to the outpatient clinic of the rehabilitation hospital were screened and 12 ambulatory volenteers who met the study criteria were included in this study. Patients were evaluated by Hoehn Yahr (HY) scale clinically. Two sessions robotic treadmill training per week during 5 weeks was planned for every patient. Patients were evaluated by the Timed Up and Go (TUG) test, 10 meter walking test (10 MWT), Unified Parkinson's Disease Rating Scale (UPDRS) motor section and Parkinson's Disease Questionnaire-39 (PDQ-39) at the baseline, at the 5 and 12 weeks. Cognitive and emotional states of the patients were assessed by Mini Mental State Examination (MMSE) test and Hospital Anxiety and Depression Scale (HADS) at the baseline. All patients were under medical treatment for the PD in this study and drug treatment was not changed during the study. Ten patients completed the study. The mean age was 65.6 ± 6.6 years. Five patients (50%) were women. Disease severity was between the HY stage 1-3. Two patients did not continue the robotic treadmill training after 7 sessions. They also did not want to come for control visits. TUG test, 10 MWT and UPDRS motor subscale scores showed statistically significant improvement after robotic treadmill training (p = 0.02, p = 0.001, p = 0.016). PDQ-39 scores improved significantly after robotic treadmill training (p = 0.03), however, the scores turned back to the baseline level at the 12. week control. As a result of this preliminary study, robotic treadmill training was useful to improve the functional mobility, walking capacity and motor symptoms in mild to moderate PD. Robotic treadmill training provided a transient improvement in the quality of life during the treatment.
Rehabilitation robotics: pilot trial of a spatial extension for MIT-Manus
Krebs, Hermano I; Ferraro, Mark; Buerger, Stephen P; Newbery, Miranda J; Makiyama, Antonio; Sandmann, Michael; Lynch, Daniel; Volpe, Bruce T; Hogan, Neville
2004-01-01
Background Previous results with the planar robot MIT-MANUS demonstrated positive benefits in trials with over 250 stroke patients. Consistent with motor learning, the positive effects did not generalize to other muscle groups or limb segments. Therefore we are designing a new class of robots to exercise other muscle groups or limb segments. This paper presents basic engineering aspects of a novel robotic module that extends our approach to anti-gravity movements out of the horizontal plane and a pilot study with 10 outpatients. Patients were trained during the initial six-weeks with the planar module (i.e., performance-based training limited to horizontal movements with gravity compensation). This training was followed by six-weeks of robotic therapy that focused on performing vertical arm movements against gravity. The 12-week protocol includes three one-hour robot therapy sessions per week (total 36 robot treatment sessions). Results Pilot study demonstrated that the protocol was safe and well tolerated with no patient presenting any adverse effect. Consistent with our past experience with persons with chronic strokes, there was a statistically significant reduction in tone measurement from admission to discharge of performance-based planar robot therapy and we have not observed increases in muscle tone or spasticity during the anti-gravity training protocol. Pilot results showed also a reduction in shoulder-elbow impairment following planar horizontal training. Furthermore, it suggested an additional reduction in shoulder-elbow impairment following the anti-gravity training. Conclusion Our clinical experiments have focused on a fundamental question of whether task specific robotic training influences brain recovery. To date several studies demonstrate that in mature and damaged nervous systems, nurture indeed has an effect on nature. The improved recovery is most pronounced in the trained limb segments. We have now embarked on experiments that test whether we can continue to influence recovery, long after the acute insult, with a novel class of spatial robotic devices. This pilot results support the pursuit of further clinical trials to test efficacy and the pursuit of optimal therapy following brain injury. PMID:15679916
Rehabilitation robotics: pilot trial of a spatial extension for MIT-Manus.
Krebs, Hermano I; Ferraro, Mark; Buerger, Stephen P; Newbery, Miranda J; Makiyama, Antonio; Sandmann, Michael; Lynch, Daniel; Volpe, Bruce T; Hogan, Neville
2004-10-26
BACKGROUND: Previous results with the planar robot MIT-MANUS demonstrated positive benefits in trials with over 250 stroke patients. Consistent with motor learning, the positive effects did not generalize to other muscle groups or limb segments. Therefore we are designing a new class of robots to exercise other muscle groups or limb segments. This paper presents basic engineering aspects of a novel robotic module that extends our approach to anti-gravity movements out of the horizontal plane and a pilot study with 10 outpatients. Patients were trained during the initial six-weeks with the planar module (i.e., performance-based training limited to horizontal movements with gravity compensation). This training was followed by six-weeks of robotic therapy that focused on performing vertical arm movements against gravity. The 12-week protocol includes three one-hour robot therapy sessions per week (total 36 robot treatment sessions). RESULTS: Pilot study demonstrated that the protocol was safe and well tolerated with no patient presenting any adverse effect. Consistent with our past experience with persons with chronic strokes, there was a statistically significant reduction in tone measurement from admission to discharge of performance-based planar robot therapy and we have not observed increases in muscle tone or spasticity during the anti-gravity training protocol. Pilot results showed also a reduction in shoulder-elbow impairment following planar horizontal training. Furthermore, it suggested an additional reduction in shoulder-elbow impairment following the anti-gravity training. CONCLUSION: Our clinical experiments have focused on a fundamental question of whether task specific robotic training influences brain recovery. To date several studies demonstrate that in mature and damaged nervous systems, nurture indeed has an effect on nature. The improved recovery is most pronounced in the trained limb segments. We have now embarked on experiments that test whether we can continue to influence recovery, long after the acute insult, with a novel class of spatial robotic devices. This pilot results support the pursuit of further clinical trials to test efficacy and the pursuit of optimal therapy following brain injury.
Huang, Xianwei; Naghdy, Fazel; Naghdy, Golshah; Du, Haiping
2017-07-01
Robot-assisted therapy is regarded as an effective and reliable method for the delivery of highly repetitive rehabilitation training in restoring motor skills after a stroke. This study focuses on the rehabilitation of fine hand motion skills due to their vital role in performing delicate activities of daily living (ADL) tasks. The proposed rehabilitation system combines an adaptive assist-as-needed (AAN) control algorithm and a Virtual Reality (VR) based rehabilitation gaming system (RGS). The developed system is described and its effectiveness is validated through clinical trials on a group of eight subacute stroke patients for a period of six weeks. The impact of the training is verified through standard clinical evaluation methods and measuring key kinematic parameters. A comparison of the pre- and post-training results indicates that the method proposed in this study can improve fine hand motion rehabilitation training effectiveness.
Lokomat training in vascular dementia: motor improvement and beyond!
Calabrò, Rocco Salvatore; De Luca, Rosaria; Leo, Antonino; Balletta, Tina; Marra, Angela; Bramanti, Placido
2015-12-01
Vascular dementia (VaD) is a general term describing problems with reasoning, planning, judgment, memory, and other thought processes caused by brain damage from impaired blood flow to the brain. Cognitive rehabilitation and physical therapy are the mainstays of dementia treatment, although often ineffective because of the scarce collaboration of the patients. However, emerging data suggest that physical activity may reduce the risk of cognitive impairment, mainly VaD, in older people living independently. Herein, we describe a 72-year-old male affected by VaD, in which traditional cognitive training in addition to intensive gait robotic rehabilitation (by using Lokomat device) led to a significant improvement in the motor and cognitive function. This promising finding may be related either to the intensive and repetitive aerobic exercises or to the task-oriented training with computerized visual feedback, which can be considered as a relevant tool to increase patients' motor output, involvement, and motivation during robotic training.
The decisive role of the patient-side surgeon in robotic surgery.
Sgarbura, Olivia; Vasilescu, Catalin
2010-12-01
Minimally invasive technology literature is mainly concerned about the feasibility of the robotic procedures and the performance of the console surgeon. However, few of these technologies could be applied without a well-trained team. Our goal was to demonstrate that robotic surgery depends more on the patient-side assistant surgeon's abilities than has been previously reported. In our department, 280 interventions in digestive, thoracic, and gynecological surgery were performed since the acquisition of the robotic equipment. There are three teams trained in robotic surgery with three console surgeons and four certified patient-side surgeons. Four more patient-side assistants were trained at our center. Trocar placement, docking and undocking of the robot, insertion of the laparoscopic instruments, and hemostatic maneuvers with various devices were quantified and compared. Assistants trained by using animal or cadaver surgery are more comfortable with the robotic instruments handling and with docking and undocking of the robot. Assistants who finalized their residency or attend their final year are more accurate with the insertion of the laparoscopic instrument to the targeted organ and more skillful with LigaSure or clip applier devices. Interventions that require vivid participation of the assistants have shorter assistant-depending time intervals at the end of the learning curve than at the beginning. Robotic surgery is a team effort and is greatly dependant on the performance of assistant surgeons. Interventions that have the benefit of a trained team are more rapid and secure.
Mentoring console improves collaboration and teaching in surgical robotics.
Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R
2006-10-01
One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P < 0.01) and by 34% compared to single-resident operation (P < 0.001). While swap mode was found to be most helpful during parts of surgical procedures that require multiple hands (such as isolation and division of vessels), nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.
Robotic surgery of the liver: Italian experience and review of the literature
Reggiani, P; Antonelli, B; Rossi, G
2013-01-01
Robotic liver resection is a new promising minimally invasive surgical technique not yet validated by level I evidence. During recent years, the application of the laparoscopic approach to liver resection has grown less than other abdominal specialties due to the intrinsic limitations of laparoscopic instruments. Robotics can overcome these limitations above all for complex operations. A review of the literature on major hepatic surgery was conducted on PubMed using selected keywords. Two hundred and thirty-five patients in 17 series were analysed and outcomes such as operative time, estimated blood loss, length of hospital stay, complications, conversion rate, and costs were described. The most commonly performed procedures were wedge resection and segmentectomy, but the predominance of major hepatectomies performed with robotic surgery is likely due to the superior control achieved by the robotic system. The conversion and complication rates were 4.2% and 13.4%, respectively. Intracavitary fluid collections and bile leaks were the most frequently occurring morbidities. The mean operation time was 285 min. The mean intraoperative blood loss was 50–280 mL. The mean postoperative hospital stay was four to seven days. Overall survival and long-term outcomes were not reported. Robotic liver surgery in Italy has become a clinical reality that is gaining increasing acceptance; a survey was carried out on robotic surgery, which showed that it is perceived as a significant advantage for operators and a consistent gain for the patient. More than 100 robotic hepatic resections have been performed in Italy where important robotic training schools are active. Robotic liver surgery is feasible and safe in trained and experienced hands. Further evaluation is required to assess the improvement in outcomes and long-term oncologic follow-up. PMID:24174991
Lower-Limb Rehabilitation Robot Design
NASA Astrophysics Data System (ADS)
Bouhabba, E. M.; Shafie, A. A.; Khan, M. R.; Ariffin, K.
2013-12-01
It is a general assumption that robotics will play an important role in therapy activities within rehabilitation treatment. In the last decade, the interest in the field has grown exponentially mainly due to the initial success of the early systems and the growing demand caused by increasing numbers of stroke patients and their associate rehabilitation costs. As a result, robot therapy systems have been developed worldwide for training of both the upper and lower extremities. This paper investigates and proposes a lower-limb rehabilitation robot that is used to help patients with lower-limb paralysis to improve and resume physical functions. The proposed rehabilitation robot features three rotary joints forced by electric motors providing linear motions. The paper covers mechanism design and optimization, kinematics analysis, trajectory planning, wearable sensors, and the control system design. The design and control system demonstrate that the proposed rehabilitation robot is safe and reliable with the effective design and better kinematic performance.
Nurses' Needs for Care Robots in Integrated Nursing Care Services.
Lee, Jai-Yon; Song, Young Ae; Jung, Ji Young; Kim, Hyun Jeong; Kim, Bo Ram; Do, Hyun-Kyung; Lim, Jae-Young
2018-05-13
To determine the need for care robots among nurses and to suggest how robotic care should be prioritized in an integrated nursing care services. Korea is expected to be a super-aged society by 2030. To solve care issues with elderly inpatient caused by informal caregivers, the government introduced 'integrated nursing care services'; these are comprehensive care systems staffed by professionally trained nurses. To assist them, a care robot development project has been launched. The study applied a cross-sectional survey. In 2016, we conducted a multi-center survey involving 302 registered nurses in five hospitals including three tertiary and two secondary hospitals in Korea. The questionnaire consisted of general characteristics of nurses and their views on and extents of agreement about issues associated with robotic care. Trial center nurses and those with ≥10 years of experience reported positively on the prospects for robotic care. The top three desired primary roles for care robots were 'measuring/monitoring', 'mobility/activity' and 'safety care'. 'Reduction in workload', especially in terms of 'other nursing services' which were categorized as non-value-added nursing activities, was the most valued feature. The nurses approved of the aid by care robots but were concerned about device malfunction and interruption of rapport with patients. Care robots are expected to be effective in integrated nursing care services, particularly in 'measuring/monitoring'. Such robots should decrease nurses' workload and minimize non-value-added nursing activities efficiently. No matter how excellent care robots are, they must co-operate with and be controlled by nurses. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Bilateral robots for upper-limb stroke rehabilitation: State of the art and future prospects.
Sheng, Bo; Zhang, Yanxin; Meng, Wei; Deng, Chao; Xie, Shengquan
2016-07-01
Robot-assisted bilateral upper-limb training grows abundantly for stroke rehabilitation in recent years and an increasing number of devices and robots have been developed. This paper aims to provide a systematic overview and evaluation of existing bilateral upper-limb rehabilitation devices and robots based on their mechanisms and clinical-outcomes. Most of the articles studied here were searched from nine online databases and the China National Knowledge Infrastructure (CNKI) from year 1993 to 2015. Devices and robots were categorized as end-effectors, exoskeletons and industrial robots. Totally ten end-effectors, one exoskeleton and one industrial robot were evaluated in terms of their mechanical characteristics, degrees of freedom (DOF), supported control modes, clinical applicability and outcomes. Preliminary clinical results of these studies showed that all participants could gain certain improvements in terms of range of motion, strength or physical function after training. Only four studies supported that bilateral training was better than unilateral training. However, most of clinical results cannot definitely verify the effectiveness of mechanisms and clinical protocols used in robotic therapies. To explore the actual value of these robots and devices, further research on ingenious mechanisms, dose-matched clinical protocols and universal evaluation criteria should be conducted in the future. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Grosmaire, Anne Gaëlle; Battini, Elena
2017-01-01
A better understanding of the neural substrates that underlie motor recovery after stroke has led to the development of innovative rehabilitation strategies and tools that incorporate key elements of motor skill relearning, that is, intensive motor training involving goal-oriented repeated movements. Robotic devices for the upper limb are increasingly used in rehabilitation. Studies have demonstrated the effectiveness of these devices in reducing motor impairments, but less so for the improvement of upper limb function. Other studies have begun to investigate the benefits of combined approaches that target muscle function (functional electrical stimulation and botulinum toxin injections), modulate neural activity (noninvasive brain stimulation), and enhance motivation (virtual reality) in an attempt to potentialize the benefits of robot-mediated training. The aim of this paper is to overview the current status of such combined treatments and to analyze the rationale behind them. PMID:29057269
Miyake, Tamon; Kobayashi, Yo; Fujie, Masakatsu G; Sugano, Shigeki
2017-07-01
Gait training robots are useful for changing gait patterns and decreasing risk of trip. Previous research has reported that decreasing duration of the assistance or guidance of the robot is beneficial for efficient gait training. Although robotic intermittent control method for assisting joint motion has been established, the effect of the robot intervention timing on change of toe clearance is unclear. In this paper, we tested different timings of applying torque to the knee, employing the intermittent control of a gait training robot to increase toe clearance throughout the swing phase. We focused on knee flexion motion and designed a gait training robot that can apply flexion torque to the knee with a wire-driven system. We used a method of timing detecting for the robot conducting torque control based on information from the hip, knee, and ankle angles to establish a non-time dependent parameter that can be used to adapt to gait change, such as gait speed. We carried out an experiment in which the conditions were four time points: starting the swing phase, lifting the foot, maintaining knee flexion, and finishing knee flexion. The results show that applying flexion torque to the knee at the time point when people start lifting their toe is effective for increasing toe clearance in the whole swing phase.
Mehrholz, J; Harvey, L A; Thomas, S; Elsner, B
2017-08-01
Systematic review about randomised trials comparing different training strategies to improve gait in people with spinal cord injuries (SCI). The aim of this systematic review was to compare the effectiveness of body-weight-supported treadmill training (BWSTT) and robotic-assisted gait training with overground gait training and other forms of physiotherapy in people with traumatic SCI. Systematic review conducted by researchers from Germany and Australia. An extensive search was conducted for randomised controlled trials involving people with traumatic SCI that compared either BWSTT or robotic-assisted gait training with overground gait training and other forms of physiotherapy. The two outcomes of interest were walking speed (m s -1 ) and walking distance (m). BWSTT and robotic-assisted gait training were analysed separately, and data were pooled across trials to derive mean between-group differences using a random-effects model. Thirteen randomised controlled trials involving 586 people were identified. Ten trials involving 462 participants compared BWSTT to overground gait training and other forms of physiotherapy, but only nine trials provided useable data. The pooled mean (95% confidence interval (CI)) between-group differences for walking speed and walking distance were -0.03 m s -1 (-0.10 to 0.04) and -7 m (-45 to 31), respectively, favouring overground gait training. Five trials involving 344 participants compared robotic-assisted gait training to overground gait training and other forms of physiotherapy but only three provided useable data. The pooled mean (95% CI) between-group differences for walking speed and walking distance were -0.04 m s -1 (95% CI -0.21 to 0.13) and -6 m (95% CI -86 to 74), respectively, favouring overground gait training. BWSTT and robotic-assisted gait training do not increase walking speed more than overground gait training and other forms of physiotherapy do, but their effects on walking distance are not clear.
Initial validation of a virtual-reality robotic simulator.
Lendvay, Thomas S; Casale, Pasquale; Sweet, Robert; Peters, Craig
2008-09-01
Robotic surgery is an accepted adjunct to minimally invasive surgery, but training is restricted to console time. Virtual-reality (VR) simulation has been shown to be effective for laparoscopic training and so we seek to validate a novel VR robotic simulator. The American Urological Association (AUA) Office of Education approved this study. Subjects enrolled in a robotics training course at the 2007 AUA annual meeting underwent skills training in a da Vinci dry-lab module and a virtual-reality robotics module which included a three-dimensional (3D) VR robotic simulator. Demographic and acceptability data were obtained, and performance metrics from the simulator were compared between experienced and nonexperienced roboticists for a ring transfer task. Fifteen subjects-four with previous robotic surgery experience and 11 without-participated. Nine subjects were still in urology training and nearly half of the group had reported playing video games. Overall performance of the da Vinci system and the simulator were deemed acceptable by a Likert scale (0-6) rating of 5.23 versus 4.69, respectively. Experienced subjects outperformed nonexperienced subjects on the simulator on three metrics: total task time (96 s versus 159 s, P < 0.02), economy of motion (1,301 mm versus 2,095 mm, P < 0.04), and time the telemanipulators spent outside of the center of the platform's workspace (4 s versus 35 s, P < 0.02). This is the first demonstration of face and construct validity of a virtual-reality robotic simulator. Further studies assessing predictive validity are ultimately required to support incorporation of VR robotic simulation into training curricula.
Effect of Gravity on Robot-Assisted Motor Training After Chronic Stroke: A Randomized Trial
Conroy, Susan S.; Whitall, Jill; Dipietro, Laura; Jones-Lush, Lauren M.; Zhan, Min; Finley, Margaret A.; Wittenberg, George F.; Krebs, Hermano I.; Bever, Christopher T.
2015-01-01
Objectives To determine the efficacy of 2 distinct 6-week robot-assisted reaching programs compared with an intensive conventional arm exercise program (ICAE) for chronic, stroke-related upper-extremity (UE) impairment. To examine whether the addition of robot-assisted training out of the horizontal plane leads to improved outcomes. Design Randomized controlled trial, single-blinded, with 12-week follow-up. Setting Research setting in a large medical center. Participants Adults (N=62) with chronic, stroke-related arm weakness stratified by impairment severity using baseline UE motor assessments. Interventions Sixty minutes, 3 times a week for 6 weeks of robot-assisted planar reaching (gravity compensated), combined planar with vertical robot-assisted reaching, or intensive conventional arm exercise program. Main Outcome Measure UE Fugl-Meyer Assessment (FMA) mean change from baseline to final training. Results All groups showed modest gains in the FMA from baseline to final with no significant between group differences. Most change occurred in the planar robot group (mean change ± SD, 2.94± 0.77; 95% confidence interval [CI], 1.40 – 4.47). Participants with greater motor impairment (n=41) demonstrated a larger difference in response (mean change ± SD, 2.29±0.72; 95% CI, 0.85–3.72) for planar robot-assisted exercise compared with the intensive conventional arm exercise program (mean change ± SD, 0.43±0.72; 95% CI, −1.00 to 1.86). Conclusions Chronic UE deficits because of stroke are responsive to intensive motor task training. However, training outside the horizontal plane in a gravity present environment using a combination of vertical with planar robots was not superior to training with the planar robot alone. PMID:21849168
Ozaki, Kenichi; Kondo, Izumi; Hirano, Satoshi; Kagaya, Hitoshi; Saitoh, Eiichi; Osawa, Aiko; Fujinori, Yoichi
2017-11-01
To examine the efficacy of postural strategy training using a balance exercise assist robot (BEAR) as compared with conventional balance training for frail older adults. The present study was designed as a cross-over trial without a washout term. A total of 27 community-dwelling frail or prefrail elderly residents (7 men, 20 women; age range 65-85 years) were selected from a volunteer sample. Two exercises were prepared for interventions: robotic exercise moving the center of gravity by the balance exercise assist robot system; and conventional balance training combining muscle-strengthening exercise, postural strategy training and applied motion exercise. Each exercise was carried out twice a week for 6 weeks. Participants were allocated randomly to either the robotic exercise first group or the conventional balance exercise first group. preferred and maximal gait speeds, tandem gait speeds, timed up-and-go test, functional reach test, functional base of support, center of pressure, and muscle strength of the lower extremities were assessed before and after completion of each exercise program. Robotic exercise achieved significant improvements for tandem gait speed (P = 0.012), functional reach test (P = 0.002), timed up-and-go test (P = 0.023) and muscle strength of the lower extremities (P = 0.001-0.030) compared with conventional exercise. In frail or prefrail older adults, robotic exercise was more effective for improving dynamic balance and lower extremity muscle strength than conventional exercise. These findings suggest that postural strategy training with the balance exercise assist robot is effective to improve the gait instability and muscle weakness often seen in frail older adults. Geriatr Gerontol Int 2017; 17: 1982-1990. © 2017 The Authors. Geriatrics & Gerontology International published by John Wiley & Sons Australia, Ltd on behalf of Japan Geriatrics Society.
Liao, Wan-Wen; Wu, Ching-Yi; Hsieh, Yu-Wei; Lin, Keh-Chung; Chang, Wan-Ying
2012-02-01
To compare the outcome of robot-assisted therapy with dose-matched active control therapy by using accelerometers to study functional recovery in chronic stroke patients. Prospective, randomized, controlled trial. Stroke units in three medical centres. Twenty patients post stroke for a mean of 22 months. Robot-assisted therapy (n = 10) or dose-matched active control therapy (n = 10). All patients received either of these two therapies for 90-105 minutes each day, 5 days per week, for four weeks. Outcome measures included arm activity ratio (the ratio of mean activity between the impaired and unimpaired arm) and scores on the Fugl-Meyer Assessment Scale, Functional Independence Measure, Motor Activity Log and ABILHAND questionnaire. The robot-assisted therapy group significantly increased motor function, hemiplegic arm activity and bilateral arm coordination (Fugl-Meyer Assessment Scale: 51.20 ± 8.82, P = 0.002; mean arm activity ratio: 0.76 ± 0.10, P = 0.026; ABILHAND questionnaire: 1.24 ± 0.28, P = 0.043) compared with the dose-matched active control group (Fugl-Meyer Assessment Scale: 40.90 ± 13.14; mean arm movement ratio: 0.69 ± 0.11; ABILHAND questionnaire: 0.95 ± 0.43). Symmetrical and bilateral robotic practice, combined with functional task training, can significantly improve motor function, arm activity, and self-perceived bilateral arm ability in patients late after stroke.
Robotic laparoscopic surgery: cost and training.
Amodeo, A; Linares Quevedo, A; Joseph, J V; Belgrano, E; Patel, H R H
2009-06-01
The advantages of minimally invasive surgery are well accepted. Shorter hospital stays, decreased postoperative pain, rapid return to preoperative activity, decreased postoperative ileus, and preserved immune function are among the benefits of the laparoscopic approach. However, the instruments of laparoscopy afford surgeons limited precision and poor ergonomics, and their use is associated with a significant learning curve and the amount of time and energy necessary to develop and maintain such advanced laparoscopic skills is not insignificant. The robotic surgery allows all laparoscopists to perform advanced laparoscopic procedures with greater ease. The potential advantages of surgical robotic systems include making advanced laparoscopic surgical procedures accessible to surgeons who do not have advanced video endoscopic training and broadening the scope of surgical procedures that can be performed using the laparoscopic method. The wristed instruments, x10 magnifications, tremor filtering, scaling of movements and three-dimensional view allow the urologist to perform the intricate dissection and anastomosis with high precision. The robot is not, however, without significant disadvantages as compared with traditional laparoscopy. These include greater expense and consumption of operating room resources such as space and the availability of skilled technical staff, complete elimination of tactile feedback, and more limited options for trocar placement. The current cost of the da Vinci system is $ 1.2 million and annual maintenance is $ 138000. Many studies suggest that depreciation and maintenance costs can be minimised if the number of robotic cases is increased. The high cost of purchasing and maintaining the instruments of the robotic system is one of its many disadvantages. The availability of the robotic systems to only a limited number of centres reduces surgical training opportunities. Hospital administrators and surgeons must define the reasons for developing a robotic surgical program: it is very important to show that robotics will add a dimension that will benefit the hospital, the patient care and institutional recognition. Another essential task to overcome is the important education of the operating room nursing staff, a significant difference between this modality and traditional surgery. Without operating room environment support, most surgeons will revert to traditional methods even after a few successful robotics cases. As the field of robotic surgery continues to grow, graduate medical education and continuing medical education programs that address the surgical robotic learning needs of residents and practicing surgeons need to be developed.
NASA Technical Reports Server (NTRS)
2002-01-01
Footage shows the crew of STS-109 (Commander Scott Altman, Pilot Duane Carey, Payload Commander John Grunsfeld, and Mission Specialists Nancy Currie, James Newman, Richard Linnehan, and Michael Massimino) during various parts of their training. Scenes show the crew's photo session, Post Landing Egress practice, training in Dome Simulator, Extravehicular Activity Training in the Neutral Buoyancy Laboratory (NBL), and using the Virtual Reality Laboratory Robotic Arm. The crew is also seen tasting food as they choose their menus for on-orbit meals.
NASA Astrophysics Data System (ADS)
Kuznetsov, D. N.; Syryamkin, V. I.
2015-11-01
Modern technologies play a very important role in our lives. It is hard to imagine how people can get along without personal computers, and companies - without powerful computer centers. Nowadays, many devices make modern medicine more effective. Medicine is developing constantly, so introduction of robots in this sector is a very promising activity. Advances in technology have influenced medicine greatly. Robotic surgery is now actively developing worldwide. Scientists have been carrying out research and practical attempts to create robotic surgeons for more than 20 years, since the mid-80s of the last century. Robotic assistants play an important role in modern medicine. This industry is new enough and is at the early stage of development; despite this, some developments already have worldwide application; they function successfully and bring invaluable help to employees of medical institutions. Today, doctors can perform operations that seemed impossible a few years ago. Such progress in medicine is due to many factors. First, modern operating rooms are equipped with up-to-date equipment, allowing doctors to make operations more accurately and with less risk to the patient. Second, technology has enabled to improve the quality of doctors' training. Various types of robots exist now: assistants, military robots, space, household and medical, of course. Further, we should make a detailed analysis of existing types of robots and their application. The purpose of the article is to illustrate the most popular types of robots used in medicine.
2014-01-01
Background In incomplete spinal cord injury (iSCI), sensorimotor impairments result in severe limitations to ambulation. To improve walking capacity, physical therapies using robotic-assisted locomotor devices, such as the Lokomat, have been developed. Following locomotor training, an improvement in gait capabilities—characterized by increases in the over-ground walking speed and endurance—is generally observed in patients. To better understand the mechanisms underlying these improvements, we studied the effects of Lokomat training on impaired ankle voluntary movement, known to be an important limiting factor in gait for iSCI patients. Methods Fifteen chronic iSCI subjects performed twelve 1-hour sessions of Lokomat training over the course of a month. The voluntary movement was qualified by measuring active range of motion, maximal velocity peak and trajectory smoothness for the spastic ankle during a movement from full plantar-flexion (PF) to full dorsi-flexion (DF) at the patient’s maximum speed. Dorsi- and plantar-flexor muscle strength was quantified by isometric maximal voluntary contraction (MVC). Clinical assessments were also performed using the Timed Up and Go (TUG), the 10-meter walk (10MWT) and the 6-minute walk (6MWT) tests. All evaluations were performed both before and after the training and were compared to a control group of fifteen iSCI patients. Results After the Lokomat training, the active range of motion, the maximal velocity, and the movement smoothness were significantly improved in the voluntary movement. Patients also exhibited an improvement in the MVC for their ankle dorsi- and plantar-flexor muscles. In terms of functional activity, we observed an enhancement in the mobility (TUG) and the over-ground gait velocity (10MWT) with training. Correlation tests indicated a significant relationship between ankle voluntary movement performance and the walking clinical assessments. Conclusions The improvements of the kinematic and kinetic parameters of the ankle voluntary movement, and their correlation with the functional assessments, support the therapeutic effect of robotic-assisted locomotor training on motor impairment in chronic iSCI. PMID:24684813
Communication and knowledge sharing in human-robot interaction and learning from demonstration.
Koenig, Nathan; Takayama, Leila; Matarić, Maja
2010-01-01
Inexpensive personal robots will soon become available to a large portion of the population. Currently, most consumer robots are relatively simple single-purpose machines or toys. In order to be cost effective and thus widely accepted, robots will need to be able to accomplish a wide range of tasks in diverse conditions. Learning these tasks from demonstrations offers a convenient mechanism to customize and train a robot by transferring task related knowledge from a user to a robot. This avoids the time-consuming and complex process of manual programming. The way in which the user interacts with a robot during a demonstration plays a vital role in terms of how effectively and accurately the user is able to provide a demonstration. Teaching through demonstrations is a social activity, one that requires bidirectional communication between a teacher and a student. The work described in this paper studies how the user's visual observation of the robot and the robot's auditory cues affect the user's ability to teach the robot in a social setting. Results show that auditory cues provide important knowledge about the robot's internal state, while visual observation of a robot can hinder an instructor due to incorrect mental models of the robot and distractions from the robot's movements. Copyright © 2010. Published by Elsevier Ltd.
Update on laparoscopic, robotic, and minimally invasive vaginal surgery for pelvic floor repair.
Ross, J W; Preston, M R
2009-06-01
Advanced laparoscopic surgery marked the beginning of minimally invasive pelvic surgery. This technique lead to the development of laparoscopic hysterectomy, colposuspension, paravaginal repair, uterosacral suspension, and sacrocolpopexy without an abdominal incision. With laparoscopy there is a significant decrease in postoperative pain, shorter length of hospital stay, and a faster return to normal activities. These advantages made laparoscopy very appealing to patients. Advanced laparoscopy requires a special set of surgical skills and in the early phase of development training was not readily available. Advanced laparoscopy was developed by practicing physicians, instead of coming down through the more usual academic channels. The need for special training did hinder widespread acceptance. Nonetheless by physician to physician training and society training courses it has continued to grow and now has been incorporated in most medical school curriculums. In the last few years there has been new interest in laparoscopy because of the development of robotic assistance. The 3D vision and 720 degree articulating arms with robotics have made suture intensive procedures much easier. Laparosco-pic robotic-assisted sacrocolpopexy is in the reach of most surgeons. This field is so new that there is very little data to evaluate at this time. There are short comings with laparoscopy and even with robotic-assisted procedures it is not the cure all for pelvic floor surgery. Laparoscopic procedures are long and many patients requiring pelvic floor surgery have medical conditions preventing long anesthesia. Minimally invasive vaginal surgery has developed from the concept of tissue replacement by synthetic mesh. Initially sheets of synthetic mesh were tailored by physicians to repair the anterior and posterior vaginal compartment. The use of mesh by general surgeons for hernia repair has served as a model for urogynecology. There have been rapid improvements in biomaterials and specialized kits have been developed by industry. The purpose of this article is to present an update in urogynecologic laparoscopy, robotic surgery, and minimally invasive vaginal surgery.
Neural-Network Control Of Prosthetic And Robotic Hands
NASA Technical Reports Server (NTRS)
Buckley, Theresa M.
1991-01-01
Electronic neural networks proposed for use in controlling robotic and prosthetic hands and exoskeletal or glovelike electromechanical devices aiding intact but nonfunctional hands. Specific to patient, who activates grasping motion by voice command, by mechanical switch, or by myoelectric impulse. Patient retains higher-level control, while lower-level control provided by neural network analogous to that of miniature brain. During training, patient teaches miniature brain to perform specialized, anthropomorphic movements unique to himself or herself.
Qiu, Qinyin; Ramirez, Diego A; Saleh, Soha; Fluet, Gerard G; Parikh, Heta D; Kelly, Donna; Adamovich, Sergei V
2009-11-16
We hypothesize that the integration of virtual reality (VR) with robot assisted rehabilitation could be successful if applied to children with hemiparetic CP. The combined benefits of increased attention provided by VR and the larger training stimulus afforded by adaptive robotics may increase the beneficial effects of these two approaches synergistically. This paper will describe the NJIT-RAVR system, which combines adaptive robotics with complex VR simulations for the rehabilitation of upper extremity impairments and function in children with CP and examine the feasibility of this system in the context of a two subject training study. The NJIT-RAVR system consists of the Haptic Master, a 6 degrees of freedom, admittance controlled robot and a suite of rehabilitation simulations that provide adaptive algorithms for the Haptic Master, allowing the user to interact with rich virtual environments. Two children, a ten year old boy and a seven year old girl, both with spastic hemiplegia secondary to Cerebral Palsy were recruited from the outpatient center of a comprehensive pediatric rehabilitation facility. Subjects performed a battery of clinical testing and kinematic measurements of reaching collected by the NJIT-RAVR system. Subjects trained with the NJIT-RAVR System for one hour, 3 days a week for three weeks. The subjects played a combination of four or five simulations depending on their therapeutic goals, tolerances and preferences. Games were modified to increase difficulty in order to challenge the subjects as their performance improved. The testing battery was repeated following the training period. Both participants completed 9 hours of training in 3 weeks. No untoward events occurred and no adverse responses to treatment or complaints of cyber sickness were reported. One participant showed improvements in overall performance on the functional aspects of the testing battery. The second subject made improvements in upper extremity active range of motion and in kinematic measures of reaching movements. We feel that this study establishes the feasibility of integrating robotics and rich virtual environments to address functional limitations and decreased motor performance in children with mild to moderate cerebral palsy.
Pilot Validation Study of the European Association of Urology Robotic Training Curriculum.
Volpe, Alessandro; Ahmed, Kamran; Dasgupta, Prokar; Ficarra, Vincenzo; Novara, Giacomo; van der Poel, Henk; Mottrie, Alexandre
2015-08-01
The development of structured and validated training curricula is one of the current priorities in robot-assisted urological surgery. To establish the feasibility, acceptability, face validity, and educational impact of a structured training curriculum for robot-assisted radical prostatectomy (RARP), and to assess improvements in performance and ability to perform RARP after completion of the curriculum. A 12-wk training curriculum was developed based on an expert panel discussion and used to train ten fellows from major European teaching institutions. The curriculum included: (1) e-learning, (2) 1 wk of structured simulation-based training (virtual reality synthetic, animal, and cadaveric platforms), and (3) supervised modular training for RARP. The feasibility, acceptability, face validity, and educational impact were assessed using quantitative surveys. Improvement in the technical skills of participants over the training period was evaluated using the inbuilt validated assessment metrics on the da Vinci surgical simulator (dVSS). A final RARP performed by fellows on completion of their training was assessed using the Global Evaluative Assessment of Robotic Skills (GEARS) score and generic and procedure-specific scoring criteria. The median baseline experience of participants as console surgeon was 4 mo (interquartile range [IQR] 0-6.5 mo). All participants completed the curriculum and were involved in a median of 18 RARPs (IQR 14-36) during modular training. The overall score for dVSS tasks significantly increased over the training period (p<0.001-0.005). At the end of the curriculum, eight fellows (80%) were deemed able by their mentors to perform a RARP independently, safely, and effectively. At assessment of the final RARP, the participants achieved an average score ≥4 (scale 1-5) for all domains using the GEARS scale and an average score >10 (scale 4-16) for all procedural steps using a generic dedicated scoring tool. In performance comparison using this scoring tool, the experts significantly outperformed the fellows (mean score for all steps 13.6 vs 11). The European robot-assisted urologic training curriculum is acceptable, valid, and effective for training in RARP. This study shows that a 12-wk structured training program including simulation-based training and mentored training in the operating room allows surgeons with limited robotic experience to increase their robotic skills and their ability to perform the surgical steps of robot-assisted radical prostatectomy. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Does Lego Training Stimulate Pupils' Ability to Solve Logical Problems?
ERIC Educational Resources Information Center
Lindh, Jorgen; Holgersson, Thomas
2007-01-01
The purpose of this study is to investigate the effect of a one-year regular robotic toys (lego) training on school pupils' performance. The underlying pedagogical perspective is the "constructionist theory," where the main idea is that knowledge is constructed in the mind of the pupil by active learning. The investigation has been made…
Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients
2017-01-01
Objective To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Methods Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Results Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. Conclusion There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method. PMID:28971037
From dV-Trainer to Real Robotic Console: The Limitations of Robotic Skill Training.
Yang, Kun; Zhen, Hang; Hubert, Nicolas; Perez, Manuela; Wang, Xing Huan; Hubert, Jacques
To investigate operators' performance quality, mental stress, and ergonomic habits through a training curriculum on robotic simulators. Forty volunteers without robotic surgery experience were recruited to practice 2 exercises on a dV-Trainer (dVT) for 14 hours. The simulator software (M-score a ) provided an automatic evaluation of the overall score for the surgeons' performance. Each participant provided a subjective difficulty score (validity to be proven) for each exercise. Their ergonomic habits were evaluated based on the workspace range and armrest load-validated criteria for evaluating the proficiency of using the armrest. They then repeated the same tasks on a da Vinci Surgical Skill Simulator for a final-level test. Their final scores were compared with their initial scores and the scores of 5 experts on the da Vinci Surgical Skill Simulator. A total of 14 hours of training on the dVT significantly improved the surgeons' performance scores to the expert level with a significantly reduced workload, but their ergonomic score was still far from the expert level. Sufficient training on the dVT improves novices' performance, reduces psychological stress, and inculcates better ergonomic habits. Among the evaluated criteria, novices had the most difficulty in achieving expert levels of ergonomic skills. The training benefits of robotic surgery simulators should be determined with quantified variables. The detection of the limitations during robotic training curricula could guide the targeted training and improve the training effect. Copyright © 2017. Published by Elsevier Inc.
How does a surgeon’s brain buzz? An EEG coherence study on the interaction between humans and robot
2013-01-01
Introduction In humans, both primary and non-primary motor areas are involved in the control of voluntary movements. However, the dynamics of functional coupling among different motor areas have not been fully clarified yet. There is to date no research looking to the functional dynamics in the brain of surgeons working in laparoscopy compared with those trained and working in robotic surgery. Experimental procedures We enrolled 16 right-handed trained surgeons and assessed changes in intra- and inter-hemispheric EEG coherence with a 32-channels device during the same motor task with either a robotic or a laparoscopic approach. Estimates of auto and coherence spectra were calculated by a fast Fourier transform algorithm implemented on Matlab 5.3. Results We found increase of coherence in surgeons performing laparoscopy, especially in theta and lower alpha activity, in all experimental conditions (M1 vs. SMA, S1 vs. SMA, S1 vs. pre-SMA and M1 vs. S1; p < 0.001). Conversely, an increase in inter-hemispheric coherence in upper alpha and beta band was found in surgeons using the robotic procedure (right vs. left M1, right vs. left S1, right pre-SMA vs. left M1, left pre-SMA vs. right M1; p < 0.001). Discussion Our data provide a semi-quantitative evaluation of dynamics in functional coupling among different cortical areas in skilled surgeons performing laparoscopy or robotic surgery. These results suggest that motor and non-motor areas are differently activated and coordinated in surgeons performing the same task with different approaches. To the best of our knowledge, this is the first study that tried to assess semi-quantitative differences during the interaction between normal human brain and robotic devices. PMID:23607324
How does a surgeon's brain buzz? An EEG coherence study on the interaction between humans and robot.
Bocci, Tommaso; Moretto, Carlo; Tognazzi, Silvia; Briscese, Lucia; Naraci, Megi; Leocani, Letizia; Mosca, Franco; Ferrari, Mauro; Sartucci, Ferdinando
2013-04-22
In humans, both primary and non-primary motor areas are involved in the control of voluntary movements. However, the dynamics of functional coupling among different motor areas have not been fully clarified yet. There is to date no research looking to the functional dynamics in the brain of surgeons working in laparoscopy compared with those trained and working in robotic surgery. We enrolled 16 right-handed trained surgeons and assessed changes in intra- and inter-hemispheric EEG coherence with a 32-channels device during the same motor task with either a robotic or a laparoscopic approach. Estimates of auto and coherence spectra were calculated by a fast Fourier transform algorithm implemented on Matlab 5.3. We found increase of coherence in surgeons performing laparoscopy, especially in theta and lower alpha activity, in all experimental conditions (M1 vs. SMA, S1 vs. SMA, S1 vs. pre-SMA and M1 vs. S1; p < 0.001). Conversely, an increase in inter-hemispheric coherence in upper alpha and beta band was found in surgeons using the robotic procedure (right vs. left M1, right vs. left S1, right pre-SMA vs. left M1, left pre-SMA vs. right M1; p < 0.001). Our data provide a semi-quantitative evaluation of dynamics in functional coupling among different cortical areas in skilled surgeons performing laparoscopy or robotic surgery. These results suggest that motor and non-motor areas are differently activated and coordinated in surgeons performing the same task with different approaches. To the best of our knowledge, this is the first study that tried to assess semi-quantitative differences during the interaction between normal human brain and robotic devices.
Performance-based robotic assistance during rhythmic arm exercises.
Leconte, Patricia; Ronsse, Renaud
2016-09-13
Rhythmic and discrete upper-limb movements are two fundamental motor primitives controlled by different neural pathways, at least partially. After stroke, both primitives can be impaired. Both conventional and robot-assisted therapies mainly train discrete functional movements like reaching and grasping. However, if the movements form two distinct neural and functional primitives, both should be trained to recover the complete motor repertoire. Recent studies show that rhythmic movements tend to be less impaired than discrete ones, so combining both movement types in therapy could support the execution of movements with a higher degree of impairment by movements that are performed more stably. A new performance-based assistance method was developed to train rhythmic movements with a rehabilitation robot. The algorithm uses the assist-as-needed paradigm by independently assessing and assisting movement features of smoothness, velocity, and amplitude. The method relies on different building blocks: (i) an adaptive oscillator captures the main movement harmonic in state variables, (ii) custom metrics measure the movement performance regarding the three features, and (iii) adaptive forces assist the patient. The patient is encouraged to improve performance regarding these three features with assistance forces computed in parallel to each other. The method was tested with simulated jerky signals and a pilot experiment with two stroke patients, who were instructed to make circular movements with an end-effector robot with assistance during half of the trials. Simulation data reveal sensitivity of the metrics for assessing the features while limiting interference between them. The assistance's effectiveness with stroke patients is established since it (i) adapts to the patient's real-time performance, (ii) improves patient motor performance, and (iii) does not lead the patient to slack. The smoothness assistance was by far the most used by both patients, while it provided no active mechanical work to the patient on average. Our performance-based assistance method for training rhythmic movements is a viable candidate to complement robot-assisted upper-limb therapies for training a larger motor repertoire.
Robotics, motor learning, and neurologic recovery.
Reinkensmeyer, David J; Emken, Jeremy L; Cramer, Steven C
2004-01-01
Robotic devices are helping shed light on human motor control in health and injury. By using robots to apply novel force fields to the arm, investigators are gaining insight into how the nervous system models its external dynamic environment. The nervous system builds internal models gradually by experience and uses them in combination with impedance and feedback control strategies. Internal models are robust to environmental and neural noise, generalized across space, implemented in multiple brain regions, and developed in childhood. Robots are also being used to assist in repetitive movement practice following neurologic injury, providing insight into movement recovery. Robots can haptically assess sensorimotor performance, administer training, quantify amount of training, and improve motor recovery. In addition to providing insight into motor control, robotic paradigms may eventually enhance motor learning and rehabilitation beyond the levels possible with conventional training techniques.
Robotic surgery in Italy national survey (2011).
Santoro, Eugenio; Pansadoro, Vito
2013-03-01
Robotic surgery in Italy has become a clinical reality that is gaining increasing acceptance. As of 2011 after the United States, Italy together with Germany is the country with the largest number of active Robotic centers, 46, and da Vinci Robots installed, with at least 116 operators already trained. The number of interventions performed in Italy in 2011 exceeded 6,000 and in 2010 were 4,784, with prevalence for urology, general surgery and gynecology, however these interventions have also begun to be applied in other fields such as cervicofacial, cardiothoracic and pediatric surgery. In Italy Robotic centers are mostly located in Northern Italy, while in the South there are only a few centers, and four regions are lacking altogether. Of the 46 centers which were started in 1999, the vast majority is still operational and almost half handle over 200 cases a year. The quality of the work is also especially high with large diffusion of radical prostatectomy in urology and liver resection and colic in general surgery. The method is very well accepted among operators, over 80 %, and among patients, over 95 %. From the analysis of world literature and a survey carried out in Italy, Robotic surgery, which at the moment could be better defined as telesurgery, represents a significant advantage for operators and a consistent gain for the patient. However, it still has important limits such as high cost and non-structured training of operators.
van der Meijden, O A J; Schijven, M P
2009-06-01
Virtual reality (VR) as surgical training tool has become a state-of-the-art technique in training and teaching skills for minimally invasive surgery (MIS). Although intuitively appealing, the true benefits of haptic (VR training) platforms are unknown. Many questions about haptic feedback in the different areas of surgical skills (training) need to be answered before adding costly haptic feedback in VR simulation for MIS training. This study was designed to review the current status and value of haptic feedback in conventional and robot-assisted MIS and training by using virtual reality simulation. A systematic review of the literature was undertaken using PubMed and MEDLINE. The following search terms were used: Haptic feedback OR Haptics OR Force feedback AND/OR Minimal Invasive Surgery AND/OR Minimal Access Surgery AND/OR Robotics AND/OR Robotic Surgery AND/OR Endoscopic Surgery AND/OR Virtual Reality AND/OR Simulation OR Surgical Training/Education. The results were assessed according to level of evidence as reflected by the Oxford Centre of Evidence-based Medicine Levels of Evidence. In the current literature, no firm consensus exists on the importance of haptic feedback in performing minimally invasive surgery. Although the majority of the results show positive assessment of the benefits of force feedback, results are ambivalent and not unanimous on the subject. Benefits are least disputed when related to surgery using robotics, because there is no haptic feedback in currently used robotics. The addition of haptics is believed to reduce surgical errors resulting from a lack of it, especially in knot tying. Little research has been performed in the area of robot-assisted endoscopic surgical training, but results seem promising. Concerning VR training, results indicate that haptic feedback is important during the early phase of psychomotor skill acquisition.
Knaepen, Kristel; Mierau, Andreas; Swinnen, Eva; Fernandez Tellez, Helio; Michielsen, Marc; Kerckhofs, Eric; Lefeber, Dirk; Meeusen, Romain
2015-01-01
In order to determine optimal training parameters for robot-assisted treadmill walking, it is essential to understand how a robotic device interacts with its wearer, and thus, how parameter settings of the device affect locomotor control. The aim of this study was to assess the effect of different levels of guidance force during robot-assisted treadmill walking on cortical activity. Eighteen healthy subjects walked at 2 km.h-1 on a treadmill with and without assistance of the Lokomat robotic gait orthosis. Event-related spectral perturbations and changes in power spectral density were investigated during unassisted treadmill walking as well as during robot-assisted treadmill walking at 30%, 60% and 100% guidance force (with 0% body weight support). Clustering of independent components revealed three clusters of activity in the sensorimotor cortex during treadmill walking and robot-assisted treadmill walking in healthy subjects. These clusters demonstrated gait-related spectral modulations in the mu, beta and low gamma bands over the sensorimotor cortex related to specific phases of the gait cycle. Moreover, mu and beta rhythms were suppressed in the right primary sensory cortex during treadmill walking compared to robot-assisted treadmill walking with 100% guidance force, indicating significantly larger involvement of the sensorimotor area during treadmill walking compared to robot-assisted treadmill walking. Only marginal differences in the spectral power of the mu, beta and low gamma bands could be identified between robot-assisted treadmill walking with different levels of guidance force. From these results it can be concluded that a high level of guidance force (i.e., 100% guidance force) and thus a less active participation during locomotion should be avoided during robot-assisted treadmill walking. This will optimize the involvement of the sensorimotor cortex which is known to be crucial for motor learning. PMID:26485148
Research on Safety and Compliance of a New Lower Limb Rehabilitation Robot
Feng, Yongfei; Wang, Hongbo; Yan, Hao; Wang, Xincheng; Jin, Zhennan; Vladareanu, Luige
2017-01-01
The lower limb rehabilitation robot is an application of robotic technology for stroke people with lower limb disabilities. A new applicable and effective sitting/lying lower limb rehabilitation robot (LLR-Ro) is proposed, which has the mechanical limit protection, the electrical limit protection, and the software protection to prevent the patient from the secondary damage. Meanwhile, as a new type of the rehabilitation robots, its hip joint rotation ranges are different in the patient sitting training posture and lying training posture. The mechanical leg of the robot has a variable workspace to work in both training postures. So, if the traditional mechanical limit and the electrical limit cannot be used in the hip joint mechanism design, a follow-up limit is first proposed to improve the compatibility of human-machine motion. Besides, to eliminate the accident interaction force between the patient and LLR-Ro in the process of the passive training, an amendment impedance control strategy based on the position control is proposed to improve the compliance of the LLR-Ro. A simulation experiment and an experiment with a participant show that the passive training of LLR-Ro has compliance. © 2017 Yongfei Feng et al.
Training and outcome monitoring in robotic urologic surgery.
Liberman, Daniel; Trinh, Quoc-Dien; Jeldres, Claudio; Valiquette, Luc; Zorn, Kevin C
2011-11-08
The use of robot-assisted laparoscopic technology is rapidly expanding, with applicability in numerous disciplines of surgery. Training to perform robot-assisted laparoscopic urological procedures requires a motivated learner, a motivated teacher or proctor, a curriculum with stepwise learning objectives, and regular access to a training robot. In light of the many constraints that limit surgical training, animal models should be utilized to quantifiably improve the surgical skills of residents and surgical fellows, before these skills are put into practice on patients. A system based on appropriate supervision, graduated responsibility, real-time feedback, and objective measure of progress has proven to be safe and effective. Surgical team education directed towards cohesion is perhaps the most important aspect of training. At present, there are very few published guidelines for the safe introduction of robotic urologic surgery at an institution. Increasing evidence demonstrates the effects of learning curve and surgical volume on oncological and functional outcomes in robotic surgery (RS). This necessitates the introduction of mechanisms and guidelines by which trainee surgeons can attain a sufficient level of skill, without compromising the safety of patients. Guidelines for outcome monitoring following RS should be developed, to ensure patient safety and sufficient baseline surgeon skill.
Research on Safety and Compliance of a New Lower Limb Rehabilitation Robot
Yan, Hao; Wang, Xincheng; Jin, Zhennan; Vladareanu, Luige
2017-01-01
The lower limb rehabilitation robot is an application of robotic technology for stroke people with lower limb disabilities. A new applicable and effective sitting/lying lower limb rehabilitation robot (LLR-Ro) is proposed, which has the mechanical limit protection, the electrical limit protection, and the software protection to prevent the patient from the secondary damage. Meanwhile, as a new type of the rehabilitation robots, its hip joint rotation ranges are different in the patient sitting training posture and lying training posture. The mechanical leg of the robot has a variable workspace to work in both training postures. So, if the traditional mechanical limit and the electrical limit cannot be used in the hip joint mechanism design, a follow-up limit is first proposed to improve the compatibility of human-machine motion. Besides, to eliminate the accident interaction force between the patient and LLR-Ro in the process of the passive training, an amendment impedance control strategy based on the position control is proposed to improve the compliance of the LLR-Ro. A simulation experiment and an experiment with a participant show that the passive training of LLR-Ro has compliance. PMID:29065571
Sale, Patrizio; Stocchi, Fabrizio; Galafate, Daniele; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Galli, Manuela; Foti, Calogero; Franceschini, Marco
2014-01-01
Background and Purpose: Progressive supranuclear palsy (PSP) is a rare neurodegenerative disease clinically characterized by prominent axial extrapyramidal motor symptoms with frequent falls. Over the last years the introduction of robotic technologies to recover lower limb function has been greatly employed in the rehabilitative practice. This observational trial is aimed at investigating the changes in the main spatiotemporal following end-effector robot training in people with PSP. Method: Pilot observational trial. Participants: Five cognitively intact participants with PSP and gait disorders. Interventions: Patients were submitted to a rehabilitative program of robot-assisted walking sessions for 45 min, 5 times a week for 4 weeks. Main outcome measures: The spatiotemporal parameters at the beginning (T0) and at the end of treatment (T1) were recorded by a gait analysis laboratory. Results: Robot training was feasible, acceptable and safe and all participants completed the prescribed training sessions. All patients showed an improvement in the gait spatiotemporal index (Mean velocity, Cadence, Step length, and Step width) (T0 vs. T1). Conclusions: Robot training is a feasible and safe form of rehabilitation for cognitively intact people with PSP. The lack of side effects and the positive results in the gait parameter index in all patients support the recommendation to extend the trials of this treatment. Further investigation regarding the effectiveness of robot training in time is necessary. Trial registration: ClinicalTrials.gov NCT01668407. PMID:24860459
Carpinella, Ilaria; Cattaneo, Davide; Bertoni, Rita; Ferrarin, Maurizio
2012-05-01
In this pilot study, we compared two protocols for robot-based rehabilitation of upper limb in multiple sclerosis (MS): a protocol involving reaching tasks (RT) requiring arm transport only and a protocol requiring both objects' reaching and manipulation (RMT). Twenty-two MS subjects were assigned to RT or RMT group. Both protocols consisted of eight sessions. During RT training, subjects moved the handle of a planar robotic manipulandum toward circular targets displayed on a screen. RMT protocol required patients to reach and manipulate real objects, by moving the robotic arm equipped with a handle which left the hand free for distal tasks. In both trainings, the robot generated resistive and perturbing forces. Subjects were evaluated with clinical and instrumental tests. The results confirmed that MS patients maintained the ability to adapt to the robot-generated forces and that the rate of motor learning increased across sessions. Robot-therapy significantly reduced arm tremor and improved arm kinematics and functional ability. Compared to RT, RMT protocol induced a significantly larger improvement in movements involving grasp (improvement in Grasp ARAT sub-score: RMT 77.4%, RT 29.5%, p=0.035) but not precision grip. Future studies are needed to evaluate if longer trainings and the use of robotic handles would significantly improve also fine manipulation.
Hussain, Asif; Budhota, Aamani; Hughes, Charmayne Mary Lee; Dailey, Wayne D; Vishwanath, Deshmukh A; Kuah, Christopher W K; Yam, Lester H L; Loh, Yong J; Xiang, Liming; Chua, Karen S G; Burdet, Etienne; Campolo, Domenico
2016-01-01
Technology aided measures offer a sensitive, accurate and time-efficient approach for the assessment of sensorimotor function after neurological insult compared to standard clinical assessments. This study investigated the sensitivity of robotic measures to capture differences in planar reaching movements as a function of neurological status (stroke, healthy), direction (front, ipsilateral, contralateral), movement segment (outbound, inbound), and time (baseline, post-training, 2-week follow-up) using a planar, two-degrees of freedom, robotic-manipulator (H-Man). Twelve chronic stroke (age: 55 ± 10.0 years, 5 female, 7 male, time since stroke: 11.2 ± 6.0 months) and nine aged-matched healthy participants (age: 53 ± 4.3 years, 5 female, 4 male) participated in this study. Both healthy and stroke participants performed planar reaching movements in contralateral, ipsilateral and front directions with the H-Man, and the robotic measures, spectral arc length (SAL), normalized time to peak velocities ( T peakN ), and root-mean square error (RMSE) were evaluated. Healthy participants went through a one-off session of assessment to investigate the baseline. Stroke participants completed a 2-week intensive robotic training plus standard arm therapy (8 × 90 min sessions). Motor function for stroke participants was evaluated prior to training (baseline, week-0), immediately following training (post-training, week-2), and 2-weeks after training (follow-up, week-4) using robotic assessment and the clinical measures Fugl-Meyer Assessment (FMA), Activity-Research-Arm Test (ARAT), and grip-strength. Robotic assessments were able to capture differences due to neurological status, movement direction, and movement segment. Movements performed by stroke participants were less-smooth, featured longer T peakN , and larger RMSE values, compared to healthy controls. Significant movement direction differences were observed, with improved reaching performance for the front, compared to ipsilateral and contralateral movement directions. There were group differences depending on movement segment. Outbound reaching movements were smoother and featured longer T peakN values than inbound movements for control participants, whereas SAL, T peakN , and RMSE values were similar regardless of movement segment for stroke patients. Significant change in performance was observed between initial and post-assessments using H-Man in stroke participants, compared to conventional scales which showed no significant difference. Results of the study indicate the potential of H-Man as a sensitive tool for tracking changes in performance compared to ordinal scales (i.e., FM, ARAT).
Hierarchical Compliance Control of a Soft Ankle Rehabilitation Robot Actuated by Pneumatic Muscles.
Liu, Quan; Liu, Aiming; Meng, Wei; Ai, Qingsong; Xie, Sheng Q
2017-01-01
Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance control method of a soft ankle rehabilitation robot that is driven by four PMAs configured in parallel to enable three degrees of freedom movement of the ankle joint. A new hierarchical compliance control structure, including a low-level compliance adjustment controller in joint space and a high-level admittance controller in task space, is designed. An adaptive compliance control paradigm is further developed by taking into account patient's active contribution and movement ability during a previous period of time, in order to provide robot assistance only when it is necessarily required. Experiments on healthy and impaired human subjects were conducted to verify the adaptive hierarchical compliance control scheme. The results show that the robot hierarchical compliance can be online adjusted according to the participant's assessment. The robot reduces its assistance output when participants contribute more and vice versa , thus providing a potentially feasible solution to the patient-in-loop cooperative training strategy.
Hierarchical Compliance Control of a Soft Ankle Rehabilitation Robot Actuated by Pneumatic Muscles
Liu, Quan; Liu, Aiming; Meng, Wei; Ai, Qingsong; Xie, Sheng Q.
2017-01-01
Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance control method of a soft ankle rehabilitation robot that is driven by four PMAs configured in parallel to enable three degrees of freedom movement of the ankle joint. A new hierarchical compliance control structure, including a low-level compliance adjustment controller in joint space and a high-level admittance controller in task space, is designed. An adaptive compliance control paradigm is further developed by taking into account patient’s active contribution and movement ability during a previous period of time, in order to provide robot assistance only when it is necessarily required. Experiments on healthy and impaired human subjects were conducted to verify the adaptive hierarchical compliance control scheme. The results show that the robot hierarchical compliance can be online adjusted according to the participant’s assessment. The robot reduces its assistance output when participants contribute more and vice versa, thus providing a potentially feasible solution to the patient-in-loop cooperative training strategy. PMID:29255412
Improved motor performance in chronic spinal cord injury following upper-limb robotic training.
Cortes, Mar; Elder, Jessica; Rykman, Avrielle; Murray, Lynda; Avedissian, Manuel; Stampas, Argyrios; Thickbroom, Gary W; Pascual-Leone, Alvaro; Krebs, Hermano Igo; Valls-Sole, Josep; Edwards, Dylan J
2013-01-01
Recovering upper-limb motor function has important implications for improving independence of patients with tetraplegia after traumatic spinal cord injury (SCI). To evaluate the feasibility, safety and effectiveness of robotic-assisted training of upper limb in a chronic SCI population. A total of 10 chronic tetraplegic SCI patients (C4 to C6 level of injury, American Spinal Injury Association Impairment Scale, A to D) participated in a 6-week wrist-robot training protocol (1 hour/day 3 times/week). The following outcome measures were recorded at baseline and after the robotic training: a) motor performance, assessed by robot-measured kinematics, b) corticospinal excitability measured by transcranial magnetic stimulation (TMS), and c) changes in clinical scales: motor strength (Upper extremity motor score), pain level (Visual Analog Scale) and spasticity (Modified Ashworth scale). No adverse effects were observed during or after the robotic training. Statistically significant improvements were found in motor performance kinematics: aim (pre 1.17 ± 0.11 raduans, post 1.03 ± 0.08 raduans, p = 0.03) and smoothness of movement (pre 0.26 ± 0.03, post 0.31 ± 0.02, p = 0.03). These changes were not accompanied by changes in upper-extremity muscle strength or corticospinal excitability. No changes in pain or spasticity were found. Robotic-assisted training of the upper limb over six weeks is a feasible and safe intervention that can enhance movement kinematics without negatively affecting pain or spasticity in chronic SCI. In addition, robot-assisted devices are an excellent tool to quantify motor performance (kinematics) and can be used to sensitively measure changes after a given rehabilitative intervention.
Kinnaird, Catherine R.; Holleran, Carey L.; Rafferty, Miriam R.; Rodriguez, Kelly S.; Cain, Julie B.
2012-01-01
Background Robotic-assisted locomotor training has demonstrated some efficacy in individuals with neurological injury and is slowly gaining clinical acceptance. Both exoskeletal devices, which control individual joint movements, and elliptical devices, which control endpoint trajectories, have been utilized with specific patient populations and are available commercially. No studies have directly compared training efficacy or patient performance during stepping between devices. Objective The purpose of this study was to evaluate kinematic, electromyographic (EMG), and metabolic responses during elliptical- and exoskeletal-assisted stepping in individuals with incomplete spinal cord injury (SCI) compared with therapist-assisted stepping. Design A prospective, cross-sectional, repeated-measures design was used. Methods Participants with incomplete SCI (n=11) performed 3 separate bouts of exoskeletal-, elliptical-, or therapist-assisted stepping. Unilateral hip and knee sagittal-plane kinematics, lower-limb EMG recordings, and oxygen consumption were compared across stepping conditions and with control participants (n=10) during treadmill stepping. Results Exoskeletal stepping kinematics closely approximated normal gait patterns, whereas significantly greater hip and knee flexion postures were observed during elliptical-assisted stepping. Measures of kinematic variability indicated consistent patterns in control participants and during exoskeletal-assisted stepping, whereas therapist- and elliptical-assisted stepping kinematics were more variable. Despite specific differences, EMG patterns generally were similar across stepping conditions in the participants with SCI. In contrast, oxygen consumption was consistently greater during therapist-assisted stepping. Limitations Limitations included a small sample size, lack of ability to evaluate kinetics during stepping, unilateral EMG recordings, and sagittal-plane kinematics. Conclusions Despite specific differences in kinematics and EMG activity, metabolic activity was similar during stepping in each robotic device. Understanding potential differences and similarities in stepping performance with robotic assistance may be important in delivery of repeated locomotor training using robotic or therapist assistance and for consumers of robotic devices. PMID:22700537
The robotic lumbar spine: dynamics and feedback linearization control.
Karadogan, Ernur; Williams, Robert L
2013-01-01
The robotic lumbar spine (RLS) is a 15 degree-of-freedom, fully cable-actuated robotic lumbar spine which can mimic in vivo human lumbar spine movements to provide better hands-on training for medical students. The design incorporates five active lumbar vertebrae and the sacrum, with dimensions of an average adult human spine. It is actuated by 20 cables connected to electric motors. Every vertebra is connected to the neighboring vertebrae by spherical joints. Medical schools can benefit from a tool, system, or method that will help instructors train students and assess their tactile proficiency throughout their education. The robotic lumbar spine has the potential to satisfy these needs in palpatory diagnosis. Medical students will be given the opportunity to examine their own patient that can be programmed with many dysfunctions related to the lumbar spine before they start their professional lives as doctors. The robotic lumbar spine can be used to teach and test medical students in their capacity to be able to recognize normal and abnormal movement patterns of the human lumbar spine under flexion-extension, lateral bending, and axial torsion. This paper presents the dynamics and nonlinear control of the RLS. A new approach to solve for positive and nonzero cable tensions that are also continuous in time is introduced.
Spataro, Rossella; Chella, Antonio; Allison, Brendan; Giardina, Marcello; Sorbello, Rosario; Tramonte, Salvatore; Guger, Christoph; La Bella, Vincenzo
2017-01-01
Locked-in Amyotrophic Lateral Sclerosis (ALS) patients are fully dependent on caregivers for any daily need. At this stage, basic communication and environmental control may not be possible even with commonly used augmentative and alternative communication devices. Brain Computer Interface (BCI) technology allows users to modulate brain activity for communication and control of machines and devices, without requiring a motor control. In the last several years, numerous articles have described how persons with ALS could effectively use BCIs for different goals, usually spelling. In the present study, locked-in ALS patients used a BCI system to directly control the humanoid robot NAO (Aldebaran Robotics, France) with the aim of reaching and grasping a glass of water. Four ALS patients and four healthy controls were recruited and trained to operate this humanoid robot through a P300-based BCI. A few minutes training was sufficient to efficiently operate the system in different environments. Three out of the four ALS patients and all controls successfully performed the task with a high level of accuracy. These results suggest that BCI-operated robots can be used by locked-in ALS patients as an artificial alter-ego, the machine being able to move, speak and act in his/her place. PMID:28298888
Conditional Random Fields for Activity Recognition
2008-04-01
final match. The final is never used as a training or hold out set. Table 4.1 lists the roles of the CMDragons’07 robot soccer team. The role of Goalie ...is not included because the goalie never changes roles. The classification task, which we formalize below, is to recognize robot roles from the avail...process and pull out the key information from the sensor data. Furthermore, as conditional models, CRFs do not waste modeling effort on the observations
Low-cost educational robotics applied to physics teaching in Brazil
NASA Astrophysics Data System (ADS)
Souza, Marcos A. M.; Duarte, José R. R.
2015-07-01
In this paper, we propose some of the strategies and methodologies for teaching high-school physics topics through an educational robotics show. This exhibition was part of a set of actions promoted by a Brazilian government program of incentive for teaching activities, whose primary focus is the training of teachers, the improvement of teaching in public schools, the dissemination of science, and the formation of new scientists and researchers. By means of workshops, banners and the prototyping of robotics, we were able to create a connection between the study areas and their surroundings, making learning meaningful and accessible for the students involved and contributing to their cognitive development.
Issues in intelligent robots for search and rescue
NASA Astrophysics Data System (ADS)
Casper, Jennifer L.; Micire, Mark; Murphy, Robin R.
2000-07-01
Since the 1995 Oklahoma City bombing and Kobe, Japan, earthquake, robotics researchers have been considering search and rescue as a humanitarian research domain. The recent devastation in Turkey and Taiwan, compounded with the new Robocup Rescue and AAAI Urban Search and Rescue robot competition, may encourage more research. However, roboticists generally go not have access to domain experts: the emergency workers or first providers. This paper shares our understanding of urban search and rescue, based on our active research in this area and training sessions with rescue workers from the Hillsborough County (Florida) Fire Departments. The paper is intended to be a stepping stone for roboticists entering the field.
Solazzi, Massimiliano; Loconsole, Claudio; Barsotti, Michele
2016-01-01
This paper illustrates the application of emerging technologies and human-machine interfaces to the neurorehabilitation and motor assistance fields. The contribution focuses on wearable technologies and in particular on robotic exoskeleton as tools for increasing freedom to move and performing Activities of Daily Living (ADLs). This would result in a deep improvement in quality of life, also in terms of improved function of internal organs and general health status. Furthermore, the integration of these robotic systems with advanced bio-signal driven human-machine interface can increase the degree of participation of patient in robotic training allowing to recognize user's intention and assisting the patient in rehabilitation tasks, thus representing a fundamental aspect to elicit motor learning PMID:28484314
De Luca, Alice; Giannoni, Psiche; Vernetti, Honore; Capra, Cristina; Lentino, Carmelo; Checchia, Giovanni Antonio; Casadio, Maura
2017-07-01
Robot-assisted rehabilitation of stroke survivors mainly focuses on the impaired side of the body while the role of the unimpaired side in the recovery after stroke is still controversial. The goal of this study is to investigate the influence on sitting balance and paretic arm functions of a training protocol based on movements of the unimpaired arm. Sixteen chronic stroke survivors underwent nineteen training sessions, in which they performed active movements with the unimpaired arm supported by a passive exoskeleton. Performance of the trunk and upper limbs was evaluated before treatment, after treatment and at six months follow up with clinical scales and an instrumented evaluation. A reaching test executed with the exoskeleton was used to assess changes in performance of both arms. The treatment based on the unimpaired arm's movements executed with a correct body posture led to benefits in control of the trunk and of both the trained and the untrained arm. The amount of impaired arm improvement in the Fugl-Meyer score was comparable to the outcome of robotic treatments focused directly on this arm. Our results highlight the importance of taking into account all body schema in the rehabilitation robotic program, instead of focusing only on the impaired side of the body.
Observation-based training for neuroprosthetic control of grasping by amputees.
Agashe, Harshavardhan A; Contreras-Vidal, Jose L
2014-01-01
Current brain-machine interfaces (BMIs) allow upper limb amputees to position robotic arms with a high degree of accuracy, but lack the ability to control hand pre-shaping for grasping different objects. We have previously shown that low frequency (0.1-1 Hz) time domain cortical activity recorded at the scalp via electroencephalography (EEG) encodes information about grasp pre-shaping. To transfer this technology to clinical populations such as amputees, the challenge lies in constructing BMI models in the absence of overt training hand movements. Here we show that it is possible to train BMI models using observed grasping movements performed by a robotic hand attached to amputees' residual limb. Three transradial amputees controlled the grasping motion of an attached robotic hand via their EEG, following the action-observation training phase. Over multiple sessions, subjects successfully grasped the presented object (a bottle or a credit card) in 53±16 % of trials, demonstrating the validity of the BMI models. Importantly, the validation of the BMI model was through closed-loop performance, which demonstrates generalization of the model to unseen data. These results suggest `mirror neuron system' properties captured by delta band EEG that allows neural representation for action observation to be used for action control in an EEG-based BMI system.
Evaluation of robotic cardiac surgery simulation training: A randomized controlled trial.
Valdis, Matthew; Chu, Michael W A; Schlachta, Christopher; Kiaii, Bob
2016-06-01
To compare the currently available simulation training modalities used to teach robotic surgery. Forty surgical trainees completed a standardized robotic 10-cm dissection of the internal thoracic artery and placed 3 sutures of a mitral valve annuloplasty in porcine models and were then randomized to a wet lab, a dry lab, a virtual reality lab, or a control group that received no additional training. All groups trained to a level of proficiency determined by 2 expert robotic cardiac surgeons. All assessments were evaluated using the Global Evaluative Assessment of Robotic Skills in a blinded fashion. Wet lab trainees showed the greatest improvement in time-based scoring and the objective scoring tool compared with the experts (mean, 24.9 ± 1.7 vs 24.9 ± 2.6; P = .704). The virtual reality lab improved their scores and met the level of proficiency set by our experts for all primary outcomes (mean, 24.9 ± 1.7 vs 22.8 ± 3.7; P = .103). Only the control group trainees were not able to meet the expert level of proficiency for both time-based scores and the objective scoring tool (mean, 24.9 ± 1.7 vs 11.0 ± 4.5; P < .001). The average duration of training was shortest for the dry lab and longest for the virtual reality simulation (1.6 hours vs 9.3 hours; P < .001). We have completed the first randomized controlled trial to objectively compare the different training modalities of robotic surgery. Our data demonstrate the significant benefits of wet lab and virtual reality robotic simulation training and highlight key differences in current training methods. This study can help guide training programs in investing resources in cost-effective, high-yield simulation exercises. Copyright © 2016 The American Association for Thoracic Surgery. All rights reserved.
Dulan, Genevieve; Rege, Robert V; Hogg, Deborah C; Gilberg-Fisher, Kristine K; Tesfay, Seifu T; Scott, Daniel J
2012-04-01
The authors previously developed a comprehensive, proficiency-based robotic training curriculum that aimed to address 23 unique skills identified via task deconstruction of robotic operations. The purpose of this study was to determine the content and face validity of this curriculum. Expert robotic surgeons (n = 12) rated each deconstructed skill regarding relevance to robotic operations, were oriented to the curricular components, performed 3 to 5 repetitions on the 9 exercises, and rated each exercise. In terms of content validity, experts rated all 23 deconstructed skills as highly relevant (4.5 on a 5-point scale). Ratings for the 9 inanimate exercises indicated moderate to thorough measurement of designated skills. For face validity, experts indicated that each exercise effectively measured relevant skills (100% agreement) and was highly effective for training and assessment (4.5 on a 5-point scale). These data indicate that the 23 deconstructed skills accurately represent the appropriate content for robotic skills training and strongly support content and face validity for this curriculum. Copyright © 2012. Published by Elsevier Inc.
Real-time augmented feedback benefits robotic laparoscopic training.
Judkins, Timothy N; Oleynikov, Dmitry; Stergiou, Nick
2006-01-01
Robotic laparoscopic surgery has revolutionized minimally invasive surgery for treatment of abdominal pathologies. However, current training techniques rely on subjective evaluation. There is a lack of research on the type of tasks that should be used for training. Robotic surgical systems also do not currently have the ability to provide feedback to the surgeon regarding success of performing tasks. We trained medical students on three laparoscopic tasks and provided real-time feedback of performance during training. We found that real-time feedback can benefit training if the feedback provides information that is not available through other means (grip force). Subjects that received grip force feedback applied less force when the feedback was removed. Other forms of feedback (speed and relative phase) did not aid or impede training. Secondly, a relatively short training period (10 trials for each task) significantly improved most objective measures of performance. We also showed that robotic surgical performance can be quantitatively measured and evaluated. Providing grip force feedback can make the surgeon more aware of the forces being applied to delicate tissue during surgery.
Sale, Patrizio; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Cimolin, Veronica; Ancillao, Andrea; Albertini, Giorgio; Galli, Manuela; Stocchi, Fabrizio; Franceschini, Marco
2013-05-24
Over the last years, the introduction of robotic technologies into Parkinson's disease rehabilitation settings has progressed from concept to reality. However, the benefit of robotic training remains elusive. This pilot randomized controlled observer trial is aimed at investigating the feasibility, the effectiveness and the efficacy of new end-effector robot training in people with mild Parkinson's disease. Design. Pilot randomized controlled trial. Robot training was feasible, acceptable, safe, and the participants completed 100% of the prescribed training sessions. A statistically significant improvement in gait index was found in favour of the EG (T0 versus T1). In particular, the statistical analysis of primary outcome (gait speed) using the Friedman test showed statistically significant improvements for the EG (p = 0,0195). The statistical analysis performed by Friedman test of Step length left (p = 0,0195) and right (p = 0,0195) and Stride length left (p = 0,0078) and right (p = 0,0195) showed a significant statistical gain. No statistically significant improvements on the CG were found. Robot training is a feasible and safe form of rehabilitative exercise for cognitively intact people with mild PD. This original approach can contribute to increase a short time lower limb motor recovery in idiopathic PD patients. The focus on the gait recovery is a further characteristic that makes this research relevant to clinical practice. On the whole, the simplicity of treatment, the lack of side effects, and the positive results from patients support the recommendation to extend the use of this treatment. Further investigation regarding the long-time effectiveness of robot training is warranted. ClinicalTrials.gov NCT01668407.
Wiener, Scott; Haddock, Peter; Shichman, Steven; Dorin, Ryan
2015-11-01
To define the time needed by urology residents to attain proficiency in computer-aided robotic surgery to aid in the refinement of a robotic surgery simulation curriculum. We undertook a retrospective review of robotic skills training data acquired during January 2012 to December 2014 from junior (postgraduate year [PGY] 2-3) and senior (PGY4-5) urology residents using the da Vinci Skills Simulator. We determined the number of training sessions attended and the level of proficiency achieved by junior and senior residents in attempting 11 basic or 6 advanced tasks, respectively. Junior residents successfully completed 9.9 ± 1.8 tasks, with 62.5% completing all 11 basic tasks. The maximal cumulative success rate of junior residents completing basic tasks was 89.8%, which was achieved within 7.0 ± 1.5 hours of training. Of senior residents, 75% successfully completed all six advanced tasks. Senior residents attended 6.3 ± 3.5 hours of training during which 5.1 ± 1.6 tasks were completed. The maximal cumulative success rate of senior residents completing advanced tasks was 85.4%. When designing and implementing an effective robotic surgical training curriculum, an allocation of 10 hours of training may be optimal to allow junior and senior residents to achieve an acceptable level of surgical proficiency in basic and advanced robotic surgical skills, respectively. These data help guide the design and scheduling of a residents training curriculum within the time constraints of a resident's workload.
A pilot study of surgical training using a virtual robotic surgery simulator.
Tergas, Ana I; Sheth, Sangini B; Green, Isabel C; Giuntoli, Robert L; Winder, Abigail D; Fader, Amanda N
2013-01-01
Our objectives were to compare the utility of learning a suturing task on the virtual reality da Vinci Skills Simulator versus the da Vinci Surgical System dry laboratory platform and to assess user satisfaction among novice robotic surgeons. Medical trainees were enrolled prospectively; one group trained on the virtual reality simulator, and the other group trained on the da Vinci dry laboratory platform. Trainees received pretesting and post-testing on the dry laboratory platform. Participants then completed an anonymous online user experience and satisfaction survey. We enrolled 20 participants. Mean pretest completion times did not significantly differ between the 2 groups. Training with either platform was associated with a similar decrease in mean time to completion (simulator platform group, 64.9 seconds [P = .04]; dry laboratory platform group, 63.9 seconds [P < .01]). Most participants (58%) preferred the virtual reality platform. The majority found the training "definitely useful" in improving robotic surgical skills (mean, 4.6) and would attend future training sessions (mean, 4.5). Training on the virtual reality robotic simulator or the dry laboratory robotic surgery platform resulted in significant improvements in time to completion and economy of motion for novice robotic surgeons. Although there was a perception that both simulators improved performance, there was a preference for the virtual reality simulator. Benefits unique to the simulator platform include autonomy of use, computerized performance feedback, and ease of setup. These features may facilitate more efficient and sophisticated simulation training above that of the conventional dry laboratory platform, without loss of efficacy.
Srinivasan, Sudha M.; Kaur, Maninderjit; Park, Isabel K.; Gifford, Timothy D.; Marsh, Kerry L.; Bhat, Anjana N.
2015-01-01
We assessed the effects of three interventions, rhythm, robotic, and standard-of-care, on the imitation/praxis, interpersonal synchrony, and overall motor performance of 36 children with Autism Spectrum Disorder (ASD) between 5 and 12 years of age. Children were matched on age, level of functioning, and services received, prior to random assignment to one of the three groups. Training was provided for 8 weeks with 4 sessions provided each week. We assessed generalized changes in motor skills from the pretest to the posttest using a standardized test of motor performance, the Bruininks-Oseretsky Test of Motor Proficiency, 2nd edition (BOT-2). We also assessed training-specific changes in imitation/praxis and interpersonal synchrony during an early and a late session. Consistent with the training activities practiced, the rhythm and robot groups improved on the body coordination composite of the BOT-2, whereas the comparison group improved on the fine manual control composite of the BOT-2. All three groups demonstrated improvements in imitation/praxis. The rhythm and robot groups also showed improved interpersonal synchrony performance from the early to the late session. Overall, socially embedded movement-based contexts are valuable in promoting imitation/praxis, interpersonal synchrony, and motor performance and should be included within the standard-of-care treatment for children with ASD. PMID:26793394
Geroin, Christian; Bortolami, Marta; Saltuari, Leopold; Manganotti, Paolo
2018-01-01
Background Bilateral arm training (BAT) has shown promise in expediting progress toward upper limb recovery in chronic stroke patients, but its neural correlates are poorly understood. Objective To evaluate changes in upper limb function and EEG power after a robot-assisted BAT in chronic stroke patients. Methods In a within-subject design, seven right-handed chronic stroke patients with upper limb paresis received 21 sessions (3 days/week) of the robot-assisted BAT. The outcomes were changes in score on the upper limb section of the Fugl-Meyer assessment (FM), Motricity Index (MI), and Modified Ashworth Scale (MAS) evaluated at the baseline (T0), posttraining (T1), and 1-month follow-up (T2). Event-related desynchronization/synchronization were calculated in the upper alpha and the beta frequency ranges. Results Significant improvement in all outcomes was measured over the course of the study. Changes in FM were significant at T2, and in MAS at T1 and T2. After training, desynchronization on the ipsilesional sensorimotor areas increased during passive and active movement, as compared with T0. Conclusions A repetitive robotic-assisted BAT program may improve upper limb motor function and reduce spasticity in the chronically impaired paretic arm. Effects on spasticity were associated with EEG changes over the ipsilesional sensorimotor network. PMID:29780410
2014-10-01
Award Number:W81XWH-10-1-0981 TITLE:“A Comparison of Robotic, Body Weight-Supported Locomotor Training and Aquatic Therapy in Chronic Motor...three months, three times a week aquatic therapy with similar intensity robotically assisted, body weight supported aerobic treadmill training upon...incomplete spinal cord injury (MISCI). Thirty-seven individuals with chronic MISCI enrolled in this study. We hypothesized aquatic therapy would be
NASA Astrophysics Data System (ADS)
Morita, Yoshifumi; Hirose, Akinori; Uno, Takashi; Uchid, Masaki; Ukai, Hiroyuki; Matsui, Nobuyuki
2007-12-01
In this paper we propose a new rehabilitation training support system for upper limbs. The proposed system enables therapists to quantitatively evaluate the therapeutic effect of upper limb motor function during training, to easily change the load of resistance of training and to easily develop a new training program suitable for the subjects. For this purpose we develop control algorithms of training programs in the 3D force display robot. The 3D force display robot has parallel link mechanism with three motors. The control algorithm simulating sanding training is developed for the 3D force display robot. Moreover the teaching/training function algorithm is developed. It enables the therapists to easily make training trajectory suitable for subject's condition. The effectiveness of the developed control algorithms is verified by experiments.
Hong Kai Yap; Kamaldin, Nazir; Jeong Hoon Lim; Nasrallah, Fatima A; Goh, James Cho Hong; Chen-Hua Yeow
2017-06-01
In this paper, we present the design, fabrication and evaluation of a soft wearable robotic glove, which can be used with functional Magnetic Resonance imaging (fMRI) during the hand rehabilitation and task specific training. The soft wearable robotic glove, called MR-Glove, consists of two major components: a) a set of soft pneumatic actuators and b) a glove. The soft pneumatic actuators, which are made of silicone elastomers, generate bending motion and actuate finger joints upon pressurization. The device is MR-compatible as it contains no ferromagnetic materials and operates pneumatically. Our results show that the device did not cause artifacts to fMRI images during hand rehabilitation and task-specific exercises. This study demonstrated the possibility of using fMRI and MR-compatible soft wearable robotic device to study brain activities and motor performances during hand rehabilitation, and to unravel the functional effects of rehabilitation robotics on brain stimulation.
Automation, robotics, and inflight training for manned Mars missions
NASA Technical Reports Server (NTRS)
Holt, Alan C.
1986-01-01
The automation, robotics, and inflight training requirements of manned Mars missions will be supported by similar capabilities developed for the space station program. Evolutionary space station onboard training facilities will allow the crewmembers to minimize the amount of training received on the ground by providing extensive onboard access to system and experiment malfunction procedures, maintenance procedures, repair procedures, and associated video sequences. Considerable on-the-job training will also be conducted for space station management, mobile remote manipulator operations, proximity operations with the Orbital Maneuvering Vehicle (and later the Orbit Transfer Vehicle), and telerobotics and mobile robots. A similar approach could be used for manned Mars mission training with significant additions such as high fidelity image generation and simulation systems such as holographic projection systems for Mars landing, ascent, and rendezvous training. In addition, a substantial increase in the use of automation and robotics for hazardous and tedious tasks would be expected for Mars mission. Mobile robots may be used to assist in the assembly, test and checkout of the Mars spacecraft, in the handling of nuclear components and hazardous chemical propellent transfer operations, in major spacecraft repair tasks which might be needed (repair of a micrometeroid penetration, for example), in the construction of a Mars base, and for routine maintenance of the base when unmanned.
General surgery training and robotics: Are residents improving their skills?
Finnerty, Brendan M; Afaneh, Cheguevara; Aronova, Anna; Fahey, Thomas J; Zarnegar, Rasa
2016-02-01
While robotic-assisted operations have become more prevalent, many general surgery residencies do not have a formal robotic training curriculum. We sought to ascertain how well current general surgery training permits acquisition of robotic skills by comparing robotic simulation performance across various training levels. Thirty-six participants were categorized by level of surgical training: eight medical students (MS), ten junior residents (JR), ten mid-level residents (MLR), and eight senior residents (SR). Participants performed three simulation tasks on the da Vinci (®) Skills Simulator (MatchBoard, EnergyDissection, SutureSponge). Each task's scores (0-100) and cumulative scores (0-300) were compared between groups. There were no differences in sex, hand dominance, video gaming history, or prior robotic experience between groups; however, SR was the oldest (p < 0.001). The median overall scores did not differ: 188 (84-201) for MS, 183 (91-234) for JR, 197 (153-218) for MLR, and 205 (169-229) for SR (p = 0.14). The median SutureSponge score was highest for SR (61, range 39-81) compared to MS (43, range 26-61), JR (43, range 11-72), and MLR (55, range 36-68) (p = 0.039). However, there were no significant differences in MatchBoard (p = 0.27) or EnergyDissection (p = 0.99) scores between groups. There was a positive correlation between SutureSponge score and number of laparoscopic cases logged (p = 0.005, r(2) = 0.21), but this correlation did not exist for the MatchBoard or EnergyDissection tasks. Lastly, there was no correlation between total lifetime hours of video gaming and overall score (p = 0.89, R(2) = 0.0006). Robotic skillsets acquired during general surgery residency show minimal improvement during the course of training, although laparoscopic experience is correlated with advanced robotic task performance. Changes in residency curricula or pursuit of fellowship training may be warranted for surgeons seeking proficiency.
Training a Network of Electronic Neurons for Control of a Mobile Robot
NASA Astrophysics Data System (ADS)
Vromen, T. G. M.; Steur, E.; Nijmeijer, H.
An adaptive training procedure is developed for a network of electronic neurons, which controls a mobile robot driving around in an unknown environment while avoiding obstacles. The neuronal network controls the angular velocity of the wheels of the robot based on the sensor readings. The nodes in the neuronal network controller are clusters of neurons rather than single neurons. The adaptive training procedure ensures that the input-output behavior of the clusters is identical, even though the constituting neurons are nonidentical and have, in isolation, nonidentical responses to the same input. In particular, we let the neurons interact via a diffusive coupling, and the proposed training procedure modifies the diffusion interaction weights such that the neurons behave synchronously with a predefined response. The working principle of the training procedure is experimentally validated and results of an experiment with a mobile robot that is completely autonomously driving in an unknown environment with obstacles are presented.
Virtual reality-assisted robotic surgery simulation.
Albani, Justin M; Lee, David I
2007-03-01
For more than a decade, advancing computer technologies have allowed incorporation of virtual reality (VR) into surgical training. This has become especially important in training for laparoscopic procedures, which often are complex and leave little room for error. With the advent of robotic surgery and the development and prevalence of a commercial surgical system (da Vinci robot; Intuitive Surgical, Sunnyvale, CA), a valid VR-assisted robotic surgery simulator could minimize the steep learning curve associated with many of these complex procedures and thus enable better outcomes. To date, such simulation does not exist; however, several agencies and corporations are involved in making this dream a reality. We review the history and progress of VR simulation in surgical training, its promising applications in robotic-assisted surgery, and the remaining challenges to implementation.
Virtual reality and robotics for stroke rehabilitation: where do we go from here?
Wade, Eric; Winstein, Carolee J
2011-01-01
Promoting functional recovery after stroke requires collaborative and innovative approaches to neurorehabilitation research. Task-oriented training (TOT) approaches that include challenging, adaptable, and meaningful activities have led to successful outcomes in several large-scale multisite definitive trials. This, along with recent technological advances of virtual reality and robotics, provides a fertile environment for furthering clinical research in neurorehabilitation. Both virtual reality and robotics make use of multimodal sensory interfaces to affect human behavior. In the therapeutic setting, these systems can be used to quantitatively monitor, manipulate, and augment the users' interaction with their environment, with the goal of promoting functional recovery. This article describes recent advances in virtual reality and robotics and the synergy with best clinical practice. Additionally, we describe the promise shown for automated assessments and in-home activity-based interventions. Finally, we propose a broader approach to ensuring that technology-based assessment and intervention complement evidence-based practice and maintain a patient-centered perspective.
Kuznetsov, Alexey N; Rybalko, Natalia V; Daminov, Vadim D; Luft, Andreas R
2013-01-01
Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES) may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES) and robotic tilt-table training (ROBO) against tilt-table training alone (control). A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age 58.3 ± 1.2 years, 4.6 ± 1.2 days after stroke) were assigned to 30 days of ROBO-FES (n = 38), ROBO (n = 35), or control (n = 31) in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC) strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped <10% during robot training. In 52% of controls mean arterial pressure decreased by ≥20%. ROBO-FES increased leg strength by 1.97 ± 0.88 points, ROBO by 1.50 ± 0.85 more than control (1.03 ± 0.61, P < 0.05). CBFV increased in both robotic groups more than in controls (P < 0.05). Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone.
Kuznetsov, Alexey N.; Rybalko, Natalia V.; Daminov, Vadim D.; Luft, Andreas R.
2013-01-01
Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES) may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES) and robotic tilt-table training (ROBO) against tilt-table training alone (control). A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age 58.3 ± 1.2 years, 4.6 ± 1.2 days after stroke) were assigned to 30 days of ROBO-FES (n = 38), ROBO (n = 35), or control (n = 31) in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC) strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped <10% during robot training. In 52% of controls mean arterial pressure decreased by ≥20%. ROBO-FES increased leg strength by 1.97 ± 0.88 points, ROBO by 1.50 ± 0.85 more than control (1.03 ± 0.61, P < 0.05). CBFV increased in both robotic groups more than in controls (P < 0.05). Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone. PMID:23691432
Zhou, Zhihao; Sun, Yao; Wang, Ninghua; Gao, Fan; Wei, Kunlin; Wang, Qining
2016-01-01
In this paper, we aim to investigate the effect of proprioceptive neuromuscular facilitation (PNF)-based rehabilitation for ankle plantar flexors spasticity by using a Robotic Ankle–foot Rehabilitation System (RARS). A modified robot-assisted system was proposed, and seven poststroke patients with hemiplegic spastic ankles participated in a 3-month robotic PNF training. Their impaired sides were used as the experimental group, while their unimpaired sides as the control group. A robotic intervention for the experimental group started from a 2-min passive stretching to warming-up or relaxing the soleus and gastrocnemius muscles and also ended with the same one. Then a PNF training session including 30 trials was activated between them. The rehabilitation trainings were carried out three times a week as an addition to their regular rehabilitation exercise. Passive range of motion, resistance torque, and stiffness were measured in both ankles before and after the interventions. The changes in Achilles tendon length, walking speed, and lower limb function were also evaluated by the same physician or physiotherapist for each participant. Biomechanical measurements before interventions showed significant difference between the experimental group and the control group due to ankle spasticity. For the control group, there was no significant difference in the 3 months with no robotic intervention. But for the experimental group, passive dorsiflexion range of motion increased (p < 0.01), resistance torque under different dorsiflexion angle levels (0°, 10°, and 20°) decreased (p < 0.05, p < 0.001, and p < 0.001, respectively), and quasi-static stiffness under different dorsiflexion angle levels (0°, 10°, and 20°) also decreased (p < 0.01, p < 0.001, and p < 0.001, respectively). Achilles’s tendon length shortened (p < 0.01), while its thickness showed no significant change (p > 0.05). The robotic rehabilitation also improved the muscle strength (p < 0.01) and muscle control performance (p < 0.001). In addition, improvements were observed in clinical and functional measurements, such as Timed Up-and-Go (p < 0.05), normal walking speed (p > 0.05), and fast walking speed (p < 0.05). These results indicated that the PNF-based robotic intervention could significantly alleviate lower limb spasticity and improve the motor function in chronic stroke participant. The robotic system could potentially be used as an effective tool in poststroke rehabilitation training. PMID:27895574
Validation of a novel virtual reality simulator for robotic surgery.
Schreuder, Henk W R; Persson, Jan E U; Wolswijk, Richard G H; Ihse, Ingmar; Schijven, Marlies P; Verheijen, René H M
2014-01-01
With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA) for the use in training of robot-assisted surgery. A comparative cohort study was performed. Participants (n = 42) were divided into three groups according to their robotic experience. To determine construct validity, participants performed three different exercises twice. Performance parameters were measured. To determine face validity, participants filled in a questionnaire after completion of the exercises. Experts outperformed novices in most of the measured parameters. The most discriminative parameters were "time to complete" and "economy of motion" (P < 0.001). The training capacity of the simulator was rated 4.6 ± 0.5 SD on a 5-point Likert scale. The realism of the simulator in general, visual graphics, movements of instruments, interaction with objects, and the depth perception were all rated as being realistic. The simulator is considered to be a very useful training tool for residents and medical specialist starting with robotic surgery. Face and construct validity for the dV-Trainer could be established. The virtual reality simulator is a useful tool for training robotic surgery.
Validation of a Novel Virtual Reality Simulator for Robotic Surgery
Schreuder, Henk W. R.; Persson, Jan E. U.; Wolswijk, Richard G. H.; Ihse, Ingmar; Schijven, Marlies P.; Verheijen, René H. M.
2014-01-01
Objective. With the increase in robotic-assisted laparoscopic surgery there is a concomitant rising demand for training methods. The objective was to establish face and construct validity of a novel virtual reality simulator (dV-Trainer, Mimic Technologies, Seattle, WA) for the use in training of robot-assisted surgery. Methods. A comparative cohort study was performed. Participants (n = 42) were divided into three groups according to their robotic experience. To determine construct validity, participants performed three different exercises twice. Performance parameters were measured. To determine face validity, participants filled in a questionnaire after completion of the exercises. Results. Experts outperformed novices in most of the measured parameters. The most discriminative parameters were “time to complete” and “economy of motion” (P < 0.001). The training capacity of the simulator was rated 4.6 ± 0.5 SD on a 5-point Likert scale. The realism of the simulator in general, visual graphics, movements of instruments, interaction with objects, and the depth perception were all rated as being realistic. The simulator is considered to be a very useful training tool for residents and medical specialist starting with robotic surgery. Conclusions. Face and construct validity for the dV-Trainer could be established. The virtual reality simulator is a useful tool for training robotic surgery. PMID:24600328
2013-01-01
Background Over the last years, the introduction of robotic technologies into Parkinson’s disease rehabilitation settings has progressed from concept to reality. However, the benefit of robotic training remains elusive. This pilot randomized controlled observer trial is aimed at investigating the feasibility, the effectiveness and the efficacy of new end-effector robot training in people with mild Parkinson’s disease. Methods Design. Pilot randomized controlled trial. Setting. Robot assisted gait training (EG) compared to treadmill training (CG). Participants. Twenty cognitively intact participants with mild Parkinson’s disease and gait disturbance. Interventions. The EG underwent a rehabilitation programme of robot assisted walking for 40 minutes, 5 times a week for 4 weeks. The CG received a treadmill training programme for 40 minutes, 5 times a week for 4 weeks. Main outcome measures. The outcome measure of efficacy was recorded by gait analysis laboratory. The assessments were performed at the beginning (T0) and at the end of the treatment (T1). The main outcome was the change in velocity. The feasibility of the intervention was assessed by recording exercise adherence and acceptability by specific test. Results Robot training was feasible, acceptable, safe, and the participants completed 100% of the prescribed training sessions. A statistically significant improvement in gait index was found in favour of the EG (T0 versus T1). In particular, the statistical analysis of primary outcome (gait speed) using the Friedman test showed statistically significant improvements for the EG (p = 0,0195). The statistical analysis performed by Friedman test of Step length left (p = 0,0195) and right (p = 0,0195) and Stride length left (p = 0,0078) and right (p = 0,0195) showed a significant statistical gain. No statistically significant improvements on the CG were found. Conclusions Robot training is a feasible and safe form of rehabilitative exercise for cognitively intact people with mild PD. This original approach can contribute to increase a short time lower limb motor recovery in idiopathic PD patients. The focus on the gait recovery is a further characteristic that makes this research relevant to clinical practice. On the whole, the simplicity of treatment, the lack of side effects, and the positive results from patients support the recommendation to extend the use of this treatment. Further investigation regarding the long-time effectiveness of robot training is warranted. Trial registration ClinicalTrials.gov NCT01668407 PMID:23706025
ERIC Educational Resources Information Center
Tucker, James D.
This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…
`An observational report of intensive robotic and manual gait training in sub-acute stroke
2012-01-01
Background The use of automated electromechanical devices for gait training in neurological patients is increasing, yet the functional outcomes of well-defined training programs using these devices and the characteristics of patients that would most benefit are seldom reported in the literature. In an observational study of functional outcomes, we aimed to provide a benchmark for expected change in gait function in early stroke patients, from an intensive inpatient rehabilitation program including both robotic and manual gait training. Methods We followed 103 sub-acute stroke patients who met the clinical inclusion criteria for Body Weight Supported Robotic Gait Training (BWSRGT). Patients completed an intensive 8-week gait-training program comprising robotic gait training (weeks 0-4) followed by manual gait training (weeks 4-8). A change in clinical function was determined by the following assessments taken at 0, 4 and 8 weeks (baseline, mid-point and end-point respectively): Functional Ambulatory Categories (FAC), 10 m Walking Test (10 MWT), and Tinetti Gait and Balance Scales. Results Over half of the patients made a clinically meaningful improvement on the Tinetti Gait Scale (> 3 points) and Tinetti Balance Scale (> 5 points), while over 80% of the patients increased at least 1 point on the FAC scale (0-5) and improved walking speed by more than 0.2 m/s. Patients responded positively in gait function regardless of variables gender, age, aetiology (hemorrhagic/ischemic), and affected hemisphere. The most robust and significant change was observed for patients in the FAC categories two and three. The therapy was well tolerated and no patients withdrew for factors related to the type or intensity of training. Conclusions Eight-weeks of intensive rehabilitation including robotic and manual gait training was well tolerated by early stroke patients, and was associated with significant gains in function. Patients with mid-level gait dysfunction showed the most robust improvement following robotic training. PMID:22329866
Field studies of safety security rescue technologies through training and response activities
NASA Astrophysics Data System (ADS)
Murphy, Robin R.; Stover, Sam
2006-05-01
This paper describes the field-oriented philosophy of the Institute for Safety Security Rescue Technology (iSSRT) and summarizes the activities and lessons learned during calendar year 2005 of its two centers: the Center for Robot-Assisted Search and Rescue and the NSF Safety Security Rescue industry/university cooperative research center. In 2005, iSSRT participated in four responses (La Conchita, CA, Mudslides, Hurricane Dennis, Hurricane Katrina, Hurricane Wilma) and conducted three field experiments (NJTF-1, Camp Hurricane, Richmond, MO). The lessons learned covered mobility, operator control units, wireless communications, and general reliability. The work has collectively identified six emerging issues for future work. Based on these studies, a 10-hour, 1 continuing education unit credit course on rescue robotics has been created and is available. Rescue robots and sensors are available for loan upon request.
Winder, Joshua S; Juza, Ryan M; Sasaki, Jennifer; Rogers, Ann M; Pauli, Eric M; Haluck, Randy S; Estes, Stephanie J; Lyn-Sue, Jerome R
2016-09-01
The robotic surgical platform is being utilized by a growing number of hospitals across the country, including academic medical centers. Training programs are tasked with teaching their residents how to utilize this technology. To this end, we have developed and implemented a robotic surgical curriculum, and share our initial experience here. Our curriculum was implemented for all General Surgical residents for the academic year 2014-2015. The curriculum consisted of online training, readings, bedside training, console simulation, participating in ten cases as bedside first assistant, and operating at the console. 20 surgical residents were included. Residents were provided the curriculum and notified the department upon completion. Bedside assistance and operative console training were completed in the operating room through a mix of biliary, foregut, and colorectal cases. During the fiscal years of 2014 and 2015, there were 164 and 263 robot-assisted surgeries performed within the General Surgery Department, respectively. All 20 residents completed the online and bedside instruction portions of the curriculum. Of the 20 residents trained, 13/20 (65 %) sat at the Surgeon console during at least one case. Utilizing this curriculum, we have trained and incorporated residents into robot-assisted cases in an efficient manner. A successful curriculum must be based on didactic learning, reading, bedside training, simulation, and training in the operating room. Each program must examine their caseload and resident class to ensure proper exposure to this platform.
Cao, Jinghui; Xie, Sheng Quan; Das, Raj; Zhu, Guo L
2014-12-01
A large number of gait rehabilitation robots, together with a variety of control strategies, have been developed and evaluated during the last decade. Initially, control strategies applied to rehabilitation robots were adapted from those applied to traditional industrial robots. However, these strategies cannot optimise effectiveness of gait rehabilitation. As a result, researchers have been investigating control strategies tailored for the needs of rehabilitation. Among these control strategies, assisted-as-needed (AAN) control is one of the most popular research topics in this field. AAN training strategies have gained the theoretical and practical evidence based backup from motor learning principles and clinical studies. Various approaches to AAN training have been proposed and investigated by research groups all around the world. This article presents a review on control algorithms of gait rehabilitation robots to summarise related knowledge and investigate potential trends of development. There are existing review papers on control strategies of rehabilitation robots. The review by Marchal-Crespo and Reinkensmeyer (2009) had a broad cover of control strategies of all kinds of rehabilitation robots. Hussain et al. (2011) had specifically focused on treadmill gait training robots and covered a limited number of control implementations on them. This review article encompasses more detailed information on control strategies for robot assisted gait rehabilitation, but is not limited to treadmill based training. It also investigates the potential to further develop assist-as-needed gait training based on assessments of patients' ability. In this paper, control strategies are generally divided into the trajectory tracking control and AAN control. The review covers these two basic categories, as well as other control algorithm and technologies derived from them, such as biofeedback control. Assessments on human gait ability are also included to investigate how to further develop implementations based on assist-as-needed concept. For the consideration of effectiveness, clinical studies on robotic gait rehabilitation are reviewed and analysed from the viewpoint of control algorithm. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
Langhorne, Peter; Bernhardt, Julie; Kwakkel, Gert
2011-05-14
Stroke is a common, serious, and disabling global health-care problem, and rehabilitation is a major part of patient care. There is evidence to support rehabilitation in well coordinated multidisciplinary stroke units or through provision of early supported provision of discharge teams. Potentially beneficial treatment options for motor recovery of the arm include constraint-induced movement therapy and robotics. Promising interventions that could be beneficial to improve aspects of gait include fitness training, high-intensity therapy, and repetitive-task training. Repetitive-task training might also improve transfer functions. Occupational therapy can improve activities of daily living; however, information about the clinical effect of various strategies of cognitive rehabilitation and strategies for aphasia and dysarthria is scarce. Several large trials of rehabilitation practice and of novel therapies (eg, stem-cell therapy, repetitive transcranial magnetic stimulation, virtual reality, robotic therapies, and drug augmentation) are underway to inform future practice. Copyright © 2011 Elsevier Ltd. All rights reserved.
Walliczek-Dworschak, U; Mandapathil, M; Förtsch, A; Teymoortash, A; Dworschak, P; Werner, J A; Güldner, C
2017-02-01
The increasing use of minimally invasive techniques such as robotic-assisted devices raises the question of how to acquire robotic surgery skills. The da Vinci Skills Simulator has been demonstrated to be an effective training tool in previous reports. To date, little data are available on how to acquire proficiency through simulator training. We investigated the outcome of a structured training programme for robotic surgical skills by robotic novices. This prospective study was conducted from January to December 2013 using the da Vinci Skills Simulator. Twenty participants, all robotic novices, were enrolled in a 4-week training curriculum. After a brief introduction to the simulator system, three consecutive repetitions of five selected exercises (Match Board 1, 2, 3 and Ring and Rail 1, 2) were performed in a defined order on days 1, 8, 15 and 22. On day 22, one repetition of a previously unpractised more advanced module (Needle Targeting) was also performed. After completion of each study day, the overall performance, time to completion, economy in motion, instrument collisions, excessive instrument force, instruments out of view, master workspace range and number of drops were analysed. Comparing the first and final repetition, overall score and time needed to complete all exercises, economy of motion and instrument collisions were significantly improved in nearly all exercises. Regarding the new exercise, a positive training effect could be demonstrated. While its overall entry score was significantly higher, the time to completion and economy of motion were significantly lower than the scores on the first repetition of the previous 5 exercises. It could be shown that training on the da Vinci Skills Simulator led to an improvement in technical performance of robotic novices. With regard to a new exercise, the training had a positive effect on the technical performance. © 2016 John Wiley & Sons Ltd.
Robot Acquisition of Active Maps Through Teleoperation and Vector Space Analysis
NASA Technical Reports Server (NTRS)
Peters, Richard Alan, II
2003-01-01
The work performed under this contract was in the area of intelligent robotics. The problem being studied was the acquisition of intelligent behaviors by a robot. The method was to acquire action maps that describe tasks as sequences of reflexive behaviors. Action maps (a.k.a. topological maps) are graphs whose nodes represent sensorimotor states and whose edges represent the motor actions that cause the robot to proceed from one state to the next. The maps were acquired by the robot after being teleoperated or otherwise guided by a person through a task several times. During a guided task, the robot records all its sensorimotor signals. The signals from several task trials are partitioned into episodes of static behavior. The corresponding episodes from each trial are averaged to produce a task description as a sequence of characteristic episodes. The sensorimotor states that indicate episode boundaries become the nodes, and the static behaviors, the edges. It was demonstrated that if compound maps are constructed from a set of tasks then the robot can perform new tasks in which it was never explicitly trained.
Robotics in Lower-Limb Rehabilitation after Stroke
2017-01-01
With the increase in the elderly, stroke has become a common disease, often leading to motor dysfunction and even permanent disability. Lower-limb rehabilitation robots can help patients to carry out reasonable and effective training to improve the motor function of paralyzed extremity. In this paper, the developments of lower-limb rehabilitation robots in the past decades are reviewed. Specifically, we provide a classification, a comparison, and a design overview of the driving modes, training paradigm, and control strategy of the lower-limb rehabilitation robots in the reviewed literature. A brief review on the gait detection technology of lower-limb rehabilitation robots is also presented. Finally, we discuss the future directions of the lower-limb rehabilitation robots. PMID:28659660
Robotics in Lower-Limb Rehabilitation after Stroke.
Zhang, Xue; Yue, Zan; Wang, Jing
2017-01-01
With the increase in the elderly, stroke has become a common disease, often leading to motor dysfunction and even permanent disability. Lower-limb rehabilitation robots can help patients to carry out reasonable and effective training to improve the motor function of paralyzed extremity. In this paper, the developments of lower-limb rehabilitation robots in the past decades are reviewed. Specifically, we provide a classification, a comparison, and a design overview of the driving modes, training paradigm, and control strategy of the lower-limb rehabilitation robots in the reviewed literature. A brief review on the gait detection technology of lower-limb rehabilitation robots is also presented. Finally, we discuss the future directions of the lower-limb rehabilitation robots.
Merians, Alma S; Fluet, Gerard G; Qiu, Qinyin; Saleh, Soha; Lafond, Ian; Davidow, Amy; Adamovich, Sergei V
2011-05-16
Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training.
2011-01-01
Background Recovery of upper extremity function is particularly recalcitrant to successful rehabilitation. Robotic-assisted arm training devices integrated with virtual targets or complex virtual reality gaming simulations are being developed to deal with this problem. Neural control mechanisms indicate that reaching and hand-object manipulation are interdependent, suggesting that training on tasks requiring coordinated effort of both the upper arm and hand may be a more effective method for improving recovery of real world function. However, most robotic therapies have focused on training the proximal, rather than distal effectors of the upper extremity. This paper describes the effects of robotically-assisted, integrated upper extremity training. Methods Twelve subjects post-stroke were trained for eight days on four upper extremity gaming simulations using adaptive robots during 2-3 hour sessions. Results The subjects demonstrated improved proximal stability, smoothness and efficiency of the movement path. This was in concert with improvement in the distal kinematic measures of finger individuation and improved speed. Importantly, these changes were accompanied by a robust 16-second decrease in overall time in the Wolf Motor Function Test and a 24-second decrease in the Jebsen Test of Hand Function. Conclusions Complex gaming simulations interfaced with adaptive robots requiring integrated control of shoulder, elbow, forearm, wrist and finger movements appear to have a substantial effect on improving hemiparetic hand function. We believe that the magnitude of the changes and the stability of the patient's function prior to training, along with maintenance of several aspects of the gains demonstrated at retention make a compelling argument for this approach to training. PMID:21575185
Raison, Nicholas; Ahmed, Kamran; Abe, Takashige; Brunckhorst, Oliver; Novara, Giacomo; Buffi, Nicolò; McIlhenny, Craig; van der Poel, Henk; van Hemelrijck, Mieke; Gavazzi, Andrea; Dasgupta, Prokar
2018-05-07
To investigate the effectiveness of motor imagery (MI) for technical skill and non-technical skill (NTS) training in minimally invasive surgery (MIS). A single-blind, parallel-group randomised controlled trial was conducted at the Vattikuti Institute of Robotic Surgery, King's College London. Novice surgeons were recruited by open invitation in 2015. After basic robotic skills training, participants underwent simple randomisation to either MI training or standard training. All participants completed a robotic urethrovesical anastomosis task within a simulated operating room. In addition to the technical task, participants were required to manage three scripted NTS scenarios. Assessment was performed by five blinded expert surgeons and a NTS expert using validated tools for evaluating technical skills [Global Evaluative Assessment of Robotic Skills (GEARS)] and NTS [Non-Technical Skills for Surgeons (NOTSS)]. Quality of MI was assessed using a revised Movement Imagery Questionnaire (MIQ). In all, 33 participants underwent MI training and 29 underwent standard training. Interrater reliability was high, Krippendorff's α = 0.85. After MI training, the mean (sd) GEARS score was significantly higher than after standard training, at 13.1 (3.25) vs 11.4 (2.97) (P = 0.03). There was no difference in mean NOTSS scores, at 25.8 vs 26.4 (P = 0.77). MI training was successful with significantly higher imagery scores than standard training (mean MIQ score 5.1 vs 4.5, P = 0.04). Motor imagery is an effective training tool for improving technical skill in MIS even in novice participants. No beneficial effect for NTS was found. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
Colombo, R; Sterpi, I; Mazzone, A; Delconte, C; Pisano, F
2016-01-01
The purpose of this study was to determine whether a conventional robot-assisted therapy of the upper limb was able to improve proprioception and motor recovery of an individual after stroke who exhibited proprioceptive deficits. After robotic sensorimotor training, significant changes were observed in kinematic performance variables. Two quantitative parameters evaluating position sense improved after training. Range of motion during shoulder and wrist flexion improved, but only wrist flexion remained improved at 3-month follow-up. These preliminary results suggest that intensive robot-aided rehabilitation may play an important role in the recovery of sensory function. However, further studies are required to confirm these data.
Ortiz Oshiro, Elena; Ramos Carrasco, Angel; Moreno Sierra, Jesús; Pardo Martínez, Cristina; Galante Romo, Isabel; Bullón Sopelana, Fernando; Coronado Martín, Pluvio; Mansilla García, Iván; Escudero Mate, María; Vidart Aragón, José A; Silmi Moyano, Angel; Alvarez Fernández-Represa, Jesús
2010-02-01
Da Vinci system (Intuitive Surgical) is a surgical telemanipulator providing many technical advantages over conventional laparoscopic approach (3-D vision, ergonomics, highly precise movements, endowrist instrumentation...) and it is currently applied to several specialties throughout the world since 2000. The first Spanish public hospital incorporating this robotic technology was Hospital Clinico San Carlos (HCSC) in Madrid, in July 2006. We present the multidisciplinary organization and clinical, research and training outcomes of the Robotic Surgery Plan developed in the HCSC. Starting from joint management and joint scrub nurses team, General and Digestive Surgery, Urology and Gynaecology Departments were progressively incorporated into the Robotic Surgery Plan, with several procedures increasing in complexity. A number of intra and extra-hospital teaching and information activities were planned to report on the Robotic Surgery Plan. Between July 2006 and July 2008, 306 patients were operated on: 169 by General Surgery, 107 by Urology and 30 by Gynaecology teams. The outcomes showed feasibility and a short learning curve. The educational plan included residents and staff interested in robotic technology application. The structured and gradual incorporation of robotic surgery throughout the PCR-HCSC has made it easier to learn, to share designed infrastructure, to coordinate information activities and multidisciplinary collaboration. This preliminary experience has shown the efficiency of an adequate organization and motivated team. Copyright 2009 AEC. Published by Elsevier Espana. All rights reserved.
Bortole, Magdo; Venkatakrishnan, Anusha; Zhu, Fangshi; Moreno, Juan C; Francisco, Gerard E; Pons, Jose L; Contreras-Vidal, Jose L
2015-06-17
Stroke significantly affects thousands of individuals annually, leading to considerable physical impairment and functional disability. Gait is one of the most important activities of daily living affected in stroke survivors. Recent technological developments in powered robotics exoskeletons can create powerful adjunctive tools for rehabilitation and potentially accelerate functional recovery. Here, we present the development and evaluation of a novel lower limb robotic exoskeleton, namely H2 (Technaid S.L., Spain), for gait rehabilitation in stroke survivors. H2 has six actuated joints and is designed to allow intensive overground gait training. An assistive gait control algorithm was developed to create a force field along a desired trajectory, only applying torque when patients deviate from the prescribed movement pattern. The device was evaluated in 3 hemiparetic stroke patients across 4 weeks of training per individual (approximately 12 sessions). The study was approved by the Institutional Review Board at the University of Houston. The main objective of this initial pre-clinical study was to evaluate the safety and usability of the exoskeleton. A Likert scale was used to measure patient's perception about the easy of use of the device. Three stroke patients completed the study. The training was well tolerated and no adverse events occurred. Early findings demonstrate that H2 appears to be safe and easy to use in the participants of this study. The overground training environment employed as a means to enhance active patient engagement proved to be challenging and exciting for patients. These results are promising and encourage future rehabilitation training with a larger cohort of patients. The developed exoskeleton enables longitudinal overground training of walking in hemiparetic patients after stroke. The system is robust and safe when applied to assist a stroke patient performing an overground walking task. Such device opens the opportunity to study means to optimize a rehabilitation treatment that can be customized for individuals. This study was registered at ClinicalTrials.gov ( https://clinicaltrials.gov/show/NCT02114450 ).
Tobis, Sławomir; Cylkowska-Nowak, Mirosława; Wieczorowska-Tobis, Katarzyna; Pawlaczyk, Mariola; Suwalska, Aleksandra
2017-01-01
The question arises how recent developments in robotics can contribute to the care for older people. The study is part of the EU-funded ENRICHME project. The aim of the study was to investigate opinions of occupational therapy students (OTS), as future professional caregivers, on the use of robots in care for older people. It included 26 OTS from Poznan University of Medical Sciences. To collect data, the Users' Needs, Requirements, and Abilities Questionnaire (UNRAQ) was developed. OTS perceived the robot as "a useful device" and "an assistant" rather than "a companion" ( p < 0.01). In their opinion, the most important functions of the robot were related to health aspects (emergency alarms, health parameters monitoring, physical activity and memory training, and reminders about medication, drinks, etc.), scored positively by 23-26 OTS. Functions such as mood detection, encouraging to contact with friends, and monitoring of food consumption were accepted by 16-17 OTS. Two statements concerning social functions (accompanying in everyday activities and decreasing the sense of loneliness) were rated positively by less the than half of the participants. A module concerning technology use, including robotics, should constitute an important part of the curricula of both academic and continuous education of OTS.
State-of-the-art robotic devices for ankle rehabilitation: Mechanism and control review.
Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H
2017-12-01
There is an increasing research interest in exploring use of robotic devices for the physical therapy of patients suffering from stroke and spinal cord injuries. Rehabilitation of patients suffering from ankle joint dysfunctions such as drop foot is vital and therefore has called for the development of newer robotic devices. Several robotic orthoses and parallel ankle robots have been developed during the last two decades to augment the conventional ankle physical therapy of patients. A comprehensive review of these robotic ankle rehabilitation devices is presented in this article. Recent developments in the mechanism design, actuation and control are discussed. The study encompasses robotic devices for treadmill and over-ground training as well as platform-based parallel ankle robots. Control strategies for these robotic devices are deliberated in detail with an emphasis on the assist-as-needed training strategies. Experimental evaluations of the mechanism designs and various control strategies of these robotic ankle rehabilitation devices are also presented.
Dominici, Nadia; Keller, Urs; Vallery, Heike; Friedli, Lucia; van den Brand, Rubia; Starkey, Michelle L; Musienko, Pavel; Riener, Robert; Courtine, Grégoire
2012-07-01
Central nervous system (CNS) disorders distinctly impair locomotor pattern generation and balance, but technical limitations prevent independent assessment and rehabilitation of these subfunctions. Here we introduce a versatile robotic interface to evaluate, enable and train pattern generation and balance independently during natural walking behaviors in rats. In evaluation mode, the robotic interface affords detailed assessments of pattern generation and dynamic equilibrium after spinal cord injury (SCI) and stroke. In enabling mode,the robot acts as a propulsive or postural neuroprosthesis that instantly promotes unexpected locomotor capacities including overground walking after complete SCI, stair climbing following partial SCI and precise paw placement shortly after stroke. In training mode, robot-enabled rehabilitation, epidural electrical stimulation and monoamine agonists reestablish weight-supported locomotion, coordinated steering and balance in rats with a paralyzing SCI. This new robotic technology and associated concepts have broad implications for both assessing and restoring motor functions after CNS disorders, both in animals and in humans.
New generation emerging technologies for neurorehabilitation and motor assistance.
Frisoli, Antonio; Solazzi, Massimiliano; Loconsole, Claudio; Barsotti, Michele
2016-12-01
This paper illustrates the application of emerging technologies and human-machine interfaces to the neurorehabilitation and motor assistance fields. The contribution focuses on wearable technologies and in particular on robotic exoskeleton as tools for increasing freedom to move and performing Activities of Daily Living (ADLs). This would result in a deep improvement in quality of life, also in terms of improved function of internal organs and general health status. Furthermore, the integration of these robotic systems with advanced bio-signal driven human-machine interface can increase the degree of participation of patient in robotic training allowing to recognize user's intention and assisting the patient in rehabilitation tasks, thus representing a fundamental aspect to elicit motor learning.
Vaccaro, Christine M; Crisp, Catrina C; Fellner, Angela N; Jackson, Christopher; Kleeman, Steven D; Pavelka, James
2013-01-01
The objective of this study was to compare the effect of virtual reality simulation training plus robotic orientation versus robotic orientation alone on performance of surgical tasks using an inanimate model. Surgical resident physicians were enrolled in this assessor-blinded randomized controlled trial. Residents were randomized to receive either (1) robotic virtual reality simulation training plus standard robotic orientation or (2) standard robotic orientation alone. Performance of surgical tasks was assessed at baseline and after the intervention. Nine of 33 modules from the da Vinci Skills Simulator were chosen. Experts in robotic surgery evaluated each resident's videotaped performance of the inanimate model using the Global Rating Scale (GRS) and Objective Structured Assessment of Technical Skills-modified for robotic-assisted surgery (rOSATS). Nine resident physicians were enrolled in the simulation group and 9 in the control group. As a whole, participants improved their total time, time to incision, and suture time from baseline to repeat testing on the inanimate model (P = 0.001, 0.003, <0.001, respectively). Both groups improved their GRS and rOSATS scores significantly (both P < 0.001); however, the GRS overall pass rate was higher in the simulation group compared with the control group (89% vs 44%, P = 0.066). Standard robotic orientation and/or robotic virtual reality simulation improve surgical skills on an inanimate model, although this may be a function of the initial "practice" on the inanimate model and repeat testing of a known task. However, robotic virtual reality simulation training increases GRS pass rates consistent with improved robotic technical skills learned in a virtual reality environment.
Motor learning characterizes habilitation of children with hemiplegic cerebral palsy.
Krebs, Hermano I; Fasoli, Susan E; Dipietro, Laura; Fragala-Pinkham, Maria; Hughes, Richard; Stein, Joel; Hogan, Neville
2012-09-01
This study tested in children with cerebral palsy (CP) whether motor habilitation resembles motor learning. Twelve children with hemiplegic CP ages 5 to 12 years with moderate to severe motor impairments underwent a 16-session robot-mediated planar therapy program to improve upper limb reach, with a focus on shoulder and elbow movements. Participants were trained to execute point-to-point movements (with robot assistance) with the affected arm and were evaluated (without robot assistance) in trained (point-to-point) and untrained (circle-drawing) conditions. Outcomes were measured at baseline, midpoint, immediately after the program, and 1 month postcompletion. Outcome measures were the Fugl-Meyer (FM), Quality of Upper Extremity Skills Test (QUEST), and Modified Ashworth Scale (MAS) scores; parent questionnaire; and robot-based kinematic metrics. To assess whether learning best characterizes motor habilitation in CP, the authors quantified (a) improvement on trained tasks at completion of training (acquisition) and 1 month following completion (retention) and (b) quantified generalization of improvement to untrained tasks. After robotic intervention, the authors found significant gains in the FM, QUEST, and parent questionnaire. Robot-based evaluations demonstrated significant improvement in trained movements and that improvement was sustained at follow-up. Furthermore, children improved their performance in untrained movements indicating generalization. Motor habilitation in CP exhibits some traits of motor learning. Optimal treatment may not require an extensive repertoire of tasks but rather a select set to promote generalization.
[Implementation of a robot for the preparation of antineoplastic drugs in the Pharmacy Service].
Pacheco Ramos, María de la Paz; Arenaza Peña, Ainhoa Elisa; Santiago Pérez, Alejandro; Bilbao Gómez-Martino, Cristina; Zamora Barrios, María Dolores; Arias Fernández, María Lourdes
2015-05-01
To describe the implementation of a robot for the preparation of antineoplastic drugs in the Pharmacy Service and to be able to analyze the added value to pharmacotherapy. The implementation was carried out in June 2012 at a tertiary level Hospital, taking place in two periods: 1- test period with the installation of the robot, with technical configuration of the equipment and validation of 29 active ingredients and the integration of electronic prescribing software with the robot application (9 months). 2- Usage period (22 months). On the other hand, training was given to pharmacists and nurses. The robot uses image recognition, barcode identification and gravimetric controls for proper operation. These checks provide information about the error ratio in the preparation, with a margin of ± 10%, which after a pilot study was restricted to a range of ±4%. The robot was programmed to recognize bags, infusion pumps, syringes and vials. The added value was assessed for 31 months by identifying preparation's errors. 11,865 preparations were made by the robot, which meant approximately 40% of all antineoplastic prepared from 29 different active ingredients. 1.12% (n=133) of the errors were identified by the robot and therefore didn't reach the patient (negative desviation - 4%). These errors were corrected manually. The implementation of a robot in the preparation of antineoplastic drugs allows to identify errors therefore preventing them to arrive to the patient. This promotes safety and quality of the process, reducing the exposure to cytotoxic drugs from the manipulator. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Kao, Pei-Chun; Lewis, Cara L; Ferris, Daniel P
2010-07-26
To improve design of robotic lower limb exoskeletons for gait rehabilitation, it is critical to identify neural mechanisms that govern locomotor adaptation to robotic assistance. Previously, we demonstrated soleus muscle recruitment decreased by approximately 35% when walking with a pneumatically-powered ankle exoskeleton providing plantar flexor torque under soleus proportional myoelectric control. Since a substantial portion of soleus activation during walking results from the stretch reflex, increased reflex inhibition is one potential mechanism for reducing soleus recruitment when walking with exoskeleton assistance. This is clinically relevant because many neurologically impaired populations have hyperactive stretch reflexes and training to reduce the reflexes could lead to substantial improvements in their motor ability. The purpose of this study was to quantify soleus Hoffmann (H-) reflex responses during powered versus unpowered walking. We tested soleus H-reflex responses in neurologically intact subjects (n=8) that had trained walking with the soleus controlled robotic ankle exoskeleton. Soleus H-reflex was tested at the mid and late stance while subjects walked with the exoskeleton on the treadmill at 1.25 m/s, first without power (first unpowered), then with power (powered), and finally without power again (second unpowered). We also collected joint kinematics and electromyography. When the robotic plantar flexor torque was provided, subjects walked with lower soleus electromyographic (EMG) activation (27-48%) and had concomitant reductions in H-reflex amplitude (12-24%) compared to the first unpowered condition. The H-reflex amplitude in proportion to the background soleus EMG during powered walking was not significantly different from the two unpowered conditions. These findings suggest that the nervous system does not inhibit the soleus H-reflex in response to short-term adaption to exoskeleton assistance. Future studies should determine if the findings also apply to long-term adaption to the exoskeleton.
Galli, M; Cimolin, V; De Pandis, M F; Le Pera, D; Sova, I; Albertini, G; Stocchi, F; Franceschini, M
2016-01-01
The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson's disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD.
Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua
2015-06-01
Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.
NASA Astrophysics Data System (ADS)
Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua
2015-06-01
Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.
A review of training research and virtual reality simulators for the da Vinci surgical system.
Liu, May; Curet, Myriam
2015-01-01
PHENOMENON: Virtual reality simulators are the subject of several recent studies of skills training for robot-assisted surgery. Yet no consensus exists regarding what a core skill set comprises or how to measure skill performance. Defining a core skill set and relevant metrics would help surgical educators evaluate different simulators. This review draws from published research to propose a core technical skill set for using the da Vinci surgeon console. Publications on three commercial simulators were used to evaluate the simulators' content addressing these skills and associated metrics. An analysis of published research suggests that a core technical skill set for operating the surgeon console includes bimanual wristed manipulation, camera control, master clutching to manage hand position, use of third instrument arm, activating energy sources, appropriate depth perception, and awareness of forces applied by instruments. Validity studies of three commercial virtual reality simulators for robot-assisted surgery suggest that all three have comparable content and metrics. However, none have comprehensive content and metrics for all core skills. INSIGHTS: Virtual reality simulation remains a promising tool to support skill training for robot-assisted surgery, yet existing commercial simulator content is inadequate for performing and assessing a comprehensive basic skill set. The results of this evaluation help identify opportunities and challenges that exist for future developments in virtual reality simulation for robot-assisted surgery. Specifically, the inclusion of educational experts in the development cycle alongside clinical and technological experts is recommended.
Beveridge, Briony; Feltracco, Deanna; Struyf, Jillian; Strauss, Emily; Dang, Saniya; Phelan, Shanon; Wright, F Virginia; Gibson, Barbara E
2015-01-01
Innovative robotic technologies hold strong promise for improving walking abilities of children with cerebral palsy (CP), but may create expectations for parents pursuing the "newest thing" in treatment. The aim of this qualitative study was to explore parents' values about walking in relation to their experiences with robotic gait training for their children. Semi-structured interviews were conducted with parents of five ambulatory children with CP participating in a randomized trial investigating robotic gait training effectiveness. Parents valued walking, especially "correct" walking, as a key component of their children's present and future well-being. They continually sought the "next best thing" in therapy and viewed the robotic gait trainer as a potentially revolutionary technology despite mixed experiences. The results can help inform rehabilitation therapists' knowledge of parents' values and perspectives, and guide effective collaborations toward meeting the therapeutic needs of children with CP.
Robotic surgical skill acquisition: What one needs to know?
Sood, Akshay; Jeong, Wooju; Ahlawat, Rajesh; Campbell, Logan; Aggarwal, Shruti; Menon, Mani; Bhandari, Mahendra
2015-01-01
Robotic surgery has been eagerly adopted by patients and surgeons alike in the field of urology, over the last decade. However, there is a lack of standardization in training curricula and accreditation guidelines to ensure surgeon competence and patient safety. Accordingly, in this review, we aim to highlight ‘who’ needs to learn ‘what’ and ‘how’, to become competent in robotic surgery. We demonstrate that both novice and experienced open surgeons require supervision and mentoring during the initial phases of robotic surgery skill acquisition. The experienced open surgeons possess domain knowledge, however, need to acquire technical knowledge under supervision (either in simulated or clinical environment) to successfully transition to robotic surgery, whereas, novice surgeons need to acquire both domain as well as technical knowledge to become competent in robotic surgery. With regard to training curricula, a variety of training programs such as academic fellowships, mini-fellowships, and mentored skill courses exist, and cater to the needs and expectations of postgraduate surgeons adequately. Fellowships provide the most comprehensive training, however, may not be suitable to all surgeon-learners secondary to the long-term time commitment. For these surgeon-learners short-term courses such as the mini-fellowships or mentored skill courses might be more apt. Lastly, with regards to credentialing uniformity in criteria regarding accreditation is lacking but earnest efforts are underway. Currently, accreditation for competence in robotic surgery is institutional specific. PMID:25598593
Robotic surgical skill acquisition: What one needs to know?
Sood, Akshay; Jeong, Wooju; Ahlawat, Rajesh; Campbell, Logan; Aggarwal, Shruti; Menon, Mani; Bhandari, Mahendra
2015-01-01
Robotic surgery has been eagerly adopted by patients and surgeons alike in the field of urology, over the last decade. However, there is a lack of standardization in training curricula and accreditation guidelines to ensure surgeon competence and patient safety. Accordingly, in this review, we aim to highlight 'who' needs to learn 'what' and 'how', to become competent in robotic surgery. We demonstrate that both novice and experienced open surgeons require supervision and mentoring during the initial phases of robotic surgery skill acquisition. The experienced open surgeons possess domain knowledge, however, need to acquire technical knowledge under supervision (either in simulated or clinical environment) to successfully transition to robotic surgery, whereas, novice surgeons need to acquire both domain as well as technical knowledge to become competent in robotic surgery. With regard to training curricula, a variety of training programs such as academic fellowships, mini-fellowships, and mentored skill courses exist, and cater to the needs and expectations of postgraduate surgeons adequately. Fellowships provide the most comprehensive training, however, may not be suitable to all surgeon-learners secondary to the long-term time commitment. For these surgeon-learners short-term courses such as the mini-fellowships or mentored skill courses might be more apt. Lastly, with regards to credentialing uniformity in criteria regarding accreditation is lacking but earnest efforts are underway. Currently, accreditation for competence in robotic surgery is institutional specific.
NASA Technical Reports Server (NTRS)
Smith, Jeffrey D.; Twombly, I. Alexander; Maese, A. Christopher; Cagle, Yvonne; Boyle, Richard
2003-01-01
The International Space Station demonstrates the greatest capabilities of human ingenuity, international cooperation and technology development. The complexity of this space structure is unprecedented; and training astronaut crews to maintain all its systems, as well as perform a multitude of research experiments, requires the most advanced training tools and techniques. Computer simulation and virtual environments are currently used by astronauts to train for robotic arm manipulations and extravehicular activities; but now, with the latest computer technologies and recent successes in areas of medical simulation, the capability exists to train astronauts for more hands-on research tasks using immersive virtual environments. We have developed a new technology, the Virtual Glovebox (VGX), for simulation of experimental tasks that astronauts will perform aboard the Space Station. The VGX may also be used by crew support teams for design of experiments, testing equipment integration capability and optimizing the procedures astronauts will use. This is done through the 3D, desk-top sized, reach-in virtual environment that can simulate the microgravity environment in space. Additional features of the VGX allow for networking multiple users over the internet and operation of tele-robotic devices through an intuitive user interface. Although the system was developed for astronaut training and assisting support crews, Earth-bound applications, many emphasizing homeland security, have also been identified. Examples include training experts to handle hazardous biological and/or chemical agents in a safe simulation, operation of tele-robotic systems for assessing and diffusing threats such as bombs, and providing remote medical assistance to field personnel through a collaborative virtual environment. Thus, the emerging VGX simulation technology, while developed for space- based applications, can serve a dual use facilitating homeland security here on Earth.
An over-view of robot assisted surgery curricula and the status of their validation.
Fisher, Rebecca A; Dasgupta, Prokar; Mottrie, Alex; Volpe, Alessandro; Khan, Mohammed S; Challacombe, Ben; Ahmed, Kamran
2015-01-01
Robotic surgery is a rapidly expanding field. Thus far training for robotic techniques has been unstructured and the requirements are variable across various regions. Several projects are currently underway to develop a robotic surgery curriculum and are in various stages of validation. We aimed to outline the structures of available curricula, their process of development, validation status and current utilization. We undertook a literature review of papers including the MeSH terms "Robotics" and "Education". When we had an overview of curricula in development, we searched recent conference abstracts to gain up to date information. The main curricula are the FRS, the FSRS, the Canadian BSTC and the ERUS initiative. They are in various stages of validation and offer a mixture of theoretical and practical training, using both physical and simulated models. Whilst the FSRS is based on tasks on the RoSS virtual reality simulator, FRS and BSTC are designed for use on simulators and the robot itself. The ERUS curricula benefits from a combination of dry lab, wet lab and virtual reality components, which may allow skills to be more transferable to the OR as tasks are completed in several formats. Finally, the ERUS curricula includes the OR modular training programme as table assistant and console surgeon. Curricula are a crucial step in global standardisation of training and certification of surgeons for robotic surgical procedures. Many curricula are in early stages of development and more work is needed in development and validation of these programmes before training can be standardised. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-01
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,749] Fanuc Robotics America... period, Fanuc Robotics America neither imported articles like or directly competitive with the robotic.... Furthermore, the Department surveyed Fanuc Robotics America's major declining customers regarding purchases of...
Robotic Arms. A Contribution to the Curriculum. An Occasional Paper.
ERIC Educational Resources Information Center
Arnold, W. F.; Carpenter, C. J.
This report examines ways of providing technician training in the operating principles of robotic devices. The terms "robotics" and "robotic arms" are first defined. Some background information on the principal features of robotic arms is given, including their geometric arrangement, type of actuator used, control method, and…
KineAssist: design and development of a robotic overground gait and balance therapy device.
Patton, James; Brown, David A; Peshkin, Michael; Santos-Munné, Julio J; Makhlin, Alex; Lewis, Ela; Colgate, Edward J; Schwandt, Doug
2008-01-01
Balance and mobility training consists of activities that carry a high risk for falling. The purpose of this article is to describe a novel robotic system for allowing challenging, yet safe, balance and mobility training in persons at high risk for falls. With no initial preconceptions of what device we would build, a user-needs analysis led us to focus on increasing the level of challenge to a patient's ability to maintain balance during gait training and also on maintaining direct involvement of a physical therapist (rather than attempting robotic replacement). The KineAssist is a robotic device for gait and balance training that has emerged from a unique design process of a start-up product of a small company and a team of therapists, engineers, mechanical design experts, and rehabilitation scientists. The KineAssist provides partial body weight support and postural control on the torso; allows many axes of motion of the trunk and pelvis; leaves the patient's legs accessible to a physical therapist's manipulation during walking; follows a patient's walking motions overground in forward, rotation, and sidestepping directions; and catches an individual who loses balance and begins to fall. Design and development of the KineAssist proceeded more rapidly in the context of a small company than would have been possible in most institutional research contexts. A prototype KineAssist has been constructed and has received US Food and Drug Administration (FDA) classification and institutional review board clearance for initial human studies. The acceptance of KineAssist will ultimately depend on improved patient outcomes, the use of this new tool by therapists, the ease of use of the system, and the recognition of the unique value it brings to therapeutic recovery.
Yun, Sang-Seok; Choi, JongSuk; Park, Sung-Kee; Bong, Gui-Young; Yoo, HeeJeong
2017-07-01
We designed a robot system that assisted in behavioral intervention programs of children with autism spectrum disorder (ASD). The eight-session intervention program was based on the discrete trial teaching protocol and focused on two basic social skills: eye contact and facial emotion recognition. The robotic interactions occurred in four modules: training element query, recognition of human activity, coping-mode selection, and follow-up action. Children with ASD who were between 4 and 7 years old and who had verbal IQ ≥ 60 were recruited and randomly assigned to the treatment group (TG, n = 8, 5.75 ± 0.89 years) or control group (CG, n = 7; 6.32 ± 1.23 years). The therapeutic robot facilitated the treatment intervention in the TG, and the human assistant facilitated the treatment intervention in the CG. The intervention procedures were identical in both groups. The primary outcome measures included parent-completed questionnaires, the Autism Diagnostic Observation Schedule (ADOS), and frequency of eye contact, which was measured with the partial interval recording method. After completing treatment, the eye contact percentages were significantly increased in both groups. For facial emotion recognition, the percentages of correct answers were increased in similar patterns in both groups compared to baseline (P > 0.05), with no difference between the TG and CG (P > 0.05). The subjects' ability to play, general behavioral and emotional symptoms were significantly diminished after treatment (p < 0.05). These results showed that the robot-facilitated and human-facilitated behavioral interventions had similar positive effects on eye contact and facial emotion recognition, which suggested that robots are useful mediators of social skills training for children with ASD. Autism Res 2017,. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. Autism Res 2017, 10: 1306-1323. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.
Robot-Assisted Training Early After Cardiac Surgery.
Schoenrath, Felix; Markendorf, Susanne; Brauchlin, Andreas E; Seifert, Burkhardt; Wilhelm, Markus J; Czerny, Martin; Riener, Robert; Falk, Volkmar; Schmied, Christian M
2015-07-01
To assess feasibility and safety of a robot-assisted gait therapy with the Lokomat® system in patients early after open heart surgery. Within days after open heart surgery 10 patients were subjected to postoperative Lokomat® training (Intervention group, IG) whereas 20 patients served as controls undergoing standard postoperative physiotherapy (Control group, CG). All patients underwent six-minute walk test and evaluation of the muscular strength of the lower limbs by measuring quadriceps peak force. The primary safety end-point was freedom from any device-related wound healing disturbance. Patients underwent clinical follow-up after one month. Both training methods resulted in an improvement of walking distance (IG [median, interquartile range, p-value]: +119 m, 70-201 m, p = 0.005; CG: 105 m, 57-152.5m, p < 0.001) and quadriceps peak force (IG left: +5 N, 3.8 7 N, p = 0.005; IG right: +3.5 N, 1.5-8.8 N, p = 0.011; CG left: +5.5 N, 4-9 N, p < 0.001; CG right: +6 N, 4.3-9.8 N, p < 0.001) in all participants. Results with robot-assisted training were comparable to early postoperative standard in hospital training (median changes in walking distance in percent, p = 0.81; median changes in quadriceps peak force in percent, left: p = 0.97, right p = 0.61). No deep sternal wound infection or any adverse event occurred in the robot-assisted training group. Robot-assisted gait therapy with the Lokomat® system is feasible and safe in patients early after median sternotomy. Results with robot-assisted training were comparable to standard in hospital training. An adapted and combined aerobic and resistance training intervention with augmented feedback may result in benefits in walking distance and lower limb muscle strength (ClinicalTrials.gov number, NCT 02146196). © 2015 Wiley Periodicals, Inc.
Geigle, Paula R; Frye, Sara Kate; Perreault, John; Scott, William H; Gorman, Peter H
2013-03-01
A 41-year-old man with a history of C6 American Spinal Injury Association (ASIA) Impairment Scale (AIS) C spinal cord injury (SCI), enrolled in an Institutional Review Board (IRB)-approved, robotic-assisted body weight-supported treadmill training (BWSTT), and aquatic exercise research protocol developed asymptomatic autonomic dysreflexia (AD) during training. Little information is available regarding the relationship of robotic-assisted BWSTT and AD. After successfully completing 36 sessions of aquatic exercise, he reported exertional fatigue during his 10th Lokomat intervention and exhibited asymptomatic or silent AD during this and the three subsequent BWSTT sessions. Standard facilitators of AD were assessed and no obvious irritant identified other than the actual physical exertion and positioning required during robotic-assisted BWSTT. Increased awareness of potential silent AD presenting during robotic assisted BWSTT training for individuals with motor incomplete SCI is required as in this case AD clinical signs were not concurrent with occurrence. Frequent vital sign assessment before, during, and at conclusion of each BWSTT session is strongly recommended.
SEFRE: Semiexoskeleton Rehabilitation System.
Chonnaparamutt, Winai; Supsi, Witsarut
2016-01-01
SEFRE (Shoulder-Elbow-Forearm Robotics Economic) rehabilitation system is presented in this paper. SEFRE Rehab System is composed of a robotic manipulator and an exoskeleton, so-called Forearm Supportive Mechanism (FSM). The controller of the system is developed as the Master PC consisting of five modules, that is, Intelligent Control (IC), Patient Communication (PC), Training with Game (TG), Progress Monitoring (PM), and Patient Supervision (PS). These modules support a patient to exercise with SEFRE in six modes, that is, Passive, Passive Stretching, Passive Guiding, Initiating Active, Active Assisted, and Active Resisted. To validate the advantages of the system, the preclinical trial was carried out at a national rehabilitation center. Here, the implement of the system and the preclinical results are presented as the verifications of SEFRE.
Szold, Amir; Bergamaschi, Roberto; Broeders, Ivo; Dankelman, Jenny; Forgione, Antonello; Langø, Thomas; Melzer, Andreas; Mintz, Yoav; Morales-Conde, Salvador; Rhodes, Michael; Satava, Richard; Tang, Chung-Ngai; Vilallonga, Ramon
2015-02-01
Following an extensive literature search and a consensus conference with subject matter experts the following conclusions can be drawn: 1. Robotic surgery is still at its infancy, and there is a great potential in sophisticated electromechanical systems to perform complex surgical tasks when these systems evolve. 2. To date, in the vast majority of clinical settings, there is little or no advantage in using robotic systems in general surgery in terms of clinical outcome. Dedicated parameters should be addressed, and high quality research should focus on quality of care instead of routine parameters, where a clear advantage is not to be expected. 3. Preliminary data demonstrates that robotic system have a clinical benefit in performing complex procedures in confined spaces, especially in those that are located in unfavorable anatomical locations. 4. There is a severe lack of high quality data on robotic surgery, and there is a great need for rigorously controlled, unbiased clinical trials. These trials should be urged to address the cost-effectiveness issues as well. 5. Specific areas of research should include complex hepatobiliary surgery, surgery for gastric and esophageal cancer, revisional surgery in bariatric and upper GI surgery, surgery for large adrenal masses, and rectal surgery. All these fields show some potential for a true benefit of using current robotic systems. 6. Robotic surgery requires a specific set of skills, and needs to be trained using a dedicated, structured training program that addresses the specific knowledge, safety issues and skills essential to perform this type of surgery safely and with good outcomes. It is the responsibility of the corresponding professional organizations, not the industry, to define the training and credentialing of robotic basic skills and specific procedures. 7. Due to the special economic environment in which robotic surgery is currently employed special care should be taken in the decision making process when deciding on the purchase, use and training of robotic systems in general surgery. 8. Professional organizations in the sub-specialties of general surgery should review these statements and issue detailed, specialty-specific guidelines on the use of specific robotic surgery procedures in addition to outlining the advanced robotic surgery training required to safely perform such procedures.
Lefeber, Nina; Swinnen, Eva; Kerckhofs, Eric
2017-10-01
The integration of sufficient cardiovascular stress into robot-assisted gait (RAG) training could combine the benefits of both RAG and aerobic training. The aim was to summarize literature data on the immediate effects of RAG compared to walking without robot-assistance on metabolic-, cardiorespiratory- and fatigue-related parameters. PubMed and Web of Science were searched for eligible articles till February 2016. Means, SDs and significance values were extracted. Effect sizes were calculated. Fourteen studies were included, concerning 155 participants (85 healthy subjects, 39 stroke and 31 spinal cord injury patients), 9 robots (2 end-effectors, 1 treadmill-based and 6 wearable exoskeletons), and 7 outcome parameters (mostly oxygen consumption and heart rate). Overall, metabolic and cardiorespiratory parameters were lower during RAG compared to walking without robot-assistance (moderate to large effect sizes). In healthy subjects, when no body-weight support (BWS) was provided, RAG with an end-effector device was more energy demanding than walking overground (p > .05, large effect sizes). Generally, results suggest that RAG is less energy-consuming and cardiorespiratory stressful than walking without robot-assistance, but results depend on factors such as robot type, walking speed, BWS and effort. Additional research is needed to draw firm conclusions. Implications for Rehabilitation Awareness of the energy consumption and cardiorespiratory load of robot-assisted gait (RAG) training is important in the rehabilitation of (neurological) patients with impaired cardiorespiratory fitness and patients who are at risk of cardiovascular diseases. On the other hand, the integration of sufficient cardiometabolic stress in RAG training could combine the effects of both RAG and aerobic training. Energy consumption and cardiorespiratory load during walking with robot-assistance seems to depend on factors such as robot type, walking speed, body-weight support or amount of effort. These parameters could be adjusted in RAG rehabilitation to make RAG more or less energy-consuming and cardiorespiratory stressful. Overall, short duration exoskeleton walking seems less energy-consuming and cardiorespiratory stressful than walking without robot-assistance. This might implicate that the exercise intensity is safe for (neurological) patients at risk of cardiovascular diseases. How this changes in extended walking time is unclear.
Adamovich, Sergei; Fluet, Gerard G.; Merians, Alma S.; Mathai, Abraham; Qiu, Qinyin
2010-01-01
Current neuroscience has identified several constructs to increase the effectiveness of upper extremity rehabilitation. One is the use of progressive, skill acquisition-oriented training. Another approach emphasizes the use of bilateral activities. Building on these principles, this paper describes the design and feasibility testing of a robotic / virtual environment system designed to train the arm of persons who have had strokes. The system provides a variety of assistance modes, scalable workspaces and hand-robot interfaces allowing persons with strokes to train multiple joints in three dimensions. The simulations utilize assistance algorithms that adjust task difficulty both online and offline in relation to subject performance. Several distinctive haptic effects have been incorporated into the simulations. An adaptive master-slave relationship between the unimpaired and impaired arm encourages active movement of the subject's hemiparetic arm during a bimanual task. Adaptive anti-gravity support and damping stabilize the arm during virtual reaching and placement tasks. An adaptive virtual spring provides assistance to complete the movement if the subject is unable to complete the task in time. Finally, haptically rendered virtual objects help to shape the movement trajectory during a virtual placement task. A proof of concept study demonstrated this system to be safe, feasible and worthy of further study. PMID:19666345
Kim, Soo Jeong; Lee, Hye Jin; Hwang, Seung Won; Pyo, Hannah; Yang, Sung Phil; Lim, Mun-Hee; Park, Gyu Lee
2016-01-01
Objective To identify the clinical characteristics of proper robot-assisted gait training group using exoskeletal locomotor devices in non-ambulatory subacute stroke patients. Methods A total of 38 stroke patients were enrolled in a 4-week robotic training protocol (2 sessions/day, 5 times/week). All subjects were evaluated for their general characteristics, Functional Ambulatory Classification (FAC), Fugl-Meyer Scale (FMS), Berg Balance Scale (BBS), Modified Rankin Scale (MRS), Modified Barthel Index (MBI), and Mini-Mental Status Examination (MMSE) at 0, 2, and 4 weeks. Statistical analysis were performed to determine significant clinical characteristics for improvement of gait function after robot-assisted gait training. Results Paired t-test showed that all functional parameters except MMSE were improved significantly (p<0.05). The duration of disease and baseline BBS score were significantly (p<0.05) correlated with FAC score in multiple regression models. Receiver operating characteristic (ROC) curve showed that a baseline BBS score of '9' was a cutoff value (AUC, 0.966; sensitivity, 91%–100%; specificity, 85%). By repeated-measures ANOVA, the differences in improved walking ability according to time were significant between group of patients who had baseline BBS score of '9' and those who did not have baseline BBS score of '9' Conclusion Our results showed that a baseline BBS score above '9' and a short duration of disease were highly correlated with improved walking ability after robot-assisted gait training. Therefore, baseline BBS and duration of disease should be considered clinically for gaining walking ability in robot-assisted training group. PMID:27152266
Hovgaard, Lisette Hvid; Andersen, Steven Arild Wuyts; Konge, Lars; Dalsgaard, Torur; Larsen, Christian Rifbjerg
2018-03-30
The use of robotic surgery for minimally invasive procedures has increased considerably over the last decade. Robotic surgery has potential advantages compared to laparoscopic surgery but also requires new skills. Using virtual reality (VR) simulation to facilitate the acquisition of these new skills could potentially benefit training of robotic surgical skills and also be a crucial step in developing a robotic surgical training curriculum. The study's objective was to establish validity evidence for a simulation-based test for procedural competency for the vaginal cuff closure procedure that can be used in a future simulation-based, mastery learning training curriculum. Eleven novice gynaecological surgeons without prior robotic experience and 11 experienced gynaecological robotic surgeons (> 30 robotic procedures) were recruited. After familiarization with the VR simulator, participants completed the module 'Guided Vaginal Cuff Closure' six times. Validity evidence was investigated for 18 preselected simulator metrics. The internal consistency was assessed using Cronbach's alpha and a composite score was calculated based on metrics with significant discriminative ability between the two groups. Finally, a pass/fail standard was established using the contrasting groups' method. The experienced surgeons significantly outperformed the novice surgeons on 6 of the 18 metrics. The internal consistency was 0.58 (Cronbach's alpha). The experienced surgeons' mean composite score for all six repetitions were significantly better than the novice surgeons' (76.1 vs. 63.0, respectively, p < 0.001). A pass/fail standard of 75/100 was established. Four novice surgeons passed this standard (false positives) and three experienced surgeons failed (false negatives). Our study has gathered validity evidence for a simulation-based test for procedural robotic surgical competency in the vaginal cuff closure procedure and established a credible pass/fail standard for future proficiency-based training.
Review of control strategies for robotic movement training after neurologic injury.
Marchal-Crespo, Laura; Reinkensmeyer, David J
2009-06-16
There is increasing interest in using robotic devices to assist in movement training following neurologic injuries such as stroke and spinal cord injury. This paper reviews control strategies for robotic therapy devices. Several categories of strategies have been proposed, including, assistive, challenge-based, haptic simulation, and coaching. The greatest amount of work has been done on developing assistive strategies, and thus the majority of this review summarizes techniques for implementing assistive strategies, including impedance-, counterbalance-, and EMG- based controllers, as well as adaptive controllers that modify control parameters based on ongoing participant performance. Clinical evidence regarding the relative effectiveness of different types of robotic therapy controllers is limited, but there is initial evidence that some control strategies are more effective than others. It is also now apparent there may be mechanisms by which some robotic control approaches might actually decrease the recovery possible with comparable, non-robotic forms of training. In future research, there is a need for head-to-head comparison of control algorithms in randomized, controlled clinical trials, and for improved models of human motor recovery to provide a more rational framework for designing robotic therapy control strategies.
Model of a training program in robotic surgery and its initial results.
Madureira, Fernando Athayde Veloso; Varela, José Luís Souza; Madureira, Delta; D'Almeida, Luis Alfredo Vieira; Madureira, Fábio Athayde Veloso; Duarte, Alexandre Miranda; Vaz, Otávio Pires; Ramos, José Reinan
2017-01-01
to describe the implementation of a training program in robotic surgery and to point the General Surgery procedures that can be performed with advantages using the robotic platform. we conducted a retrospective analysis of data collected prospectively from the robotic surgery group in General and Colo-Retal Surgery at the Samaritan Hospital (Rio de Janeiro, Brazil), from October 2012 to December 2015. We describe the training stages and particularities. two hundred and ninety three robotic operations were performed in general surgery: 108 procedures for morbid obesity, 59 colorectal surgeries, 55 procedures in the esophago-gastric transition area, 16 cholecystectomies, 27 abdominal wall hernioplasties, 13 inguinal hernioplasties, two gastrectomies with D2 lymphadenectomy, one vagotomy, two diaphragmatic hernioplasties, four liver surgeries, two adrenalectomies, two splenectomies, one pancreatectomy and one bilio-digestive anastomosis. The complication rate was 2.4%, with no major complications. the robotic surgery program of the Samaritan Hospital was safely implemented and with initial results better than the ones described in the current literature. There seems to be benefits in using the robotic platform in super-obese patients, re-operations of obesity surgery and hiatus hernias, giant and paraesophageal hiatus hernias, ventral hernias with multiple defects and rectal resections.
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, Laura; Reinkensmeyer, David J
2009-01-01
There is increasing interest in using robotic devices to assist in movement training following neurologic injuries such as stroke and spinal cord injury. This paper reviews control strategies for robotic therapy devices. Several categories of strategies have been proposed, including, assistive, challenge-based, haptic simulation, and coaching. The greatest amount of work has been done on developing assistive strategies, and thus the majority of this review summarizes techniques for implementing assistive strategies, including impedance-, counterbalance-, and EMG- based controllers, as well as adaptive controllers that modify control parameters based on ongoing participant performance. Clinical evidence regarding the relative effectiveness of different types of robotic therapy controllers is limited, but there is initial evidence that some control strategies are more effective than others. It is also now apparent there may be mechanisms by which some robotic control approaches might actually decrease the recovery possible with comparable, non-robotic forms of training. In future research, there is a need for head-to-head comparison of control algorithms in randomized, controlled clinical trials, and for improved models of human motor recovery to provide a more rational framework for designing robotic therapy control strategies. PMID:19531254
Noninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
NASA Astrophysics Data System (ADS)
Meng, Jianjun; Zhang, Shuying; Bekyo, Angeliki; Olsoe, Jaron; Baxter, Bryan; He, Bin
2016-12-01
Brain-computer interface (BCI) technologies aim to provide a bridge between the human brain and external devices. Prior research using non-invasive BCI to control virtual objects, such as computer cursors and virtual helicopters, and real-world objects, such as wheelchairs and quadcopters, has demonstrated the promise of BCI technologies. However, controlling a robotic arm to complete reach-and-grasp tasks efficiently using non-invasive BCI has yet to be shown. In this study, we found that a group of 13 human subjects could willingly modulate brain activity to control a robotic arm with high accuracy for performing tasks requiring multiple degrees of freedom by combination of two sequential low dimensional controls. Subjects were able to effectively control reaching of the robotic arm through modulation of their brain rhythms within the span of only a few training sessions and maintained the ability to control the robotic arm over multiple months. Our results demonstrate the viability of human operation of prosthetic limbs using non-invasive BCI technology.
Scano, A; Chiavenna, A; Caimmi, M; Malosio, M; Tosatti, L M; Molteni, F
2017-07-01
Robot-assisted training is a widely used technique to promote motor re-learning on post-stroke patients that suffer from motor impairment. While it is commonly accepted that robot-based therapies are potentially helpful, strong insights about their efficacy are still lacking. The motor re-learning process may act on muscular synergies, which are groups of co-activating muscles that, being controlled as a synergic group, allow simplifying the problem of motor control. In fact, by coordinating a reduced amount of neural signals, complex motor patterns can be elicited. This paper aims at analyzing the effects of robot assistance during 3D-reaching movements in the framework of muscular synergies. 5 healthy people and 3 neurological patients performed free and robot-assisted reaching movements at 2 different speeds (slow and quasi-physiological). EMG recordings were used to extract muscular synergies. Results indicate that the interaction with the robot very slightly alters healthy people patterns but, on the contrary, it may promote the emergency of physiological-like synergies on neurological patients.
Łyp, Marek; Stanisławska, Iwona; Witek, Bożena; Olszewska-Żaczek, Ewelina; Czarny-Działak, Małgorzata; Kaczor, Ryszard
2018-02-13
This study deals with the use of a robot-assisted body-weight-supported treadmill training in multiple sclerosis (MS) patients with gait dysfunction. Twenty MS patients (10 men and 10 women) of the mean of 46.3 ± 8.5 years were assigned to a six-week-long training period with the use of robot-assisted treadmill training of increasing intensity of the Lokomat type. The outcome measure consisted of the difference in motion-dependent torque of lower extremity joint muscles after training compared with baseline before training. We found that the training uniformly and significantly augmented the torque of both extensors and flexors of the hip and knee joints. The muscle power in the lower limbs of SM patients was improved, leading to corrective changes of disordered walking movements, which enabled the patients to walk with less effort and less assistance of care givers. The torque augmentation could have its role in affecting the function of the lower extremity muscle groups during walking. The results of this pilot study suggest that the robot-assisted body-weight-supported treadmill training may be a potential adjunct measure in the rehabilitation paradigm of 'gait reeducation' in peripheral neuropathies.
POINTER: Portable Intelligent Trainer for External Robotics
NASA Technical Reports Server (NTRS)
Kuiper, Hilbert; Rikken, Patrick J.
1994-01-01
Intelligent tutoring systems (ITS's) play an increasing role in training and education of people with different levels of skill and knowledge. As compared to conventional computer based training (CBT) an ITS provides more tailored instruction by trying to mimic the teaching behavior of a human instructor as much as possible and is therefore much more flexible. This paper starts with an introduction to ITS's, followed by the description of an ITS for training of an (astronaut) operator in monitoring and controlling robotic arm procedures. The robotic arm will be used for exchange of equipment between a space station and a space plane involving critical and accurate movements of the robotic arm. The ITS for this application, called Pointer, is developed by TNO Physics and Electronics Laboratory and is based upon an existing ITS that includes procedural training. Pointer has been developed on a workstation whereas the target platform was a portable computer. Therefore, a lot of attention had to be paid to scaling effects and keeping up with user friendliness of the much smaller user interface. Although the learning domain was the control of a robotic arm, it is clear that use of intelligent training technologies on a portable computer has many other applications (payload operations, operation control rooms, etc.). Training can occur at any time and place in an attractive and cost effective way.
Raison, Nicholas; Ahmed, Kamran; Fossati, Nicola; Buffi, Nicolò; Mottrie, Alexandre; Dasgupta, Prokar; Van Der Poel, Henk
2017-05-01
To develop benchmark scores of competency for use within a competency based virtual reality (VR) robotic training curriculum. This longitudinal, observational study analysed results from nine European Association of Urology hands-on-training courses in VR simulation. In all, 223 participants ranging from novice to expert robotic surgeons completed 1565 exercises. Competency was set at 75% of the mean expert score. Benchmark scores for all general performance metrics generated by the simulator were calculated. Assessment exercises were selected by expert consensus and through learning-curve analysis. Three basic skill and two advanced skill exercises were identified. Benchmark scores based on expert performance offered viable targets for novice and intermediate trainees in robotic surgery. Novice participants met the competency standards for most basic skill exercises; however, advanced exercises were significantly more challenging. Intermediate participants performed better across the seven metrics but still did not achieve the benchmark standard in the more difficult exercises. Benchmark scores derived from expert performances offer relevant and challenging scores for trainees to achieve during VR simulation training. Objective feedback allows both participants and trainers to monitor educational progress and ensures that training remains effective. Furthermore, the well-defined goals set through benchmarking offer clear targets for trainees and enable training to move to a more efficient competency based curriculum. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Safety, efficiency and learning curves in robotic surgery: a human factors analysis.
Catchpole, Ken; Perkins, Colby; Bresee, Catherine; Solnik, M Jonathon; Sherman, Benjamin; Fritch, John; Gross, Bruno; Jagannathan, Samantha; Hakami-Majd, Niv; Avenido, Raymund; Anger, Jennifer T
2016-09-01
Expense, efficiency of use, learning curves, workflow integration and an increased prevalence of serious incidents can all be barriers to adoption. We explored an observational approach and initial diagnostics to enhance total system performance in robotic surgery. Eighty-nine robotic surgical cases were observed in multiple operating rooms using two different surgical robots (the S and Si), across several specialties (Urology, Gynecology, and Cardiac Surgery). The main measures were operative duration and rate of flow disruptions-described as 'deviations from the natural progression of an operation thereby potentially compromising safety or efficiency.' Contextual parameters collected were surgeon experience level and training, type of surgery, the model of robot and patient factors. Observations were conducted across four operative phases (operating room pre-incision; robot docking; main surgical intervention; post-console). A mean of 9.62 flow disruptions per hour (95 % CI 8.78-10.46) were predominantly caused by coordination, communication, equipment and training problems. Operative duration and flow disruption rate varied with surgeon experience (p = 0.039; p < 0.001, respectively), training cases (p = 0.012; p = 0.007) and surgical type (both p < 0.001). Flow disruption rates in some phases were also sensitive to the robot model and patient characteristics. Flow disruption rate is sensitive to system context and generates improvement diagnostics. Complex surgical robotic equipment increases opportunities for technological failures, increases communication requirements for the whole team, and can reduce the ability to maintain vision in the operative field. These data suggest specific opportunities to reduce the training costs and the learning curve.
Hand Rehabilitation Robotics on Poststroke Motor Recovery
2017-01-01
The recovery of hand function is one of the most challenging topics in stroke rehabilitation. Although the robot-assisted therapy has got some good results in the latest decades, the development of hand rehabilitation robotics is left behind. Existing reviews of hand rehabilitation robotics focus either on the mechanical design on designers' view or on the training paradigms on the clinicians' view, while these two parts are interconnected and both important for designers and clinicians. In this review, we explore the current literature surrounding hand rehabilitation robots, to help designers make better choices among varied components and thus promoting the application of hand rehabilitation robots. An overview of hand rehabilitation robotics is provided in this paper firstly, to give a general view of the relationship between subjects, rehabilitation theories, hand rehabilitation robots, and its evaluation. Secondly, the state of the art hand rehabilitation robotics is introduced in detail according to the classification of the hardware system and the training paradigm. As a result, the discussion gives available arguments behind the classification and comprehensive overview of hand rehabilitation robotics. PMID:29230081
Saleh, Soha; Fluet, Gerard; Qiu, Qinyin; Merians, Alma; Adamovich, Sergei V.; Tunik, Eugene
2017-01-01
Several approaches to rehabilitation of the hand following a stroke have emerged over the last two decades. These treatments, including repetitive task practice (RTP), robotically assisted rehabilitation and virtual rehabilitation activities, produce improvements in hand function but have yet to reinstate function to pre-stroke levels—which likely depends on developing the therapies to impact cortical reorganization in a manner that favors or supports recovery. Understanding cortical reorganization that underlies the above interventions is therefore critical to inform how such therapies can be utilized and improved and is the focus of the current investigation. Specifically, we compare neural reorganization elicited in stroke patients participating in two interventions: a hybrid of robot-assisted virtual reality (RAVR) rehabilitation training and a program of RTP training. Ten chronic stroke subjects participated in eight 3-h sessions of RAVR therapy. Another group of nine stroke subjects participated in eight sessions of matched RTP therapy. Functional magnetic resonance imaging (fMRI) data were acquired during paretic hand movement, before and after training. We compared the difference between groups and sessions (before and after training) in terms of BOLD intensity, laterality index of activation in sensorimotor areas, and the effective connectivity between ipsilesional motor cortex (iMC), contralesional motor cortex, ipsilesional primary somatosensory cortex (iS1), ipsilesional ventral premotor area (iPMv), and ipsilesional supplementary motor area. Last, we analyzed the relationship between changes in fMRI data and functional improvement measured by the Jebsen Taylor Hand Function Test (JTHFT), in an attempt to identify how neurophysiological changes are related to motor improvement. Subjects in both groups demonstrated motor recovery after training, but fMRI data revealed RAVR-specific changes in neural reorganization patterns. First, BOLD signal in multiple regions of interest was reduced and re-lateralized to the ipsilesional side. Second, these changes correlated with improvement in JTHFT scores. Our findings suggest that RAVR training may lead to different neurophysiological changes when compared with traditional therapy. This effect may be attributed to the influence that augmented visual and haptic feedback during RAVR training exerts over higher-order somatosensory and visuomotor areas. PMID:28928708
Motor Learning Characterizes Habilitation of Children With Hemiplegic Cerebral Palsy
Krebs, Hermano I.; Fasoli, Susan E.; Dipietro, Laura; Fragala-Pinkham, Maria; Hughes, Richard; Stein, Joel; Hogan, Neville
2015-01-01
Background This study tested in children with cerebral palsy (CP) whether motor habilitation resembles motor learning. Methods Twelve children with hemiplegic CP ages 5 to 12 years with moderate to severe motor impairments underwent a 16-session robot-mediated planar therapy program to improve upper limb reach, with a focus on shoulder and elbow movements. Participants were trained to execute point-to-point movements (with robot assistance) with the affected arm and were evaluated (without robot assistance) in trained (point-to-point) and untrained (circle-drawing) conditions. Outcomes were measured at baseline, midpoint, immediately after the program, and 1 month postcompletion. Outcome measures were the Fugl-Meyer (FM), Quality of Upper Extremity Skills Test (QUEST), and Modified Ashworth Scale (MAS) scores; parent questionnaire; and robot-based kinematic metrics. To assess whether learning best characterizes motor habilitation in CP, the authors quantified (a) improvement on trained tasks at completion of training (acquisition) and 1 month following completion (retention) and (b) quantified generalization of improvement to untrained tasks. Results After robotic intervention, the authors found significant gains in the FM, QUEST, and parent questionnaire. Robot-based evaluations demonstrated significant improvement in trained movements and that improvement was sustained at follow-up. Furthermore, children improved their performance in untrained movements indicating generalization. Conclusions Motor habilitation in CP exhibits some traits of motor learning. Optimal treatment may not require an extensive repertoire of tasks but rather a select set to promote generalization. PMID:22331211
[Robotics in general surgery: personal experience, critical analysis and prospectives].
Fracastoro, Gerolamo; Borzellino, Giuseppe; Castelli, Annalisa; Fiorini, Paolo
2005-01-01
Today mini invasive surgery has the chance to be enhanced with sophisticated informative systems (Computer Assisted Surgery, CAS) like robotics, tele-mentoring and tele-presence. ZEUS and da Vinci, present in more than 120 Centres in the world, have been used in many fields of surgery and have been tested in some general surgical procedures. Since the end of 2003, we have performed 70 experimental procedures and 24 operations of general surgery with ZEUS robotic system, after having properly trained 3 surgeons and the operating room staff. Apart from the robot set-up, the mean operative time of the robotic operations was similar to the laparoscopic ones; no complications due to robotic technique occurred. The Authors report benefits and disadvantages related to robots' utilization, problems still to be solved and the possibility to make use of them with tele-surgery, training and virtual surgery.
Srinivasan, Sudha M.; Eigsti, Inge-Marie; Neelly, Linda; Bhat, Anjana N.
2016-01-01
We compared the effects of 8-weeks of rhythm and robotic interventions with those of a comparison, standard-of-care intervention, on the spontaneous and responsive social attention patterns of school-age children with Autism Spectrum Disorder. Attention patterns were examined within a standardized pretest/posttest measure of joint attention (JA) and a training-specific social attention measure during early, mid, and late training sessions. The rhythm and comparison groups demonstrated improvements in JA. Social attention was greater in the rhythm followed by the robot and lastly the comparison group. The robot and comparison groups spent maximum time fixating on the robot and objects, respectively. Across sessions, the robot group decreased attention to the robot and increased attention to elsewhere. Overall, rhythmic movement contexts afford sustained social monitoring in children with autism. PMID:27453721
Caimmi, Marco; Chiavenna, Andrea; Scano, Alessandro; Gasperini, Giulio; Giovanzana, Chiara; Molinari Tosatti, Lorenzo; Molteni, Franco
2017-06-01
Robotic rehabilitation is promising to promote function in stroke patients. The assist as needed training paradigm has shown to stimulate neuroplasticity but often cannot be used because stroke patients are too impaired to actively control the robot against gravity. To verify whether a rehabilitation intervention based on robot fully assisted reaching against gravity (RCH) and hand-to-mouth (HTM) can promote upper-limb function in chronic stroke. Cohort study. Chronic stroke outpatients referring to the robotic rehabilitation lab of a rehabilitation centre. Ten chronic stroke patients with mild to moderate upper-limb hemiparesis. Patients underwent 12 sessions (3 per week) of robotic treatment using an end-effector robot Every session consisted of 20 minutes each of RCH and HtM; movements were fully assisted, but patients were asked to try to actively participate. The Fugl-Meyer Assessment (FMA) was the primary outcome measure; Medical Research Council and Modified Ashworth Scale were the secondary outcome measures. All patients, but one, show functional improvements (FMA section A-D, mean increment 7.2±3.9 points, P<0.008). This preliminary study shows that a robotic intervention based on functional movements, fully assisted, can be effective in promoting function in chronic stroke patients. These results are promising considering the short time of the intervention (1 month) and the time from the stroke event, which was large (27±20 months). A larger study, comprehensive of objective instrumental measures, is necessary to confirm the results. This intervention could be extended even to subacute stroke and other neurological disorders.
Cylkowska-Nowak, Mirosława; Pawlaczyk, Mariola
2017-01-01
Background The question arises how recent developments in robotics can contribute to the care for older people. The study is part of the EU-funded ENRICHME project. Objectives of Study The aim of the study was to investigate opinions of occupational therapy students (OTS), as future professional caregivers, on the use of robots in care for older people. Methods It included 26 OTS from Poznan University of Medical Sciences. To collect data, the Users' Needs, Requirements, and Abilities Questionnaire (UNRAQ) was developed. Findings OTS perceived the robot as “a useful device” and “an assistant” rather than “a companion” (p < 0.01). In their opinion, the most important functions of the robot were related to health aspects (emergency alarms, health parameters monitoring, physical activity and memory training, and reminders about medication, drinks, etc.), scored positively by 23–26 OTS. Functions such as mood detection, encouraging to contact with friends, and monitoring of food consumption were accepted by 16-17 OTS. Two statements concerning social functions (accompanying in everyday activities and decreasing the sense of loneliness) were rated positively by less the than half of the participants. Limitations and Recommendations for Further Research A module concerning technology use, including robotics, should constitute an important part of the curricula of both academic and continuous education of OTS. PMID:29097983
Robotic Mirror Therapy System for Functional Recovery of Hemiplegic Arms.
Beom, Jaewon; Koh, Sukgyu; Nam, Hyung Seok; Kim, Wonshik; Kim, Yoonjae; Seo, Han Gil; Oh, Byung-Mo; Chung, Sun Gun; Kim, Sungwan
2016-08-15
Mirror therapy has been performed as effective occupational therapy in a clinical setting for functional recovery of a hemiplegic arm after stroke. It is conducted by eliciting an illusion through use of a mirror as if the hemiplegic arm is moving in real-time while moving the healthy arm. It can facilitate brain neuroplasticity through activation of the sensorimotor cortex. However, conventional mirror therapy has a critical limitation in that the hemiplegic arm is not actually moving. Thus, we developed a real-time 2-axis mirror robot system as a simple add-on module for conventional mirror therapy using a closed feedback mechanism, which enables real-time movement of the hemiplegic arm. We used 3 Attitude and Heading Reference System sensors, 2 brushless DC motors for elbow and wrist joints, and exoskeletal frames. In a feasibility study on 6 healthy subjects, robotic mirror therapy was safe and feasible. We further selected tasks useful for activities of daily living training through feedback from rehabilitation doctors. A chronic stroke patient showed improvement in the Fugl-Meyer assessment scale and elbow flexor spasticity after a 2-week application of the mirror robot system. Robotic mirror therapy may enhance proprioceptive input to the sensory cortex, which is considered to be important in neuroplasticity and functional recovery of hemiplegic arms. The mirror robot system presented herein can be easily developed and utilized effectively to advance occupational therapy.
Improving the transparency of a rehabilitation robot by exploiting the cyclic behaviour of walking.
van Dijk, W; van der Kooij, H; Koopman, B; van Asseldonk, E H F; van der Kooij, H
2013-06-01
To promote active participation of neurological patients during robotic gait training, controllers, such as "assist as needed" or "cooperative control", are suggested. Apart from providing support, these controllers also require that the robot should be capable of resembling natural, unsupported, walking. This means that they should have a transparent mode, where the interaction forces between the human and the robot are minimal. Traditional feedback-control algorithms do not exploit the cyclic nature of walking to improve the transparency of the robot. The purpose of this study was to improve the transparent mode of robotic devices, by developing two controllers that use the rhythmic behavior of gait. Both controllers use adaptive frequency oscillators and kernel-based non-linear filters. Kernelbased non-linear filters can be used to estimate signals and their time derivatives, as a function of the gait phase. The first controller learns the motor angle, associated with a certain joint angle pattern, and acts as a feed-forward controller to improve the torque tracking (including the zero-torque mode). The second controller learns the state of the mechanical system and compensates for the dynamical effects (e.g. the acceleration of robot masses). Both controllers have been tested separately and in combination on a small subject population. Using the feedforward controller resulted in an improved torque tracking of at least 52 percent at the hip joint, and 61 percent at the knee joint. When both controllers were active simultaneously, the interaction power between the robot and the human leg was reduced by at least 40 percent at the thigh, and 43 percent at the shank. These results indicate that: if a robotic task is cyclic, the torque tracking and transparency can be improved by exploiting the predictions of adaptive frequency oscillator and kernel-based nonlinear filters.
Door detection in images based on learning by components
NASA Astrophysics Data System (ADS)
Cicirelli, Grazia; D'Orazio, Tiziana; Ancona, Nicola
2001-10-01
In this paper we present a vision-based technique for detecting targets of the environment which has to be reached by an autonomous mobile robot during its navigational task. The targets the robot has to reach are the doors of our office building. Color and shape information are used as identifying features for detecting principal components of the door. In fact in images the door can appear of different dimensions depending on the attitude of the robot with respect to the door, therefore detection of the door is performed by detecting its most significant components in the image. Positive and negative examples, in form of image patterns, are manually selected from real images for training two neural classifiers in order to recognize the single components. Each classifier has been realized by a feed-forward neural network with one hidden layer and sigmoid activation function. Moreover for selecting negative examples, relevant for the problem at hand, a bootstrap technique has been used during the training process. Finally the detecting system has been applied to several test real images for evaluating its performance.
Song, Rong; Tong, Kai-Yu; Hu, Xiaoling; Li, Le; Sun, Rui
2013-09-01
This study designed an arm-eye coordination test to investigate the effectiveness of the robot-aided rehabilitation for persons after stroke. Six chronic poststroke subjects were recruited to attend a 20-session robot-aided rehabilitation training of elbow joint. Before and after the training program, subjects were asked to perform voluntary movements of elbow flection and extension by following sinusoidal trajectories at different velocities with visual feedback on their joint positions. The elbow angle and the electromyographic signal of biceps and triceps as well as clinical scores were evaluated together with the parameters. Performance was objectively quantified by root mean square error (RMSE), root mean square jerk (RMSJ), range of motion (ROM), and co-contraction index (CI). After 20 sessions, RMSE and ROM improved significantly in both the affected and the unaffected side based on two-way ANOVA (P < 0.05). There was significant lower RMSJ in the affected side at higher velocities (P < 0.05). There was significant negative correlation between average RMSE with different tracking velocities and Fugl-Meyer shoulder-elbow score (P < 0.05). There was also significant negative correlation between average RMSE and average ROM (P < 0.05), and moderate nonsignificant negative correlation with RMSJ, and CI. The characterization of velocity-dependent deficiencies, monitoring of training-induced improvement, and the correlation between quantitative parameters and clinical scales could enable the exploration of effects of different types of treatment and design progress-based training method to accelerate the processes of recovery.
Galli, Manuela; Cimolin, Veronica; De Pandis, Maria Francesca; Le Pera, Domenica; Sova, Ivan; Albertini, Giorgio; Stocchi, Fabrizio; Franceschini, Marco
2016-01-01
Summary The purpose of this study was to quantitatively compare the effects, on walking performance, of end-effector robotic rehabilitation locomotor training versus intensive training with a treadmill in Parkinson’s disease (PD). Fifty patients with PD were randomly divided into two groups: 25 were assigned to the robot-assisted therapy group (RG) and 25 to the intensive treadmill therapy group (IG). They were evaluated with clinical examination and 3D quantitative gait analysis [gait profile score (GPS) and its constituent gait variable scores (GVSs) were calculated from gait analysis data] at the beginning (T0) and at the end (T1) of the treatment. In the RG no differences were found in the GPS, but there were significant improvements in some GVSs (Pelvic Obl and Hip Ab-Add). The IG showed no statistically significant changes in either GPS or GVSs. The end-effector robotic rehabilitation locomotor training improved gait kinematics and seems to be effective for rehabilitation in patients with mild PD. PMID:27678210
How to get the best from robotic thoracic surgery.
Ricciardi, Sara; Zirafa, Carmelina Cristina; Davini, Federico; Melfi, Franca
2018-04-01
The application of Robotic technology in thoracic surgery has become widespread in the last decades. Thanks to its advanced features, the robotic system allows to perform a broad range of complex operations safely and in a comfortable way, with valuable advantages related to low invasiveness. Regarding lung tumours, several studies have shown the benefits of robotic surgery including lower blood loss and improved lymph node removal when compared with other minimally invasive techniques. Moreover, the robotic instruments allow to reach deep and narrow spaces permitting safe and precise removal of tumours located in remote areas, such as retrosternal and posterior mediastinal spaces with outstanding postoperative and oncological results. One controversial finding about the application of robotic system is its high capital and running costs. For this reason, a limited number of centres worldwide are able to employ this groundbreaking technology and there are limited possibilities for the trainees to acquire the necessary skills in robotic surgery. Therefore, a training programme based on three steps of learning, associated with a solid surgical background and a consistent operating activity, are required to obtain effective results. Putting this highest technological innovation in the hand of expert surgeons we can assure safe and effective procedures getting the best from robotic thoracic surgery.
Objective assessment in residency-based training for transoral robotic surgery.
Curry, Martin; Malpani, Anand; Li, Ryan; Tantillo, Thomas; Jog, Amod; Blanco, Ray; Ha, Patrick K; Califano, Joseph; Kumar, Rajesh; Richmon, Jeremy
2012-10-01
To develop a robotic surgery training regimen integrating objective skill assessment for otolaryngology and head and neck surgery trainees consisting of training modules of increasing complexity leading up to procedure-specific training. In particular, we investigated applications of such a training approach for surgical extirpation of oropharyngeal tumors via a transoral approach using the da Vinci robotic system. Prospective blinded data collection and objective evaluation (Objective Structured Assessment of Technical Skills [OSATS]) of three distinct phases using the da Vinci robotic surgical system in an academic university medical engineering/computer science laboratory setting. Between September 2010 and July 2011, eight otolaryngology-head and neck surgery residents and four staff experts from an academic hospital participated in three distinct phases of robotic surgery training involving 1) robotic platform operational skills, 2) set up of the patient side system, and 3) a complete ex vivo surgical extirpation of an oropharyngeal tumor located in the base of tongue. Trainees performed multiple (four) approximately equally spaced training sessions in each stage of the training. In addition to trainees, baseline performance data were obtained for the experts. Each surgical stage was documented with motion and event data captured from the application programming interfaces of the da Vinci system, as well as separate video cameras as appropriate. All data were assessed using automated skill measures of task efficiency and correlated with structured assessment (OSATS and similar Likert scale) from three experts to assess expert and trainee differences and compute automated and expert assessed learning curves. Our data show that such training results in an improved didactic robotic knowledge base and improved clinical efficiency with respect to the set up and console manipulation. Experts (e.g., average OSATS, 25; standard deviation [SD], 3.1; module 1, suturing) and trainees (average OSATS, 15.9; SD, 3.9; week 1) are well separated at the beginning of the training, and the separation reduces significantly (expert average OSATS, 27.6; SD, 2.7; trainee average OSATS, 24.2; SD, 6.8; module 3) at the conclusion of the training. Learning curves in each of the three stages show diminishing differences between the experts and trainees, which is also consistent with expert assessment. Subjective assessment by experts verified the clinical utility of the module 3 surgical environment, and a survey of trainees consistently rated the curriculum as very useful in progression to human operating room assistance. Structured curricular robotic surgery training with objective assessment promises to reduce the overhead for mentors, allow detailed assessment of human-machine interface skills, and create customized training models for individualized training. This preliminary study verifies the utility of such training in improving human-machine operations skills (module 1), and operating room and surgical skills (modules 2 and 3). In contrast to current coarse measures of total operating time and subjective assessment of error for short mass training sessions, these methods may allow individual tasks to be removed from the trainee regimen when skill levels are within the standard deviation of the experts for these tasks, which can greatly enhance overall efficiency of the training regimen and allow time for additional and more complex training to be incorporated in the same time frame. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
NASA Technical Reports Server (NTRS)
Clancey, William J.
2004-01-01
This viewgraph presentation provides an overview of past and possible future applications for artifical intelligence (AI) in astronaut instruction and training. AI systems have been used in training simulation for the Hubble Space Telescope repair, the International Space Station, and operations simulation for the Mars Exploration Rovers. In the future, robots such as may work as partners with astronauts on missions such as planetary exploration and extravehicular activities.
Straudi, Sofia; Manfredini, Fabio; Lamberti, Nicola; Zamboni, Paolo; Bernardi, Francesco; Marchetti, Giovanna; Pinton, Paolo; Bonora, Massimo; Secchiero, Paola; Tisato, Veronica; Volpato, Stefano; Basaglia, Nino
2017-02-27
Gait and mobility impairments affect the quality of life (QoL) of patients with progressive multiple sclerosis (MS). Robot-assisted gait training (RAGT) is an effective rehabilitative treatment but evidence of its superiority compared to other options is lacking. Furthermore, the response to rehabilitation is multidimensional, person-specific and possibly involves functional reorganization processes. The aims of this study are: (1) to test the effectiveness on gait speed, mobility, balance, fatigue and QoL of RAGT compared to conventional therapy (CT) in progressive MS and (2) to explore changes of clinical and circulating biomarkers of neural plasticity. This will be a parallel-group, randomized controlled trial design with the assessor blinded to the group allocation of participants. Ninety-eight (49 per arm) progressive MS patients (EDSS scale 6-7) will be randomly assigned to receive twelve 2-h training sessions over a 4-week period (three sessions/week) of either: (1) RAGT intervention on a robotic-driven gait orthosis (Lokomat, Hocoma, Switzerland). The training parameters (torque of the knee and hip drives, treadmill speed, body weight support) are set during the first session and progressively adjusted during training progression or (2) individual conventional physiotherapy focusing on over-ground walking training performed with the habitual walking device. The same assessors will perform outcome measurements at four time points: baseline (before the first intervention session); intermediate (after six training sessions); end of treatment (after the completion of 12 sessions); and follow-up (after 3 months from the end of the training program). The primary outcome is gait speed, assessed by the Timed 25-Foot Walk Test. We will also assess walking endurance, balance, depression, fatigue and QoL as well as instrumental laboratory markers (muscle metabolism, cerebral venous hemodynamics, cortical activation) and circulating laboratory markers (rare circulating cell populations pro and anti-inflammatory cytokines/chemokines, growth factors, neurotrophic factors, coagulation factors, other plasma proteins suggested by transcriptomic analysis and metabolic parameters). The RAGT training is expected to improve mobility compared to the active control intervention in progressive MS. Unique to this study is the analysis of various potential markers of plasticity in relation with clinical outcomes. ClinicalTrials.gov, identifier: NCT02421731 . Registered on 19 January 2015 (retrospectively registered).
Crowdsourcing: a valid alternative to expert evaluation of robotic surgery skills.
Polin, Michael R; Siddiqui, Nazema Y; Comstock, Bryan A; Hesham, Helai; Brown, Casey; Lendvay, Thomas S; Martino, Martin A
2016-11-01
Robotic-assisted gynecologic surgery is common, but requires unique training. A validated assessment tool for evaluating trainees' robotic surgery skills is Robotic-Objective Structured Assessments of Technical Skills. We sought to assess whether crowdsourcing can be used as an alternative to expert surgical evaluators in scoring Robotic-Objective Structured Assessments of Technical Skills. The Robotic Training Network produced the Robotic-Objective Structured Assessments of Technical Skills, which evaluate trainees across 5 dry lab robotic surgical drills. Robotic-Objective Structured Assessments of Technical Skills were previously validated in a study of 105 participants, where dry lab surgical drills were recorded, de-identified, and scored by 3 expert surgeons using the Robotic-Objective Structured Assessments of Technical Skills checklist. Our methods-comparison study uses these previously obtained recordings and expert surgeon scores. Mean scores per participant from each drill were separated into quartiles. Crowdworkers were trained and calibrated on Robotic-Objective Structured Assessments of Technical Skills scoring using a representative recording of a skilled and novice surgeon. Following this, 3 recordings from each scoring quartile for each drill were randomly selected. Crowdworkers evaluated the randomly selected recordings using Robotic-Objective Structured Assessments of Technical Skills. Linear mixed effects models were used to derive mean crowdsourced ratings for each drill. Pearson correlation coefficients were calculated to assess the correlation between crowdsourced and expert surgeons' ratings. In all, 448 crowdworkers reviewed videos from 60 dry lab drills, and completed a total of 2517 Robotic-Objective Structured Assessments of Technical Skills assessments within 16 hours. Crowdsourced Robotic-Objective Structured Assessments of Technical Skills ratings were highly correlated with expert surgeon ratings across each of the 5 dry lab drills (r ranging from 0.75-0.91). Crowdsourced assessments of recorded dry lab surgical drills using a validated assessment tool are a rapid and suitable alternative to expert surgeon evaluation. Copyright © 2016 Elsevier Inc. All rights reserved.
Kumazaki, Hirokazu; Warren, Zachary; Corbett, Blythe A.; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Higashida, Haruhiro; Yuhi, Teruko; Ikeda, Takashi; Ishiguro, Hiroshi; Kikuchi, Mitsuru
2017-01-01
The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18–25 years) with autism spectrum disorder (ASD) were randomized to participate either in a mock job interview training with our android robot system (n = 7) or a self-paced review of materials about job-interviewing skills (n = 8). Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning. PMID:28955254
Kumazaki, Hirokazu; Warren, Zachary; Corbett, Blythe A; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Higashida, Haruhiro; Yuhi, Teruko; Ikeda, Takashi; Ishiguro, Hiroshi; Kikuchi, Mitsuru
2017-01-01
The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18-25 years) with autism spectrum disorder (ASD) were randomized to participate either in a mock job interview training with our android robot system ( n = 7) or a self-paced review of materials about job-interviewing skills ( n = 8). Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning.
Tele-surgery simulation with a patient organ model for robotic surgery training.
Suzuki, S; Suzuki, N; Hattori, A; Hayashibe, M; Konishi, K; Kakeji, Y; Hashizume, M
2005-12-01
Robotic systems are increasingly being incorporated into general laparoscopic and thoracoscopic surgery to perform procedures such as cholecystectomy and prostatectomy. Robotic assisted surgery allows the surgeon to conduct minimally invasive surgery with increased accuracy and with potential benefits for patients. However, current robotic systems have their limitations. These include the narrow operative field of view, which can make instrument manipulation difficult. Current robotic applications are also tailored to specific surgical procedures. For these reasons, there is an increasing demand on surgeons to master the skills of instrument manipulation and their surgical application within a controlled environment. This study describes the development of a surgical simulator for training and mastering procedures performed with the da Vinci surgical system. The development of a tele-surgery simulator and the construction of a training center are also described, which will enable surgeons to simulate surgery from or in remote places, to collaborate over long distances, and for off-site expert assistance. Copyright 2005 John Wiley & Sons, Ltd.
Evolutionary programming-based univector field navigation method for past mobile robots.
Kim, Y J; Kim, J H; Kwon, D S
2001-01-01
Most of navigation techniques with obstacle avoidance do not consider the robot orientation at the target position. These techniques deal with the robot position only and are independent of its orientation and velocity. To solve these problems this paper proposes a novel univector field method for fast mobile robot navigation which introduces a normalized two dimensional vector field. The method provides fast moving robots with the desired posture at the target position and obstacle avoidance. To obtain the sub-optimal vector field, a function approximator is used and trained by evolutionary programming. Two kinds of vector fields are trained, one for the final posture acquisition and the other for obstacle avoidance. Computer simulations and real experiments are carried out for a fast moving mobile robot to demonstrate the effectiveness of the proposed scheme.
Serendipitous Offline Learning in a Neuromorphic Robot.
Stewart, Terrence C; Kleinhans, Ashley; Mundy, Andrew; Conradt, Jörg
2016-01-01
We demonstrate a hybrid neuromorphic learning paradigm that learns complex sensorimotor mappings based on a small set of hard-coded reflex behaviors. A mobile robot is first controlled by a basic set of reflexive hand-designed behaviors. All sensor data is provided via a spike-based silicon retina camera (eDVS), and all control is implemented via spiking neurons simulated on neuromorphic hardware (SpiNNaker). Given this control system, the robot is capable of simple obstacle avoidance and random exploration. To train the robot to perform more complex tasks, we observe the robot and find instances where the robot accidentally performs the desired action. Data recorded from the robot during these times is then used to update the neural control system, increasing the likelihood of the robot performing that task in the future, given a similar sensor state. As an example application of this general-purpose method of training, we demonstrate the robot learning to respond to novel sensory stimuli (a mirror) by turning right if it is present at an intersection, and otherwise turning left. In general, this system can learn arbitrary relations between sensory input and motor behavior.
Straudi, S; Benedetti, M G; Venturini, E; Manca, M; Foti, C; Basaglia, N
2013-01-01
Gait disorders are common in multiple sclerosis (MS) and lead to a progressive reduction of function and quality of life. Test the effects of robot-assisted gait rehabilitation in MS subjects through a pilot randomized-controlled study. We enrolled MS subjects with Expanded Disability Status Scale scores within 4.5-6.5. The experimental group received 12 robot-assisted gait training sessions over 6 weeks. The control group received the same amount of conventional physiotherapy. Outcomes measures were both biomechanical assessment of gait, including kinematics and spatio-temporal parameters, and clinical test of walking endurance (six-minute walk test) and mobility (Up and Go Test). 16 subjects (n = 8 experimental group, n = 8 control group) were included in the final analysis. At baseline the two groups were similar in all variables, except for step length. Data showed walking endurance, as well as spatio-temporal gait parameters improvements after robot-assisted gait training. Pelvic antiversion and reduced hip extension during terminal stance ameliorated after aforementioned intervention. Robot-assisted gait training seems to be effective in increasing walking competency in MS subjects. Moreover, it could be helpful in restoring the kinematic of the hip and pelvis.
Supporting the joint warfighter by development, training, and fielding of man-portable UGVs
NASA Astrophysics Data System (ADS)
Ebert, Kenneth A.; Stratton, Benjamin V.
2005-05-01
The Robotic Systems Pool (RSP), sponsored by the Joint Robotics Program (JRP), is an inventory of small robotic systems, payloads, and components intended to expedite the development and integration of technology into effective, supportable, fielded robotic assets. The RSP loans systems to multiple users including the military, first-responders, research organizations, and academia. These users provide feedback in their specific domain, accelerating research and development improvements of robotic systems, which in turn allow the joint warfighter to benefit from such changes more quickly than from traditional acquisition cycles. Over the past year, RSP assets have been used extensively for pre-deployment operator and field training of joint Explosive Ordnance Disposal (EOD) teams, and for the training of Navy Reservist repair technicians. These Reservists are part of the Robotic Systems Combat Support Platoon (RSCSP), attached to Space and Naval Warfare Systems Center, San Diego. The RSCSP maintains and repairs RSP assets and provides deployable technical support for users of robotic systems. Currently, a small team from the RSCSP is deployed at Camp Victory repairing and maintaining man-portable unmanned ground vehicles (UGVs) used by joint EOD teams in Operation Iraqi Freedom. The focus of this paper is to elaborate on the RSP and RSCSP and their role as invaluable resources for spiral development in the robotics community by gaining first-hand technical feedback from the warfighter and other users.
Rodrigues, Thais Amanda; Goroso, Daniel Gustavo; Westgate, Philip M; Carrico, Cheryl; Batistella, Linamara R; Sawaki, Lumy
2017-10-01
Robot-assisted locomotor training on a bodyweight-supported treadmill is a rehabilitation intervention that compels repetitive practice of gait movements. Standard treadmill speed may elicit rhythmic movements generated primarily by spinal circuits. Slower-than-standard treadmill speed may elicit discrete movements, which are more complex than rhythmic movements and involve cortical areas. Compare effects of fast (i.e., rhythmic) versus slow (i.e., discrete) robot-assisted locomotor training on a bodyweight-supported treadmill in subjects with chronic, severe gait deficit after stroke. Subjects (N = 18) were randomized to receive 30 sessions (5 d/wk) of either fast or slow robot-assisted locomotor training on a bodyweight-supported treadmill in an inpatient setting. Functional ambulation category, time up and go, 6-min walk test, 10-m walk test, Berg Balance Scale, and Fugl-Meyer Assessment were administered at baseline and postintervention. The slow group had statistically significant improvement on functional ambulation category (first quartile-third quartile, P = 0.004), 6-min walk test (95% confidence interval [CI] = 1.8 to 49.0, P = 0.040), Berg Balance Scale (95% CI = 7.4 to 14.8, P < 0.0001), time up and go (95% CI = -79.1 to 5.0, P < 0.0030), and Fugl-Meyer Assessment (95% CI = 24.1 to 45.1, P < 0.0001). The fast group had statistically significant improvement on Berg Balance Scale (95% CI = 1.5 to 10.5, P = 0.02). In initial stages of robot-assisted locomotor training on a bodyweight-supported treadmill after severe stroke, slow training targeting discrete movement may yield greater benefit than fast training.
van Asseldonk, Edwin H F; Veneman, Jan F; Ekkelenkamp, Ralf; Buurke, Jaap H; van der Helm, Frans C T; van der Kooij, Herman
2008-08-01
"Assist as needed" control algorithms promote activity of patients during robotic gait training. Implementing these requires a free walking mode of a device, as unassisted motions should not be hindered. The goal of this study was to assess the normality of walking in the free walking mode of the LOPES gait trainer, an 8 degrees-of-freedom lightweight impedance controlled exoskeleton. Kinematics, gait parameters and muscle activity of walking in a free walking mode in the device were compared with those of walking freely on a treadmill. Average values and variability of the spatio-temporal gait variables showed no or small (relative to cycle-to-cycle variability) changes and the kinematics showed a significant and relevant decrease in knee angle range only. Muscles involved in push off showed a small decrease, whereas muscles involved in acceleration and deceleration of the swing leg showed an increase of their activity. Timing of the activity was mainly unaffected. Most of the observed differences could be ascribed to the inertia of the exoskeleton. Overall, walking with the LOPES resembled free walking, although this required several adaptations in muscle activity. These adaptations are such that we expect that Assist as Needed training can be implemented in LOPES.
Effects of robotically modulating kinematic variability on motor skill learning and motivation
Reinkensmeyer, David J.
2015-01-01
It is unclear how the variability of kinematic errors experienced during motor training affects skill retention and motivation. We used force fields produced by a haptic robot to modulate the kinematic errors of 30 healthy adults during a period of practice in a virtual simulation of golf putting. On day 1, participants became relatively skilled at putting to a near and far target by first practicing without force fields. On day 2, they warmed up at the task without force fields, then practiced with force fields that either reduced or augmented their kinematic errors and were finally assessed without the force fields active. On day 3, they returned for a long-term assessment, again without force fields. A control group practiced without force fields. We quantified motor skill as the variability in impact velocity at which participants putted the ball. We quantified motivation using a self-reported, standardized scale. Only individuals who were initially less skilled benefited from training; for these people, practicing with reduced kinematic variability improved skill more than practicing in the control condition. This reduced kinematic variability also improved self-reports of competence and satisfaction. Practice with increased kinematic variability worsened these self-reports as well as enjoyment. These negative motivational effects persisted on day 3 in a way that was uncorrelated with actual skill. In summary, robotically reducing kinematic errors in a golf putting training session improved putting skill more for less skilled putters. Robotically increasing kinematic errors had no performance effect, but decreased motivation in a persistent way. PMID:25673732
Effects of robotically modulating kinematic variability on motor skill learning and motivation.
Duarte, Jaime E; Reinkensmeyer, David J
2015-04-01
It is unclear how the variability of kinematic errors experienced during motor training affects skill retention and motivation. We used force fields produced by a haptic robot to modulate the kinematic errors of 30 healthy adults during a period of practice in a virtual simulation of golf putting. On day 1, participants became relatively skilled at putting to a near and far target by first practicing without force fields. On day 2, they warmed up at the task without force fields, then practiced with force fields that either reduced or augmented their kinematic errors and were finally assessed without the force fields active. On day 3, they returned for a long-term assessment, again without force fields. A control group practiced without force fields. We quantified motor skill as the variability in impact velocity at which participants putted the ball. We quantified motivation using a self-reported, standardized scale. Only individuals who were initially less skilled benefited from training; for these people, practicing with reduced kinematic variability improved skill more than practicing in the control condition. This reduced kinematic variability also improved self-reports of competence and satisfaction. Practice with increased kinematic variability worsened these self-reports as well as enjoyment. These negative motivational effects persisted on day 3 in a way that was uncorrelated with actual skill. In summary, robotically reducing kinematic errors in a golf putting training session improved putting skill more for less skilled putters. Robotically increasing kinematic errors had no performance effect, but decreased motivation in a persistent way. Copyright © 2015 the American Physiological Society.
Lee, Gyusung I; Lee, Mija R
2018-01-01
While it is often claimed that virtual reality (VR) training system can offer self-directed and mentor-free skill learning using the system's performance metrics (PM), no studies have yet provided evidence-based confirmation. This experimental study investigated what extent to which trainees achieved their self-learning with a current VR simulator and whether additional mentoring improved skill learning, skill transfer and cognitive workloads in robotic surgery simulation training. Thirty-two surgical trainees were randomly assigned to either the Control-Group (CG) or Experiment-Group (EG). While the CG participants reviewed the PM at their discretion, the EG participants had explanations about PM and instructions on how to improve scores. Each subject completed a 5-week training using four simulation tasks. Pre- and post-training data were collected using both a simulator and robot. Peri-training data were collected after each session. Skill learning, time spent on PM (TPM), and cognitive workloads were compared between groups. After the simulation training, CG showed substantially lower simulation task scores (82.9 ± 6.0) compared with EG (93.2 ± 4.8). Both groups demonstrated improved physical model tasks performance with the actual robot, but the EG had a greater improvement in two tasks. The EG exhibited lower global mental workload/distress, higher engagement, and a better understanding regarding using PM to improve performance. The EG's TPM was initially long but substantially shortened as the group became familiar with PM. Our study demonstrated that the current VR simulator offered limited self-skill learning and additional mentoring still played an important role in improving the robotic surgery simulation training.
Training Surgical Residents With a Haptic Robotic Central Venous Catheterization Simulator.
Pepley, David F; Gordon, Adam B; Yovanoff, Mary A; Mirkin, Katelin A; Miller, Scarlett R; Han, David C; Moore, Jason Z
Ultrasound guided central venous catheterization (CVC) is a common surgical procedure with complication rates ranging from 5 to 21 percent. Training is typically performed using manikins that do not simulate anatomical variations such as obesity and abnormal vessel positioning. The goal of this study was to develop and validate the effectiveness of a new virtual reality and force haptic based simulation platform for CVC of the right internal jugular vein. A CVC simulation platform was developed using a haptic robotic arm, 3D position tracker, and computer visualization. The haptic robotic arm simulated needle insertion force that was based on cadaver experiments. The 3D position tracker was used as a mock ultrasound device with realistic visualization on a computer screen. Upon completion of a practice simulation, performance feedback is given to the user through a graphical user interface including scoring factors based on good CVC practice. The effectiveness of the system was evaluated by training 13 first year surgical residents using the virtual reality haptic based training system over a 3 month period. The participants' performance increased from 52% to 96% on the baseline training scenario, approaching the average score of an expert surgeon: 98%. This also resulted in improvement in positive CVC practices including a 61% decrease between final needle tip position and vein center, a decrease in mean insertion attempts from 1.92 to 1.23, and a 12% increase in time spent aspirating the syringe throughout the procedure. A virtual reality haptic robotic simulator for CVC was successfully developed. Surgical residents training on the simulation improved to near expert levels after three robotic training sessions. This suggests that this system could act as an effective training device for CVC. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Comparative assessment of three standardized robotic surgery training methods.
Hung, Andrew J; Jayaratna, Isuru S; Teruya, Kara; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C
2013-10-01
To evaluate three standardized robotic surgery training methods, inanimate, virtual reality and in vivo, for their construct validity. To explore the concept of cross-method validity, where the relative performance of each method is compared. Robotic surgical skills were prospectively assessed in 49 participating surgeons who were classified as follows: 'novice/trainee': urology residents, previous experience <30 cases (n = 38) and 'experts': faculty surgeons, previous experience ≥30 cases (n = 11). Three standardized, validated training methods were used: (i) structured inanimate tasks; (ii) virtual reality exercises on the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA, USA); and (iii) a standardized robotic surgical task in a live porcine model with performance graded by the Global Evaluative Assessment of Robotic Skills (GEARS) tool. A Kruskal-Wallis test was used to evaluate performance differences between novices and experts (construct validity). Spearman's correlation coefficient (ρ) was used to measure the association of performance across inanimate, simulation and in vivo methods (cross-method validity). Novice and expert surgeons had previously performed a median (range) of 0 (0-20) and 300 (30-2000) robotic cases, respectively (P < 0.001). Construct validity: experts consistently outperformed residents with all three methods (P < 0.001). Cross-method validity: overall performance of inanimate tasks significantly correlated with virtual reality robotic performance (ρ = -0.7, P < 0.001) and in vivo robotic performance based on GEARS (ρ = -0.8, P < 0.0001). Virtual reality performance and in vivo tissue performance were also found to be strongly correlated (ρ = 0.6, P < 0.001). We propose the novel concept of cross-method validity, which may provide a method of evaluating the relative value of various forms of skills education and assessment. We externally confirmed the construct validity of each featured training tool. © 2013 BJU International.
Computerized visual feedback: an adjunct to robotic-assisted gait training.
Banz, Raphael; Bolliger, Marc; Colombo, Gery; Dietz, Volker; Lünenburger, Lars
2008-10-01
Robotic devices for walking rehabilitation allow new possibilities for providing performance-related information to patients during gait training. Based on motor learning principles, augmented feedback during robotic-assisted gait training might improve the rehabilitation process used to regain walking function. This report presents a method to provide visual feedback implemented in a driven gait orthosis (DGO). The purpose of the study was to compare the immediate effect on motor output in subjects during robotic-assisted gait training when they used computerized visual feedback and when they followed verbal instructions of a physical therapist. Twelve people with neurological gait disorders due to incomplete spinal cord injury participated. Subjects were instructed to walk within the DGO in 2 different conditions. They were asked to increase their motor output by following the instructions of a therapist and by observing visual feedback. In addition, the subjects' opinions about using visual feedback were investigated by a questionnaire. Computerized visual feedback and verbal instructions by the therapist were observed to result in a similar change in motor output in subjects when walking within the DGO. Subjects reported that they were more motivated and concentrated on their movements when using computerized visual feedback compared with when no form of feedback was provided. Computerized visual feedback is a valuable adjunct to robotic-assisted gait training. It represents a relevant tool to increase patients' motor output, involvement, and motivation during gait training, similar to verbal instructions by a therapist.
Dobkin, Bruce H.; Duncan, Pamela W.
2014-01-01
Body weight–supported treadmill training (BWSTT) and robotic-assisted step training (RAST) have not, so far, led to better outcomes than a comparable dose of progressive over-ground training (OGT) for disabled persons with stroke, spinal cord injury, multiple sclerosis, Parkinson’s disease, or cerebral palsy. The conceptual bases for these promising rehabilitation interventions had once seemed quite plausible, but the results of well-designed, randomized clinical trials have been disappointing. The authors reassess the underpinning concepts for BWSTT and RAST, which were derived from mammalian studies of treadmill-induced hind-limb stepping associated with central pattern generation after low thoracic spinal cord transection, as well as human studies of the triple crown icons of task-oriented locomotor training, massed practice, and activity-induced neuroplasticity. The authors retrospectively consider where theory and practice may have fallen short in the pilot studies that aimed to produce thoroughbred interventions. Based on these shortcomings, the authors move forward with recommendations for the future development of workhorse interventions for walking. In the absence of evidence for physical therapists to employ these strategies, however, BWSTT and RAST should not be provided routinely to disabled, vulnerable persons in place of OGT outside of a scientifically conducted efficacy trial. PMID:22412172
Dobkin, Bruce H; Duncan, Pamela W
2012-05-01
Body weight-supported treadmill training (BWSTT) and robotic-assisted step training (RAST) have not, so far, led to better outcomes than a comparable dose of progressive over-ground training (OGT) for disabled persons with stroke, spinal cord injury, multiple sclerosis, Parkinson's disease, or cerebral palsy. The conceptual bases for these promising rehabilitation interventions had once seemed quite plausible, but the results of well-designed, randomized clinical trials have been disappointing. The authors reassess the underpinning concepts for BWSTT and RAST, which were derived from mammalian studies of treadmill-induced hind-limb stepping associated with central pattern generation after low thoracic spinal cord transection, as well as human studies of the triple crown icons of task-oriented locomotor training, massed practice, and activity-induced neuroplasticity. The authors retrospectively consider where theory and practice may have fallen short in the pilot studies that aimed to produce thoroughbred interventions. Based on these shortcomings, the authors move forward with recommendations for the future development of workhorse interventions for walking. In the absence of evidence for physical therapists to employ these strategies, however, BWSTT and RAST should not be provided routinely to disabled, vulnerable persons in place of OGT outside of a scientifically conducted efficacy trial.
Robotic nurse duties in the urology operative room: 11 years of experience.
Abdel Raheem, Ali; Song, Hyun Jung; Chang, Ki Don; Choi, Young Deuk; Rha, Koon Ho
2017-04-01
The robotic nurse plays an essential role in a successful robotic surgery. As part of the robotic surgical team, the robotic nurse must demonstrate a high level of professional knowledge, and be an expert in robotic technology and dealing with robotic malfunctions. Each one of the robotic nursing team "nurse coordinator, scrub-nurse and circulating-nurse" has a certain job description to ensure maximum patient's safety and robotic surgical efficiency. Well-structured training programs should be offered to the robotic nurse to be well prepared, feel confident, and maintain high-quality of care.
Emken, Jeremy L; Benitez, Raul; Reinkensmeyer, David J
2007-03-28
A prevailing paradigm of physical rehabilitation following neurologic injury is to "assist-as-needed" in completing desired movements. Several research groups are attempting to automate this principle with robotic movement training devices and patient cooperative algorithms that encourage voluntary participation. These attempts are currently not based on computational models of motor learning. Here we assume that motor recovery from a neurologic injury can be modelled as a process of learning a novel sensory motor transformation, which allows us to study a simplified experimental protocol amenable to mathematical description. Specifically, we use a robotic force field paradigm to impose a virtual impairment on the left leg of unimpaired subjects walking on a treadmill. We then derive an "assist-as-needed" robotic training algorithm to help subjects overcome the virtual impairment and walk normally. The problem is posed as an optimization of performance error and robotic assistance. The optimal robotic movement trainer becomes an error-based controller with a forgetting factor that bounds kinematic errors while systematically reducing its assistance when those errors are small. As humans have a natural range of movement variability, we introduce an error weighting function that causes the robotic trainer to disregard this variability. We experimentally validated the controller with ten unimpaired subjects by demonstrating how it helped the subjects learn the novel sensory motor transformation necessary to counteract the virtual impairment, while also preventing them from experiencing large kinematic errors. The addition of the error weighting function allowed the robot assistance to fade to zero even though the subjects' movements were variable. We also show that in order to assist-as-needed, the robot must relax its assistance at a rate faster than that of the learning human. The assist-as-needed algorithm proposed here can limit error during the learning of a dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury.
Hinahon, Erika; Estrada, Christina; Tong, Lin; Won, Deborah S; de Leon, Ray D
2017-08-01
The application of resistive forces has been used during body weight-supported treadmill training (BWSTT) to improve walking function after spinal cord injury (SCI). Whether this form of training actually augments the effects of BWSTT is not yet known. To determine if robotic-applied resistance augments the effects of BWSTT using a controlled experimental design in a rodent model of SCI. Spinally contused rats were treadmill trained using robotic resistance against horizontal (n = 9) or vertical (n = 8) hind limb movements. Hind limb stepping was tested before and after 6 weeks of training. Two control groups, one receiving standard training (ie, without resistance; n = 9) and one untrained (n = 8), were also tested. At the terminal experiment, the spinal cords were prepared for immunohistochemical analysis of synaptophysin. Six weeks of training with horizontal resistance increased step length, whereas training with vertical resistance enhanced step height and movement velocity. None of these changes occurred in the group that received standard (ie, no resistance) training or in the untrained group. Only standard training increased the number of step cycles and shortened cycle period toward normal values. Synaptophysin expression in the ventral horn was highest in rats trained with horizontal resistance and in untrained rats and was positively correlated with step length. Adding robotic-applied resistance to BWSTT produced gains in locomotor function over BWSTT alone. The impact of resistive forces on spinal connections may depend on the nature of the resistive forces and the synaptic milieu that is present after SCI.
Validation of Robotic Surgery Simulator (RoSS).
Kesavadas, Thenkurussi; Stegemann, Andrew; Sathyaseelan, Gughan; Chowriappa, Ashirwad; Srimathveeravalli, Govindarajan; Seixas-Mikelus, Stéfanie; Chandrasekhar, Rameella; Wilding, Gregory; Guru, Khurshid
2011-01-01
Recent growth of daVinci Robotic Surgical System as a minimally invasive surgery tool has led to a call for better training of future surgeons. In this paper, a new virtual reality simulator, called RoSS is presented. Initial results from two studies - face and content validity, are very encouraging. 90% of the cohort of expert robotic surgeons felt that the simulator was excellent or somewhat close to the touch and feel of the daVinci console. Content validity of the simulator received 90% approval in some cases. These studies demonstrate that RoSS has the potential of becoming an important training tool for the daVinci surgical robot.
Niu, Jie; Yang, Qianqian; Wang, Xiaoyun; Song, Rong
2017-01-01
Robot-aided rehabilitation has become an important technology to restore and reinforce motor functions of patients with extremity impairment, whereas it can be extremely challenging to achieve satisfactory tracking performance due to uncertainties and disturbances during rehabilitation training. In this paper, a wire-driven rehabilitation robot that can work over a three-dimensional space is designed for upper-limb rehabilitation, and sliding mode control with nonlinear disturbance observer is designed for the robot to deal with the problem of unpredictable disturbances during robot-assisted training. Then, simulation and experiments of trajectory tracking are carried out to evaluate the performance of the system, the position errors, and the output forces of the designed control scheme are compared with those of the traditional sliding mode control (SMC) scheme. The results show that the designed control scheme can effectively reduce the tracking errors and chattering of the output forces as compared with the traditional SMC scheme, which indicates that the nonlinear disturbance observer can reduce the effect of unpredictable disturbances. The designed control scheme for the wire-driven rehabilitation robot has potential to assist patients with stroke in performing repetitive rehabilitation training.
Lucas, Steven M; Gilley, David A; Joshi, Shreyas S; Gardner, Thomas A; Sundaram, Chandru P
2011-10-01
We present our experience of training residents in a weekend robotic training program to assess its effectiveness and perceived usefulness. Bimonthly training sessions were arranged such that residents could sign up for hour-long, weekend training sessions. They are required to complete four training sessions. Five tasks were scored for time and accuracy: Peg-Board, checkerboard, string running, pattern cutting, and suturing. Participants completed surveys (5-point Likert scale) regarding program utility, ease of attendance, and interest in future weekend training sessions. Mean number of trials completed by 19 residents was >4, and 16 completed the trials within an average of 13.7±8.1 mos. Significant improvements (P<0.05) were seen in final trials for Peg-Board accuracy (95.8% vs 79.0%), checkerboard deviation (4.8% vs 18.2%), and time (293 s vs 404 s), pattern-cutting time (257 s vs 399 s), and suture time (203 s vs 305 s). Time to previous session correlated with relative improvement in Peg-Board and pattern-cutting time (r=0.300 and 0.277, P=0.021 and 0.041), but no specific training interval was predictive of improvement. Residents found the course easy to attend (3.6), noted skills improvement (4.1), and found it useful (4.0). Training in the weekend sessions improved performance of basic tasks on the robot. Training interval had a modest effect on some exercises and may be more important for difficult tasks. This training program is a useful supplement to resident training and would be easy to implement in most programs.
Setting up a pediatric robotic urology program: A USA institution experience.
Murthy, Prithvi B; Schadler, Eric D; Orvieto, Marcelo; Zagaja, Gregory; Shalhav, Arieh L; Gundeti, Mohan S
2018-02-01
Implementing a robotic urological surgery program requires institutional support, and necessitates a comprehensive, detail-oriented plan that accounts for training, oversight, cost and case volume. Given the prevalence of robotic surgery in adult urology, in many instances it might be feasible to implement a pediatric robotic urology program within the greater context of adult urology. This involves, from an institutional standpoint, proportional distribution of equipment cost and operating room time. However, the pediatric urology team primarily determines goals for volume expansion, operative case selection, resident training and surgical innovation within the specialty. In addition to the clinical model, a robust economic model that includes marketing must be present. This review specifically highlights these factors in relationship to establishing and maintaining a pediatric robotic urology program. In addition, we share our data involving robot use over the program's first nine years (December 2007-December 2016). © 2017 The Japanese Urological Association.
An advanced rehabilitation robotic system for augmenting healthcare.
Hu, John; Lim, Yi-Je; Ding, Ye; Paluska, Daniel; Solochek, Aaron; Laffery, David; Bonato, Paolo; Marchessault, Ronald
2011-01-01
Emerging technologies such as rehabilitation robots (RehaBot) for retraining upper and lower limb functions have shown to carry tremendous potential to improve rehabilitation outcomes. Hstar Technologies is developing a revolutionary rehabilitation robot system enhancing healthcare quality for patients with neurological and muscular injuries or functional impairments. The design of RehaBot is a safe and robust system that can be run at a rehabilitation hospital under the direct monitoring and interactive supervision control and at a remote site via telepresence operation control. RehaBot has a wearable robotic structure design like exoskeleton, which employs a unique robotic actuation--Series Elastic Actuator. These electric actuators provide robotic structural compliance, safety, flexibility, and required strength for upper extremity dexterous manipulation rehabilitation training. RehaBot also features a novel non-treadmill paddle platform capable of haptics feedback locomotion rehabilitation training. In this paper, we concern mainly about the motor incomplete patient and rehabilitation applications.
Case Study: Review of Operating Room Utilization at Mayo Clinic Arizona (MCA)
2008-05-01
or CRNA in training. The training of staff and the use of advanced technology, such as the Davinci Surgical Robot, may lead to an increase in time...gynecology performed during block-time will involve the use of the Davinci robot. When using the robot for a case, the set-up and prep-time before...1999). It is because of the cost of surgical staff that block-time lost to delays is concerning. MCA implemented block-time because it provides a tool
ERIC Educational Resources Information Center
Hull, Daniel M.; Lovett, James E.
This report presents the results of research conducted to determine the current state of the art of robotics/automated systems technician (RAST) training offered in the United States. Section I discusses the RAST curriculum project, of which this state-of-the-art review is a part, and offers a RAST job description. Section II describes the…
Video games and surgical ability: a literature review.
Lynch, Jeremy; Aughwane, Paul; Hammond, Toby M
2010-01-01
Surgical training is rapidly evolving because of reduced training hours and the reduction of training opportunities due to patient safety concerns. There is a popular conception that video game usage might be linked to improved operating ability especially those techniques involving endoscopic modalities. If true this might suggest future directions for training. A search was made of the MEDLINE databases for the MeSH term, "Video Games," combined with the terms "Surgical Procedures, Operative," "Endoscopy," "Robotics," "Education," "Learning," "Simulators," "Computer Simulation," "Psychomotor Performance," and "Surgery, Computer-Assisted,"encompassing all journal articles before November 2009. References of articles were searched for further studies. Twelve relevant journal articles were discovered. Video game usage has been studied in relationship to laparoscopic, gastrointestinal endoscopic, endovascular, and robotic surgery. Video game users acquire endoscopic but not robotic techniques quicker, and training on video games appears to improve performance. Copyright (c) 2010 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Active Prior Tactile Knowledge Transfer for Learning Tactual Properties of New Objects
Feng, Di
2018-01-01
Reusing the tactile knowledge of some previously-explored objects (prior objects) helps us to easily recognize the tactual properties of new objects. In this paper, we enable a robotic arm equipped with multi-modal artificial skin, like humans, to actively transfer the prior tactile exploratory action experiences when it learns the detailed physical properties of new objects. These experiences, or prior tactile knowledge, are built by the feature observations that the robot perceives from multiple sensory modalities, when it applies the pressing, sliding, and static contact movements on objects with different action parameters. We call our method Active Prior Tactile Knowledge Transfer (APTKT), and systematically evaluated its performance by several experiments. Results show that the robot improved the discrimination accuracy by around 10% when it used only one training sample with the feature observations of prior objects. By further incorporating the predictions from the observation models of prior objects as auxiliary features, our method improved the discrimination accuracy by over 20%. The results also show that the proposed method is robust against transferring irrelevant prior tactile knowledge (negative knowledge transfer). PMID:29466300
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-26
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-70,749] FANUC Robotics America... negative determination which was based on the finding that, during the relevant period, Fanuc Robotics... Robotics America, Inc., Rochester Hills, Michigan. Signed in Washington, DC, this 13th day of July 2010...
The Robots Are Coming! Training Tomorrow's High-Tech Workers.
ERIC Educational Resources Information Center
Zemke, Ron
1983-01-01
The United States, running second to Japan in the robot race, is employing 19 percent of the world's robots. This article presents six classes of robots that were defined by the Japanese trade association. All are multifunctional, equipped with a memory device, capable of rotation, and able to replace human workers. (SSH)
Robotics. Guidance for Further Education. FEU/PICKUP Project Report.
ERIC Educational Resources Information Center
Further Education Unit, London (England).
This report contains materials to assist teachers and others in designing curricula in robotics. The first section includes the results of a survey of technicians and supervisors in nine companies involved with robots that was designed to gather information concerning the education and training needed to prepare for a career in robotics. The…
Robot-Assisted Thoracic Surgery (RATS): Perioperative Nursing Professional Development Program.
Sarmanian, Julie D
2015-09-01
Robot-assisted surgery continues to grow in popularity worldwide. Competency and training of personnel for robot-assisted thoracic surgery (RATS) is less established compared with other robot-assisted specialties. Major differences between minimally invasive approaches to thoracic surgery (eg, video-assisted thoracoscopic surgery) and RATS are presented to address a paucity of literature on the subject. Although perioperative nursing considerations are universal to all robot-assisted procedures, there are nursing consideration specific to RATS. This article provides a RATS perioperative nursing development program for RN circulators and scrub personnel. Development of perioperative nursing knowledge and skills through implementation of targeted training programs enables nurses to provide a safe surgical experience for patients undergoing RATS. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Ankle Training With a Robotic Device Improves Hemiparetic Gait After a Stroke
Forrester, Larry W.; Roy, Anindo; Krebs, Hermano Igo; Macko, Richard F.
2013-01-01
Background Task-oriented therapies such as treadmill exercise can improve gait velocity after stroke, but slow velocities and abnormal gait patterns often persist, suggesting a need for additional strategies to improve walking. Objectives To determine the effects of a 6-week visually guided, impedance controlled, ankle robotics intervention on paretic ankle motor control and gait function in chronic stroke. Methods This was a single-arm pilot study with a convenience sample of 8 stroke survivors with chronic hemiparetic gait, trained and tested in a laboratory. Subjects trained in dorsiflexion–plantarflexion by playing video games with the robot during three 1-hour training sessions weekly, totaling 560 repetitions per session. Assessments included paretic ankle ranges of motion, strength, motor control, and overground gait function. Results Improved paretic ankle motor control was seen as increased target success, along with faster and smoother movements. Walking velocity also increased significantly, whereas durations of paretic single support increased and double support decreased. Conclusions Robotic feedback training improved paretic ankle motor control with improvements in floor walking. Increased walking speeds were comparable with reports from other task-oriented, locomotor training approaches used in stroke, suggesting that a focus on ankle motor control may provide a valuable adjunct to locomotor therapies. PMID:21115945
Can robotic surgery be done efficiently while training residents?
Honaker, Michael Drew; Paton, Beverly L; Stefanidis, Dimitrios; Schiffern, Lynnette M
2015-01-01
Robotic surgery is a rapidly growing area in surgery. In an era of emphasis on cost reduction, the question becomes how do you train residents in robotic surgery? The aim of this study was to determine if there was a difference in operative time and complications when comparing general surgery residents learning robotic cholecystectomies to those learning standard laparoscopic cholecystectomies. A retrospective analysis of adult patients undergoing robotic and laparoscopic cholecystectomy by surgical residents between March 2013 and February 2014 was conducted. Demographic data, operative factors, length of stay (LOS), and complications were examined. Univariate and multivariate analyses were performed. The significance was set at p < 0.05. A total of 58 patients were included in the study (18 in the robotic cholecystectomy group and 40 in the laparoscopic group). Age, diagnosis, and American Society of Anesthesiologists score were not significantly different between groups. There was only 1 complication in the standard laparoscopic group in which a patient had to be taken back to surgery because of an incarcerated port site. LOS was significantly higher in the standard laparoscopic group (mean = 2.28) than in the robotic group (mean = 0.56; p < 0.0001). Operating room (OR) time was not statistically different between the standard laparoscopic group (mean = 90.98 minutes) and the robotic group (mean = 97.00 minutes; p = 0.4455). When intraoperative cholangiogram was evaluated, OR time was shorter in the robotic group. Robotic training in general surgery residency does not amount to extra OR time. LOS in our study was significantly longer in the standard laparoscopic group. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Feasibility and acceptance of a robotic surgery ergonomic training program.
Franasiak, Jason; Craven, Renatta; Mosaly, Prithima; Gehrig, Paola A
2014-01-01
Assessment of ergonomic strain during robotic surgery indicates there is a need for intervention. However, limited data exist detailing the feasibility and acceptance of ergonomic training (ET) for robotic surgeons. This prospective, observational pilot study evaluates the implementation of an evidence-based ET module. A two-part survey was conducted. The first survey assessed robotic strain using the Nordic Musculoskeletal Questionnaire (NMQ). Participants were given the option to participate in either an online or an in-person ET session. The ET was derived from Occupational Safety and Health Administration guidelines and developed by a human factors engineer experienced with health care ergonomics. After ET, a follow-up survey including the NMQ and an assessment of the ET were completed. The survey was sent to 67 robotic surgeons. Forty-two (62.7%) responded, including 18 residents, 8 fellows, and 16 attending physicians. Forty-five percent experienced strain resulting from performing robotic surgery and 26.3% reported persistent strain. Only 16.6% of surgeons reported prior ET in robotic surgery. Thirty-five (78%) surgeons elected to have in-person ET, which was successfully arranged for 32 surgeons (91.4%). Thirty-seven surgeons (88.1%) completed the follow-up survey. All surgeons participating in the in-person ET found it helpful and felt formal ET should be standard, 88% changed their practice as a result of the training, and 74% of those reporting strain noticed a decrease after their ET. Thus, at a high-volume robotics center, evidence-based ET was easily implemented, well-received, changed some surgeons' practice, and decreased self-reported strain related to robotic surgery.
Improving Emergency Response and Human-Robotic Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
David I. Gertman; David J. Bruemmer; R. Scott Hartley
2007-08-01
Preparedness for chemical, biological, and radiological/nuclear incidents at nuclear power plants (NPPs) includes the deployment of well trained emergency response teams. While teams are expected to do well, data from other domains suggests that the timeliness and accuracy associated with incident response can be improved through collaborative human-robotic interaction. Many incident response scenarios call for multiple, complex procedure-based activities performed by personnel wearing cumbersome personal protective equipment (PPE) and operating under high levels of stress and workload. While robotic assistance is postulated to reduce workload and exposure, limitations associated with communications and the robot’s ability to act independently have servedmore » to limit reliability and reduce our potential to exploit human –robotic interaction and efficacy of response. Recent work at the Idaho National Laboratory (INL) on expanding robot capability has the potential to improve human-system response during disaster management and recovery. Specifically, increasing the range of higher level robot behaviors such as autonomous navigation and mapping, evolving new abstractions for sensor and control data, and developing metaphors for operator control have the potential to improve state-of-the-art in incident response. This paper discusses these issues and reports on experiments underway intelligence residing on the robot to enhance emergency response.« less
Wu, Ming; Kim, Janis; Gaebler-Spira, Deborah J; Schmit, Brian D; Arora, Pooja
2017-11-01
To determine whether applying controlled resistance forces to the legs during the swing phase of gait may improve the efficacy of treadmill training as compared with applying controlled assistance forces in children with cerebral palsy (CP). Randomized controlled study. Research unit of a rehabilitation hospital. Children with spastic CP (N=23; mean age, 10.6y; range, 6-14y; Gross Motor Function Classification System levels, I-IV). Participants were randomly assigned to receive controlled assistance (n=11) or resistance (n=12) loads applied to the legs at the ankle. Participants underwent robotic treadmill training 3 times a week for 6 weeks (18 sessions). A controlled swing assistance/resistance load was applied to both legs starting from the toe-off to mid-swing phase of gait during training. Outcome measures consisted of overground walking speed, 6-minute walk distance, and Gross Motor Function Measure scores and were assessed pre and post 6 weeks of training and 8 weeks after the end of training. After 6 weeks of treadmill training in participants from the resistance training group, fast walking speed and 6-minute walk distance significantly improved (18% and 30% increases, respectively), and 6-minute walk distance was still significantly greater than that at baseline (35% increase) 8 weeks after the end of training. In contrast, overground gait speed and 6-minute walk distance had no significant changes after robotic assistance training. The results of the present study indicated that robotic resistance treadmill training is more effective than assistance training in improving locomotor function in children with CP. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
2010-01-01
Background To improve design of robotic lower limb exoskeletons for gait rehabilitation, it is critical to identify neural mechanisms that govern locomotor adaptation to robotic assistance. Previously, we demonstrated soleus muscle recruitment decreased by ~35% when walking with a pneumatically-powered ankle exoskeleton providing plantar flexor torque under soleus proportional myoelectric control. Since a substantial portion of soleus activation during walking results from the stretch reflex, increased reflex inhibition is one potential mechanism for reducing soleus recruitment when walking with exoskeleton assistance. This is clinically relevant because many neurologically impaired populations have hyperactive stretch reflexes and training to reduce the reflexes could lead to substantial improvements in their motor ability. The purpose of this study was to quantify soleus Hoffmann (H-) reflex responses during powered versus unpowered walking. Methods We tested soleus H-reflex responses in neurologically intact subjects (n=8) that had trained walking with the soleus controlled robotic ankle exoskeleton. Soleus H-reflex was tested at the mid and late stance while subjects walked with the exoskeleton on the treadmill at 1.25 m/s, first without power (first unpowered), then with power (powered), and finally without power again (second unpowered). We also collected joint kinematics and electromyography. Results When the robotic plantar flexor torque was provided, subjects walked with lower soleus electromyographic (EMG) activation (27-48%) and had concomitant reductions in H-reflex amplitude (12-24%) compared to the first unpowered condition. The H-reflex amplitude in proportion to the background soleus EMG during powered walking was not significantly different from the two unpowered conditions. Conclusion These findings suggest that the nervous system does not inhibit the soleus H-reflex in response to short-term adaption to exoskeleton assistance. Future studies should determine if the findings also apply to long-term adaption to the exoskeleton. PMID:20659331
A limit-cycle self-organizing map architecture for stable arm control.
Huang, Di-Wei; Gentili, Rodolphe J; Katz, Garrett E; Reggia, James A
2017-01-01
Inspired by the oscillatory nature of cerebral cortex activity, we recently proposed and studied self-organizing maps (SOMs) based on limit cycle neural activity in an attempt to improve the information efficiency and robustness of conventional single-node, single-pattern representations. Here we explore for the first time the use of limit cycle SOMs to build a neural architecture that controls a robotic arm by solving inverse kinematics in reach-and-hold tasks. This multi-map architecture integrates open-loop and closed-loop controls that learn to self-organize oscillatory neural representations and to harness non-fixed-point neural activity even for fixed-point arm reaching tasks. We show through computer simulations that our architecture generalizes well, achieves accurate, fast, and smooth arm movements, and is robust in the face of arm perturbations, map damage, and variations of internal timing parameters controlling the flow of activity. A robotic implementation is evaluated successfully without further training, demonstrating for the first time that limit cycle maps can control a physical robot arm. We conclude that architectures based on limit cycle maps can be organized to function effectively as neural controllers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin
2017-12-01
The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.
Hakim, Renée M; Tunis, Brandon G; Ross, Michael D
2017-11-01
The focus of research using technological innovations such as robotic devices has been on interventions to improve upper extremity function in neurologic populations, particularly patients with stroke. There is a growing body of evidence describing rehabilitation programs using various types of supportive/assistive and/or resistive robotic and virtual reality-enhanced devices to improve outcomes for patients with neurologic disorders. The most promising approaches are task-oriented, based on current concepts of motor control/learning and practice-induced neuroplasticity. Based on this evidence, we describe application and feasibility of virtual reality-enhanced robotics integrated with current concepts in orthopaedic rehabilitation shifting from an impairment-based focus to inclusion of more intense, task-specific training for patients with upper extremity disorders, specifically emphasizing the wrist and hand. The purpose of this paper is to describe virtual reality-enhanced rehabilitation robotic devices, review evidence of application in patients with upper extremity deficits related to neurologic disorders, and suggest how this technology and task-oriented rehabilitation approach can also benefit patients with orthopaedic disorders of the wrist and hand. We will also discuss areas for further research and development using a task-oriented approach and a commercially available haptic robotic device to focus on training of grasp and manipulation tasks. Implications for Rehabilitation There is a growing body of evidence describing rehabilitation programs using various types of supportive/assistive and/or resistive robotic and virtual reality-enhanced devices to improve outcomes for patients with neurologic disorders. The most promising approaches using rehabilitation robotics are task-oriented, based on current concepts of motor control/learning and practice-induced neuroplasticity. Based on the evidence in neurologic populations, virtual reality-enhanced robotics may be integrated with current concepts in orthopaedic rehabilitation shifting from an impairment-based focus to inclusion of more intense, task-specific training for patients with UE disorders, specifically emphasizing the wrist and hand. Clinical application of a task-oriented approach may be accomplished using commercially available haptic robotic device to focus on training of grasp and manipulation tasks.
Duran, Cassidy; Estrada, Sean; O'Malley, Marcia; Lumsden, Alan B; Bismuth, Jean
2015-02-01
Endovascular robotics systems, now approved for clinical use in the United States and Europe, are seeing rapid growth in interest. Determining who has sufficient expertise for safe and effective clinical use remains elusive. Our aim was to analyze performance on a robotic platform to determine what defines an expert user. During three sessions, 21 subjects with a range of endovascular expertise and endovascular robotic experience (novices <2 hours to moderate-extensive experience with >20 hours) performed four tasks on a training model. All participants completed a 2-hour training session on the robot by a certified instructor. Completion times, global rating scores, and motion metrics were collected to assess performance. Electromagnetic tracking was used to capture and to analyze catheter tip motion. Motion analysis was based on derivations of speed and position including spectral arc length and total number of submovements (inversely proportional to proficiency of motion) and duration of submovements (directly proportional to proficiency). Ninety-eight percent of competent subjects successfully completed the tasks within the given time, whereas 91% of noncompetent subjects were successful. There was no significant difference in completion times between competent and noncompetent users except for the posterior branch (151 s:105 s; P = .01). The competent users had more efficient motion as evidenced by statistically significant differences in the metrics of motion analysis. Users with >20 hours of experience performed significantly better than those newer to the system, independent of prior endovascular experience. This study demonstrates that motion-based metrics can differentiate novice from trained users of flexible robotics systems for basic endovascular tasks. Efficiency of catheter movement, consistency of performance, and learning curves may help identify users who are sufficiently trained for safe clinical use of the system. This work will help identify the learning curve and specific movements that translate to expert robotic navigation. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Robotics: Using Technology to Teach New Technologies.
ERIC Educational Resources Information Center
Cohen, Karen C.; Meyer, Carol D.
1984-01-01
Discusses the development of industrial robotics training materials, considering the need for such materials, preliminary curriculum design, the Piagetian approach followed, and the uses of computer assisted instruction. A list of robotics curriculum courses (with content and audience indicated) is included. (JN)
Energy Efficient Legged Robotics at Sandia Labs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buerger, Steve
Sandia is developing energy efficient actuation and drive train technologies to dramatically improve the charge life of legged robots. The work is supported by DARPA, and Sandia will demonstrate an energy efficient bipedal robot at the technology exposition section of the DARPA Robotics Challenge Finals in June, 2015. This video, the first in a series, describes early development and initial integration of the Sandia Transmission Efficient Prototype Promoting Research (STEPPR) robot.
Energy Efficient Legged Robotics at Sandia Labs
Buerger, Steve
2018-05-07
Sandia is developing energy efficient actuation and drive train technologies to dramatically improve the charge life of legged robots. The work is supported by DARPA, and Sandia will demonstrate an energy efficient bipedal robot at the technology exposition section of the DARPA Robotics Challenge Finals in June, 2015. This video, the first in a series, describes early development and initial integration of the Sandia Transmission Efficient Prototype Promoting Research (STEPPR) robot.
NASA Astrophysics Data System (ADS)
Patkin, M. L.; Rogachev, G. N.
2018-02-01
A method for constructing a multi-agent control system for mobile robots based on training with reinforcement using deep neural networks is considered. Synthesis of the management system is proposed to be carried out with reinforcement training and the modified Actor-Critic method, in which the Actor module is divided into Action Actor and Communication Actor in order to simultaneously manage mobile robots and communicate with partners. Communication is carried out by sending partners at each step a vector of real numbers that are added to the observation vector and affect the behaviour. Functions of Actors and Critic are approximated by deep neural networks. The Critics value function is trained by using the TD-error method and the Actor’s function by using DDPG. The Communication Actor’s neural network is trained through gradients received from partner agents. An environment in which a cooperative multi-agent interaction is present was developed, computer simulation of the application of this method in the control problem of two robots pursuing two goals was carried out.
Medical Robotic and Tele surgical Simulation Education Research
2017-05-01
training exercises, DVSS = 40, dVT = 65, and RoSS = 52 for skills development. All three offer 3D visual images but use different display technologies...capabilities with an emphasis on their educational skills. They offer unique advantages and capabilities in training robotic sur- geons. Each device has been...evaluate the transfer of training effect of each simulator. Collectively, this work will offer end users and potential buyers a comparison of the value
A comparative analysis and guide to virtual reality robotic surgical simulators.
Julian, Danielle; Tanaka, Alyssa; Mattingly, Patricia; Truong, Mireille; Perez, Manuela; Smith, Roger
2018-02-01
Since the US Food and Drug Administration approved robotically assisted surgical devices for human surgery in 2000, the number of surgeries utilizing this innovative technology has risen. In 2015, approximately 650 000 robot-assisted procedures were performed worldwide. Surgeons must be properly trained to safely transition to using such innovative technology. Multiple virtual reality robotic simulators are now commercially available for educational and training purposes. There is a need for comparative evaluations of these simulators to aid users in selecting an appropriate device for their purposes. We conducted a comparison of the design and capabilities of all dedicated simulators of the da Vinci robot - the da Vinci Skills Simulator (dVSS), dV-Trainer (dVT), Robotic Skills Simulators (RoSS) and the RobotiX Mentor. This paper provides the base specifications of the hardware and software, with an emphasis on the training capabilities of each system. Each simulator contains a large number of training exercises for skills development: dVSS n = 40, dVT n = 65, RoSS n = 52, RobotiX Mentor n = 31. All four offer 3D visual images but use different display technologies. The dVSS leverages the real robotic surgical console to provide visualization, hand controls and foot pedals. The dVT, RoSS and RobotiX Mentor created simulated versions of all of these control systems. Each includes systems management services that allow instructors to collect, export and analyze the scores of students using the simulators. This study provides comparative information on the four simulators' functional capabilities. Each device offers unique advantages and capabilities for training robotic surgeons. Each has been the subject of validation experiments, which have been published in the literature. But those do not provide specific details on the capabilities of the simulators, which are necessary for an understanding sufficient to select the one best suited for an organization's needs. This article provides comparative information to assist with that type of selection. Copyright © 2017 John Wiley & Sons, Ltd.
New insights into olivo-cerebellar circuits for learning from a small training sample.
Tokuda, Isao T; Hoang, Huu; Kawato, Mitsuo
2017-10-01
Artificial intelligence such as deep neural networks exhibited remarkable performance in simulated video games and 'Go'. In contrast, most humanoid robots in the DARPA Robotics Challenge fell down to ground. The dramatic contrast in performance is mainly due to differences in the amount of training data, which is huge and small, respectively. Animals are not allowed with millions of the failed trials, which lead to injury and death. Humans fall only several thousand times before they balance and walk. We hypothesize that a unique closed-loop neural circuit formed by the Purkinje cells, the cerebellar deep nucleus and the inferior olive in and around the cerebellum and the highest density of gap junctions, which regulate synchronous activities of the inferior olive nucleus, are computational machinery for learning from a small sample. We discuss recent experimental and computational advances associated with this hypothesis. Copyright © 2017 Elsevier Ltd. All rights reserved.
On the applicability of brain reading for predictive human-machine interfaces in robotics.
Kirchner, Elsa Andrea; Kim, Su Kyoung; Straube, Sirko; Seeland, Anett; Wöhrle, Hendrik; Krell, Mario Michael; Tabie, Marc; Fahle, Manfred
2013-01-01
The ability of today's robots to autonomously support humans in their daily activities is still limited. To improve this, predictive human-machine interfaces (HMIs) can be applied to better support future interaction between human and machine. To infer upcoming context-based behavior relevant brain states of the human have to be detected. This is achieved by brain reading (BR), a passive approach for single trial EEG analysis that makes use of supervised machine learning (ML) methods. In this work we propose that BR is able to detect concrete states of the interacting human. To support this, we show that BR detects patterns in the electroencephalogram (EEG) that can be related to event-related activity in the EEG like the P300, which are indicators of concrete states or brain processes like target recognition processes. Further, we improve the robustness and applicability of BR in application-oriented scenarios by identifying and combining most relevant training data for single trial classification and by applying classifier transfer. We show that training and testing, i.e., application of the classifier, can be carried out on different classes, if the samples of both classes miss a relevant pattern. Classifier transfer is important for the usage of BR in application scenarios, where only small amounts of training examples are available. Finally, we demonstrate a dual BR application in an experimental setup that requires similar behavior as performed during the teleoperation of a robotic arm. Here, target recognition processes and movement preparation processes are detected simultaneously. In summary, our findings contribute to the development of robust and stable predictive HMIs that enable the simultaneous support of different interaction behaviors.
On the Applicability of Brain Reading for Predictive Human-Machine Interfaces in Robotics
Kirchner, Elsa Andrea; Kim, Su Kyoung; Straube, Sirko; Seeland, Anett; Wöhrle, Hendrik; Krell, Mario Michael; Tabie, Marc; Fahle, Manfred
2013-01-01
The ability of today's robots to autonomously support humans in their daily activities is still limited. To improve this, predictive human-machine interfaces (HMIs) can be applied to better support future interaction between human and machine. To infer upcoming context-based behavior relevant brain states of the human have to be detected. This is achieved by brain reading (BR), a passive approach for single trial EEG analysis that makes use of supervised machine learning (ML) methods. In this work we propose that BR is able to detect concrete states of the interacting human. To support this, we show that BR detects patterns in the electroencephalogram (EEG) that can be related to event-related activity in the EEG like the P300, which are indicators of concrete states or brain processes like target recognition processes. Further, we improve the robustness and applicability of BR in application-oriented scenarios by identifying and combining most relevant training data for single trial classification and by applying classifier transfer. We show that training and testing, i.e., application of the classifier, can be carried out on different classes, if the samples of both classes miss a relevant pattern. Classifier transfer is important for the usage of BR in application scenarios, where only small amounts of training examples are available. Finally, we demonstrate a dual BR application in an experimental setup that requires similar behavior as performed during the teleoperation of a robotic arm. Here, target recognition processes and movement preparation processes are detected simultaneously. In summary, our findings contribute to the development of robust and stable predictive HMIs that enable the simultaneous support of different interaction behaviors. PMID:24358125
Autonomous Exploration Using an Information Gain Metric
2016-03-01
implemented on 2 different robotic platforms: the PackBot designed by iRobot and the Jackal designed by Clearpath Robotics. The PackBot, shown in Fig. 1, is a... Jackal is a wheeled, man-portable robot system. Both robots were equipped with a Hokuyo UTM-30LX-EW scanning laser range finder with a motor...Fig. 2, the robot was used to explore and map the second floor of a building located in a military and rescue training facility. The Jackal platform
Robotic gait trainer in water: development of an underwater gait-training orthosis.
Miyoshi, Tasuku; Hiramatsu, Kazuaki; Yamamoto, Shin-Ichiro; Nakazawa, Kimitaka; Akai, Masami
2008-01-01
To develop a robotic gait trainer that can be used in water (RGTW) and achieve repetitive physiological gait patterns to improve the movement dysfunctions. The RGTW is a hip-knee-ankle-foot orthosis with pneumatic actuators; the control software was developed on the basis of the angular motions of the hip and knee joint of a healthy subject as he walked in water. Three-dimensional motions and electromyographic (EMG) activities were recorded in nine healthy subjects to evaluate the efficacy of using the RGTW while walking on a treadmill in water. The device could preserve the angular displacement patterns of the hip and knee and foot trajectories under all experimental conditions. The tibialis anterior EMG activities in the late swing phase and the biceps femoris throughout the stance phase were reduced whose joint torques were assisted by the RGTW while walking on a treadmill in water. Using the RGTW could expect not only the effect of the hydrotherapy but also the standard treadmill gait training, in particular, and may be particularly effective for treating individuals with hip joint movement dysfunction.
Jayaraman, Arun; Burt, Sheila; Rymer, William Zev
2017-07-01
To review lower-limb technology currently available for people with neurological disorders, such as spinal cord injury, stroke, or other conditions. We focus on 3 emerging technologies: treadmill-based training devices, exoskeletons, and other wearable robots. Efficacy for these devices remains unclear, although preliminary data indicate that specific patient populations may benefit from robotic training used with more traditional physical therapy. Potential benefits include improved lower-limb function and a more typical gait trajectory. Use of these devices is limited by insufficient data, cost, and in some cases size of the machine. However, robotic technology is likely to become more prevalent as these machines are enhanced and able to produce targeted physical rehabilitation. Therapists should be aware of these technologies as they continue to advance but understand the limitations and challenges posed with therapeutic/mobility robots.
A self-paced motor imagery based brain-computer interface for robotic wheelchair control.
Tsui, Chun Sing Louis; Gan, John Q; Hu, Huosheng
2011-10-01
This paper presents a simple self-paced motor imagery based brain-computer interface (BCI) to control a robotic wheelchair. An innovative control protocol is proposed to enable a 2-class self-paced BCI for wheelchair control, in which the user makes path planning and fully controls the wheelchair except for the automatic obstacle avoidance based on a laser range finder when necessary. In order for the users to train their motor imagery control online safely and easily, simulated robot navigation in a specially designed environment was developed. This allowed the users to practice motor imagery control with the core self-paced BCI system in a simulated scenario before controlling the wheelchair. The self-paced BCI can then be applied to control a real robotic wheelchair using a protocol similar to that controlling the simulated robot. Our emphasis is on allowing more potential users to use the BCI controlled wheelchair with minimal training; a simple 2-class self paced system is adequate with the novel control protocol, resulting in a better transition from offline training to online control. Experimental results have demonstrated the usefulness of the online practice under the simulated scenario, and the effectiveness of the proposed self-paced BCI for robotic wheelchair control.
Return to Flight: Crew Activities Resource Reel 1 of 2
NASA Technical Reports Server (NTRS)
2005-01-01
The crew of the STS-114 Discovery Mission is seen in various aspects of training for space flight. The crew activities include: 1) STS-114 Return to Flight Crew Photo Session; 2) Tile Repair Training on Precision Air Bearing Floor; 3) SAFER Tile Inspection Training in Virtual Reality Laboratory; 4) Guidance and Navigation Simulator Tile Survey Training; 5) Crew Inspects Orbital Boom and Sensor System (OBSS); 6) Bailout Training-Crew Compartment; 7) Emergency Egress Training-Crew Compartment Trainer (CCT); 8) Water Survival Training-Neutral Buoyancy Lab (NBL); 9) Ascent Training-Shuttle Motion Simulator; 10) External Tank Photo Training-Full Fuselage Trainer; 11) Rendezvous and Docking Training-Shuttle Engineering Simulator (SES) Dome; 12) Shuttle Robot Arm Training-SES Dome; 13) EVA Training Virtual Reality Lab; 14) EVA Training Neutral Buoyancy Lab; 15) EVA-2 Training-NBL; 16) EVA Tool Training-Partial Gravity Simulator; 17) Cure in Place Ablator Applicator (CIPAA) Training Glove Vacuum Chamber; 16) Crew Visit to Merritt Island Launch Area (MILA); 17) Crew Inspection-Space Shuttle Discovery; and 18) Crew Inspection-External Tank and Orbital Boom and Sensor System (OBSS). The crew are then seen answering questions from the media at the Space Shuttle Landing Facility.
Emken, Jeremy L; Benitez, Raul; Reinkensmeyer, David J
2007-01-01
Background A prevailing paradigm of physical rehabilitation following neurologic injury is to "assist-as-needed" in completing desired movements. Several research groups are attempting to automate this principle with robotic movement training devices and patient cooperative algorithms that encourage voluntary participation. These attempts are currently not based on computational models of motor learning. Methods Here we assume that motor recovery from a neurologic injury can be modelled as a process of learning a novel sensory motor transformation, which allows us to study a simplified experimental protocol amenable to mathematical description. Specifically, we use a robotic force field paradigm to impose a virtual impairment on the left leg of unimpaired subjects walking on a treadmill. We then derive an "assist-as-needed" robotic training algorithm to help subjects overcome the virtual impairment and walk normally. The problem is posed as an optimization of performance error and robotic assistance. The optimal robotic movement trainer becomes an error-based controller with a forgetting factor that bounds kinematic errors while systematically reducing its assistance when those errors are small. As humans have a natural range of movement variability, we introduce an error weighting function that causes the robotic trainer to disregard this variability. Results We experimentally validated the controller with ten unimpaired subjects by demonstrating how it helped the subjects learn the novel sensory motor transformation necessary to counteract the virtual impairment, while also preventing them from experiencing large kinematic errors. The addition of the error weighting function allowed the robot assistance to fade to zero even though the subjects' movements were variable. We also show that in order to assist-as-needed, the robot must relax its assistance at a rate faster than that of the learning human. Conclusion The assist-as-needed algorithm proposed here can limit error during the learning of a dynamic motor task. The algorithm encourages learning by decreasing its assistance as a function of the ongoing progression of movement error. This type of algorithm is well suited for helping people learn dynamic tasks for which large kinematic errors are dangerous or discouraging, and thus may prove useful for robot-assisted movement training of walking or reaching following neurologic injury. PMID:17391527
Feasibility and Acceptance of a Robotic Surgery Ergonomic Training Program
Craven, Renatta; Mosaly, Prithima; Gehrig, Paola A.
2014-01-01
Background and Objectives: Assessment of ergonomic strain during robotic surgery indicates there is a need for intervention. However, limited data exist detailing the feasibility and acceptance of ergonomic training (ET) for robotic surgeons. This prospective, observational pilot study evaluates the implementation of an evidence-based ET module. Methods: A two-part survey was conducted. The first survey assessed robotic strain using the Nordic Musculoskeletal Questionnaire (NMQ). Participants were given the option to participate in either an online or an in-person ET session. The ET was derived from Occupational Safety and Health Administration guidelines and developed by a human factors engineer experienced with health care ergonomics. After ET, a follow-up survey including the NMQ and an assessment of the ET were completed. Results: The survey was sent to 67 robotic surgeons. Forty-two (62.7%) responded, including 18 residents, 8 fellows, and 16 attending physicians. Forty-five percent experienced strain resulting from performing robotic surgery and 26.3% reported persistent strain. Only 16.6% of surgeons reported prior ET in robotic surgery. Thirty-five (78%) surgeons elected to have in-person ET, which was successfully arranged for 32 surgeons (91.4%). Thirty-seven surgeons (88.1%) completed the follow-up survey. All surgeons participating in the in-person ET found it helpful and felt formal ET should be standard, 88% changed their practice as a result of the training, and 74% of those reporting strain noticed a decrease after their ET. Conclusion: Thus, at a high-volume robotics center, evidence-based ET was easily implemented, well-received, changed some surgeons' practice, and decreased self-reported strain related to robotic surgery. PMID:25489213
A robotic wheelchair trainer: design overview and a feasibility study
2010-01-01
Background Experiencing independent mobility is important for children with a severe movement disability, but learning to drive a powered wheelchair can be labor intensive, requiring hand-over-hand assistance from a skilled therapist. Methods To improve accessibility to training, we developed a robotic wheelchair trainer that steers itself along a course marked by a line on the floor using computer vision, haptically guiding the driver's hand in appropriate steering motions using a force feedback joystick, as the driver tries to catch a mobile robot in a game of "robot tag". This paper provides a detailed design description of the computer vision and control system. In addition, we present data from a pilot study in which we used the chair to teach children without motor impairment aged 4-9 (n = 22) to drive the wheelchair in a single training session, in order to verify that the wheelchair could enable learning by the non-impaired motor system, and to establish normative values of learning rates. Results and Discussion Training with haptic guidance from the robotic wheelchair trainer improved the steering ability of children without motor impairment significantly more than training without guidance. We also report the results of a case study with one 8-year-old child with a severe motor impairment due to cerebral palsy, who replicated the single-session training protocol that the non-disabled children participated in. This child also improved steering ability after training with guidance from the joystick by an amount even greater than the children without motor impairment. Conclusions The system not only provided a safe, fun context for automating driver's training, but also enhanced motor learning by the non-impaired motor system, presumably by demonstrating through intuitive movement and force of the joystick itself exemplary control to follow the course. The case study indicates that a child with a motor system impaired by CP can also gain a short-term benefit from driver's training with haptic guidance. PMID:20707886
A robotic wheelchair trainer: design overview and a feasibility study.
Marchal-Crespo, Laura; Furumasu, Jan; Reinkensmeyer, David J
2010-08-13
Experiencing independent mobility is important for children with a severe movement disability, but learning to drive a powered wheelchair can be labor intensive, requiring hand-over-hand assistance from a skilled therapist. To improve accessibility to training, we developed a robotic wheelchair trainer that steers itself along a course marked by a line on the floor using computer vision, haptically guiding the driver's hand in appropriate steering motions using a force feedback joystick, as the driver tries to catch a mobile robot in a game of "robot tag". This paper provides a detailed design description of the computer vision and control system. In addition, we present data from a pilot study in which we used the chair to teach children without motor impairment aged 4-9 (n = 22) to drive the wheelchair in a single training session, in order to verify that the wheelchair could enable learning by the non-impaired motor system, and to establish normative values of learning rates. Training with haptic guidance from the robotic wheelchair trainer improved the steering ability of children without motor impairment significantly more than training without guidance. We also report the results of a case study with one 8-year-old child with a severe motor impairment due to cerebral palsy, who replicated the single-session training protocol that the non-disabled children participated in. This child also improved steering ability after training with guidance from the joystick by an amount even greater than the children without motor impairment. The system not only provided a safe, fun context for automating driver's training, but also enhanced motor learning by the non-impaired motor system, presumably by demonstrating through intuitive movement and force of the joystick itself exemplary control to follow the course. The case study indicates that a child with a motor system impaired by CP can also gain a short-term benefit from driver's training with haptic guidance.
Energy Efficient Legged Robotics at Sandia Labs, Part 2
Buerger, Steve; Mazumdar, Ani; Spencer, Steve
2018-01-16
Sandia is developing energy efficient actuation and drive train technologies to dramatically improve the charge life of legged robots. The work is supported by DARPA, and Sandia will demonstrate an energy efficient bipedal robot at the technology exposition section of the DARPA Robotics Challenge Finals in June, 2015. This video, the second in a series, describes the continued development and integration of the Sandia Transmission Efficient Prototype Promoting Research (STEPPR) robot.
Energy Efficient Legged Robotics at Sandia Labs, Part 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buerger, Steve; Mazumdar, Ani; Spencer, Steve
Sandia is developing energy efficient actuation and drive train technologies to dramatically improve the charge life of legged robots. The work is supported by DARPA, and Sandia will demonstrate an energy efficient bipedal robot at the technology exposition section of the DARPA Robotics Challenge Finals in June, 2015. This video, the second in a series, describes the continued development and integration of the Sandia Transmission Efficient Prototype Promoting Research (STEPPR) robot.
Lee, Gyusung I; Lee, Mija R; Clanton, Tameka; Clanton, Tamera; Sutton, Erica; Park, Adrian E; Marohn, Michael R
2014-02-01
We conducted this study to investigate how physical and cognitive ergonomic workloads would differ between robotic and laparoscopic surgeries and whether any ergonomic differences would be related to surgeons' robotic surgery skill level. Our hypothesis is that the unique features in robotic surgery will demonstrate skill-related results both in substantially less physical and cognitive workload and uncompromised task performance. Thirteen MIS surgeons were recruited for this institutional review board-approved study and divided into three groups based on their robotic surgery experiences: laparoscopy experts with no robotic experience, novices with no or little robotic experience, and robotic experts. Each participant performed six surgical training tasks using traditional laparoscopy and robotic surgery. Physical workload was assessed by using surface electromyography from eight muscles (biceps, triceps, deltoid, trapezius, flexor carpi ulnaris, extensor digitorum, thenar compartment, and erector spinae). Mental workload assessment was conducted using the NASA-TLX. The cumulative muscular workload (CMW) from the biceps and the flexor carpi ulnaris with robotic surgery was significantly lower than with laparoscopy (p < 0.05). Interestingly, the CMW from the trapezius was significantly higher with robotic surgery than with laparoscopy (p < 0.05), but this difference was only observed in laparoscopic experts (LEs) and robotic surgery novices. NASA-TLX analysis showed that both robotic surgery novices and experts expressed lower global workloads with robotic surgery than with laparoscopy, whereas LEs showed higher global workload with robotic surgery (p > 0.05). Robotic surgery experts and novices had significantly higher performance scores with robotic surgery than with laparoscopy (p < 0.05). This study demonstrated that the physical and cognitive ergonomics with robotic surgery were significantly less challenging. Additionally, several ergonomic components were skill-related. Robotic experts could benefit the most from the ergonomic advantages in robotic surgery. These results emphasize the need for well-structured training and well-defined ergonomics guidelines to maximize the benefits utilizing the robotic surgery.
Ockenfeld, Corinna; Tong, Raymond K Y; Susanto, Evan A; Ho, Sze-Kit; Hu, Xiao-ling
2013-06-01
Background and Purpose. Stroke survivors often show a limited recovery in the hand function to perform delicate motions, such as full hand grasping, finger pinching and individual finger movement. The purpose of this study is to describe the implementation of an exoskeleton robotic hand together with fine finger motor skill training on 2 chronic stroke patients. Case Descriptions. Two post-stroke patients participated in a 20-session training program by integrating 10 minutes physical therapy, 20 minutes robotic hand training and 15 minutes functional training tasks with delicate objects(card, pen and coin). These two patients (A and B) had cerebrovascular accident at 6 months and 11 months respectively when enrolled in this study. Outcomes. The results showed that both patients had improvements in Fugl-Meyer assessment (FM), Action Research Arm Test (ARAT). Patients had better isolation of the individual finger flexion and extension based on the reduced muscle co-contraction from the electromyographic(EMG) signals and finger extension force after 20 sessions of training. Discussion. This preliminary study showed that by focusing on the fine finger motor skills together with the exoskeleton robotic hand, it could improve the motor recovery of the upper extremity in the fingers and hand function, which were showed in the ARAT. Future randomized controlled trials are needed to evaluate the clinical effectiveness.
Swerdlow, Daniel R; Cleary, Kevin; Wilson, Emmanuel; Azizi-Koutenaei, Bamshad; Monfaredi, Reza
2017-04-01
Ultrasound imaging requires trained personnel. Advances in robotics and data transmission create the possibility of telesonography. This review introduces clinicians to current technical work in and potential applications of this developing capability. Telesonography offers advantages in hazardous or remote environments. Robotically assisted ultrasound can reduce stress injuries in sonographers and has potential utility during robotic surgery and interventional procedures.
NASA Astrophysics Data System (ADS)
Zheng, Taixiong
2005-12-01
A neuro-fuzzy network based approach for robot motion in an unknown environment was proposed. In order to control the robot motion in an unknown environment, the behavior of the robot was classified into moving to the goal and avoiding obstacles. Then, according to the dynamics of the robot and the behavior character of the robot in an unknown environment, fuzzy control rules were introduced to control the robot motion. At last, a 6-layer neuro-fuzzy network was designed to merge from what the robot sensed to robot motion control. After being trained, the network may be used for robot motion control. Simulation results show that the proposed approach is effective for robot motion control in unknown environment.
Consistency of performance of robot-assisted surgical tasks in virtual reality.
Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N
2009-01-01
The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.
2009-01-01
Background In the last two decades robot training in neuromotor rehabilitation was mainly focused on shoulder-elbow movements. Few devices were designed and clinically tested for training coordinated movements of the wrist, which are crucial for achieving even the basic level of motor competence that is necessary for carrying out ADLs (activities of daily life). Moreover, most systems of robot therapy use point-to-point reaching movements which tend to emphasize the pathological tendency of stroke patients to break down goal-directed movements into a number of jerky sub-movements. For this reason we designed a wrist robot with a range of motion comparable to that of normal subjects and implemented a self-adapting training protocol for tracking smoothly moving targets in order to facilitate the emergence of smoothness in the motor control patterns and maximize the recovery of the normal RoM (range of motion) of the different DoFs (degrees of Freedom). Methods The IIT-wrist robot is a 3 DoFs light exoskeleton device, with direct-drive of each DoF and a human-like range of motion for Flexion/Extension (FE), Abduction/Adduction (AA) and Pronation/Supination (PS). Subjects were asked to track a variable-frequency oscillating target using only one wrist DoF at time, in such a way to carry out a progressive splinting therapy. The RoM of each DoF was angularly scanned in a staircase-like fashion, from the "easier" to the "more difficult" angular position. An Adaptive Controller evaluated online performance parameters and modulated both the assistance and the difficulty of the task in order to facilitate smoother and more precise motor command patterns. Results Three stroke subjects volunteered to participate in a preliminary test session aimed at verify the acceptability of the device and the feasibility of the designed protocol. All of them were able to perform the required task. The wrist active RoM of motion was evaluated for each patient at the beginning and at the end of the test therapy session and the results suggest a positive trend. Conclusion The positive outcomes of the preliminary tests motivate the planning of a clinical trial and provide experimental evidence for defining appropriate inclusion/exclusion criteria. PMID:19968873
Validated robotic laparoscopic surgical training in a virtual-reality environment.
Katsavelis, Dimitrios; Siu, Ka-Chun; Brown-Clerk, Bernadette; Lee, Irene H; Lee, Yong Kwon; Oleynikov, Dmitry; Stergiou, Nick
2009-01-01
A robotic virtual-reality (VR) simulator has been developed to improve robot-assisted training for laparoscopic surgery and to enhance surgical performance in laparoscopic skills. The simulated VR training environment provides an effective approach to evaluate and improve surgical performance. This study presents our findings of the VR training environment for robotic laparoscopy. Eight volunteers performed two inanimate tasks in both the VR and the actual training environment. The tasks were bimanual carrying (BC) and needle passing (NP). For the BC task, the volunteers simultaneously transferred two plastic pieces in opposite directions five times consecutively. The same volunteers passed a surgical needle through six pairs of holes in the NP task. Both tasks require significant bimanual coordination that mimics actual laparoscopic skills. Data analysis included time to task completion, speed and distance traveled of the instrument tip, as well as range of motion of the subject's wrist and elbow of the right arm. Electromyography of the right wrist flexor and extensor were also analyzed. Paired t-tests and Pearson's r were used to explore the differences and correlations between the two environments. There were no significant differences between the actual and the simulated VR environment with respect to the BC task, while there were significant differences in almost all dependent parameters for the NP task. Moderate to high correlations for most dependent parameters were revealed for both tasks. Our data shows that the VR environment adequately simulated the BC task. The significant differences found for the NP task may be attributed to an oversimplification in the VR environment. However, they do point to the need for improvements in the complexity of our VR simulation. Further research work is needed to develop effective and reliable VR environments for robotic laparoscopic training.
Utilization of robotic "remote presence" technology within North American intensive care units.
Reynolds, Eliza M; Grujovski, Andre; Wright, Tim; Foster, Michael; Reynolds, H Neal
2012-09-01
To describe remote presence robotic utilization and examine perceived physician impact upon care in the intensive care unit (ICU). Data were obtained from academic, university, community, and rural medical facilities in North America with remote presence robots used in ICUs. Objective utilization data were extracted from a continuous monitoring system. Physician data were obtained via an Internet-based survey. As of 2010, 56 remote presence robots were deployed in 25 North American ICUs. Of 10,872 robot activations recorded, 10,065 were evaluated. Three distinct utilization patterns were discovered. Combining all programs revealed a pattern that closely reflects diurnal ICU activity. The physician survey revealed staff are senior (75% >40 years old, 60% with >16 years of clinical practice), trained in and dedicated to critical care. Programs are mature (70% >3 years old) and operate in a decentralized system, originating from cities with >50,000 population and provided to cities >50,000 (80%). Of the robots, 46.6% are in academic facilities. Most physicians (80%) provide on-site and remote ICU care, with 60% and 73% providing routine or scheduled rounds, respectively. All respondents (100%) believed patient care and patient/family satisfaction were improved. Sixty-six percent perceived the technology was a "blessing," while 100% intend to continue using the technology. Remote presence robotic technology is deployed in ICUs with various patterns of utilization that, in toto, simulate normal ICU work flow. There is a high rate of deployment in academic ICUs, suggesting the intensivists shortage also affects large facilities. Physicians using the technology are generally senior, experienced, and dedicated to critical care and highly support the technology.
Udoekwere, Ubong I.; Oza, Chintan S.
2016-01-01
Robot therapy promotes functional recovery after spinal cord injury (SCI) in animal and clinical studies. Trunk actions are important in adult rats spinalized as neonates (NTX rats) that walk autonomously. Quadrupedal robot rehabilitation was tested using an implanted orthosis at the pelvis. Trunk cortical reorganization follows such rehabilitation. Here, we test the functional outcomes of such training. Robot impedance control at the pelvis allowed hindlimb, trunk, and forelimb mechanical interactions. Rats gradually increased weight support. Rats showed significant improvement in hindlimb stepping ability, quadrupedal weight support, and all measures examined. Function in NTX rats both before and after training showed bimodal distributions, with “poor” and “high weight support” groupings. A total of 35% of rats initially classified as “poor” were able to increase their weight-supported step measures to a level considered “high weight support” after robot training, thus moving between weight support groups. Recovered function in these rats persisted on treadmill with the robot both actuated and nonactuated, but returned to pretraining levels if they were completely disconnected from the robot. Locomotor recovery in robot rehabilitation of NTX rats thus likely included context dependence and/or incorporation of models of robot mechanics that became essential parts of their learned strategy. Such learned dependence is likely a hurdle to autonomy to be overcome for many robot locomotor therapies. Notwithstanding these limitations, trunk-based quadrupedal robot rehabilitation helped the rats to visit mechanical states they would never have achieved alone, to learn novel coordinations, and to achieve major improvements in locomotor function. SIGNIFICANCE STATEMENT Neonatal spinal transected rats without any weight support can be taught weight support as adults by using robot rehabilitation at trunk. No adult control rats with neonatal spinal transections spontaneously achieve similar changes. The robot rehabilitation system can be inactivated and the skills that were learned persist. Responding rats cannot be detached from the robot altogether, a dependence develops in the skill learned. From data and analysis here, the likelihood of such rats to respond to the robot therapy can also now be predicted. These results are all novel. Understanding trunk roles in voluntary and spinal reflex integration after spinal cord injury and in recovery of function are broadly significant for basic and clinical understanding of motor function. PMID:27511008
Udoekwere, Ubong I; Oza, Chintan S; Giszter, Simon F
2016-08-10
Robot therapy promotes functional recovery after spinal cord injury (SCI) in animal and clinical studies. Trunk actions are important in adult rats spinalized as neonates (NTX rats) that walk autonomously. Quadrupedal robot rehabilitation was tested using an implanted orthosis at the pelvis. Trunk cortical reorganization follows such rehabilitation. Here, we test the functional outcomes of such training. Robot impedance control at the pelvis allowed hindlimb, trunk, and forelimb mechanical interactions. Rats gradually increased weight support. Rats showed significant improvement in hindlimb stepping ability, quadrupedal weight support, and all measures examined. Function in NTX rats both before and after training showed bimodal distributions, with "poor" and "high weight support" groupings. A total of 35% of rats initially classified as "poor" were able to increase their weight-supported step measures to a level considered "high weight support" after robot training, thus moving between weight support groups. Recovered function in these rats persisted on treadmill with the robot both actuated and nonactuated, but returned to pretraining levels if they were completely disconnected from the robot. Locomotor recovery in robot rehabilitation of NTX rats thus likely included context dependence and/or incorporation of models of robot mechanics that became essential parts of their learned strategy. Such learned dependence is likely a hurdle to autonomy to be overcome for many robot locomotor therapies. Notwithstanding these limitations, trunk-based quadrupedal robot rehabilitation helped the rats to visit mechanical states they would never have achieved alone, to learn novel coordinations, and to achieve major improvements in locomotor function. Neonatal spinal transected rats without any weight support can be taught weight support as adults by using robot rehabilitation at trunk. No adult control rats with neonatal spinal transections spontaneously achieve similar changes. The robot rehabilitation system can be inactivated and the skills that were learned persist. Responding rats cannot be detached from the robot altogether, a dependence develops in the skill learned. From data and analysis here, the likelihood of such rats to respond to the robot therapy can also now be predicted. These results are all novel. Understanding trunk roles in voluntary and spinal reflex integration after spinal cord injury and in recovery of function are broadly significant for basic and clinical understanding of motor function. Copyright © 2016 the authors 0270-6474/16/368341-15$15.00/0.
Hussein, S; Schmidt, H; Volkmar, M; Werner, C; Helmich, I; Piorko, F; Krüger, J; Hesse, S
2008-01-01
The aim of gait rehabilitation is a restoration of an independent gait and improvement of daily life walking functions. Therefore the specific patterns, that are to be relearned, must be practiced to stimulate the learning process of the central nervous system (CNS). The Walking Simulator HapticWalker allows for the training of arbitrary gait trajectories of daily life. To evaluate the quality of the training a total of 9 subjects were investigated during free floor walking and stair climbing and during the same tasks in two different training modes on the HapticWalker: 1) with and 2) without vertical center of mass (CoM) motion. Electromyograms (EMG) of 8 gait relevant muscles were measured and muscle activation was compared for the various training modes. Besides the muscle activation as an indicator for the quality of rehabilitation training the study investigates if a cancellation of the vertical CoM movement by adaption of the footplate trajectory is feasible i.e. the muscle activation patterns for the two training modes on the HapticWalker agree. Results show no significant differences in activation timing between the training modes. This indicates the feasibility of using a passive patient suspension and emulate the vertical CoM motion by trajectory adaption of the footplates. The muscle activation timing during HapticWalker training shows important characteristics observed in physiological free walking though a few differences can still remain.
Views of physiatrists and physical therapists on the use of gait-training robots for stroke patients
Kang, Chang Gu; Chun, Min Ho; Chang, Min Cheol; Kim, Won; Hee Do, Kyung
2016-01-01
[Purpose] Gait-training robots have been developed for stroke patients with gait disturbance. It is important to survey the views of physiatrists and physical therapists on the characteristics of these devices during their development. [Subjects and Methods] A total of 100 physiatrists and 100 physical therapists from 38 hospitals participated in our questionnaire survey. [Results] The most common answers about the merits of gait-training robots concern improving the treatment effects (28.5%), followed by standardizing treatment (19%), motivating patients about treatment (17%), and improving patients’ self-esteem (14%). The subacute period (1–3 months post-stroke onset) was most often chosen as the ideal period (47.3%) for the use of these devices, and a functional ambulation classification of 0–2 was the most selected response for the optimal patient status (27%). The preferred model was the treadmill type (47.5%) over the overground walking type (40%). The most favored commercial price was $50,000–$100,000 (38.3%). The most selected optimal duration for robot-assisted gait therapy was 30–45 min (47%), followed by 15–30 min (29%), 45–60 min (18%), ≥ 60 min (5%), and < 15 min (1%). [Conclusion] Our study findings could guide the future designs of more effective gait-training robots for stroke patients. PMID:26957758
Tomelleri, Christopher; Waldner, Andreas; Werner, Cordula; Hesse, Stefan
2011-01-01
The main goal of robotic gait rehabilitation is the restoration of independent gait. To achieve this goal different and specific patterns have to be practiced intensively in order to stimulate the learning process of the central nervous system. The gait robot G-EO Systems was designed to allow the repetitive practice of floor walking, stair climbing and stair descending. A novel control strategy allows training in adaptive mode. The force interactions between the foot and the ground were analyzed on 8 healthy volunteers in three different conditions: real floor walking on a treadmill, floor walking on the gait robot in passive mode, floor walking on the gait robot in adaptive mode. The ground reaction forces were measured by a Computer Dyno Graphy (CDG) analysis system. The results show different intensities of the ground reaction force across all of the three conditions. The intensities of force interactions during the adaptive training mode are comparable to the real walking on the treadmill. Slight deviations still occur in regard to the timing pattern of the forces. The adaptive control strategy comes closer to the physiological swing phase than the passive mode and seems to be a promising option for the treatment of gait disorders. Clinical trials will validate the efficacy of this new option in locomotor therapy on the patients. © 2011 IEEE
A Dynamic Compliance Cervix Phantom Robot for Latent Labor Simulation.
Luk, Michelle Jennifer; Lobb, Derek; Smith, James Andrew
2018-06-01
Physical simulation systems are commonly used in training of midwifery and obstetrics students, but none of these systems offers a dynamic compliance aspect that would make them more truly representative of cervix ripening. In this study, we introduce a unique soft robot phantom that simulates the cervix softening during the latent labor phase of birth. This proof-of-concept robotic phantom can be dilated by 1 cm and effaced by 35% through the application of a Foley catheter-like loading mechanism. Furthermore, psychophysics trials demonstrate how untrained subjects can identify hard and soft states of the phantom with specificities of 91% and 87%, respectively. Both results indicated the appropriateness for application of this soft robot technology to birth training simulators.
Evolution of robotics in surgery and implementing a perioperative robotics nurse specialist role.
Francis, Paula
2006-03-01
Use of robotics is expanding rapidly in the medical arena. Not only are a growing number of facilities purchasing robotic systems, but the number of surgeons using them also is increasing, which creates many challenges (eg, cost, training, safety). The evolution of robotics in surgery is presented within the context of virtual reality, telepresence, telemanipulation, and passive (ie, master-slave) robotic surgical systems. A new perioperative nursing role, the robotics nurse specialist, was developed and implemented at one facility. The need for a robotics nurse specialist and how this role can help the entire surgical team promote positive patient and facility outcomes also is discussed.
Using advanced computer vision algorithms on small mobile robots
NASA Astrophysics Data System (ADS)
Kogut, G.; Birchmore, F.; Biagtan Pacis, E.; Everett, H. R.
2006-05-01
The Technology Transfer project employs a spiral development process to enhance the functionality and autonomy of mobile robot systems in the Joint Robotics Program (JRP) Robotic Systems Pool by converging existing component technologies onto a transition platform for optimization. An example of this approach is the implementation of advanced computer vision algorithms on small mobile robots. We demonstrate the implementation and testing of the following two algorithms useful on mobile robots: 1) object classification using a boosted Cascade of classifiers trained with the Adaboost training algorithm, and 2) human presence detection from a moving platform. Object classification is performed with an Adaboost training system developed at the University of California, San Diego (UCSD) Computer Vision Lab. This classification algorithm has been used to successfully detect the license plates of automobiles in motion in real-time. While working towards a solution to increase the robustness of this system to perform generic object recognition, this paper demonstrates an extension to this application by detecting soda cans in a cluttered indoor environment. The human presence detection from a moving platform system uses a data fusion algorithm which combines results from a scanning laser and a thermal imager. The system is able to detect the presence of humans while both the humans and the robot are moving simultaneously. In both systems, the two aforementioned algorithms were implemented on embedded hardware and optimized for use in real-time. Test results are shown for a variety of environments.
Hwang, Jongseok; Shin, Yongil; Park, Ji-Ho; Cha, Young Joo; You, Joshua Sung H
2018-04-07
The robotic-assisted gait training (RAGT) system has gained recognition as an innovative, effective paradigm to improve functional ambulation and activities of daily living in spinal cord injury and stroke. However, the effects of the Walkbot robotic-assisted gait training system with a specialized hip-knee-ankle actuator have never been examined in the paraplegia and quadriplegia population. The aim of this study was to determine the long-term effects of Walkbot training on clinical for hips and knee stiffness in individuals with paraplegia or quadriplegia. Nine adults with subacute or chronic paraplegia resulting from spinal cord injury or quadriplegia resulting from cerebral vascular accident (CVA) and/or hypoxia underwent progressive conventional gait retraining combined with the Walkbot RAGT for 5 days/week over an average of 43 sessions for 8 weeks. Clinical outcomes were measured with the Functional Ambulation Category (FAC), Modified Rankin Scale (MRS), Korean version of the Modified Barthel Index (K-MBI), Modified Ashworth Scale (MAS). Kinetic and kinematic data were collected via a built-in Walkbot program. Wilcoxon signed-rank tests showed significant positive intervention effects on K-MBI, maximal hip flexion and extension, maximal knee flexion, active torque in the knee joint, resistive torque, and stiffness in the hip joint (P < 0.05). These findings suggest that the Walkbot RAGT was effective for improving knee and hip kinematics and the active knee joint moment while decreasing hip resistive force. These improvements were associated with functional recovery in gait, balance, mobility and daily activities. These findings suggest that the Walkbot RAGT was effective for improving knee and hip kinematics and the active knee joint moment while decreasing hip resistive force. This is the first clinical evidence for intensive, long-term effects of the Walkbot RAGT on active or resistive moments and stiffness associated with spasticity and functional mobility in individuals with subacute or chronic paraplegia or quadriplegia who had reached a plateau in motor recovery after conventional therapy.
Wireless intraoral tongue control of an assistive robotic arm for individuals with tetraplegia.
Andreasen Struijk, Lotte N S; Egsgaard, Line Lindhardt; Lontis, Romulus; Gaihede, Michael; Bentsen, Bo
2017-11-06
For an individual with tetraplegia assistive robotic arms provide a potentially invaluable opportunity for rehabilitation. However, there is a lack of available control methods to allow these individuals to fully control the assistive arms. Here we show that it is possible for an individual with tetraplegia to use the tongue to fully control all 14 movements of an assistive robotic arm in a three dimensional space using a wireless intraoral control system, thus allowing for numerous activities of daily living. We developed a tongue-based robotic control method incorporating a multi-sensor inductive tongue interface. One abled-bodied individual and one individual with tetraplegia performed a proof of concept study by controlling the robot with their tongue using direct actuator control and endpoint control, respectively. After 30 min of training, the able-bodied experimental participant tongue controlled the assistive robot to pick up a roll of tape in 80% of the attempts. Further, the individual with tetraplegia succeeded in fully tongue controlling the assistive robot to reach for and touch a roll of tape in 100% of the attempts and to pick up the roll in 50% of the attempts. Furthermore, she controlled the robot to grasp a bottle of water and pour its contents into a cup; her first functional action in 19 years. To our knowledge, this is the first time that an individual with tetraplegia has been able to fully control an assistive robotic arm using a wireless intraoral tongue interface. The tongue interface used to control the robot is currently available for control of computers and of powered wheelchairs, and the robot employed in this study is also commercially available. Therefore, the presented results may translate into available solutions within reasonable time.
2010-01-01
Background Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. Methods The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. Results The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. Conclusions The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies. PMID:20584307
Hesse, Stefan; Waldner, Andreas; Tomelleri, Christopher
2010-06-28
Stair climbing up and down is an essential part of everyday's mobility. To enable wheelchair-dependent patients the repetitive practice of this task, a novel gait robot, G-EO-Systems (EO, Lat: I walk), based on the end-effector principle, has been designed. The trajectories of the foot plates are freely programmable enabling not only the practice of simulated floor walking but also stair climbing up and down. The article intended to compare lower limb muscle activation patterns of hemiparetic subjects during real floor walking and stairs climbing up, and during the corresponding simulated conditions on the machine, and secondly to demonstrate gait improvement on single case after training on the machine. The muscle activation pattern of seven lower limb muscles of six hemiparetic patients during free and simulated walking on the floor and stair climbing was measured via dynamic electromyography. A non-ambulatory, sub-acute stroke patient additionally trained on the G-EO-Systems every workday for five weeks. The muscle activation patterns were comparable during the real and simulated conditions, both on the floor and during stair climbing up. Minor differences, concerning the real and simulated floor walking conditions, were a delayed (prolonged) onset (duration) of the thigh muscle activation on the machine across all subjects. Concerning stair climbing conditions, the shank muscle activation was more phasic and timely correct in selected patients on the device. The severely affected subject regained walking and stair climbing ability. The G-EO-Systems is an interesting new option in gait rehabilitation after stroke. The lower limb muscle activation patterns were comparable, a training thus feasible, and the positive case report warrants further clinical studies.
Decoding bipedal locomotion from the rat sensorimotor cortex.
Rigosa, J; Panarese, A; Dominici, N; Friedli, L; van den Brand, R; Carpaneto, J; DiGiovanna, J; Courtine, G; Micera, S
2015-10-01
Decoding forelimb movements from the firing activity of cortical neurons has been interfaced with robotic and prosthetic systems to replace lost upper limb functions in humans. Despite the potential of this approach to improve locomotion and facilitate gait rehabilitation, decoding lower limb movement from the motor cortex has received comparatively little attention. Here, we performed experiments to identify the type and amount of information that can be decoded from neuronal ensemble activity in the hindlimb area of the rat motor cortex during bipedal locomotor tasks. Rats were trained to stand, step on a treadmill, walk overground and climb staircases in a bipedal posture. To impose this gait, the rats were secured in a robotic interface that provided support against the direction of gravity and in the mediolateral direction, but behaved transparently in the forward direction. After completion of training, rats were chronically implanted with a micro-wire array spanning the left hindlimb motor cortex to record single and multi-unit activity, and bipolar electrodes into 10 muscles of the right hindlimb to monitor electromyographic signals. Whole-body kinematics, muscle activity, and neural signals were simultaneously recorded during execution of the trained tasks over multiple days of testing. Hindlimb kinematics, muscle activity, gait phases, and locomotor tasks were decoded using offline classification algorithms. We found that the stance and swing phases of gait and the locomotor tasks were detected with accuracies as robust as 90% in all rats. Decoded hindlimb kinematics and muscle activity exhibited a larger variability across rats and tasks. Our study shows that the rodent motor cortex contains useful information for lower limb neuroprosthetic development. However, brain-machine interfaces estimating gait phases or locomotor behaviors, instead of continuous variables such as limb joint positions or speeds, are likely to provide more robust control strategies for the design of such neuroprostheses.
Park, Wanjoo; Jeong, Wookjin; Kwon, Gyu-Hyun; Kim, Yun-Hee; Kim, Laehyun
2013-06-01
This paper proposes a robotic hand rehabilitation device for grasp training. The device is designed for stroke patients to train and recover their hand grasp function in order to undertake activities of daily living (ADL). The device consists of a control unit, two small actuators, an infrared (IR) sensor, and pressure sensors in the grasp handle. The advantages of this device are that it is small in size, inexpensive, and available for use at home without specialist's supervision. In addition, a novel patient-driven strategy based on the patient's movement intention detected by the pressure sensors without bio-signals is introduced. Once the system detects a patient's movement intention, it triggers the robotic device to move the patient's hand to form the normal grasping behavior. This strategy may encourage stroke patients to participate in rehabilitation training to recover their hand grasp function and it may also enhance neural plasticity. A user study was conducted in order to investigate the usability, acceptability, satisfaction, and suggestions for improvement of the proposed device. The results of this survey included positive reviews from therapists and a stroke patient. In particular, therapists expected that the proposed patient-driven mode can motivate patients for their rehabilitation training and it can be effective to prevent a compensational strategy in active movements. It is expected that the proposed device will assist stroke patients in restoring their grasp function efficiently.
Kim, Youngmoo E.
2017-01-01
Motor-imagery tasks are a popular input method for controlling brain-computer interfaces (BCIs), partially due to their similarities to naturally produced motor signals. The use of functional near-infrared spectroscopy (fNIRS) in BCIs is still emerging and has shown potential as a supplement or replacement for electroencephalography. However, studies often use only two or three motor-imagery tasks, limiting the number of available commands. In this work, we present the results of the first four-class motor-imagery-based online fNIRS-BCI for robot control. Thirteen participants utilized upper- and lower-limb motor-imagery tasks (left hand, right hand, left foot, and right foot) that were mapped to four high-level commands (turn left, turn right, move forward, and move backward) to control the navigation of a simulated or real robot. A significant improvement in classification accuracy was found between the virtual-robot-based BCI (control of a virtual robot) and the physical-robot BCI (control of the DARwIn-OP humanoid robot). Differences were also found in the oxygenated hemoglobin activation patterns of the four tasks between the first and second BCI. These results corroborate previous findings that motor imagery can be improved with feedback and imply that a four-class motor-imagery-based fNIRS-BCI could be feasible with sufficient subject training. PMID:28804712
Batula, Alyssa M; Kim, Youngmoo E; Ayaz, Hasan
2017-01-01
Motor-imagery tasks are a popular input method for controlling brain-computer interfaces (BCIs), partially due to their similarities to naturally produced motor signals. The use of functional near-infrared spectroscopy (fNIRS) in BCIs is still emerging and has shown potential as a supplement or replacement for electroencephalography. However, studies often use only two or three motor-imagery tasks, limiting the number of available commands. In this work, we present the results of the first four-class motor-imagery-based online fNIRS-BCI for robot control. Thirteen participants utilized upper- and lower-limb motor-imagery tasks (left hand, right hand, left foot, and right foot) that were mapped to four high-level commands (turn left, turn right, move forward, and move backward) to control the navigation of a simulated or real robot. A significant improvement in classification accuracy was found between the virtual-robot-based BCI (control of a virtual robot) and the physical-robot BCI (control of the DARwIn-OP humanoid robot). Differences were also found in the oxygenated hemoglobin activation patterns of the four tasks between the first and second BCI. These results corroborate previous findings that motor imagery can be improved with feedback and imply that a four-class motor-imagery-based fNIRS-BCI could be feasible with sufficient subject training.
Pinter, Daniela; Pegritz, Sandra; Pargfrieder, Christa; Reiter, Gudrun; Wurm, Walter; Gattringer, Thomas; Linderl-Madrutter, Regina; Neuper, Claudia; Fazekas, Franz; Grieshofer, Peter; Enzinger, Christian
2013-01-01
The brain mechanisms underlying successful recovery of hand fuenction after stroke are still not fully understood, although functional MRI (fMRI) studies underline the importance of neuronal plasticity. We explored potential changes in brain activity in 7 patients with subacute to chronic stroke (69 ± 8 years) with moderate- to high-grade distal paresis of the upper limb (Motricity Index: 59.4) after standardized robotic finger-hand rehabilitation training, in addition to conventional rehabilitation therapy for 3 weeks. Behavioral and fMRI assessments were carried out before and after training to characterize changes in brain activity and behavior. The Motricity Index (pre: 59.4, post: 67.2, P < .05) and grip force (pre: 7.26, post: 11.87, P < .05) of the paretic hand increased significantly after rehabilitation. On fMRI, active movement of the affected (left) hand resulted in contralesional (ie, ipsilateral) activation of the primary sensorimotor cortex prior to rehabilitation. After rehabilitation, activation appeared "normalized," including the ipsilesional primary sensorimotor cortex and supplementary motor area (SMA). No changes and no abnormalities of activation maps were seen during movement of the unaffected hand. Subsequent region-of-interest analyses showed no significant ipsilesional activation increases after rehabilitation. Despite behavioral improvements, we failed to identify consistent patterns of functional reorganization in our sample. This warrants caution in the use of fMRI as a tool to explore neural plasticity in heterogeneous samples lacking sufficient statistical power.
Turner, Duncan L.; Ramos-Murguialday, Ander; Birbaumer, Niels; Hoffmann, Ulrich; Luft, Andreas
2013-01-01
The recovery of functional movements following injury to the central nervous system (CNS) is multifaceted and is accompanied by processes occurring in the injured and non-injured hemispheres of the brain or above/below a spinal cord lesion. The changes in the CNS are the consequence of functional and structural processes collectively termed neuroplasticity and these may occur spontaneously and/or be induced by movement practice. The neurophysiological mechanisms underlying such brain plasticity may take different forms in different types of injury, for example stroke vs. spinal cord injury (SCI). Recovery of movement can be enhanced by intensive, repetitive, variable, and rewarding motor practice. To this end, robots that enable or facilitate repetitive movements have been developed to assist recovery and rehabilitation. Here, we suggest that some elements of robot-mediated training such as assistance and perturbation may have the potential to enhance neuroplasticity. Together the elemental components for developing integrated robot-mediated training protocols may form part of a neurorehabilitation framework alongside those methods already employed by therapists. Robots could thus open up a wider choice of options for delivering movement rehabilitation grounded on the principles underpinning neuroplasticity in the human CNS. PMID:24312073
Proctorship and mentoring: Its backbone and application in robotic surgery.
Santok, Glen Denmer; Raheem, Ali Abdel; Kim, Lawrence Hc; Chang, Kidon; Chung, Byung Ha; Choi, Young Deuk; Rha, Koon Ho
2016-12-01
In pursuit of continuing medical education in robotic surgery, several forms of training have been implemented. This variable application of curriculum has brought acquisition of skills in a heterogeneous and unstandardized fashion from different parts of the world. Recently, efforts have been made to provide cost effective and well-structured curricula with the aim of bridging the gap between formal fellowship training and short courses. Proctorship training has been implicated on some curriculum to provide excellent progression during the learning curve while ensuring patient safety.
2010 FIRST Robotics Bayou Regional Tournament
NASA Technical Reports Server (NTRS)
2010-01-01
Student-built robots maneuver the course during the 2010 Bayou Regional FIRST (For Inspiration and Recognition of Science and Technology) Robotics competition in Westwego on March 5-6. The annual competition drew 36 high school teams from eight states. NASA's John C. Stennis Space Center supports FIRST Robotics by providing financing, mentors and training, as well as competition judges and referees, audiovisual staff and other volunteer personnel.
2010 FIRST Robotics Bayou Regional Tournament
2010-03-05
Student-built robots maneuver the course during the 2010 Bayou Regional FIRST (For Inspiration and Recognition of Science and Technology) Robotics competition in Westwego on March 5-6. The annual competition drew 36 high school teams from eight states. NASA's John C. Stennis Space Center supports FIRST Robotics by providing financing, mentors and training, as well as competition judges and referees, audiovisual staff and other volunteer personnel.
Tanabe, Shigeo; Koyama, Soichiro; Saitoh, Eiichi; Hirano, Satoshi; Yatsuya, Kanan; Tsunoda, Tetsuya; Katoh, Masaki; Gotoh, Takeshi; Furumoto, Ayako
2017-01-01
Patients with tetraplegia can achieve independent gait with lateral-type powered exoskeletons; it is unclear whether medial-type powered exoskeletons allow for this. To investigate gait training with a medial-type powered exoskeleton wearable power-assist locomotor (WPAL) in an individual with incomplete cervical (C5) and complete thoracic (T12) spinal cord injury (SCI). The 60-session program was investigated retrospectively using medical records. Upon completion, gait performance was examined using three-dimensional motion analyses and surface electromyography (EMG) of the upper limbs. The subject achieved independent gait with WPAL and a walker in 12 sessions. He continuously extended his right elbow; his left elbow periodically flexed/extended. His pelvic inclination was larger than the trunk inclination during single-leg stance. EMG activity was increased in the left deltoid muscles during ipsilateral foot-contact. The right anterior and medial deltoid muscle EMG activity increased just after foot-off for each leg, as did the right biceps activity. Continuous activity was observed in the left triceps throughout the gait cycle; activity was unclear in the right triceps. These results suggest the importance of upper limb residual motor function, and may be useful in extending the range of clinical applications for robotic gait rehabilitation in patients with SCI.
Kotov and Williams with SSRMS arm training session in Node 1 / Unity module
2007-04-18
ISS014-E-19587 (17 April 2007) --- Cosmonaut Oleg V. Kotov (foreground), Expedition 15 flight engineer representing Russia's Federal Space Agency, and astronaut Sunita L. Williams, flight engineer, participate in a Space Station Remote Manipulator System (SSRMS) training session using the Robotic Onboard Trainer (ROBOT) simulator in the Unity node of the International Space Station.
Massie, Crystal L; Kantak, Shailesh S; Narayanan, Priya; Wittenberg, George F
2015-05-01
The objective was to determine how stimulation timing applied during reaching influenced neuroplasticity related to practice. Older adult participants were studied to increase relevance for stroke rehabilitation and aging. Sixteen participants completed 3 sessions of a reaching intervention with 480 planar robotic movement trials. Sub-threshold, single-pulse transcranial magnetic stimulations (TMS) were delivered during the late reaction time (LRT) period, when muscle activity exceeded a threshold (EMG-triggered), or randomly. Assessments included motor evoked potentials (MEP), amplitude, and direction of supra-threshold TMS-evoked movements and were calculated as change scores from baseline. The direction of TMS-evoked movements significantly changed after reaching practice (p<0.05), but was not significantly different between conditions. Movement amplitude changes were significantly different between conditions (p<0.05), with significant increases following the LRT and random conditions. MEP for elbow extensors and flexors, and the shoulder muscle that opposed the practice movement were significantly different between conditions with positive changes following LRT, negative changes following EMG-triggered, and no changes following the random condition. Motor performance including movement time and peak velocity significantly improved following the training but did not differ between conditions. The responsiveness of the motor cortex to stimulation was affected positively by stimulation during the late motor response period and negatively during the early movement period, when stimulation was combined with robotic reach practice. The sensitivity of the activated motor cortex to additional stimulation is highly dynamic. Copyright © 2015. Published by Elsevier Ireland Ltd.
Surgeon Training in Telerobotic Surgery via a Hardware-in-the-Loop Simulator
Alemzadeh, Homa; Chen, Daniel; Kalbarczyk, Zbigniew; Iyer, Ravishankar K.; Kesavadas, Thenkurussi
2017-01-01
This work presents a software and hardware framework for a telerobotic surgery safety and motor skill training simulator. The aims are at providing trainees a comprehensive simulator for acquiring essential skills to perform telerobotic surgery. Existing commercial robotic surgery simulators lack features for safety training and optimal motion planning, which are critical factors in ensuring patient safety and efficiency in operation. In this work, we propose a hardware-in-the-loop simulator directly introducing these two features. The proposed simulator is built upon the Raven-II™ open source surgical robot, integrated with a physics engine and a safety hazard injection engine. Also, a Fast Marching Tree-based motion planning algorithm is used to help trainee learn the optimal instrument motion patterns. The main contributions of this work are (1) reproducing safety hazards events, related to da Vinci™ system, reported to the FDA MAUDE database, with a novel haptic feedback strategy to provide feedback to the operator when the underlying dynamics differ from the real robot's states so that the operator will be aware and can mitigate the negative impact of the safety-critical events, and (2) using motion planner to generate semioptimal path in an interactive robotic surgery training environment. PMID:29065635
Galvez, Jose A; Budovitch, Amy; Harkema, Susan J; Reinkensmeyer, David J
2011-01-01
Robotic devices are being developed to automate repetitive aspects of walking retraining after neurological injuries, in part because they might improve the consistency and quality of training. However, it is unclear how inconsistent manual training actually is or whether stepping quality depends strongly on the trainers' manual skill. The objective of this study was to quantify trainer variability of manual skill during step training using body-weight support on a treadmill and assess factors of trainer skill. We attached a sensorized orthosis to one leg of each patient with spinal cord injury and measured the shank kinematics and forces exerted by different trainers during six training sessions. An expert trainer rated the trainers' skill level based on videotape recordings. Between-trainer force variability was substantial, about two times greater than within-trainer variability. Trainer skill rating correlated strongly with two gait features: better knee extension during stance and fewer episodes of toe dragging. Better knee extension correlated directly with larger knee horizontal assistance force, but better toe clearance did not correlate with larger ankle push-up force; rather, it correlated with better knee and hip extension. These results are useful to inform robotic gait-training design.
Getting started with robotics in general surgery with cholecystectomy: the Canadian experience.
Jayaraman, Shiva; Davies, Ward; Schlachta, Christopher M
2009-10-01
The value of robotics in general surgery may be for advanced minimally invasive procedures. Unlike other specialties, formal fellowship training opportunities for robotic general surgery are few. As a result, most surgeons currently develop robotic skills in practice. Our goal was to determine whether robotic cholecystectomy is a safe and effective bridge to advanced robotics in general surgery. Before performing advanced robotic procedures, 2 surgeons completed the Intuitive Surgical da Vinci training course and agreed to work together on all procedures. Clinical surgery began with da Vinci cholecystectomy with a plan to begin advanced procedures after at least 10 cholecystectomies. We performed a retrospective review of our pilot series of robotic cholecystectomies and compared them with contemporaneous laparoscopic controls. The primary outcome was safety, and the secondary outcome was learning curve. There were 16 procedures in the robotics arm and 20 in the laparoscopic arm. Two complications (da Vinci port-site hernia, transient elevation of liver enzymes) occurred in the robotic arm, whereas only 1 laparoscopic patient (slow to awaken from anesthetic) experienced a complication. None was significant. The mean time required to perform robotic cholecystectomy was significantly longer than laparoscopic surgery (91 v. 41 min, p < 0.001). The mean time to clear the operating room was significantly longer for robotic procedures (14 v. 11 min, p = 0.015). We observed a trend showing longer mean anesthesia time for robotic procedures (23 v. 15 min). Regarding learning curve, the mean operative time needed for the first 3 robotic procedures was longer than for the last 3 (101 v. 80 min); however, this difference was not significant. Since this experience, the team has confidently gone on to perform robotic biliary, pancreatic, gastresophageal, intestinal and colorectal operations. Robotic cholecystectomy can be performed reliably; however, owing to the significant increase in operating room resources, it cannot be justified for routine use. Our experience, however, demonstrates that robotic cholecystectomy is one means by which general surgeons may gain confidence in performing advanced robotic procedures.
Perioperative nurse training in cardiothoracic surgical robotics.
Connor, M A; Reinbolt, J A; Handley, P J
2001-12-01
The exponential growth of OR technology during the past 10 years has placed increased demands on perioperative nurses. Proficiency is required not only in patient care but also in the understanding, operating, and troubleshooting of video systems, computers, and cutting edge medical devices. The formation of a surgical team dedicated to robotically assisted cardiac surgery requires careful selection, education, and hands-on practice. This article details the six-week training process undertaken at Sarasota Memorial Hospital, Sarasota, Fla, which enabled staff members to deliver excellent patient care with a high degree of confidence in themselves and the robotic technology.
Sood, Akshay; Ghani, Khurshid R; Ahlawat, Rajesh; Modi, Pranjal; Abaza, Ronney; Jeong, Wooju; Sammon, Jesse D; Diaz, Mireya; Kher, Vijay; Menon, Mani; Bhandari, Mahendra
2014-08-01
Traditional evaluation of the learning curve (LC) of an operation has been retrospective. Furthermore, LC analysis does not permit patient safety monitoring. To prospectively monitor patient safety during the learning phase of robotic kidney transplantation (RKT) and determine when it could be considered learned using the techniques of statistical process control (SPC). From January through May 2013, 41 patients with end-stage renal disease underwent RKT with regional hypothermia at one of two tertiary referral centers adopting RKT. Transplant recipients were classified into three groups based on the robotic training and kidney transplant experience of the surgeons: group 1, robot trained with limited kidney transplant experience (n=7); group 2, robot trained and kidney transplant experienced (n=20); and group 3, kidney transplant experienced with limited robot training (n=14). We employed prospective monitoring using SPC techniques, including cumulative summation (CUSUM) and Shewhart control charts, to perform LC analysis and patient safety monitoring, respectively. Outcomes assessed included post-transplant graft function and measures of surgical process (anastomotic and ischemic times). CUSUM and Shewhart control charts are time trend analytic techniques that allow comparative assessment of outcomes following a new intervention (RKT) relative to those achieved with established techniques (open kidney transplant; target value) in a prospective fashion. CUSUM analysis revealed an initial learning phase for group 3, whereas groups 1 and 2 had no to minimal learning time. The learning phase for group 3 varied depending on the parameter assessed. Shewhart control charts demonstrated no compromise in functional outcomes for groups 1 and 2. Graft function was compromised in one patient in group 3 (p<0.05) secondary to reasons unrelated to RKT. In multivariable analysis, robot training was significantly associated with improved task-completion times (p<0.01). Graft function was not adversely affected by either the lack of robotic training (p=0.22) or kidney transplant experience (p=0.72). The LC and patient safety of a new surgical technique can be assessed prospectively using CUSUM and Shewhart control chart analytic techniques. These methods allow determination of the duration of mentorship and identification of adverse events in a timely manner. A new operation can be considered learned when outcomes achieved with the new intervention are at par with outcomes following established techniques. Statistical process control techniques allowed for robust, objective, and prospective monitoring of robotic kidney transplantation and can similarly be applied to other new interventions during the introduction and adoption phase. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Sornkarn, Nantachai; Nanayakkara, Thrishantha
2017-01-01
When humans are asked to palpate a soft tissue to locate a hard nodule, they regulate the stiffness, speed, and force of the finger during examination. If we understand the relationship between these behavioral variables and haptic information gain (transfer entropy) during manual probing, we can improve the efficacy of soft robotic probes for soft tissue palpation, such as in tumor localization in minimally invasive surgery. Here, we recorded the muscle co-contraction activity of the finger using EMG sensors to address the question as to whether joint stiffness control during manual palpation plays an important role in the haptic information gain. To address this question, we used a soft robotic probe with a controllable stiffness joint and a force sensor mounted at the base to represent the function of the tendon in a biological finger. Then, we trained a Markov chain using muscle co-contraction patterns of human subjects, and used it to control the stiffness of the soft robotic probe in the same soft tissue palpation task. The soft robotic experiments showed that haptic information gain about the depth of the hard nodule can be maximized by varying the internal stiffness of the soft probe.
Brain-Machine Interface control of a robot arm using actor-critic rainforcement learning.
Pohlmeyer, Eric A; Mahmoudi, Babak; Geng, Shijia; Prins, Noeline; Sanchez, Justin C
2012-01-01
Here we demonstrate how a marmoset monkey can use a reinforcement learning (RL) Brain-Machine Interface (BMI) to effectively control the movements of a robot arm for a reaching task. In this work, an actor-critic RL algorithm used neural ensemble activity in the monkey's motor cortext to control the robot movements during a two-target decision task. This novel approach to decoding offers unique advantages for BMI control applications. Compared to supervised learning decoding methods, the actor-critic RL algorithm does not require an explicit set of training data to create a static control model, but rather it incrementally adapts the model parameters according to its current performance, in this case requiring only a very basic feedback signal. We show how this algorithm achieved high performance when mapping the monkey's neural states (94%) to robot actions, and only needed to experience a few trials before obtaining accurate real-time control of the robot arm. Since RL methods responsively adapt and adjust their parameters, they can provide a method to create BMIs that are robust against perturbations caused by changes in either the neural input space or the output actions they generate under different task requirements or goals.
Ahmed, Kamran; Khan, Reenam; Mottrie, Alexandre; Lovegrove, Catherine; Abaza, Ronny; Ahlawat, Rajesh; Ahlering, Thomas; Ahlgren, Goran; Artibani, Walter; Barret, Eric; Cathelineau, Xavier; Challacombe, Ben; Coloby, Patrick; Khan, Muhammad S; Hubert, Jacques; Michel, Maurice Stephan; Montorsi, Francesco; Murphy, Declan; Palou, Joan; Patel, Vipul; Piechaud, Pierre-Thierry; Van Poppel, Hendrik; Rischmann, Pascal; Sanchez-Salas, Rafael; Siemer, Stefan; Stoeckle, Michael; Stolzenburg, Jens-Uwe; Terrier, Jean-Etienne; Thüroff, Joachim W; Vaessen, Christophe; Van Der Poel, Henk G; Van Cleynenbreugel, Ben; Volpe, Alessandro; Wagner, Christian; Wiklund, Peter; Wilson, Timothy; Wirth, Manfred; Witt, Jörn; Dasgupta, Prokar
2015-07-01
To explore the views of experts about the development and validation of a robotic surgery training curriculum, and how this should be implemented. An international expert panel was invited to a structured session for discussion. The study was of a mixed design, including qualitative and quantitative components based on focus group interviews during the European Association of Urology (EAU) Robotic Urology Section (ERUS) (2012), EAU (2013) and ERUS (2013) meetings. After introduction to the aims, principles and current status of the curriculum development, group responses were elicited. After content analysis of recorded interviews generated themes were discussed at the second meeting, where consensus was achieved on each theme. This discussion also underwent content analysis, and was used to draft a curriculum proposal. At the third meeting, a quantitative questionnaire about this curriculum was disseminated to attendees to assess the level of agreement with the key points. In all, 150 min (19 pages) of the focus group discussion was transcribed (21 316 words). Themes were agreed by two raters (median agreement κ 0.89) and they included: need for a training curriculum (inter-rater agreement κ 0.85); identification of learning needs (κ 0.83); development of the curriculum contents (κ 0.81); an overview of available curricula (κ 0.79); settings for robotic surgery training ((κ 0.89); assessment and training of trainers (κ 0.92); requirements for certification and patient safety (κ 0.83); and need for a universally standardised curriculum (κ 0.78). A training curriculum was proposed based on the above discussions. This group proposes a multi-step curriculum for robotic training. Studies are in process to validate the effectiveness of the curriculum and to assess transfer of skills to the operating room. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.
Cortical Spiking Network Interfaced with Virtual Musculoskeletal Arm and Robotic Arm.
Dura-Bernal, Salvador; Zhou, Xianlian; Neymotin, Samuel A; Przekwas, Andrzej; Francis, Joseph T; Lytton, William W
2015-01-01
Embedding computational models in the physical world is a critical step towards constraining their behavior and building practical applications. Here we aim to drive a realistic musculoskeletal arm model using a biomimetic cortical spiking model, and make a robot arm reproduce the same trajectories in real time. Our cortical model consisted of a 3-layered cortex, composed of several hundred spiking model-neurons, which display physiologically realistic dynamics. We interconnected the cortical model to a two-joint musculoskeletal model of a human arm, with realistic anatomical and biomechanical properties. The virtual arm received muscle excitations from the neuronal model, and fed back proprioceptive information, forming a closed-loop system. The cortical model was trained using spike timing-dependent reinforcement learning to drive the virtual arm in a 2D reaching task. Limb position was used to simultaneously control a robot arm using an improved network interface. Virtual arm muscle activations responded to motoneuron firing rates, with virtual arm muscles lengths encoded via population coding in the proprioceptive population. After training, the virtual arm performed reaching movements which were smoother and more realistic than those obtained using a simplistic arm model. This system provided access to both spiking network properties and to arm biophysical properties, including muscle forces. The use of a musculoskeletal virtual arm and the improved control system allowed the robot arm to perform movements which were smoother than those reported in our previous paper using a simplistic arm. This work provides a novel approach consisting of bidirectionally connecting a cortical model to a realistic virtual arm, and using the system output to drive a robotic arm in real time. Our techniques are applicable to the future development of brain neuroprosthetic control systems, and may enable enhanced brain-machine interfaces with the possibility for finer control of limb prosthetics.
Development and training of a learning expert system in an autonomous mobile robot via simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spelt, P.F.; Lyness, E.; DeSaussure, G.
1989-11-01
The Center for Engineering Systems Advanced Research (CESAR) conducts basic research in the area of intelligent machines. Recently at CESAR a learning expert system was created to operate on board an autonomous robot working at a process control panel. The authors discuss two-computer simulation system used to create, evaluate and train this learning system. The simulation system has a graphics display of the current status of the process being simulated, and the same program which does the simulating also drives the actual control panel. Simulation results were validated on the actual robot. The speed and safety values of using amore » computerized simulator to train a learning computer, and future uses of the simulation system, are discussed.« less
[Walking assist robot and its clinical application].
Kakou, Hiroaki; Shitama, Hideo; Kimura, Yoshiko; Nakamoto, Yoko; Furuta, Nami; Honda, Kanae; Wada, Futoshi; Hachisuka, Kenji
2009-06-01
The walking assist robot was developed to improve gait disturbance in patients with severe disabilities. The robot had a trunk supporter, power generator and operating arms which held patient's lower extremities and simulated walking, a control unit, biofeedback system, and a treadmill. We applied the robot-aided gait training to three patients with severe gait disturbance induced by stroke, axonal Guillan-Barré syndrome or spinal cord injury, and the walking assist robot turned out to be effective in improving the gait disturbance.
Rodgers, Helen; Shaw, Lisa; Bosomworth, Helen; Aird, Lydia; Alvarado, Natasha; Andole, Sreeman; Cohen, David L; Dawson, Jesse; Eyre, Janet; Finch, Tracy; Ford, Gary A; Hislop, Jennifer; Hogg, Steven; Howel, Denise; Hughes, Niall; Krebs, Hermano Igo; Price, Christopher; Rochester, Lynn; Stamp, Elaine; Ternent, Laura; Turner, Duncan; Vale, Luke; Warburton, Elizabeth; van Wijck, Frederike; Wilkes, Scott
2017-07-20
Loss of arm function is a common and distressing consequence of stroke. We describe the protocol for a pragmatic, multicentre randomised controlled trial to determine whether robot-assisted training improves upper limb function following stroke. Study design: a pragmatic, three-arm, multicentre randomised controlled trial, economic analysis and process evaluation. NHS stroke services. adults with acute or chronic first-ever stroke (1 week to 5 years post stroke) causing moderate to severe upper limb functional limitation. Randomisation groups: 1. Robot-assisted training using the InMotion robotic gym system for 45 min, three times/week for 12 weeks 2. Enhanced upper limb therapy for 45 min, three times/week for 12 weeks 3. Usual NHS care in accordance with local clinical practice Randomisation: individual participant randomisation stratified by centre, time since stroke, and severity of upper limb impairment. upper limb function measured by the Action Research Arm Test (ARAT) at 3 months post randomisation. upper limb impairment (Fugl-Meyer Test), activities of daily living (Barthel ADL Index), quality of life (Stroke Impact Scale, EQ-5D-5L), resource use, cost per quality-adjusted life year and adverse events, at 3 and 6 months. Blinding: outcomes are undertaken by blinded assessors. Economic analysis: micro-costing and economic evaluation of interventions compared to usual NHS care. A within-trial analysis, with an economic model will be used to extrapolate longer-term costs and outcomes. Process evaluation: semi-structured interviews with participants and professionals to seek their views and experiences of the rehabilitation that they have received or provided, and factors affecting the implementation of the trial. allowing for 10% attrition, 720 participants provide 80% power to detect a 15% difference in successful outcome between each of the treatment pairs. Successful outcome definition: baseline ARAT 0-7 must improve by 3 or more points; baseline ARAT 8-13 improve by 4 or more points; baseline ARAT 14-19 improve by 5 or more points; baseline ARAT 20-39 improve by 6 or more points. The results from this trial will determine whether robot-assisted training improves upper limb function post stroke. ISRCTN, identifier: ISRCTN69371850 . Registered 4 October 2013.
Li, Yongcheng; Sun, Rong; Wang, Yuechao; Li, Hongyi; Zheng, Xiongfei
2016-01-01
We propose the architecture of a novel robot system merging biological and artificial intelligence based on a neural controller connected to an external agent. We initially built a framework that connected the dissociated neural network to a mobile robot system to implement a realistic vehicle. The mobile robot system characterized by a camera and two-wheeled robot was designed to execute the target-searching task. We modified a software architecture and developed a home-made stimulation generator to build a bi-directional connection between the biological and the artificial components via simple binomial coding/decoding schemes. In this paper, we utilized a specific hierarchical dissociated neural network for the first time as the neural controller. Based on our work, neural cultures were successfully employed to control an artificial agent resulting in high performance. Surprisingly, under the tetanus stimulus training, the robot performed better and better with the increasement of training cycle because of the short-term plasticity of neural network (a kind of reinforced learning). Comparing to the work previously reported, we adopted an effective experimental proposal (i.e. increasing the training cycle) to make sure of the occurrence of the short-term plasticity, and preliminarily demonstrated that the improvement of the robot's performance could be caused independently by the plasticity development of dissociated neural network. This new framework may provide some possible solutions for the learning abilities of intelligent robots by the engineering application of the plasticity processing of neural networks, also for the development of theoretical inspiration for the next generation neuro-prostheses on the basis of the bi-directional exchange of information within the hierarchical neural networks.
Gagnon, Dany H; Escalona, Manuel J; Vermette, Martin; Carvalho, Lívia P; Karelis, Antony D; Duclos, Cyril; Aubertin-Leheudre, Mylène
2018-03-01
For individuals who sustain a complete motor spinal cord injury (SCI) and rely on a wheelchair as their primary mode of locomotion, overground robotic exoskeletons represent a promising solution to stand and walk again. Although overground robotic exoskeletons have gained tremendous attention over the past decade and are now being transferred from laboratories to clinical settings, their effects remain unclear given the paucity of scientific evidence and the absence of large-scale clinical trials. This study aims to examine the feasibility of a locomotor training program with an overground robotic exoskeleton in terms of recruitment, attendance, and drop-out rates as well as walking performance, learnability, and safety. Individuals with a SCI were invited to participate in a 6 to 8-week locomotor training program with a robotic exoskeleton encompassing 18 sessions. Selected participants underwent a comprehensive screening process and completed two familiarization sessions with the robotic exoskeleton. The outcome measures were the rate of recruitment of potential participants, the rate of attendance at training sessions, the rate of drop-outs, the ability to walk with the exoskeleton, and its progression over the program as well as the adverse events. Out of 49 individuals who expressed their interest in participating in the study, only 14 initiated the program (recruitment rate = 28.6%). Of these, 13 individuals completed the program (drop-out rate = 7.1%) and attended 17.6 ± 1.1 sessions (attendance rate = 97.9%). Their greatest standing time, walking time, and number of steps taken during a session were 64.5 ± 10.2 min, 47.2 ± 11.3 min, and 1843 ± 577 steps, respectively. During the training program, these last three parameters increased by 45.3%, 102.1%, and 248.7%, respectively. At the end of the program, when walking with the exoskeleton, most participants required one therapist (85.7%), needed stand-by or contact-guard assistance (57.1%), used forearm crutches (71.4%), and reached a walking speed of 0.25 ± 0.05 m/s. Five participants reported training-related pain or stiffness in the upper extremities during the program. One participant sustained bilateral calcaneal fractures and stopped the program. This study confirms that larger clinical trials investigating the effects of a locomotor training program with an overground robotic exoskeleton are feasible and relatively safe in individuals with complete motor SCI. Moreover, to optimize the recruitment rate and safety in future trials, this study now highlights the need of developing pre-training rehabilitation programs to increase passive lower extremity range of motion and standing tolerance. This study also calls for the development of clinical practice guidelines targeting fragility fracture risk assessment linked to the use of overground robotic exoskeletons.
sEMG-based joint force control for an upper-limb power-assist exoskeleton robot.
Li, Zhijun; Wang, Baocheng; Sun, Fuchun; Yang, Chenguang; Xie, Qing; Zhang, Weidong
2014-05-01
This paper investigates two surface electromyogram (sEMG)-based control strategies developed for a power-assist exoskeleton arm. Different from most of the existing position control approaches, this paper develops force control methods to make the exoskeleton robot behave like humans in order to provide better assistance. The exoskeleton robot is directly attached to a user's body and activated by the sEMG signals of the user's muscles, which reflect the user's motion intention. In the first proposed control method, the forces of agonist and antagonist muscles pair are estimated, and their difference is used to produce the torque of the corresponding joints. In the second method, linear discriminant analysis-based classifiers are introduced as the indicator of the motion type of the joints. Then, the classifier's outputs together with the estimated force of corresponding active muscle determine the torque control signals. Different from the conventional approaches, one classifier is assigned to each joint, which decreases the training time and largely simplifies the recognition process. Finally, the extensive experiments are conducted to illustrate the effectiveness of the proposed approaches.
Wireless Cortical Brain-Machine Interface for Whole-Body Navigation in Primates
NASA Astrophysics Data System (ADS)
Rajangam, Sankaranarayani; Tseng, Po-He; Yin, Allen; Lehew, Gary; Schwarz, David; Lebedev, Mikhail A.; Nicolelis, Miguel A. L.
2016-03-01
Several groups have developed brain-machine-interfaces (BMIs) that allow primates to use cortical activity to control artificial limbs. Yet, it remains unknown whether cortical ensembles could represent the kinematics of whole-body navigation and be used to operate a BMI that moves a wheelchair continuously in space. Here we show that rhesus monkeys can learn to navigate a robotic wheelchair, using their cortical activity as the main control signal. Two monkeys were chronically implanted with multichannel microelectrode arrays that allowed wireless recordings from ensembles of premotor and sensorimotor cortical neurons. Initially, while monkeys remained seated in the robotic wheelchair, passive navigation was employed to train a linear decoder to extract 2D wheelchair kinematics from cortical activity. Next, monkeys employed the wireless BMI to translate their cortical activity into the robotic wheelchair’s translational and rotational velocities. Over time, monkeys improved their ability to navigate the wheelchair toward the location of a grape reward. The navigation was enacted by populations of cortical neurons tuned to whole-body displacement. During practice with the apparatus, we also noticed the presence of a cortical representation of the distance to reward location. These results demonstrate that intracranial BMIs could restore whole-body mobility to severely paralyzed patients in the future.
Needs for Robotic Assessments of Nuclear Disasters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Victor Walker; Derek Wadsworth
Following the nuclear disaster at the Fukushima nuclear reactor plant in Japan, the need for systems which can assist in dynamic high-radiation environments such as nuclear incidents has become more apparent. The INL participated in delivering robotic technologies to Japan and has identified key components which are needed for success and obstacles to their deployment. In addition, we are proposing new work and methods to improve assessments and reactions to such events in the future. Robotics needs in disaster situations include phases such as: Assessment, Remediation, and Recovery Our particular interest is in the initial assessment activities. In assessment wemore » need collection of environmental parameters, determination of conditions, and physical sample collection. Each phase would require key tools and efforts to develop. This includes study of necessary sensors and their deployment methods, the effects of radiation on sensors and deployment, and the development of training and execution systems.« less
Rehabilitation robots for the treatment of sensorimotor deficits: a neurophysiological perspective.
Gassert, Roger; Dietz, Volker
2018-06-05
The past decades have seen rapid and vast developments of robots for the rehabilitation of sensorimotor deficits after damage to the central nervous system (CNS). Many of these innovations were technology-driven, limiting their clinical application and impact. Yet, rehabilitation robots should be designed on the basis of neurophysiological insights underlying normal and impaired sensorimotor functions, which requires interdisciplinary collaboration and background knowledge.Recovery of sensorimotor function after CNS damage is based on the exploitation of neuroplasticity, with a focus on the rehabilitation of movements needed for self-independence. This requires a physiological limb muscle activation that can be achieved through functional arm/hand and leg movement exercises and the activation of appropriate peripheral receptors. Such considerations have already led to the development of innovative rehabilitation robots with advanced interaction control schemes and the use of integrated sensors to continuously monitor and adapt the support to the actual state of patients, but many challenges remain. For a positive impact on outcome of function, rehabilitation approaches should be based on neurophysiological and clinical insights, keeping in mind that recovery of function is limited. Consequently, the design of rehabilitation robots requires a combination of specialized engineering and neurophysiological knowledge. When appropriately applied, robot-assisted therapy can provide a number of advantages over conventional approaches, including a standardized training environment, adaptable support and the ability to increase therapy intensity and dose, while reducing the physical burden on therapists. Rehabilitation robots are thus an ideal means to complement conventional therapy in the clinic, and bear great potential for continued therapy and assistance at home using simpler devices.This review summarizes the evolution of the field of rehabilitation robotics, as well as the current state of clinical evidence. It highlights fundamental neurophysiological factors influencing the recovery of sensorimotor function after a stroke or spinal cord injury, and discusses their implications for the development of effective rehabilitation robots. It thus provides insights on essential neurophysiological mechanisms to be considered for a successful development and clinical inclusion of robots in rehabilitation.
Comparative analysis of the functionality of simulators of the da Vinci surgical robot.
Smith, Roger; Truong, Mireille; Perez, Manuela
2015-04-01
The implementation of robotic technology in minimally invasive surgery has led to the need to develop more efficient and effective training methods, as well as assessment and skill maintenance tools for surgical education. Multiple simulators and procedures are available for educational and training purposes. A need for comparative evaluations of these simulators exists to aid users in selecting an appropriate device for their purposes. We conducted an objective review and comparison of the design and capabilities of all dedicated simulators of the da Vinci robot, the da Vinci Skill Simulator (DVSS) (Intuitive Surgical Inc., Sunnyvale, CA, USA), dV-Trainer (dVT) (Mimic Technologies Inc., Seattle, WA, USA), and Robotic Surgery Simulator (RoSS) (Simulated Surgical Skills, LLC, Williamsville, NY, USA). This provides base specifications of the hardware and software, with an emphasis on the training capabilities of each system. Each simulator contains a large number of training exercises, DVSS = 40, dVT = 65, and RoSS = 52 for skills development. All three offer 3D visual images but use different display technologies. The DVSS leverages the real robotic surgeon's console to provide visualization, hand controls, and foot pedals. The dVT and RoSS created simulated versions of all of these control systems. They include systems management services which allow instructors to collect, export, and analyze the scores of students using the simulators. This study is the first to provide comparative information of the three simulators functional capabilities with an emphasis on their educational skills. They offer unique advantages and capabilities in training robotic surgeons. Each device has been the subject of multiple validation experiments which have been published in the literature. But those do not provide specific details on the capabilities of the simulators which are necessary for an understanding sufficient to select the one best suited for an organization's needs.
Gandolfi, Marialuisa; Geroin, Christian; Picelli, Alessandro; Munari, Daniele; Waldner, Andreas; Tamburin, Stefano; Marchioretto, Fabio; Smania, Nicola
2014-01-01
Background: Extensive research on both healthy subjects and patients with central nervous damage has elucidated a crucial role of postural adjustment reactions and central sensory integration processes in generating and “shaping” locomotor function, respectively. Whether robotic-assisted gait devices might improve these functions in Multiple sclerosis (MS) patients is not fully investigated in literature. Purpose: The aim of this study was to compare the effectiveness of end-effector robot-assisted gait training (RAGT) and sensory integration balance training (SIBT) in improving walking and balance performance in patients with MS. Methods: Twenty-two patients with MS (EDSS: 1.5–6.5) were randomly assigned to two groups. The RAGT group (n = 12) underwent end-effector system training. The SIBT group (n = 10) underwent specific balance exercises. Each patient received twelve 50-min treatment sessions (2 days/week). A blinded rater evaluated patients before and after treatment as well as 1 month post treatment. Primary outcomes were walking speed and Berg Balance Scale. Secondary outcomes were the Activities-specific Balance Confidence Scale, Sensory Organization Balance Test, Stabilometric Assessment, Fatigue Severity Scale, cadence, step length, single and double support time, Multiple Sclerosis Quality of Life-54. Results: Between groups comparisons showed no significant differences on primary and secondary outcome measures over time. Within group comparisons showed significant improvements in both groups on the Berg Balance Scale (P = 0.001). Changes approaching significance were found on gait speed (P = 0.07) only in the RAGT group. Significant changes in balance task-related domains during standing and walking conditions were found in the SIBT group. Conclusion: Balance disorders in patients with MS may be ameliorated by RAGT and by SIBT. PMID:24904361
Direct manipulation of tool-like masters for controlling a master-slave surgical robotic system.
Zhang, Linan; Zhou, Ningxin; Wang, Shuxin
2014-12-01
Robotic-assisted minimally invasive surgery (MIS) can benefit both patients and surgeons. However, the learning curve for robotically assisted procedures can be long and the total system costs are high. Therefore, there is considerable interest in new methods and lower cost controllers for a surgical robotic system. In this study, a knife-master and a forceps-master, shaped similarly to a surgical knife and forceps, were developed as input devices for control of a master-slave surgical robotic system. In addition, a safety strategy was developed to eliminate the master-slave orientation difference and stabilize the surgical system. Master-slave tracking experiments and a ring-and-bar experiment showed that the safety tracking strategy could ensure that the robot system moved stably without any tremor in the tracking motion. Subjects could manipulate the surgical tool to achieve the master-slave operation with less training compared to a mechanical master. Direct manipulation of the small, light and low-cost surgical tools to control a robotic system is a possible operating mode. Surgeons can operate the robotic system in their own familiar way, without long training. The main potential safety issues can be solved by the proposed safety control strategy. Copyright © 2013 John Wiley & Sons, Ltd.
Allothetic and idiothetic sensor fusion in rat-inspired robot localization
NASA Astrophysics Data System (ADS)
Weitzenfeld, Alfredo; Fellous, Jean-Marc; Barrera, Alejandra; Tejera, Gonzalo
2012-06-01
We describe a spatial cognition model based on the rat's brain neurophysiology as a basis for new robotic navigation architectures. The model integrates allothetic (external visual landmarks) and idiothetic (internal kinesthetic information) cues to train either rat or robot to learn a path enabling it to reach a goal from multiple starting positions. It stands in contrast to most robotic architectures based on SLAM, where a map of the environment is built to provide probabilistic localization information computed from robot odometry and landmark perception. Allothetic cues suffer in general from perceptual ambiguity when trying to distinguish between places with equivalent visual patterns, while idiothetic cues suffer from imprecise motions and limited memory recalls. We experiment with both types of cues in different maze configurations by training rats and robots to find the goal starting from a fixed location, and then testing them to reach the same target from new starting locations. We show that the robot, after having pre-explored a maze, can find a goal with improved efficiency, and is able to (1) learn the correct route to reach the goal, (2) recognize places already visited, and (3) exploit allothetic and idiothetic cues to improve on its performance. We finally contrast our biologically-inspired approach to more traditional robotic approaches and discuss current work in progress.
Walliczek-Dworschak, U; Schmitt, M; Dworschak, P; Diogo, I; Ecke, A; Mandapathil, M; Teymoortash, A; Güldner, C
2017-06-01
Increasing usage of robotic surgery presents surgeons with the question of how to acquire the special skills required. This study aimed to analyze the effect of different exercises on their performance outcomes. This prospective study was conducted on the da Vinci Skills Simulator from December 2014 till August 2015. Sixty robotic novices were included and randomized to three groups of 20 participants each. Each group performed three different exercises with comparable difficulty levels. The exercises were performed three times in a row within two training sessions, with an interval of 1 week in between. On the final training day, two new exercises were added and a questionnaire was completed. Technical metrics of performance (overall score, time to complete, economy of motion, instrument collisions, excessive instrument force, instruments out of view, master work space range, drops, missed targets, misapplied energy time, blood loss and broken vessels) were recorded by the simulator software for further analysis. Training with different exercises led to comparable results in performance metrics for the final exercises among the three groups. A significant skills gain was recorded between the first and last exercises, with improved performance in overall score, time to complete and economy of motion for all exercises in all three groups. As training with different exercises led to comparable results in robotic training, the type of exercise seems to play a minor role in the outcome. For a robotic training curriculum, it might be important to choose exercises with comparable difficulty levels. In addition, it seems to be advantageous to limit the duration of the training to maintain the concentration throughout the entire session.
Robot-supported assessment of balance in standing and walking.
Shirota, Camila; van Asseldonk, Edwin; Matjačić, Zlatko; Vallery, Heike; Barralon, Pierre; Maggioni, Serena; Buurke, Jaap H; Veneman, Jan F
2017-08-14
Clinically useful and efficient assessment of balance during standing and walking is especially challenging in patients with neurological disorders. However, rehabilitation robots could facilitate assessment procedures and improve their clinical value. We present a short overview of balance assessment in clinical practice and in posturography. Based on this overview, we evaluate the potential use of robotic tools for such assessment. The novelty and assumed main benefits of using robots for assessment are their ability to assess 'severely affected' patients by providing assistance-as-needed, as well as to provide consistent perturbations during standing and walking while measuring the patient's reactions. We provide a classification of robotic devices on three aspects relevant to their potential application for balance assessment: 1) how the device interacts with the body, 2) in what sense the device is mobile, and 3) on what surface the person stands or walks when using the device. As examples, nine types of robotic devices are described, classified and evaluated for their suitability for balance assessment. Two example cases of robotic assessments based on perturbations during walking are presented. We conclude that robotic devices are promising and can become useful and relevant tools for assessment of balance in patients with neurological disorders, both in research and in clinical use. Robotic assessment holds the promise to provide increasingly detailed assessment that allows to individually tailor rehabilitation training, which may eventually improve training effectiveness.
Scott, William; York, Henry; Theyagaraj, Melita; Price-Miller, Naomi; McQuaid, Jean; Eyvazzadeh, Megan; Ivey, Frederick M.; Macko, Richard F.
2016-01-01
Objective To assess the effectiveness of robotically assisted body weight supported treadmill training (RABWSTT) for improving cardiovascular fitness in chronic motor incomplete spinal cord injury (CMISCI). Design Pilot prospective randomized, controlled clinical trial. Setting Outpatient rehabilitation specialty hospital. Participants Eighteen individuals with CMISCI with American Spinal Injury Association (ASIA) level between C4 and L2 and at least one-year post injury. Interventions CMISCI participants were randomized to RABWSTT or a home stretching program (HSP) three times per week for three months. Those in the home stretching group were crossed over to three months of RABWSTT following completion of the initial three month phase. Outcome measures Peak oxygen consumption (peak VO2) was measured during both robotic treadmill walking and arm cycle ergometry: twice at baseline, once at six weeks (mid-training) and twice at three months (post-training). Peak VO2 values were normalized for body mass. Results The RABWSTT group improved peak VO2 by 12.3% during robotic treadmill walking (20.2 ± 7.4 to 22.7 ± 7.5 ml/kg/min, P = 0.018), compared to a non-significant 3.9% within group change observed in HSP controls (P = 0.37). Neither group displayed a significant change in peak VO2 during arm cycle ergometry (RABWSTT, 8.5% (P = 0.25); HSP, 1.76% (P = 0.72)). A repeated measures analysis showed statistically significant differences between treatments for peak VO2 during both robotic treadmill walking (P = 0.002) and arm cycle ergometry (P = 0.001). Conclusion RABWSTT is an effective intervention model for improving peak fitness levels assessed during robotic treadmill walking in persons with CMISCI. PMID:25520035
2009-01-01
Background Robot-assisted therapy offers a promising approach to neurorehabilitation, particularly for severely to moderately impaired stroke patients. The objective of this study was to investigate the effects of intensive arm training on motor performance in four chronic stroke patients using the robot ARMin II. Methods ARMin II is an exoskeleton robot with six degrees of freedom (DOF) moving shoulder, elbow and wrist joints. Four volunteers with chronic (≥ 12 months post-stroke) left side hemi-paresis and different levels of motor severity were enrolled in the study. They received robot-assisted therapy over a period of eight weeks, three to four therapy sessions per week, each session of one hour. Patients 1 and 4 had four one-hour training sessions per week and patients 2 and 3 had three one-hour training sessions per week. Primary outcome variable was the Fugl-Meyer Score of the upper extremity Assessment (FMA), secondary outcomes were the Wolf Motor Function Test (WMFT), the Catherine Bergego Scale (CBS), the Maximal Voluntary Torques (MVTs) and a questionnaire about ADL-tasks, progress, changes, motivation etc. Results Three out of four patients showed significant improvements (p < 0.05) in the main outcome. The improvements in the FMA scores were aligned with the objective results of MVTs. Most improvements were maintained or even increased from discharge to the six-month follow-up. Conclusion Data clearly indicate that intensive arm therapy with the robot ARMin II can significantly improve motor function of the paretic arm in some stroke patients, even those in a chronic state. The findings of the study provide a basis for a subsequent controlled randomized clinical trial. PMID:20017939
Picelli, Alessandro; Chemello, Elena; Castellazzi, Paola; Filippetti, Mirko; Brugnera, Annalisa; Gandolfi, Marialuisa; Waldner, Andreas; Saltuari, Leopold; Smania, Nicola
2018-01-01
Preliminary evidence showed additional effects of anodal transcranial direct current stimulation over the damaged cerebral hemisphere combined with cathodal transcutaneous spinal direct current stimulation during robot-assisted gait training in chronic stroke patients. This is consistent with the neural organization of locomotion involving cortical and spinal control. The cerebellum is crucial for locomotor control, in particular for avoidance of obstacles, and adaptation to novel conditions during walking. Despite its key role in gait control, to date the effects of transcranial direct current stimulation of the cerebellum have not been investigated on brain stroke patients treated with robot-assisted gait training. To evaluate the effects of cerebellar transcranial direct current stimulation combined with transcutaneous spinal direct current stimulation on robot-assisted gait training in patients with chronic brain stroke. After balanced randomization, 20 chronic stroke patients received ten, 20-minute robot-assisted gait training sessions (five days a week, for two consecutive weeks) combined with central nervous system stimulation. Group 1 underwent on-line cathodal transcranial direct current stimulation over the contralesional cerebellar hemisphere + cathodal transcutaneous spinal direct current stimulation. Group 2 received on-line anodal transcranial direct current stimulation over the damaged cerebral hemisphere + cathodal transcutaneous spinal direct current stimulation. The primary outcome was the 6-minute walk test performed before, after, and at follow-up at 2 and 4 weeks post-treatment. The significant differences in the 6-minute walk test noted between groups at the first post-treatment evaluation (p = 0.041) were not maintained at either the 2-week (P = 0.650) or the 4-week (P = 0.545) follow-up evaluations. Our preliminary findings support the hypothesis that cathodal transcranial direct current stimulation over the contralesional cerebellar hemisphere in combination with cathodal transcutaneous spinal direct current stimulation might be useful to boost the effects of robot-assisted gait training in chronic brain stroke patients with walking impairment.
Powered robotic exoskeletons in post-stroke rehabilitation of gait: a scoping review.
Louie, Dennis R; Eng, Janice J
2016-06-08
Powered robotic exoskeletons are a potential intervention for gait rehabilitation in stroke to enable repetitive walking practice to maximize neural recovery. As this is a relatively new technology for stroke, a scoping review can help guide current research and propose recommendations for advancing the research development. The aim of this scoping review was to map the current literature surrounding the use of robotic exoskeletons for gait rehabilitation in adults post-stroke. Five databases (Pubmed, OVID MEDLINE, CINAHL, Embase, Cochrane Central Register of Clinical Trials) were searched for articles from inception to October 2015. Reference lists of included articles were reviewed to identify additional studies. Articles were included if they utilized a robotic exoskeleton as a gait training intervention for adult stroke survivors and reported walking outcome measures. Of 441 records identified, 11 studies, all published within the last five years, involving 216 participants met the inclusion criteria. The study designs ranged from pre-post clinical studies (n = 7) to controlled trials (n = 4); five of the studies utilized a robotic exoskeleton device unilaterally, while six used a bilateral design. Participants ranged from sub-acute (<7 weeks) to chronic (>6 months) stroke. Training periods ranged from single-session to 8-week interventions. Main walking outcome measures were gait speed, Timed Up and Go, 6-min Walk Test, and the Functional Ambulation Category. Meaningful improvement with exoskeleton-based gait training was more apparent in sub-acute stroke compared to chronic stroke. Two of the four controlled trials showed no greater improvement in any walking outcomes compared to a control group in chronic stroke. In conclusion, clinical trials demonstrate that powered robotic exoskeletons can be used safely as a gait training intervention for stroke. Preliminary findings suggest that exoskeletal gait training is equivalent to traditional therapy for chronic stroke patients, while sub-acute patients may experience added benefit from exoskeletal gait training. Efforts should be invested in designing rigorous, appropriately powered controlled trials before powered exoskeletons can be translated into a clinical tool for gait rehabilitation post-stroke.
STS-61 crew utilizing Virtual Reality in training for HST repair mission
1993-06-11
Astronaut Jeffrey A. Hoffman, one of four crewmembers for STS-61 that will conduct scheduled spacewalks during the flight, wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm. Crewmembers are utilizing a new virtual reality training aid which assists in refining positioning patterns for Space Shuttle Endeavour's Remote Manipulator System (RMS) (36890); Astronaut Claude Nicollier looks at a computer display of the Shuttle's robot arm movements as Thomas D. Akers and Kathryn C. Thornton, mission specialists look on. Nicollier will be responsible for maneuvering the astronauts while they stand in a foot restraint on the end of the RMS arm (36891,36894); Hoffman wears a special helmet and gloves designed to assist in proper positioning near the telescope while on the end of the robot arm (35892); Nicollier looks at a computer display of the Shuttle's robot arm movements as Akers looks on (36893); While (l-r) Astronauts Kenneth Bowersox, Kathryn Thornton, Richard O. Covey and Thomas D. Akers watch, Nicollier moves the Robot arm to desired locations in the Shuttle's payload bay using the Virtual Reality program (36895); Bowersox takes his turn maneuvering the RMS while mission specialist Hoffman, wearing the Virtual Reality helmet, follows his own progress on the end of the robot arm. Crewmembers participating during the training session are (l-r) Astronauts Akers, Hoffman, Bowersox, Nicollier, Covey, and Thornton. In the background, David Homan, an engineer in the JSC Engineering Directorate's Automation and Robotics Division, looks on (36896).
Rapid Prototyping Platform for Robotics Applications
ERIC Educational Resources Information Center
Hwang, Kao-Shing; Hsiao, Wen-Hsu; Shing, Gaung-Ting; Chen, Kim-Joan
2011-01-01
For the past several years, a team in the Department of Electrical Engineering (EE), National Chung Cheng University, Taiwan, has been establishing a pedagogical approach to embody embedded systems in the context of robotics. To alleviate the burden on students in the robotics curriculum in their junior and senior years, a training platform on…
Robots, Jobs, and Education. State-of-the-Art Paper.
ERIC Educational Resources Information Center
Benton, Oliver; Branch, Charles W.
The purpose of this paper is to assist those in education, government, and industry who are responsible for managing vocational and technical training in their decisions about what programs should be initiated to accommodate the growing use of robots. Section 1 describes robot characteristics (type of drive, method of teaching, lifting capacity,…
Robot-Assisted Task-Specific Training in Cerebral Palsy
ERIC Educational Resources Information Center
Krebs, Hermano I.; Ladenheim, Barbara; Hippolyte, Christopher; Monterroso, Linda; Mast, Joelle
2009-01-01
Our goal was to examine the feasibility of applying therapeutic robotics to children and adults with severe to moderate impairment due to cerebral palsy (CP). Pilot results demonstrated significant gains for both groups. These results suggest that robot-mediated therapy may be an effective tool to ameliorate the debilitating effects of CP and…
Learning Probabilistic Features for Robotic Navigation Using Laser Sensors
Aznar, Fidel; Pujol, Francisco A.; Pujol, Mar; Rizo, Ramón; Pujol, María-José
2014-01-01
SLAM is a popular task used by robots and autonomous vehicles to build a map of an unknown environment and, at the same time, to determine their location within the map. This paper describes a SLAM-based, probabilistic robotic system able to learn the essential features of different parts of its environment. Some previous SLAM implementations had computational complexities ranging from O(Nlog(N)) to O(N 2), where N is the number of map features. Unlike these methods, our approach reduces the computational complexity to O(N) by using a model to fuse the information from the sensors after applying the Bayesian paradigm. Once the training process is completed, the robot identifies and locates those areas that potentially match the sections that have been previously learned. After the training, the robot navigates and extracts a three-dimensional map of the environment using a single laser sensor. Thus, it perceives different sections of its world. In addition, in order to make our system able to be used in a low-cost robot, low-complexity algorithms that can be easily implemented on embedded processors or microcontrollers are used. PMID:25415377
Learning probabilistic features for robotic navigation using laser sensors.
Aznar, Fidel; Pujol, Francisco A; Pujol, Mar; Rizo, Ramón; Pujol, María-José
2014-01-01
SLAM is a popular task used by robots and autonomous vehicles to build a map of an unknown environment and, at the same time, to determine their location within the map. This paper describes a SLAM-based, probabilistic robotic system able to learn the essential features of different parts of its environment. Some previous SLAM implementations had computational complexities ranging from O(Nlog(N)) to O(N(2)), where N is the number of map features. Unlike these methods, our approach reduces the computational complexity to O(N) by using a model to fuse the information from the sensors after applying the Bayesian paradigm. Once the training process is completed, the robot identifies and locates those areas that potentially match the sections that have been previously learned. After the training, the robot navigates and extracts a three-dimensional map of the environment using a single laser sensor. Thus, it perceives different sections of its world. In addition, in order to make our system able to be used in a low-cost robot, low-complexity algorithms that can be easily implemented on embedded processors or microcontrollers are used.
Systematic Review of Appropriate Robotic Intervention for Gait Function in Subacute Stroke Patients
Yoo, Jun Sang; Kim, Kyoung Eun; Cho, Sung Tae; Jang, Woo Seok
2018-01-01
The purpose of this study was to critically evaluate the effects of robot-assisted gait training (RAGT) on gait-related function in patients with acute/subacute stroke. We conducted a systematic review of randomized controlled trials published between May 2012 and April 2016. This search included 334 articles (Cochrane, 51 articles; Embase, 175 articles; PubMed, 108 articles). Based on the inclusion and exclusion criteria, 7 studies were selected for this review. We performed a quality evaluation using the PEDro scale. In this review, 3 studies used an exoskeletal robot, and 4 studies used an end-effector robot as interventions. As a result, RAGT was found to be effective in improving walking ability in subacute stroke patients. Significant improvements in gait speed, functional ambulatory category, and Rivermead mobility index were found with RAGT compared with conventional physical therapy (p < 0.05). Therefore, aggressive weight support and gait training at an early stage using a robotic device are helpful, and robotic intervention should be applied according to the patient's functional level and onset time of stroke. PMID:29546057
Surgical flow disruptions during robotic-assisted radical prostatectomy.
Dru, Christopher J; Anger, Jennifer T; Souders, Colby P; Bresee, Catherine; Weigl, Matthias; Hallett, Elyse; Catchpole, Ken
2017-06-01
We sought to apply the principles of human factors research to robotic-assisted radical prostatectomy to understand where training and integration challenges lead to suboptimal and inefficient care. Thirty-four robotic-assisted radical prostatectomy and bilateral pelvic lymph node dissections over a 20 week period were observed for flow disruptions (FD) - deviations from optimal care that can compromise safety or efficiency. Other variables - physician experience, trainee involvement, robot model (S versus Si), age, body mass index (BMI), and American Society of Anesthesiologists (ASA) physical status - were used to stratify the data and understand the effect of context. Effects were studied across four operative phases - entry to insufflations, robot docking, surgical intervention, and undocking. FDs were classified into one of nine categories. An average of 9.2 (SD = 3.7) FD/hr were recorded, with the highest rates during robot docking (14.7 [SD = 4.3] FDs/hr). The three most common flow disruptions were disruptions of communication, coordination, and equipment. Physicians with more robotic experience were faster during docking (p < 0.003). Training cases had a greater FD rate (8.5 versus 10.6, p < 0.001), as did the Si model robot (8.2 versus 9.8, p = 0.002). Patient BMI and ASA classification yielded no difference in operative duration, but had phase-specific differences in FD. Our data reflects the demands placed on the OR team by the patient, equipment, environment and context of a robotic surgical intervention, and suggests opportunities to enhance safety, quality, efficiency, and learning in robotic surgery.
Study on development of active-passive rehabilitation system for upper limbs: Hybrid-PLEMO
NASA Astrophysics Data System (ADS)
Kikuchi, T.; Jin, Y.; Fukushima, K.; Akai, H.; Furusho, J.
2009-02-01
In recent years, many researchers have studied the potential of using robotics technology to assist and quantify the motor functions for neuron-rehabilitation. Some kinds of haptic devices have been developed and evaluated its efficiency with clinical tests, for example, upper limb training for patients with spasticity after stroke. Active-type (motor-driven) haptic devices can realize a lot of varieties of haptics. But they basically require high-cost safety system. On the other hand, passive-type (brake-based) haptic devices have inherent safety. However, the passive robot system has strong limitation on varieties of haptics. There are not sufficient evidences to clarify how the passive/active haptics effect to the rehabilitation of motor skills. In this paper, we developed an active-passive-switchable rehabilitation system with ER clutch/brake device named "Hybrid-PLEMO" in order to address these problems. In this paper, basic structures and haptic control methods of the Hybrid-PLEMO are described.
Wei, Xi-Jun; Tong, Kai-Yu; Hu, Xiao-Ling
2011-12-01
Responsiveness of clinical assessments is an important element in the report of clinical effectiveness after rehabilitation. The correlation could reflect the validity of assessments as an indication of clinical performance before and after interventions. This study investigated the correlation and responsiveness of Fugl-Meyer Assessment (FMA), Motor Status Scale (MSS), Action Research Arm Test (ARAT) and the Modified Ashworth Scale (MAS), which are used frequently in effectiveness studies of robotic upper-extremity training in stroke rehabilitation. Twenty-seven chronic stroke patients were recruited for a 20-session upper-extremity rehabilitation robotic training program. This was a rater-blinded randomized controlled trial. All participants were evaluated with FMA, MSS, ARAT, MAS, and Functional Independent Measure before and after robotic training. Spearman's rank correlation coefficient was applied for the analysis of correlation. The standardized response mean (SRM) and Guyatt's responsiveness index (GRI) were used to analyze responsiveness. Spearman's correlation coefficient showed a significantly high correlation (ρ=0.91-0.96) among FMA, MSS, and ARAT and a fair-to-moderate correlation (ρ=0.40-0.62) between MAS and the other assessments. FMA, MSS, and MAS on the wrist showed higher responsiveness (SRM=0.85-0.98, GRI=1.59-3.62), whereas ARAT showed relatively less responsiveness (SRM=0.22, GRI=0.81). The results showed that FMA or MSS would be the best choice for evaluating the functional improvement in stroke studies on robotic upper-extremity training with high responsiveness and good correlation with ARAT. MAS could be used separately to evaluate the spasticity changes after intervention in terms of high responsiveness.
Pizzamiglio, Sara; Desowska, Adela; Shojaii, Pegah; Taga, Myriam; Turner, Duncan L
2017-01-01
Muscle co-contraction is a strategy of increasing movement accuracy and stability employed in dealing with force perturbation of movement. It is often seen in neuropathological populations. The direction of movement influences the pattern of co-contraction, but not all movements are easily achievable for populations with motor deficits. Manipulating the direction of the force instead, may be a promising rehabilitation protocol to train movement with use of a co-contraction reduction strategy. Force field learning paradigms provide a well described procedure to evoke and test muscle co-contraction. The aim of this study was to test the muscle co-contraction pattern in a wide range of arm muscles in different force-field directions utilising a robot-mediated force field learning paradigm of motor adaptation. Forty-two participants volunteered to participate in a study utilising robot-mediated force field motor adaptation paradigm with a clockwise or counter-clockwise force field. Kinematics and surface electromyography (EMG) of eight arm muscles were measured. Both muscle activation and co-contraction was earlier and stronger in flexors in the clockwise condition and in extensors in the counter-clockwise condition. Manipulating the force field direction leads to changes in the pattern of muscle co-contraction.
Design of a robotic device for assessment and rehabilitation of hand sensory function.
Lambercy, Olivier; Robles, Alejandro Juárez; Kim, Yeongmi; Gassert, Roger
2011-01-01
This paper presents the design and implementation of the Robotic Sensory Trainer, a robotic interface for assessment and therapy of hand sensory function. The device can provide three types of well controlled stimuli: (i) angular displacement at the metacarpophalangeal (MCP) joint using a remote-center-of-motion double-parallelogram structure, (ii) vibration stimuli at the fingertip, proximal phalange and palm, and (iii) pressure at the fingertip, while recording position, interaction force and feedback from the user over a touch screen. These stimuli offer a novel platform to investigate sensory perception in healthy subjects and patients with sensory impairments, with the potential to assess deficits and actively train detection of specific sensory cues in a standardized manner. A preliminary study with eight healthy subjects demonstrates the feasibility of using the Robotic Sensory Trainer to assess the sensory perception threshold in MCP angular position. An average just noticeable difference (JND) in the MCP joint angle of 2.46° (14.47%) was found, which is in agreement with previous perception studies. © 2011 IEEE
Koenig, Alexander; Novak, Domen; Omlin, Ximena; Pulfer, Michael; Perreault, Eric; Zimmerli, Lukas; Mihelj, Matjaz; Riener, Robert
2011-08-01
Cognitively challenging training sessions during robot-assisted gait training after stroke were shown to be key requirements for the success of rehabilitation. Despite a broad variability of cognitive impairments amongst the stroke population, current rehabilitation environments do not adapt to the cognitive capabilities of the patient, as cognitive load cannot be objectively assessed in real-time. We provided healthy subjects and stroke patients with a virtual task during robot-assisted gait training, which allowed modulating cognitive load by adapting the difficulty level of the task. We quantified the cognitive load of stroke patients by using psychophysiological measurements and performance data. In open-loop experiments with healthy subjects and stroke patients, we obtained training data for a linear, adaptive classifier that estimated the current cognitive load of patients in real-time. We verified our classification results via questionnaires and obtained 88% correct classification in healthy subjects and 75% in patients. Using the pre-trained, adaptive classifier, we closed the cognitive control loop around healthy subjects and stroke patients by automatically adapting the difficulty level of the virtual task in real-time such that patients were neither cognitively overloaded nor under-challenged. © 2011 IEEE
Cundy, Thomas P; Mayer, Erik K; Camps, Juan I; Olsen, Lars H; Pelizzo, Gloria; Yang, Guang-Zhong; Darzi, Ara; Najmaldin, Azad S
2015-03-01
The introduction of robotic surgery into clinical practice brings new and specific needs for education and training. Application to the pediatric setting comes with unique considerations, warranting dedicated training resources that are accessible. A pediatric robotic surgery workshop was convened to address initial education and training requirements. The event was designed to offer an exposure rich environment for delegates to familiarize and learn basic principles in a maximally efficient manner. Pre- and post-workshop survey responses were evaluated to reflect on the quality of the educational experience and scope for improvement. Feasibility and sustainability of such events was further evaluated by reviewing various challenges encountered. A total of 29 surgeons participated in the workshop, with 7 countries represented. The majority of delegates (94 %) indicated they were "very satisfied" with the overall program. Delegates almost unanimously expressed preference and satisfaction for hands-on content. Qualitative feedback favored a stepwise and modular workshop structure, transitioning from didactic teaching to progressively more advanced training. At the basic and intermediate level, this style of event is able to satisfy initial training and educational needs. Feasibility and sustainability of such events is highly dependent on infrastructure resources that have numerous barriers to accessibility.
[Robotic surgery: toy or tool?].
Vallancien, Guy; Cathelineau, Xavier; Rozet, François; Barret, Eric
2005-05-01
Telemanipulation has been developed for industrial purposes since the 1970s. More recently, telemanipulated arms entered the operating room. This paper briefly describes the history of surgical robotics and discusses the advantages and disadvantages for both patients and surgeons. The authors advocate the development of robotic surgery, as it facilitates the training of young surgeons and can be useful during certain phases of an operation. Thus, robotic surgery is more a promising tool than a simple toy.
NASA Astrophysics Data System (ADS)
Nair, Binu M.; Diskin, Yakov; Asari, Vijayan K.
2012-10-01
We present an autonomous system capable of performing security check routines. The surveillance machine, the Clearpath Husky robotic platform, is equipped with three IP cameras with different orientations for the surveillance tasks of face recognition, human activity recognition, autonomous navigation and 3D reconstruction of its environment. Combining the computer vision algorithms onto a robotic machine has given birth to the Robust Artificial Intelligencebased Defense Electro-Robot (RAIDER). The end purpose of the RAIDER is to conduct a patrolling routine on a single floor of a building several times a day. As the RAIDER travels down the corridors off-line algorithms use two of the RAIDER's side mounted cameras to perform a 3D reconstruction from monocular vision technique that updates a 3D model to the most current state of the indoor environment. Using frames from the front mounted camera, positioned at the human eye level, the system performs face recognition with real time training of unknown subjects. Human activity recognition algorithm will also be implemented in which each detected person is assigned to a set of action classes picked to classify ordinary and harmful student activities in a hallway setting.The system is designed to detect changes and irregularities within an environment as well as familiarize with regular faces and actions to distinguish potentially dangerous behavior. In this paper, we present the various algorithms and their modifications which when implemented on the RAIDER serves the purpose of indoor surveillance.
Gross, Neil D; Holsinger, F Christopher; Magnuson, J Scott; Duvvuri, Umamaheswar; Genden, Eric M; Ghanem, Tamer Ah; Yaremchuk, Kathleen L; Goldenberg, David; Miller, Matthew C; Moore, Eric J; Morris, Luc Gt; Netterville, James; Weinstein, Gregory S; Richmon, Jeremy
2016-04-01
Training and credentialing for robotic surgery in otolaryngology - head and neck surgery is currently not standardized, but rather relies heavily on industry guidance. This manuscript represents a comprehensive review of this increasingly important topic and outlines clear recommendations to better standardize the practice. The recommendations provided can be used as a reference by individuals and institutions alike, and are expected to evolve over time. © 2016 Wiley Periodicals, Inc. Head Neck 38: E151-E158. © 2016 Wiley Periodicals, Inc.
An architectural approach to create self organizing control systems for practical autonomous robots
NASA Technical Reports Server (NTRS)
Greiner, Helen
1991-01-01
For practical industrial applications, the development of trainable robots is an important and immediate objective. Therefore, the developing of flexible intelligence directly applicable to training is emphasized. It is generally agreed upon by the AI community that the fusion of expert systems, neural networks, and conventionally programmed modules (e.g., a trajectory generator) is promising in the quest for autonomous robotic intelligence. Autonomous robot development is hindered by integration and architectural problems. Some obstacles towards the construction of more general robot control systems are as follows: (1) Growth problem; (2) Software generation; (3) Interaction with environment; (4) Reliability; and (5) Resource limitation. Neural networks can be successfully applied to some of these problems. However, current implementations of neural networks are hampered by the resource limitation problem and must be trained extensively to produce computationally accurate output. A generalization of conventional neural nets is proposed, and an architecture is offered in an attempt to address the above problems.
Tubbs, R. Shane; Page, Jeni; Chapman, Alexandra; Burgess, Brittni; Laws, Tyler; Warren, Haylie; Oskouian, Rod J
2016-01-01
The operative microscope has been a staple instrument in the neurosurgical operating room over the last 50 years. With advances in optoelectronics, options such as robotically controlled high magnification have become available. Such robotically controlled optoelectronic systems may offer new opportunities in surgical technique and teaching. However, traditionally trained surgeons may find it hard to accept newer technologies due to an inherent bias emerging from their previous background. We, therefore, studied how a medically naïve population in a pilot study would meet set microsurgical goals in a cadaver experiment using either a conventional operative microscope or BrightMatter™ Servo system, a robotically controlled optoelectronic system (Synaptive Medical, Toronto, Ontario, Canada). We found that the relative ease in teaching medical novices with a robotically controlled optoelectronic system was more valuable when compared to using a modern-day surgical microscope. PMID:26973804
Torque Control of a Rehabilitation Teaching Robot Using Magneto-Rheological Fluid Clutches
NASA Astrophysics Data System (ADS)
Hakogi, Hokuto; Ohaba, Motoyoshi; Kuramochi, Naimu; Yano, Hidenori
A new robot that makes use of MR-fluid clutches for simulating torque is proposed to provide an appropriate device for training physical therapy students in knee-joint rehabilitation. The feeling of torque provided by the robot is expected to correspond to the torque performance obtained by physical therapy experts in a clinical setting. The torque required for knee-joint rehabilitation, which is a function of the rotational angle and the rotational angular velocity of a knee movement, is modeled using a mechanical system composed of typical spring-mass-damper elements. The robot consists of two MR-fluid clutches, two induction motors, and a feedback control system. In the torque experiments, output torque is controlled using the spring and damper coefficients separately. The values of these coefficients are determined experimentally. The experimental results show that the robot would be suitable for training physical therapy students to experience similar torque feelings as needed in a clinical situation.
Path optimisation of a mobile robot using an artificial neural network controller
NASA Astrophysics Data System (ADS)
Singh, M. K.; Parhi, D. R.
2011-01-01
This article proposed a novel approach for design of an intelligent controller for an autonomous mobile robot using a multilayer feed forward neural network, which enables the robot to navigate in a real world dynamic environment. The inputs to the proposed neural controller consist of left, right and front obstacle distance with respect to its position and target angle. The output of the neural network is steering angle. A four layer neural network has been designed to solve the path and time optimisation problem of mobile robots, which deals with the cognitive tasks such as learning, adaptation, generalisation and optimisation. A back propagation algorithm is used to train the network. This article also analyses the kinematic design of mobile robots for dynamic movements. The simulation results are compared with experimental results, which are satisfactory and show very good agreement. The training of the neural nets and the control performance analysis has been done in a real experimental setup.
Design and evaluation of a trilateral shared-control architecture for teleoperated training robots.
Shamaei, Kamran; Kim, Lawrence H; Okamura, Allison M
2015-08-01
Multilateral teleoperated robots can be used to train humans to perform complex tasks that require collaborative interaction and expert supervision, such as laparoscopic surgical procedures. In this paper, we explain the design and performance evaluation of a shared-control architecture that can be used in trilateral teleoperated training robots. The architecture includes dominance and observation factors inspired by the determinants of motor learning in humans, including observational practice, focus of attention, feedback and augmented feedback, and self-controlled practice. Toward the validation of such an architecture, we (1) verify the stability of a trilateral system by applying Llewellyn's criterion on a two-port equivalent architecture, and (2) demonstrate that system transparency remains generally invariant across relevant observation factors and movement frequencies. In a preliminary experimental study, a dyad of two human users (one novice, one expert) collaborated on the control of a robot to follow a trajectory. The experiment showed that the framework can be used to modulate the efforts of the users and adjust the source and level of haptic feedback to the novice user.
A novel 3D-printed hybrid simulation model for robotic-assisted kidney transplantation (RAKT).
Uwechue, Raphael; Gogalniceanu, Petrut; Kessaris, Nicos; Byrne, Nick; Chandak, Pankaj; Olsburgh, Jonathon; Ahmed, Kamran; Mamode, Nizam; Loukopoulos, Ioannis
2018-01-27
Robotic-assisted kidney transplantation (RAKT) offers key benefits for patients that have been demonstrated in several studies. A barrier to the wider uptake of RAKT is surgical skill acquisition. This is exacerbated by the challenges of modern surgery with reduced surgical training time, patient safety concerns and financial pressures. Simulation is a well-established method of developing surgical skill in a safe and controlled environment away from the patient. We have developed a 3D printed simulation model for the key step of the kidney transplant operation which is the vascular anastomosis. The model is anatomically accurate, based on the CT scans of patients and it incorporates deceased donor vascular tissue. Crucially, it was developed to be used in the robotic operating theatre with the operating robot to enhance its fidelity. It is portable and relatively inexpensive when compared with other forms of simulation such as virtual reality or animal lab training. It thus has the potential of being more accessible as a training tool for the safe acquisition of RAKT specific skills. We demonstrate this model here.
How training and experience affect the benefits of autonomy in a dirty-bomb experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
David J. Bruemmer; Curtis W. Nielsen; David I. Gertman
2008-03-01
A dirty-bomb experiment conducted at the INL is used to evaluate the effectiveness and suitability of three different modes of robot control. The experiment uses three distinct user groups to understand how participants’ background and training affect the way in which they use and benefit from autonomy. The results show that the target mode, which involves automated mapping and plume tracing together with a point and click tasking tool, provides the best performance for each group. This is true for objective performance such as source detection and localization accuracy as well as subjective measures such as perceived workload, frustration andmore » preference. The best overall performance is achieved by the Explosive Ordinance Disposal group which has experience in both robot teleoperation and dirty bomb response. The user group that benefits least from autonomy is the Nuclear Engineers that have no experience with either robot operation or dirty bomb response. The group that benefits most from autonomy is the Weapons of Mass Destruction Civil Response Team that has extensive experience related to the task, but no robot training.« less
Robotics in otolaryngology and head and neck surgery: Recommendations for training and credentialing
Gross, Neil D.; Holsinger, F. Christopher; Magnuson, J. Scott; Duvvuri, Umamaheswar; Genden, Eric M.; Ghanem, Tamer AH.; Yaremchuk, Kathleen L.; Goldenberg, David; Miller, Matthew C.; Moore, Eric J.; Morris, Luc GT.; Netterville, James; Weinstein, Gregory S.; Richmon, Jeremy
2016-01-01
Training and credentialing for robotic surgery in otolaryngology - head and neck surgery is currently not standardized, but rather relies heavily on industry guidance. This manuscript represents a comprehensive review of this increasingly important topic and outlines clear recommendations to better standardize the practice. The recommendations provided can be used as a reference by individuals and institutions alike, and are expected to evolve over time. PMID:26950771
Goodman, Ronald N; Rietschel, Jeremy C; Roy, Anindo; Jung, Brian C; Diaz, Jason; Macko, Richard F; Forrester, Larry W
2014-01-01
Robotics is rapidly emerging as a viable approach to enhance motor recovery after disabling stroke. Current principles of cognitive motor learning recognize a positive relationship between reward and motor learning. Yet no prior studies have established explicitly whether reward improves the rate or efficacy of robotics-assisted rehabilitation or produces neurophysiologic adaptations associated with motor learning. We conducted a 3 wk, 9-session clinical pilot with 10 people with chronic hemiparetic stroke, randomly assigned to train with an impedance-controlled ankle robot (anklebot) under either high reward (HR) or low reward conditions. The 1 h training sessions entailed playing a seated video game by moving the paretic ankle to hit moving onscreen targets with the anklebot only providing assistance as needed. Assessments included paretic ankle motor control, learning curves, electroencephalograpy (EEG) coherence and spectral power during unassisted trials, and gait function. While both groups exhibited changes in EEG, the HR group had faster learning curves (p = 0.05), smoother movements (p = 0.05), reduced contralesional-frontoparietal coherence (p = 0.05), and reduced left-temporal spectral power (p = 0.05). Gait analyses revealed an increase in nonparetic step length (p = 0.05) in the HR group only. These results suggest that combining explicit rewards with novel anklebot training may accelerate motor learning for restoring mobility.
Del-Ama, Antonio J; Gil-Agudo, Angel; Pons, José L; Moreno, Juan C
2014-01-01
Locomotor training has proved to provide beneficial effect in terms of mobility in incomplete paraplegic patients. Neuroprosthetic technology can contribute to increase the efficacy of a training paradigm in the promotion of a locomotor pattern. Robotic exoskeletons can be used to manage the unavoidable loss of performance of artificially driven muscles. Hybrid exoskeletons blend complementary robotic and neuro-prosthetic technologies. The aim of this pilot study was to determine the effects of hybrid gait training in three case studies with persons with incomplete spinal cord injury (iSCI) in terms of locomotion performance during assisted gait, patient-robot adaptations, impact on ambulation and assessment of lower limb muscle strength and spasticity. Participants with iSCI received interventions with a hybrid bilateral exoskeleton for 4 days. Assessment of gait function revealed that patients improved the 6 min and 10 m walking tests after the intervention, and further improvements were observed 1 week after the intervention. Muscle examination revealed improvements in knee and hip sagittal muscle balance scores and decreased score in ankle extensor balance. It is concluded that improvements in biomechanical function of the knee joint after the tested overground hybrid gait trainer are coherent with improvements in gait performance.
del-Ama, Antonio J.; Gil-Agudo, Ángel; Pons, José L.; Moreno, Juan C.
2014-01-01
Locomotor training has proved to provide beneficial effect in terms of mobility in incomplete paraplegic patients. Neuroprosthetic technology can contribute to increase the efficacy of a training paradigm in the promotion of a locomotor pattern. Robotic exoskeletons can be used to manage the unavoidable loss of performance of artificially driven muscles. Hybrid exoskeletons blend complementary robotic and neuro-prosthetic technologies. The aim of this pilot study was to determine the effects of hybrid gait training in three case studies with persons with incomplete spinal cord injury (iSCI) in terms of locomotion performance during assisted gait, patient-robot adaptations, impact on ambulation and assessment of lower limb muscle strength and spasticity. Participants with iSCI received interventions with a hybrid bilateral exoskeleton for 4 days. Assessment of gait function revealed that patients improved the 6 min and 10 m walking tests after the intervention, and further improvements were observed 1 week after the intervention. Muscle examination revealed improvements in knee and hip sagittal muscle balance scores and decreased score in ankle extensor balance. It is concluded that improvements in biomechanical function of the knee joint after the tested overground hybrid gait trainer are coherent with improvements in gait performance. PMID:24860478
Technological advances in robotic-assisted laparoscopic surgery.
Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K
2009-05-01
In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.
Speeding up the learning of robot kinematics through function decomposition.
Ruiz de Angulo, Vicente; Torras, Carme
2005-11-01
The main drawback of using neural networks or other example-based learning procedures to approximate the inverse kinematics (IK) of robot arms is the high number of training samples (i.e., robot movements) required to attain an acceptable precision. We propose here a trick, valid for most industrial robots, that greatly reduces the number of movements needed to learn or relearn the IK to a given accuracy. This trick consists in expressing the IK as a composition of learnable functions, each having half the dimensionality of the original mapping. Off-line and on-line training schemes to learn these component functions are also proposed. Experimental results obtained by using nearest neighbors and parameterized self-organizing map, with and without the decomposition, show that the time savings granted by the proposed scheme grow polynomially with the precision required.
The effect of a robot-assisted surgical system on the kinematics of user movements.
Nisky, Ilana; Hsieh, Michael H; Okamura, Allison M
2013-01-01
Teleoperated robot-assisted surgery (RAS) offers many advantages over traditional minimally invasive surgery. However, RAS has not yet realized its full potential, and it is not clear how to optimally train surgeons to use these systems. We hypothesize that the dynamics of the master manipulator impact the ability of users to make desired movements with the robot. We compared freehand and teleoperated movements of novices and experienced surgeons. To isolate the effects of dynamics from procedural knowledge, we chose simple movements rather than surgical tasks. We found statistically significant effects of teleoperation and user expertise in several aspects of motion, including target acquisition error, movement speed, and movement smoothness. Such quantitative assessment of human motor performance in RAS can impact the design of surgical robots, their control, and surgeon training methods, and eventually, improve patient outcomes.