Science.gov

Sample records for active sampling method

  1. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    PubMed

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  2. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    USGS Publications Warehouse

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  3. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    PubMed

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. PMID:24419241

  4. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    PubMed

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided.

  5. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    PubMed

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided. PMID:26732526

  6. Sampling system and method

    DOEpatents

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  7. Rapid Active Sampling Package

    NASA Technical Reports Server (NTRS)

    Peters, Gregory

    2010-01-01

    A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni

  8. Determination of trace halogens in rock samples by radiochemical neutron activation analysis coupled with the k0-standardization method.

    PubMed

    Ozaki, Hiromasa; Ebihara, Mitsuru

    2007-02-01

    Radiochemical neutron activation analysis coupled with the k0-standardization method (k0-RNAA method) was applied to silicate rock samples for the simultaneous determination of trace halogens (Cl, Br and I). Analytical results obtained by the k0-RNAA method for geological standard rocks and meteorite samples agreed with those determined by the conventional comparison method conducted in the same set of experiments, suggesting that the k0-RNAA method is as reliable as the conventional method. Our data for these samples are in good agreement with their literature values except for rare cases. Detection limits calculated under the present experimental condition are sufficiently low for Cl and Br but not for I for typical geologic and meteoritic samples. The k0-RNAA method coupled with longer neutron-irradiation is expected to yield satisfactorily low detection limits for halogens including I in these samples.

  9. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  10. Methods for preparing comparative standards and field samples for neutron activation analysis of soil

    SciTech Connect

    Glasgow, D.C.; Dyer, F.F.; Robinson, L.

    1994-06-01

    One of the more difficult problems associated with comparative neutron activation analysis (CNAA) is the preparation of standards which are tailor-made to the desired irradiation and counting conditions. Frequently, there simply is not a suitable standard available commercially, or the resulting gamma spectrum is convoluted with interferences. In a recent soil analysis project, the need arose for standards which contained about 35 elements. In response, a computer spreadsheet was developed to calculate the appropriate amount of each element so that the resulting gamma spectrum is relatively free of interferences. Incorporated in the program are options for calculating all of the irradiation and counting parameters including activity produced, necessary flux/bombardment time, counting time, and appropriate source-to-detector distance. The result is multi-element standards for CNAA which have optimal concentrations. The program retains ease of use without sacrificing capability. In addition to optimized standard production, a novel soil homogenization technique was developed which is a low cost, highly efficient alternative to commercially available homogenization systems. Comparative neutron activation analysis for large scale projects has been made easier through these advancements. This paper contains details of the design and function of the NAA spreadsheet and innovative sample handling techniques.

  11. Azocasein Substrate for Determination of Proteolytic Activity: Reexamining a Traditional Method Using Bromelain Samples.

    PubMed

    Coêlho, Diego F; Saturnino, Thais Peron; Fernandes, Fernanda Freitas; Mazzola, Priscila Gava; Silveira, Edgar; Tambourgi, Elias Basile

    2016-01-01

    Given the importance of protease's worldwide market, the determination of optimum conditions and the development of a standard protocol are critical during selection of a reliable method to determine its bioactivity. This paper uses quality control theory to validate a modified version of a method proposed by Charney and Tomarelli in 1947. The results obtained showed that using azocasein substrate bromelain had its optimum at 45°C and pH 9 (Glycine-NaOH 100 mM). We also quantified the limit of detection (LoD) and limit of quantification (LoQ) in the above-mentioned optimum (0.072 and 0.494 mg·mL(-1) of azocasein, resp.) and a calibration curve that correlates optical density with the amount of substrate digested. In all analysed samples, we observed a significant decrease in response after storage (around 17%), which suggests its use must be immediately after preparation. Thus, the protocol presented in this paper offers a significant improvement, given that subjective definitions are commonly used in the literature and this simple mathematical approach makes it clear and concise. PMID:26925415

  12. Azocasein Substrate for Determination of Proteolytic Activity: Reexamining a Traditional Method Using Bromelain Samples

    PubMed Central

    Mazzola, Priscila Gava

    2016-01-01

    Given the importance of protease's worldwide market, the determination of optimum conditions and the development of a standard protocol are critical during selection of a reliable method to determine its bioactivity. This paper uses quality control theory to validate a modified version of a method proposed by Charney and Tomarelli in 1947. The results obtained showed that using azocasein substrate bromelain had its optimum at 45°C and pH 9 (Glycine-NaOH 100 mM). We also quantified the limit of detection (LoD) and limit of quantification (LoQ) in the above-mentioned optimum (0.072 and 0.494 mg·mL−1 of azocasein, resp.) and a calibration curve that correlates optical density with the amount of substrate digested. In all analysed samples, we observed a significant decrease in response after storage (around 17%), which suggests its use must be immediately after preparation. Thus, the protocol presented in this paper offers a significant improvement, given that subjective definitions are commonly used in the literature and this simple mathematical approach makes it clear and concise. PMID:26925415

  13. Improved Sampling Method Reduces Isokinetic Sampling Errors.

    ERIC Educational Resources Information Center

    Karels, Gale G.

    The particulate sampling system currently in use by the Bay Area Air Pollution Control District, San Francisco, California is described in this presentation for the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971. The method represents a practical, inexpensive tool that can…

  14. Final Project Report for the Development of an Active Soil Gas Sampling Method

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) is charged by Congress with protecting the nation's natural resources. Under the mandate of national environmental laws, the EPA strives to formulate and implement actions leading to a compatible balance between human activities and ...

  15. Sampling methods for phlebotomine sandflies.

    PubMed

    Alexander, B

    2000-06-01

    A review is presented of methods for sampling phlebotomine sandflies (Diptera: Psychodidae). Among approximately 500 species of Phlebotominae so far described, mostly in the New World genus Lutzomyia and the Old World genus Phlebotomus, about 10% are known vectors of Leishmania parasites or other pathogens. Despite being small and fragile, sandflies have a wide geographical range with species occupying a considerable diversity of ecotopes and habitats, from deserts to humid forests, so that suitable methods for collecting them are influenced by environmental conditions where they are sought. Because immature phlebotomines occupy obscure terrestrial habitats, it is difficult to find their breeding sites. Therefore, most trapping methods and sampling procedures focus on sandfly adults, whether resting or active. The diurnal resting sites of adult sandflies include tree holes, buttress roots, rock crevices, houses, animal shelters and burrows, from which they may be aspirated directly or trapped after being disturbed. Sandflies can be collected during their periods of activity by interception traps, or by using attractants such as bait animals, CO2 or light. The method of trapping used should: (a) be suited to the habitat and area to be surveyed, (b) take into account the segment of the sandfly population to be sampled (species, sex and reproduction condition) and (c) yield specimens of appropriate condition for the study objectives (e.g. identification of species present, population genetics or vector implication). Methods for preservation and transportation of sandflies to the laboratory also depend on the objectives of a particular study and are described accordingly. PMID:10872855

  16. Sampling system and method

    DOEpatents

    Decker, David L; Lyles, Brad F; Purcell, Richard G; Hershey, Ronald Lee

    2014-05-20

    An apparatus and method for supporting a tubing bundle during installation or removal. The apparatus includes a clamp for securing the tubing bundle to an external wireline. The method includes deploying the tubing bundle and wireline together, The tubing bundle is periodically secured to the wireline using a clamp.

  17. Elaborating transition interface sampling methods

    SciTech Connect

    Erp, Titus S. van . E-mail: bolhuis@science.uva.nl

    2005-05-01

    We review two recently developed efficient methods for calculating rate constants of processes dominated by rare events in high-dimensional complex systems. The first is transition interface sampling (TIS), based on the measurement of effective fluxes through hypersurfaces in phase space. TIS improves efficiency with respect to standard transition path sampling (TPS) rate constant techniques, because it allows a variable path length and is less sensitive to recrossings. The second method is the partial path version of TIS. Developed for diffusive processes, it exploits the loss of long time correlation. We discuss the relation between the new techniques and the standard reactive flux methods in detail. Path sampling algorithms can suffer from ergodicity problems, and we introduce several new techniques to alleviate these problems, notably path swapping, stochastic configurational bias Monte Carlo shooting moves and order-parameter free path sampling. In addition, we give algorithms to calculate other interesting properties from path ensembles besides rate constants, such as activation energies and reaction mechanisms.

  18. A new calculation method adapted to the experimental conditions for determining samples γ-activities induced by 14 MeV neutrons

    NASA Astrophysics Data System (ADS)

    Rzama, A.; Erramli, H.; Misdaq, M. A.

    1994-09-01

    Induced gamma-activities of different disk shaped irradiated samples and standards with 14 MeV neutrons have been determined by using a Monte Carlo calculation method adapted to the experimental conditions. The self-absorption of the multienergetic emitted gamma rays has been taken into account in the final samples activities. The influence of the different activation parameters has been studied. Na, K, Cl and P contents in biological (red beet) samples have been determined.

  19. Active submarine volcano sampled

    USGS Publications Warehouse

    Taylor, B.

    1983-01-01

    On June 4, 1982, two full dredge hauls of fresh lava were recovered from the upper flanks of Kavachi submarine volcano, Solomon Islands, in the western Pacific Ocean, from the water depths of 1,200 and 2,700 feet. the shallower dredge site was within 0.5 mile of the active submarine vent shown at the surface by an area of slick water, probably caused by gas emissions. Kavachi is a composite stratovolcano that has been observed to erupt every year or two for at least the last 30 years (see photographs). An island formed in 1952, 1961, 1965, and 1978; but, in each case, it rapidly eroded below sea level. The latest eruption was observed by Solair pilots during the several weeks up to and including May 18, 1982. 

  20. A specific method for measurement of equine active myeloperoxidase in biological samples and in in vitro tests.

    PubMed

    Franck, Thierry; Kohnen, S; Deby-Dupont, G; Grulke, S; Deby, C; Serteyn, D

    2006-07-01

    An original method called SIEFED (specific immunological extraction followed by enzymatic detection) was developed for the specific detection of the activity of equine myeloperoxidase (MPO). The method consists of the extraction of MPO from aqueous solutions by immobilized anti-MPO antibodies followed by washing (to eliminate proteins and interfering molecules) and measurement of MPO activity using a detection system containing a fluorogenic substrate, hydrogen peroxide, and nitrite as reaction enhancer. The SIEFED technique was applied to study active MPO in horse biological fluids and the effects of 2 polyphenolic molecules, curcumin and resveratrol, on MPO activity. The detection limit of the SIEFED was 0.23 mU/ml. The SIEFED exhibited good precision with intra-assay and interassay coefficients of variation below 10% and 20%, respectively, for MPO activities ranging from 0.25 to 6.4 mU/ml. The activity of MPO was generally higher than 1 mU/ml in the fluids collected from horses with inflammatory diseases. Curcumin and resveratrol exerted a dose-dependent inhibition on MPO activity and, as they were removed before the enzymatic detection of MPO, the results suggest a direct drug-nzyme interaction or an enzyme structure modification by the drug. The SIEFED is a new tool that would be useful for specific detection of active MPO in complex media and for selection of MPO activity modulators.

  1. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, David R.

    1998-01-01

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis.

  2. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, D.R.

    1998-02-03

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis. 3 figs.

  3. Duplex sampling apparatus and method

    DOEpatents

    Brown, Paul E.; Lloyd, Robert

    1992-01-01

    An improved apparatus is provided for sampling a gaseous mixture and for measuring mixture components. The apparatus includes two sampling containers connected in series serving as a duplex sampling apparatus. The apparatus is adapted to independently determine the amounts of condensable and noncondensable gases in admixture from a single sample. More specifically, a first container includes a first port capable of selectively connecting to and disconnecting from a sample source and a second port capable of selectively connecting to and disconnecting from a second container. A second container also includes a first port capable of selectively connecting to and disconnecting from the second port of the first container and a second port capable of either selectively connecting to and disconnecting from a differential pressure source. By cooling a mixture sample in the first container, the condensable vapors form a liquid, leaving noncondensable gases either as free gases or dissolved in the liquid. The condensed liquid is heated to drive out dissolved noncondensable gases, and all the noncondensable gases are transferred to the second container. Then the first and second containers are separated from one another in order to separately determine the amount of noncondensable gases and the amount of condensable gases in the sample.

  4. A novel near-infrared spectroscopy and chemometrics method for rapid analysis of several chemical components and antioxidant activity of mint (Mentha haplocalyx Briq.) samples.

    PubMed

    Dong, Wenjiang; Ni, Yongnian; Kokot, Serge

    2014-01-01

    A novel near-infrared spectroscopy (NIRS) method has been researched and developed for the simultaneous analyses of the chemical components and associated properties of mint (Mentha haplocalyx Briq.) tea samples. The common analytes were: total polysaccharide content, total flavonoid content, total phenolic content, and total antioxidant activity. To resolve the NIRS data matrix for such analyses, least squares support vector machines was found to be the best chemometrics method for prediction, although it was closely followed by the radial basis function/partial least squares model. Interestingly, the commonly used partial least squares was unsatisfactory in this case. Additionally, principal component analysis and hierarchical cluster analysis were able to distinguish the mint samples according to their four geographical provinces of origin, and this was further facilitated with the use of the chemometrics classification methods-K-nearest neighbors, linear discriminant analysis, and partial least squares discriminant analysis. In general, given the potential savings with sampling and analysis time as well as with the costs of special analytical reagents required for the standard individual methods, NIRS offered a very attractive alternative for the simultaneous analysis of mint samples.

  5. Assessment of the neutron activation of a stainless steel sample in a Research Nuclear Reactor using the Monte Carlo method and CINDER'90

    NASA Astrophysics Data System (ADS)

    Lázaro, Ignacio; Ródenas, José; Marques, José G.; Gallardo, Sergio

    2014-06-01

    Materials in a nuclear reactor are activated by neutron irradiation. When they are withdrawn from the reactor and placed in some storage, the potential dose received by workers in the surrounding area must be taken into account. In previous papers, activation of control rods in a NPP with BWR and dose rates around the storage pool have been estimated using the MCNP5 code based on the Monte Carlo method. Models were validated comparing simulation results with experimental measurements. As the activation is mostly produced in stainless steel components of control rods the activation model can be also validated by means of experimental measurements on a stainless steel sample after being irradiated in a reactor. This has been done in the Portuguese Research Reactor at Instituto Tecnológico e Nuclear. The neutron activation has been calculated by two different methods, Monte Carlo and CINDER'90, and results have been compared. After irradiation, dose rates at the water surface of the reactor pool were measured, with the irradiated stainless steel sample submerged at different positions under water. Experimental measurements have been compared with simulation results using Monte Carlo. The comparison shows a good agreement confirming the validation of models.

  6. Apparatus and method for handheld sampling

    DOEpatents

    Staab, Torsten A.

    2005-09-20

    The present invention includes an apparatus, and corresponding method, for taking a sample. The apparatus is built around a frame designed to be held in at least one hand. A sample media is used to secure the sample. A sample media adapter for securing the sample media is operated by a trigger mechanism connectively attached within the frame to the sample media adapter.

  7. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, C.V.

    1991-02-05

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allows an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds. 11 figures.

  8. Soil sampling kit and a method of sampling therewith

    DOEpatents

    Thompson, Cyril V.

    1991-01-01

    A soil sampling device and a sample containment device for containing a soil sample is disclosed. In addition, a method for taking a soil sample using the soil sampling device and soil sample containment device to minimize the loss of any volatile organic compounds contained in the soil sample prior to analysis is disclosed. The soil sampling device comprises two close fitting, longitudinal tubular members of suitable length, the inner tube having the outward end closed. With the inner closed tube withdrawn a selected distance, the outer tube can be inserted into the ground or other similar soft material to withdraw a sample of material for examination. The inner closed end tube controls the volume of the sample taken and also serves to eject the sample. The soil sample containment device has a sealing member which is adapted to attach to an analytical apparatus which analyzes the volatile organic compounds contained in the sample. The soil sampling device in combination with the soil sample containment device allow an operator to obtain a soil sample containing volatile organic compounds and minimizing the loss of the volatile organic compounds prior to analysis of the soil sample for the volatile organic compounds.

  9. Characterization of Soil Samples of Enzyme Activity

    ERIC Educational Resources Information Center

    Freeland, P. W.

    1977-01-01

    Described are nine enzyme essays for distinguishing soil samples. Colorimetric methods are used to compare enzyme levels in soils from different sites. Each soil tested had its own spectrum of activity. Attention is drawn to applications of this technique in forensic science and in studies of soil fertility. (Author/AJ)

  10. Non-destructive elemental analysis of large meteorite samples by prompt gamma-ray neutron activation analysis with the internal mono-standard method.

    PubMed

    Latif, Sk A; Oura, Y; Ebihara, M; Nakahara, H

    2013-11-01

    Prompt gamma-ray neutron activation analysis (PGNAA) using the internal mono-standard method was tested for its applicability to analyzing large solid samples including irregularly shaped meteorite samples. For evaluating the accuracy and precision of the method, large quantities of the Geological Survey of Japan standardized rock powders (JB-1a, JG-1a, and JP-1) were analyzed and 12 elements (B, Na, Mg, Al, Cl, K, Ca, Ti, Mn, Fe, Sm, and Gd) were determined by using Si as an internal standard element. Analytical results were mostly in agreement with literature values within 10 %. The precision of the method was also shown to be within 10 % (1σ) for most of these elements. The analytical procedure was then applied to four stony meteorites (Allende, Kimble County, Leedey, Lake Labyrinth) and four iron meteorites (Canyon Diablo, Toluca (Mexico), Toluca (Xiquipilco), Squaw Creek) consisting of large chunks or single slabs. For stony meteorites, major elements (Mg, Al, Si, S, Ca, and Ni), minor elements (Na and Mn) and trace element (B, Cl, K, Ti, Co, and Sm) were determined with adequate accuracy. For iron meteorites, results for the Co and Ni mass fractions determined are all consistent with corresponding literature values. After the analysis, it was confirmed that the residual radioactivity remaining in the sample after PGNAA was very low and decreased down to the background level. This study shows that PGNAA with the internal mono-standard method is highly practical for determining the elemental composition of large, irregularly shaped solid samples including meteorites.

  11. Non-destructive elemental analysis of large meteorite samples by prompt gamma-ray neutron activation analysis with the internal mono-standard method.

    PubMed

    Latif, Sk A; Oura, Y; Ebihara, M; Nakahara, H

    2013-11-01

    Prompt gamma-ray neutron activation analysis (PGNAA) using the internal mono-standard method was tested for its applicability to analyzing large solid samples including irregularly shaped meteorite samples. For evaluating the accuracy and precision of the method, large quantities of the Geological Survey of Japan standardized rock powders (JB-1a, JG-1a, and JP-1) were analyzed and 12 elements (B, Na, Mg, Al, Cl, K, Ca, Ti, Mn, Fe, Sm, and Gd) were determined by using Si as an internal standard element. Analytical results were mostly in agreement with literature values within 10 %. The precision of the method was also shown to be within 10 % (1σ) for most of these elements. The analytical procedure was then applied to four stony meteorites (Allende, Kimble County, Leedey, Lake Labyrinth) and four iron meteorites (Canyon Diablo, Toluca (Mexico), Toluca (Xiquipilco), Squaw Creek) consisting of large chunks or single slabs. For stony meteorites, major elements (Mg, Al, Si, S, Ca, and Ni), minor elements (Na and Mn) and trace element (B, Cl, K, Ti, Co, and Sm) were determined with adequate accuracy. For iron meteorites, results for the Co and Ni mass fractions determined are all consistent with corresponding literature values. After the analysis, it was confirmed that the residual radioactivity remaining in the sample after PGNAA was very low and decreased down to the background level. This study shows that PGNAA with the internal mono-standard method is highly practical for determining the elemental composition of large, irregularly shaped solid samples including meteorites. PMID:24037616

  12. Duplex sampling apparatus and method

    SciTech Connect

    Brown, P.E.; Lloyd, R.

    1992-07-07

    This patent describes a method of measuring the condensable vapor content and the noncondensable gaseous content of a mixture of condensable vapors and noncondensable gases. It comprises collecting a quantity of a mixture of condensable vapors and noncondensable gases in a first container, cooling the first container whereby the condensable vapors in the mixture are condensed, transferring the noncondensable gases from the first container to a downstream second container, determining the quantity of condensable vapors retained in the first container, and measuring the pressure of noncondensable gases in the second container, measuring the temperature of noncondensable gases in the second container, thereby determining the quantity of noncondensable gases in the second container from the temperature, pressure and volume, using the ideal gas law: P{sub v} = nRT, whereby the ratio of condensable vapors to noncondensable gases in the mixture is determined.

  13. Subrandom methods for multidimensional nonuniform sampling.

    PubMed

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics.

  14. Subrandom methods for multidimensional nonuniform sampling

    NASA Astrophysics Data System (ADS)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics.

  15. Method and apparatus for data sampling

    DOEpatents

    Odell, Daniel M. C.

    1994-01-01

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium.

  16. Method and apparatus for data sampling

    DOEpatents

    Odell, D.M.C.

    1994-04-19

    A method and apparatus for sampling radiation detector outputs and determining event data from the collected samples is described. The method uses high speed sampling of the detector output, the conversion of the samples to digital values, and the discrimination of the digital values so that digital values representing detected events are determined. The high speed sampling and digital conversion is performed by an A/D sampler that samples the detector output at a rate high enough to produce numerous digital samples for each detected event. The digital discrimination identifies those digital samples that are not representative of detected events. The sampling and discrimination also provides for temporary or permanent storage, either serially or in parallel, to a digital storage medium. 6 figures.

  17. Mixed Methods Sampling: A Typology with Examples

    ERIC Educational Resources Information Center

    Teddlie, Charles; Yu, Fen

    2007-01-01

    This article presents a discussion of mixed methods (MM) sampling techniques. MM sampling involves combining well-established qualitative and quantitative techniques in creative ways to answer research questions posed by MM research designs. Several issues germane to MM sampling are presented including the differences between probability and…

  18. Determination of selected cardiovascular active compounds in environmental aquatic samples--Methods and results, a review of global publications from the last 10 years.

    PubMed

    Stankiewicz, Albert; Giebułtowicz, Joanna; Stankiewicz, Urszula; Wroczyński, Piotr; Nałęcz-Jawecki, Grzegorz

    2015-11-01

    In recent years cardiovascular diseases were the second most common cause of death worldwide. Therefore, the consumption of cardiovascular drugs is high, which might result in an increase of them in the environment. The major source of aquatic environmental contamination is still effluents of wastewater treatment plants (WWTPs). Unfortunately removal of cardiovascular active compounds and/or their metabolites in WWTP is still unsatisfactory. Among microbial and abiotic degradation of these compounds during wastewater processes, photolysis and photodegradation of cardiovascular drugs also play an important role. New formed compounds may be more toxic or retain the properties of parent compounds. Thus the main goal of this paper was to provide a detailed and comprehensive review of used analytical methods, coupled to liquid chromatography-tandem mass spectrometry, to determine the presence of cardiovascular compounds in surface waters as well as WTTPs effluents and influents. Exhaustive preparation for mass spectrometry detection and quantitation including samples pre-treatment, and the common problem of the matrix effect are thoroughly explored in this paper. Additionally, the article provides some hints in respect of recently noted problematic issue related to the availability of specific standards for the analysis of drug's metabolites. Furthermore, information concerning the metabolism of cardiovascular active compounds including differences in metabolism within enantiomers is described. This article also touches on the problems associated with environmental risk assessment due to the presence of cardiovasculars in the environment. The paper also tries to explain differences in concentrations among cardiovascular compounds between countries worldwide.

  19. Sample normalization methods in quantitative metabolomics.

    PubMed

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts.

  20. Dynamic Method for Identifying Collected Sample Mass

    NASA Technical Reports Server (NTRS)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  1. Photographic sampling: a photographic sampling method for mites on plants.

    PubMed

    Sircom, J

    2000-01-01

    A photographic sampling method for mites on plants was evaluated using Tetranychus urticae and Phytoseiulus persimilis on pepper plants. It was found to be 92% accurate for T. urticae eggs and 98% accurate for P. persimilis eggs at densities up to 45 eggs per cm2 for T. urticae, and up to 3 eggs per cm2 for P. persimilis. The motiles of the two species were not confused, nor were they confused with exuviae or other matter.

  2. Systems and methods for sample analysis

    SciTech Connect

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-10-20

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  3. Systems and methods for sample analysis

    DOEpatents

    Cooks, Robert Graham; Li, Guangtao; Li, Xin; Ouyang, Zheng

    2015-01-13

    The invention generally relates to systems and methods for sample analysis. In certain embodiments, the invention provides a system for analyzing a sample that includes a probe including a material connected to a high voltage source, a device for generating a heated gas, and a mass analyzer.

  4. Method and apparatus for sampling atmospheric mercury

    DOEpatents

    Trujillo, Patricio E.; Campbell, Evan E.; Eutsler, Bernard C.

    1976-01-20

    A method of simultaneously sampling particulate mercury, organic mercurial vapors, and metallic mercury vapor in the working and occupational environment and determining the amount of mercury derived from each such source in the sampled air. A known volume of air is passed through a sampling tube containing a filter for particulate mercury collection, a first adsorber for the selective adsorption of organic mercurial vapors, and a second adsorber for the adsorption of metallic mercury vapor. Carbon black molecular sieves are particularly useful as the selective adsorber for organic mercurial vapors. The amount of mercury adsorbed or collected in each section of the sampling tube is readily quantitatively determined by flameless atomic absorption spectrophotometry.

  5. DOE methods for evaluating environmental and waste management samples.

    SciTech Connect

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  6. Apparatus and method for time-integrated, active sampling of contaminants in fluids demonstrated by monitoring of hexavalent chromium in groundwater.

    PubMed

    Roll, Isaac B; Driver, Erin M; Halden, Rolf U

    2016-06-15

    Annual U.S. expenditures of $2B for site characterization invite the development of new technologies to improve data quality while reducing costs and minimizing uncertainty in groundwater monitoring. This work presents a new instrument for time-integrated sampling of environmental fluids using in situ solid-phase extraction (SPE). The In Situ Sampler (IS2) is an automated submersible device capable of extracting dissolved contaminants from water (100s-1000smL) over extended periods (hours to weeks), retaining the analytes, and rejecting the processed fluid. A field demonstration of the IS2 revealed 28-day average concentration of hexavalent chromium in a shallow aquifer affected by tidal stresses via sampling of groundwater as both liquid and sorbed composite samples, each obtained in triplicate. In situ SPE exhibited 75±6% recovery and an 8-fold improvement in reporting limit. Relative to use of conventional methods (100%), beneficial characteristics of the device and method included minimal hazardous material generation (2%), transportation cost (10%), and associated carbon footprint (2%). The IS2 is compatible with commercial SPE resins and standard extraction methods, and has been certified for more general use (i.e., inorganics and organics) by the Environmental Security Technology Certification Program (ESTCP) of the U.S. Department of Defense. PMID:26971208

  7. Apparatus and method for time-integrated, active sampling of contaminants in fluids demonstrated by monitoring of hexavalent chromium in groundwater.

    PubMed

    Roll, Isaac B; Driver, Erin M; Halden, Rolf U

    2016-06-15

    Annual U.S. expenditures of $2B for site characterization invite the development of new technologies to improve data quality while reducing costs and minimizing uncertainty in groundwater monitoring. This work presents a new instrument for time-integrated sampling of environmental fluids using in situ solid-phase extraction (SPE). The In Situ Sampler (IS2) is an automated submersible device capable of extracting dissolved contaminants from water (100s-1000smL) over extended periods (hours to weeks), retaining the analytes, and rejecting the processed fluid. A field demonstration of the IS2 revealed 28-day average concentration of hexavalent chromium in a shallow aquifer affected by tidal stresses via sampling of groundwater as both liquid and sorbed composite samples, each obtained in triplicate. In situ SPE exhibited 75±6% recovery and an 8-fold improvement in reporting limit. Relative to use of conventional methods (100%), beneficial characteristics of the device and method included minimal hazardous material generation (2%), transportation cost (10%), and associated carbon footprint (2%). The IS2 is compatible with commercial SPE resins and standard extraction methods, and has been certified for more general use (i.e., inorganics and organics) by the Environmental Security Technology Certification Program (ESTCP) of the U.S. Department of Defense.

  8. Bayesian individualization via sampling-based methods.

    PubMed

    Wakefield, J

    1996-02-01

    We consider the situation where we wish to adjust the dosage regimen of a patient based on (in general) sparse concentration measurements taken on-line. A Bayesian decision theory approach is taken which requires the specification of an appropriate prior distribution and loss function. A simple method for obtaining samples from the posterior distribution of the pharmacokinetic parameters of the patient is described. In general, these samples are used to obtain a Monte Carlo estimate of the expected loss which is then minimized with respect to the dosage regimen. Some special cases which yield analytic solutions are described. When the prior distribution is based on a population analysis then a method of accounting for the uncertainty in the population parameters is described. Two simulation studies showing how the methods work in practice are presented. PMID:8827585

  9. Actinide recovery method -- Large soil samples

    SciTech Connect

    Maxwell , S.L. III

    2000-04-25

    There is a need to measure actinides in environmental samples with lower and lower detection limits, requiring larger sample sizes. This analysis is adversely affected by sample-matrix interferences, which make analyzing soil samples above five-grams very difficult. A new Actinide-Recovery Method has been developed by the Savannah River Site Central Laboratory to preconcentrate actinides from large-soil samples. Diphonix Resin (Eichrom Industries), a 1994 R and D 100 winner, is used to preconcentrate the actinides from large soil samples, which are bound powerfully to the resin's diphosphonic acid groups. A rapid microwave-digestion technique is used to remove the actinides from the Diphonix Resin, which effectively eliminates interfering matrix components from the soil matrix. The microwave-digestion technique is more effective and less tedious than catalyzed hydrogen peroxide digestions of the resin or digestion of diphosphonic stripping agents such as HEDPA. After resin digestion, the actinides are recovered in a small volume of nitric acid which can be loaded onto small extraction chromatography columns, such as TEVA Resin, U-TEVA Resin or TRU Resin (Eichrom Industries). Small, selective extraction columns do not generate large volumes of liquid waste and provide consistent tracer recoveries after soil matrix elimination.

  10. A comparison of two ozone sampling methods

    SciTech Connect

    Downey, E.B.; Buchan, R.M.; Blehm, K.D.; Gunter, B.J.

    1983-05-01

    A study was conducted to compare the alkaline potassium iodide (AKI) impinger method versus a direct-reading chemiluminescent monitor for determining ozone concentrations. Comparisons were made in both a controlled laboratory situation and in the field during MIG welding. Laboratoy results indicated that the accuracy of the AKI procedure is affected by sample size. In the field, AKI impinger samples seemed to give very low estimations of the true ozone concentration. The direct-reading chemiluminescent monitor performed excellently in both the laboratory and field, and exhibited its merit as an industrial hygiene field instrument.

  11. Magnificent Ground Water Connection. [Sample Activities].

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC.

    Water conservation and usage is an important concept in science. This document, geared specifically to New England, provides many activities for protecting and discussing ground water situations. Sample activities for grades K-6 include: (1) All the Water in the World; (2) The Case of the Disappearing Water; (3) Deep Subjects--Wells and Ground…

  12. Actinide Recovery Method for Large Soil Samples

    SciTech Connect

    Maxwell, S.L. III; Nichols, S.

    1998-11-01

    A new Actinide Recovery Method has been developed by the Savannah River Site Central Laboratory to preconcentrate actinides in very large soil samples. Diphonix Resin(r) is used eliminate soil matrix interferences and preconcentrate actinides after soil leaching or soil fusion. A rapid microwave digestion technique is used to remove the actinides from the Diphonix Resin(r). After the resin digestion, the actinides are recovered in a small volume of nitric acid which can be easily loaded onto small extraction-chromatography columns, such as TEVA Resin(r), U-TEVA Resin(r) or TRU Resin(r) (Eichrom Industries). This method enables the application of small, selective extraction-columns to recover actinides from very large soil samples with high selectivity, consistent tracer recoveries and minimal liquid waste.

  13. Methods for Sampling of Airborne Viruses

    PubMed Central

    Verreault, Daniel; Moineau, Sylvain; Duchaine, Caroline

    2008-01-01

    Summary: To better understand the underlying mechanisms of aerovirology, accurate sampling of airborne viruses is fundamental. The sampling instruments commonly used in aerobiology have also been used to recover viruses suspended in the air. We reviewed over 100 papers to evaluate the methods currently used for viral aerosol sampling. Differentiating infections caused by direct contact from those caused by airborne dissemination can be a very demanding task given the wide variety of sources of viral aerosols. While epidemiological data can help to determine the source of the contamination, direct data obtained from air samples can provide very useful information for risk assessment purposes. Many types of samplers have been used over the years, including liquid impingers, solid impactors, filters, electrostatic precipitators, and many others. The efficiencies of these samplers depend on a variety of environmental and methodological factors that can affect the integrity of the virus structure. The aerodynamic size distribution of the aerosol also has a direct effect on sampler efficiency. Viral aerosols can be studied under controlled laboratory conditions, using biological or nonbiological tracers and surrogate viruses, which are also discussed in this review. Lastly, general recommendations are made regarding future studies on the sampling of airborne viruses. PMID:18772283

  14. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2006-08-01

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM, on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA, on the 5' end.

  15. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi,Shanavaz; Langlois, Richard G.; Venkateswaran, Kodumudi S.

    2011-07-05

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

  16. [Identification of hashish samples with inductively coupled high-frequency plasma emission spectrometry and neutron activation analysis and data handling with neuronal networks. 1. Methods for the quantitative determination of characteristic trace elements].

    PubMed

    Lahl, H; Henke, G

    1997-11-01

    Neutron activation analysis (NAA) and inductively coupled plasma emission spectrometry (ICP-AES) were used to quantify the relative contents of Fe, Sc, Ce, Pa, Cr, Co, respectively the absolute contents of Cr, Zn, Mn, Fe, Mg, Al, Cu, Ti, Ca, Sr in hashish samples, seized in different countries. The samples were processed after dry ashing by means of instrumental NAA and after wet mineralization by means of ICP-AES. For determination of the sampling and measurement errors, one of the samples was analyzed repeatedly with both methods. Classifying hashish samples with regard to concentration of certain elements could be done by artificial neural networks with a modified backpropagation algorithm. By this way, identity and non identity of one unknown sample with one of many different samples as data pool can be ascertained, on principle. PMID:9446107

  17. Field evaluation of a VOST sampling method

    SciTech Connect

    Jackson, M.D.; Johnson, L.D.; Fuerst, R.G.; McGaughey, J.F.; Bursey, J.T.; Merrill, R.G.

    1994-12-31

    The VOST (SW-846 Method 0030) specifies the use of Tenax{reg_sign} and a particular petroleum-based charcoal (SKC Lot 104, or its equivalent), that is no longer commercially available. In field evaluation studies of VOST methodology, a replacement petroleum-based charcoal has been used: candidate replacement sorbents for charcoal were studied, and Anasorb{reg_sign} 747, a carbon-based sorbent, was selected for field testing. The sampling train was modified to use only Anasorb{reg_sign} in the back tube and Tenax{reg_sign} in the two front tubes to avoid analytical difficulties associated with the analysis of the sequential bed back tube used in the standard VOST train. The standard (SW-846 Method 0030) and the modified VOST methods were evaluated at a chemical manufacturing facility using a quadruple probe system with quadruple trains. In this field test, known concentrations of the halogenated volatile organic compounds, that are listed in the Clean Air Act Amendments of 1990, Title 3, were introduced into the VOST train and the modified VOST train, using the same certified gas cylinder as a source of test compounds. Statistical tests of the comparability of methods were performed on a compound-by-compound basis. For most compounds, the VOST and modified VOST methods were found to be statistically equivalent.

  18. Competency-Based Adult Education Sample Activities.

    ERIC Educational Resources Information Center

    Dauzat, Sam V.; Bryant, Nerissa

    For use by adult basic education teachers, this curriculum guide is intended as a frame of reference for building a total instructional program designed around a competency-based and skill-based curriculum. The 104 sample activities are categorized under subheadings of the following topics: Occupational Knowledge, Health, Government and Law,…

  19. Method and apparatus for sampling low-yield wells

    DOEpatents

    Last, George V.; Lanigan, David C.

    2003-04-15

    An apparatus and method for collecting a sample from a low-yield well or perched aquifer includes a pump and a controller responsive to water level sensors for filling a sample reservoir. The controller activates the pump to fill the reservoir when the water level in the well reaches a high level as indicated by the sensor. The controller deactivates the pump when the water level reaches a lower level as indicated by the sensors. The pump continuously activates and deactivates the pump until the sample reservoir is filled with a desired volume, as indicated by a reservoir sensor. At the beginning of each activation cycle, the controller optionally can select to purge an initial quantity of water prior to filling the sample reservoir. The reservoir can be substantially devoid of air and the pump is a low volumetric flow rate pump. Both the pump and the reservoir can be located either inside or outside the well.

  20. Evaluation of activated carbon fiber filter for sampling of organochlorine pesticides in environmental water samples.

    PubMed

    Murayama, Hitoshi; Moriyama, Noboru; Mitobe, Hideko; Mukai, Hiroyuki; Takase, Yuuya; Shimizu, Ken ichi; Kitayama, Yoshie

    2003-08-01

    A simple method for quantitative analyses of organic chlorine pesticides (OCPs) in environmental water samples such as rainwater, river water and seawater using activated carbon fiber filters (ACFF) is described. ACFF was used as adsorbent to collect the chemicals in water samples. The collection of OCPs was completed almost for one day by stirring the mixture of the sample and the ACFF chips at room temperature. The adsorbed OCPs on the ACFF could be extracted easily with toluene-ethanol (4:1) mixed solvent. The purified extract by a florisil column chromatograph was followed by the analysis using high-resolution gas chromatograph/high-resolution mass spectrometer. Recoveries of OCPs spiked to actual samples such as rainwater, river water and seawater samples were approximately more than 80%, and the coefficients of variations were within 10%. This method was applied to the actual samples and was confirmed to be applicable for monitoring sub-ng/l level OCPs in environmental water samples.

  1. DOE methods for evaluating environmental and waste management samples

    SciTech Connect

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  2. Use of a novel radiometric method to assess the inhibitory effect of donepezil on acetylcholinesterase activity in minimally diluted tissue samples

    PubMed Central

    Kikuchi, Tatsuya; Okamura, Toshimitsu; Arai, Takuya; Obata, Takayuki; Fukushi, Kiyoshi; Irie, Toshiaki; Shiraishi, Tetsuya

    2010-01-01

    Background and purpose: Cholinesterase inhibitors have been widely used for the treatment of patients with dementia. Monitoring of the cholinesterase activity in the blood is used as an indicator of the effect of the cholinesterase inhibitors in the brain. The selective measurement of cholinesterase with low tissue dilution is preferred for accurate monitoring; however, the methods have not been established. Here, we investigated the effect of tissue dilution on the action of cholinesterase inhibitors using a novel radiometric method with selective substrates, N-[14C]methylpiperidin-4-yl acetate ([14C]MP4A) and (R)-N-[14C]methylpiperidin-3-yl butyrate ([14C]MP3B_R), for AChE and butyrylcholinesterase (BChE) respectively. Experimental approach: We investigated the kinetics of hydrolysis of [14C]-MP4A and [14C]-MP3B_R by cholinesterases, and evaluated the selectivity of [14C]MP4A and [14C]MP3B_R for human AChE and BChE, respectively, compared with traditional substrates. Then, IC50 values of cholinesterase inhibitors in minimally diluted and highly diluted tissues were measured with [14C]MP4A and [14C]MP3B_R. Key results: AChE and BChE activities were selectively measured as the first-order hydrolysis rates of [14C]-MP4A and [14C]MP3B_R respectively. The AChE selectivity of [14C]MP4A was an order of magnitude higher than traditional substrates used for the AChE assay. The IC50 values of specific AChE and BChE inhibitors, donepezil and ethopropazine, in 1.2-fold diluted human whole blood were much higher than those in 120-fold diluted blood. In addition, the IC50 values of donepezil in monkey brain were dramatically decreased as the tissue was diluted. Conclusions and implications: This method would effectively monitor the activity of cholinesterase inhibitors used for therapeutics, pesticides and chemical warfare agents. PMID:20401964

  3. System and Method for Isolation of Samples

    NASA Technical Reports Server (NTRS)

    Zhang, Ye (Inventor); Wu, Honglu (Inventor)

    2014-01-01

    Systems and methods for isolating samples are provided. The system comprises a first membrane and a second membrane disposed within an enclosure. First and second reservoirs can also be disposed within the enclosure and adapted to contain one or more reagents therein. A first valve can be disposed within the enclosure and in fluid communication with the first reservoir, the second reservoir, or both. The first valve can also be in fluid communication with the first or second membranes or both. The first valve can be adapted to selectively regulate the flow of the reagents from the first reservoir, through at least one of the first and second membranes, and into the second reservoir.

  4. Bacillus polymachus sp. nov., with a broad range of antibacterial activity, isolated from forest topsoil samples by using a modified culture method.

    PubMed

    Nguyen, Tuan Manh; Kim, Jaisoo

    2015-02-01

    A new, modified culture method that utilizes a transwell plate with a 0.4 µm pore-size microporous membrane was developed. This system allows only trace nutrients from the soil into the liquid culture through the microporous membrane. The method is a more powerful tool for the discovery of novel species from soils than are traditional methods. Such newly identified species could potentially produce useful metabolites. A bacterial strain, T515(T), was isolated using this modified culture method. Growth of strain T515(T) occurred at pH 4-9 in a temperature range between 20 °C and 40 °C and in the presence of 0-2 % (w/v) NaCl on R2A agar. Colonies on the agar plates were tiny, white, and convex after 5 days incubation at 28 °C. Comparative analysis of the nearly full-length 16S rRNA gene sequence of strain T515(T) revealed close pairwise similarity with species of the genus Bacillus, and strain T515(T) was most closely related to Bacillus panaciterrae Gsoil 1517(T) (96.7 %) and Bacillus funiculus NAF001(T) (96.0 %). The major quinone of strain T515(T) was menaquinone-7 (MK-7) and the major fatty acids were iso-C15 : 0 (45.5 %), anteiso-C15 : 0 (23.2 %) and C16 : 0 (10.9 %). The predominant polar lipids were diphosphatidylglycerol, phosphatidylglycerol and phosphatidylethanolamine. Strain T515(T) was sensitive to streptomycin and tetracycline, but resistant to rifampicin (0.125 µg ml(-1)), ampicillin (0.5 µg ml(-1)) and chloramphenicol (1 µg ml(-1)). The strain showed antimicrobial activities against the six strains tested: Bacillus subtilis KEMB 51201-001, Staphylococcus aureus KEMB 4659, Pseudomonas aeruginosa KACC 10185, Staphylococcus epidermidis KACC 13234, Paenibacillus larvae KACC 14031 and Escherichia coli KEMB 212-234. Based on these results, strain T515(T) represents a novel species of the genus Bacillus with the proposed name, Bacillus polymachus sp. nov. The type strain is T515(T) ( = KEMB 9005-168(T) = KACC 18242(T) = NBRC 110614(T)).

  5. Bacillus polymachus sp. nov., with a broad range of antibacterial activity, isolated from forest topsoil samples by using a modified culture method.

    PubMed

    Nguyen, Tuan Manh; Kim, Jaisoo

    2015-02-01

    A new, modified culture method that utilizes a transwell plate with a 0.4 µm pore-size microporous membrane was developed. This system allows only trace nutrients from the soil into the liquid culture through the microporous membrane. The method is a more powerful tool for the discovery of novel species from soils than are traditional methods. Such newly identified species could potentially produce useful metabolites. A bacterial strain, T515(T), was isolated using this modified culture method. Growth of strain T515(T) occurred at pH 4-9 in a temperature range between 20 °C and 40 °C and in the presence of 0-2 % (w/v) NaCl on R2A agar. Colonies on the agar plates were tiny, white, and convex after 5 days incubation at 28 °C. Comparative analysis of the nearly full-length 16S rRNA gene sequence of strain T515(T) revealed close pairwise similarity with species of the genus Bacillus, and strain T515(T) was most closely related to Bacillus panaciterrae Gsoil 1517(T) (96.7 %) and Bacillus funiculus NAF001(T) (96.0 %). The major quinone of strain T515(T) was menaquinone-7 (MK-7) and the major fatty acids were iso-C15 : 0 (45.5 %), anteiso-C15 : 0 (23.2 %) and C16 : 0 (10.9 %). The predominant polar lipids were diphosphatidylglycerol, phosphatidylglycerol and phosphatidylethanolamine. Strain T515(T) was sensitive to streptomycin and tetracycline, but resistant to rifampicin (0.125 µg ml(-1)), ampicillin (0.5 µg ml(-1)) and chloramphenicol (1 µg ml(-1)). The strain showed antimicrobial activities against the six strains tested: Bacillus subtilis KEMB 51201-001, Staphylococcus aureus KEMB 4659, Pseudomonas aeruginosa KACC 10185, Staphylococcus epidermidis KACC 13234, Paenibacillus larvae KACC 14031 and Escherichia coli KEMB 212-234. Based on these results, strain T515(T) represents a novel species of the genus Bacillus with the proposed name, Bacillus polymachus sp. nov. The type strain is T515(T) ( = KEMB 9005-168(T) = KACC 18242(T) = NBRC 110614(T)). PMID

  6. Improved mesh based photon sampling techniques for neutron activation analysis

    SciTech Connect

    Relson, E.; Wilson, P. P. H.; Biondo, E. D.

    2013-07-01

    The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

  7. Summary of activities. [Mars surface sampling

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the

  8. Well fluid isolation and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. A seal may be positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Purged well fluid is stored in a riser above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  9. The experience sampling method: Investigating students' affective experience

    NASA Astrophysics Data System (ADS)

    Nissen, Jayson M.; Stetzer, MacKenzie R.; Shemwell, Jonathan T.

    2013-01-01

    Improving non-cognitive outcomes such as attitudes, efficacy, and persistence in physics courses is an important goal of physics education. This investigation implemented an in-the-moment surveying technique called the Experience Sampling Method (ESM) [1] to measure students' affective experience in physics. Measurements included: self-efficacy, cognitive efficiency, activation, intrinsic motivation, and affect. Data are presented that show contrasts in students' experiences (e.g., in physics vs. non-physics courses).

  10. System and method for extracting a sample from a surface

    DOEpatents

    Van Berkel, Gary; Covey, Thomas

    2015-06-23

    A system and method is disclosed for extracting a sample from a sample surface. A sample is provided and a sample surface receives the sample which is deposited on the sample surface. A hydrophobic material is applied to the sample surface, and one or more devices are configured to dispense a liquid on the sample, the liquid dissolving the sample to form a dissolved sample material, and the one or more devices are configured to extract the dissolved sample material from the sample surface.

  11. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Service, Dairy Programs, or Official Methods of Analysis of the Association of Analytical Chemists or... 7 Agriculture 3 2011-01-01 2011-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods...

  12. Potassium bromide method of infrared sampling

    USGS Publications Warehouse

    Milkey, R.G.

    1958-01-01

    In the preparation of potassium bromide pressed windows for use in the infrared analysis of solids, severe grinding of the potassium bromide powder may produce strong absorption bands that could interfere seriously with the spectra of the sample. These absorption bands appear to be due to some crystal alteration of the potassium bromide as a result of the grinding process. They were less apt to occur when the coarser powder, which had received a relatively gentle grinding, was used. Window blanks prepared from the coarser powders showed smaller adsorbed water peaks and generally higher over-all transmittance readings than windows pressed from the very fine powders.

  13. Field evaluation of endotoxin air sampling assay methods.

    PubMed

    Thorne, P S; Reynolds, S J; Milton, D K; Bloebaum, P D; Zhang, X; Whitten, P; Burmeister, L F

    1997-11-01

    This study tested the importance of filter media, extraction and assay protocol, and bioaerosol source on the determination of endotoxin under field conditions in swine and poultry confinement buildings. Multiple simultaneous air samples were collected using glass fiber (GF) and polycarbonate (PC) filters, and these were assayed using two methods in two separate laboratories: an endpoint chromogenic Limulus amebocyte lysate (LAL) assay (QCL) performed in water and a kinetic chromogenic LAL assay (KQCL) performed in buffer with resistant-parallel line estimation analysis (KLARE). In addition, two aqueous filter extraction methods were compared in the QCL assay: 120 min extraction at 22 degrees C with vigorous shaking and 30 min extraction at 68 degrees C with gentle rocking. These extraction methods yielded endotoxin activities that were not significantly different and were very highly correlated. Reproducibility of endotoxin determinations from duplicate air sampling filters was very high (Cronbach alpha all > 0.94). When analyzed by the QCL method GF filters yielded significantly higher endotoxin activity than PC filters. QCL and KLARE methods gave similar estimates for endotoxin activity from PC filters; however, GF filters analyzed by the QCL method yielded significantly higher endotoxin activity estimates, suggesting enhancement of the QCL assay or inhibition of the KLARE asay with GF filters. Correlation between QCL-GF and QCL-PC was high (r = 0.98) while that between KLARE-GF and KLARE-PC was moderate (r = 0.68). Analysis of variance demonstrated that assay methodology, filter-type, barn-type, and interactions between assay and filter-type and between assay and barn-type were important factors influencing endotoxin exposure assessment.

  14. A Comparison of EPI Sampling, Probability Sampling, and Compact Segment Sampling Methods for Micro and Small Enterprises

    PubMed Central

    Chao, Li-Wei; Szrek, Helena; Peltzer, Karl; Ramlagan, Shandir; Fleming, Peter; Leite, Rui; Magerman, Jesswill; Ngwenya, Godfrey B.; Pereira, Nuno Sousa; Behrman, Jere

    2011-01-01

    Finding an efficient method for sampling micro- and small-enterprises (MSEs) for research and statistical reporting purposes is a challenge in developing countries, where registries of MSEs are often nonexistent or outdated. This lack of a sampling frame creates an obstacle in finding a representative sample of MSEs. This study uses computer simulations to draw samples from a census of businesses and non-businesses in the Tshwane Municipality of South Africa, using three different sampling methods: the traditional probability sampling method, the compact segment sampling method, and the World Health Organization’s Expanded Programme on Immunization (EPI) sampling method. Three mechanisms by which the methods could differ are tested, the proximity selection of respondents, the at-home selection of respondents, and the use of inaccurate probability weights. The results highlight the importance of revisits and accurate probability weights, but the lesser effect of proximity selection on the samples’ statistical properties. PMID:22582004

  15. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    SciTech Connect

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  16. A method for sampling waste corn

    USGS Publications Warehouse

    Frederick, R.B.; Klaas, E.E.; Baldassarre, G.A.; Reinecke, K.J.

    1984-01-01

    Corn had become one of the most important wildlife food in the United States. It is eaten by a wide variety of animals, including white-tailed deer (Odocoileus virginianus ), raccoon (Procyon lotor ), ring-necked pheasant (Phasianus colchicus , wild turkey (Meleagris gallopavo ), and many species of aquatic birds. Damage to unharvested crops had been documented, but many birds and mammals eat waste grain after harvest and do not conflict with agriculture. A good method for measuring waste-corn availability can be essential to studies concerning food density and food and feeding habits of field-feeding wildlife. Previous methods were developed primarily for approximating losses due to harvest machinery. In this paper, a method is described for estimating the amount of waste corn potentially available to wildlife. Detection of temporal changes in food availability and differences caused by agricultural operations (e.g., recently harvested stubble fields vs. plowed fields) are discussed.

  17. Evaluation of Sampling Methods and Development of Sample Plans for Estimating Predator Densities in Cotton

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The cost-reliability of five sampling methods (visual search, drop cloth, beat bucket, shake bucket and sweep net) was determined for predatory arthropods on cotton plants. The beat bucket sample method was the most cost-reliable while the visual sample method was the least cost-reliable. The beat ...

  18. Modified electrokinetic sample injection method in chromatography and electrophoresis analysis

    DOEpatents

    Davidson, J. Courtney; Balch, Joseph W.

    2001-01-01

    A sample injection method for horizontal configured multiple chromatography or electrophoresis units, each containing a number of separation/analysis channels, that enables efficient introduction of analyte samples. This method for loading when taken in conjunction with horizontal microchannels allows much reduced sample volumes and a means of sample stacking to greatly reduce the concentration of the sample. This reduction in the amount of sample can lead to great cost savings in sample preparation, particularly in massively parallel applications such as DNA sequencing. The essence of this method is in preparation of the input of the separation channel, the physical sample introduction, and subsequent removal of excess material. By this method, sample volumes of 100 nanoliter to 2 microliters have been used successfully, compared to the typical 5 microliters of sample required by the prior separation/analysis method.

  19. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Marketing Service, Dairy Programs, or the Official Methods of Analysis of the Association of Official... 7 Agriculture 3 2011-01-01 2011-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable...

  20. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  1. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA,...

  2. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  3. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural...

  4. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Representative Sampling Methods I...—Representative Sampling Methods The methods and equipment used for sampling waste materials will vary with the... Crushed or powdered material—ASTM Standard D346-75 Soil or rock-like material—ASTM Standard D420-69...

  5. Batch Mode Active Sampling based on Marginal Probability Distribution Matching.

    PubMed

    Chattopadhyay, Rita; Wang, Zheng; Fan, Wei; Davidson, Ian; Panchanathan, Sethuraman; Ye, Jieping

    2012-01-01

    Active Learning is a machine learning and data mining technique that selects the most informative samples for labeling and uses them as training data; it is especially useful when there are large amount of unlabeled data and labeling them is expensive. Recently, batch-mode active learning, where a set of samples are selected concurrently for labeling, based on their collective merit, has attracted a lot of attention. The objective of batch-mode active learning is to select a set of informative samples so that a classifier learned on these samples has good generalization performance on the unlabeled data. Most of the existing batch-mode active learning methodologies try to achieve this by selecting samples based on varied criteria. In this paper we propose a novel criterion which achieves good generalization performance of a classifier by specifically selecting a set of query samples that minimizes the difference in distribution between the labeled and the unlabeled data, after annotation. We explicitly measure this difference based on all candidate subsets of the unlabeled data and select the best subset. The proposed objective is an NP-hard integer programming optimization problem. We provide two optimization techniques to solve this problem. In the first one, the problem is transformed into a convex quadratic programming problem and in the second method the problem is transformed into a linear programming problem. Our empirical studies using publicly available UCI datasets and a biomedical image dataset demonstrate the effectiveness of the proposed approach in comparison with the state-of-the-art batch-mode active learning methods. We also present two extensions of the proposed approach, which incorporate uncertainty of the predicted labels of the unlabeled data and transfer learning in the proposed formulation. Our empirical studies on UCI datasets show that incorporation of uncertainty information improves performance at later iterations while our studies on 20

  6. Microfluidic DNA sample preparation method and device

    DOEpatents

    Krulevitch, Peter A.; Miles, Robin R.; Wang, Xiao-Bo; Mariella, Raymond P.; Gascoyne, Peter R. C.; Balch, Joseph W.

    2002-01-01

    Manipulation of DNA molecules in solution has become an essential aspect of genetic analyses used for biomedical assays, the identification of hazardous bacterial agents, and in decoding the human genome. Currently, most of the steps involved in preparing a DNA sample for analysis are performed manually and are time, labor, and equipment intensive. These steps include extraction of the DNA from spores or cells, separation of the DNA from other particles and molecules in the solution (e.g. dust, smoke, cell/spore debris, and proteins), and separation of the DNA itself into strands of specific lengths. Dielectrophoresis (DEP), a phenomenon whereby polarizable particles move in response to a gradient in electric field, can be used to manipulate and separate DNA in an automated fashion, considerably reducing the time and expense involved in DNA analyses, as well as allowing for the miniaturization of DNA analysis instruments. These applications include direct transport of DNA, trapping of DNA to allow for its separation from other particles or molecules in the solution, and the separation of DNA into strands of varying lengths.

  7. Sample storage for soil enzyme activity and bacterial community profiles.

    PubMed

    Wallenius, K; Rita, H; Simpanen, S; Mikkonen, A; Niemi, R M

    2010-04-01

    Storage of samples is often an unavoidable step in environmental data collection, since available analytical capacity seldom permits immediate processing of large sample sets needed for representative data. In microbiological soil studies, sample pretreatments may have a strong influence on measurement results, and thus careful consideration is required in the selection of storage conditions. The aim of this study was to investigate the suitability of prolonged (up to 16 weeks) frozen or air-dried storage for divergent soil materials. The samples selected to this study were mineral soil (clay loam) from an agricultural field, humus from a pine forest and compost from a municipal sewage sludge composting field. The measured microbiological parameters included functional profiling with ten different hydrolysing enzyme activities determined by artificial fluorogenic substrates, and structural profiling with bacterial 16S rDNA community fingerprints by amplicon length heterogeneity analysis (LH-PCR). Storage of samples affected the observed fluorescence intensity of the enzyme assay's fluorophor standards dissolved in soil suspension. The impact was highly dependent on the soil matrix and storage method, making it important to use separate standardisation for each combination of matrix type, storage method and time. Freezing proved to be a better storage method than air-drying for all the matrices and enzyme activities studied. The effect of freezing on the enzyme activities was small (<20%) in clay loam and forest humus and moderate (generally 20-30%) in compost. The most dramatic decreases (>50%) in activity were observed in compost after air-drying. The bacterial LH-PCR community fingerprints were unaffected by frozen storage in all matrices. The effect of storage treatments was tested using a new statistical method based on showing similarity rather than difference of results.

  8. Method for sampling sub-micron particles

    DOEpatents

    Gay, Don D.; McMillan, William G.

    1985-01-01

    Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.

  9. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W [West Richland, WA; Wise, Barry M [Manson, WA

    2002-01-01

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  10. Methods for characterizing, classifying, and identifying unknowns in samples

    DOEpatents

    Grate, Jay W.; Wise, Barry M.

    2003-08-12

    Disclosed is a method for taking the data generated from an array of responses from a multichannel instrument, and determining the characteristics of a chemical in the sample without the necessity of calibrating or training the instrument with known samples containing the same chemical. The characteristics determined by the method are then used to classify and identify the chemical in the sample. The method can also be used to quantify the concentration of the chemical in the sample.

  11. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    PubMed

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  12. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  13. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  14. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  15. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  16. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  17. 7 CFR 29.110 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling...

  18. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  19. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 2 2012-04-01 2012-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling....

  20. Artifact free denuder method for sampling of carbonaceous aerosols

    NASA Astrophysics Data System (ADS)

    Mikuška, P.; Vecera, Z.; Broškovicová, A.

    2003-04-01

    Over the past decade, a growing attention has been focused on the carbonaceous aerosols. Although they may account for 30--60% of the total fine aerosol mass, their concentration and formation mechanisms are not well understood, particularly in comparison with major fine particle inorganic species. The deficiency in knowledge of carbonaceous aerosols results from their complexity and because of problems associated with their collection. Conventional sampling techniques of the carbonaceous aerosols, which utilize filters/backup adsorbents suffer from sampling artefacts. Positive artifacts are mainly due to adsorption of gas-phase organic compounds by the filter material or by the already collected particles, whereas negative artifacts arise from the volatilisation of already collected organic compounds from the filter. Furthermore, in the course of the sampling, the composition of the collected organic compounds may be modified by oxidants (O_3, NO_2, PAN, peroxides) that are present in the air passing through the sampler. It is clear that new, artifact free, method for sampling of carbonaceous aerosols is needed. A combination of a diffusion denuder and a filter in series is very promising in this respect. The denuder is expected to collect gaseous oxidants and gas-phase organic compounds from sample air stream prior to collection of aerosol particles on filters, and eliminate thus both positive and negative sampling artifacts for carbonaceous aerosols. This combination is subject of the presentation. Several designs of diffusion denuders (cylindrical, annular, parallel plate, multi-channel) in combination with various types of wall coatings (dry, liquid) were examined. Special attention was given to preservation of the long-term collection efficiency. Different adsorbents (activated charcoal, molecular sieve, porous polymers) and sorbents coated with various chemical reagents (KI, Na_2SO_3, MnO_2, ascorbic acid) or chromatographic stationary phases (silicon oils

  1. Photoacoustic sample vessel and method of elevated pressure operation

    DOEpatents

    Autrey, Tom; Yonker, Clement R.

    2004-05-04

    An improved photoacoustic vessel and method of photoacoustic analysis. The photoacoustic sample vessel comprises an acoustic detector, an acoustic couplant, and an acoustic coupler having a chamber for holding the acoustic couplant and a sample. The acoustic couplant is selected from the group consisting of liquid, solid, and combinations thereof. Passing electromagnetic energy through the sample generates an acoustic signal within the sample, whereby the acoustic signal propagates through the sample to and through the acoustic couplant to the acoustic detector.

  2. Systems and methods for self-synchronized digital sampling

    NASA Technical Reports Server (NTRS)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  3. A method for selecting training samples based on camera response

    NASA Astrophysics Data System (ADS)

    Zhang, Leihong; Li, Bei; Pan, Zilan; Liang, Dong; Kang, Yi; Zhang, Dawei; Ma, Xiuhua

    2016-09-01

    In the process of spectral reflectance reconstruction, sample selection plays an important role in the accuracy of the constructed model and in reconstruction effects. In this paper, a method for training sample selection based on camera response is proposed. It has been proved that the camera response value has a close correlation with the spectral reflectance. Consequently, in this paper we adopt the technique of drawing a sphere in camera response value space to select the training samples which have a higher correlation with the test samples. In addition, the Wiener estimation method is used to reconstruct the spectral reflectance. Finally, we find that the method of sample selection based on camera response value has the smallest color difference and root mean square error after reconstruction compared to the method using the full set of Munsell color charts, the Mohammadi training sample selection method, and the stratified sampling method. Moreover, the goodness of fit coefficient of this method is also the highest among the four sample selection methods. Taking all the factors mentioned above into consideration, the method of training sample selection based on camera response value enhances the reconstruction accuracy from both the colorimetric and spectral perspectives.

  4. Sampling bee communities using pan traps: alternative methods increase sample size

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  5. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  6. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    PubMed

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis. PMID:26525264

  7. Methods for sampling and inorganic analysis of coal

    USGS Publications Warehouse

    Golightly, D. W.; Simon, Frederick Otto

    1989-01-01

    Methods used by the U.S. Geological Survey for the sampling, comminution, and inorganic analysis of coal are summarized in this bulletin. Details, capabilities, and limitations of the methods are presented.

  8. In-depth analysis of sampling optimization methods

    NASA Astrophysics Data System (ADS)

    Lee, Honggoo; Han, Sangjun; Kim, Myoungsoo; Habets, Boris; Buhl, Stefan; Guhlemann, Steffen; Rößiger, Martin; Bellmann, Enrico; Kim, Seop

    2016-03-01

    High order overlay and alignment models require good coverage of overlay or alignment marks on the wafer. But dense sampling plans are not possible for throughput reasons. Therefore, sampling plan optimization has become a key issue. We analyze the different methods for sampling optimization and discuss the different knobs to fine-tune the methods to constraints of high volume manufacturing. We propose a method to judge sampling plan quality with respect to overlay performance, run-to-run stability and dispositioning criteria using a number of use cases from the most advanced lithography processes.

  9. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    2001-01-01

    A method and apparatus for imaging a sample are provided. An electromagnetic radiation source generates excitation radiation which is sized by excitation optics to a line. The line is directed at a sample resting on a support and excites a plurality of regions on the sample. Collection optics collect response radiation reflected from the sample I and image the reflected radiation. A detector senses the reflected radiation and is positioned to permit discrimination between radiation reflected from a certain focal plane in the sample and certain other planes within the sample.

  10. Rapid method for sampling metals for materials identification

    NASA Technical Reports Server (NTRS)

    Higgins, L. E.

    1971-01-01

    Nondamaging process similar to electrochemical machining is useful in obtaining metal samples from places inaccessible to conventional sampling methods or where methods would be hazardous or contaminating to specimens. Process applies to industries where metals or metal alloys play a vital role.

  11. Engineering Study of 500 ML Sample Bottle Transportation Methods

    SciTech Connect

    BOGER, R.M.

    1999-08-25

    This engineering study reviews and evaluates all available methods for transportation of 500-mL grab sample bottles, reviews and evaluates transportation requirements and schedules and analyzes and recommends the most cost-effective method for transporting 500-mL grab sample bottles.

  12. GROUND WATER PURGING AND SAMPLING METHODS: HISTORY VS. HYSTERIA

    EPA Science Inventory

    It has been over 10 years since the low-flow ground water purging and sampling method was initially reported in the literature. The method grew from the recognition that well purging was necessary to collect representative samples, bailers could not achieve well purging, and high...

  13. A method and fortran program for quantitative sampling in paleontology

    USGS Publications Warehouse

    Tipper, J.C.

    1976-01-01

    The Unit Sampling Method is a binomial sampling method applicable to the study of fauna preserved in rocks too well cemented to be disaggregated. Preliminary estimates of the probability of detecting each group in a single sampling unit can be converted to estimates of the group's volumetric abundance by means of correction curves obtained by a computer simulation technique. This paper describes the technique and gives the FORTRAN program. ?? 1976.

  14. A Mixed Methods Sampling Methodology for a Multisite Case Study

    ERIC Educational Resources Information Center

    Sharp, Julia L.; Mobley, Catherine; Hammond, Cathy; Withington, Cairen; Drew, Sam; Stringfield, Sam; Stipanovic, Natalie

    2012-01-01

    The flexibility of mixed methods research strategies makes such approaches especially suitable for multisite case studies. Yet the utilization of mixed methods to select sites for these studies is rarely reported. The authors describe their pragmatic mixed methods approach to select a sample for their multisite mixed methods case study of a…

  15. Comparison of uranium determination in some Syrian geologic samples using three reactor based methods

    PubMed

    Jubeli

    2000-04-01

    A set of 25 samples of soil, sediments, carbonate and phosphate rocks from Syria were analysed for uranium, using three reactor based methods; instrumental neutron activation analysis (INAA), delayed neutron counting (DNC) and one cycle of irradiation utilizing the cyclic activation system (CAS). Although the three methods are capable of irradiation samples, the last method is the least established for U determination in rocks. The measurements obtained by the three methods are compared. The results show good agreement, with a distinct linear relationship and significant positive correlation coefficients. It was concluded that the CAS method could reliably be used to rapidly determine uranium in geological samples. PMID:10800739

  16. Application of the SAMR method to high magnetostrictive samples

    NASA Astrophysics Data System (ADS)

    Sanchez, P.; Lopez, E.; Trujillo, M. C. Sanchez; Aroca, C.

    1988-12-01

    Magnetostriction measurement by using the small angle magnetization rotation method (SAMR) has been performed in high magnetostrictive amorphous samples. To apply the SAMR method to these samples, a theoritical model about the influence of the internal stresses and magnetization distribution has been proposed. The dependence of the magnetostriction, λ s, with the temperature and applied stress was measured in as-cast and in different annealed samples. In the as-cast samples the existence of a stray field and a dependence of λ s with the applied stress has been observed.

  17. Method for using polarization gating to measure a scattering sample

    DOEpatents

    Baba, Justin S.

    2015-08-04

    Described herein are systems, devices, and methods facilitating optical characterization of scattering samples. A polarized optical beam can be directed to pass through a sample to be tested. The optical beam exiting the sample can then be analyzed to determine its degree of polarization, from which other properties of the sample can be determined. In some cases, an apparatus can include a source of an optical beam, an input polarizer, a sample, an output polarizer, and a photodetector. In some cases, a signal from a photodetector can be processed through attenuation, variable offset, and variable gain.

  18. Interval sampling methods and measurement error: a computer simulation.

    PubMed

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments.

  19. [Recent advances in sample preparation methods of plant hormones].

    PubMed

    Wu, Qian; Wang, Lus; Wu, Dapeng; Duan, Chunfeng; Guan, Yafeng

    2014-04-01

    Plant hormones are a group of naturally occurring trace substances which play a crucial role in controlling the plant development, growth and environment response. With the development of the chromatography and mass spectroscopy technique, chromatographic analytical method has become a widely used way for plant hormone analysis. Among the steps of chromatographic analysis, sample preparation is undoubtedly the most vital one. Thus, a highly selective and efficient sample preparation method is critical for accurate identification and quantification of phytohormones. For the three major kinds of plant hormones including acidic plant hormones & basic plant hormones, brassinosteroids and plant polypeptides, the sample preparation methods are reviewed in sequence especially the recently developed methods. The review includes novel methods, devices, extractive materials and derivative reagents for sample preparation of phytohormones analysis. Especially, some related works of our group are included. At last, the future developments in this field are also prospected.

  20. A random spatial sampling method in a rural developing nation

    PubMed Central

    2014-01-01

    Background Nonrandom sampling of populations in developing nations has limitations and can inaccurately estimate health phenomena, especially among hard-to-reach populations such as rural residents. However, random sampling of rural populations in developing nations can be challenged by incomplete enumeration of the base population. Methods We describe a stratified random sampling method using geographical information system (GIS) software and global positioning system (GPS) technology for application in a health survey in a rural region of Guatemala, as well as a qualitative study of the enumeration process. Results This method offers an alternative sampling technique that could reduce opportunities for bias in household selection compared to cluster methods. However, its use is subject to issues surrounding survey preparation, technological limitations and in-the-field household selection. Application of this method in remote areas will raise challenges surrounding the boundary delineation process, use and translation of satellite imagery between GIS and GPS, and household selection at each survey point in varying field conditions. This method favors household selection in denser urban areas and in new residential developments. Conclusions Random spatial sampling methodology can be used to survey a random sample of population in a remote region of a developing nation. Although this method should be further validated and compared with more established methods to determine its utility in social survey applications, it shows promise for use in developing nations with resource-challenged environments where detailed geographic and human census data are less available. PMID:24716473

  1. Method and sample spinning apparatus for measuring the NMR spectrum of an orientationally disordered sample

    DOEpatents

    Pines, Alexander; Samoson, Ago

    1990-01-01

    An improved NMR apparatus and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise orientationally disordered samples. The apparatus spins the sample about an axis. The angle of the axis is mechanically varied such that the time average of two or more Legendre polynomials are zero.

  2. Sampling and Measurement Error in Faculty Activity and Effort Reporting

    ERIC Educational Resources Information Center

    Lee, Edgar; Kutina, Kenneth L.

    1974-01-01

    Evaluates a stratified sampling method developed at the Case Western Reserve University School of Medicine to estimate mean faculty effort devoted to programs from randomly selected faculty samples over three consecutive years. (Author/PG)

  3. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  4. Nominal Weights Mean Equating: A Method for Very Small Samples

    ERIC Educational Resources Information Center

    Babcock, Ben; Albano, Anthony; Raymond, Mark

    2012-01-01

    The authors introduced nominal weights mean equating, a simplified version of Tucker equating, as an alternative for dealing with very small samples. The authors then conducted three simulation studies to compare nominal weights mean equating to six other equating methods under the nonequivalent groups anchor test design with sample sizes of 20,…

  5. Isolation of Legionella from water samples using various culture methods.

    PubMed

    Kusnetsov, J M; Jousimies-Somer, H R; Nevalainen, A I; Martikainen, P J

    1994-02-01

    The efficacy of a non-selective medium and two selective media were compared for the isolation of legionellas from water samples. The effect of acid wash treatment for decontamination of the water samples on the isolation frequency of legionellas was also studied. The 236 samples were taken from cooling, humidifying and drinking water systems; 21% were legionella-positive when inoculated directly on modified Wadowsky-Yee (MWY) medium and 26% were positive when concentrated (x 200) before cultivation on MWY or CCVC media. Inoculation on MWY medium after concentration followed by decontamination by the acid-wash technique gave the highest isolation frequency (31%). The lowest frequency (8%) was found with the non-selective BCYE alpha medium. An isolation frequency of 28% was achieved with the BCYE alpha medium after concentration and acid-wash treatment of the samples. Forty per cent of the samples were positive for legionellas when the results from all the culture methods were combined. Not all the legionella-positive samples were identified by a single culture method. Ninety-three of the 95 positive samples were detected with the two best combinations of three culture methods. The best culture method for detecting legionellas depended on the source of the water sample. Some water quality characteristics, like temperature and organic matter content, affected the isolation frequency of Legionella spp.

  6. Passive sampling methods for contaminated sediments: risk assessment and management.

    PubMed

    Greenberg, Marc S; Chapman, Peter M; Allan, Ian J; Anderson, Kim A; Apitz, Sabine E; Beegan, Chris; Bridges, Todd S; Brown, Steve S; Cargill, John G; McCulloch, Megan C; Menzie, Charles A; Shine, James P; Parkerton, Thomas F

    2014-04-01

    This paper details how activity-based passive sampling methods (PSMs), which provide information on bioavailability in terms of freely dissolved contaminant concentrations (Cfree ), can be used to better inform risk management decision making at multiple points in the process of assessing and managing contaminated sediment sites. PSMs can increase certainty in site investigation and management, because Cfree is a better predictor of bioavailability than total bulk sediment concentration (Ctotal ) for 4 key endpoints included in conceptual site models (benthic organism toxicity, bioaccumulation, sediment flux, and water column exposures). The use of passive sampling devices (PSDs) presents challenges with respect to representative sampling for estimating average concentrations and other metrics relevant for exposure and risk assessment. These challenges can be addressed by designing studies that account for sources of variation associated with PSMs and considering appropriate spatial scales to meet study objectives. Possible applications of PSMs include: quantifying spatial and temporal trends in bioavailable contaminants, identifying and evaluating contaminant source contributions, calibrating site-specific models, and, improving weight-of-evidence based decision frameworks. PSM data can be used to assist in delineating sediment management zones based on likelihood of exposure effects, monitor remedy effectiveness, and, evaluate risk reduction after sediment treatment, disposal, or beneficial reuse after management actions. Examples are provided illustrating why PSMs and freely dissolved contaminant concentrations (Cfree ) should be incorporated into contaminated sediment investigations and study designs to better focus on and understand contaminant bioavailability, more accurately estimate exposure to sediment-associated contaminants, and better inform risk management decisions. Research and communication needs for encouraging broader use are discussed. PMID

  7. Passive sampling methods for contaminated sediments: Risk assessment and management

    PubMed Central

    Greenberg, Marc S; Chapman, Peter M; Allan, Ian J; Anderson, Kim A; Apitz, Sabine E; Beegan, Chris; Bridges, Todd S; Brown, Steve S; Cargill, John G; McCulloch, Megan C; Menzie, Charles A; Shine, James P; Parkerton, Thomas F

    2014-01-01

    This paper details how activity-based passive sampling methods (PSMs), which provide information on bioavailability in terms of freely dissolved contaminant concentrations (Cfree), can be used to better inform risk management decision making at multiple points in the process of assessing and managing contaminated sediment sites. PSMs can increase certainty in site investigation and management, because Cfree is a better predictor of bioavailability than total bulk sediment concentration (Ctotal) for 4 key endpoints included in conceptual site models (benthic organism toxicity, bioaccumulation, sediment flux, and water column exposures). The use of passive sampling devices (PSDs) presents challenges with respect to representative sampling for estimating average concentrations and other metrics relevant for exposure and risk assessment. These challenges can be addressed by designing studies that account for sources of variation associated with PSMs and considering appropriate spatial scales to meet study objectives. Possible applications of PSMs include: quantifying spatial and temporal trends in bioavailable contaminants, identifying and evaluating contaminant source contributions, calibrating site-specific models, and, improving weight-of-evidence based decision frameworks. PSM data can be used to assist in delineating sediment management zones based on likelihood of exposure effects, monitor remedy effectiveness, and, evaluate risk reduction after sediment treatment, disposal, or beneficial reuse after management actions. Examples are provided illustrating why PSMs and freely dissolved contaminant concentrations (Cfree) should be incorporated into contaminated sediment investigations and study designs to better focus on and understand contaminant bioavailability, more accurately estimate exposure to sediment-associated contaminants, and better inform risk management decisions. Research and communication needs for encouraging broader use are discussed. Integr

  8. Passive sampling methods for contaminated sediments: risk assessment and management.

    PubMed

    Greenberg, Marc S; Chapman, Peter M; Allan, Ian J; Anderson, Kim A; Apitz, Sabine E; Beegan, Chris; Bridges, Todd S; Brown, Steve S; Cargill, John G; McCulloch, Megan C; Menzie, Charles A; Shine, James P; Parkerton, Thomas F

    2014-04-01

    This paper details how activity-based passive sampling methods (PSMs), which provide information on bioavailability in terms of freely dissolved contaminant concentrations (Cfree ), can be used to better inform risk management decision making at multiple points in the process of assessing and managing contaminated sediment sites. PSMs can increase certainty in site investigation and management, because Cfree is a better predictor of bioavailability than total bulk sediment concentration (Ctotal ) for 4 key endpoints included in conceptual site models (benthic organism toxicity, bioaccumulation, sediment flux, and water column exposures). The use of passive sampling devices (PSDs) presents challenges with respect to representative sampling for estimating average concentrations and other metrics relevant for exposure and risk assessment. These challenges can be addressed by designing studies that account for sources of variation associated with PSMs and considering appropriate spatial scales to meet study objectives. Possible applications of PSMs include: quantifying spatial and temporal trends in bioavailable contaminants, identifying and evaluating contaminant source contributions, calibrating site-specific models, and, improving weight-of-evidence based decision frameworks. PSM data can be used to assist in delineating sediment management zones based on likelihood of exposure effects, monitor remedy effectiveness, and, evaluate risk reduction after sediment treatment, disposal, or beneficial reuse after management actions. Examples are provided illustrating why PSMs and freely dissolved contaminant concentrations (Cfree ) should be incorporated into contaminated sediment investigations and study designs to better focus on and understand contaminant bioavailability, more accurately estimate exposure to sediment-associated contaminants, and better inform risk management decisions. Research and communication needs for encouraging broader use are discussed.

  9. A cryopreservation method for Pasteurella multocida from wetland samples

    USGS Publications Warehouse

    Moore, Melody K.; Shadduck, D.J.; Goldberg, D.R.; Samuel, M.D.

    1998-01-01

    A cryopreservation method and improved isolation techniques for detection of Pasteurella multocida from wetland samples were developed. Wetland water samples were collected in the field, diluted in dimethyl sulfoxide (DMSO, final concentration 10%), and frozen at -180 C in a liquid nitrogen vapor shipper. Frozen samples were transported to the laboratory where they were subsequently thawed and processed in Pasteurella multocida selective broth (PMSB) to isolate P. multocida. This method allowed for consistent isolation of 2 to 18 organisms/ml from water seeded with known concentrations of P. multocida. The method compared favorably with the standard mouse inoculation method and allowed for preservation of the samples until they could be processed in the laboratory.

  10. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    PubMed

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well. PMID:26107223

  11. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    PubMed

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well.

  12. Neutron activation analysis for antimetabolites. [in food samples

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

  13. Methods of human body odor sampling: the effect of freezing.

    PubMed

    Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan

    2009-02-01

    Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.

  14. Soil separator and sampler and method of sampling

    DOEpatents

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  15. Method and apparatus for imaging a sample on a device

    DOEpatents

    Trulson, Mark; Stern, David; Fiekowsky, Peter; Rava, Richard; Walton, Ian; Fodor, Stephen P. A.

    1996-01-01

    The present invention provides methods and systems for detecting a labeled marker on a sample located on a support. The imaging system comprises a body for immobilizing the support, an excitation radiation source and excitation optics to generate and direct the excitation radiation at the sample. In response, labeled material on the sample emits radiation which has a wavelength that is different from the excitation wavelength, which radiation is collected by collection optics and imaged onto a detector which generates an image of the sample.

  16. System and method for measuring fluorescence of a sample

    SciTech Connect

    Riot, Vincent J

    2015-03-24

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  17. Convenient mounting method for electrical measurements of thin samples

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1986-01-01

    A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

  18. A quantitative evaluation of two methods for preserving hair samples

    USGS Publications Warehouse

    Roon, David A.; Waits, L.P.; Kendall, K.C.

    2003-01-01

    Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.

  19. Comparison of surface sampling methods for virus recovery from fomites.

    PubMed

    Julian, Timothy R; Tamayo, Francisco J; Leckie, James O; Boehm, Alexandria B

    2011-10-01

    The role of fomites in infectious disease transmission relative to other exposure routes is difficult to discern due, in part, to the lack of information on the level and distribution of virus contamination on surfaces. Comparisons of studies intending to fill this gap are difficult because multiple different sampling methods are employed and authors rarely report their method's lower limit of detection. In the present study, we compare a subset of sampling methods identified from a literature review to demonstrate that sampling method significantly influences study outcomes. We then compare a subset of methods identified from the review to determine the most efficient methods for recovering virus from surfaces in a laboratory trial using MS2 bacteriophage as a model virus. Recoveries of infective MS2 and MS2 RNA are determined using both a plaque assay and quantitative reverse transcription-PCR, respectively. We conclude that the method that most effectively recovers virus from nonporous fomites uses polyester-tipped swabs prewetted in either one-quarter-strength Ringer's solution or saline solution. This method recovers a median fraction for infective MS2 of 0.40 and for MS2 RNA of 0.07. Use of the proposed method for virus recovery in future fomite sampling studies would provide opportunities to compare findings across multiple studies.

  20. Active sampling technique to enhance chemical signature of buried explosives

    NASA Astrophysics Data System (ADS)

    Lovell, John S.; French, Patrick D.

    2004-09-01

    Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.

  1. Evaluating Composite Sampling Methods of Bacillus Spores at Low Concentrations

    PubMed Central

    Hess, Becky M.; Amidan, Brett G.; Anderson, Kevin K.; Hutchison, Janine R.

    2016-01-01

    Restoring all facility operations after the 2001 Amerithrax attacks took years to complete, highlighting the need to reduce remediation time. Some of the most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite (SM-SPC): a single cellulose sponge samples multiple coupons with a single pass across each coupon; 2) single medium multi-pass composite: a single cellulose sponge samples multiple coupons with multiple passes across each coupon (SM-MPC); and 3) multi-medium post-sample composite (MM-MPC): a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155 CFU/cm2). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted dry wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p< 0.0001) and coupon material (p = 0.0006). Recovery efficiency (RE) was higher overall using the MM-MPC method compared to the SM-SPC and SM-MPC methods. RE with the MM-MPC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, dry wall, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when

  2. Neutron activation analysis of an Egyptian monazite ore sample

    NASA Astrophysics Data System (ADS)

    Eissa, E. A.; Rofail, N. B.; Ashmawy, L. S.; Hassan, A. M.

    1999-01-01

    The absolute sensitivity of a gamma-ray line following thermal or epithermal neutron activation is expressed as a product of four terms, namely, the intrinsic, irradiation, decay and measurement factors. The total absolute sensitivity is the sum of the absolute sensitivities due to thermal and epithermal activation. A. FORTRAN computer program was prepared on the TANDY 3000 NL PCA to calculate the total absolute sensitivity of the intensive gamma-ray lines from the thermal and epithermal neutron activation of all the naturally occurring nuclides. Another program was prepared for the determination of the total absolute sensitivity for gammarays emitted by radioactive daughters such as233Pa from233Th and239Np from239U. Long time irradiation periods (about 48 hours) for specimens of the monazite ore sample were carried out at the (ET-RR-1) reactor core periphery. The monazite ore sample was separated from the associating minerals in the sand of Abou-Khashaba of Rashied (Rosetta) area on the Mediterranean (North of Egypt). The separated monazite ore sample was provided by the Nuclear Material Authority of Egypt. The cadmium difference method was applied to thin gold foils for absolute thermal and epithermal neutron flux determination. The gamma-ray spectra were measured using a spectrometer with a HPGe coaxial detector. The evaluated absolute sensitivity tables were helpful in identifying the radioisotopes contributing to the gamma- ray spectra and in evaluating the elemental concentration of the monazite constitutents. Most of the rare earth elements were observed and their concentrations are reported. La, Ce, Nd, Sd and Th were found as major elements, U, Tb, Hf and Eu as minor elements.

  3. The Precision Efficacy Analysis for Regression Sample Size Method.

    ERIC Educational Resources Information Center

    Brooks, Gordon P.; Barcikowski, Robert S.

    The general purpose of this study was to examine the efficiency of the Precision Efficacy Analysis for Regression (PEAR) method for choosing appropriate sample sizes in regression studies used for precision. The PEAR method, which is based on the algebraic manipulation of an accepted cross-validity formula, essentially uses an effect size to…

  4. Standard methods for sampling North American freshwater fishes

    USGS Publications Warehouse

    Bonar, Scott A.; Hubert, Wayne A.; Willis, David W.

    2009-01-01

    This important reference book provides standard sampling methods recommended by the American Fisheries Society for assessing and monitoring freshwater fish populations in North America. Methods apply to ponds, reservoirs, natural lakes, and streams and rivers containing cold and warmwater fishes. Range-wide and eco-regional averages for indices of abundance, population structure, and condition for individual species are supplied to facilitate comparisons of standard data among populations. Provides information on converting nonstandard to standard data, statistical and database procedures for analyzing and storing standard data, and methods to prevent transfer of invasive species while sampling.

  5. Beryllium Wipe Sampling (differing methods - differing exposure potentials)

    SciTech Connect

    Kerr, Kent

    2005-03-09

    This research compared three wipe sampling techniques currently used to test for beryllium contamination on room and equipment surfaces in Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling without a wetting agent, with water-moistened wipe materials, and by methanol-moistened wipes. Analysis indicated that methanol-moistened wipe sampling removed about twice as much beryllium/oil-film surface contamination as water-moistened wipes, which removed about twice as much residue as dry wipes. Criteria at 10 CFR 850.30 and .31 were established on unspecified wipe sampling method(s). The results of this study reveal a need to identify criteria-setting method and equivalency factors. As facilities change wipe sampling methods among the three compared in this study, these results may be useful for approximate correlations. Accurate decontamination decision-making depends on the selection of appropriate wetting agents for the types of residues and surfaces. Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced removal efficiency such as methanol when surface contamination includes oil mist residue.

  6. SNS Sample Activation Calculator Flux Recommendations and Validation

    SciTech Connect

    McClanahan, Tucker C.; Gallmeier, Franz X.; Iverson, Erik B.; Lu, Wei

    2015-02-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

  7. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    SciTech Connect

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured [Waite et al., 2008]. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method [Stern et al., 1996], contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method [Handa and Stupin, 1992], water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand [Waite et al., 2004]. In the dissolved gas method [Tohidi et al., 2002], water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming [Minagawa et al., 2005; Spangenberg and Kulenkampff, 2005]. In another version of this technique, a specified quantity of gas

  8. Fluidics platform and method for sample preparation and analysis

    SciTech Connect

    Benner, W. Henry; Dzenitis, John M.; Bennet, William J.; Baker, Brian R.

    2014-08-19

    Herein provided are fluidics platform and method for sample preparation and analysis. The fluidics platform is capable of analyzing DNA from blood samples using amplification assays such as polymerase-chain-reaction assays and loop-mediated-isothermal-amplification assays. The fluidics platform can also be used for other types of assays and analyzes. In some embodiments, a sample in a sealed tube can be inserted directly. The following isolation, detection, and analyzes can be performed without a user's intervention. The disclosed platform may also comprises a sample preparation system with a magnetic actuator, a heater, and an air-drying mechanism, and fluid manipulation processes for extraction, washing, elution, assay assembly, assay detection, and cleaning after reactions and between samples.

  9. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.

    1996-03-26

    Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.

  10. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.

    1996-01-01

    Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.

  11. Characterizing lentic freshwater fish assemblages using multiple sampling methods

    USGS Publications Warehouse

    Fischer, Jesse R.; Quist, Michael

    2014-01-01

    Characterizing fish assemblages in lentic ecosystems is difficult, and multiple sampling methods are almost always necessary to gain reliable estimates of indices such as species richness. However, most research focused on lentic fish sampling methodology has targeted recreationally important species, and little to no information is available regarding the influence of multiple methods and timing (i.e., temporal variation) on characterizing entire fish assemblages. Therefore, six lakes and impoundments (48–1,557 ha surface area) were sampled seasonally with seven gear types to evaluate the combined influence of sampling methods and timing on the number of species and individuals sampled. Probabilities of detection for species indicated strong selectivities and seasonal trends that provide guidance on optimal seasons to use gears when targeting multiple species. The evaluation of species richness and number of individuals sampled using multiple gear combinations demonstrated that appreciable benefits over relatively few gears (e.g., to four) used in optimal seasons were not present. Specifically, over 90 % of the species encountered with all gear types and season combinations (N = 19) from six lakes and reservoirs were sampled with nighttime boat electrofishing in the fall and benthic trawling, modified-fyke, and mini-fyke netting during the summer. Our results indicated that the characterization of lentic fish assemblages was highly influenced by the selection of sampling gears and seasons, but did not appear to be influenced by waterbody type (i.e., natural lake, impoundment). The standardization of data collected with multiple methods and seasons to account for bias is imperative to monitoring of lentic ecosystems and will provide researchers with increased reliability in their interpretations and decisions made using information on lentic fish assemblages.

  12. Comparison of pigment content of paint samples using spectrometric methods.

    PubMed

    Trzcińska, Beata; Kowalski, Rafał; Zięba-Palus, Janina

    2014-09-15

    The aim of the paper was to evaluate the influence of pigment concentration and its distribution in polymer binder on the possibility of colour identification and paint sample comparison. Two sets of paint samples: one containing red and another one green pigment were prepared. Each set consisted of 13 samples differing gradually in the concentration of pigment. To obtain the sets of various colour shades white paint was mixed with the appropriate pigment in the form of a concentrated suspension. After solvents evaporation the samples were examined using spectrometric methods. The resin and main filler were identified by IR method. Colour and white pigments were identified on the base of Raman spectra. Colour of samples were compared based on Vis spectrometry according to colour theory. It was found that samples are homogenous (parameter measuring colour similarity ΔE<3). The values of ΔE between the neighbouring samples in the set revealed decreasing linear function and between the first and following one--a logarithmic function.

  13. Off-axis angular spectrum method with variable sampling interval

    NASA Astrophysics Data System (ADS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Pi, Jae-Eun; Choi, Ji-Hun; Kim, Gi Heon; Lee, Myung-Lae; Ryu, Hojun; Hwang, Chi-Sun

    2015-08-01

    We proposed a novel off-axis angular spectrum method (ASM) for simulating free space wave propagation with a large shifted destination plane. The off-axis numerical simulation took wave propagation between a parallel source and a destination plane, but a destination plane was shifted from a source plane. The shifted angular spectrum method was proposed for diffraction simulation with a shifted destination plane and satisfied the Nyquist condition for sampling by limiting a bandwidth of a propagation field to avoid an aliasing error due to under sampling. However, the effective sampling number of the shifted ASM decreased when the shifted distance of the destination plane was large which caused a numerical error in the diffraction simulation. To compensate for the decrease of an effective sampling number for the large shifted destination plane, we used a variable sampling interval in a Fourier space to maintain the same effective sampling number independent of the shifted distance of the destination plane. As a result, our proposed off-axis ASM with a variable sampling interval can produce simulation results with high accuracy for nearly every shifted distance of a destination plane when an off-axis angle is less than 75°. We compared the performances of the off-axis ASM using the Chirp Z transform and non-uniform FFT for implementing a variable spatial frequency in a Fourier space.

  14. Comparison of pigment content of paint samples using spectrometric methods

    NASA Astrophysics Data System (ADS)

    Trzcińska, Beata; Kowalski, Rafał; Zięba-Palus, Janina

    2014-09-01

    The aim of the paper was to evaluate the influence of pigment concentration and its distribution in polymer binder on the possibility of colour identification and paint sample comparison. Two sets of paint samples: one containing red and another one green pigment were prepared. Each set consisted of 13 samples differing gradually in the concentration of pigment. To obtain the sets of various colour shades white paint was mixed with the appropriate pigment in the form of a concentrated suspension. After solvents evaporation the samples were examined using spectrometric methods. The resin and main filler were identified by IR method. Colour and white pigments were identified on the base of Raman spectra. Colour of samples were compared based on Vis spectrometry according to colour theory. It was found that samples are homogenous (parameter measuring colour similarity ΔE < 3). The values of ΔE between the neighbouring samples in the set revealed decreasing linear function and between the first and following one - a logarithmic function.

  15. [Progress in sample preparation and analytical methods for trace polar small molecules in complex samples].

    PubMed

    Zhang, Qianchun; Luo, Xialin; Li, Gongke; Xiao, Xiaohua

    2015-09-01

    Small polar molecules such as nucleosides, amines, amino acids are important analytes in biological, food, environmental, and other fields. It is necessary to develop efficient sample preparation and sensitive analytical methods for rapid analysis of these polar small molecules in complex matrices. Some typical materials in sample preparation, including silica, polymer, carbon, boric acid and so on, are introduced in this paper. Meanwhile, the applications and developments of analytical methods of polar small molecules, such as reversed-phase liquid chromatography, hydrophilic interaction chromatography, etc., are also reviewed. PMID:26753274

  16. RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-07-17

    A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

  17. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    SciTech Connect

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides and strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.

  18. On the Exploitation of Sensitivity Derivatives for Improving Sampling Methods

    NASA Technical Reports Server (NTRS)

    Cao, Yanzhao; Hussaini, M. Yousuff; Zang, Thomas A.

    2003-01-01

    Many application codes, such as finite-element structural analyses and computational fluid dynamics codes, are capable of producing many sensitivity derivatives at a small fraction of the cost of the underlying analysis. This paper describes a simple variance reduction method that exploits such inexpensive sensitivity derivatives to increase the accuracy of sampling methods. Three examples, including a finite-element structural analysis of an aircraft wing, are provided that illustrate an order of magnitude improvement in accuracy for both Monte Carlo and stratified sampling schemes.

  19. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  20. Comparison of sampling methods for radiocarbon dating of carbonyls in air samples via accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schindler, Matthias; Kretschmer, Wolfgang; Scharf, Andreas; Tschekalinskij, Alexander

    2016-05-01

    Three new methods to sample and prepare various carbonyl compounds for radiocarbon measurements were developed and tested. Two of these procedures utilized the Strecker synthetic method to form amino acids from carbonyl compounds with either sodium cyanide or trimethylsilyl cyanide. The third procedure used semicarbazide to form crystalline carbazones with the carbonyl compounds. The resulting amino acids and semicarbazones were then separated and purified using thin layer chromatography. The separated compounds were then combusted to CO2 and reduced to graphite to determine 14C content by accelerator mass spectrometry (AMS). All of these methods were also compared with the standard carbonyl compound sampling method wherein a compound is derivatized with 2,4-dinitrophenylhydrazine and then separated by high-performance liquid chromatography (HPLC).

  1. Exposure to airborne allergens: a review of sampling methods.

    PubMed

    Renström, Anne

    2002-10-01

    A number of methods are used to assess exposure to high-molecular weight allergens. In the occupational setting, airborne dust is often collected on filters using pumps, the filters are eluted and allergen content in the eluate analysed using immunoassays. Collecting inhalable dust using person-carried pumps may be considered the gold standard. Other allergen sampling methods are available. Recently, a method that collects nasally inhaled dust on adhesive surfaces within nasal samplers has been developed. Allergen content can be analysed in eluates using sensitive enzyme immunoassays, or allergen-bearing particles can be immunostained using antibodies, and studied under the microscope. Settling airborne dust can be collected in petri dishes, a cheap and simple method that has been utilised in large-scale exposure studies. Collection of reservoir dust from surfaces using vacuum cleaners with a dust collector is commonly used to measure pet or mite allergens in homes. The sampling methods differ in properties and relevance to personal allergen exposure. Since methods for all steps from sampling to analysis differ between laboratories, determining occupational exposure limits for protein allergens is today unfeasible. A general standardisation of methods is needed.

  2. Sampling methods for monitoring changes in gonococcal populations.

    PubMed Central

    Bindayna, K. M.; Ison, C. A.

    1989-01-01

    A total of 160 consecutive isolates of Neisseria gonorrhoeae was collected over a 3-month period. They were tested for their susceptibility to penicillin, erythromycin and spectinomycin and the auxotype and the serotype determined. We have evaluated two sampling methods, the collection of every fifth isolate and the first 20 isolates (10 male and 10 female) each month, to determine whether either is representative of the total population. There was no significant difference between either method of sampling and the total for detecting the predominant auxotypes and serovars or the distributions in antibiotic susceptibility. It is possible to monitor major changes in a gonococcal population, particularly susceptibility to antibiotics, using a sample of the total population. PMID:2528473

  3. A New GP Recombination Method Using Random Tree Sampling

    NASA Astrophysics Data System (ADS)

    Tanji, Makoto; Iba, Hitoshi

    We propose a new program evolution method named PORTS (Program Optimization by Random Tree Sampling) which is motivated by the idea of preservation and control of tree fragments in GP (Genetic Programming). We assume that to recombine genetic materials efficiently, tree fragments of any size should be preserved into the next generation. PORTS samples tree fragments and concatenates them by traversing and transitioning between promising trees instead of using subtree crossover and mutation. Because the size of a fragment preserved during a generation update follows a geometric distribution, merits of the method are that it is relatively easy to predict the behavior of tree fragments over time and to control sampling size, by changing a single parameter. From experimental results on RoyalTree, Symbolic Regression and 6-Multiplexer problem, we observed that the performance of PORTS is competitive with Simple GP. Furthermore, the average node size of optimal solutions obtained by PORTS was simple than Simple GP's result.

  4. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  5. Development of an automated data processing method for sample to sample comparison of seized methamphetamines.

    PubMed

    Choe, Sanggil; Lee, Jaesin; Choi, Hyeyoung; Park, Yujin; Lee, Heesang; Pyo, Jaesung; Jo, Jiyeong; Park, Yonghoon; Choi, Hwakyung; Kim, Suncheun

    2012-11-30

    The information about the sources of supply, trafficking routes, distribution patterns and conspiracy links can be obtained from methamphetamine profiling. The precursor and synthetic method for the clandestine manufacture can be estimated from the analysis of minor impurities contained in methamphetamine. Also, the similarity between samples can be evaluated using the peaks that appear in chromatograms. In South Korea, methamphetamine was the most popular drug but the total seized amount of methamphetamine whole through the country was very small. Therefore, it would be more important to find the links between samples than the other uses of methamphetamine profiling. Many Asian countries including Japan and South Korea have been using the method developed by National Research Institute of Police Science of Japan. The method used gas chromatography-flame ionization detector (GC-FID), DB-5 column and four internal standards. It was developed to increase the amount of impurities and minimize the amount of methamphetamine. After GC-FID analysis, the raw data have to be processed. The data processing steps are very complex and require a lot of time and effort. In this study, Microsoft Visual Basic Application (VBA) modules were developed to handle these data processing steps. This module collected the results from the data into an Excel file and then corrected the retention time shift and response deviation generated from the sample preparation and instruments analysis. The developed modules were tested for their performance using 10 samples from 5 different cases. The processed results were analyzed with Pearson correlation coefficient for similarity assessment and the correlation coefficient of the two samples from the same case was more than 0.99. When the modules were applied to 131 seized methamphetamine samples, four samples from two different cases were found to have the common origin and the chromatograms of the four samples were appeared visually identical

  6. A General Linear Method for Equating with Small Samples

    ERIC Educational Resources Information Center

    Albano, Anthony D.

    2015-01-01

    Research on equating with small samples has shown that methods with stronger assumptions and fewer statistical estimates can lead to decreased error in the estimated equating function. This article introduces a new approach to linear observed-score equating, one which provides flexible control over how form difficulty is assumed versus estimated…

  7. Periodicity detection method for small-sample time series datasets.

    PubMed

    Tominaga, Daisuke

    2010-01-01

    Time series of gene expression often exhibit periodic behavior under the influence of multiple signal pathways, and are represented by a model that incorporates multiple harmonics and noise. Most of these data, which are observed using DNA microarrays, consist of few sampling points in time, but most periodicity detection methods require a relatively large number of sampling points. We have previously developed a detection algorithm based on the discrete Fourier transform and Akaike's information criterion. Here we demonstrate the performance of the algorithm for small-sample time series data through a comparison with conventional and newly proposed periodicity detection methods based on a statistical analysis of the power of harmonics.We show that this method has higher sensitivity for data consisting of multiple harmonics, and is more robust against noise than other methods. Although "combinatorial explosion" occurs for large datasets, the computational time is not a problem for small-sample datasets. The MATLAB/GNU Octave script of the algorithm is available on the author's web site: http://www.cbrc.jp/%7Etominaga/piccolo/. PMID:21151841

  8. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Sipila, Stephanie A.; Scoville, Zebulon C.; Bowie, Jonathan T.; Buffington, Jesse A.

    2014-01-01

    One of the challenging primary objectives associated with NASA's Asteroid Redirect Crewed Mission (ARCM) is to demonstrate deep space Extravehicular Activity (EVA) and tools and to obtain asteroid samples to return to Earth for further study. Prior Shuttle and International Space Station (ISS) spacewalks have benefited from engineered EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as behavior of the asteroid capture mechanism will complicate EVA translation, tool restraint, and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the Modified Advanced Crew Escape Suit (MACES) suit. This paper will summarize the overall operational concepts for conducting EVAs for the ARCM mission including translation paths and body restraint methods, potential tools used to extract the samples, design implications for the Asteroid Redirect Vehicle (ARV) for EVA, and the results of early development testing of potential EVA tasks.

  9. Comparison of DNA preservation methods for environmental bacterial community samples

    USGS Publications Warehouse

    Gray, Michael A.; Pratte, Zoe A.; Kellogg, Christina A.

    2013-01-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard™, RNAlater®, DMSO–EDTA–salt (DESS), FTA® cards, and FTA Elute® cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA® cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard™, RNAlater®, and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost.

  10. Comparison of aquatic macroinvertebrate samples collected using different field methods

    USGS Publications Warehouse

    Lenz, Bernard N.; Miller, Michael A.

    1996-01-01

    Government agencies, academic institutions, and volunteer monitoring groups in the State of Wisconsin collect aquatic macroinvertebrate data to assess water quality. Sampling methods differ among agencies, reflecting the differences in the sampling objectives of each agency. Lack of infor- mation about data comparability impedes data shar- ing among agencies, which can result in duplicated sampling efforts or the underutilization of avail- able information. To address these concerns, com- parisons were made of macroinvertebrate samples collected from wadeable streams in Wisconsin by personnel from the U.S. Geological Survey- National Water Quality Assessment Program (USGS-NAWQA), the Wisconsin Department of Natural Resources (WDNR), the U.S. Department of Agriculture-Forest Service (USDA-FS), and volunteers from the Water Action Volunteer-Water Quality Monitoring Program (WAV). This project was part of the Intergovernmental Task Force on Monitoring Water Quality (ITFM) Wisconsin Water Resources Coordination Project. The numbers, types, and environmental tolerances of the organ- isms collected were analyzed to determine if the four different field methods that were used by the different agencies and volunteer groups provide comparable results. Additionally, this study com- pared the results of samples taken from different locations and habitats within the same streams.

  11. Extravehicular Activity Asteroid Exploration and Sample Collection Capability

    NASA Technical Reports Server (NTRS)

    Scoville, Zebulon; Sipila, Stephanie; Bowie, Jonathan

    2014-01-01

    NASA's Asteroid Redirect Crewed Mission (ARCM) is challenged with primary mission objectives of demonstrating deep space Extravehicular Activity (EVA) and tools, and obtaining asteroid samples to return to Earth for further study. Although the Modified Advanced Crew Escape Suit (MACES) is used for the EVAs, it has limited mobility which increases fatigue and decreases the crews' capability to perform EVA tasks. Furthermore, previous Shuttle and International Space Station (ISS) spacewalks have benefited from EVA interfaces which have been designed and manufactured on Earth. Rigid structurally mounted handrails, and tools with customized interfaces and restraints optimize EVA performance. For ARCM, some vehicle interfaces and tools can leverage heritage designs and experience. However, when the crew ventures onto an asteroid capture bag to explore the asteroid and collect rock samples, EVA complexity increases due to the uncertainty of the asteroid properties. The variability of rock size, shape and composition, as well as bunching of the fabric bag will complicate EVA translation, tool restraint and body stabilization. The unknown asteroid hardness and brittleness will complicate tool use. The rock surface will introduce added safety concerns for cut gloves and debris control. Feasible solutions to meet ARCM EVA objectives were identified using experience gained during Apollo, Shuttle, and ISS EVAs, terrestrial mountaineering practices, NASA Extreme Environment Mission Operations (NEEMO) 16 mission, and during Neutral Buoyancy Laboratory testing in the MACES suit. The proposed concept utilizes expandable booms and integrated features of the asteroid capture bag to position and restrain the crew at the asteroid worksite. These methods enable the capability to perform both finesse, and high load tasks necessary to collect samples for scientific characterization of the asteroid. This paper will explore the design trade space and options that were examined for EVA, the

  12. Assessment of dust sampling methods for the study of cultivable-microorganism exposure in stables.

    PubMed

    Normand, Anne-Cécile; Vacheyrou, Mallory; Sudre, Bertrand; Heederik, Dick J J; Piarroux, Renaud

    2009-12-01

    Studies have shown a link between living on a farm, exposure to microbial components (e.g., endotoxins or beta-d-glucans), and a lower risk for allergic diseases and asthma. Due to the lack of validated sampling methods, studies of asthma and atopy have not relied on exposure assessment based on culture techniques. Our objective was therefore to compare several dust sampling methods for the detection of cultivable-microorganism exposure in stables. Sixteen French farms were sampled using four different methods: (i) active air sampling using a pump, (ii) passive dust sampling with a plastic box, (iii) dust sampling with an electrostatic dust fall collector (wipe), and (iv) dust sampling using a spatula to collect dust already settled on a windowsill. The results showed that collection of settled dust samples with either plastic boxes or wipes was reproducible (pairwise correlations, 0.72 and 0.73, respectively) and resulted in highly correlated results (pairwise correlation between the two methods, 0.82). We also found that settled dust samples collected with a plastic box correctly reflected the composition of the samples collected in the air of the stable when there was no farmer activity. A loss of microbial diversity was observed when dust was kept for 3 months at room temperature. We therefore conclude that measurement of viable microorganisms within a reasonable time frame gives an accurate representation of the microbial composition of stable air.

  13. A flexible importance sampling method for integrating subgrid processes

    NASA Astrophysics Data System (ADS)

    Raut, E. K.; Larson, V. E.

    2016-01-01

    Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that contains both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.

  14. New Methods of Sample Preparation for Atom Probe Specimens

    NASA Technical Reports Server (NTRS)

    Kuhlman, Kimberly, R.; Kowalczyk, Robert S.; Ward, Jennifer R.; Wishard, James L.; Martens, Richard L.; Kelly, Thomas F.

    2003-01-01

    Magnetite is a common conductive mineral found on Earth and Mars. Disk-shaped precipitates approximately 40 nm in diameter have been shown to have manganese and aluminum concentrations. Atom-probe field-ion microscopy (APFIM) is the only technique that can potentially quantify the composition of these precipitates. APFIM will be used to characterize geological and planetary materials, analyze samples of interest for geomicrobiology; and, for the metrology of nanoscale instrumentation. Prior to APFIM sample preparation was conducted by electropolishing, the method of sharp shards (MSS), or Bosch process (deep reactive ion etching) with focused ion beam (FIB) milling as a final step. However, new methods are required for difficult samples. Many materials are not easily fabricated using electropolishing, MSS, or the Bosch process, FIB milling is slow and expensive, and wet chemistry and the reactive ion etching are typically limited to Si and other semiconductors. APFIM sample preparation using the dicing saw is commonly used to section semiconductor wafers into individual devices following manufacture. The dicing saw is a time-effective method for preparing high aspect ratio posts of poorly conducting materials. Femtosecond laser micromachining is also suitable for preparation of posts. FIB time required is reduced by about a factor of 10 and multi-tip specimens can easily be fabricated using the dicing saw.

  15. A flexible importance sampling method for integrating subgrid processes

    DOE PAGES

    Raut, E. K.; Larson, V. E.

    2016-01-29

    Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that containsmore » both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.« less

  16. A method for sampling microbial aerosols using high altitude balloons.

    PubMed

    Bryan, N C; Stewart, M; Granger, D; Guzik, T G; Christner, B C

    2014-12-01

    Owing to the challenges posed to microbial aerosol sampling at high altitudes, very little is known about the abundance, diversity, and extent of microbial taxa in the Earth-atmosphere system. To directly address this knowledge gap, we designed, constructed, and tested a system that passively samples aerosols during ascent through the atmosphere while tethered to a helium-filled latex sounding balloon. The sampling payload is ~ 2.7 kg and comprised of an electronics box and three sampling chambers (one serving as a procedural control). Each chamber is sealed with retractable doors that can be commanded to open and close at designated altitudes. The payload is deployed together with radio beacons that transmit GPS coordinates (latitude, longitude and altitude) in real time for tracking and recovery. A cut mechanism separates the payload string from the balloon at any desired altitude, returning all equipment safely to the ground on a parachute. When the chambers are opened, aerosol sampling is performed using the Rotorod® collection method (40 rods per chamber), with each rod passing through 0.035 m3 per km of altitude sampled. Based on quality control measurements, the collection of ~ 100 cells rod(-1) provided a 3-sigma confidence level of detection. The payload system described can be mated with any type of balloon platform and provides a tool for characterizing the vertical distribution of microorganisms in the troposphere and stratosphere. PMID:25455021

  17. Genomic DNA microextraction: a method to screen numerous samples.

    PubMed

    Ramírez-Solis, R; Rivera-Pérez, J; Wallace, J D; Wims, M; Zheng, H; Bradley, A

    1992-03-01

    Many experimental designs require the analysis of genomic DNA from a large number of samples. Although the polymerase chain reaction (PCR) can be used, the Southern blot is preferred for many assays because of its inherent reliability. The rapid acceptance of PCR, despite a significant rate of false positive/negative results, is partly due to the disadvantages of the sample preparation process for Southern blot analysis. We have devised a rapid protocol to extract high-molecular-weight genomic DNA from a large number of samples. It involves the use of a single 96-well tissue culture dish to carry out all the steps of the sample preparation. This, coupled with the use of a multichannel pipette, facilitates the simultaneous analysis of multiple samples. The procedure may be automated since no centrifugation, mixing, or transferring of the samples is necessary. The method has been used to screen embryonic stem cell clones for the presence of targeted mutations at the Hox-2.6 locus and to obtain data from human blood.

  18. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    SciTech Connect

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits.

  19. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY SOIL SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.; Noyes, G.

    2009-11-09

    A new rapid method for the determination of actinides in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for samples up to 2 grams in emergency response situations. The actinides in soil method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride soil matrix removal step, and a streamlined column separation process with stacked TEVA, TRU and DGA Resin cartridges. Lanthanum was separated rapidly and effectively from Am and Cm on DGA Resin. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha sources are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency soil samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinides in soil results were reported within 4-5 hours with excellent quality.

  20. Comparison of clinical samples and methods in chronic cutaneous leishmaniasis.

    PubMed

    Eroglu, Fadime; Uzun, Soner; Koltas, Ismail Soner

    2014-11-01

    This study aimed at finding out the most effective clinical samples and methods in chronic cutaneous leishmaniasis (CCL). Smear, aspiration fluid, and filter paper samples were taken from 104 skin lesions of suspected cases with CCL, and they were compared using microscopic examination, culture, and molecular methods. We characterized four different forms of CCL and identified the causative agents in CCL forms using high-resolution melting curve real-time polymerase chain reaction assay. We observed that smear was detected to be the most sensitive (63.5%) among clinical samples, and real-time polymerase chain reaction method was the most sensitive (96.8%) among the methods used in diagnosis of CCL. We identified 68.8% Leishmania tropica and 31.2% L. infantum in papular lesions, 69.2% L. infantum and 30.8% L. tropica in nodular lesions, 57.9% L. tropica and 42.1% L. major in ulcerating plaque lesions, and 55.5% L. tropica and 44.5% L. major in noduloulcerative lesions in CCL patients.

  1. Spanish Multicenter Normative Studies (NEURONORMA Project): methods and sample characteristics.

    PubMed

    Peña-Casanova, Jordi; Blesa, Rafael; Aguilar, Miquel; Gramunt-Fombuena, Nina; Gómez-Ansón, Beatriz; Oliva, Rafael; Molinuevo, José Luis; Robles, Alfredo; Barquero, María Sagrario; Antúnez, Carmen; Martínez-Parra, Carlos; Frank-García, Anna; Fernández, Manuel; Alfonso, Verónica; Sol, Josep M

    2009-06-01

    This paper describes the methods and sample characteristics of a series of Spanish normative studies (The NEURONORMA project). The primary objective of our research was to collect normative and psychometric information on a sample of people aged over 49 years. The normative information was based on a series of selected, but commonly used, neuropsychological tests covering attention, language, visuo-perceptual abilities, constructional tasks, memory, and executive functions. A sample of 356 community dwelling individuals was studied. Demographics, socio-cultural, and medical data were collected. Cognitive normality was validated via informants and a cognitive screening test. Norms were calculated for midpoint age groups. Effects of age, education, and sex were determined. The use of these norms should improve neuropsychological diagnostic accuracy in older Spanish subjects. These data may also be of considerable use for comparisons with other normative studies. Limitations of these normative data are also commented on.

  2. Evaluation of sample preservation methods for poultry manure.

    PubMed

    Pan, J; Fadel, J G; Zhang, R; El-Mashad, H M; Ying, Y; Rumsey, T

    2009-08-01

    When poultry manure is collected but cannot be analyzed immediately, a method for storing the manure is needed to ensure accurate subsequent analyses. This study has 3 objectives: (1) to investigate effects of 4 poultry manure sample preservation methods (refrigeration, freezing, acidification, and freeze-drying) on the compositional characteristics of poultry manure; (2) to determine compositional differences in fresh manure with manure samples at 1, 2, and 3 d of accumulation under bird cages; and (3) to assess the influence of 14-d freezing storage on the composition of manure when later exposed to 25 degrees C for 7 d as compared with fresh manure. All manure samples were collected from a layer house. Analyses performed on the manure samples included total Kjeldahl nitrogen, uric acid nitrogen, ammonia nitrogen, and urea nitrogen. In experiment 1, the storage methods most similar to fresh manure, in order of preference, were freezing, freeze-drying, acidification, and refrigeration. Thoroughly mixing manure samples and compressing them to 2 to 3 mm is important for the freezing and freeze-dried samples. In general, refrigeration was found unacceptable for nitrogen analyses. A significant effect (P < 0.0001) of time for refrigeration was found on uric acid nitrogen and ammonia nitrogen. In experiment 2, the total Kjeldahl nitrogen and uric acid nitrogen were significantly lower (P < 0.05) for 1, 2, and 3 d of accumulation compared with fresh manure. Manure after 1, 2, and 3 d of accumulation had similar nitrogen compositions. The results from experiment 3 show that nitrogen components from fresh manure samples and thawed samples from 14 d of freezing are similar at 7 d but high variability of nitrogen compositions during intermediate times from 0 to 7 d prevents the recommendation of freezing manure for use in subsequent experiments and warrants future experimentation. In conclusion, fresh poultry manure can be frozen for accurate subsequent nitrogen

  3. Evaluation of sample preservation methods for poultry manure.

    PubMed

    Pan, J; Fadel, J G; Zhang, R; El-Mashad, H M; Ying, Y; Rumsey, T

    2009-08-01

    When poultry manure is collected but cannot be analyzed immediately, a method for storing the manure is needed to ensure accurate subsequent analyses. This study has 3 objectives: (1) to investigate effects of 4 poultry manure sample preservation methods (refrigeration, freezing, acidification, and freeze-drying) on the compositional characteristics of poultry manure; (2) to determine compositional differences in fresh manure with manure samples at 1, 2, and 3 d of accumulation under bird cages; and (3) to assess the influence of 14-d freezing storage on the composition of manure when later exposed to 25 degrees C for 7 d as compared with fresh manure. All manure samples were collected from a layer house. Analyses performed on the manure samples included total Kjeldahl nitrogen, uric acid nitrogen, ammonia nitrogen, and urea nitrogen. In experiment 1, the storage methods most similar to fresh manure, in order of preference, were freezing, freeze-drying, acidification, and refrigeration. Thoroughly mixing manure samples and compressing them to 2 to 3 mm is important for the freezing and freeze-dried samples. In general, refrigeration was found unacceptable for nitrogen analyses. A significant effect (P < 0.0001) of time for refrigeration was found on uric acid nitrogen and ammonia nitrogen. In experiment 2, the total Kjeldahl nitrogen and uric acid nitrogen were significantly lower (P < 0.05) for 1, 2, and 3 d of accumulation compared with fresh manure. Manure after 1, 2, and 3 d of accumulation had similar nitrogen compositions. The results from experiment 3 show that nitrogen components from fresh manure samples and thawed samples from 14 d of freezing are similar at 7 d but high variability of nitrogen compositions during intermediate times from 0 to 7 d prevents the recommendation of freezing manure for use in subsequent experiments and warrants future experimentation. In conclusion, fresh poultry manure can be frozen for accurate subsequent nitrogen

  4. A Mixed Methods Investigation of Mixed Methods Sampling Designs in Social and Health Science Research

    ERIC Educational Resources Information Center

    Collins, Kathleen M. T.; Onwuegbuzie, Anthony J.; Jiao, Qun G.

    2007-01-01

    A sequential design utilizing identical samples was used to classify mixed methods studies via a two-dimensional model, wherein sampling designs were grouped according to the time orientation of each study's components and the relationship of the qualitative and quantitative samples. A quantitative analysis of 121 studies representing nine fields…

  5. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs.

  6. A direct method for e-cigarette aerosol sample collection.

    PubMed

    Olmedo, Pablo; Navas-Acien, Ana; Hess, Catherine; Jarmul, Stephanie; Rule, Ana

    2016-08-01

    E-cigarette use is increasing in populations around the world. Recent evidence has shown that the aerosol produced by e-cigarettes can contain a variety of toxicants. Published studies characterizing toxicants in e-cigarette aerosol have relied on filters, impingers or sorbent tubes, which are methods that require diluting or extracting the sample in a solution during collection. We have developed a collection system that directly condenses e-cigarette aerosol samples for chemical and toxicological analyses. The collection system consists of several cut pipette tips connected with short pieces of tubing. The pipette tip-based collection system can be connected to a peristaltic pump, a vacuum pump, or directly to an e-cigarette user for the e-cigarette aerosol to flow through the system. The pipette tip-based system condenses the aerosol produced by the e-cigarette and collects a liquid sample that is ready for analysis without the need of intermediate extraction solutions. We tested a total of 20 e-cigarettes from 5 different brands commercially available in Maryland. The pipette tip-based collection system condensed between 0.23 and 0.53mL of post-vaped e-liquid after 150 puffs. The proposed method is highly adaptable, can be used during field work and in experimental settings, and allows collecting aerosol samples from a wide variety of e-cigarette devices, yielding a condensate of the likely exact substance that is being delivered to the lungs. PMID:27200479

  7. Methods for the analysis of carpet samples for asbestos

    SciTech Connect

    Millette, J.R.; Clark, P.J.; Brackett, K.A.; Wheeles, R.K.

    1993-01-01

    Because of the nature of carpet pile, no samples can be directly prepared from carpet for analysis by transmission electron microscopy (TEM). Two indirect methods are currently used by laboratories when preparing samples for measuring the amount of asbestos present in carpet material. One is an ultrasonic shaking technique which requires that a portion of the carpet be cut and sent to the laboratory. The other is a micro-vacuuming technique which has been used generally in the assessment of asbestos in settled dust in buildings. It is not destructive to the carpet. Both methods utilize TEM to identify, measure and count the asbestos fibers found. Each can provide important but different information when an assessment of the level of contamination of carpeting is being made.

  8. Activation energy for a model ferrous-ferric half reaction from transition path sampling.

    PubMed

    Drechsel-Grau, Christof; Sprik, Michiel

    2012-01-21

    Activation parameters for the model oxidation half reaction of the classical aqueous ferrous ion are compared for different molecular simulation techniques. In particular, activation free energies are obtained from umbrella integration and Marcus theory based thermodynamic integration, which rely on the diabatic gap as the reaction coordinate. The latter method also assumes linear response, and both methods obtain the activation entropy and the activation energy from the temperature dependence of the activation free energy. In contrast, transition path sampling does not require knowledge of the reaction coordinate and directly yields the activation energy [C. Dellago and P. G. Bolhuis, Mol. Simul. 30, 795 (2004)]. Benchmark activation energies from transition path sampling agree within statistical uncertainty with activation energies obtained from standard techniques requiring knowledge of the reaction coordinate. In addition, it is found that the activation energy for this model system is significantly smaller than the activation free energy for the Marcus model, approximately half the value, implying an equally large entropy contribution.

  9. Rock sampling. [method for controlling particle size distribution

    NASA Technical Reports Server (NTRS)

    Blum, P. (Inventor)

    1971-01-01

    A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

  10. Sediment sampling and processing methods in Hungary, and possible improvements

    NASA Astrophysics Data System (ADS)

    Tamas, Eniko Anna; Koch, Daniel; Varga, Gyorgy

    2016-04-01

    The importance of the monitoring of sediment processes is unquestionable: sediment balance of regulated rivers suffered substantial alterations in the past century, affecting navigation, energy production, fish habitats and floodplain ecosystems alike; infiltration times to our drinking water wells have shortened, exposing them to an eventual pollution event and making them vulnerable; and sediment-attached contaminants accumulate in floodplains and reservoirs, threatening our healthy environment. The changes in flood characteristics and rating curves of our rivers are regularly being researched and described, involving state-of-the-art measurement methods, modeling tools and traditional statistics. Sediment processes however, are much less known. Unlike the investigation of flow processes, sediment-related research is scarce, which is partly due to the outdated methodology and poor database background in the specific field. Sediment-related data, information and analyses form an important and integral part of Civil engineering in relation to rivers all over the world. In relation to the second largest river of Europe, the Danube, it is widely known in expert community and for long discussed at different expert forums that the sediment balance of the river Danube has changed drastically over the past century. Sediment monitoring on the river Danube started as early as the end of the 19th century, with scattered measurements carried out. Regular sediment sampling was developed in the first half of the 20th century all along the river, with different station density and monitoring frequencies in different countries. After the first few decades of regular sampling, the concept of (mainly industrial) development changed along the river and data needs changed as well, furthermore the complicated and inexact methods of sampling bed load on the alluvial reach of the river were not developed further. Frequency of suspended sediment sampling is very low along the river

  11. Sediment sampling and processing methods in Hungary, and possible improvements

    NASA Astrophysics Data System (ADS)

    Tamas, Eniko Anna; Koch, Daniel; Varga, Gyorgy

    2016-04-01

    The importance of the monitoring of sediment processes is unquestionable: sediment balance of regulated rivers suffered substantial alterations in the past century, affecting navigation, energy production, fish habitats and floodplain ecosystems alike; infiltration times to our drinking water wells have shortened, exposing them to an eventual pollution event and making them vulnerable; and sediment-attached contaminants accumulate in floodplains and reservoirs, threatening our healthy environment. The changes in flood characteristics and rating curves of our rivers are regularly being researched and described, involving state-of-the-art measurement methods, modeling tools and traditional statistics. Sediment processes however, are much less known. Unlike the investigation of flow processes, sediment-related research is scarce, which is partly due to the outdated methodology and poor database background in the specific field. Sediment-related data, information and analyses form an important and integral part of Civil engineering in relation to rivers all over the world. In relation to the second largest river of Europe, the Danube, it is widely known in expert community and for long discussed at different expert forums that the sediment balance of the river Danube has changed drastically over the past century. Sediment monitoring on the river Danube started as early as the end of the 19th century, with scattered measurements carried out. Regular sediment sampling was developed in the first half of the 20th century all along the river, with different station density and monitoring frequencies in different countries. After the first few decades of regular sampling, the concept of (mainly industrial) development changed along the river and data needs changed as well, furthermore the complicated and inexact methods of sampling bed load on the alluvial reach of the river were not developed further. Frequency of suspended sediment sampling is very low along the river

  12. Neutron Activation Analysis of Soil Samples from Different Parts of Edirne in Turkey*

    NASA Astrophysics Data System (ADS)

    Zaim, N.; Dogan, C.; Camtakan, Z.

    2016-05-01

    The concentrations of constituent elements were determined in soil samples collected from different parts of the Maritza Basin, Edirne, Turkey. Neutron activation analysis, an extremely accurate technique, and the comparator method (using a standard) were applied for the first time in this region. After preparing the soil samples for neutron activation analysis, they were activated with thermal neutrons in a nuclear reactor, TRIGA-MARK II, at Istanbul Technical University. The activated samples were analyzed using a high-efficiency high-purity germanium detector, and gamma spectrometry was employed to determine the elemental concentration in the samples. Eight elements (chromium, manganese, cobalt, zinc, arsenic, molybdenum, cadmium, and barium) were qualitatively and quantitatively identified in 36 samples. The concentrations of some elements in the soil samples were high compared with values reported in the literature.

  13. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

    SciTech Connect

    Maxwell, S.; Noyes, G.; Culligan, B.

    2010-02-03

    A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

  14. Method for microRNA isolation from clinical serum samples.

    PubMed

    Li, Yu; Kowdley, Kris V

    2012-12-01

    MicroRNAs are a group of intracellular noncoding RNA molecules that have been implicated in a variety of human diseases. Because of their high stability in blood, microRNAs released into circulation could be potentially utilized as noninvasive biomarkers for diagnosis or prognosis. Current microRNA isolation protocols are specifically designed for solid tissues and are impractical for biomarker development utilizing small-volume serum samples on a large scale. Thus, a protocol for microRNA isolation from serum is needed to accommodate these conditions in biomarker development. To establish such a protocol, we developed a simplified approach to normalize sample input by using single synthetic spike-in microRNA. We evaluated three commonly used commercial microRNA isolation kits for the best performance by comparing RNA quality and yield. The manufacturer's protocol was further modified to improve the microRNA yield from 200μl of human serum. MicroRNAs isolated from a large set of clinical serum samples were tested on the miRCURY LNA real-time PCR panel and confirmed to be suitable for high-throughput microRNA profiling. In conclusion, we have established a proven method for microRNA isolation from clinical serum samples suitable for microRNA biomarker development.

  15. Hand held sample tube manipulator, system and method

    DOEpatents

    Kenny, Donald V [Liberty Township, OH; Smith, Deborah L [Liberty Township, OH; Severance, Richard A [late of Columbus, OH

    2001-01-01

    A manipulator apparatus, system and method for measuring analytes present in sample tubes. The manipulator apparatus includes a housing having a central bore with an inlet end and outlet end; a plunger mechanism with at least a portion thereof slideably disposed for reciprocal movement within the central bore, the plunger mechanism having a tubular gas channel with an inlet end and an outlet end, the gas channel inlet end disposed in the same direction as said inlet end of the central bore, wherein the inlet end of said plunger mechanism is adapted for movement so as to expel a sample tube inserted in the bore at the outlet end of the housing, the inlet end of the plunger mechanism is adapted for connection to gas supply; a first seal is disposed in the housing for sealing between the central bore and the plunger mechanism; a second seal is disposed at the outlet end of the housing for sealing between the central bore and a sample tube; a holder mounted on the housing for holding the sample tube; and a biasing mechanism for returning the plunger mechanism to a starting position.

  16. A time domain sampling method for inverse acoustic scattering problems

    NASA Astrophysics Data System (ADS)

    Guo, Yukun; Hömberg, Dietmar; Hu, Guanghui; Li, Jingzhi; Liu, Hongyu

    2016-06-01

    This work concerns the inverse scattering problems of imaging unknown/inaccessible scatterers by transient acoustic near-field measurements. Based on the analysis of the migration method, we propose efficient and effective sampling schemes for imaging small and extended scatterers from knowledge of time-dependent scattered data due to incident impulsive point sources. Though the inverse scattering problems are known to be nonlinear and ill-posed, the proposed imaging algorithms are totally "direct" involving only integral calculations on the measurement surface. Theoretical justifications are presented and numerical experiments are conducted to demonstrate the effectiveness and robustness of our methods. In particular, the proposed static imaging functionals enhance the performance of the total focusing method (TFM) and the dynamic imaging functionals show analogous behavior to the time reversal inversion but without solving time-dependent wave equations.

  17. A Novel Method for Sampling Alpha-Helical Protein Backbones

    DOE R&D Accomplishments Database

    Fain, Boris; Levitt, Michael

    2001-01-01

    We present a novel technique of sampling the configurations of helical proteins. Assuming knowledge of native secondary structure, we employ assembly rules gathered from a database of existing structures to enumerate the geometrically possible 3-D arrangements of the constituent helices. We produce a library of possible folds for 25 helical protein cores. In each case the method finds significant numbers of conformations close to the native structure. In addition we assign coordinates to all atoms for 4 of the 25 proteins. In the context of database driven exhaustive enumeration our method performs extremely well, yielding significant percentages of structures (0.02%--82%) within 6A of the native structure. The method's speed and efficiency make it a valuable contribution towards the goal of predicting protein structure.

  18. Path Sampling Methods for Enzymatic Quantum Particle Transfer Reactions.

    PubMed

    Dzierlenga, M W; Varga, M J; Schwartz, S D

    2016-01-01

    The mechanisms of enzymatic reactions are studied via a host of computational techniques. While previous methods have been used successfully, many fail to incorporate the full dynamical properties of enzymatic systems. This can lead to misleading results in cases where enzyme motion plays a significant role in the reaction coordinate, which is especially relevant in particle transfer reactions where nuclear tunneling may occur. In this chapter, we outline previous methods, as well as discuss newly developed dynamical methods to interrogate mechanisms of enzymatic particle transfer reactions. These new methods allow for the calculation of free energy barriers and kinetic isotope effects (KIEs) with the incorporation of quantum effects through centroid molecular dynamics (CMD) and the full complement of enzyme dynamics through transition path sampling (TPS). Recent work, summarized in this chapter, applied the method for calculation of free energy barriers to reaction in lactate dehydrogenase (LDH) and yeast alcohol dehydrogenase (YADH). We found that tunneling plays an insignificant role in YADH but plays a more significant role in LDH, though not dominant over classical transfer. Additionally, we summarize the application of a TPS algorithm for the calculation of reaction rates in tandem with CMD to calculate the primary H/D KIE of YADH from first principles. We found that the computationally obtained KIE is within the margin of error of experimentally determined KIEs and corresponds to the KIE of particle transfer in the enzyme. These methods provide new ways to investigate enzyme mechanism with the inclusion of protein and quantum dynamics.

  19. Path Sampling Methods for Enzymatic Quantum Particle Transfer Reactions.

    PubMed

    Dzierlenga, M W; Varga, M J; Schwartz, S D

    2016-01-01

    The mechanisms of enzymatic reactions are studied via a host of computational techniques. While previous methods have been used successfully, many fail to incorporate the full dynamical properties of enzymatic systems. This can lead to misleading results in cases where enzyme motion plays a significant role in the reaction coordinate, which is especially relevant in particle transfer reactions where nuclear tunneling may occur. In this chapter, we outline previous methods, as well as discuss newly developed dynamical methods to interrogate mechanisms of enzymatic particle transfer reactions. These new methods allow for the calculation of free energy barriers and kinetic isotope effects (KIEs) with the incorporation of quantum effects through centroid molecular dynamics (CMD) and the full complement of enzyme dynamics through transition path sampling (TPS). Recent work, summarized in this chapter, applied the method for calculation of free energy barriers to reaction in lactate dehydrogenase (LDH) and yeast alcohol dehydrogenase (YADH). We found that tunneling plays an insignificant role in YADH but plays a more significant role in LDH, though not dominant over classical transfer. Additionally, we summarize the application of a TPS algorithm for the calculation of reaction rates in tandem with CMD to calculate the primary H/D KIE of YADH from first principles. We found that the computationally obtained KIE is within the margin of error of experimentally determined KIEs and corresponds to the KIE of particle transfer in the enzyme. These methods provide new ways to investigate enzyme mechanism with the inclusion of protein and quantum dynamics. PMID:27497161

  20. Survey of predators and sampling method comparison in sweet corn.

    PubMed

    Musser, Fred R; Nyrop, Jan P; Shelton, Anthony M

    2004-02-01

    Natural predation is an important component of integrated pest management that is often overlooked because it is difficult to quantify and perceived to be unreliable. To begin incorporating natural predation into sweet corn, Zea mays L., pest management, a predator survey was conducted and then three sampling methods were compared for their ability to accurately monitor the most abundant predators. A predator survey on sweet corn foliage in New York between 1999 and 2001 identified 13 species. Orius insidiosus (Say), Coleomegilla maculata (De Geer), and Harmonia axyridis (Pallas) were the most numerous predators in all years. To determine the best method for sampling adult and immature stages of these predators, comparisons were made among nondestructive field counts, destructive counts, and yellow sticky cards. Field counts were correlated with destructive counts for all populations, but field counts of small insects were biased. Sticky cards underrepresented immature populations. Yellow sticky cards were more attractive to C. maculata adults than H. axyridis adults, especially before pollen shed, making coccinellid population estimates based on sticky cards unreliable. Field counts were the most precise method for monitoring adult and immature stages of the three major predators. Future research on predicting predation of pests in sweet corn should be based on field counts of predators because these counts are accurate, have no associated supply costs, and can be made quickly. PMID:14998137

  1. Vadose Zone Sampling Methods for Detection of Preferential Pesticides Transport

    NASA Astrophysics Data System (ADS)

    Peranginangin, N.; Richards, B. K.; Steenhuis, T. S.

    2003-12-01

    Leaching of agricultural applied chemicals through the vadose zone is a major cause for the occurrence of agrichemicals in groundwater. Accurate soil water sampling methods are needed to ensure meaningful monitoring results, especially for soils that have significant preferential flow paths. The purpose of this study was to assess the capability and the effectiveness of various soil water sampling methods in detecting preferential transport of pesticides in a strongly-structured silty clay loam (Hudson series) soil. Soil water sampling devices tested were wick pan and gravity pan lysimeters, tile lines, porous ceramic cups, and pipe lysimeters; all installed at 45 to105 cm depth below the ground surface. A reasonable worse-case scenario was tested by applying a simulated rain storm soon after pesticides were sprayed at agronomic rates. Herbicides atrazine (6-chloro-N2-ethyl-N4-isopropyl-1,3,5-triazine-2,4-diamine) and 2,4-D (2,4-dichloro-phenoxyacetic acid) were chosen as model compounds. Chloride (KCl) tracer was used to determine spatial and temporal distribution of non-reactive solute and water as well as a basis for determining the retardation in pesticides movement. Results show that observed pesticide mobility was much greater than would be predicted by uniform flow. Under relatively high soil moisture conditions, gravity and wick pan lysimeters had comparably good collection efficiencies, whereas the wick samplers had an advantage over gravity driven sampler when the soil moisture content was below field capacity. Pipe lysimeters had breakthrough patterns that were similar to pan samplers. At small plot scale, tile line samplers tended to underestimate solute concentration because of water dilution around the samplers. The use of porous cup samplers performed poorly because of their sensitivity to local profile characteristics: only by chance can they intercept and sample the preferential flow paths that are critical to transport. Wick sampler had the least

  2. Several methods for concentrating bacteria in fluid samples

    NASA Technical Reports Server (NTRS)

    Thomas, R. R.

    1976-01-01

    The sensitivities of the firefly luciferase - ATP flow system and luminol flow system were established as 300,000 E. coli per milliliter and 10,000 E. coli per milliliter respectively. To achieve the detection limit of 1,000 bacteria per milliliter previously established, a method of concentrating microorganisms using a sartorius membrane filter system is investigated. Catalase in 50% ethanol is found to be a stable luminol standard and can be used up to 24 hours with only a 10% loss of activity. The luminol reagent is also stable over a 24 hour period. A method of preparing relatively inexpensive luciferase from desiccated firefly tails is developed.

  3. Drum plug piercing and sampling device and method

    DOEpatents

    Counts, Kevin T.

    2011-04-26

    An apparatus and method for piercing a drum plug of a drum in order to sample and/or vent gases that may accumulate in a space of the drum is provided. The drum is not damaged and can be reused since the pierced drum plug can be subsequently replaced. The apparatus includes a frame that is configured for engagement with the drum. A cylinder actuated by a fluid is mounted to the frame. A piercer is placed into communication with the cylinder so that actuation of the cylinder causes the piercer to move in a linear direction so that the piercer may puncture the drum plug of the drum.

  4. Methods of scaling threshold color difference using printed samples

    NASA Astrophysics Data System (ADS)

    Huang, Min; Cui, Guihua; Liu, Haoxue; Luo, M. Ronnier

    2012-01-01

    A series of printed samples on substrate of semi-gloss paper and with the magnitude of threshold color difference were prepared for scaling the visual color difference and to evaluate the performance of different method. The probabilities of perceptibly was used to normalized to Z-score and different color differences were scaled to the Z-score. The visual color difference was got, and checked with the STRESS factor. The results indicated that only the scales have been changed but the relative scales between pairs in the data are preserved.

  5. Generalized Jones matrix method for homogeneous biaxial samples.

    PubMed

    Ortega-Quijano, Noé; Fade, Julien; Alouini, Mehdi

    2015-08-10

    The generalized Jones matrix (GJM) is a recently introduced tool to describe linear transformations of three-dimensional light fields. Based on this framework, a specific method for obtaining the GJM of uniaxial anisotropic media was recently presented. However, the GJM of biaxial media had not been tackled so far, as the previous method made use of a simplified rotation matrix that lacks a degree of freedom in the three-dimensional rotation, thus being not suitable for calculating the GJM of biaxial media. In this work we propose a general method to derive the GJM of arbitrarily-oriented homogeneous biaxial media. It is based on the differential generalized Jones matrix (dGJM), which is the three-dimensional counterpart of the conventional differential Jones matrix. We show that the dGJM provides a simple and elegant way to describe uniaxial and biaxial media, with the capacity to model multiple simultaneous optical effects. The practical usefulness of this method is illustrated by the GJM modeling of the polarimetric properties of a negative uniaxial KDP crystal and a biaxial KTP crystal for any three-dimensional sample orientation. The results show that this method constitutes an advantageous and straightforward way to model biaxial media, which show a growing relevance for many interesting applications.

  6. A microRNA isolation method from clinical samples

    PubMed Central

    Zununi Vahed, Sepideh; Barzegari, Abolfazl; Rahbar Saadat, Yalda; Mohammadi, Somayeh; Samadi, Nasser

    2016-01-01

    Introduction: microRNAs (miRNAs) are considered to be novel molecular biomakers that could be exploited in the diagnosis and treatment of different diseases. The present study aimed to develop an efficient miRNA isolation method from different clinical specimens. Methods: Total RNAs were isolated by Trizol reagent followed by precipitation of the large RNAs with potassium acetate (KCH3COOH), polyethylene glycol (PEG) 4000 and 6000, and lithium chloride (LiCl). Then, small RNAs were enriched and recovered from the supernatants by applying a combination of LiCl and ethanol. The efficiency of the method was evaluated through the quality, quantity, and integrity of the recovered RNAs using the A260/280 absorbance ratio, reverse transcription PCR (RT-PCR), and quantitative real-time PCR (q-PCR). Results: Comparison of different RNA isolation methods based on the precipitation of DNA and large RNAs, high miRNA recovery and PCR efficiency revealed that applying potassium acetate with final precipitation of small RNAs using 2.5 M LiCl plus ethanol can provide high yield and quality small RNAs that can be exploited for clinical purposes. Conclusion: The current isolation method can be applied for most clinical samples including cells, formalin-fixed and paraffin-embedded (FFPE) tissues and even body fluids with a wide applicability in molecular biology investigations. PMID:27340621

  7. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

    SciTech Connect

    DOUGLAS JG; MEZNARICH HD, PHD; OLSEN JR; ROSS GA; STAUFFER M

    2008-09-30

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S&GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S&GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively

  8. An emergency radiobioassay method for 226Ra in human urine samples.

    PubMed

    Sadi, Baki B; Li, Chunsheng; Kramer, Gary H

    2012-08-01

    A new radioanalytical method was developed for rapid determination of (226)Ra in human urine samples. The method is based on organic removal and decolourisation of a urine sample by a polymeric (acrylic ester) solid phase sorbent material followed by extraction and preconcentration of (226)Ra in an organic solvent using a dispersive liquid-liquid microextraction technique. Radiometric measurement of (226)Ra was carried out using a liquid scintillation counting instrument. The minimum detectable activity for the method (0.15 Bq l(-1)) is lower than the required sensitivity of 0.2 Bq l(-1) for (226)Ra in human urine samples as defined in the requirements for radiation emergency bioassay techniques for the public and first responders based on the dose threshold for possible medical attention recommended by the International Commission on Radiological Protection (ICRP). The accuracy (expressed as relative bias, B(r)) and repeatability of the method (expressed as relative precision, S(B)) evaluated at the reference level (2 Bq l(-1)) were found to be -4.5 and 2.6 %, respectively. The sample turnaround time was <5 h for a single urine sample and <20 h for a batch of six urine samples. With the fast sample turnaround time combined with the potential to carry out the analysis in a field deployable mobile laboratory, the newly developed method can be used for emergency radiobioassay of (226)Ra in human urine samples following a radiological or nuclear accident.

  9. Eigenvector method for umbrella sampling enables error analysis

    NASA Astrophysics Data System (ADS)

    Thiede, Erik H.; Van Koten, Brian; Weare, Jonathan; Dinner, Aaron R.

    2016-08-01

    Umbrella sampling efficiently yields equilibrium averages that depend on exploring rare states of a model by biasing simulations to windows of coordinate values and then combining the resulting data with physical weighting. Here, we introduce a mathematical framework that casts the step of combining the data as an eigenproblem. The advantage to this approach is that it facilitates error analysis. We discuss how the error scales with the number of windows. Then, we derive a central limit theorem for averages that are obtained from umbrella sampling. The central limit theorem suggests an estimator of the error contributions from individual windows, and we develop a simple and computationally inexpensive procedure for implementing it. We demonstrate this estimator for simulations of the alanine dipeptide and show that it emphasizes low free energy pathways between stable states in comparison to existing approaches for assessing error contributions. Our work suggests the possibility of using the estimator and, more generally, the eigenvector method for umbrella sampling to guide adaptation of the simulation parameters to accelerate convergence.

  10. Eigenvector method for umbrella sampling enables error analysis.

    PubMed

    Thiede, Erik H; Van Koten, Brian; Weare, Jonathan; Dinner, Aaron R

    2016-08-28

    Umbrella sampling efficiently yields equilibrium averages that depend on exploring rare states of a model by biasing simulations to windows of coordinate values and then combining the resulting data with physical weighting. Here, we introduce a mathematical framework that casts the step of combining the data as an eigenproblem. The advantage to this approach is that it facilitates error analysis. We discuss how the error scales with the number of windows. Then, we derive a central limit theorem for averages that are obtained from umbrella sampling. The central limit theorem suggests an estimator of the error contributions from individual windows, and we develop a simple and computationally inexpensive procedure for implementing it. We demonstrate this estimator for simulations of the alanine dipeptide and show that it emphasizes low free energy pathways between stable states in comparison to existing approaches for assessing error contributions. Our work suggests the possibility of using the estimator and, more generally, the eigenvector method for umbrella sampling to guide adaptation of the simulation parameters to accelerate convergence. PMID:27586912

  11. Method for testing earth samples for contamination by organic contaminants

    DOEpatents

    Schabron, John F.

    1996-01-01

    Provided is a method for testing earth samples for contamination by organic contaminants, and particularly for aromatic compounds such as those found in diesel fuel and other heavy fuel oils, kerosene, creosote, coal oil, tars and asphalts. A drying step is provided in which a drying agent is contacted with either the earth sample or a liquid extract phase to reduce to possibility of false indications of contamination that could occur when humic material is present in the earth sample. This is particularly a problem when using relatively safe, non-toxic and inexpensive polar solvents such as isopropyl alcohol since the humic material tends to be very soluble in those solvents when water is present. Also provided is an ultraviolet spectroscopic measuring technique for obtaining an indication as to whether a liquid extract phase contains aromatic organic contaminants. In one embodiment, the liquid extract phase is subjected to a narrow and discrete band of radiation including a desired wave length and the ability of the liquid extract phase to absorb that wavelength of ultraviolet radiation is measured to provide an indication of the presence of aromatic organic contaminants.

  12. Method for testing earth samples for contamination by organic contaminants

    DOEpatents

    Schabron, J.F.

    1996-10-01

    Provided is a method for testing earth samples for contamination by organic contaminants, and particularly for aromatic compounds such as those found in diesel fuel and other heavy fuel oils, kerosene, creosote, coal oil, tars and asphalts. A drying step is provided in which a drying agent is contacted with either the earth sample or a liquid extract phase to reduce to possibility of false indications of contamination that could occur when humic material is present in the earth sample. This is particularly a problem when using relatively safe, non-toxic and inexpensive polar solvents such as isopropyl alcohol since the humic material tends to be very soluble in those solvents when water is present. Also provided is an ultraviolet spectroscopic measuring technique for obtaining an indication as to whether a liquid extract phase contains aromatic organic contaminants. In one embodiment, the liquid extract phase is subjected to a narrow and discrete band of radiation including a desired wave length and the ability of the liquid extract phase to absorb that wavelength of ultraviolet radiation is measured to provide an indication of the presence of aromatic organic contaminants. 2 figs.

  13. Antimicrobial activity of propolis samples from two different regions of Anatolia.

    PubMed

    Kartal, Murat; Yildiz, Sulhiye; Kaya, Serdar; Kurucu, Semra; Topçu, Gülaçti

    2003-05-01

    Antimicrobial activity of two propolis samples from Kazan and Marmaris regions in Turkey were investigated by the disc diffusion method. Antimicrobial activity was tested with four different ethanolic extracts (30, 50, 70, and 96% ethanol) of each sample against seven Gram positive, four Gram negative bacteria and one fungus culture. The activity was found to be mainly due to caffeic acid and its esters. An isomeric mixture containing 3,3-dimethylallyl caffeate, and isopent-3-enyl caffeate was isolated from Kazan propolis samples.

  14. BMAA extraction of cyanobacteria samples: which method to choose?

    PubMed

    Lage, Sandra; Burian, Alfred; Rasmussen, Ulla; Costa, Pedro Reis; Annadotter, Heléne; Godhe, Anna; Rydberg, Sara

    2016-01-01

    β-N-Methylamino-L-alanine (BMAA), a neurotoxin reportedly produced by cyanobacteria, diatoms and dinoflagellates, is proposed to be linked to the development of neurological diseases. BMAA has been found in aquatic and terrestrial ecosystems worldwide, both in its phytoplankton producers and in several invertebrate and vertebrate organisms that bioaccumulate it. LC-MS/MS is the most frequently used analytical technique in BMAA research due to its high selectivity, though consensus is lacking as to the best extraction method to apply. This study accordingly surveys the efficiency of three extraction methods regularly used in BMAA research to extract BMAA from cyanobacteria samples. The results obtained provide insights into possible reasons for the BMAA concentration discrepancies in previous publications. In addition and according to the method validation guidelines for analysing cyanotoxins, the TCA protein precipitation method, followed by AQC derivatization and LC-MS/MS analysis, is now validated for extracting protein-bound (after protein hydrolysis) and free BMAA from cyanobacteria matrix. BMAA biological variability was also tested through the extraction of diatom and cyanobacteria species, revealing a high variance in BMAA levels (0.0080-2.5797 μg g(-1) DW).

  15. Comparative study of activation analyses for the determination of trace halogens in geological and cosmochemical samples.

    PubMed

    Nakamoto, Tomoshi; Oura, Yasuji; Ebihara, Mitsuru

    2007-09-01

    Halogens (fluorine, chlorine, bromine and iodine) were determined by activation analyses (neutron activation analysis (NAA), photon activation analysis (PAA) and prompt gamma-ray analysis (PGA)) for geological and cosmochemical solid samples. We studied how each analytical method was for the determination of trace amounts of halogens in rock samples. Radiochemical NAA (RNAA) showed the highest analytical reliability for three halogens (chlorine, bromine and iodine), whereas a set of four halogens (fluorine, chlorine, bromine and iodine) could be determined in principle by radiochemical PAA (RPAA) from a single specimen. Although it is a non-destructive method, PGA showed an analytical sensitivity for chlorine comparable to those of RNAA and RPAA.

  16. Automated Aqueous Sample Concentration Methods for in situ Astrobiological Instrumentation

    NASA Astrophysics Data System (ADS)

    Aubrey, A. D.; Grunthaner, F. J.

    2009-12-01

    The era of wet chemical experiments for in situ planetary science investigations is upon us, as evidenced by recent results from the surface of Mars by Phoenix’s microscopy, electrochemistry, and conductivity analyzer, MECA [1]. Studies suggest that traditional thermal volatilization methods for planetary science in situ investigations induce organic degradation during sample processing [2], an effect that is enhanced in the presence of oxidants [3]. Recent developments have trended towards adaptation of non-destructive aqueous extraction and analytical methods for future astrobiological instrumentation. Wet chemical extraction techniques under investigation include subcritical water extraction, SCWE [4], aqueous microwave assisted extraction, MAE, and organic solvent extraction [5]. Similarly, development of miniaturized analytical space flight instruments that require aqueous extracts include microfluidic capillary electrophoresis chips, μCE [6], liquid-chromatography mass-spectrometrometers, LC-MS [7], and life marker chips, LMC [8]. If organics are present on the surface of Mars, they are expected to be present at extremely low concentrations (parts-per-billion), orders of magnitude below the sensitivities of most flight instrument technologies. Therefore, it becomes necessary to develop and integrate concentration mechanisms for in situ sample processing before delivery to analytical flight instrumentation. We present preliminary results of automated solid-phase-extraction (SPE) sample purification and concentration methods for the treatment of highly saline aqueous soil extracts. These methods take advantage of the affinity of low molecular weight organic compounds with natural and synthetic scavenger materials. These interactions allow for the separation of target organic analytes from unfavorable background species (i.e. salts) during inline treatment, and a clever method for selective desorption is utilized to obtain concentrated solutions on the order

  17. A Work Sampling Study of Provider Activities in School-Based Health Centers

    ERIC Educational Resources Information Center

    Mavis, Brian; Pearson, Rachel; Stewart, Gail; Keefe, Carole

    2009-01-01

    Background: The purpose of this study was to describe provider activities in a convenience sample of School-Based Health Centers (SBHCs). The goal was to determine the relative proportion of time that clinic staff engaged in various patient care and non-patient care activities. Methods: All provider staff at 4 urban SBHCs participated in this…

  18. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such...

  19. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such...

  20. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such...

  1. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such...

  2. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such...

  3. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... form and consistency of the waste materials to be sampled. Samples collected using the sampling... Crushed or powdered material—ASTM Standard D346-75 Soil or rock-like material—ASTM Standard D420-69...

  4. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... form and consistency of the waste materials to be sampled. Samples collected using the sampling... Crushed or powdered material—ASTM Standard D346-75 Soil or rock-like material—ASTM Standard D420-69...

  5. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  6. Method of remotely characterizing thermal properties of a sample

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S. (Inventor); Heath, D. Michele (Inventor); Welch, Christopher (Inventor); Winfree, William P. (Inventor); Miller, William E. (Inventor)

    1992-01-01

    A sample in a wind tunnel is radiated from a thermal energy source outside of the wind tunnel. A thermal imager system, also located outside of the wind tunnel, reads surface radiations from the sample as a function of time. The produced thermal images are characteristic of the heat transferred from the sample to the flow across the sample. In turn, the measured rates of heat loss of the sample are characteristic of the flow and the sample.

  7. Clustering Methods with Qualitative Data: a Mixed-Methods Approach for Prevention Research with Small Samples.

    PubMed

    Henry, David; Dymnicki, Allison B; Mohatt, Nathaniel; Allen, James; Kelly, James G

    2015-10-01

    Qualitative methods potentially add depth to prevention research but can produce large amounts of complex data even with small samples. Studies conducted with culturally distinct samples often produce voluminous qualitative data but may lack sufficient sample sizes for sophisticated quantitative analysis. Currently lacking in mixed-methods research are methods allowing for more fully integrating qualitative and quantitative analysis techniques. Cluster analysis can be applied to coded qualitative data to clarify the findings of prevention studies by aiding efforts to reveal such things as the motives of participants for their actions and the reasons behind counterintuitive findings. By clustering groups of participants with similar profiles of codes in a quantitative analysis, cluster analysis can serve as a key component in mixed-methods research. This article reports two studies. In the first study, we conduct simulations to test the accuracy of cluster assignment using three different clustering methods with binary data as produced when coding qualitative interviews. Results indicated that hierarchical clustering, K-means clustering, and latent class analysis produced similar levels of accuracy with binary data and that the accuracy of these methods did not decrease with samples as small as 50. Whereas the first study explores the feasibility of using common clustering methods with binary data, the second study provides a "real-world" example using data from a qualitative study of community leadership connected with a drug abuse prevention project. We discuss the implications of this approach for conducting prevention research, especially with small samples and culturally distinct communities.

  8. Clustering Methods with Qualitative Data: A Mixed Methods Approach for Prevention Research with Small Samples

    PubMed Central

    Henry, David; Dymnicki, Allison B.; Mohatt, Nathaniel; Allen, James; Kelly, James G.

    2016-01-01

    Qualitative methods potentially add depth to prevention research, but can produce large amounts of complex data even with small samples. Studies conducted with culturally distinct samples often produce voluminous qualitative data, but may lack sufficient sample sizes for sophisticated quantitative analysis. Currently lacking in mixed methods research are methods allowing for more fully integrating qualitative and quantitative analysis techniques. Cluster analysis can be applied to coded qualitative data to clarify the findings of prevention studies by aiding efforts to reveal such things as the motives of participants for their actions and the reasons behind counterintuitive findings. By clustering groups of participants with similar profiles of codes in a quantitative analysis, cluster analysis can serve as a key component in mixed methods research. This article reports two studies. In the first study, we conduct simulations to test the accuracy of cluster assignment using three different clustering methods with binary data as produced when coding qualitative interviews. Results indicated that hierarchical clustering, K-Means clustering, and latent class analysis produced similar levels of accuracy with binary data, and that the accuracy of these methods did not decrease with samples as small as 50. Whereas the first study explores the feasibility of using common clustering methods with binary data, the second study provides a “real-world” example using data from a qualitative study of community leadership connected with a drug abuse prevention project. We discuss the implications of this approach for conducting prevention research, especially with small samples and culturally distinct communities. PMID:25946969

  9. Markov chain Monte Carlo posterior sampling with the Hamiltonian method.

    SciTech Connect

    Hanson, Kenneth M.

    2001-01-01

    A major advantage of Bayesian data analysis is that provides a characterization of the uncertainty in the model parameters estimated from a given set of measurements in the form of a posterior probability distribution. When the analysis involves a complicated physical phenomenon, the posterior may not be available in analytic form, but only calculable by means of a simulation code. In such cases, the uncertainty in inferred model parameters requires characterization of a calculated functional. An appealing way to explore the posterior, and hence characterize the uncertainty, is to employ the Markov Chain Monte Carlo technique. The goal of MCMC is to generate a sequence random of parameter x samples from a target pdf (probability density function), {pi}(x). In Bayesian analysis, this sequence corresponds to a set of model realizations that follow the posterior distribution. There are two basic MCMC techniques. In Gibbs sampling, typically one parameter is drawn from the conditional pdf at a time, holding all others fixed. In the Metropolis algorithm, all the parameters can be varied at once. The parameter vector is perturbed from the current sequence point by adding a trial step drawn randomly from a symmetric pdf. The trial position is either accepted or rejected on the basis of the probability at the trial position relative to the current one. The Metropolis algorithm is often employed because of its simplicity. The aim of this work is to develop MCMC methods that are useful for large numbers of parameters, n, say hundreds or more. In this regime the Metropolis algorithm can be unsuitable, because its efficiency drops as 0.3/n. The efficiency is defined as the reciprocal of the number of steps in the sequence needed to effectively provide a statistically independent sample from {pi}.

  10. Assessment of anti-Salmonella activity of boot dip samples.

    PubMed

    Rabie, André J; McLaren, Ian M; Breslin, Mark F; Sayers, Robin; Davies, Rob H

    2015-01-01

    The introduction of pathogens from the external environment into poultry houses via the boots of farm workers and visitors presents a significant risk. The use of boot dips containing disinfectant to help prevent this from happening is common practice, but the effectiveness of these boot dips as a preventive measure can vary. The aim of this study was to assess the anti-Salmonella activity of boot dips that are being used on poultry farms. Boot dip samples were collected from commercial laying hen farms in the UK and tested within 24 hours of receipt at the laboratory to assess their anti-Salmonella activity. All boot dip samples were tested against a field strain of Salmonella enterica serovar Enteritidis using three test models: pure culture, paper disc surface matrix and yeast suspension model. Of the 112 boot dip samples tested 83.6% were effective against Salmonella in pure culture, 37.3% in paper disc surface matrix and 44.5% in yeast suspension model. Numerous factors may influence the efficacy of the disinfectants. Disinfectants used in the dips may not always be fully active against surface or organic matter contamination; they may be inaccurately measured or diluted to a concentration other than that specified or recommended; dips may not be changed regularly or may have been exposed to rain and other environmental elements. This study showed that boot dips in use on poultry farms are frequently ineffective. PMID:25650744

  11. A comparison of methods for representing sparsely sampled random quantities.

    SciTech Connect

    Romero, Vicente Jose; Swiler, Laura Painton; Urbina, Angel; Mullins, Joshua

    2013-09-01

    This report discusses the treatment of uncertainties stemming from relatively few samples of random quantities. The importance of this topic extends beyond experimental data uncertainty to situations involving uncertainty in model calibration, validation, and prediction. With very sparse data samples it is not practical to have a goal of accurately estimating the underlying probability density function (PDF). Rather, a pragmatic goal is that the uncertainty representation should be conservative so as to bound a specified percentile range of the actual PDF, say the range between 0.025 and .975 percentiles, with reasonable reliability. A second, opposing objective is that the representation not be overly conservative; that it minimally over-estimate the desired percentile range of the actual PDF. The presence of the two opposing objectives makes the sparse-data uncertainty representation problem interesting and difficult. In this report, five uncertainty representation techniques are characterized for their performance on twenty-one test problems (over thousands of trials for each problem) according to these two opposing objectives and other performance measures. Two of the methods, statistical Tolerance Intervals and a kernel density approach specifically developed for handling sparse data, exhibit significantly better overall performance than the others.

  12. A Method For Parallel, Automated, Thermal Cycling of Submicroliter Samples

    PubMed Central

    Nakane, Jonathan; Broemeling, David; Donaldson, Roger; Marziali, Andre; Willis, Thomas D.; O'Keefe, Matthew; Davis, Ronald W.

    2001-01-01

    A large fraction of the cost of DNA sequencing and other DNA-analysis processes results from the reagent costs incurred during cycle sequencing or PCR. In particular, the high cost of the enzymes and dyes used in these processes often results in thermal cycling costs exceeding $0.50 per sample. In the case of high-throughput DNA sequencing, this is a significant and unnecessary expense. Improved detection efficiency of new sequencing instrumentation allows the reaction volumes for cycle sequencing to be scaled down to one-tenth of presently used volumes, resulting in at least a 10-fold decrease in the cost of this process. However, commercially available thermal cyclers and automated reaction setup devices have inherent design limitations which make handling volumes of <1 μL extremely difficult. In this paper, we describe a method for thermal cycling aimed at reliable, automated cycling of submicroliter reaction volumes. PMID:11230168

  13. COMPARISON OF SAMPLING METHODS FOR SEMI-VOLATILE ORGANIC CARBON ASSOCIATED WITH PM 2.5

    EPA Science Inventory

    This study evaluates the influence of denuder sampling methods and filter collection media on the measurement of semi-volatile organic carbon (SVOC) associated with PM2.5. Two types of collection media, charcoal (activated carbon) and XAD, were used both in diffusion denuders ...

  14. MARKOV CHAIN MONTE CARLO POSTERIOR SAMPLING WITH THE HAMILTONIAN METHOD

    SciTech Connect

    K. HANSON

    2001-02-01

    The Markov Chain Monte Carlo technique provides a means for drawing random samples from a target probability density function (pdf). MCMC allows one to assess the uncertainties in a Bayesian analysis described by a numerically calculated posterior distribution. This paper describes the Hamiltonian MCMC technique in which a momentum variable is introduced for each parameter of the target pdf. In analogy to a physical system, a Hamiltonian H is defined as a kinetic energy involving the momenta plus a potential energy {var_phi}, where {var_phi} is minus the logarithm of the target pdf. Hamiltonian dynamics allows one to move along trajectories of constant H, taking large jumps in the parameter space with relatively few evaluations of {var_phi} and its gradient. The Hamiltonian algorithm alternates between picking a new momentum vector and following such trajectories. The efficiency of the Hamiltonian method for multidimensional isotropic Gaussian pdfs is shown to remain constant at around 7% for up to several hundred dimensions. The Hamiltonian method handles correlations among the variables much better than the standard Metropolis algorithm. A new test, based on the gradient of {var_phi}, is proposed to measure the convergence of the MCMC sequence.

  15. Martian Radiative Transfer Modeling Using the Optimal Spectral Sampling Method

    NASA Technical Reports Server (NTRS)

    Eluszkiewicz, J.; Cady-Pereira, K.; Uymin, G.; Moncet, J.-L.

    2005-01-01

    The large volume of existing and planned infrared observations of Mars have prompted the development of a new martian radiative transfer model that could be used in the retrievals of atmospheric and surface properties. The model is based on the Optimal Spectral Sampling (OSS) method [1]. The method is a fast and accurate monochromatic technique applicable to a wide range of remote sensing platforms (from microwave to UV) and was originally developed for the real-time processing of infrared and microwave data acquired by instruments aboard the satellites forming part of the next-generation global weather satellite system NPOESS (National Polarorbiting Operational Satellite System) [2]. As part of our on-going research related to the radiative properties of the martian polar caps, we have begun the development of a martian OSS model with the goal of using it to perform self-consistent atmospheric corrections necessary to retrieve caps emissivity from the Thermal Emission Spectrometer (TES) spectra. While the caps will provide the initial focus area for applying the new model, it is hoped that the model will be of interest to the wider Mars remote sensing community.

  16. Determination of rare-earth elements in Luna 16 regolith sample by chemical spectral method

    NASA Technical Reports Server (NTRS)

    Stroganova, N. S.; Ryabukhin, V. A.; Laktinova, N. V.; Ageyeva, L. V.; Galkina, I. P.; Gatinskaya, N. G.; Yermakov, A. N.; Karyakin, A. V.

    1974-01-01

    An analysis was made of regolith from layer A of the Luna 16 sample for rare earth elements, by a chemical spectral method. Chemical and ion exchange concentrations were used to determine the content of 12 elements and Y at the level 0.001 to 0.0001 percent with 10 to 15 percent reproducibility of the emission determination. Results within the limits of reproducibility agree with data obtained by mass spectra, activation, and X-ray fluorescent methods.

  17. Sequential sampling: a novel method in farm animal welfare assessment.

    PubMed

    Heath, C A E; Main, D C J; Mullan, S; Haskell, M J; Browne, W J

    2016-02-01

    Lameness in dairy cows is an important welfare issue. As part of a welfare assessment, herd level lameness prevalence can be estimated from scoring a sample of animals, where higher levels of accuracy are associated with larger sample sizes. As the financial cost is related to the number of cows sampled, smaller samples are preferred. Sequential sampling schemes have been used for informing decision making in clinical trials. Sequential sampling involves taking samples in stages, where sampling can stop early depending on the estimated lameness prevalence. When welfare assessment is used for a pass/fail decision, a similar approach could be applied to reduce the overall sample size. The sampling schemes proposed here apply the principles of sequential sampling within a diagnostic testing framework. This study develops three sequential sampling schemes of increasing complexity to classify 80 fully assessed UK dairy farms, each with known lameness prevalence. Using the Welfare Quality herd-size-based sampling scheme, the first 'basic' scheme involves two sampling events. At the first sampling event half the Welfare Quality sample size is drawn, and then depending on the outcome, sampling either stops or is continued and the same number of animals is sampled again. In the second 'cautious' scheme, an adaptation is made to ensure that correctly classifying a farm as 'bad' is done with greater certainty. The third scheme is the only scheme to go beyond lameness as a binary measure and investigates the potential for increasing accuracy by incorporating the number of severely lame cows into the decision. The three schemes are evaluated with respect to accuracy and average sample size by running 100 000 simulations for each scheme, and a comparison is made with the fixed size Welfare Quality herd-size-based sampling scheme. All three schemes performed almost as well as the fixed size scheme but with much smaller average sample sizes. For the third scheme, an overall

  18. Probing methane hydrate nucleation through the forward flux sampling method.

    PubMed

    Bi, Yuanfei; Li, Tianshu

    2014-11-26

    Understanding the nucleation of hydrate is the key to developing effective strategies for controlling methane hydrate formation. Here we present a computational study of methane hydrate nucleation, by combining the forward flux sampling (FFS) method and the coarse-grained water model mW. To facilitate the application of FFS in studying the formation of methane hydrate, we developed an effective order parameter λ on the basis of the topological analysis of the tetrahedral network. The order parameter capitalizes the signature of hydrate structure, i.e., polyhedral cages, and is capable of efficiently distinguishing hydrate from ice and liquid water while allowing the formation of different hydrate phases, i.e., sI, sII, and amorphous. Integration of the order parameter λ with FFS allows explicitly computing hydrate nucleation rates and obtaining an ensemble of nucleation trajectories under conditions where spontaneous hydrate nucleation becomes too slow to occur in direct simulation. The convergence of the obtained hydrate nucleation rate was found to depend crucially on the convergence of the spatial distribution for the spontaneously formed hydrate seeds obtained from the initial sampling of FFS. The validity of the approach is also verified by the agreement between the calculated nucleation rate and that inferred from the direct simulation. Analyzing the obtained large ensemble of hydrate nucleation trajectories, we show hydrate formation at 220 K and 500 bar is initiated by the nucleation events occurring in the vicinity of water-methane interface, and facilitated by a gradual transition from amorphous to crystalline structure. The latter provides the direct support to the proposed two-step nucleation mechanism of methane hydrate. PMID:24849698

  19. COMPARISON OF USEPA FIELD SAMPLING METHODS FOR BENTHIC MACROINVERTEBRATE STUDIES

    EPA Science Inventory

    Two U.S. Environmental Protection Agency (USEPA) macroinvertebrate sampling protocols were compared in the Mid-Atlantic Highlands region. The Environmental Monitoring and Assessment Program (EMAP) wadeable streams protocol results in a single composite sample from nine transects...

  20. A rapid method for the determination of honey diastase activity.

    PubMed

    Sakač, Nikola; Sak-Bosnar, Milan

    2012-05-15

    A new rapid method for the determination of honey diastase activity using direct potentiometric principles has been proposed. A platinum redox sensor has been used to quantify the amount of free triiodide released from a starch triiodide complex after starch hydrolysis by honey diastase. The method was tested on honey samples with varying diastase activities. The first 5 min of data for each sample were used for linear regression analysis in order to calculate diastase activity. The new method was compared with classical Schade and commercial Phadebas procedures. The results showed good correlations with both methods and offered a simple method for unit conversion to DN units for diastase activity, making the method suitable for routine analysis.

  1. Improving the replica-exchange molecular-dynamics method for efficient sampling in the temperature space.

    PubMed

    Chen, Changjun; Xiao, Yi; Huang, Yanzhao

    2015-05-01

    Replica-exchange molecular dynamics (REMD) is a popular sampling method in the molecular simulation. By frequently exchanging the replicas at different temperatures, the molecule can jump out of the minima and sample efficiently in the conformational space. Although REMD has been shown to be practical in a lot of applications, it does have a critical limitation. All the replicas at all the temperatures must be simulated for a period between the replica-exchange steps. This may be problematic for the reaction with high free energy barriers. In that case, too many replicas are required in the simulation. To reduce the calculation quantity and improve its performance, in this paper we propose a modified REMD method. During the simulation, each replica at each temperature can stay in either the active or inactive state and only switch between the states at the exchange step. In the active state, the replica moves freely in the canonical ensemble by the normal molecular dynamics, and in the inactive state, the replica is frozen temporarily until the next exchange step. The number of the replicas in the active states (active replicas) depends on the number of CPUs in the computer. Using the additional inactive replicas, one can perform an REMD simulation in a wider temperature space. The practical applications show that the modified REMD method is reliable. With the same number of active replicas, this REMD method can produce a more reasonable free energy surface around the free energy minima than the standard REMD method. PMID:26066200

  2. Predictive Array Design. A method for sampling combinatorial chemistry library space.

    PubMed

    Lipkin, M J; Rose, V S; Wood, J

    2002-01-01

    A method, Predictive Array Design, is presented for sampling combinatorial chemistry space and selecting a subarray for synthesis based on the experimental design method of Latin Squares. The method is appropriate for libraries with three sites of variation. Libraries with four sites of variation can be designed using the Graeco-Latin Square. Simulated annealing is used to optimise the physicochemical property profile of the sub-array. The sub-array can be used to make predictions of the activity of compounds in the all combinations array if we assume each monomer has a relatively constant contribution to activity and that the activity of a compound is composed of the sum of the activities of its constitutive monomers.

  3. Comparison of different serum sample extraction methods and their suitability for mass spectrometry analysis

    PubMed Central

    Alshammari, Thamir M.; Al-Hassan, Ahmed Ali; Hadda, Taibi B.; Aljofan, Mohamad

    2015-01-01

    Mass spectrometry has been widely used, particularly in pharmacokinetic investigations and for therapeutic drug monitoring purposes. Like any other analytical method some difficulties exist in employing mass spectrometry, mainly when it is used to test biological samples, such as to detect drug candidates in mammalian serum, which is rich in proteins, lipids and other contents that may interfere with the investigational drug. The complexity of the serum proteome presents challenges for efficient sample preparation and adequate sensitivity for mass spectrometry analysis of drugs. Enrichment procedures prior to the drug analysis are often needed and as a result, the study of serum or plasma components usually demands either methods of purification or depletion of one or more. Selection of the best combination of sample introduction method is a crucial determinant of the sensitivity and accuracy of mass spectrometry. The aim of this study was to determine the highest serum protein precipitation activity of five commonly used sample preparation methods and test their suitability for mass spectrometry. We spiked three small molecules into rabbit serum and applied different protein precipitation methods to determine their precipitation activity and applicability as a mass spectrometry introductory tool. PMID:26702265

  4. Sampling and Decontamination Method for Culture of Nontuberculous Mycobacteria in Respiratory Samples of Cystic Fibrosis Patients

    PubMed Central

    De Geyter, Deborah; De Schutter, Iris; Mouton, Christine; Wellemans, Isabelle; Hanssens, Laurence; Schelstraete, Petra; Malfroot, Anne; Pierard, Denis

    2013-01-01

    We confirmed that chlorhexidine decontamination yielded more nontuberculous mycobacteria than did the N-acetyl-l-cysteine-NaOH-oxalic acid procedure from respiratory samples of cystic fibrosis patients on solid cultures. However, this improved recovery is mostly balanced if the latter is combined with liquid culture. Furthermore, none of the 145 cough swabs, used to sample young children, cultured positive, suggesting that swabs are low-quality samples. PMID:24048532

  5. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    PubMed

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  6. Photoacoustic spectroscopy sample array vessels and photoacoustic spectroscopy methods for using the same

    DOEpatents

    Amonette, James E.; Autrey, S. Thomas; Foster-Mills, Nancy S.

    2006-02-14

    Methods and apparatus for simultaneous or sequential, rapid analysis of multiple samples by photoacoustic spectroscopy are disclosed. Particularly, a photoacoustic spectroscopy sample array vessel including a vessel body having multiple sample cells connected thereto is disclosed. At least one acoustic detector is acoustically positioned near the sample cells. Methods for analyzing the multiple samples in the sample array vessels using photoacoustic spectroscopy are provided.

  7. A rapid bioassay method for the determination of 90Sr in human urine sample.

    PubMed

    Sadi, Baki B; Li, Chunsheng; Jodayree, Sara; Lai, Edward P C; Kochermin, Vera; Kramer, Gary H

    2010-06-01

    A rapid bioassay method has been developed for the determination of (90)Sr in human urine samples. The method is based on on-cartridge decolourisation of urine sample, separation of (90)Y from (90)Sr on an anion exchange resin column and by determination of (90)Sr using a liquid scintillation analyser (LSA). Separation of (90)Y from (90)Sr was achieved through selective complexation of yttrium with phosphate and subsequent retention of the anionic yttrium phosphate species on anion exchange resin. A total recovery of 97 +/- 2 % was obtained for strontium with three washes. The minimum detectable activity for the method was 0.2 Bq or 40 Bq l(-1). Measurement accuracy (relative bias, B(r)) and repeatability (relative precision, S(B)) of the method for the determination of (90)Sr were found to be -1 and 4.7 %, respectively. Excellent linearity (r(2) > 0.999) was established over an activity range from 3.25 x 10(2) to 3.25 x 10(4) Bq l(-1). The method was also found to be very robust (S(B) < 5 %) against the matrix effect from different urine samples. Performance of the rapid bioassay method for sensitivity, accuracy and repeatability evaluated against the performance criteria for radiobioassay (ANSI N13.30) was found to be in compliant. Considering the simplicity, excellent analytical figures of merit, fast sample turnaround time (<1 h) and cost efficiency (<30 USD per sample) of the developed method, it is very promising as a rapid bioassay method for supporting the medical response to an emergency where internal contamination of (90)Sr is involved.

  8. Activated G Protein Gαs Samples Multiple Endomembrane Compartments.

    PubMed

    Martin, Brent R; Lambert, Nevin A

    2016-09-23

    Heterotrimeric G proteins are localized to the plasma membrane where they transduce extracellular signals to intracellular effectors. G proteins also act at intracellular locations, and can translocate between cellular compartments. For example, Gαs can leave the plasma membrane and move to the cell interior after activation. However, the mechanism of Gαs translocation and its intracellular destination are not known. Here we use bioluminescence resonance energy transfer (BRET) to show that after activation, Gαs rapidly associates with the endoplasmic reticulum, mitochondria, and endosomes, consistent with indiscriminate sampling of intracellular membranes from the cytosol rather than transport via a specific vesicular pathway. The primary source of Gαs for endosomal compartments is constitutive endocytosis rather than activity-dependent internalization. Recycling of Gαs to the plasma membrane is complete 25 min after stimulation is discontinued. We also show that an acylation-deacylation cycle is important for the steady-state localization of Gαs at the plasma membrane, but our results do not support a role for deacylation in activity-dependent Gαs internalization. PMID:27528603

  9. Rapid-Viability PCR Method for Detection of Live, Virulent Bacillus anthracis in Environmental Samples

    PubMed Central

    Létant, Sonia E.; Murphy, Gloria A.; Alfaro, Teneile M.; Avila, Julie R.; Kane, Staci R.; Raber, Ellen; Bunt, Thomas M.; Shah, Sanjiv R.

    2011-01-01

    In the event of a biothreat agent release, hundreds of samples would need to be rapidly processed to characterize the extent of contamination and determine the efficacy of remediation activities. Current biological agent identification and viability determination methods are both labor- and time-intensive such that turnaround time for confirmed results is typically several days. In order to alleviate this issue, automated, high-throughput sample processing methods were developed in which real-time PCR analysis is conducted on samples before and after incubation. The method, referred to as rapid-viability (RV)-PCR, uses the change in cycle threshold after incubation to detect the presence of live organisms. In this article, we report a novel RV-PCR method for detection of live, virulent Bacillus anthracis, in which the incubation time was reduced from 14 h to 9 h, bringing the total turnaround time for results below 15 h. The method incorporates a magnetic bead-based DNA extraction and purification step prior to PCR analysis, as well as specific real-time PCR assays for the B. anthracis chromosome and pXO1 and pXO2 plasmids. A single laboratory verification of the optimized method applied to the detection of virulent B. anthracis in environmental samples was conducted and showed a detection level of 10 to 99 CFU/sample with both manual and automated RV-PCR methods in the presence of various challenges. Experiments exploring the relationship between the incubation time and the limit of detection suggest that the method could be further shortened by an additional 2 to 3 h for relatively clean samples. PMID:21764960

  10. Human breath analysis: methods for sample collection and reduction of localized background effects.

    PubMed

    Martin, Audrey N; Farquar, George R; Jones, A Daniel; Frank, Matthias

    2010-01-01

    Solid-phase microextraction (SPME) was applied, in conjunction with gas chromatography-mass spectrometry, to the analysis of volatile organic compounds (VOCs) in human breath samples without requiring exhaled breath condensate collection. A new procedure, exhaled breath vapor (EBV) collection, involving the active sampling and preconcentration of a breath sample with a SPME fiber fitted inside a modified commercial breath-collection device, the RTube, is described. Immediately after sample collection, compounds are desorbed from the SPME fiber at 250 degrees C in the GC-MS injector. Experiments were performed using EBV collected at -80 degrees C and at room temperature, and the results compared to the traditional method of collecting exhaled breath condensate at -80 degrees C followed by passive SPME sampling of the collected condensate. Methods are compared in terms of portability, ease-of-use, speed of analysis, and detection limits. The need for a clean air supply for the study subjects is demonstrated using several localized sources of VOC contaminants including nail polish, lemonade, and gasoline. Various simple methods to supply clean inhaled air to a subject are presented. Chemical exposures are used to demonstrate the importance of providing cleaned air (organic vapor respirator) or an external air source (tubing stretched to a separate room). These techniques allow for facile data interpretation by minimizing background contaminants. It is demonstrated herein that this active SPME breath-sampling device provides advantages in the forms of faster sample collection and data analysis, apparatus portability and avoidance of power or cooling requirements, and performance for sample collection in a contaminated environment. PMID:19844696

  11. A comparison of four gravimetric fine particle sampling methods.

    PubMed

    Yanosky, J D; MacIntosh, D L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).

  12. Antimicrobial activity of two propolis samples against human Campylobacter jejuni.

    PubMed

    Campana, Raffaella; Patrone, Vania; Franzini, Ingrid Tarsilla Maria; Diamantini, Giuseppe; Vittoria, Emanuela; Baffone, Wally

    2009-10-01

    The aim of this study was to analyze the antimicrobial activity of two ethanolic extracts of propolis (EEPs) and selected flavonoids against 16 Campylobacter jejuni clinical isolates and several Gram-positive and Gram-negative human pathogens. The antimicrobial activity of EEPs and flavonoids was evaluated by the agar well diffusion method. The EEPs inhibited the growth of C. jejuni, Enterobacter faecalis, and Staphylococcus aureus. The most active flavonoid was galangin, with the highest percentage of sensitivity among C. jejuni strains (68.8%); lower percentages of sensitivity were observed for quercetin (50%). The minimal inhibitory concentrations (MICs) of EEPs and flavonoids for C. jejuni isolates were determined by the agar dilution method. EEPs showed MIC values of 0.3125-0.156 mg/mL for all C. jejuni strains; galangin and quercetin gave MICs ranging from 0.250 to 0.125 mg/mL. Thus propolis preparations could be used as support to traditional therapy for Campylobacter infection, especially when the antibiotic agents show no activity against this microorganism.

  13. [Current methods for preparing samples on working with hematology analyzers].

    PubMed

    Tsyganova, A V; Pogorelov, V M; Naumova, I N; Kozinets, G I; Antonov, V S

    2011-03-01

    The paper raises a problem of preparing samples in hematology. It considers whether the preanalytical stage is of importance in hematological studies. The use of disposal vacuum blood collection systems is shown to solve the problem in the standardization of a blood sampling procedure. The benefits of the use of close tube hematology analyzers are also considered. PMID:21584966

  14. Acoustically levitated droplets: a contactless sampling method for fluorescence studies.

    PubMed

    Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich

    2008-01-01

    Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence. PMID:18596335

  15. Accuracy of activPAL Self-Attachment Methods

    ERIC Educational Resources Information Center

    Kringen, Nina L.; Healy, Genevieve N.; Winkler, Elisabeth A. H.; Clark, Bronwyn K.

    2016-01-01

    This study examined the accuracy of self-attachment of the activPAL activity monitor. A convenience sample of 50 participants self-attached the monitor after being presented with written material only (WMO) and then written and video (WV) instructions; and completed a questionnaire regarding the acceptability of the instructional methods.…

  16. Transformation-cost time-series method for analyzing irregularly sampled data.

    PubMed

    Ozken, Ibrahim; Eroglu, Deniz; Stemler, Thomas; Marwan, Norbert; Bagci, G Baris; Kurths, Jürgen

    2015-06-01

    Irregular sampling of data sets is one of the challenges often encountered in time-series analysis, since traditional methods cannot be applied and the frequently used interpolation approach can corrupt the data and bias the subsequence analysis. Here we present the TrAnsformation-Cost Time-Series (TACTS) method, which allows us to analyze irregularly sampled data sets without degenerating the quality of the data set. Instead of using interpolation we consider time-series segments and determine how close they are to each other by determining the cost needed to transform one segment into the following one. Using a limited set of operations-with associated costs-to transform the time series segments, we determine a new time series, that is our transformation-cost time series. This cost time series is regularly sampled and can be analyzed using standard methods. While our main interest is the analysis of paleoclimate data, we develop our method using numerical examples like the logistic map and the Rössler oscillator. The numerical data allows us to test the stability of our method against noise and for different irregular samplings. In addition we provide guidance on how to choose the associated costs based on the time series at hand. The usefulness of the TACTS method is demonstrated using speleothem data from the Secret Cave in Borneo that is a good proxy for paleoclimatic variability in the monsoon activity around the maritime continent.

  17. Alternative methods for determining the electrical conductivity of core samples.

    PubMed

    Lytle, R J; Duba, A G; Willows, J L

    1979-05-01

    Electrode configurations are described that can be used in measuring the electrical conductivity of a core sample and that do not require access to the core end faces. The use of these configurations eliminates the need for machining the core ends for placement of end electrodes. This is because the conductivity in the cases described is relatively insensitive to the length of the sample. We validated the measurement technique by comparing mathematical models with actual measurements that were made perpendicular and paralled to the core axis of granite samples.

  18. Associations between Physical Activity and Health-Related Factors in a National Sample of College Students

    ERIC Educational Resources Information Center

    Dinger, Mary K.; Brittain, Danielle R.; Hutchinson, Susan R.

    2014-01-01

    Objective: To examine associations between meeting the current moderate to vigorous physical activity (MVPA) recommendation and health-related factors in a national sample of college students. Participants: Participants (N = 67,861) completed the National College Health Assessment II during the Fall 2008/Spring 2009 academic year. Methods:…

  19. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings. PMID:27569522

  20. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  1. Active sampling and decision making in Drosophila chemotaxis

    PubMed Central

    Gomez-Marin, Alex; Stephens, Greg J.; Louis, Matthieu

    2011-01-01

    The ability to respond to chemical stimuli is fundamental to the survival of motile organisms, but the strategies underlying odour tracking remain poorly understood. Here we show that chemotaxis in Drosophila melanogaster larvae is an active sampling process analogous to sniffing in vertebrates. Combining computer-vision algorithms with reconstructed olfactory environments, we establish that larvae orient in odour gradients through a sequential organization of stereotypical behaviours, including runs, stops, lateral head casts and directed turns. Negative gradients, integrated during runs, control the timing of turns. Positive gradients detected through high-amplitude head casts determine the direction of individual turns. By genetically manipulating the peripheral olfactory circuit, we examine how orientation adapts to losses and gains of function in olfactory input. Our findings suggest that larval chemotaxis represents an intermediate navigation strategy between the biased random walks of Escherichia Coli and the stereo-olfaction observed in rats and humans. PMID:21863008

  2. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 2, Sample preparation methods

    SciTech Connect

    Not Available

    1993-08-01

    This volume contains the interim change notice for sample preparation methods. Covered are: acid digestion for metals analysis, fusion of Hanford tank waste solids, water leach of sludges/soils/other solids, extraction procedure toxicity (simulate leach in landfill), sample preparation for gamma spectroscopy, acid digestion for radiochemical analysis, leach preparation of solids for free cyanide analysis, aqueous leach of solids for anion analysis, microwave digestion of glasses and slurries for ICP/MS, toxicity characteristic leaching extraction for inorganics, leach/dissolution of activated metal for radiochemical analysis, extraction of single-shell tank (SST) samples for semi-VOC analysis, preparation and cleanup of hydrocarbon- containing samples for VOC and semi-VOC analysis, receiving of waste tank samples in onsite transfer cask, receipt and inspection of SST samples, receipt and extrusion of core samples at 325A shielded facility, cleaning and shipping of waste tank samplers, homogenization of solutions/slurries/sludges, and test sample preparation for bioassay quality control program.

  3. Comparison of sample preparation methods for the recovery of foodborne pathogens from fresh produce.

    PubMed

    Kim, Se-Ri; Yoon, Yohan; Kim, Won-Il; Park, Kyeong-Hun; Yun, Hye-Jeong; Chung, Duck Hwa; Yun, Jong Chul; Ryu, Kyoung Yul

    2012-07-01

    Sample preparation methods (pummeling, pulsifying, sonication, and shaking by hand) were compared for achieving maximum recovery of foodborne pathogens from iceberg lettuce, perilla leaves, cucumber, green pepper, and cherry tomato. Antimicrobial and dehydration effects also were examined to investigate causes of poor recovery of pathogens. Each produce type was inoculated with Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Staphylococcus aureus, and Bacillus cereus at 6.0 log CFU/cm(2), and samples were prepared using the four methods. Bacterial populations recovered from the five types of produce were significantly different (P < 0.05) according to sample preparation methods and produce type. The bacterial populations recovered from pummeled and pulsified samples were higher (P < 0.05) than those recovered from sonicated and hand-shaken samples, except for cherry tomato. The number of bacteria recovered from produce was reduced (P < 0.05) from that of the inoculum by 0.16 to 2.69 log CFU/cm(2). Although extracts of iceberg lettuce, perilla leaves, cucumber, and green pepper had no antimicrobial activity, the populations of E. coli O157:H7, Salmonella Typhimurium, B. cereus, and L. monocytogenes in cherry tomato extract were slightly reduced after these treatments (P < 0.05). The pathogen populations on perilla leaves and cherry tomatoes decreased by >2 log CFU/cm(2) after exposure to 40% relative humidity for 1 h. No reduction was observed when the five pathogens were exposed to 90% relative humidity. These data suggest that pummeling and pulsifying are optimal sample preparation methods for detection of microorganisms. Acidic produce such as cherry tomato should be treated with a method that does not cause sample breakdown so that acid stress on the bacteria can be minimized. Dehydration stress also affects recovery of pathogens from produce. PMID:22980003

  4. Field sampling method for quantifying odorants in humid environments.

    PubMed

    Trabue, Steven L; Scoggin, Kenwood D; Li, Hong; Burns, Robert; Xin, Hongwei

    2008-05-15

    Most air quality studies in agricultural environments use thermal desorption analysis for quantifying semivolatile organic compounds (SVOCs) associated with odor. The objective of this study was to develop a robust sampling technique for measuring SVOCs in humid environments. Test atmospheres were generated at ambient temperatures (23 +/- 1.5 degrees C) and 25, 50, and 80% relative humidity (RH). Sorbent material used included Tenax, graphitized carbon, and carbon molecular sieve (CMS). Sorbent tubes were challenged with 2, 4, 8, 12, and 24 L of air at various RHs. Sorbent tubes with CMS material performed poorly at both 50 and 80% RH dueto excessive sorption of water. Heating of CMS tubes during sampling or dry-purging of CMS tubes post sampling effectively reduced water sorption with heating of tubes being preferred due to the higher recovery and reproducibility. Tenaxtubes had breakthrough of the more volatile compounds and tended to form artifacts with increasing volumes of air sampled. Graphitized carbon sorbent tubes containing Carbopack X and Carbopack C performed best with quantitative recovery of all compounds at all RHs and sampling volumes tested. The graphitized carbon tubes were taken to the field for further testing. Field samples taken from inside swine feeding operations showed that butanoic acid, 4-methylphenol, 4-ethylphenol, indole, and 3-methylindole were the compounds detected most often above their odor threshold values. Field samples taken from a poultry facility demonstrated that butanoic acid, 3-methylbutanoic acid, and 4-methylphenol were the compounds above their odor threshold values detected most often, relative humidity, CAFO, VOC, SVOC, thermal desorption, swine, poultry, air quality, odor. PMID:18546717

  5. Photoacoustic spectroscopy sample array vessel and photoacoustic spectroscopy method for using the same

    DOEpatents

    Amonette, James E.; Autrey, S. Thomas; Foster-Mills, Nancy S.; Green, David

    2005-03-29

    Methods and apparatus for analysis of multiple samples by photoacoustic spectroscopy are disclosed. Particularly, a photoacoustic spectroscopy sample array vessel including a vessel body having multiple sample cells connected thereto is disclosed. At least one acoustic detector is acoustically coupled with the vessel body. Methods for analyzing the multiple samples in the sample array vessels using photoacoustic spectroscopy are provided.

  6. Fast sample preparation for analysis of tablets and capsules: the ball-mill extraction method.

    PubMed

    Kok, S J; Debets, A J

    2001-11-01

    A new ball-mill extraction method for solid dosage forms was developed. It was used for tablets, and compared with a conventional (powdering and sonication) method applied in pharmaceutical analysis of solid dosage forms. The ball-mill sample preparation procedure is both quantitative and fast. No powdering, weighing and sonication steps are needed in the sample preparation. The complete procedure takes 2 min (milling and extraction) and 5 min (centrifugation), respectively, much less than the conventional method in which sample preparation takes approximately 45-90 min. The samples are centrifuged in the mill vial, which saves time and avoids evaporation of solvent. Stainless steel extraction vials with different diameters were fabricated to enable the use of various extraction volumes. The extraction recovery was tested using various types of tablets (small, large and extended release tablets) with active compounds at low and higher concentrations, recoveries were comparable with the conventional method. The relative small investment and simplicity of the method makes it excellently suited for use in various pharmaceutical (development and quality assurance) laboratories. PMID:11516911

  7. Activation energy for a model ferrous-ferric half reaction from transition path sampling

    NASA Astrophysics Data System (ADS)

    Drechsel-Grau, Christof; Sprik, Michiel

    2012-01-01

    Activation parameters for the model oxidation half reaction of the classical aqueous ferrous ion are compared for different molecular simulation techniques. In particular, activation free energies are obtained from umbrella integration and Marcus theory based thermodynamic integration, which rely on the diabatic gap as the reaction coordinate. The latter method also assumes linear response, and both methods obtain the activation entropy and the activation energy from the temperature dependence of the activation free energy. In contrast, transition path sampling does not require knowledge of the reaction coordinate and directly yields the activation energy [C. Dellago and P. G. Bolhuis, Mol. Simul. 30, 795 (2004), 10.1080/08927020412331294869]. Benchmark activation energies from transition path sampling agree within statistical uncertainty with activation energies obtained from standard techniques requiring knowledge of the reaction coordinate. In addition, it is found that the activation energy for this model system is significantly smaller than the activation free energy for the Marcus model, approximately half the value, implying an equally large entropy contribution.

  8. Method for preconcentrating a sample for subsequent analysis

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for analysis of trace concentration of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  9. Analytical instrument with apparatus and method for sample concentrating

    DOEpatents

    Zaromb, S.

    1986-08-04

    A system for analysis of trace concentrations of contaminants in air includes a portable liquid chromatograph and a preconcentrator for the contaminants to be analyzed. The preconcentrator includes a sample bag having an inlet valve and an outlet valve for collecting an air sample. When the sample is collected the sample bag is connected in series with a sorbing apparatus in a recirculation loop. The sorbing apparatus has an inner gas-permeable container containing a sorbent material and an outer gas-impermeable container. The sample is circulated through the outer container and around the inner container for trapping and preconcentrating the contaminants in the sorbent material. The sorbent material may be a liquid having the same composition as the mobile phase of the chromatograph for direct injection thereinto. Alternatively, the sorbent material may be a porous, solid body, to which mobile phase liquid is added after preconcentration of the contaminants for dissolving the contaminants, the liquid solution then being withdrawn for injection into the chromatograph.

  10. Statistical Methods and Tools for Hanford Staged Feed Tank Sampling

    SciTech Connect

    Fountain, Matthew S.; Brigantic, Robert T.; Peterson, Reid A.

    2013-10-01

    This report summarizes work conducted by Pacific Northwest National Laboratory to technically evaluate the current approach to staged feed sampling of high-level waste (HLW) sludge to meet waste acceptance criteria (WAC) for transfer from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP). The current sampling and analysis approach is detailed in the document titled Initial Data Quality Objectives for WTP Feed Acceptance Criteria, 24590-WTP-RPT-MGT-11-014, Revision 0 (Arakali et al. 2011). The goal of this current work is to evaluate and provide recommendations to support a defensible, technical and statistical basis for the staged feed sampling approach that meets WAC data quality objectives (DQOs).

  11. Sample Selection in Randomized Experiments: A New Method Using Propensity Score Stratified Sampling

    ERIC Educational Resources Information Center

    Tipton, Elizabeth; Hedges, Larry; Vaden-Kiernan, Michael; Borman, Geoffrey; Sullivan, Kate; Caverly, Sarah

    2014-01-01

    Randomized experiments are often seen as the "gold standard" for causal research. Despite the fact that experiments use random assignment to treatment conditions, units are seldom selected into the experiment using probability sampling. Very little research on experimental design has focused on how to make generalizations to well-defined…

  12. Apparatus and method for centrifugation and robotic manipulation of samples

    NASA Technical Reports Server (NTRS)

    Vellinger, John C. (Inventor); Ormsby, Rachel A. (Inventor); Kennedy, David J. (Inventor); Thomas, Nathan A. (Inventor); Shulthise, Leo A. (Inventor); Kurk, Michael A. (Inventor); Metz, George W. (Inventor)

    2007-01-01

    A device for centrifugation and robotic manipulation of specimen samples, including incubating eggs, and uses thereof are provided. The device may advantageously be used for the incubation of avian, reptilian or any type of vertebrate eggs. The apparatus comprises a mechanism for holding samples individually, rotating them individually, rotating them on a centrifuge collectively, injecting them individually with a fixative or other chemical reagent, and maintaining them at controlled temperature, relative humidity and atmospheric composition. The device is applicable to experiments involving entities other than eggs, such as invertebrate specimens, plants, microorganisms and molecular systems.

  13. Rapid and reliable determination of the halogenating peroxidase activity in blood samples.

    PubMed

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2014-12-15

    By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases.

  14. SAMSAN- MODERN NUMERICAL METHODS FOR CLASSICAL SAMPLED SYSTEM ANALYSIS

    NASA Technical Reports Server (NTRS)

    Frisch, H. P.

    1994-01-01

    SAMSAN was developed to aid the control system analyst by providing a self consistent set of computer algorithms that support large order control system design and evaluation studies, with an emphasis placed on sampled system analysis. Control system analysts have access to a vast array of published algorithms to solve an equally large spectrum of controls related computational problems. The analyst usually spends considerable time and effort bringing these published algorithms to an integrated operational status and often finds them less general than desired. SAMSAN reduces the burden on the analyst by providing a set of algorithms that have been well tested and documented, and that can be readily integrated for solving control system problems. Algorithm selection for SAMSAN has been biased toward numerical accuracy for large order systems with computational speed and portability being considered important but not paramount. In addition to containing relevant subroutines from EISPAK for eigen-analysis and from LINPAK for the solution of linear systems and related problems, SAMSAN contains the following not so generally available capabilities: 1) Reduction of a real non-symmetric matrix to block diagonal form via a real similarity transformation matrix which is well conditioned with respect to inversion, 2) Solution of the generalized eigenvalue problem with balancing and grading, 3) Computation of all zeros of the determinant of a matrix of polynomials, 4) Matrix exponentiation and the evaluation of integrals involving the matrix exponential, with option to first block diagonalize, 5) Root locus and frequency response for single variable transfer functions in the S, Z, and W domains, 6) Several methods of computing zeros for linear systems, and 7) The ability to generate documentation "on demand". All matrix operations in the SAMSAN algorithms assume non-symmetric matrices with real double precision elements. There is no fixed size limit on any matrix in any

  15. Improved sample management in the cylindrical-tube microelectrophoresis method

    NASA Technical Reports Server (NTRS)

    Smolka, A. J. K.

    1980-01-01

    A modification to an analytical microelectrophoresis system is described that improves the manipulation of the sample particles and fluid. The apparatus modification and improved operational procedure should yield more accurate measurements of particle mobilities and permit less skilled operators to use the apparatus.

  16. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... protocols listed below, for sampling waste with properties similar to the indicated materials, will be considered by the Agency to be representative of the waste. Extremely viscous liquid—ASTM Standard D140-70...-like material—ASTM Standard D1452-65 Fly Ash-like material—ASTM Standard D2234-76 Containerized...

  17. 40 CFR Appendix I to Part 261 - Representative Sampling Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protocols listed below, for sampling waste with properties similar to the indicated materials, will be considered by the Agency to be representative of the waste. Extremely viscous liquid—ASTM Standard D140-70...-like material—ASTM Standard D1452-65 Fly Ash-like material—ASTM Standard D2234-76 Containerized...

  18. INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

    SciTech Connect

    JG DOUGLAS; HK MEZNARICH, PHD; JR OLSEN; GA ROSS PHD; M STAUFFER

    2009-02-13

    Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively

  19. Exploring biomolecular dynamics and interactions using advanced sampling methods

    NASA Astrophysics Data System (ADS)

    Luitz, Manuel; Bomblies, Rainer; Ostermeir, Katja; Zacharias, Martin

    2015-08-01

    Molecular dynamics (MD) and Monte Carlo (MC) simulations have emerged as a valuable tool to investigate statistical mechanics and kinetics of biomolecules and synthetic soft matter materials. However, major limitations for routine applications are due to the accuracy of the molecular mechanics force field and due to the maximum simulation time that can be achieved in current simulations studies. For improving the sampling a number of advanced sampling approaches have been designed in recent years. In particular, variants of the parallel tempering replica-exchange methodology are widely used in many simulation studies. Recent methodological advancements and a discussion of specific aims and advantages are given. This includes improved free energy simulation approaches and conformational search applications.

  20. Comparison of methods for sampling plant bugs on cotton in South Texas (2010)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A total of 26 cotton fields were sampled by experienced and inexperienced samplers at 3 growth stages using 5 methods to compare the most efficient and accurate method for sampling plant bugs in cotton. Each of the 5 methods had its own distinct advantages and disadvantages as a sampling method (too...

  1. A new method of snowmelt sampling for water stable isotopes

    USGS Publications Warehouse

    Penna, D.; Ahmad, M.; Birks, S. J.; Bouchaou, L.; Brencic, M.; Butt, S.; Holko, L.; Jeelani, G.; Martinez, D. E.; Melikadze, G.; Shanley, J.B.; Sokratov, S. A.; Stadnyk, T.; Sugimoto, A.; Vreca, P.

    2014-01-01

    We modified a passive capillary sampler (PCS) to collect snowmelt water for isotopic analysis. Past applications of PCSs have been to sample soil water, but the novel aspect of this study was the placement of the PCSs at the ground-snowpack interface to collect snowmelt. We deployed arrays of PCSs at 11 sites in ten partner countries on five continents representing a range of climate and snow cover worldwide. The PCS reliably collected snowmelt at all sites and caused negligible evaporative fractionation effects in the samples. PCS is low-cost, easy to install, and collects a representative integrated snowmelt sample throughout the melt season or at the melt event scale. Unlike snow cores, the PCS collects the water that would actually infiltrate the soil; thus, its isotopic composition is appropriate to use for tracing snowmelt water through the hydrologic cycle. The purpose of this Briefing is to show the potential advantages of PCSs and recommend guidelines for constructing and installing them based on our preliminary results from two snowmelt seasons.

  2. Cellulase activity screening using pure carboxymethylcellulose: application to soluble cellulolytic samples and to plant tissue prints.

    PubMed

    Johnsen, Hanne R; Krause, Kirsten

    2014-01-01

    Reliable, rapid and inexpensive detection of cellulolytic enzymes that can be used for a wide variety of biological and environmental samples are currently in high demand. Here, a new cellulase detection protocol is described that circumvents problems observed with popular agar-based methods by exploiting the ability of carboxymethylcellulose (CMC) to form gel-like surfaces on its own. These pure CMC-layers are sensitive to cellulolytic degradation and stainable by Gram's iodine without showing unwelcome reactions with other enzymes. The staining intensity negatively correlates with the enzyme activity and can be used for quantification. Cellulase activities are not obstructed by high sugar contents (e.g., in plant material) which limit the applicability of other quantification methods, making our new method particularly attractive for screening of plant extracts. A useful variant of this new method is its applicability to plant tissue prints for spatial mapping of the cellulolytic activity in a zymogram-like fashion. PMID:24413752

  3. Capture-recapture and removal methods for sampling closed populations

    USGS Publications Warehouse

    White, Gary C.; Anderson, David R.; Burnham, Kenneth P.; Otis, David L.

    1982-01-01

    The problem of estimating animal abundance is common in wildlife management and environmental impact asessment. Capture-recapture and removal methods are often used to estimate population size. Statistical Inference From Capture Data On Closed Animal Populations, a monograph by Otis et al. (1978), provides a comprehensive synthesis of much of the wildlife and statistical literature on the methods, as well as some extensions of the general theory. In our primer, we focus on capture-recapture and removal methods for trapping studies in which a population is assumed to be closed and do not treat open-population models, such as the Jolly-Seber model, or catch-effort methods in any detail. The primer, written for students interested in population estimation, is intended for use with the more theoretical monograph.

  4. A method for reducing sampling jitter in digital control systems

    NASA Technical Reports Server (NTRS)

    Anderson, T. O.; HURBD W. J.; Hurd, W. J.

    1969-01-01

    Digital phase lock loop system is designed by smoothing the proportional control with a low pass filter. This method does not significantly affect the loop dynamics when the smoothing filter bandwidth is wide compared to loop bandwidth.

  5. Estimation of avidin activity by two methods.

    PubMed

    Borza, B; Marcheş, F; Repanovici, R; Burducea, O; Popa, L M

    1991-01-01

    The biological activity of avidin was estimated by two different methods. The spectrophotometric method used the avidin titration with biotin in the presence of 4 hydroxiazobenzen-2'carboxilic acid as indicator. In the radioisotopic determination the titration with tritiated biotin was accomplished. Both methods led to the same results, but the spectrophotometric one is less avidin expensive and more rapid, being more convenient.

  6. Review of the Subliminal Psychodynamic Activation Method.

    ERIC Educational Resources Information Center

    Hoffman, Janice Sue

    The subliminal psychodynamic activation method (SPA), used in testing psychoanalytic propositions, has been subject to recent criticisms regarding methodological weaknesses. A review of the literature relating to this method can be helpful in determining the validity of these criticisms and the potential usefulness of the SPA method in testing…

  7. Detecting spatial structures in throughfall data: the effect of extent, sample size, sampling design, and variogram estimation method

    NASA Astrophysics Data System (ADS)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-04-01

    In the last three decades, an increasing number of studies analyzed spatial patterns in throughfall to investigate the consequences of rainfall redistribution for biogeochemical and hydrological processes in forests. In the majority of cases, variograms were used to characterize the spatial properties of the throughfall data. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and an appropriate layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation methods on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with heavy outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling), and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least

  8. Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method

    NASA Astrophysics Data System (ADS)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-09-01

    In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous

  9. Analytical methods for the determination of personal care products in human samples: an overview.

    PubMed

    Jiménez-Díaz, I; Zafra-Gómez, A; Ballesteros, O; Navalón, A

    2014-11-01

    Personal care products (PCPs) are organic chemicals widely used in everyday human life. Nowadays, preservatives, UV-filters, antimicrobials and musk fragrances are widely used PCPs. Different studies have shown that some of these compounds can cause adverse health effects, such as genotoxicity, which could even lead to mutagenic or carcinogenic effects, or estrogenicity because of their endocrine disruption activity. Due to the absence of official monitoring protocols, there is an increasing demand of analytical methods that allow the determination of those compounds in human samples in order to obtain more information regarding their behavior and fate in the human body. The complexity of the biological matrices and the low concentration levels of these compounds make necessary the use of advanced sample treatment procedures that afford both, sample clean-up, to remove potentially interfering matrix components, as well as the concentration of analytes. In the present work, a review of the more recent analytical methods published in the scientific literature for the determination of PCPs in human fluids and tissue samples, is presented. The work focused on sample preparation and the analytical techniques employed.

  10. Mass spectrometric detection of ricin and its activity in food and clinical samples.

    PubMed

    Kalb, Suzanne R; Barr, John R

    2009-03-15

    Ricin is a potent toxin capable of inhibiting protein synthesis and causing death or respiratory failure. Because of its high availability and lethality, ricin is considered a likely agent for bioterrorism. Rapidly determining contamination of food product with ricin and human exposure to ricin is therefore an important public health goal. In this work, we report the development of a method that detects ricin and its activity in food or clinical samples. This method involves immunocapture of the toxin, an examination of the activity of the ricin protein upon a DNA substrate that mimics the toxin's natural RNA target, and analysis of tryptic fragments of the toxin itself. It is the combination of these three techniques, all performed on the same sample, which allows for a sensitive and selective analysis of ricin isolated from a food or clinical sample. This measurement includes a measure of the toxin's activity. The utility of this method was demonstrated on ricin spiked into food and clinical samples consisting of milk, apple juice, serum, and saliva. PMID:19228034

  11. Ant colony optimization as a method for strategic genotype sampling.

    PubMed

    Spangler, M L; Robbins, K R; Bertrand, J K; Macneil, M; Rekaya, R

    2009-06-01

    A simulation study was carried out to develop an alternative method of selecting animals to be genotyped. Simulated pedigrees included 5000 animals, each assigned genotypes for a bi-allelic single nucleotide polymorphism (SNP) based on assumed allelic frequencies of 0.7/0.3 and 0.5/0.5. In addition to simulated pedigrees, two beef cattle pedigrees, one from field data and the other from a research population, were used to test selected methods using simulated genotypes. The proposed method of ant colony optimization (ACO) was evaluated based on the number of alleles correctly assigned to ungenotyped animals (AK(P)), the probability of assigning true alleles (AK(G)) and the probability of correctly assigning genotypes (APTG). The proposed animal selection method of ant colony optimization was compared to selection using the diagonal elements of the inverse of the relationship matrix (A(-1)). Comparisons of these two methods showed that ACO yielded an increase in AK(P) ranging from 4.98% to 5.16% and an increase in APTG from 1.6% to 1.8% using simulated pedigrees. Gains in field data and research pedigrees were slightly lower. These results suggest that ACO can provide a better genotyping strategy, when compared to A(-1), with different pedigree sizes and structures. PMID:19220227

  12. A Study of Tapered Beard Sampling Method as Used in HVI

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Beard method is used for sampling cotton fibers to generate fibrograms from which length parameters can be obtained. It is the sampling method used by HVI. HVI uses a fiber comb to sample cotton fibers and form a fiber beard for measuring fiber length parameters. A fundamental issue about this sampl...

  13. 7 CFR 32.402 - Samples of mohair top grades; method of obtaining.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Samples of mohair top grades; method of obtaining. 32... STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.402 Samples of mohair top grades; method of obtaining. Samples certified as representative of the official standards of...

  14. 7 CFR 32.402 - Samples of mohair top grades; method of obtaining.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Samples of mohair top grades; method of obtaining. 32... STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.402 Samples of mohair top grades; method of obtaining. Samples certified as representative of the official standards of...

  15. 7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Samples for wool and wool top grades; method of... STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool and wool top grades; method of obtaining. Samples certified as representative of the...

  16. 7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Samples for wool and wool top grades; method of... STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool and wool top grades; method of obtaining. Samples certified as representative of the...

  17. 7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Samples for wool and wool top grades; method of... STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool and wool top grades; method of obtaining. Samples certified as representative of the...

  18. 7 CFR 32.402 - Samples of mohair top grades; method of obtaining.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Samples of mohair top grades; method of obtaining. 32... STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.402 Samples of mohair top grades; method of obtaining. Samples certified as representative of the official standards of...

  19. 7 CFR 32.402 - Samples of mohair top grades; method of obtaining.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Samples of mohair top grades; method of obtaining. 32... STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.402 Samples of mohair top grades; method of obtaining. Samples certified as representative of the official standards of...

  20. 7 CFR 31.400 - Samples for wool and wool top grades; method of obtaining.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Samples for wool and wool top grades; method of... STANDARDS AND STANDARD CONTAINER REGULATIONS PURCHASE OF WOOL AND WOOL TOP SAMPLES § 31.400 Samples for wool and wool top grades; method of obtaining. Samples certified as representative of the...

  1. 7 CFR 32.402 - Samples of mohair top grades; method of obtaining.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Samples of mohair top grades; method of obtaining. 32... STANDARD CONTAINER REGULATIONS PURCHASE OF GREASE MOHAIR AND MOHAIR TOP SAMPLES § 32.402 Samples of mohair top grades; method of obtaining. Samples certified as representative of the official standards of...

  2. Rapid method to determine 89Sr/90Sr in large concrete samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; Utsey, Robin C.; Sudowe, Ralf; McAlister, Daniel R.

    2016-03-24

    Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g-1. The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90Sr from 5-10 g concrete samples. When, the 89Sr/90Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90Sr measured, and then 90Sr determined via 90Y separated after amore » period of ingrowth. Another approach allows the immediate determination of 90Sr in 10 g concrete aliquots without waiting for 90Y ingrowth, in instances where the shorter lived 89Sr is unlikely to be encountered.« less

  3. 40 CFR 761.243 - Standard wipe sample method and size.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.243 Standard wipe sample method and size. (a) Collect a surface sample from a natural gas... June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at...

  4. 40 CFR 761.243 - Standard wipe sample method and size.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.243 Standard wipe sample method and size. (a) Collect a surface sample from a natural gas... June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at...

  5. 40 CFR 761.243 - Standard wipe sample method and size.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.243 Standard wipe sample method and size. (a) Collect a surface sample from a natural gas... June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at...

  6. 40 CFR 761.243 - Standard wipe sample method and size.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.243 Standard wipe sample method and size. (a) Collect a surface sample from a natural gas... June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at...

  7. 40 CFR 761.243 - Standard wipe sample method and size.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Natural Gas Pipeline: Selecting Sample Sites, Collecting Surface Samples, and Analyzing Standard PCB Wipe Samples § 761.243 Standard wipe sample method and size. (a) Collect a surface sample from a natural gas... June 23, 1987 and revised on April 18, 1991. This document is available on EPA's Web site at...

  8. TESTING METHODS FOR DETECTION OF CRYPTOSPORIDIUM SPP. IN WATER SAMPLES

    EPA Science Inventory

    A large waterborne outbreak of cryptosporidiosis in Milwaukee, Wisconsin, U.S.A. in 1993 prompted a search for ways to prevent large-scale waterborne outbreaks of protozoan parasitoses. Methods for detecting Cryptosporidium parvum play an integral role in strategies that lead to...

  9. A New IRT-Based Small Sample DIF Method.

    ERIC Educational Resources Information Center

    Tang, Huixing

    This paper describes an item response theory (IRT) based method of differential item functioning (DIF) detection that involves neither separate calibration nor ability grouping. IRT is used to generate residual scores, scores free of the effects of person or group ability and item difficulty. Analysis of variance is then used to test the group…

  10. COMPARISON OF LARGE RIVER SAMPLING METHODS ON ALGAL METRICS

    EPA Science Inventory

    We compared the results of four methods used to assess the algal communities at 60 sites distributed among four rivers. Based on Principle Component Analysis of physical habitat data collected concomitantly with the algal data, sites were separated into those with a mean thalweg...

  11. COMPARISON OF LARGE RIVER SAMPLING METHOD USING DIATOM METRICS

    EPA Science Inventory

    We compared the results of four methods used to assess the algal communities at 60 sites distributed among four rivers. Based on Principle Component Analysis of physical habitat data collected concomitantly with the algal data, sites were separated into those with a mean thalweg...

  12. High-throughput liquid-absorption preconcentrator sampling methods

    DOEpatents

    Zaromb, Solomon

    1994-01-01

    A system for detecting trace concentrations of an analyte in air includes a preconcentrator for the analyte and an analyte detector. The preconcentrator includes an elongated tubular container comprising a wettable material. The wettable material is continuously wetted with an analyte-sorbing liquid which flows from one part of the container to a lower end. Sampled air flows through the container in contact with the wetted material with a swirling motion which results in efficient transfer of analyte vapors or aerosol particles to the sorbing liquid and preconcentration of traces of analyte in the liquid. The preconcentrated traces of analyte may be either detected within the container or removed therefrom for injection into a separate detection means or for subsequent analysis.

  13. Importance Sampling Approach for the Nonstationary Approximation Error Method

    NASA Astrophysics Data System (ADS)

    Huttunen, J. M. J.; Lehikoinen, A.; Hämäläinen, J.; Kaipio, J. P.

    2010-09-01

    The approximation error approach has been earlier proposed to handle modelling, numerical and computational errors in inverse problems. The idea of the approach is to include the errors to the forward model and compute the approximate statistics of the errors using Monte Carlo sampling. This can be a computationally tedious task but the key property of the approach is that the approximate statistics can be calculated off-line before measurement process takes place. In nonstationary problems, however, information is accumulated over time, and the initial uncertainties may turn out to have been exaggerated. In this paper, we propose an importance weighing algorithm with which the approximation error statistics can be updated during the accumulation of measurement information. As a computational example, we study an estimation problem that is related to a convection-diffusion problem in which the velocity field is not accurately specified.

  14. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    SciTech Connect

    Not Available

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE`s Office of EM (Environmental Restoration and Waste Management).

  15. Precise method for the measurement of catalase activity in honey.

    PubMed

    Huidobro, José F; Sánchez, M Pilar; Muniategui, Soledad; Sancho, M Teresa

    2005-01-01

    An improved method is reported for the determination of catalase activity in honey. We tested different dialysis membranes, dialysis fluid compositions and amounts, dialysis temperatures, sample amounts, and dialysis times. The best results were obtained by dialysis of 7.50 g sample in a cellulose dialysis sack, using two 3 L portions of 0.015 M sodium phosphate buffer (pH 7.0) as the dialysis fluid at 4 degrees C for 22 h. As in previous methods, catalase activity was determined on the basis of the rate of disappearance of the substrate, H202, with the H202 determined spectrophotometrically at 400 nm in an assay system containing o-dianisidine and peroxidase. Trials indicated that the best solvent for the o-dianisidine was 0.2 M sodium phosphate buffer, pH 6.1; the best starting H202 concentration was 3 mM; the best HCl concentration for stopping the reaction was 6 N; and the best sample volume for catalase measurement was 7.0 mL. Precision values (relative standard deviations for analyses of 10 subsamples of each of 3 samples) were high, ranging from 0.48% for samples with high catalase activity to 1.98% for samples with low catalase activity.

  16. Microwave acid digestion and preconcentration neutron activation analysis of biological and diet samples for iodine.

    PubMed

    Rao, R R; Chatt, A

    1991-07-01

    A simple preconcentration neutron activation analysis (PNAA) method has been developed for the determination of low levels of iodine in biological and nutritional materials. The method involves dissolution of the samples by microwave digestion in the presence of acids in closed Teflon bombs and preconcentration of total iodine, after reduction to iodide with hydrazine sulfate, by coprecipitation with bismuth sulfide. The effects of different factors such as acidity, time for complete precipitation, and concentrations of bismuth, sulfide, and diverse ions on the quantitative recovery of iodide have been studied. The absolute detection limit of the PNAA method is 5 ng of iodine. Precision of measurement, expressed in terms of relative standard deviation, is about 5% at 100 ppb and 10% at 20 ppb levels of iodine. The PNAA method has been applied to several biological reference materials and total diet samples. PMID:1897721

  17. Microwave acid digestion and preconcentration neutron activation analysis of biological and diet samples for iodine.

    PubMed

    Rao, R R; Chatt, A

    1991-07-01

    A simple preconcentration neutron activation analysis (PNAA) method has been developed for the determination of low levels of iodine in biological and nutritional materials. The method involves dissolution of the samples by microwave digestion in the presence of acids in closed Teflon bombs and preconcentration of total iodine, after reduction to iodide with hydrazine sulfate, by coprecipitation with bismuth sulfide. The effects of different factors such as acidity, time for complete precipitation, and concentrations of bismuth, sulfide, and diverse ions on the quantitative recovery of iodide have been studied. The absolute detection limit of the PNAA method is 5 ng of iodine. Precision of measurement, expressed in terms of relative standard deviation, is about 5% at 100 ppb and 10% at 20 ppb levels of iodine. The PNAA method has been applied to several biological reference materials and total diet samples.

  18. Non-invasive methods for estradiol recovery from infant fecal samples.

    PubMed

    Thompson, Amanda L; Whitten, Patricia L; Johnson, Michael L; Lampl, Michelle

    2010-01-01

    While the activation of the infant hypothalamic-pituitary-gonadal axis and the existence of a postnatal gonadotropin surge were first documented in the early 1970s, study of the longitudinal development of gonadal hormones in infancy, and the potential physiological and behavioral correlates of this development, have been hampered by reliance on infrequent serum sampling. The present study reports the validation of a non-invasive method for repeated assessment of steroid hormones in infant fecal samples. Fecal samples were collected in and excised from cotton diaper liners and extracted using methanol. Extracts were analyzed for estradiol using a diluted assay modification. Method validity was supported by a steroid recovery rate of at least 80%, a sensitivity of 0.35 pg/ml, and inter- and intra-assay coefficients of variations of less than 10 and 20%, respectively. Variation in estradiol concentration was assessed across (1) sample type (scraped vs. cut from diaper liner), (2) time of day (morning vs. afternoon/evening samples), (3) time interval between samples, and (4) time-to-assay (1 day vs. 489 days after collection). Of these characteristics, only the time interval between samples within an individual was significantly associated with estradiol concentration. This is the first report of human infant fecal estradiol levels. The results support fecal recovery as a novel and powerful non-invasive tool for longitudinal studies of human infants, expanding research opportunities for investigating development of sex-specific behaviors in infancy, and the potential effects of endocrine disruptors on development.

  19. Estimated neutron-activation data for TFTR. Part II. Biological dose rate from sample-materials activation

    SciTech Connect

    Ku, L.; Kolibal, J.G.

    1982-06-01

    The neutron induced material activation dose rate data are summarized for the TFTR operation. This report marks the completion of the second phase of the systematic study of the activation problem on the TFTR. The estimations of the neutron induced activation dose rates were made for spherical and slab objects, based on a point kernel method, for a wide range of materials. The dose rates as a function of cooling time for standard samples are presented for a number of typical neutron spectrum expected during TFTR DD and DT operations. The factors which account for the variations of the pulsing history, the characteristic size of the object and the distance of observation relative to the standard samples are also presented.

  20. Tissue sampling methods and standards for vertebrate genomics

    PubMed Central

    2012-01-01

    The recent rise in speed and efficiency of new sequencing technologies have facilitated high-throughput sequencing, assembly and analyses of genomes, advancing ongoing efforts to analyze genetic sequences across major vertebrate groups. Standardized procedures in acquiring high quality DNA and RNA and establishing cell lines from target species will facilitate these initiatives. We provide a legal and methodological guide according to four standards of acquiring and storing tissue for the Genome 10K Project and similar initiatives as follows: four-star (banked tissue/cell cultures, RNA from multiple types of tissue for transcriptomes, and sufficient flash-frozen tissue for 1 mg of DNA, all from a single individual); three-star (RNA as above and frozen tissue for 1 mg of DNA); two-star (frozen tissue for at least 700 μg of DNA); and one-star (ethanol-preserved tissue for 700 μg of DNA or less of mixed quality). At a minimum, all tissues collected for the Genome 10K and other genomic projects should consider each species’ natural history and follow institutional and legal requirements. Associated documentation should detail as much information as possible about provenance to ensure representative sampling and subsequent sequencing. Hopefully, the procedures outlined here will not only encourage success in the Genome 10K Project but also inspire the adaptation of standards by other genomic projects, including those involving other biota. PMID:23587255

  1. METHOD OF SUPPRESSING GASTROINTESTINAL UREASE ACTIVITY

    DOEpatents

    Visek, W.J.

    1963-04-23

    This patent shows a method of increasing the growth rate of chicks. Certain diacyl substituted ureas such as alloxan, murexide, and barbituric acid are added to their feed, thereby suppressing gastrointestinal urease activity and thus promoting growth. (AEC)

  2. [Methods for determination of cholinesterase activity].

    PubMed

    Dingová, D; Hrabovská, A

    2015-01-01

    Cholinesterases hydrolyze acetylcholine and thus they play a key role in a process of cholinergic neurotransmission. Changes in their activities are linked to many diseases (e.g Alzheimer disease, Parkinson disease, lipid disorders). Thus, it is important to determine their activity in a fast, simply and precise way. In this review, different approaches of studying cholinesterase activities (e.g pH-dependent, spectrophotometric, radiometric, histochemical methods or biosensors) are discussed. Comparisons, advantages or disadvantages of selected methods (e.g most widely used Ellman's assay, extremely sensitive Johnson Russell method or modern technique with golden nanoparticles) are presented. This review enables one to choose a suitable method for determination of cholinesterase activities with respect to laboratory equipment, type of analysis, pH, temperature scale or special conditions. PMID:26852525

  3. A sampling method for conducting relocation studies with freshwater mussels

    USGS Publications Warehouse

    Waller, D.L.; Rach, J.J.; Cope, W.G.; Luoma, J.A.

    1993-01-01

    Low recovery of transplanted mussels often prevents accurate estimates of survival. We developed a method that provided a high recovery of transplanted mussels and allowed for a reliable assessment of mortality. A 3 x 3 m polyvinyl chloride (PVC) pipe grid was secured to the sediment with iron reinforcing bars. The grid was divided into nine 1-m super(2) segments and each treatment segment, was stocked with 100 marked mussels. The recovery of mussels after six months exceeded 80% in all but one treatment group.

  4. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, T.D.; Beller, L.S.; Clark, M.L.; Klingler, K.M.

    1997-10-14

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: (a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; (b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; (c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and (d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus is also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container. 8 figs.

  5. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, Terry D.; Beller, Laurence S.; Clark, Michael L.; Klingler, Kerry M.

    1997-01-01

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus are also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container.

  6. Random Sampling of Quantum States: a Survey of Methods. And Some Issues Regarding the Overparametrized Method

    NASA Astrophysics Data System (ADS)

    Maziero, Jonas

    2015-12-01

    The numerical generation of random quantum states (RQS) is an important procedure for investigations in quantum information science. Here, we review some methods that may be used for performing that task. We start by presenting a simple procedure for generating random state vectors, for which the main tool is the random sampling of unbiased discrete probability distributions (DPD). Afterwards, the creation of random density matrices is addressed. In this context, we first present the standard method, which consists in using the spectral decomposition of a quantum state for getting RQS from random DPDs and random unitary matrices. In the sequence, the Bloch vector parametrization method is described. This approach, despite being useful in several instances, is not in general convenient for RQS generation. In the last part of the article, we regard the overparametrized method (OPM) and the related Ginibre and Bures techniques. The OPM can be used to create random positive semidefinite matrices with unit trace from randomly produced general complex matrices in a simple way that is friendly for numerical implementations. We consider a physically relevant issue related to the possible domains that may be used for the real and imaginary parts of the elements of such general complex matrices. Subsequently, a too fast concentration of measure in the quantum state space that appears in this parametrization is noticed.

  7. Paraoxonase-1 Enzyme Activity Assay for Clinical Samples: Validation and Correlation Studies

    PubMed Central

    Garelnabi, Mahdi; Younis, Abdelmoneim

    2015-01-01

    Background Paraoxonase-1 (PON1) enzyme is reported in various types of tissues and linked to numerous pathophysiological disorders. It is a potential biomarker in many pathological conditions such as cardiovascular diseases. Material/Methods We conducted several small-scale studies to evaluate PON1 performance as affected by sample types, storage, and interferences. We also carried out short-term studies to compare the performance of the widely used PON1 assay to the similar commercially available PON1 kit assay method; sample size for the method comparison was N=40, and the number varied for other validation experiments. Results Our studies using various types of anticoagulants show that samples collected in tubes with NaF, citrate, EDTA, clot activator, and sodium heparin have increased PON1 levels that are 49%, 24.5%, 19.8%, 11.4%, and 8%, respectively, higher compared to serum samples collected in plain tubes. However, samples collected in lithium heparin tubes demonstrated 10.4% lower PON1 levels compared to serum collected in plain tubes. Biological interference such as hemolysis has little effect on PON1 levels; however, samples spiked with lipids have shown 13% lower PON 1 levels. Our studies comparing the PON1 method commonly available for PON1 assay and a similar non-ELISA commercially available PON1 kit method showed a weak Spearman correlation coefficient of R2=0.40 for the range of 104.9–245.6 U/L. Conclusions The current study provides new validation data on enzyme PON1 performance. While no appreciable change was seen with storage, samples type affects the enzyme performance. Our results should encourage additional clinical studies to investigate other aspects of factors known to affect PON1 enzyme function and performance. PMID:25814092

  8. Encapsulation method for maintaining biodecontamination activity

    DOEpatents

    Rogers, Robert D.; Hamilton, Melinda A.; Nelson, Lee O.; Benson, Jennifer; Green, Martin J.; Milner, Timothy N.

    2006-04-11

    A method for maintaining the viability and subsequent activity of microorganisms utilized in a variety of environments to promote biodecontamination of surfaces. One application involves the decontamination of concrete surfaces. Encapsulation of microbial influenced degradation (MID) microorganisms has shown that MID activity is effectively maintained under passive conditions, that is, without manual addition of moisture or nutrients, for an extended period of time.

  9. Encapsulation method for maintaining biodecontamination activity

    DOEpatents

    Rogers, Robert D.; Hamilton, Melinda A.; Nelson, Lee O.; Benson, Jennifer; Green, Martin J.; Milner, Timothy N.

    2002-01-01

    A method for maintaining the viability and subsequent activity of microorganisms utilized in a variety of environments to promote biodecontamination of surfaces. One application involves the decontamination of concrete surfaces. Encapsulation of microbial influenced degradation (MID) microorganisms has shown that MID activity is effectively maintained under passive conditions, that is, without manual addition of moisture or nutrients, for an extended period of time.

  10. Sampling and analytical methods of stable isotopes and dissolved inorganic carbon from CO2 injection sites

    NASA Astrophysics Data System (ADS)

    van Geldern, Robert; Myrttinen, Anssi; Becker, Veith; Barth, Johannes A. C.

    2010-05-01

    The isotopic composition (δ13C) of dissolved inorganic carbon (DIC), in combination with DIC concentration measurements, can be used to quantify geochemical trapping of CO2 in water. This is of great importance in monitoring the fate of CO2 in the subsurface in CO2 injection projects. When CO2 mixes with water, a shift in the δ13C values, as well as an increase in DIC concentrations is observed in the CO2-H2O system. However, when using standard on-site titration methods, it is often challenging to determining accurate in-situ DIC concentrations. This may be due to CO2 degassing and CO2-exchange between the sample and the atmosphere during titration, causing a change in the pH value or due to other unfavourable conditions such as turbid water samples or limited availability of fluid samples. A way to resolve this problem is by simultaneously determining the DIC concentration and carbon isotopic composition using a standard continuous flow Isotope Ratio Mass Spectrometry (CF-IRMS) setup with a Gasbench II coupled to Delta plusXP mass spectrometer. During sampling, in order to avoid atmospheric contact, water samples taken from the borehole-fluid-sampler should be directly transferred into a suitable container, such as a gasbag. Also, to avoid isotope fractionation due to biological activity in the sample, it is recommended to stabilize the gasbags prior to sampling with HgCl2 for the subsequent stable isotope analysis. The DIC concentration of the samples can be determined from the area of the sample peaks in a chromatogram from a CF-IRMS analysis, since it is directly proportional to the CO2 generated by the reaction of the water with H3PO4. A set of standards with known DIC concentrations should be prepared by mixing NaHCO3 with DIC free water. Since the DIC concentrations of samples taken from CO2 injection sites are expected to be exceptionally high due to the additional high amounts of added CO2, the DIC concentration range of the standards should be set high

  11. Determination of methylmercury in marine biota samples: method validation.

    PubMed

    Carrasco, Luis; Vassileva, Emilia

    2014-05-01

    Regulatory authorities are expected to measure concentration of contaminants in foodstuffs, but the simple determination of total amount cannot be sufficient for fully judging its impact on the human health. In particular, the methylation of metals generally increases their toxicity; therefore validated analytical methods producing reliable results for the assessment of methylated species are highly needed. Nowadays, there is no legal limit for methylmercury (MeHg) in food matrices. Hence, no standardized method for the determination of MeHg exists within the international jurisdiction. Contemplating the possibility of a future legislative limit, a method for low level determination of MeHg in marine biota matrixes, based on aqueous-phase ethylation followed by purge and trap and gas chromatography (GC) coupled to pyrolysis-atomic fluorescence spectrometry (Py-AFS) detection, has been developed and validated. Five different extraction procedures, namely acid and alkaline leaching assisted by microwave and conventional oven heating, as well as enzymatic digestion, were evaluated in terms of their efficiency to extract MeHg from Scallop soft tissue IAEA-452 Certified Reference Material. Alkaline extraction with 25% (w/w) KOH in methanol, microwave-assisted extraction (MAE) with 5M HCl and enzymatic digestion with protease XIV yielded the highest extraction recoveries. Standard addition or the introduction of a dilution step were successfully applied to overcome the matrix effects observed when microwave-assisted extraction using 25% (w/w) KOH in methanol or 25% (w/v) aqueous TMAH were used. ISO 17025 and Eurachem guidelines were followed to perform the validation of the methodology. Accordingly, blanks, selectivity, calibration curve, linearity (0.9995), working range (1-800pg), recovery (97%), precision, traceability, limit of detection (0.45pg), limit of quantification (0.85pg) and expanded uncertainty (15.86%, k=2) were assessed with Fish protein Dorm-3 Certified

  12. Determination of optimal sampling times for a two blood sample clearance method using (51)Cr-EDTA in cats.

    PubMed

    Vandermeulen, Eva; De Sadeleer, Carlos; Piepsz, Amy; Ham, Hamphrey R; Dobbeleir, André A; Vermeire, Simon T; Van Hoek, Ingrid M; Daminet, Sylvie; Slegers, Guido; Peremans, Kathelijne Y

    2010-08-01

    Estimation of the glomerular filtration rate (GFR) is a useful tool in the evaluation of kidney function in feline medicine. GFR can be determined by measuring the rate of tracer disappearance from the blood, and although these measurements are generally performed by multi-sampling techniques, simplified methods are more convenient in clinical practice. The optimal times for a simplified sampling strategy with two blood samples (2BS) for GFR measurement in cats using plasma (51)chromium ethylene diamine tetra-acetic acid ((51)Cr-EDTA) clearance were investigated. After intravenous administration of (51)Cr-EDTA, seven blood samples were obtained in 46 cats (19 euthyroid and 27 hyperthyroid cats, none with previously diagnosed chronic kidney disease (CKD)). The plasma clearance was then calculated from the seven point blood kinetics (7BS) and used for comparison to define the optimal sampling strategy by correlating different pairs of time points to the reference method. Mean GFR estimation for the reference method was 3.7+/-2.5 ml/min/kg (mean+/-standard deviation (SD)). Several pairs of sampling times were highly correlated with this reference method (r(2) > or = 0.980), with the best results when the first sample was taken 30 min after tracer injection and the second sample between 198 and 222 min after injection; or with the first sample at 36 min and the second at 234 or 240 min (r(2) for both combinations=0.984). Because of the similarity of GFR values obtained with the 2BS method in comparison to the values obtained with the 7BS reference method, the simplified method may offer an alternative for GFR estimation. Although a wide range of GFR values was found in the included group of cats, the applicability should be confirmed in cats suspected of renal disease and with confirmed CKD. Furthermore, although no indications of age-related effect were found in this study, a possible influence of age should be included in future studies. PMID:20452793

  13. Sparsity-weighted outlier FLOODing (OFLOOD) method: Efficient rare event sampling method using sparsity of distribution.

    PubMed

    Harada, Ryuhei; Nakamura, Tomotake; Shigeta, Yasuteru

    2016-03-30

    As an extension of the Outlier FLOODing (OFLOOD) method [Harada et al., J. Comput. Chem. 2015, 36, 763], the sparsity of the outliers defined by a hierarchical clustering algorithm, FlexDice, was considered to achieve an efficient conformational search as sparsity-weighted "OFLOOD." In OFLOOD, FlexDice detects areas of sparse distribution as outliers. The outliers are regarded as candidates that have high potential to promote conformational transitions and are employed as initial structures for conformational resampling by restarting molecular dynamics simulations. When detecting outliers, FlexDice defines a rank in the hierarchy for each outlier, which relates to sparsity in the distribution. In this study, we define a lower rank (first ranked), a medium rank (second ranked), and the highest rank (third ranked) outliers, respectively. For instance, the first-ranked outliers are located in a given conformational space away from the clusters (highly sparse distribution), whereas those with the third-ranked outliers are nearby the clusters (a moderately sparse distribution). To achieve the conformational search efficiently, resampling from the outliers with a given rank is performed. As demonstrations, this method was applied to several model systems: Alanine dipeptide, Met-enkephalin, Trp-cage, T4 lysozyme, and glutamine binding protein. In each demonstration, the present method successfully reproduced transitions among metastable states. In particular, the first-ranked OFLOOD highly accelerated the exploration of conformational space by expanding the edges. In contrast, the third-ranked OFLOOD reproduced local transitions among neighboring metastable states intensively. For quantitatively evaluations of sampled snapshots, free energy calculations were performed with a combination of umbrella samplings, providing rigorous landscapes of the biomolecules.

  14. [Comparative Analysis of Spectrophotometric Methods of the Protein Measurement in the Pectic Polysaccharide Samples].

    PubMed

    Ponomareva, S A; Golovchenko, V V; Patova, O A; Vanchikova, E V; Ovodov, Y S

    2015-01-01

    For the assay to reliability of determination of the protein content in the pectic polysaccharide samples by absorbance in the ultraviolet and visible regions of the spectrum a comparison of the eleven techniques called Flores, Lovry, Bradford, Sedmak, Rueman (ninhydrin reaction) methods, the method of ultraviolet spectrophotometry, the method Benedict's reagent, the method Nessler's reagent, the method with amide black, the bicinchoninic reagent and the biuret method was carried out. The data obtained show that insufficient sensitivity of the seven methods from the listed techniques doesn't allow their usage for determination of protein content in pectic polysaccharide samples. But the Lowry, Bradford, Sedmak methods, and the method Nessler's reagent may be used for determination of protein content in pectic polysaccharide samples, and the Bradford method is advisable for protein contaminants content determination in pectic polysaccharide samples in case protein content is less than 15%, and the Lowry method--for samples is more than 15%. PMID:26165122

  15. Method for sequential injection of liquid samples for radioisotope separations

    DOEpatents

    Egorov, Oleg B.; Grate, Jay W.; Bray, Lane A.

    2000-01-01

    The present invention is a method of separating a short-lived daughter isotope from a longer lived parent isotope, with recovery of the parent isotope for further use. Using a system with a bi-directional pump and one or more valves, a solution of the parent isotope is processed to generate two separate solutions, one of which contains the daughter isotope, from which the parent has been removed with a high decontamination factor, and the other solution contains the recovered parent isotope. The process can be repeated on this solution of the parent isotope. The system with the fluid drive and one or more valves is controlled by a program on a microprocessor executing a series of steps to accomplish the operation. In one approach, the cow solution is passed through a separation medium that selectively retains the desired daughter isotope, while the parent isotope and the matrix pass through the medium. After washing this medium, the daughter is released from the separation medium using another solution. With the automated generator of the present invention, all solution handling steps necessary to perform a daughter/parent radionuclide separation, e.g. Bi-213 from Ac-225 "cow" solution, are performed in a consistent, enclosed, and remotely operated format. Operator exposure and spread of contamination are greatly minimized compared to the manual generator procedure described in U.S. patent application Ser. No. 08/789,973, now U.S. Pat. No. 5,749,042, herein incorporated by reference. Using 16 mCi of Ac-225 there was no detectable external contamination of the instrument components.

  16. Measurement of bedload transport in sand-bed rivers: a look at two indirect sampling methods

    USGS Publications Warehouse

    Holmes, Robert R.; Gray, John R.; Laronne, Jonathan B.; Marr, Jeffrey D.G.

    2010-01-01

    Sand-bed rivers present unique challenges to accurate measurement of the bedload transport rate using the traditional direct sampling methods of direct traps (for example the Helley-Smith bedload sampler). The two major issues are: 1) over sampling of sand transport caused by “mining” of sand due to the flow disturbance induced by the presence of the sampler and 2) clogging of the mesh bag with sand particles reducing the hydraulic efficiency of the sampler. Indirect measurement methods hold promise in that unlike direct methods, no transport-altering flow disturbance near the bed occurs. The bedform velocimetry method utilizes a measure of the bedform geometry and the speed of bedform translation to estimate the bedload transport through mass balance. The bedform velocimetry method is readily applied for the estimation of bedload transport in large sand-bed rivers so long as prominent bedforms are present and the streamflow discharge is steady for long enough to provide sufficient bedform translation between the successive bathymetric data sets. Bedform velocimetry in small sandbed rivers is often problematic due to rapid variation within the hydrograph. The bottom-track bias feature of the acoustic Doppler current profiler (ADCP) has been utilized to accurately estimate the virtual velocities of sand-bed rivers. Coupling measurement of the virtual velocity with an accurate determination of the active depth of the streambed sediment movement is another method to measure bedload transport, which will be termed the “virtual velocity” method. Much research remains to develop methods and determine accuracy of the virtual velocity method in small sand-bed rivers.

  17. Initial evaluation of Centroidal Voronoi Tessellation method for statistical sampling and function integration.

    SciTech Connect

    Romero, Vicente Jose; Peterson, Janet S.; Burkhardt, John V.; Gunzburger, Max Donald

    2003-09-01

    A recently developed Centroidal Voronoi Tessellation (CVT) unstructured sampling method is investigated here to assess its suitability for use in statistical sampling and function integration. CVT efficiently generates a highly uniform distribution of sample points over arbitrarily shaped M-Dimensional parameter spaces. It has recently been shown on several 2-D test problems to provide superior point distributions for generating locally conforming response surfaces. In this paper, its performance as a statistical sampling and function integration method is compared to that of Latin-Hypercube Sampling (LHS) and Simple Random Sampling (SRS) Monte Carlo methods, and Halton and Hammersley quasi-Monte-Carlo sequence methods. Specifically, sampling efficiencies are compared for function integration and for resolving various statistics of response in a 2-D test problem. It is found that on balance CVT performs best of all these sampling methods on our test problems.

  18. Recent developments on field gas extraction and sample preparation methods for radiokrypton dating of groundwater

    NASA Astrophysics Data System (ADS)

    Yokochi, Reika

    2016-09-01

    Current and foreseen population growths will lead to an increased demand in freshwater, large quantities of which is stored as groundwater. The ventilation age is crucial to the assessment of groundwater resources, complementing the hydrological model approach based on hydrogeological parameters. Ultra-trace radioactive isotopes of Kr (81 Kr and 85 Kr) possess the ideal physical and chemical properties for groundwater dating. The recent advent of atom trap trace analyses (ATTA) has enabled determination of ultra-trace noble gas radioisotope abundances using 5-10 μ L of pure Kr. Anticipated developments will enable ATTA to analyze radiokrypton isotope abundances at high sample throughput, which necessitates simple and efficient sample preparation techniques that are adaptable to various sample chemistries. Recent developments of field gas extraction devices and simple and rapid Kr separation method at the University of Chicago are presented herein. Two field gas extraction devices optimized for different sampling conditions were recently designed and constructed, aiming at operational simplicity and portability. A newly developed Kr purification system enriches Kr by flowing a sample gas through a moderately cooled (138 K) activated charcoal column, followed by a gentle fractionating desorption. This simple process uses a single adsorbent and separates 99% of the bulk atmospheric gases from Kr without significant loss. The subsequent two stages of gas chromatographic separation and a hot Ti sponge getter further purify the Kr-enriched gas. Abundant CH4 necessitates multiple passages through one of the gas chromatographic separation columns. The presented Kr separation system has a demonstrated capability of extracting Kr with > 90% yield and 99% purity within 75 min from 1.2 to 26.8 L STP of atmospheric air with various concentrations of CH4. The apparatuses have successfully been deployed for sampling in the field and purification of groundwater samples.

  19. A Typology of Mixed Methods Sampling Designs in Social Science Research

    ERIC Educational Resources Information Center

    Onwuegbuzie, Anthony J.; Collins, Kathleen M. T.

    2007-01-01

    This paper provides a framework for developing sampling designs in mixed methods research. First, we present sampling schemes that have been associated with quantitative and qualitative research. Second, we discuss sample size considerations and provide sample size recommendations for each of the major research designs for quantitative and…

  20. Comparison of Gingival Crevicular Fluid Sampling Methods in Patients with Severe Chronic Periodontitis

    PubMed Central

    Guentsch, Arndt; Kramesberger, Martin; Sroka, Aneta; Pfister, Wolfgang; Potempa, Jan; Eick, Sigrun

    2011-01-01

    Background Analysis of samplings from periodontal pockets is important in diagnosis and therapy control of periodontitis. In this study, three different sampling techniques were compared to determine if one method can yield samples suitable for reproducible and simultaneous determination of bacterial load, cytokines, neutrophil elastase, and Arg-specific gingipains. R-gingipains are an important virulence factor of Porphyromonas gingivalis, the exact concentration of which in gingival crevicular fluid (GCF) has not yet been quantified. Methods GCF was sampled from four sites per patient (each two sites one method) in 36 chronic periodontitis patients. One week later, the procedure was repeated with alternative methods. The variables that had been determined were: loads of Aggregatibacter actinomycetemcomitans and P. gingivalis, levels of interleukin-6 and interleukin-8, activity of neutrophil elastase and level of R-gingipains. Results The detected cytokine levels were higher using paper strips compared to paper points. Bacteria were found in similar loads from the paper strips and paper points. R-gingipains were detectable in high quantities only by washing of the periodontal pocket. The level of R-gingipains correlated with the load of P. gingivalis. Conclusion The use of paper strips is suitable for simultaneous determination of microbial and immunological parameters. Obtaining GCF by washing can be useful for special purposes. Gingipain concentration in periodontal pockets was directly determined to be up to 1.5 μM. This value indicates that most of so far identified substrates of these proteases by in vitro assays can be easily degraded in P. gingivalis infected sites. PMID:21235330

  1. A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions

    PubMed Central

    Pan, Guang; Ye, Pengcheng; Yang, Zhidong

    2014-01-01

    Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206

  2. Predictive Sampling of Rare Conformational Events in Aqueous Solution: Designing a Generalized Orthogonal Space Tempering Method

    PubMed Central

    Lv, Chao; Li, Xubin; Wu, Dongsheng; Zheng, Lianqing; Yang, Wei

    2016-01-01

    In aqueous solution, solute conformational transitions are governed by intimate interplays of the fluctuations of solute-solute, solute-water, and water-water interactions. To promote essential fluctuations to enhance sampling, a common strategy is to construct an expanded Hamiltonian through a series of Hamiltonian perturbations, for instance on certain interactions of focus. Due to lack of active sampling of configuration response to perturbation transitions, it is challenging for common expanded Hamiltonian methods to robustly explore solvent mediated rare conformational events. The orthogonal space sampling (OSS) scheme, as exemplified by the orthogonal space random walk and orthogonal space tempering methods, provides a general framework for synchronous acceleration of slow configuration responses. To more effectively sample conformational transitions in aqueous solution, in this work, we devised a generalized orthogonal space tempering (gOST) algorithm. Specifically, in the Hamiltonian perturbation part, a solvent-accessible-surface-area-dependent term is introduced to implicitly perturb near-solute water-water fluctuations; and in the orthogonal space response part, the generalized force order parameter is generalized as a two-dimension order parameter set, in which the solute-solvent and solute-solute components are separately treated. The gOST algorithm is evaluated through a molecular dynamics simulation study on the explicitly-solvated deca-alanine (Ala10) peptide. Based on a fully automated sampling protocol, the gOST simulation enabled repetitive folding and unfolding of the solvated peptide within a single continuous trajectory and allowed for detailed constructions of Ala10 folding/unfolding free energy surfaces. The gOST result reveals that solvent cooperative fluctuations play a pivotal role in Ala10 folding/unfolding transitions. In addition, our assessment analysis suggests that because essential rare events are mainly driven by the compensating

  3. Fast and Specific Assessment of the Halogenating Peroxidase Activity in Leukocyte-enriched Blood Samples.

    PubMed

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2016-01-01

    In this paper a protocol for the quick and standardized enrichment of leukocytes from small whole blood samples is described. This procedure is based on the hypotonic lysis of erythrocytes and can be applied to human samples as well as to blood of non-human origin. The small initial sample volume of about 50 to 100 µl makes this method applicable to recurrent blood sampling from small laboratory animals. Moreover, leukocyte enrichment is achieved within minutes and with low material efforts regarding chemicals and instrumentation, making this method applicable in multiple laboratory environments. Standardized purification of leukocytes is combined with a highly selective staining method to evaluate halogenating peroxidase activity of the heme peroxidases, myeloperoxidase (MPO) and eosinophil peroxidase (EPO), i.e., the formation of hypochlorous and hypobromous acid (HOCl and HOBr). While MPO is strongly expressed in neutrophils, the most abundant immune cell type in human blood as well as in monocytes, the related enzyme EPO is exclusively expressed in eosinophils. The halogenating activity of these enzymes is addressed by using the almost HOCl- and HOBr-specific dye aminophenyl fluorescein (APF) and the primary peroxidase substrate hydrogen peroxide. Upon subsequent flow cytometry analysis all peroxidase-positive cells (neutrophils, monocytes, eosinophils) are distinguishable and their halogenating peroxidase activity can be quantified. Since APF staining may be combined with the application of cell surface markers, this protocol can be extended to specifically address leukocyte sub-fractions. The method is applicable to detect HOCl and HOBr production both in human and in rodent leukocytes. Given the widely and diversely discussed immunological role of these enzymatic products in chronic inflammatory diseases, this protocol may contribute to a better understanding of the immunological relevance of leukocyte-derived heme peroxidases. PMID:27501318

  4. Sample Energy Conservation Education Activities for Elementary School Students.

    ERIC Educational Resources Information Center

    Allen, Rodney F., Ed.; LaHart, David E., Ed.

    The booklet contains learning activities for introducing energy and conservation concepts into the existing elementary school curriculum. The activities were developed by Palm Beach County teachers during a one-week workshop. A framework of ideas is divided into three functional categories: universe of energy, living systems and energy, and social…

  5. Enhanced Sampling in Free Energy Calculations: Combining SGLD with the Bennett's Acceptance Ratio and Enveloping Distribution Sampling Methods.

    PubMed

    König, Gerhard; Miller, Benjamin T; Boresch, Stefan; Wu, Xiongwu; Brooks, Bernard R

    2012-10-01

    One of the key requirements for the accurate calculation of free energy differences is proper sampling of conformational space. Especially in biological applications, molecular dynamics simulations are often confronted with rugged energy surfaces and high energy barriers, leading to insufficient sampling and, in turn, poor convergence of the free energy results. In this work, we address this problem by employing enhanced sampling methods. We explore the possibility of using self-guided Langevin dynamics (SGLD) to speed up the exploration process in free energy simulations. To obtain improved free energy differences from such simulations, it is necessary to account for the effects of the bias due to the guiding forces. We demonstrate how this can be accomplished for the Bennett's acceptance ratio (BAR) and the enveloping distribution sampling (EDS) methods. While BAR is considered among the most efficient methods available for free energy calculations, the EDS method developed by Christ and van Gunsteren is a promising development that reduces the computational costs of free energy calculations by simulating a single reference state. To evaluate the accuracy of both approaches in connection with enhanced sampling, EDS was implemented in CHARMM. For testing, we employ benchmark systems with analytical reference results and the mutation of alanine to serine. We find that SGLD with reweighting can provide accurate results for BAR and EDS where conventional molecular dynamics simulations fail. In addition, we compare the performance of EDS with other free energy methods. We briefly discuss the implications of our results and provide practical guidelines for conducting free energy simulations with SGLD.

  6. Comparing Respondent-Driven Sampling and Targeted Sampling Methods of Recruiting Injection Drug Users in San Francisco

    PubMed Central

    Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N.; Lorvick, Jennifer; McFarland, Willi; Raymond, H. Fisher

    2010-01-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS. PMID:20582573

  7. Comparing respondent-driven sampling and targeted sampling methods of recruiting injection drug users in San Francisco.

    PubMed

    Kral, Alex H; Malekinejad, Mohsen; Vaudrey, Jason; Martinez, Alexis N; Lorvick, Jennifer; McFarland, Willi; Raymond, H Fisher

    2010-09-01

    The objective of this article is to compare demographic characteristics, risk behaviors, and service utilization among injection drug users (IDUs) recruited from two separate studies in San Francisco in 2005, one which used targeted sampling (TS) and the other which used respondent-driven sampling (RDS). IDUs were recruited using TS (n = 651) and RDS (n = 534) and participated in quantitative interviews that included demographic characteristics, risk behaviors, and service utilization. Prevalence estimates and 95% confidence intervals (CIs) were calculated to assess whether there were differences in these variables by sampling method. There was overlap in 95% CIs for all demographic variables except African American race (TS: 45%, 53%; RDS: 29%, 44%). Maps showed that the proportion of IDUs distributed across zip codes were similar for the TS and RDS sample, with the exception of a single zip code that was more represented in the TS sample. This zip code includes an isolated, predominantly African American neighborhood where only the TS study had a field site. Risk behavior estimates were similar for both TS and RDS samples, although self-reported hepatitis C infection was lower in the RDS sample. In terms of service utilization, more IDUs in the RDS sample reported no recent use of drug treatment and syringe exchange program services. Our study suggests that perhaps a hybrid sampling plan is best suited for recruiting IDUs in San Francisco, whereby the more intensive ethnographic and secondary analysis components of TS would aid in the planning of seed placement and field locations for RDS.

  8. {sup 222}Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    SciTech Connect

    Hightower, J.H. III

    1994-12-31

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA`s standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations.

  9. Microscopic and mesoscopic structural features of an activated carbon sample, prepared from sorghum via activation by phosphoric acid

    SciTech Connect

    Temleitner, László; Pusztai, László; Rubio-Arroyo, Manuel F.; Aguilar-López, Sergio; Pizio, Orest

    2012-12-15

    Graphical abstract: Display Omitted Highlights: ► Preparation of a new activated carbon sample from sorghum. ► Characterization by adsorption/desorption methods. ► Determination of the structure by synchrotron X-ray diffraction. ► The sample is amorphous and contains distorted graphene fragments. ► A characteristic nanoscale distance is established from the radial distribution function. -- Abstract: An acidic chemical activation procedure has been used for preparing activated carbon with a surface area exceeding 1000 m{sup 2}/g from sorghum. In order to reveal structural features, synchrotron X-ray diffraction measurements have been performed. The structure of the material has been characterized by the total scattering structure factor and the radial distribution function describing short-range arrangement of atoms at distances of the order of a few atomic diameters as well as correlations at a longer scale, of the order of nanometers. The atomic arrangement has been found to be consistent with that of amorphous graphite-like carbon. As far as the mesoscopic structure is concerned, the presence of a characteristic distance is suggested on the basis of the clear nanometer scale oscillations of the radial distribution function, which distance may be assigned as the mesopore size in the material. It is suggested that the approach devized here may later be applied routinely for other activated carbon samples, too, for characterizing atomic and nanoscale order simultaneously.

  10. Jazz Listening Activities: Children's Literature and Authentic Music Samples.

    ERIC Educational Resources Information Center

    McDonald, Nan L.; Fisher, Douglas; Helzer, Rick

    2002-01-01

    Describes a unit that is appropriate for upper elementary and middle school students that focuses on jazz music using biographies about jazz musicians. Discusses the five sections of the unit. Includes a list of "Suggested Jazz Listening Samples," jazz videos, and a bibliography of resources related to jazz music. (CMK)

  11. A method for measuring total thiaminase activity in fish tissues

    USGS Publications Warehouse

    Zajicek, J.L.; Tillitt, D.E.; Honeyfield, D.C.; Brown, S.B.; Fitzsimons, J.D.

    2005-01-01

    An accurate, quantitative, and rapid method for the measurement of thiaminase activity in fish samples is required to provide sufficient information to characterize the role of dietary thiaminase in the onset of thiamine deficiency in Great Lakes salmonines. A radiometric method that uses 14C-thiamine was optimized for substrate and co-substrate (nicotinic acid) concentrations, incubation time, and sample dilution. Total thiaminase activity was successfully determined in extracts of selected Great Lakes fishes and invertebrates. Samples included whole-body and selected tissues of forage fishes. Positive control material prepared from frozen alewives Alosa pseudoharengus collected in Lake Michigan enhanced the development and application of the method. The method allowed improved discrimination of thiaminolytic activity among forage fish species and their tissues. The temperature dependence of the thiaminase activity observed in crude extracts of Lake Michigan alewives followed a Q10 = 2 relationship for the 1-37??C temperature range, which is consistent with the bacterial-derived thiaminase I protein. ?? Copyright by the American Fisheries Society 2005.

  12. Differences in Movement Pattern and Detectability between Males and Females Influence How Common Sampling Methods Estimate Sex Ratio

    PubMed Central

    Rodrigues, João Fabrício Mota; Coelho, Marco Túlio Pacheco

    2016-01-01

    Sampling the biodiversity is an essential step for conservation, and understanding the efficiency of sampling methods allows us to estimate the quality of our biodiversity data. Sex ratio is an important population characteristic, but until now, no study has evaluated how efficient are the sampling methods commonly used in biodiversity surveys in estimating the sex ratio of populations. We used a virtual ecologist approach to investigate whether active and passive capture methods are able to accurately sample a population’s sex ratio and whether differences in movement pattern and detectability between males and females produce biased estimates of sex-ratios when using these methods. Our simulation allowed the recognition of individuals, similar to mark-recapture studies. We found that differences in both movement patterns and detectability between males and females produce biased estimates of sex ratios. However, increasing the sampling effort or the number of sampling days improves the ability of passive or active capture methods to properly sample sex ratio. Thus, prior knowledge regarding movement patterns and detectability for species is important information to guide field studies aiming to understand sex ratio related patterns. PMID:27441554

  13. 137Cs re-sampling as a method for soil erosion assessment in Alpine grasslands

    NASA Astrophysics Data System (ADS)

    Arata, Laura; Meusburger, Katrin; Bissig, Nicole; Mabit, Lionel; Alewell, Christine

    2014-05-01

    Over the past decades, radioactive fallout 137Cs has been used as a tracer to provide information on soil erosion and sedimentation rates. However, the method may produce relatively large uncertainties in Alpine grasslands. The latter difficulties are caused by a combination of (i) the heterogeneous distribution of atmospheric 137Cs Chernobyl fallout, (ii) the partly snow covered ground in Alpine areas during the fallout event in April 1986, which results in inhomogeneous 137Cs distribution during snow melt and (iii) uncertainties in finding undisturbed references sites in the geomorphological and anthropogenic highly active slopes of the Alps. To overcome these difficulties, our aim is to replace the classical 137Cs approach, where an undisturbed reference site is compared to erosional sites, with a re-sampling approach, where we re-sample sites which have already been measured for 137Cs inventories in the past. Thus, we use temporal instead of spatial reference. The study area is located in the Central Swiss Alps in the Urseren Valley. Potential erosional sites have been sampled in 2007 and re-sampled in 2012. Two different grassland types were investigated: hayfield (2 sites) and pasture without dwarf shrubs (3 sites). For each site, 4 to 9 sampling points have been defined, and at each point two soil samples have been collected. To reduce the random error, the two soil samples were bulked prior to gamma-analysis. 137Cs inventories of the two sampling years were calculated and used to assess recent soil erosion in the experimental sites. Our results show that within the 5 years measurable soil erosion and deposition processes have occurred within the sites, as indicated by the relevant difference between the 137Cs inventories of 2007 and 2012. 64% of the sites exhibit a decrease in 137Cs inventories, 20% of the sites an increase, and the remaining 16% no significant difference. In particular, hayfield sites have been affected by erosion processes, mostly due to

  14. Sample Size Determination: A Comparison of Attribute, Continuous Variable, and Cell Size Methods.

    ERIC Educational Resources Information Center

    Clark, Philip M.

    1984-01-01

    Describes three methods of sample size determination, each having its use in investigation of social science problems: Attribute method; Continuous Variable method; Galtung's Cell Size method. Statistical generalization, benefits of cell size method (ease of use, trivariate analysis and trichotyomized variables), and choice of method are…

  15. Enhanced Stability of Blood Matrices Using a Dried Sample Spot Assay to Measure Human Butyrylcholinesterase Activity and Nerve Agent Adducts

    PubMed Central

    Perez, Jonas W.; Pantazides, Brooke G.; Watson, Caroline M.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    Dried matrix spots are safer to handle and easier to store than wet blood products, but factors such as intra-spot variability and unknown sample volumes have limited their appeal as a sampling format for quantitative analyses. In this work, we introduce a dried spot activity assay for quantifying butyrylcholinesterase (BChE) specific activity which is BChE activity normalized to the total protein content in a sample spot. The method was demonstrated with blood, serum, and plasma spotted on specimen collection devices (cards) which were extracted to measure total protein and BChE activity using a modified Ellman assay. Activity recovered from dried spots was ∼80% of the initial spotted activity for blood and >90% for plasma and serum. Measuring total protein in the sample and calculating specific activity substantially improved quantification and reduced intra-spot variability. Analyte stability of nerve agent adducts was also evaluated, and the results obtained via BChE-specific activity measurements were confirmed by quantification of BChE adducts using a previously established LC-MS/MS method. The spotted samples were up to 10-times more resistant to degradation compared to unspotted control samples when measuring BChE inhibition by the nerve agents sarin and VX. Using this method, both BChE activity and adducts can be accurately measured from a dried sample spot. This use of a dried sample spot with normalization to total protein is robust, demonstrates decreased intra-spot variability without the need to control for initial sample volume, and enhances analyte stability. PMID:25955132

  16. Measurement of radon potential from soil using a special method of sampling

    NASA Astrophysics Data System (ADS)

    Cosma, Constantin; Papp, Botond; Moldovan, Mircea; Cosma, Victor; Cindea, Ciprian; Suciu, Liviu; Apostu, Adelina

    2010-10-01

    Soil radon gas and/or its exhalation rate are used as indicators for some applications, such as uranium exploration, indoor radon concentration, seismic activity, location of subsurface faults, etc., and also in the studies where the main interest is the field verification of radon transport models. This work proposes a versatile method for the soil radon sampling using a special manner of pumping. The soil gas is passed through a column of charcoal by using passive pumping. A plastic bottle filled with water is coupled to an activated charcoal column and the flow of water through an adjustable hole made at the bottom of bottle assures a controlled gas flow from the soil. The results obtained for the activity of activated charcoal are in the range of 20-40 kBq/m3, for a depth of approximately 0.8 m. The results obtained by this method were confirmed by simultaneous measurements using LUK 3C device for soil radon measurements. Possible applications for the estimation of radon soil potential are discussed.

  17. A method for sampling halothane and enflurane present in trace amounts in ambient air.

    PubMed

    Burm, A G; Spierdijk, J

    1979-03-01

    A method for the sampling of small amounts of halothane and enflurane in ambient air is described. Sampling is performed by drawing air through a sampling tube packed with Porapak Q, which absorbs the anesthetic agent. The amount absorbed is determined by gas chromatography after thermal desorption. This method can be used for "spot" or personal sampling or for determining mean whole-room concentrations over relatively long periods (several hours).

  18. Different methods for extracting bacteria from freshwater sediment and a simple method to measure bacterial production in sediment samples.

    PubMed

    dos Santos Furtado, A L; Casper, P

    2000-08-01

    The efficiency of different treatments was tested to extract bacterial cells from freshwater sediment samples. The influence of sonication, density gradient centrifugation, fixation by formalin and centrifugation speed on bacterial recovery was investigated. The method developed by Smith and Azam [Mar. Microb. Food Webs 6 (1992) 107] to measure microbial activity on bacterioplankton (3H-leucine incorporation), was also evaluated in sediment samples. After 1 min of sonication bacterial abundance was reduced by about 47% in diluted sediments with tetrasodium pyrophosphate. With the addition of Percoll after sonication, bacterial counts were not significantly different (P<0.05). Fixation by formalin increased bacterial counts using sonication. However, higher bacterial abundance was estimated in non-sonicated samples. Bacterial abundance in samples centrifuged at 7000xg with and without Percoll was not significantly different (P<0.05). Highest bacterial abundance was obtained after centrifugation at low speed (750xg). Bacterial abundance decreased with higher centrifugation speed (750, 1500 and 3000xg), the difference, however, was not significant. Bacterial production ranged from 0.10 microg C cm(-3) d(-1) in autoclaved sediment to 0. 27 microg C cm(-3) d(-1) in untreated sediment. The radioactivity measured in controls of both untreated and autoclaved sediment was high (70 and 91%, respectively), indicating a high level of leucine adsorption in sediment particles. In contrast, radioactivity in control samples previously centrifuged was markedly lower (6%). Despite the high values of radioactivity in the controls, bacterial production in untreated sediment was significantly higher than in centrifuged sediment (P<0.05).

  19. Sequential injection 90Sr determination in environmental samples using a wetting-film extraction method.

    PubMed

    Miró, Manuel; Gómez, Enrique; Estela, José Manuel; Casas, Montserrat; Cerdà, Victor

    2002-02-15

    A sequential injection procedure involving a flow-reversal wetting-film extraction method for the determination of the radionuclide 90Sr has been developed. The methodology is based on the coating of the inner walls of an open tubular reactor with a film prepared from a 0.14 M 4,4'(5')-bis(tert-butylcyclohexano)-18-crown-6 (BCHC) solution in 1-octanol, which allows the selective isolation of strontium from the sample matrix. Selection of the optimum extractant diluent attending its physical properties, investigation of the extraction kinetics features, and choice of the proper elution procedure are discussed in detail in this paper. The noteworthy aspects of using a wetting-film phase instead of a solid-phase material described to date in the literature are the reduction of crown ether consumption and the simplification of both the operational sequence and the automation of the extractant-phase renewal between consecutive samples, which is of interest to avoid analyte carryover and reduction of the resin capacity factor caused by irreversible interferences. The proposed method has been successfully applied to different spiked environmental samples (water, milk, and soil), with 90Sr total activities ranging between 0.07 and 0.30 Bq, measured using a low-background proportional counter. The standard deviation of the automated analytical separation procedure is lower than 3% (n = 10), and the 90Sr isolation process under the studied conditions may be carried out with a yield up to 80%.

  20. A neutron activation analysis procedure for the determination of uranium, thorium and potassium in geologic samples

    USGS Publications Warehouse

    Aruscavage, P. J.; Millard, H.T.

    1972-01-01

    A neutron activation analysis procedure was developed for the determination of uranium, thorium and potassium in basic and ultrabasic rocks. The three elements are determined in the same 0.5-g sample following a 30-min irradiation in a thermal neutron flux of 2??1012 n??cm-2??sec-1. Following radiochemical separation, the nuclides239U (T=23.5 m),233Th (T=22.2 m) and42K (T=12.36 h) are measured by ??-counting. A computer program is used to resolve the decay curves which are complex owing to contamination and the growth of daughter activities. The method was used to determine uranium, throium and potassium in the U. S. Geological Survey standard rocks DTS-1, PCC-1 and BCR-1. For 0.5-g samples the limits of detection for uranium, throium and potassium are 0.7, 1.0 and 10 ppb, respectively. ?? 1972 Akade??miai Kiado??.

  1. Toxin activity assays, devices, methods and systems therefor

    DOEpatents

    Koh, Chung-Yan; Schaff, Ulrich Y.; Sommer, Gregory Jon

    2016-04-05

    Embodiments of the present invention are directed toward devices, system and method for conducting toxin activity assay using sedimentation. The toxin activity assay may include generating complexes which bind to a plurality of beads in a fluid sample. The complexes may include a target toxin and a labeling agent, or may be generated due to presence of active target toxin and/or labeling agent designed to be incorporated into complexes responsive to the presence of target active toxin. The plurality of beads including the complexes may be transported through a density media, wherein the density media has a lower density than a density of the beads and higher than a density of the fluid sample, and wherein the transporting occurs, at least in part, by sedimentation. Signal may be detected from the labeling agents of the complexes.

  2. Quantitative Method of Measuring Metastatic Activity

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  3. Accurate measurement of bromine contents in plastic samples by instrumental neutron activation analysis.

    PubMed

    Kim, I J; Lee, K S; Hwang, E; Min, H S; Yim, Y H

    2013-03-26

    Accurate measurements of bromine contents in plastic samples were made by the direct comparator instrumental neutron activation analysis (INAA). Individual factors affecting the measurements were comprehensively evaluated and compensated, including the volatility loss of bromine from standard comparators, the background bromine level in the filter papers used for preparation of the standard comparators, nuclear interference, γ-ray spectral interference and the variance among replicates of the samples. Uncertainty contributions from those factors were thoroughly evaluated and included in the uncertainty budgeting of the INAA measurement. (81)Br was chosen as the target isotope, and the INAA measurements for bromine were experimentally confirmed to exhibit good linearity within a bromine content range of 10-170 μg. The established method has been applied to the analysis of eight plastic samples: four commercially available certified reference materials (CRMs) of polyethylene and polystyrene and four acrylonitrile butadiene styrene (ABS) samples prepared as the candidate reference materials (KRISS CRM 113-01-012, -013, -014 and -015). The bromine contents of the samples were calculated at three different γ-ray energies and compared, showing good agreement. The results of the four CRMs also showed good consistency with their certified values within the stated uncertainties. Finally, the bromine contents of the ABS samples were determined with expanded uncertainties (at a 95% level of confidence) between 2.5% and 5% in a bromine content range of 25-900 mg kg(-1).

  4. Accurate measurement of bromine contents in plastic samples by instrumental neutron activation analysis.

    PubMed

    Kim, I J; Lee, K S; Hwang, E; Min, H S; Yim, Y H

    2013-03-26

    Accurate measurements of bromine contents in plastic samples were made by the direct comparator instrumental neutron activation analysis (INAA). Individual factors affecting the measurements were comprehensively evaluated and compensated, including the volatility loss of bromine from standard comparators, the background bromine level in the filter papers used for preparation of the standard comparators, nuclear interference, γ-ray spectral interference and the variance among replicates of the samples. Uncertainty contributions from those factors were thoroughly evaluated and included in the uncertainty budgeting of the INAA measurement. (81)Br was chosen as the target isotope, and the INAA measurements for bromine were experimentally confirmed to exhibit good linearity within a bromine content range of 10-170 μg. The established method has been applied to the analysis of eight plastic samples: four commercially available certified reference materials (CRMs) of polyethylene and polystyrene and four acrylonitrile butadiene styrene (ABS) samples prepared as the candidate reference materials (KRISS CRM 113-01-012, -013, -014 and -015). The bromine contents of the samples were calculated at three different γ-ray energies and compared, showing good agreement. The results of the four CRMs also showed good consistency with their certified values within the stated uncertainties. Finally, the bromine contents of the ABS samples were determined with expanded uncertainties (at a 95% level of confidence) between 2.5% and 5% in a bromine content range of 25-900 mg kg(-1). PMID:23498117

  5. A method to optimize sampling locations for measuring indoor air distributions

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Shen, Xiong; Li, Jianmin; Li, Bingye; Duan, Ran; Lin, Chao-Hsin; Liu, Junjie; Chen, Qingyan

    2015-02-01

    Indoor air distributions, such as the distributions of air temperature, air velocity, and contaminant concentrations, are very important to occupants' health and comfort in enclosed spaces. When point data is collected for interpolation to form field distributions, the sampling locations (the locations of the point sensors) have a significant effect on time invested, labor costs and measuring accuracy on field interpolation. This investigation compared two different sampling methods: the grid method and the gradient-based method, for determining sampling locations. The two methods were applied to obtain point air parameter data in an office room and in a section of an economy-class aircraft cabin. The point data obtained was then interpolated to form field distributions by the ordinary Kriging method. Our error analysis shows that the gradient-based sampling method has 32.6% smaller error of interpolation than the grid sampling method. We acquired the function between the interpolation errors and the sampling size (the number of sampling points). According to the function, the sampling size has an optimal value and the maximum sampling size can be determined by the sensor and system errors. This study recommends the gradient-based sampling method for measuring indoor air distributions.

  6. The method of radioactive tracer for measuring the amount of inorganic nanoparticles in biological samples

    NASA Astrophysics Data System (ADS)

    Buzulukov, Yu; Antsiferova, A.; Demin, V. A.; Demin, V. F.; Kashkarov, P.

    2015-11-01

    The method to measure the mass of inorganic nanoparticles in biological (or any other samples) using nanoparticles labeled with radioactive tracers is developed and applied to practice. The tracers are produced in original nanoparticles by radioactive activation of some of their atomic nuclei. The method of radioactive tracers demonstrates a sensitivity, specificity and accuracy equal or better than popular methods of optical and mass spectrometry, or electron microscopy and has some specific advantages. The method can be used for study of absorption, distribution, metabolism and excretion in living organism, as well as in ecological and fundamental research. It was used in practice to study absorption, distribution, metabolism and excretion of nanoparticles of Ag, Au, Se, ZnO, TiO2 as well as to study transportation of silver nanoparticles through the barriers of blood-brain, placenta and milk gland of rats. Brief descriptions of data obtained in experiments with application of this method included in the article. The method was certified in Russian Federation standard system GOST-R and recommended by the Russian Federation regulation authority ROSPOTREBNADZOR for measuring of toxicokinetic and organotropy parameters of nanoparticles.

  7. A zebrafish scale assay to monitor dioxin-like activity in surface water samples.

    PubMed

    Pelayo, Sergi; López-Roldán, Ramón; González, Susana; Casado, Marta; Raldúa, Demetrio; Cortina, Jose Luis; Piña, Benjamin

    2011-10-01

    New regulations on water quality require a close control of the possible biological activities known or unexpected pollutants may bring about. We present here a protocol based on the direct exposure of zebrafish to river water and the analysis of expression of specific genes in their scales to determine the presence of compounds with dioxin-like biological activity. The method does not require the killing of animals and allows detection of the biological activity after a single day of exposure. When tested, the method with real samples from the Llobregat River, clear temporal and spatial variations were observed, demonstrating its suitability for monitoring natural variations in water quality linked to specific discharges. High biological activities were unrelated to the currently checked water quality parameters (macropollutants, turbidity, TOC, etc.), but they did correlate with the presence of micropollutants (estrogens, detergents, etc.) related to domestic and/or industrial runoffs. The scale assay therefore provides a new tool to evaluate water quality changes that cannot be easily derived from the existing standard analytical procedures. It ranks among the very few described protocols able to detect biological effects from natural water samples, without a pre-concentration step, and after only 24 h of exposure. PMID:21822775

  8. Methods for using polypeptides having cellobiohydrolase activity

    DOEpatents

    Morant, Marc D; Harris, Paul

    2016-08-23

    The present invention relates to isolated polypeptides having cellobiohydrolase activity and isolated polynucleotides encoding the polypeptides. The invention also relates to nucleic acid constructs, vectors, and host cells comprising the polynucleotides as well as methods of producing and using the polypeptides.

  9. Sampling uncertainty evaluation for data acquisition board based on Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Ge, Leyi; Wang, Zhongyu

    2008-10-01

    Evaluating the data acquisition board sampling uncertainty is a difficult problem in the field of signal sampling. This paper analyzes the sources of dada acquisition board sampling uncertainty in the first, then introduces a simulation theory of dada acquisition board sampling uncertainty evaluation based on Monte Carlo method and puts forward a relation model of sampling uncertainty results, sampling numbers and simulation times. In the case of different sample numbers and different signal scopes, the author establishes a random sampling uncertainty evaluation program of a PCI-6024E data acquisition board to execute the simulation. The results of the proposed Monte Carlo simulation method are in a good agreement with the GUM ones, and the validities of Monte Carlo method are represented.

  10. [An electrochemical method for measuring metabolic activity and counting cells].

    PubMed

    Kuznetsov, B a; Khlupova, M e; Shleev, S V; Kaprel'iants, A S; Iaropolov, A I

    2006-01-01

    An express electrochemical method for determining the metabolic activity of live cells based on the possibility of an electron exchange between an electrode and elements of the biological electron transfer chain in the presence of a mediator is proposed. This method is useful for studying any live cells (animal, plant, and microbial), including anaerobic, dormant, and spore cells. The sample preparation and measurement itself does not take more than 30 min. The detection limit in a volume of 15 ml amounts to 10-5 cells/ml. The applicability of the assessment method of the metabolic activity level during the transition of the bacteria Mycobacterium smegmatis into an uncultivable dormant state was demonstrated. This method is of special value for medicine and environmental control, detecting latent forms of pathogens. An optimal combination of the methods for the express analysis of latent pathogens is proposed. PMID:17066962

  11. A comparison of swab and maceration methods for bacterial sampling of pig carcasses.

    PubMed Central

    Morgan, I. R.; Krautil, F.; Craven, J. A.

    1985-01-01

    A swabbing technique was compared with an excision and maceration technique for bacteriological sampling of pig carcass skin surfaces. Total viable counts at 37 degrees C obtained by swabbing were 46% of those obtained by maceration. At 21 degrees C, swabbing gave total viable counts which were 54% of the counts obtained from excision samples. Escherichia coli counts showed wide variation with both sampling methods. Neither method was more efficient than the other in recovering E. coli, although excision sampling gave generally higher counts. Both methods were equally effective at recovering salmonellae from carcass surfaces. There was no significant difference between the methods in recovering particular Salmonella serotypes. PMID:3905957

  12. Evaluation of seven aquatic sampling methods for amphibians and other aquatic fauna

    USGS Publications Warehouse

    Gunzburger, M.S.

    2007-01-01

    To design effective and efficient research and monitoring programs researchers must have a thorough understanding of the capabilities and limitations of their sampling methods. Few direct comparative studies exist for aquatic sampling methods for amphibians. The objective of this study was to simultaneously employ seven aquatic sampling methods in 10 wetlands to compare amphibian species richness and number of individuals detected with each method. Four sampling methods allowed counts of individuals (metal dipnet, D-frame dipnet, box trap, crayfish trap), whereas the other three methods allowed detection of species (visual encounter, aural, and froglogger). Amphibian species richness was greatest with froglogger, box trap, and aural samples. For anuran species, the sampling methods by which each life stage was detected was related to relative length of larval and breeding periods and tadpole size. Detection probability of amphibians varied across sampling methods. Box trap sampling resulted in the most precise amphibian count, but the precision of all four count-based methods was low (coefficient of variation > 145 for all methods). The efficacy of the four count sampling methods at sampling fish and aquatic invertebrates was also analyzed because these predatory taxa are known to be important predictors of amphibian habitat distribution. Species richness and counts were similar for fish with the four methods, whereas invertebrate species richness and counts were greatest in box traps. An effective wetland amphibian monitoring program in the southeastern United States should include multiple sampling methods to obtain the most accurate assessment of species community composition at each site. The combined use of frogloggers, crayfish traps, and dipnets may be the most efficient and effective amphibian monitoring protocol. ?? 2007 Brill Academic Publishers.

  13. Measurement for Work. Teaching Guide and Sample Learning Activities.

    ERIC Educational Resources Information Center

    Angel, Margo; Bolton, Chris

    This document is intended to help Australian technical and further education instructors in New South Wales (TAFE NSW) identify teaching principles and learning activities that they can use to help adult learners master the mathematics processes, knowledge, and skills needed to perform basic measurement tasks in today's workplace. The materials…

  14. Simulated Tempering Distributed Replica Sampling, Virtual Replica Exchange, and Other Generalized-Ensemble Methods for Conformational Sampling.

    PubMed

    Rauscher, Sarah; Neale, Chris; Pomès, Régis

    2009-10-13

    Generalized-ensemble algorithms in temperature space have become popular tools to enhance conformational sampling in biomolecular simulations. A random walk in temperature leads to a corresponding random walk in potential energy, which can be used to cross over energetic barriers and overcome the problem of quasi-nonergodicity. In this paper, we introduce two novel methods: simulated tempering distributed replica sampling (STDR) and virtual replica exchange (VREX). These methods are designed to address the practical issues inherent in the replica exchange (RE), simulated tempering (ST), and serial replica exchange (SREM) algorithms. RE requires a large, dedicated, and homogeneous cluster of CPUs to function efficiently when applied to complex systems. ST and SREM both have the drawback of requiring extensive initial simulations, possibly adaptive, for the calculation of weight factors or potential energy distribution functions. STDR and VREX alleviate the need for lengthy initial simulations, and for synchronization and extensive communication between replicas. Both methods are therefore suitable for distributed or heterogeneous computing platforms. We perform an objective comparison of all five algorithms in terms of both implementation issues and sampling efficiency. We use disordered peptides in explicit water as test systems, for a total simulation time of over 42 μs. Efficiency is defined in terms of both structural convergence and temperature diffusion, and we show that these definitions of efficiency are in fact correlated. Importantly, we find that ST-based methods exhibit faster temperature diffusion and correspondingly faster convergence of structural properties compared to RE-based methods. Within the RE-based methods, VREX is superior to both SREM and RE. On the basis of our observations, we conclude that ST is ideal for simple systems, while STDR is well-suited for complex systems.

  15. Development of a sampling and analytical method for 2,2-dichloro-1,1,1-trifluoroethane in workplace air.

    PubMed

    Shin, Yong Chul; Yi, Gwang Yong; Kim, Yangho; Paik, Nam Won

    2002-01-01

    The use of 2,2-dichloro-1,1,1-trifluoroethane (compound number: HCFC-123) is growing in industry as a substitute for ozone-depleting chlorofluorocarbons (CFCs). Recently, liver-related illnesses have been reported from industries handling HCFC-123. However, information on worker exposure to the material is limited, and an acceptable sampling/analytical method is not available. The aim of this study was to develop a widely applicable sampling and analytical method to determine worker exposures to airborne HCFC-123 and to evaluate the performance of the method. A solid sorbent tube, containing two sections (400 mg in the front and 200 mg in the back) of activated coconut-shell charcoal was chosen for sampling airborne HCFC-123 vapor. The breakthrough volumes were 13.6 L at 3597 +/- 210.1 ppm (with a sampling airflow rate of 0.046 L/min) and 17.0 L at 1841 +/- 4.5 ppm (with sampling airflow rate of 0.046-0.050 L/min). Samples of HCFC-123 in the charcoal tube were stable for 7 days either at room temperature or in a refrigerator and a migration occurred within 14 days at room temperature. It is recommended that the HCFC-123 sample in activated charcoal tubes be stored either at room temperature or in a refrigerator and be analyzed within 7 days. The HCFC-123 in the charcoal tubes was desorbed into dichloromethane and analyzed using gas chromatography/ flame ionization detection. The limit of detection was 0.23 mg/sample, and the average desorption efficiency was 99.0%. The total coefficient of variation was 0.060, and the method accuracy was 16.6%. In conclusion, the performance of the sampling and analytical method developed for the determination of airborne HCFC-123 concentrations was acceptable to the NIOSH sampling and analytical criteria. PMID:12570079

  16. A Novel Method of Failure Sample Selection for Electrical Systems Using Ant Colony Optimization

    PubMed Central

    Tian, Shulin; Yang, Chenglin; Liu, Cheng

    2016-01-01

    The influence of failure propagation is ignored in failure sample selection based on traditional testability demonstration experiment method. Traditional failure sample selection generally causes the omission of some failures during the selection and this phenomenon could lead to some fearful risks of usage because these failures will lead to serious propagation failures. This paper proposes a new failure sample selection method to solve the problem. First, the method uses a directed graph and ant colony optimization (ACO) to obtain a subsequent failure propagation set (SFPS) based on failure propagation model and then we propose a new failure sample selection method on the basis of the number of SFPS. Compared with traditional sampling plan, this method is able to improve the coverage of testing failure samples, increase the capacity of diagnosis, and decrease the risk of using. PMID:27738424

  17. Method for monitoring stack gases for uranium activity

    DOEpatents

    Beverly, Claude R.; Ernstberger, Harold G.

    1988-01-01

    A method for monitoring the stack gases of a purge cascade of a gaseous diffusion plant for uranium activity. A sample stream is taken from the stack gases and contacted with a volume of moisture-laden air for converting trace levels of uranium hexafluoride, if any, in the stack gases into particulate uranyl fluoride. A continuous strip of filter paper from a supply roll is passed through this sampling stream to intercept and gather any uranyl fluoride in the sampling stream. This filter paper is then passed by an alpha scintillation counting device where any radioactivity on the filter paper is sensed so as to provide a continuous monitoring of the gas stream for activity indicative of the uranium content in the stack gases.

  18. Method for monitoring stack gases for uranium activity

    DOEpatents

    Beverly, C.R.; Ernstberger, E.G.

    1985-07-03

    A method for monitoring the stack gases of a purge cascade of gaseous diffusion plant for uranium activity. A sample stream is taken from the stack gases and contacted with a volume of moisture-laden air for converting trace levels of uranium hexafluoride, if any, in the stack gases into particulate uranyl fluoride. A continuous strip of filter paper from a supply roll is passed through this sampling stream to intercept and gather any uranyl fluoride in the sampling stream. This filter paper is then passed by an alpha scintillation counting device where any radioactivity on the filter paper is sensed so as to provide a continuous monitoring of the gas stream for activity indicative of the uranium content in the stack gases. 1 fig.

  19. Evaluation of methods to assess physical activity

    NASA Astrophysics Data System (ADS)

    Leenders, Nicole Y. J. M.

    Epidemiological evidence has accumulated that demonstrates that the amount of physical activity-related energy expenditure during a week reduces the incidence of cardiovascular disease, diabetes, obesity, and all-cause mortality. To further understand the amount of daily physical activity and related energy expenditure that are necessary to maintain or improve the functional health status and quality of life, instruments that estimate total (TDEE) and physical activity-related energy expenditure (PAEE) under free-living conditions should be determined to be valid and reliable. Without evaluation of the various methods that estimate TDEE and PAEE with the doubly labeled water (DLW) method in females there will be eventual significant limitations on assessing the efficacy of physical activity interventions on health status in this population. A triaxial accelerometer (Tritrac-R3D, (TT)), an uniaxial (Computer Science and Applications Inc., (CSA)) activity monitor, a Yamax-Digiwalker-500sp°ler , (YX-stepcounter), by measuring heart rate responses (HR method) and a 7-d Physical Activity Recall questionnaire (7-d PAR) were compared with the "criterion method" of DLW during a 7-d period in female adults. The DLW-TDEE was underestimated on average 9, 11 and 15% using 7-d PAR, HR method and TT. The underestimation of DLW-PAEE by 7-d PAR was 21% compared to 47% and 67% for TT and YX-stepcounter. Approximately 56% of the variance in DLW-PAEE*kgsp{-1} is explained by the registration of body movement with accelerometry. A larger proportion of the variance in DLW-PAEE*kgsp{-1} was explained by jointly incorporating information from the vertical and horizontal movement measured with the CSA and Tritrac-R3D (rsp2 = 0.87). Although only a small amount of variance in DLW-PAEE*kgsp{-1} is explained by the number of steps taken per day, because of its low cost and ease of use, the Yamax-stepcounter is useful in studies promoting daily walking. Thus, studies involving the

  20. A comparative study between the dynamic method and passive can technique of radon exhalation measurements from samples.

    PubMed

    Raj Menon, Sreeja; Sahoo, B K; Balasundar, S; Gaware, J J; Jose, M T; Venkatraman, B; Mayya, Y S

    2015-05-01

    A comparative study has been carried out between the SSNTD based 'can' technique and active monitors based dynamic method using nine different samples, eight of granite and one of phosphogypsum. Besides radon ((222)Rn) exhalation, thoron((220)Rn) exhalation and (226)Ra and (232)Th content were also measured. The results are: (i) presence of significant thoron exhalation from samples and (ii) observation of thoron interference and leak (~0.05h(-1)) from the 'can' in the SSNTD based 'can' technqiue. The study unequivocally demonstrates the presence of intrinsic uncertainty in SSNTD based 'can' technique. Instead, dynamic method offers a more reliable and faster method. PMID:25770859

  1. A comparative study between the dynamic method and passive can technique of radon exhalation measurements from samples.

    PubMed

    Raj Menon, Sreeja; Sahoo, B K; Balasundar, S; Gaware, J J; Jose, M T; Venkatraman, B; Mayya, Y S

    2015-05-01

    A comparative study has been carried out between the SSNTD based 'can' technique and active monitors based dynamic method using nine different samples, eight of granite and one of phosphogypsum. Besides radon ((222)Rn) exhalation, thoron((220)Rn) exhalation and (226)Ra and (232)Th content were also measured. The results are: (i) presence of significant thoron exhalation from samples and (ii) observation of thoron interference and leak (~0.05h(-1)) from the 'can' in the SSNTD based 'can' technqiue. The study unequivocally demonstrates the presence of intrinsic uncertainty in SSNTD based 'can' technique. Instead, dynamic method offers a more reliable and faster method.

  2. In vitro antimicrobial activity of propolis samples from different geographical origins against certain oral pathogens.

    PubMed

    Koru, Ozgur; Toksoy, Fulya; Acikel, Cengiz Han; Tunca, Yasar Meric; Baysallar, Mehmet; Uskudar Guclu, Aylin; Akca, Eralp; Ozkok Tuylu, Asli; Sorkun, Kadriye; Tanyuksel, Mehmet; Salih, Bekir

    2007-01-01

    Propolis is an agent having antimicrobial properties, however, its composition can vary depending on the area where it is collected. In the present study, the antimicrobial activity of five propolis samples, collected from four different regions in Turkey and from Brazil, against nine anaerobic strains was evaluated. Ethanol extracts of propolis (EEP) were prepared from propolis samples and we determined minimum inhibitory concentrations (MIC) and minimum bactericidal concentrations (MBC) of EEP on the growth of test microorganisms by using agar dilution method. All strains were susceptible and MIC values ranged from 4 to 512 microg/ml for propolis activity. Propolis from Kazan-Ankara showed most effective MIC values to the studied microorganisms. MBC values of Kazan-Ankara EEP samples were ranged from 8 to 512 microg/ml. Death was observed within 4 h of incubation for Peptostreptococcus anaerobius and micros and Lactobacillus acidophilus and Actinomyces naeslundii, while 8 h for Prevotella oralis and Prevotella melaninogenica and Porphyromonas gingivalis, 12 h for Fusobacterium nucleatum, 16 h for Veillonella parvula. It was shown that propolis samples were more effective against Gram positive anaerobic bacteria than Gram negative ones. The organic chemical compositions of EEPs were determined by high-resolution gas chromatography coupled to mass spectrometry (GC-MS). The main compounds of EEPs were flavonoids such as pinobanksin, quercetin, naringenin, galangine, chrysin and aromatic acids such as cafeic acid. Because of increased antimicrobial resistance, propolis may be kept in mind in the treatment of oral cavity diseases.

  3. [Study on a method of selecting calibration samples in NIR spectral analysis].

    PubMed

    Qin, Chong; Chen, Wen-Wen; He, Xiong-Kui; Zhang, Lu-Da; Ma, Xiang

    2009-10-01

    In the present paper, a simple but novel method based on maximum linearly independent group was introduced into near-infrared (NIR) spectral analysis for selecting representative calibration samples. The experiment materials contained 2,652 tobacco powder samples, with 1,001 samples randomly selected as prediction set, and the others as representative sample candidate set from which calibration sample set was selected. The method of locating maximum linearly independent vectors was used to select representative samples from the spectral vectors of representative samples candidate set. The arithmetic was accomplished by function rref(X,q) in Matlab. The maximum linearly independent spectral vectors were treated as calibration samples set. When different calculating precision q was given, different amount of representative samples were acquired. The selected calibration sample set was used to build regression model to predict the total sugar of tobacco powder samples by PLS. The model was used to analyze 1001 samples in the prediction set. When selecting 32 representative samples, the model presented a good predictive veracity, whose predictive mean relative error was 3.6210%, and correlation coefficient was 0.9643. By paired-samples t-test, we found that the difference between the predicting result of model obtained by 32 samples and that obtained by 146 samples was not significant (alpha=0.05). Also, we compared the methods of randomly selecting calibration samples and maximum linearly independent selection by their predicting effects of models. In the experiment, correspondingly, six calibration sample sets were selected, one of which included 28 samples, while the others included 32, 41, 76, 146 and 163 samples respectively. The method of maximum linearly independent selecting samples turned out to be obviously better than that of randomly selecting. The result indicated that the proposed method can not only effectively enhance the cost-effectiveness of NIR

  4. METHOD DEVELOPMENT FOR THE DETERMINATION OF FORMALDEHYDE IN SAMPLES OF ENVIRONMENTAL ORIGIN

    EPA Science Inventory

    An analytical method was developed for the determination of formaldehyde in samples of environmental origin. After a review of the current literature, five candidate methods involving chemical derivatization were chosen for evaluation. The five derivatization reagents studied wer...

  5. Practical method for extraction of PCR-quality DNA from environmental soil samples.

    PubMed

    Fitzpatrick, Kelly A; Kersh, Gilbert J; Massung, Robert F

    2010-07-01

    Methods for the extraction of PCR-quality DNA from environmental soil samples by using pairs of commercially available kits were evaluated. Coxiella burnetii DNA was detected in spiked soil samples at <1,000 genome equivalents per gram of soil and in 12 (16.4%) of 73 environmental soil samples.

  6. Sample Heat, Activity, Reactivity, and Dose Analysis for Safety Analysis of Irradiations in a Research Reactor.

    1987-12-01

    SHARDA is a program for assessing sample heating rates, activities produced and reactivity load caused while irradiating a small sample in a well thermalized research reactor like CIRUS. It estimates the sample cooling or lead shielding requirements to limit the gamma-ray dose rates due to the irradiated sample within permissible levels.

  7. A robust adaptive sampling method for faster acquisition of MR images.

    PubMed

    Vellagoundar, Jaganathan; Machireddy, Ramasubba Reddy

    2015-06-01

    A robust adaptive k-space sampling method is proposed for faster acquisition and reconstruction of MR images. In this method, undersampling patterns are generated based on magnitude profile of a fully acquired 2-D k-space data. Images are reconstructed using compressive sampling reconstruction algorithm. Simulation experiments are done to assess the performance of the proposed method under various signal-to-noise ratio (SNR) levels. The performance of the method is better than non-adaptive variable density sampling method when k-space SNR is greater than 10dB. The method is implemented on a fully acquired multi-slice raw k-space data and a quality assurance phantom data. Data reduction of up to 60% is achieved in the multi-slice imaging data and 75% is achieved in the phantom imaging data. The results show that reconstruction accuracy is improved over non-adaptive or conventional variable density sampling method. The proposed sampling method is signal dependent and the estimation of sampling locations is robust to noise. As a result, it eliminates the necessity of mathematical model and parameter tuning to compute k-space sampling patterns as required in non-adaptive sampling methods.

  8. Active music therapy and Parkinson's disease: methods.

    PubMed

    Pacchetti, C; Aglieri, R; Mancini, F; Martignoni, E; Nappi, G

    1998-01-01

    Music therapy (MT) is an unconventional, multisensorial therapy poorly assessed in medical care but widely used to different ends in a variety of settings. MT has two branches: active and passive. In active MT the utilisation of instruments is structured to correspond to all sensory organs so as to obtain suitable motor and emotional responses. We conducted a prospective study to evaluate the effects of MT in the neurorehabilitation of patients with Parkinson's Disease (PD), a common degenerative disorder involving movement and emotional impairment. Sixteen PD patients took part in 13 weekly sessions of MT each lasting 2 hours. At the beginning and at the end of the session, every 2 weeks, the patients were evaluated by a neurologist, who assessed PD severity with UPDRS, emotional functions with Happiness Measures (HM) and quality of life using the Parkinson's Disease Quality of Life Questionnaire (PDQL). After every session a significant improvement in motor function, particularly in relation to hypokinesia, was observed both in the overall and in the pre-post session evaluations. HM, UPDRS-ADL and PDQL changes confirmed an improving effect of MT on emotional functions, activities of daily living and quality of life. In conclusion, active MT, operating at a multisensorial level, stimulates motor, affective and behavioural functions. Finally, we propose active MT as new method to include in PD rehabilitation programmes. This article describes the methods adopted during MT sessions with PD patients. PMID:9584875

  9. Systems and methods for separating particles and/or substances from a sample fluid

    DOEpatents

    Mariella, Jr., Raymond P.; Dougherty, George M.; Dzenitis, John M.; Miles, Robin R.; Clague, David S.

    2016-11-01

    Systems and methods for separating particles and/or toxins from a sample fluid. A method according to one embodiment comprises simultaneously passing a sample fluid and a buffer fluid through a chamber such that a fluidic interface is formed between the sample fluid and the buffer fluid as the fluids pass through the chamber, the sample fluid having particles of interest therein; applying a force to the fluids for urging the particles of interest to pass through the interface into the buffer fluid; and substantially separating the buffer fluid from the sample fluid.

  10. Persistence Pays Off: Follow-Up Methods for Difficult-to-Track Longitudinal Samples*

    PubMed Central

    Kleschinsky, John H.; Bosworth, Leslie B.; Nelson, Sarah E.; Walsh, Erinn K.; Shaffer, Howard J.

    2009-01-01

    Objective: Evolving privacy and confidentiality regulations make achieving high completion rates in longitudinal studies challenging. Periodically reviewing the methods researchers use to retain participants throughout the follow-up period is important. We review the effectiveness of methods to maximize completion rates in a 1-year longitudinal study of repeat driving-under-the-influence (DUI) offenders. Method: During the course of 21 months, we attempted to follow-up with 704 participants of a licensed residential treatment facility for repeat DUI offenders. High rates of lifetime Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, substance-use disorders (97.6%) and nonsubstance- or nongambling-related psychiatric disorders (44.5%) among the sample made tracking participants difficult. To locate participants and complete follow-up interviews, we obtained baseline information, contacted collaterals, sent mailed reminders, searched Internet databases, and gave a monetary incentive for completing study interviews. Results: We located 608 participants with active telephone numbers (87.4%) and completed interviews with 488 (70.1% of the entire eligible sample and 80.3% of those with active telephone numbers), after an average (SD) of 8.6 (9.1) calls (median = 5.0). Increasing the number of calls continued to yield additional completions at 10, 20, and 30 calls; at approximately 40 telephone calls, the potential return for additional calls did not justify the added effort. Conclusions: These results suggest that researchers need to (1) employ more than 10 telephone calls to adequately track difficult-to-follow substance-using populations, and (2) prepare for a subsample of participants who might require more extensive contact. These results highlight the importance of using empirical guidelines to plan estimates for the number of contacts needed to achieve an adequate follow-up completion rate. PMID:19737500

  11. The impact of particle size selective sampling methods on occupational assessment of airborne beryllium particulates.

    PubMed

    Sleeth, Darrah K

    2013-05-01

    In 2010, the American Conference of Governmental Industrial Hygienists (ACGIH) formally changed its Threshold Limit Value (TLV) for beryllium from a 'total' particulate sample to an inhalable particulate sample. This change may have important implications for workplace air sampling of beryllium. A history of particle size-selective sampling methods, with a special focus on beryllium, will be provided. The current state of the science on inhalable sampling will also be presented, including a look to the future at what new methods or technology may be on the horizon. This includes new sampling criteria focused on particle deposition in the lung, proposed changes to the existing inhalable convention, as well as how the issues facing beryllium sampling may help drive other changes in sampling technology.

  12. Total nitrogen determination of various sample types: a comparison of the Hach, Kjeltec, and Kjeldahl methods.

    PubMed

    Watkins, K L; Veum, T L; Krause, G F

    1987-01-01

    Conventional Kjeldahl analysis with modifications, Kjeltec analysis with block digestion and semiautomated distillation, and the Hach method for determining nitrogen (N) were compared using a wide range of samples. Twenty different sample types were ground and mixed. Each sample type was divided into 5 subsamples which were analyzed for N by each of the 3 methods. In each sample type, differences (P less than 0.05) were detected among the 3 N determination methods in 5 of the 20 N sources analyzed. The mean N content over all 20 samples was higher with Kjeldahl analysis (P less than 0.05) than with Kjeltec, while Hach analysis produced intermediate results. Results also indicated that the Hach procedure had the greatest ability to detect differences in N content among sample types, being more sensitive than either other method (P less than 0.05).

  13. Improved Butanol-Methanol (BUME) Method by Replacing Acetic Acid for Lipid Extraction of Biological Samples.

    PubMed

    Cruz, Mutya; Wang, Miao; Frisch-Daiello, Jessica; Han, Xianlin

    2016-07-01

    Extraction of lipids from biological samples is a critical step in lipidomics, especially for shotgun lipidomics where lipid extracts are directly infused into a mass spectrometer. The butanol-methanol (BUME) extraction method was originally developed to extract lipids from plasma samples with 1 % acetic acid. Considering some lipids are sensitive to acidic environments, we modified this protocol by replacing acetic acid with lithium chloride solution and extended the modified extraction to tissue samples. Although no significant reduction of plasmalogen levels in the acidic BUME extracts of rat heart samples was found, the modified method was established to extract various tissue samples, including rat liver, heart, and plasma. Essentially identical profiles of the majority of lipid classes were obtained from the extracts of the modified BUME and traditional Bligh-Dyer methods. However, it was found that neither the original, nor the modified BUME method was suitable for 4-hydroxyalkenal species measurement in biological samples. PMID:27245345

  14. Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian K.; Warren, Richard A.; McAlister, Daniel R.

    2016-03-24

    A new method that rapidly preconcentrates and measures 226Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226Ra sample preparation takes < 2 hours.

  15. Optical method for the characterization of laterally-patterned samples in integrated circuits

    DOEpatents

    Maris, Humphrey J.

    2001-01-01

    Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

  16. A LITERATURE REVIEW OF WIPE SAMPLING METHODS FOR CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

    EPA Science Inventory

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerous

    methods of wipe sampling exist, and each method has its own specification for the type of wipe, we...

  17. Sampling Methods and the Accredited Population in Athletic Training Education Research

    ERIC Educational Resources Information Center

    Carr, W. David; Volberding, Jennifer

    2009-01-01

    Context: We describe methods of sampling the widely-studied, yet poorly defined, population of accredited athletic training education programs (ATEPs). Objective: There are two purposes to this study; first to describe the incidence and types of sampling methods used in athletic training education research, and second to clearly define the…

  18. 7 CFR 51.308 - Methods of sampling and calculation of percentages.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Grades of Apples Methods of Sampling and Calculation of Percentages § 51.308 Methods of sampling and... weigh ten pounds or less, or in any container where the minimum diameter of the smallest apple does not vary more than 1/2 inch from the minimum diameter of the largest apple, percentages shall be...

  19. 7 CFR 51.308 - Methods of sampling and calculation of percentages.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Grades of Apples Methods of Sampling and Calculation of Percentages § 51.308 Methods of sampling and... weigh ten pounds or less, or in any container where the minimum diameter of the smallest apple does not vary more than 1/2 inch from the minimum diameter of the largest apple, percentages shall be...

  20. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from the American... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Sampling methods for gasoline and... gasoline and diesel fuel. The sampling methods specified in this section shall be used to collect...

  1. 40 CFR 80.8 - Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of the Federal Register under 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Sampling methods for gasoline, diesel... Provisions § 80.8 Sampling methods for gasoline, diesel fuel, fuel additives, and renewable fuels....

  2. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from the American... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Sampling methods for gasoline and... gasoline and diesel fuel. The sampling methods specified in this section shall be used to collect...

  3. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from the American... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Sampling methods for gasoline and... gasoline and diesel fuel. The sampling methods specified in this section shall be used to collect...

  4. Evaluation of beef trim sampling methods for detection of Shiga toxin-producing Escherichia coli (STEC)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Presence of Shiga toxin-producing Escherichia coli (STEC) is a major concern in ground beef. Several methods for sampling beef trim prior to grinding are currently used in the beef industry. The purpose of this study was to determine the efficacy of the sampling methods for detecting STEC in beef ...

  5. Application of a Permethrin Immunosorbent Assay Method to Residential Soil and Dust Samples

    EPA Science Inventory

    A low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:wate...

  6. THE INFLUENCE OF PHYSICAL FACTORS ON COMPARATIVE PERFORMANCE OF SAMPLING METHODS IN LARGE RIVERS

    EPA Science Inventory

    In 1999, we compared five existing benthic macroinvertebrate sampling methods used in boatable rivers. Each sampling protocol was performed at each of 60 sites distributed among four rivers in the Ohio River drainage basin. Initial comparison of methods using key macroinvertebr...

  7. Viability of Actinobacillus pleuropneumoniae in frozen pig lung samples and comparison of different methods of direct diagnosis in fresh samples.

    PubMed

    Gutierrez, C B; Rodriguez Barbosa, J I; Gonzalez, O R; Tascon, R I; Rodriguez Ferri, E F

    1992-04-01

    A comparative study on different methods of diagnosis of Actinobacillus pleuropneumoniae from both fresh and frozen pig lungs is described. A total of 196 lung tissues with pneumonic lesions were examined for culture isolation on chocolate blood agar, as well as for antigen detection by means of the coagglutination test, the immunodiffusion test and the indirect ELISA. These samples were subsequently frozen for 1 yr and then they were recultured. A. pleuropneumoniae was recovered from fresh lung specimens in 30 cases (15.3%) and from frozen samples in only two cases (0.9%). Such a different degree of isolation demonstrates that long freezing had an adverse effect on the viability of this organism in lung samples. A pleuropneumoniae detection was positive in 134 samples (68.4%) by at least one of the immunological techniques examined. The indirect ELISA was the most sensitive and specific test, with antigen detected in 125 lungs (63.8%). In comparison with the coagglutination and immunodiffusion tests, the sensitivities of the indirect ELISA were 95.8 and 93.7%, and the specificities were 67.0 and 63.4%, respectively.

  8. Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Cappelletti, C. A.; Mendonca, F. J.; Lee, D. C. L.; Shimabukuro, Y. E.

    1982-01-01

    A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

  9. Quantitative method of determining beryllium or a compound thereof in a sample

    DOEpatents

    McCleskey, T. Mark; Ehler, Deborah S.; John, Kevin D.; Burrell, Anthony K.; Collis, Gavin E.; Minogue, Edel M.; Warner, Benjamin P.

    2010-08-24

    A method of determining beryllium or a beryllium compound thereof in a sample, includes providing a sample suspected of comprising beryllium or a compound thereof, extracting beryllium or a compound thereof from the sample by dissolving in a solution, adding a fluorescent indicator to the solution to thereby bind any beryllium or a compound thereof to the fluorescent indicator, and determining the presence or amount of any beryllium or a compound thereof in the sample by measuring fluorescence.

  10. Quantitative method of determining beryllium or a compound thereof in a sample

    DOEpatents

    McCleskey, T. Mark; Ehler, Deborah S.; John, Kevin D.; Burrell, Anthony K.; Collis, Gavin E.; Minogue, Edel M.; Warner, Benjamin P.

    2006-10-31

    A method of determining beryllium or a beryllium compound thereof in a sample, includes providing a sample suspected of comprising beryllium or a compound thereof, extracting beryllium or a compound thereof from the sample by dissolving in a solution, adding a fluorescent indicator to the solution to thereby bind any beryllium or a compound thereof to the fluorescent indicator, and determining the presence or amount of any beryllium or a compound thereof in the sample by measuring fluorescence.

  11. Map showing locations of samples dated by radiocarbon methods in the San Francisco Bay region

    USGS Publications Warehouse

    Wright, Robert H.

    1971-01-01

    The potential value of a radiocarbon date is diminished, however, if adequate site data are not taken with the sample and do not accompany the date in publication.  At a minimum, published dates should include an accurate location for the dated sample, type of material dated and method of dating, nature of the site, depth below surface (or other accurately defined datum) of date sample, stratigraphy of material overlying date sample, and the significance of the data in the study.

  12. Using activated attapulgite as sorbent for solid-phase extraction of melamine in milk formula samples.

    PubMed

    Wang, Ting-Ting; Xuan, Rong-Rong; Ma, Jun-Feng; Tan, Yao; Jin, Zhen-Feng; Chen, Yi-Hui; Zhang, Li-Hua; Zhang, Yu-Kui

    2016-09-01

    In this study, a simple solid-phase extraction (SPE) approach by using activated attapulgite as sorbent was successfully developed for the determination of melamine in milk formula samples. Crucial factors impacting the extraction efficiency, including sample solvent, elution solvent, and sample loading volume, were investigated. Under the optimal extraction conditions, the sample loading volume was up to 200 mL and the adsorption capacity of the melamine gave rise to 1154 μg g(-1). Excellent linear calibration curves (r (2)  > 0.999) were achieved, and then the limit of detection (S/N = 3) and the limit of quantification (S/N = 10) were found to be 0.15 and 0.5 ng mL(-1), respectively. The recoveries of the melamine spiked in four milk formula samples at three concentration levels ranged from 83.5 to 111.0 % with relative standard deviations (RSDs) less than 10.2 %. Furthermore, RSDs of batch to batch (n = 4) of the acidified attapulgite used in this developed method were in the range of 2.3∼7.3 %. In comparison to the commercial Oasis MCX, the acidified attapulgite sorbent even outperformed (at least in terms of reproducibility) for melamine analysis in real food samples. Because of its simplicity, the newly developed SPE method based on acidified attapulgite nanoparticles should provide a promising tool for daily monitoring of doped melamine in milk formula or other complex matrices. PMID:27430500

  13. Universal nucleic acids sample preparation method for cells, spores and their mixture

    DOEpatents

    Bavykin, Sergei

    2011-01-18

    The present invention relates to a method for extracting nucleic acids from biological samples. More specifically the invention relates to a universal method for extracting nucleic acids from unidentified biological samples. An advantage of the presently invented method is its ability to effectively and efficiently extract nucleic acids from a variety of different cell types including but not limited to prokaryotic or eukaryotic cells and/or recalcitrant organisms (i.e. spores). Unlike prior art methods which are focused on extracting nucleic acids from vegetative cell or spores, the present invention effectively extracts nucleic acids from spores, multiple cell types or mixtures thereof using a single method. Important that the invented method has demonstrated an ability to extract nucleic acids from spores and vegetative bacterial cells with similar levels effectiveness. The invented method employs a multi-step protocol which erodes the cell structure of the biological sample, isolates, labels, fragments nucleic acids and purifies labeled samples from the excess of dye.

  14. COMPARISON OF SAMPLING METHODS FOR SEMI-VOLATILE ORGANIC CARBON (SVOC) ASSOCIATED WITH PM 2.5

    EPA Science Inventory

    This study evaluates the influence of denuder sampling methods and filter collection media on the measurement of semi-volatile organic carbon (SVOC) associated with PM2.5. Two types of collection media, charcoal (activated carbon) and XAD, were used both in diffusion denuders ...

  15. Specific activity and hazards of granite samples collected from the Eastern Desert of Egypt.

    PubMed

    Arafa, Wafaa

    2004-01-01

    Fifty granitic rock samples were collected from different plutons in the central part of the Eastern Desert of Egypt and were analyzed for specific concentrations of (238)U, (232)Th and (40)K radionuclei. The measurements were carried out using a high performance and stability Nomad Plus spectroscopy system attached to a 1.7 keV (FWHM) HPGe detector. The spectra were analyzed using the direct gamma counting comparison method as well as the traditional absolute efficiency curve method. The highest average value of (238)U concentration (1184 Bq kg(-1)) was observed at EI Misikat region whereas the highest average values of (40)K and (232)Th concentration (2301.8 and 162.5 Bq kg(-1) respectively), were detected at Gabal Homret Waggat area. The radium equivalent activity (Ra(eq)), the absorbed dose rate (D), the external hazard index (H(ex)) and the annual gonadal dose equivalent were also calculated and compared to the international recommended values. Radon exhalation rate from the rock samples were measured using the activated charcoal canister method. The average value of radon exhalation varies from 0.052 to 0.69 Bq m(-2) h(-1) and depends on the specific concentration of uranium.

  16. Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

    USGS Publications Warehouse

    Millard, H.T.

    1987-01-01

    Low-level methods for the determination of iridium and other noble metals have become increasingly important in recent years due to interest in locating abundance anomalies associated with the Cretaceous and Tertiary (K-T) boundary. Typical iridium anomalies are in the range of 1 to 100 ??g/kg (ppb). Thus methods with detection limits near 0.1 ??g/kg should be adequate to detect K-T boundary anomalies. Radiochemical neutron activation analysis methods continue to be required although instrumental neutron activation analysis techniques employing elaborate gamma-counters are under development. In the procedure developed in this study samples irradiated in the epithermal neutron facility of the U. S. Geological Survey TRIGA Reactor (Denver, Colorado) are treated with a mini-fire assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium perioxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure has been applied to the U.S.G.S. Standard Rock PCC-1 and samples from K-T boundary sites in the Western Interior of North America. ?? 1987 Akade??miai Kiado??.

  17. Method for photon activation positron annihilation analysis

    DOEpatents

    Akers, Douglas W.

    2006-06-06

    A non-destructive testing method comprises providing a specimen having at least one positron emitter therein; determining a threshold energy for activating the positron emitter; and determining whether a half-life of the positron emitter is less than a selected half-life. If the half-life of the positron emitter is greater than or equal to the selected half-life, then activating the positron emitter by bombarding the specimen with photons having energies greater than the threshold energy and detecting gamma rays produced by annihilation of positrons in the specimen. If the half-life of the positron emitter is less then the selected half-life, then alternately activating the positron emitter by bombarding the specimen with photons having energies greater then the threshold energy and detecting gamma rays produced by positron annihilation within the specimen.

  18. [Establishment and assessment of QA/QC method for sampling and analysis of atmosphere background CO2].

    PubMed

    Liu, Li-xin; Zhou, Ling-xi; Xia, Ling-jun; Wang, Hong-yang; Fang, Shuang-xi

    2014-12-01

    To strengthen scientific management and sharing of greenhouse gas data obtained from atmospheric background stations in China, it is important to ensure the standardization of quality assurance and quality control method for background CO2 sampling and analysis. Based on the greenhouse gas sampling and observation experience of CMA, using portable sampling observation and WS-CRDS analysis technique as an example, the quality assurance measures for atmospheric CO,sampling and observation in the Waliguan station (Qinghai), the glass bottle quality assurance measures and the systematic quality control method during sample analysis, the correction method during data processing, as well as the data grading quality markers and data fitting interpolation method were systematically introduced. Finally, using this research method, the CO2 sampling and observation data at the atmospheric background stations in 3 typical regions were processed and the concentration variation characteristics were analyzed, indicating that this research method could well catch the influences of the regional and local environmental factors on the observation results, and reflect the characteristics of natural and human activities in an objective and accurate way.

  19. [Preparation of sub-standard samples and XRF analytical method of powder non-metallic minerals].

    PubMed

    Kong, Qin; Chen, Lei; Wang, Ling

    2012-05-01

    In order to solve the problem that standard samples of non-metallic minerals are not satisfactory in practical work by X-ray fluorescence spectrometer (XRF) analysis with pressed powder pellet, a method was studied how to make sub-standard samples according to standard samples of non-metallic minerals and to determine how they can adapt to analysis of mineral powder samples, taking the K-feldspar ore in Ebian-Wudu, Sichuan as an example. Based on the characteristic analysis of K-feldspar ore and the standard samples by X-ray diffraction (XRD) and chemical methods, combined with the principle of the same or similar between the sub-standard samples and unknown samples, the experiment developed the method of preparation of sub-standard samples: both of the two samples above mentioned should have the same kind of minerals and the similar chemical components, adapt mineral processing, and benefit making working curve. Under the optimum experimental conditions, a method for determination of SiO2, Al2O3, Fe2O3, TiO2, CaO, MgO, K2O and Na2O of K-feldspar ore by XRF was established. Thedetermination results are in good agreement with classical chemical methods, which indicates that this method was accurate.

  20. Phosphatase activity in Antarctica soil samples as a biosignature of extant life

    NASA Astrophysics Data System (ADS)

    Sato, Shuji; Itoh, Yuki; Takano, Yoshinori; Fukui, Manabu; Kaneko, Takeo; Kobayashi, Kensei

    Microbial activities have been detected in such extreme terrestrial environments as deep lithosphere, a submarine hydrothermal systems, stratosphere, and Antarctica. Microorganisms have adapted to such harsh environments by evolving their biomolecules. Some of these biomolecules such as enzymes might have different characteristics from those of organisms in ordinary environments. Many biosignatures (or biomarkers) have been proposed to detect microbial activities in such extreme environments. A number of techniques are proposed to evaluate biological activities in extreme environments including cultivation methods, assay of metabolism, and analysis of bioorganic compounds like amino acids and DNA. Enzyme activities are useful signature of extant life in extreme environments. Among many enzymes, phosphatase could be a good indicator of biological activities, since phosphate esters are essential for all the living terrestrial organisms. In addition, alkaline phosphatase is known as a typical zinc-containing metalloenzyme and quite stable in environments. We analyzed phosphatase activities in Antarctica soil samples to see whether they can be used as biosignatures for extant life. In addition, we characterized phosphatases extracted from the Antarctica soil samples, and compared with those obtained from other types of environments. Antarctica surface environments are quite severe environments for life since it is extremely cold and dry and exposed to strong UV and cosmic rays. We tried to evaluate biological activities in Antarctica by measuring phosphatase activities. Surface soil samples are obtained at the Sites 1-8 near Showa Base in Antarctica during the 47th Japan Antarctic exploration mission in 2005-6. Activities of acid phosphatase (ACP) and alkaline phosphatase (ALP) are measured spectrophotometrically after mixing the powdered sample and p-nitrophenyl phosphate solution (pH 6.5 for ACP, pH 8.0 for ALP). ALP was characterized after extraction from soils with

  1. Analyses of ammonium in geologic samples: comparison of indophenol-blue and fluorometric methods

    NASA Astrophysics Data System (ADS)

    Johnson, B. W.; Goldblatt, C.; El-Sabaawi, R.; Hanson, N.

    2015-12-01

    Nitrogen in geologic materials is a tracer and record of biologic activity. Analysis can be difficult, however, as concentrations are often low (~1s to 10s ppm). The most stable form for N to be preserved in rocks and minerals is as NH4+, which is derived from organic matter and substitutes into mineral lattices for K+. Thus, measuring NH4+ content serves as a good proxy for total N content. Fluorometry (FL) is the standard technique for aqueous samples, and has a number of advantages over older indophenol-blue based, colorimetric (IBC) techniques (Hall, 1993). These include lower sample processing time, safer reagents, more stable reactions, and greater precision. In this study, I adapt a fluorometry technique (Holmes et al., 1999) for use in analyzing NH4+ concentration in geologic materials.Samples and standards were dissolved in hydrofluoric acid, neutralized with potassium hydroxide, then analyzed either with FL or IBC. As part of IBC, a distillation step was carried out to concentrate NH4+, and both techniques were used after this step to as well. Initial results show promise, as reproducible, ppm-level concentrations are demonstrated in several different rock types of various ages: Neoproterozoic siliciclastic sediments, a Jurassic granodiorite, a Cretaceous serpentinite, and Neoproterozoic carbonates. Concentrations are comparable between the two methods, though curiously fluorometry indicates NH4+ concentrations about 22% lower. Distillation appears effective in strengthening the signal for FL, though it may not be necessary for accurate results.There are several factors affecting the quality of FL. Sample pH appears to be the most important. At pH>9, NH3 is stable, and can easily escape a solution. Ensuring samples remain below pH 9 should prove key. Additional tests are being carried out to improve sample recovery, lessen time of HF dissolution, and improve accuracy.This new application of a standard technique should prove useful not only in determining

  2. An improved regulatory sampling method for mapping and representing plant disease from a limited number of samples.

    PubMed

    Luo, W; Pietravalle, S; Parnell, S; van den Bosch, F; Gottwald, T R; Irey, M S; Parker, S R

    2012-06-01

    A key challenge for plant pathologists is to develop efficient methods to describe spatial patterns of disease spread accurately from a limited number of samples. Knowledge of disease spread is essential for informing and justifying plant disease management measures. A mechanistic modelling approach is adopted for disease mapping which is based on disease dispersal gradients and consideration of host pattern. The method is extended to provide measures of uncertainty for the estimates of disease at each host location. In addition, improvements have been made to increase computational efficiency by better initialising the disease status of unsampled hosts and speeding up the optimisation process of the model parameters. These improvements facilitate the practical use of the method by providing information on: (a) mechanisms of pathogen dispersal, (b) distance and pattern of disease spread, and (c) prediction of infection probabilities for unsampled hosts. Two data sets of disease observations, Huanglongbing (HLB) of citrus and strawberry powdery mildew, were used to evaluate the performance of the new method for disease mapping. The result showed that our method gave better estimates of precision for unsampled hosts, compared to both the original method and spatial interpolation. This enables decision makers to understand the spatial aspects of disease processes, and thus formulate regulatory actions accordingly to enhance disease control. PMID:22664065

  3. Comparability among four invertebrate sampling methods, Fountain Creek Basin, Colorado, 2010-2012

    USGS Publications Warehouse

    Zuellig, Robert E.; Bruce, James F.; Stogner, Robert W.; Brown, Krystal D.

    2014-01-01

    The U.S. Geological Survey, in cooperation with Colorado Springs City Engineering and Colorado Springs Utilities, designed a study to determine if sampling method and sample timing resulted in comparable samples and assessments of biological condition. To accomplish this task, annual invertebrate samples were collected concurrently using four sampling methods at 15 U.S. Geological Survey streamflow gages in the Fountain Creek basin from 2010 to 2012. Collectively, the four methods are used by local (U.S. Geological Survey cooperative monitoring program) and State monitoring programs (Colorado Department of Public Health and Environment) in the Fountain Creek basin to produce two distinct sample types for each program that target single-and multiple-habitats. This study found distinguishable differences between single-and multi-habitat sample types using both community similarities and multi-metric index values, while methods from each program within sample type were comparable. This indicates that the Colorado Department of Public Health and Environment methods were compatible with the cooperative monitoring program methods within multi-and single-habitat sample types. Comparisons between September and October samples found distinguishable differences based on community similarities for both sample types, whereas only differences were found for single-habitat samples when multi-metric index values were considered. At one site, differences between September and October index values from single-habitat samples resulted in opposing assessments of biological condition. Direct application of the results to inform the revision of the existing Fountain Creek basin U.S. Geological Survey cooperative monitoring program are discussed.

  4. Molecular cancer classification using a meta-sample-based regularized robust coding method

    PubMed Central

    2014-01-01

    Motivation Previous studies have demonstrated that machine learning based molecular cancer classification using gene expression profiling (GEP) data is promising for the clinic diagnosis and treatment of cancer. Novel classification methods with high efficiency and prediction accuracy are still needed to deal with high dimensionality and small sample size of typical GEP data. Recently the sparse representation (SR) method has been successfully applied to the cancer classification. Nevertheless, its efficiency needs to be improved when analyzing large-scale GEP data. Results In this paper we present the meta-sample-based regularized robust coding classification (MRRCC), a novel effective cancer classification technique that combines the idea of meta-sample-based cluster method with regularized robust coding (RRC) method. It assumes that the coding residual and the coding coefficient are respectively independent and identically distributed. Similar to meta-sample-based SR classification (MSRC), MRRCC extracts a set of meta-samples from the training samples, and then encodes a testing sample as the sparse linear combination of these meta-samples. The representation fidelity is measured by the l2-norm or l1-norm of the coding residual. Conclusions Extensive experiments on publicly available GEP datasets demonstrate that the proposed method is more efficient while its prediction accuracy is equivalent to existing MSRC-based methods and better than other state-of-the-art dimension reduction based methods. PMID:25473795

  5. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    PubMed

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  6. Application of enhanced sampling methods to mineral nucleation and growth processes

    NASA Astrophysics Data System (ADS)

    Wallace, A. F.

    2013-12-01

    Mineral nucleation and growth are amongst the most critical processes occurring in natural environments. However, even with high-resolution in situ techniques such as Atomic Force Microscopy (AFM), mechanistic details must typically be inferred from kinetic measurements. Computational methods are potentially powerful tools which may assist in understanding aspects of mineral reactivity, however, in practice standard approaches effectively probe only those processes whose associated activation barriers are comparable to the ambient thermal energy (kBT). Therefore, due to inherent limitations on the simulation accessible timescale, many reactions of geochemical interest continue to challenge existing computational strategies. Enhanced sampling methods increase the rate at which rare events occur in atomistic simulations by accelerating the exploration of the free energy landscape. Here, two such methods are applied to aspects of calcium carbonate nucleation and growth. Replica exchange molecular dynamics (REMD) is used to explore the initial formation of hydrated mineral clusters from solution (Wallace et al., in press, Science). Characterization of the thermodynamic and dynamic properties of the clusters suggests that a dense liquid phase of calcium carbonate forms under certain conditions. Additionally, it is demonstrated that coalescence of the dense liquid products of the liquid-liquid separation results in the formation of a solid phase whose structure is consistent with amorphous calcium carbonate. Results from forward flux sampling (FFS) simulations are also presented. The rate of solvent exchange about calcium ions in solution is rapid enough to be determined directly from a standard molecular dynamics simulation and is used in this instance to calibrate the FFS method. The calibrated procedure is then applied to obtain preliminary rates of ion attachment and detachment from calcite surfaces.

  7. Environmental and mental conditions predicting the experience of involuntary musical imagery: An experience sampling method study.

    PubMed

    Floridou, Georgia A; Müllensiefen, Daniel

    2015-05-01

    An experience sampling method (ESM) study on 40 volunteers was conducted to explore the environmental factors and psychological conditions related to involuntary musical imagery (INMI) in everyday life. Participants reported 6 times per day for one week on their INMI experiences, relevant contextual information and associated environmental conditions. The resulting data was modeled with Bayesian networks and led to insights into the interplay of factors related to INMI experiences. The activity that a person is engaged was found to play an important role in the experience of mind wandering, which in turn enables the experience of INMI. INMI occurrence is independent of the time of the day while the INMI trigger affects the subjective evaluation of the INMI experience. The results are compared to findings from earlier studies based on retrospective surveys and questionnaires and highlight the advantage of ESM techniques in research on spontaneous experiences like INMI. PMID:25800098

  8. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection.

    PubMed

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-07-28

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel "melting temperature (Tm) mapping method" for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a "match" or "broad match" with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment.

  9. A case-base sampling method for estimating recurrent event intensities.

    PubMed

    Saarela, Olli

    2016-10-01

    Case-base sampling provides an alternative to risk set sampling based methods to estimate hazard regression models, in particular when absolute hazards are also of interest in addition to hazard ratios. The case-base sampling approach results in a likelihood expression of the logistic regression form, but instead of categorized time, such an expression is obtained through sampling of a discrete set of person-time coordinates from all follow-up data. In this paper, in the context of a time-dependent exposure such as vaccination, and a potentially recurrent adverse event outcome, we show that the resulting partial likelihood for the outcome event intensity has the asymptotic properties of a likelihood. We contrast this approach to self-matched case-base sampling, which involves only within-individual comparisons. The efficiency of the case-base methods is compared to that of standard methods through simulations, suggesting that the information loss due to sampling is minimal.

  10. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    NASA Astrophysics Data System (ADS)

    Adamic, M. L.; Lister, T. E.; Dufek, E. J.; Jenson, D. D.; Olson, J. E.; Vockenhuber, C.; Watrous, M. G.

    2015-10-01

    This paper presents an evaluation of an alternate method for preparing environmental samples for 129I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  11. Sampling/analytical method evaluation for ethylene oxide emission and control-unit efficiency determinations

    SciTech Connect

    Steger, J.; Gergen, W.; Margeson, J.H.

    1988-05-01

    Radian Corporation, assisting the Environmental Monitoring Systems Laboratory, Environmental Protection Agency, Research Triangle Park, North Carolina, performed a field evaluation of a method for sampling and analyzing ethylene oxide (EO) in the vent stream from a sterilization chamber and a dilute-acid scrubber. The utility of the sampling method for measuring the efficiency of the control unit was also evaluated. The evaluated sampling and analysis procedure used semi-continuous direct sampling with on-line gas chromatographic analysis. Laboratory studies of the sampling method previous to the field test showed that semi-continuous direct sampling was capable of measuring EO emissions to within 11% of the expected value with a between-trial precision of 5%.

  12. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    SciTech Connect

    Adamic, M. L.; Lister, T. E.; Dufek, E. J.; Jenson, D. D.; Olson, J. E.; Vockenhuber, C.; Watrous, M. G.

    2015-03-25

    This paper presents an evaluation of an alternate method for preparing environmental samples for 129I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Furthermore, precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  13. Determination of ATP-activity as a useful tool for monitoring microbial load in aqueous humidifier samples.

    PubMed

    Liebers, Verena; Bachmann, Dieter; Franke, Gabriele; Freundt, Susanne; Stubel, Heike; Düser, Maria; Kendzia, Benjamin; Böckler, Margret; Brüning, Thomas; Raulf, Monika

    2015-03-01

    Air humidifier water tanks are potential sources of microbial contaminants. Aerosolization of these contaminants is associated with the development of airway and lung diseases; therefore, implementation of preventive strategies including monitoring of the microbial contamination is recommended. So far, culture-based methods that include measuring colony forming units (CFU) are widely used to monitor microbial load. However, these methods are time consuming and have considerable drawbacks. As a result, alternative methods are needed which provide not only clear and accurate results concerning microbial load in water samples, but are also rapid and easy to use in the field. This paper reports on a rapid test for ATP quantification as an alternative method for microbial monitoring, including its implementation, validation and application in the field. For this purpose, 186 water samples were characterized with different methods, which included ATP analysis, culture-based methods, endotoxin activity (common and rapid test), pyrogenic activity and number of particles. Half of the samples was measured directly in the field and the other half one day later in the laboratory. The results of both tests are highly correlated. Furthermore, to check how representative the result from one sample of a water source is, a second sample of the same water tank were collected and measured. Bioluminescence results of the undiluted samples covered a range between 20 and 25,000 relative light units (RLU) and correlated with the results obtained using the other methods. The highest correlation was found between bioluminescence and endotoxin activity (rs=0.79) as well as pyrogenic activity (rs=0.75). Overall, the results of this study indicate that ATP measurement using bioluminescence is a suitable tool to obtain rapid, reproducible and sensitive information on the microbial load of water samples, and is suitable to use in the field. However, to use ATP measurement as an indicator of

  14. Modified shifted angular spectrum method for numerical propagation at reduced spatial sampling rates.

    PubMed

    Ritter, André

    2014-10-20

    The shifted angular spectrum method allows a reduction of the number of samples required for numerical off-axis propagation of scalar wave fields. In this work, a modification of the shifted angular spectrum method is presented. It allows a further reduction of the spatial sampling rate for certain wave fields. We calculate the benefit of this method for spherical waves. Additionally, a working implementation is presented showing the example of a spherical wave propagating through a circular aperture. PMID:25401659

  15. Guidance for characterizing explosives contaminated soils: Sampling and selecting on-site analytical methods

    SciTech Connect

    Crockett, A.B.; Craig, H.D.; Jenkins, T.F.; Sisk, W.E.

    1996-09-01

    A large number of defense-related sites are contaminated with elevated levels of secondary explosives. Levels of contamination range from barely detectable to levels above 10% that need special handling due to the detonation potential. Characterization of explosives-contaminated sites is particularly difficult due to the very heterogeneous distribution of contamination in the environment and within samples. To improve site characterization, several options exist including collecting more samples, providing on-site analytical data to help direct the investigation, compositing samples, improving homogenization of samples, and extracting larger samples. On-site analytical methods are essential to more economical and improved characterization. On-site methods might suffer in terms of precision and accuracy, but this is more than offset by the increased number of samples that can be run. While verification using a standard analytical procedure should be part of any quality assurance program, reducing the number of samples analyzed by the more expensive methods can result in significantly reduced costs. Often 70 to 90% of the soil samples analyzed during an explosives site investigation do not contain detectable levels of contamination. Two basic types of on-site analytical methods are in wide use for explosives in soil, calorimetric and immunoassay. Calorimetric methods generally detect broad classes of compounds such as nitroaromatics or nitramines, while immunoassay methods are more compound specific. Since TNT or RDX is usually present in explosive-contaminated soils, the use of procedures designed to detect only these or similar compounds can be very effective.

  16. Comparison of individual and pooled sampling methods for detecting bacterial pathogens of fish

    USGS Publications Warehouse

    Mumford, Sonia; Patterson, Chris; Evered, J.; Brunson, Ray; Levine, J.; Winton, J.

    2005-01-01

    Examination of finfish populations for viral and bacterial pathogens is an important component of fish disease control programs worldwide. Two methods are commonly used for collecting tissue samples for bacteriological culture, the currently accepted standards for detection of bacterial fish pathogens. The method specified in the Office International des Epizooties Manual of Diagnostic Tests for Aquatic Animals permits combining renal and splenic tissues from as many as 5 fish into pooled samples. The American Fisheries Society (AFS) Blue Book/US Fish and Wildlife Service (USFWS) Inspection Manual specifies the use of a bacteriological loop for collecting samples from the kidney of individual fish. An alternative would be to more fully utilize the pooled samples taken for virology. If implemented, this approach would provide substantial savings in labor and materials. To compare the relative performance of the AFS/USFWS method and this alternative approach, cultures of Yersinia ruckeri were used to establish low-level infections in groups of rainbow trout (Oncorhynchus mykiss) that were sampled by both methods. Yersinia ruckeri was cultured from 22 of 37 groups by at least 1 method. The loop method yielded 18 positive groups, with 1 group positive in the loop samples but negative in the pooled samples. The pooled samples produced 21 positive groups, with 4 groups positive in the pooled samples but negative in the loop samples. There was statistically significant agreement (Spearman coefficient 0.80, P < 0.001) in the relative ability of the 2 sampling methods to permit detection of low-level bacterial infections of rainbow trout.

  17. Simple method to measure power density entering a plane biological sample at millimeter wavelengths.

    PubMed

    Shen, Z Y; Birenbaum, L; Chu, A; Motzkin, S; Rosenthal, S; Sheng, K M

    1987-01-01

    A simple method for measuring microwave power density is described. It is applicable to situations where exposure of samples in the near field of a horn is necessary. A transmitted power method is used to calibrate the power density entering the surface of the sample. Once the calibration is available, the power density is known in terms of the incident and reflected powers within the waveguide. The calibration has been carried out for liquid samples in a quartz cell. Formulas for calculating specific absorption rate (SAR) are derived in terms of the power density and the complex dielectric constant of the sample. An error analysis is also given.

  18. Quality assurance guidance for field sampling and measurement assessment plates in support of EM environmental sampling and analysis activities

    SciTech Connect

    Not Available

    1994-05-01

    This document is one of several guidance documents developed by the US Department of Energy (DOE) Office of Environmental Restoration and Waste Management (EM). These documents support the EM Analytical Services Program (ASP) and are based on applicable regulatory requirements and DOE Orders. They address requirements in DOE Orders by providing guidance that pertains specifically to environmental restoration and waste management sampling and analysis activities. DOE 5700.6C Quality Assurance (QA) defines policy and requirements to establish QA programs ensuring that risks and environmental impacts are minimized and that safety, reliability, and performance are maximized. This is accomplished through the application of effective management systems commensurate with the risks imposed by the facility and the project. Every organization supporting EM`s environmental sampling and analysis activities must develop and document a QA program. Management of each organization is responsible for appropriate QA program implementation, assessment, and improvement. The collection of credible and cost-effective environmental data is critical to the long-term success of remedial and waste management actions performed at DOE facilities. Only well established and management supported assessment programs within each EM-support organization will enable DOE to demonstrate data quality. The purpose of this series of documents is to offer specific guidance for establishing an effective assessment program for EM`s environmental sampling and analysis (ESA) activities.

  19. RAPID FUSION METHOD FOR DETERMINATION OF PLUTONIUM ISOTOPES IN LARGE RICE SAMPLES

    SciTech Connect

    Maxwell, S.

    2013-03-01

    A new rapid fusion method for the determination of plutonium in large rice samples has been developed at the Savannah River National Laboratory (Aiken, SC, USA) that can be used to determine very low levels of plutonium isotopes in rice. The recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid, reliable radiochemical analyses for radionuclides in environmental and food samples. Public concern regarding foods, particularly foods such as rice in Japan, highlights the need for analytical techniques that will allow very large sample aliquots of rice to be used for analysis so that very low levels of plutonium isotopes may be detected. The new method to determine plutonium isotopes in large rice samples utilizes a furnace ashing step, a rapid sodium hydroxide fusion method, a lanthanum fluoride matrix removal step, and a column separation process with TEVA Resin cartridges. The method can be applied to rice sample aliquots as large as 5 kg. Plutonium isotopes can be determined using alpha spectrometry or inductively-coupled plasma mass spectrometry (ICP-MS). The method showed high chemical recoveries and effective removal of interferences. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory plutonium particles are effectively digested. The MDA for a 5 kg rice sample using alpha spectrometry is 7E-5 mBq g{sup -1}. The method can easily be adapted for use by ICP-MS to allow detection of plutonium isotopic ratios.

  20. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; Utsey, Robin C.; Sudowe, Ralf; McAlister, Daniel R.

    2016-04-12

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89/90Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. Lastly, this approach has a sample preparation time for limestone and marble samples of <4 hours.

  1. DEVELOPMENT AND FIELD IMPLEMENTATION OF AN IMPROVED METHOD FOR HEADSPACE GAS SAMPLING OF TRANSURANIC WASTE DRUMS

    SciTech Connect

    Polley, M.; Ankrom, J.; Wickland, T.; Warren, J.

    2003-02-27

    A fast, safe, and cost-effective method for obtaining headspace gas samples has been developed and implemented at Los Alamos National Laboratory (LANL). A sample port is installed directly into a drum lid using a pneumatic driver, allowing sampling with a side-port needle. Testing has shown that the sample port can be installed with no release of radioactive material. Use of this system at LANL has significantly reduced the time required for sampling, and eliminates the need for many safety precautions previously used. The system has significantly improved productivity and lowered radiation exposure and cost.

  2. Single-Image Super-Resolution Using Active-Sampling Gaussian Process Regression.

    PubMed

    Wang, Haijun; Gao, Xinbo; Zhang, Kaibing; Li, Jie

    2016-02-01

    As well known, Gaussian process regression (GPR) has been successfully applied to example learning-based image super-resolution (SR). Despite its effectiveness, the applicability of a GPR model is limited by its remarkably computational cost when a large number of examples are available to a learning task. For this purpose, we alleviate this problem of the GPR-based SR and propose a novel example learning-based SR method, called active-sampling GPR (AGPR). The newly proposed approach employs an active learning strategy to heuristically select more informative samples for training the regression parameters of the GPR model, which shows significant improvement on computational efficiency while keeping higher quality of reconstructed image. Finally, we suggest an accelerating scheme to further reduce the time complexity of the proposed AGPR-based SR by using a pre-learned projection matrix. We objectively and subjectively demonstrate that the proposed method is superior to other competitors for producing much sharper edges and finer details. PMID:26841394

  3. Activity ratios of 137Cs, 90Sr and 239+240Pu in environmental samples.

    PubMed

    Bossew, P; Lettner, H; Hubmer, A; Erlinger, C; Gastberger, M

    2007-01-01

    Both global and Chernobyl fallout have resulted in environmental contamination with radionuclides such as 137Cs, 90Sr and 239+240Pu. In environmental samples, 137Cs and 239+240Pu can be divided into the contributions of either source, if also the isotopes 134Cs and 238Pu are measurable, based on the known isotopic ratios in global and Chernobyl fallout. No analogous method is available for 90Sr. The activity ratios of Sr to Cs and Pu, respectively, are known for the actual fallout mainly from air filter measurements; but due to the high mobility of Sr in the environment, compared to Cs and Pu, these ratios generally do not hold for the inventory many years after deposition. In this paper we suggest a method to identify the mean contributions of global and Chernobyl fallout to total Sr in soil, sediment and cryoconite samples from Alpine and pre-Alpine regions of Austria, based on a statistical evaluation of Sr/Cs/Pu radionuclide activity ratios. Results are given for Sr:Cs, Sr:Pu and Cs:Pu ratios. Comparison with fallout data shows a strong depletion of Sr against Cs and Pu. PMID:17407799

  4. Probe Heating Method for the Analysis of Solid Samples Using a Portable Mass Spectrometer.

    PubMed

    Kumano, Shun; Sugiyama, Masuyuki; Yamada, Masuyoshi; Nishimura, Kazushige; Hasegawa, Hideki; Morokuma, Hidetoshi; Inoue, Hiroyuki; Hashimoto, Yuichiro

    2015-01-01

    We previously reported on the development of a portable mass spectrometer for the onsite screening of illicit drugs, but our previous sampling system could only be used for liquid samples. In this study, we report on an attempt to develop a probe heating method that also permits solid samples to be analyzed using a portable mass spectrometer. An aluminum rod is used as the sampling probe. The powdered sample is affixed to the sampling probe or a droplet of sample solution is placed on the tip of the probe and dried. The probe is then placed on a heater to vaporize the sample. The vapor is then introduced into the portable mass spectrometer and analyzed. With the heater temperature set to 130°C, the developed system detected 1 ng of methamphetamine, 1 ng of amphetamine, 3 ng of 3,4-methylenedioxymethamphetamine, 1 ng of 3,4-methylenedioxyamphetamine, and 0.3 ng of cocaine. Even from mixtures consisting of clove powder and methamphetamine powder, methamphetamine ions were detected by tandem mass spectrometry. The developed probe heating method provides a simple method for the analysis of solid samples. A portable mass spectrometer incorporating this method would thus be useful for the onsite screening of illicit drugs. PMID:26819909

  5. Probe Heating Method for the Analysis of Solid Samples Using a Portable Mass Spectrometer.

    PubMed

    Kumano, Shun; Sugiyama, Masuyuki; Yamada, Masuyoshi; Nishimura, Kazushige; Hasegawa, Hideki; Morokuma, Hidetoshi; Inoue, Hiroyuki; Hashimoto, Yuichiro

    2015-01-01

    We previously reported on the development of a portable mass spectrometer for the onsite screening of illicit drugs, but our previous sampling system could only be used for liquid samples. In this study, we report on an attempt to develop a probe heating method that also permits solid samples to be analyzed using a portable mass spectrometer. An aluminum rod is used as the sampling probe. The powdered sample is affixed to the sampling probe or a droplet of sample solution is placed on the tip of the probe and dried. The probe is then placed on a heater to vaporize the sample. The vapor is then introduced into the portable mass spectrometer and analyzed. With the heater temperature set to 130°C, the developed system detected 1 ng of methamphetamine, 1 ng of amphetamine, 3 ng of 3,4-methylenedioxymethamphetamine, 1 ng of 3,4-methylenedioxyamphetamine, and 0.3 ng of cocaine. Even from mixtures consisting of clove powder and methamphetamine powder, methamphetamine ions were detected by tandem mass spectrometry. The developed probe heating method provides a simple method for the analysis of solid samples. A portable mass spectrometer incorporating this method would thus be useful for the onsite screening of illicit drugs.

  6. Probe Heating Method for the Analysis of Solid Samples Using a Portable Mass Spectrometer

    PubMed Central

    Kumano, Shun; Sugiyama, Masuyuki; Yamada, Masuyoshi; Nishimura, Kazushige; Hasegawa, Hideki; Morokuma, Hidetoshi; Inoue, Hiroyuki; Hashimoto, Yuichiro

    2015-01-01

    We previously reported on the development of a portable mass spectrometer for the onsite screening of illicit drugs, but our previous sampling system could only be used for liquid samples. In this study, we report on an attempt to develop a probe heating method that also permits solid samples to be analyzed using a portable mass spectrometer. An aluminum rod is used as the sampling probe. The powdered sample is affixed to the sampling probe or a droplet of sample solution is placed on the tip of the probe and dried. The probe is then placed on a heater to vaporize the sample. The vapor is then introduced into the portable mass spectrometer and analyzed. With the heater temperature set to 130°C, the developed system detected 1 ng of methamphetamine, 1 ng of amphetamine, 3 ng of 3,4-methylenedioxymethamphetamine, 1 ng of 3,4-methylenedioxyamphetamine, and 0.3 ng of cocaine. Even from mixtures consisting of clove powder and methamphetamine powder, methamphetamine ions were detected by tandem mass spectrometry. The developed probe heating method provides a simple method for the analysis of solid samples. A portable mass spectrometer incorporating this method would thus be useful for the onsite screening of illicit drugs. PMID:26819909

  7. A green method for the determination of cocaine in illicit samples.

    PubMed

    Pérez-Alfonso, Clara; Galipienso, Nieves; Garrigues, Salvador; de la Guardia, Miguel

    2014-04-01

    Direct determination of cocaine in untreated seized samples has been made based on diffuse reflectance measurements of the near infrared (NIR) radiation through samples contained inside standard glass vials. The method used a series of previously analyzed samples, by the reference gas chromatography method, to build a partial least squares calibration model which was validated using an independent set of samples. The use of a general model for samples containing from 11.38% till 86.44% (w/w) cocaine was based on the use of spectral ranges from 12500.7 to 10128.6, 9339.8 to 6967.7 and 5388.3 to 4597.6cm(-1) with previous first derivative and vector normalization data pre-processing and provided a root mean square error of prediction (RMSEP) of 4.0% (w/w) with a residual prediction deviation (RPD) of 3.9% (w/w), based on the use of 8 latent variables, 34 samples for calibration and an independent set of 44 samples for validation. The aforementioned results could be improved on considering two separate models, one for high concentrated bulk samples and another for samples diluted with cutting agents. Additionally a new set of batch samples with cocaine concentrations from 60% till 84% was evaluated by using the developed method. PMID:24607706

  8. Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W.

    1974-01-01

    The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

  9. Quantifying ChIP-seq data: a spiking method providing an internal reference for sample-to-sample normalization.

    PubMed

    Bonhoure, Nicolas; Bounova, Gergana; Bernasconi, David; Praz, Viviane; Lammers, Fabienne; Canella, Donatella; Willis, Ian M; Herr, Winship; Hernandez, Nouria; Delorenzi, Mauro

    2014-07-01

    Chromatin immunoprecipitation followed by deep sequencing (ChIP-seq) experiments are widely used to determine, within entire genomes, the occupancy sites of any protein of interest, including, for example, transcription factors, RNA polymerases, or histones with or without various modifications. In addition to allowing the determination of occupancy sites within one cell type and under one condition, this method allows, in principle, the establishment and comparison of occupancy maps in various cell types, tissues, and conditions. Such comparisons require, however, that samples be normalized. Widely used normalization methods that include a quantile normalization step perform well when factor occupancy varies at a subset of sites, but may miss uniform genome-wide increases or decreases in site occupancy. We describe a spike adjustment procedure (SAP) that, unlike commonly used normalization methods intervening at the analysis stage, entails an experimental step prior to immunoprecipitation. A constant, low amount from a single batch of chromatin of a foreign genome is added to the experimental chromatin. This "spike" chromatin then serves as an internal control to which the experimental signals can be adjusted. We show that the method improves similarity between replicates and reveals biological differences including global and largely uniform changes.

  10. Evaluation of gravimetric methods for dissoluble matter in extracts of environmental samples

    SciTech Connect

    Lafleur, A.L.; Monchamp, P.A.; Plummer, E.F.; Kruzel, E.L.

    1986-01-01

    A number of gravimetric methods were evaluated for the determination of dissolved matter in solvent extracts of combustion samples. The methods described included thermogravimetric analysis, weighing after evaporation under nitrogen, and a microscale evaporation method developed in this study. A well characterized combustion sample, known to consist primarily of alkylated bicyclic and tricyclic aromatic compounds, served as a reference material. Results for the three methods are presented and compared. Although the thermogravimetric analyzer was found to be accurate and versatile, a good compromise between cost, time and accuracy was provided by the microscale evaporation method.

  11. Dual stage active magnetic regenerator and method

    DOEpatents

    Pecharsky, Vitalij K.; Gschneidner, Jr., Karl A.

    1999-03-30

    A dual stage active magnetic regenerator refrigerator as well as method using the Joule-Brayton thermodynamic cycle includes a high temperature stage refrigerant comprising DyAl.sub.2 or (Dy.sub.1-x Er.sub.x)Al.sub.2 where x is selected to be greater than 0 and less than about 0.3 in combination with a low temperature stage comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 where x is selected to be greater than about 0.5 and less than 1 to provide significantly improved refrigeration efficiency in the liquefaction of gaseous hydrogen.

  12. Dual stage active magnetic regenerator and method

    DOEpatents

    Pecharsky, V.K.; Gschneidner, K.A. Jr.

    1999-03-30

    A dual stage active magnetic regenerator refrigerator as well as method using the Joule-Brayton thermodynamic cycle includes a high temperature stage refrigerant comprising DyAl{sub 2} or (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} where x is selected to be greater than 0 and less than about 0.3 in combination with a low temperature stage comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} where x is selected to be greater than about 0.5 and less than 1 to provide significantly improved refrigeration efficiency in the liquefaction of gaseous hydrogen. 17 figs.

  13. System and method for monitoring cellular activity

    NASA Technical Reports Server (NTRS)

    Bearman, Gregory H. (Inventor); Fraser, Scott E. (Inventor); Lansford, Russell D. (Inventor)

    2004-01-01

    A system and method for monitoring cellular activity in a cellular specimen. According to one embodiment, a plurality of excitable markers are applied to the specimen. A multi-photon laser microscope is provided to excite a region of the specimen and cause fluorescence to be radiated from the region. The radiating fluorescence is processed by a spectral analyzer to separate the fluorescence into respective wavelength bands. The respective bands of fluorescence are then collected by an array of detectors, with each detector receiving a corresponding one of the wavelength bands.

  14. System and method for monitoring cellular activity

    NASA Technical Reports Server (NTRS)

    Bearman, Gregory H. (Inventor); Fraser, Scott E. (Inventor); Lansford, Russell D. (Inventor)

    2002-01-01

    A system and method for monitoring cellular activity in a cellular specimen. According to one embodiment, a plurality of excitable markers are applied to the specimen. A multi-photon laser microscope is provided to excite a region of the specimen and cause fluorescence to be radiated from the region. The radiating fluorescence is processed by a spectral analyzer to separate the fluorescence into respective wavelength bands. The respective bands of fluorescence are then collected by an array of detectors, with each detector receiving a corresponding one of the wavelength bands.

  15. A stochastic optimization method to estimate the spatial distribution of a pathogen from a sample.

    PubMed

    Parnell, S; Gottwald, T R; Irey, M S; Luo, W; van den Bosch, F

    2011-10-01

    Information on the spatial distribution of plant disease can be utilized to implement efficient and spatially targeted disease management interventions. We present a pathogen-generic method to estimate the spatial distribution of a plant pathogen using a stochastic optimization process which is epidemiologically motivated. Based on an initial sample, the method simulates the individual spread processes of a pathogen between patches of host to generate optimized spatial distribution maps. The method was tested on data sets of Huanglongbing of citrus and was compared with a kriging method from the field of geostatistics using the well-established kappa statistic to quantify map accuracy. Our method produced accurate maps of disease distribution with kappa values as high as 0.46 and was able to outperform the kriging method across a range of sample sizes based on the kappa statistic. As expected, map accuracy improved with sample size but there was a high amount of variation between different random sample placements (i.e., the spatial distribution of samples). This highlights the importance of sample placement on the ability to estimate the spatial distribution of a plant pathogen and we thus conclude that further research into sampling design and its effect on the ability to estimate disease distribution is necessary. PMID:21916625

  16. NREL Develops Accelerated Sample Activation Process for Hydrogen Storage Materials (Fact Sheet)

    SciTech Connect

    Not Available

    2010-12-01

    This fact sheet describes NREL's accomplishments in developing a new sample activation process that reduces the time to prepare samples for measurement of hydrogen storage from several days to five minutes and provides more uniform samples. Work was performed by NREL's Chemical and Materials Science Center.

  17. New method for monitoring nitric oxide in vivo using microdialysis sampling and chemiluminescence reaction

    NASA Astrophysics Data System (ADS)

    Yao, Dachun; Evmiridis, Nick P.; Zhou, Yikai; Xu, Shunqing; Zhou, Huarong

    2001-09-01

    A new method employing a combination of micro dialysis sampling and chemiluminescence reaction was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve a very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. We have established that this system is sensitive enough to detect variations in NO production in difference physiological state. The system can detect NO in the linear range of 5nM-1(mu) M, with a detection limit of 1nM, and real NO concentrations in our experimental animals were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors, NO interference were investigated carefully in different physiological situations.

  18. Nuclear and conventional methods for soil determination in sugar cane industry. Validity of sampling procedure.

    PubMed

    Fernandes, E A; Bacchi, M A

    1994-01-01

    Scandium and ash methods' performances were compared in terms of soil content assessment in sugar cane loads, emphasizing the common sampling drawbacks. Both methods are adequate for such determination in controlled conditions. The scandium has demonstrated better analytical characteristics, since it is free from interferences of cane matrix, which decreases the accuracy of the ash method in normal mill conditions.

  19. Methods, compounds and systems for detecting a microorganism in a sample

    DOEpatents

    Colston, Jr, Bill W.; Fitch, J. Patrick; Gardner, Shea N.; Williams, Peter L.; Wagner, Mark C.

    2016-09-06

    Methods to identify a set of probe polynucleotides suitable for detecting a set of targets and in particular methods for identification of primers suitable for detection of target microorganisms related polynucleotides, set of polynucleotides and compositions, and related methods and systems for detection and/or identification of microorganisms in a sample.

  20. Passive sampling methods for contaminated sediments: State of the science for organic contaminants

    PubMed Central

    Lydy, Michael J; Landrum, Peter F; Oen, Amy MP; Allinson, Mayumi; Smedes, Foppe; Harwood, Amanda D; Li, Huizhen; Maruya, Keith A; Liu, Jingfu

    2014-01-01

    This manuscript surveys the literature on passive sampler methods (PSMs) used in contaminated sediments to assess the chemical activity of organic contaminants. The chemical activity in turn dictates the reactivity and bioavailability of contaminants in sediment. Approaches to measure specific binding of compounds to sediment components, for example, amorphous carbon or specific types of reduced carbon, and the associated partition coefficients are difficult to determine, particularly for native sediment. Thus, the development of PSMs that represent the chemical activity of complex compound–sediment interactions, expressed as the freely dissolved contaminant concentration in porewater (Cfree), offer a better proxy for endpoints of concern, such as reactivity, bioaccumulation, and toxicity. Passive sampling methods have estimated Cfree using both kinetic and equilibrium operating modes and used various polymers as the sorbing phase, for example, polydimethylsiloxane, polyethylene, and polyoxymethylene in various configurations, such as sheets, coated fibers, or vials containing thin films. These PSMs have been applied in laboratory exposures and field deployments covering a variety of spatial and temporal scales. A wide range of calibration conditions exist in the literature to estimate Cfree, but consensus values have not been established. The most critical criteria are the partition coefficient between water and the polymer phase and the equilibrium status of the sampler. In addition, the PSM must not appreciably deplete Cfree in the porewater. Some of the future challenges include establishing a standard approach for PSM measurements, correcting for nonequilibrium conditions, establishing guidance for selection and implementation of PSMs, and translating and applying data collected by PSMs. Integr Environ Assess Manag 2014;10:167–178. © 2014 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of

  1. Determination of seven noble metals in standard rock samples by means of thermal neutron activation analysis.

    PubMed

    Ayabe, M; Hirao, Y; Kimura, K

    1980-10-01

    Ruthenium, silver, rhenium, osmium, iridium, platinum and gold in standard rock samples from Geological Survey of Japan (JB-1, JB-2, JG-1 and JA-1) were determined by thermal neutron activation method with a systematic chemical separation. U.S. Geological Survey standard rocks (BCR-1 and G-2) were also analyzed to obtain an information about the accuracy and precision on the method. Generally agreement of our results with previous values for BCR-1 and G-2 was excellent. The noble metal contents in the igneous rocks from Japanese region were approximately comparable to those in the corresponding rocks from the continental region, and showed a tendency to decrease with increasing silica contents, with weak interrelations to other major elements.

  2. A comparison of microscopic and spectroscopic identification methods for analysis of microplastics in environmental samples.

    PubMed

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon

    2015-04-15

    The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (<1mm) were compared using the same samples from the sea surface microlayer (SML) and beach sand. Fragmented microplastics were significantly (p<0.05) underestimated and fiber was significantly overestimated using the stereomicroscope both in the SML and beach samples. The total abundance by FT-IR was higher than by microscope both in the SML and beach samples, but they were not significantly (p>0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution. PMID:25682567

  3. A comparison of microscopic and spectroscopic identification methods for analysis of microplastics in environmental samples.

    PubMed

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon

    2015-04-15

    The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (<1mm) were compared using the same samples from the sea surface microlayer (SML) and beach sand. Fragmented microplastics were significantly (p<0.05) underestimated and fiber was significantly overestimated using the stereomicroscope both in the SML and beach samples. The total abundance by FT-IR was higher than by microscope both in the SML and beach samples, but they were not significantly (p>0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution.

  4. Apparatus and method for maintaining multi-component sample gas constituents in vapor phase during sample extraction and cooling

    DOEpatents

    Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert

    2010-05-11

    A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.

  5. A unified method to process biosolids samples for the recovery of bacterial, viral, and helminths pathogens.

    PubMed

    Alum, Absar; Rock, Channah; Abbaszadegan, Morteza

    2014-01-01

    For land application, biosolids are classified as Class A or Class B based on the levels of bacterial, viral, and helminths pathogens in residual biosolids. The current EPA methods for the detection of these groups of pathogens in biosolids include discrete steps. Therefore, a separate sample is processed independently to quantify the number of each group of the pathogens in biosolids. The aim of the study was to develop a unified method for simultaneous processing of a single biosolids sample to recover bacterial, viral, and helminths pathogens. At the first stage for developing a simultaneous method, nine eluents were compared for their efficiency to recover viruses from a 100 gm spiked biosolids sample. In the second stage, the three top performing eluents were thoroughly evaluated for the recovery of bacteria, viruses, and helminthes. For all three groups of pathogens, the glycine-based eluent provided higher recovery than the beef extract-based eluent. Additional experiments were performed to optimize performance of glycine-based eluent under various procedural factors such as, solids to eluent ratio, stir time, and centrifugation conditions. Last, the new method was directly compared with the EPA methods for the recovery of the three groups of pathogens spiked in duplicate samples of biosolids collected from different sources. For viruses, the new method yielded up to 10% higher recoveries than the EPA method. For bacteria and helminths, recoveries were 74% and 83% by the new method compared to 34% and 68% by the EPA method, respectively. The unified sample processing method significantly reduces the time required for processing biosolids samples for different groups of pathogens; it is less impacted by the intrinsic variability of samples, while providing higher yields (P = 0.05) and greater consistency than the current EPA methods.

  6. Sampling Methods for Detection and Monitoring of the Asian Citrus Psyllid (Hemiptera: Psyllidae).

    PubMed

    Monzo, C; Arevalo, H A; Jones, M M; Vanaclocha, P; Croxton, S D; Qureshi, J A; Stansly, P A

    2015-06-01

    The Asian citrus psyllid (ACP), Diaphorina citri Kuwayama is a key pest of citrus due to its role as vector of citrus greening disease or "huanglongbing." ACP monitoring is considered an indispensable tool for management of vector and disease. In the present study, datasets collected between 2009 and 2013 from 245 citrus blocks were used to evaluate precision, sensitivity for detection, and efficiency of five sampling methods. The number of samples needed to reach a 0.25 standard error-mean ratio was estimated using Taylor's power law and used to compare precision among sampling methods. Comparison of detection sensitivity and time expenditure (cost) between stem-tap and other sampling methodologies conducted consecutively at the same location were also assessed. Stem-tap sampling was the most efficient sampling method when ACP densities were moderate to high and served as the basis for comparison with all other methods. Protocols that grouped trees near randomly selected locations across the block were more efficient than sampling trees at random across the block. Sweep net sampling was similar to stem-taps in number of captures per sampled unit, but less precise at any ACP density. Yellow sticky traps were 14 times more sensitive than stem-taps but much more time consuming and thus less efficient except at very low population densities. Visual sampling was efficient for detecting and monitoring ACP at low densities. Suction sampling was time consuming and taxing but the most sensitive of all methods for detection of sparse populations. This information can be used to optimize ACP monitoring efforts. PMID:26313984

  7. Quantification of creatinine in biological samples based on the pseudoenzyme activity of copper-creatinine complex

    NASA Astrophysics Data System (ADS)

    Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Krishna, Honnur

    Glomerular filtration rate (GFR), the marker of chronic kidney disease can be analyzed by the concentration of cystatin C or creatinine and its clearance in human urine and serum samples. The determination of cystatin C alone as an indicator of GFR does not provide high accuracy, and is more expensive, thus measurement of creatinine has an important role in estimating GFR. We have made an attempt to quantify creatinine based on its pseudoenzyme activity of creatinine in the presence of copper. Creatinine in the presence of copper oxidizes paraphenylenediamine dihydrochloride (PPDD) which couples with dimethylamino benzoicacid (DMAB) giving green colored chromogenic product with maximum absorbance at 710 nm. Kinetic parameters relating this reaction were evaluated. Analytical curves of creatinine by fixed time and rate methods were linear at 8.8-530 μmol L-1 and 0.221-2.65 mmol L-1, respectively. Recovery of creatinine varied from 97.8 to 107.8%. Limit of detection and limit of quantification were 2.55 and 8.52 μmol L-1 respectively whereas Sandell's sensitivity and molar absorption coefficient values were 0.0407 μg cm-2 and 0.1427 × 104 L mol-1 cm-1 respectively. Precision studies showed that within day imprecision was 0.745-1.26% and day-to-day imprecision was 1.55-3.65%. The proposed method was applied to human urine and serum samples and results were validated in accordance with modified Jaffe's procedure. Wide linearity ranges with good recovery, less tolerance from excipients and application of the method to serum and urine samples are the claims which ascertain much advantage to this method.

  8. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  9. Evaluation and characterization of thyroid-disrupting activities in soil samples along the Second Songhua River, China.

    PubMed

    Kong, Dongdong; Wang, Yafei; Wang, Jinsheng; Teng, Yanguo; Li, Na; Li, Jian

    2016-11-01

    In this study, a recombinant thyroid receptor (TR) gene yeast assay combined with Monte Carlo simulation were used to evaluate and characterize soil samples collected from Jilin (China) along the Second Songhua River, for their ant/agonist effect on TR. No TR agonistic activity was found in soils, but many soil samples exhibited TR antagonistic activities, and the bioassay-derived amiodarone hydrochloride equivalents, which was calculated based on Monte Carlo simulation, ranged from not detected (N.D.) to 35.5μg/g. Hydrophilic substance fractions were determined to be the contributors to TR antagonistic activity in these soil samples. Our results indicate that the novel calculation method is effective for the quantification and characterization of TR antagonists in soil samples, and these data could provide useful information for future management and remediation efforts for contaminated soils. PMID:27526021

  10. Evaluation and characterization of thyroid-disrupting activities in soil samples along the Second Songhua River, China.

    PubMed

    Kong, Dongdong; Wang, Yafei; Wang, Jinsheng; Teng, Yanguo; Li, Na; Li, Jian

    2016-11-01

    In this study, a recombinant thyroid receptor (TR) gene yeast assay combined with Monte Carlo simulation were used to evaluate and characterize soil samples collected from Jilin (China) along the Second Songhua River, for their ant/agonist effect on TR. No TR agonistic activity was found in soils, but many soil samples exhibited TR antagonistic activities, and the bioassay-derived amiodarone hydrochloride equivalents, which was calculated based on Monte Carlo simulation, ranged from not detected (N.D.) to 35.5μg/g. Hydrophilic substance fractions were determined to be the contributors to TR antagonistic activity in these soil samples. Our results indicate that the novel calculation method is effective for the quantification and characterization of TR antagonists in soil samples, and these data could provide useful information for future management and remediation efforts for contaminated soils.

  11. Fast egg collection method greatly improves randomness of egg sampling in Drosophila melanogaster.

    PubMed

    Schou, Mads Fristrup

    2013-01-01

    When obtaining samples for population genetic studies, it is essential that the sampling is random. For Drosophila, one of the crucial steps in sampling experimental flies is the collection of eggs. Here an egg collection method is presented, which randomizes the eggs in a water column and diminishes environmental variance. This method was compared with a traditional egg collection method where eggs are collected directly from the medium. Within each method the observed and expected standard deviations of egg-to-adult viability were compared, whereby the difference in the randomness of the samples between the two methods was assessed. The method presented here was superior to the traditional method. Only 14% of the samples had a standard deviation higher than expected, as compared with 58% in the traditional method. To reduce bias in the estimation of the variance and the mean of a trait and to obtain a representative collection of genotypes, the method presented here is strongly recommended when collecting eggs from Drosophila.

  12. Development and Evaluation of a Micro- and Nanoscale Proteomic Sample Preparation Method

    SciTech Connect

    Wang, Haixing H.; Qian, Weijun; Mottaz, Heather M.; Clauss, Therese R.W.; Anderson, David J.; Moore, Ronald J.; Camp, David G.; Khan, Arshad H.; Sforza, Daniel M.; Pallavicini, Maria; Smith, Desmond J.; Smith, Richard D.

    2005-10-05

    Efficient and effective sample preparation of micro- and nano-scale (micro- and nano-gram) clinical specimens for proteomic applications is often difficult due to losses during the processing steps. Herein we describe a simple “single-tube” preparation protocol appropriate for small proteomic samples using the organic co-solvent, trifluoroethanol (TFE). TFE facilitates both protein extraction and protein denaturation without requiring a separate cleanup step, thus minimizing sample loss. The performance of the TFE method was initially evaluated by comparing to traditional detergent-based methods on relatively large scale sample processing using human breast cancer cells and mouse brain tissue. The results demonstrated that the TFE protocol provided comparable results to the traditional detergent-based protocols for larger samples (milligrams), based on both sample recovery and peptide/protein identification. The effectiveness of this protocol for micro- and nano-scale sample processing was then evaluated for the extraction of proteins/peptides and shown effective for small mouse brain tissue samples (~ 20 μg total protein content) and also for samples of ~ 5 000 human breast cancer MCF-7 cells (~ 500 ng total protein content), where the detergent-based methods were ineffective due to losses during cleanup and transfer steps.

  13. A venue-based method for sampling hard-to-reach populations.

    PubMed

    Muhib, F B; Lin, L S; Stueve, A; Miller, R L; Ford, W L; Johnson, W D; Smith, P J

    2001-01-01

    Constructing scientifically sound samples of hard-to-reach populations, also known as hidden populations, is a challenge for many research projects. Traditional sample survey methods, such as random sampling from telephone or mailing lists, can yield low numbers of eligible respondents while non-probability sampling introduces unknown biases. The authors describe a venue-based application of time-space sampling (TSS) that addresses the challenges of accessing hard-to-reach populations. The method entails identifying days and times when the target population gathers at specific venues, constructing a sampling frame of venue, day-time units (VDTs), randomly selecting and visiting VDTs (the primary sampling units), and systematically intercepting and collecting information from consenting members of the target population. This allows researchers to construct a sample with known properties, make statistical inference to the larger population of venue visitors, and theorize about the introduction of biases that may limit generalization of results to the target population. The authors describe their use of TSS in the ongoing Community Intervention Trial for Youth (CITY) project to generate a systematic sample of young men who have sex with men. The project is an ongoing community level HIV prevention intervention trial funded by the Centers for Disease Control and Prevention. The TSS method is reproducible and can be adapted to hard-to-reach populations in other situations, environments, and cultures.

  14. A venue-based method for sampling hard-to-reach populations.

    PubMed Central

    Muhib, F. B.; Lin, L. S.; Stueve, A.; Miller, R. L.; Ford, W. L.; Johnson, W. D.; Smith, P. J.

    2001-01-01

    Constructing scientifically sound samples of hard-to-reach populations, also known as hidden populations, is a challenge for many research projects. Traditional sample survey methods, such as random sampling from telephone or mailing lists, can yield low numbers of eligible respondents while non-probability sampling introduces unknown biases. The authors describe a venue-based application of time-space sampling (TSS) that addresses the challenges of accessing hard-to-reach populations. The method entails identifying days and times when the target population gathers at specific venues, constructing a sampling frame of venue, day-time units (VDTs), randomly selecting and visiting VDTs (the primary sampling units), and systematically intercepting and collecting information from consenting members of the target population. This allows researchers to construct a sample with known properties, make statistical inference to the larger population of venue visitors, and theorize about the introduction of biases that may limit generalization of results to the target population. The authors describe their use of TSS in the ongoing Community Intervention Trial for Youth (CITY) project to generate a systematic sample of young men who have sex with men. The project is an ongoing community level HIV prevention intervention trial funded by the Centers for Disease Control and Prevention. The TSS method is reproducible and can be adapted to hard-to-reach populations in other situations, environments, and cultures. PMID:11889287

  15. Aerostat-lofted instrument and sampling method for determination of emissions from open area sources

    EPA Science Inventory

    An aerostat-borne instrument and sampling method was developed to characterize air samples from area sources, such as emissions from open burning. The 10 kg battery-powered instrument system, termed "the Flyer," is lofted with a helium-filled aerostat of 4 m nominal diameter and ...

  16. 46 CFR 160.010-7 - Methods of sampling, inspections and tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... manufacturer— (1) Uses the same plastic buoyancy foam used in previous production lots, (2) Determines that the... Vessels § 160.010-7 Methods of sampling, inspections and tests. (a) General. Production tests must be... by the Commandant (CG-ENG-4). (b) Sampling of production lots. A production lot must consist of...

  17. 46 CFR 160.010-7 - Methods of sampling, inspections and tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... manufacturer— (1) Uses the same plastic buoyancy foam used in previous production lots, (2) Determines that the... Vessels § 160.010-7 Methods of sampling, inspections and tests. (a) General. Production tests must be... by the Commandant (CG-ENG-4). (b) Sampling of production lots. A production lot must consist of...

  18. GROUND WATER MONITORING AND SAMPLING: MULTI-LEVEL VERSUS TRADITIONAL METHODS WHATS WHAT?

    EPA Science Inventory

    After years of research and many publications, the question still remains: What is the best method to collect representative ground water samples from monitoring wells? Numerous systems and devices are currently available for obtaining both multi-level samples as well as traditi...

  19. Drying and storage methods affect cyfluthrin concentrations in exposed plant samples

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Standard procedures exist for collection and chemical analyses of pyrethroid insecticides in environmental matrices. However, less detail is given for drying and potential storage methods of plant samples prior to analyses. Due to equipment and financial limitations, immediate sample analysis is n...

  20. Design Study of Methods for Sampling Migrant and Seasonal Farm Workers. Final Report.

    ERIC Educational Resources Information Center

    Kalsbeek, William D.; Parker, Rebecca Robin

    This report describes efforts to develop sampling methods to be used in national or regional studies of migrant and seasonal farm workers (MSFWs). Several facets of the MSFWs' lifestyle create sampling difficulties. One is mobility. Although the dynamic nature of MSFWs' movement is partly understood, it is sufficiently unpredictable to create…

  1. Method and apparatus for measuring the NMR spectrum of an orientationally disordered sample

    DOEpatents

    Pines, Alexander; Samoson, Ago

    1990-01-01

    An improved NMR probe and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise oreintationally disordered samples. The apparatus mechanically varies the orientation of the sample such that the time average of two or more sets of spherical harmonic functions is zero.

  2. The "Closed School-Cluster" Method of Selecting a Probability Sample.

    ERIC Educational Resources Information Center

    Shaycoft, Marion F.

    In some educational research studies--particularly longitudinal studies requiring a probability sample of schools and spanning a wide range of grades--it is desirable to so select the sample that schools at different levels (e.g., elementary and secondary) "correspond." This has often proved unachievable, using standard methods of selecting school…

  3. Short communication: appropriate and alternative methods to determine viable bacterial counts in cow milk samples.

    PubMed

    Loss, G; Apprich, S; Kneifel, W; von Mutius, E; Genuneit, J; Braun-Fahrländer, C

    2012-06-01

    Farm milk consumption is reported to be inversely related to the development of asthma and atopy in children and it has been hypothesized that microorganisms in milk might contribute to this protective effect. The GABRIEL study was designed to investigate this hypothesis in a large population of European children, calling for a rapid alternative to classical culture techniques to determine bacteriological properties of milk samples. One objective was to evaluate 2 different rapid methods to determine bacteriological properties in a large number of cow milk samples collected under field conditions. BactoScan (Foss Analytical, Hillerød, Denmark), an automated standard flow cytometric method utilized for routine testing of milk quality, and TEMPO (bioMérieux, Marcy l'Etoile, France), an automated most-probable-number method, were used to assess the total viable bacterial count in farm and commercial milk samples. Both methods were compared with standard plate count method and each other. Measurements based on the TEMPO method were in good agreement with the standard plate count method and showed reliable results, whereas BactoScan results did not correlate with standard plate count measurements and yielded higher bacteria counts in heat-treated milk samples compared with raw milk samples. Most likely, these discrepant results were due to inferences with staining reactions and detection of bacteria in heat-treated milk samples. We conclude that, in contrast to the routinely used BactoScan method, the TEMPO method is an inexpensive and rapid alternative to standard culture methods suitable to assess total bacterial counts in processed and raw milk samples.

  4. Applicability of Demirjian's four methods and Willems method for age estimation in a sample of Turkish children.

    PubMed

    Akkaya, Nursel; Yilanci, Hümeyra Özge; Göksülük, Dinçer

    2015-09-01

    The aim of this study was to evaluate applicability of five dental methods including Demirjian's original, revised, four teeth, and alternate four teeth methods and Willems method for age estimation in a sample of Turkish children. Panoramic radiographs of 799 children (412 females, 387 males) aged between 2.20 and 15.99years were examined by two observers. A repeated measures ANOVA was performed to compare dental methods among gender and age groups. All of the five methods overestimated the chronological age on the average. Among these, Willems method was found to be the most accurate method, which showed 0.07 and 0.15years overestimation for males and females, respectively. It was followed by Demirjian's four teeth methods, revised and original methods. According to the results, Willems method can be recommended for dental age estimation of Turkish children in forensic applications.

  5. Field Methods and Sample Collection Techniques for the Surveillance of West Nile Virus in Avian Hosts.

    PubMed

    Wheeler, Sarah S; Boyce, Walter M; Reisen, William K

    2016-01-01

    Avian hosts play an important role in the spread, maintenance, and amplification of West Nile virus (WNV). Avian susceptibility to WNV varies from species to species thus surveillance efforts can focus both on birds that survive infection and those that succumb. Here we describe methods for the collection and sampling of live birds for WNV antibodies or viremia, and methods for the sampling of dead birds. Target species and study design considerations are discussed. PMID:27188560

  6. A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples

    NASA Technical Reports Server (NTRS)

    Carr, R. H.; Bustin, R.; Gibson, E. K.

    1987-01-01

    A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

  7. Sample preparation method for glass welding by ultrashort laser pulses yields higher seam strength

    SciTech Connect

    Cvecek, K.; Miyamoto, I.; Strauss, J.; Wolf, M.; Frick, T.; Schmidt, M.

    2011-05-01

    Glass welding by ultrashort laser pulses allows joining without the need of an absorber or a preheating and postheating process. However, cracks generated during the welding process substantially impair the joining strength of the welding seams. In this paper a sample preparation method is described that prevents the formation of cracks. The measured joining strength of samples prepared by this method is substantially higher than previously reported values.

  8. Mitochondrial Respiration Chain Enzymatic Activities in the Human Brain: Methodological Implications for Tissue Sampling and Storage.

    PubMed

    Ronsoni, Marcelo Fernando; Remor, Aline Pertile; Lopes, Mark William; Hohl, Alexandre; Troncoso, Iris H Z; Leal, Rodrigo Bainy; Boos, Gustavo Luchi; Kondageski, Charles; Nunes, Jean Costa; Linhares, Marcelo Neves; Lin, Kátia; Latini, Alexandra Susana; Walz, Roger

    2016-04-01

    Mitochondrial respiratory chain complexes enzymatic (MRCCE) activities were successfully evaluated in frozen brain samples. Epilepsy surgery offers an ethical opportunity to study human brain tissue surgically removed to treat drug resistant epilepsies. Epilepsy surgeries are done with hemodynamic and laboratory parameters to maintain physiology, but there are no studies analyzing the association among these parameters and MRCCE activities in the human brain tissue. We determined the intra-operative parameters independently associated with MRCCE activities in middle temporal neocortex (Cx), amygdala (AMY) and head of hippocampus (HIP) samples of patients (n = 23) who underwent temporal lobectomy using multiple linear regressions. MRCCE activities in Cx, AMY and HIP are differentially associated to trans-operative mean arterial blood pressure, O2 saturation, hemoglobin, and anesthesia duration to time of tissue sampling. The time-course between the last seizure occurrence and tissue sampling as well as the sample storage to biochemical assessments were also associated with enzyme activities. Linear regression models including these variables explain 13-17 % of MRCCE activities and show a moderate to strong effect (r = 0.37-0.82). Intraoperative hemodynamic and laboratory parameters as well as the time from last seizure to tissue sampling and storage time are associated with MRCCE activities in human samples from the Cx, AMYG and HIP. Careful control of these parameters is required to minimize confounding biases in studies using human brain samples collected from elective neurosurgery. PMID:26586405

  9. Metrological activity determination of 133Ba by sum-peak absolute method

    NASA Astrophysics Data System (ADS)

    da Silva, R. L.; de Almeida, M. C. M.; Delgado, J. U.; Poledna, R.; Santos, A.; de Veras, E. V.; Rangel, J.; Trindade, O. L.

    2016-07-01

    The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not. The activity is obtained directly with good accuracy and low uncertainties. 133Ba is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods don't calibrate 133Ba due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes 133Ba samples. Uncertainties lower than 1% to activity results were obtained.

  10. A charcoal sampling method and a gas chromatographic analytical procedure for carbon disulfide.

    PubMed

    McCammon, C S; Quinn, P M; Kupel, R E

    1975-08-01

    Research is reported concerning an acceptable method for sampling and analyzing samples for carbon disulfide. Test atmospheres of carbon disulfide were generated dynamically using the syringe injection method, ant the theoretical concetnration verified by a liquid absorbent, colorimetric method. The CS2 was adsorbed on charcoal tubes, eluted with benzene, and quantitated with a gas chromatography equipped with a sulfer flame photometric detector. The results compared with the colorimetris analysis. The sensitivity of this method is 1 mug on a charcoal tube. The charcoal tubes were also tested for breakthrough volumes, holding power vs time, and the effect of air transport and temperature cycles.

  11. Sampling and analysis method for measuring airborne coal dust mass in mixtures with limestone (rock) dust.

    PubMed

    Barone, T L; Patts, J R; Janisko, S J; Colinet, J F; Patts, L D; Beck, T W; Mischler, S E

    2016-01-01

    Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine.

  12. [Determination of mercury and copper in water samples by activation analysis using preconcentration on emission spectroscopic carbon powder (author's transl)].

    PubMed

    Nagatsuka, S; Tanizaki, Y

    1978-07-01

    A simple preconcentration procedure for mercury and copper was examined in the activation analysis of water samples. The preconcentration using pure activated carbon has been reported in several papers. The authors found that the carbon powder for emission spectroscopic analysis showed the high purity equivalent to pure activated carbon. The influence of various parameters in adsorption conditions was studied by radioactive tracers 197Hg and 64Cu. It was confirmed that 100% of these elements were adsorbed on carbon powders as pyrrolidine dithiocarbonate complexes at an acidity of pH 6--8, the temperature of 50 degrees C and the stirring time of 30 minutes. This method was applied to the activation analysis of the river water samples taken from the upper stream area of the Arakawa river and the ground water samples taken from the upper stream area of the Arakawa river and the ground water samples taken from the wells of the environs of Tokyo Megapolis. The carbon powders which adsorbed these elements were filtered, dried and analyzed by instrumental neutron activation analysis. The Hg concentrations of 0.01--0.1 ppb in river water and 0.03--1.4 ppb in ground water were obtained as well as the Cu concentrations of 0.3--3.0 ppb in ground water. The limits of determination of this method are 0.01 ppb Hg and 0.2 ppb Cu in the case of 11 sample of fresh water. PMID:704956

  13. Development of a new catalase activity assay for biological samples using optical CUPRAC sensor

    NASA Astrophysics Data System (ADS)

    Bekdeşer, Burcu; Özyürek, Mustafa; Güçlü, Kubilay; Alkan, Fulya Üstün; Apak, Reşat

    2014-11-01

    A novel catalase activity assay was developed for biological samples (liver and kidney tissue homogenates) using a rapid and low-cost optical sensor-based ‘cupric reducing antioxidant capacity' (CUPRAC) method. The reagent, copper(II)-neocuproine (Cu(II)-Nc) complex, was immobilized onto a cation-exchanger film of Nafion, and the absorbance changes associated with the formation of the highly-colored Cu(I)-Nc chelate as a result of reaction with hydrogen peroxide (H2O2) was measured at 450 nm. When catalase was absent, H2O2 produced the CUPRAC chromophore, whereas catalase, being an effective H2O2 scavenger, completely annihilated the CUPRAC signal due to H2O2. Thus, the CUPRAC absorbance due to H2O2 oxidation concomitant with Cu(I)-Nc formation decreased proportionally with catalase. The developed sensor gave a linear response over a wide concentration range of H2O2 (0.68-78.6 μM). This optical sensor-based method applicable to tissue homogenates proved to be efficient for low hydrogen peroxide concentrations (physiological and nontoxic levels) to which the widely used UV method is not accurately responsive. Thus, conventional problems of the UV method arising from relatively low sensitivity and selectivity, and absorbance disturbance due to gaseous oxygen evolution were overcome. The catalase findings of the proposed method for tissue homogenates were statistically alike with those of HPLC.

  14. Development of a new catalase activity assay for biological samples using optical CUPRAC sensor.

    PubMed

    Bekdeşer, Burcu; Özyürek, Mustafa; Güçlü, Kubilay; Alkan, Fulya Üstün; Apak, Reşat

    2014-11-11

    A novel catalase activity assay was developed for biological samples (liver and kidney tissue homogenates) using a rapid and low-cost optical sensor-based 'cupric reducing antioxidant capacity' (CUPRAC) method. The reagent, copper(II)-neocuproine (Cu(II)-Nc) complex, was immobilized onto a cation-exchanger film of Nafion, and the absorbance changes associated with the formation of the highly-colored Cu(I)-Nc chelate as a result of reaction with hydrogen peroxide (H2O2) was measured at 450 nm. When catalase was absent, H2O2 produced the CUPRAC chromophore, whereas catalase, being an effective H2O2 scavenger, completely annihilated the CUPRAC signal due to H2O2. Thus, the CUPRAC absorbance due to H2O2 oxidation concomitant with Cu(I)-Nc formation decreased proportionally with catalase. The developed sensor gave a linear response over a wide concentration range of H2O2 (0.68-78.6 μM). This optical sensor-based method applicable to tissue homogenates proved to be efficient for low hydrogen peroxide concentrations (physiological and nontoxic levels) to which the widely used UV method is not accurately responsive. Thus, conventional problems of the UV method arising from relatively low sensitivity and selectivity, and absorbance disturbance due to gaseous oxygen evolution were overcome. The catalase findings of the proposed method for tissue homogenates were statistically alike with those of HPLC.

  15. A neutron multiplicity analysis method for uranium samples with liquid scintillators

    NASA Astrophysics Data System (ADS)

    Zhou, Hao; Lin, Hongtao; Liu, Guorong; Li, Jinghuai; Liang, Qinglei; Zhao, Yonggang

    2015-10-01

    A new neutron multiplicity analysis method for uranium samples with liquid scintillators is introduced. An active well-type fast neutron multiplicity counter has been built, which consists of four BC501A liquid scintillators, a n/γdiscrimination module MPD-4, a multi-stop time to digital convertor MCS6A, and two Am-Li sources. A mathematical model is built to symbolize the detection processes of fission neutrons. Based on this model, equations in the form of R=F*P*Q*T could be achieved, where F indicates the induced fission rate by interrogation sources, P indicates the transfer matrix determined by multiplication process, Q indicates the transfer matrix determined by detection efficiency, T indicates the transfer matrix determined by signal recording process and crosstalk in the counter. Unknown parameters about the item are determined by the solutions of the equations. A 252Cf source and some low enriched uranium items have been measured. The feasibility of the method is proven by its application to the data analysis of the experiments.

  16. Sample preparation method for isolation of single-cell types from mouse liver for proteomic studies.

    PubMed

    Liu, Wei; Hou, Yufang; Chen, Huahai; Wei, Handong; Lin, Weiran; Li, Jichang; Zhang, Ming; He, Fuchu; Jiang, Ying

    2011-09-01

    It becomes increasingly clear that separation of pure cell populations provides a uniquely sensitive and accurate approach to protein profiling in biological systems and opens up a new area for proteomic analysis. The method we described could simultaneously isolate population of hepatocytes (HCs), hepatic stellate cells (HSCs), Kupffer cells (KCs) and liver sinusoidal endothelial cells (LSECs) by a combination of collagenase-based density gradient centrifugation and magnetic activated cell sorting with high purity and yield for the first time. More than 98% of the isolated HCs were positive for cytokeratin 18, with a viability of 91%. Approximately 97% of the isolated HSCs expressed glial fibrillary acidic protein with a viability of 95%. Nearly 98% of isolated KCs expressed F4/80 with a viability of 94%. And the purity of LSECs reached up to 91% with a viability of 94%. And yield for HCs, HSCs, LSECs and KCs were 6.3, 1.3, 2.6 and 5.0 million per mouse. This systematic isolation method enables us to study the proteome profiling of different types of liver cells with high purity and yield, which is especially useful for sample preparation of Human Liver Proteome Project.

  17. Use of quantitative PCR to evaluate methods of bacteria sampling in periodontal patients.

    PubMed

    Masunaga, Hiroshi; Tsutae, Wataru; Oh, Hyun; Shinozuka, Naoki; Kishimoto, Noriyoshi; Ogata, Yorimasa

    2010-12-01

    Periodontal disease is associated with specific periodontal pathogens and may persist as gingivitis or progress to more severe disease. The bacteria involved in disease initiation and progression have not been identified. We used quantitative polymerase chain reaction (PCR) to compare the levels of Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola, and total bacteria detected by different sampling methods. On the basis of the results of clinical examinations, 57 patients were divided into 3 groups: healthy group (group A), gingivitis group (group B), and periodontitis group (group C). Bacterial samples were collected from saliva, mouthwash, and by paper-point sampling of gingival crevicular fluid (GCF), and the samples were analyzed with quantitative PCR targeting 16S rRNA. The numbers of total bacteria in samples of GCF, saliva, and mouthwash were 10⁵ to 10⁶, 10⁸, and 10⁷, respectively, per milliliter. The number of P. gingivalis in GCF samples was lower than 10 in group A; however, in groups B and C, the values were 10³ and 10⁴, respectively, indicating that the number of P. gingivalis increased with worsening clinical status. Findings were similar in the samples of saliva and mouthwash. The numbers of T. forsythia showed a pattern similar to that of P. gingivalis in all 3 samples. These results suggest that saliva and mouthwash samples are clinically useful for bacterial testing of periodontal diseases by quantitative PCR. In addition, mouthwash sampling is more feasible and straightforward than saliva sampling.

  18. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    SciTech Connect

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2015-09-29

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  19. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  20. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    SciTech Connect

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2014-06-03

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.