Personnel Dose Assessment during Active Interrogation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Thomas Martin; Akkurt, Hatice; Patton, Bruce W
A leading candidate in the detection of special nuclear material (SNM) is active interrogation (AI). Unlike passive interrogation, AI uses a source to enhance or create a detectable signal from SNM (usually fission), particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. During the development of AI sources, significant effort is put into determining the source strength required to detect SNM in specific scenarios. Usually during this process, but not always, an evaluation of personnel dosemore » is also completed. In this instance personnel dose could involve any of the following: (1) personnel performing the AI; (2) unknown stowaways who are inside the object being interrogated; or (3) in clandestine interrogations, personnel who are known to be inside the object being interrogated but are unaware of the interrogation. In most instances, dose to anyone found smuggling SNM will be a secondary issue. However, for the organizations performing the AI, legal if not moral considerations should make dose to the personnel performing the AI, unknown stowaways, or innocent bystanders in clandestine interrogations a serious concern.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Thomas Martin; Patton, Bruce W
The detection and interdiction of special nuclear material (SNM) is still a high-priority focus area for many organizations around the world. One method that is commonly considered a leading candidate in the detection of SNM is active interrogation (AI). AI is different from its close relative, passive interrogation, in that an active source is used to enhance or create a detectable signal (usually fission) from SNM, particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. Inmore » this work the signal from prompt neutrons and photons as well as delayed neutrons and photons will be combined, as is typically done in AI. In previous work AI has been evaluated experimentally and computationally. However, for the purposes of this work, past scenarios are considered lightly shielded and tightly coupled spatially. At most, the previous work interrogated the contents of one standard cargo container (2.44 x 2.60 x 6.10 m) and the source and detector were both within a few meters of the object being interrogated. A few examples of this type of previous work can be found in references 1 and 2. Obviously, more heavily shielded AI scenarios will require larger source intensities, larger detector surface areas (larger detectors or more detectors), greater detector efficiencies, longer count times, or some combination of these.« less
Hybrid Monte Carlo/Deterministic Methods for Accelerating Active Interrogation Modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peplow, Douglas E.; Miller, Thomas Martin; Patton, Bruce W
2013-01-01
The potential for smuggling special nuclear material (SNM) into the United States is a major concern to homeland security, so federal agencies are investigating a variety of preventive measures, including detection and interdiction of SNM during transport. One approach for SNM detection, called active interrogation, uses a radiation source, such as a beam of neutrons or photons, to scan cargo containers and detect the products of induced fissions. In realistic cargo transport scenarios, the process of inducing and detecting fissions in SNM is difficult due to the presence of various and potentially thick materials between the radiation source and themore » SNM, and the practical limitations on radiation source strength and detection capabilities. Therefore, computer simulations are being used, along with experimental measurements, in efforts to design effective active interrogation detection systems. The computer simulations mostly consist of simulating radiation transport from the source to the detector region(s). Although the Monte Carlo method is predominantly used for these simulations, difficulties persist related to calculating statistically meaningful detector responses in practical computing times, thereby limiting their usefulness for design and evaluation of practical active interrogation systems. In previous work, the benefits of hybrid methods that use the results of approximate deterministic transport calculations to accelerate high-fidelity Monte Carlo simulations have been demonstrated for source-detector type problems. In this work, the hybrid methods are applied and evaluated for three example active interrogation problems. Additionally, a new approach is presented that uses multiple goal-based importance functions depending on a particle s relevance to the ultimate goal of the simulation. Results from the examples demonstrate that the application of hybrid methods to active interrogation problems dramatically increases their calculational efficiency.« less
NASA Astrophysics Data System (ADS)
Keith, Rodney Lyman
Intermodal shipping containers entering the United States provide an avenue to smuggle unsecured or stolen special nuclear material (SNM). The only direct method fielded to indicate the presence of SNM is by passive photon/neutron radiation detection. Active interrogation using neutral particle beams to induce fission in SNM is a method under consideration. One by-product of fission is the creation of fragments that undergo radioactive decay over a time period on the order of tens of seconds after the initial event. The "delayed" gamma-rays emitted from these fragments over this period are considered a hallmark for the presence of SNM. A fundamental model is developed using homogenized cargos with a SNM target embedded at the center and computationally interrogated using simultaneous neutron and photon beams. Findings from analysis of the delayed gamma emissions from these experiments are intended to mitigate the effects of poor quality information about the composition and disposition of suspect cargo before examination in an active interrogation portal.
Design and Fabrication of Cherenkov Counters for the Detection of SNM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Anna S.; Lanza, Richard; Galaitsis, Anthony
2011-12-13
The need for large-size detectors for long-range active interrogation (AI) detection of SNM has generated interest in water-based detector technologies. Water Cherenkov Detectors (WCD) were selected for this research because of their transportability, scalability, and an inherent energy threshold. The detector design and analysis was completed using the Geant4 toolkit. It was demonstrated both computationally and experimentally that it is possible to use WCD to detect and characterize gamma rays. Absolute efficiency of the detector (with no energy cuts applied) was determined to be around 30% for a {sup 60}Co source.
Computational Age Dating of Special Nuclear Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2012-06-30
This slide-show presented an overview of the Constrained Progressive Reversal (CPR) method for computing decays, age dating, and spoof detecting. The CPR method is: Capable of temporal profiling a SNM sample; Precise (compared with known decay code, such a ORIGEN); Easy (for computer implementation and analysis). We have illustrated with real SNM data using CPR for age dating and spoof detection. If SNM is pure, may use CPR to derive its age. If SNM is mixed, CPR will indicate that it is mixed or spoofed.
Detectors for Active Interrogation Applications
NASA Astrophysics Data System (ADS)
Clarke, S. D.; Hamel, M. C.; Bourne, M. M.; Pozzi, S. A.
Active interrogation creates an environment that is particularly challenging from a radiation-detection standpoint: the elevated background levels from the source can mask the desired signatures from the SNM. Neutron based interrogation experiments have shown that nanosecond-level timing is required to discriminate induced-fission neutrons from the scattered source neutrons. Previous experiments using high-energy bremsstrahlung X-rays have demonstrated the ability to induce and detect prompt photofission neutrons from single target materials; however, a real-world application would require spectroscopic capability to discern between photofission neutrons emitted by SNM and neutrons emitted by other reactions in non-SNM. Using digital pulse-shape discrimination, organic liquid scintillators are capable of reliably detecting neutrons in an intense gamma-ray field. Photon misclassification rates as low as 1 in 106 have been achieved, which is approaching the level of gaseous neutron detectors such as 3He without the need for neutron moderation. These scintillators also possess nanosecond-timing resolution, making them candidates for both neutron-and photon-driven active interrogation systems. We have applied an array of liquid and NaI(Tl) scintillators to successfully image 13.7 kg of HEU interrogated by a DT neutron generator; the system was in the direct presence of the accelerator during the experiment.
Cephalosporins inhibit human metallo β-lactamase fold DNA repair nucleases SNM1A and SNM1B/apollo.
Lee, Sook Y; Brem, Jürgen; Pettinati, Ilaria; Claridge, Timothy D W; Gileadi, Opher; Schofield, Christopher J; McHugh, Peter J
2016-05-10
Bacterial metallo-β-lactamases (MBLs) are involved in resistance to β-lactam antibiotics including cephalosporins. Human SNM1A and SNM1B are MBL superfamily exonucleases that play a key role in the repair of DNA interstrand cross-links, which are induced by antitumour chemotherapeutics, and are therefore targets for cancer chemosensitization. We report that cephalosporins are competitive inhibitors of SNM1A and SNM1B exonuclease activity; both the intact β-lactam and their hydrolysed products are active. This discovery provides a lead for the development of potent and selective SNM1A and SNM1B inhibitors.
Allerston, Charles K.; Lee, Sook Y.; Newman, Joseph A.; Schofield, Christopher J.; McHugh, Peter J.; Gileadi, Opher
2015-01-01
The human SNM1A and SNM1B/Apollo proteins are members of an extended family of eukaryotic nuclease containing a motif related to the prokaryotic metallo-β-lactamase (MBL) fold. SNM1A is a key exonuclease during replication-dependent and transcription-coupled interstrand crosslink repair, while SNM1B/Apollo is required for maintaining telomeric overhangs. Here, we report the crystal structures of SNM1A and SNM1B at 2.16 Å. While both proteins contain a typical MBL-β-CASP domain, a region of positive charge surrounds the active site of SNM1A, which is absent in SNM1B and explains the greater apparent processivity of SNM1A. The structures of both proteins also reveal a putative, wide DNA-binding groove. Extensive mutagenesis of this groove, coupled with detailed biochemical analysis, identified residues that did not impact on SNM1A catalytic activity, but drastically reduced its processivity. Moreover, we identified a key role for this groove for efficient digestion past DNA interstrand crosslinks, facilitating the key DNA repair reaction catalysed by SNM1A. Together, the architecture and dimensions of this groove, coupled to the surrounding region of high positive charge, explain the remarkable ability of SNM1A to accommodate and efficiently digest highly distorted DNA substrates, such as those containing DNA lesions. PMID:26582912
SNM-DAT: Simulation of a heterogeneous network for nuclear border security
NASA Astrophysics Data System (ADS)
Nemzek, R.; Kenyon, G.; Koehler, A.; Lee, D. M.; Priedhorsky, W.; Raby, E. Y.
2007-08-01
We approach the problem of detecting Special Nuclear Material (SNM) smuggling across open borders by modeling a heterogeneous sensor network using an agent-based simulation. Our simulation SNM Data Analysis Tool (SNM-DAT) combines fixed seismic, metal, and radiation detectors with a mobile gamma spectrometer. Decision making within the simulation determines threat levels by combined signatures. The spectrometer is a limited-availability asset, and is only deployed for substantial threats. "Crossers" can be benign or carrying shielded SNM. Signatures and sensors are physics based, allowing us to model realistic sensor networks. The heterogeneous network provides great gains in detection efficiency compared to a radiation-only system. We can improve the simulation through better sensor and terrain models, additional signatures, and crossers that mimic actual trans-border traffic. We expect further gains in our ability to design sensor networks as we learn the emergent properties of heterogeneous detection, and potential adversary responses.
Detectors for Active Interrogation Applications
Clarke, S. D.; Hamel, M. C.; Bourne, M. M.; ...
2017-10-26
Active interrogation creates an environment that is particularly challenging from a radiation-detection standpoint: the elevated background levels from the source can mask the desired signatures from the SNM. Neutron based interrogation experiments have shown that nanosecond-level timing is required to discriminate induced-fission neutrons from the scattered source neutrons. Previous experiments using high-energy bremsstrahlung X-rays have demonstrated the ability to induce and detect prompt photofission neutrons from single target materials; however, a real-world application would require spectroscopic capability to discern between photofission neutrons emitted by SNM and neutrons emitted by other reactions in non-SNM. Using digital pulseshape discrimination, organic liquid scintillatorsmore » are capable of reliably detecting neutrons in an intense gamma-ray field. Photon misclassification rates as low as 1 in 10 6 have been achieved, which is approaching the level of gaseous neutron detectors such as 3He without the need for neutron moderation. These scintillators also possess nanosecond-timing resolution, making them candidates for both neutron-and photon-driven active interrogation systems. Lastly, we have applied an array of liquid and NaI(Tl) scintillators to successfully image 13.7 kg of HEU interrogated by a DT neutron generator; the system was in the direct presence of the accelerator during the experiment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clarke, S. D.; Hamel, M. C.; Bourne, M. M.
Active interrogation creates an environment that is particularly challenging from a radiation-detection standpoint: the elevated background levels from the source can mask the desired signatures from the SNM. Neutron based interrogation experiments have shown that nanosecond-level timing is required to discriminate induced-fission neutrons from the scattered source neutrons. Previous experiments using high-energy bremsstrahlung X-rays have demonstrated the ability to induce and detect prompt photofission neutrons from single target materials; however, a real-world application would require spectroscopic capability to discern between photofission neutrons emitted by SNM and neutrons emitted by other reactions in non-SNM. Using digital pulseshape discrimination, organic liquid scintillatorsmore » are capable of reliably detecting neutrons in an intense gamma-ray field. Photon misclassification rates as low as 1 in 10 6 have been achieved, which is approaching the level of gaseous neutron detectors such as 3He without the need for neutron moderation. These scintillators also possess nanosecond-timing resolution, making them candidates for both neutron-and photon-driven active interrogation systems. Lastly, we have applied an array of liquid and NaI(Tl) scintillators to successfully image 13.7 kg of HEU interrogated by a DT neutron generator; the system was in the direct presence of the accelerator during the experiment.« less
Allerston, Charles K; Lee, Sook Y; Newman, Joseph A; Schofield, Christopher J; McHugh, Peter J; Gileadi, Opher
2015-12-15
The human SNM1A and SNM1B/Apollo proteins are members of an extended family of eukaryotic nuclease containing a motif related to the prokaryotic metallo-β-lactamase (MBL) fold. SNM1A is a key exonuclease during replication-dependent and transcription-coupled interstrand crosslink repair, while SNM1B/Apollo is required for maintaining telomeric overhangs. Here, we report the crystal structures of SNM1A and SNM1B at 2.16 Å. While both proteins contain a typical MBL-β-CASP domain, a region of positive charge surrounds the active site of SNM1A, which is absent in SNM1B and explains the greater apparent processivity of SNM1A. The structures of both proteins also reveal a putative, wide DNA-binding groove. Extensive mutagenesis of this groove, coupled with detailed biochemical analysis, identified residues that did not impact on SNM1A catalytic activity, but drastically reduced its processivity. Moreover, we identified a key role for this groove for efficient digestion past DNA interstrand crosslinks, facilitating the key DNA repair reaction catalysed by SNM1A. Together, the architecture and dimensions of this groove, coupled to the surrounding region of high positive charge, explain the remarkable ability of SNM1A to accommodate and efficiently digest highly distorted DNA substrates, such as those containing DNA lesions. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Spectroscopic neutron detection using composite scintillators
NASA Astrophysics Data System (ADS)
Jovanovic, I.; Foster, A.; Kukharev, V.; Mayer, M.; Meddeb, A.; Nattress, J.; Ounaies, Z.; Trivelpiece, C.
2016-09-01
Shielded special nuclear material (SNM), especially highly enriched uranium, is exceptionally difficult to detect without the use of active interrogation (AI). We are investigating the potential use of low-dose active interrogation to realize simultaneous high-contrast imaging and photofission of SNM using energetic gamma-rays produced by low-energy nuclear reactions, such as 11B(d,nγ)12C and 12C(p,p‧)12C. Neutrons produced via fission are one reliable signature of the presence of SNM and are usually identified by their unique timing characteristics, such as the delayed neutron die-away. Fast neutron spectroscopy may provide additional useful discriminating characteristics for SNM detection. Spectroscopic measurements can be conducted by recoil-based or thermalization and capture-gated detectors; the latter may offer unique advantages since they facilitate low-statistics and event-by-event neutron energy measurements without spectrum unfolding. We describe the results of the development and characterization of a new type of capture-gated spectroscopic neutron detector based on a composite of scintillating polyvinyltoluene and lithium-doped scintillating glass in the form of millimeter-thick rods. The detector achieves >108 neutron-gamma discrimination resulting from its geometric properties and material selection. The design facilitates simultaneous pulse shape and pulse height discrimination, despite the fact that no materials intrinsically capable of pulse shape discrimination have been used to construct the detector. Accurate single-event measurements of neutron energy may be possible even when the energy is relatively low, such as with delayed fission neutrons. Simulation and preliminary measurements using the new composite detector are described, including those conducted using radioisotope sources and the low-dose active interrogation system based on low-energy nuclear reactions.
Wang, Junxiu; Xiong, Guoliang; Ma, Liang; Wang, Shihui; Zhou, Xu; Wang, Lei; Xiao, Lehui; Su, Xin; Yu, Changyuan
2017-08-15
Single-nucleotide mutation (SNM) has proven to be associated with a variety of human diseases. Development of reliable methods for the detection of SNM is crucial for molecular diagnosis and personalized medicine. The sandwich assays are widely used tools for detecting nucleic acid biomarkers due to their low cost and rapid signaling. However, the poor hybridization specificity of signal probe at room temperature hampers the discrimination of mutant and wild type. Here, we demonstrate a dynamic sandwich assay on magnetic beads for SNM detection based on the transient binding between signal probe and target. By taking the advantage of mismatch sensitive thermodynamics of transient DNA binding, the dynamic sandwich assay exhibits high discrimination factor for mutant with a broad range of salt concentration at room temperature. The beads used in this assay serve as a tool for separation, and might be helpful to enhance SNM selectivity. Flexible design of signal probe and facile magnetic separation allow multiple-mode downstream analysis including colorimetric detection and isothermal amplification. With this method, BRAF mutations in the genomic DNA extracted from cancer cell lines were tested, allowing sensitive detection of SNM at very low abundances (0.1-0.5% mutant/wild type). Copyright © 2017 Elsevier B.V. All rights reserved.
Multimodal Imaging Using a 11B(d,nγ)12C Source
NASA Astrophysics Data System (ADS)
Nattress, Jason; Rose, Paul; Mayer, Michal; Wonders, Marc; Wilhelm, Kyle; Erickson, Anna; Jovanovic, Igor; Multimodal Imaging; Nuclear Detection (MIND) in Active Interrogation Collaboration
2016-03-01
Detection of shielded special nuclear material (SNM) still remains one of the greatest challenges facing nuclear security, where small signal-to-background ratios result from complex, challenging configurations of practical objects. Passive detection relies on the spontaneous radioactive decay, whereas active interrogation (AI) uses external probing radiation to identify and characterize the material. AI provides higher signal intensity, providing a more viable method for SNM detection. New and innovative approaches are needed to overcome specific application constraints, such as limited scanning time. We report on a new AI approach that integrates both neutron and gamma transmission signatures to deduce specific material properties that can be utilized to aid SNM identification. The approach uses a single AI source, single detector type imaging system based on the 11B(d,nγ)12C reaction and an array of eight EJ-309 liquid scintillators, respectively. An integral transmission imaging approach has been employed initially for both neutrons and photons, exploiting the detectors' particle discrimination properties. Representative object images using neutrons and photons will be presented.
Wolter, R; Siede, W; Brendel, M
1996-02-05
The interstrand cross-link repair gene SNM1 of Saccharomyces cerevisiae was examined for regulation in response to DNA-damaging agents. Induction of SNM1-lacZ fusions was detected in response to nitrogen mustard, cis-platinum (II) diamine dichloride, UV light, and 8-methoxypsoralen + UVA, but not after heat-shock treatment or incubation with 2-dimethylaminoethylchloride, methylmethane sulfonate or 4-nitroquinoline-N-oxide. The promoter of SNM1 contains a 15 bp motif, which shows homology to the DRE2 box of the RAD2 promoter. Similar motifs have been found in promoter regions of other damage-inducible DNA repair genes. Deletion of this motif results in loss of inducibility of SNM1. Also, a putative negative upstream regulation sequence was found to be responsible for repression of constitutive transcription of SNM1. Surprisingly, no inducibility of SNM1 was found after treatment with DNA-damaging agents in strains without an intact DUN1 gene, while regulation seems unchanged in sad1 mutants.
NASA Astrophysics Data System (ADS)
Clemett, Ceri D.; Martin, Philip N.; Hill, Cassie; Threadgold, James R.; Maddock, Robert C.; Campbell, Ben; O'Malley, John; Woolf, Richard S.; Phlips, Bernard F.; Hutcheson, Anthony L.; Wulf, Eric A.; Zier, Jacob C.; Jackson, Stuart L.; Commisso, Robert J.; Schumer, Joseph W.
2015-04-01
Active interrogation is a method used to enhance the likelihood of detection of shielded special nuclear material (SNM); an external source of radiation is used to interrogate a target and to stimulate fission within any SNM present. Radiation produced by the fission process can be detected and used to infer the presence of the SNM. The Atomic Weapons Establishment (AWE) and the Naval Research Laboratory (NRL) have carried out a joint experimental study into the use of single pulse, high-intensity sources of bremsstrahlung x-rays and D(γb, n)H photoneutrons in an active interrogation system. The source was operated in both x-ray-only and mixed x-ray/photoneutron modes, and was used to irradiate a depleted uranium (DU) target which was enclosed by up to 150 g·cm - 2 of steel shielding. Resulting radiation signatures were measured by a suite of over 80 detectors and the data used to characterise detectable fission signatures as a function of the areal mass of the shielding. This paper describes the work carried out and discusses data collected with 3He proportional counters, NaI(Tl) scintillators and Eljen EJ-309 liquid scintillators. Results with the x-ray-only source demonstrate detection ( > 3\\sigmab) of the DU target through a minimum of 113 g·cm - 2 of steel, dropping to 85 g·cm- 2 when using a mixed x-ray/photoneutron source. The 3He proportional counters demonstrate detection ( > 3\\sigmab) of the DU target through the maximum 149. 7 g·cm - 2 steel shielding deployed for both photon and mixed x-ray/photoneutron sources.
Characterization of the human SNM1A and SNM1B/Apollo DNA repair exonucleases.
Sengerová, Blanka; Allerston, Charles K; Abu, Mika; Lee, Sook Y; Hartley, Janet; Kiakos, Konstantinos; Schofield, Christopher J; Hartley, John A; Gileadi, Opher; McHugh, Peter J
2012-07-27
Human SNM1A and SNM1B/Apollo have both been implicated in the repair of DNA interstrand cross-links (ICLs) by cellular studies, and SNM1B is also required for telomere protection. Here, we describe studies on the biochemical characterization of the SNM1A and SNM1B proteins. The results reveal some fundamental differences in the mechanisms of the two proteins. Both SNM1A and SNM1B digest double-stranded and single-stranded DNA with a 5'-to-3' directionality in a reaction that is stimulated by divalent cations, and both nucleases are inhibited by the zinc chelator o-phenanthroline. We find that SNM1A has greater affinity for single-stranded DNA over double-stranded DNA that is not observed with SNM1B. Although both proteins demonstrate a low level of processivity on low molecular weight DNA oligonucleotide substrates, when presented with high molecular weight DNA, SNM1A alone is rendered much more active, being capable of digesting kilobase-long stretches of DNA. Both proteins can digest past ICLs induced by the non-distorting minor groove cross-linking agent SJG-136, albeit with SNM1A showing a greater capacity to achieve this. This is consistent with the proposal that SNM1A and SNM1B might exhibit some redundancy in ICL repair. Together, our work establishes differences in the substrate selectivities of SNM1A and SNM1B that are likely to be relevant to their in vivo roles and which might be exploited in the development of selective inhibitors.
Characterization of the Human SNM1A and SNM1B/Apollo DNA Repair Exonucleases*
Sengerová, Blanka; Allerston, Charles K.; Abu, Mika; Lee, Sook Y.; Hartley, Janet; Kiakos, Konstantinos; Schofield, Christopher J.; Hartley, John A.; Gileadi, Opher; McHugh, Peter J.
2012-01-01
Human SNM1A and SNM1B/Apollo have both been implicated in the repair of DNA interstrand cross-links (ICLs) by cellular studies, and SNM1B is also required for telomere protection. Here, we describe studies on the biochemical characterization of the SNM1A and SNM1B proteins. The results reveal some fundamental differences in the mechanisms of the two proteins. Both SNM1A and SNM1B digest double-stranded and single-stranded DNA with a 5′-to-3′ directionality in a reaction that is stimulated by divalent cations, and both nucleases are inhibited by the zinc chelator o-phenanthroline. We find that SNM1A has greater affinity for single-stranded DNA over double-stranded DNA that is not observed with SNM1B. Although both proteins demonstrate a low level of processivity on low molecular weight DNA oligonucleotide substrates, when presented with high molecular weight DNA, SNM1A alone is rendered much more active, being capable of digesting kilobase-long stretches of DNA. Both proteins can digest past ICLs induced by the non-distorting minor groove cross-linking agent SJG-136, albeit with SNM1A showing a greater capacity to achieve this. This is consistent with the proposal that SNM1A and SNM1B might exhibit some redundancy in ICL repair. Together, our work establishes differences in the substrate selectivities of SNM1A and SNM1B that are likely to be relevant to their in vivo roles and which might be exploited in the development of selective inhibitors. PMID:22692201
78 FR 47009 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... action to submit an information collection request to the Office of Management and Budget (OMB) and... accounting programs and to confirm the absence of (or detect the occurrence of) SNM theft or diversion. NUREG...
Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong
2010-01-01
In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy. PMID:22163641
Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong
2010-01-01
In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.
Mason, Jennifer M; Das, Ishita; Arlt, Martin; Patel, Neil; Kraftson, Stephanie; Glover, Thomas W; Sekiguchi, JoAnn M
2013-12-15
SNM1B/Apollo is a DNA nuclease that has important functions in telomere maintenance and repair of DNA interstrand crosslinks (ICLs) within the Fanconi anemia (FA) pathway. SNM1B is required for efficient localization of key repair proteins, such as the FA protein, FANCD2, to sites of ICL damage and functions epistatically to FANCD2 in cellular survival to ICLs and homology-directed repair. The FA pathway is also activated in response to replication fork stalling. Here, we sought to determine the importance of SNM1B in cellular responses to stalled forks in the absence of a blocking lesion, such as ICLs. We found that depletion of SNM1B results in hypersensitivity to aphidicolin, a DNA polymerase inhibitor that causes replication stress. We observed that the SNM1B nuclease is required for efficient localization of the DNA repair proteins, FANCD2 and BRCA1, to subnuclear foci upon aphidicolin treatment, thereby indicating SNM1B facilitates direct repair of stalled forks. Consistent with a role for SNM1B subsequent to recognition of the lesion, we found that SNM1B is dispensable for upstream events, including activation of ATR-dependent signaling and localization of RPA, γH2AX and the MRE11/RAD50/NBS1 complex to aphidicolin-induced foci. We determined that a major consequence of SNM1B depletion is a marked increase in spontaneous and aphidicolin-induced chromosomal gaps and breaks, including breakage at common fragile sites. Thus, this study provides evidence that SNM1B functions in resolving replication stress and preventing accumulation of genomic damage.
NASA Astrophysics Data System (ADS)
Deyglun, Clément; Carasco, Cédric; Pérot, Bertrand
2014-06-01
The detection of Special Nuclear Materials (SNM) by neutron interrogation is extensively studied by Monte Carlo simulation at the Nuclear Measurement Laboratory of CEA Cadarache (French Alternative Energies and Atomic Energy Commission). The active inspection system is based on the Associated Particle Technique (APT). Fissions induced by tagged neutrons (i.e. correlated to an alpha particle in the DT neutron generator) in SNM produce high multiplicity coincidences which are detected with fast plastic scintillators. At least three particles are detected in a short time window following the alpha detection, whereas nonnuclear materials mainly produce single events, or pairs due to (n,2n) and (n,n'γ) reactions. To study the performances of an industrial cargo container inspection system, Monte Carlo simulations are performed with the MCNP-PoliMi transport code, which records for each neutron history the relevant information: reaction types, position and time of interactions, energy deposits, secondary particles, etc. The output files are post-processed with a specific tool developed with ROOT data analysis software. Particles not correlated with an alpha particle (random background), counting statistics, and time-energy resolutions of the data acquisition system are taken into account in the numerical model. Various matrix compositions, suspicious items, SNM shielding and positions inside the container, are simulated to assess the performances and limitations of an industrial system.
SNM1B/Apollo interacts with astrin and is required for the prophase cell cycle checkpoint.
Liu, Lingling; Akhter, Shamima; Bae, Jae-Bum; Mukhopadhyay, Sudit S; Richie, Christopher T; Liu, Xiaojun; Legerski, Randy
2009-02-15
Previously, we have shown that SNM1A is a multifunctional gene involved in both the DNA damage response and in an early mitotic checkpoint in response to spindle stress. Another member of the SNM1 gene family, SNM1B/Apollo, has been shown to have roles in both the response to DNA interstrand cross-linking agents and in telomere protection during S phase. Here, we demonstrate a novel role for SNM1B/Apollo in mitosis in response to spindle stress. SNM1B-deficient cells exhibit a defect in the prophase checkpoint. Loss of the prophase checkpoint induces an extended mitotic delay, which is due to prolonged activation of the spindle checkpoint. In addition, we show that SNM1B/Apollo interacts with the essential microtubule binding protein Astrin. SNM1B/Apollo interacts with Astrin through its conserved metallo-beta-lactamase domain, and disruption of this interaction by point mutations results in a deficient prophase checkpoint. These findings suggest that SNM1B/Apollo and Astrin function together to enforce the prophase checkpoint in response to spindle stress.
Detecting special nuclear material using muon-induced neutron emission
NASA Astrophysics Data System (ADS)
Guardincerri, Elena; Bacon, Jeffrey; Borozdin, Konstantin; Matthew Durham, J.; Fabritius, Joseph, II; Hecht, Adam; Milner, Edward C.; Miyadera, Haruo; Morris, Christopher L.; Perry, John; Poulson, Daniel
2015-07-01
The penetrating ability of cosmic ray muons makes them an attractive probe for imaging dense materials. Here, we describe experimental results from a new technique that uses neutrons generated by cosmic-ray muons to identify the presence of special nuclear material (SNM). Neutrons emitted from SNM are used to tag muon-induced fission events in actinides and laminography is used to form images of the stopping material. This technique allows the imaging of SNM-bearing objects tagged using muon tracking detectors located above or to the side of the objects, and may have potential applications in warhead verification scenarios. During the experiment described here we did not attempt to distinguish the type or grade of the SNM.
NASA Astrophysics Data System (ADS)
Takahashi, Y.; Misawa, T.; Yagi, T.; Pyeon, C. H.; Kimura, M.; Masuda, K.; Ohgaki, H.
2015-10-01
The detection of special nuclear materials (SNM) is an important issue for nuclear security. The interrogation systems used in a sea port and an airport are developed in the world. The active neutron-based interrogation system is the one of the candidates. We are developing the active neutron-based interrogation system with a D-D fusion neutron source for the nuclear security application. The D-D neutron source is a compact discharge-type fusion neutron source called IEC (Inertial-Electrostatic Confinement fusion) device which provides 2.45 MeV neutrons. The nuclear materials emit the highenergy neutrons by fission reaction. High-energy neutrons with energies over 2.45 MeV amount to 30% of all the fission neutrons. By using the D-D neutron source, the detection of SNMs is considered to be possible with the attention of fast neutrons if there is over 2.45 MeV. Ideally, neutrons at En>2.45 MeV do not exist if there is no nuclear materials. The detection of fission neutrons over 2.45 MeV are hopeful prospect for the detection of SNM with a high S/N ratio. In the future, the experiments combined with nuclear materials and a D-D neutron source will be conducted. Furthermore, the interrogation system will be numerically investigated by using nuclear materials, a D-D neutron source, and a steel container.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cester, D.; Lunardon, M.; Stevanato, L.
2015-07-01
MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)
Integrated Performance Testing Workshop, Modules 6 - 11
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leach, Janice; Torres, Teresa M.
These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements
NASA Astrophysics Data System (ADS)
Johnson, J. Bruce; Reeve, S. W.; Burns, W. A.; Allen, Susan D.
2010-04-01
Termed Special Nuclear Material (SNM) by the Atomic Energy Act of 1954, fissile materials, such as 235U and 239Pu, are the primary components used to construct modern nuclear weapons. Detecting the clandestine presence of SNM represents an important capability for Homeland Security. An ideal SNM sensor must be able to detect fissile materials present at ppb levels, be able to distinguish between the source of the detected fissile material, i.e., 235U, 239Pu, 233U or other fission source, and be able to perform the discrimination in near real time. A sensor with such capabilities would provide not only rapid identification of a threat but, ultimately, information on the potential source of the threat. For example, current detection schemes for monitoring clandestine nuclear testing and nuclear fuel reprocessing to provide weapons grade fissile material rely largely on passive air sampling combined with a subsequent instrumental analysis or some type of wet chemical analysis of the collected material. It would be highly useful to have a noncontact method of measuring isotopes capable of providing forensic information rapidly at ppb levels of detection. Here we compare the use of Kr, Xe and I as "canary" species for distinguishing between 235U and 239Pu fission sources by spectroscopic methods.
NASA Astrophysics Data System (ADS)
Alfonso, Krystal; Elsalim, Mashal; King, Michael; Strellis, Dan; Gozani, Tsahi
2013-04-01
MCNPX simulations have been used to guide the development of a portable inspection system for narcotics, explosives, and special nuclear material (SNM) detection. The system seeks to address these threats to national security by utilizing a high-yield, compact neutron source to actively interrogate the threats and produce characteristic signatures that can then be detected by radiation detectors. The portability of the system enables rapid deployment and proximity to threats concealed in small spaces. Both dD and dT electronic neutron generators (ENG) were used to interrogate ammonium nitrate fuel oil (ANFO) and cocaine hydrochloride, and the detector response of NaI, CsI, and LaBr3 were compared. The effect of tungsten shielding on the neutron flux in the gamma ray detectors was investigated, while carbon, beryllium, and polyethylene ENG moderator materials were optimized by determining the reaction rate density in the threats. In order to benchmark the modeling results, experimental measurements are compared with MCNPX simulations. In addition, the efficiency and die-away time of a portable differential die-away analysis (DDAA) detector using 3He proportional counters for SNM detection has been determined.
Explosives (and other threats) detection using pulsed neutron interrogation and optimized detectors
NASA Astrophysics Data System (ADS)
Strellis, Dan A.; Elsalim, Mashal; Gozani, Tsahi
2011-06-01
We have previously reported results from a human-portable system using neutron interrogation to detect contraband and explosives. We summarized our methodology for distinguishing threat materials such as narcotics, C4, and mustard gas in the myriad of backgrounds present in the maritime environment. We are expanding our mission for the Domestic Nuclear Detection Office (DNDO) to detect Special Nuclear Material (SNM) through the detection of multiple fission signatures without compromising the conventional threat detection performance. This paper covers our initial investigations into using neutrons from compact pulsed neutron generators via the d(D,n)3He or d(T,n)α reactions with energies of ~2.5 and 14 MeV, respectively, for explosives (and other threats) detection along with a variety of gamma-ray detectors. Fast neutrons and thermal neutrons (after successive collisions) can stimulate the emission of various threat detection signatures. For explosives detection, element-specific gamma-ray signatures via the (n,n'γ) inelastic scattering reaction and the (n,'γ) thermal capture reaction are detected. For SNM, delayed gamma-rays following fission can be measured with the same detector. Our initial trade-off investigations of several gamma-ray detectors types (NaI, CsI, LaBr3, HPGe) for measuring gamma-ray signatures in a pulsed neutron environment for potential application in a human-portable active interrogation system are covered in this paper.
NASA Astrophysics Data System (ADS)
Streicher, Michael W.
A nuclear weapon detonation remains one of the gravest threats to the global community. Although the likelihood of a nuclear event remains small, the economic and political ramifications of an event are vast. The surest way to reduce the probability of an incident is to account for the special nuclear materials (SNM) which can be used to produce a nuclear weapon. Materials which can be used to manufacture a radiological dispersion device ("dirty bomb") must also be monitored. Rapidly-deployable, commercially-available, room-temperature imaging gamma-ray spectrometers are improving the ability of authorities to intelligently and quickly respond to threats. New electronics which digitally-sample the radiation-induced signals in CdZnTe detectors have expanded the capabilities of these sensors. This thesis explores national security applications where digital readout of CdZnTe detectors significantly enhances capabilities. Radioactive sources can be detected more quickly using digitally-sampled CdZnTe detector due to the improved energy resolution. The excellent energy resolution also improves the accuracy of measurements of uranium enrichment and allows users to measure plutonium grade. Small differences in the recorded gamma-ray energy spectrum can be used to estimate the effective atomic number and mass thickness of materials shielding SNM sources. Improved position resolution of gamma-ray interactions through digital readout allows high resolution gamma-ray images of SNM revealing information about the source configuration. CdZnTe sensors can detect the presence of neutrons, indirectly, through measurement of gamma rays released during capture of thermal neutrons by Cd-113 or inelastic scattering with any constituent nuclei. Fast neutrons, such as those released following fission, can be directly detected through elastic scattering interactions in the detector. Neutrons are a strong indicator of fissile material, and the background neutron rate is much lower than the gamma-ray background rate. Neutrons can more easily penetrate shielding materials as well which can greatly aid in the detection of shielded SNM. Digital CdZnTe readout enables the sensors to maintain excellent energy resolution at high count rates. Pulse pile-up and preamplifier decay can be monitored and corrected for on an event-by-event basis limiting energy resolution degradation in dose rates higher than 100 mR/hr. Finally, new iterations of the digital electronics have enhanced gamma-ray detection capabilities at high photon energies. Currently, gamma rays with energy up to 4.4 MeV have been detected. High-energy photon detection is critical for many proposed active interrogation systems.
New perspectives for undoped CaF2 scintillator as a threshold activation neutron detector
NASA Astrophysics Data System (ADS)
Sibczynski, Pawel; Dziedzic, Andrzej; Grodzicki, Krystian; Iwanowska-Hanke, Joanna; Moszyński, Marek; Swiderski, Lukasz; Syntfeld-Każuch, Agnieszka; Wolski, Dariusz; Carrel, Frédérick; Grabowski, Amélie; Hamel, Matthieu; Laine, Frederic; Sari, Adrien; Iovene, Alessandro; Tintori, Carlo; Fontana, Cristiano; Pino, Felix
2018-01-01
In this paper we present the prompt photofission neutron detection performance of undoped CaF2 scintillator using Threshold Activation Detection (TAD). The study is carried out in the frame of C-BORD Horizon 2020 project, during which an efficient toolbox for high volume freight non-intrusive inspection (NII) is under development. Technologies for radiation monitoring are the part of the project. Particularly, detection of various radiological threats on country borders plays an important significant role in Homeland Security applications. Detection of illegal transfer of Special Nuclear Material (SNM) - 235U, 233U and 239Pu - is particular due to the potential use for production of nuclear weapon as well as radiological dispersal device (RDD) V known also as a "dirty bomb". This technique relies on activation of 19F nuclei in the scintillator medium by fast neutrons and registration of high-energy β particles and γ-rays from the decay of reaction products. The radiation from SNM is detected after irradiation in order to avoid detector blinding. Despite the low 19F(n,α)16N or 19F(n,p)19O reaction cross-section, the method could be a good solution for detection of shielded nuclear material. Results obtained with the CaF2 detector were compared with the previous study done for BaF2 and 3He detector. These experimental results were obtained using 252Cf source and 9 MeV Varian Linatron M9 linear accelerator (LINAC). Finally, performance of the prompt neutron detection system based on CaF2 will be validated at Rotterdam Seaport during field trails in 2018.
Calibrating and training of neutron based NSA techniques with less SNM standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geist, William H; Swinhoe, Martyn T; Bracken, David S
2010-01-01
Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Montemore » Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicholson, Andrew D.; Croft, Stephen; McElroy, Robert Dennis
2017-08-01
The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but itmore » is recognized that greater rigor is needed and achievable using modern statistical methods.« less
NASA Astrophysics Data System (ADS)
Grimes, T. F.; Hagen, A. R.; Archambault, B. C.; Taleyarkhan, R. P.
2018-03-01
This paper describes the development of a SNM detection system for interrogating 1m3 cargos via the combination of a D-D neutron interrogation source (with and without reflectors) and tensioned metastable fluid detectors (TMFDs). TMFDs have been previously shown (Taleyarkhan et al., 2008; Grimes et al., 2015; Grimes and Taleyarkhan, 2016; Archambault et al., 2017; Hagen et al., 2016) to be capable of using Threshold Energy Neutron Analysis (TENA) techniques to reject the ∼2.45 MeV D-D interrogating neutrons while still remaining sensitive to >2.45 MeV neutrons resulting from fission in the target (HEU) material. In order to enhance the performance, a paraffin reflector was included around the accelerator head. This reflector was used to direct neutrons into the package to increase the fission signal, lower the energy of the interrogating neutrons to increase the fission cross-section with HEU, and, also to direct interrogating neutrons away from the detectors in order to enhance the required discrimination between interrogating and fission neutrons. Experiments performed with a 239 Pu-Be neutron source and MnO2 indicated that impressive performance gains could be made by placing a parabolic paraffin moderator between the interrogation source and an air-filled cargo container with HEU placed at the center. However, experiments with other cargo fillers (as specified in the well-known ANSI N42.41-2007 report), and with HEU placed in locations other than the center of the package indicated that other reflector geometries might be superior due to over-"focusing" and the increased solid angle effects due to the accommodation of the moderator geometry. The best performance for the worst case of source location and box fill was obtained by placing the reflector only behind the D-D neutron source rather than in front of it. Finally, it was shown that there could be significant gains in the ability to detect concealed SNM by operating the system in multiple geometric configurations. Worst case scenarios were created by filling the box with hydrogenous material and placing the HEU as far away as possible from the neutron source. The performance of the system in the worst-case scenarios were greatly improved by exchanging the location of the accelerator and the opposite TMFD panel half way through interrogation. Using this operation, scenarios with positions of the concealed SNM that were once the most challenging to successfully detect became readily detectable.
A multisite randomized trial of social norms marketing campaigns to reduce college student drinking.
DeJong, William; Schneider, Shari Kessel; Towvim, Laura Gomberg; Murphy, Melissa J; Doerr, Emily E; Simonsen, Neal R; Mason, Karen E; Scribner, Richard A
2006-11-01
An 18-site randomized trial was conducted to determine the effectiveness of social norms marketing (SNM) campaigns in reducing college student drinking. The SNM campaigns are intended to correct misperceptions of subjective drinking norms and thereby drive down alcohol consumption. Institutions of higher education were randomly assigned to treatment and control groups. At the treatment group institutions, SNM campaigns delivered school-specific, data-driven messages through a mix of campus media venues. Cross-sectional student surveys were conducted by mail at baseline (n = 2,771) and at posttest 3 years later (n = 2,939). Hierarchical linear modeling was applied to examine multiple drinking outcomes, taking intraclass correlation into account. Controlling for other predictors, having an SNM campaign was significantly associated with lower perceptions of student drinking levels and lower alcohol consumption, as measured by a composite drinking scale, recent maximum consumption, blood alcohol concentration for recent maximum consumption, drinks consumed when partying, and drinks consumed per week. A moderate mediating effect of normative perceptions on student drinking was demonstrated by an attenuation of the Experimental Group x Time interaction, ranging from 16.4% to 39.5% across measures. Additional models that took into account the intensity of SNM campaign activity at the treatment institutions suggested that there was a dose-response relationship. This study is the most rigorous evaluation of SNM campaigns conducted to date. Analysis revealed that students attending institutions that implemented an SNM campaign had a lower relative risk of alcohol consumption than students attending control group institutions.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... Class C (GTCC) process waste at the Humboldt Bay ISFSI. PG&E submitted its license amendment request by... proposed amendment to License No. SNM-2514 to allow storage of GTCC process waste at the Humboldt Bay ISFSI... fuel and is authorized by NRC, under License No. SNM-2514, to also store GTCC activated metal waste at...
Review of current neutron detection systems for emergency response
Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; ...
2014-09-05
Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution.more » Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10B), lithium-6 ( 6Li), and gadollinium-157 ( 157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.« less
Review of current neutron detection systems for emergency response
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; Kruschwitz, Craig
2014-09-01
Neutron detectors are used in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 (3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 (10B), lithium-6 (6Li), and gadollinium-157 (157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 (4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.
RNomics in Drosophila melanogaster: identification of 66 candidates for novel non-messenger RNAs
Yuan, Guozhong; Klämbt, Christian; Bachellerie, Jean-Pierre; Brosius, Jürgen; Hüttenhofer, Alexander
2003-01-01
By generating a specialised cDNA library from four different developmental stages of Drosophila melanogaster, we have identified 66 candidates for small non-messenger RNAs (snmRNAs) and have confirmed their expression by northern blot analysis. Thirteen of them were expressed at certain stages of D.melanogaster development, only. Thirty-five species belong to the class of small nucleolar RNAs (snoRNAs), divided into 15 members from the C/D subclass and 20 members from the H/ACA subclass, which mostly guide 2′-O-methylation and pseudouridylation, respectively, of rRNA and snRNAs. These also include two outstanding C/D snoRNAs, U3 and U14, both functioning as pre-rRNA chaperones. Surprisingly, the sequence of the Drosophila U14 snoRNA reflects a major change of function of this snoRNA in Diptera relative to yeast and vertebrates. Among the 22 snmRNAs lacking known sequence and structure motifs, five were located in intergenic regions, two in introns, five in untranslated regions of mRNAs, eight were derived from open reading frames, and two were transcribed opposite to an intron. Interestingly, detection of two RNA species from this group implies that certain snmRNA species are processed from alternatively spliced pre-mRNAs. Surprisingly, a few snmRNA sequences could not be found on the published D.melanogaster genome, which might suggest that more snmRNA genes (as well as mRNAs) are hidden in unsequenced regions of the genome. PMID:12736298
Development of a Time-tagged Neutron Source for SNM Detection
Ji, Qing; Ludewigt, Bernhard; Wallig, Joe; ...
2015-06-18
Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for themore » extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.« less
2016-05-31
UMKC-YIP-TR-2016 May 2016 Technical Report Prompt Neutron Spectrometry for Identification of SNM in Unknown Shielding...University of Missouri – Kansas City MSND: Micro-structured Neutron Detector HRM: Handheld Radiation Monitor PHS: Pulse Height Spectrum ANI: Active... Neutron Interrogation Distribution Statement A 6 Administrative Information and Acknowledgements Members of the University of Missouri
Akhter, Shamima; Lam, Yung C.; Chang, Sandy; Legerski, Randy J.
2013-01-01
Summary Conserved metallo β-Lactamase and β-CASP (CPSF-Artemis-Snm1-Pso2) domain nuclease family member SNM1B/Apollo is a shelterin-associated protein that localizes to telomeres through its interaction with TRF2. To study its in vivo role, we generated a knockout of SNM1B/Apollo in a mouse model. Snm1B/Apollo homozygous null mice die at birth with developmental delay and defects in multiple organ systems. Cell proliferation defects were observed in Snm1B/Apollo mutant mouse embryonic fibroblasts (MEFs) owing to high levels of telomeric end-to-end fusions. Deficiency of the nonhomologous end-joining (NHEJ) factor Ku70, but not p53, rescued the developmental defects and lethality observed in Snm1B/Apollo mutant mice as well as the impaired proliferation of Snm1B/Apollo-deficient MEFs. These findings demonstrate that SNM1B/Apollo is required to protect telomeres against NHEJ-mediated repair, which results in genomic instability and the consequent multi-organ developmental failure. Although Snm1B/Apollo-deficient MEFs exhibited high levels of apoptosis, abrogation of p53-dependent programmed cell death did not rescue the multi-organ developmental failure in the mice. PMID:20854421
Evidence for hSNM1B/Apollo functioning in the HSP70 mediated DNA damage response.
Anders, Marco; Mattow, Jens; Digweed, Martin; Demuth, Ilja
2009-06-01
The hSNM1B/Apollo protein is involved in the cellular response to DNA-damage as well as in the maintenance of telomeres during S-phase. TRF2 has been shown to interact physically with hSNM1B. As a core component of shelterin, TRF2 functions in organization and protection of telomeres. However, TRF2 was also shown to have a role in the early DNA-damage response, suggesting that hSNM1B and TRF2 cooperate in this dual function. Here we have used Tandem-Affinity-Purification in combination with mass spectrometry to identify additional binding partners of hSNM1B. This revealed HSC70, HSP72, HSP60 and beta-Tubulin to be hSNM1B-interactors. We have confirmed the interaction of hSNM1B and HSP70 in co-immunoprecipitation assays and found that hSNM1B binds to a C-terminal fragment of HSP72, known to contain the substrate binding domain. Depletion of HSP72 in human fibroblasts resulted in a significant reduction of nuclear hSNM1B foci. We also found the phosphorylation of CHK1 at serine 317 to be attenuated in response to UVC irradiation as a consequence of hSNM1B depletion, a result which extends our previous findings on the DNA-damage response function of hSNM1B. HSP70 chaperones have been implicated in the maintenance of genome stability and their expression is often aberrant in cancer. Our results presented here, suggest that the role in genome stability might not be specific to HSP70 but rather can be attributed, at least in part, to hSNM1B. This, together with its stimulating effect on ATM and ATR substrate phosphorylation in response to DNA-damage qualify hSNM1B as a putative target in cancer therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul, J. N.; Chin, M. R.; Sjoden, G. E.
2013-07-01
A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reactionmore » rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)« less
Akhter, Shamima; Lam, Yung C; Chang, Sandy; Legerski, Randy J
2010-12-01
Conserved metallo β-Lactamase and β-CASP (CPSF-Artemis-Snm1-Pso2) domain nuclease family member SNM1B/Apollo is a shelterin-associated protein that localizes to telomeres through its interaction with TRF2. To study its in vivo role, we generated a knockout of SNM1B/Apollo in a mouse model. Snm1B/Apollo homozygous null mice die at birth with developmental delay and defects in multiple organ systems. Cell proliferation defects were observed in Snm1B/Apollo mutant mouse embryonic fibroblasts (MEFs) owing to high levels of telomeric end-to-end fusions. Deficiency of the nonhomologous end-joining (NHEJ) factor Ku70, but not p53, rescued the developmental defects and lethality observed in Snm1B/Apollo mutant mice as well as the impaired proliferation of Snm1B/Apollo-deficient MEFs. These findings demonstrate that SNM1B/Apollo is required to protect telomeres against NHEJ-mediated repair, which results in genomic instability and the consequent multi-organ developmental failure. Although Snm1B/Apollo-deficient MEFs exhibited high levels of apoptosis, abrogation of p53-dependent programmed cell death did not rescue the multi-organ developmental failure in the mice. © 2010 The Authors. Aging Cell © 2010 Blackwell Publishing Ltd/Anatomical Society of Great Britain and Ireland.
SNM detection with an optimized water Cherenkov neutron detector
NASA Astrophysics Data System (ADS)
Dazeley, S.; Sweany, M.; Bernstein, A.
2012-11-01
Special Nuclear Material (SNM) can either spontaneously fission or be induced to do so: either case results in neutron emission. For this reason, neutron detection performs a crucial role in the functionality of Radiation Portal Monitoring (RPM) devices. Since neutrons are highly penetrating and difficult to shield, they could potentially be detected escaping even a well-shielded cargo container. If the shielding were sophisticated, detecting escaping neutrons would require a highly efficient detector with close to full solid angle coverage. In 2008, we reported the successful detection of neutrons with a 250 liter (l) gadolinium doped water Cherenkov prototype [1]—a technology that could potentially be employed cost effectively with full solid angle coverage. More recently we have built and tested both 1-kl and 3.5-kl versions [2], demonstrating that very large, cost effective, non-flammable and environmentally benign neutron detectors can be operated efficiently without being overwhelmed by background. In this paper, we present a new design for a modular system of water-based neutron detectors that could be deployed as a real RPM. The modules contain a number of optimizations that have not previously been combined within a single system. We present simulations of the new system, based on the performance of our previous detectors. Our simulations indicate that an optimized system such as is presented here could achieve SNM sensitivity competitive with a large 3He-based system. Moreover, the realization of large, cost effective neutron detectors could, for the first time, enable the detection of multiple neutrons per fission from within a large object such as a cargo container. Such a signal would provide a robust indication of the presence of fissioning material, reducing the frequency of false alarms while increasing sensitivity.
SNM Detection with an Optimized Water Cherenkov Neutron Detector
Dazeley, S.; Sweany, M.; Bernstein, A.
2012-07-23
Special Nuclear Material (SNM) can either spontaneously fission or be induced to do so: either case results in neutron emission. For this reason, neutron detection performs a crucial role in the functionality of Radiation Portal Monitoring (RPM) devices. Since neutrons are highly penetrating and difficult to shield, they could potentially be detected escaping even a well-shielded cargo container. If the shielding were sophisticated, detecting escaping neutrons would require a highly efficient detector with close to full solid angle coverage. In 2008, we reported the successful detection of neutrons with a 250 liter (l) gadolinium doped water Cherenkov prototype—a technology thatmore » could potentially be employed cost effectively with full solid angle coverage. More recently we have built and tested both 1-kl and 3.5-kl versions, demonstrating that very large, cost effective, non-flammable and environmentally benign neutron detectors can be operated efficiently without being overwhelmed by background. In our paper, we present a new design for a modular system of water-based neutron detectors that could be deployed as a real RPM. The modules contain a number of optimizations that have not previously been combined within a single system. We present simulations of the new system, based on the performance of our previous detectors. These simulations indicate that an optimized system such as is presented here could achieve SNM sensitivity competitive with a large 3He-based system. Moreover, the realization of large, cost effective neutron detectors could, for the first time, enable the detection of multiple neutrons per fission from within a large object such as a cargo container. Such a signal would provide a robust indication of the presence of fissioning material, reducing the frequency of false alarms while increasing sensitivity.« less
A Neutron Based Interrogation System For SNM In Cargo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, Steven Z.; Koltick, David S.
A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo. The RAPID technique allows for the interrogation of containers at neutron production rates between {approx}1x10{sup 8} neutrons/s and {approx}3x10{sup 8} neutrons/s. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10{sup -4} false positive rate permore » interrogated voxel of cargo. Detection times of 5 minutes were found for a maximally loaded cargo container uniformly filled with iron and as low as 1 second in containers loaded to 1/4 of full capacity with either iron or wood. The worse case system performance, 30 minutes interrogation time, occurs for a maximally loaded container containing wood at 0.4 g/cm{sup 3}.« less
Demuth, Ilja; Digweed, Martin; Concannon, Patrick
2004-11-11
DNA interstrand crosslinks (ICLs) are critical lesions for the mammalian cell since they affect both DNA strands and block transcription and replication. The repair of ICLs in the mammalian cell involves components of different repair pathways such as nucleotide-excision repair and the double-strand break/homologous recombination repair pathways. However, the mechanistic details of mammalian ICL repair have not been fully delineated. We describe here the complete coding sequence and the genomic organization of hSNM1B, one of at least three human homologs of the Saccharomyces cerevisiae PSO2 gene. Depletion of hSNM1B by RNA interference rendered cells hypersensitive to ICL-inducing agents. This requirement for hSNM1B in the cellular response to ICL has been hypothesized before but never experimentally verified. In addition, siRNA knockdown of hSNM1B rendered cells sensitive to ionizing radiation, suggesting the possibility of hSNM1B involvement in homologous recombination repair of double-strand breaks arising as intermediates of ICL repair. Monoubiquitination of FANCD2, a key step in the FANC/BRCA pathway, is not affected in hSNM1B-depleted HeLa cells, indicating that hSNM1B is probably not a part of the Fanconi anemia core complex. Nonetheless, similarities in the phenotype of hSNM1B-depleted cells and cultured cells from patients suffering from Fanconi anemia make hSNM1B a candidate for one of the as yet unidentified Fanconi anemia genes not involved in monoubiquitination of FANCD2.
Sacral neuromodulations for female lower urinary tract, pelvic floor, and bowel disorders.
Wehbe, Salim A; Whitmore, Kristene; Ho, Mat H
2010-10-01
In recent years, sacral neuromodulation (SNM) has been investigated for the treatment of various types of lower urinary tract and bowel dysfunctions. This review discusses recently published data related to the therapeutic applications of SNM in female lower urinary tract, pelvic floor, and bowel disorders. SNM has been employed initially in the treatment of refractory idiopathic overactive bladder, urge urinary incontinence, and chronic nonobstructive urinary retention. Since then, several studies, including randomized and controlled trials, have confirmed the therapeutic effects of SNM in these disorders. The applications of SNM are now extended to the treatment of other female pelvic problems, such as fecal incontinence, chronic constipation, interstitial cystitis/painful bladder syndrome, sexual dysfunction, and neurogenic disorders, with similar promising results. SNM is approved by the Food and Drug Administration for the treatment of idiopathic overactive bladder, urge urinary incontinence, and chronic nonobstructive urinary retention. SNM is not yet an approved method for the treatment of other pelvic disorders, but data supporting its benefit are emerging. The major advantage of SNM lies in its potential to treat the bladder, urethral sphincter, anal sphincters, and pelvic floor muscles simultaneously, which might result in better therapeutic effects.
Active detection of shielded SNM with 60-keV neutrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagmann, C; Dietrich, D; Hall, J
2008-07-08
Fissile materials, e.g. {sup 235}U and {sup 239}Pu, can be detected non-invasively by active neutron interrogation. A unique characteristic of fissile material exposed to neutrons is the prompt emission of high-energy (fast) fission neutrons. One promising mode of operation subjects the object to a beam of medium-energy (epithermal) neutrons, generated by a proton beam impinging on a Li target. The emergence of fast secondary neutrons then clearly indicates the presence of fissile material. Our interrogation system comprises a low-dose 60-keV neutron generator (5 x 10{sup 6}/s), and a 1 m{sup 2} array of scintillators for fast neutron detection. Preliminary experimentalmore » results demonstrate the detectability of small quantities (370 g) of HEU shielded by steel (200 g/cm{sup 2}) or plywood (30 g/cm{sup 2}), with a typical measurement time of 1 min.« less
Homeland Security and Contraband Detection
NASA Astrophysics Data System (ADS)
Lanza, R. C.
Detection of contraband and illicit materials has become increasingly important, especially since the terrorist attacks in the United States on September 11, 2001. The nature of the detection problem embodies both physics issues and a set of operational constraints that limit the practical application of neutrons. The issue under consideration is detection of materials that are considered serious threats; these may include explosives; radioactive materials, fissile materials, and other materials associated with nuclear weapons, often referred to as special nuclear material (SNM). The overriding constraint is in the physics: systems must be based on clean physics; but unlike physics experiments, detection systems work under the limitation that materials must be identified nonintrusively, without interrupting the normal flow of commerce and with a high probability of detection and a low probability of false alarms. A great deal of work has been reported in the literature on neutron-based techniques for detecting explosives and drugs. The largest impetus by far for detecting explosives comes from aviation industry requirements for inspecting luggage and, to a lesser extent, cargo. The major alternative techniques are either X-ray-based or chemical trace detection methods that look for small traces of explosive residues. The limitations of the X-ray and trace methods in detecting explosives are well known, but currently (2008) it is safe to say that no neutron- or nuclear-based technique is being used routinely for security inspection, despite extensive development of these methods. Smuggling of nuclear materials has become a concern, and neutron techniques are particularly attractive for detecting them. Given the limitations of X-ray techniques and the need for SNM detection, it is now useful to reexamine neutron methodologies, particularly imaging. A significant number of neutron-based techniques have been proposed and are under development for security applications, especially SNM detection, but describing how they work is beyond the scope of the chapter. Instead, one particular approach to neutron imaging, neutron resonance radiography (NRR), is discussed in detail as it illustrates many of the issues connected with imaging and detection.
32 CFR 223.7 - Procedures-determination of DoD UCNI.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Detection and Security Alarm Systems. (i) Information on the layout or design of security and alarm systems...) Frequency and schedule of DoD SNM inventories. (3) Facility Description. (i) Maps, conceptual design, and...
32 CFR 223.7 - Procedures-determination of DoD UCNI.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Detection and Security Alarm Systems. (i) Information on the layout or design of security and alarm systems...) Frequency and schedule of DoD SNM inventories. (3) Facility Description. (i) Maps, conceptual design, and...
SNM1B/Apollo in the DNA damage response and telomere maintenance
Schmiester, Maren; Demuth, Ilja
2017-01-01
hSNM1B/Apollo is a member of the highly conserved β-CASP subgroup within the MBL superfamily of proteins. It interacts with several DNA repair proteins and functions within the Fanconi anemia pathway in response to DNA interstrand crosslinks. As a shelterin accessory protein, hSNM1B/Apollo is also vital for the generation and maintenance of telomeric overhangs. In this review, we will summarize studies on hSNM1B/Apollo's function, including its contribution to DNA damage signaling, replication fork maintenance, control of topological stress and telomere protection. Furthermore, we will highlight recent studies illustrating hSNM1B/Apollo's putative role in human disease. PMID:28430596
SNM1B/Apollo in the DNA damage response and telomere maintenance.
Schmiester, Maren; Demuth, Ilja
2017-07-18
hSNM1B/Apollo is a member of the highly conserved β-CASP subgroup within the MBL superfamily of proteins. It interacts with several DNA repair proteins and functions within the Fanconi anemia pathway in response to DNA interstrand crosslinks. As a shelterin accessory protein, hSNM1B/Apollo is also vital for the generation and maintenance of telomeric overhangs. In this review, we will summarize studies on hSNM1B/Apollo's function, including its contribution to DNA damage signaling, replication fork maintenance, control of topological stress and telomere protection. Furthermore, we will highlight recent studies illustrating hSNM1B/Apollo's putative role in human disease.
Henzlova, Daniela; Menlove, Howard Olsen; Croft, Stephen; ...
2015-06-15
In the field of nuclear safeguards, passive neutron multiplicity counting (PNMC) is a method typically employed in non-destructive assay (NDA) of special nuclear material (SNM) for nonproliferation, verification and accountability purposes. PNMC is generally performed using a well-type thermal neutron counter and relies on the detection of correlated pairs or higher order multiplets of neutrons emitted by an assayed item. To assay SNM, a set of parameters for a given well-counter is required to link the measured multiplicity rates to the assayed item properties. Detection efficiency, die-away time, gate utilization factors (tightly connected to die-away time) as well as optimummore » gate width setting are among the key parameters. These parameters along with the underlying model assumptions directly affect the accuracy of the SNM assay. In this paper we examine the role of gate utilization factors and the single exponential die-away time assumption and their impact on the measurements for a range of plutonium materials. In addition, we examine the importance of item-optimized coincidence gate width setting as opposed to using a universal gate width value. Finally, the traditional PNMC based on multiplicity shift register electronics is extended to Feynman-type analysis and application of this approach to Pu mass assay is demonstrated.« less
Detection Of Special Nuclear Materials Tagged Neutrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deyglun, Clement; Perot, Bertrand; Carasco, Cedric
In order to detect Special Nuclear Materials (SNM) in unattended luggage or cargo containers in the field of homeland security, fissions are induced by 14 MeV neutrons produced by an associated particle DT neutron generator, and prompt fission particles correlated with tagged neutron are detected by plastic scintillators. SMN produce high multiplicity events due to induced fissions, whereas nonnuclear materials produce low multiplicity events due to cross-talk, (n,2n) or (n,n'γ) reactions. The data acquisition electronics is made of compact FPGA boards. The coincidence window is triggered by the alpha particle detection, allowing to tag the emission date and direction ofmore » the 14 MeV interrogating neutron. The first part of the paper presents experiment vs. calculation comparisons to validate MCNP-PoliMi simulations and the post-processing tools developed with the data analysis framework ROOT. Measurements have been performed using different targets (iron, lead, graphite), first with small plastic scintillators (10 x 10 x 10 cm{sup 3}) and then with large detectors (10 x 10 x 100 cm{sup 3}) to demonstrate that nuclear materials can be differentiated from nonnuclear dense materials (iron, lead) in iron and wood matrixes. A special attention is paid on SNM detection in abandoned luggage. In the second part of the paper, the performances of a cargo container inspection system are studied by numerical simulation, following previous work reported in. Detectors dimensions and shielding against the neutron generator background are optimized for container inspection. Events not correlated to an alpha particle (uncorrelated background), counting statistics, time and energy resolutions of the data acquisition system are all taken into account in a realistic numerical model. The impact of the container matrix (iron, ceramic, wood) has been investigated by studying the system capability to detect a few kilograms of SNM in different positions in the cargo container, within 10 min acquisitions. (authors)« less
NASA Astrophysics Data System (ADS)
Lee, Sangkyu
Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection methodologies are fused into two algorithms with mathematical functions providing: reliable identification of radioisotopes in gamma spectroscopy; noise reduction and precision enhancement in muon tomography; and the atomic number and density estimation in gamma radiography. It is expected that these new algorithms maybe implemented at portal scanning systems with the goal to enhance the accuracy and reliability in detecting nuclear materials inside the cargo containers.
Special nuclear material simulation device
Leckey, John H.; DeMint, Amy; Gooch, Jack; Hawk, Todd; Pickett, Chris A.; Blessinger, Chris; York, Robbie L.
2014-08-12
An apparatus for simulating special nuclear material is provided. The apparatus typically contains a small quantity of special nuclear material (SNM) in a configuration that simulates a much larger quantity of SNM. Generally the apparatus includes a spherical shell that is formed from an alloy containing a small quantity of highly enriched uranium. Also typically provided is a core of depleted uranium. A spacer, typically aluminum, may be used to separate the depleted uranium from the shell of uranium alloy. A cladding, typically made of titanium, is provided to seal the source. Methods are provided to simulate SNM for testing radiation monitoring portals. Typically the methods use at least one primary SNM spectral line and exclude at least one secondary SNM spectral line.
Sacral neuromodulation for lower urinary tract dysfunction.
Van Kerrebroeck, Philip E V; Marcelissen, Tom A T
2012-08-01
To review the technique, indications, results and working mechanisms of sacral neuromodulation (SNM) for lower urinary tract dysfunction. The available literature on SNM for lower urinary tract dysfunction was searched. Based on the information available in the literature and also based on personal experience, the urological indications, technique, mechanisms of action and results of SNM are presented and discussed. SNM for lower urinary tract dysfunction involves stimulation of the 3rd sacral nerve with an electrode implanted in the sacral foramen and connected to a pulse generator. The technique is accepted by the FDA since 1997. Currently, SNM for lower urinary tract dysfunction has been successfully used in about 26,000 patients with various forms of lower urinary tract dysfunction, including urgency, frequency and urgency incontinence as well as non-obstructive urinary retention. The actual procedure of SNM consists of a minimal invasive technique and is effective in about 70% of the patients who have been implanted with a permanent system. Also, in pelvic pain, interesting results have been described. SNM modulates the micturition reflexes at different levels in the central nervous system. Sacral neuromodulation is a safe and effective therapy for various forms of lower urinary tract dysfunction, including urgency, frequency and urgency incontinence as well as non-obstructive urinary retention. It should be the first choice after failure of maximal conservative therapy.
Economic evaluation of sacral neuromodulation in overactive bladder: A Canadian perspective.
Hassouna, Magdy M; Sadri, Hamid
2015-01-01
Refractory overactive bladder (OAB) with urge incontinence is an underdiagnosed condition with substantial burden on the healthcare system and diminished patient's quality-of-life. Many patients will fail conservative treatment with optimized medical-therapy (OMT) and may benefit from minimally invasive procedures, including sacral-neuromodulation (SNM) or botulinum-toxin (BonT-A). The goal of this study was to estimate the cost-efectiveness of SNM vs. OMT and BonT-A as important parameters from coverage and access to a therapy. A Markov model with Monte-Carlo simulation was used to assess the incremental cost effectiveness ratio (ICER) of SNM vs. BonT-A and OMT both in deterministic and probabilistic analysis from a provincial payer perspective over a 10-year time horizon with 9-month Markov-cycles. Clinical data, healthcare resource utilization, and utility scores were acquired from recent publications and an expert panel of 7 surgeons. Cost data (2014-Dollars) were derived from provincial health insurance policy, drug benefit formulary, and hospital data. All cost and outcomes were discounted at a 3% rate. The annual (year 1-10) incremental quality-adjusted life years for SNM vs. BonT-A was 0.05 to 0.51 and SNM vs. OMT was 0.19 to 1.76. The annual incremental cost of SNM vs. BonT-A was $7237 in year 1 and -$9402 in year 10 and was between $8878 and -$11 447 vs. OMT. In the base-case deterministic analysis, the ICER for SNM vs. BonT-A and OMT were within the acceptable range ($44 837 and $15 130, respectively) at the second year of therapy, and SNM was dominant in consequent years. In the base-case analysis the probability of ICER being below the acceptability curve (willingness-to-pay $50 000) was >99% for SNM vs. BonT-A at year 3 and >95% for OMT at year 2. SNM is a cost-effective treatment option to manage patients with refractory OAB when compared to either BonT-A or OMT. From a Canadian payers' perspective, SNM may be considered a first-line treatment option in management of patients with OAB with superior long-term outcomes. Similar to all economic analysis, this study has limitations which are based on the assumptions of the used model.
Benefits of Time Correlation Measurements for Passive Screening
NASA Astrophysics Data System (ADS)
Murer, David; Blackie, Douglas; Peerani, Paolo
2014-02-01
The “FLASH Portals Project” is a collaboration between Arktis Radiation Detectors Ltd (CH), the Atomic Weapons Establishment (UK), and the Joint Research Centre (European Commission), supported by the Technical Support Working Group (TSWG). The program's goal was to develop and demonstrate a technology to detect shielded special nuclear materials (SNM) more efficiently and less ambiguously by exploiting time correlation. This study presents experimental results of a two-sided portal monitor equipped with in total 16 4He fast neutron detectors as well as four polyvinyltoluene (PVT) plastic scintillators. All detectors have been synchronized to nanosecond precision, thereby allowing the resolution of time correlations from timescales of tens of microseconds (such as (n, γ) reactions) down to prompt fission correlations directly. Our results demonstrate that such correlations can be detected in a typical radiation portal monitor (RPM) geometry and within operationally acceptable time scales, and that exploiting these signatures significantly improves the performance of the RPM compared to neutron counting. Furthermore, the results show that some time structure remains even in the presence of heavy shielding, thus significantly improving the sensitivity of the detection system to shielded SNM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bolotnikov,A.
2009-06-02
The project goals are: (1) Develop CMT radiation detectors - Demonstrate feasibility (Phase 1 is complete) and Improve material properties and device performance; (2) This project will lead to novel radiation detectors - high detection efficiency, high energy-resolution, ambient-temperature operation, and low production cost; and (3) Such detectors are needed in areas of nonproliferation and national security for detection of SNM. Research highlights are: (1) We achieved our Phase-I goal - Demonstration of CMT detector performance approaching that of CZT detectors; (2) Demonstrated that In-doped CMT is much closer to its anticipated performance as radiation detectors than other alternative materials,more » TlBr and HgI{sub 2} - Large crystal volumes, 10{sup 10}{Omega}{center_dot}cm, 3 x 10{sup -3}cm{sup 2}/V, and stable response; and (3) Conducted material and device characterization experiments - Detectors: I-V, {mu}{sub e}, ({mu}{tau}){sub e}, internal E fields, energy spectra, and high-resolution x-ray response mapping data and Materials - DLTS, TCT, PL, EPDs, XRD, PCD and IR transmission.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-02
... Materials License No. SNM-2504; Department of Energy; Fort St. Vrain Independent Spent Fuel Storage... INFORMATION CONTACT: Christopher Staab, Project Manager, Division of Spent Fuel Storage and Transportation... issued renewed Materials License No. SNM-2504 to the Department of Energy (DOE) for the receipt...
Simulations of Multi-Gamma Coincidences From Neutron-Induced Fission in Special Nuclear Materials
NASA Astrophysics Data System (ADS)
Kane, Steven; Gozani, Tsahi; King, Michael J.; Kwong, John; Brown, Craig; Gary, Charles; Firestone, Murray I.; Nikkel, James A.; McKinsey, Daniel N.
2013-04-01
A study is presented on the detection of illicit special nuclear materials (SNM) in cargo containers using a conceptual neutron-based inspection system with xenon-doped liquefied argon (LAr(Xe)) scintillation detectors for coincidence gamma-ray detection. For robustness, the system is envisioned to exploit all fission signatures, namely both prompt and delayed neutron and gamma emissions from fission reactions induced in SNM. However, this paper focuses exclusively on the analysis of the prompt gamma ray emissions. The inspection system probes a container using neutrons produced either by (d, D) or (d, T) in pulsed form or from an associated particle neutron generator to exploit the associated particle imaging (API) technique, thereby achieving background reduction and imaging. Simulated signal and background estimates were obtained in MCNPX (2.7) for a 2 kg sphere of enriched uranium positioned at the center of a 1m × 1m × 1m container, which is filled uniformly with wood or iron cargos at 0.1 g/cc or 0.4 g/cc. Detection time estimates are reported assuming probabilities of detection of 95% and false alarm of 0.5%.
Detection of Nuclear Weapons and Materials: Science, Technologies, Observations
2010-06-04
extensive use of photons, packets of energy with no rest mass and no electrical charge. Electromagnetic radiation consists of photons, and may be measured...bulk property, expressed as mass per unit volume. In general, the densest materials are those of high Z. These properties may be used to detect...SNM by detecting the time pattern of neutron generation. A subcritical mass of highly enriched uranium or weapons-grade plutonium can support a
[Sacral neuromodulation in urology - development and current status].
Schwalenberg, T; Stolzenburg, J-U; Kriegel, C; Gonsior, A
2012-01-01
Sacral neuromodulation (SNM) in urology is employed to treat refractory lower urinary tract dysfunction as well as chronic pelvic pain. Electrical stimulation of the sacral afferents (S2 - S4) causes activation and conditioning of higher autonomic and somatic neural structures and thereby influences the efferents controlling the urinary bladder, the rectum and their related sphincter systems. It is therefore possible to treat overactivity as well as hypocontractility and functional bladder neck obstruction. SNM treatment is conducted biphasically. Initially, test electrodes are placed to evaluate changes in micturition and pain parameters. If, in this first phase - called peripheral nerve evaluation (PNE test) - sufficient improvements are observed, the patient progresses to phase two which involves implantation of the permanent electrodes and impulse generator system. In recent years, the "two stage approach" with initial implantation of the permanent electrodes has been favoured as it increases treatment success rates. Long-term success rates of SNM vary significantly in the literature (50 - 80 %) due to heterogeneous patient populations as well as improved surgical approaches. With the introduction of "tined lead electrodes" (2002), tissue damage is reduced to a minimum. Technical innovation, financial feasibility (reimbursed in Germany since 2004) and wider application, especially in otherwise therapy-refractory patients or complex dysfunctions of the pelvis, have established SNM as a potent treatment option in urology. © Georg Thieme Verlag KG Stuttgart · New York.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-05
... disposal cells. SNM quantities, below what the NRC would consider to be a critical mass (i.e., 350 grams of... grams of SNM. This revision to the EnergySolutions license was approved after the NRC independently... grams of SNM. The selection of this alternative would allow WEC to meet the requirements of 10 CFR 20...
78 FR 46829 - Assistance to Foreign Atomic Energy Activities
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... Departments of Commerce and State Approved Activities 9. Medical Isotope Production 10. Activities Carried Out... production of special nuclear material (SNM). Proposed Sec. 810.2(c) would identify exempt activities, some... activities do not involve the production or use of special nuclear material; Production or extraction of...
Pregnancy in women with Fowler's syndrome treated with sacral neuromodulation.
Khunda, Azar; Karmarkar, Roopali; Abtahi, Bahareh; Gonzales, Gwen; Elneil, Sohier
2013-07-01
Our aim was to determine the impact of pregnancy on sacral neuromodulation (SNM) and vice versa in patients with Fowler's syndrome (FS), which is typified by chronic urinary retention (CUR). We performed a retrospective study of pregnancy in patients with FS who underwent a two-stage SNM implantation. Data were obtained using a standard questionnaire and clinical interview. There were a total of ten patients with 13 pregnancies. The SNM was switched off in ten of the 13 pregnancies, with CUR recurring in nine of the ten pregnancies and recurrent urinary tract infections (UTI) occurring in four of these pregnancies (more than three UTI in the pregnancy). Those in whom the device was left on continued to void normally. One woman had a first trimester miscarriage, eight pregnancies went to term, and four deliveries were premature. Caesarean section was performed in eight pregnancies for obstetric reasons. Four pregnancies resulted in a vaginal delivery. There were no congenital anomalies reported. Following delivery, four of nine women experienced dysfunction of their SNM device when it was switched back on. Turing off the SNM during pregnancy results in recurrence of CUR, with an increased risk of recurrent UTI associated with preterm delivery. This did not impact foetal well-being. The option of keeping the SNM on during pregnancy should therefore be considered, and as caesarean section affects the SNM device, we advise that caesarean section should only be performed for obstetric reasons.
Salewsky, Bastian; Schmiester, Maren; Schindler, Detlev; Digweed, Martin; Demuth, Ilja
2012-11-15
The recessive genetic disorder Fanconi anemia (FA) is clinically characterized by congenital defects, bone marrow failure and an increased incidence of cancer. Cells derived from FA patients exhibit hypersensitivity to DNA interstrand crosslink (ICL)-inducing agents. We have earlier reported a similar cellular phenotype for human cells depleted of hSNM1B/Apollo (siRNA). In fact, hSNM1B/Apollo has a dual role in the DNA damage response and in generation and maintenance of telomeres, the latter function involving interaction with the shelterin protein TRF2. Here we find that ectopically expressed hSNM1B/Apollo co-immunoprecipitates with SLX4, a protein recently identified as a new FA protein, FANCP, and known to interact with several structure-specific nucleases. As shown by immunofluorescence analysis, FANCP/SLX4 depletion (siRNA) resulted in a significant reduction of hSNM1B/Apollo nuclear foci, supporting the functional relevance of this new protein interaction. Interestingly, as an additional consequence of FANCP/SLX4 depletion, we found a reduction of cellular TRF2, in line with its telomere-related function. Finally, analysis of human cells following double knockdown of hSNM1B/Apollo and FANCP/SLX4 indicated that they function epistatically. These findings further substantiate the role of hSNM1B/Apollo in a downstream step of the FA pathway during the repair of DNA ICLs.
Snm1B/Apollo functions in the Fanconi anemia pathway in response to DNA interstrand crosslinks.
Mason, Jennifer M; Sekiguchi, JoAnn M
2011-07-01
Fanconi anemia (FA) is an inherited chromosomal instability disorder characterized by childhood aplastic anemia, developmental abnormalities and cancer predisposition. One of the hallmark phenotypes of FA is cellular hypersensitivity to agents that induce DNA interstrand crosslinks (ICLs), such as mitomycin C (MMC). FA is caused by mutation in at least 14 genes which function in the resolution of ICLs during replication. The FA proteins act within the context of a protein network in coordination with multiple repair factors that function in distinct pathways. SNM1B/Apollo is a member of metallo-β-lactamase/βCASP family of nucleases and has been demonstrated to function in ICL repair. However, the relationship between SNM1B and the FA protein network is not known. In the current study, we establish that SNM1B functions epistatically to the central FA factor, FANCD2, in cellular survival after ICL damage and homology-directed repair of DNA double-strand breaks. We also demonstrate that MMC-induced chromosomal anomalies are increased in SNM1B-depleted cells, and this phenotype is not further exacerbated upon depletion of either FANCD2 or another key FA protein, FANCI. Furthermore, we find that SNM1B is required for proper localization of critical repair factors, including FANCD2, BRCA1 and RAD51, to MMC-induced subnuclear foci. Our findings demonstrate that SNM1B functions within the FA pathway during the repair of ICL damage.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-17
... SNM in the form of fully-assembled fuel assemblies that would later form the initial reactor core of WBN2. The SNM in the fuel assemblies is enriched up to 5% in the isotope U-235. The fresh fuel... received the initial core for WBN2. The NRC has not yet issued the OL for the Unit 2 reactor. The...
NASA Astrophysics Data System (ADS)
Song, Shang; Faleo, Gaetano; Yeung, Raymond; Kant, Rishi; Posselt, Andrew M.; Desai, Tejal A.; Tang, Qizhi; Roy, Shuvo
2016-03-01
Problems associated with islet transplantation for Type 1 Diabetes (T1D) such as shortage of donor cells, use of immunosuppressive drugs remain as major challenges. Immune isolation using encapsulation may circumvent the use of immunosuppressants and prolong the longevity of transplanted islets. The encapsulating membrane must block the passage of host’s immune components while providing sufficient exchange of glucose, insulin and other small molecules. We report the development and characterization of a new generation of semipermeable ultrafiltration membrane, the silicon nanopore membrane (SNM), designed with approximately 7 nm-wide slit-pores to provide middle molecule selectivity by limiting passage of pro-inflammatory cytokines. Moreover, the use of convective transport with a pressure differential across the SNM overcomes the mass transfer limitations associated with diffusion through nanometer-scale pores. The SNM exhibited a hydraulic permeability of 130 ml/hr/m2/mmHg, which is more than 3 fold greater than existing polymer membranes. Analysis of sieving coefficients revealed 80% reduction in cytokines passage through SNM under convective transport. SNM protected encapsulated islets from infiltrating cytokines and retained islet viability over 6 hours and remained responsive to changes in glucose levels unlike non-encapsulated controls. Together, these data demonstrate the novel membrane exhibiting unprecedented hydraulic permeability and immune-protection for islet transplantation therapy.
Cohn, Joshua A; Kowalik, Casey G; Kaufman, Melissa R; Reynolds, W Stuart; Milam, Douglas F; Dmochowski, Roger R
2017-01-01
Sacral neuromodulation (SNM) remains one of the few effective treatments for refractory bladder and bowel dysfunction. However, SNM is associated with frequent need for surgical intervention, in many cases because of a failed battery. A rechargeable SNM system, with a manufacturer-reported battery life of 15 years or more, has entered post-market clinical testing in Europe but has not yet been approved for clinical testing in the United States. Areas covered: We review existing neuromodulation technologies for the treatment of lower urinary tract and bowel dysfunction and explore the limitations of available technology. In addition, we discuss implantation technique and device specifications and programming of the rechargeable SNM system in detail. Lastly, we present existing evidence for the use of SNM in bladder and bowel dysfunction and evaluate the anticipated trajectory of neuromodulation technologies over the next five years. Expert commentary: A rechargeable system for SNM is a welcome technological advance. However surgical revision not related to battery changes is not uncommon. Therefore, while a rechargeable system would be expected to reduce costs, it will not eliminate the ongoing maintenance associated with neuromodulation. No matter the apparent benefits, all new technologies require extensive post-market monitoring to ensure safety and efficacy.
Nutrient Limitation Governs Staphylococcus aureus Metabolism and Niche Adaptation in the Human Nose
Krismer, Bernhard; Liebeke, Manuel; Janek, Daniela; Nega, Mulugeta; Rautenberg, Maren; Hornig, Gabriele; Unger, Clemens; Weidenmaier, Christopher; Lalk, Michael; Peschel, Andreas
2014-01-01
Colonization of the human nose by Staphylococcus aureus in one-third of the population represents a major risk factor for invasive infections. The basis for adaptation of S. aureus to this specific habitat and reasons for the human predisposition to become colonized have remained largely unknown. Human nasal secretions were analyzed by metabolomics and found to contain potential nutrients in rather low amounts. No significant differences were found between S. aureus carriers and non-carriers, indicating that carriage is not associated with individual differences in nutrient supply. A synthetic nasal medium (SNM3) was composed based on the metabolomics data that permits consistent growth of S. aureus isolates. Key genes were expressed in SNM3 in a similar way as in the human nose, indicating that SNM3 represents a suitable surrogate environment for in vitro simulation studies. While the majority of S. aureus strains grew well in SNM3, most of the tested coagulase-negative staphylococci (CoNS) had major problems to multiply in SNM3 supporting the notion that CoNS are less well adapted to the nose and colonize preferentially the human skin. Global gene expression analysis revealed that, during growth in SNM3, S. aureus depends heavily on de novo synthesis of methionine. Accordingly, the methionine-biosynthesis enzyme cysteine-γ-synthase (MetI) was indispensable for growth in SNM3, and the MetI inhibitor DL-propargylglycine inhibited S. aureus growth in SNM3 but not in the presence of methionine. Of note, metI was strongly up-regulated by S. aureus in human noses, and metI mutants were strongly abrogated in their capacity to colonize the noses of cotton rats. These findings indicate that the methionine biosynthetic pathway may include promising antimicrobial targets that have previously remained unrecognized. Hence, exploring the environmental conditions facultative pathogens are exposed to during colonization can be useful for understanding niche adaptation and identifying targets for new antimicrobial strategies. PMID:24453967
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burr, Tom; Croft, Stephen; Jarman, Kenneth D.
The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings, and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically quantify total uncertainty in terms of “random” and “systematic” components, and then specify error bars for the total mass estimate in multiple items. Uncertainty quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed andmore » achievable using modern statistical methods. To this end, we describe the extent to which the guideline for expressing uncertainty in measurements (GUM) can be used for NDA. Also, we propose improvements over GUM for NDA by illustrating UQ challenges that it does not address, including calibration with errors in predictors, model error, and item-specific biases. A case study is presented using low-resolution NaI spectra and applying the enrichment meter principle to estimate the U-235 mass in an item. The case study illustrates how to update the current American Society for Testing and Materials guide for application of the enrichment meter principle using gamma spectra from a NaI detector.« less
Delayed Gamma-ray Spectroscopy for Safeguards Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mozin, Vladimir
The delayed gamma-ray assay technique utilizes an external neutron source (D-D, D-T, or electron accelerator-driven), and high-resolution gamma-ray spectrometers to perform characterization of SNM materials behind shielding and in complex configurations such as a nuclear fuel assembly. High-energy delayed gamma-rays (2.5 MeV and above) observed following the active interrogation, provide a signature for identification of specific fissionable isotopes in a mixed sample, and determine their relative content. Potential safeguards applications of this method are: 1) characterization of fresh and spent nuclear fuel assemblies in wet or dry storage; 2) analysis of uranium enrichment in shielded or non-characterized containers or inmore » the presence of a strong radioactive background and plutonium contamination; 3) characterization of bulk and waste and product streams at SNM processing plants. Extended applications can include warhead confirmation and warhead dismantlement confirmation in the arms control area, as well as SNM diagnostics for the emergency response needs. In FY16 and prior years, the project has demonstrated the delayed gamma-ray measurement technique as a robust SNM assay concept. A series of empirical and modeling studies were conducted to characterize its response sensitivity, develop analysis methodologies, and analyze applications. Extensive experimental tests involving weapons-grade Pu, HEU and depleted uranium samples were completed at the Idaho Accelerator Center and LLNL Dome facilities for various interrogation time regimes and effects of the neutron source parameters. A dedicated delayed gamma-ray response modeling technique was developed and its elements were benchmarked in representative experimental studies, including highresolution gamma-ray measurements of spent fuel at the CLAB facility in Sweden. The objective of the R&D effort in FY17 is to experimentally demonstrate the feasibility of the delayed gamma-ray interrogation of shielded SNM samples with portable neutron sources suitable for field applications.« less
New Non-Intrusive Inspection Technologies for Nuclear Security and Nonproliferation
NASA Astrophysics Data System (ADS)
Ledoux, Robert J.
2015-10-01
Comprehensive monitoring of the supply chain for nuclear materials has historically been hampered by non-intrusive inspection systems that have such large false alarm rates that they are impractical in the flow of commerce. Passport Systems, Inc. (Passport) has developed an active interrogation system which detects fissionable material, high Z material, and other contraband in land, sea and air cargo. Passport's design utilizes several detection modalities including high resolution imaging, passive radiation detection, effective-Z (EZ-3D™) anomaly detection, Prompt Neutrons from Photofission (PNPF), and Nuclear Resonance Fluorescence (NRF) isotopic identification. These technologies combine to: detect fissionable, high-Z, radioactive and contraband materials, differentiate fissionable materials from high-Z shielding materials, and isotopically identify actinides, Special Nuclear Materials (SNM), and other contraband (e.g. explosives, drugs, nerve agents). Passport's system generates a 3-D image of the scanned object which contains information such as effective-Z and density, as well as a 2-D image and isotopic and fissionable information for regions of interest.
Fast Neutron Detection using Pixelated CdZnTe Spectrometers
Streicher, Michael; Goodman, David; Zhu, Yuefeng; ...
2017-05-29
One important important signature of special nuclear materials (SNM) are fast neutrons. Fast neutrons have a low natural background rate and readily penetrate high atomic number materials which easily shield gamma-ray signatures. Thus, fast neutrons provide a complementary signal to gamma rays for detecting shielded SNM. Scattering kinematics dictate that a large nucleus (such as Cd or Te) will recoil with small kinetic energy after an elastic collision with a fast neutron. Charge carrier recombination and quenching further reduce the recorded energy deposited. Thus, the energy threshold of CdZnTe detectors must be very low in order to sense the smallmore » signals from these recoils. Here, the threshold was reduced to less than 5 keVee to demonstrate that the 5.9 keV x-ray line from 55Fe could be separated from electronic noise. Elastic scattering neutron interactions were observed as small energy depositions (less than 20 keVee) using digitally-sampled pulse waveforms from pixelated CdZnTe detectors. Characteristic gamma-ray lines from inelastic neutron scattering were also observed.« less
Neonatal Morbidity at Term, Early Child Development, and School Performance: A Population Study.
Bentley, Jason P; Schneuer, Francisco J; Lain, Samantha J; Martin, Andrew J; Gordon, Adrienne; Nassar, Natasha
2018-02-01
Investigate the association between severe neonatal morbidity (SNM) and child development and school performance among term infants. The study population included term infants without major congenital conditions born between 2000 and 2007 in New South Wales, Australia, with a linked record of developmental assessment at ages 4 to 6 years in 2009 or 2012 ( n = 144 535) or school performance at ages 7 to 9 years from 2009 to 2014 ( n = 253 447). Developmental outcomes included special needs or being vulnerable and/or at risk in 1 of 5 developmental domains. School performance outcomes were test exemption, or performing <-1 SD on reading or numeracy tests. Binary generalized estimating equations were used to estimate associations between SNM and outcomes, adjusting for sociodemographic, perinatal, and assessment and/or test characteristics. Overall, 2.1% of infants experienced SNM. The adjusted odds ratio (95% confidence interval) for SNM and physical health was 1.18 (1.08-1.29), 1.14 (1.02-1.26) for language and cognitive skills, and 1.14 (1.06-1.24) and 1.13 (1.05-1.21) for scoring <-1 SD in reading and numeracy, respectively. SNM was most strongly associated with special needs 1.34 (1.15-1.55) and test exemption 1.50 (1.25-1.81). SNM infants born at 37 to 38 weeks' gestation and who were small for gestational age had the greatest likelihood of poorer outcomes. Term infants with SNM have greater odds of poor neurodevelopment in childhood. These findings provide population-based information for families and can inform clinical counseling and guidelines for follow-up and early intervention. Copyright © 2018 by the American Academy of Pediatrics.
GNSS Spoofing Network Monitoring Based on Differential Pseudorange.
Zhang, Zhenjun; Zhan, Xingqun
2016-10-23
Spoofing is becoming a serious threat to various Global Navigation Satellite System (GNSS) applications, especially for those that require high reliability and security such as power grid synchronization and applications related to first responders and aviation safety. Most current works on anti-spoofing focus on spoofing detection from the individual receiver side, which identifies spoofing when it is under an attack. This paper proposes a novel spoofing network monitoring (SNM) mechanism aiming to reveal the presence of spoofing within an area. Consisting of several receivers and one central processing component, it keeps detecting spoofing even when the network is not attacked. The mechanism is based on the different time difference of arrival (TDOA) properties between spoofing and authentic signals. Normally, TDOAs of spoofing signals from a common spoofer are identical while those of authentic signals from diverse directions are dispersed. The TDOA is measured as the differential pseudorange to carrier frequency ratio (DPF). In a spoofing case, the DPFs include those of both authentic and spoofing signals, among which the DPFs of authentic are dispersed while those of spoofing are almost overlapped. An algorithm is proposed to search for the DPFs that are within a pre-defined small range, and an alarm will be raised if several DPFs are found within such range. The proposed SNM methodology is validated by simulations and a partial field trial. Results show 99.99% detection and 0.01% false alarm probabilities are achieved. The SNM has the potential to be adopted in various applications such as (1) alerting dedicated users when spoofing is occurring, which could significantly shorten the receiver side spoofing cost; (2) in combination with GNSS performance monitoring systems, such as the Continuous Operating Reference System (CORS) and GNSS Availability, Accuracy, Reliability anD Integrity Assessment for Timing and Navigation (GAARDIAN) System, to provide more reliable monitoring services.
Burr, Tom; Croft, Stephen; Jarman, Kenneth D.
2015-09-05
The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings, and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically quantify total uncertainty in terms of “random” and “systematic” components, and then specify error bars for the total mass estimate in multiple items. Uncertainty quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed andmore » achievable using modern statistical methods. To this end, we describe the extent to which the guideline for expressing uncertainty in measurements (GUM) can be used for NDA. Also, we propose improvements over GUM for NDA by illustrating UQ challenges that it does not address, including calibration with errors in predictors, model error, and item-specific biases. A case study is presented using low-resolution NaI spectra and applying the enrichment meter principle to estimate the U-235 mass in an item. The case study illustrates how to update the current American Society for Testing and Materials guide for application of the enrichment meter principle using gamma spectra from a NaI detector.« less
[Cystomanometric study of bladder sensation during sacral neuromodulation test].
Leclers, François; Mourey, Eric; Galas, Jean Marie; Cormier, Luc; Mangin, Philippe
2005-04-01
Prospective clinical and urodynamic study evaluating modification of bladder sensation during sacral neuromodulation (SNM). 24 consecutive patients with non-neurological hyperactive bladder underwent an SNM test. Questioned about their symptoms before and during the test by the urinary handicap assessment scale, patients were divided into two groups: A (improved) and B (not improved). Group A consisted of patients obtaining 50% improvement of their symptoms with SNM followed by return of symptoms at the end of the test, while the other patients constituted group B. We then compared the cystomanometric results according to their clinical response. The mean age was 53 years: 10 patients with a good response constituted group A (n=10, i.e. 42%) and 14 patients with a poor response constituted group B (n=14, i.e. 58%). Clinically, in patients with a good response, SNM decreased urge incontinence by 100%, day-time frequency by 89% and protections by 55%. Urodynamic assessment in group A during the test demonstrated a significant increase of +23% of bladder capacity (p<0.01), +57% of the volume of onset of the first unstable contraction (p<0.004), +83% of bladder volume to the first urge to urinate BI (p<0.001) and +46% to urgency B3 (p<0.04). During SNM, cystometry revealed that 1 or 2 bladder filling volumes were increased at B1 and/or B3 in 100% of improved subjects. In contrast, 1 or 2 volumes decreased at B1 and/or B3 in 58% of non-improved subjects. No significant difference of intensity of unstable contractions was observed between the 2 groups during SNM (p=0.31). A significant correlation was observed between the two methods of clinical and urodynamic assessment. Our results suggest the use of the cystomanometric increase of bladder volume at B1 and B3 as selection criterion for candidates for SNM with non-neurological hyperactive bladder.
Task-discriminative space-by-time factorization of muscle activity
Delis, Ioannis; Panzeri, Stefano; Pozzo, Thierry; Berret, Bastien
2015-01-01
Movement generation has been hypothesized to rely on a modular organization of muscle activity. Crucial to this hypothesis is the ability to perform reliably a variety of motor tasks by recruiting a limited set of modules and combining them in a task-dependent manner. Thus far, existing algorithms that extract putative modules of muscle activations, such as Non-negative Matrix Factorization (NMF), identify modular decompositions that maximize the reconstruction of the recorded EMG data. Typically, the functional role of the decompositions, i.e., task accomplishment, is only assessed a posteriori. However, as motor actions are defined in task space, we suggest that motor modules should be computed in task space too. In this study, we propose a new module extraction algorithm, named DsNM3F, that uses task information during the module identification process. DsNM3F extends our previous space-by-time decomposition method (the so-called sNM3F algorithm, which could assess task performance only after having computed modules) to identify modules gauging between two complementary objectives: reconstruction of the original data and reliable discrimination of the performed tasks. We show that DsNM3F recovers the task dependence of module activations more accurately than sNM3F. We also apply it to electromyographic signals recorded during performance of a variety of arm pointing tasks and identify spatial and temporal modules of muscle activity that are highly consistent with previous studies. DsNM3F achieves perfect task categorization without significant loss in data approximation when task information is available and generalizes as well as sNM3F when applied to new data. These findings suggest that the space-by-time decomposition of muscle activity finds robust task-discriminating modular representations of muscle activity and that the insertion of task discrimination objectives is useful for describing the task modulation of module recruitment. PMID:26217213
Task-discriminative space-by-time factorization of muscle activity.
Delis, Ioannis; Panzeri, Stefano; Pozzo, Thierry; Berret, Bastien
2015-01-01
Movement generation has been hypothesized to rely on a modular organization of muscle activity. Crucial to this hypothesis is the ability to perform reliably a variety of motor tasks by recruiting a limited set of modules and combining them in a task-dependent manner. Thus far, existing algorithms that extract putative modules of muscle activations, such as Non-negative Matrix Factorization (NMF), identify modular decompositions that maximize the reconstruction of the recorded EMG data. Typically, the functional role of the decompositions, i.e., task accomplishment, is only assessed a posteriori. However, as motor actions are defined in task space, we suggest that motor modules should be computed in task space too. In this study, we propose a new module extraction algorithm, named DsNM3F, that uses task information during the module identification process. DsNM3F extends our previous space-by-time decomposition method (the so-called sNM3F algorithm, which could assess task performance only after having computed modules) to identify modules gauging between two complementary objectives: reconstruction of the original data and reliable discrimination of the performed tasks. We show that DsNM3F recovers the task dependence of module activations more accurately than sNM3F. We also apply it to electromyographic signals recorded during performance of a variety of arm pointing tasks and identify spatial and temporal modules of muscle activity that are highly consistent with previous studies. DsNM3F achieves perfect task categorization without significant loss in data approximation when task information is available and generalizes as well as sNM3F when applied to new data. These findings suggest that the space-by-time decomposition of muscle activity finds robust task-discriminating modular representations of muscle activity and that the insertion of task discrimination objectives is useful for describing the task modulation of module recruitment.
An isolated SNM model for high-stability multi-port register file in 65 nm CMOS
NASA Astrophysics Data System (ADS)
Zhang, Yuejun; Wang, Pengjun; Li, Gang
2017-09-01
In modern microprocessors, the multi-port register file is one of the key modules which provides fast and multiple data access for instructions. As the number of access ports in register files increases, stability becomes a key issue due to the voltage fluctuation on bit lines. We propose to apply an isolated inverter to address the voltage fluctuation. To assess the register stability, we derive a closed-form expression of static noise margin (SNM) for our register file. The proposed SNM model can be used as a guideline to predict the impact of several register parameters on the stability and optimize register file designs. To validate the proposed SNM model, we fabricated a test chip of two-write-four-read (2W4R) 1024 bits register file in a TSMC 65 nm low-power CMOS technology. The experimental result shows that the stability of our register file cells with an isolated inverter improve the conventional cells by approximately 2.4 times. Also, the supply voltage causes a fluctuation of SNM of about 65%, while temperature and transistor mismatch cause a fluctuation of SNM of about 20%. Project supported by the National Natural Science Foundation of China (Nos, 61404076, 61474068), the Zhejiang Provincial Natural Science Foundation of China (No. LQ14F040001), the S&T Plan of Zhejiang Provincial Science and Technology Department (No. 2015C31010), the China Spark Program (No. 2015GA701053), the Ningbo Natural Science Foundation (Nos. 2014A610148, 2015A610107), and the K. C. Wong Magna Fund in Ningbo University, China.
Spinelli, Michele; Sievert, Karl-Dietrich
2008-12-01
This article accompanies a "surgery in motion" DVD on sacral neuromodulation (SNM) with InterStim Therapy, which visualizes the implantation of the InterStim II system. The article describes the technical and surgical developments of SNM and their impact on treatment success, safety, and patient's quality of life (QoL). Relevant literature on SNM with regard to technical changes and related clinical outcomes has been reviewed. Since its introduction in the early 1990s, SNM has proven useful in the treatment of several types of chronic urinary (and bowel) dysfunction. Recent technical improvements in devices and, in particular, the introduction of the tined lead 5 yr ago made SNM progress from an elaborate, open-surgery, general anesthesia, one-stage implant procedure to a minimally invasive, local anesthesia, percutaneous technique in two stages. The permanent tined lead implant enables a longer patient testing period (minimum of 14 d recommended) and less lead migration. This has considerably reduced technical failures and improved the success rate of the test phase; the response rate was almost doubled to approximately 80%. These improvements also affected tolerability, resulting in increased QoL for the patient. The use of the recently introduced smaller implantable neurostimulator InterStim II seems to further improve patient comfort and makes the implant procedure for the physician easier and shorter. However, this must be further addressed in clinical studies. SNM with InterStim Therapy using the tined lead offers an efficient treatment modality for patients in whom conservative treatment has failed.
Tagged Neutron Source for API Inspection Systems with Greatly Enhanced Spatial Resolution
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-06-04
We recently developed induced fission and transmission imaging methods with time- and directionally-tagged neutrons offer new capabilities for characterization of fissile material configurations and enhanced detection of special nuclear materials (SNM). An Advanced Associated Particle Imaging (API) generator with higher angular resolution and neutron yield than existing systems is needed to fully exploit these methods.
RPA activates the XPF-ERCC1 endonuclease to initiate processing of DNA interstrand crosslinks.
Abdullah, Ummi B; McGouran, Joanna F; Brolih, Sanja; Ptchelkine, Denis; El-Sagheer, Afaf H; Brown, Tom; McHugh, Peter J
2017-07-14
During replication-coupled DNA interstrand crosslink (ICL) repair, the XPF-ERCC1 endonuclease is required for the incisions that release, or "unhook", ICLs, but the mechanism of ICL unhooking remains largely unknown. Incisions are triggered when the nascent leading strand of a replication fork strikes the ICL Here, we report that while purified XPF-ERCC1 incises simple ICL-containing model replication fork structures, the presence of a nascent leading strand, modelling the effects of replication arrest, inhibits this activity. Strikingly, the addition of the single-stranded DNA (ssDNA)-binding replication protein A (RPA) selectively restores XPF-ERCC1 endonuclease activity on this structure. The 5'-3' exonuclease SNM1A can load from the XPF-ERCC1-RPA-induced incisions and digest past the crosslink to quantitatively complete the unhooking reaction. We postulate that these collaborative activities of XPF-ERCC1, RPA and SNM1A might explain how ICL unhooking is achieved in vivo . © 2017 The Authors. Published under the terms of the CC BY 4.0 license.
Optimization and Characterization of a Novel Self Powered Solid State Neutron Detector
NASA Astrophysics Data System (ADS)
Clinton, Justin
There is a strong interest in detecting both the diversion of special nuclear material (SNM) from legitimate, peaceful purposes and the transport of illicit SNM across domestic and international borders and ports. A simple solid-state detector employs a planar solar-cell type p-n junction and a thin conversion layer that converts incident neutrons into detectable charged particles, such as protons, alpha-particles, and heavier ions. Although simple planar devices can act as highly portable, low cost detectors, they have historically been limited to relatively low detection efficiencies; ˜10% and ˜0.2% for thermal and fast detectors, respectively. To increase intrinsic detection efficiency, the incorporation of 3D microstructures into p-i-n silicon devices was proposed. In this research, a combination of existing and new types of detector microstructures were investigated; Monte Carlo models, based on analytical calculations, were constructed and characterized using the GEANT4 simulation toolkit. The simulation output revealed that an array of etched hexagonal holes arranged in a honeycomb pattern and filled with either enriched (99% 10B) boron or parylene resulted in the highest intrinsic detection efficiencies of 48% and 0.88% for thermal and fast neutrons, respectively. The optimal parameters corresponding to each model were utilized as the basis for the fabrication of several prototype detectors. A calibrated 252Cf spontaneous fission source was utilized to generate fast neutrons, while thermal neutrons were created by placing the 252Cf in an HDPE housing designed and optimized using the MCNP simulation software. Upon construction, thermal neutron calibration was performed via activation analysis of gold foils and measurements from a 6Li loaded glass scintillator. Experimental testing of the prototype detectors resulted in maximum intrinsic efficiencies of 4.5 and 0.12% for the thermal and fast devices, respectively. The prototype thermal device was filled with natural (19% 10B) boron; scaling the response to 99% 10B enriched boron resulted in an intrinsic efficiency of 22.5%, one of the highest results in the literature. A comparison of simulated and experimental detector responses demonstrated a high degree of correlation, validating the conceptual models.
32 CFR Appendix B to Part 223 - Guidelines for the Determination of DoD UCNI
Code of Federal Regulations, 2011 CFR
2011-07-01
... Systems a. Information on the layout or design of security and alarm systems at a specific DoD SNM.... Frequency and schedule of DoD SNM inventories. 3. Facility Description a. Maps, conceptual design, and...
32 CFR Appendix B to Part 223 - Guidelines for the Determination of DoD UCNI
Code of Federal Regulations, 2012 CFR
2012-07-01
... Systems a. Information on the layout or design of security and alarm systems at a specific DoD SNM.... Frequency and schedule of DoD SNM inventories. 3. Facility Description a. Maps, conceptual design, and...
32 CFR Appendix B to Part 223 - Guidelines for the Determination of DoD UCNI
Code of Federal Regulations, 2010 CFR
2010-07-01
... Systems a. Information on the layout or design of security and alarm systems at a specific DoD SNM.... Frequency and schedule of DoD SNM inventories. 3. Facility Description a. Maps, conceptual design, and...
Detection of special nuclear materials with the associate particle technique
NASA Astrophysics Data System (ADS)
Carasco, Cédric; Deyglun, Clément; Pérot, Bertrand; Eléon, Cyrille; Normand, Stéphane; Sannié, Guillaume; Boudergui, Karim; Corre, Gwenolé; Konzdrasovs, Vladimir; Pras, Philippe
2013-04-01
In the frame of the French trans-governmental R&D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.
Neutron kinetics in moderators and SNM detection through epithermal-neutron-induced fissions
NASA Astrophysics Data System (ADS)
Gozani, Tsahi; King, Michael J.
2016-01-01
Extension of the well-established Differential Die Away Analysis (DDAA) into a faster time domain, where more penetrating epithermal neutrons induce fissions, is proposed and demonstrated via simulations and experiments. In the proposed method the fissions stimulated by thermal, epithermal and even higher-energy neutrons are measured after injection of a narrow pulse of high-energy 14 MeV (d,T) or 2.5 MeV (d,D) source neutrons, appropriately moderated. The ability to measure these fissions stems from the inherent correlation of neutron energy and time ("E-T" correlation) during the process of slowing down of high-energy source neutrons in common moderating materials such as hydrogenous compounds (e.g., polyethylene), heavy water, beryllium and graphite. The kinetic behavior following injection of a delta-function-shaped pulse (in time) of 14 MeV neutrons into such moderators is studied employing MCNPX simulations and, when applicable, some simple "one-group" models. These calculations served as a guide for the design of a source moderator which was used in experiments. Qualitative relationships between slowing-down time after the pulse and the prevailing neutron energy are discussed. A laboratory system consisting of a 14 MeV neutron generator, a polyethylene-reflected Be moderator, a liquid scintillator with pulse-shape discrimination (PSD) and a two-parameter E-T data acquisition system was set up to measure prompt neutron and delayed gamma-ray fission signatures in a 19.5% enriched LEU sample. The measured time behavior of thermal and epithermal neutron fission signals agreed well with the detailed simulations. The laboratory system can readily be redesigned and deployed as a mobile inspection system for SNM in, e.g., cars and vans. A strong pulsed neutron generator with narrow pulse (<75 ns) at a reasonably high pulse frequency could make the high-energy neutron induced fission modality a realizable SNM detection technique.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... Electric Company, LLC, Hematite Decommissioning Project, Hematite, MO AGENCY: Nuclear Regulatory Commission... (SNM) License number SNM-33, issued to Westinghouse Electric Company, LLC (WEC) to authorize... radioactively contaminated material by rail car to an offsite facility located in Idaho was also confirmed in...
Sacral nerve stimulation for neuromodulation of the lower urinary tract.
Hubsher, Chad P; Jansen, Robert; Riggs, Dale R; Jackson, Barbara J; Zaslau, Stanley
2012-10-01
Sacral neuromodulation (SNM) has become a standard treatment option for patients suffering from urinary urge incontinence, urgency-frequency, and/or nonobstructive urinary retention refractory to conservative and pharmacologic treatment. Since its initial development, the manufacturer of InterStim therapy (Medtronic, Inc., Minneapolis, MN, USA), has introduced technical modifications, while surgeons and researchers have adapted and published various innovations and alterations of the implantation technique. In this article, we feature our SNM technique including patient selection, comprehensive dialogue/evaluation, procedure details, and appropriate follow up. Although there is often great variability in patients with lower urinary tract dysfunction, we maintain that great success can be achieved with a systematic and methodical approach to SNM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bertozzi, William; Hasty, Richard; Klimenko, Alexei
Four new technologies have been developed for use in non-intrusive inspection systems to detect nuclear materials, explosives and contraband. Nuclear Resonance Fluorescence (NRF) provides a three dimensional image of the isotopic content of a container. NRF determines the isotopic composition of a region and specifies the isotopic structure of the neighboring regions, thus providing the detailed isotopic composition of any threat. In transmission mode, NRF provides a two dimensional projection of the isotopic content of a container, much as standard X-ray radiography provides for density. The effective-Z method (EZ-3D) uses electromagnetic scattering processes to yield a three-dimensional map of themore » effective-Z and the density in a container. The EZ-3D method allows for a rapid discrimination based on effective Z and mass of materials such as those with high Z, as well as specifying regions of interest for other contraband. The energy spectrum of prompt neutrons from photon induced fission (PNPF) provides a unique identification of the presence of actinides and SNM. These four new technologies can be used independently or together to automatically determine the presence of hazardous materials or contraband. They can also be combined with other technologies to provide added specificity.« less
A Prototype Large Area Detector Module for Muon Scattering Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steer, C.A.; Boakes, J.; Burns, J.
Abstract-Shielded special nuclear materials (SNM) are of concern as some fissile isotopes have low gamma and neutron emission rates. These materials are also easily shielded to the point where their passive emissions are comparable to background. Consequently, shielded SNM is very challenging for passive radiation detection portals which scan cargo containers. One potential solution for this is to utilise the natural cosmic ray muon background and examine how these muons scatter from materials inside the container volume, terms; the muon scattering tomography (MST) technique measures the three-dimensional localised scattering at all points within a cargo container, providing a degree ofmore » material discrimination. There is the additional benefit that the MST signal increases with the presence of more high density shielding materials, in contrast to passive radiation detection. Simulations and calculations suggest that the effectiveness of the technique is sensitive to the tracking accuracy amongst other parameters, motivating the need to develop practical detector systems that are capable of tracking cosmic ray muons. To this end, we have constructed and tested a 2 m by 2 m demonstration module based on gaseous drift chambers and triggered by a large area scintillator-based detector, which is readout by wavelength shifting fibres. We discuss its design, construction, characterisation and operational challenges. (authors)« less
Hasirci, A. Sait; Maldonado-Devincci, Antoniette M.; Beattie, Matthew C.; O'Buckley, Todd K.; Morrow, A. Leslie
2016-01-01
Background The GABAergic neuroactive steroid (3α,5α)-3-hydroxy-pregnan-20-one (3α,5α-THP, allopregnanolone) enhances GABAergic activity and produces subjective effects similar to ethanol. The effect of chronic alcohol exposure on 3α,5α-THP concentrations has been studied in mouse, rat, and monkey limbic brain areas. Chronic ethanol exposure produced divergent brain region and cell specific changes in 3α,5α-THP concentrations in animal studies. However, 3α,5α-THP levels in similar human brain regions have never been examined in individuals diagnosed with alcohol use disorder (AUD). Therefore, we used immunohistochemistry to examine 3α,5α-THP levels in the ventral tegmental area (VTA), substantia nigra pars medialis (SNM), and amygdala of human postmortem brains of patients diagnosed with AUD compared to social drinkers. The effects of sex and liver disease on 3α,5α-THP concentrations were examined in the aforementioned brain regions. Methods Human postmortem brains of AUD patients and age-matched controls were obtained from the New South Wales Brain Tissue Resource Center. Immunohistochemistry was performed using anti-3α,5α-THP antibody on formalin fixed and paraffin embedded brain sections to detect cellular 3α,5α-THP levels. Immunoreactivity was analyzed by pixel density/mm2 for the comparison between AUD patients and controls. Results 3α,5α-THP immunoreactivity was increased by 23.2±9% in the VTA of AUD patients compared to age matched controls (p= 0.014). Moreover, a 29.6±10% increase in 3α,5α-THP immunoreactivity was observed in the SNM of male AUD patients compared to male controls (p<0.01), but not in female subjects. 3α,5α-THP immunoreactivity in the VTA and SNM regions did not differ between non-cirrhotic and cirrhotic AUD patients. A sex difference in 3α,5α-THP immunoreactivity (female 51±18% greater than male) was observed among control subjects in the SNM, but no other brain region. 3α,5α-THP immunoreactivity in the basolateral and lateral amygdala were negatively correlated with the length of the tissue fixation time as well as the age of the subjects, precluding assessment of the effect of AUD. Conclusions Cellular 3α,5α-THP levels in VTA are increased in human AUD patients, an effect that is likely independent of sex and liver disease. The differences between animal models and human studies should be factored into the interpretation of the physiological significance of elevated 3α,5α-THP levels in humans. PMID:28068457
van Voskuilen, A C; Oerlemans, D J; Gielen, N; Lansen-Koch, S M P; Weil, E H J; van Lankveld, J J D M; van den Hombergh, U; Baeten, C G M I; van Kerrenbroeck, P E V
2012-01-01
To determine whether sacral neuromodulation (SNM) for urinary symptoms or fecal incontinence gives improvement of female sexual function and whether improvement is due to physiological or psychological factors. Between 2002 and 2008, 8 patients had an array of questionnaires before and after SNM implantation. The questionnaires were: the Questionnaire for Screening for Sexual Dysfunctions, the Golombok Rust Inventory of Sexual Satisfaction, the Symptom Checklist-90, the Maudsley Marital Questionnaire and the McGill-Mah Orgasm Questionnaire. Three of these 8 patients underwent vaginal plethysmography before and after implantation. No statistically significant changes were found, although there seems to be a trend toward improvement in orgasm scores. In plethysmography all 3 patients showed increased vaginal pulse amplitude with the stimulator turned on with both erotic and non-erotic stimuli. This study does not show a clear effect of SNM on sexual function, although there seems to be an improvement in orgasm scores. The lack of response on psychological questionnaires and the increase in vaginal pulse amplitude after SNM implantation indicate that there might be a physiological response. Copyright © 2012 S. Karger AG, Basel.
Duelund-Jakobsen, Jakob; van Wunnik, Bart; Buntzen, Steen; Lundby, Lilli; Laurberg, Søren; Baeten, Cor
2014-07-01
Sacral neuromodulation (SNM) is an established treatment for fecal incontinence (FI). A recent study from our group found that the relationship between patient satisfaction and clinical outcome is complex and does not match the traditional used success criteria. Therefore, the ability to predict patient satisfaction must be given priority. The aim of the present study is to identify baseline factors predictive of patient satisfaction, with SNM, for idiopathic FI. We analyzed data from patients treated with SNM for idiopathic FI in Aarhus, Denmark, and Maastricht, The Netherlands. A questionnaire considering self-reported satisfaction was mailed to these patients and compared to baseline characteristics. Logistic regression was used to determine the predictive value of baseline demographic and diagnostic variables. In total, 131 patients were included in the analysis. Patient satisfaction with the current treatment result was reported in 75 patients. Fifty-six patients were dissatisfied with SNM treatment, after median 46 months (range 11-122) with permanent implantation. Pudendal nerve terminal motor latency (PNTML) was the solely identified predictor for long-term patient satisfaction. A subgroup univariate-logistic regression analysis showed that PNTML ≤ 2.3 ms at the side of lead implantation was a statistically significant predictor for patient satisfaction (odds ratio (OR) 2.3, 95% confidence interval (CI) 1.01-5.24, p = 0.048). Baseline PNTML measurement may be predictive of long-term satisfaction with SNM therapy for idiopathic FI. Further studies are needed to confirm this result.
Sacral neuromodulation for lower urinary tract dysfunction and impact on erectile function.
Lombardi, Giuseppe; Mondaini, Nicola; Giubilei, Gianluca; Macchiarella, Angelo; Lecconi, Filippo; Del Popolo, Giulio
2008-09-01
The first sacral nerve stimulators were for urinary urgency incontinence, urgency-frequency, and nonobstructive urinary retention. Since then, observations have been made for benefits beyond voiding disorders. To evaluate if sacral neuromodulation (SNM) using the InterStim system (Medtronic Inc., Minneapolis, MN, USA) improves erectile function. From January 1999 to January 2007, 54 males, mean age 42.8, underwent a permanent SNM for lower urinary tract symptoms (LUTS). Pre-SNM only subjects with concomitant erectile impairment according to the five-item version of the International Index of Erectile Function (IIEF-5), with normal blood sexual hormonal status, and responding to an intracavernous injection test 10 microg were enrolled in our study. Three months after permanent implantation, the IIEF-5 was completed again. Those who benefited significantly in erectile function completed the IIEF-5 semiannually. A final checkup was performed in July 2007. A score of IIEF-5 equal to or higher than 25% compared to baseline indicated remarkable clinical enhancement. Presurgery, two patients were excluded. Overall, 22 subjects (42.3%) showed erectile impairment (14 were neurogenic). In the first visit post-SNM, five retentionists of neurogenic origin and two with overactive bladder syndrome of idiopathic origin achieved noticeable erectile improvement. Their median IIEF-5 score shifted from 14.6 to 22.2, and 15.5 to 22.5, respectively. During follow-up, two neurogenics lost the benefits concerning voiding and erection and recovered them after a new implant in the contralateral sacral S3 root. In the final visit, the seven responders reached an IIEF-5 score of at least 22. Our study showed a clinically important benefit of sexual function mainly for neurogenic retentionists. Future research should test SNM in a larger sample of subjects, exclusively with sexual dysfunctions, in order to better understand the mechanism of action of SNM on erectile function.
Otto, W; Nowrotek, A; Burger, M; Wieland, W F; Rößler, W; Denzinger, S
2012-05-01
Lower urinary tract symptoms (LUTS) are a common and multiform micturition disorder of various possible origins. Several second-line techniques are available in the event of first-line medicinal treatment failure. These include the intravesical injection of Botulinum toxin, bladder augmentation and sacral neuromodulation (SNM). This study presents current data and results from a prospective study of patients with LUTS of various aetiologies. Clinical success was investigated for all patients who underwent SNM for LUTS with or without urge incontinence caused by chronic pelvic pain syndrome, multiple sclerosis and idiopathic disease between May 2007 and December 2010. The preoperatively determined symptoms were compared with current follow-up data. Median follow-up time was 11 months (1 - 43). A total of 47 patients were indicated for SNM over the investigated period. 80.9 % were female, median patient age was 67 years (19 - 84). The testing phase was successful in 38 cases (80.9 %) with 9 electrodes being explanted (19.1 %). In the case of idiopathic LUTS we could show a statistically significant increase of micturition volume and reduction of incontinence pad use. There was no statistically significant improvement of any micturition parameter for patients with multiple sclerosis, patients with chronic pelvic pain syndrome showed a statistically significant reduction of micturition frequency and a subjective improvement of symptoms in 75 %. In the selected patient groups SNM is a promising and, in experienced hands, a low-complication second-line therapy for the treatment of LUTS of idiopathic aetiology. However, the general recommendation of SNM for multiple sclerosis and chronic pelvic pain syndrome patients cannot be given on the basis of our results. Further prospective, randomised multicentre studies are need to further refine the indications for SNM in LUTS of neurogenic and non-neurogenic origins. © Georg Thieme Verlag KG Stuttgart · New York.
Sorokine, Alexandre; Schlicher, Bob G.; Ward, Richard C.; ...
2015-05-22
This paper describes an original approach to generating scenarios for the purpose of testing the algorithms used to detect special nuclear materials (SNM) that incorporates the use of ontologies. Separating the signal of SNM from the background requires sophisticated algorithms. To assist in developing such algorithms, there is a need for scenarios that capture a very wide range of variables affecting the detection process, depending on the type of detector being used. To provide such a cpability, we developed an ontology-driven information system (ODIS) for generating scenarios that can be used in creating scenarios for testing of algorithms for SNMmore » detection. The ontology-driven scenario generator (ODSG) is an ODIS based on information supplied by subject matter experts and other documentation. The details of the creation of the ontology, the development of the ontology-driven information system, and the design of the web user interface (UI) are presented along with specific examples of scenarios generated using the ODSG. We demonstrate that the paradigm behind the ODSG is capable of addressing the problem of semantic complexity at both the user and developer levels. Compared to traditional approaches, an ODIS provides benefits such as faithful representation of the users' domain conceptualization, simplified management of very large and semantically diverse datasets, and the ability to handle frequent changes to the application and the UI. Furthermore, the approach makes possible the generation of a much larger number of specific scenarios based on limited user-supplied information« less
Radiation Detection at Borders for Homeland Security
NASA Astrophysics Data System (ADS)
Kouzes, Richard
2004-05-01
Countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders at land, rail, air, and sea ports of entry. These efforts include deployments in the US and a number of European and Asian countries by governments and international agencies. Items of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. Some cargo contains naturally occurring radioactive material (NORM) that triggers "nuisance" alarms in RPMs at these border crossings. Individuals treated with medical radiopharmaceuticals also produce nuisance alarms and can produce cross-talk between adjacent lanes of a multi-lane deployment. The operational impact of nuisance alarms can be significant at border crossings. Methods have been developed for reducing this impact without negatively affecting the requirements for interdiction of radioactive materials of interest. Plastic scintillator material is commonly used in RPMs for the detection of gamma rays from radioactive material, primarily due to the efficiency per unit cost compared to other detection materials. The resolution and lack of full-energy peaks in the plastic scintillator material prohibits detailed spectroscopy. However, the limited spectroscopic information from plastic scintillator can be exploited to provide some discrimination. Energy-based algorithms used in RPMs can effectively exploit the crude energy information available from a plastic scintillator to distinguish some NORM. Whenever NORM cargo limits the level of the alarm threshold, energy-based algorithms produce significantly better detection probabilities for small SNM sources than gross-count algorithms. This presentation discusses experience with RPMs for interdiction of radioactive materials at borders.
32 CFR Appendix A to Part 223 - Procedures for Identifying and Controlling DoD UCNI
Code of Federal Regulations, 2010 CFR
2010-07-01
... security measures, including security plans, procedures, and equipment, for the physical protection of DoD... sabotage of DoD SNM, equipment, or facilities (e.g., relative importance of a facility or the location... equipment, for the physical protection of DoD SNM, equipment, or facilities. c. Meet the adverse effects...
Special Nuclear Material Gamma-Ray Signatures for Reachback Analysts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karpius, Peter Joseph; Myers, Steven Charles
2016-08-29
These are slides on special nuclear material gamma-ray signatures for reachback analysts for an LSS Spectroscopy course. The closing thoughts for this presentation are the following: SNM materials have definite spectral signatures that should be readily recognizable to analysts in both bare and shielded configurations. One can estimate burnup of plutonium using certain pairs of peaks that are a few keV apart. In most cases, one cannot reliably estimate uranium enrichment in an analogous way to the estimation of plutonium burnup. The origin of the most intense peaks from some SNM items may be indirect and from ‘associated nuclides.' Indirectmore » SNM signatures sometimes have commonalities with the natural gamma-ray background.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
...: Submission for the Office of Management and Budget (OMB) Review; Comment Request AGENCY: Nuclear Regulatory... Control and Accounting of Special Nuclear Material. 3. Current OMB approval number: 3150-0123. 4. The form... requirements for material control and accounting of SNM, and specific performance-based regulations for...
Active interrogation of highly enriched uranium
NASA Astrophysics Data System (ADS)
Fairrow, Nannette Lea
Safeguarding special nuclear material (SNM) in the Department of Energy Complex is vital to the national security of the United States. Active and passive nondestructive assays are used to confirm the presence of SNM in various configurations ranging from waste to nuclear weapons. Confirmation measurements for nuclear weapons are more challenging because the design complicates the detection of a distinct signal for highly enriched uranium. The emphasis of this dissertation was to investigate a new nondestructive assay technique that provides an independent and distinct signal to confirm the presence of highly enriched uranium (HEU). Once completed and tested this assay method could be applied to confirmation measurements of nuclear weapons. The new system uses a 14-MeV neutron source for interrogation and records the arrival time of neutrons between the pulses with a high efficiency detection system. The data is then analyzed by the Feynman reduced variance method. The analysis determined the amount of correlation in the data and provided a unique signature of correlated fission neutrons. Measurements of HEU spheres were conducted at Los Alamos with the new system. Then, Monte Carlo calculations were performed to verify hypothesis made about the behavior of the neutrons in the experiment. Comparisons of calculated counting rates by the Monte Carlo N-Particle Transport Code (MCNP) were made with the experimental data to confirm that the measured response reflected the desired behavior of neutron interactions in the highly enriched uranium. In addition, MCNP calculations of the delayed neutron build-up were compared with the measured data. Based on the results obtained from this dissertation, this measurement method has the potential to be expanded to include mass determinations of highly enriched uranium. Although many safeguards techniques exist for measuring special nuclear material, the number of assays that can be used to confirm HEU in shielded systems is limited. These assays also rely on secondary characteristics of the material to be measured. A review of the nondestructive techniques with potential applications for nuclear weapons confirmatory measurements were evaluated with summaries of the pros and cons involved in implementing the methods at production type facilities.
Cui, Z; Wang, Z; Ye, G; Zhang, C; Wu, G; Lv, J
2018-01-01
The aim was to test the feasibility of a novel three-dimensional (3D) printed guiding device for electrode implantation of sacral neuromodulation (SNM). A 3D printed guiding device for electrode implantation was customized to patients' anatomy of the sacral region. Liquid photopolymer was selected as the printing material. The details of the device designation and prototype building are described. The guiding device was used in two patients who underwent SNM for intractable constipation. Details of the procedure and the outcomes are given. With the help of the device, the test needle for stimulation was placed in the target sacral foramen successfully at the first attempt of puncture in both patients. The time to implant a tined SNM electrode was less than 20 min and no complications were observed. At the end of the screening phase, symptoms of constipation were relieved by more than 50% in both patients and permanent stimulation was established. The customized 3D printed guiding device for implantation of SNM is a promising instrument that facilitates a precise and quick implantation of the electrode into the target sacral foramen. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
Total Ionizing Dose Influence on the Single-Event Upset Sensitivity of 130-nm PD SOI SRAMs
NASA Astrophysics Data System (ADS)
Zheng, Qiwen; Cui, Jiangwei; Liu, Mengxin; Zhou, Hang; Liu, Mohan; Wei, Ying; Su, Dandan; Ma, Teng; Lu, Wu; Yu, Xuefeng; Guo, Qi; He, Chengfa
2017-07-01
Effect of total ionizing dose (TID) on single-event upset (SEU) hardness of 130 nm partially depleted (PD) silicon-on-insulator (SOI) static random access memories (SRAMs) is investigated in this paper. The measurable synergistic effect of TID on SEU sensitivity of 130-nm PD SOI SRAM was observed in our experiment, even though that is far less than micrometer and submicrometer devices. Moreover, SEU cross section after TID irradiation has no dependence on the data pattern that was applied during TID exposure: SEU cross sections are characterized by TID data pattern and its complement data pattern are decreased consistently rather than a preferred state and a nonpreferred state as micrometer and sub-micrometer SRAMs. The memory cell test structure allowing direct measurement of static noise margin (SNM) under standby operation was designed using identical memory cell layout of SRAM. Direct measurement of the memory cell SNM shows that both data sides' SNM is decreased by TID, indicating that SEU cross section of 130-nm PD SOI SRAM will be increased by TID. And, the decreased SNM is caused by threshold shift in memory cell transistors induced by “radiation-induced narrow channel effect”.
DNDO Report: Predicting Solar Modulation Potentials for Modeling Cosmic Background Radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Behne, Patrick Alan
The modeling of the detectability of special nuclear material (SNM) at ports and border crossings requires accurate knowledge of the background radiation at those locations. Background radiation originates from two main sources, cosmic and terrestrial. Cosmic background is produced by high-energy galactic cosmic rays (GCR) entering the atmosphere and inducing a cascade of particles that eventually impact the earth’s surface. The solar modulation potential represents one of the primary inputs to modeling cosmic background radiation. Usosokin et al. formally define solar modulation potential as “the mean energy loss [per unit charge] of a cosmic ray particle inside the heliosphere…” Modulationmore » potential, a function of elevation, location, and time, shares an inverse relationship with cosmic background radiation. As a result, radiation detector thresholds require adjustment to account for differing background levels, caused partly by differing solar modulations. Failure to do so can result in higher rates of false positives and failed detection of SNM for low and high levels of solar modulation potential, respectively. This study focuses on solar modulation’s time dependence, and seeks the best method to predict modulation for future dates using Python. To address the task of predicting future solar modulation, we utilize both non-linear least squares sinusoidal curve fitting and cubic spline interpolation. This material will be published in transactions of the ANS winter meeting of November, 2016.« less
Linac based photofission inspection system employing novel detection concepts
NASA Astrophysics Data System (ADS)
Stevenson, John; Gozani, Tsahi; Elsalim, Mashal; Condron, Cathie; Brown, Craig
2011-10-01
Rapiscan Systems is developing a LINAC based cargo inspection system for detection of special nuclear material (SNM) in cargo containers. The system, called Photofission Based Alarm Resolution (PBAR) is being developed under a DHD/DNDO Advanced Technology Demonstration (ATD) program. The PBAR system is based on the Rapiscan Eagle P9000 X-ray system, which is a portal system with a commercial 9 MeV LINAC X-ray source. For the purposes of the DNDO ATD program, a conveyor system was installed in the portal to allow scanning and precise positioning of 20 ft ISO cargo containers. The system uses a two step inspection process. In the first step, the basic scan, the container is quickly and completely inspected using two independent radiography arrays: the conventional primary array with high spatial resolution and a lower resolution spectroscopic array employing the novel Z-Spec method. The primary array uses cadmium tungstate (CdWO 4) detectors with conventional current mode readouts using photodiodes. The Z-Spec array uses small plastic scintillators capable of performing very fast (up to 10 8 cps) gamma-ray spectroscopy. The two radiography arrays are used to locate high-Z objects in the image such as lead, tungsten, uranium, which could be potential shielding materials as well as SNM itself. In the current system, the Z-Spec works by measuring the energy spectrum of transmitted X-rays. For high-Z materials the higher end of the energy spectrum is more attenuated than for low-Z materials and thus has a lower mean energy and a narrower width than low- and medium-Z materials. The second step in the inspection process is the direct scan or alarm clearing scan. In this step, areas of the container image, which were identified as high Z, are re-inspected. This is done by precisely repositioning the container to the location of the high-Z object and performing a stationary irradiation of the area with X-ray beam. Since there are a large number of photons in the 9 MV Bremsstrahlung spectrum above the photofission "threshold" of about 6 MeV, the X-ray beam induces numerous fissions if nuclear material is present. The PBAR system looks for the two most prolific fission signatures to confirm the presence of special nuclear materials (SNM). These are prompt neutrons and delayed gamma rays. The PBAR system uses arrays of two types of fast and highly efficient gamma ray detectors: plastic and fluorocarbon scintillators. The latter serves as a detector of fission prompt neutrons using the novel threshold activation detector (TAD) concept as well as a very efficient delayed gamma ray detector. The major advantage of TAD for detecting the prompt neutrons is its insensitivity to the intense source related backgrounds. The current status of the system and experimental results will be shown and discussed.
Roulette, Pauline; Castel-Lacanal, Evelyne; Sanson, Sylvain; Caremel, Romain; Phé, Véronique; Bart, Stéphane; Duchêne, Franck; De Sèze, Marianne; Even, Alexia; Manunta, Andréa; Scheiber-Nogueira, Maria C; Mouracade, Pascal; Loche, Catherine-Marie; Chartier-Kastler, Emmanuel; Ruffion, Alain; Karsenty, Gilles; Gamé, Xavier
2018-02-01
To assess the impact of sacral neuromodulation (SNM) on pregnancy and vice-versa, by identifying women who had received SNM for lower-urinary tract symptoms (LUTS) and had become pregnant. A cross-sectional descriptive study was carried out based on responses to an on-line questionnaire sent to practitioners listed on the InterStim enCaptureTM National Registry. Questions were related to pre-pregnancy health and SNM efficacy, deactivation of the device, its impact on LUTS, childbirth, the infant, its reactivation and postpartum effectiveness. Twenty-seven pregnancies were recorded among 21 women. Six women had had a pregnancy prior to implantation, two of whom had had a c-section. A total of 18.5% of women had the device disabled prior to conception. The others had their device disabled during the first trimester and did not reactivate it before delivery. Complications were reported in 25.9% of pregnancies: six women had urinary infections, including three of the four treated for chronic retention of urine (CRU), and 1 woman had pain at the stimulation site. There were 24 live births (including one premature birth and four c-sections), one spontaneous miscarriage and two voluntary interruptions of pregnancy. No neonatal disorders have been reported. Effectiveness of sacral neuromodulation decreased in 20% in postpartum. In 27 pregnancies established during SNM for LUTS, 18.5% of patients deactivated their case before pregnancy and the others switched it off during the first trimester. Three-quarters of women with CRU had urinary infection. No adverse effects on fetuses were found. SNM effectiveness deteriorated in 20% cases after childbirth. © 2017 Wiley Periodicals, Inc.
Rahnama'i, Mohammad S; Marcelissen, Tom; Apostolidis, Apostolos; Veit-Rubin, Nikolaus; Schurch, Brigitte; Cardozo, Linda; Dmochowski, Roger
2018-01-24
This manuscript aims to address the evidence availale in the literature on the efficacy of Botulinum Toxin A (BoNT-A) and sacral neuromodulation (SNM) in patients suffering from Interstitial Cystitis (IC)/BPS and propose further research to identify mechanisms of action and establish the clinical efficacy of either therapy. At the International Consultation on Incontinence-Research Society (ICI-RS) in 2017, a panel of Functional Urologists and Urogynaecologists participated in a Think Tank (TT) discussing the management of IC/BPS by BoNT-A and SNM, using available data from both PubMed and Medicine literature searches. The role of BoNT-A and SNM in the treatment of IC/BPS are discussed and mechanisms of actions are proposed. Despite the available randomized trial data on the effect of intravesical BoNT-A treatment on symptoms of IC/BPS, a consistent conclusion of a positive effect cannot be drawn at the moment, as the published studies are small and heterogeneous in design. There is substantive evidence for the positive effects of SNM on symptoms of IC/BPS patients however, during patient selection, it is important to distinguish the degree and the location of pain in order to tailor the best therapy to the right patients. Both intravesical BoNT-A treatment and SNM have been shown to have positive effects in patients with IC/BPS. However, firm conclusions cannot yet be drawn. Patient-reported outcomes and quality of life should be assessed in addition to urinary and pain symptoms. Since current treatments mainly focus on symptomatic relief, future research should also focus on clarifying the pathogenic mechanisms involved in IC/BPS. © 2018 Wiley Periodicals, Inc.
Noblett, Karen L; Dmochowski, Roger R; Vasavada, Sandip P; Garner, Abigail M; Liu, Shan; Pietzsch, Jan B
2017-03-01
Sacral neuromodulation (SNM) is a guideline-recommended third-line treatment option for managing overactive bladder. Current SNM devices are not rechargeable, and require neurostimulator replacement every 3-6 years. Our study objective was to assess potential cost effects to payers of adopting a rechargeable SNM neurostimulator device. We constructed a cost-consequence model to estimate the costs of long-term SNM-treatment with a rechargeable versus non-rechargeable device. Costs were considered from the payer perspective at 2015 reimbursement levels. Adverse events, therapy discontinuation, and programming rates were based on the latest published data. Neurostimulator longevity was assumed to be 4.4 and 10.0 years for non-rechargeable and rechargeable devices, respectively. A 15-year horizon was modeled, with costs discounted at 3% per year. Total budget impact to the United States healthcare system was estimated based on the computed per-patient cost findings. Over the 15-year horizon, per-patient cost of treatment with a non-rechargeable device was $64,111 versus $36,990 with a rechargeable device, resulting in estimated payer cost savings of $27,121. These cost savings were found to be robust across a wide range of scenarios. Longer analysis horizon, younger patient age, and longer rechargeable neurostimulator lifetime were associated with increased cost savings. Over a 15-year horizon, adoption of a rechargeable device strategy was projected to save the United States healthcare system up to $12 billion. At current reimbursement rates, our analysis suggests that rechargeable neurostimulator SNM technology for managing overactive bladder syndrome may deliver significant cost savings to payers over the course of treatment. Neurourol. Urodynam. 36:727-733, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Henderson, Brian S.; Lee, Hin Y.; MacDonald, Thomas D.; Nelson, Roberts G.; Danagoulian, Areg
2018-04-01
The smuggling of special nuclear materials (SNMs) through international borders could enable nuclear terrorism and constitutes a significant threat to global security. This paper presents the experimental demonstration of a novel radiographic technique for quantitatively reconstructing the density and type of material present in commercial cargo containers, as a means of detecting such threats. Unlike traditional techniques which use sources of bremsstrahlung photons with a continuous distribution of energies, multiple monoenergetic gamma radiography utilizes monoenergetic photons from nuclear reactions, specifically the 4.4 and 15.1 MeV photons from the 11B(d,nγ)12C reaction. By exploiting the Z-dependence of the photon interaction cross sections at these two specific energies, it is possible to simultaneously determine the areal density and the effective atomic number as a function of location for a 2D projection of a scanned object. The additional information gleaned from using and detecting photons of specific energies for radiography substantially increases the resolving power between different materials. This paper presents results from the imaging of mock cargo materials ranging from Z ≈5 -92 , demonstrating accurate reconstruction of the effective atomic number and areal density of the materials over the full range. In particular, the system is capable of distinguishing pure materials with Z ≳ 70 , such as lead and uranium—a critical requirement of a system designed to detect SNM. This methodology could be used to screen commercial cargoes with high material specificity, to distinguish most benign materials from SNM, such as uranium and plutonium.
Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo
NASA Astrophysics Data System (ADS)
Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.; Kouzes, Richard T.; Kulisek, Jonathan A.; Robinson, Sean M.; Wittman, Richard A.
2015-10-01
Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide an estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.
NASA Astrophysics Data System (ADS)
Blanpied, Gary; Kumar, Sankaran; Dorroh, Dustin; Morgan, Craig; Blanpied, Isabelle; Sossong, Michael; McKenney, Shawn; Nelson, Beth
2015-06-01
Reported is a new method to apply cosmic-ray tomography in a manner that can detect and characterize not only dense assemblages of heavy nuclei (like Special Nuclear Materials, SNM) but also assemblages of medium- and light-atomic-mass materials (such as metal parts, conventional explosives, and organic materials). Characterization may enable discrimination between permitted contents in commerce and contraband (explosives, illegal drugs, and the like). Our Multi-Mode Passive Detection System (MMPDS) relies primarily on the muon component of cosmic rays to interrogate Volumes of Interest (VOI). Muons, highly energetic and massive, pass essentially un-scattered through materials of light atomic mass and are only weakly scattered by conventional metals used in industry. Substantial scattering and absorption only occur when muons encounter sufficient thicknesses of heavy elements characteristic of lead and SNM. Electrons are appreciably scattered by light elements and stopped by sufficient thicknesses of materials containing medium-atomic-mass elements (mostly metals). Data include simulations based upon GEANT and measurements in the HMT (Half Muon Tracker) detector in Poway, CA and a package scanner in both Poway and Socorro NM. A key aspect of the present work is development of a useful parameter, designated the "stopping power" of a sample. The low-density regime, comprising organic materials up to aluminum, is characterized using very little scattering but a strong variation in stopping power. The medium-to-high density regime shows a larger variation in scattering than in stopping power. The detection of emitted gamma rays is another useful signature of some materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
HERZOG, K.R.
1999-09-01
A review of the environmental, safety, and health vulnerabilities associated with the continued storage of PFP's inventory of plutonium bearing materials and other SNM. This report re-evaluates the five vulnerabilities identified in 1994 at the PFP that are associated with SNM storage. This new evaluation took a more detailed look and applied a risk ranking process to help focus remediation efforts.
NUCLEAR MATERIAL ATTRACTIVENESS: AN ASSESSMENT OF MATERIAL ASSOCIATED WITH A CLOSED FUEL CYCLE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, C. G.; Ebbinghaus, B.; Sleaford, Brad W.
2010-06-11
This paper examines the attractiveness of materials mixtures containing special nuclear materials (SNM) associated with the various processing steps required for a closed fuel cycle. This paper combines the results from earlier studies that examined the attractiveness of SNM associated with the processing of spent light water reactor (LWR) fuel by various reprocessing schemes and the recycle of plutonium as a mixed oxide (MOX) fuel in LWR with new results for the final, repeated burning of SNM in fast-spectrum reactors: fast reactors and accelerator driven systems (ADS). The results of this paper suggest that all reprocessing products evaluated so farmore » need to be rigorously safeguarded and provided moderate to high levels of physical protection. These studies were performed at the request of the United States Department of Energy (DOE), and are based on the calculation of "attractiveness levels" that has been couched in terms chosen for consistency with those normally used for nuclear materials in DOE nuclear facilities. The methodology and key findings will be presented. Additionally, how these attractiveness levels relate to proliferation resistance (e.g. by increasing impediments to the diversion, theft, or undeclared production of SNM for the purpose of acquiring a nuclear weapon), and how they could be used to help inform policy makers, will be discussed.« less
Ricardo Cisneros; Don Schweizer; Haiganoush Preisler; Deborah H. Bennett; Glenn Shaw; Andrzej Bytnerowicz
2014-01-01
This paper presents particulate matter data collected in the California southern Sierra Nevada Mountains (SNM) during 2002 to 2009 from the Central Valley (elevation 91 m) into the SNM (elevation 2,598 m). Annual average concentrations of particles smaller than 2.5 µm in diameter (PM2.5) for all sites during this study ranged from 3.1 to 22.2 µg...
Nuclear Resonance Fluorescence and Isotopic Mapping of Containers
NASA Astrophysics Data System (ADS)
Johnson, Micah S.; McNabb, Dennis P.
2009-03-01
National security programs have expressed interest in developing systems to isotopically map shipping containers, fuel assemblies, and waste barrels for various materials including special nuclear material (SNM). Current radiographic systems offer little more than an ambiguous density silhouette of a container's contents. In this paper we will present a system being developed at LLNL to isotopically map containers using the nuclear resonance fluorescence (NRF) method. Recent experimental measurements on NRF strengths in SNM are discussed.
Zhang, Peng; Zhang, Jian-Zhong; Wu, Li-Yang; Zhang, Xiao-Dong
2017-02-20
Sacral neuromodulation (SNM) has become an effective method for treating lower urinary tract voiding dysfunction during the past 20 years. Because of the expensive cost, the number of implantable pulse generator (IPG) implantations per year in China is far lower than that in Western developed countries since 2012. This study was to summarize the effects of the appropriate prolonged SNM testing time in improving the implantation rate of a permanent IPG in patients with refractory lower urinary tract symptoms (LUTS) in mainland China. From January 2013 to June 2016, 51 patients with refractory LUTS received SNM therapy. In this study, we compared the conversion rate 2 weeks after the Stage I test and final actual conversion rate. We also observed the complications (such as pain, infection, and electrode displacement) and effectiveness. We tried to improve an appropriate prolonged test time which was favorable for improving the SNM conversion rate while ensuring safety and effectiveness. Among 51 patients receiving SNM therapy, 19 patients (mean age 45.0 ± 16.9 years) had poor Stage I test results, and on an average, the electrode was removed 27.4 ± 9.6 days after the surgery. In one patient, the electrode was removed within 2 weeks; when the remaining 18 patients were questioned 2 weeks after testing, none of the patients wanted to terminate the test, and all the 18 patients desired to prolong the testing time to further observe the treatment effect. The remaining 32 patients (mean age 46.7 ± 15.3 years) received Stage II permanent implantation at 19.6 ± 10.4 days after the surgery. The overall Stage I-II conversion was 62.7% (32/51) in this study. Within 2 weeks after the surgery, only eight patients received Stage II permanent implantation, and the conversion rate was only 15.7% (8/51), which was much lower than the overall conversion rate of 62.7%. Nearly 84.4% (27/32) of the patients received Stage II implantation within 4 weeks. None of the patients had incision infections. In one patient, the entire system was removed 1 month after Stage II implantation due to pain in the implantation site. Appropriate extension of the Stage I testing time of an SNM-barbed electrode could significantly improve the Stage II permanent implantation rate in Chinese refractory LUTS patients; there were no wound infections, and the postoperative complication rate was low. This study recommended that Stage I period of SNM therapy should be 4 weeks according to safety and successful conversion rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, Timothy; Nelson, Roger
The Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) manages defense nuclear material that has been determined to be excess to programmatic needs and declared waste. When these wastes contain plutonium, they almost always meet the definition of defense transuranic (TRU) waste and are thus eligible for disposal at the Waste Isolation Pilot Plant (WIPP). The DOE operates the WIPP in a manner that physical protections for attractiveness level D or higher special nuclear material (SNM) are not the normal operating condition. Therefore, there is currently a requirement to terminate safeguards before disposal of these wastes atmore » the WIPP. Presented are the processes used to terminate safeguards, lessons learned during the termination process, and how these approaches might be useful for future defense TRU waste needing safeguards termination prior to shipment and disposal at the WIPP. Also described is a new criticality control container, which will increase the amount of fissile material that can be loaded per container, and how it will save significant taxpayer dollars. Retrieval, compliant packaging and shipment of retrievably stored legacy TRU waste has dominated disposal operations at WIPP since it began operations 12 years ago. But because most of this legacy waste has successfully been emplaced in WIPP, the TRU waste clean-up focus is turning to newly-generated TRU materials. A major component will be transuranic SNM, currently managed in safeguards-protected vaults around the weapons complex. As DOE and NNSA continue to consolidate and shrink the weapons complex footprint, it is expected that significant quantities of transuranic SNM will be declared surplus to the nation's needs. Safeguards termination of SNM varies due to the wide range of attractiveness level of the potential material that may be directly discarded as waste. To enhance the efficiency of shipping waste with high TRU fissile content to WIPP, DOE designed an over-pack container, similar to the pipe component, called the criticality control over-pack, which will significantly enhance the efficiency of disposal. Hundreds of shipments of transuranic SNM, suitably packaged to meet WIPP waste acceptance criteria and with safeguards terminated have been successfully emplaced at WIPP (primarily from the Rocky Flats site clean-up) since WIPP opened. DOE expects that thousands more may eventually result from SNM consolidation efforts throughout the weapons complex. (authors)« less
Kim, Steven; Heller, James; Iqbal, Zohora; Kant, Rishi; Kim, Eun Jung; Durack, Jeremy; Saeed, Maythem; Do, Loi; Hetts, Steven; Wilson, Mark; Brakeman, Paul; Fissell, William H.; Roy, Shuvo
2015-01-01
Silicon nanopore membranes (SNM) with compact geometry and uniform pore size distribution have demonstrated a remarkable capacity for hemofiltration. These advantages could potentially be used for hemodialysis. Here we present an initial evaluation of the SNM’s mechanical robustness, diffusive clearance, and hemocompatibility in a parallel plate configuration. Mechanical robustness of the SNM was demonstrated by exposing membranes to high flows (200ml/min) and pressures (1,448mmHg). Diffusive clearance was performed in an albumin solution and whole blood with blood and dialysate flow rates of 25ml/min. Hemocompatibility was evaluated using scanning electron microscopy and immunohistochemistry after 4-hours in an extra-corporeal porcine model. The pressure drop across the flow cell was 4.6mmHg at 200ml/min. Mechanical testing showed that SNM could withstand up to 775.7mmHg without fracture. Urea clearance did not show an appreciable decline in blood versus albumin solution. Extra-corporeal studies showed blood was successfully driven via the arterial-venous pressure differential without thrombus formation. Bare silicon showed increased cell adhesion with a 4.1 fold increase and 1.8 fold increase over polyethylene-glycol (PEG)-coated surfaces for tissue plasminogen factor (t-PA) and platelet adhesion (CD-41), respectively. These initial results warrant further design and development of a fully scaled SNM-based parallel plate dialyzer for renal replacement therapy. PMID:26692401
Combining Radiography and Passive Measurements for Radiological Threat Localization in Cargo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.
Detecting shielded special nuclear material (SNM) in a cargo container is a difficult problem, since shielding reduces the amount of radiation escaping the container. Radiography provides information that is complementary to that provided by passive gamma-ray detection systems: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions that may mask a passive radiological signal. Combining these measurements has the potential to improve SNM detection, either through improved sensitivity or by providing a solution to the inverse problem to estimate source properties (strength and location). We present a data-fusion method that uses a radiograph to provide anmore » estimate of the radiation-transport environment for gamma rays from potential sources. This approach makes quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present results for this method for a modeled test case of a cargo container passing through a plastic-scintillator-based radiation portal monitor and a transmission-radiography system. We find that a radiograph-based inversion scheme allows for localization of a low-noise source placed randomly within the test container to within 40 cm, compared to 70 cm for triangulation alone, while strength estimation accuracy is improved by a factor of six. Improvements are seen in regions of both high and low shielding, but are most pronounced in highly shielded regions. The approach proposed here combines transmission and emission data in a manner that has not been explored in the cargo-screening literature, advancing the ability to accurately describe a hidden source based on currently-available instrumentation.« less
RoboCal: An automated nondestructive assay system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staley, H.C.; Hollen, R.M.; Bonner, C.A.
1990-01-01
The manager of a facility handling special nuclear material (SNM) is caught in a squeeze between increased state and federal regulations and tighter funding. RoboCal uses a robot to manipulate canisters containing SNM to lower worker radiation exposure and to provide increased utilization of expensive assay equipment. In addition, it helps with accountability and material tracking. It consists of a hierarchical network of more than a dozen computers and provides a single point of contact for the user to accomplish multiple assays.
Ohnona, Jessica; Michaud, Laure; Balogova, Sona; Paycha, Frédéric; Nataf, Valérie; Chauchat, Paul; Talbot, Jean-Noël; Kerrou, Khaldoun
2013-05-01
18F-Sodium fluoride is a bone tracer with a high signal-to-noise ratio, but its dosimetry is higher than that of 99mTc-labeled phosphonates at the recommended activities. The study's purpose was to determine whether the reduction by half of F-sodium fluoride-injected activity, mimicked by a short-timed reconstruction image, simulating a total dose less than or equal to that of 99mTc-hydroxymethane diphosphonate scintigraphy, had an impact on the accuracy of PET semiquantitative measurements and image quality. Whole-body time-of-flight 18F-sodium fluoride PET/computed tomography (CT) images were acquired prospectively from 40 adult patients for detection of bone metastases. 18F-Sodium fluoride was administered according to the European Association of Nuclear Medicine (EANM) and Society of Nuclear Medicine (SNM) practice guidelines. From the acquired 1 min/bed position list-mode data, 30-s reconstructions were extracted. Measurements of maximum standard uptake value were recorded with a region of interest applied to the same location on the 1-min and 30-s images, which were displayed side by side, and were analyzed using Bland-Altman plots. A masked reading was performed by two senior nuclear medicine physicians who counted the foci of visually increased uptake. Bland-Altman plots showed an excellent agreement between the maximum standard uptake value measurements of the 60- and 30-s images. The paired Wilcoxon test results between the corresponding 60- and 30-s images read by masked readers A and B were not significant (P=0.15 and 0.19, respectively). Reducing acquisition duration by half or injecting half of the activity recommended by the EANM and SNM practice guidelines can lead to 18F-sodium fluoride time-of-flight PET images of diagnostic quality, achieving a radiation dose less than or equal to that of 99mTc-labeled phosphonates.
Evaluation and Testing of the ADVANTG Code on SNM Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaver, Mark W.; Casella, Andrew M.; Wittman, Richard S.
2013-09-24
Pacific Northwest National Laboratory (PNNL) has been tasked with evaluating the effectiveness of ORNL’s new hybrid transport code, ADVANTG, on scenarios of interest to our NA-22 sponsor, specifically of detection of diversion of special nuclear material (SNM). PNNL staff have determined that acquisition and installation of ADVANTG was relatively straightforward for a code in its phase of development, but probably not yet sufficient for mass distribution to the general user. PNNL staff also determined that with little effort, ADVANTG generated weight windows that typically worked for the problems and generated results consistent with MCNP. With slightly greater effort of choosingmore » a finer mesh around detectors or sample reaction tally regions, the figure of merit (FOM) could be further improved in most cases. This does take some limited knowledge of deterministic transport methods. The FOM could also be increased by limiting the energy range for a tally to the energy region of greatest interest. It was then found that an MCNP run with the full energy range for the tally showed improved statistics in the region used for the ADVANTG run. The specific case of interest chosen by the sponsor is the CIPN project from Las Alamos National Laboratory (LANL), which is an active interrogation, non-destructive assay (NDA) technique to quantify the fissile content in a spent fuel assembly and is also sensitive to cases of material diversion. Unfortunately, weight windows for the CIPN problem cannot currently be properly generated with ADVANTG due to inadequate accommodations for source definition. ADVANTG requires that a fixed neutron source be defined within the problem and cannot account for neutron multiplication. As such, it is rendered useless in active interrogation scenarios. It is also interesting to note that this is a difficult problem to solve and that the automated weight windows generator in MCNP actually slowed down the problem. Therefore, PNNL had determined that there is not an effective tool available for speeding up MCNP for problems such as the CIPN scenario. With regard to the Benchmark scenarios, ADVANTG performed very well for most of the difficult, long-running, standard radiation detection scenarios. Specifically, run time speedups were observed for spatially large scenarios, or those having significant shielding or scattering geometries. ADVANTG performed on par with existing codes for moderate sized scenarios, or those with little to moderate shielding, or multiple paths to the detectors. ADVANTG ran slower than MCNP for very simply, spatially small cases with little to no shielding that run very quickly anyway. Lastly, ADVANTG could not solve problems that did not consist of fixed source to detector geometries. For example, it could not solve scenarios with multiple detectors or secondary particles, such as active interrogation, neutron induced gamma, or fission neutrons.« less
NASA Astrophysics Data System (ADS)
Gao, Song; Huang, Hao; Wu, Aimin; Yu, Jieyi; Gao, Jian; Dong, Xinglong; Liu, Chunjing; Cao, Guozhong
2016-10-01
A direct current arc-discharge method was applied to prepare the Sn-M (M=Fe, Al, Ni) bi-alloy nanoparticles. Thermodynamic is introduced to analyze the energy circumstances for the formation of the nanoparticles during the physical condensation process. The electrochemical properties of as-prepared Sn-M alloy nanoparticles are systematically investigated as anodes of Li-ion batteries. Among them, Sn-Fe nanoparticles electrode exhibits high Coulomb efficiency (about 71.2%) in the initial charge/discharge (257.9 mA h g-1/366.6 mA h g-1) and optimal cycle stability (a specific reversible capacity of 240 mA h g-1 maintained after 20 cycles) compared with others. Large differences in the electrochemical behaviors indicate that the chemical composition and microstructure of the nanoparticles determine the lithium-ion storage properties and the long-term cyclic stability during the charge/discharge process.
Silicon nanoporous membranes as a rigorous platform for validation of biomolecular transport models
Feinberg, Benjamin J.; Hsiao, Jeff C.; Park, Jaehyun; Zydney, Andrew L.; Fissell, William H.; Roy, Shuvo
2017-01-01
Microelectromechanical systems (MEMS), a technology that resulted from significant innovation in semiconductor fabrication, have recently been applied to the development of silicon nanopore membranes (SNM). In contrast to membranes fabricated from polymeric materials, SNM exhibit slit-shaped pores, monodisperse pore size, constant surface porosity, zero pore overlap, and sub-micron thickness. This development in membrane fabrication is applied herein for the validation of the XDLVO (extended Derjaguin, Landau, Verwey, and Overbeek) theory of membrane transport within the context of hemofiltration. In this work, the XDLVO model has been derived for the unique slit pore structure of SNM. Beta-2-microglobulin (B2M), a clinically relevant “middle molecular weight” solute in kidney disease, is highlighted in this study as the solute of interest. In order to determine interaction parameters within the XDLVO model for B2M and SNM, goniometric measurements were conducted, yielding a Hamaker constant of 4.61× 10−21 J and an acid-base Gibbs free energy at contact of 41 mJ/m2. The XDLVO model was combined with existing models for membrane sieving, with predictions of the refined model in good agreement with experimental data. Furthermore, the results show a significant difference between the XDLVO model and the simpler steric predictions typically applied in membrane transport. The refined model can be used as a tool to tailor membrane chemistry and maximize sieving or rejection of different biomolecules. PMID:28936029
Poly- Versus Mono-Energetic Dual-Spectrum Non-Intrusive Inspection of Cargo Containers
NASA Astrophysics Data System (ADS)
Martz, Harry E.; Glenn, Steven M.; Smith, Jerel A.; Divin, Charles J.; Azevedo, Stephen G.
2017-07-01
In this paper, based on an invited talk at SORMA (May 2016), we present an overview of x-ray sources, detectors and system configurations for non-intrusive inspection (NII) of cargo containers. Our emphasis is on dual-energy x-ray NII for detecting high-atomic-number (Z ≥ 72) materials such as tungsten shielding and special nuclear materials (SNM). Standard single-energy (MeV and above) x-rays needed to penetrate and image cargo provide little SNM contrast, whereas dual-energy x-ray NII is demonstrated as a way to improve the selectivity of materials with Z<;72 vs. those with Z ≥ 72. For two possible dual-energy x-ray source technologies - polyenergetic dual-energy (PDE) and quasi-monoenergetic x-ray sources (QMXS) - we investigate their trade-offs and future prospects using experimental and simulated results. The reduced scatter and larger separation of low- and high-energy photons provided by QMXS offers improved high-Z material contrast, but practical considerations such as flux and pulse rate need to be solved before making a deployable system. Straight-ray simulations show factor of four increases in contrast for QMXS over PDE scans of tin (Z=50) and iron (Z=26) relative to a uranium plate (Z=92) behind 20 cm of iron simulated cargo.
NASA Astrophysics Data System (ADS)
Clayton, James E.; Bjorkholm, Paul
2006-05-01
The Dual Energy X-ray technique employs two X-ray projection images of an object with X-ray energy spectra at a low X-ray energy and a high X-ray energy. The two energies are both high enough to penetrate all cargoes. The endpoint energies for low and high will be approximately 5-6 MeV and 8-9.5 MeV respectively. These energies are chosen such that pair production is the dominant energy loss mechanism for the high energy mode. By defining the ratio of the transmitted X-ray photon R = T high/T low it can be shown that there is a difference in the ratio that will permit the detection of materials that are significantly higher in atomic number than the low to mid atomic numbered elements that normally appear in the stream of commerce. This difference can be used to assist in the automatic detection of high atomic numbered materials. These materials might be a WMD or dirty bomb. When coupled with detectors that can observe the delayed signature of photon induced fission a confirmation of a WMD may be made. The use of the delayed photons and neutrons from Photofission can confirm the presence of Special Nuclear Materials (SNM). The energy required to induce fission in SNM by a photon is approximately 6 MeV with the maximum fission production rate from X-ray photons in the energy range of 12-15 MeV.
Combining Radiography and Passive Measurements for Radiological Threat Detection in Cargo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; White, Timothy A.; Jarman, Kenneth D.
Abstract Radiography is widely understood to provide information complimentary to passive detection: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions which may mask a passive radiological signal. We present a method for combining radiographic and passive data which uses the radiograph to provide an estimate of scatter and attenuation for possible sources. This approach allows quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present first results for this method for a simple modeled test case of a cargo container drivingmore » through a PVT portal. With this inversion approach, we address criteria for an integrated passive and radiographic screening system and how detection of SNM threats might be improved in such a system.« less
Wang, Junpeng; Chen, Yang; Chen, Jiawei; Zhang, Guihao; Wu, Peng
2017-09-08
Bladder pain syndrome/interstitial cystitis (BPS/IC) is a common debilitating disease and there has not been consistently effective treatment. We aimed to evaluate all available literature regarding the efficacy and safety of sacral neuromodulation (SNM) for refractory BPS/IC. A comprehensive search of Pubmed, Web of Science and Cochrane Library through May 2016 was conducted. A total of 17 studies enrolling 583 patients were identified. Pooled analyses demonstrated that SNM was associated with great reduction in pelvic pain (weighted mean difference [WMD] -3.99; 95% confidence interval [CI] -5.22 to -2.76; p < 0.00001), Interstitial Cystitis Problem and Symptom Index scores (WMD -6.34; 95% CI -9.57 to -3.10; p = 0.0001; and WMD -7.17; 95% CI -9.90 to -4.45; p < 0.00001, respectively), daytime frequency (WMD -7.45; 95% CI -9.68 to -5.22; p < 0.00001), nocturia (WMD -3.01; 95% CI -3.56 to -2.45; p < 0.00001), voids per 24 hours (WMD -9.32; 95% CI -10.90 to -7.74; p < 0.00001) and urgency (WMD -1.08; 95% CI -1.79 to -0.37; p = 0.003) as well as significant improvement in average voided volume (WMD 95.16 ml; 95% CI 63.64 to 126.69; p < 0.0001). The pooled treatment success rate was 84% (95% CI 76% to 91%). SNM-related adverse events were minimal. Current evidence indicates that SNM might be effective and safe for treating refractory BPS/IC.
Blok, Bertil; Van Kerrebroeck, Philip; de Wachter, Stefan; Ruffion, Alain; Van der Aa, Frank; Jairam, Ranjana; Perrouin-Verbe, Marie; Elneil, Sohier
2018-02-01
The RELAX-OAB study is designed to confirm the safety, efficacy, and technical performance of the Axonics r-SNM System, a miniaturized, rechargeable SNM system approved in Europe and Canada for the treatment of bladder and bowel dysfunction. The purpose of this article is to describe study subjects' ability to charge the rechargeable neurostimulator and to document their neurostimulator program settings and recharge interval over time. Fifty-one OAB patients were implanted in a single-stage procedure. These results represent the 3-month charging experience for 48 subjects who completed the 3-month follow-up. Recharge intervals were estimated using therapy stimulation settings and subject experience was evaluated using questionnaires. Forty-seven of forty-eight (98%) subjects were able to successfully charge their device prior to follow-up within 1-month post-implant. At 3-month post-implant, 98% of subjects were able to charge prior to their follow-up visit. Average stimulation amplitude across all subjects was 1.8 mA (±1.1 mA). A total of 69% of subjects had ≥14-day recharge intervals (time between charging) and 98% of subjects had ≥7-day recharge interval. No charging related adverse events occurred. Study subjects were able to charge the Axonics r-SNM System and stimulation settings provided 2 weeks of therapy between recharging for most subjects. Subject satisfaction indicates that subjects are satisfied with rechargeable SNM therapy. © 2018 The Authors. Neurourology and Urodynamics Published by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Smith, Ross A.; Fleischman, Aaron J.; Fissell, William H.; Zorman, Christian A.; Roy, Shuvo
2011-04-01
We report an automated system for measuring the hydraulic permeability of nanoporous membranes in a tangential-flow configuration. The system was designed and built specifically for micromachined silicon nanoporous membranes (SNM) with monodisperse slit-shaped pores. These novel membranes are under development for water filtration, artificial organ and drug delivery applications. The filtration cell permits non-destructive testing of the membrane over many remove-modify-replace testing cycles, allowing for direct experiments into the effects of surface modifications on such membranes. The experimental apparatus was validated using microfluidic tubing with circular cross sections that provided similar fluidic resistances to SNM. Further validation was performed with SNM chips for which the pore dimensions were known from scanning electron microscopy measurements. The system was then used to measure the hydraulic permeability of nanoporous membranes before and after surface modification. The system yields measurements with low variance and excellent agreement with predicted values, providing a platform for determining pore sizes in micro/nanofluidic systems with tight pore size distributions to a higher degree of precision than can be achieved with traditional techniques.
NASA Astrophysics Data System (ADS)
Sibczynski, P.; Kownacki, J.; Moszyński, M.; Iwanowska-Hanke, J.; Syntfeld-Każuch, A.; Gójska, A.; Gierlik, M.; Kaźmierczak, Ł.; Jakubowska, E.; Kędzierski, G.; Kujawiński, Ł.; Wojnarowicz, J.; Carrel, F.; Ledieu, M.; Lainé, F.
2015-09-01
In the present study ⌀ 5''× 3'' and ⌀ 2''× 2'' EJ-313 liquid fluorocarbon as well as ⌀ 2'' × 3'' BaF2 scintillators were exposed to neutrons from a 252Cf neutron source and a Sodern Genie 16GT deuterium-tritium (D+T) neutron generator. The scintillators responses to β- particles with maximum endpoint energy of 10.4 MeV from the n+19F reactions were studied. Response of a ⌀ 5'' × 3'' BC-408 plastic scintillator was also studied as a reference. The β- particles are the products of interaction of fast neutrons with 19F which is a component of the EJ-313 and BaF2 scintillators. The method of fast neutron detection via fluorine activation is already known as Threshold Activation Detection (TAD) and was proposed for photofission prompt neutron detection from fissionable and Special Nuclear Materials (SNM) in the field of Homeland Security and Border Monitoring. Measurements of the number of counts between 6.0 and 10.5 MeV with a 252Cf source showed that the relative neutron detection efficiency ratio, defined as epsilonBaF2 / epsilonEJ-313-5'', is 32.0% ± 2.3% and 44.6% ± 3.4% for front-on and side-on orientation of the BaF2, respectively. Moreover, the ⌀ 5'' EJ-313 and side-on oriented BaF2 were also exposed to neutrons from the D+T neutron generator, and the relative efficiency epsilonBaF2 / epsilonEJ-313-5'' was estimated to be 39.3%. Measurements of prompt photofission neutrons with the BaF2 detector by means of data acquisition after irradiation (out-of-beam) of nuclear material and between the beam pulses (beam-off) techniques were also conducted on the 9 MeV LINAC of the SAPHIR facility.
Paired N and O isotopic analysis of nitrate and nitrite in the Arabian Sea oxygen deficient zone
NASA Astrophysics Data System (ADS)
Martin, T. S.; Casciotti, K. L.
2017-03-01
The Arabian Sea is home to one of the three main oceanic oxygen deficient zones (ODZs). We present paired nitrogen (N) and oxygen (O) isotope measurements of nitrate (NO3-) and nitrite (NO2-) from the central Arabian Sea in order to understand the effects of N biogeochemistry on the distribution of these species in the low oxygen waters. Within the ODZ, NO2- accumulated in a secondary NO2- maximum (SNM), though the shape and magnitude of the SNM, along with the isotopic composition of NO3- and NO2-, were highly dependent on the location within the ODZ. We also explored water mass mixing within the Arabian Sea as an explanatory factor in the distribution of NO2- in the SNM. The intrusion of Persian Gulf Water at depth may influence the shape of the NO2- peak by introducing small amounts of dissolved oxygen (O2), favoring NO2- oxidation. There was also evidence that vertical mixing may play a role in shaping the top of the SNM peak. Finally, we present evidence for NO2- oxidation and NO2- reduction co-occurring within the ODZ, as has been previously suggested in the Arabian Sea, as well as in other ODZs. The decoupling of the N and O isotopes of NO3-, deviating from the expected 1:1 ratio for dissimilatory NO3- reduction, indicates that NO2- oxidation has a significant influence on the isotopic composition of NO3-. Additionally, the N isotopes of NO2- were generally fit well by Rayleigh curves for NO2- oxidation. However, the removal of dissolved inorganic nitrogen (DIN) within the domain reflects the importance of NO2- reduction to N2.
Bertapelle, Maria Paola; Vottero, Mario; Popolo, Giulio Del; Mencarini, Marco; Ostardo, Edoardo; Spinelli, Michele; Giannantoni, Antonella; D'Ausilio, Anna
2015-08-01
To assess the relative cost-effectiveness of two therapeutic strategies: one starting with sacral neuromodulation (SNM) versus one starting with Botulinum toxin A (BTX-A) for the management of refractory incontinent idiopathic overactive bladder (OAB) patients, from the perspective of the Italian National Health Service (INHS). Direct medical costs (
High efficiency proportional neutron detector with solid liner internal structures
Kisner, Roger Allen; Holcomb, David Eugene; Brown, Gilbert M.
2014-08-05
A tube-style neutron detector, a panel-style neutron detector incorporating a plurality of tube-style neutron detectors, and a panel-style neutron detector including a plurality of anode wires are provided. A plurality of channels is provided in a neutron detector such that each channel has an inner surface of a coating layer including a neutron-absorbing material. A wire anode is provided at end of each channel so that electrons generated by a charged daughter particle generated by a neutron are collected to detect a neutron-matter interaction. Moderator units can be incorporated into a neutron detector to provide improved detection efficiencies and/or to determine neutron energy spectrum. Gas-based proportional response from the neutron detectors can be employed for special nuclear material (SNM) detection. This neutron detector can provide similar performance to .sup.3He-based detectors without requiring .sup.3He and without containing toxic, flammable, or high-pressure materials.
Direct measurement of 235U in spent fuel rods with Gamma-ray mirrors
NASA Astrophysics Data System (ADS)
Ruz, J.; Brejnholt, N. F.; Alameda, J. B.; Decker, T. A.; Descalle, M. A.; Fernandez-Perea, M.; Hill, R. M.; Kisner, R. A.; Melin, A. M.; Patton, B. W.; Soufli, R.; Ziock, K.; Pivovaroff, M. J.
2015-03-01
Direct measurement of plutonium and uranium X-rays and gamma-rays is a highly desirable non-destructive analysis method for the use in reprocessing fuel environments. The high background and intense radiation from spent fuel make direct measurements difficult to implement since the relatively low activity of uranium and plutonium is masked by the high activity from fission products. To overcome this problem, we make use of a grazing incidence optic to selectively reflect Kα and Kβ fluorescence of Special Nuclear Materials (SNM) into a high-purity position-sensitive germanium detector and obtain their relative ratios.
Diffusive Silicon Nanopore Membranes for Hemodialysis Applications
Kim, Steven; Feinberg, Benjamin; Kant, Rishi; Chui, Benjamin; Goldman, Ken; Park, Jaehyun; Moses, Willieford; Blaha, Charles; Iqbal, Zohora; Chow, Clarence; Wright, Nathan; Fissell, William H.; Zydney, Andrew; Roy, Shuvo
2016-01-01
Hemodialysis using hollow-fiber membranes provides life-sustaining treatment for nearly 2 million patients worldwide with end stage renal disease (ESRD). However, patients on hemodialysis have worse long-term outcomes compared to kidney transplant or other chronic illnesses. Additionally, the underlying membrane technology of polymer hollow-fiber membranes has not fundamentally changed in over four decades. Therefore, we have proposed a fundamentally different approach using microelectromechanical systems (MEMS) fabrication techniques to create thin-flat sheets of silicon-based membranes for implantable or portable hemodialysis applications. The silicon nanopore membranes (SNM) have biomimetic slit-pore geometry and uniform pores size distribution that allow for exceptional permeability and selectivity. A quantitative diffusion model identified structural limits to diffusive solute transport and motivated a new microfabrication technique to create SNM with enhanced diffusive transport. We performed in vitro testing and extracorporeal testing in pigs on prototype membranes with an effective surface area of 2.52 cm2 and 2.02 cm2, respectively. The diffusive clearance was a two-fold improvement in with the new microfabrication technique and was consistent with our mathematical model. These results establish the feasibility of using SNM for hemodialysis applications with additional scale-up. PMID:27438878
Do "clicker" educational sessions enhance the effectiveness of a social norms marketing campaign?
Killos, Lydia F; Hancock, Linda C; Wattenmaker McGann, Amanda; Keller, Adrienne E
2010-01-01
social norms campaigns are a cost-effective way to reduce high-risk drinking on college campuses. This study compares effectiveness of a "standard" social norms media (SNM) campaign for those with and without exposure to additional educational sessions using audience response technology ("clickers"). American College Health Association's National College Health Assessment questions are used to evaluate actual and perceived use. Additional survey questions assess individual exposure to the interventions. the authors find "clicker" technology to be more effective than social norms poster media alone in reducing misperceptions of normative alcohol use for those students who attended clicker sessions. poster SNM campaigns may be most effective when supported by group "clicker" heath-related sessions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, C. G.; Jarvinen, G. D.; Wallace, R. K.
2008-10-01
This paper summarizes the results of an extension to an earlier study [ ] that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) associated with the PUREX, UREX+, and COEX reprocessing schemes. This study focuses on the materials associated with the UREX, COEX, THOREX, and PYROX reprocessing schemes. This study also examines what is required to render plutonium as “unattractive.” Furthermore, combining the results of this study with those from the earlier study permits a comparison of the uranium and thorium based fuel cycles on the basis of the attractiveness of the SNM associated with each fuelmore » cycle. Both studies were performed at the request of the United States Department of Energy (DOE), and are based on the calculation of “attractiveness levels” that has been couched in terms chosen for consistency with those normally used for nuclear materials in DOE nuclear facilities [ ]. The methodology and key findings will be presented. Additionally, how these attractiveness levels relate to proliferation resistance (e.g. by increasing impediments to the diversion, theft, undeclared production of SNM for the purpose of acquiring a nuclear weapon), and how they could be used to help inform policy makers, will be discussed.« less
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity measurements with 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald; Detwiler, Ryan
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as ‘‘ship effect ’’) and to the complicated nature of the neutron scattering in that environment. A prototype neutron detector was built using 10B as the converter in a special form factor called ‘‘straws’’ that would address the above problems by looking into the details of multiplicity distributions of neutrons originatingmore » from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylenemoderator. In the following year, we developed the field-programmable gate array and associated DAQ software. This SDRD effort successfully produced a prototype NMC with*33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; ...
2015-01-27
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Numerical convergence and validation of the DIMP inverse particle transport model
Nelson, Noel; Azmy, Yousry
2017-09-01
The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector re-sponses (using the adjoint transport solution) with measured responses. DIMP performs well with for-ward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to themore » correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search vol-ume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.« less
A Delayed Neutron Counting System for the Analysis of Special Nuclear Materials
NASA Astrophysics Data System (ADS)
Sellers, Madison Theresa
Nuclear forensic analysis is a modem science that uses numerous analytical techniques to identify and attribute nuclear materials in the event of a nuclear explosion, radiological terrorist attack or the interception of illicit nuclear material smuggling. The Canadian Department of National Defence has participated in recent international exercises that have highlighted the Nation's requirement to develop nuclear forensics expertise, protocol and capabilities, specifically pertaining to the analysis of special nuclear materials (SNM). A delayed neutron counting (DNC) system has been designed and established at the Royal Military College of Canada (RMC) to enhance the Government's SNM analysis capabilities. This analytical technique complements those already at RMC by providing a rapid and non-destructive method for the analysis of the fissile isotopes of both uranium (U) and plutonium (Pu). The SLOWPOKE-2 reactor at RMC produces a predominately thermal neutron flux. These neutrons induce fission in the SNM isotopes 233U, 235U and 239Pu releasing prompt fast neutrons, energy and radioactive fission fragments. Some of these fission fragments undergo beta - decay and subsequently emit neutrons, which can be recorded by an array of sensitive 3He detectors. The significant time period between the fission process and the release of these neutrons results in their identification as 'delayed neutrons'. The recorded neutron spectrum varies with time and the count rate curve is unique to each fissile isotope. In-house software, developed by this project, can analyze this delayed neutron curve and provides the fissile mass in the sample. Extensive characterization of the DNC system has been performed with natural U samples with 235 U content ranging from 2--7 microg. The system efficiency and dead time behaviour determined by the natural uranium sample analyses were validated by depleted uranium samples with similar quantities of 235 U resulting in a typical relative error of 3.6%. The system has accurately determined 235U content over three orders of magnitude with 235U amounts as low as 10 ng. The results have also been proven to be independent of small variations in total analyte volume and geometry, indicating that it is an ideal technique for the analysis of samples containing SNM in a variety of different matrices. The Analytical Sciences Group at RMC plans to continue DNC system development to include 233U and 239pu analysis and mixtures of SNM isotopes. Keywords: delayed neutron counting, special nuclear materials, nuclear forensics.
Dual-Particle Imaging System with Neutron Spectroscopy for Safeguard Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamel, Michael C.; Weber, Thomas M.
2017-11-01
A dual-particle imager (DPI) has been designed that is capable of detecting gamma-ray and neutron signatures from shielded SNM. The system combines liquid organic and NaI(Tl) scintillators to form a combined Compton and neutron scatter camera. Effective image reconstruction of detected particles is a crucial component for maximizing the performance of the system; however, a key deficiency exists in the widely used iterative list-mode maximum-likelihood estimation-maximization (MLEM) image reconstruction technique. For MLEM a stopping condition is required to achieve a good quality solution but these conditions fail to achieve maximum image quality. Stochastic origin ensembles (SOE) imaging is a goodmore » candidate to address this problem as it uses Markov chain Monte Carlo to reach a stochastic steady-state solution. The application of SOE to the DPI is presented in this work.« less
Feasibility study for early removal of HEU from CPP-651-Phase II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, C.V.; Henry, R.; Milligan, C.
1997-09-01
A two-phase feasibility study was initiated in late 1996 to identify a way to expedite the removal of SNM from the CPP-651 vault. The first phase of this study provided preliminary information that appeared promising, but needed additional detailed planning and evaluate to validate the concepts and conclusions. The focus of Phase 2 was to provide the validation via resource-loaded schedules and more detailed cost estimates. Section 1 describes the purpose and objectives of the Phase 2 tasks and the programmatic drivers that influence related CPP-651 high-enriched uranium (HEU) management issues. Section 2 identifies the evaluation criteria and methodology andmore » the transfer issues and barriers preventing shipment. Section 3 provides site-specific background information for the CPP-651 facility and the Idaho National Engineering and Environmental Laboratory (INEEL) and describes the development of the basic material removal schedule, the proposed base case plan for removal of SNM, and the proposed HEU material management/shipping issues and strategies. Section 4 identifies the proposed options for accelerated removal of SNM and how they were evaluated via detailed scheduling, resource histograms, and cost analysis. Section 5 summarizes principal tasks for implementing this plan and other related HEU CPP-651 management issues that require continued planning efforts to assure successful implementation of this proposed early removal strategy.« less
Report on Concepts & Approaches for SSBD for eCHEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, Chantell Lynne-Marie
The verification of special nuclear material (SNM) in spent fuel pyroprocessing is an important safeguards challenge. The detection of spontaneous fission (SF) neutrons from curium is an accepted, non-destructive technique that has been applied to verify special nuclear material (SNM) content in used fuel and other materials in the fuel cycle. The nuclear material accounting (NMA) technique at the Korea Atomic Energy Research Institute’s Reference Engineering-scale Pyroprocessing Facility (REPF) is based on the Cm balance technique. Several publications have demonstrated the safeguards benefit from using process monitoring (PM) on nuclear facilities as a complementary measure to NMA. More recently, thismore » concept was expanded and preliminarily demonstrated for pyroprocessing. The concept of Signature Based Safeguards (SBS) is part of this expansion, and is built around the interpretation of input from various sensors in a declared facility coupled with complementary NMA methods to increase confidence and lower standard error inventory differences (SEID). The SBS methodology was conceptually developed and relies on near real time analysis of process monitoring data to detect material diversion complemented by robust containment and surveillance (C/S) measures. This work demonstrates one example of how the SBS framework can be used in the electrorefiner. In this SBS application, a combination of cyclic voltammetry (CV) and neutron counting is applied to track and monitor Pu mass balance. The main purpose of this experiment is to determine if meaningful information can be gained from CV measurements with regard to the Mg/Gd ratio. This data will be coupled with ICP-MS to verify Gd concentrations and analyzed for statistical significance. It is expected the CV data will register a significant change under the off-normal operating conditions. Knowing how to identify and interpret those changes may help inform how to target more traditional neutron counting methods, which could support a more efficient safeguards system. The experimental results will be compared with theoretical calculations and the ERAD simulations.« less
Modeling the Production of Beta-Delayed Gamma Rays for the Detection of Special Nuclear Materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, J M; Pruet, J A; Brown, D A
2005-02-14
The objective of this LDRD project was to develop one or more models for the production of {beta}-delayed {gamma} rays following neutron-induced fission of a special nuclear material (SNM) and to define a standardized formatting scheme which will allow them to be incorporated into some of the modern, general-purpose Monte Carlo transport codes currently being used to simulate inspection techniques proposed for detecting fissionable material hidden in sea-going cargo containers. In this report, we will describe a Monte Carlo model for {beta}-delayed {gamma}-ray emission following the fission of SNM that can accommodate arbitrary time-dependent fission rates and photon collection histories.more » The model involves direct sampling of the independent fission yield distributions of the system, the branching ratios for decay of individual fission products and spectral distributions representing photon emission from each fission product and for each decay mode. While computationally intensive, it will be shown that this model can provide reasonably detailed estimates of the spectra that would be recorded by an arbitrary spectrometer and may prove quite useful in assessing the quality of evaluated data libraries and identifying gaps in the libraries. The accuracy of the model will be illustrated by comparing calculated and experimental spectra from the decay of short-lived fission products following the reactions {sup 235}U(n{sub th}, f) and {sup 239}Pu(n{sub th}, f). For general-purpose transport calculations, where a detailed consideration of the large number of individual {gamma}-ray transitions in a spectrum may not be necessary, it will be shown that a simple parameterization of the {gamma}-ray source function can be defined which provides high-quality average spectral distributions that should suffice for calculations describing photons being transported through thick attenuating media. Finally, a proposal for ENDF-compatible formats that describe each of the models and allow for their straightforward use in Monte Carlo codes will be presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, Helen M. O'D.; Joyce, Malcolm J.; Jones, Ashley
2015-07-01
It is well documented that {sup 238}U decays by spontaneous fission, and that it is the main component of most nuclear fuels. As nuclear fuels are largely classed as Special Nuclear Material (SNM), they have to be fully accounted for by owners and processing facilities. One possible method for verifying declared amounts of SNM is to count the spontaneous neutrons produced from {sup 238}U. Using four EJ-309 liquid scintillation detectors and a mixed field analyser, spontaneous neutrons from 16.4 g of depleted uranium (0.3% enrichment) have been assayed. The assay method shows promising results and this proof of principle willmore » be researched further in order for it to be applied in an industrial setting. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerr, P. L.; Decman, D.; Prasad, M.
An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements inmore » a way the does not reveal sensitive information. In full IB mode, only the pass/fail result is displayed as a “Mass <= Threshold Amount” or “Mass >= Threshold Amount” as shown in Figure 4. This can easily be adapted to a red/green “lights” display similar to the Detective IB system for Pu isotopics as shown in Figure 6. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.« less
Clinal variation at phenology-related genes in spruce: parallel evolution in FTL2 and Gigantea?
Chen, Jun; Tsuda, Yoshiaki; Stocks, Michael; Källman, Thomas; Xu, Nannan; Kärkkäinen, Katri; Huotari, Tea; Semerikov, Vladimir L; Vendramin, Giovanni G; Lascoux, Martin
2014-07-01
Parallel clines in different species, or in different geographical regions of the same species, are an important source of information on the genetic basis of local adaptation. We recently detected latitudinal clines in SNPs frequencies and gene expression of candidate genes for growth cessation in Scandinavian populations of Norway spruce (Picea abies). Here we test whether the same clines are also present in Siberian spruce (P. obovata), a close relative of Norway spruce with a different Quaternary history. We sequenced nine candidate genes and 27 control loci and genotyped 14 SSR loci in six populations of P. obovata located along the Yenisei river from latitude 56°N to latitude 67°N. In contrast to Scandinavian Norway spruce that both departs from the standard neutral model (SNM) and shows a clear population structure, Siberian spruce populations along the Yenisei do not depart from the SNM and are genetically unstructured. Nonetheless, as in Norway spruce, growth cessation is significantly clinal. Polymorphisms in photoperiodic (FTL2) and circadian clock (Gigantea, GI, PRR3) genes also show significant clinal variation and/or evidence of local selection. In GI, one of the variants is the same as in Norway spruce. Finally, a strong cline in gene expression is observed for FTL2, but not for GI. These results, together with recent physiological studies, confirm the key role played by FTL2 and circadian clock genes in the control of growth cessation in spruce species and suggest the presence of parallel adaptation in these two species. Copyright © 2014 by the Genetics Society of America.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, C. G.; Ebbinghaus, Bartley B.; Collins, Brian A.
2012-08-29
We must anticipate that the day is approaching when details of nuclear weapons design and fabrication will become common knowledge. On that day we must be particularly certain that all special nuclear materials (SNM) are adequately accounted for and protected and that we have a clear understanding of the utility of nuclear materials to potential adversaries. To this end, this paper examines the attractiveness of materials mixtures containing SNM and alternate nuclear materials associated with the plutonium-uranium reduction extraction (Purex), uranium extraction (UREX), coextraction (COEX), thorium extraction (THOREX), and PYROX (an electrochemical refining method) reprocessing schemes. This paper provides amore » set of figures of merit for evaluating material attractiveness that covers a broad range of proliferant state and subnational group capabilities. The primary conclusion of this paper is that all fissile material must be rigorously safeguarded to detect diversion by a state and must be provided the highest levels of physical protection to prevent theft by subnational groups; no 'silver bullet' fuel cycle has been found that will permit the relaxation of current international safeguards or national physical security protection levels. The work reported herein has been performed at the request of the U.S. Department of Energy (DOE) and is based on the calculation of 'attractiveness levels' that are expressed in terms consistent with, but normally reserved for, the nuclear materials in DOE nuclear facilities. The methodology and findings are presented. Additionally, how these attractiveness levels relate to proliferation resistance and physical security is discussed.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-13
... safety, chemical process safety, fire safety, emergency management, environmental protection... the transportation of SNM of low strategic significance, human factors engineering, and electrical...
Comparison of Fast Neutron Detector Technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stange, Sy; Mckigney, Edward Allen
2015-02-09
This report documents the work performed for the Department of Homeland Security Domestic Nuclear Detection O ce as the project Fast Neutron Detection Evaluation under contract HSHQDC-14-X-00022. This study was performed as a follow-on to the project Study of Fast Neutron Signatures and Measurement Techniques for SNM Detection - DNDO CFP11-100 STA-01. That work compared various detector technologies in a portal monitor con guration, focusing on a comparison between a number of fast neutron detection techniques and two standard thermal neutron detection technologies. The conclusions of the earlier work are contained in the report Comparison of Fast Neutron Detector Technologies.more » This work is designed to address questions raised about assumptions underlying the models built for the earlier project. To that end, liquid scintillators of two di erent sizes{ one a commercial, o -the-shelf (COTS) model of standard dimensions and the other a large, planer module{were characterized at Los Alamos National Laboratory. The results of those measurements were combined with the results of the earlier models to gain a more complete picture of the performance of liquid scintillator as a portal monitor technology.« less
[Control of vertical dimension in the Root technique. Part 2. Class II].
Labarrère, H
2005-03-01
Hyperdivergent, or high angle, Class II skeletal malocclusions require a reduction in that angle so that an optimal counter-reduction of the mandible can be obtained. Four of these types of cases are analyzed here to show: in the first, treated without extractions, the limitations of this approach: the poor esthetic result derives from the incomplete retraction of incisors because of the occlusal deficits further correction would have incurred; in the second, treated with extractions of upper and lower first bicuspids, that a reduction of the angles SNM from 45 degrees to 40 degrees, FMA from 27 degrees to 24 degrees and ANB from 90 to 40 was obtained; in the third case, treated with extractions of the upper first bicuspids and the lower second bicuspids, that a counter-rotation of the mandible was required in order not to aggravate the esthetic problem while the dental deformity was being corrected. Angle SNM was reduced from 30 degrees to 25 degrees, FMA from 26 degrees to 20 degrees, and ANB from 7 degrees to 2 degrees; and, in the fourth case, where an atypical extraction scheme was elected, that an effective orthodonticsurgical alternative is available. Thanks to an anchorage conception specifically designed for this case by T. Root allowing for extraction of upper first molars, angle SNM was reduced from 38 degrees to 35 degrees, FMA was changed from 28 degrees to 23 degrees, and ANB dropped from 10 degrees to 3.5 degrees.
d'Errico, F; Chierici, A; Gattas-Sethi, M; Philippe, S; Goldston, R; Glaser, A
2018-04-25
In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers 'interrogated' with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.
NASA Astrophysics Data System (ADS)
Langeveld, Willem G. J.
The most widely used technology for the non-intrusive active inspection of cargo containers and trucks is x-ray radiography at high energies (4-9 MeV). Technologies such as dual-energy imaging, spectroscopy, and statistical waveform analysis can be used to estimate the effective atomic number (Zeff) of the cargo from the x-ray transmission data, because the mass attenuation coefficient depends on energy as well as atomic number Z. The estimated effective atomic number, Zeff, of the cargo then leads to improved detection capability of contraband and threats, including special nuclear materials (SNM) and shielding. In this context, the exact meaning of effective atomic number (for mixtures and compounds) is generally not well-defined. Physics-based parameterizations of the mass attenuation coefficient have been given in the past, but usually for a limited low-energy range. Definitions of Zeff have been based, in part, on such parameterizations. Here, we give an improved parameterization at low energies (20-1000 keV) which leads to a well-defined Zeff. We then extend this parameterization up to energies relevant for cargo inspection (10 MeV), and examine what happens to the Zeff definition at these higher energies.
Fast Neutron Detection Using Pixelated CdZnTe Spectrometers
NASA Astrophysics Data System (ADS)
Streicher, Michael; Goodman, David; Zhu, Yuefeng; Brown, Steven; Kiff, Scott; He, Zhong
2017-07-01
Fast neutrons are an important signature of special nuclear materials (SNMs). They have a low natural background rate and readily penetrate high atomic number materials that easily shield gamma-ray signatures. Therefore, they provide a complementary signal to gamma rays for detecting shielded SNM. Scattering kinematics dictate that a large nucleus (such as Cd or Te) will recoil with small kinetic energy after an elastic collision with a fast neutron. Charge carrier recombination and quenching further reduce the recorded energy deposited. Thus, the energy threshold of CdZnTe detectors must be very low in order to sense the small signals from these recoils. In this paper, the threshold was reduced to less than 5 keVee to demonstrate that the 5.9-keV X-ray line from 55Fe could be separated from electronic noise. Elastic scattering neutron interactions were observed as small energy depositions (less than 20 keVee) using digitally sampled pulse waveforms from pixelated CdZnTe detectors. Characteristic gamma-ray lines from inelastic neutron scattering were also observed.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-29
... Accounting Regulations and Proposed Guidance for Fuel Cycle Facility Material Control and Accounting Plans... material control and accounting (MC&A) of special nuclear material (SNM) and the proposed guidance...
Nanomanufacturing-related programs at NSF
NASA Astrophysics Data System (ADS)
Cooper, Khershed P.
2015-08-01
The National Science Foundation is meeting the challenge of transitioning lab-scale nanoscience and technology to commercial-scale through several nanomanufacturing-related research programs. The goal of the core Nanomanufacturing (NM) and the inter-disciplinary Scalable Nanomanufacturing (SNM) programs is to meet the barriers to manufacturability at the nano-scale by developing the fundamental principles for the manufacture of nanomaterials, nanostructures, nanodevices, and engineered nanosystems. These programs address issues such as scalability, reliability, quality, performance, yield, metrics, and cost, among others. The NM and SNM programs seek nano-scale manufacturing ideas that are transformative, that will be widely applicable and that will have far-reaching technological and societal impacts. It is envisioned that the results from these basic research programs will provide the knowledge base for larger programs such as the manufacturing Nanotechnology Science and Engineering Centers (NSECs) and the Nanosystems Engineering Research Centers (NERCs). Besides brief descriptions of these different programs, this paper will include discussions on novel
Comparative study of three-nucleon potentials in nuclear matter
NASA Astrophysics Data System (ADS)
Lovato, Alessandro; Benhar, Omar; Fantoni, Stefano; Schmidt, Kevin E.
2012-02-01
A new generation of local three-body potentials providing an excellent description of the properties of light nuclei, as well as of the neutron-deuteron doublet scattering length, has been recently derived. We have performed a comparative analysis of the equations of state of both pure neutron matter (PNM) and symmetric nuclear matter (SNM) at zero temperature obtained using these models of three-nucleon forces. In particular, we have carried out both variational and auxiliary field diffusion Monte Carlo calculations of the equation of state of PNM, while in the case of SNM we have only the variational approach has been considered. None of the considered potentials simultaneously explains the empirical equilibrium density and binding energy of symmetric nuclear matter. However, two of them provide reasonable values of the saturation density. The ambiguity concerning the treatment of the contact term of the chiral inspired potentials is discussed.
Digital Signal Processing Methods for Safety Systems Employed in Nuclear Power Industry
NASA Astrophysics Data System (ADS)
Popescu, George
Some of the major safety concerns in the nuclear power industry focus on the readiness of nuclear power plant safety systems to respond to an abnormal event, the security of special nuclear materials in used nuclear fuels, and the need for physical security to protect personnel and reactor safety systems from an act of terror. Routine maintenance and tests of all nuclear reactor safety systems are performed on a regular basis to confirm the ability of these systems to operate as expected. However, these tests do not determine the reliability of these safety systems and whether the systems will perform for the duration of an accident and whether they will perform their tasks without failure after being engaged. This research has investigated the progression of spindle asynchronous error motion determined from spindle accelerations to predict bearings failure onset. This method could be applied to coolant pumps that are essential components of emergency core cooling systems at all nuclear power plants. Recent security upgrades mandated by the Nuclear Regulatory Commission and the Department of Homeland Security have resulted in implementation of multiple physical security barriers around all of the commercial and research nuclear reactors in the United States. A second part of this research attempts to address an increased concern about illegal trafficking of Special Nuclear Materials (SNM). This research describes a multi element scintillation detector system designed for non - invasive (passive) gamma ray surveillance for concealed SNM that may be within an area or sealed in a package, vehicle or shipping container. Detection capabilities of the system were greatly enhanced through digital signal processing, which allows the combination of two very powerful techniques: 1) Compton Suppression (CS) and 2) Pulse Shape Discrimination (PSD) with less reliance on complicated analog instrumentation.
LaBr3γ-ray spectrometer for detecting 10B in debris of melted nuclear fuel
NASA Astrophysics Data System (ADS)
Koizumi, Mitsuo; Tsuchiya, Harufumi; Kitatani, Fumito; Harada, Hideo; Heyse, Jan; Kopecky, Stefan; Mondelaers, Willy; Paradela, Carlos; Schillebeeckx, Peter
2016-11-01
Neutron resonance densitometry has been proposed as a nondestructive analytical method for quantifying special nuclear material (SNM) in the rock- and particle-like debris that is to be removed from the Fukushima Daiichi nuclear power plant. The method is based on neutron resonance transmission analysis (NRTA) and neutron resonance capture analysis combined with prompt-γ-ray analysis (NRCA/PGA). Although quantification of SNM will predominantly rely on NRTA, this will be hampered by the presence of strong neutron-absorbing matrix materials, in particular 10B. Results obtained with NRCA/PGA are used to improve the interpretation of NRTA data. Prompt γ rays originating from the 10B(n, αγ) reaction are used to assess the amount of 10B. The 478 keV γ rays from 10B, however, need to be measured under a high-radiation environment, especially because of 137Cs. To meet this requirement, we developed a well-shaped γ-ray spectrometer consisting of one cylindrical and four rectangular-cuboid LaBr3 scintillators combined with a fast data-acquisition system. Furthermore, to improve the gain stability of the main detector, a special high-voltage divider was developed. Because of the reduction in gain shift, a 3.8% resolution at 662 keV was obtained for long-term measurements. By using the data-acquisition system, which consists of eight 250 MHz digitizers, input signals of over 500 kHz per channel were recorded. The work reported herein demonstrates that, with such a spectrometer, the impact of the Compton edge of 662 keV γ rays from 137Cs is significantly reduced, which allows the 10B amount to be determined with greater sensitivity.
A Stochastic Imaging Technique for Spatio-Spectral Characterization of Special Nuclear Material
NASA Astrophysics Data System (ADS)
Hamel, Michael C.
Radiation imaging is advantageous for detecting, locating and characterizing special nuclear material (SNM) in complex environments. A dual-particle imager (DPI) has been designed that is capable of detecting gamma-ray and neutron signatures from shielded SNM. The system combines liquid organic and NaI(Tl) scintillators to form a combined Compton and neutron scatter camera. Effective image reconstruction of detected particles is a crucial component for maximizing the performance of the system; however, a key deficiency exists in the widely used list-mode maximum-likelihood estimation-maximization (MLEM) image reconstruction technique. The steady-state solution produced by this iterative method will have poor quality compared to solutions produced with fewer iterations. A stopping condition is required to achieve a better solution but these conditions fail to achieve maximum image quality. Stochastic origin ensembles (SOE) imaging is a good candidate to address this problem as it uses Markov chain Monte Carlo to reach a stochastic steady-state solution that has image quality comparable to the best MLEM solution. The application of SOE to the DPI is presented in this work. SOE was originally applied in medical imaging applications with no mechanism to isolate spectral information based on location. This capability is critical for non-proliferation applications as complex radiation environments with multiple sources are often encountered. This dissertation extends the SOE algorithm to produce spatially dependent spectra and presents experimental result showing that the technique was effective for isolating a 4.1-kg mass of weapons grade plutonium (WGPu) when other neutron and gamma-ray sources were present. This work also demonstrates the DPI as an effective tool for localizing and characterizing highly enriched uranium (HEU). A series of experiments were performed with the DPI using a deuterium-deuterium (DD) and deuterium-tritium (DT) neutron generator, as well as AmLi, to interrogate a 13.7-kg sphere of HEU. In all cases, the neutrons and gamma rays produced from induced fission were successfully discriminated from the interrogating particles to localize the HEU. For characterization, the fast neutron and gamma-ray spectra were recorded from multiple HEU configurations with low-Z and high-Z moderation. Further characterization of the configurations used the measured neutron lifetime to show that the DPI can be used to infer multiplication.
NASA Astrophysics Data System (ADS)
Lockhart, M.; Henzlova, D.; Croft, S.; Cutler, T.; Favalli, A.; McGahee, Ch.; Parker, R.
2018-01-01
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli(DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. The current paper discusses and presents the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. In order to assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. The DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-12
... use SNM to experimentally acquire hydro-mechanical properties of single fuel elements. The fuel... proceeding; (2) the nature and extent of the petitioner's property, financial, or other interest in the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
... Accounting Regulations and Proposed Guidance for Fuel Cycle Facility Material Control and Accounting Plans... accounting (MC&A) of special nuclear material (SNM). The public meeting has been rescheduled for January 9...
Microchannel plate special nuclear materials sensor
NASA Astrophysics Data System (ADS)
Feller, W. B.; White, P. L.; White, P. B.; Siegmund, O. H. W.; Martin, A. P.; Vallerga, J. V.
2011-10-01
Nova Scientific Inc., is developing for the Domestic Nuclear Detection Office (DNDO SBIR #HSHQDC-08-C-00190), a solid-state, high-efficiency neutron detection alternative to 3He gas tubes, using neutron-sensitive microchannel plates (MCPs) containing 10B and/or Gd. This work directly supports DNDO development of technologies designed to detect and interdict nuclear weapons or illicit nuclear materials. Neutron-sensitized MCPs have been shown theoretically and more recently experimentally, to be capable of thermal neutron detection efficiencies equivalent to 3He gas tubes. Although typical solid-state neutron detectors typically have an intrinsic gamma sensitivity orders of magnitude higher than that of 3He gas detectors, we dramatically reduce gamma sensitivity by combining a novel electronic coincidence rejection scheme, employing a separate but enveloping gamma scintillator. This has already resulted in a measured gamma rejection ratio equal to a small 3He tube, without in principle sacrificing neutron detection efficiency. Ongoing improvements to the MCP performance as well as the coincidence counting geometry will be described. Repeated testing and validation with a 252Cf source has been underway throughout the Phase II SBIR program, with ongoing comparisons to a small commercial 3He gas tube. Finally, further component improvements and efforts toward integration maturity are underway, with the goal of establishing functional prototypes for SNM field testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geddes, Cameron; Ludewigt, Bernhard; Valentine, John
Near-monoenergetic photon sources (MPSs) have the potential to improve sensitivity at greatly reduced dose in existing applications and enable new capabilities in other applications. MPS advantages include the ability to select energy, energy spread, flux, and pulse structures to deliver only the photons needed for the application, while suppressing extraneous dose and background. Some MPSs also offer narrow divergence photon beams which can target dose and/or mitigate scattering contributions to image contrast degradation. Current broad-band, bremsstrahlung photon sources (e.g., linacs and betatrons) deliver unnecessary dose that in some cases also interferes with the signature to be detected and/or restricts operations,more » and must be collimated (reducing flux) to generate narrow divergence beams. While MPSs can in principle resolve these issues, they are technically challenging to produce. Candidate MPS technologies for nonproliferation applications are now being developed, each of which have different properties (e.g. broad divergence vs. narrow). Within each technology, source parameters trade off against one another (e.g. flux vs. energy spread), representing a large operation space. To guide development, requirements for each application of interest must be defined and simulations conducted to define MPS parameters that deliver benefit relative to current systems. The present project conducted a broad assessment of potential nonproliferation applications where MPSs may provide new capabilities or significant performance enhancement (reported separately), which led to prioritization of several applications for detailed analysis. The applications prioritized were: cargo screening and interdiction of Special Nuclear Materials (SNM), detection of hidden SNM, treaty/dismantlement verification, and spent fuel dry storage cask content verification. High resolution imaging for stockpile stewardship was considered as a sub-area of the treaty topic, as it is also of interest for future treaty use. This report presents higher-fidelity calculations and modeling results to quantitatively evaluate the prioritized applications, and to derive the key MPS properties that drive application benefit. Simulations focused on the conventional signatures of radiography, photofission, and NRF to enable comparison to present methods and evaluation of benefit.« less
Disposition of fuel elements from the Aberdeen and Sandia pulse reactor (SPR-II) assemblies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mckerley, Bill; Bustamante, Jacqueline M; Costa, David A
2010-01-01
We describe the disposition of fuel from the Aberdeen (APR) and the Sandia Pulse Reactors (SPR-II) which were used to provide intense neutron bursts for radiation effects testing. The enriched Uranium - 10% Molybdenum fuel from these reactors was shipped to the Los Alamos National Laboratory (LANL) for size reduction prior to shipment to the Savannah River Site (SRS) for final disposition in the H Canyon facility. The Shipper/Receiver Agreements (SRA), intra-DOE interfaces, criticality safety evaluations, safety and quality requirements and key materials management issues required for the successful completion of this project will be presented. This work is inmore » support of the DOE Consolidation and Disposition program. Sandia National Laboratories (SNL) has operated pulse nuclear reactor research facilities for the Department of Energy since 1961. The Sandia Pulse Reactor (SPR-II) was a bare metal Godiva-type reactor. The reactor facilities have been used for research and development of nuclear and non-nuclear weapon systems, advanced nuclear reactors, reactor safety, simulation sources and energy related programs. The SPR-II was a fast burst reactor, designed and constructed by SNL that became operational in 1967. The SPR-ll core was a solid-metal fuel enriched to 93% {sup 235}U. The uranium was alloyed with 10 weight percent molybdenum to ensure the phase stabilization of the fuel. The core consisted of six fuel plates divided into two assemblies of three plates each. Figure 1 shows a cutaway diagram of the SPR-II Reactor with its decoupling shroud. NNSA charged Sandia with removing its category 1 and 2 special nuclear material by the end of 2008. The main impetus for this activity was based on NNSA Administrator Tom D'Agostino's six focus areas to reenergize NNSA's nuclear material consolidation and disposition efforts. For example, the removal of SPR-II from SNL to DAF was part of this undertaking. This project was in support of NNSA's efforts to consolidate the locations of special nuclear material (SNM) to reduce the cost of securing many SNM facilities. The removal of SPR-II from SNL was a significant accomplishment in SNL's de-inventory efforts and played a key role in reducing the number of locations requiring the expensive security measures required for category 1 and 2 SNM facilities. A similar pulse reactor was fabricated at the Y-12 National Security Complex beginning in the late 1960's. This Aberdeen Pulse Reactor (APR) was operated at the Army Pulse Radiation Facility (APRF) located at the Aberdeen Test Center (ATC) in Maryland. When the APRF was shut down in 2003, a portion of the DOE-owned Special Nuclear Material (SNM) was shipped to an interim facility for storage. Subsequently, the DOE determined that the material from both the SPR-II and the APR would be processed in the H-Canyon at the Savannah River Site (SRS). Because of the SRS receipt requirements some of the material was sent to the Los Alamos National Laboratory (LANL) for size-reduction prior to shipment to the SRS for final disposition.« less
77 FR 28407 - Special Nuclear Material Control and Accounting Systems for Nuclear Power Plants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-14
... and Management System (ADAMS): You may access publicly-available documents online in the NRC Library... revised ANSI N15.8 in February 2009. ANSI N15.8-2009 provides guidance on the fundamentals of an SNM...
Lockhart, M.; Henzlova, D.; Croft, S.; ...
2017-09-20
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lockhart, M.; Henzlova, D.; Croft, S.
Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less
Hüttenhofer, Alexander; Kiefmann, Martin; Meier-Ewert, Sebastian; O’Brien, John; Lehrach, Hans; Bachellerie, Jean-Pierre; Brosius, Jürgen
2001-01-01
In mouse brain cDNA libraries generated from small RNA molecules we have identified a total of 201 different expressed RNA sequences potentially encoding novel small non-messenger RNA species (snmRNAs). Based on sequence and structural motifs, 113 of these RNAs can be assigned to the C/D box or H/ACA box subclass of small nucleolar RNAs (snoRNAs), known as guide RNAs for rRNA. While 30 RNAs represent mouse homologues of previously identified human C/D or H/ACA snoRNAs, 83 correspond to entirely novel snoRNAs. Among these, for the first time, we identified four C/D box snoRNAs and four H/ACA box snoRNAs predicted to direct modifications within U2, U4 or U6 small nuclear RNAs (snRNAs). Furthermore, 25 snoRNAs from either class lacked antisense elements for rRNAs or snRNAs. Therefore, additional snoRNA targets have to be considered. Surprisingly, six C/D box snoRNAs and one H/ACA box snoRNA were expressed exclusively in brain. Of the 88 RNAs not belonging to either snoRNA subclass, at least 26 are probably derived from truncated heterogeneous nuclear RNAs (hnRNAs) or mRNAs. Short interspersed repetitive elements (SINEs) are located on five RNA sequences and may represent rare examples of transcribed SINEs. The remaining RNA species could not as yet be assigned either to any snmRNA class or to a part of a larger hnRNA/mRNA. It is likely that at least some of the latter will represent novel, unclassified snmRNAs. PMID:11387227
Conventional and Non-Conventional Nuclear Material Signatures
NASA Astrophysics Data System (ADS)
Gozani, Tsahi
2009-03-01
The detection and interdiction of concealed special nuclear material (SNM) in all modes of transport is one of the most critical security issues facing the United States and the rest of the world. In principle, detection of nuclear materials is relatively easy because of their unique properties: all of them are radioactive and all emit some characteristic gamma rays. A few emit neutrons as well. These signatures are the basis for passive non-intrusive detection of nuclear materials. The low energy of the radiations necessitates additional means of detection and validation. These are provided by high-energy x-ray radiography and by active inspection based on inducing nuclear reactions in the nuclear materials. Positive confirmation that a nuclear material is present or absent can be provided by interrogation of the inspected object with penetrating probing radiation, such as neutrons and photons. The radiation induces specific reactions in the nuclear material yielding, in turn, penetrating signatures which can be detected outside the inspected object. The "conventional" signatures are first and foremost fission signatures: prompt and delayed neutrons and gamma rays. Their intensity (number per fission) and the fact that they have broad energy (non-discrete, though unique) distributions and certain temporal behaviors are key to their use. The "non- conventional" signatures are not related to the fission process but to the unique nuclear structure of each element or isotope in nature. This can be accessed through the excitation of isotopic nuclear levels (discrete and continuum) by neutron inelastic scattering or gamma resonance fluorescence. Finally there is an atomic signature, namely the high atomic number (Z>74), which obviously includes all the nuclear materials and their possible shielding. The presence of such high-Z elements can be inferred by techniques using high-energy x rays. The conventional signatures have been addressed in another article. Non-conventional signatures and some of their current or potential uses will be discussed here.
Code of Federal Regulations, 2012 CFR
2012-01-01
... of neutrons used to effect SNM production in the “subcritical assembly.” Agreement for cooperation... International Atomic Energy Agency. Non-nuclear-weapon state is a country not recognized as a nuclear-weapon...-Proliferation of Nuclear Weapons. Nuclear reactor means an apparatus, other than a nuclear explosive device...
Code of Federal Regulations, 2013 CFR
2013-01-01
... of neutrons used to effect SNM production in the “subcritical assembly.” Agreement for cooperation... International Atomic Energy Agency. Non-nuclear-weapon state is a country not recognized as a nuclear-weapon...-Proliferation of Nuclear Weapons. Nuclear reactor means an apparatus, other than a nuclear explosive device...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-24
... CONTACT: Rafael L. Rodriguez, Project Manager, Fuel Manufacturing Branch, Division of Fuel Cycle Safety..., Rockville, MD 20852. Telephone: (301) 492-3111; Fax Number: (301) 492-3363; E-mail: Rafael[email protected
78 FR 67225 - Amendments to Material Control and Accounting Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... Amendments to Material Control and Accounting Regulations AGENCY: Nuclear Regulatory Commission. ACTION... for material control and accounting (MC&A) of special nuclear material (SNM). The goal of this... added to designate material balance areas, item control areas, and custodians? N. Why would calendar...
Peters, Kenneth M; Jayabalan, Nirmal; Bui, Don; Killinger, Kim; Chancellor, Michael; Tyagi, Pradeep
2015-05-01
Sacral neuromodulation (SNM) may improve interstitial cystitis/painful bladder syndrome (IC/BPS) symptoms of urinary frequency, urgency and perhaps even pain, but objective measures of improvement are lacking. We evaluated the potential for urinary chemokines to serve as measures of treatment response over time to SNM. Women with IC/BPS undergoing SNM consented for this study. Three-day bladder/pain diaries were collected at baseline and validated Interstitial Cystitis Symptom Problem Index (ICSPI) scores and mid-stream urine specimens were collected at baseline and at 24 weeks after successful implant. Collected urine was screened for infection by dipstick and analyzed for chemokines by luminex xMAP analysis. At baseline (n = 16), urine levels of CXCL-1 positively correlated with pain score (r = 0.63, P = 0.009), urgency (r = 0.61, P = 0.01), ICSPI (r = 0.43, P = 0.09) and daily voids (r = 0.44, P = 0.08). ICSPI and pain scores also positively correlated with sIL-1ra (r = 0.50, P = 0.04) and monocyte chemotactic protein-1 (MCP-1) or CCL2 positively correlated with daily voids (r = 0.45, P = 0.07) only. At 24 weeks, the median ICSPI index fell from 28 to 15 (n = 7, P = 0.008). Urine levels of sIL-1ra (633.8 ± 188.2 vs. 149.9 ± 41.62 pg/mL) and MCP-1 (448.3 ± 11.6 vs. 176.9 ± 46.16 pg/mL) and CCL5 (20.78 ± 4.09 vs. 11.21 ± 4.12 pg/mL) were also significantly reduced at the follow-up relative to baseline values (P = 0.04). Multivariable analysis of data revealed that sIL-1ra and MCP-1 together explained the majority of variance in data. Levels of CXCL-1, CXCL-10, interleukin (IL)-8, vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF) were also reduced at 24 weeks, but differences were not significant. Concomitant decrease in urine levels of chemokines especially MCP-1 was associated with treatment response of SNM. These results support the role of chemokines as downstream effectors of neuromodulation response and could serve as potential non-invasive measures of treatment response. NCT01739946. © 2014 Wiley Publishing Asia Pty Ltd.
Cosmic Ray Inspection and Passive Tomography for SNM Detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armitage, John; Oakham, Gerald; Bryman, Douglas
2009-12-02
The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or amore » subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.« less
Cosmic Ray Inspection and Passive Tomography for SNM Detection
NASA Astrophysics Data System (ADS)
Armitage, John; Bryman, Douglas; Cousins, Thomas; Gallant, Grant; Jason, Andrew; Jonkmans, Guy; Noël, Scott; Oakham, Gerald; Stocki, Trevor J.; Waller, David
2009-12-01
The Cosmic Ray Inspection and Passive Tomography (CRIPT) project has recently started investigating the detection of illicit Special Nuclear Material in cargo using cosmic ray muon tomography and complementary neutron detectors. We are currently performing simulation studies to help with the design of small scale prototypes. Based on the prototype tests and refined simulations, we will determine whether the muon tracking system for the full scale prototype will be based on drift chambers or extruded scintillator trackers. An analysis of the operations of the Port of Montreal has determined how long muon scan times should take if all or a subset of the cargo is to be screened. As long as the throughput of the muon system(s) is equal to the rate at which containers are unloaded from ships, the impact on port operations would not be great if a muon scanning stage were required for all cargo. We also show preliminary simulation results indicating that excellent separation between Al, Fe and Pb is possible under ideal conditions. The discrimination power is reduced but still significant when realistic momentum resolution measurements are considered.
NASA Astrophysics Data System (ADS)
Kane, Steven Ze
A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo containers uniformly filled with wood (low-Z) or iron (high-Z) at densities ranging from 0.1 g/cm3 to 0.4 g/cm3, the maximal density for a uniformly fully loaded 40-ft standard cargo container. In addition, samples were located at the center of a given container to study worst-case scenarios. The RAPID technique allows for the interrogation of containers at neutron production rates between 1x108 neutrons/s and 4x108 neutrons/s, depending on cargo material and density. These rates are low enough to prevent transmutation of materials in cargo and radiation safety hazards are limited. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10-4 false positive rate per interrogated voxel of cargo. The detection of 5-kg of U-235 was chosen because this quantity of material is near the lower limit of the amount of special nuclear material that might be used in a nuclear weapon. This is in contrast to the 25-kg suggested sensitivity proposed by the International Atomic Energy Agency (IAEA).
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-14
... NUCLEAR REGULATORY COMMISSION [Docket No. 72-8; NRC-2010-0011] Constellation Energy; Notice of... Independent Spent Fuel Storage Installation AGENCY: Nuclear Regulatory Commission. ACTION: Notice of license..., Division of Spent Fuel Storage and Transportation, Office of Nuclear Material Safety and Safeguards, U.S...
Code of Federal Regulations, 2010 CFR
2010-01-01
... pursuant to section 142 of the Atomic Energy Act. Sensitive nuclear technology means any information... nuclear material (SNM) or which a U.S. provider of assistance knows or has reason to know will be used for... International Atomic Energy Agency. Non-nuclear-weapon state is a country not recognized as a nuclear-weapon...
32 CFR 223.5 - Responsibilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... regarding nuclear weapons security and the protection of SNM at DoD nuclear reactor facilities as DoD UCNI... UNCLASSIFIED CONTROLLED NUCLEAR INFORMATION (UCNI) § 223.5 Responsibilities. (a) The Under Secretary of Defense... compliance with the DOE program for controlling DOE UCNI. (b) The Assistant Secretary of Defense for Nuclear...
32 CFR 223.5 - Responsibilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... regarding nuclear weapons security and the protection of SNM at DoD nuclear reactor facilities as DoD UCNI... UNCLASSIFIED CONTROLLED NUCLEAR INFORMATION (UCNI) § 223.5 Responsibilities. (a) The Under Secretary of Defense... compliance with the DOE program for controlling DOE UCNI. (b) The Assistant Secretary of Defense for Nuclear...
Do "Clicker" Educational Sessions Enhance the Effectiveness of a Social Norms Marketing Campaign?
ERIC Educational Resources Information Center
Killos, Lydia F.; Hancock, Linda C.; McGann, Amanda Wattenmaker; Keller, Adrienne E.
2010-01-01
Objective: Social norms campaigns are a cost-effective way to reduce high-risk drinking on college campuses. This study compares effectiveness of a "standard" social norms media (SNM) campaign for those with and without exposure to additional educational sessions using audience response technology ("clickers"). Methods: American College Health…
10 CFR 73.71 - Reporting of safeguards events.
Code of Federal Regulations, 2011 CFR
2011-01-01
... after discovery of the loss of any shipment of SNM or spent fuel, and within one hour after recovery of... Notification System, if the licensee is party to that system. If the Emergency Notification System is... service or other dedicated telephonic system or any other methods that will ensure that a report is...
10 CFR 73.71 - Reporting of safeguards events.
Code of Federal Regulations, 2010 CFR
2010-01-01
... after discovery of the loss of any shipment of SNM or spent fuel, and within one hour after recovery of... Notification System, if the licensee is party to that system. If the Emergency Notification System is... service or other dedicated telephonic system or any other methods that will ensure that a report is...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
... the following methods: NRC's Public Document Room (PDR): The public may examine and have copied, for a... Manager, Fuel Manufacturing Branch, Division of Fuel Cycle Safety and Safeguards, Office of Nuclear... systems. The SNM would be used as test objects for concept demonstrations and characterization testing...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-13
... Application for Special Nuclear Materials License From Passport Systems, Inc., Opportunity To Request a... special nuclear material (SNM), submitted by Passport Systems, Inc. (Passport or the Applicant). The..., if approved, would authorize Passport to possess and use special nuclear materials under 10 CFR Part...
77 FR 43506 - DoD Unclassified Controlled Nuclear Information (UCNI)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
... Systems. (i) Information on the layout or design of security and alarm systems at a specific DoD SNM or... information is not observable from a public area. (iii) Performance characteristics of installed systems. (5... 0790-AI64 DoD Unclassified Controlled Nuclear Information (UCNI) AGENCY: Department of Defense. ACTION...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... Nuclear Materials and Equipment * Nuclear Regulatory Commission, Office of International Programs, Tel. (301) 415-2344, Fax: (301) 415-2395. 10 CFR part 110. Nuclear Technologies and Services Which Contribute to the Production of Special Nuclear Material (Snm). Technologies Covered Include Nuclear Reactors...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... Nuclear Technologies and Services Which Contribute to the Production of Special Nuclear Material (Snm). Technologies Covered Include Nuclear Reactors, Enrichment, Reprocessing, Fuel Fabrication, and Heavy Water...-6050. 10 CFR 205.300 through 205.379 and part 590. Nuclear Materials and Equipment * Nuclear Regulatory...
Invasive Scalp Melanoma: Role for Enhanced Detection Through Professional Training.
Lovasik, Brendan P; Sharma, Ishna; Russell, Maria C; Carlson, Grant W; Delman, Keith A; Rizzo, Monica
2016-11-01
Scalp and neck melanomas (SNMs) have a relatively poor prognosis compared to other sites, and represent an anatomically challenging area for detection. The aim of this study was to identify the role of the hairdresser in detection of SNMs. A tertiary surgical oncology institutional database was retrospectively reviewed for all patients undergoing resection of a scalp, posterior neck, or retro auricular invasive primary melanoma between 2008 and 2014. SNMs accounted for 128 melanoma patients during the study period, with median age 66 years, 88 % male, and median Breslow thickness 1.55 mm. Hairdressers detected 10 % of all SNMs, with hairdresser-detected SNMs presenting 13 years younger (53 vs. 66 years, P = 0.015), and with a trend towards lower Breslow depth (1.15 vs. 1.63) and more frequent discovery in AJCC Stage Ia or Ib (66.7 % vs. 44.8 %) than otherwise-detected SNMs. Women with SNMs were 1.8-fold more likely than men to have their SNMs detected by a hairdresser (P = 0.001), and presented at higher AJCC clinical stage than men and required wider surgical resection margins (P = 0.011). Women with hairdresser-detected SNMs were younger, with lower Breslow thickness and lower AJCC Clinical Stage than women with otherwise-detected SNM. This study suggests that hairdressers play a critical role in detection of invasive primary scalp and neck melanoma, accounting for 10 % of all melanomas referred to a tertiary surgical oncology center. Quality improvement initiatives aimed at increasing early detection of scalp and neck melanoma should include members of the cosmetology community.
The neutron skin thickness in nuclei with clustering at low densities
NASA Astrophysics Data System (ADS)
Nooraihan, A.; Usmani, Q. N.; Sauli, Z.; Anwar, K.
2016-11-01
This study concentrates on searching for a dependable, fully microscopic theory to find out new behaviours and understand their consequences for theoretical pictures. The models for nuclear structure are tested, refined and developed by acquiring new data [1][2][3]. This data is useful for astrophysical calculations and predictions. In density functional theories, including the ETF theory, the equation of state (EOS) of symmetric nuclear matter (SNM), is an important measure. Empirically, we receive information about quantities relating to SNM, all these measures are thoroughly tested. In the absence of any unswerving knowledge below this density we shall take that energy still rises up to some density, neglecting possible small fluctuations, as the density is brought down. Our discussion at the moment is without the Coulomb forces applicable only for the hypothetical nuclear matter; they are added finally to correctly portray the actual picture in nuclei. Our approach in this study is macroscopic. This work concludes that the neutron skin thickness in nuclei is found to reduce significantly, for the reason of clustering.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleaford, B W; Collins, B A; Ebbinghaus, B B
2010-04-26
This paper examines the attractiveness of material mixtures containing special nuclear materials (SNM) associated with reprocessing and the thorium-based LWR fuel cycle. This paper expands upon the results from earlier studies that examined the attractiveness of SNM associated with the reprocessing of spent light water reactor (LWR) fuel by various reprocessing schemes and the recycle of plutonium as a mixed oxide (MOX) fuel in LWR. This study shows that {sup 233}U that is produced in thorium-based fuel cycles is very attractive for weapons use. Consistent with other studies, these results also show that all fuel cycles examined to date needmore » to be rigorously safeguarded and provided moderate to high levels of physical protection. These studies were performed at the request of the United States Department of Energy (DOE), and are based on the calculation of 'attractiveness levels' that has been couched in terms chosen for consistency with those normally used for nuclear materials in DOE nuclear facilities. The methodology and key findings will be presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleaford, Brad W.; Ebbinghaus, B. B.; Bradley, Keith S.
2010-06-11
This paper examines the attractiveness of material mixtures containing special nuclear materials (SNM) associated with reprocessing and the thorium-based LWR fuel cycle. This paper expands upon the results from earlier studies [ , ] that examined the attractiveness of SNM associated with the reprocessing of spent light water reactor (LWR) fuel by various reprocessing schemes and the recycle of plutonium as a mixed oxide (MOX) fuel in LWR. This study shows that 233U that is produced in thorium-based fuel cycles is very attractive for weapons use. Consistent with other studies, these results also show that all fuel cycles examined tomore » date need to be rigorously safeguarded and provided moderate to high levels of physical protection. These studies were performed at the request of the United States Department of Energy (DOE), and are based on the calculation of "attractiveness levels" that has been couched in terms chosen for consistency with those normally used for nuclear materials in DOE nuclear facilities [ ]. The methodology and key findings will be presented.« less
Zhang, Wanqin; Lang, Qianqian; Wu, Shubiao; Li, Wei; Bah, Hamidou; Dong, Renjie
2014-03-01
The characteristics of anaerobic digestion of pig manure from different growth stages were investigated. According to growth stage, batch experiments were performed using gestating sow manure (GSM), swine nursery with post-weaned piglet manure (SNM), growing fattening manure (GFM) and mixed manure (MM) as substrates at four substrate concentrations (40, 50, 65 and 80gVS/L) under mesophilic conditions. The maximum methane yields of MM, SNM, GSM and GFM were 354.7, 328.7, 282.4 and 263.5mLCH4/gVSadded, respectively. Volatile fatty acids/total inorganic carbon (VFA/TIC) ratio increased from 0.10 to 0.89 when loading increased from 40 to 80gVS/L for GFM. The modified Gompertz model shows a better fit to the experimental results than the first order model with a lower difference between measured and predicted methane yields. The kinetic parameters indicated that the methane production curve on the basis of differences in biodegradability of the pig manure at different growth stages. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donnelly, H.; Fullwood, R.; Glancy, J.
This is the second volume of a two volume report on the VISA method for evaluating safeguards at fixed-site facilities. This volume contains appendices that support the description of the VISA concept and the initial working version of the method, VISA-1, presented in Volume I. The information is separated into four appendices, each describing details of one of the four analysis modules that comprise the analysis sections of the method. The first appendix discusses Path Analysis methodology, applies it to a Model Fuel Facility, and describes the computer codes that are being used. Introductory material on Path Analysis given inmore » Chapter 3.2.1 and Chapter 4.2.1 of Volume I. The second appendix deals with Detection Analysis, specifically the schemes used in VISA-1 for classifying adversaries and the methods proposed for evaluating individual detection mechanisms in order to build the data base required for detection analysis. Examples of evaluations on identity-access systems, SNM portal monitors, and intrusion devices are provided. The third appendix describes the Containment Analysis overt-segment path ranking, the Monte Carlo engagement model, the network simulation code, the delay mechanism data base, and the results of a sensitivity analysis. The last appendix presents general equations used in Interruption Analysis for combining covert-overt segments and compares them with equations given in Volume I, Chapter 3.« less
Conceptual design report: Nuclear materials storage facility renovation. Part 6, Alternatives study
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-07-14
The Nuclear Materials Storage Facility (NMSF) at the Los Alamos National Laboratory (LANL) was a Fiscal Year (FY) 1984 line-item project completed in 1987 that has never been operated because of major design and construction deficiencies. This renovation project, which will correct those deficiencies and allow operation of the facility, is proposed as an FY 97 line item. The mission of the project is to provide centralized intermediate and long-term storage of special nuclear materials (SNM) associated with defined LANL programmatic missions and to establish a centralized SNM shipping and receiving location for Technical Area (TA)-55 at LANL. Based onmore » current projections, existing storage space for SNM at other locations at LANL will be loaded to capacity by approximately 2002. This will adversely affect LANUs ability to meet its mission requirements in the future. The affected missions include LANL`s weapons research, development, and testing (WRD&T) program; special materials recovery; stockpile survelliance/evaluation; advanced fuels and heat sources development and production; and safe, secure storage of existing nuclear materials inventories. The problem is further exacerbated by LANL`s inability to ship any materials offsite because of the lack of receiver sites for material and regulatory issues. Correction of the current deficiencies and enhancement of the facility will provide centralized storage close to a nuclear materials processing facility. The project will enable long-term, cost-effective storage in a secure environment with reduced radiation exposure to workers, and eliminate potential exposures to the public. This report is organized according to the sections and subsections outlined by Attachment 111-2 of DOE Document AL 4700.1, Project Management System. It is organized into seven parts. This document, Part VI - Alternatives Study, presents a study of the different storage/containment options considered for NMSF.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-26
... licenses for nuclear power plants and spent fuel storage facilities from the current holder, Constellation... Independent Spent Fuel Storage Installation (ISFSI) Materials License No. SNM-2505; Nine Mile Point Nuclear.... A request for a hearing must be filed by January 15, 2014. Any potential party as defined in Sec. 2...
Initial results from a multiple monoenergetic gamma radiography system for nuclear security
NASA Astrophysics Data System (ADS)
O'Day, Buckley E.; Hartwig, Zachary S.; Lanza, Richard C.; Danagoulian, Areg
2016-10-01
The detection of assembled nuclear devices and concealed special nuclear materials (SNM) such as plutonium or uranium in commercial cargo traffic is a major challenge in mitigating the threat of nuclear terrorism. Currently available radiographic and active interrogation systems use ∼1-10 MeV bremsstrahlung photon beams. Although simple to build and operate, bremsstrahlung-based systems deliver high radiation doses to the cargo and to potential stowaways. To eliminate problematic issues of high dose, we are developing a novel technique known as multiple monoenergetic gamma radiography (MMGR). MMGR uses ion-induced nuclear reactions to produce two monoenergetic gammas for dual-energy radiography. This allows us to image the areal density and effective atomic number (Zeff) of scanned cargo. We present initial results from the proof-of-concept experiment, which was conducted at the MIT Bates Research and Engineering Center. The purpose of the experiment was to assess the capabilities of MMGR to measure areal density and Zeff of container cargo mockups. The experiment used a 3.0 MeV radiofrequency quadrupole accelerator to create sources of 4.44 MeV and 15.11 MeV gammas from the 11B(d,nγ)12C reaction in a thick natural boron target; the gammas are detected by an array of NaI(Tl) detectors after transmission through cargo mockups . The measured fluxes of transmitted 4.44 MeV and 15.11 MeV gammas were used to assess the areal density and Zeff. Initial results show that MMGR is capable of discriminating the presence of high-Z materials concealed in up to 30 cm of iron shielding from low- and mid-Z materials present in the cargo mockup.
Design and fabrication of a novel self-powered solid-state neutron detector
NASA Astrophysics Data System (ADS)
LiCausi, Nicholas
There is a strong interest in intercepting special nuclear materials (SNM) at national and international borders and ports for homeland security applications. Detection of SNM such as U and Pu is often accomplished by sensing their natural or induced neutron emission. Such detector systems typically use thermal neutron detectors inside a plastic moderator. In order to achieve high detection efficiency gas filled detectors are often used; these detectors require high voltage bias for operation, which complicates the system when tens or hundreds of detectors are deployed. A better type of detector would be an inexpensive solid-state detector that can be mass-produced like any other computer chip. Research surrounding solid-state detectors has been underway since the late 1990's. A simple solid-state detector employs a planar solar-cell type p-n junction and a thin conversion material that converts incident thermal neutrons into detectable alpha-particles and 7Li ions. Existing work has typically used 6LiF or 10B as this conversion layer. Although a simple planar detector can act as a highly portable, low cost detector, it is limited to relatively low detection efficiency (˜10%). To increase the efficiency, 3D perforated p-i-n silicon devices were proposed. To get high efficiency, these detectors need to be biased, resulting in increased leakage current and hence detector noise. In this research, a new type of detector structure was proposed, designed and fabricated. Among several detector structures evaluated, a honeycomb-like silicon p-n structure was selected, which is filled with natural boron as the neutron converter. A silicon p+-n diode formed on the thin silicon wall of the honeycomb structure detects the energetic alpha-particles emitted from the boron conversion layer. The silicon detection layer is fabricated to be fully depleted with an integral step during the boron filling process. This novel feature results in a simplified fabrication process. Three key advantages of the novel devices are theoretical neutron detection efficiency of ˜48%, a self-passivating structure that reduces leakage current and detector operation with no bias resulting in extremely low device noise. Processes required to fabricate the 3D type detector were explored and developed in this thesis. The detector capacitance and processing steps have been simulated with MEDICI and TSuprem-4, respectively. Lithography masks were then designed using Cadence. The fabrication process development was conducted in line with standard CMOS grade integrated circuit processing to allow for simple integration with existing fabrication facilities. A number of new processes were developed including the low pressure chemical vapor deposition of conformal boron films using diborane on very high aspect-ratio trenches and holes. Development also included methods for "wet" chemical etching and "dry" reactive ion etching of the deposited boron films. Fabricated detectors were characterized with the transmission line method, 4-point probe, I-V measurements and C-V measurements. Finally the detector response to thermal neutrons was studied. Characterization has shown significant reduction in reverse leakage current density to ˜8x10-8 A/cm2 (nearly 4 orders of magnitude over the previously published data). Results show that the fabrication process developed is capable of producing efficient (˜22.5%) solid-state thermal neutron detectors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
England, Jeffery L.; Adams, Karen; Maxted, Maxcine
2013-07-01
The Department of Energy (DOE) is working to de-inventory sites and consolidate hazardous materials for processing and disposal. The DOE administers a wide range of certified shipping packages for the transport of hazardous materials to include Special Nuclear Material (SNM), radioactive materials, sealed sources and radioactive wastes. A critical element to successful and safe transportation of these materials is the availability of certified shipping packages. There are over seven thousand certified packagings (i.e., Type B/Type AF) utilized within the DOE for current missions. The synergistic effects of consolidated maintenance, refurbishment, testing, certification, and costing of these services would allow formore » efficient management of the packagings inventory and to support anticipated future in-commerce shipping needs. The Savannah River Site (SRS) receives and ships radioactive materials (including SNM) and waste on a regular basis for critical missions such as consolidated storage, stabilization, purification, or disposition using H-Canyon and HB-Line. The Savannah River National Laboratory (SRNL) has the technical capability and equipment for all aspects of packaging management. SRS has the only active material processing facility in the DOE complex and is one of the sites of choice for nuclear material consolidation. SRS is a logical location to perform maintenance and periodic testing of the DOE fleet of certified packagings. This initiative envisions a DOE Eastern Packaging Staging and Maintenance Center (PSMC) at the SRS and a western hub at the Nevada National Security Site (NNSS), an active DOE Regional Disposal Site. The PSMC's would be the first place DOE would go to meet their radioactive packaging needs and the primary locations projects would go to disposition excess packaging for beneficial reuse. These two hubs would provide the centralized management of a packaging fleet rather than the current approach to design, procure, maintain and dispose of packagings on a project-by-project basis. This initiative provides significant savings in packaging costs and acceleration of project schedules. In addition to certified packaging, the PSMC would be well suited for select designs of 7A Type A packaging and Industrial Packaging. (authors)« less
Code of Federal Regulations, 2010 CFR
2010-01-01
...: (301) 594-4715. 21 U.S.C. 301 et seq. Natural Gas and Electric Power Department of Energy, Office of.... (301) 415-2344, Fax: (301) 415-2395. 10 CFR part 110. Nuclear Technologies and Services Which Contribute to the Production of Special Nuclear Material (Snm). Technologies Covered Include Nuclear Reactors...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-04
... INFORMATION CONTACT: Pamela Longmire, Ph.D., Project Manager, Licensing Branch, Division of Spent Fuel Storage... Generating Plant (PINGP), Unit Nos. 1 and 2, site in Goodhue County, Minnesota. The TN-40 cask is currently..., higher burnup spent fuel used in the PINGP reactor as well as associated changes to the ISFSI's technical...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
..., relax or rescind any of the above conditions upon demonstration by the Licensee of good cause. V Any... within 20 days of its publication in the Federal Register. Where good cause is shown, consideration will..., and include a statement of good cause for the extension. All documents filed in NRC adjudicatory...
Code of Federal Regulations, 2011 CFR
2011-01-01
...: (301) 594-4715. 21 U.S.C. 301 et seq. Natural Gas and Electric Power Department of Energy, Office of.... (301) 415-2344, Fax: (301) 415-2395. 10 CFR part 110. Nuclear Technologies and Services Which Contribute to the Production of Special Nuclear Material (Snm). Technologies Covered Include Nuclear Reactors...
ERIC Educational Resources Information Center
DeJong, William; Schneider, Shari Kessel; Towvim, Laura Gomberg; Murphy, Melissa J.; Doerr, Emily E.; Simonsen, Neal R.; Mason, Karen E.; Scribner, Richard A.
2009-01-01
A 14-site randomized trial tested the effectiveness of social norms marketing (SNM) campaigns, which present accurate student survey data in order to correct misperceptions of subjective drinking norms and thereby drive down alcohol use. Cross-sectional student surveys were conducted by mail at baseline and at posttest 3 years later. Hierarchical…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... irradiation room at a panoramic irradiator be equipped with a fire extinguishing system capable of extinguishing a fire without the entry of personnel into the room. The system for the irradiation room must have... 10 CFR 36.27(b) is to deny the exemption request and require NIST to provide the irradiation room...
Hong, Feifei; Yan, Chengcheng; Si, Yang; He, Jianxin; Yu, Jianyong; Ding, Bin
2015-09-16
Many applications proposed for magnetic silica nanofibers require their assembly into a cellular membrane structure. The feature to keep structure stable upon large deformation is crucial for a macroscopic porous material which functions reliably. However, it remains a key issue to realize robust flexibility in two-dimensional (2D) magnetic silica nanofibrous networks. Here, we report that the combination of electrospun silica nanofibers with zein dip-coating can lead to the formation of flexible, magnetic, and hierarchical porous silica nanofibrous membranes (SNM). The 290 nm diameter silica nanofibers act as templates for the uniform anchoring of nickel ferrite nanoparticles (size of 50 nm). Benefiting from the homogeneous and stable nanofiber-nanoparticle composite structure, the resulting magnetic SNM can maintain their structure integrity under repeated bending as high as 180° and can facilely recover. The unique hierarchical structure also provides this new class of silica membrane with integrated properties of ultralow density, high porosity, large surface area, good magnetic responsiveness, robust dye adsorption capacity, and effective emulsion separation performance. Significantly, the synthesis of such fascinating membranes may provide new insight for further application of silica in a self-supporting, structurally adaptive, and 2D membrane form.
Rapid response sensor for analyzing Special Nuclear Material
Mitra, S. S.; Doron, O.; Chen, A. X.; ...
2015-06-18
Rapid in-situ analytical techniques are attractive for characterizing Special Nuclear Material (SNM). Present techniques are time consuming, and require sample dissolution. Proof-of-principal studies are performed to demonstrate the utility of employing low energy neutrons from a portable pulsed neutron generator for non-destructive isotopic analysis of nuclear material. In particular, time-sequenced data acquisition, operating synchronously with the pulsing of a neutron generator, partitions the characteristic elemental prompt gamma-rays according to the type of the reaction; inelastic neutron scattering reactions during the ON state and thermal neutron capture reactions during the OFF state of the generator. Thus, the key challenge is isolatingmore » these signature gamma- rays from the prompt fission and β-delayed gamma-rays that are also produced during the neutron interrogation. A commercial digital multi-channel analyzer has been specially customized to enable time-resolved gamma-ray spectral data to be acquired in multiple user-defined time bins within each of the ON/OFF gate periods of the neutron generator. Preliminary results on new signatures from depleted uranium as well as modeling and benchmarking of the concept are presented, however this approach should should be applicable for virtually all forms of SNM.« less
NASA Astrophysics Data System (ADS)
Rao, Cheng; Shen, Jiating; Wang, Fumin; Peng, Honggen; Xu, Xianglan; Zhan, Hangping; Fang, Xiuzhong; Liu, Jianjun; Liu, Wenming; Wang, Xiang
2018-03-01
In this study, SnO2-based catalysts promoted by different alkali metal oxides with a Sn/M (M = Li, Na, K, Cs) molar ratio of 9/1 have been prepared for soot combustion. In comparison with the un-modified SnO2 support, the activity of the modified catalysts has been evidently enhanced, following the sequence of CsSn1-9 > KSn1-9 > NaSn1-9 > LiSn1-9 > SnO2. As testified by Raman, H2-TPR, soot-TPR-MS, XPS and O2-TPD results, the incorporation of various alkali metal oxides can induce the formation of more abundant and mobile oxygen species on the surface of the catalysts. Moreover, quantified results have proved that the amount of the surface active oxygen species is nearly proportional to the activity of the catalysts. CsSn1-9, the catalyst promoted by cesium oxide, owns the largest amount of surface mobile oxygen species, thus having the highest activity among all the studied catalysts. It is concluded that the amount of surface active and mobile oxygen species is the major factor determining the activity of the catalysts for soot combustion.
Traditional and Model Based Assay of Irregular Geometry Items
DOE Office of Scientific and Technical Information (OSTI.GOV)
MOORE, FRANK S.; SALAYMEH, SALEEM
The Analytical Development Section (ADS) of SRNL was requested to perform a waste disposal assay of two heater boxes which had been used in the HB Line dissolvers. They had been sent to SRNL for study to make recommendations on how to prevent future failure of the units when they were replaced. The study having been completed, the units needed to be characterized prior to sending to Solid Waste for disposal. An assay station consisting of a turntable, HPGe detector, CANBERRA Inspector, transmission source and a portable computer was set up to do the required assays. The assays indicate themore » presence of U-235, Pu-239 and Cs-137. No measurable amounts of U-235 or Pu-239 were found. Therefore the Minimum Detectable Activities for U-235 and Pu-239 were calculated. For Heater Box 1, 0.23 grams of U-235 and 0.24 grams of Pu-239. For Heater Box 2, the results were 0.21 grams of U-235 and 0.21 grams of Pu-239. This paper describes and documents the assays employed to determine the amount of U, Pu and Cs contents of the heater boxes. The paper provides results of SNM assays using traditional calibration of the system and on one based on modeling. It also provides the scientific community with data that will assist the user in determining the method of choice for assaying items with irregular geometries.« less
Silicon Photomultipliers for Compact Neutron Scatter Cameras
NASA Astrophysics Data System (ADS)
Ruch, Marc L.
The ability to locate and identify special nuclear material (SNM) is critical for treaty verification and emergency response applications. SNM is used as the nuclear explosive in a nuclear weapon. This material emits neutrons, either spontaneously or when interrogated. The ability to form an image of the neutron source can be used for characterization and/or to confirm that the item is a weapon by determining whether its shape is consistent with that of a weapon. Additionally, treaty verification and emergency response applications might not be conducive to non-portable instruments. In future weapons treaties, for example, it is unlikely that host countries will make great efforts to facilitate large, bulky, and/or fragile inspection equipment. Furthermore, inspectors and especially emergency responders may need to access locations not easily approachable by vehicles. Therefore, there is a considerable need for a compact, human-portable neutron imaging system. Of the currently available neutron imaging technologies, only neutron scatter cameras (NSCs) can be made truly compact because aperture-based imagers, and time-encoded imagers, rely on large amounts of materials to modulate the neutron signal. NSCs, in contrast, can be made very small because most of the volume of the imager can be filled with active detector material. Also, unlike other neutron imaging technologies, NSCs have the inherent ability to act as neutron spectrometers which gives them an additional means of identifying a neutron source. Until recently, NSCs have relied on photomultiplier tubes (PMT) readouts, which are bulky and fragile, require high voltage, and are very sensitive to magnetic fields. Silicon photomultipliers (SiPMs) do not suffer from these drawbacks and are comparable to PMTs in many respects such as gain, and cost with better time resolution. Historically, SiPMs have been too noisy for these applications; however, recent advancements have greatly reduced this issue and they have now been shown to be viable alternatives to PMTs for neutron detection applications. In this thesis, the development of a handheld NSC based on SiPMs coupled to stilbene bars is presented. An algorithm for performing image reconstruction with this type of device is detailed. Prototype design optimization is achieved using a series of simulations and the construction of the optimized prototype is described. The device is calibrated through a series of collimated measurements, backscatter-gated measurements, and a time-of-flight measurement. Experimental imaging and spectroscopic results are presented for a measurement of a Cf-252 spontaneous fission source. Simulated detector response, based on measurements performed with components of the design, demonstrates that fission sources of different sizes would be distinguishable. Notably, a significant quantity of plutonium can be confidently distinguished from a point neutron source.
Enhanced Analysis Techniques for an Imaging Neutron and Gamma Ray Spectrometer
NASA Astrophysics Data System (ADS)
Madden, Amanda C.
The presence of gamma rays and neutrons is a strong indicator of the presence of Special Nuclear Material (SNM). The imaging Neutron and gamma ray SPECTrometer (NSPECT) developed by the University of New Hampshire and Michigan Aerospace corporation detects the fast neutrons and prompt gamma rays from fissile material, and the gamma rays from radioactive material. The instrument operates as a double scatter device, requiring a neutron or a gamma ray to interact twice in the instrument. While this detection requirement decreases the efficiency of the instrument, it offers superior background rejection and the ability to measure the energy and momentum of the incident particle. These measurements create energy spectra and images of the emitting source for source identification and localization. The dual species instrument provides superior detection than a single species alone. In realistic detection scenarios, few particles are detected from a potential threat due to source shielding, detection at a distance, high background, and weak sources. This contributes to a small signal to noise ratio, and threat detection becomes difficult. To address these difficulties, several enhanced data analysis tools were developed. A Receiver Operating Characteristic Curve (ROC) helps set instrumental alarm thresholds as well as to identify the presence of a source. Analysis of a dual-species ROC curve provides superior detection capabilities. Bayesian analysis helps to detect and identify the presence of a source through model comparisons, and helps create a background corrected count spectra for enhanced spectroscopy. Development of an instrument response using simulations and numerical analyses will help perform spectra and image deconvolution. This thesis will outline the principles of operation of the NSPECT instrument using the double scatter technology, traditional analysis techniques, and enhanced analysis techniques as applied to data from the NSPECT instrument, and an outline of how these techniques can be used to superior detection of radioactive and fissile materials.
Left Handed Materials Based on Magnetic Nanocomposites
2006-10-18
theory that unifies DNMs and SNMs as a function of two flmdamental material parameters: quality factors for permittivity (Qe=e’/e") and permeability (Qu...simultaneously negative effective permeability/uff and permittivity Seff to form LHM or only single negative parameter (SNM) to form negative indexed...developed a theory that unifies DNMs and SNMs as a function of two fundamental material parameters: quality factors for permittivity (Q, = -’/ 6") and
Development of an Integrated Robotic Radioisotope Identification and Location System
2009-05-05
TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of an Integrated Robotic Radioisotope...system within a robotic base in order to inspect an area for either radioisotopes that could be used for a radiological dispersal device (RDD) or are...classified as Special Nuclear Material (SNM). In operation, at a given location in the room, the robot rotates about its circumference searching for
The Efficacy of Denaturing Actinide Elements as a Means of Decreasing Materials Attractiveness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hase, Kevin R.; Ebbinghaus, Bartley B.; Sleaford, Brad W.
2013-07-01
This paper is an extension to earlier studies that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) and alternate nuclear materials (ANM). This study considers the concept of denaturing as applied to the actinide elements present in spent fuel as a means to reduce materials attractiveness. Highly attractive materials generally have low values of bare critical mass, heat content, and dose.
Containment Prospectus for the PIANO Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burkhard, N R
2001-03-23
PIANO is a dynamic, subcritical, zero-yield experiment intended for execution in the U1a.102C drift of the U1a complex at the Nevada Test Site (NTS) (Figure 1). The data from the PIANO experiment will be used in the Stockpile Stewardship Program to assess the aging of nuclear weapon components and to better model the long-term performance of the weapons in the enduring stockpile. The PIANO experiment is composed of one experimental package. The experimental package will have high explosive (HE) and special nuclear material (SNM) in a subcritical assembly. The containment plan for the PIANO series of experiments utilizes a two-containment-vesselmore » concept. The first Containment vessel is formed by the primary containment barrier that seals the U1a.102C drift. The second containment vessel is formed by the secondary containment barrier in the U100 drift. The PIANO experiment is the final experiment to be conducted in the U1a.102C alcove. It will be an ''open'' experiment--meaning that PIANO will not utilize a confinement vessel as the previous OBOE experiments in this alcove did. We expect that the SNM from the PIANO experiment will be fully contained within the first containment vessel.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerr, P. L.
An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements inmore » a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.« less
Programming scheme based optimization of hybrid 4T-2R OxRAM NVSRAM
NASA Astrophysics Data System (ADS)
Majumdar, Swatilekha; Kingra, Sandeep Kaur; Suri, Manan
2017-09-01
In this paper, we present a novel single-cycle programming scheme for 4T-2R NVSRAM, exploiting pulse engineered input signals. OxRAM devices based on 3 nm thick bi-layer active switching oxide and 90 nm CMOS technology node were used for all simulations. The cell design is implemented for real-time non-volatility rather than last-bit, or power-down non-volatility. Detailed analysis of the proposed single-cycle, parallel RRAM device programming scheme is presented in comparison to the two-cycle sequential RRAM programming used for similar 4T-2R NVSRAM bit-cells. The proposed single-cycle programming scheme coupled with the 4T-2R architecture leads to several benefits such as- possibility of unconventional transistor sizing, 50% lower latency, 20% improvement in SNM and ∼20× reduced energy requirements, when compared against two-cycle programming approach.
Liquefied Noble Gas (LNG) detectors for detection of nuclear materials
NASA Astrophysics Data System (ADS)
Nikkel, J. A.; Gozani, T.; Brown, C.; Kwong, J.; McKinsey, D. N.; Shin, Y.; Kane, S.; Gary, C.; Firestone, M.
2012-03-01
Liquefied-noble-gas (LNG) detectors offer, in principle, very good energy resolution for both neutrons and gamma rays, fast response time (hence high-count-rate capabilities), excellent discrimination between neutrons and gamma rays, and scalability to large volumes. They do, however, need cryogenics. LNG detectors in sizes of interest for fissionable material detection in cargo are reaching a certain level of maturity because of the ongoing extensive R&}D effort in high-energy physics regarding their use in the search for dark matter and neutrinoless double beta decay. The unique properties of LNG detectors, especially those using Liquid Argon (LAr) and Liquid Xenon (LXe), call for a study to determine their suitability for Non-Intrusive Inspection (NII) for Special Nuclear Materials (SNM) and possibly for other threats in cargo. Rapiscan Systems Laboratory, Yale University Physics Department, and Adelphi Technology are collaborating in the investigation of the suitability of LAr as a scintillation material for large size inspection systems for air and maritime containers and trucks. This program studies their suitability for NII, determines their potential uses, determines what improvements in performance they offer and recommends changes to their design to further enhance their suitability. An existing 3.1 liter LAr detector (microCLEAN) at Yale University, developed for R&}D on the detection of weakly interacting massive particles (WIMPs) was employed for testing. A larger version of this detector (15 liters), more suitable for the detection of higher energy gamma rays and neutrons is being built for experimental evaluation. Results of measurements and simulations of gamma ray and neutron detection in microCLEAN and a larger detector (326 liter CL38) are presented.
NRF Based Nondestructive Inspection System for SNM by Using Laser-Compton-Backscattering Gamma-Rays
NASA Astrophysics Data System (ADS)
Ohgaki, H.; Omer, M.; Negm, H.; Daito, I.; Zen, H.; Kii, T.; Masuda, K.; Hori, T.; Hajima, R.; Hayakawa, T.; Shizuma, T.; Kando, M.
2015-10-01
A non-destructive inspection system for special nuclear materials (SNMs) hidden in a sea cargo has been developed. The system consists of a fast screening system using neutron generated by inertial electrostatic confinement (IEC) device and an isotope identification system using nuclear resonance fluorescence (NRF) measurements with laser Compton backscattering (LCS) gamma-rays has been developed. The neutron flux of 108 n/sec has been achieved by the IEC in static mode. We have developed a modified neutron reactor noise analysis method to detect fission neutron in a short time. The LCS gamma-rays has been generated by using a small racetrack microtoron accelerator and an intense sub-nano second laser colliding head-on to the electron beam. The gamma-ray flux has been achieved more than 105 photons/s. The NRF gamma-rays will be measured using LaBr3(Ce) scintillation detector array whose performance has been measured by NRF experiment of U-235 in HIGS facility. The whole inspection system has been designed to satisfy a demand from the sea port.
NASA Astrophysics Data System (ADS)
Brown, C.; Gozani, T.; Shaw, T.; Stevenson, J.
2011-10-01
In the search for concealed special nuclear materials (SNM) there are a number of fission specific signatures that can be measured. These include prompt and delayed neutron and gamma ray signatures. Here the focus will be on the delayed gamma signature with the assumption that a pulsed electron linac with a constant peak current will be used to generate bremsstrahlung radiation and induce photofission in 235U. In this case, the signal to background ratio (S/B) will depend on the choice of linac frequency, pulse mode, and "active" background due to linac activation products. The linac frequency is simply the rate at which it produces short bursts of radiation, typically 2-4 μs in duration. There are two pulse modes, micro-pulsing, and macro-pulsing. In the micro-pulsing mode, the linac runs continuously at its set frequency and data is collected between bursts. In the macro-pulsing mode, the linac is turned on for a given length of time, on the order of seconds, and then turned off for a period of time typically equal to the length of time it was turned on. Counting takes place during the time the linac is off and stops when the linac is turned on for another cycle. The time dependence of the delayed gamma population can be approximated by the use of 5 time groups with half-lives of 0.29, 1.7, 13, 100, and 940 s, respectively. Each group has its own relative population, which together with its half-life determines what time frame the group contributes most to the measured signal. For example, a group with a short half-life will contribute more signal to a short cycle macro pulsed measurement than it would to a macro pulse measurement with a very long cycle. An analytical expression can be derived that calculates the maximum obtainable signal (delayed gamma photons per fission gamma ray) in either a micro- or macro-pulsed measurement. Using this information along with the observed active background present in a given situation (which can constrain the micro-pulsing parameters), the preferred mode of operation can be chosen to maximize S/B and the detection sensitivity. The principles and experimental application of the optimization process will be shown.
Development of a Dual-Particle Imaging System for Nonproliferation Applications
NASA Astrophysics Data System (ADS)
Poitrasson-Riviere, Alexis Pierre Valere
A rising concern in our society is preventing the proliferation of nuclear weapons and fissionable material. This prevention can be incorporated at multiple levels, from the use of nuclear safeguards in nuclear facilities to the detection of threat objects in the field. At any level, systems used for such tasks need to be specially designed for use with Special Nuclear Material (SNM) which is defined by the NRC as plutonium and uranium enriched in U-233 or U-235 isotopes. These radioactive materials have the particularity of emitting both fast neutrons and gamma rays; thus, systems able to detect both particles simultaneously are particularly desirable. In the field of nuclear nonproliferation and safeguards, detection systems capable of accurately imaging various sources of radiation can greatly simplify any monitoring or detection task. The localization of the radiation sources can allow users of the system to focus their efforts on the areas of interest, whether it be for radiation detection or radiation characterization. This thesis describes the development of a dual-particle imaging system at the University of Michigan to address these technical challenges. The imaging system relies on the use of organic liquid scintillators that can detect both fast neutrons and gamma rays, and inorganic NaI(Tl) scintillators that are not very sensitive to neutrons yet yield photoelectric absorptions from gamma rays. A prototype of the imaging system has been constructed and operated. The system will aid the remote monitoring of nuclear materials within facilities, and it has the scalability for standoff detection in the field. A software suite has been developed to analyze measured data in real time, in an effort to obtain a system as close to field-ready as possible. The system's performance has been tested with various materials of interest, such as MOX and plutonium metal, measured at the PERLA facility of the Joint Research Center in Ispra, Italy. The robust and versatile imaging system is an attractive alternative to the current imaging systems.
2006-06-01
response (time domain) structural vibration model for mistuned rotor bladed disk based on the efficient SNM model has been developed. The vi- bration...airfoil and 3D wing, unsteady vortex shedding of a stationary cylinder, induced vibration of a cylinder, forced vibration of a pitching airfoil, induced... vibration and flutter boundary of 2D NACA 64A010 transonic airfoil, 3D plate wing structural response. The predicted results agree well with benchmark
Holdup measurement for nuclear fuel manufacturing plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zucker, M.S.; Degen, M.; Cohen, I.
1981-07-13
The assay of nuclear material holdup in fuel manufacturing plants is a laborious but often necessary part of completing the material balance. A range of instruments, standards, and a methodology for assaying holdup has been developed. The objectives of holdup measurement are ascertaining the amount, distribution, and how firmly fixed the SNM is. The purposes are reconciliation of material unbalance during or after a manufacturing campaign or plant decommissioning, to decide security requirements, or whether further recovery efforts are justified.
McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.
2010-12-21
Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skrodzki, P. J.; Becker, J. R.; Diwakar, P. K.
Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics which require rapid analysis, minimal sample preparation and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates U signal in a glass matrix using DPLIBS and compares to signal features obtained using SPLIBS. DPLIBS involves sequential firing of 1.06 µm Nd:YAG pre-pulse and 10.6 µm TEA CO2 heating pulsemore » in near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines and signals for bulk analyte Ca and minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with negligible further damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to observed U analyte signal variation between SPLIBS and DPLIBS.« less
1993-09-01
DOCUMENTATION PAGE M N Public mpsMIs b~ b•r tOr coleton of ia nlormmn ias edsimad to aevue 1 hour pw response , indudng the Snm ta raing e. taeu"tig aining...Asbestos Emergency Response Act of 1986 (AHERA), which mandates inspection in school grades Kindergarten through 12. Congress is currently...CRC), Georgia Institute of Technology, Atlanta, GA. The CRC was responsible for the technical portion of the research program; i.e., developing the test
1994-03-01
AND THE 7.X 4 C12’r RIGE PA SBOON PER NSONS OF BOX AND HAVINM BIYENSI1ON OF 17-AND2 LONG BY 11-1/2" WIDE BY 8-14’" HIOP, MRE SN)M. MAIMUM LADO WEIGHT O...INSTALL EACH STRAP FROM A TIEDOWN ANCHOR ON SIDE OF FATRACK, AROUND ENC OF PALLET AT EACH LOCATION SHOWN. TO A TI MWN ACHOR ON THE OPPOSITE SIDE OF
Nuclear Weapons Materials Gone Missing: What Does History Teach?
2014-11-01
ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army War...Strategic Studies Institute of the U.S. Army War College. The volume features re- search done over the last 2 years. Funding for this project came from the...Cochran: The statistical distribution of MUF will have a given one- sigma and two- sigma range. A MUF of zero does not mean that SNM [special nuclear
Radiation Detection for Homeland Security Applications
NASA Astrophysics Data System (ADS)
Ely, James
2008-05-01
In the past twenty years or so, there have been significant changes in the strategy and applications for homeland security. Recently there have been significant at deterring and interdicting terrorists and associated organizations. This is a shift in the normal paradigm of deterrence and surveillance of a nation and the `conventional' methods of warfare to the `unconventional' means that terrorist organizations resort to. With that shift comes the responsibility to monitor international borders for weapons of mass destruction, including radiological weapons. As a result, countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders. These efforts include deployments at land, rail, air, and sea ports of entry in the US and in European and Asian countries. Radioactive signatures of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. This talk will present an overview of radiation detection equipment with emphasis on radiation portal monitors. In the US, the deployment of radiation detection equipment is being coordinated by the Domestic Nuclear Detection Office within the Department of Homeland Security, and a brief summary of the program will be covered. Challenges with current generation systems will be discussed as well as areas of investigation and opportunities for improvements. The next generation of radiation portal monitors is being produced under the Advanced Spectroscopic Portal program and will be available for deployment in the near future. Additional technologies, from commercially available to experimental, that provide additional information for radiation screening, such as density imaging equipment, will be reviewed. Opportunities for further research and development to improve the current equipment and methodologies for radiation detection for the important task of homeland security will be the final topic to be discussed.
NASA Astrophysics Data System (ADS)
King, Michael Joseph
Instrumentation development is essential to the advancement and success of homeland security systems. Active interrogation techniques that scan luggage and cargo containers for shielded special nuclear materials or explosives hold great potential in halting further terrorist attacks. The development of more economical, compact and efficient source and radiation detection devices will facilitate scanning of all containers and luggage while maintaining high-throughput and low-false alarms Innovative ion sources were developed for two novel, specialized neutron generating devices and initial generator tests were performed. In addition, a low-energy acceleration gamma generator was developed and its performance characterized. Finally, an organic semiconductor was investigated for direct fast neutron detection. A main part of the thesis work was the development of ion sources, crucial components of the neutron/gamma generator development. The use of an externally-driven radio-frequency antenna allows the ion source to generate high beam currents with high, mono-atomic species fractions while maintaining low operating pressures, advantageous parameters for neutron generators. A dual "S" shaped induction antenna was developed to satisfy the high current and large extraction area requirements of the high-intensity neutron generator. The dual antenna arrangement generated a suitable current density of 28 mA/cm2 at practical RF power levels. The stringent requirements of the Pulsed Fast Neutron Transmission Spectroscopy neutron generator necessitated the development of a specialized ten window ion source of toroidal shape with a narrow neutron production target at its center. An innovative ten antenna arrangement with parallel capacitors was developed for driving the multi-antenna arrangement and uniform coupling of RF power to all ten antennas was achieved. To address the desire for low-impact, low-radiation dose active interrogation systems, research was performed on mono-energetic gamma generators that operate at low-acceleration energies and leverage neutron generator technologies. The dissertation focused on the experimental characterization of the generator performance and involved MCNPX simulations to evaluate and analyze the experimental results. The emission of the 11.7 MeV gamma-rays was observed to be slightly anisotropic and the gamma yield was measured to be 2.0*105 gamma/s-mA. The lanthanum hexaboride target suffered beam damage from a high power density beam; however, this may be overcome by sweeping the beam across a larger target area. The efficient detection of fast neutrons is vital to active interrogation techniques for the detection of both SNM and explosives. Novel organic semiconductors are air-stable, low-cost materials that demonstrate direct electronic particle detection. As part of the development of a pi-conjugated organic polymer for fast neutron detection, charge generation and collection properties were investigated. By devising a dual, thin-film detector test arrangement, charge collection was measured for high energy protons traversing the dual detector arrangement that allowed the creation of variable track lengths by tilting the detector. The results demonstrated that an increase in track length resulted in a decreased signal collection. This can be understood by assuming charge carrier transport along the track instead of along the field lines, which was made possible by the filling of traps. However, this charge collection mechanism may be insufficient to generate a useful signal. This dissertation has explored the viability of a new generation of radiation sources and detectors, where the newly developed ion source technologies and prototype generators will further enhance the capabilities of existing threat detection systems and promote the development of cutting-edge detection technologies.
NBS1 Phosphorylation Status Dictates Repair Choice of Dysfunctional Telomeres.
Rai, Rekha; Hu, Chunyi; Broton, Cayla; Chen, Yong; Lei, Ming; Chang, Sandy
2017-03-02
Telomeres employ TRF2 to protect chromosome ends from activating the DNA damage sensor MRE11-RAD50-NBS1 (MRN), thereby repressing ATM-dependent DNA damage checkpoint responses. How TRF2 prevents MRN activation at dysfunctional telomeres is unclear. Here, we show that the phosphorylation status of NBS1 determines the repair pathway choice of dysfunctional telomeres. The crystal structure of the TRF2-NBS1 complex at 3.0 Å resolution shows that the NBS1 429 YQLSP 433 motif interacts specifically with the TRF2 TRFH domain. Phosphorylation of NBS1 serine 432 by CDK2 in S/G2 dissociates NBS1 from TRF2, promoting TRF2-Apollo/SNM1B complex formation and the protection of leading-strand telomeres. Classical-NHEJ-mediated repair of telomeres lacking TRF2 requires phosphorylated NBS1 S432 to activate ATM, while interaction of de-phosphorylated NBS1 S432 with TRF2 promotes alternative-NHEJ repair of telomeres lacking POT1-TPP1. Our work advances understanding of how the TRF2 TRFH domain orchestrates telomere end protection and reveals how the phosphorylation status of the NBS1 S432 dictates repair pathway choice of dysfunctional telomeres. Copyright © 2017 Elsevier Inc. All rights reserved.
Aspinall, Tanya V; Gordon, James M B; Bennett, Hayley J; Karahalios, Panagiotis; Bukowski, John-Paul; Walker, Scott C; Engelke, David R; Avis, Johanna M
2007-01-01
Ribonuclease MRP is an endonuclease, related to RNase P, which functions in eukaryotic pre-rRNA processing. In Saccharomyces cerevisiae, RNase MRP comprises an RNA subunit and ten proteins. To improve our understanding of subunit roles and enzyme architecture, we have examined protein-protein and protein-RNA interactions in vitro, complementing existing yeast two-hybrid data. In total, 31 direct protein-protein interactions were identified, each protein interacting with at least three others. Furthermore, seven proteins self-interact, four strongly, pointing to subunit multiplicity in the holoenzyme. Six protein subunits interact directly with MRP RNA and four with pre-rRNA. A comparative analysis with existing data for the yeast and human RNase P/MRP systems enables confident identification of Pop1p, Pop4p and Rpp1p as subunits that lie at the enzyme core, with probable addition of Pop5p and Pop3p. Rmp1p is confirmed as an integral subunit, presumably associating preferentially with RNase MRP, rather than RNase P, via interactions with Snm1p and MRP RNA. Snm1p and Rmp1p may act together to assist enzyme specificity, though roles in substrate binding are also indicated for Pop4p and Pop6p. The results provide further evidence of a conserved eukaryotic RNase P/MRP architecture and provide a strong basis for studies of enzyme assembly and subunit function.
Termination of Safeguards for Accountable Nuclear Materials at the Idaho National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael Holzemer; Alan Carvo
2012-04-01
Termination of safeguards ends requirements of Nuclear Material Control and Accountability (MC&A) and thereby removes the safeguards basis for applying physical protection requirements for theft and diversion of nuclear material, providing termination requirements are met as described. Department of Energy (DOE) M 470.4 6 (Nuclear Material Control and Accountability [8/26/05]) stipulates: 1. Section A, Chapter I (1)( q) (1): Safeguards can be terminated on nuclear materials provided the following conditions are met: (a) 'If the material is special nuclear material (SNM) or protected as SNM, it must be attractiveness level E and have a measured value.' (b) 'The material hasmore » been determined by DOE line management to be of no programmatic value to DOE.' (c) 'The material is transferred to the control of a waste management organization where the material is accounted for and protected in accordance with waste management regulations. The material must not be collocated with other accountable nuclear materials.' Requirements for safeguards termination depend on the safeguards attractiveness levels of the material. For attractiveness level E, approval has been granted from the DOE Idaho Operations Office (DOE ID) to Battelle Energy Alliance, LLC (BEA) Safeguards and Security (S&S). In some cases, it may be necessary to dispose of nuclear materials of attractiveness level D or higher. Termination of safeguards for such materials must be approved by the Departmental Element (this is the DOE Headquarters Office of Nuclear Energy) after consultation with the Office of Security.« less
The Apollo 5' exonuclease functions together with TRF2 to protect telomeres from DNA repair.
Lenain, Christelle; Bauwens, Serge; Amiard, Simon; Brunori, Michele; Giraud-Panis, Marie-Josèphe; Gilson, Eric
2006-07-11
A major issue in telomere research is to understand how the integrity of chromosome ends is preserved . The human telomeric protein TRF2 coordinates several pathways that prevent checkpoint activation and chromosome fusions. In this work, we identified hSNM1B, here named Apollo, as a novel TRF2-interacting factor. Interestingly, the N-terminal domain of Apollo is closely related to that of Artemis, a factor involved in V(D)J recombination and DNA repair. Both proteins belong to the beta-CASP metallo-beta-lactamase family of DNA caretaker proteins. Apollo appears preferentially localized at telomeres in a TRF2-dependent manner. Reduced levels of Apollo exacerbate the sensitivity of cells to TRF2 inhibition, resulting in severe growth defects and an increased number of telomere-induced DNA-damage foci and telomere fusions. Purified Apollo protein exhibits a 5'-to-3' DNA exonuclease activity. We conclude that Apollo is a novel component of the human telomeric complex and works together with TRF2 to protect chromosome termini from being recognized and processed as DNA damage. These findings unveil a previously undescribed telomere-protection mechanism involving a DNA 5'-to-3' exonuclease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, C. G.; Wallace, R. K.; Ireland, J. R.
2010-09-01
This paper is an extension to earlier studies1,2 that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) and alternate nuclear materials (ANM) associated with the PUREX, UREX, COEX, THOREX, and PYROX reprocessing schemes. This study extends the figure of merit (FOM) for evaluating attractiveness to cover a broad range of proliferant state and sub-national group capabilities. The primary conclusion of this study is that all fissile material needs to be rigorously safeguarded to detect diversion by a state and provided the highest levels of physical protection to prevent theft by sub-national groups; no “silver bullet” has beenmore » found that will permit the relaxation of current international safeguards or national physical security protection levels. This series of studies has been performed at the request of the United States Department of Energy (DOE) and is based on the calculation of "attractiveness levels" that are expressed in terms consistent with, but normally reserved for nuclear materials in DOE nuclear facilities.3 The expanded methodology and updated findings are presented. Additionally, how these attractiveness levels relate to proliferation resistance and physical security are discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, Charles G; Wallace, Richard K; Ireland, John R
2009-01-01
This paper is an extension to earlier studies that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) and alternate nuclear materials (ANM) associated with the PUREX, UREX, COEX, THOREX, and PYROX reprocessing schemes. This study extends the figure of merit (FOM) for evaluating attractiveness to cover a broad range of proliferant state and sub-national group capabilities. The primary conclusion of this study is that all fissile material needs to be rigorously safeguarded to detect diversion by a state and provided the highest levels of physical protection to prevent theft by sub-national groups; no 'silver bullet' has beenmore » found that will permit the relaxation of current international safeguards or national physical security protection levels. This series of studies has been performed at the request of the United States Department of Energy (DOE) and is based on the calculation of 'attractiveness levels' that are expressed in terms consistent with, but normally reserved for nuclear materials in DOE nuclear facilities. The expanded methodology and updated findings are presented. Additionally, how these attractiveness levels relate to proliferation resistance and physical security are discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moak, Don J.; Grondin, Richard L.; Triner, Glen C.
CH2M Hill Plateau Remediation Company (CHRPC) is a prime contractor to the U.S. Department of Energy (DOE) focused on the largest ongoing environmental remediation project in the world at the DOE Hanford Site Central Plateau, i.e. the DOE Hanford Plateau Remediation Contract. The East Tennessee Materials and Energy Corporation (M and EC); a wholly owned subsidiary of Perma-Fix Environmental Services, Inc. (PESI), is a small business team member to CHPRC. Our scope includes project management; operation and maintenance of on-site storage, repackaging, treatment, and disposal facilities; and on-site waste management including waste receipt from generators and delivery to on-site andmore » off-site treatment, storage, and disposal facilities. As part of this scope, M and EC staffs the centralized Waste Support Services organization responsible for all waste characterization and acceptance required to support CHPRC and waste generators across the Hanford Site. At the time of the CHPRC contract award (August 2008) slightly more than 9,000 cubic meters (m{sup 3}) of legacy waste was defined as 'no-path-forward waste'. A significant portion of this waste (7,650 m{sup 3}) comprised wastes with up to 50 grams of special nuclear materials (SNM) in oversized packages recovered during retrieval operations and large glove boxes removed from the Plutonium Finishing Plant (PFP). Through a collaborative effort between the DOE, CHPRC, and Perma-Fix Environmental Services, Inc. (PESI), pathways for these problematic wastes were developed that took advantage of commercial treatment capabilities at a nearby vendor facility, Perma-Fix Northwest (PFNW). In the spring of 2009, CHPRC initiated a pilot program under which they began shipping large package, low gram suspect TRU (<15 g SNM per container), and large package contact and remote handled MLLW to the off-site PFNW facility for treatment. PFNW is restricted by the SNM limits set for the total quantity of SNM allowed at the facility in accordance with the facility's radioactive materials license(s) (RML). While both CHPRC and PFNW maintain waste databases to track all waste movements, it became evident early in the process that a tool was needed that married the two systems to better track SNM inventories and sequence waste from the point of generation, through the PFNW facility, and back to the Hanford site for final disposition. This tool, known as the Treatment Integration and Planning Tool (TIPT), has become a robust planning tool that provides real-time data to support compliant and efficient waste generation, transportation, treatment, and disposition. TIPT is developing into the next generation tool that will change the way in which legacy wastes, retrieval wastes and decontamination and decommissioning operations are conducted on the Plateau Remediation Contract (PRC). The real value of the TIPT is its predictive capability. It allows the W and FMP to map out optimal windows for processing waste through the PFNW facility, or through any process that is in some way resource limited. It allows project managers to identify and focus on problem areas before shipments are affected. It has been modified for use in broader applications to predict turnaround times and identify windows of opportunity for processing higher gram wastes through PFNW and to allow waste generators, site-wide, to accurately predict scope, cost, and schedule for waste generation to optimize processing and eliminate storage, double handling, and related costs and unnecessary safety risks. The TIPT addresses the years old problem of how to effectively predict not only what needs to be done, but when. 'When' is the key planning parameter that has been ignored by the generator and processor for many years, but has proven to be the most important parameter for both parties. While further refinement is a natural part of any development process, the current improvements on the TIPT have shown that prediction is a powerful consideration. Even in lean times expected for the foreseeable future, the improved TIPT continues to play a central role in managing our way through those times to assure facilities remain viable and available. It is recommended that other major remediation projects and waste processing facilities incorporate a tool such as TIPT to improve customer-commercial supplier communications and better optimization of resources. (authors)« less
2009-03-01
the research objectives for this study are presented. It should be noted that sensor cost was not considered for this study. Additionally, further...development costs ) for gravity compensation require- ments of its trident submarine inertial navigation systems and by the Air Force Geo- physics...52]: T (r, φ, λ) = GM ae Nmax∑ n=2 n∑ m=0 (a r )n+1 (Cnm cosmλ+ Snm sinmλ)P nm(cos φ) (31) 44 where r, φ, λ are the geocentric distance, lattitude and
Application and Development of Microstructured Solid-State Neutron Detectors
NASA Astrophysics Data System (ADS)
Weltz, Adam D.
Neutron detectors are useful for a number of applications, including the identification of nuclear weapons, radiation dosimetry, and nuclear reactor monitoring, among others. Microstructured solid-state neutron detectors (SSNDs) developed at RPI have the potential to reinvent a variety of neutron detection systems due to their compact size, zero bias requirement, competitive thermal neutron detection efficiency (up to 29%), low gamma sensitivity (below the PNNL recommendation of 10-6 corresponding to a 10 mR/hr gamma exposure), and scalability to large surface areas with a single preamplifier (<20% loss in relative efficiency from 1 to 16 cm2). These microstructured SSNDs have semiconducting substrate etched with a repeated, three-dimensional microstructure of high aspect ratio holes filled with 10B. MCNP simulations optimized the dimensions of each microstructure geometry for each detector application, improving the overall performance. This thesis outlines the development of multiple, novel neutron detection applications using microstructured SSNDs developed at RPI. The Directional and Spectral Neutron Detection System (DSNDS) is a modular and portable system that uses rings of microstructured SSNDs embedded in polyethylene in order to gather real-time information about the directionality and spectrum of an unidentified neutron source. This system can be used to identify the presence of diverted special nuclear material (SNM), determine its position, and gather spectral information in real-time. The compact and scalable zero-bias SSNDs allow for customization and modularity of the detector array, which provides design flexibility and enhanced portability. Additionally, a real-time personal neutron dosimeter is a wearable device that uses a combination of fast and thermal microstructured SSNDs in order to determine an individual's neutron dose rate. This system demonstrates that neutron detection systems utilizing microstructured SSNDs are applicable for personal neutron dosimetry. The development of these systems using the compact, zero-bias microstructured SSNDs lays the groundwork for a new generation of neutron detection tools, outlines the challenges and design considerations associated with the implementation of these devices, and demonstrates the value that these detectors bring to the future of neutron detection systems.
NASA Astrophysics Data System (ADS)
Streicher, Michael; Brown, Steven; Zhu, Yuefeng; Goodman, David; He, Zhong
2016-10-01
To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.
Long-term follow-up of sacral neuromodulation for lower urinary tract dysfunction.
Peeters, Karlien; Sahai, Arun; De Ridder, Dirk; Van Der Aa, Frank
2014-05-01
To report our long-term experience of sacral neuromodulation (SNM) for various lower urinary tract dysfunctions but with a focus on efficacy, safety, re-interventions and degree of success. This is a single tertiary referral centre study that included 217 patients (86% female) who received an implantable pulse generator (IPG) (Interstim™, Medtronic, Minneapolis, USA) between 1996 and 2010. Success was considered if the initial ≥50% improvement in any of primary voiding diary variables persisted compared with baseline, but was further stratified. The mean duration of follow-up was 46.88 months. Success and cure rates were ≈70% and 20% for urgency incontinence, 68% and 33% for urgency frequency syndrome and 73% and 58% for idiopathic retention. In those patients with an unsuccessful therapy outcome, the mean time to failure was 24.6 months after implantation. There were 88 (41%) patients who had at least one device or treatment related surgical re-intervention. The re-intervention rate was 1.7 per patient with most of them (47%) occurring ≤2 years of follow-up. SNM appears effective in the long-term with a success rate after definitive IPG implant of ≈70% and complete cure rates ranging between 20% and 58% depending on indication. Patients with idiopathic retention appear to do best. The re-intervention rate is high with most occurring ≤2 years of implantation. It is likely that with the newer techniques used, efficacy and re-intervention rates will improve. © 2013 The Authors. BJU International © 2013 BJU International.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azmy, Yousry; Cacuci, Dan
In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantitymore » and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use Bayes’ Theorem, one must have a model y(x) that maps the state variables x (the solution in this case) to the measurements y. In this case, the unknown state variables are the configuration and composition of the heldup SNM. The measurements are the detector readings. Thus, the natural model is neutral-particle radiation transport where a wealth of computational tools exists for performing these simulations accurately and efficiently. The combination of predictive model and Bayesian inference forms the Data Integration with Modeled Predictions (DIMP) method that serves as foundation for this project. The cost functional describing the model-to-data misfit is computed via a norm created by the inverse of the covariance matrix of the model parameters and responses. Since the model y(x) for the holdup problem is nonlinear, a nonlinear optimization on Q is conducted via Newton-type iterative methods to find the optimal values of the model parameters x. This project comprised a collaboration between NC State University (NCSU), the University of South Carolina (USC), and Oak Ridge National Laboratory (ORNL). The project was originally proposed in seven main tasks with an eighth contingency task to be performed if time and funding permitted; in fact time did not permit commencement of the contingency task and it was not performed. The remaining tasks involved holdup analysis with gamma detection strategies and separately with neutrons based on coincidence counting. Early in the project, and upon consultation with experts in coincidence counting it became evident that this approach is not viable for holdup applications and this task was replaced with an alternative, but valuable investigation that was carried out by the USC partner. Nevertheless, the experimental 4 measurements at ORNL of both gamma and neutron sources for the purpose of constructing Detector Response Functions (DRFs) with the associated uncertainties were indeed completed.« less
2006-08-01
64Cu -Labeled Abegrin™, a Humanized Monoclonal Antibody against Integrin αvβ3 Cancer Res. 2006;66(19):9673-81. 11. Hsu AR, Hou LC, Veeravagu A...FL, March, 2006. 5. Wu Y, Cai W, Zhang X, Chen K, Cao Q, Tice D, Chen X. In Vitro and In Vivo Characterization of 64Cu -Labeled Vitaxin, a...53rd SNM Annual meeting, San Diego, CA, June 2006 9. Cai W, Wu Y, Cao Q, Chen K, Zhang X, Tice D, Chen X 64Cu -Labeled Humanized Anti
Ultra-Low-Energy Sub-Threshold Circuits: Program Overview
2007-04-10
with global > 0.1 corner, but so does VUL, VIH 0 .0 5 -_ "or ni n a Global Variatlion 0.0a 0•,lN& 0.24.. 7 Mir" Output Swing Metrics " Need a... VIH . lines plot the VTCs when random local VT mismatch is ap- In Figure 1(b), a NAND gate has sufficient output swing plied to the inverter. One case...the VTC is input-dependent, all inputs are varied simultaneously to >P 1 0 SNM side of largest obtain the worst case ViH and VIL. > 0 ins0nbedsquare
NASA Astrophysics Data System (ADS)
Kerebel, A.; Cassidy, R.; Jordan, P.; Holden, N. M.
2012-04-01
Eutrophication of both fresh and coastal water bodies is one of the greatest threats to water quality in Europe and other developed countries. Sources of pollution are multiple but agriculture is known to be a large contributor, due to farm nutrient management such as land spreading of fertilisers and their subsequent loss via overland flow to surface waters. The stringent targets set for compliance with the Water Framework Directive by 2015 have led to action by the Irish regulatory authorities to reduce risk and prevent further deterioration of water status. One step was to prohibit the spreading of fertilisers over the winter period, with closed periods in 3 zones based on annual rainfall statistics. While this calendar approach is supported by scientific evidence, its justification has been debated by the farming community. A consequence of the regulation has been the concentration of hazard on dates directly preceding and following the closed period when soils can be heavily loaded with organic slurries and manures. An alternative lies in a Sustainable Nutrient Management Decision Support System (SNM-DSS), which has been developed to predict optimum conditions for fertiliser application depending on real-time observations of soil and weather conditions. The Hybrid Soil Moisture Deficit (HSMD) model forms the basis of this system and is essential for defining the thresholds for optimum management. The model outputs were tested against field water content data (θ) and evaluated by comparison with farmer opinion over a 3-year period. Daily Soil Moisture Deficit (SMD) was calculated from weather data collected on 5 sites and θ was estimated using time domain Reflectometry probes on 10 fields (2 × 5 sites). The question "Can slurry be spread today?" was also answered on a daily basis by 6 farmers located at the instrumented sites and the responses were related to calculated SMD values. A significant relationship between SMD and θ for all test sites showed that the HSMD model acceptably captured temporal variations in θ, suggesting that it should be able to predict when risk of nutrient transport by gravity moveable water is high. It was also found that the decision whether to spread the nutrients was determined by soil moisture conditions relative to field capacity. According to farmer opinion, slurry should not be spread when the soil is at or wetter than field capacity but conditions would be suitable when drier. The HSMD model showed great potential and could therefore be used as a core component in a decision support tool for daily farm management practices such as slurry spreading. Although the SNM-DSS has been designed to work at the farm scale, such tools should be able to devise sustainable nutrient management plans for agricultural catchments.
A unifying model of concurrent spatial and temporal modularity in muscle activity.
Delis, Ioannis; Panzeri, Stefano; Pozzo, Thierry; Berret, Bastien
2014-02-01
Modularity in the central nervous system (CNS), i.e., the brain capability to generate a wide repertoire of movements by combining a small number of building blocks ("modules"), is thought to underlie the control of movement. Numerous studies reported evidence for such a modular organization by identifying invariant muscle activation patterns across various tasks. However, previous studies relied on decompositions differing in both the nature and dimensionality of the identified modules. Here, we derive a single framework that encompasses all influential models of muscle activation modularity. We introduce a new model (named space-by-time decomposition) that factorizes muscle activations into concurrent spatial and temporal modules. To infer these modules, we develop an algorithm, referred to as sample-based nonnegative matrix trifactorization (sNM3F). We test the space-by-time decomposition on a comprehensive electromyographic dataset recorded during execution of arm pointing movements and show that it provides a low-dimensional yet accurate, highly flexible and task-relevant representation of muscle patterns. The extracted modules have a well characterized functional meaning and implement an efficient trade-off between replication of the original muscle patterns and task discriminability. Furthermore, they are compatible with the modules extracted from existing models, such as synchronous synergies and temporal primitives, and generalize time-varying synergies. Our results indicate the effectiveness of a simultaneous but separate condensation of spatial and temporal dimensions of muscle patterns. The space-by-time decomposition accommodates a unified view of the hierarchical mapping from task parameters to coordinated muscle activations, which could be employed as a reference framework for studying compositional motor control.
Liu, Fan; Cottrell, Jeremy James; Collins, Cherie Louise; Henman, David James; O'Halloran, Kirrily Sharon Beatrice; Dunshea, Frank Rowland
2017-10-01
Heat stress (HS) exacerbates the body weight loss of lactating sows and reduces litter weight gain. Selenium (Se), vitamin E (VE), chromium (Cr) and betaine have been shown to ameliorate symptoms of HS, and yeast nucleotides and mannan oligosaccharides have been reported to improve lactational performance and immune response in pigs. Therefore, a combination of these nutrients may improve lactational performance of sows in summer. The effects of two nutritionally enhanced diets on lactational performance of sows in summer were investigated in two experiments. In experiment 1, we compared the effects of a nutritionally fortified diet (0.4 ppm Se, 95 IU/kg VE, 0.4 ppm Cr and 0.2% betaine; named as SVCB diet) with the NRC 2012 standard diet (0.15 ppm Se, 44 IU/kg VE) on lactational performance of sows in summer. Results showed that the SVCB diet reduced body weight loss (P = 0.039) and tended to reduce backfat loss (P = 0.075) of sows without affecting feed intake, while litter weight gain was not influenced. In experiment 2, we further enhanced the nutrients in the SVCB diet (0.8 ppm Se, 1% yeast nucleotides, and 0.1% mannan oligosaccharides; named as SNM diet). Results showed that the SNM diet did not improve feed intake of sows, farrowing performance, or litter weight gain compared with the SVCB diet, but increased body weight loss of the third parity sows (P = 0.037). Overall, a combined supplementation of Se, VE, Cr, and betaine above the NRC recommended levels can reduce mobilisation of body reserve of lactating sows in summer.
NASA Astrophysics Data System (ADS)
Seo, Youngsoo; Kim, Shinkeun; Ko, Kyul; Woo, Changbeom; Kim, Minsoo; Lee, Jangkyu; Kang, Myounggon; Shin, Hyungcheol
2018-02-01
In this paper, electrical characteristics of gate-all-around (GAA) nanoplate (NP) vertical FET (VFET) were analyzed for single transistor and 6T-SRAM cell through 3D technology computer-aided design (TCAD) simulation. In VFET, gate and extension lengths are not limited by the area of device because theses lengths are vertically located. The height of NP is assumed in 40 nm considering device fabrication method (top-down approach). According to the sizes of devices, we analyzed the performances of device such as total resistance, capacitance, intrinsic gate delay, sub-threshold swing (S.S), drain-induced barrier lowering (DIBL) and static noise margin (SNM). As the gate length becomes larger, the resistance should be smaller because the total height of NP is fixed in 40 nm. Also, when the channel thickness becomes thicker, the total resistance becomes smaller since the sheet resistances of channel and extension become smaller and the contact resistance becomes smaller due to the increasing contact area. In addition, as the length of channel pitch increases, the parasitic capacitance comes to be larger due to the increasing area of gate-drain and gate-source. The performance of RC delay is best in the shortest gate length (12 nm), the thickest channel (6 nm) and the shortest channel pitch (17 nm) owing to the reduced resistance and parasitic capacitance. However, the other performances such as DIBL, S.S, on/off ratio and SNM are worst because the short channel effect is highest in this situation. Also, we investigated the performance of the multi-channel device. As the number of channels increases, the performance of device and the reliability of SRAM improve because of reduced contact resistance, increased gate dimension and multi-channel compensation effect.
Accountability Tanks Calibration Data Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelberger, James G.; Salazar, William Richard; Finstad, Casey Charles
2017-04-25
MET-1 utilizes tanks to store plutonium in solution. The Nuclear Material Control & Accountability group at LANL requires that MET-1 be able to determine the amount of SNM remaining in solution in the tanks for accountability purposes. For this reason it is desired to determine how well various operators may read the volume of liquid left in the tank with the tank measurement device (glass column or slab). The accuracy of the measurement is then compared to the current SAFE-NMCA acceptance criteria for lean and rich plutonium solutions to determine whether or not the criteria are reasonable and may bemore » met.« less
Wide-range structurally optimized channel for monitoring the certified power of small-core reactors
NASA Astrophysics Data System (ADS)
Koshelev, A. S.; Kovshov, K. N.; Ovchinnikov, M. A.; Pikulina, G. N.; Sokolov, A. B.
2016-12-01
The results of tests of a prototype version of a channel for monitoring the certified power of small-core reactors performed at the BR-K1 reactor at the All-Russian Scientific Research Institute of Experimental Physics are reported. An SNM-11 counter and commercial KNK-4 and KNK-3 compensated ion chambers were used as neutron detectors in the tested channel, and certified NCMM and CCMM measurement modules controlled by a PC with specialized software were used as measuring instruments. The specifics of metrological assurance of calibration of the channel in the framework of reactor power monitoring are discussed.
Wide-range structurally optimized channel for monitoring the certified power of small-core reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koshelev, A. S., E-mail: alexsander.coshelev@yandex.ru; Kovshov, K. N.; Ovchinnikov, M. A.
The results of tests of a prototype version of a channel for monitoring the certified power of small-core reactors performed at the BR-K1 reactor at the All-Russian Scientific Research Institute of Experimental Physics are reported. An SNM-11 counter and commercial KNK-4 and KNK-3 compensated ion chambers were used as neutron detectors in the tested channel, and certified NCMM and CCMM measurement modules controlled by a PC with specialized software were used as measuring instruments. The specifics of metrological assurance of calibration of the channel in the framework of reactor power monitoring are discussed.
Area efficient layout design of CMOS circuit for high-density ICs
NASA Astrophysics Data System (ADS)
Mishra, Vimal Kumar; Chauhan, R. K.
2018-01-01
Efficient layouts have been an active area of research to accommodate the greater number of devices fabricated on a given chip area. In this work a new layout of CMOS circuit is proposed, with an aim to improve its electrical performance and reduce the chip area consumed. The study shows that the design of CMOS circuit and SRAM cells comprising tapered body reduced source fully depleted silicon on insulator (TBRS FD-SOI)-based n- and p-type MOS devices. The proposed TBRS FD-SOI n- and p-MOSFET exhibits lower sub-threshold slope and higher Ion to Ioff ratio when compared with FD-SOI MOSFET and FinFET technology. Other parameters like power dissipation, delay time and signal-to-noise margin of CMOS inverter circuits show improvement when compared with available inverter designs. The above device design is used in 6-T SRAM cell so as to see the effect of proposed layout on high density integrated circuits (ICs). The SNM obtained from the proposed SRAM cell is 565 mV which is much better than any other SRAM cell designed at 50 nm gate length MOS device. The Sentaurus TCAD device simulator is used to design the proposed MOS structure.
SNMIB/Apollo protects leading-strand telomeres against NHEJ-mediated repair.
Lam, Yung C; Akhter, Shamima; Gu, Peili; Ye, Jing; Poulet, Anaïs; Giraud-Panis, Marie-Josèphe; Bailey, Susan M; Gilson, Eric; Legerski, Randy J; Chang, Sandy
2010-07-07
Progressive telomere attrition or deficiency of the protective shelterin complex elicits a DNA damage response as a result of a cell's inability to distinguish dysfunctional telomeric ends from DNA double-strand breaks. SNMIB/Apollo is a shelterin-associated protein and a member of the SMN1/PSO2 nuclease family that localizes to telomeres through its interaction with TRF2. Here, we generated SNMIB/Apollo knockout mouse embryo fibroblasts (MEFs) to probe the function of SNMIB/Apollo at mammalian telomeres. SNMIB/Apollo null MEFs exhibit an increased incidence of G2 chromatid-type fusions involving telomeres created by leading-strand DNA synthesis, reflective of a failure to protect these telomeres after DNA replication. Mutations within SNMIB/Apollo's conserved nuclease domain failed to suppress this phenotype, suggesting that its nuclease activity is required to protect leading-strand telomeres. SNMIB/Apollo(-/-)ATM(-/-) MEFs display robust telomere fusions when Trf2 is depleted, indicating that ATM is dispensable for repair of uncapped telomeres in this setting. Our data implicate the 5'-3' exonuclease function of SNM1B/Apollo in the generation of 3' single-stranded overhangs at newly replicated leading-strand telomeres to protect them from engaging the non-homologous end-joining pathway.
Y-12 Integrated Materials Management System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alspaugh, D. H.; Hickerson, T. W.
2002-06-03
The Integrated Materials Management System, when fully implemented, will provide the Y-12 National Security Complex with advanced inventory information and analysis capabilities and enable effective assessment, forecasting and management of nuclear materials, critical non-nuclear materials, and certified supplies. These capabilities will facilitate future Y-12 stockpile management work, enhance interfaces to existing National Nuclear Security Administration (NNSA) corporate-level information systems, and enable interfaces to planned NNSA systems. In the current national nuclear defense environment where, for example, weapons testing is not permitted, material managers need better, faster, more complete information about material properties and characteristics. They now must manage non-special nuclearmore » material at the same high-level they have managed SNM, and information capabilities about both must be improved. The full automation and integration of business activities related to nuclear and non-nuclear materials that will be put into effect by the Integrated Materials Management System (IMMS) will significantly improve and streamline the process of providing vital information to Y-12 and NNSA managers. This overview looks at the kinds of information improvements targeted by the IMMS project, related issues, the proposed information architecture, and the progress to date in implementing the system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, Charles G; Wallace, Richard K; Ireland, John R
2009-01-01
This paper is an extension to earlier studies that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) and alternate nuclear materials (ANM) associated with the PUREX, UREX, coextraction, THOREX, and PYROX reprocessing schemes. This study extends the figure of merit (FOM) for evaluating attractiveness to cover a broad range of proliferant State and sub-national group capabilities. This study also considers those materials that will be recycled and burned, possibly multiple times, in LWRs [e.g., plutonium in the form of mixed oxide (MOX) fuel]. The primary conclusion of this study is that all fissile material needs to bemore » rigorously safeguarded to detect diversion by a State and provided the highest levels of physical protection to prevent theft by sub-national groups; no 'silver bullet' has been found that will permit the relaxation of current international safeguards or national physical security protection levels. This series of studies has been performed at the request of the United States Department of Energy (DOE) and is based on the calculation of 'attractiveness levels' that are expressed in terms consistent with, but normally reserved for nuclear materials in DOE nuclear facilities. The expanded methodology and updated findings are presented. Additionally, how these attractiveness levels relate to proliferation resistance and physical security are discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, C. G.; Ebbinghaus, B. B.; Sleaford, Brad W.
2009-07-09
This paper is an extension to earlier studies [1,2] that examined the attractiveness of materials mixtures containing special nuclear materials (SNM) and alternate nuclear materials (ANM) associated with the PUREX, UREX, coextraction, THOREX, and PYROX reprocessing schemes. This study extends the figure of merit (FOM) for evaluating attractiveness to cover a broad range of proliferant State and sub-national group capabilities. This study also considers those materials that will be recycled and burned, possibly multiple times, in LWRs [e.g., plutonium in the form of mixed oxide (MOX) fuel]. The primary conclusion of this study is that all fissile material needs tomore » be rigorously safeguarded to detect diversion by a State and provided the highest levels of physical protection to prevent theft by sub-national groups; no “silver bullet” has been found that will permit the relaxation of current international safeguards or national physical security protection levels. This series of studies has been performed at the request of the United States Department of Energy (DOE) and is based on the calculation of "attractiveness levels" that are expressed in terms consistent with, but normally reserved for nuclear materials in DOE nuclear facilities [3]. The expanded methodology and updated findings are presented. Additionally, how these attractiveness levels relate to proliferation resistance and physical security are discussed.« less
Sharma, Hemant K; Arias-Ugarte, Renzo; Metta-Magana, Alejandro; Pannell, Keith H
2010-07-07
Formation of an Sn-CH(3) bond, concomitantly with an Sn-M (M = Fe, Mo), is readily achieved from the photochemical reactions of (t)Bu(2)SnH(2) with (eta(5)-C(5)H(5))M(CO)(n)Me (M = Fe, n = 2; M = Mo, n = 3) via the intermediacy of (eta(5)-C(5)H(5))M(CO)(n)Sn(t)Bu(2)H.
Advanced applications of cosmic-ray muon radiography
NASA Astrophysics Data System (ADS)
Perry, John
The passage of cosmic-ray muons through matter is dominated by the Coulomb interaction with electrons and atomic nuclei. The muon's interaction with electrons leads to continuous energy loss and stopping through the process of ionization. The muon's interaction with nuclei leads to angular diffusion. If a muon stops in matter, other processes unfold, as discussed in more detail below. These interactions provide the basis for advanced applications of cosmic-ray muon radiography discussed here, specifically: 1) imaging a nuclear reactor with near horizontal muons, and 2) identifying materials through the analysis of radiation lengths weighted by density and secondary signals that are induced by cosmic-ray muon trajectories. We have imaged a nuclear reactor, type AGN-201m, at the University of New Mexico, using data measured with a particle tracker built from a set of sealed drift tubes, the Mini Muon Tracker (MMT). Geant4 simulations were compared to the data for verification and validation. In both the data and simulation, we can identify regions of interest in the reactor including the core, moderator, and shield. This study reinforces our claims for using muon tomography to image reactors following an accident. Warhead and special nuclear materials (SNM) imaging is an important thrust for treaty verification and national security purposes. The differentiation of SNM from other materials, such as iron and aluminum, is useful for these applications. Several techniques were developed for material identification using cosmic-ray muons. These techniques include: 1) identifying the radiation length weighted by density of an object and 2) measuring the signals that can indicate the presence of fission and chain reactions. By combining the radiographic images created by tracking muons through a target plane with the additional fission neutron and gamma signature, we are able to locate regions that are fissionable from a single side. The following materials were imaged with this technique: aluminum, concrete, steel, lead, and uranium. Provided that there is sufficient mass, U-235 could be differentiated from U-238 through muon induced fission.
NASA Astrophysics Data System (ADS)
Ginzburg, D.; Knafo, Y.; Manor, A.; Seif, R.; Ghelman, M.; Ellenbogen, M.; Pushkarsky, V.; Ifergan, Y.; Semyonov, N.; Wengrowicz, U.; Mazor, T.; Kadmon, Y.; Cohen, Y.; Osovizky, A.
2015-06-01
There is a need to develop new personal radiation detector (PRD) technologies that can be mass produced. On August 2013, DARPA released a request for information (RFI) seeking innovative radiation detection technologies. In addition, on December 2013, a Broad Agency Announcement (BAA) for the SIGMA program was released. The RFI requirements focused on a sensor that should possess three main properties: low cost, high compactness and radioisotope identification capabilities. The identification performances should facilitate the detection of a hidden threat, ranging from special nuclear materials (SNM) to commonly used radiological sources. Subsequently, the BAA presented the specific requirements at an instrument level and provided a comparison between the current market status (state-of-the-art) and the SIGMA program objectives. This work presents an optional alternative for both the detection technology (sensor with communication output and without user interface) for DARPA's initial RFI and for the PRD required by the SIGMA program. A broad discussion is dedicated to the method proposed to fulfill the program objectives and to the selected alternative that is based on the PDS-GO design and technology. The PDS-GO is the first commercially available PRD that is based on a scintillation crystal optically coupled with a silicon photomultiplier (SiPM), a solid-state light sensor. This work presents the current performance of the instrument and possible future upgrades based on recent technological improvements in the SiPM design. The approach of utilizing the SiPM with a commonly available CsI(Tl) crystal is the key for achieving the program objectives. This approach provides the appropriate performance, low cost, mass production and small dimensions; however, it requires a creative approach to overcome the obstacles of the solid-state detector dark current (noise) and gain stabilization over a wide temperature range. Based on the presented results, we presume that the proposed approach of SiPM, with pixel size of 35 μm, coupled to a scintillation material (for gamma and neutron detection) ensures the availability and low cost of the key components. Furthermore, automated manufacturing process enables mass production, thereby fulfilling the SIGMA program requirements, both as a sensor (assimilated with mobile device) and as a full detection device.
Jena, Ashok Kumar; Rattan, Vidya; Singh, Satinder Pal; Utreja, Ashok Kumar; Sombir, Singh
2016-03-01
To test the hypothesis that there is no immediate and long-term effects of maxillary distraction osteogenesis (DO) on nasal index among adult subjects with cleft lip and palate deformities. Twelve adult subjects in the age range of 17-20 years with complete unilateral cleft lip and palate underwent advancement of maxilla by DO. The immediate and long-term effects of maxillary DO on nasal index were evaluated from extra-oral full face frontal photographs recorded prior to DO (T0), at the end of active DO (T1) and at least 2-years after the DO (T2). The ANOVA, Post Hoc test (Bonferroni) and Pearson correlation coefficients were used. The probability value (P value) 0.05 was considered as statistically significant. SNM angle and Ptm-M distance increased significantly by DO (P < 0.001). The nasal index increased significantly (P < 0.01) by 13.85 % from T0 value of 85.15 ± 4.49 to 99.02 ± 11.16 % at the end of active distraction (T1) and by 12.69 to 97.84 ± 9.14 % at the end of long-term follow-up (T2). The correlation between sagittal maxillary advancement and nasal index was statistically significant (P < 0.001). For each millimeter of maxillary advancement, the nasal index increased by 1.38 % and 1.8 % at the end of active distraction and long-term follow-up respectively. The advancement of maxilla by distraction osteogenesis among subjects with cleft lip and palate deformities increased nasal index significantly.
ACR-SNM Task Force on Nuclear Medicine Training: report of the task force.
Guiberteau, Milton J; Graham, Michael M
2011-06-01
The expansion of knowledge and technological advances in nuclear medicine and radiology require physicians to have more expertise in functional and anatomic imaging. The convergence of these two specialties into the new discipline of molecular imaging has also begun to place demands on residency training programs for additional instruction in physiology and molecular biology. These changes have unmasked weaknesses in current nuclear medicine and radiology training programs. Adding to the impetus for change are the attendant realities of the job market and uncertain employment prospects for physicians trained in nuclear medicine but not also trained in diagnostic radiology. With this background, the ACR and the Society of Nuclear Medicine convened the Task Force on Nuclear Medicine Training to define the issues and develop recommendations for resident training.
Graphene hybrids: synthesis strategies and applications in sensors and sensitized solar cells
Badhulika, Sushmee; Terse-Thakoor, Trupti; Villarreal, Claudia; Mulchandani, Ashok
2015-01-01
Graphene exhibits unique 2-D structural, chemical, and electronic properties that lead to its many potential applications. In order to expand the scope of its usage, graphene hybrids which combine the synergetic properties of graphene along with metals/metal oxides and other nanostructured materials have been synthesized and are a widely emerging field of research. This review presents an overview of the recent progress made in the field of graphene hybrid architectures with a focus on the synthesis of graphene-carbon nanotube (G-CNT), graphene-semiconductor nanomaterial (G-SNM), and graphene-metal nanomaterial (G-MNM) hybrids. It attempts to identify the bottlenecks involved and outlines future directions for development and comprehensively summarizes their applications in the field of sensing and sensitized solar cells. PMID:26176007
DYNSYL: a general-purpose dynamic simulator for chemical processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patterson, G.K.; Rozsa, R.B.
1978-09-05
Lawrence Livermore Laboratory is conducting a safeguards program for the Nuclear Regulatory Commission. The goal of the Material Control Project of this program is to evaluate material control and accounting (MCA) methods in plants that handle special nuclear material (SNM). To this end we designed and implemented the dynamic chemical plant simulation program DYNSYL. This program can be used to generate process data or to provide estimates of process performance; it simulates both steady-state and dynamic behavior. The MCA methods that may have to be evaluated range from sophisticated on-line material trackers such as Kalman filter estimators, to relatively simplemore » material balance procedures. This report describes the overall structure of DYNSYL and includes some example problems. The code is still in the experimental stage and revision is continuing.« less
Novel Cyclotron-Based Radiometal Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeGrado, Timothy R.
2013-10-31
Accomplishments: (1) Construction of prototype solution target for radiometal production; (2) Testing of prototype target for production of following isotopes: a. Zr-89. Investigation of Zr-89 production from Y-89 nitrate solution. i. Defined problems of gas evolution and salt precipitation. ii. Solved problem of precipitation by addition of nitric acid. iii. Solved gas evolution problem with addition of backpressure regulator and constant degassing of target during irradiations. iv. Investigated effects of Y-89 nitrate concentration and beam current. v. Published abstracts at SNM and ISRS meetings; (3) Design of 2nd generation radiometal solution target. a. Included reflux chamber and smaller target volumemore » to conserve precious target materials. b. Included aluminum for prototype and tantalum for working model. c. Included greater varicosities for improved heat transfer; and, (4) Construction of 2nd generation radiometal solution target started.« less
Conducting Layered Organic-inorganic Halides Containing <110>-Oriented Perovskite Sheets.
Mitzi, D B; Wang, S; Feild, C A; Chess, C A; Guloy, A M
1995-03-10
Single crystals of the layered organic-inorganic perovskites, [NH(2)C(I=NH(2)](2)(CH(3)NH(3))m SnmI3m+2, were prepared by an aqueous solution growth technique. In contrast to the recently discovered family, (C(4)H(9)NH(3))(2)(CH(3)NH(3))n-1SnnI3n+1, which consists of (100)-terminated perovskite layers, structure determination reveals an unusual structural class with sets of m <110>-oriented CH(3)NH(3)SnI(3) perovskite sheets separated by iodoformamidinium cations. Whereas the m = 2 compound is semiconducting with a band gap of 0.33 +/- 0.05 electron volt, increasing m leads to more metallic character. The ability to control perovskite sheet orientation through the choice of organic cation demonstrates the flexibility provided by organic-inorganic perovskites and adds an important handle for tailoring and understanding lower dimensional transport in layered perovskites.
McKee, Bruce D.; Yan, Rihui; Tsai, Jui-He
2012-01-01
Meiosis entails sorting and separating both homologous and sister chromatids. The mechanisms for connecting sister chromatids and homologs during meiosis are highly conserved and include specialized forms of the cohesin complex and a tightly regulated homolog synapsis/recombination pathway designed to yield regular crossovers between homologous chromatids. Drosophila male meiosis is of special interest because it dispenses with large segments of the standard meiotic script, particularly recombination, synapsis and the associated structures. Instead, Drosophila relies on a unique protein complex composed of at least two novel proteins, SNM and MNM, to provide stable connections between homologs during meiosis I. Sister chromatid cohesion in Drosophila is mediated by cohesins, ring-shaped complexes that entrap sister chromatids. However, unlike other eukaryotes Drosophila does not rely on the highly conserved Rec8 cohesin in meiosis, but instead utilizes two novel cohesion proteins, ORD and SOLO, which interact with the SMC1/3 cohesin components in providing meiotic cohesion. PMID:23087836
Containment Prospectus for the TRUMPET Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pawloski, G A
2004-02-05
TRUMPET is a series of dynamic subcritical experiments planned for execution in the U1a.102D alcove of the U1a Complex at the Nevada Test Site (NTS). The location of LLNL drifts at the U1a Complex is shown in Figure 1. The data from the TRUMPET experiments will be used in the Stockpile Stewardship Program to assess the aging of nuclear weapons components and to better model the long-term performance of weapons in the enduring stockpile. The TRUMPET series of experiments will be conducted in an almost identical way as the OBOE series of experiments. Individual TRUMPET experiments will be housed inmore » an experiment vessel, as was done for OBOE. These vessels are the same as those utilized for OBOE. All TRUMPET experiments will occur in the zero room in the U1a.102D alcove, which is on the opposite side of the U1a.102 drift from U1a.102C, which housed the OBOE experiments. The centerlines of these two alcoves are separated by only 10 feet. As with OBOE experiments, expended TRUMPET experiment vessels will be moved to the back of the alcove and entombed in grout. After the TRUMPET series of experiments is completed, another experiment will be sited in the U1a.102D alcove and it will be the final experiment in the zero room, as was similarly done for the OBOE series of experiments followed by the execution of the PIANO experiment. Each experimental package for TRUMPET will be composed of high explosive (HE) and special nuclear material (SNM) in a subcritical assembly. Each experimental package will be placed in an experimental vessel within the TRUMPET zero room in the U1a.102D alcove. The containment plan for the TRUMPET experiments utilizes a two-nested containment vessel concept, similar to OBOE and other subcritical experiments in the U1a Complex. The first containment vessel is formed by the primary containment barrier that seals the U1a.102D drift. The second containment vessel is formed by the secondary containment barrier in the U1a.100 drift. While it is likely that the experiment vessel will contain the SNM from the experiment, the containment plan for the TRUMPET experiments only assumes that the experiment vessel provides shock mitigation and serves as a sink for the heat produced by the detonation of the HE. It is possible that one or more of the experiment vessels may seep SNM into the zero room from a failure of a seal on the vessel. This containment plan covers the entire series of TRUMPET experiments. At this time, we don't know exactly how many experiments will actually be conducted in the TRUMPET series. However, we know that the maximum planned number of experiments in the TRUMPET series is 20. This number may be modified on the basis of results obtained from each TRUMPET experiment. After the final experiment in the TRUMPET series is completed, a larger experiment will be conducted in the U1a.102D alcove. A separate containment plan will be developed and presented to the Containment Review Panel (CRP) for that larger experiment. As with OBOE, this containment plan is intended to cover all TRUMPET experiments. We will not develop a separate containment plan for each experiment. Before each experiment we will present a statement to the CRP that each TRUMPET experiment falls within the parameters presented in this document. If an experiment falls outside the parameters in this document, a containment plan for that experiment will be developed and presented to the CRP for a full containment review.« less
Delay-Line Three-Dimensional Position Sensitive Radiation Detection
NASA Astrophysics Data System (ADS)
Jeong, Manhee
High-resistivity silicon(Si) in large volumes and with good charge carrier transport properties has been produced and achieved success as a radiation detector material over the past few years due to its relatively low cost as well as the availability of well-established processing technologies. One application of that technology is in the fabrication of various position-sensing topologies from which the incident radiation's direction can be determined. We have succeeded in developing the modeling tools for investigating different position-sensing schemes and used those tools to examine both amplitude-based and time-based methods, an assessment that indicates that fine position-sensing can be achieved with simpler readout designs than are conventionally deployed. This realization can make ubiquitous and inexpensive deployment of special nuclear materials (SNM) detecting technology becomes more feasible because if one can deploy position-sensitive semiconductor detectors with only one or two contacts per side. For this purpose, we have described the delay-line radiation detector and its optimized fabrication. The semiconductor physics were simulated, the results from which guided the fabrication of the guard ring structure and the detector electrode, both of which included metal-field-plates. The measured improvement in the leakage current was confirmed with the fabricated devices, and the structures successfully suppressed soft-breakdown. We also demonstrated that fabricating an asymmetric strip-line structure successfully minimizing the pulse shaping and increases the distance through which one can propagate the information of the deposited charge distribution. With fabricated delay-line detectors we can acquire alpha spectra (Am-241) and gamma spectra (Ba-133, Co-57 and Cd-109). The delay-line detectors can therefore be used to extract the charge information from both ion and gamma-ray interactions. Furthermore, standard charge-sensitive circuits yield high SNR pulses. The detectors and existing electronics can therefore be used to yield imaging instruments for neutron and gamma-rays, in the case of silicon. For CZT, we would prefer to utilize current sensing to be able to clearly isolate the effects of the various charge-transport non-idealities, the full realization of which awaits the fabrication of the custom-designed TIA chip.
NASA Astrophysics Data System (ADS)
Ishii, Yuichiro; Tanaka, Miki; Yabuuchi, Makoto; Sawada, Yohei; Tanaka, Shinji; Nii, Koji; Lu, Tien Yu; Huang, Chun Hsien; Sian Chen, Shou; Tse Kuo, Yu; Lung, Ching Cheng; Cheng, Osbert
2018-04-01
We propose a highly symmetrical 10 transistor (10T) 2-read/write (2RW) dual-port (DP) static random access memory (SRAM) bitcell in 28 nm high-k/metal-gate (HKMG) planar bulk CMOS. It replaces the conventional 8T 2RW DP SRAM bitcell without any area overhead. It significantly improves the robustness of process variations and an asymmetric issue between the true and bar bitline pairs. Measured data show that read current (I read) and read static noise margin (SNM) are respectively boosted by +20% and +15 mV by introducing the proposed bitcell with enlarged pull-down (PD) and pass-gate (PG) N-channel MOSs (NMOSs). The minimum operating voltage (V min) of the proposed 256 kbit 10T DP SRAM is 0.53 V in the TT process, 25 °C under the worst access condition with read/write disturbances, and improved by 90 mV (15%) compared with the conventional one.
LANL Safeguards and Security Assurance Program. Revision 6
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-03
The Safeguards and Security (S and S) Assurance Program provides a continuous quality improvement approach to ensure effective, compliant S and S program implementation throughout the Los Alamos National Laboratory. Any issues identified through the various internal and external assessments are documented, tracked and closed using the Safeguards and Security Issue Management Program. The Laboratory utilizes an integrated S and S systems approach to protect US Department of Energy (DOE) interests from theft or diversion of special nuclear material (SNM), sabotage, espionage, loss or theft of classified/controlled matter or government property, and other hostile acts that may cause unacceptable impactsmore » on national security, health and safety of employees and the public, and the environment. This document explains the basis, scope, and conduct of the S and S process to include: self-assessments, issue management, risk assessment, and root cause analysis. It also provides a discussion of S and S topical areas, roles and responsibilities, process flow charts, minimum requirements, methodology, terms, and forms.« less
Measurement of the photoneutron flux density distribution from cylindrical targets
NASA Astrophysics Data System (ADS)
Golovkov, V. M.; Basina, T. N.; Yakovlev, M. R.
1989-09-01
Measurements are performed of the density of photoneutron fluxes from cylindrical targets of2H2O (diameter 64 and height 86 mm), Be (outer diameter 70, inner diameter 40, height 100mm), and238U (diameter 44.5 mm, height 50 mm) under the action of braking radiation from electrons with energies of 4 to 8 MeV in order to determine the effect of target form and orientation relative to the detector upon the recorded photoneutron level. The fluxes were measured by an “all-wave” neutron detector based on an SNM-11 counter in a paraffin retarder at an angle of 90‡ to the axis of the braking radiation beam for various target orientations relative to the detector. Measurement results are compared to calculations. Photoneutron fluxes from heavy water and beryllium targets of the indicated dimensions were also measured for angles of 90, 135, and 167‡. An isotropic nature was noted in the photoneutron fluxes from both targets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopotic, James D.; Ferri, Mark S.; Buttram, Claude
The East Tennessee Technology Park (ETTP) is the site of five former gaseous diffusion plant (GDP) process buildings that were used to enrich uranium from 1945 to 1985. The process equipment in the original two buildings (K-25 and K-27) was used for the production of highly enriched uranium (HEU), while that in the three later buildings (K-29, K-31 and K-33) produced low enriched uranium (LEU). Equipment was contaminated primarily with uranium and to a lesser extent technetium (Tc). Decommissioning of the GDP process buildings has presented several unique challenges and produced many lessons-learned. Among these is the importance of good,more » up-front characterization in developing the best demolition approach. Also, chemical cleaning of process gas equipment and piping (PGE) prior to shutdown should be considered to minimize the amount of hold-up material that must be removed by demolition crews. Another lesson learned is to maintain shutdown buildings in a dry state to minimize structural degradation which can significantly complicate characterization, deactivation and demolition efforts. Perhaps the most important lesson learned is that decommissioning GDP process buildings is first and foremost a waste logistics challenge. Innovative solutions are required to effectively manage the sheer volume of waste generated from decontamination and demolition (D and D) of these enormous facilities. Finally, close coordination with Security is mandatory to effectively manage Special Nuclear Material (SNM) and classified equipment issues. (authors)« less
Growth, structural, thermal, dielectric and optical studies on HBST crystal: A potential THz emitter
NASA Astrophysics Data System (ADS)
Ma, Yuzhe; Teng, Bing; Cao, Lifeng; Zhong, Degao; Ji, Shaohua; Teng, Fei; Liu, Jiaojiao; Yao, Yuan; Tang, Jie; Tong, Jiaming
2018-02-01
The efficient organic nonlinear optical material 4-hydroxy benzaldehyde-N-methyl 4-stilbazolium tosylate (HBST) was grown from methanol by slope nucleation method combined with slow cooling (SNM-SC) for the first time. The optimum growth conditions based on the cooling rate was further investigated. The single crystal X-ray diffraction (XRD) revealed that the chromophores of HBST crystal make an angle of about 33° with respect to the a-axis, which is close to the optimum of Terahertz (THz)-wave generation and electro-optics applications. NMR and FT-IR spectral studies have been performed to ascertain various functional groups present in the sample. Futhermore, the thermal stability and decomposition stages were analyzed through TG-DTA and DSC techniques. The dielectric constant and dielectric loss of HBST crystal have been studied. Critical optical properties like the absorption coefficient, refractive index, cut-off wavelength and band gap energy were calculated. Photoluminescence (PL) exication studies indicated green emission occured at 507 nm. All the results of HBST crystal make it a promising candidate in the fields of optoelectronic and the generation of THz.
Real-time multi-mode neutron multiplicity counter
Rowland, Mark S; Alvarez, Raymond A
2013-02-26
Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.
Studies in support of an SNM cutoff agreement: The PUREX exercise
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanbro, W.D.; Libby, R.; Segal, J.
1995-07-01
On September 23, 1993, President Clinton, in a speech before the United Nations General Assembly, called for an international agreement banning the production of plutonium and highly enriched uranium for nuclear explosive purposes. A major element of any verification regime for such an agreement would probably involve inspections of reprocessing plants in Nuclear Nonproliferation Treaty weapons states. Many of these are large facilities built in the 1950s with no thought that they would be subject to international inspection. To learn about some of the problems that might be involved in the inspection of such large, old facilities, the Department ofmore » Energy, Office of Arms Control and Nonproliferation, sponsored a mock inspection exercise at the PUREX plant on the Hanford Site. This exercise examined a series of alternatives for inspections of the PUREX as a model for this type of facility at other locations. A series of conclusions were developed that can be used to guide the development of verification regimes for a cutoff agreement at reprocessing facilities.« less
Performance Test Data Analysis of Scintillation Cameras
NASA Astrophysics Data System (ADS)
Demirkaya, Omer; Mazrou, Refaat Al
2007-10-01
In this paper, we present a set of image analysis tools to calculate the performance parameters of gamma camera systems from test data acquired according to the National Electrical Manufacturers Association NU 1-2001 guidelines. The calculation methods are either completely automated or require minimal user interaction; minimizing potential human errors. The developed methods are robust with respect to varying conditions under which these tests may be performed. The core algorithms have been validated for accuracy. They have been extensively tested on images acquired by the gamma cameras from different vendors. All the algorithms are incorporated into a graphical user interface that provides a convenient way to process the data and report the results. The entire application has been developed in MATLAB programming environment and is compiled to run as a stand-alone program. The developed image analysis tools provide an automated, convenient and accurate means to calculate the performance parameters of gamma cameras and SPECT systems. The developed application is available upon request for personal or non-commercial uses. The results of this study have been partially presented in Society of Nuclear Medicine Annual meeting as an InfoSNM presentation.
Touzot, Fabien; Callebaut, Isabelle; Soulier, Jean; Gaillard, Laetitia; Azerrad, Chantal; Durandy, Anne; Fischer, Alain; de Villartay, Jean-Pierre; Revy, Patrick
2010-01-01
Telomeres, the protein–DNA complexes at the ends of linear chromosomes, are protected and regulated by the shelterin molecules, the telomerase complex, and other accessory factors, among which is Apollo, a DNA repair factor of the β-lactamase/β-CASP family. Impaired telomere protection in humans causes dyskeratosis congenita and Hoyeraal–Hreidarsson (HH) syndrome, characterized by premature aging, bone marrow failure, and immunodeficiency. We identified a unique Apollo splice variant (designated Apollo-Δ) in fibroblasts from a patient with HH syndrome. Apollo-Δ generates a dominant negative form of Apollo lacking the telomeric repeat-binding factor homology (TRFH)-binding motif (TBM) required for interaction with the shelterin TRF2 at telomeres. Apollo-Δ hampers the proper replication of telomeres, leading to major telomeric dysfunction and cellular senescence, but maintains its DNA interstrand cross-link repair function in the whole genome. These results identify Apollo as a crucial actor in telomere maintenance in vivo, independent of its function as a general DNA repair factor. PMID:20479256
Touzot, Fabien; Callebaut, Isabelle; Soulier, Jean; Gaillard, Laetitia; Azerrad, Chantal; Durandy, Anne; Fischer, Alain; de Villartay, Jean-Pierre; Revy, Patrick
2010-06-01
Telomeres, the protein-DNA complexes at the ends of linear chromosomes, are protected and regulated by the shelterin molecules, the telomerase complex, and other accessory factors, among which is Apollo, a DNA repair factor of the beta-lactamase/beta-CASP family. Impaired telomere protection in humans causes dyskeratosis congenita and Hoyeraal-Hreidarsson (HH) syndrome, characterized by premature aging, bone marrow failure, and immunodeficiency. We identified a unique Apollo splice variant (designated Apollo-Delta) in fibroblasts from a patient with HH syndrome. Apollo-Delta generates a dominant negative form of Apollo lacking the telomeric repeat-binding factor homology (TRFH)-binding motif (TBM) required for interaction with the shelterin TRF2 at telomeres. Apollo-Delta hampers the proper replication of telomeres, leading to major telomeric dysfunction and cellular senescence, but maintains its DNA interstrand cross-link repair function in the whole genome. These results identify Apollo as a crucial actor in telomere maintenance in vivo, independent of its function as a general DNA repair factor.
2014-01-01
Background The distribution of the roles and responsibilities of long-term condition management (LTCM) outside of formal health services implicates a wide set of relationships and activities of involvement. Yet, compared to studies of professional implementation, patient systems of implementation remain under-investigated. The aim of this paper is to explore the work, meaning and function attributed to ‘weaker’ ties relative to other more bonding relationships in order to identify the place of these within a context of systems of support for long-term conditions. Methods This is a mixed methods survey with nested qualitative study. A total of 300 people from deprived areas in the North West of England with chronic illnesses took part in a survey conducted in 2010 to 2011. A concentric circles diagram was used as a research tool with which participants identified 2,544 network members who contributed to illness management. Notions of ‘work’ were used to describe activities associated with chronic illness and to identify how weaker ties are included and perceived to be involved through social network members (SNM) contributions. Results The results provide an articulation of how SNMs are substantially involved in weak tie illness management. Weaker ties constituted 16.1% of network membership involved in illness work. The amount of work undertaken was similar but less than that of stronger ties. Weaker ties appeared more durable and less liable to loss over time than stronger ties. The qualitative accounts suggested that weak ties enabled the moral positioning of the self-managing ‘self’ and acted on the basis of a strong sense of reciprocity. Conclusions Weak ties act as an acceptable bridge between a sense of personal agency and control and the need for external support because it is possible to construct a sense of moral acceptability through reciprocal exchange. Access to weak tie resources needs to be taken into account when considering the ways in which systems of health implementation for chronic illness are designed and delivered. PMID:24524253
Ma, Yuzhe; Teng, Bing; Cao, Lifeng; Zhong, Degao; Ji, Shaohua; Teng, Fei; Liu, Jiaojiao; Yao, Yuan; Tang, Jie; Tong, Jiaming
2018-02-05
The efficient organic nonlinear optical material 4-hydroxy benzaldehyde-N-methyl 4-stilbazolium tosylate (HBST) was grown from methanol by slope nucleation method combined with slow cooling (SNM-SC) for the first time. The optimum growth conditions based on the cooling rate was further investigated. The single crystal X-ray diffraction (XRD) revealed that the chromophores of HBST crystal make an angle of about 33° with respect to the a-axis, which is close to the optimum of Terahertz (THz)-wave generation and electro-optics applications. NMR and FT-IR spectral studies have been performed to ascertain various functional groups present in the sample. Futhermore, the thermal stability and decomposition stages were analyzed through TG-DTA and DSC techniques. The dielectric constant and dielectric loss of HBST crystal have been studied. Critical optical properties like the absorption coefficient, refractive index, cut-off wavelength and band gap energy were calculated. Photoluminescence (PL) exication studies indicated green emission occured at 507nm. All the results of HBST crystal make it a promising candidate in the fields of optoelectronic and the generation of THz. Copyright © 2017 Elsevier B.V. All rights reserved.
Role of RNase MRP in viral RNA degradation and RNA recombination.
Jaag, Hannah M; Lu, Qiasheng; Schmitt, Mark E; Nagy, Peter D
2011-01-01
RNA degradation, together with RNA synthesis, controls the steady-state level of viral RNAs in infected cells. The endoribonucleolytic cleavage of viral RNA is important not only for viral RNA degradation but for RNA recombination as well, due to the participation of some RNA degradation products in the RNA recombination process. To identify host endoribonucleases involved in degradation of Tomato bushy stunt virus (TBSV) in a Saccharomyces cerevisiae model host, we tested eight known endoribonucleases. Here we report that downregulation of SNM1, encoding a component of the RNase MRP, and a temperature-sensitive mutation in the NME1 gene, coding for the RNA component of RNase MRP, lead to reduced production of the endoribonucleolytically cleaved TBSV RNA in yeast. We also show that the highly purified yeast RNase MRP cleaves the TBSV RNA in vitro, resulting in TBSV RNA degradation products similar in size to those observed in yeast cells. Knocking down the NME1 homolog in Nicotiana benthamiana also led to decreased production of the cleaved TBSV RNA, suggesting that in plants, RNase MRP is involved in TBSV RNA degradation. Altogether, this work suggests a role for the host endoribonuclease RNase MRP in viral RNA degradation and recombination.
NASA Astrophysics Data System (ADS)
Rahmat, M.; Modarres, M.
2018-03-01
The averaged effective two-body interaction (AEI), which can be generated through the lowest order constrained variational (LOCV) method for symmetric nuclear matter (SNM) with the input [Reid68, Ann. Phys. 50, 411 (1968), 10.1016/0003-4916(68)90126-7] nucleon-nucleon potential, is used as the effective nucleon-nucleon potential in the folding model to describe the heavy-ion (HI) elastic scattering cross sections. The elastic scattering cross sections of 12C-12C and 16O-16O systems are calculated in the above framework. The results are compared with the corresponding calculations coming from the fitting procedures with the input finite range D D M 3 Y 1 -Reid potential and the available experimental data at different incident energies. It is shown that a reasonable description of the elastic 12C-12C and 16O-16O scattering data at the low and medium energies can be obtained by using the above LOCV AEI, without any need to define a parametrized density-dependent function in the effective nucleon-nucleon potential, which is formally considered in the typical D D M 3 Y 1 -Reid interactions.
Removal of endotoxin from deionized water using micromachined silicon nanopore membranes
NASA Astrophysics Data System (ADS)
Smith, Ross A.; Goldman, Ken; Fissell, William H.; Fleischman, Aaron J.; Zorman, Christian A.; Roy, Shuvo
2011-05-01
Endotoxins are lipopolysaccharide components of the cell membrane of Gram-negative bacteria that trigger the body's innate immune system and can cause shock and death. Water for medical therapy, including parenteral and dialysate solutions, must be free of endotoxin. This purity is challenging to achieve as many Gram-negative bacteria are endemic in the environment, and can thrive in harsh, nutrient-poor conditions. Current methods for removing endotoxin include distillation and reverse osmosis, both of which are resource intensive processes. Membranes that present an absolute barrier to macromolecular passage may be capable of delivering pure water for biomedical applications. In this work, endotoxin has been filtered from aqueous solutions using silicon nanopore membranes (SNMs) with monodisperse pore size distributions. SNMs with critical pore sizes between 26 and 49 nm were challenged with solutions of deionized water spiked with endotoxin and with Pseudomonas cepacia. The filtrate produced by the SNM from Pseudomonas-contaminated water had <1.0 endotoxin unit (EU) ml-1, which meets standards for dialysate purity. This approach suggests a technique for single-step cleanup of heavily contaminated water that may be suitable for field or clinical use.
Analysis of the restricting factors of laser countermeasure active detection technology
NASA Astrophysics Data System (ADS)
Zhang, Yufa; Sun, Xiaoquan
2016-07-01
The detection effect of laser active detection system is affected by various kinds of factors. In view of the application requirement of laser active detection, the influence factors for laser active detection are analyzed. The mathematical model of cat eye target detection distance has been built, influence of the parameters of laser detection system and the environment on detection range and the detection efficiency are analyzed. Various parameters constraint detection performance is simulated. The results show that the discovery distance of laser active detection is affected by the laser divergence angle, the incident angle and the visibility of the atmosphere. For a given detection range, the laser divergence angle and the detection efficiency are mutually restricted. Therefore, in view of specific application environment, it is necessary to select appropriate laser detection parameters to achieve optimal detection effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanzella, E.; Cusano, F.; Fontana, A.
2014-03-01
We report the LBT/MODS1 spectroscopic confirmation of two images of faint Lyα emitters at z = 6.4 behind the Frontier Fields galaxy cluster MACSJ0717.5+3745. A wide range of lens models suggests that the two images are highly magnified, with a strong lower limit of μ > 5. These are the faintest z > 6 candidates spectroscopically confirmed to date. These may also be multiple images of the same z = 6.4 source as supported by their similar intrinsic properties, but the lens models are inconclusive regarding this interpretation. To be cautious, we derive the physical properties of each image individually.more » Thanks to the high magnification, the observed near-infrared (restframe ultraviolet) part of the spectral energy distributions and Lyα lines are well detected with S/N(m {sub 1500}) ≳ 10 and S/N(Lyα) ≅ 10-15. Adopting μ > 5, the absolute magnitudes, M {sub 1500}, and Lyα fluxes are fainter than –18.7 and 2.8 × 10{sup –18} erg s{sup –1} cm{sup –2}, respectively. We find a very steep ultraviolet spectral slope β = –3.0 ± 0.5 (F {sub λ} = λ{sup β}), implying that these are very young, dust-free, and low metallicity objects, made of standard stellar populations or even extremely metal poor stars (age ≲ 30 Myr, E(B – V) = 0 and metallicity 0.0-0.2 Z/Z {sub ☉}). The objects are compact (<1 kpc{sup 2}) and with a stellar mass M {sub *} < 10{sup 8} M {sub ☉}. The very steep β, the presence of the Lyα line, and the intrinsic FWHM (<300 km s{sup –1}) of these newborn objects do not exclude a possible leakage of ionizing radiation. We discuss the possibility that such faint galaxies may resemble those responsible for cosmic reionization.« less
Supervised normalization of microarrays
Mecham, Brigham H.; Nelson, Peter S.; Storey, John D.
2010-01-01
Motivation: A major challenge in utilizing microarray technologies to measure nucleic acid abundances is ‘normalization’, the goal of which is to separate biologically meaningful signal from other confounding sources of signal, often due to unavoidable technical factors. It is intuitively clear that true biological signal and confounding factors need to be simultaneously considered when performing normalization. However, the most popular normalization approaches do not utilize what is known about the study, both in terms of the biological variables of interest and the known technical factors in the study, such as batch or array processing date. Results: We show here that failing to include all study-specific biological and technical variables when performing normalization leads to biased downstream analyses. We propose a general normalization framework that fits a study-specific model employing every known variable that is relevant to the expression study. The proposed method is generally applicable to the full range of existing probe designs, as well as to both single-channel and dual-channel arrays. We show through real and simulated examples that the method has favorable operating characteristics in comparison to some of the most highly used normalization methods. Availability: An R package called snm implementing the methodology will be made available from Bioconductor (http://bioconductor.org). Contact: jstorey@princeton.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20363728
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Song; Huang, Hao, E-mail: huanghao@dlut.edu.cn; Wu, Aimin
2016-10-15
A direct current arc-discharge method was applied to prepare the Sn–M (M=Fe, Al, Ni) bi-alloy nanoparticles. Thermodynamic is introduced to analyze the energy circumstances for the formation of the nanoparticles during the physical condensation process. The electrochemical properties of as-prepared Sn–M alloy nanoparticles are systematically investigated as anodes of Li-ion batteries. Among them, Sn–Fe nanoparticles electrode exhibits high Coulomb efficiency (about 71.2%) in the initial charge/discharge (257.9 mA h g{sup −1}/366.6 mA h g{sup −1}) and optimal cycle stability (a specific reversible capacity of 240 mA h g{sup −1} maintained after 20 cycles) compared with others. Large differences in themore » electrochemical behaviors indicate that the chemical composition and microstructure of the nanoparticles determine the lithium-ion storage properties and the long-term cyclic stability during the charge/discharge process. - Graphical abstract: The growth mechanism and electrochemical performance of Sn-based alloy nanoparticles. - Highlights: • Thermodynamic analyses of oxides on Sn-M nanoparticles surface. • The relationship between chemical components and electrochemical responses. • Sn-Fe nanoparticles show excellent electrode performance.« less
Nucleon effective E-mass in neutron-rich matter from the Migdal–Luttinger jump
Cai, Bao-Jun; Li, Bao-An
2016-03-25
The well-known Migdal-Luttinger theorem states that the jump of the single-nucleon momentum distribution at the Fermi surface is equal to the inverse of the nucleon effective E-mass. Recent experiments studying short-range correlations (SRC) in nuclei using electron-nucleus scatterings at the Jefferson National Laboratory (JLAB) together with model calculations constrained significantly the Migdal-Luttinger jump at saturation density of nuclear matter. We show that the corresponding nucleon effective E-mass is consequently constrained to M-0(*,E)/M approximate to 2.22 +/- 0.35 in symmetric nuclear matter (SNM) and the E-mass of neutrons is smaller than that of protons in neutron-rich matter. Moreover, the average depletionmore » of the nucleon Fermi sea increases (decreases) approximately linearly with the isospin asymmetry delta according to kappa(p/n) approximate to 0.21 +/- 0.06 +/- (0.19 +/- 0.08)delta for protons (neutrons). These results will help improve our knowledge about the space-time non-locality of the single-nucleon potential in neutron-rich nucleonic matter Useful in both nuclear physics and astrophysics. (C) 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). Funded by SCOAP(3).« less
An equivalent n-source for WGPu derived from a spectrum-shifted PuBe source
NASA Astrophysics Data System (ADS)
Ghita, Gabriel; Sjoden, Glenn; Baciak, James; Walker, Scotty; Cornelison, Spring
2008-04-01
We have designed, built, and laboratory-tested a unique shield design that transforms the complex neutron spectrum from PuBe source neutrons, generated at high energies, to nearly exactly the neutron signature leaking from a significant spherical mass of weapons grade plutonium (WGPu). This equivalent "X-material shield assembly" (Patent Pending) enables the harder PuBe source spectrum (average energy of 4.61 MeV) from a small encapsulated standard 1-Ci PuBe source to be transformed, through interactions in the shield, so that leakage neutrons are shifted in energy and yield to become a close reproduction of the neutron spectrum leaking from a large subcritical mass of WGPu metal (mean energy 2.11 MeV). The utility of this shielded PuBe surrogate for WGPu is clear, since it directly enables detector field testing without the expense and risk of handling large amounts of Special Nuclear Materials (SNM) as WGPu. Also, conventional sources using Cf-252, which is difficult to produce, and decays with a 2.7 year half life, could be replaced by this shielded PuBe technology in order to simplify operational use, since a sealed PuBe source relies on Pu-239 (T½=24,110 y), and remains viable for more than hundreds of years.
Final Technical Report: Imaging a Dry Storage Cask with Cosmic Ray Muons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Haori; Hayward, Jason; Chichester, David
The goal of this project is to build a scaled prototype system for monitoring used nuclear fuel (UNF) dry storage casks (DSCs) through cosmic ray muon imaging. Such a system will have the capability of verifying the content inside a DSC without opening it. Because of the growth of the nuclear power industry in the U.S. and the policy decision to ban reprocessing of commercial UNF, the used fuel inventory at commercial reactor sites has been increasing. Currently, UNF needs to be moved to independent spent fuel storage installations (ISFSIs), as its inventory approaches the limit on capacity of on-sitemore » wet storage. Thereafter, the fuel will be placed in shipping containers to be transferred to a final disposal site. The ISFSIs were initially licensed as temporary facilities for ~20-yr periods. Given the cancellation of the Yucca mountain project and no clear path forward, extended dry-cask storage (~100 yr.) at ISFSIs is very likely. From the point of view of nuclear material protection, accountability and control technologies (MPACT) campaign, it is important to ensure that special nuclear material (SNM) in UNF is not stolen or diverted from civilian facilities for other use during the extended storage.« less
Qi, Peng; Zhang, Dun; Wan, Yi
2014-11-01
Sulfate-reducing bacteria (SRB) have been extensively studied in corrosion and environmental science. However, fast enumeration of SRB population is still a difficult task. This work presents a novel specific SRB detection method based on inhibition of cysteine protease activity. The hydrolytic activity of cysteine protease was inhibited by taking advantage of sulfide, the characteristic metabolic product of SRB, to attack active cysteine thiol group in cysteine protease catalytic sites. The active thiol S-sulfhydration process could be used for SRB detection, since the amount of sulfide accumulated in culture medium was highly related with initial bacterial concentration. The working conditions of cysteine protease have been optimized to obtain better detection capability, and the SRB detection performances have been evaluated in this work. The proposed SRB detection method based on inhibition of cysteine protease activity avoided the use of biological recognition elements. In addition, compared with the widely used most probable number (MPN) method which would take up to at least 15days to accomplish whole detection process, the method based on inhibition of papain activity could detect SRB in 2 days, with a detection limit of 5.21×10(2) cfu mL(-1). The detection time for SRB population quantitative analysis was greatly shortened. Copyright © 2014 Elsevier B.V. All rights reserved.
Marinkovic, Serge P; Ford, Joseph C
2018-04-10
To assess whether the utilisation of a motor response of <3 V during Stage 1 sacral neuromodulation (SNM) results in better clinical outcomes compared to >4 V in patients with overactive bladder (OAB) or urinary retention symptoms. An observational, retrospective, double cohort review was conducted of 339 female patients who had experienced medically recalcitrant OAB or urinary retention symptoms. Between September 2001 and September 2014, both cohorts underwent successful Stage 1 to Stage 2 SNM placement. Group A, included 174 women with a motor response at ≤3 V; and Group B, evaluated 110 women with a motor response at ≥4 V for medically recalcitrant OAB. Group C, compared 33 women with a motor response at ≤3 V; and Group D, documented 22 women with a motor response at ≥4 V for non-obstructive urinary retention. Patients completed 3-day voiding diaries, the Urogenital Distress Inventory-6 (UDI-6), Incontinence Impact Questionnaire-7 (IIQ-7), and Patient Global Impression of Improvement Questionnaire. The mean (sd) follow-up was 116.3 (30.3) months in Group A and 112 (34.6) months in Group B (P < 0.354); 150.5 (20.4) months in Group C and 145.8 (17.2) months in Group D (P < 0.38). Successful conversion of Stage 1 to Stage 2 showed statistically significant improvement for both <3-V groups (Groups A and C). Group A had a 93.5% (174/186) conversion rate vs 72.3% (110/152) in Group B for OAB symptoms (P < 0.001). Group C had a 94% (34/36) conversion rate vs 70% (21/30) in Group D (P < 0.017). Defined as a ≥50% reduction in frequency, urgency, urgency incontinence and nocturia, and UDI-6 and IIQ-7 scores, the success rate for Group A was 82.1% (143/174) and for Group B was 63% (69/110) (P < 0.001). The mean battery life improved in both <3-V cohorts (P < 0.001). Annual reprogramming sessions were reduced in Group A and Group C (P < 0.001). Subset analysis of variance showed no statistical improvement in most patient outcomes when 1-V subjects were compared to 2- and 3-V cohorts. However, 32% of 1-V patients (P < 0.001) noted the onset of severe pelvic/perirectal pain and big toe plantar flexion movement with small increments in voltage (0.1-0.2 V) during reprogramming. Only 7% of 2-V and 1% of 3-V patients experienced this complication. Significant improvement was noted (up to 40%) in most clinical voiding parameters in the <3-V patients for both OAB and urinary retention. While <3 V will still statistically improve patient outcomes, a voltage <2 V may elicit self-reprogramming pain with severe bellows and plantar flexion movement, which may discourage patients from therapy adjustments. We recommend randomised, controlled trials to confirm these results. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.
Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slaughter, David M.; Stuart, Cory R.; Klaass, R. Fred
2015-07-01
This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutronsmore » that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)« less
Detecting Human Activity Using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors
2011-09-01
Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors by Sarah H. Walker and Geoffrey H. Goldman...Adelphi, MD 20783-1197 ARL-TR-5729 September 2011 Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors...DD-MM-YYYY) September 2011 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Detecting Human Activity using Acoustic
Detection rates of the MODIS active fire product in the United States
Hawbaker, T.J.; Radeloff, V.C.; Syphard, A.D.; Zhu, Z.; Stewart, S.I.
2008-01-01
MODIS active fire data offer new information about global fire patterns. However, uncertainties in detection rates can render satellite-derived fire statistics difficult to interpret. We evaluated the MODIS 1??km daily active fire product to quantify detection rates for both Terra and Aqua MODIS sensors, examined how cloud cover and fire size affected detection rates, and estimated how detection rates varied across the United States. MODIS active fire detections were compared to 361 reference fires (??? 18??ha) that had been delineated using pre- and post-fire Landsat imagery. Reference fires were considered detected if at least one MODIS active fire pixel occurred within 1??km of the edge of the fire. When active fire data from both Aqua and Terra were combined, 82% of all reference fires were found, but detection rates were less for Aqua and Terra individually (73% and 66% respectively). Fires not detected generally had more cloudy days, but not when the Aqua data were considered exclusively. MODIS detection rates decreased with fire size, and the size at which 50% of all fires were detected was 105??ha when combining Aqua and Terra (195??ha for Aqua and 334??ha for Terra alone). Across the United States, detection rates were greatest in the West, lower in the Great Plains, and lowest in the East. The MODIS active fire product captures large fires in the U.S. well, but may under-represent fires in areas with frequent cloud cover or rapidly burning, small, and low-intensity fires. We recommend that users of the MODIS active fire data perform individual validations to ensure that all relevant fires are included. ?? 2008 Elsevier Inc. All rights reserved.
Al-Nawashi, Malek; Al-Hazaimeh, Obaida M; Saraee, Mohamad
2017-01-01
Abnormal activity detection plays a crucial role in surveillance applications, and a surveillance system that can perform robustly in an academic environment has become an urgent need. In this paper, we propose a novel framework for an automatic real-time video-based surveillance system which can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment. To develop our system, we have divided the work into three phases: preprocessing phase, abnormal human activity detection phase, and content-based image retrieval phase. For motion object detection, we used the temporal-differencing algorithm and then located the motions region using the Gaussian function. Furthermore, the shape model based on OMEGA equation was used as a filter for the detected objects (i.e., human and non-human). For object activities analysis, we evaluated and analyzed the human activities of the detected objects. We classified the human activities into two groups: normal activities and abnormal activities based on the support vector machine. The machine then provides an automatic warning in case of abnormal human activities. It also embeds a method to retrieve the detected object from the database for object recognition and identification using content-based image retrieval. Finally, a software-based simulation using MATLAB was performed and the results of the conducted experiments showed an excellent surveillance system that can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment with no human intervention.
The simulation study on optical target laser active detection performance
NASA Astrophysics Data System (ADS)
Li, Ying-chun; Hou, Zhao-fei; Fan, Youchen
2014-12-01
According to the working principle of laser active detection system, the paper establishes the optical target laser active detection simulation system, carry out the simulation study on the detection process and detection performance of the system. For instance, the performance model such as the laser emitting, the laser propagation in the atmosphere, the reflection of optical target, the receiver detection system, the signal processing and recognition. We focus on the analysis and modeling the relationship between the laser emitting angle and defocus amount and "cat eye" effect echo laser in the reflection of optical target. Further, in the paper some performance index such as operating range, SNR and the probability of the system have been simulated. The parameters including laser emitting parameters, the reflection of the optical target and the laser propagation in the atmosphere which make a great influence on the performance of the optical target laser active detection system. Finally, using the object-oriented software design methods, the laser active detection system with the opening type, complete function and operating platform, realizes the process simulation that the detection system detect and recognize the optical target, complete the performance simulation of each subsystem, and generate the data report and the graph. It can make the laser active detection system performance models more intuitive because of the visible simulation process. The simulation data obtained from the system provide a reference to adjust the structure of the system parameters. And it provides theoretical and technical support for the top level design of the optical target laser active detection system and performance index optimization.
Leusch, Frederic D L; Neale, Peta A; Hebert, Armelle; Scheurer, Marco; Schriks, Merijn C M
2017-02-01
The presence of endocrine disrupting chemicals in the aquatic environment poses a risk for ecosystem health. Consequently there is a need for sensitive tools, such as in vitro bioassays, to monitor endocrine activity in environmental waters. The aim of the current study was to assess whether current in vitro bioassays are suitable to detect endocrine activity in a range of water types. The reviewed assays included androgenic (n=11), progestagenic (n=6), glucocorticoid (n=5), thyroid (n=5) and estrogenic (n=8) activity in both agonist and antagonist mode. Existing in vitro bioassay data were re-evaluated to determine assay sensitivity, with the calculated method detection limit compared with measured hormonal activity in treated wastewater, surface water and drinking water to quantify whether the studied assays were sufficiently sensitive for environmental samples. With typical sample enrichment, current in vitro bioassays are sufficiently sensitive to detect androgenic activity in treated wastewater and surface water, with anti-androgenic activity able to be detected in most environmental waters. Similarly, with sufficient enrichment, the studied mammalian assays are able to detect estrogenic activity even in drinking water samples. Fewer studies have focused on progestagenic and glucocorticoid activity, but some of the reviewed bioassays are suitable for detecting activity in treated wastewater and surface water. Even less is known about (anti)thyroid activity, but the available data suggests that the more sensitive reviewed bioassays are still unlikely to detect this type of activity in environmental waters. The findings of this review can help provide guidance on in vitro bioassay selection and required sample enrichment for optimised detection of endocrine activity in environmental waters. Copyright © 2016 Elsevier Ltd. All rights reserved.
SLIGHTLY IRRADIATED FUEL (SIF) INTERIM DISPOSITION PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
NORTON SH
2010-02-23
CH2M HILL Plateau Remediation Company (CH2M HILL PRC) is proud to submit the Slightly Irradiated Fuel (SIF) Interim Disposition Project for consideration by the Project Management Institute as Project of the Year for 2010. The SIF Project was a set of six interrelated sub-projects that delivered unique stand-alone outcomes, which, when integrated, provided a comprehensive and compliant system for storing high risk special nuclear materials. The scope of the six sub-projects included the design, construction, testing, and turnover of the facilities and equipment, which would provide safe, secure, and compliant Special Nuclear Material (SNM) storage capabilities for the SIF material.more » The project encompassed a broad range of activities, including the following: Five buildings/structures removed, relocated, or built; Two buildings renovated; Structural barriers, fencing, and heavy gates installed; New roadways and parking lots built; Multiple detection and assessment systems installed; New and expanded communication systems developed; Multimedia recording devices added; and A new control room to monitor all materials and systems built. Project challenges were numerous and included the following: An aggressive 17-month schedule to support the high-profile Plutonium Finishing Plant (PFP) decommissioning; Company/contractor changeovers that affected each and every project team member; Project requirements that continually evolved during design and construction due to the performance- and outcome-based nature ofthe security objectives; and Restrictions imposed on all communications due to the sensitive nature of the projects In spite of the significant challenges, the project was delivered on schedule and $2 million under budget, which became a special source of pride that bonded the team. For years, the SIF had been stored at the central Hanford PFP. Because of the weapons-grade piutonium produced and stored there, the PFP had some of the tightest security on the Hanford nuclear reservation. Workers had to pass through metal detectors when they arrived at the plant and materials leaving the plant had to be scanned for security reasons. Whereas other high-security nuclear materials were shipped from the PFP to Savannah River, S.C. as part ofa Department of Energy (DOE) program to consolidate weapons-grade plutonium, it was determined that the SIF should remain onsite pending disposition to a national repository. Nevertheless, the SIF still requires a high level of security that the PFP complex has always provided. With the 60-year PFP mission of producing and storing plutonium concluded, the environmental cleanup plans for Hanford call for the demolition of the 63-building PFP complex. Consequently, if the SIF remained at PFP it not only would have interfered with the environmental cleanup plans, but would have required $100 million in facility upgrades to meet increased national security requirements imposed after the 9/11 terrorist attacks. A new smaller and more cost-effective area was needed to store this material, which led to the SIF Project. Once the SIF project was successfully completed and the SIF was safely removed from PFP, the existing Protected Area at PFP could be removed, and demolition could proceed more quickly without being encumbered by restrictive security requirements that an active Protected Area requires. The lightened PFP security level brought by safely removing and storing the SIF would also yield lowered costs for deactivation and demolition, as well as reduce overall life-cycle costs.« less
Rapid Detection of Urinary Tract Infections via Bacterial Nuclease Activity.
Flenker, Katie S; Burghardt, Elliot L; Dutta, Nirmal; Burns, William J; Grover, Julia M; Kenkel, Elizabeth J; Weaver, Tyler M; Mills, James; Kim, Hyeon; Huang, Lingyan; Owczarzy, Richard; Musselman, Catherine A; Behlke, Mark A; Ford, Bradley; McNamara, James O
2017-06-07
Rapid and accurate bacterial detection methods are needed for clinical diagnostic, water, and food testing applications. The wide diversity of bacterial nucleases provides a rich source of enzymes that could be exploited as signal amplifying biomarkers to enable rapid, selective detection of bacterial species. With the exception of the use of micrococcal nuclease activity to detect Staphylococcus aureus, rapid methods that detect bacterial pathogens via their nuclease activities have not been developed. Here, we identify endonuclease I as a robust biomarker for E. coli and develop a rapid ultrasensitive assay that detects its activity. Comparison of nuclease activities of wild-type and nuclease-knockout E. coli clones revealed that endonuclease I is the predominant DNase in E. coli lysates. Endonuclease I is detectable by immunoblot and activity assays in uropathogenic E. coli strains. A rapid assay that detects endonuclease I activity in patient urine with an oligonucleotide probe exhibited substantially higher sensitivity for urinary tract infections than that reported for rapid urinalysis methods. The 3 hr turnaround time is much shorter than that of culture-based methods, thereby providing a means for expedited administration of appropriate antimicrobial therapy. We suggest this approach could address various unmet needs for rapid detection of E. coli. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.
Distinct frontal and amygdala correlates of change detection for facial identity and expression
Achaibou, Amal; Loth, Eva
2016-01-01
Recruitment of ‘top-down’ frontal attentional mechanisms is held to support detection of changes in task-relevant stimuli. Fluctuations in intrinsic frontal activity have been shown to impact task performance more generally. Meanwhile, the amygdala has been implicated in ‘bottom-up’ attentional capture by threat. Here, 22 adult human participants took part in a functional magnetic resonance change detection study aimed at investigating the correlates of successful (vs failed) detection of changes in facial identity vs expression. For identity changes, we expected prefrontal recruitment to differentiate ‘hit’ from ‘miss’ trials, in line with previous reports. Meanwhile, we postulated that a different mechanism would support detection of emotionally salient changes. Specifically, elevated amygdala activation was predicted to be associated with successful detection of threat-related changes in expression, over-riding the influence of fluctuations in top-down attention. Our findings revealed that fusiform activity tracked change detection across conditions. Ventrolateral prefrontal cortical activity was uniquely linked to detection of changes in identity not expression, and amygdala activity to detection of changes from neutral to fearful expressions. These results are consistent with distinct mechanisms supporting detection of changes in face identity vs expression, the former potentially reflecting top-down attention, the latter bottom-up attentional capture by stimulus emotional salience. PMID:26245835
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaschen, Brian Keith; Bloch, Jeffrey Joseph; Porter, Reid
Morphological signatures of bulk SNM materials have significant promise, but these potential signatures are not fully utilized. This document describes software tools, collectively called the MAMA (Morphological Analysis for Material Attribution) software that can help provide robust and accurate quantification of morphological features in bulk material microscopy images (Optical, SEM). Although many of the specific tools are not unique to Mama, the software package has been designed specifically for nuclear material morphological analysis, and is at a point where it can be easily adapted (by Los Alamos or by collaborators) in response to new, different, or changing forensics needs. Themore » current release of the MAMA software only includes the image quantification, descriptions, and annotation functionality. Only limited information on a sample, its pedigree, and its chemistry are recorded inside this part of the software. This was decision based on initial feedback and the fact that there are several analytical chemistry databases being developed within the community. Currently MAMA is a standalone program that can export quantification results in a basic text format that can be imported into other programs such as Excel and Access. There is also a basic report generating feature that produces HTML formatted pages of the same information. We will be working with collaborators to provide better integration of MAMA into their particular systems, databases and workflows.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bathke, Charles Gary; Wallace, Richard K; Hase, Kevin R
2010-01-01
This paper reports the continued evaluation of the attractiveness of materials mixtures containing special nuclear materials (SNM) associated with various proposed nuclear fuel cycles. Specifically, this paper examines two closed fuel cycles. The first fuel cycle examined is a thorium fuel cycle in which a pressurized heavy water reactor (PHWR) is fueled with mixtures of plutonium/thorium and {sup 233}U/thorium. The used fuel is then reprocessed using the THOREX process and the actinides are recycled. The second fuel cycle examined consists of conventional light water reactors (LWR) whose fuel is reprocessed for actinides that are then fed to and recycled untilmore » consumed in fast-spectrum reactors: fast reactors and accelerator driven systems (ADS). As reprocessing of LWR fuel has already been examined, this paper will focus on the reprocessing of the scheme's fast-spectrum reactors' fuel. This study will indicate what is required to render these materials as having low utility for use in nuclear weapons. Nevertheless, the results of this paper suggest that all reprocessing products evaluated so far need to be rigorously safeguarded and provided high levels of physical protection. These studies were performed at the request of the United States Department of Energy (DOE). The methodology and key findings will be presented.« less
Code of Federal Regulations, 2013 CFR
2013-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2011 CFR
2011-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Code of Federal Regulations, 2013 CFR
2013-01-01
.... III. Detecting Red Flags The Program's policies and procedures should address the detection of Red... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of...
Detection of activated basophils using flow cytometry for diagnosis in atopic patients.
Cozon, G; Ferrándiz, J; Peyramond, D; Brunet, J
1999-01-01
human basophils release mediators of allergy after cross-linking of IgE receptors by allergens. Specific activation of basophils is detectable through flow cytometry (FCM) using an anti-CD63 fluorescein-conjugated monoclonal antibody. this study evaluate the detection of activated basophils by FCM in routine diagnosis of atopic diseases as regard to skin prick tests and specific immunoglobulin E antibodies. whole blood from twenty patients suspected of atopy was preincubated with interleukin-3 (IL-3), then incubated with specific allergens. After staining using anti-CD63 antibodies, activated basophils were detected through FCM. IL-3-preincubation increases the spontaneous expression of CD63 even at low concentrations (0.1 ng/ml) on the basophils of 2 patients out of 20. The sensitivity and specificity of FCM were respectively 0.56 +/- 0.17 (m +/- SD) and 1.0 +/- 0.0 for the detection of dust mite-activated basophils without IL-3 preincubation, and 0.73 +/- 0.13 and 1.0 +/- 0.0 for the detention of grass pollen-activated basophils. IL-3-preincubation increased the sensitivity in a dose-dependent manner but decreased the specificity fo FCM for detecting dust mite hypersensitivity. this method allow for rapid and easy detection of activated basophils from whole blood, and could be of interest for detecting allergies to non-conventional allergens such as pharmaceutical drugs.
NASA Technical Reports Server (NTRS)
Telford, W. G.; Cox, W. G.; Stiner, D.; Singer, V. L.; Doty, S. B.
1999-01-01
BACKGROUND: The alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazolinone (ELF((R))-97 for enzyme-labeled fluorescence) has been found useful for the histochemical detection of endogenous AP activity and AP-tagged proteins and oligonucleotide probes. In this study, we evaluated its effectiveness at detecting endogenous AP activity by flow cytometry. METHODS: The ELF-97 phosphatase substrate was used to detect endogenous AP activity in UMR-106 rat osteosarcoma cells and primary cultures of chick chondrocytes. Cells were labeled with the ELF-97 reagent and analyzed by flow cytometry using an argon ultraviolet (UV) laser. For comparison purposes, cells were also assayed for AP using a Fast Red Violet LB azo dye assay previously described for use in detecting AP activity by flow cytometry. RESULTS: The ELF-97 phosphatase substrate effectively detected endogenous AP activity in UMR-106 cells, with over 95% of the resulting fluorescent signal resulting from AP-specific activity (as determined by levamisole inhibition of AP activity). In contrast, less than 70% of the fluorescent signal from the Fast Red Violet LB (FRV) assay was AP-dependent, reflecting the high intrinsic fluorescence of the unreacted components. The ELF-97 phosphatase assay was also able to detect very low AP activity in chick chondrocytes that was undetectable by the azo dye method. CONCLUSIONS: The ELF-97 phosphatase assay was able to detect endogenous AP activity in fixed mammalian and avian cells by flow cytometry with superior sensitivity to previously described assays. This work also shows the applicability of ELF-97 to flow cytometry, supplementing its previously demonstrated histochemical applications. Copyright 1999 Wiley-Liss, Inc.
The level of sugars and synthesis of trehalose in Ascaris suum tissues.
Dmitryjuk, M; Łopieńska-Biernat, E; Farjan, M
2009-09-01
The activities of trehalose-6-phosphate synthase (TPS) and trehalose-6-phosphate phosphatase (TPP) were observed in muscles, individual parts of the reproductive system and haemolymph of Ascaris suum. The highest activity of TPS was detected in the upper uterus, while the lowest activity of TPS was detected in the ovary and oviduct of the nematode. Relatively high activity was detected in muscles, haemolymph and two remaining parts of the uterus. The TPP activity was the highest in lower length of the uterus, following muscles, ovary, central and upper uterus. The lowest activity of TPP was detected in the haemolymph and oviduct of A. suum. Besides TPS and TPP, trehalose was also detected in the studied tissues except the cuticle and the intestine. Glucose was present in all organs, but the highest concentration was found in the cuticle and intestine.
Active Detection for Exposing Intelligent Attacks in Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weerakkody, Sean; Ozel, Omur; Griffioen, Paul
In this paper, we consider approaches for detecting integrity attacks carried out by intelligent and resourceful adversaries in control systems. Passive detection techniques are often incorporated to identify malicious behavior. Here, the defender utilizes finely-tuned algorithms to process information and make a binary decision, whether the system is healthy or under attack. We demonstrate that passive detection can be ineffective against adversaries with model knowledge and access to a set of input/output channels. We then propose active detection as a tool to detect attacks. In active detection, the defender leverages degrees of freedom he has in the system to detectmore » the adversary. Specifically, the defender will introduce a physical secret kept hidden from the adversary, which can be utilized to authenticate the dynamics. In this regard, we carefully review two approaches for active detection: physical watermarking at the control input, and a moving target approach for generating system dynamics. We examine practical considerations for implementing these technologies and discuss future research directions.« less
Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David
Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.
Mazerolle, Erin L; D'Arcy, Ryan CN; Beyea, Steven D
2008-01-01
Background It is generally believed that activation in functional magnetic resonance imaging (fMRI) is restricted to gray matter. Despite this, a number of studies have reported white matter activation, particularly when the corpus callosum is targeted using interhemispheric transfer tasks. These findings suggest that fMRI signals may not be neatly confined to gray matter tissue. In the current experiment, 4 T fMRI was employed to evaluate whether it is possible to detect white matter activation. We used an interhemispheric transfer task modelled after neurological studies of callosal disconnection. It was hypothesized that white matter activation could be detected using fMRI. Results Both group and individual data were considered. At liberal statistical thresholds (p < 0.005, uncorrected), group level activation was detected in the isthmus of the corpus callosum. This region connects the superior parietal cortices, which have been implicated previously in interhemispheric transfer. At the individual level, five of the 24 subjects (21%) had activation clusters that were located primarily within the corpus callosum. Consistent with the group results, the clusters of all five subjects were located in posterior callosal regions. The signal time courses for these clusters were comparable to those observed for task related gray matter activation. Conclusion The findings support the idea that, despite the inherent challenges, fMRI activation can be detected in the corpus callosum at the individual level. Future work is needed to determine whether the detection of this activation can be improved by utilizing higher spatial resolution, optimizing acquisition parameters, and analyzing the data with tissue specific models of the hemodynamic response. The ability to detect white matter fMRI activation expands the scope of basic and clinical brain mapping research, and provides a new approach for understanding brain connectivity. PMID:18789154
The detection of intestinal spike activity on surface electroenterograms
NASA Astrophysics Data System (ADS)
Ye-Lin, Y.; Garcia-Casado, J.; Martinez-de-Juan, J. L.; Prats-Boluda, G.; Ponce, J. L.
2010-02-01
Myoelectrical recording could provide an alternative technique for assessing intestinal motility, which is a topic of great interest in gastroenterology since many gastrointestinal disorders are associated with intestinal dysmotility. The pacemaker activity (slow wave, SW) of the electroenterogram (EEnG) has been detected in abdominal surface recordings, although the activity related to bowel contractions (spike bursts, SB) has to date only been detected in experimental models with artificially favored electrical conductivity. The aim of the present work was to assess the possibility of detecting SB activity in abdominal surface recordings under physiological conditions. For this purpose, 11 recording sessions of simultaneous internal and external myolectrical signals were conducted on conscious dogs. Signal analysis was carried out in the spectral domain. The results show that in periods of intestinal contractile activity, high-frequency components of EEnG signals can be detected on the abdominal surface in addition to SW activity. The energy between 2 and 20 Hz of the surface myoelectrical recording presented good correlation with the internal intestinal motility index (0.64 ± 0.10 for channel 1 and 0.57 ± 0.11 for channel 2). This suggests that SB activity can also be detected in canine surface EEnG recording.
Activity Tracking for Pilot Error Detection from Flight Data
NASA Technical Reports Server (NTRS)
Callantine, Todd J.; Ashford, Rose (Technical Monitor)
2002-01-01
This report presents an application of activity tracking for pilot error detection from flight data, and describes issues surrounding such an application. It first describes the Crew Activity Tracking System (CATS), in-flight data collected from the NASA Langley Boeing 757 Airborne Research Integrated Experiment System aircraft, and a model of B757 flight crew activities. It then presents an example of CATS detecting actual in-flight crew errors.
Attachment of second harmonic-active moiety to molecules for detection of molecules at interfaces
Salafsky, Joshua S.; Eisenthal, Kenneth B.
2005-10-11
This invention provides methods of detecting molecules at an interface, which comprise labeling the molecules with a second harmonic-active moiety and detecting the labeled molecules at the interface using a surface selective technique. The invention also provides methods for detecting a molecule in a medium and for determining the orientation of a molecular species within a planar surface using a second harmonic-active moiety and a surface selective technique.
Vallabani, N V Srikanth; Karakoti, Ajay S; Singh, Sanjay
2017-05-01
Fe 3 O 4 nanoparticles (Fe 3 O 4 NPs), demonstrating peroxidase-like activity has garnered attention in the detection of several biomolecules, therefore, emerged as an excellent nano-biosensing agent. The intrinsic peroxidase-like activity of Fe 3 O 4 NPs at acidic pH is the fundamental action driving the oxidation of substrates like TMB, resulting in a colorimetric product formation used in the detection of biomolecules. Hence, the detection sensitivity essentially depends on the ability of oxidation by Fe 3 O 4 NPs in presence of H 2 O 2 . However, the limited sensitivity and pH condition constraint have been identified as the major drawbacks in the detection of biomolecules at physiological pH. Herein, we report overwhelming of the fundamental limitation of acidic pH and tuning the peroxidase-like activity of Fe 3 O 4 NPs at physiological pH by using ATP. In presence of ATP, Fe 3 O 4 NPs exhibited enhanced peroxidase-like activity over a wide range of pH and temperatures. Mechanistically, it was found that the ability of ATP to participate in single electron transfer reaction, through complexation with Fe 3 O 4 NPs, results in the generation of hydroxyl radicals which are responsible for enhanced peroxidase activity at physiological pH. We utilized this ATP-mediated enhanced peroxidase-like activity of Fe 3 O 4 NPs for single step detection of glucose with a colorimetric detection limit of 50μM. Further, we extended this single step detection method to monitor glucose level in human blood serum and detected in a time span of <5min at pH 7.4. Copyright © 2017 Elsevier B.V. All rights reserved.
Alves, Natasha; Chau, Tom
2010-04-01
Knowledge of muscle activity timing is critical to many clinical applications, such as the assessment of muscle coordination and the prescription of muscle-activated switches for individuals with disabilities. In this study, we introduce a continuous wavelet transform (CWT) algorithm for the detection of muscle activity via mechanomyogram (MMG) signals. CWT coefficients of the MMG signal were compared to scale-specific thresholds derived from the baseline signal to estimate the timing of muscle activity. Test signals were recorded from the flexor carpi radialis muscles of 15 able-bodied participants as they squeezed and released a hand dynamometer. Using the dynamometer signal as a reference, the proposed CWT detection algorithm was compared against a global-threshold CWT detector as well as amplitude-based event detection for sensitivity and specificity to voluntary contractions. The scale-specific CWT-based algorithm exhibited superior detection performance over the other detectors. CWT detection also showed good muscle selectivity during hand movement, particularly when a given muscle was the primary facilitator of the contraction. This may suggest that, during contraction, the compound MMG signal has a recurring morphological pattern that is not prevalent in the baseline signal. The ability of CWT analysis to be implemented in real time makes it a candidate for muscle-activity detection in clinical applications.
2015-09-01
intrusion detection systems , neural networks 15. NUMBER OF PAGES 75 16. PRICE CODE 17. SECURITY CLASSIFICATION OF... detection system (IDS) software, which learns to detect and classify network attacks and intrusions through prior training data. With the added criteria of...BACKGROUND The growing threat of malicious network activities and intrusion attempts makes intrusion detection systems (IDS) a
UHF wearable battery free sensor module for activity and falling detection.
Nam Trung Dang; Thang Viet Tran; Wan-Young Chung
2016-08-01
Falling is one of the most serious medical and social problems in aging population. Therefore taking care of the elderly by detecting activity and falling for preventing and mitigating the injuries caused by falls needs to be concerned. This study proposes a wearable, wireless, battery free ultra-high frequency (UHF) smart sensor tag module for falling and activity detection. The proposed tag is powered by UHF RF wave from reader and read by a standard UHF Electronic Product Code (EPC) Class-1 Generation-2 reader. The battery free sensor module could improve the wearability of the wireless device. The combination of accelerometer signal and received signal strength indication (RSSI) from a reader in the passive smart sensor tag detect the activity and falling of the elderly very successfully. The fabricated smart sensor tag module has an operating range of up to 2.5m and conducting in real-time activity and falling detection.
Worrell, V E; Nagle, D P
1990-01-01
The enzymes involved in the purine interconversion pathway of wild-type and purine analog-resistant strains of Methanobacterium thermoautotrophicum Marburg were assayed by radiometric and spectrophotometric methods. Wild-type cells incorporated labeled adenine, guanine, and hypoxanthine, whereas mutant strains varied in their ability to incorporate these bases. Adenine, guanine, hypoxanthine, and xanthine were activated by phosphoribosyltransferase activities present in wild-type cell extracts. Some mutant strains simultaneously lost the ability to convert both guanine and hypoxanthine to the respective nucleotide, suggesting that the same enzyme activates both bases. Adenosine, guanosine, and inosine phosphorylase activities were detected for the conversion of base to nucleoside. Adenine deaminase activity was detected at low levels. Guanine deaminase activity was not detected. Nucleoside kinase activities for the conversion of adenosine, guanosine, and inosine to the respective nucleotides were detected by a new assay. The nucleotide-interconverting enzymes AMP deaminase, succinyl-AMP synthetase, succinyl-AMP lyase, IMP dehydrogenase, and GMP synthetase were present in extracts; GMP reductase was not detected. The results indicate that this autotrophic methanogen has a complex system for the utilization of exogenous purines. PMID:2345148
NASA Technical Reports Server (NTRS)
Buehler, Martin (Inventor)
2009-01-01
An electro-active sensor includes a nonconductive platform with a first electrode set attached with a first side of a nonconductive platform. The first electrode set serves as an electrochemical cell that may be utilized to detect electro-active species in solution. A plurality of electrode sets and a variety of additional electrochemical cells and sensors may be attached with the nonconductive platform. The present invention also includes a method for constructing the aforementioned electro-active sensor. Additionally, an apparatus for detection and observation is disclosed, where the apparatus includes a sealable chamber for insertion of a portion of an electro-active sensor. The apparatus allows for monitoring and detection activities. Allowing for control of attached cells and sensors, a dual-mode circuitry is also disclosed. The dual-mode circuitry includes a switch, allowing the circuitry to be switched from a potentiostat to a galvanostat mode.
A novel approach for reliable detection of cathepsin S activities in mouse antigen presenting cells.
Steimle, Alex; Kalbacher, Hubert; Maurer, Andreas; Beifuss, Brigitte; Bender, Annika; Schäfer, Andrea; Müller, Ricarda; Autenrieth, Ingo B; Frick, Julia-Stefanie
2016-05-01
Cathepsin S (CTSS) is a eukaryotic protease mostly expressed in professional antigen presenting cells (APCs). Since CTSS activity regulation plays a role in the pathogenesis of various autoimmune diseases like multiple sclerosis, atherosclerosis, Sjögren's syndrome and psoriasis as well as in cancer progression, there is an ongoing interest in the reliable detection of cathepsin S activity. Various applications have been invented for specific detection of this enzyme. However, most of them have only been shown to be suitable for human samples, do not deliver quantitative results or the experimental procedure requires technical equipment that is not commonly available in a standard laboratory. We have tested a fluorogen substrate, Mca-GRWPPMGLPWE-Lys(Dnp)-DArg-NH2, that has been described to specifically detect CTSS activities in human APCs for its potential use for mouse samples. We have modified the protocol and thereby offer a cheap, easy, reproducible and quick activity assay to detect CTSS activities in mouse APCs. Since most of basic research on CTSS is performed in mice, this method closes a gap and offers a possibility for reliable and quantitative CTSS activity detection that can be performed in almost every laboratory. Copyright © 2016. Published by Elsevier B.V.
Real-time Human Activity Recognition
NASA Astrophysics Data System (ADS)
Albukhary, N.; Mustafah, Y. M.
2017-11-01
The traditional Closed-circuit Television (CCTV) system requires human to monitor the CCTV for 24/7 which is inefficient and costly. Therefore, there’s a need for a system which can recognize human activity effectively in real-time. This paper concentrates on recognizing simple activity such as walking, running, sitting, standing and landing by using image processing techniques. Firstly, object detection is done by using background subtraction to detect moving object. Then, object tracking and object classification are constructed so that different person can be differentiated by using feature detection. Geometrical attributes of tracked object, which are centroid and aspect ratio of identified tracked are manipulated so that simple activity can be detected.
Adewole, Olanisun Olufemi; Erhabor, Greg Efosa; Adewole, Temitayo Oluwatoyin; Ojo, Abiodun Oluwasesan; Oshokoya, Harriet; Wolfe, Lisa M; Prenni, Jessica E
2016-05-01
Excessive sweating is a common symptom of the disease and an unexplored biofluid for TB diagnosis; we conducted a proof-of-concept study to identify potential diagnostic biomarkers of active TB in eccrine sweat. We performed a global proteomic profile of eccrine sweat sampled from patients with active pulmonary TB, other lung diseases (non-TB disease), and healthy controls. A comparison of proteomics between Active-TB, Non-TB, and Healthy Controls was done in search for potential biomarkers of active TB. Sweat specimens were pooled from 32 active TB patients, 27 patients with non-TB diseases, and 24 apparently healthy controls, all were negative for HIV. Over 100 unique proteins were identified in the eccrine sweat of all three groups. Twenty-six proteins were exclusively detected in the sweat of patients with active TB while the remaining detected proteins overlapped between three groups. Gene ontology evaluation indicated that the proteins detected uniquely in sweat of active TB patients were involved in immune response and auxiliary protein transport. Gene products for cellular components (e.g. ribosomes) were detected only in active TB patients. Data are available via ProteomeXchange with identifier PXD003224. Proteomics of sweat from active TB patients is a viable approach for biomarker identification, which could be used to develop a nonsputum-based test for detection of active TB. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lingual lipase activity in the orosensory detection of fat by humans
Kulkarni, Bhushan V.
2014-01-01
Lingual lipase generates nonesterified fatty acids (NEFA) from dietary fats during oral processing by lipolysis. Lingual lipase in rodents has strong lipolytic activity and plays a critical role in oral detection of fats. The functional activity of lingual lipase during oral processing of high-fat foods in humans remains poorly characterized. Five commonly consumed high-fat foods varying in physical states and fatty acid composition (almond, almond butter, olive oil, walnut, and coconut) were masticated by 15 healthy human subjects at the rate of one chew per second with and without lipase inhibitor orlistat. Salivary NEFA concentrations were measured. To determine the role of lingual lipase in oral fat detection, sensory ratings were obtained from the same 15 human subjects for almond butter with and without orlistat. Lingual lipase was active during oral processing of almond and coconut. No activity of lingual lipase was detected during processing of almond butter. There was only weak evidence lingual lipase is a determinant of oral fat detection. Lingual lipase may only contribute to NEFA generation and oral fat detection of fatty foods that require stronger oral processing effort. PMID:24694384
Caldera unrest detected with seawater temperature anomalies at Deception Island, Antarctic Peninsula
NASA Astrophysics Data System (ADS)
Berrocoso, M.; Prates, G.; Fernández-Ros, A.; Peci, L. M.; de Gil, A.; Rosado, B.; Páez, R.; Jigena, B.
2018-04-01
Increased thermal activity was detected to coincide with the onset of volcano inflation in the seawater-filled caldera at Deception Island. This thermal activity was manifested in pulses of high water temperature that coincided with ocean tide cycles. The seawater temperature anomalies were detected by a thermometric sensor attached to the tide gauge (bottom pressure sensor). This was installed where the seawater circulation and the locations of known thermal anomalies, fumaroles and thermal springs, together favor the detection of water warmed within the caldera. Detection of the increased thermal activity was also possible because sea ice, which covers the entire caldera during the austral winter months, insulates the water and thus reduces temperature exchange between seawater and atmosphere. In these conditions, the water temperature data has been shown to provide significant information about Deception volcano activity. The detected seawater temperature increase, also observed in soil temperature readings, suggests rapid and near-simultaneous increase in geothermal activity with onset of caldera inflation and an increased number of seismic events observed in the following austral summer.
[Detection of Physiological Activity of Pharmaceuticals in Wastewater and River Water].
Ihara, Masaru; Zhang, Han; Hanamoto, Seiya; Tanaka, Hiroaki
2018-01-01
Pharmaceuticals are widely found in aquatic environments worldwide. Concern about their potential risks to aquatic species has been raised because they are designed to be biologically active. To address this concern, we must know whether biological activity of pharmaceuticals can be detected in waters. Nearly half of all marketed pharmaceuticals act by binding to the G protein-coupled receptor (GPCR). In this study, we measured the physiological activity of GPCR-acting pharmaceuticals in effluent from a wastewater treatment plant (WWTP) and upstream and downstream of its outfall in Japan during 2 years. We used the in vitro transforming growth factor-α (TGFα) shedding assay, which accurately and sensitively detects GPCR activation, to investigate the antagonistic activities of water extracts against receptors for dopamine (D2) and histamine (H1). Activities detected in waters were quantified as antagonist equivalent quantities (EQs). In WWTP effluent extracts, antagonistic activity was detected at several hundred ng/L of sulpiride-EQ (D2) and several μg/L of diphenhydramine (DIP)-EQ (H1). In downstream river water extracts, antagonistic activity against H1 was around several hundred ng/L of DIP-EQ, higher than that upstream owing to the WWTP effluent. This review discusses the research needed to resolve the concern about potential risks of pharmaceuticals in waters to aquatic species.
Natural and anthropogenic radionuclide activity concentrations in the New Zealand diet.
Pearson, Andrew J; Gaw, Sally; Hermanspahn, Nikolaus; Glover, Chris N
2016-01-01
To support New Zealand's food safety monitoring regime, a survey was undertaken to establish radionuclide activity concentrations across the New Zealand diet. This survey was undertaken to better understand the radioactivity content of the modern diet and also to assess the suitability of the current use of milk as a sentinel for dietary radionuclide trends. Thirteen radionuclides were analysed in 40 common food commodities, including animal products, fruits, vegetables, cereal grains and seafood. Activity was detected for (137)Caesium, (90)Strontium and (131)Iodine. No other anthropogenic radionuclides were detected. Activity concentrations of the three natural radionuclides of Uranium and the daughter radionuclide (210)Polonium were detected in the majority of food sampled, with a large variation in magnitude. The maximum activity concentrations were detected in shellfish for all these radionuclides. Based on the established activity concentrations and ranges, the New Zealand diet contains activity concentrations of anthropogenic radionuclides far below the Codex Alimentarius guideline levels. Activity concentrations obtained for milk support its continued use as a sentinel for monitoring fallout radionuclides in terrestrial agriculture. The significant levels of natural and anthropogenic radionuclide activity concentrations detected in finfish and molluscs support undertaking further research to identify a suitable sentinel for New Zealand seafood monitoring. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sniper detection using infrared camera: technical possibilities and limitations
NASA Astrophysics Data System (ADS)
Kastek, M.; Dulski, R.; Trzaskawka, P.; Bieszczad, G.
2010-04-01
The paper discusses technical possibilities to build an effective system for sniper detection using infrared cameras. Descriptions of phenomena which make it possible to detect sniper activities in infrared spectra as well as analysis of physical limitations were performed. Cooled and uncooled detectors were considered. Three phases of sniper activities were taken into consideration: before, during and after the shot. On the basis of experimental data the parameters defining the target were determined which are essential in assessing the capability of infrared camera to detect sniper activity. A sniper body and muzzle flash were analyzed as targets. The simulation of detection ranges was done for the assumed scenario of sniper detection task. The infrared sniper detection system was discussed, capable of fulfilling the requirements. The discussion of the results of analysis and simulations was finally presented.
Ricin detection: tracking active toxin.
Bozza, William P; Tolleson, William H; Rivera Rosado, Leslie A; Zhang, Baolin
2015-01-01
Ricin is a plant toxin with high bioterrorism potential due to its natural abundance and potency in inducing cell death. Early detection of the active toxin is essential for developing appropriate countermeasures. Here we review concepts for designing ricin detection methods, including mechanism of action of the toxin, advantages and disadvantages of current detection assays, and perspectives on the future development of rapid and reliable methods for detecting ricin in environmental samples. Published by Elsevier Inc.
Detection of protease and protease activity using a single nanoscrescent SERS probe
Liu, Gang L.; Ellman, Jonathan A.; Lee, Luke P.; Chen, Fanqing Frank
2013-01-29
This invention pertains to the in vitro detection of proteases using a single peptide-conjugate nanocrescent surface enhanced Raman scattering (SERS) probes with at least nanomolar sensitivity. The probe enables detection of proteolytic activity in extremely small volume and at low concentration. In certain embodiments the probes comprise an indicator for the detection of an active protease, where the indicator comprises a nanocrescent attached to a peptide, where said peptide comprises a recognition site for the protease and a Raman tag attached to the peptide.
Detection of protease and protease activity using a single nanocrescent SERS probe
Liu, Gang L.; Ellman, Jonathan A.; Lee, Luke P.; Chen, Fanqing Frank
2015-09-29
This invention pertains to the in vitro detection of proteases using a single peptide-conjugate nanocrescent surface enhanced Raman scattering (SERS) probes with at least nanomolar sensitivity. The probe enables detection of proteolytic activity in extremely small volume and at low concentration. In certain embodiments the probes comprise an indicator for the detection of an active protease, where the indicator comprises a nanocrescent attached to a peptide, where said peptide comprises a recognition site for the protease and a Raman tag attached to the peptide.
Noda, Takahiro; Iimure, Kazuhiko; Okamoto, Shunsuke; Saito, Akira
2017-08-01
Browning of plant tissue is generally considered attributable to enzymatic oxidation by polyphenol oxidase (PPO). Electrophoresis followed by activity staining has been used as an effective procedure to visually detect and isolate isozymes; however, it has not been applied for examination of various PPO isozymes in lettuce. Our study demonstrated that different lettuce PPO isozymes could be detected at different pH in active staining, and multiple isozymes were detected only under alkaline conditions. As a result, we concluded that activity staining with approximately pH 8 enabled to detect various PPO isozymes in lettuce. By expression analysis of the PPO isozymes after wounding, PPO isozymes that correlated with time-course of tissue browning were detected. The wound-induced PPO may play a key role in enzymatic browning.
Acoustic change detection algorithm using an FM radio
NASA Astrophysics Data System (ADS)
Goldman, Geoffrey H.; Wolfe, Owen
2012-06-01
The U.S. Army is interested in developing low-cost, low-power, non-line-of-sight sensors for monitoring human activity. One modality that is often overlooked is active acoustics using sources of opportunity such as speech or music. Active acoustics can be used to detect human activity by generating acoustic images of an area at different times, then testing for changes among the imagery. A change detection algorithm was developed to detect physical changes in a building, such as a door changing positions or a large box being moved using acoustics sources of opportunity. The algorithm is based on cross correlating the acoustic signal measured from two microphones. The performance of the algorithm was shown using data generated with a hand-held FM radio as a sound source and two microphones. The algorithm could detect a door being opened in a hallway.
Active Semi-Supervised Community Detection Based on Must-Link and Cannot-Link Constraints
Cheng, Jianjun; Leng, Mingwei; Li, Longjie; Zhou, Hanhai; Chen, Xiaoyun
2014-01-01
Community structure detection is of great importance because it can help in discovering the relationship between the function and the topology structure of a network. Many community detection algorithms have been proposed, but how to incorporate the prior knowledge in the detection process remains a challenging problem. In this paper, we propose a semi-supervised community detection algorithm, which makes full utilization of the must-link and cannot-link constraints to guide the process of community detection and thereby extracts high-quality community structures from networks. To acquire the high-quality must-link and cannot-link constraints, we also propose a semi-supervised component generation algorithm based on active learning, which actively selects nodes with maximum utility for the proposed semi-supervised community detection algorithm step by step, and then generates the must-link and cannot-link constraints by accessing a noiseless oracle. Extensive experiments were carried out, and the experimental results show that the introduction of active learning into the problem of community detection makes a success. Our proposed method can extract high-quality community structures from networks, and significantly outperforms other comparison methods. PMID:25329660
Evidential reasoning research on intrusion detection
NASA Astrophysics Data System (ADS)
Wang, Xianpei; Xu, Hua; Zheng, Sheng; Cheng, Anyu
2003-09-01
In this paper, we mainly aim at D-S theory of evidence and the network intrusion detection these two fields. It discusses the method how to apply this probable reasoning as an AI technology to the Intrusion Detection System (IDS). This paper establishes the application model, describes the new mechanism of reasoning and decision-making and analyses how to implement the model based on the synscan activities detection on the network. The results suggest that if only rational probability values were assigned at the beginning, the engine can, according to the rules of evidence combination and hierarchical reasoning, compute the values of belief and finally inform the administrators of the qualities of the traced activities -- intrusions, normal activities or abnormal activities.
Guaiacol peroxidase zymography for the undergraduate laboratory.
Wilkesman, Jeff; Castro, Diana; Contreras, Lellys M; Kurz, Liliana
2014-01-01
This laboratory exercise presents a novel way to introduce undergraduate students to the specific detection of enzymatic activity by electrophoresis. First, students prepare a crude peroxidase extract and then analyze the homogenate via electrophoresis. Zymography, that is, a SDS-PAGE method to detect enzyme activity, is used to specifically detect peroxidase activity and furthermore, to analyze the total protein profile. After the assay, students may estimate the apparent molecular mass of the enzyme and discuss its structure. After the 4-h experiment, students gain knowledge concerning biological sample preparation, gel preparation, electrophoresis, and the importance of specific staining procedures for the detection of enzymatic activity. Copyright © 2014 The International Union of Biochemistry and Molecular Biology.
NASA Astrophysics Data System (ADS)
Zeng, Qingtian; Liu, Cong; Duan, Hua
2016-09-01
Correctness of an emergency response process specification is critical to emergency mission success. Therefore, errors in the specification should be detected and corrected at build-time. In this paper, we propose a resource conflict detection approach and removal strategy for emergency response processes constrained by resources and time. In this kind of emergency response process, there are two timing functions representing the minimum and maximum execution time for each activity, respectively, and many activities require resources to be executed. Based on the RT_ERP_Net, the earliest time to start each activity and the ideal execution time of the process can be obtained. To detect and remove the resource conflicts in the process, the conflict detection algorithms and a priority-activity-first resolution strategy are given. In this way, real execution time for each activity is obtained and a conflict-free RT_ERP_Net is constructed by adding virtual activities. By experiments, it is proved that the resolution strategy proposed can shorten the execution time of the whole process to a great degree.
Capturing and Displaying Uncertainty in the Common Tactical/Environmental Picture
2003-09-30
multistatic active detection, and incorporated this characterization into a Bayesian track - before - detect system called, the Likelihood Ratio Tracker (LRT...prediction uncertainty in a track before detect system for multistatic active sonar. The approach has worked well on limited simulation data. IMPACT
Environmental DNA (eDNA) Detection Probability Is Influenced by Seasonal Activity of Organisms.
de Souza, Lesley S; Godwin, James C; Renshaw, Mark A; Larson, Eric
2016-01-01
Environmental DNA (eDNA) holds great promise for conservation applications like the monitoring of invasive or imperiled species, yet this emerging technique requires ongoing testing in order to determine the contexts over which it is effective. For example, little research to date has evaluated how seasonality of organism behavior or activity may influence detection probability of eDNA. We applied eDNA to survey for two highly imperiled species endemic to the upper Black Warrior River basin in Alabama, US: the Black Warrior Waterdog (Necturus alabamensis) and the Flattened Musk Turtle (Sternotherus depressus). Importantly, these species have contrasting patterns of seasonal activity, with N. alabamensis more active in the cool season (October-April) and S. depressus more active in the warm season (May-September). We surveyed sites historically occupied by these species across cool and warm seasons over two years with replicated eDNA water samples, which were analyzed in the laboratory using species-specific quantitative PCR (qPCR) assays. We then used occupancy estimation with detection probability modeling to evaluate both the effects of landscape attributes on organism presence and season of sampling on detection probability of eDNA. Importantly, we found that season strongly affected eDNA detection probability for both species, with N. alabamensis having higher eDNA detection probabilities during the cool season and S. depressus have higher eDNA detection probabilities during the warm season. These results illustrate the influence of organismal behavior or activity on eDNA detection in the environment and identify an important role for basic natural history in designing eDNA monitoring programs.
Zhang, Ning; Francis, Kevin P; Prakash, Arun; Ansaldi, Daniel
2013-04-01
A previous study reported the use of luminol for the detection of myeloperoxidase (MPO) activity using optical imaging in infiltrating neutrophils under inflammatory disease conditions. The detection is based on a photon-emitting reaction between luminol and an MPO metabolite. Because of tissue absorption and scattering, however, luminol-emitted blue light can be efficiently detected from superficial inflammatory foci only. In this study we report a chemiluminescence resonance energy transfer (CRET) methodology in which luminol-generated blue light excites nanoparticles to emit light in the near-infrared spectral range, resulting in remarkable improvement of MPO detectability in vivo. CRET caused a 37-fold increase in luminescence emission over luminol alone in detecting MPO activity in lung tissues after lipopolysaccharide challenge. We demonstrated a dependence of the chemiluminescent signal on MPO activity using MPO-deficient mice. In addition, co-administration of 4-aminobenzoic acid hydrazide (4-ABAH), an irreversible inhibitor of MPO, significantly attenuated luminescent emission from inflamed lungs. Inhibition of nitric oxide synthase with a nonspecific inhibitor, L-NAME, had no effect on luminol-mediated chemiluminescence production. Pretreatment of mice with MLN120B, a selective inhibitor of IKK-2, resulted in suppression of neutrophil infiltration to the lung tissues and reduction of MPO activity. We also demonstrated that CRET can effectively detect MPO activity at deep tissue tumor foci due to tumor development-associated neutrophil infiltration. We developed a sensitive MPO detection methodology that provides a means for visualizing and quantifying oxidative stress in deep tissue. This method is amenable to rapid evaluation of anti-inflammatory agents in animal models.
Environmental DNA (eDNA) Detection Probability Is Influenced by Seasonal Activity of Organisms
de Souza, Lesley S.; Godwin, James C.; Renshaw, Mark A.; Larson, Eric
2016-01-01
Environmental DNA (eDNA) holds great promise for conservation applications like the monitoring of invasive or imperiled species, yet this emerging technique requires ongoing testing in order to determine the contexts over which it is effective. For example, little research to date has evaluated how seasonality of organism behavior or activity may influence detection probability of eDNA. We applied eDNA to survey for two highly imperiled species endemic to the upper Black Warrior River basin in Alabama, US: the Black Warrior Waterdog (Necturus alabamensis) and the Flattened Musk Turtle (Sternotherus depressus). Importantly, these species have contrasting patterns of seasonal activity, with N. alabamensis more active in the cool season (October-April) and S. depressus more active in the warm season (May-September). We surveyed sites historically occupied by these species across cool and warm seasons over two years with replicated eDNA water samples, which were analyzed in the laboratory using species-specific quantitative PCR (qPCR) assays. We then used occupancy estimation with detection probability modeling to evaluate both the effects of landscape attributes on organism presence and season of sampling on detection probability of eDNA. Importantly, we found that season strongly affected eDNA detection probability for both species, with N. alabamensis having higher eDNA detection probabilities during the cool season and S. depressus have higher eDNA detection probabilities during the warm season. These results illustrate the influence of organismal behavior or activity on eDNA detection in the environment and identify an important role for basic natural history in designing eDNA monitoring programs. PMID:27776150
Xi, Xugang; Tang, Minyan; Miran, Seyed M; Luo, Zhizeng
2017-05-27
As an essential subfield of context awareness, activity awareness, especially daily activity monitoring and fall detection, plays a significant role for elderly or frail people who need assistance in their daily activities. This study investigates the feature extraction and pattern recognition of surface electromyography (sEMG), with the purpose of determining the best features and classifiers of sEMG for daily living activities monitoring and fall detection. This is done by a serial of experiments. In the experiments, four channels of sEMG signal from wireless, wearable sensors located on lower limbs are recorded from three subjects while they perform seven activities of daily living (ADL). A simulated trip fall scenario is also considered with a custom-made device attached to the ankle. With this experimental setting, 15 feature extraction methods of sEMG, including time, frequency, time/frequency domain and entropy, are analyzed based on class separability and calculation complexity, and five classification methods, each with 15 features, are estimated with respect to the accuracy rate of recognition and calculation complexity for activity monitoring and fall detection. It is shown that a high accuracy rate of recognition and a minimal calculation time for daily activity monitoring and fall detection can be achieved in the current experimental setting. Specifically, the Wilson Amplitude (WAMP) feature performs the best, and the classifier Gaussian Kernel Support Vector Machine (GK-SVM) with Permutation Entropy (PE) or WAMP results in the highest accuracy for activity monitoring with recognition rates of 97.35% and 96.43%. For fall detection, the classifier Fuzzy Min-Max Neural Network (FMMNN) has the best sensitivity and specificity at the cost of the longest calculation time, while the classifier Gaussian Kernel Fisher Linear Discriminant Analysis (GK-FDA) with the feature WAMP guarantees a high sensitivity (98.70%) and specificity (98.59%) with a short calculation time (65.586 ms), making it a possible choice for pre-impact fall detection. The thorough quantitative comparison of the features and classifiers in this study supports the feasibility of a wireless, wearable sEMG sensor system for automatic activity monitoring and fall detection.
Xi, Xugang; Tang, Minyan; Miran, Seyed M.; Luo, Zhizeng
2017-01-01
As an essential subfield of context awareness, activity awareness, especially daily activity monitoring and fall detection, plays a significant role for elderly or frail people who need assistance in their daily activities. This study investigates the feature extraction and pattern recognition of surface electromyography (sEMG), with the purpose of determining the best features and classifiers of sEMG for daily living activities monitoring and fall detection. This is done by a serial of experiments. In the experiments, four channels of sEMG signal from wireless, wearable sensors located on lower limbs are recorded from three subjects while they perform seven activities of daily living (ADL). A simulated trip fall scenario is also considered with a custom-made device attached to the ankle. With this experimental setting, 15 feature extraction methods of sEMG, including time, frequency, time/frequency domain and entropy, are analyzed based on class separability and calculation complexity, and five classification methods, each with 15 features, are estimated with respect to the accuracy rate of recognition and calculation complexity for activity monitoring and fall detection. It is shown that a high accuracy rate of recognition and a minimal calculation time for daily activity monitoring and fall detection can be achieved in the current experimental setting. Specifically, the Wilson Amplitude (WAMP) feature performs the best, and the classifier Gaussian Kernel Support Vector Machine (GK-SVM) with Permutation Entropy (PE) or WAMP results in the highest accuracy for activity monitoring with recognition rates of 97.35% and 96.43%. For fall detection, the classifier Fuzzy Min-Max Neural Network (FMMNN) has the best sensitivity and specificity at the cost of the longest calculation time, while the classifier Gaussian Kernel Fisher Linear Discriminant Analysis (GK-FDA) with the feature WAMP guarantees a high sensitivity (98.70%) and specificity (98.59%) with a short calculation time (65.586 ms), making it a possible choice for pre-impact fall detection. The thorough quantitative comparison of the features and classifiers in this study supports the feasibility of a wireless, wearable sEMG sensor system for automatic activity monitoring and fall detection. PMID:28555016
Subsurface Intrusion Detection System
2014-02-25
deployed along the boundary. The outputs of the vibration sensors are taken as an indication of underground activity and can therefore be used to...for detecting underground activity. The system has a first sensor located at a first depth below the surface of the ground and a second sensor...and the second sensor has a second output indicative of vibrations at the second depth. A processor adapted to detect underground activity compares
Research on the system scheme and experiment for the active laser polarization imaging
NASA Astrophysics Data System (ADS)
Fu, Qiang; Duan, Jin; Zhao, Rui; Li, Zheng; Zhang, Su; Zhan, Juntong; Zhu, Yong; Jiang, Hui-Lin
2015-10-01
The polarization imaging detection technology increased the polarization information on the basis of the intensity imaging, which is extensive application in the military and civil and other fields. The research present and development trend of polarization imaging detection technology was introduce, the system scheme of the active polarization imaging detection was put forward, and the key technologies such as the polarization information detection, optical system design, polarization radiation calibration and image fusion approach was analyzed. On this basis, detection system by existing equipment of laboratory was set up, and on the different materials such as wood, metal, plastic and goal was detected by polarization imaging to realize the active polarization imaging detection. The results show that image contrast of the metal and man-made objects is higher, the polarization effect is better, which provided the basis on the better performance of the polarization imaging instruments.
Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.
Nakayama, Shinsuke; Sawamura, Kenta; Mohri, Kaneo; Uchiyama, Tsuyoshi
2011-01-01
This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.
Modeling Patterns of Activities using Activity Curves
Dawadi, Prafulla N.; Cook, Diane J.; Schmitter-Edgecombe, Maureen
2016-01-01
Pervasive computing offers an unprecedented opportunity to unobtrusively monitor behavior and use the large amount of collected data to perform analysis of activity-based behavioral patterns. In this paper, we introduce the notion of an activity curve, which represents an abstraction of an individual’s normal daily routine based on automatically-recognized activities. We propose methods to detect changes in behavioral routines by comparing activity curves and use these changes to analyze the possibility of changes in cognitive or physical health. We demonstrate our model and evaluate our change detection approach using a longitudinal smart home sensor dataset collected from 18 smart homes with older adult residents. Finally, we demonstrate how big data-based pervasive analytics such as activity curve-based change detection can be used to perform functional health assessment. Our evaluation indicates that correlations do exist between behavior and health changes and that these changes can be automatically detected using smart homes, machine learning, and big data-based pervasive analytics. PMID:27346990
Modeling Patterns of Activities using Activity Curves.
Dawadi, Prafulla N; Cook, Diane J; Schmitter-Edgecombe, Maureen
2016-06-01
Pervasive computing offers an unprecedented opportunity to unobtrusively monitor behavior and use the large amount of collected data to perform analysis of activity-based behavioral patterns. In this paper, we introduce the notion of an activity curve , which represents an abstraction of an individual's normal daily routine based on automatically-recognized activities. We propose methods to detect changes in behavioral routines by comparing activity curves and use these changes to analyze the possibility of changes in cognitive or physical health. We demonstrate our model and evaluate our change detection approach using a longitudinal smart home sensor dataset collected from 18 smart homes with older adult residents. Finally, we demonstrate how big data-based pervasive analytics such as activity curve-based change detection can be used to perform functional health assessment. Our evaluation indicates that correlations do exist between behavior and health changes and that these changes can be automatically detected using smart homes, machine learning, and big data-based pervasive analytics.
A Novel In-Beam Delayed Neutron Counting Technique for Characterization of Special Nuclear Materials
NASA Astrophysics Data System (ADS)
Bentoumi, G.; Rogge, R. B.; Andrews, M. T.; Corcoran, E. C.; Dimayuga, I.; Kelly, D. G.; Li, L.; Sur, B.
2016-12-01
A delayed neutron counting (DNC) system, where the sample to be analyzed remains stationary in a thermal neutron beam outside of the reactor, has been developed at the National Research Universal (NRU) reactor of the Canadian Nuclear Laboratories (CNL) at Chalk River. The new in-beam DNC is a novel approach for non-destructive characterization of special nuclear materials (SNM) that could enable identification and quantification of fissile isotopes within a large and shielded sample. Despite the orders of magnitude reduction in neutron flux, the in-beam DNC method can be as informative as the conventional in-core DNC for most cases while offering practical advantages and mitigated risk when dealing with large radioactive samples of unknown origin. This paper addresses (1) the qualification of in-beam DNC using a monochromatic thermal neutron beam in conjunction with a proven counting apparatus designed originally for in-core DNC, and (2) application of in-beam DNC to an examination of large sealed capsules containing unknown radioactive materials. Initial results showed that the in-beam DNC setup permits non-destructive analysis of bulky and gamma shielded samples. The method does not lend itself to trace analysis, and at best could only reveal the presence of a few milligrams of 235U via the assay of in-beam DNC total counts. Through analysis of DNC count rates, the technique could be used in combination with other neutron or gamma techniques to quantify isotopes present within samples.
Imaging of Nuclear Weapon Trainers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwellenbach, David
2017-12-06
The Configurable Muon Tracker (CMT) is an adaptation of the existing drift tube detector commercially available from Decision Sciences International Corporation (DSIC). NSTec engineered the CMT around commercially available drift tube assemblies to make a detector that is more versatile than previous drift tube assemblies. The CMT became operational in February 2013. Traditionally, cosmic-ray muon trackers rely on near-vertical trajectory muons for imaging. Since there are scenarios where imaging using vertical trajectory muons is not practical, NSTec designed the CMT specifically for quick configurability to track muons from any trajectory. The CMT was originally designed to be changed from verticalmore » imaging mode to horizontal imaging mode in a few hours with access to a crane or other lifting equipment. In FY14, locations for imaging weapon trainers and SNM were identified and it was determined that lifting equipment would not typically be available in experimental areas. The CMT was further modified and a portable lifting system was developed to allow reconfiguration of the CMT without access to lifting equipment at the facility. This system was first deployed at Los Alamos National Laboratory’s W-division, where several trainers were imaged in both horizontal and vertical modes. Real-time images have been compared in both modes showing that imaging can be done in both modes with the expected longer integration time for horizontal mode. Further imaging and post processing of the data is expected to continue into early FY15.« less
Multilevel depth and image fusion for human activity detection.
Ni, Bingbing; Pei, Yong; Moulin, Pierre; Yan, Shuicheng
2013-10-01
Recognizing complex human activities usually requires the detection and modeling of individual visual features and the interactions between them. Current methods only rely on the visual features extracted from 2-D images, and therefore often lead to unreliable salient visual feature detection and inaccurate modeling of the interaction context between individual features. In this paper, we show that these problems can be addressed by combining data from a conventional camera and a depth sensor (e.g., Microsoft Kinect). We propose a novel complex activity recognition and localization framework that effectively fuses information from both grayscale and depth image channels at multiple levels of the video processing pipeline. In the individual visual feature detection level, depth-based filters are applied to the detected human/object rectangles to remove false detections. In the next level of interaction modeling, 3-D spatial and temporal contexts among human subjects or objects are extracted by integrating information from both grayscale and depth images. Depth information is also utilized to distinguish different types of indoor scenes. Finally, a latent structural model is developed to integrate the information from multiple levels of video processing for an activity detection. Extensive experiments on two activity recognition benchmarks (one with depth information) and a challenging grayscale + depth human activity database that contains complex interactions between human-human, human-object, and human-surroundings demonstrate the effectiveness of the proposed multilevel grayscale + depth fusion scheme. Higher recognition and localization accuracies are obtained relative to the previous methods.
2013-09-26
vehicle-lengths between frames. The low specificity of object detectors in WAMI means all vehicle detections are treated equally. Motion clutter...timing of the anomaly . If an anomaly was detected , recent activity would have a priority over older activity. This is due to the reasoning that if the...this could be a potential anomaly detected . Other baseline activities include normal work hours, religious observance times and interactions between
Top-down and bottom-up modulation of brain structures involved in auditory discrimination.
Diekhof, Esther K; Biedermann, Franziska; Ruebsamen, Rudolf; Gruber, Oliver
2009-11-10
Auditory deviancy detection comprises both automatic and voluntary processing. Here, we investigated the neural correlates of different components of the sensory discrimination process using functional magnetic resonance imaging. Subliminal auditory processing of deviant events that were not detected led to activation in left superior temporal gyrus. On the other hand, both correct detection of deviancy and false alarms activated a frontoparietal network of attentional processing and response selection, i.e. this network was activated regardless of the physical presence of deviant events. Finally, activation in the putamen, anterior cingulate and middle temporal cortex depended on factual stimulus representations and occurred only during correct deviancy detection. These results indicate that sensory discrimination may rely on dynamic bottom-up and top-down interactions.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... Information Collection Activity Under OMB Review: National Explosives Detection Canine Team Program (NEDCTP... under the National Explosives Detection Canine Team Program. The data is collected electronically... feedback to the Chief of the National Explosives Detection Canine Team Program and instructional staff and...
Leusch, Frederic D L; Aneck-Hahn, Natalie H; Cavanagh, Jo-Anne E; Du Pasquier, David; Hamers, Timo; Hebert, Armelle; Neale, Peta A; Scheurer, Marco; Simmons, Steven O; Schriks, Merijn
2018-01-01
Environmental chemicals can induce thyroid disruption through a number of mechanisms including altered thyroid hormone biosynthesis and transport, as well as activation and inhibition of the thyroid receptor. In the current study six in vitro bioassays indicative of different mechanisms of thyroid disruption and one whole animal in vivo assay were applied to 9 model compounds and 4 different water samples (treated wastewater, surface water, drinking water and ultra-pure lab water; both unspiked and spiked with model compounds) to determine their ability to detect thyroid active compounds. Most assays correctly identified and quantified the model compounds as agonists or antagonists, with the reporter gene assays being the most sensitive. However, the reporter gene assays did not detect significant thyroid activity in any of the water samples, suggesting that activation or inhibition of the thyroid hormone receptor is not a relevant mode of action for thyroid endocrine disruptors in water. The thyroperoxidase (TPO) inhibition assay and transthyretin (TTR) displacement assay (FITC) detected activity in the surface water and treated wastewater samples, but more work is required to assess if this activity is a true measure of thyroid activity or matrix interference. The whole animal Xenopus Embryonic Thyroid Assay (XETA) detected some activity in the unspiked surface water and treated wastewater extracts, but not in unspiked drinking water, and appears to be a suitable assay to detect thyroid activity in environmental waters. Copyright © 2017 Elsevier Ltd. All rights reserved.
Active Fire Mapping Program Current Large Incidents (Home) New Large Incidents Fire Detection Maps MODIS Satellite Imagery VIIRS Satellite Imagery Fire Detection GIS Data Fire Data in Google Earth ...
Sellers, Ceri; Dall, Philippa; Grant, Margaret; Stansfield, Ben
2016-01-01
Characterisation of free-living physical activity requires the use of validated and reliable monitors. This study reports an evaluation of the validity and reliability of the activPAL3 monitor for the detection of posture and stepping in both adults and young people. Twenty adults (median 27.6y; IQR22.6y) and 8 young people (12.0y; IQR4.1y) performed standardised activities and activities of daily living (ADL) incorporating sedentary, upright and stepping activity. Agreement, specificity and positive predictive value were calculated between activPAL3 outcomes and the gold-standard of video observation. Inter-device reliability was calculated between 4 monitors. Sedentary and upright times for standardised activities were within ±5% of video observation as was step count (excluding jogging) for both adults and young people. Jogging step detection accuracy reduced with increasing cadence >150stepsmin(-1). For ADLs, sensitivity to stepping was very low for adults (40.4%) but higher for young people (76.1%). Inter-device reliability was either good (ICC(1,1)>0.75) or excellent (ICC(1,1)>0.90) for all outcomes. An excellent level of detection of standardised postures was demonstrated by the activPAL3. Postures such as seat-perching, kneeling and crouching were misclassified when compared to video observation. The activPAL3 appeared to accurately detect 'purposeful' stepping during ADL, but detection of smaller stepping movements was poor. Small variations in outcomes between monitors indicated that differences in monitor placement or hardware may affect outcomes. In general, the detection of posture and purposeful stepping with the activPAL3 was excellent indicating that it is a suitable monitor for characterising free-living posture and purposeful stepping activity in healthy adults and young people. Copyright © 2015 Elsevier B.V. All rights reserved.
Real time algorithms for sharp wave ripple detection.
Sethi, Ankit; Kemere, Caleb
2014-01-01
Neural activity during sharp wave ripples (SWR), short bursts of co-ordinated oscillatory activity in the CA1 region of the rodent hippocampus, is implicated in a variety of memory functions from consolidation to recall. Detection of these events in an algorithmic framework, has thus far relied on simple thresholding techniques with heuristically derived parameters. This study is an investigation into testing and improving the current methods for detection of SWR events in neural recordings. We propose and profile methods to reduce latency in ripple detection. Proposed algorithms are tested on simulated ripple data. The findings show that simple realtime algorithms can improve upon existing power thresholding methods and can detect ripple activity with latencies in the range of 10-20 ms.
Goense, J B M; Ratnam, R
2003-10-01
An important problem in sensory processing is deciding whether fluctuating neural activity encodes a stimulus or is due to variability in baseline activity. Neurons that subserve detection must examine incoming spike trains continuously, and quickly and reliably differentiate signals from baseline activity. Here we demonstrate that a neural integrator can perform continuous signal detection, with performance exceeding that of trial-based procedures, where spike counts in signal- and baseline windows are compared. The procedure was applied to data from electrosensory afferents of weakly electric fish (Apteronotus leptorhynchus), where weak perturbations generated by small prey add approximately 1 spike to a baseline of approximately 300 spikes s(-1). The hypothetical postsynaptic neuron, modeling an electrosensory lateral line lobe cell, could detect an added spike within 10-15 ms, achieving near ideal detection performance (80-95%) at false alarm rates of 1-2 Hz, while trial-based testing resulted in only 30-35% correct detections at that false alarm rate. The performance improvement was due to anti-correlations in the afferent spike train, which reduced both the amplitude and duration of fluctuations in postsynaptic membrane activity, and so decreased the number of false alarms. Anti-correlations can be exploited to improve detection performance only if there is memory of prior decisions.
Gateau, Jérôme; Aubry, Jean-François; Pernot, Mathieu; Fink, Mathias; Tanter, Mickaël
2011-03-01
The activation of natural gas nuclei to induce larger bubbles is possible using short ultrasonic excitations of high amplitude, and is required for ultrasound cavitation therapies. However, little is known about the distribution of nuclei in tissues. Therefore, the acoustic pressure level necessary to generate bubbles in a targeted zone and their exact location are currently difficult to predict. To monitor the initiation of cavitation activity, a novel all-ultrasound technique sensitive to single nucleation events is presented here. It is based on combined passive detection and ultrafast active imaging over a large volume using the same multi-element probe. Bubble nucleation was induced using a focused transducer (660 kHz, f-number = 1) driven by a high-power electric burst (up to 300 W) of one to two cycles. Detection was performed with a linear array (4 to 7 MHz) aligned with the single-element focal point. In vitro experiments in gelatin gel and muscular tissue are presented. The synchronized passive detection enabled radio-frequency data to be recorded, comprising high-frequency coherent wave fronts as signatures of the acoustic emissions linked to the activation of the nuclei. Active change detection images were obtained by subtracting echoes collected in the unnucleated medium. These indicated the appearance of stable cavitating regions. Because of the ultrafast frame rate, active detection occurred as quickly as 330 μs after the high-amplitude excitation and the dynamics of the induced regions were studied individually.
Gateau, Jérôme; Aubry, Jean-François; Pernot, Mathieu; Fink, Mathias; Tanter, Mickaël
2011-01-01
The activation of natural gas nuclei to induce larger bubbles is possible using short ultrasonic excitations of high amplitude, and is required for ultrasound cavitation therapies. However, little is known about the distribution of nuclei in tissues. Therefore, the acoustic pressure level necessary to generate bubbles in a targeted zone and their exact location are currently difficult to predict. In order to monitor the initiation of cavitation activity, a novel all-ultrasound technique sensitive to single nucleation events is presented here. It is based on combined passive detection and ultrafast active imaging over a large volume and with the same multi-element probe. Bubble nucleation was induced with a focused transducer (660kHz, f#=1) driven by a high power (up to 300 W) electric burst of one to two cycles. Detection was performed with a linear array (4–7MHz) aligned with the single-element focal point. In vitro experiments in gelatin gel and muscular tissue are presented. The synchronized passive detection enabled radio-frequency data to be recorded, comprising high-frequency coherent wave fronts as signatures of the acoustic emissions linked to the activation of the nuclei. Active change detection images were obtained by subtracting echoes collected in the unucleated medium. These indicated the appearance of stable cavitating regions. Thanks to the ultrafast frame rate, active detection occurred as soon as 330 μs after the high amplitude excitation and the dynamics of the induced regions were studied individually. PMID:21429844
Udukala, Dinusha N; Wang, Hongwang; Wendel, Sebastian O; Malalasekera, Aruni P; Samarakoon, Thilani N; Yapa, Asanka S; Abayaweera, Gayani; Basel, Matthew T; Maynez, Pamela; Ortega, Raquel; Toledo, Yubisela; Bossmann, Leonie; Robinson, Colette; Janik, Katharine E; Koper, Olga B; Li, Ping; Motamedi, Massoud; Higgins, Daniel A; Gadbury, Gary; Zhu, Gaohong; Troyer, Deryl L; Bossmann, Stefan H
2016-01-01
Proteases, including matrix metalloproteinases (MMPs), tissue serine proteases, and cathepsins (CTS) exhibit numerous functions in tumor biology. Solid tumors are characterized by changes in protease expression levels by tumor and surrounding tissue. Therefore, monitoring protease levels in tissue samples and liquid biopsies is a vital strategy for early cancer detection. Water-dispersable Fe/Fe3O4-core/shell based nanoplatforms for protease detection are capable of detecting protease activity down to sub-femtomolar limits of detection. They feature one dye (tetrakis(carboxyphenyl)porphyrin (TCPP)) that is tethered to the central nanoparticle by means of a protease-cleavable consensus sequence and a second dye (Cy 5.5) that is directly linked. Based on the protease activities of urokinase plasminogen activator (uPA), MMPs 1, 2, 3, 7, 9, and 13, as well as CTS B and L, human breast cancer can be detected at stage I by means of a simple serum test. By monitoring CTS B and L stage 0 detection may be achieved. This initial study, comprised of 46 breast cancer patients and 20 apparently healthy human subjects, demonstrates the feasibility of protease-activity-based liquid biopsies for early cancer diagnosis.
Samarakoon, Thilani N; Yapa, Asanka S; Abayaweera, Gayani; Basel, Matthew T; Maynez, Pamela; Ortega, Raquel; Toledo, Yubisela; Bossmann, Leonie; Robinson, Colette; Janik, Katharine E; Koper, Olga B; Li, Ping; Motamedi, Massoud; Higgins, Daniel A; Gadbury, Gary
2016-01-01
Summary Proteases, including matrix metalloproteinases (MMPs), tissue serine proteases, and cathepsins (CTS) exhibit numerous functions in tumor biology. Solid tumors are characterized by changes in protease expression levels by tumor and surrounding tissue. Therefore, monitoring protease levels in tissue samples and liquid biopsies is a vital strategy for early cancer detection. Water-dispersable Fe/Fe3O4-core/shell based nanoplatforms for protease detection are capable of detecting protease activity down to sub-femtomolar limits of detection. They feature one dye (tetrakis(carboxyphenyl)porphyrin (TCPP)) that is tethered to the central nanoparticle by means of a protease-cleavable consensus sequence and a second dye (Cy 5.5) that is directly linked. Based on the protease activities of urokinase plasminogen activator (uPA), MMPs 1, 2, 3, 7, 9, and 13, as well as CTS B and L, human breast cancer can be detected at stage I by means of a simple serum test. By monitoring CTS B and L stage 0 detection may be achieved. This initial study, comprised of 46 breast cancer patients and 20 apparently healthy human subjects, demonstrates the feasibility of protease-activity-based liquid biopsies for early cancer diagnosis. PMID:27335730
Amplified and in situ detection of redox-active metabolite using a biobased redox capacitor.
Kim, Eunkyoung; Gordonov, Tanya; Bentley, William E; Payne, Gregory F
2013-02-19
Redox cycling provides a mechanism to amplify electrochemical signals for analyte detection. Previous studies have shown that diverse mediators/shuttles can engage in redox-cycling reactions with a biobased redox capacitor that is fabricated by grafting redox-active catechols onto a chitosan film. Here, we report that redox cycling with this catechol-chitosan redox capacitor can amplify electrochemical signals for detecting a redox-active bacterial metabolite. Specifically, we studied the redox-active bacterial metabolite pyocyanin that is reported to be a virulence factor and signaling molecule for the opportunistic pathogen P. aeruginosa. We demonstrate that redox cycling can amplify outputs from various electrochemical methods (cyclic voltammetry, chronocoulometry, and differential pulse voltammetry) and can lower the detection limit of pyocyanin to 50 nM. Further, the compatibility of this biobased redox capacitor allows the in situ monitoring of the production of redox-active metabolites (e.g., pyocyanin) during the course of P. aeruginosa cultivation. We anticipate that the amplified output of redox-active virulence factors should permit an earlier detection of life-threatening infections by the opportunistic pathogen P. aeruginosa while the "bio-compatibility" of this measurement approach should facilitate in situ study of the spatiotemporal dynamics of bacterial redox signaling.
Electro-optical system for gunshot detection: analysis, concept, and performance
NASA Astrophysics Data System (ADS)
Kastek, M.; Dulski, R.; Madura, H.; Trzaskawka, P.; Bieszczad, G.; Sosnowski, T.
2011-08-01
The paper discusses technical possibilities to build an effective electro-optical sensor unit for sniper detection using infrared cameras. This unit, comprising of thermal and daylight cameras, can operate as a standalone device but its primary application is a multi-sensor sniper and shot detection system. At first, the analysis was presented of three distinguished phases of sniper activity: before, during and after the shot. On the basis of experimental data the parameters defining the relevant sniper signatures were determined which are essential in assessing the capability of infrared camera to detect sniper activity. A sniper body and muzzle flash were analyzed as targets and the descriptions of phenomena which make it possible to detect sniper activities in infrared spectra as well as analysis of physical limitations were performed. The analyzed infrared systems were simulated using NVTherm software. The calculations for several cameras, equipped with different lenses and detector types were performed. The simulation of detection ranges was performed for the selected scenarios of sniper detection tasks. After the analysis of simulation results, the technical specifications of infrared sniper detection system were discussed, required to provide assumed detection range. Finally the infrared camera setup was proposed which can detected sniper from 1000 meters range.
Wang, Aicheng; Zhao, Huimin; Chen, Xiaochi; Tan, Bing; Zhang, Yaobin; Quan, Xie
2017-05-15
A sensitive, rapid and label-free colorimetric aptasensor for sulfadimethoxine (SDM) detection was developed based on the tunable peroxidase-like activity of graphene/nickel@palladium nanoparticle (Gr/Ni@Pd) hybrids. The addition of the SDM aptamer could inhibit the peroxidase-like catalytic activity of the hybrids. However, the target SDM and aptamer could be triggered tightly and recover the catalytic activity of the Gr/Ni@Pd hybrids. Due to the peroxidase-like catalytic activity, Gr/Ni@Pd could catalyze the decomposition of H 2 O 2 with releasing hydroxyl radicals which further oxidized reagent 3, 3', 5, 5'-Tetramethylbenzidine (TMB) to oxTMB accompanied with a colorless-to-blue color change. The original color change could be applied to obtain quantitative detection of SDM, due to the relationship between the concentration of the target and the color difference. As a result, this approach performed a linear response for SDM from 1 to 500 ng/mL with a limit detection of 0.7 ng/mL (S/N = 3) under the optimized conditions and realized the detection of SDM in spiked lake water samples. Therefore, this colorimetric aptasensor was an alternative assay for SDM detection in real water. Moreover, with its design principle, this work might be applied to detecting other small molecule by employing appropriate aptamer. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhang, Linqun; Liu, Yuanjian; Li, Ying; Zhao, Yuewu; Wei, Wei; Liu, Songqin
2016-08-24
A mimic-hybridization chain reaction (mimic-HCR) amplified strategy was proposed for sensitive electrochemically detection of DNA methylation and methyltransferase (MTase) activity In the presence of methylated DNA, DNA-gold nanoparticles (DNA-AuNPs) were captured on the electrode by sandwich-type assembly. It then triggered mimic-HCR of two hairpin probes to produce many long double-helix chains for numerous hexaammineruthenium (III) chloride ([Ru(NH3)6](3+), RuHex) inserting. As a result, the signal for electrochemically detection of DNA MTase activity could be amplified. If DNA was non-methylated, however, the sandwich-type assembly would not form because the short double-stranded DNAs (dsDNA) on the Au electrode could be cleaved and digested by restriction endonuclease HpaII (HapII) and exonuclease III (Exo III), resulting in the signal decrement. Based on this, an electrochemical approach for detection of M.SssI MTase activity with high sensitivity was developed. The linear range for M.SssI MTase activity was from 0.05 U mL(-1) to 10 U mL(-1), with a detection limit down to 0.03 U mL(-1). Moreover, this detecting strategy held great promise as an easy-to-use and highly sensitive method for other MTase activity and inhibition detection by exchanging the corresponding DNA sequence. Copyright © 2016 Elsevier B.V. All rights reserved.
Intraspecific Variation of Centruroides Edwardsii Venom from Two Regions of Colombia
Estrada-Gómez, Sebastián; Cupitra, Nelson Ivan; Arango, Walter Murillo; Vargas Muñoz, Leidy Johana
2014-01-01
We report the first description studies, partial characterization, and intraspecific difference of Centruroides edwardsii, Gervais 1843, venom. C. edwardsii from two Colombian regions (Antioquia and Tolima) were evaluated. Both venoms showed hemolytic activity, possibly dependent of enzymatic active phospholipases, and neither coagulant nor proteolytic activities were observed. Venom electrophoretic profile showed significant differences between C. edwardsii venom from both regions. A high concentration of proteins with molecular masses between 31 kDa and 97.4 kDa, and an important concentration close or below 14.4 kDa were detected. RP-HPLC retention times between 38.2 min and 42.1 min, showed bands close to 14.4 kDa, which may correspond to phospholipases. RP-HPLC venom profile showed a well conserved region in both venoms between 7 and 17 min, after this, significant differences were detected. From Tolima region venom, 50 well-defined peaks were detected, while in the Antioquia region venom, 55 well-defined peaks were detected. Larvicidal activity was only detected in the C. edwardsii venom from Antioquia. No antimicrobial activity was observed using complete venom or RP-HPLC collected fractions of both venoms. Lethally activity (carried out on female albino swiss mice) was detected at doses over 19.2 mg/kg of crude venom. Toxic effects included distress, excitability, eye irritation and secretions, hyperventilation, ataxia, paralysis, and salivation. PMID:25025710
Trong Bui, Duong; Nguyen, Nhan Duc; Jeong, Gu-Min
2018-06-25
Human activity recognition and pedestrian dead reckoning are an interesting field because of their importance utilities in daily life healthcare. Currently, these fields are facing many challenges, one of which is the lack of a robust algorithm with high performance. This paper proposes a new method to implement a robust step detection and adaptive distance estimation algorithm based on the classification of five daily wrist activities during walking at various speeds using a smart band. The key idea is that the non-parametric adaptive distance estimator is performed after two activity classifiers and a robust step detector. In this study, two classifiers perform two phases of recognizing five wrist activities during walking. Then, a robust step detection algorithm, which is integrated with an adaptive threshold, peak and valley correction algorithm, is applied to the classified activities to detect the walking steps. In addition, the misclassification activities are fed back to the previous layer. Finally, three adaptive distance estimators, which are based on a non-parametric model of the average walking speed, calculate the length of each strike. The experimental results show that the average classification accuracy is about 99%, and the accuracy of the step detection is 98.7%. The error of the estimated distance is 2.2⁻4.2% depending on the type of wrist activities.
Mohamad, Saharuddin Bin; Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Nakagawa, Yoshinori; Kawashima, Ken; Hori, Hitoshi
2003-01-01
Gc protein is the precursor for Gc protein-derived macrophage activating factor (GcMAF), with three phenotypes: Gc1f, Gc1s and Gc2, based on its electrophoretic mobility. The difference in electrophoretic mobility is because of the difference in its posttranslational sugar moiety composition. We compared the difference between Gc protein and GcMAF electrophoretic mobility using the isoelectric focusing (IEF) method. The tumoricidal activity of GcMAF-treated macrophage was evaluated after coculture with L-929 cell. The tumoricidal mechanism was investigated using TNF bioassay and nitric oxide (NO) release. The difference in Gc protein and GcMAF electrophoretic mobility was detected. The tumoricidal activity of GcMAF-treated macrophage was detected, but no release of TNF and NO was detected. The difference of isoelectric focusing mobility in Gc protein and GcMAF would be useful to develop a GcMAF detection method. GcMAF increased macrophage tumoricidal activity but TNF and NO release were not involved in the mechanism.
Using Scientific Detective Videos to Support the Design of Technology Learning Activities
ERIC Educational Resources Information Center
Yu, Kuang-Chao; Fan, Szu-Chun; Tsai, Fu-Hsing; Chu, Yih-hsien
2013-01-01
This article examines the effect of scientific detective video as a vehicle to support the design of technology activities by technology teachers. Ten graduate students, including current and future technology teachers, participated in a required technology graduate course that used scientific detective videos as a pedagogical tool to motivate…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roucayrol, J.; Taillandier, P.
1963-05-27
In order to detect the BETA activities on a thin-film chromatogram, it is expedient to impregnate it with a gelatinized scintillator. The fluorescence photons are detected by a photomultiplier across a slit'' above which the glass support of the chromatogram is removed. (tr-auth)
12 CFR 391.23 - Duties of card issuers regarding changes of address.
Code of Federal Regulations, 2012 CFR
2012-01-01
... detect relevant Red Flags that may arise in the performance of the service provider's activities, and... or creditor detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of..., App. Appendix to Subpart C of Part 391—Interagency Guidelines on Identity Theft Detection, Prevention...
Code of Federal Regulations, 2011 CFR
2011-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...
Code of Federal Regulations, 2012 CFR
2012-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...
Code of Federal Regulations, 2013 CFR
2013-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...
Code of Federal Regulations, 2014 CFR
2014-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...
A Facile Stable-Isotope Dilution Method for Determination of Sphingosine Phosphate Lyase Activity
Suh, Jung H.; Eltanawy, Abeer; Rangan, Apoorva; Saba, Julie D.
2015-01-01
A new technique for quantifying sphingosine phosphate lyase activity in biological samples is described. In this procedure, 2-hydrazinoquinoline is used to convert (2E)-hexadecenal into the corresponding hydrazone derivative to improve ionization efficiency and selectivity of detection. Combined utilization of liquid chromatographic separation and multiple reaction monitoring-mass spectrometry allows for simultaneous quantification of the substrate S1P and product (2E)-hexadecenal. Incorporation of (2E)-d5-hexadecenal as an internal standard improves detection accuracy and precision. A simple one-step derivatization procedure eliminates the need for further extractions. Limits of quantification for (2E)-hexadecenal and sphingosine-1-phosphate are 100 and 50 fmol, respectively. The assay displays a wide dynamic detection range useful for detection of low basal sphingosine phosphate lyase activity in wild type cells, SPL-overexpressing cell lines, and wild type mouse tissues. Compared to current methods, the capacity for simultaneous detection of sphingosine-1-phosphate and (2E)-hexadecenal greatly improves the accuracy of results and shows excellent sensitivity and specificity for sphingosine phosphate lyase activity detection. PMID:26408264
Rutten, C J; Steeneveld, W; Inchaisri, C; Hogeveen, H
2014-11-01
The technical performance of activity meters for automated detection of estrus in dairy farming has been studied, and such meters are already used in practice. However, information on the economic consequences of using activity meters is lacking. The current study analyzes the economic benefits of a sensor system for detection of estrus and appraises the feasibility of an investment in such a system. A stochastic dynamic simulation model was used to simulate reproductive performance of a dairy herd. The number of cow places in this herd was fixed at 130. The model started with 130 randomly drawn cows (in a Monte Carlo process) and simulated calvings and replacement of these cows in subsequent years. Default herd characteristics were a conception rate of 50%, an 8-wk dry-off period, and an average milk production level of 8,310 kg per cow per 305 d. Model inputs were derived from real farm data and expertise. For the analysis, visual detection by the farmer ("without" situation) was compared with automated detection with activity meters ("with" situation). For visual estrus detection, an estrus detection rate of 50% and a specificity of 100% were assumed. For automated estrus detection, an estrus detection rate of 80% and a specificity of 95% were assumed. The results of the cow simulation model were used to estimate the difference between the annual net cash flows in the "with" and "without" situations (marginal financial effect) and the internal rate of return (IRR) as profitability indicators. The use of activity meters led to improved estrus detection and, therefore, to a decrease in the average calving interval and subsequent increase in annual milk production. For visual estrus detection, the average calving interval was 419 d and average annual milk production was 1,032,278 kg. For activity meters, the average calving interval was 403 d and the average annual milk production was 1,043,398 kg. It was estimated that the initial investment in activity meters would cost €17,728 for a herd of 130 cows, with an additional cost of €90 per year for the replacement of malfunctioning activity meters. Changes in annual net cash flows arising from using an activity meter included extra revenues from increased milk production and number of calves sold, increased costs from more inseminations, calvings, and feed consumption, and reduced costs from fewer culled cows and less labor for estrus detection. These changes in cash flows were caused mainly by changes in the technical results of the simulated dairy herds, which arose from differences in the estrus detection rate and specificity between the "with" and "without" situations. The average marginal financial effect in the "with" and "without" situations was €2,827 for the baseline scenario, with an average IRR of 11%. The IRR is a measure of the return on invested capital. Investment in activity meters was generally profitable. The most influential assumptions on the profitability of this investment were the assumed culling rules and the increase in sensitivity of estrus detection between the "without" and the "with" situation. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
McCutchen-Maloney, Sandra L.
2002-01-01
Chimeric proteins having both DNA mutation binding activity and nuclease activity are synthesized by recombinant technology. The proteins are of the general formula A-L-B and B-L-A where A is a peptide having DNA mutation binding activity, L is a linker and B is a peptide having nuclease activity. The chimeric proteins are useful for detection and identification of DNA sequence variations including DNA mutations (including DNA damage and mismatches) by binding to the DNA mutation and cutting the DNA once the DNA mutation is detected.
NASA Astrophysics Data System (ADS)
Tejedor, J.; Macias-Guarasa, J.; Martins, H. F.; Piote, D.; Pastor-Graells, J.; Martin-Lopez, S.; Corredera, P.; De Pauw, G.; De Smet, F.; Postvoll, W.; Ahlen, C. H.; Gonzalez-Herraez, M.
2017-04-01
This paper presents the first report on on-line and final blind field test results of a pipeline integrity threat surveillance system. The system integrates a machine+activity identification mode, and a threat detection mode. Two different pipeline sections were selected for the blind tests: One close to the sensor position, and the other 35 km away from it. Results of the machine+activity identification mode showed that about 46% of the times the machine, the activity or both were correctly identified. For the threat detection mode, 8 out of 10 threats were correctly detected, with 1 false alarm.
Galileo Near-Infrared Mapping Spectrometer Detects Active Lava Flows at Prometheus Volcano, Io
1999-11-04
The active volcano Prometheus on Jupiter moon Io was imaged by NASA Galileo spacecraft during the close flyby of Io on Oct.10, 1999. The spectrometer can detect active volcanoes on Io by measuring their heat in the near-infrared wavelengths.
Ling, Pinghua; Lei, Jianping; Jia, Li; Ju, Huangxian
2016-01-21
A simple and rapid electrochemical sensor is constructed for the detection of telomerase activity based on the electrocatalysis of platinum nanoparticle (Pt NP) encapsulated metal-organic frameworks (MOFs), which are synthesized by one-pot encapsulation of Pt NPs into prototypal MOFs, UiO-66-NH2. Integrating with the efficient electrocatalysis of Pt@MOFs towards NaBH4 oxidation, this biosensor shows the wide dynamic correlation of telomerase activity from 5 × 10(2) to 10(7) HeLa cells mL(-1) and the telomerase activity in a single HeLa cell was calculated to be 2.0 × 10(-11) IU, providing a powerful platform for detecting telomerase activity.
Lee, Young-Sook; Chung, Wan-Young
2012-01-01
Vision-based abnormal event detection for home healthcare systems can be greatly improved using visual sensor-based techniques able to detect, track and recognize objects in the scene. However, in moving object detection and tracking processes, moving cast shadows can be misclassified as part of objects or moving objects. Shadow removal is an essential step for developing video surveillance systems. The goal of the primary is to design novel computer vision techniques that can extract objects more accurately and discriminate between abnormal and normal activities. To improve the accuracy of object detection and tracking, our proposed shadow removal algorithm is employed. Abnormal event detection based on visual sensor by using shape features variation and 3-D trajectory is presented to overcome the low fall detection rate. The experimental results showed that the success rate of detecting abnormal events was 97% with a false positive rate of 2%. Our proposed algorithm can allow distinguishing diverse fall activities such as forward falls, backward falls, and falling asides from normal activities. PMID:22368486
Attentional Capacity Limits Gap Detection during Concurrent Sound Segregation.
Leung, Ada W S; Jolicoeur, Pierre; Alain, Claude
2015-11-01
Detecting a brief silent interval (i.e., a gap) is more difficult when listeners perceive two concurrent sounds rather than one in a sound containing a mistuned harmonic in otherwise in-tune harmonics. This impairment in gap detection may reflect the interaction of low-level encoding or the division of attention between two sound objects, both of which could interfere with signal detection. To distinguish between these two alternatives, we compared ERPs during active and passive listening with complex harmonic tones that could include a gap, a mistuned harmonic, both features, or neither. During active listening, participants indicated whether they heard a gap irrespective of mistuning. During passive listening, participants watched a subtitled muted movie of their choice while the same sounds were presented. Gap detection was impaired when the complex sounds included a mistuned harmonic that popped out as a separate object. The ERP analysis revealed an early gap-related activity that was little affected by mistuning during the active or passive listening condition. However, during active listening, there was a marked decrease in the late positive wave that was thought to index attention and response-related processes. These results suggest that the limitation in detecting the gap is related to attentional processing, possibly divided attention induced by the concurrent sound objects, rather than deficits in preattentional sensory encoding.
NASA Astrophysics Data System (ADS)
Mehta, Kalpesh; Hasnain, Ali; Zhou, Xiaowei; Luo, Jianwen; Penney, Trevor B.; Chen, Nanguang
2017-04-01
Diffuse optical spectroscopy (DOS) and imaging methods have been widely applied to noninvasive detection of brain activity. We have designed and implemented a low cost, portable, real-time one-channel time-resolved DOS system for neuroscience studies. Phantom experiments were carried out to test the performance of the system. We further conducted preliminary human experiments and demonstrated that enhanced sensitivity in detecting neural activity in the cortex could be achieved by the use of late arriving photons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDeavitt, Sean M.
The content of this report summarizes a multi-year effort to develop prototype detection equipment using the Tensioned Metastable Fluid Detector (TMFD) technology developed by Taleyarkhan [1]. The context of this development effort was to create new methods for evaluating and developing advanced methods for safeguarding nuclear materials along with instrumentation in various stages of the fuel cycle, especially in material balance areas (MBAs) and during reprocessing of used nuclear fuel. One of the challenges related to the implementation of any type of MBA and/or reprocessing technology (e.g., PUREX or UREX) is the real-time quantification and control of the transuranic (TRU)more » isotopes as they move through the process. Monitoring of higher actinides from their neutron emission (including multiplicity) and alpha signatures during transit in MBAs and in aqueous separations is a critical research area. By providing on-line real-time materials accountability, diversion of the materials becomes much more difficult. The Tensioned Metastable Fluid Detector (TMFD) is a transformational technology that is uniquely capable of both alpha and neutron spectroscopy while being “blind” to the intense gamma field that typically accompanies used fuel – simultaneously with the ability to provide multiplicity information as well [1-3]. The TMFD technology was proven (lab-scale) as part of a 2008 NERI-C program [1-7]. The bulk of this report describes the advancements and demonstrations made in TMFD technology. One final point to present before turning to the TMFD demonstrations is the context for discussing real-time monitoring of SNM. It is useful to review the spectrum of isotopes generated within nuclear fuel during reactor operations. Used nuclear fuel (UNF) from a light water reactor (LWR) contains fission products as well as TRU elements formed through neutron absorption/decay chains. The majority of the fission products are gamma and beta emitters and they represent the more significant hazards from a radiation protection standpoint. However, alpha and neutron emitting uranium and TRU elements represent the more significant safeguards and security concerns. Table 1.1 presents a representative PWR inventory of the uranium and actinide isotopes present in a used fuel assembly. The uranium and actinide isotopes (chiefly the Pu, Am and Cm elements) are all emitters of alpha particles and some of them release significant quantities of neutrons through spontaneous fissions« less
A new effective assay to detect antimicrobial activity of filamentous fungi.
Pereira, Eric; Santos, Ana; Reis, Francisca; Tavares, Rui M; Baptista, Paula; Lino-Neto, Teresa; Almeida-Aguiar, Cristina
2013-01-15
The search for new antimicrobial compounds and the optimization of production methods turn the use of antimicrobial susceptibility tests a routine. The most frequently used methods are based on agar diffusion assays or on dilution in agar or broth. For filamentous fungi, the most common antimicrobial activity detection methods comprise the co-culture of two filamentous fungal strains or the use of fungal extracts to test against single-cell microorganisms. Here we report a rapid, effective and reproducible assay to detect fungal antimicrobial activity against single-cell microorganisms. This method allows an easy way of performing a fast antimicrobial screening of actively growing fungi directly against yeast. Because it makes use of an actively growing mycelium, this bioassay also provides a way for studying the production dynamics of antimicrobial compounds by filamentous fungi. The proposed assay is less time consuming and introduces the innovation of allowing the direct detection of fungal antimicrobial properties against single cell microorganisms without the prior isolation of the active substance(s). This is particularly useful when performing large screenings for fungal antimicrobial activity. With this bioassay, antimicrobial activity of Hypholoma fasciculare against yeast species was observed for the first time. Copyright © 2012 Elsevier GmbH. All rights reserved.
Conley, Justin M; Evans, Nicola; Cardon, Mary C; Rosenblum, Laura; Iwanowicz, Luke R; Hartig, Phillip C; Schenck, Kathleen M; Bradley, Paul M; Wilson, Vickie S
2017-05-02
In vitro bioassays are sensitive, effect-based tools used to quantitatively screen for chemicals with nuclear receptor activity in environmental samples. We measured in vitro estrogen (ER), androgen (AR), and glucocorticoid receptor (GR) activity, along with a broad suite of chemical analytes, in streamwater from 35 well-characterized sites (3 reference and 32 impacted) across 24 states and Puerto Rico. ER agonism was the most frequently detected with nearly all sites (34/35) displaying activity (range, 0.054-116 ng E2Eq L -1 ). There was a strong linear relationship (r 2 = 0.917) between in vitro ER activity and concentrations of steroidal estrogens after correcting for the in vitro potency of each compound. AR agonism was detected in 5/35 samples (range, 1.6-4.8 ng DHTEq L -1 ) but concentrations of androgenic compounds were largely unable to account for the in vitro activity. Similarly, GR agonism was detected in 9/35 samples (range, 6.0-43 ng DexEq L -1 ); however, none of the recognized GR-active compounds on the target-chemical analyte list were detected. The utility of in vitro assays in water quality monitoring was evident from both the quantitative agreement between ER activity and estrogen concentrations, as well as the detection of AR and GR activity for which there were limited or no corresponding target-chemical detections to explain the bioactivity. Incorporation of in vitro bioassays as complements to chemical analyses in standard water quality monitoring efforts would allow for more complete assessment of the chemical mixtures present in many surface waters.
Maselli, M; Giantin, V; Franchin, A; Zanatta, F; Sarti, S; Corradin, M L; Tramontano, A; Stifani, B; Sergi, G; Manzato, E
2014-08-01
Physiological aging can lead to an increase in blood pressure (BP) over time even in regularly exercising elders. Office BP measurements (OBPM) might be unable to detect these BP variations. The aim of this study was to analyze BP changes over 3.5 years in active elders using ABPM. The study involved 80 active subjects ≥65 years old who exercised regularly. At baseline and again 3.5 years later, all subjects had lab tests, weight, body mass index (BMI), body composition, resting energy expenditure (REE) recorded; they underwent OBPM, ABPM and physical activity assessment. Over 3.5 years, our sample's mean weight, BMI, body composition, REE, albumin, and physical activity levels, did not change significantly. The prevalence of hypertension detected by OBPM dropped from 68.8% to 61.3%. ABPM revealed an increase in mean 24-h BP (Δsystolic: 5.3 ± 13.6 mmHg; p = 0.001; Δdiastolic: 1.8 ± 6.7 mmHg; p = 0.018) and mean daytime BP (Δsystolic: 5.8 ± 13.5 mmHg; p = 0.001; Δdiastolic: 1.9 ± 7.1 mmHg; p = 0.022); the prevalence of hypertension detected by ABPM increased from 50% to 65%, also due to an increase (from 8.8% to 16.3%) in masked hypertension. There was no correlation between BP changes and changes in body composition and REE. BP tends to increase over time in active elders, regardless of changes in body composition or level of physical activity. ABPM is an appropriate method for detecting these BP variations in active elders and to reveal cases of masked hypertension that might otherwise escape detection by OBPM. Copyright © 2014 Elsevier B.V. All rights reserved.
Conley, Justin M.; Evans, Nicola; Cardon, Mary C.; Rosenblum, Laura; Iwanowicz, Luke R.; Hartig, Phillip C.; Schenck, Kathleen M.; Bradley, Paul M.; Wilson, Vickie S.
2017-01-01
In vitro bioassays are sensitive, effect-based tools used to quantitatively screen for chemicals with nuclear receptor activity in environmental samples. We measured in vitro estrogen (ER), androgen (AR), and glucocorticoid receptor (GR) activity, along with a broad suite of chemical analytes, in streamwater from 35 well-characterized sites (3 reference and 32 impacted) across 24 states and Puerto Rico. ER agonism was the most frequently detected with nearly all sites (34/35) displaying activity (range, 0.054–116 ng E2Eq L–1). There was a strong linear relationship (r2 = 0.917) between in vitro ER activity and concentrations of steroidal estrogens after correcting for the in vitro potency of each compound. AR agonism was detected in 5/35 samples (range, 1.6–4.8 ng DHTEq L–1) but concentrations of androgenic compounds were largely unable to account for the in vitro activity. Similarly, GR agonism was detected in 9/35 samples (range, 6.0–43 ng DexEq L–1); however, none of the recognized GR-active compounds on the target-chemical analyte list were detected. The utility of in vitro assays in water quality monitoring was evident from both the quantitative agreement between ER activity and estrogen concentrations, as well as the detection of AR and GR activity for which there were limited or no corresponding target-chemical detections to explain the bioactivity. Incorporation of in vitro bioassays as complements to chemical analyses in standard water quality monitoring efforts would allow for more complete assessment of the chemical mixtures present in many surface waters.
Spotting stellar activity cycles in Gaia astrometry
NASA Astrophysics Data System (ADS)
Morris, Brett M.; Agol, Eric; Davenport, James R. A.; Hawley, Suzanne L.
2018-06-01
Astrometry from Gaia will measure the positions of stellar photometric centroids to unprecedented precision. We show that the precision of Gaia astrometry is sufficient to detect starspot-induced centroid jitter for nearby stars in the Tycho-Gaia Astrometric Solution (TGAS) sample with magnetic activity similar to the young G-star KIC 7174505 or the active M4 dwarf GJ 1243, but is insufficient to measure centroid jitter for stars with Sun-like spot distributions. We simulate Gaia observations of stars with 10 year activity cycles to search for evidence of activity cycles, and find that Gaia astrometry alone likely cannot detect activity cycles for stars in the TGAS sample, even if they have spot distributions like KIC 7174505. We review the activity of the nearby low-mass stars in the TGAS sample for which we anticipate significant detections of spot-induced jitter.
Piezoelectric and Electrostatic Polymeric Transducers for Acoustic Emission Detection.
1984-12-01
the fabrication of ultrasonic transducers for acoustic emission (A.E.) detection using polyvinylidene fluoride ( PVDF ) active elements. ii) the...characterization of PVDF transducers. The second report compared the sensitivity of PVDF transducers with polypropylene electrostatic transducer...detection using polyvinylidene 1uoride ( PVDF ) active elements. ii) the fabrication of electrostatic transducers using thin film of non-polar
Detection of botulinum toxin types A, B, E, and F activity using the quail embryo
USDA-ARS?s Scientific Manuscript database
We recently demonstrated an effective new model for the detection of botulinum toxin type A using quail embryos in place of the mouse model. These experiments demonstrated that the Japanese quail embryo at 15 days of incubation was an effective vertebrate animal model to detect the activity of botu...
Code of Federal Regulations, 2012 CFR
2012-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 41 Banks and Banking COMPTROLLER OF THE CURRENCY...
Code of Federal Regulations, 2013 CFR
2013-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...
Code of Federal Regulations, 2013 CFR
2013-01-01
... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...
Code of Federal Regulations, 2013 CFR
2013-01-01
... the financial institution or creditor should take steps to ensure that the activity of the service... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation Appendix to Subpart C of Part 391 Banks and Banking FEDERAL DEPOSIT...
Code of Federal Regulations, 2011 CFR
2011-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 41 Banks and Banking COMPTROLLER OF THE CURRENCY...
Code of Federal Regulations, 2014 CFR
2014-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...
Code of Federal Regulations, 2014 CFR
2014-04-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Identity Theft Detection, Prevention, and Mitigation A Appendix A to Subpart C of Part 248 Commodity and...
Code of Federal Regulations, 2013 CFR
2013-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 41 Banks and Banking COMPTROLLER OF THE CURRENCY...
Code of Federal Regulations, 2014 CFR
2014-01-01
... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...
Code of Federal Regulations, 2014 CFR
2014-01-01
... the financial institution or creditor should take steps to ensure that the activity of the service... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation Appendix to Subpart C of Part 391 Banks and Banking FEDERAL DEPOSIT...
Code of Federal Regulations, 2011 CFR
2011-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...
Code of Federal Regulations, 2012 CFR
2012-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...
Code of Federal Regulations, 2014 CFR
2014-01-01
... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 41 Banks and Banking COMPTROLLER OF THE CURRENCY...
Code of Federal Regulations, 2012 CFR
2012-01-01
... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...
Surface Plasmon Resonance Label-Free Monitoring of Antibody Antigen Interactions in Real Time
ERIC Educational Resources Information Center
Kausaite, Asta; van Dijk, Martijn; Castrop, Jan; Ramanaviciene, Almira; Baltrus, John P.; Acaite, Juzefa; Ramanavicius, Arunas
2007-01-01
Detection of biologically active compounds is one of the most important topics in molecular biology and biochemistry. One of the most promising detection methods is based on the application of surface plasmon resonance for label-free detection of biologically active compounds. This method allows one to monitor binding events in real time without…
A Smart DNA Tweezer for Detection of Human Telomerase Activity.
Xu, Xiaowen; Wang, Lei; Li, Kan; Huang, Qihong; Jiang, Wei
2018-03-06
Reliable and accurate detection of telomerase activity is crucial to better understand its role in cancer cells and to further explore its function in cancer diagnosis and treatment. Here, we construct a smart DNA tweezer (DT) for detection of telomerase activity. The DT is assembled by three specially designed single-stranded oligonucleotides: a central strand dually labeled with donor/acceptor fluorophores and two arm strands containing overhangs complementary to telomerase reaction products (TRPs). It can get closed through hybridization with TRPs and get reopen through strand displacement reaction by TRPs' complementary sequences. First, under the action of telomerase, telomerase binding substrates (TS) are elongated to generate TRPs ended with telomeric repeats (TTAGGG) n . TRPs hybridize with the two arm overhangs cooperatively and strain DT to closed state, inducing an increased fluorescence resonance energy transfer (FRET) efficiency, which is utilized for telomerase activity detection. Second, upon introduction of a removal strand (RS) complementary to TRPs, the closed DT is relaxed to open state via the toehold-mediated strand displacement, inducing a decreased FRET efficiency, which is utilized for determination of TRP length distribution. The detection limit of telomerase activity is equivalent to 141 cells/μL for HeLa cells, and telomerase-active cellular extracts can be differentiated from telomerase-inactive cellular extracts. Furthermore, TRPs owning 1, 2, 3, 4, and ≥5 telomeric repeats are identified to account for 25.6%, 20.5%, 15.7%, 12.5%, and 25.7%, respectively. The proposed strategy will offer a new approach for reliable, accurate detection of telomerase activity and product length distribution for deeper studying its role and function in cancer.
Preparation and evaluation of carriers for detection of cholinesterase inhibitors.
Vetchý, David; Pitschmann, Vladimír; Vetchá, Martina; Kašparovský, Tomáš; Matějovský, Lukáš
2015-01-01
The aim of the study was to use methods of pharmaceutical technology, and prepare carriers in the form of pellets suitable as a filling of detection tubes for enzymatic detection of cholinesterase inhibitors. The enzymatic detection was based on enzymatic hydrolysis of acetylthiocholine iodide and the subsequent colour reaction of its hydrolysis product with Ellman's reagent. The suitable carriers should be in the form of white, regular and sufficiently mechanically resistant particles of about 1 mm allowing it to capture the enzyme during the impregnation process and ensuring its high activity for enzymatic detection. Carriers consisting of microcrystalline cellulose, lactose, povidone, and sodium carboxymethyl cellulose were prepared using extrusion-spheronization method under three different drying conditions in either a hot air oven or a microwave oven. Subsequently, the carriers were impregnated with acetylcholinesterase and their size, shape, mechanical resistance, bulk, tapped and pycnometric density, Hausner ratio, intraparticular and total tapped porosity, and activity were measured and recorded. In this procedure, carriers with different physical parameters and different acetylcholinesterase activity were evaluated. It was found that higher acetylcholinesterase activity was associated not only with a higher intraparticular porosity but also with more regular particles characterized by high sphericity and low total tapped porosity. This unique finding is important for the preparation of detection tubes based on enzymatic detection which is still irreplaceable especially in the field of detection and analysis of super-toxic cholinesterase inhibitors.
Hoefel, Daniel; Monis, Paul T.; Grooby, Warwick L.; Andrews, Stuart; Saint, Christopher P.
2005-01-01
Chloramination is often the disinfection regimen of choice for extended drinking water systems. However, this process is prone to instability due to the growth of nitrifying bacteria. This is the first study to use alternative approaches for rapid investigation of chloraminated drinking water system instability in which flow cytometric cell sorting of bacteria with intact membranes (membrane-intact fraction) (BacLight kit) or with active esterases (esterase-active fraction) (carboxyfluorescein diacetate) was combined with 16S rRNA gene-directed PCR and denaturing gradient gel electrophoresis (DGGE). No active bacteria were detected when water left the water treatment plant (WTP), but 12 km downstream the chloramine residual had diminished and the level of active bacteria in the bulk water had increased to more than 1 × 105 bacteria ml−1. The bacterial diversity in the system was represented by six major DGGE bands for the membrane-intact fraction and 10 major DGGE bands for the esterase-active fraction. PCR targeting of the 16S rRNA gene of chemolithotrophic ammonia-oxidizing bacteria (AOB) and subsequent DGGE and DNA sequence analysis revealed the presence of an active Nitrosospira-related species and Nitrosomonas cryotolerans in the system, but no AOB were detected in the associated WTP. The abundance of active AOB was then determined by quantitative real-time PCR (qPCR) targeting the amoA gene; 3.43 × 103 active AOB ml−1 were detected in the membrane-intact fraction, and 1.40 × 104 active AOB ml−1 were detected in the esterase-active fraction. These values were several orders of magnitude greater than the 2.5 AOB ml−1 detected using a routine liquid most-probable-number assay. Culture-independent techniques described here, in combination with existing chemical indicators, should allow the water industry to obtain more comprehensive data with which to make informed decisions regarding remedial action that may be required either prior to or during an instability event. PMID:16269672
Azim, Riyasat; Li, Fangxing; Xue, Yaosuo; ...
2017-07-14
Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azim, Riyasat; Li, Fangxing; Xue, Yaosuo
Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only whenmore » the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.« less
Active shape models incorporating isolated landmarks for medical image annotation
NASA Astrophysics Data System (ADS)
Norajitra, Tobias; Meinzer, Hans-Peter; Stieltjes, Bram; Maier-Hein, Klaus H.
2014-03-01
Apart from their robustness in anatomic surface segmentation, purely surface based 3D Active Shape Models lack the ability to automatically detect and annotate non-surface key points of interest. However, annotation of anatomic landmarks is desirable, as it yields additional anatomic and functional information. Moreover, landmark detection might help to further improve accuracy during ASM segmentation. We present an extension of surface-based 3D Active Shape Models incorporating isolated non-surface landmarks. Positions of isolated and surface landmarks are modeled conjoint within a point distribution model (PDM). Isolated landmark appearance is described by a set of haar-like features, supporting local landmark detection on the PDM estimates using a kNN-Classi er. Landmark detection was evaluated in a leave-one-out cross validation on a reference dataset comprising 45 CT volumes of the human liver after shape space projection. Depending on the anatomical landmark to be detected, our experiments have shown in about 1/4 up to more than 1/2 of all test cases a signi cant improvement in detection accuracy compared to the position estimates delivered by the PDM. Our results encourage further research with regard to the combination of shape priors and machine learning for landmark detection within the Active Shape Model Framework.
Differential Sources for 2 Neural Signatures of Target Detection: An Electrocorticography Study.
Kam, J W Y; Szczepanski, S M; Canolty, R T; Flinker, A; Auguste, K I; Crone, N E; Kirsch, H E; Kuperman, R A; Lin, J J; Parvizi, J; Knight, R T
2018-01-01
Electrophysiology and neuroimaging provide conflicting evidence for the neural contributions to target detection. Scalp electroencephalography (EEG) studies localize the P3b event-related potential component mainly to parietal cortex, whereas neuroimaging studies report activations in both frontal and parietal cortices. We addressed this discrepancy by examining the sources that generate the target-detection process using electrocorticography (ECoG). We recorded ECoG activity from cortex in 14 patients undergoing epilepsy monitoring, as they performed an auditory or visual target-detection task. We examined target-related responses in 2 domains: high frequency band (HFB) activity and the P3b. Across tasks, we observed a greater proportion of electrodes that showed target-specific HFB power relative to P3b over frontal cortex, but their proportions over parietal cortex were comparable. Notably, there was minimal overlap in the electrodes that showed target-specific HFB and P3b activity. These results revealed that the target-detection process is characterized by at least 2 different neural markers with distinct cortical distributions. Our findings suggest that separate neural mechanisms are driving the differential patterns of activity observed in scalp EEG and neuroimaging studies, with the P3b reflecting EEG findings and HFB activity reflecting neuroimaging findings, highlighting the notion that target detection is not a unitary phenomenon. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Quantification of diphtheria toxin mediated ADP-ribosylation in a solid-phase assay.
Bachran, Christopher; Sutherland, Mark; Bachran, Diana; Fuchs, Hendrik
2007-09-01
Because of reduced vaccination programs, the number of diphtheria infections has increased in the last decade. Diphtheria toxin (DT) is expressed by Corynebacterium diphtheriae and is responsible for the lethality of diphtheria. DT inhibits cellular protein synthesis by ADP-ribosylation of the eukaryotic elongation factor 2 (eEF2). No in vitro system for the quantification of DT enzymatic activity exists. We developed a solid-phase assay for the specific detection of ADP-ribosylation by DT. Solid phase-bound his-tag eEF2 is ADP-ribosylated by toxins using biotinylated NAD(+) as substrate, and the transferred biotinylated ADP-ribose is detected by streptavidin-peroxidase. DT enzymatic activity correlated with absorbance. We measured the amount of ADP-ribosylated eEF2 after precipitation with streptavidin-Sepharose. Quantification was done after Western blotting and detection with anti-his-tag antibody using an LAS-1000 System. The assay detected enzymatically active DT at 30 ng/L, equivalent to 5 mU/L ADP-ribosylating activity. Pseudomonas exotoxin A (PE) activity was also detected at 100 ng/L. We verified the assay with chimeric toxins composed of the catalytic domain of DT or PE and a tumor-specific ligand. These chimeric toxins revealed increased signals at 1000 ng/L. Heat-inactivated DT and cholera toxin that ADP-ribosylates G-proteins did not show any signal increase. The assay may be the basis for the development of a routine diagnostic assay for the detection of DT activity and highly specific inhibitors of DT.
Steel bridge fatigue crack detection with piezoelectric wafer active sensors
NASA Astrophysics Data System (ADS)
Yu, Lingyu; Giurgiutiu, Victor; Ziehl, Paul; Ozevin, Didem; Pollock, Patrick
2010-04-01
Piezoelectric wafer active sensors (PWAS) are well known for its dual capabilities in structural health monitoring, acting as either actuators or sensors. Due to the variety of deterioration sources and locations of bridge defects, there is currently no single method that can detect and address the potential sources globally. In our research, our use of the PWAS based sensing has the novelty of implementing both passive (as acoustic emission) and active (as ultrasonic transducers) sensing with a single PWAS network. The combined schematic is using acoustic emission to detect the presence of fatigue cracks in steel bridges in their early stage since methods such as ultrasonics are unable to quantify the initial condition of crack growth since most of the fatigue life for these details is consumed while the fatigue crack is too small to be detected. Hence, combing acoustic emission with ultrasonic active sensing will strengthen the damage detection process. The integration of passive acoustic emission detection with active sensing will be a technological leap forward from the current practice of periodic and subjective visual inspection, and bridge management based primarily on history of past performance. In this study, extensive laboratory investigation is performed supported by theoretical modeling analysis. A demonstration system will be presented to show how piezoelectric wafer active sensor is used for acoustic emission. Specimens representing complex structures are tested. The results will also be compared with traditional acoustic emission transducers to identify the application barriers.
Telomerase activity in gastric cancer.
Hiyama, E; Yokoyama, T; Tatsumoto, N; Hiyama, K; Imamura, Y; Murakami, Y; Kodama, T; Piatyszek, M A; Shay, J W; Matsuura, Y
1995-08-01
Although many genetic alterations have been reported in gastric cancer, it is not known whether all gastric tumors are capable of indefinite proliferative potential, e.g., immortality. The expression of telomerase and stabilization of telomeres are concomitant with the attainment of immortality in tumor cells; thus, the measurement of telomerase activity in clinically obtained tumor samples may provide important information useful both as a diagnostic marker to detect immortal cancer cells in clinical materials and as a prognostic indicator of patient outcome. Telomerase activity was analyzed in 66 primary gastric cancers with the use of a PCR-based assay. The majority of tumors (85%) displayed telomerase activity, but telomerase was undetectable in 10 tumors (15%), 8 of which were early stage tumors. Most of the tumors with telomerase activity were large and of advanced stages, including metastases. Survival rate of patients of tumors with detectable telomerase activity was significantly shorter than that of those without telomerase activity. Alterations of telomere length (reduced/elongated terminal restriction fragments) were detected in 14 of 66 (21%) gastric cancers, and all 14 had telomerase activity. Cellular DNA contents revealed that all 22 aneuploid tumors had detectable telomerase activity. The present results indicate that telomerase activation may be required as a critical step in the multigenetic process of tumorigenesis, and that telomerase is frequently but not always activated as a late event in gastric cancer progression.
Dassanayake, Rohana P; Orrú, Christina D; Hughson, Andrew G; Caughey, Byron; Graça, Telmo; Zhuang, Dongyue; Madsen-Bouterse, Sally A; Knowles, Donald P; Schneider, David A
2016-03-01
Real-time quaking-induced conversion (RT-QuIC) is a rapid, specific and highly sensitive prion seeding activity detection assay that uses recombinant prion protein (rPrPSen) to detect subinfectious levels of the abnormal isoforms of the prion protein (PrPSc). Although RT-QuIC has been successfully used to detect PrPSc in various tissues from humans and animals, including sheep, tissues from goats infected with classical scrapie have not yet been tested. Therefore, the aims of the present study were to (1) evaluate whether prion seeding activity could be detected in the brain tissues of goats with scrapie using RT-QuIC, (2) optimize reaction conditions to improve scrapie detection in goats, and (3) compare the performance of RT-QuIC for the detection of PrPSc with the more commonly used ELISA and Western blot assays. We further optimized RT-QuIC conditions for sensitive and specific detection of goat scrapie seeding activity in brain tissue from clinical animals. When used with 200 mM sodium chloride, both full-length sheep rPrPSen substrates (PrP genotypes A136R154Q171 and V136R154Q171) provided good discrimination between scrapie-infected and normal goat brain samples at 10(- )3 dilution within 15 h. Our findings indicate that RT-QuIC was at least 10,000-fold more sensitive than ELISA and Western blot assays for the detection of scrapie seeding activity in goat brain samples. In addition to PRNP WT samples, positive RT-QuIC reactions were also observed with three PRNP polymorphic goat brain samples (G/S127, I/M142 and H/R143) tested. Taken together, these findings demonstrate that RT-QuIC sensitively detects prion seeding activity in classical scrapie-infected goat brain samples.
Dassanayake, Rohana P.; Orrú, Christina D.; Hughson, Andrew G.; Caughey, Byron; Graça, Telmo; Zhuang, Dongyue; Madsen-Bouterse, Sally A.; Knowles, Donald P.; Schneider, David A.
2016-01-01
Real-time quaking-induced conversion (RT-QuIC) is a rapid, specific and highly sensitive prion seeding activity detection assay that uses recombinant prion protein (rPrPSen) to detect subinfectious levels of the abnormal isoforms of the prion protein (PrPSc). Although RT-QuIC has been successfully used to detect PrPSc in various tissues from humans and animals, including sheep, tissues from goats infected with classical scrapie have not yet been tested. Therefore, the aims of the present study were to (1) evaluate whether prion seeding activity could be detected in the brain tissues of goats with scrapie using RT-QuIC, (2) optimize reaction conditions to improve scrapie detection in goats, and (3) compare the performance of RT-QuIC for the detection of PrPSc with the more commonly used ELISA and Western blot assays. We further optimized RT-QuIC conditions for sensitive and specific detection of goat scrapie seeding activity in brain tissue from clinical animals. When used with 200 mM sodium chloride, both full-length sheep rPrPSen substrates (PrP genotypes A136R154Q171 and V136R154Q171) provided good discrimination between scrapie-infected and normal goat brain samples at 10− 3 dilution within 15 h. Our findings indicate that RT-QuIC was at least 10 000-fold more sensitive than ELISA and Western blot assays for the detection of scrapie seeding activity in goat brain samples. In addition to PRNP WT samples, positive RT-QuIC reactions were also observed with three PRNP polymorphic goat brain samples (G/S127, I/M142 and H/R143) tested. Taken together, these findings demonstrate that RT-QuIC sensitively detects prion seeding activity in classical scrapie-infected goat brain samples. PMID:26653410
In vivo stepwise multi-photon activation fluorescence imaging of melanin in human skin
NASA Astrophysics Data System (ADS)
Lai, Zhenhua; Gu, Zetong; Abbas, Saleh; Lowe, Jared; Sierra, Heidy; Rajadhyaksha, Milind; DiMarzio, Charles
2014-03-01
The stepwise multi-photon activated fluorescence (SMPAF) of melanin is a low cost and reliable method of detecting melanin because the activation and excitation can be a continuous-wave (CW) mode near infrared (NIR) laser. Our previous work has demonstrated the melanin SMPAF images in sepia melanin, mouse hair, and mouse skin. In this study, we show the feasibility of using SMPAF to detect melanin in vivo. in vivo melanin SMPAF images of normal skin and benign nevus are demonstrated. SMPAF images add specificity for melanin detection than MPFM images and CRM images. Melanin SMPAF is a promising technology to enable early detection of melanoma for dermatologists.
A novel bicistronic sensor vector for detecting caspase-3 activation.
Vagner, Tatyana; Mouravlev, Alexandre; Young, Deborah
2015-01-01
Apoptosis is involved in pathological cell death of a wide range of human diseases. One of the most important biochemical markers of apoptosis is activation of caspase-3. Ability to detect caspase-3 activation early in the pathological process is important for determining the timing for interfering with apoptosis initiation and prevention of cell damage. Techniques allowing detection of caspase-3 activity at a single cell level show increased sensitivity, compared to biochemical assays; therefore, we developed a novel bicistronic caspase-3 sensor vector enabling detection of caspase-3 activity in individual cells. We employed green fluorescent protein (GFP) as a reporter for caspase-3 activation in our constructs and assessed the functionality of the generated constructs in transiently transfected Neuro2A and HEK293 cells under basal conditions and following application of okadaic acid (OA) or staurosporine (STS) to induce apoptosis. To ensure responsiveness of the new sensor vector to active caspase-3, we co-transfected the sensor with plasmid(s) overexpressing active caspase-3 and quantified GFP fluorescence using a plate reader. We observed an increase in GFP expression in cells transfected with the new bicistronic caspase-3 sensor in response to both OA and STS. We also showed a significant increase in GFP fluorescence intensity in cells co-expressing the sensor with the plasmid(s) encoding active caspase-3. We generated a novel bicistronic caspase-3 sensor vector which relies on a transcription factor/response element system. The obtained sensor combines high sensitivity of the single cell level detection with the possibility of automated quantification. Copyright © 2015 Elsevier Inc. All rights reserved.
2006-06-01
and cell growth and differentiation (14). Increased ARG activity has long been detected in pa- tients with colon, breast , lung, and prostate cancer ...activity has long been detected in patients with colon, breast , lung and prostate cancer [23] and it was advanced that this enzymatic activity...AD_________________ Award Number: DAMD 17-03-01-0032 TITLE: Human Prostate Cancer Infiltrating
Coleman, Laci S.; Ford, W. Mark; Dobony, Christopher A.; Britzke, Eric R.
2014-01-01
In the summers of 2011 and 2012, we compared passive and active acoustic sampling for bats at 31 sites at Fort Drum Military Installation, New York. We defined active sampling as acoustic sampling that occurred in 30-min intervals between the hours of sunset and 0200 with a user present to manipulate the directionality of the microphone. We defined passive sampling as acoustic sampling that occurred over a 12-h period (1900–0700 hours) without a user present and with the microphone set in a predetermined direction. We detected seven of the nine possible species at Fort Drum, including the federally endangered Indiana bat Myotis sodalis, the proposed-for-listing northern bat M. septentrionalis, the little brown bat M. lucifugus, and the big brown bat Eptesicus fuscus, which are impacted by white-nose syndrome (WNS); and the eastern red bat Lasiurus borealis, the hoary bat L. cinereus, and the silver-haired bat Lasionycteris noctivagans, which are not known to be impacted by WNS. We did not detect two additional WNS-impacted species known to historically occur in the area: the eastern small-footed bat Myotis leibii and the tri-colored bat Perimyotis subflavus. Single-season occupancy models revealed lower detection probabilities of all detected species using active sampling versus passive sampling. Additionally, overall detection probabilities declined in detected WNS-impacted species between years. A paired t-test of simultaneous sampling on 21 occasions revealed that overall recorded foraging activity per hour was greater using active than passive sampling for big brown bats and greater using passive than active sampling for little brown bats. There was no significant difference in recorded activity between methods for other WNS-impacted species, presumably because these species have been so reduced in number that their “apparency” on the landscape is lower. Finally, a cost analysis of standard passive and active sampling protocols revealed that passive sampling is substantially more cost-effective than active sampling per hour of data collection. We recommend passive sampling over active sampling methodologies as they are defined in our study for detection probability and/or occupancy studies focused on declining bat species in areas that have experienced severe WNS-associated impacts.
Choi, Seeyoung; Love, Paul E
2018-01-05
Oxidative inactivation of cysteine-dependent Protein Tyrosine Phosphatases (PTPs) by cellular reactive oxygen species (ROS) plays a critical role in regulating signal transduction in multiple cell types. The phosphatase activity of most PTPs depends upon a 'signature' cysteine residue within the catalytic domain that is maintained in the de-protonated state at physiological pH rendering it susceptible to ROS-mediated oxidation. Direct and indirect techniques for detection of PTP oxidation have been developed (Karisch and Neel, 2013). To detect catalytically active PTPs, cell lysates are treated with iodoacetyl-polyethylene glycol-biotin (IAP-biotin), which irreversibly binds to reduced (S - ) cysteine thiols. Irreversible oxidation of SHP-1 after treatment of cells with pervanadate or H 2 O 2 is detected with antibodies specific for the sulfonic acid (SO 3 H) form of the conserved active site cysteine of PTPs. In this protocol, we describe a method for the detection of the reduced (S - ; active) or irreversibly oxidized (SO 3 H; inactive) form of the hematopoietic PTP SHP-1 in thymocytes, although this method is applicable to any cysteine-dependent PTP in any cell type.
NMDA Receptor Activity in Circulating Red Blood Cells: Methods of Detection.
Makhro, Asya; Kaestner, Lars; Bogdanova, Anna
2017-01-01
Abundance and activity of N-methyl-D-aspartate (NMDA) in circulating red blood cells contributes to the maintenance of intracellular Ca 2+ in these cells and, by doing that, controls red cell volume, membrane stability, and O 2 carrying capacity. Detection of the NMDA receptor activity in red blood cells is challenging as the number of its copies is low and shows substantial cell-to-cell heterogeneity. Receptor abundance is reliably assessed using the radiolabeled antagonist ([ 3 H]MK-801) binding technique. Uptake of Ca 2+ following the NMDA receptor activation is detected in cells loaded with Ca 2+ -sensitive fluorescent dye Fluo-4 AM. Both microfluorescence live-cell imaging and flow cytometry may be used for fluorescence intensity detection. Automated patch clamp is currently used for recording of electric currents triggered by the stimulation of the NMDA receptor. These currents are mediated by the Ca 2+ -sensitive K + (Gardos) channels that open upon Ca 2+ uptake via the active NMDA receptor. Furthermore, K + flux through the Gardos channels induced by the NMDA receptor stimulation in red blood cells may be detected using unidirectional K + ( 86 Rb + ) influx.
Detection of subtle nocturnal motor activity from 3-D accelerometry recordings in epilepsy patients.
Nijsen, Tamara M E; Cluitmans, Pierre J M; Arends, Johan B A M; Griep, Paul A M
2007-11-01
This paper presents a first step towards reliable detection of nocturnal epileptic seizures based on 3-D accelerometry (ACM) recordings. The main goal is to distinguish between data with and without subtle nocturnal motor activity, thus reducing the amount of data that needs further (more complex) analysis for seizure detection. From 15 ACM signals (measured on five positions on the body), two features are computed, the variance and the jerk. In the resulting 2-D feature space, a linear threshold function is used for classification. For training and testing, the algorithm ACM data along with video data is used from nocturnal registrations in seven mentally retarded patients with severe epilepsy. Per patient, the algorithm detected 100% of the periods of motor activity that are marked in video recordings and the ACM signals by experts. From all the detections, 43%-89% was correct (mean =65%). We were able to reduce the amount of data that need to be analyzed considerably. The results show that our approach can be used for detection of subtle nocturnal motor activity. Furthermore, our results indicate that our algorithm is robust for fluctuations across patients. Consequently, there is no need for training the algorithm for each new patient.
Peng, Juan; Han, Xiao-Xia; Zhang, Qing-Chun; Yao, Hui-Qin; Gao, Zuo-Ning
2015-06-09
Copper sulfide nanoparticle-decorated graphene sheet (CuS/GR) was successfully synthesized and used as a signal amplification platform for electrochemical detection of alkaline phosphatase activity. First, CuS/GR was prepared through a microwave-assisted hydrothermal approach. The CuS/GR nanocomposites exhibited excellent electrocatalytic activity toward the oxidation of ALP hydrolyzed products such as 1-naphthol, which produced a current response. Thus, a catalytic amplification platform based on CuS/GR nanocomposite for electrochemical detection of ALP activity was designed using 1-naphthyl phosphate as a model substrate. The current response increased linearly with ALP concentration from 0.1 to 100 U L(-1) with a detection limit of 0.02 U L(-1). The assay was applied to estimate ALP activity in human serum samples with satisfactory results. This strategy may find widespread and promising applications in other sensing systems that involves ALP. Copyright © 2015 Elsevier B.V. All rights reserved.
FDG-PET detects nonuniform muscle activity in the lower body during human gait.
Kindred, John H; Ketelhut, Nathaniel B; Benson, John-Michael; Rudroff, Thorsten
2016-11-01
Nonuniform muscle activity has been partially explained by anatomically defined neuromuscular compartments. The purpose of this study was to investigate the uniformity of skeletal muscle activity during walking. Eight participants walked at a self-selected speed, and muscle activity was quantified using [ 18 F]-fluorodeoxyglucose positron emission tomography imaging. Seventeen muscles were divided into 10 equal length sections, and within muscle activity was compared. Nonuniform activity was detected in 12 of 17 muscles (ƒ > 4.074; P < 0.046), which included both uni- and multi-articular muscles. Greater proximal activity was detected in 6 muscles (P < 0.049), and greater distal versus medial activity was found in the iliopsoas (P < 0.042). Nonuniform muscle activity is likely related to recruitment of motor units located within separate neuromuscular compartments. These findings indicate that neuromuscular compartments are recruited selectively to allow for efficient energy transfer, and these patterns may be task-dependent. Muscle Nerve 54: 959-966, 2016. © 2016 Wiley Periodicals, Inc.
Camacho-Morales, Reyna Lucero; Zazueta-Novoa, Vanesa; Casillas, Juana Lizbeth González; Ballesteros, Elizabeth Aranda; Bote, Juan Antonio Ocampo; Zazueta-Sandoval, Roberto
2014-05-01
We detected NADP(+)-dependent dihydrodiol dehydrogenase (DD) activity in a cell-free extract from Mucor circinelloides YR-1, after high-speed centrifugation. We analyzed the enzymatic activity in the cytosolic fraction by zymograms, as described previously, and eight different DD activity bands were revealed. Five constitutive DD activities (DD1-5) were present when glucose was used as carbon source and three inducible activities (NDD, PDD1 and PDD2) when aromatic hydrocarbon compounds were used. NDD activity was induced all of the aromatic hydrocarbon compounds. The highest DD activity inducer was naphthalene and the lowest was pyrene. One of the enzymes showed higher activity with cis-naphthalene-diol rather than with trans-nahthalenediol as a substrate. We purified this particular enzyme to homogeneity and found that it had an isoelectric point of 4.6. The molecular weight for the native protein was 197.4kDa and 49.03±0.5kDa for the monomer that conforms it, suggesting a homotetrameric structure for the complete enzyme. Polyclonal antibodies were raised against it and obtained. NDD activity was almost totally inhibited when antibodies were used at low concentrations, and in native immunoblots only one band, which corresponds to the activity band detected in the zymograms, could be detected. In denaturing PAGE immunoblots only one band was detected. This band corresponds to the purified protein band of 49kDa detected in SDS-PAGE gels. The other two inducible enzymes PDD1 and PDD2 were present only when phenanthrene was used as sole carbon source in the culture media. Copyright © 2014 Elsevier Inc. All rights reserved.
DHS Summary Report -- Robert Weldon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weldon, Robert A.
This summer I worked on benchmarking the Lawrence Livermore National Laboratory fission multiplicity capability used in the Monte Carlo particle transport code MCNPX. This work involved running simulations and then comparing the simulation results with experimental experiments. Outlined in this paper is a brief description of the work completed this summer, skills and knowledge gained, and how the internship has impacted my planning for the future. Neutron multiplicity counting is a neutron detection technique that leverages the multiplicity emissions of neutrons from fission to identify various actinides in a lump of material. The identification of individual actinides in lumps ofmore » material crossing our boarders, especially U-235 and Pu-239, is a key component for maintaining the safety of the country from nuclear threats. Several multiplicity emission options from spontaneous and induced fission already existed in MCNPX 2.4.0. These options can be accessed through use of the 6th entry on the PHYS:N card. Lawrence Livermore National Laboratory (LLNL) developed a physics model for the simulation of neutron and gamma ray emission from fission and photofission that was included in MCNPX 2.7.B as an undocumented feature and then was documented in MCNPX 2.7.C. The LLNL multiplicity capability provided a different means for MCNPX to simulate neutron and gamma-ray distributions for neutron induced, spontaneous and photonuclear fission reactions. The original testing on the model for implementation into MCNPX was conducted by Gregg McKinney and John Hendricks. The model is an encapsulation of measured data of neutron multiplicity distributions from Gwin, Spencer, and Ingle, along with the data from Zucker and Holden. One of the founding principles of MCNPX was that it would have several redundant capabilities, providing the means of testing and including various physics packages. Though several multiplicity sampling methodologies already existed within MCNPX, the LLNL fission multiplicity was included to provide a separate capability for computing multiplicity as well as including several new features not already included in MCNPX. These new features include: (1) prompt gamma emission/multiplicity from neutron-induced fission; (2) neutron multiplicity and gamma emission/multiplicity from photofission; and (3) an option to enforce energy correlation for gamma neutron multiplicity emission. These new capabilities allow correlated signal detection for identifying presence of special nuclear material (SNM). Therefore, these new capabilities help meet the missions of the Domestic Nuclear Detection Office (DNDO), which is tasked with developing nuclear detection strategies for identifying potential radiological and nuclear threats, by providing new simulation capability for detection strategies that leverage the new available physics in the LLNL multiplicity capability. Two types of tests were accomplished this summer to test the default LLNL neutron multiplicity capability: neutron-induced fission tests and spontaneous fission tests. Both cases set the 6th entry on the PHYS:N card to 5 (i.e. use LLNL multiplicity). The neutron-induced fission tests utilized a simple 0.001 cm radius sphere where 0.0253 eV neutrons were released at the sphere center. Neutrons were forced to immediately collide in the sphere and release all progeny from the sphere, without further collision, using the LCA card, LCA 7j -2 (therefore density and size of the sphere were irrelevant). Enough particles were run to ensure that the average error of any specific multiplicity did not exceed 0.36%. Neutron-induced fission multiplicities were computed for U-233, U-235, Pu-239, and Pu-241. The spontaneous fission tests also used the same spherical geometry, except: (1) the LCA card was removed; (2) the density of the sphere was set to 0.001 g/cm3; and (3) instead of emitting a thermal neutron, the PAR keyword was set to PAR=SF. The purpose of the small density was to ensure that the spontaneous fission neutrons would not further interact and induce fissions (i.e. the mean free path greatly exceeded the size of the sphere). Enough particles were run to ensure that the average error of any specific spontaneous multiplicity did not exceed 0.23%. Spontaneous fission multiplicities were computed for U-238, Pu-238, Pu-240, Pu-242, Cm-242, and Cm-244. All of the computed results were compared against experimental results compiled by Holden at Brookhaven National Laboratory.« less
Nanoparticle detection using dual-phase interferometry
Deutsch, Bradley; Beams, Ryan; Novotny, Lukas
2013-01-01
Detection and identification of nanoparticles is of growing interest in atmospheric monitoring, medicine and semiconductor manufacturing. While elastic light scattering with interferometric detection provides good sensitivity to single particles, active optical components prevent scalability realistic sizes for deployment in the field or clinic. Here we report on a simple phase-sensitive nanoparticle detection scheme with no active optical elements. Two measurements are taken simultaneously, allowing amplitude and phase to be decoupled. We demonstrate detection of 25 nm Au particles in liquid in Δt ~ 1 ms with a signal-to-noise ratio of 37. Such performance makes it possible to detect nanoscale contaminants or larger proteins in real time without the need of artificial labeling. PMID:20830181
Electrochemically mediated polymerization for highly sensitive detection of protein kinase activity.
Hu, Qiong; Wang, Qiangwei; Jiang, Cuihua; Zhang, Jian; Kong, Jinming; Zhang, Xueji
2018-07-01
Protein kinases play a pivotal role in cellular regulation and signal transduction, the detection of protein kinase activity and inhibition is therefore of great importance to clinical diagnosis and drug discovery. In this work, a novel electrochemical platform using the electrochemically mediated polymerization as an efficient and cost-effective signal amplification strategy is described for the highly sensitive detection of protein kinase activity. This platform involves 1) the phosphorylation of substrate peptide by protein kinase, 2) the attachment of alkyl halide to the phosphorylated sites via the carboxylate-Zr 4+ -phosphate chemistry, and 3) the in situ grafting of electroactive polymers from the phosphorylated sites through the electrochemically mediated atom transfer radical polymerization (eATRP) at a negative potential, in the presence of the surface-attached alkyl halide as the initiator and the electroactive tag-conjugated acrylate as the monomer, respectively. Due to the electrochemically mediated polymerization, a large number of electroactive tags can be linked to each phosphorylated site, thereby greatly improving the detection sensitivity. This platform has been successfully applied to detect the activity of cAMP-dependent protein kinase (PKA) with a detection limit down to 1.63 mU mL -1 . Results also demonstrate that it is highly selective and can be used for the screening of protein kinase inhibitors. The potential application of our platform for protein kinase activity detection in complex biological samples has been further verified using normal human serum and HepG2 cell lysate. Moreover, our platform is operationally simple, highly efficient and cost-effective, thus holding great potential in protein kinase detection and inhibitor screening. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liewer, P. C.; Qiu, J.; Lindsey, C.
2017-10-01
Seismic maps of the Sun's far hemisphere, computed from Doppler data from the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) are now being used routinely to detect strong magnetic regions on the far side of the Sun (http://jsoc.stanford.edu/data/farside/). To test the reliability of this technique, the helioseismically inferred active region detections are compared with far-side observations of solar activity from the Solar TErrestrial RElations Observatory (STEREO), using brightness in extreme-ultraviolet light (EUV) as a proxy for magnetic fields. Two approaches are used to analyze nine months of STEREO and HMI data. In the first approach, we determine whether new large east-limb active regions are detected seismically on the far side before they appear Earth side and study how the detectability of these regions relates to their EUV intensity. We find that while there is a range of EUV intensities for which far-side regions may or may not be detected seismically, there appears to be an intensity level above which they are almost always detected and an intensity level below which they are never detected. In the second approach, we analyze concurrent extreme-ultraviolet and helioseismic far-side observations. We find that 100% (22) of the far-side seismic regions correspond to an extreme-ultraviolet plage; 95% of these either became a NOAA-designated magnetic region when reaching the east limb or were one before crossing to the far side. A low but significant correlation is found between the seismic signature strength and the EUV intensity of a far-side region.
Ngan, Shing-Chung; Hu, Xiaoping; Khong, Pek-Lan
2011-03-01
We propose a method for preprocessing event-related functional magnetic resonance imaging (fMRI) data that can lead to enhancement of template-free activation detection. The method is based on using a figure of merit to guide the wavelet shrinkage of a given fMRI data set. Several previous studies have demonstrated that in the root-mean-square error setting, wavelet shrinkage can improve the signal-to-noise ratio of fMRI time courses. However, preprocessing fMRI data in the root-mean-square error setting does not necessarily lead to enhancement of template-free activation detection. Motivated by this observation, in this paper, we move to the detection setting and investigate the possibility of using wavelet shrinkage to enhance template-free activation detection of fMRI data. The main ingredients of our method are (i) forward wavelet transform of the voxel time courses, (ii) shrinking the resulting wavelet coefficients as directed by an appropriate figure of merit, (iii) inverse wavelet transform of the shrunk data, and (iv) submitting these preprocessed time courses to a given activation detection algorithm. Two figures of merit are developed in the paper, and two other figures of merit adapted from the literature are described. Receiver-operating characteristic analyses with simulated fMRI data showed quantitative evidence that data preprocessing as guided by the figures of merit developed in the paper can yield improved detectability of the template-free measures. We also demonstrate the application of our methodology on an experimental fMRI data set. The proposed method is useful for enhancing template-free activation detection in event-related fMRI data. It is of significant interest to extend the present framework to produce comprehensive, adaptive and fully automated preprocessing of fMRI data optimally suited for subsequent data analysis steps. Copyright © 2010 Elsevier B.V. All rights reserved.
New ELISA-based method for the detection of O-GlcNAc transferase activity in vitro.
Qi, Jieqiong; Wang, Ruihong; Zeng, Yazhen; Yu, Wengong; Gu, Yuchao
2017-08-09
O-GlcNAcylation is a dynamic, reversible, post-translational modification that regulates many cellular processes. O-GlcNAc transferase (OGT) is the sole enzyme transferring N-acetylglucosamine from uridine diphosphate (UDP)-GlcNAc to selected serine/threonine residues of cytoplasm and nucleus proteins. Aberrant of OGT activity is associated with several diseases, suggesting OGT as a novel therapeutic target. In this study, we created a new enzyme linked immunosorbent assays (ELISA)-based method for detection of OGT activity. First, casein kinase II (CKII), a well-known OGT substrate, was coated onto ELISA plate. Second, the GlcNAc transferred by OGT from UDP-GlcNAc to CKII was detected using an antibody to O-GlcNAc and then the horseradish peroxidase (HRP)-labeled secondary antibody. At last, 3,3',5,5'-tetramethylbenzidine (TMB), the substrate of HRP, was used to detect the O-GlcNAcylation level of CKII which reflected the activity of OGT. Based on a series of optimization experiments, the RL2 antibody was selected for O-GlcNAc detection and the concentrations of CKII, OGT, and UDP-GlcNAc were determined in this study. ST045849, a commercial OGT inhibitor, was used to verify the functionality of the system. Altogether, this study showed a method that could be applied to detect OGT activity and screen OGT inhibitors.
Evaluation of harmonic direction-finding systems for detecting locomotor activity
Boyarski, V.L.; Rodda, G.H.; Savidge, J.A.
2007-01-01
We conducted a physical simulation experiment to test the efficacy of harmonic direction finding for remotely detecting locomotor activity in animals. The ability to remotely detect movement helps to avoid disturbing natural movement behavior. Remote detection implies that the observer can sense only a change in signal bearing. In our simulated movements, small changes in bearing (<5.7??) were routinely undetectable. Detectability improved progressively with the size of the simulated animal movement. The average (??SD) of reflector tag movements correctly detected for 5 observers was 93.9 ?? 12.8% when the tag was moved ???11.5??; most observers correctly detected tag movements ???20.1??. Given our data, one can assess whether the technique will be effective for detecting movements at an observation distance appropriate for the study organism. We recommend that both habitat and behavior of the organism be taken into consideration when contemplating use of this technique for detecting locomotion.
Behavior Analysis Based on Coordinates of Body Tags
NASA Astrophysics Data System (ADS)
Luštrek, Mitja; Kaluža, Boštjan; Dovgan, Erik; Pogorelc, Bogdan; Gams, Matjaž
This paper describes fall detection, activity recognition and the detection of anomalous gait in the Confidence project. The project aims to prolong the independence of the elderly by detecting falls and other types of behavior indicating a health problem. The behavior will be analyzed based on the coordinates of tags worn on the body. The coordinates will be detected with radio sensors. We describe two Confidence modules. The first one classifies the user's activity into one of six classes, including falling. The second one detects walking anomalies, such as limping, dizziness and hemiplegia. The walking analysis can automatically adapt to each person by using only the examples of normal walking of that person. Both modules employ machine learning: the paper focuses on the features they use and the effect of tag placement and sensor noise on the classification accuracy. Four tags were enough for activity recognition accuracy of over 93% at moderate sensor noise, while six were needed to detect walking anomalies with the accuracy of over 90%.
An Improved Harmonic Current Detection Method Based on Parallel Active Power Filter
NASA Astrophysics Data System (ADS)
Zeng, Zhiwu; Xie, Yunxiang; Wang, Yingpin; Guan, Yuanpeng; Li, Lanfang; Zhang, Xiaoyu
2017-05-01
Harmonic detection technology plays an important role in the applications of active power filter. The accuracy and real-time performance of harmonic detection are the precondition to ensure the compensation performance of Active Power Filter (APF). This paper proposed an improved instantaneous reactive power harmonic current detection algorithm. The algorithm uses an improved ip -iq algorithm which is combined with the moving average value filter. The proposed ip -iq algorithm can remove the αβ and dq coordinate transformation, decreasing the cost of calculation, simplifying the extraction process of fundamental components of load currents, and improving the detection speed. The traditional low-pass filter is replaced by the moving average filter, detecting the harmonic currents more precisely and quickly. Compared with the traditional algorithm, the THD (Total Harmonic Distortion) of the grid currents is reduced from 4.41% to 3.89% for the simulations and from 8.50% to 4.37% for the experiments after the improvement. The results show the proposed algorithm is more accurate and efficient.
SERS-active ZnO/Ag hybrid WGM microcavity for ultrasensitive dopamine detection
NASA Astrophysics Data System (ADS)
Lu, Junfeng; Xu, Chunxiang; Nan, Haiyan; Zhu, Qiuxiang; Qin, Feifei; Manohari, A. Gowri; Wei, Ming; Zhu, Zhu; Shi, Zengliang; Ni, Zhenhua
2016-08-01
Dopamine (DA) is a potential neuro modulator in the brain which influences a variety of motivated behaviors and plays a key role in life science. A hybrid ZnO/Ag microcavity based on Whispering Gallery Mode (WGM) effect has been developed for ultrasensitive detection of dopamine. Utilizing this effect of structural cavity mode, a Raman signal of R6G (5 × 10-3 M) detected by this designed surface-enhanced Raman spectroscopy (SERS)-active substrate was enhanced more than 10-fold compared with that of ZnO film/Ag substrate. Also, this hybrid microcavity substrate manifests high SERS sensitivity to rhodamine 6 G and detection limit as low as 10-12 M to DA. The Localized Surface Plasmons of Ag nanoparticles and WGM-enhanced light-matter interaction mainly contribute to the high SERS sensitivity and help to achieve a lower detection limit. This designed SERS-active substrate based on the WGM effect has the potential for detecting neurotransmitters in life science.
Neural correlates of change detection and change blindness in a working memory task.
Pessoa, Luiz; Ungerleider, Leslie G
2004-05-01
Detecting changes in an ever-changing environment is highly advantageous, and this ability may be critical for survival. In the present study, we investigated the neural substrates of change detection in the context of a visual working memory task. Subjects maintained a sample visual stimulus in short-term memory for 6 s, and were asked to indicate whether a subsequent, test stimulus matched or did not match the original sample. To study change detection largely uncontaminated by attentional state, we compared correct change and correct no-change trials at test. Our results revealed that correctly detecting a change was associated with activation of a network comprising parietal and frontal brain regions, as well as activation of the pulvinar, cerebellum, and inferior temporal gyrus. Moreover, incorrectly reporting a change when none occurred led to a very similar pattern of activations. Finally, few regions were differentially activated by trials in which a change occurred but subjects failed to detect it (change blindness). Thus, brain activation was correlated with a subject's report of a change, instead of correlated with the physical change per se. We propose that frontal and parietal regions, possibly assisted by the cerebellum and the pulvinar, might be involved in controlling the deployment of attention to the location of a change, thereby allowing further processing of the visual stimulus. Visual processing areas, such as the inferior temporal gyrus, may be the recipients of top-down feedback from fronto-parietal regions that control the reactive deployment of attention, and thus exhibit increased activation when a change is reported (irrespective of whether it occurred or not). Whereas reporting that a change occurred, be it correctly or incorrectly, was associated with strong activation in fronto-parietal sites, change blindness appears to involve very limited territories.
Wen, Yingxia; Palladino, Giuseppe; Xie, Yuhong; Ferrari, Annette; Ma, Xiuwen; Han, Liqun; Dormitzer, Philip R; Settembre, Ethan C
2016-06-17
Influenza vaccines are the primary intervention to prevent the substantial health burden of seasonal and pandemic influenza. Subunit and split influenza vaccines are formulated, released for clinical use, and tested for stability based on their content of immunologically active (capable of eliciting functional antibodies) hemagglutinin (HA). Single-radial immunodiffusion (SRID), the standard in vitro potency assay in the field, is believed to specifically detect immunologically active HA. We confirmed that, with conformationally homogeneous HA preparations, SRID specifically detected native, pre-fusion HA, which elicited influenza neutralizing and hemagglutination inhibiting (HI) antibodies in mice, and it did not detect low-pH stressed, post-fusion HA, which was selectively removed from the SRID gel during a blotting step and was significantly less immunologically active. This selective detection was due to the SRID format, not a conformational specificity of the sheep antiserum used in the SRID, as the same antiserum detected non-stressed and low-pH stressed HA similarly when used in an ELISA format. However, when low-pH stressed HA was mixed with non-stressed HA, SRID detected both forms in mixed immunoprecipitin rings, leading to over-quantification of pre-fusion HA. We previously reported that trypsin digestion of antigen samples selectively degrade stressed HA, so that an otherwise conformationally insensitive biophysical quantification technique, reversed-phase high pressure liquid chromatography (RP-HPLC), can specifically quantify trypsin-resistant, immunologically active, pre-fusion HA. Here, we report that trypsin digestion can also improve the specificity of SRID so that it can quantify immunologically active, pre-fusion HA when it is mixed with less immunologically active, post-fusion HA. Copyright © 2016 Elsevier Ltd. All rights reserved.
SWAN - Detection of explosives by means of fast neutron activation analysis
NASA Astrophysics Data System (ADS)
Gierlik, M.; Borsuk, S.; Guzik, Z.; Iwanowska, J.; Kaźmierczak, Ł.; Korolczuk, S.; Kozłowski, T.; Krakowski, T.; Marcinkowski, R.; Swiderski, L.; Szeptycka, M.; Szewiński, J.; Urban, A.
2016-10-01
In this work we report on SWAN, the experimental, portable device for explosives detection. The device was created as part of the EU Structural Funds Project "Accelerators & Detectors" (POIG.01.01.02-14-012/08-00), with the goal to increase beneficiary's expertise and competencies in the field of neutron activation analysis. Previous experiences and budged limitations lead toward a less advanced design based on fast neutron interactions and unsophisticated data analysis with the emphasis on the latest gamma detection and spectrometry solutions. The final device has been designed as a portable, fast neutron activation analyzer, with the software optimized for detection of carbon, nitrogen and oxygen. SWAN's performance in the role of explosives detector is elaborated in this paper. We demonstrate that the unique features offered by neutron activation analysis might not be impressive enough when confronted with practical demands and expectations of a generic homeland security customer.
Universal fieldable assay with unassisted visual detection
NASA Technical Reports Server (NTRS)
Chelyapov, Nicolas (Inventor)
2012-01-01
A universal detection system based on allosteric aptamers, signal amplification cascade, and eye-detectable phrase transition. A broadly applicable homogeneous detection system is provided. It utilizes components of the blood coagulation cascade in the presence of polystyrene microspheres (MS) as a signal amplifier. Russell's viper venom factor X activator (RVV-X) triggers the cascade, which results in an eye-visible phase transition--precipitation of MS bound to clotted fibrin. An allosteric RNA aptamer, RNA132, with affinity for RVV-X and human vascular endothelial growth factor (VEGF.sub.165) was created. RNA132 inhibits enzymatic activity of RVV-X. The effector molecule, VEGF.sub.165, reverses the inhibitory activity of RNA132 on RVV-X and restores its enzymatic activity, thus triggering the cascade and enabling the phase transition. Similar results were obtained for another allosteric aptamer modulated by a protein tyrosine phosphatase. The assay is instrumentation-free for both processing and readout.
Integrating conflict detection and attentional control mechanisms.
Walsh, Bong J; Buonocore, Michael H; Carter, Cameron S; Mangun, George R
2011-09-01
Human behavior involves monitoring and adjusting performance to meet established goals. Performance-monitoring systems that act by detecting conflict in stimulus and response processing have been hypothesized to influence cortical control systems to adjust and improve performance. Here we used fMRI to investigate the neural mechanisms of conflict monitoring and resolution during voluntary spatial attention. We tested the hypothesis that the ACC would be sensitive to conflict during attentional orienting and influence activity in the frontoparietal attentional control network that selectively modulates visual information processing. We found that activity in ACC increased monotonically with increasing attentional conflict. This increased conflict detection activity was correlated with both increased activity in the attentional control network and improved speed and accuracy from one trial to the next. These results establish a long hypothesized interaction between conflict detection systems and neural systems supporting voluntary control of visual attention.
Justen, Christoph; Herbert, Cornelia
2018-04-19
Numerous studies have investigated the neural underpinnings of passive and active deviance and target detection in the well-known auditory oddball paradigm by means of event-related potentials (ERPs) or functional magnetic resonance imaging (fMRI). The present auditory oddball study investigates the spatio-temporal dynamics of passive versus active deviance and target detection by analyzing amplitude modulations of early and late ERPs while at the same time exploring the neural sources underling this modulation with standardized low-resolution brain electromagnetic tomography (sLORETA) . A 64-channel EEG was recorded from twelve healthy right-handed participants while listening to 'standards' and 'deviants' (500 vs. 1000 Hz pure tones) during a passive (block 1) and an active (block 2) listening condition. During passive listening, participants had to simply listen to the tones. During active listening they had to attend and press a key in response to the deviant tones. Passive and active listening elicited an N1 component, a mismatch negativity (MMN) as difference potential (whose amplitudes were temporally overlapping with the N1) and a P3 component. N1/MMN and P3 amplitudes were significantly more pronounced for deviants as compared to standards during both listening conditions. Active listening augmented P3 modulation to deviants significantly compared to passive listening, whereas deviance detection as indexed by N1/MMN modulation was unaffected by the task. During passive listening, sLORETA contrasts (deviants > standards) revealed significant activations in the right superior temporal gyrus (STG) and the lingual gyri bilaterally (N1/MMN) as well as in the left and right insulae (P3). During active listening, significant activations were found for the N1/MMN in the right inferior parietal lobule (IPL) and for the P3 in multiple cortical regions (e.g., precuneus). The results provide evidence for the hypothesis that passive as well as active deviance and target detection elicit cortical activations in spatially distributed brain regions and neural networks including the ventral attention network (VAN), dorsal attention network (DAN) and salience network (SN). Based on the temporal activation of the neural sources underlying ERP modulations, a neurophysiological model of passive and active deviance and target detection is proposed which can be tested in future studies.
Dual-mode microwave system to enhance early detection of cancer
NASA Technical Reports Server (NTRS)
Carr, K. L.; El-Mahdi, A. M.; Shaeffer, J.
1981-01-01
A dual-mode microwave system has been developed that will permit early detection of cancer. The system combines the use of the passive microwave radiometer with an active transmitter. The active transmitter will provide localized heating to enhance early detection by taking advantage of the differential heating (i.e., tumor temperature with respect to surrounding tissue) associated with the thermal characteristics of tumors.
Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis.
Rasooly, Reuven; Prickril, Ben; Bruck, Hugh A; Rasooly, Avraham
2017-01-01
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.
[Methods of hygromycin B phosphotransferase activity assay in transgenic plant].
Zhuo, Qin; Yang, Xiaoguang
2004-07-01
Hygromycin B phosphotransferase (HPT) is a widely used selectable marker protein of transgenic plant. Detection of its activity is critical to studies on the development of various transgenic plants, silence of inserted gene, marker-free system development and safety assessment of transgenic food. In this paper, several methods for detecting the activity of this enzyme were reviewed.
ERIC Educational Resources Information Center
Yang, Manshu; Chow, Sy-Miin
2010-01-01
Facial electromyography (EMG) is a useful physiological measure for detecting subtle affective changes in real time. A time series of EMG data contains bursts of electrical activity that increase in magnitude when the pertinent facial muscles are activated. Whereas previous methods for detecting EMG activation are often based on deterministic or…
Detection of cardiac activity changes from human speech
NASA Astrophysics Data System (ADS)
Tovarek, Jaromir; Partila, Pavol; Voznak, Miroslav; Mikulec, Martin; Mehic, Miralem
2015-05-01
Impact of changes in blood pressure and pulse from human speech is disclosed in this article. The symptoms of increased physical activity are pulse, systolic and diastolic pressure. There are many methods of measuring and indicating these parameters. The measurements must be carried out using devices which are not used in everyday life. In most cases, the measurement of blood pressure and pulse following health problems or other adverse feelings. Nowadays, research teams are trying to design and implement modern methods in ordinary human activities. The main objective of the proposal is to reduce the delay between detecting the adverse pressure and to the mentioned warning signs and feelings. Common and frequent activity of man is speaking, while it is known that the function of the vocal tract can be affected by the change in heart activity. Therefore, it can be a useful parameter for detecting physiological changes. A method for detecting human physiological changes by speech processing and artificial neural network classification is described in this article. The pulse and blood pressure changes was induced by physical exercises in this experiment. The set of measured subjects was formed by ten healthy volunteers of both sexes. None of the subjects was a professional athlete. The process of the experiment was divided into phases before, during and after physical training. Pulse, systolic, diastolic pressure was measured and voice activity was recorded after each of them. The results of this experiment describe a method for detecting increased cardiac activity from human speech using artificial neural network.
Rogers, Anne; Vassilev, Ivaylo; Brooks, Helen; Kennedy, Anne; Blickem, Christian
2016-02-17
Primary care professionals are presumed to play a central role in delivering long-term condition management. However the value of their contribution relative to other sources of support in the life worlds of patients has been less acknowledged. Here we explore the value of primary care professionals in people's personal communities of support for long-term condition management. A mixed methods survey with nested qualitative study designed to identify relationships and social network member's (SNM) contributions to the support work of managing a long-term condition conducted in 2010 in the North West of England. Through engagement with a concentric circles diagram three hundred participants identified 2544 network members who contributed to illness management. The results demonstrated how primary care professionals are involved relative to others in ongoing self-care management. Primary care professionals constituted 15.5 % of overall network members involved in chronic illness work. Their contribution was identified as being related to illness specific work providing less in terms of emotional work than close family members or pets and little to everyday work. The qualitative accounts suggested that primary care professionals are valued mainly for access to medication and nurses for informational and monitoring activities. Overall primary care is perceived as providing less input in terms of extended self-management support than the current literature on policy and practice suggests. Thus primary care professionals can be described as providing 'minimally provided support'. This sense of a 'minimally' provided input reinforces limited expectations and value about what primary care professionals can provide in terms of support for long-term condition management. Primary care was perceived as having an essential but limited role in making a contribution to support work for long-term conditions. This coalesces with evidence of a restricted capacity of primary care to take on the work load of self-management support work. There is a need to prioritise exploring the means by which extended self-care support could be enhanced out-with primary care. Central to this is building a system capable of engaging network capacity to mobilise resources for self-management support from open settings and the broader community.
Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners.
Schmidtlein, C Ross; Kirov, Assen S; Nehmeh, Sadek A; Erdi, Yusuf E; Humm, John L; Amols, Howard I; Bidaut, Luc M; Ganin, Alex; Stearns, Charles W; McDaniel, David L; Hamacher, Klaus A
2006-01-01
The recently developed GATE (GEANT4 application for tomographic emission) Monte Carlo package, designed to simulate positron emission tomography (PET) and single photon emission computed tomography (SPECT) scanners, provides the ability to model and account for the effects of photon noncollinearity, off-axis detector penetration, detector size and response, positron range, photon scatter, and patient motion on the resolution and quality of PET images. The objective of this study is to validate a model within GATE of the General Electric (GE) Advance/Discovery Light Speed (LS) PET scanner. Our three-dimensional PET simulation model of the scanner consists of 12 096 detectors grouped into blocks, which are grouped into modules as per the vendor's specifications. The GATE results are compared to experimental data obtained in accordance with the National Electrical Manufactures Association/Society of Nuclear Medicine (NEMA/SNM), NEMA NU 2-1994, and NEMA NU 2-2001 protocols. The respective phantoms are also accurately modeled thus allowing us to simulate the sensitivity, scatter fraction, count rate performance, and spatial resolution. In-house software was developed to produce and analyze sinograms from the simulated data. With our model of the GE Advance/Discovery LS PET scanner, the ratio of the sensitivities with sources radially offset 0 and 10 cm from the scanner's main axis are reproduced to within 1% of measurements. Similarly, the simulated scatter fraction for the NEMA NU 2-2001 phantom agrees to within less than 3% of measured values (the measured scatter fractions are 44.8% and 40.9 +/- 1.4% and the simulated scatter fraction is 43.5 +/- 0.3%). The simulated count rate curves were made to match the experimental curves by using deadtimes as fit parameters. This resulted in deadtime values of 625 and 332 ns at the Block and Coincidence levels, respectively. The experimental peak true count rate of 139.0 kcps and the peak activity concentration of 21.5 kBq/cc were matched by the simulated results to within 0.5% and 0.1% respectively. The simulated count rate curves also resulted in a peak NECR of 35.2 kcps at 10.8 kBq/cc compared to 37.6 kcps at 10.0 kBq/cc from averaged experimental values. The spatial resolution of the simulated scanner matched the experimental results to within 0.2 mm.
A visual model for object detection based on active contours and level-set method.
Satoh, Shunji
2006-09-01
A visual model for object detection is proposed. In order to make the detection ability comparable with existing technical methods for object detection, an evolution equation of neurons in the model is derived from the computational principle of active contours. The hierarchical structure of the model emerges naturally from the evolution equation. One drawback involved with initial values of active contours is alleviated by introducing and formulating convexity, which is a visual property. Numerical experiments show that the proposed model detects objects with complex topologies and that it is tolerant of noise. A visual attention model is introduced into the proposed model. Other simulations show that the visual properties of the model are consistent with the results of psychological experiments that disclose the relation between figure-ground reversal and visual attention. We also demonstrate that the model tends to perceive smaller regions as figures, which is a characteristic observed in human visual perception.
Kallemeijn, Wouter W; Scheij, Saskia; Voorn-Brouwer, Tineke M; Witte, Martin D; Verhoek, Marri; Overkleeft, Hermen S; Boot, Rolf G; Aerts, Johannes M F G
2016-09-15
β-Glucoside-configured cyclophellitols are activity-based probes (ABPs) that allow sensitive detection of β-glucosidases. Their applicability to detect proteins fused with β-glucosidase was investigated in the cellular context. The tag was Rhodococcus sp. M-777 endoglycoceramidase II (EGCaseII), based on its lack of glycans and ability to hydrolyze fluorogenic 4-methylumbelliferyl β-d-lactoside (an activity absent in mammalian cells). Specific dual detection of fusion proteins was possible in vitro and in situ by using fluorescent ABPs and a fluorogenic substrate. Pre-blocking with conduritol β-epoxide (a poor inhibitor of EGCaseII) eliminated ABP labeling of endogenous β-glucosidases. ABPs equipped with biotin allowed convenient purification of the fusion proteins. Diversification of ABPs (distinct fluorophores, fluorogenic high-resolution detection moieties) should assist further research in living cells and organisms. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Greater sensitivity of the cortical face processing system to perceptually-equated face detection
Maher, S.; Ekstrom, T.; Tong, Y.; Nickerson, L.D.; Frederick, B.; Chen, Y.
2015-01-01
Face detection, the perceptual capacity to identify a visual stimulus as a face before probing deeper into specific attributes (such as its identity or emotion), is essential for social functioning. Despite the importance of this functional capacity, face detection and its underlying brain mechanisms are not well understood. This study evaluated the roles that the cortical face processing system, which is identified largely through studying other aspects of face perception, play in face detection. Specifically, we used functional magnetic resonance imaging (fMRI) to examine the activations of the fusifom face area (FFA), occipital face area (OFA) and superior temporal sulcus (STS) when face detection was isolated from other aspects of face perception and when face detection was perceptually-equated across individual human participants (n=20). During face detection, FFA and OFA were significantly activated, even for stimuli presented at perceptual-threshold levels, whereas STS was not. During tree detection, however, FFA and OFA were responsive only for highly salient (i.e., high contrast) stimuli. Moreover, activation of FFA during face detection predicted a significant portion of the perceptual performance levels that were determined psychophysically for each participant. This pattern of result indicates that FFA and OFA have a greater sensitivity to face detection signals and selectively support the initial process of face vs. non-face object perception. PMID:26592952
Wu, Yushu; Yan, Ping; Xu, Xiaowen; Jiang, Wei
2016-03-07
Uracil-DNA glycosylase (UDG) and endonuclease IV (Endo IV) play cooperative roles in uracil base-excision repair (UBER) and inactivity of either will interrupt the UBER to cause disease. Detection of UDG and Endo IV activities is crucial to evaluate the UBER process in fundamental research and diagnostic application. Here, a unique dual recognition hairpin probe mediated fluorescence amplification method was developed for sensitively and selectively detecting UDG and Endo IV activities. For detecting UDG activity, the uracil base in the probe was excised by the target enzyme to generate an apurinic/apyrimidinic (AP) site, achieving the UDG recognition. Then, the AP site was cleaved by a tool enzyme Endo IV, releasing a primer to trigger rolling circle amplification (RCA) reaction. Finally, the RCA reaction produced numerous repeated G-quadruplex sequences, which interacted with N-methyl-mesoporphyrin IX to generate an enhanced fluorescence signal. Alternatively, for detecting Endo IV activity, the uracil base in the probe was first converted into an AP site by a tool enzyme UDG. Next, the AP site was cleaved by the target enzyme, achieving the Endo IV recognition. The signal was then generated and amplified in the same way as those in the UDG activity assay. The detection limits were as low as 0.00017 U mL(-1) for UDG and 0.11 U mL(-1) for Endo IV, respectively. Moreover, UDG and Endo IV can be well distinguished from their analogs. This method is beneficial for properly evaluating the UBER process in function studies and disease prognoses.
Inhibition of calpain on oxygen glucose deprivation-induced RGC-5 necroptosis.
Chen, Shuang; Yan, Jie; Deng, Hai-Xiao; Long, Ling-Ling; Hu, Yong-Jun; Wang, Mi; Shang, Lei; Chen, Dan; Huang, Ju-Fang; Xiong, Kun
2016-10-01
The purpose of this study was to investigate the effect of inhibition of calpain on retinal ganglion cell-5 (RGC-5) necroptosis following oxygen glucose deprivation (OGD). RGC-5 cells were cultured in Dulbecco's-modified essential medium and necroptosis was induced by 8-h OGD. PI staining and flow cytometry were performed to detect RGC-5 necrosis. The calpain expression was detected by Western blotting and immunofluorescence staining. The calpain activity was tested by activity detection kit. Flow cytometry was used to detect the effect of calpain on RGC-5 necroptosis following OGD with or without N-acetyl-leucyl-leucyl-norleucinal (ALLN) pre-treatment. Western blot was used to detect the protein level of truncated apoptosis inducing factor (tAIF) in RGC-5 cells following OGD. The results showed that there was an up-regulation of the calpain expression and activity following OGD. Upon adding ALLN, the calpain activity was inhibited and tAIF was reduced following OGD along with the decreased number of RGC-5 necroptosis. In conclusion, calpain was involved in OGD-induced RGC-5 necroptosis with the increased expression of its downstream molecule tAIF.
Biasetti, Jacopo; Sampath, Kaushik; Cortez, Angel; Azhir, Alaleh; Gilad, Assaf A; Kickler, Thomas S; Obser, Tobias; Ruggeri, Zaverio M; Katz, Joseph
2017-01-01
Tracking cells and proteins' phenotypic changes in deep suspensions is critical for the direct imaging of blood-related phenomena in in vitro replica of cardiovascular systems and blood-handling devices. This paper introduces fluorescence imaging techniques for space and time resolved detection of platelet activation, von Willebrand factor (VWF) conformational changes, and VWF-platelet interaction in deep suspensions. Labeled VWF, platelets, and VWF-platelet strands are suspended in deep cuvettes, illuminated, and imaged with a high-sensitivity EM-CCD camera, allowing detection using an exposure time of 1 ms. In-house postprocessing algorithms identify and track the moving signals. Recombinant VWF-eGFP (rVWF-eGFP) and VWF labeled with an FITC-conjugated polyclonal antibody are employed. Anti-P-Selectin FITC-conjugated antibodies and the calcium-sensitive probe Indo-1 are used to detect activated platelets. A positive correlation between the mean number of platelets detected per image and the percentage of activated platelets determined through flow cytometry is obtained, validating the technique. An increase in the number of rVWF-eGFP signals upon exposure to shear stress demonstrates the technique's ability to detect breakup of self-aggregates. VWF globular and unfolded conformations and self-aggregation are also observed. The ability to track the size and shape of VWF-platelet strands in space and time provides means to detect pro- and antithrombotic processes.
NASA Astrophysics Data System (ADS)
Prochazka, Ivan; Kodet, Jan; Eckl, Johann; Blazej, Josef
2017-10-01
We are reporting on the design, construction, and performance of a photon counting detector system, which is based on single photon avalanche diode detector technology. This photon counting device has been optimized for very high timing resolution and stability of its detection delay. The foreseen application of this detector is laser ranging of space objects, laser time transfer ground to space and fundamental metrology. The single photon avalanche diode structure, manufactured on silicon using K14 technology, is used as a sensor. The active area of the sensor is circular with 200 μm diameter. Its photon detection probability exceeds 40% in the wavelength range spanning from 500 to 800 nm. The sensor is operated in active quenching and gating mode. A new control circuit was optimized to maintain high timing resolution and detection delay stability. In connection to this circuit, timing resolution of the detector is reaching 20 ps FWHM. In addition, the temperature change of the detection delay is as low as 70 fs/K. As a result, the detection delay stability of the device is exceptional: expressed in the form of time deviation, detection delay stability of better than 60 fs has been achieved. Considering the large active area aperture of the detector, this is, to our knowledge, the best timing performance reported for a solid state photon counting detector so far.
Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
Pauly, Diana; Worbs, Sylvia; Kirchner, Sebastian; Shatohina, Olena; Dorner, Martin B.; Dorner, Brigitte G.
2012-01-01
Background In the context of a potential bioterrorist attack sensitive and fast detection of functionally active toxins such as ricin from complex matrices is necessary to be able to start timely countermeasures. One of the functional detection methods currently available for ricin is the endpoint cytotoxicity assay, which suffers from a number of technical deficits. Methodology/Findings This work describes a novel online cytotoxicity assay for the detection of active ricin and Ricinus communis agglutinin, that is based on a real-time cell electronic sensing system and impedance measurement. Characteristic growth parameters of Vero cells were monitored online and used as standardized viability control. Upon incubation with toxin the cell status and the cytotoxic effect were visualized using a characteristic cell index–time profile. For ricin, tested in concentrations of 0.06 ng/mL or above, a concentration-dependent decrease of cell index correlating with cytotoxicity was recorded between 3.5 h and 60 h. For ricin, sensitive detection was determined after 24 h, with an IC50 of 0.4 ng/mL (for agglutinin, an IC50 of 30 ng/mL was observed). Using functionally blocking antibodies, the specificity for ricin and agglutinin was shown. For detection from complex matrices, ricin was spiked into several food matrices, and an IC50 ranging from 5.6 to 200 ng/mL was observed. Additionally, the assay proved to be useful in detecting active ricin in environmental sample materials, as shown for organic fertilizer containing R. communis material. Conclusions/Significance The cell-electrode impedance measurement provides a sensitive online detection method for biologically active cytotoxins such as ricin. As the cell status is monitored online, the assay can be standardized more efficiently than previous approaches based on endpoint measurement. More importantly, the real-time cytotoxicity assay provides a fast and easy tool to detect active ricin in complex sample matrices. PMID:22532852
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sang-yoon; Browne, Michael C; Rael, Carlos D
2010-01-01
In early 2009, preliminary excavation work has begun in preparation for the construction of the New Safe Confinement (NSC) at the Chernobyl Nuclear Power Plant (ChNPP) in Ukraine. The NSC is the structure that will replace the present containment structure and will confine the radioactive remains of the ChNPP Unit-4 reactor for the next 100 years. It is expected that special nuclear material (SNM) that was ejected from the Unit-4 reactor during the accident in 1986 could be uncovered and would therefore need to be safeguarded. ChNPP requested the assistance of the United States Department of Energy/National Nuclear Security Administrationmore » (NNSA) with developing a new non-destructive assay (NDA) system that is capable of assaying radioactive debris stored in 55-gallon drums. The design of the system has to be tailored to the unique circumstances and work processes at the NSC construction site and the ChNPP. This paper describes the Chernobyl Drum Assay System (CDAS), the solution devised by Los Alamos National Laboratory, Sonalysts Inc., and the ChNPP, under NNSA's International Safeguards and Engagement Program (INSEP). The neutron counter measures the spontaneous fission neutrons from the {sup 238}U, {sup 240}Pu, {sup 244}Cm in a waste drum and estimates the mass contents of the SNMs in the drum by using of isotopic compositions determined by fuel burnup. The preliminary evaluation on overall measurement uncertainty shows that the system meets design performance requirements imposed by the facility.« less
Unconventional Staging Package Selection Leads to Cost Savings
DOE Office of Scientific and Technical Information (OSTI.GOV)
,
2012-06-07
In late 2010, U.S. Department of Energy (DOE) Deputy Secretary of Energy, Daniel Poneman, directed that an analysis be conducted on the U-233 steel-clad, Zero Power Reactor (ZPR) fuel plates that were stored at Oak Ridge National Laboratory (ORNL), focusing on cost savings and any potential DOE programmatic needs for the special nuclear material (SNM). The NA-162 Nuclear Criticality Safety Program requested retention of these fuel plates for use in experiments at the Nevada National Security Site (NNSS). A Secretarial Initiative challenged ORNL to make the first shipment to the NNSS by the end of the 2011 calendar year, andmore » this effort became known as the U-233 Project Accelerated Shipping Campaign. To meet the Secretarial Initiative, National Security Technologies, LLC (NSTec), the NNSS Management and Operations contractor, was asked to facilitate the receipt and staging of the U-233 fuel plates in the Device Assembly Facility (DAF). Because there were insufficient staging containers available for the fuel plates, NSTec conducted an analysis of alternatives. The project required a staging method that would reduce the staging footprint while addressing nuclear criticality safety and radiation exposure concerns. To accommodate an intermediate staging method of approximately five years, the NSTec project team determined that a unique and unconventional staging package, the AT-400R, was available to meet the project requirements. By using the AT-400R containers, NSTec was able to realize a cost savings of approximately $10K per container, a total cost savings of nearly $450K.« less
Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi; Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki; Noda, Mamoru; Igimi, Shizunobu; Ikebukuro, Kazunori
2013-11-01
An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268-luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF-luciferase fusion protein. By means of the automatic analyzer with ZF-luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0×10 to 1.0×10(6) copies. Copyright © 2013 Elsevier B.V. All rights reserved.
Inertial navigation sensor integrated obstacle detection system
NASA Technical Reports Server (NTRS)
Bhanu, Bir (Inventor); Roberts, Barry A. (Inventor)
1992-01-01
A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.
Method for chromium analysis and speciation
Aiken, Abigail M.; Peyton, Brent M.; Apel, William A.; Petersen, James N.
2004-11-02
A method of detecting a metal in a sample comprising a plurality of metal is disclosed. The method comprises providing the sample comprising a metal to be detected. The sample is added to a reagent solution comprising an enzyme and a substrate, where the enzyme is inhibited by the metal to be detected. An array of chelating agents is used to eliminate the inhibitory effects of additional metals in the sample. An enzymatic activity in the sample is determined and compared to an enzymatic activity in a control solution to detect the metal to be detected. A method of determining a concentration of the metal in the sample is also disclosed. A method of detecting a valence state of a metal is also disclosed.
Broadband standoff detection of large molecules by mid-infrared active coherent laser spectrometry.
Macleod, Neil A; Molero, Francisco; Weidmann, Damien
2015-01-26
A widely tunable active coherent laser spectrometer (ACLaS) has been demonstrated for standoff detection of broadband absorbers in the 1280 to 1318 cm-1 spectral region using an external cavity quantum cascade laser as a mid-infrared source. The broad tuning range allows detection and quantification of vapor phase molecules, such as dichloroethane, ethylene glycol dinitrate, and tetrafluoroethane. The level of confidence in molecular mixing ratios retrieved from interfering spectral measurements is assessed in a quantitative manner. A first qualitative demonstration of condensed phase chemical detection on nitroacetanilide has also been conducted. Detection performances of the broadband ACLaS have been placed in the context of explosive detection and compared to that obtained using distributed feedback quantum cascade lasers.
A microcomputer-based daily living activity recording system.
Matsuoka, Shingo; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Thayer, Julian F; Caldwell, W Morton
2003-01-01
A new daily living activity recording system has been developed for monitoring health conditions and living patterns, such as respiration, posture, activity/rest ratios and general activity level. The system employs a piezoelectric sensor, a dual axis accelerometer, two low-power active filters, a low-power 8-bit single chip microcomputer and a 128 MB compact flash memory. The piezoelectric sensor, whose electrical polarization voltage is produced by mechanical strain, detects body movements. Its high-frequency output components reflect body movements produced by walking and running activities, while the low frequency components are mainly respiratory. The dual axis accelerometer detects, from body X and Y tilt angles, whether the patient is standing, sitting or lying down (prone, supine, left side or right side). The detected respiratory, behavior and posture signals are stored by the compact flash memory. After recording, these data are downloaded to a desktop computer and analyzed.
Seismic array observations for monitoring phreatic eruptions in Iwojima Island, Japan
NASA Astrophysics Data System (ADS)
Ueda, H.; Kawaguchi, R.; Chiba, K.; Fujita, E.; Tanada, T.
2015-12-01
Iwojima is an active volcanic island located within a 10 km wide submarine caldera about 1250 km to the south of Tokyo, Japan. The volcanic activity is characterized by intensive earthquake activity associated with an island-wide uplift with high uplift rate (30~40 cm/year) and hydrothermal activity. In the last 10 years, phreatic eruptions took place in and near the island in 2012, 2013, and 2015. In such restless volcano, predictions and detections of occurrence points of phreatic eruptions are important for ensuring safety of residents. In the previous studies, we found that the earthquake activity of Iwojima highly correlates with the island wide large uplift, but the precursory activity of the phreatic eruption in 2012 was deviated from the correlation (Ueda et al. 2013 AGU Fall Meeting). For prediction of occurrence points of phreatic eruptions and investigation of the eruption mechanism, we began observation by seismic arrays at two areas in December 2014. The seismic arrays enable to locate epicenters of volcanic tremors, which are not well located by existing seismic stations. In May and June 2015, Japan Maritime Self-Defense Force stayed in Iwojima and a live camera of Japan Meteorological Agency found very small phreatic eruptions occurred at the northern beach. Existing seismic stations could not detect seismic signals related with the eruptions. The seismic array could detect weak seismic signals related with the eruptions. Although the seismic arrays could not detect precursory signals because of too small eruption, we expect the seismic arrays can detect precursory seismic signals suggesting occurrence points of small or medium-sized phreatic eruptions. The seismic arrays also detected epicenters of harmonic and monotonic tremors took place at an active fumarolic field in the north earthen part of Iwojima. The apparent velocity of seismic waves (~1km/s) strongly suggests that the tremors relate with hydrothermal activity near ground surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna
2012-10-15
Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to scoremore » the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.« less
How Accurately Can Your Wrist Device Recognize Daily Activities and Detect Falls?
Gjoreski, Martin; Gjoreski, Hristijan; Luštrek, Mitja; Gams, Matjaž
2016-01-01
Although wearable accelerometers can successfully recognize activities and detect falls, their adoption in real life is low because users do not want to wear additional devices. A possible solution is an accelerometer inside a wrist device/smartwatch. However, wrist placement might perform poorly in terms of accuracy due to frequent random movements of the hand. In this paper we perform a thorough, large-scale evaluation of methods for activity recognition and fall detection on four datasets. On the first two we showed that the left wrist performs better compared to the dominant right one, and also better compared to the elbow and the chest, but worse compared to the ankle, knee and belt. On the third (Opportunity) dataset, our method outperformed the related work, indicating that our feature-preprocessing creates better input data. And finally, on a real-life unlabeled dataset the recognized activities captured the subject’s daily rhythm and activities. Our fall-detection method detected all of the fast falls and minimized the false positives, achieving 85% accuracy on the first dataset. Because the other datasets did not contain fall events, only false positives were evaluated, resulting in 9 for the second, 1 for the third and 15 for the real-life dataset (57 days data). PMID:27258282
Jahanian, Hesamoddin; Soltanian-Zadeh, Hamid; Hossein-Zadeh, Gholam-Ali
2005-09-01
To present novel feature spaces, based on multiscale decompositions obtained by scalar wavelet and multiwavelet transforms, to remedy problems associated with high dimension of functional magnetic resonance imaging (fMRI) time series (when they are used directly in clustering algorithms) and their poor signal-to-noise ratio (SNR) that limits accurate classification of fMRI time series according to their activation contents. Using randomization, the proposed method finds wavelet/multiwavelet coefficients that represent the activation content of fMRI time series and combines them to define new feature spaces. Using simulated and experimental fMRI data sets, the proposed feature spaces are compared to the cross-correlation (CC) feature space and their performances are evaluated. In these studies, the false positive detection rate is controlled using randomization. To compare different methods, several points of the receiver operating characteristics (ROC) curves, using simulated data, are estimated and compared. The proposed features suppress the effects of confounding signals and improve activation detection sensitivity. Experimental results show improved sensitivity and robustness of the proposed method compared to the conventional CC analysis. More accurate and sensitive activation detection can be achieved using the proposed feature spaces compared to CC feature space. Multiwavelet features show superior detection sensitivity compared to the scalar wavelet features. (c) 2005 Wiley-Liss, Inc.
Testing the Wildlink activity-detection system on wolves and white-tailed deer
Kunkel, K.E.; Chapman, R.C.; Mech, L.D.; Gese, E.M.
1991-01-01
We tested the reliability and predictive capabilities of the activity meter in the new Wildlink Data Acquisition and Recapture System by comparing activity counts with concurrent observations of captive wolf (Canis lupus) and free-ranging white-tailed deer (Odocoileus virginianus) activity. The Wildlink system stores activity data in a computer within a radio collar with which a biologist can communicate. Three levels of activity could be detected. The Wildlink system provided greater activity discrimination and was more reliable, adaptable, and efficient and was easier to use than conventional telemetry activity systems. The Wildlink system could be highly useful for determining wildlife energy budgets.