  1. X-ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Porter, F. Scott

    2004-01-01

    The X-ray Spectrometer (XRS) instrument is a revolutionary non-dispersive spectrometer that will form the basis for the Astro-E2 observatory to be launched in 2005. We have recently installed a flight spare X R S microcalorimeter spectrometer at the EBIT-I facility at LLNL replacing the XRS from the earlier Astro-E mission and providing twice the resolution. The X R S microcalorimeter is an x-ray detector that senses the heat deposited by the incident photon. It achieves a high energy resolution by operating at 0.06K and by carefully controlling the heat capacity and thermal conductance. The XRS/EBIT instrument has 32 pixels in a square geometry and achieves an energy resolution of 6 eV at 6 keV, with a bandpass from 0.1 to 12 keV (or more at higher operating temperature). The instrument allows detailed studies of the x-ray line emission of laboratory plasmas. The XRS/EBIT also provides an extensive calibration "library" for the Astro-E2 observatory.

  2. Imaging X-ray spectrometer

    NASA Technical Reports Server (NTRS)

    Grant, P. A.; Jackson, J. W., Jr.; Alcorn, G. E.; Marshall, F. E. (Inventor)

    1984-01-01

    An X-ray spectrometer for providing imaging and energy resolution of an X-ray source is described. This spectrometer is comprised of a thick silicon wafer having an embedded matrix or grid of aluminum completely through the wafer fabricated, for example, by thermal migration. The aluminum matrix defines the walls of a rectangular array of silicon X-ray detector cells or pixels. A thermally diffused aluminum electrode is also formed centrally through each of the silicon cells with biasing means being connected to the aluminum cell walls and causes lateral charge carrier depletion between the cell walls so that incident X-ray energy causes a photoelectric reaction within the silicon producing collectible charge carriers in the form of electrons which are collected and used for imaging.

  3. Alpha proton x ray spectrometer

    NASA Technical Reports Server (NTRS)

    Rieder, Rudi; Waeke, H.; Economou, T.

    1994-01-01

    Mars Pathfinder will carry an alpha-proton x ray spectrometer (APX) for the determination of the elemental chemical composition of Martian rocks and soils. The instrument will measure the concentration of all major and some minor elements, including C, N, and O at levels above typically 1 percent.

  4. Future lunar mission Active X-ray Spectrometer development: Surface roughness and geometry studies

    NASA Astrophysics Data System (ADS)

    Naito, M.; Hasebe, N.; Kusano, H.; Nagaoka, H.; Kuwako, M.; Oyama, Y.; Shibamura, E.; Amano, Y.; Ohta, T.; Kim, K. J.; Lopes, J. A. M.

    2015-07-01

    The Active X-ray Spectrometer (AXS) is considered as one of the scientific payload candidates for a future Japanese mission, SELENE-2. The AXS consists of pyroelectric X-ray generators and a Silicon Drift Detector to conduct X-Ray Fluorescence spectroscopy (XRF) on the Moon to measure major elements: Mg, Al, Si, Ca, Ti, and Fe; minor elements: Na, K, P, S, Cr and Mn; and the trace element Ni depending on their concentration. Some factors such as roughness, grain size and porosity of sample, and the geometry of X-ray incidence, emission and energy will affect the XRF measurements precision. Basic studies on the XRF are required to develop the AXS. In this study, fused samples were used to make homogeneous samples free from the effect of grain size and porosity. Experimental and numerical studies on the XRF were conducted to evaluate the effects from incidence and emission angles and surface roughness. Angle geometry and surface roughness will be optimized for the design of the AXS on future missions from the results of the experiment and the numerical simulation.

  5. CHANG'E-3 Active Particle-induced X-ray Spectrometer: The synthesis design and performance

    NASA Astrophysics Data System (ADS)

    Cui, XingZhu; Peng, Wenxi; Wang, Huanyu; Liang, XiaoHua

    the Active Particle X-ray Spectrometer (APXS) was designed to deduce the elemental abundances of samples on the moon. Similar to the Alpha Particle X-ray Spectrometers onboard MSL and MER , the APXS was also an instrument took the advantage of X-ray fluorescence mechanism to determine elemental abundances, it determines the chemical compositions of both soil and rocks along the traverse of the rover. To provide a sound instrument working on the lunar surface,Four components were integrated in the APXS, the performances of the components were described in this paper.

  6. Atmospheric electron x-ray spectrometer

    NASA Technical Reports Server (NTRS)

    Feldman, Jason E. (Inventor); George, Thomas (Inventor); Wilcox, Jaroslava Z. (Inventor)

    2002-01-01

    The present invention comprises an apparatus for performing in-situ elemental analyses of surfaces. The invention comprises an atmospheric electron x-ray spectrometer with an electron column which generates, accelerates, and focuses electrons in a column which is isolated from ambient pressure by a:thin, electron transparent membrane. After passing through the membrane, the electrons impinge on the sample in atmosphere to generate characteristic x-rays. An x-ray detector, shaping amplifier, and multi-channel analyzer are used for x-ray detection and signal analysis. By comparing the resultant data to known x-ray spectral signatures, the elemental composition of the surface can be determined.

  7. STS-54 Diffuse X-Ray Spectrometer

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Louis Kaluzienski, Program Scientist, Wilton T. Sanders, Principal Investigator, and Chris Dunker, Diffuse X-Ray Spectrometer (DXS) Mission Manager, each give an overview of the DXS, including the purpose of the DXS, a brief description of x-ray astronomy, the scientific objectives of the DXS, and information on the STS-54 Endeavour mission, in which the DXS is part of the payload. The men then answer questions from the press.

  8. X-ray emitting hot plasma in solar active regions observed by the SphinX spectrometer

    NASA Astrophysics Data System (ADS)

    Miceli, M.; Reale, F.; Gburek, S.; Terzo, S.; Barbera, M.; Collura, A.; Sylwester, J.; Kowalinski, M.; Podgorski, P.; Gryciuk, M.

    2012-08-01

    Aims: The detection of very hot plasma in the quiescent corona is important for diagnosing heating mechanisms. The presence and the amount of such hot plasma is currently debated. The SphinX instrument on-board the CORONAS-PHOTON mission is sensitive to X-ray emission of energies well above 1 keV and provides the opportunity to detect the hot plasma component. Methods: We analysed the X-ray spectra of the solar corona collected by the SphinX spectrometer in May 2009 (when two active regions were present). We modelled the spectrum extracted from the whole Sun over a time window of 17 days in the 1.34-7 keV energy band by adopting the latest release of the APED database. Results: The SphinX broadband spectrum cannot be modelled by a single isothermal component of optically thin plasma and two components are necessary. In particular, the high statistical significance of the count rates and the accurate calibration of the spectrometer allowed us to detect a very hot component at ~7 million K with an emission measure of ~2.7 × 1044 cm-3. The X-ray emission from the hot plasma dominates the solar X-ray spectrum above 4 keV. We checked that this hot component is invariably present in both the high and low emission regimes, i.e. even excluding resolvable microflares. We also present and discuss the possibility of a non-thermal origin (which would be compatible with a weak contribution from thick-target bremsstrahlung) for this hard emission component. Conclusions: Our results support the nanoflare scenario and might confirm that a minor flaring activity is ever-present in the quiescent corona, as also inferred for the coronae of other stars.

  9. Electron-ion-x-ray spectrometer system

    SciTech Connect

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.; LeBrun, T.

    1993-10-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays.

  10. X-Ray Background Survey Spectrometer (XBSS)

    NASA Technical Reports Server (NTRS)

    Sanders, W. T. (Principal Investigator); Paulos, R. J.

    1996-01-01

    The objective of this investigation was to perform a spectral survey of the low energy diffuse X-ray background using the X-ray Background Survey Spectrometer (XBSS) on board the Space Station Freedom (SSF). XBSS obtains spectra of the X-ray diffuse background in the 11-24 A and 44-84 A wavelength intervals over the entire sky with 15 deg spatial resolution. These X-rays are almost certainly from a very hot (10(exp 6) K) component of the interstellar medium that is contained in regions occupying a large fraction of the interstellar volume near the Sun. Astrophysical plasmas near 10(exp 6) K are rich in emission lines, and the relative strengths of these lines, besides providing information about the physical conditions of the emitting gas, also provide information about its history and heating mechanisms.

  11. A diffuse soft X-ray spectrometer

    NASA Technical Reports Server (NTRS)

    Mccammon, D.

    1981-01-01

    A design for a diffuse X-ray spectrometer utilizing Bragg reflection is described. The geometry has a very high throughput for a given physical size and allows simultaneous observation at all wavelengths within its range. Spectral resolving power is about 35 to 50. A similar unit equipped with thallium acid pthallate crystals will cover the 11 - 24 A-range with about half this throughput and twice the resolving power.

  12. Monolithic CMOS imaging x-ray spectrometers

    NASA Astrophysics Data System (ADS)

    Kenter, Almus; Kraft, Ralph; Gauron, Thomas; Murray, Stephen S.

    2014-07-01

    The Smithsonian Astrophysical Observatory (SAO) in collaboration with SRI/Sarnoff is developing monolithic CMOS detectors optimized for x-ray astronomy. The goal of this multi-year program is to produce CMOS x-ray imaging spectrometers that are Fano noise limited over the 0.1-10keV energy band while incorporating the many benefits of CMOS technology. These benefits include: low power consumption, radiation "hardness", high levels of integration, and very high read rates. Small format test devices from a previous wafer fabrication run (2011-2012) have recently been back-thinned and tested for response below 1keV. These devices perform as expected in regards to dark current, read noise, spectral response and Quantum Efficiency (QE). We demonstrate that running these devices at rates ~> 1Mpix/second eliminates the need for cooling as shot noise from any dark current is greatly mitigated. The test devices were fabricated on 15μm, high resistivity custom (~30kΩ-cm) epitaxial silicon and have a 16 by 192 pixel format. They incorporate 16μm pitch, 6 Transistor Pinned Photo Diode (6TPPD) pixels which have ~40μV/electron sensitivity and a highly parallel analog CDS signal chain. Newer, improved, lower noise detectors have just been fabricated (October 2013). These new detectors are fabricated on 9μm epitaxial silicon and have a 1k by 1k format. They incorporate similar 16μm pitch, 6TPPD pixels but have ~ 50% higher sensitivity and much (3×) lower read noise. These new detectors have undergone preliminary testing for functionality in Front Illuminated (FI) form and are presently being prepared for back thinning and packaging. Monolithic CMOS devices such as these, would be ideal candidate detectors for the focal planes of Solar, planetary and other space-borne x-ray astronomy missions. The high through-put, low noise and excellent low energy response, provide high dynamic range and good time resolution; bright, time varying x-ray features could be temporally and

  13. Laboratory verification of the Active Particle-induced X-ray Spectrometer (APXS) on the Chang'e-3 mission

    NASA Astrophysics Data System (ADS)

    Zhang, Guang-Liang; Li, Chun-Lai; Fu, Xiao-Hui; Zhang, Li-Yan; Ban, Cao; Li, Han; Zou, Yong-Liao; Peng, Wen-Xi; Cui, Xing-Zhu; Zhang, Cheng-Mo; Wang, Huan-Yu

    2015-11-01

    In the Chang'e-3 mission, the Active Particle-induced X-ray Spectrometer (APXS) on the Yutu rover is used to analyze the chemical composition of lunar soil and rock samples. APXS data are only valid are only if the sensor head gets close to the target and integration time lasts long enough. Therefore, working distance and integration time are the dominant factors that affect APXS results. This study confirms the ability of APXS to detect elements and investigates the effects of distance and time on the measurements. We make use of a backup APXS instrument to determine the chemical composition of both powder and bulk samples under the conditions of different working distances and integration times. The results indicate that APXS can detect seven major elements, including Mg, Al, Si, K, Ca, Ti and Fe under the condition that the working distance is less than 30 mm and having an integration time of 30 min. The statistical deviation is smaller than 15%. This demonstrates the instrument's ability to detect major elements in the sample. Our measurements also indicate the increase of integration time could reduce the measurement error of peak area, which is useful for detecting the elements Mg, Al and Si. However, an increase in working distance can result in larger errors in measurement, which significantly affects the detection of the element Mg.

  14. Major Elements Abundances in Chang'E-3 Landing Site from Active Particle-induced X-ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoping; Xie, Minggang; Zhu, Meng-Hua; Dong, Wudong; Tang, Zesheng; Xu, Aoao

    2015-04-01

    Chang'E-3, China's first Moon lander and rover mission, was launched at 17:30 on 1st December 2013 (UTC) and successfully landed on Moon surface at 13:11 on 14th December 2013 (UTC). About 8 hours later after the soft landing, the rover, named "Yutu' after a mythological rabbit that lives on the Moon as a pet of the Moon goddess, was successfully separated from the lander and started its adventure on the Moon. The success of this mission marks the first soft-landing on the Moon since 1976. The landing site is in northern Mare Imbrium (N44.12, W19.51), close to the boundary of two different geologic units and sits on 'young' Eratoshenian lava flows which spread several hundreds to thousands of kilometers. The mare basalts in the landing site are believed to be formed from the lava flows ~2.5 billion years ago, which are significantly younger than all of the returned lunar samples, dating from 3.1 to 3.8 billion years ago. This makes the landing site a very interesting place for exploring geochemical characteristics of the young lava flows and lunar evolution in a later stage. Active Particle-induced X-ray Spectrometer (APXS) is the only payload on the robotic arm of Yutu rover. It was designed to measure the intensities of characteristic fluorescent X-rays produced by interactions of lunar sample with incident X-rays. Major elements abundances of Mg, Al, Si, Ca, Ti, Fe on the lunar surface were expected to be detected after the exploration. On December 24th (UTC), 2013 and January 14th (UTC), 2014, APXS performed 4 successful measurements on lunar soils along Yutu's track. Characteristic peaks of Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Sr and Zr could be clearly seen from the measured spectra. A global fit based on minimum chi-square method has been performed to disentangle different components in the measured spectra. These components include Kα and/or Kβ peaks of each element, escape peaks, exponential and shelf tail of major peaks and electronic noises, etc

  15. Development of mercuric iodide uncooled x ray detectors and spectrometers

    NASA Technical Reports Server (NTRS)

    Iwanczyk, Jan S.

    1990-01-01

    The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

  16. [The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect].

    PubMed

    Dong, Yi-fan; Fan, Rui-rui; Guo, Dong-ya; Zhang, Chun-lei; Gao, Min; Wang, Jin-zhou; Liu, Ya-qing; Zhou, Da-wei; Wang, Huan-yu

    2016-02-01

    Pyroelectric X-ray generator is implemented, and an X-ray fluorescence spectrometer is accomplished by combining the pyroelectric X-ray generator with a high energy resolution silicon drift detector. Firstly, the parameters of the X-ray generator are decided by analyzing and calculating the influence of the thickness of the pyroelectriccrystal and the thickness of the target on emitted X-ray. Secondly, the emitted X-ray is measured. The energy of emitted X-ray is from 1 to 27 keV, containing the characteristic X-ray of Cu and Ta, and the max counting rate is more than 3 000 per second. The measurement also proves that the detector of the spectrometer has a high energy resolution which the FWMH is 210 eV at 8. 05 keV. Lastly, samples of Fe, Ti, Cr and high-Ti basalt are analyzed using the spectrometer, and the results are agreed with the elements of the samples. It shows that the spectrometer consisting of a pyroelectric X-ray generator and a silicon drift detector is effective for element analysis. Additionally, because each part of the spectrometer has a small volume, it can be easily modified to a portable one which is suitable for non-destructive, on-site and quick element analysis. PMID:27209767

  17. [The X-Ray Fluorescence Spectrometer Based on Pyroelectric Effect].

    PubMed

    Dong, Yi-fan; Fan, Rui-rui; Guo, Dong-ya; Zhang, Chun-lei; Gao, Min; Wang, Jin-zhou; Liu, Ya-qing; Zhou, Da-wei; Wang, Huan-yu

    2016-02-01

    Pyroelectric X-ray generator is implemented, and an X-ray fluorescence spectrometer is accomplished by combining the pyroelectric X-ray generator with a high energy resolution silicon drift detector. Firstly, the parameters of the X-ray generator are decided by analyzing and calculating the influence of the thickness of the pyroelectriccrystal and the thickness of the target on emitted X-ray. Secondly, the emitted X-ray is measured. The energy of emitted X-ray is from 1 to 27 keV, containing the characteristic X-ray of Cu and Ta, and the max counting rate is more than 3 000 per second. The measurement also proves that the detector of the spectrometer has a high energy resolution which the FWMH is 210 eV at 8. 05 keV. Lastly, samples of Fe, Ti, Cr and high-Ti basalt are analyzed using the spectrometer, and the results are agreed with the elements of the samples. It shows that the spectrometer consisting of a pyroelectric X-ray generator and a silicon drift detector is effective for element analysis. Additionally, because each part of the spectrometer has a small volume, it can be easily modified to a portable one which is suitable for non-destructive, on-site and quick element analysis.

  18. The ITER core imaging x-ray spectrometer: x-ray calorimeter performance.

    PubMed

    Beiersdorfer, P; Brown, G V; Clementson, J; Dunn, J; Morris, K; Wang, E; Kelley, R L; Kilbourne, C A; Porter, F S; Bitter, M; Feder, R; Hill, K W; Johnson, D; Barnsley, R

    2010-10-01

    We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

  19. Soft X-ray polarimeter-spectrometer SOLPEX

    NASA Astrophysics Data System (ADS)

    Steslicki, Marek; Sylwester, Janusz; Plocieniak, Stefan; Bakala, Jaroslaw; Szaforz, Zaneta Anna; Scislowski, Daniel; Kowalinski, Miroslaw; Hernandez, Jose; Vadimovich Kuzin, Sergey; Shestov, Sergey

    2015-08-01

    We present an innovative soft X-ray polarimeter and spectrometer SOLPEX. The instrument will be mounted aboard the ISS within the Russian science complex KORTES. The measurements to be made by SOLPEX are expected to be of unprecedented quality in terms of sensitivity to detect the soft-X- ray polarization of solar emission emanating from active regions and flares in particular. Simultaneous measurements of the polarization degree and the other characteristics (eg. evolution of the spectra) constitute the last, rather unexplored area of solar X-ray spectroscopy providing substantial diagnostic potential. Second important science task to be addressed are the measurements of Doppler shifts in selected X-ray spectral emission lines formed in hot flaring sources. The novel-type Dopplerometer (flat Bragg crystal drum unit) is planned to be a part of SOLPEX and will allow to measure line Doppler shifts in absolute terms with unprecedented time resolution (fraction of a second) during the impulsive flare phases. We shall present some details of the SolpeX instrument and discuss observing sequences in a view of science objectives to be reached.

  20. Atmospheric electron-induced x-ray spectrometer development

    NASA Technical Reports Server (NTRS)

    Wilcox, Jaroslava Z.; Urgiles, Eduardo; Toda, Risaku; Crisp, Joy

    2005-01-01

    This paper extends the work reported at the IEEE Aerospace conference in 2001 and 2003 where the concept and progress in the development of the so called atmospheric Electron X-ray Spectrometer (AEXS) has been described.

  1. Method of fabricating an imaging X-ray spectrometer

    NASA Technical Reports Server (NTRS)

    Alcorn, G. E. (Inventor); Burgess, A. S. (Inventor)

    1986-01-01

    A process for fabricating an X-ray spectrometer having imaging and energy resolution of X-ray sources is discussed. The spectrometer has an array of adjoinging rectangularly shaped detector cells formed in a silicon body. The walls of the cells are created by laser drilling holes completely through the silicon body and diffusing n(+) phosphorous doping material therethrough. A thermally migrated aluminum electrode is formed centrally through each of the cells.

  2. Data processing for the Active Particle-induced X-ray Spectrometer and initial scientific results from Chang'e-3 mission

    NASA Astrophysics Data System (ADS)

    Fu, Xiao-Hui; Li, Chun-Lai; Zhang, Guang-Liang; Zou, Yong-Liao; Liu, Jian-Jun; Ren, Xin; Tan, Xu; Zhang, Xiao-Xia; Zuo, Wei; Wen, Wei-Bin; Peng, Wen-Xi; Cui, Xing-Zhu; Zhang, Cheng-Mo; Wang, Huan-Yu

    2014-12-01

    The Active Particle-induced X-ray Spectrometer (APXS) is an important payload mounted on the Yutu rover, which is part of the Chang'e-3 mission. The scientific objective of APXS is to perform in-situ analysis of the chemical composition of lunar soil and rock samples. The radioactive sources, 55Fe and 109Cd, decay and produce α-particles and X-rays. When X-rays and α-particles interact with atoms in the surface material, they knock electrons out of their orbits, which release energy by emitting X-rays that can be measured by a silicon drift detector (SDD). The elements and their concentrations can be determined by analyzing their peak energies and intensities. APXS has analyzed both the calibration target and lunar soil once during the first lunar day and again during the second lunar day. The total detection time lasted about 266 min and more than 2000 frames of data records have been acquired. APXS has three operating modes: calibration mode, distance sensing mode and detection mode. In detection mode, work distance can be calculated from the X-ray counting rate collected by SDD. Correction for the effect of temperature has been performed to convert the channel number for each spectrum to X-ray energy. Dead time correction is used to eliminate the systematic error in quantifying the activity of an X-ray pulse in a sample and derive the real count rate. We report APXS data and initial results during the first and second lunar days for the Yutu rover. In this study, we analyze the data from the calibration target and lunar soil on the first lunar day. Seven major elements, including Mg, Al, Si, K, Ca, Ti and Fe, have been identified. Comparing the peak areas and ratios of calibration basalt and lunar soil the landing site was found to be depleted in K, and have lower Mg and Al but higher Ca, Ti, and Fe. In the future, we will obtain the elemental concentrations of lunar soil at the Chang'e-3 landing site using APXS data.

  3. High intensity line source for x-ray spectrometer calibration

    SciTech Connect

    Thoe, R.S.

    1986-06-01

    A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 ..mu.. x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10/sup 4/) time-resolved cyrstal spectrometer, will be discussed in detail.

  4. X-ray imaging crystal spectrometer for extended X-ray sources

    DOEpatents

    Bitter, Manfred L.; Fraenkel, Ben; Gorman, James L.; Hill, Kenneth W.; Roquemore, A. Lane; Stodiek, Wolfgang; von Goeler, Schweickhard E.

    2001-01-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

  5. X-Ray Imaging Crystal Spectrometer for Extended X-Ray Sources

    SciTech Connect

    Bitter, Manfred L.; Fraekel, Benjamin; Gorman, James L.; Hill, Kenneth W.; Roquemore, Lane A.; Stodiek, Wolfgang; Goeler, Schweickhard von

    1999-05-01

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokamak fusion experiment to provide spatially and temporally resolved data on plasma parameters such as ion temperature, toroidal and poloidal rotation, electron temperature, impurity ion charge-state distributions, and impurity transport. The imaging properties of these spherically or toroidally curved crystals provide both spectrally and spatially resolved X-ray data from the plasma using only one small spherically or toroidally curved crystal, thus eliminating the requirement for a large array of crystal spectrometers and the need to cross-calibrate the various crystals.

  6. A short working distance multiple crystal x-ray spectrometer

    USGS Publications Warehouse

    Dickinson, B.; Seidler, G.T.; Webb, Z.W.; Bradley, J.A.; Nagle, K.P.; Heald, S.M.; Gordon, R.A.; Chou, I.-Ming

    2008-01-01

    For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed ???1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K?? x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L??2 partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary. ?? 2008 American Institute of Physics.

  7. Measuring Flash X-Ray Spectra with a Compton Spectrometer

    NASA Astrophysics Data System (ADS)

    Gehring, Amanda; Espy, Michelle; Haines, Todd; Hunter, James; King, Nick; Merrill, Frank; Sedillo, Robert; Urbaitis, Algis; Volegov, Petr

    2014-09-01

    The determination of the x-ray energy spectra of flash radiographic sources is difficult due to the short nature of the pulses (~50 ns). Recently, a Compton spectrometer has been refurbished and investigated as a potential device for conducting these measurements. The spectrometer was originally designed and characterized by Morgan et al.. The spectrometer consists of a 300 kg neodymium-iron magnet and measures spectra in the <1 MeV to 20 MeV energy range. In this apparatus, the incoming x-rays are collimated into a narrow beam before encountering a converter foil. Compton electrons are ejected and collimated so that the forward-directed electrons enter the magnetic field region of the device. The position of the electrons on the magnet focal plane is a function of their energy, allowing the x-ray spectrum to be reconstructed. Recent energy calibration measurements and the spectrum reconstruction of a Bremsstrahlung source will be presented. The determination of the x-ray energy spectra of flash radiographic sources is difficult due to the short nature of the pulses (~50 ns). Recently, a Compton spectrometer has been refurbished and investigated as a potential device for conducting these measurements. The spectrometer was originally designed and characterized by Morgan et al.. The spectrometer consists of a 300 kg neodymium-iron magnet and measures spectra in the <1 MeV to 20 MeV energy range. In this apparatus, the incoming x-rays are collimated into a narrow beam before encountering a converter foil. Compton electrons are ejected and collimated so that the forward-directed electrons enter the magnetic field region of the device. The position of the electrons on the magnet focal plane is a function of their energy, allowing the x-ray spectrum to be reconstructed. Recent energy calibration measurements and the spectrum reconstruction of a Bremsstrahlung source will be presented. LA-UR-14-23602.

  8. The NIF x-ray spectrometer calibration campaign at Omega

    SciTech Connect

    Pérez, F.; Kemp, G. E.; Barrios, M. A.; Pino, J.; Scott, H.; Ayers, S.; Chen, H.; Emig, J.; Colvin, J. D.; Fournier, K. B.; Regan, S. P.; Bedzyk, M.; Shoup, M. J.; Agliata, A.; Yaakobi, B.; Marshall, F. J.; Hamilton, R. A.; Jaquez, J.; Farrell, M.; Nikroo, A.

    2014-11-15

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the OMEGA laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2–18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  9. The NIF x-ray spectrometer calibration campaign at Omega.

    PubMed

    Pérez, F; Kemp, G E; Regan, S P; Barrios, M A; Pino, J; Scott, H; Ayers, S; Chen, H; Emig, J; Colvin, J D; Bedzyk, M; Shoup, M J; Agliata, A; Yaakobi, B; Marshall, F J; Hamilton, R A; Jaquez, J; Farrell, M; Nikroo, A; Fournier, K B

    2014-11-01

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the Omega laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2-18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations. PMID:25430189

  10. The NIF x-ray spectrometer calibration campaign at Omega.

    PubMed

    Pérez, F; Kemp, G E; Regan, S P; Barrios, M A; Pino, J; Scott, H; Ayers, S; Chen, H; Emig, J; Colvin, J D; Bedzyk, M; Shoup, M J; Agliata, A; Yaakobi, B; Marshall, F J; Hamilton, R A; Jaquez, J; Farrell, M; Nikroo, A; Fournier, K B

    2014-11-01

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the Omega laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2-18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  11. Bragg x-ray survey spectrometer for ITER

    SciTech Connect

    Varshney, S. K.; Jakhar, S.; Barnsley, R.; O'Mullane, M. G.

    2012-10-15

    Several potential impurity ions in the ITER plasmas will lead to loss of confined energy through line and continuum emission. For real time monitoring of impurities, a seven channel Bragg x-ray spectrometer (XRCS survey) is considered. This paper presents design and analysis of the spectrometer, including x-ray tracing by the Shadow-XOP code, sensitivity calculations for reference H-mode plasma and neutronics assessment. The XRCS survey performance analysis shows that the ITER measurement requirements of impurity monitoring in 10 ms integration time at the minimum levels for low-Z to high-Z impurity ions can largely be met.

  12. Bragg x-ray survey spectrometer for ITER.

    PubMed

    Varshney, S K; Barnsley, R; O'Mullane, M G; Jakhar, S

    2012-10-01

    Several potential impurity ions in the ITER plasmas will lead to loss of confined energy through line and continuum emission. For real time monitoring of impurities, a seven channel Bragg x-ray spectrometer (XRCS survey) is considered. This paper presents design and analysis of the spectrometer, including x-ray tracing by the Shadow-XOP code, sensitivity calculations for reference H-mode plasma and neutronics assessment. The XRCS survey performance analysis shows that the ITER measurement requirements of impurity monitoring in 10 ms integration time at the minimum levels for low-Z to high-Z impurity ions can largely be met.

  13. Two crystal x-ray spectrometers for OMEGA experiments

    NASA Astrophysics Data System (ADS)

    Reverdin, C.; Casner, A.; Girard, F.; Lecherbourg, L.; Loupias, B.; Tassin, V.; Philippe, F.

    2016-11-01

    Two x-ray spectrometers have been built for x-ray spectroscopy of laser-produced plasmas on OMEGA at the Laboratory for Laser Energetics (LLE) by Commissariat a ̀ l'Energie Atomique et aux énergies alternatives (CEA). The accessible photon energy range is from 1.5 to 20 keV. The first spectrometer, called X-ray CEA Crystal Spectrometer with a Charge-Injection Device (XCCS-CID), records three spectra with three crystals coupled to a time integrated CID camera. The second one, called X-ray CEA Crystal Spectrometer (XCCS) with a framing camera, is time resolved and records four spectra with two crystals on the four frames of a framing camera. Cylindrical crystals are used in Johan geometry. Each spectrometer is positioned with a ten-inch manipulator inside the OMEGA target chamber. In each experiment, after choosing a spectral window, a specific configuration is designed and concave crystals are precisely positioned on a board with angled wedges and spacers. Slits on snouts enable 1D spatial resolution to distinguish spectra emitted from different parts of the target.

  14. The Bragg solar x-ray spectrometer SolpeX

    NASA Astrophysics Data System (ADS)

    Ścisłowski, D.; Sylwester, J.; Steślicki, M.; Płocieniak, S.; Bąkała, J.; Szaforz, Ż.; Kowaliński, M.; Podgórski, P.; Trzebiński, W.; Hernandez, J.; Barylak, J.; Barylak, A.; Kuzin, Sergey

    2015-09-01

    Detection of polarization and spectra measurement of X-ray solar flare emission are indispensable in improving our understanding of the processes releasing energy of these most energetic phenomena in the solar system. We shall present some details of the construction of SolpeX - an innovative Bragg soft X-ray flare polarimeter and spectrometer. The instrument is a part of KORTES - Russian instrument complex to be mounted aboard the science module to be attached to the International Space Station (2017/2018). The SolpeX will be composed of three individual measuring units: the soft X-ray polarimeter with 1-2% linear polarization detection threshold, a fast-rotating flat crystal X-ray spectrometer with a very high time resolution (0.1 s) and a simple pinhole soft X-ray imager-spectrometer with a moderate spatial (~20 arcsec), spectral (0.5 keV) and high time resolution (0.1 s). Having a fast rotating unit to be served with power, telemetry and "intelligence" poses a challenge for the designer. Some of the solutions to this will be provided and described.

  15. The Astro-E High Resolution X-Ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Kelley, Richard L.; Audley, Michael D.; Boyce, Kevin R.; Breon, Susan R.; Fujimoto, Ryuichi; Gendreau, Keith C.; Holt, Stephen S.; Ishisaki, Yoshitaka; McCammon, Dan; Mihara, Tatehiro

    1999-01-01

    The Astro-E High Resolution X-ray Spectrometer (XRS) was developed jointly by the NASA/Goddard Space Flight Center and the Institute of Space and Astronautical Science in Japan. The instrument is based on a new approach to spectroscopy, the X-ray microcalorimeter. This device senses the energies of individual X-ray photons as heat with extreme precision. A 32 channel array of microcalorimeters is being employed, each with an energy resolution of about 12 eV at 6 keV (the Fe-K region). This will provide spectral resolving power 10 times higher than any other non-dispersive X-ray spectrometer. The instrument incorporates a three stage cooling system capable of operating the array at 60 mK for about two years in orbit. The array sits at the focus of a grazing incidence conical mirror. The quantum efficiency of the microcalorimeters and the reflectivity of the X-ray mirror system combine to give high throughput over the 0.3-12 keV energy band. This new capability will enable the study of a wide range of high-energy astrophysical sources with unprecedented spectral sensitivity. This paper presents the basic design requirements and implementation of the XRS, and also describes the instrument parameters and performance.

  16. A soft X-ray spectrometer for diffuse cosmic sources

    NASA Technical Reports Server (NTRS)

    Borken, R. J.; Kraushaar, W. L.

    1976-01-01

    The design of a Bragg crystal spectrometer for the diffuse soft X-ray background is described. The instrument has no moving parts; a 6 degree x 20 degree FWHM field of view; resolution in the range 20-100; and spans wavelength ranges 44-80 A or 13-23 A when lead stearate or KAP crystals are used. If placed on a small spacecraft, integration times of approximately 1000 s will be required to detect the existence of the stronger lines expected in the X-ray background.

  17. Comets: mechanisms of x-ray activity

    NASA Astrophysics Data System (ADS)

    Ibadov, Subhon

    2016-07-01

    Basic mechanisms of X-ray activity of comets are considered, including D-D mechanism corresponding to generation of X-rays due to production of hot short-living plasma clumps at high-velocity collisions between cometary and interplanetary dust particles as well as M-M one corresponding to production of X-rays due to recombination of multicharge ions of solar wind plasma via charge exchange process at their collisions with molecules/atoms of the cometary atmospheres. Peculiarities of the variation of the comet X-ray spectrum and X-ray luminosity with variation of its heliocentric distance are revealed.

  18. Time-resolved doubly bent crystal x-ray spectrometer

    SciTech Connect

    Hockaday, M.P.; Wilke, M.D.; Blake, R.L.; Vaninetti, J.; Gray, N.T.; Nedrow, P.T.

    1988-08-01

    X-ray spectroscopy is an essential tool in high-temperature plasma research. We describe a time-resolved x-ray spectrometer suitable for measuring spectra in harsh environments common to many very high-energy density laboratory plasma sources. The spectrometer consisted of a doubly curved Si(111) crystal diffraction element, a WL-1201 (ZnO:Ga) phosphor, a coherent fiber-optic array, and two visible streak cameras. The spectrometer design described here has a minimum time resolution of 1.3 ns with 2.8-eV spectral resolution over a 200-eV-wide bandpass in the 6--7-keV region of the spectrum. Complete system spectral throughput calibrations were done at the Cornell High Energy Synchrotron (CHESS). Details of the design and calibration results are presented.

  19. Time-resolved doubly bent crystal x-ray spectrometer

    SciTech Connect

    Hockaday, M.P.; Wilke, M.D.; Blake, R.L.; Vaninetti, J.; Gray, N.T.; Nedrow, P.T.

    1988-01-01

    X-ray spectroscopy is an essential tool in high temperature plasma research. We describe a time-resolved x-ray spectrometer suitable for measuring spectra in harsh environments common to many very high energy density laboratory plasma sources. The spectrometer consisted of a doubly curved Si(111) crystal diffraction element, a WL-1201 (ZnO:Ga) phosphor, a coherent fiber optic array, and two visible streak cameras. The spectrometer design described here has a minimum time resolution of 1.3 ns with 2.8 eV spectral resolution over a 200 eV wide bandpass in the 6-7 keV region of the spectrum. Complete system spectral throughput calibrations were done at the Cornell High Energy Synchrotron (CHESS). Details of the design and calibration results are presented. 5 refs., 5 figs.

  20. Imaging X-ray Thomson Scattering Spectrometer Design and Demonstration

    SciTech Connect

    Gamboa, E.J.; Huntington, C.M.; Trantham, M.R.; Keiter, P.A; Drake, R.P.; Montgomery, David; Benage, John F.; Letzring, Samuel A.

    2012-05-04

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally-curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  1. Time-Resolved Hard X-Ray Spectrometer

    SciTech Connect

    Kenneth Moya; Ian McKennaa; Thomas Keenana; Michael Cuneob

    2007-03-01

    Wired array studies are being conducted at the SNL Z accelerator to maximize the x-ray generation for inertial confinement fusion targets and high energy density physics experiments. An integral component of these studies is the characterization of the time-resolved spectral content of the x-rays. Due to potential spatial anisotropy in the emitted radiation, it is also critical to diagnose the time-evolved spectral content in a space-resolved manner. To accomplish these two measurement goals, we developed an x-ray spectrometer using a set of high-speed detectors (silicon PIN diodes) with a collimated field-of-view that converged on a 1-cm-diameter spot at the pinch axis. Spectral discrimination is achieved by placing high Z absorbers in front of these detectors. We built two spectrometers to permit simultaneous different angular views of the emitted radiation. Spectral data have been acquired from recent Z shots for the radial and polar views. UNSPEC1 has been adapted to analyze and unfold the measured data to reconstruct the x-ray spectrum. The unfold operator code, UFO2, is being adapted for a more comprehensive spectral unfolding treatment.

  2. Time-resolved hard x-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Moy, Kenneth; Cuneo, Michael; McKenna, Ian; Keenan, Thomas; Sanford, Thomas; Mock, Ray

    2006-08-01

    Wired array studies are being conducted at the SNL Z accelerator to maximize the x-ray generation for inertial confinement fusion targets and high energy density physics experiments. An integral component of these studies is the characterization of the time-resolved spectral content of the x-rays. Due to potential spatial anisotropy in the emitted radiation, it is also critical to diagnose the time-evolved spectral content in a space-resolved manner. To accomplish these two measurement goals, we developed an x-ray spectrometer using a set of high-speed detectors (silicon PIN diodes) with a collimated field-of-view that converged on a 1-cm-diameter spot at the pinch axis. Spectral discrimination is achieved by placing high Z absorbers in front of these detectors. We built two spectrometers to permit simultaneous different angular views of the emitted radiation. Spectral data have been acquired from recent Z shots for the radial and axial (polar) views. UNSPEC 1 has been adapted to analyze and unfold the measured data to reconstruct the x-ray spectrum. The unfold operator code, UFO2, is being adapted for a more comprehensive spectral unfolding treatment.

  3. The Soft X-Ray Spectrometer (SXS) for the ISAS/JAXA New Exploration X-Ray Telescope

    NASA Astrophysics Data System (ADS)

    Kelley, Richard L.; Kilbourne, C. A.; McCammon, D.; Mushotzky, R. F.; Okajima, T.; Petre, R.; Porter, F. S.; Serlemitsos, P. J.; Smith, R. K.; Soong, Y.; Szymkowiak, A. E.; Mitsuda, K.; Ohashi, T.; Ishisaki, Y.; Ezoe, Y.; Yamasaki, N. Y.; Shinozaki, K.; Fujimoto, R.; Kawaharada, M.

    2008-03-01

    The ISAS/JAXA New Exploration X-Ray Telescope (NEXT) is now under development for launch in 2013. The observatory is designed to provide extremely high spectral resolution with large collecting area below 10 keV using an x-ray calorimeter, and a very large band pass (up to 300 keV) with extraordinary sensitivity over the range 10-80 keV using focusing x-ray optics. In this talk we will discuss plans for the Soft X-Ray Spectrometer (SXS), which uses an x-ray calorimeter array to provide the high spectral resolution. The SXS is a joint effort between ISAS and NASA and recently proposed to NASA as a Mission of Opportunity for the US participation. The SXS incorporates a 6x6 calorimeter array that has strong heritage in the Suzaku program and better than 7 eV energy resolution, with 4-5 eV expected based on recent laboratory tests. The cryogenic system will be a hybrid design with both liquid helium and mechanical coolers to provide a robust, redundant system with long life (> 3 years). The x-ray optical system (6 m focal length) uses thin-foil conical optics to provide at least 220 square cm at 6 keV. The SXS will enable a wide variety of interesting science topics to be pursued, including testing theories of structure formation using velocity measurements of clusters of galaxies and inferring the energy output from the jets and winds of active galaxies. The SXS will accurately measure metal abundances in the oldest galaxies, providing unique information on the origin of the elements, and observe matter in extreme gravitational fields, enabling time-resolved spectra from material approaching the event horizon of a black hole. Along with providing the instrument, we have proposed a well supported guest investigator program that will enable full US participation.

  4. Elemental analysis using a handheld X-Ray fluorescence spectrometer

    USGS Publications Warehouse

    Groover, Krishangi; Izbicki, John

    2016-06-24

    The U.S. Geological Survey is collecting geologic samples from local stream channels, aquifer materials, and rock outcrops for studies of trace elements in the Mojave Desert, southern California. These samples are collected because geologic materials can release a variety of elements to the environment when exposed to water. The samples are to be analyzed with a handheld X-ray fluorescence (XRF) spectrometer to determine the concentrations of up to 27 elements, including chromium.

  5. Elemental analysis using a handheld X-Ray fluorescence spectrometer

    USGS Publications Warehouse

    Groover, Krishangi; Izbicki, John

    2016-01-01

    The U.S. Geological Survey is collecting geologic samples from local stream channels, aquifer materials, and rock outcrops for studies of trace elements in the Mojave Desert, southern California. These samples are collected because geologic materials can release a variety of elements to the environment when exposed to water. The samples are to be analyzed with a handheld X-ray fluorescence (XRF) spectrometer to determine the concentrations of up to 27 elements, including chromium.

  6. The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory

    SciTech Connect

    Kelley, R. L.; Bandler, S. R.; Kilbourne, C. A.; Porter, F. S.; Shirron, P.; Smith, S. J.; Whitehouse, P.; Ezoe, Y.; Ishisaki, Y.; Ohashi, T.; Fujimoto, R.; Sato, K.; Gottardi, L.; Hartog, R. den; Herder, J.-W. den; Hoevers, H.; Korte, P. de; Kuur, J. van der

    2009-12-16

    The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for the X-Ray Microcalorimeter Spectrometer (XMS) are a spectral resolution of 2.5 eV over the central 2'x2' in the 0.3-7.0 keV band, and 10 eV to the edge of the 5'x5' field of view (FOV). The XMS is now based on a microcalorimeter array of Transition-Edge Sensor (TES) thermometers with Au/Bi absorbers and a SQUID MUX readout. One of the concepts studied as part of the mission formulation has a core 40x40 array corresponding to a 2'x2' FOV with 3'' pixels surrounded by an outer, annular 52x52 array of 6'' pixels that extends the field of view to 5.4'x5.4' with better than 10 eV resolution. There are several options for implementing the readout and cooling system of the XMS under study in the US, Europe and Japan. The ADR system will have from two to five stages depending on the performance of the cryocooler. Mechanical coolers with sufficient cooling power at 4K are available now, and {approx}2K coolers are under development. In this paper we give an overview of the XMS instrument, and some of the tradeoffs to be addressed for this observatory instrument.

  7. Temporal Gain Correction for X-ray Calorimeter Spectrometers

    NASA Astrophysics Data System (ADS)

    Porter, F. S.; Chiao, M. P.; Eckart, M. E.; Fujimoto, R.; Ishisaki, Y.; Kelley, R. L.; Kilbourne, C. A.; Leutenegger, M. A.; McCammon, D.; Mitsuda, K.; Sawada, M.; Szymkowiak, A. E.; Takei, Y.; Tashiro, M.; Tsujimoto, M.; Watanabe, T.; Yamada, S.

    2016-07-01

    Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-H/SXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

  8. The Astro-H Soft X-ray Spectrometer (SXS)

    NASA Astrophysics Data System (ADS)

    Porter, F. Scott; Fujimoto, Ryuichi; Kelley, Richard L.; Kilbourne, Caroline A.; Mitsuda, Kazuhiasa; Ohashi, Takaya; Astro-H/SXS Collaboration

    2009-12-01

    The Soft-X-ray Spectrometer (SXS) is a high spectral resolution, cryogenic x-ray spectrometer that will fly on the Japan/U.S. Astro-H observatory in 2014. The SXS is composed of a 36 pixel, imaging, x-ray calorimeter array that will operate at 0.05 K utilizing a 2-stage adiabatic demagnetization refrigerator and a redundant pre-cooler design using both a 40 liter liquid helium tank and a 1.7 K Joule-Thomson (JT) cryocooler. Additional redundant Stirling cycle coolers provide pre-cooling for the (JT) and cool the outer thermal shields for the JT and the helium tank. The detector system, while similar to that flown on Suzaku, is composed of larger 0.81×0.81mm pixels, but has significantly better performance, currently predicted to be better than 4 eV FWHM at 6 keV with 95% quantum efficiency. This instrument is the result of a close collaboration between many institutions in the U.S. and Japan over the last 25 years. Here we will present an overview of the SXS instrument, the SXS cooling system, and recent laboratory improvements to the detector system.

  9. Detecting X-ray Emission from Cometary Atmospheres Using the Suzaku X-ray Imaging Spectrometer

    SciTech Connect

    Brown, G V; Beiersdorfer, P; Bodewits, D; Porter, F S; Ezoe, Y; Hamaguchi, K; Hanya, M; Itoh, M; Kilbourne, C A; Kohmura, T; Maeda, Y; Negoro, H; Tsuboi, Y; Tsunemi, H; Urata, Y

    2009-11-16

    The Suzaku X-ray imaging spectrometer has been used to observe the X-ray emission from comets 73P/Schwassmann-Wachmann 3C and 8P/Tuttle. Comet 73P/Schwassmann-Wachmann 3C was observed during May and June of 2006, while it was near perihelion and passed within 0.1 AU of the Earth. Comet 8P/Tuttle was observed during January of 2008 when it was at its closest approach to the Earth at 0.25 AU, and again near perihelion at a distance of 0.5 Au from Earth. In the case of comet 73P/Schwassmann Wachmann 3C, the XIS spectra show line emission from highly charged oxygen and carbon ions as well as emission from what is most likely L-shell transitions from Mg, Si, and S ions. This line emission is caused by charge exchange recombination between solar wind ions and cometary neutrals, and can be used as a diagnostic of the solar wind. Here we present some of the results of the observation of the comet 73P/Schwassmann-Wachmann 3C.

  10. Toward active x-ray telescopes

    NASA Astrophysics Data System (ADS)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Timothy W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peter; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffery J.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Rodriguez Sanmartin, Daniel; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2011-09-01

    Future x-ray observatories will require high-resolution (< 1") optics with very-large-aperture (> 25 m2) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the areal density of the grazing-incidence mirrors to about 1 kg/m2 or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve active (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, active optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom (UK) and the Generation-X (Gen-X) concept studies in the United States (US). This paper discusses relevant technological issues and summarizes progress toward active x-ray telescopes.

  11. Toward Active X-ray Telescopes II

    NASA Technical Reports Server (NTRS)

    O'Dell, Stephen L.; Aldroft, Thomas L.; Atkins, Carolyn; Button, Timothy W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peter; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Johnson-Wilke, Raegan L.; Kolodziejczak, Jeffery J.; Lillie, Charles F.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Sanmartin, Daniel Rodriguez; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan E.; Ulmer, Melville P.; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2012-01-01

    In the half century since the initial discovery of an astronomical (non-solar) x-ray source, the sensitivity for detection of cosmic x-ray sources has improved by ten orders of magnitude. Largely responsible for this dramatic progress has been the refinement of the (grazing-incidence) focusing x-ray telescope. The future of x-ray astronomy relies upon the development of x-ray telescopes with larger aperture areas (greater than 1 m2) and finer angular resolution (less than 1.). Combined with the special requirements of grazing-incidence optics, the mass and envelope constraints of space-borne telescopes render such advances technologically challenging.requiring precision fabrication, alignment, and assembly of large areas (greater than 100 m2) of lightweight (approximately 1 kg m2 areal density) mirrors. Achieving precise and stable alignment and figure control may entail active (in-space adjustable) x-ray optics. This paper discusses relevant programmatic and technological issues and summarizes progress toward active x-ray telescopes.

  12. Evidence for beamed electrons in a limb X-ray flare observed by Hard X-Ray Imaging Spectrometer (HXIS)

    NASA Technical Reports Server (NTRS)

    Haug, Eberhard; Elwert, Gerhard

    1986-01-01

    The limb flare of November 18, 1980, 14:51 UT, was investigated on the basis of X-ray images taken by the Hard X-ray Imaging Spectrometer (HXIS) and of X-ray spectra from the Hard X-Ray Burst Spectrometer (HXRBS) aboard the Solar Maximum Mission (SMM). The impulsive burst was also recorded at microwave frequencies between 2 and 20 GHz whereas no optical flare and no radio event at frequencies below 1 GHz were reported. The flare occurred directly at the SW limb of the solar disk. Taking advantage of the spatial resolution of HXIS images, the time evolution of the X-radiation originating from relatively small source regions can be studied. Using Monte Carlo computations of the energy distribution of energetic electrons traversing the solar plasma, the bremsstrahlung spectra produced by the electrons were derived.

  13. Atmospheric Electron-Induced X-Ray Spectrometer (AEXS) Development

    NASA Technical Reports Server (NTRS)

    Wilcox, Jaroslava Z.; Urgiles, Eduardo; Toda, Risaku; George, Thomas; Douglas, Susanne; Crisp, Joy

    2005-01-01

    This paper describes the progress in the development of the so-called Atmospheric Electron X-ray Spectrometer (AEXS) instrument in our laboratory at JPL. The AEXS is a novel miniature instrument concept based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in situ, in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. By using a focused electron beam, the impinging electrons on samples in the external atmosphere excite XRF spectra from the irradiated spots with high-to-medium spatial resolution. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition. The use of high- intensity electron beam results in rapid spectrum acquisition (several minutes), and consequently low energy consumption (several tens of Joules) per acquired XRF spectrum in comparison to similar portable instruments.

  14. Developing small vacuum spark as an x-ray source for calibration of an x-ray focusing crystal spectrometer

    SciTech Connect

    Ghomeishi, Mostafa; Adikan, Faisal Rafiq Mahamd; Karami, Mohammad

    2012-10-15

    A new technique of x-ray focusing crystal spectrometers' calibration is the desired result. For this purpose the spectrometer is designed to register radiated copper K{alpha} and K{beta} lines by using a flat {alpha}-quartz crystal. This experiment uses pre-breakdown x-ray emissions in low vacuum of about 2.5-3 mbar. At this pressure the pinch will not form so the plasma will not radiate. The anode material is copper and the capacity of the capacitor bank is 22.6 nF. This experiment designed and mounted a repetitive triggering system to save the operator time making hundreds of shots. This emission amount is good for calibration and geometrical adjustment of an optical crystal x-ray focusing spectrometer.

  15. Developing small vacuum spark as an x-ray source for calibration of an x-ray focusing crystal spectrometer.

    PubMed

    Ghomeishi, Mostafa; Karami, Mohammad; Adikan, Faisal Rafiq Mahamd

    2012-10-01

    A new technique of x-ray focusing crystal spectrometers' calibration is the desired result. For this purpose the spectrometer is designed to register radiated copper Kα and Kβ lines by using a flat α-quartz crystal. This experiment uses pre-breakdown x-ray emissions in low vacuum of about 2.5-3 mbar. At this pressure the pinch will not form so the plasma will not radiate. The anode material is copper and the capacity of the capacitor bank is 22.6 nF. This experiment designed and mounted a repetitive triggering system to save the operator time making hundreds of shots. This emission amount is good for calibration and geometrical adjustment of an optical crystal x-ray focusing spectrometer. PMID:23126754

  16. Johann Spectrometer for High Resolution X-ray Spectroscopy

    SciTech Connect

    Machek, Pavel; Froeba, Michael; Welter, Edmund; Caliebe, Wolfgang; Brueggmann, Ulf; Draeger, Guenter

    2007-01-19

    A newly designed vacuum Johann spectrometer with a large focusing analyzer crystal for inelastic x-ray scattering and high resolution fluorescence spectroscopy has been installed at the DORIS III storage ring. Spherically bent crystals with a maximum diameter of 125 mm, and cylindrically bent crystals are employed as dispersive optical elements. Standard radius of curvature of the crystals is 1000 mm, however, the design of the mechanical components also facilitates measurements with smaller and larger bending radii. Up to four crystals are mounted on a revolving crystal changer which enables crystal changes without breaking the vacuum. The spectrometer works at fixed Bragg angle. It is preferably designed for the measurements in non-scanning mode with a broad beam spot, and offers a large flexibility to set the sample to the optimum position inside the Rowland circle. A deep depletion CCD camera is employed as a position sensitive detector to collect the energy-analyzed photons on the circumference of the Rowland circle. The vacuum in the spectrometer tank is typically 10-6 mbar. The sample chamber is separated from the tank either by 25 {mu}m thick Kapton windows, which allows samples to be measured under ambient conditions, or by two gate valves. The spectrometer is currently installed at wiggler beamline W1 whose working range is 4-10.5 keV with typical flux at the sample of 5x1010photons/s/mm2. The capabilities of the spectrometer are illustrated by resonant inelastic experiments on 3d transition metals and rare earth compounds, and by chemical shift measurements on chromium compounds.

  17. Johann Spectrometer for High Resolution X-ray Spectroscopy

    NASA Astrophysics Data System (ADS)

    Machek, Pavel; Welter, Edmund; Caliebe, Wolfgang; Brüggmann, Ulf; Dräger, Günter; Fröba, Michael

    2007-01-01

    A newly designed vacuum Johann spectrometer with a large focusing analyzer crystal for inelastic x-ray scattering and high resolution fluorescence spectroscopy has been installed at the DORIS III storage ring. Spherically bent crystals with a maximum diameter of 125 mm, and cylindrically bent crystals are employed as dispersive optical elements. Standard radius of curvature of the crystals is 1000 mm, however, the design of the mechanical components also facilitates measurements with smaller and larger bending radii. Up to four crystals are mounted on a revolving crystal changer which enables crystal changes without breaking the vacuum. The spectrometer works at fixed Bragg angle. It is preferably designed for the measurements in non-scanning mode with a broad beam spot, and offers a large flexibility to set the sample to the optimum position inside the Rowland circle. A deep depletion CCD camera is employed as a position sensitive detector to collect the energy-analyzed photons on the circumference of the Rowland circle. The vacuum in the spectrometer tank is typically 10-6 mbar. The sample chamber is separated from the tank either by 25 μm thick Kapton windows, which allows samples to be measured under ambient conditions, or by two gate valves. The spectrometer is currently installed at wiggler beamline W1 whose working range is 4-10.5 keV with typical flux at the sample of 5×1010photons/s/mm2. The capabilities of the spectrometer are illustrated by resonant inelastic experiments on 3d transition metals and rare earth compounds, and by chemical shift measurements on chromium compounds.

  18. High resolution, high rate X-ray spectrometer

    DOEpatents

    Goulding, Frederick S.; Landis, Donald A.

    1987-01-01

    A pulse processing system (10) for use in an X-ray spectrometer in which a ain channel pulse shaper (12) and a fast channel pulse shaper (13) each produce a substantially symmetrical triangular pulse (f, p) for each event detected by the spectrometer, with the pulse width of the pulses being substantially independent of the magnitude of the detected event and with the pulse width of the fast pulses (p) being substantially shorter than the pulse width of the main channel pulses (f). A pile-up rejector circuit (19) allows output pulses to be generated, with amplitudes linearly related to the magnitude of the detected events, whenever the peak of a main channel pulse (f) is not affected by a preceding or succeeding main channel pulse, while inhibiting output pulses wherein peak magnitudes of main channel pulses are affected by adjacent pulses. The substantially symmetrical triangular main channel pulses (f) are generated by the weighted addition (27-31) of successive RC integrations (24, 25, 26) of an RC differentiated step wave (23). The substantially symmetrical triangular fast channel pulses (p) are generated by the RC integration ( 43) of a bipolar pulse (o) in which the amplitude of the second half is 1/e that of the first half, with the RC time constant of integration being equal to one-half the width of the bipolar pulse.

  19. Estimation of lunar major elemental abundances in Chang'E-3 landing site based on Active Particle-induced X-ray Spectrometer (APXS)

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Wang, Xianmin

    2015-09-01

    Elemental abundance provides an effective vehicle to understand lunar petrologic characteristics and evolutional history. The APXS mounted on the Yutu rover provides a valuable opportunity to determine the major elemental abundances in lunar soil within a short distance. In this study, we processed the APXS spectra including energy calibration, dead time correction and nonlinear least-squares fitting, and determined the abundances of the lunar major elements using the fundamental parameter method. In the calculation of X-ray fluorescence yield, a finite element method (FEM) was employed to improve the accuracy. The major elemental abundances derived from Chang'E-3 (CE-3) APXS possess a good consistency with the result of LP-GRS (Lunar Prospector gamma-ray spectrometer) data in the landing region. Compared with the chemical composition of the returned lunar rock samples, we draw the conclusion that the lunar soils in CE-3 landing site are fragments of mare basalts. Our conclusion is supported by the geological map of Mare Imbrium.

  20. Active microstructured x-ray optical arrays

    NASA Astrophysics Data System (ADS)

    Michette, Alan G.; Pfauntsch, Slawka J.; Sahraei, Shahin; Shand, Matthew; Morrison, Graeme R.; Hart, David; Vojnovic, Boris; Stevenson, Tom; Parkes, William; Dunare, Camelia; Willingale, Richard; Feldman, Charlotte H.; Button, Tim W.; Zhang, Dou; Rodriguez-Sanmartin, Daniel; Wang, Hongchang; Smith, Andy D.

    2009-05-01

    The UK Smart X-Ray Optics consortium is developing novel reflective adaptive/active x-ray optics for small-scale laboratory applications, including studies of radiation-induced damage to biological material. The optics work on the same principle as polycapillaries, using configured arrays of channels etched into thin silicon, such that each x-ray photon reflects at most once off a channel wall. Using two arrays in succession provides two reflections and thus the Abbe sine condition can be approximately satisfied, reducing aberrations. Adaptivity is achieved by flexing one or both arrays using piezo actuation, which can provide further reduction of aberrations as well as controllable focal lengths. Modelling of such arrays for used on an x-ray microprobe, based on a microfocus source with an emitting region approximately 1μm in diameter, shows that a focused flux approximately two orders of magnitude greater than possible with a zone plate of comparable focal length is possible, assuming that the channel wall roughness is less than about 2nm.

  1. A compact high-resolution X-ray ion mobility spectrometer.

    PubMed

    Reinecke, T; Kirk, A T; Heptner, A; Niebuhr, D; Böttger, S; Zimmermann, S

    2016-05-01

    For the ionization of gaseous samples, most ion mobility spectrometers employ radioactive ionization sources, e.g., containing (63)Ni or (3)H. Besides legal restrictions, radioactive materials have the disadvantage of a constant radiation with predetermined intensity. In this work, we replaced the (3)H source of our previously described high-resolution ion mobility spectrometer with 75 mm drift tube length with a commercially available X-ray source. It is shown that the current configuration maintains the resolving power of R = 100 which was reported for the original setup containing a (3)H source. The main advantage of an X-ray source is that the intensity of the radiation can be adjusted by varying its operating parameters, i.e., filament current and acceleration voltage. At the expense of reduced resolving power, the sensitivity of the setup can be increased by increasing the activity of the source. Therefore, the performance of the setup can be adjusted to the specific requirements of any application. To investigate the relation between operating parameters of the X-Ray source and the performance of the ion mobility spectrometer, parametric studies of filament current and acceleration voltage are performed and the influence on resolving power, peak height, and noise is analyzed.

  2. MESSENGER X-Ray Spectrometer Detection of Electron-induced X-ray Fluorescence from Mercury's Surface

    NASA Astrophysics Data System (ADS)

    Starr, R. D.; Nittler, L. R.; Weider, S. Z.; Rhodes, E. A.; Schriver, D.; Schlemm, C. E., II; Solomon, S. C.

    2011-12-01

    The X-Ray Spectrometer (XRS) onboard the MESSENGER spacecraft measures elemental abundances on the surface of Mercury by detecting fluorescent X-ray emissions induced on the planet's surface by the incident solar X-ray flux. The most prominent fluorescent lines are the Kα lines from the elements Mg, Al, Si, S, Ca, Ti, and Fe (1-10 keV). The XRS began orbital observations on 23 March 2011 and has observed X-ray fluorescence from the surface of the planet during both "quiet" Sun and flaring conditions whenever a sunlit portion of Mercury has been within the XRS field of view. XRS can detect the characteristic X-rays of Mg, Al, and Si during quiet-Sun conditions, but solar flares are required to produce measureable signals from the elements of higher atomic number such as S, Ca, Ti, and Fe. Nevertheless, X-ray fluorescence up to the Ca fluorescent line (3.69 keV) has been detected from Mercury's surface at times when the XRS field of view included only unlit portions of the planet or during quiet-Sun illumination. To date, seven such events have been detected and are identified as electron-induced X-ray emission produced by ~1-10 keV electrons interacting with Mercury's surface. Electrons in this energy range were detected by the XRS during the three Mercury flybys, and since the beginning of orbital operations electrons of this same energy range have been detected by XRS during almost every orbit. These electron events last from minutes to tens of minutes. Electron transport models suggest that a large percentage of these quasi-trapped electrons do not complete even a single orbit about Mercury before impacting the surface. Knowledge of the precipitating electron distribution at the planet's surface makes it possible to infer surface composition from the measured fluorescent spectra, providing additional measurement opportunities for the XRS.

  3. EXACT – The Solar X-Ray Spectrometer CubeSat

    NASA Astrophysics Data System (ADS)

    Knuth, Trevor; Glesener, Lindsay; Gebre-Egziabher, Demoz; Vogt, Ryan; Denis, Charles; Weiher, Hannah; Runnels, Joel; Vievering, Juliana

    2016-05-01

    The Experiment for X-ray Characterization and Timing (EXACT) mission will be a CubeSat based hard X-ray spectrometer used for viewing solar flares with high time precision. Solar flares and the related coronal mass ejections affect space weather and the near-Earth environment. EXACT can study the hard X-rays generated by the Sun in the declining phase of Solar Cycle 24 in order to probe electron acceleration in solar eruptive events while also serving as a precursor to future hard X-ray spectrometers that could monitor the Sun continuously.

  4. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    PubMed

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV. PMID:27131669

  5. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    PubMed

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  6. New Solar Soft X-ray Observations from the X123 Spectrometer

    NASA Astrophysics Data System (ADS)

    Caspi, A.; McTiernan, J. M.; Warren, H. P.; Woods, T. N.

    2014-12-01

    The Amptek X123 is a new soft X-ray photon-counting spectrometer, based on a silicon drift detector with integrated thermoelectric cooler, vacuum housing, and multi-channel analyzer (including pulse pile-up rejection), capable of measuring solar line and continuum emission from ~0.5 to ~30 keV with ~0.15 keV FWHM resolution. It was flown on two recent SDO/EVE sounding rocket calibration underflights, is the primary science instrument on the upcoming Miniature X-ray Solar Spectrometer (MinXSS) NASA CubeSat, and is part of the proposed instrument payload for the CubeSat Imaging X-ray Solar Spectrometer (CubIXSS) mission concept. With the best resolution yet obtained from a broadband X-ray spectrometer, the X123 will enable new studies of plasma heating and particle acceleration, during flares and quiescent periods, and help to fill a crucial observational gap from ~0.2 to ~1.2 keV, not currently measured by existing instruments but critical for understanding solar-driven dynamics in Earth's upper atmosphere (ionosphere, thermosphere, mesosphere). We present results from a new analysis of X123 data obtained from the SDO/EVE rocket flights. In preparation for future MinXSS and CubIXSS data, we adapt a recently-developed technique combining EUV and X-ray spectra from SDO/EVE and RHESSI, respectively, to obtain a self-consistent differential emission measure (DEM) over the full range of coronal temperatures, ~2-50 MK. Including the X123 rocket X-ray spectra, we apply the adapted technique to examine both the coronal DEM and composition during quiescent (non-flaring) times with varying activity levels, obtaining constraints on the high-temperature extent of the quiescent DEM, the elemental abundances, and any potential non-thermal emission, and use the observations to extrapolate the spectrum to the poorly-observed ~0.2-1.2 keV band. We compare these results with those from a parallel technique using SDO/AIA imaging data. We discuss the implications for coronal plasma

  7. Development of high throughput X-ray telescopes for X-ray imaging and dispersive spectrometers

    NASA Technical Reports Server (NTRS)

    Gorenstein, P.

    1986-01-01

    During the past year the technical approach to the realization of a high throughput Kirkpatrick-Baez X-ray mirror became better defined in terms of construction methodology and factors which affect maximum size. More progress was made than anticipated in the area of automatic figure formation. However, effort to improve the resolution of float glass by simple techniques were not successful. Mirror development, spectroscopy, all sky telescope, and explorer concept studies are discussed.

  8. Calibration of an imaging crystal spectrometer for low x-ray energies

    SciTech Connect

    Lee, S. G.; Bak, J. G.; Bitter, M.

    2008-01-15

    An x-ray imaging crystal spectrometer was designed for the Hanbit magnetic mirror device to observe spectra of heliumlike neon at 13.4474 A. The spectrometer consists of a spherically bent mica crystal and an x-ray sensitive vacuum charge coupled device camera. This spectrometer can provide spatially resolved spectra, making it possible to obtain profiles of the ion charge state distribution from line ratios and profiles of the plasma rotation velocity from Doppler shift measurements. The paper describes measurements of spectral resolution of this instrument for low x-ray energies.

  9. The hard X-ray burst spectrometer event listing 1980, 1981 and 1982

    NASA Technical Reports Server (NTRS)

    Dennis, B. R.; Frost, K. J.; Orwig, L. E.; Kiplinger, A.; Dennis, H. E.; Gibson, B. R.; Kennard, G. S.; Tolbert, A. K.

    1983-01-01

    A comprehensive reference for the hard X-ray bursts detected with the Hard X-Ray Burst Spectrometer on the Solar Maximum Mission for the time of launch on February 14, 1980 to March 1983 is provided. Over 6300 X-ray events were detected in the energy range from 30 to approx 500 keV with the vast majority being solar flares. The listing includes the start time, peak time, duration and peak rate of each event.

  10. Active x-ray optics for the next generation of x-ray telescopes

    NASA Astrophysics Data System (ADS)

    Atkins, Carolyn; Wang, Hongchang; Doel, Peter; Brooks, David; Thompson, Samantha; Feldman, Charlotte; Willingale, Richard; Button, Tim; Rodriguez Sanmartin, Daniel; Zhang, Dou; James, Ady; Theobald, Craig; Willis, Graham; Smith, Andrew D.

    2009-05-01

    The immediate future for X-ray astronomy is the need for high sensitivity, requiring large apertures and collecting areas, the newly combined NASA, ESA and JAXA mission IXO (International X-ray Observatory) is specifically designed to meet this need. However, looking beyond the next decade, there have been calls for an X-ray space telescope that can not only achieve this high sensitivity, but could also boast an angular resolution of 0.1 arc-seconds, a factor of five improvement on the Chandra X-ray Observatory. NASA's proposed Generation-X mission is designed to meet this demand; it has been suggested that the X-ray optics must be active in nature in order to achieve this desired resolution. The Smart X-ray Optics (SXO) project is a UK based consortium looking at the application of active/adaptive optics to both large and small scale devices, intended for astronomical and medical purposes respectively. With Generation-X in mind, an active elliptical prototype has been designed by the SXO consortium to perform point-to-point X-ray focussing, while simultaneously manipulating its optical surface to improve its initial resolution. Following the completion of the large scale SXO prototype, presented is an overview of the production and operation of the prototype, with emphasis on the X-ray environment and preliminary results.

  11. A Superconducting Tunnel Junction X-ray Spectrometer without Liquid Cryogens

    SciTech Connect

    Friedrich, S; Hertrich, T; Drury, O B; Cherepy, N J; Hohne, J

    2008-06-15

    Superconducting tunnel junctions (STJs) are being developed as X-ray detectors because they combine the high energy resolution of cryogenic detector technologies with the high count rate capabilities of athermal devices. We have built STJ spectrometers for chemical analysis of dilute samples by high-resolution soft X-ray spectroscopy at the synchrotron. The instruments use 36 pixels of 200 {micro}m x 200 {micro}m Nb-Al-AlOx-Al-Nb STJs with 165 nm thick Nb absorber films. They have achieved an energy resolution of {approx}10-20 eV FWHM for X-ray energies below 1 keV, and can be operated at a total count rate of {approx}10{sup 6} counts/s. For increased user-friendliness, we have built a liquid-cryogen-free refrigerator based on a two-stage pulse tube cryocooler in combination with a two-stage adiabatic demagnetization stage. It holds the STJ detector at the end of a 40-cm-long cold finger, and attains the required operating temperature of {approx}0.3 K at the push of a button. We describe the instrument performance and present speciation measurements on Eu dopant activators in the novel scintillator material SrI{sub 2} to illustrate the potential for STJ spectrometers at the synchrotron.

  12. The Mapping X-Ray Fluorescence Spectrometer (MAPX)

    NASA Technical Reports Server (NTRS)

    Blake, David; Sarrazin, Philippe; Bristow, Thomas; Downs, Robert; Gailhanou, Marc; Marchis, Franck; Ming, Douglas; Morris, Richard; Sole, Vincente Armando; Thompson, Kathleen; Walter, Philippe; Wilson, Michael; Yen, Albert; Webb, Samuel

    2016-01-01

    MapX will provide elemental imaging at =100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or alpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray µ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of =100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers = x = 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

  13. Soft x-ray blazed transmission grating spectrometer with high resolving power and extended bandpass

    NASA Astrophysics Data System (ADS)

    Heilmann, Ralf K.; Bruccoleri, Alexander Robert; Schattenburg, Mark

    2016-04-01

    A number of high priority questions in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer, such as the role of Active Galactic Nuclei in galaxy and star formation, characterization of the Warm-Hot Intergalactic Medium and the “missing baryon” problem, characterization of halos around the Milky Way and nearby galaxies, as well as stellar coronae and surrounding winds and disks. An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R = λ/Δλ > 3,000) soft x-ray grating spectrometer is highly feasible based on Critical-Angle Transmission (CAT) grating technology. Still significantly higher performance can be provided by a CAT grating spectrometer on an X-ray-Surveyor-type mission. CAT gratings combine the advantages of blazed reflection gratings (high efficiency, use of higher diffraction orders) with those of conventional transmission gratings (low mass, relaxed alignment tolerances and temperature requirements, transparent at higher energies) with minimal mission resource requirements. They are high-efficiency blazed transmission gratings that consist of freestanding, ultra-high aspect-ratio grating bars fabricated from silicon-on-insulator (SOI) wafers using advanced anisotropic dry and wet etch techniques. Blazing is achieved through grazing-incidence reflection off the smooth grating bar sidewalls. The reflection properties of silicon are well matched to the soft x-ray band. Nevertheless, CAT gratings with sidewalls made of higher atomic number elements allow extension of the CAT grating principle to higher energies and larger dispersion angles. We show x-ray data from metal-coated CAT gratings and demonstrate efficient blazing to higher energies and larger blaze angles than possible with silicon alone. We also report on measurements of the resolving power of a breadboard CAT grating spectrometer consisting of a Wolter-I slumped-glass focusing mirror pair from Goddard Space Flight Center and CAT gratings, to be

  14. Mapping alpha-Particle X-Ray Fluorescence Spectrometer (Map-X)

    NASA Technical Reports Server (NTRS)

    Blake, D. F.; Sarrazin, P.; Bristow, T.

    2014-01-01

    Many planetary surface processes (like physical and chemical weathering, water activity, diagenesis, low-temperature or impact metamorphism, and biogenic activity) leave traces of their actions as features in the size range 10s to 100s of micron. The Mapping alpha-particle X-ray Spectrometer ("Map-X") is intended to provide chemical imaging at 2 orders of magnitude higher spatial resolution than previously flown instruments, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks.

  15. A Johann-type X-ray emission spectrometer at the Rossendorf beamline.

    PubMed

    Kvashnina, Kristina O; Scheinost, Andreas C

    2016-05-01

    This paper gives a detailed description, including equations, of the Johann-type X-ray emission spectrometer which has been recently installed and tested at the Rossendorf beamline (ROBL) of the European Synchrotron Radiation Facility. The spectrometer consists of a single spherically bent crystal analyzer and an avalanche photodiode detector positioned on the vertical Rowland cycle of 1 m diameter. The hard X-ray emission spectrometer (∼3.5-25 keV) operates at atmospheric pressure and covers the Bragg angles of 65°-89°. The instrument has been tested at high and intermediate incident energies, i.e. at the Zr K-edge and at the Au L3-edge, in the second experimental hutch of ROBL. The spectrometer is dedicated for studying actinides in materials and environmental samples by high-energy-resolution X-ray absorption and X-ray emission spectroscopies. PMID:27140166

  16. A Johann-type X-ray emission spectrometer at the Rossendorf beamline.

    PubMed

    Kvashnina, Kristina O; Scheinost, Andreas C

    2016-05-01

    This paper gives a detailed description, including equations, of the Johann-type X-ray emission spectrometer which has been recently installed and tested at the Rossendorf beamline (ROBL) of the European Synchrotron Radiation Facility. The spectrometer consists of a single spherically bent crystal analyzer and an avalanche photodiode detector positioned on the vertical Rowland cycle of 1 m diameter. The hard X-ray emission spectrometer (∼3.5-25 keV) operates at atmospheric pressure and covers the Bragg angles of 65°-89°. The instrument has been tested at high and intermediate incident energies, i.e. at the Zr K-edge and at the Au L3-edge, in the second experimental hutch of ROBL. The spectrometer is dedicated for studying actinides in materials and environmental samples by high-energy-resolution X-ray absorption and X-ray emission spectroscopies.

  17. Future prospects for high resolution X-ray spectrometers

    NASA Technical Reports Server (NTRS)

    Canizares, C. R.

    1981-01-01

    Capabilities of the X-ray spectroscopy payloads were compared. Comparison of capabilities of AXAF in the context of the science to be achieved is reported. The Einstein demonstrated the tremendous scientific power of spectroscopy to probe deeply the astrophysics of all types of celestial X-ray source. However, it has limitations in sensitivity and resolution. Each of the straw man instruments has a sensitivity that is at least an order of magnitude better than that of the Einstein FPSC. The AXAF promises powerful spectral capability.

  18. Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

    NASA Technical Reports Server (NTRS)

    Schnopper, H. W.; Taylor, P. O.

    1981-01-01

    A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

  19. Calibration of a high resolution grating soft x-ray spectrometer

    SciTech Connect

    Magee, E. W.; Dunn, J.; Brown, G. V.; Beiersdorfer, P.; Cone, K. V.; Park, J.; Porter, F. S.; Kilbourne, C. A.; Kelley, R. L.

    2010-10-15

    The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

  20. Calibration of a high resolution grating soft x-ray spectrometer.

    PubMed

    Magee, E W; Dunn, J; Brown, G V; Cone, K V; Park, J; Porter, F S; Kilbourne, C A; Kelley, R L; Beiersdorfer, P

    2010-10-01

    The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 Å waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources. PMID:21034013

  1. Chemistry of Rocks and Soils in Gusev Crater from the Alpha Particle X-ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Gellert, R.; Rieder, R.; Anderson, R. C.; Brueckner, J.; Clark, B. C.; Dreibus, G.; Economou, T.; Klingelhoefer, G.; Lugmair, G. W.; Ming, D. W.

    2005-01-01

    The alpha particle x-ray spectrometer on the Spirit rover determined major and minor elements of soils and rocks in Gusev crater in order to unravel the crustal evolution of planet Mars. The composition of soils is similar to those at previous landing sites, as a result of global mixing and distribution by dust storms. Rocks (fresh surfaces exposed by the rock abrasion tool) resemble volcanic rocks of primitive basaltic composition with low intrinsic potassium contents. High abundance of bromine (up to 170 parts per million) in rocks may indicate the alteration of surfaces formed during a past period of aqueous activity in Gusev crater.

  2. Superconducting High-Resolution X-Ray Spectrometers For Chemical State Analysis Of Dilute Samples

    NASA Astrophysics Data System (ADS)

    Friedrich, Stephan; Drury, Owen B.; Funk, Tobias; Sherrell, Darren; Yachandra, Vittal K.; Labov, Simon E.; Cramer, Stephen P.

    2004-05-01

    Cryogenic X-ray spectrometers operating at temperatures below 1 K combine high energy resolution with broadband efficiency for X-ray energies up to 10 keV. They offer advantages for chemical state analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS) in cases where conventional Ge or Si(Li) detectors lack energy resolution and grating spectrometers lack detection efficiency. We are developing soft X-ray spectrometers based on superconducting Nb-Al-AlOx-Al-Nb tunnel junction (STJ) technology. X-rays absorbed in one of the superconducting electrodes generate excess charge carriers in proportion to their energy, thereby producing a measurable temporary increase in tunneling current. For STJ operation at the synchrotron, we have designed a two-stage adiabatic demagnetization refrigerator (ADR) with a cold finger that holds a 3 × 3 array of STJs inside the UHV sample chamber at a temperature of ˜0.1 K within ˜15 mm of a room temperature sample. Our STJ spectrometer can have an energy resolution below 10 eV FWHM for X-ray energies up to 1 keV, and has total count rate capabilities above 100,000 counts/s. We will describe detector performance in synchrotron-based X-ray fluorescence experiments and demonstrate its use for XAS on a dilute metal site in a metalloprotein.

  3. Quantifying the Sensitivity of Superconducting High-Resolution X-Ray Spectrometers

    SciTech Connect

    Drury, O; Friedrich, S

    2004-10-04

    Superconducting tunnel junction (STJ) X-ray spectrometers have been developed for synchrotron-based high-resolution soft X-ray spectroscopy. We are quantifying the improvements in sensitivity that STJ spectrometers can offer for the analysis of dilute specimens over conventional semiconductor and grating spectrometers. We present analytical equations to quantify the improvements in terms of spectrometer resolution, detection efficiency and count rate capabilities as a function of line separation and spectral background. We discuss the implications of this analysis for L-edge spectroscopy of first-row transition metals.

  4. A high-resolving-power x-ray spectrometer for the OMEGA EP Laser (invited)

    NASA Astrophysics Data System (ADS)

    Nilson, P. M.; Ehrne, F.; Mileham, C.; Mastrosimone, D.; Jungquist, R. K.; Taylor, C.; Stillman, C. R.; Ivancic, S. T.; Boni, R.; Hassett, J.; Lonobile, D. J.; Kidder, R. W.; Shoup, M. J.; Solodov, A. A.; Stoeckl, C.; Theobald, W.; Froula, D. H.; Hill, K. W.; Gao, L.; Bitter, M.; Efthimion, P.; Meyerhofer, D. D.

    2016-11-01

    A high-resolving-power x-ray spectrometer has been developed for the OMEGA EP Laser System based on a spherically bent Si [220] crystal with a radius of curvature of 330 mm and a Spectral Instruments (SI) 800 Series charge-coupled device. The instrument measures time-integrated x-ray emission spectra in the 7.97- to 8.11-keV range, centered on the Cu Kα1 line. To demonstrate the performance of the spectrometer under high-power conditions, Kα1,2 emission spectra were measured from Cu foils irradiated by the OMEGA EP laser with 100-J, 1-ps pulses at focused intensities above 1018 W/cm2. The ultimate goal is to couple the spectrometer to a picosecond x-ray streak camera and measure temperature-equilibration dynamics inside rapidly heated materials. The plan for these ultrafast streaked x-ray spectroscopy studies is discussed.

  5. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

    SciTech Connect

    Kayser, Y.; Błachucki, W.; Dousse, J.-Cl.; Hoszowska, J.; Neff, M.; Romano, V.

    2014-04-15

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

  6. An X-ray Raman spectrometer for EXAFS studies on minerals: bent Laue spectrometer with 20 keV X-rays.

    PubMed

    Hiraoka, N; Fukui, H; Tanida, H; Toyokawa, H; Cai, Y Q; Tsuei, K D

    2013-03-01

    An X-ray Raman spectrometer for studies of local structures in minerals is discussed. Contrary to widely adopted back-scattering spectrometers using ≤10 keV X-rays, a spectrometer utilizing ~20 keV X-rays and a bent Laue analyzer is proposed. The 20 keV photons penetrate mineral samples much more deeply than 10 keV photons, so that high intensity is obtained owing to an enhancement of the scattering volume. Furthermore, a bent Laue analyzer provides a wide band-pass and a high reflectivity, leading to a much enhanced integrated intensity. A prototype spectrometer has been constructed and performance tests carried out. The oxygen K-edge in SiO(2) glass and crystal (α-quartz) has been measured with energy resolutions of 4 eV (EXAFS mode) and 1.3 eV (XANES mode). Unlike methods previously adopted, it is proposed to determine the pre-edge curve based on a theoretical Compton profile and a Monte Carlo multiple-scattering simulation before extracting EXAFS features. It is shown that the obtained EXAFS features are reproduced fairly well by a cluster model with a minimal set of fitting parameters. The spectrometer and the data processing proposed here are readily applicable to high-pressure studies.

  7. Electron-multiplying CCDs for future soft X-ray spectrometers

    NASA Astrophysics Data System (ADS)

    Tutt, J. H.; Holland, A. D.; Murray, N. J.; Harriss, R. D.; Hall, D. J.; Soman, M.

    2012-02-01

    CCDs have been used in several high resolution soft X-ray spectrometers for both space and terrestrial applications such as the Reflection Grating Spectrometer on XMM-Newton and the Super Advanced X-ray Emission Spectrometer at the Paul Scherrer Institut in Switzerland. However, with their ability to use multiplication gain to amplify signal and suppress readout noise, EM-CCDs are being considered instead of CCDs for future soft X-ray spectrometers. When detecting low energy X-rays, EM-CCDs are able to increase the Signal-to-Noise ratio of the device, making the X-rays much easier to detect. If the signal is also significantly split between neighbouring pixels, the increase in the size of the signal will make complete charge collection and techniques such as centroiding easier to accomplish. However, multiplication gain from an EM-CCD does cause a degradation of the energy resolution of the device and there are questions about how the high field region in an EM-CCD will behave over time in high radiation environments. This paper analyses the possible advantages and disadvantages of using EM-CCDs for high resolution soft X-ray spectroscopy and suggests in which situations using them would not only be possible, but also beneficial to the instrument.

  8. Passive Spectroscopy Bolometers, Grating- And X-Ray Imaging Crystal Spectrometers

    SciTech Connect

    Bitter, M; Hill, K W; Scott, S; Paul, S; Ince-Cushmann, A; Reinke, M; Rice, J; Beiersdorfer, P; Gu, M F; Lee, S G; Broennimann, C; Eikenberry, E F

    2007-11-07

    This tutorial gives a brief introduction into passive spectroscopy and describes the working principles of bolometers, a high-resolution grating spectrometer, and a novel X-ray imaging crystal spectrometer, which is of particular interest for profile measurements of the ion temperature and plasma rotation velocity on ITER and future burning plasma experiments.

  9. The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

    NASA Astrophysics Data System (ADS)

    Champey, P. R.; Winebarger, A. R.; Kobayashi, K.; Savage, S. L.; Cirtain, J. W.; Cheimets, P.; Hertz, E.; Golub, L.; Ramsey, B.; McCracken, J.; Heilmann, R.; Schattenburg, M.; Bruccoleri, A.

    2015-12-01

    The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA soundingrocket instrument designed to observe soft X-ray emissions at 0.5 - 2.0 keV energies in thesolar atmosphere. The primary science goal is to differentiate steady, low-frequency heatingevents from sporadic, high-frequency heating events in the active region core For the first time, high-temperature, low-emission plasma will be observed directly with 5 arcsec spatialand 22 mÅ spectral resolution. The novel optical design consists of a Wolter I telescope anda 3-optic grazing-incidence spectrograph. The X-ray spectrograph utilizes a finite conjugatemirror pair and a planar, nanoprinted-silicon varied line space grating, which is being devel-oped by the Massachusetts Institute of Technology (MIT). The telescope and spectrographmirrors will be nickel replicated and coated with iridium. Mandrel fabrication and nickelreplication will be done at MSFC as part of its replicated X-ray optics program. Mounting,alignment, and integration of the ight optics will be performed at the Harvard-SmithsonianCenter for Astrophysics (SAO). The MaGIXS science camera is being developed at MSFCand is based on CLASP heritage, which obtained read noise performance of 5.5 e?- RMS. Thecamera will include a e2v Technologies 2kx2k frame transfer CCD with 4-channel readout(500 kpixel/s/channel). We will present an overview of the MaGIXS optical system andfabrication of the telescope and spectrograph mirrors.

  10. Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron buncha)

    NASA Astrophysics Data System (ADS)

    Kojima, Sadaoki; Arikawa, Yasunobu; Nishimura, Yasuhiko; Togawa, Hiromi; Zhang, Zhe; Ikenouchi, Takahito; Ozaki, Tetsuo; Morace, Alessio; Nagai, Takahiro; Abe, Yuki; Sakata, Shouhei; Inoue, Hiroaki; Utsugi, Masaru; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Kato, Ryukou; Fujioka, Shinsuke; Azechi, Hiroshi

    2014-11-01

    A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons' energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

  11. Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron bunch

    SciTech Connect

    Kojima, Sadaoki Arikawa, Yasunobu; Zhang, Zhe; Ikenouchi, Takahito; Morace, Alessio; Nagai, Takahiro; Abe, Yuki; Sakata, Shouhei; Inoue, Hiroaki; Utsugi, Masaru; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Nishimura, Yasuhiko; Togawa, Hiromi; Ozaki, Tetsuo; Kato, Ryukou

    2014-11-15

    A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons’ energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

  12. Development of a Time-resolved Soft X-ray Spectrometer for Laser Produced Plasma Experiments

    SciTech Connect

    Cone, K V; Dunn, J; Schneider, M B; Baldis, H A; Brown, G V; Emig, J; James, D L; May, M J; Park, J; Shepherd, R; Widmann, K

    2010-05-12

    A 2400 line/mm variable spaced grating spectrometer (VSG) has been used to measure soft x-ray emission (8-22 {angstrom}) from laser-produced plasma experiments at Lawrence Livermore National Laboratory's Compact Multipulse Terrawatt (COMET) Laser Facility. The spectrometer was coupled to a Kentech x-ray streak camera to study the temporal evolution of soft x-rays emitted from the back of mylar and copper foils irradiated at 10{sup 15} W/cm{sup 2}. The instrument demonstrated a resolving power of {approx} 120 at 19 {angstrom} with a time resolution of 31 ps. The time-resolved copper emission spectrum was consistent with a photodiode monitoring the laser temporal pulse shape and indicated that the soft x-ray emission follows the laser heating of the target. The time and spectral resolution of this diagnostic make it useful for studies of high temperature plasmas.

  13. Calibration of a Flat Field Soft X-ray Grating Spectrometer for Laser Produced Plasmas

    SciTech Connect

    Park, J; Brown, G V; Schneider, M B; Baldis, H A; Beiersdorfer, P; Cone, K V; Kelley, R L; Kilbourne, C A; Magee, E; May, M J; Porter, F S

    2010-05-12

    We have calibrated the x ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL, and at both the Omega and Omega EP lasers at University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range from {approx} 6 to 60 {angstrom}. The calibration results present here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from hydrogen-like and helium-like ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x ray intensities recorded by the VSG to those simultaneously recorded by an x ray microcalorimeter spectrometer.

  14. Thermal design and performance of the REgolith x-ray imaging spectrometer (REXIS) instrument

    NASA Astrophysics Data System (ADS)

    Stout, Kevin D.; Masterson, Rebecca A.

    2014-08-01

    The REgolith X-ray Imaging Spectrometer (REXIS) instrument is a student collaboration instrument on the OSIRIS-REx asteroid sample return mission scheduled for launch in September 2016. The REXIS science mission is to characterize the elemental abundances of the asteroid Bennu on a global scale and to search for regions of enhanced elemental abundance. The thermal design of the REXIS instrument is challenging due to both the science requirements and the thermal environment in which it will operate. The REXIS instrument consists of two assemblies: the spectrometer and the solar X-ray monitor (SXM). The spectrometer houses a 2x2 array of back illuminated CCDs that are protected from the radiation environment by a one-time deployable cover and a collimator assembly with coded aperture mask. Cooling the CCDs during operation is the driving thermal design challenge on the spectrometer. The CCDs operate in the vicinity of the electronics box, but a 130 °C thermal gradient is required between the two components to cool the CCDs to -60 °C in order to reduce noise and obtain science data. This large thermal gradient is achieved passively through the use of a copper thermal strap, a large radiator facing deep space, and a two-stage thermal isolation layer between the electronics box and the DAM. The SXM is mechanically mounted to the sun-facing side of the spacecraft separately from the spectrometer and characterizes the highly variable solar X-ray spectrum to properly interpret the data from the asteroid. The driving thermal design challenge on the SXM is cooling the silicon drift detector (SDD) to below -30 °C when operating. A two-stage thermoelectric cooler (TEC) is located directly beneath the detector to provide active cooling, and spacecraft MLI blankets cover all of the SXM except the detector aperture to radiatively decouple the SXM from the flight thermal environment. This paper describes the REXIS thermal system requirements, thermal design, and analyses, with

  15. The spectrometer/telescope for imaging X-rays on board the ESA Solar Orbiter spacecraft

    NASA Astrophysics Data System (ADS)

    Krucker, S.; Benz, A. O.; Hurford, G. J.; Arnold, N. G.; Orleański, P.; Gröbelbauer, H.-P.; Casadei, D.; Kobler, S.; Iseli, L.; Wiehl, H. J.; Csillaghy, A.; Etesi, L.; Hochmuth, N.; Battaglia, M.; Bednarzik, M.; Resanovic, R.; Grimm, O.; Viertel, G.; Commichau, V.; Howard, A.; Meuris, A.; Limousin, O.; Brun, S.; Vilmer, N.; Skup, K. R.; Graczyk, R.; Stolarski, M.; Michalska, M.; Nowosielski, W.; Cichocki, A.; Mosdorf, M.; Seweryn, K.; Białek, A.; Sylwester, J.; Kowalinski, M.; Mrozek, T.; Podgorski, P.; Mann, G.; Önel, H.; Aurass, H.; Bauer, S.-M.; Bittner, W.; Dionies, F.; Paschke, J.; Plüschke, D.; Popow, E.; Rendtel, J.; Warmuth, A.; Woche, M.; Wolter, D.; Van Beek, H. F.; Farnik, F.; Lin, R. P.

    2013-12-01

    Solar Orbiter is a Sun-observing mission led by the European Space Agency, addressing the interaction between the Sun and the heliosphere. It will carry ten instruments, among them the X-ray imaging spectrometer STIX. STIX will determine the intensity, spectrum, timing, and location of thermal and accelerated electrons near the Sun through their bremsstrahlung X-ray emission. This report gives a brief overview of the STIX scientific goals and covers in more detail the instrument design and challenges.

  16. High Gain, Fast Scan, Broad Spectrum, Parallel Beam Wavelength Dispersive X-ray Spectrometer for SEM

    SciTech Connect

    David OHara; Dr. Eric Lochmer

    2003-09-12

    Parallax Research, Inc. proposes to produce a new type of x-ray spectrometer for use with Scanning Electron Microscopy (SEM) that would have the energy resolution of WDS and the ease of use of EDS with sufficient gain for lower energies that it can be used at low beam currents as is EDS. Parallax proposes to do this by development of new multiple reflection x-ray collimation optics, new diffractor technology, new detector technology and new scan algorithms.

  17. The complete Hard X Ray Burst Spectrometer event list, 1980-1989

    NASA Technical Reports Server (NTRS)

    Dennis, B. R.; Orwig, L. E.; Kennard, G. S.; Labow, G. J.; Schwartz, R. A.; Shaver, A. R.; Tolbert, A. K.

    1991-01-01

    This event list is a comprehensive reference for all Hard X ray bursts detected with the Hard X Ray Burst Spectrometer on the Solar Maximum Mission from the time of launch on Feb. 14, 1980 to the end of the mission in Dec. 1989. Some 12,776 events were detected in the energy range 30 to 600 keV with the vast majority being solar flares. This list includes the start time, peak time, duration, and peak rate of each event.

  18. Volume 1. Preliminary design study: AXAF x ray calibration spectrometers. Volume 2. Revised preliminary design study: AXAF x ray calibration spectrometers

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The objective of this work was to provide a preliminary design concept for a Flux Monitor Spectrometer (FMS) for use at the X Ray Astrophysics Facility (XRAF) during High Resolution Mirror Assembly (HRMA) testing that met the requirements of SAO-AXAF-88-025 dated July 31, 1991. The calibration test team determined that the spectral resolution of the FMS had to be greater than or equal to twice that of all the AXAF spectrometers throughout the 0.1 to 10 KeV range of x-ray energies. Since this effectively doubled the resolution required by SAO-AXAF-88-025, a change order was approved by the Marshall Space Flight Center and given to Radiation Sciences to revise their study.

  19. High gain, Fast Scan, Broad Spectrum Parallel Beam Wavelength Dispersive X-ray Spectrometer for SEM

    SciTech Connect

    OHara, David

    2009-05-08

    During contract # DE-FG02-ER83545, Parallax Research, Inc. developed a High gain, Fast Scan Broad Spectrum Parallel beam Wavelength Dispersive X-ray Spectrometer for use on Scanning Electron Microscopes (SEM). This new spectrometer allows very fast high resolution elemental analysis of samples in an electron microscope. By comparison to previous WDS spectrometers, it can change from one energy position to another very quickly and has an extended range compared to some similar products.

  20. Time-resolved near-edge x-ray absorption fine structure spectroscopy on photo-induced phase transitions using a tabletop soft-x-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Grossmann, P.; Rajkovic, I.; Moré, R.; Norpoth, J.; Techert, S.; Jooss, C.; Mann, Klaus

    2012-05-01

    We present a table-top soft-x-ray spectrometer for the wavelength range λ = 1-5 nm based on a stable laser-driven x-ray source, making use of a gas-puff target. With this setup, optical light-pump/soft-x-ray probe near-edge x-ray absorption fine structure (NEXAFS) experiments with a temporal resolution of about 230 ps are feasible. Pump-probe NEXAFS measurements were carried out in the "water-window" region (2.28 nm-4.36 nm) on the manganite Pr0.7Ca0.3MnO3, investigating diminutive changes of the oxygen K edge that derive from an optically induced phase transition. The results show the practicability of the table-top soft-x-ray spectrometer on demanding investigations so far exclusively conducted at synchrotron radiation sources.

  1. Double conical crystal x-ray spectrometer for high resolution ultrafast x-ray absorption near-edge spectroscopy of Al K edge

    SciTech Connect

    Levy, A.; Dorchies, F.; Fourment, C.; Harmand, M.; Hulin, S.; Santos, J. J.; Descamps, D.; Petit, S.; Bouillaud, R.

    2010-06-15

    An x-ray spectrometer devoted to dynamical studies of transient systems using the x-ray absorption fine spectroscopy technique is presented in this article. Using an ultrafast laser-induced x-ray source, this optical device based on a set of two potassium acid phthalate conical crystals allows the extraction of x-ray absorption near-edge spectroscopy structures following the Al absorption K edge. The proposed experimental protocol leads to a measurement of the absorption spectra free from any crystal reflectivity defaults and shot-to-shot x-ray spectral fluctuation. According to the detailed analysis of the experimental results, a spectral resolution of 0.7 eV rms and relative fluctuation lower than 1% rms are achieved, demonstrated to be limited by the statistics of photon counting on the x-ray detector.

  2. A preliminary design study for a cosmic X-ray spectrometer

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The results are described of theoretical and experimental investigations aimed at the development of a curved crystal cosmic X-ray spectrometer to be used at the focal plane of the large orbiting X-ray telescope on the third High Energy Astronomical Observatory. The effort was concentrated on the development of spectrometer concepts and their evaluation by theoretical analysis, computer simulation, and laboratory testing with breadboard arrangements of crystals and detectors. In addition, a computer-controlled facility for precision testing and evaluation of crystals in air and vacuum was constructed. A summary of research objectives and results is included.

  3. Ion-induced x-ray studies with a high luminosity von Hamos crystal spectrometer

    SciTech Connect

    Vane, C.R.; Smith, M.; Raman, S.; Heard, J.; Walkiewicz, T.

    1986-01-01

    A high-resolution, high-efficiency, von Hamos geometry, Bragg crystal x-ray spectrometer has been developed and mounted on a beamline at the Holifield Heavy Ion Research Facility at the Oak Ridge National Laboratory. Measurements have been made of K and L x-rays emitted from a variety of targets and projectiles. Instrument performance characteristics are reported here along with spectra from fast projectile ions and very low intensity target emission - areas of measurement for which this spectrometer is especially suitable.

  4. Toward a soft x-ray Fourier-transform spectrometer

    SciTech Connect

    Howells, M.R.; Frank, K.; Hussain, Z.; Moler, E.J.; Reich, T. |; Moeller, D.; Shirley, D.A.

    1993-10-29

    The use of Fourier transform spectroscopy (FTS) in the soft x-ray region is advocated as a possible route to spectral resolution superior to that attainable with a grating system. A technical plan is described for applying FTS to the study of the absorption spectrum of helium in the region of double ionization around 60--80 eV. The proposed scheme includes a Mach-Zehnder interferometer deformed into a rhombus shape to provide grazing incidence reflections. The path difference between the interfering beams is to be tuned by translation of a table carrying four mirrors over a range {+-}1 cm which, in the absence of errors generating relative tilts of the wave fronts, would provide a resolving power equal to the number of waves of path difference: half a million at 65 eV, for example. The signal-to-noise ratio of the spectrum is analyzed and for operation on an Advanced Light Source bending magnet beam line should be about 330.

  5. Convex crystal x-ray spectrometer for laser plasma experiments

    SciTech Connect

    May, M.; Heeter, R.; Emig, J.

    2004-10-01

    Measuring time and space-resolved spectra is important for understanding Hohlraum and Halfraum plasmas. Experiments at the OMEGA laser have used the Nova TSPEC which was not optimized for the OMEGA diagnostic space envelope or for the needed spectroscopic coverage and resolution. An improved multipurpose spectrometer snout, the MSPEC, has been constructed and fielded on OMEGA. The MSPEC provides the maximal internal volume for mounting crystals without any beam interferences at either 2x or 3x magnification. The RAP crystal is in a convex mounting geometry bent to a 20 cm radius of curvature. The spectral resolution, E/dE, is about 200 at 2.5 keV. The spectral coverage is 2 to 4.5 keV. The MSPEC can record four separate spectra on the framing camera at time intervals of up to several ns. The spectrometer design and initial field-test performance will be presented and compared to that of the TSPEC.

  6. A table-top femtosecond time-resolved soft x-ray transient absorption spectrometer

    SciTech Connect

    Leone, Stephen; Loh, Zhi-Heng; Khalil, Munira; Correa, Raoul E.; Leone, Stephen R.

    2008-05-21

    A laser-based, table-top instrument is constructed to perform femtosecond soft x-ray transient absorption spectroscopy. Ultrashort soft x-ray pulses produced via high-order harmonic generation of the amplified output of a femtosecond Ti:sapphire laser system are used to probe atomic core-level transient absorptions in atoms and molecules. The results provide chemically specific, time-resolved dynamics with sub-50-fs time resolution. In this setup, high-order harmonics generated in a Ne-filled capillary waveguide are refocused by a gold-coated toroidal mirror into the sample gas cell, where the soft x-ray light intersects with an optical pump pulse. The transmitted high-order harmonics are spectrally dispersed with a home-built soft x-ray spectrometer, which consists of a gold-coated toroidal mirror, a uniform-line spaced plane grating, and a soft x-ray CCD camera. The optical layout of the instrument, design of the soft x-ray spectrometer, and spatial and temporal characterization of the high-order harmonics are described. Examples of static and time-resolved photoabsorption spectra collected on this apparatus are presented.

  7. Rest-wavelength Fiducials for the ITER Core Imaging X-ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Beiersdorfer, P.; Brown, G. V.; Graf, A. T.; Bitter, M.; Hill, K. W.; Kelley, R. L.; Kilbourne, C. A.; Leutenegger, M. A.; Porter, F. S.

    2012-01-01

    Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W64+, which has become the line of choice for the ITER (Latin the way) core imaging x-ray spectrometer. Close-by standards are the Hf L3 line and the Ir L2 line, which bracket the W64+ line by 30 eV; other standards are given by the Ir L1 and L2 lines and the Hf L1 and L2 lines, which bracket the W64+ line by 40 and 160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W64+ line obtained both with an x-ray microcalorimeter and a crystal spectrometer

  8. Rest-wavelength fiducials for the ITER core imaging x-ray spectrometer.

    PubMed

    Beiersdorfer, P; Brown, G V; Graf, A T; Bitter, M; Hill, K W; Kelley, R L; Kilbourne, C A; Leutenegger, M A; Porter, F S

    2012-10-01

    Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W(64+), which has become the line of choice for the ITER (Latin "the way") core imaging x-ray spectrometer. Close-by standards are the Hf Lβ(3) line and the Ir Lα(2) line, which bracket the W(64+) line by ±30 eV; other standards are given by the Ir Lα(1) and Lα(2) lines and the Hf Lβ(1) and Lβ(2) lines, which bracket the W(64+) line by ±40 and ±160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W(64+) line obtained both with an x-ray microcalorimeter and a crystal spectrometer.

  9. X-ray emission from active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Mushotzky, R.

    1985-01-01

    It is often held that the X-ray emission from active galactic nuclei (AGN) arises from a region close to the central energy source. Thus X-ray observations may provide the best constraints on the central engine. In particular, the shape of the X-ray continuum gives information about the mechanism for photon generation, X-ray time variability data can constrain the size and mass of the continuum source, and X-ray occultation data give constraints on the relative sizes of the continuum source and the intervening absorbing material (often assumed to be the broad line clouds). In addition, since a fair fraction of the total energy of an AGN is emitted at X-ray wavelengths, direct measurement of the amount and spectral form of this radiation is important for modeling of the optically emitting clouds.

  10. Fast fluctuations of soft X-rays from active regions

    NASA Technical Reports Server (NTRS)

    Simnett, G. F.; Dennis, B. R.

    1986-01-01

    A selection of short lived small soft X-ray bursts is studied using data from the Hard X-ray Imaging Spectrometer (HXIS), and the results are compared with the data from the Hard X-Ray Burst Spectrometer (HXRBS) with a view to understanding conditions at the onset of flares. Short-lived events provide an opportunity to study the radiation from the primary energy transfer process without confusion from the slowly-varying thermal X-ray emission which characterizes the decay of a large flare. The fast decay of the soft X-rays, only a few tens of seconds, suggests that they occur in the dense chromosphere. The results indicate that the short events may be signatures of several different phenomena, depending on their characteristics. Some events occur in association with reverse-drift type III bursts and simultaneous flaring elsewhere on the Sun, thus suggesting dumping of particles accelerated at a remote site. Some events have hard X-ray bursts and normal type III bursts associated with them, while others have neither. The latter events place strong constraints on the nonthermal electron population present.

  11. High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

    NASA Technical Reports Server (NTRS)

    Porter, Frederick S.

    2010-01-01

    X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray

  12. [High-Performance Active Pixel X-Ray Sensors for X-Ray Astronomy

    NASA Technical Reports Server (NTRS)

    Bautz, Mark; Suntharalingam, Vyshnavi

    2005-01-01

    The subject grants support development of High-Performance Active Pixel Sensors for X-ray Astronomy at the Massachusetts Institute of Technology (MIT) Center for Space Research and at MIT's Lincoln Laboratory. This memo reports our progress in the second year of the project, from April, 2004 through the present.

  13. Convex Crystal X-ray Spectrometer for Laser Plasma Experiments

    SciTech Connect

    May, M; Heeter, R; Emig, J

    2004-04-15

    Measuring time and space-resolved spectra is important for understanding Hohlraum and Halfraum plasmas. Experiments at the OMEGA laser have used the Nova TSPEC which was not optimized for the OMEGA diagnostic space envelope or for the needed spectroscopic coverage and resolution. An improved multipurpose spectrometer snout, the MSPEC, has been constructed and fielded on OMEGA. The MSPEC provides the maximal internal volume for mounting crystals without any beam interferences at either 2x or 3x magnification. The RAP crystal is in a convex mounting geometry bent to a 20 cm radius of curvature. The spectral resolution, E/dE, is about 200 at 2.5 keV. The spectral coverage is 2 to 4.5 keV. The MSPEC can record four separate spectra on the framing camera at time intervals of up to several ns. The spectrometer design and initial field-test performance will be presented and compared to that of the TSPEC. Work supported by U. S. DoE/UC LLNL contract W-7405-ENG-48

  14. Rocket studies of solar corona and transition region. [X-Ray spectrometer/spectrograph telescope

    NASA Technical Reports Server (NTRS)

    Acton, L. W.; Bruner, E. C., Jr.; Brown, W. A.; Nobles, R. A.

    1979-01-01

    The XSST (X-Ray Spectrometer/Spectrograph Telescope) rocket payload launched by a Nike Boosted Black Brant was designed to provide high spectral resolution coronal soft X-ray line information on a spectrographic plate, as well as time resolved photo-electric records of pre-selected lines and spectral regions. This spectral data is obtained from a 1 x 10 arc second solar region defined by the paraboloidal telescope of the XSST. The transition region camera provided full disc images in selected spectral intervals originating in lower temperature zones than the emitting regions accessible to the XSST. A H-alpha camera system allowed referencing the measurements to the chromospheric temperatures and altitudes. Payload flight and recovery information is provided along with X-ray photoelectric and UV flight data, transition camera results and a summary of the anomalies encountered. Instrument mechanical stability and spectrometer pointing direction are also examined.

  15. Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

    SciTech Connect

    Gnesin, S.; Coda, S.; Decker, J.; Peysson, Y.

    2008-10-15

    Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

  16. A Soft X-ray Spectrometer using a Highly Dispersive Multilayer Grating

    NASA Astrophysics Data System (ADS)

    Warwick, Tony; Padmore, Howard; Voronov, Dmitriy; Yashchuk, Valeriy

    2010-06-01

    There is a need for higher resolution spectrometers as a tool for inelastic x-ray scattering. Currently, resolving power around R = 10,000 is advertised. Measured RIXS spectra are often limited by this instrumental resolution and higher resolution spectrometers using conventional gratings would be prohibitively large. We are engaged in a development program to build blazed multilayer grating structures for diffracting soft x-rays in high order. This leads to spectrometers with dispersion much higher than is possible using metal coated-gratings. The higher dispersion then provides higher resolution and the multilayer gratings are capable of operating away from grazing incidence as required. A spectrometer design is presented with a total length 3.8 m and capable of 105 resolving power.

  17. A Soft X-ray Spectrometer using a Highly Dispersive Multilayer Grating

    SciTech Connect

    Warwick, Tony; Padmore, Howard; Voronov, Dmitriy; Yashchuk, Valeriy

    2010-01-31

    There is a need for higher resolution spectrometers as a tool for inelastic x-ray scattering. Currently, resolving power around R = 10,000 is advertised. Measured RIXS spectra are often limited by this instrumental resolution and higher resolution spectrometers using conventional gratings would be prohibitively large. We are engaged in a development program to build blazed multilayer grating structures for diffracting soft x-rays in high order. This leads to spectrometers with dispersion much higher than is possible using metal coated-gratings. The higher dispersion then provides higher resolution and the multilayer gratings are capable of operating away from grazing incidence as required. A spectrometer design is presented with a total length 3.8m and capable of 10{sup 5} resolving power.

  18. Calibration of a gated flat field spectrometer as a function of x-ray intensity

    SciTech Connect

    Xiong, Gang; Yang, Guohong; Li, Hang; Zhang, Jiyan Zhao, Yang; Hu, Zhimin; Wei, Minxi; Qing, Bo; Yang, Jiamin; Liu, Shenye; Jiang, Shaoen

    2014-04-15

    We present an experimental determination of the response of a gated flat-field spectrometer at the Shenguang-II laser facility. X-rays were emitted from a target that was heated by laser beams and then were divided into different intensities with a step aluminum filter and collected by a spectrometer. The transmission of the filter was calibrated using the Beijing Synchrotron Radiation Facility. The response characteristics of the spectrometer were determined by comparing the counts recorded by the spectrometer with the relative intensities of the x-rays transmitted through the step aluminum filter. The response characteristics were used to correct the transmission from two shots of an opacity experiment using the same samples. The transmissions from the two shots are consistent with corrections, but discrepant without corrections.

  19. Calibration of a gated flat field spectrometer as a function of x-ray intensity

    NASA Astrophysics Data System (ADS)

    Xiong, Gang; Yang, Guohong; Li, Hang; Zhang, Jiyan; Zhao, Yang; Hu, Zhimin; Wei, Minxi; Qing, Bo; Yang, Jiamin; Liu, Shenye; Jiang, Shaoen

    2014-04-01

    We present an experimental determination of the response of a gated flat-field spectrometer at the Shenguang-II laser facility. X-rays were emitted from a target that was heated by laser beams and then were divided into different intensities with a step aluminum filter and collected by a spectrometer. The transmission of the filter was calibrated using the Beijing Synchrotron Radiation Facility. The response characteristics of the spectrometer were determined by comparing the counts recorded by the spectrometer with the relative intensities of the x-rays transmitted through the step aluminum filter. The response characteristics were used to correct the transmission from two shots of an opacity experiment using the same samples. The transmissions from the two shots are consistent with corrections, but discrepant without corrections.

  20. Preliminary testing of a prototype portable X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Patten, L. L.; Anderson, N. B.; Stevenson, J. J.

    1982-08-01

    A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

  1. Preliminary testing of a prototype portable X-ray fluorescence spectrometer

    NASA Technical Reports Server (NTRS)

    Patten, L. L.; Anderson, N. B.; Stevenson, J. J.

    1982-01-01

    A portable X-ray fluorescence spectrometer for use as an analyzer in mineral resource investigative work was built and tested. The prototype battery powered spectrometer, measuring 11 by 12 by 5 inches and weighing only about 15 pounds, was designed specifically for field use. The spectrometer has two gas proportional counters and two radioactive sources, Cd (10a) and Fe (55). Preliminary field and laboratory tests on rock specimens and rock pulps have demonstrated the capability of the spectrometer to detect 33 elements to date. Characteristics of the system present some limitations, however, and further improvements are recommended.

  2. Apollo lunar orbital sciences program alpha and X-ray spectrometers

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The development of the alpha and X-ray spectrometers which were used on the Apollo 15 and 16 flights is discussed. Specific subjects presented are: (1) lunar program management, (2) scientific and technical approach, (3) major test programs, (4) reliability, quality assurance, and safety, and (5) subcontract management.

  3. Triple-path collector optics for grazing incident x-ray emission spectrometer

    NASA Astrophysics Data System (ADS)

    Tokushima, T.; Horikawa, Y.; Shin, S.

    2011-07-01

    A new type of collector optics was developed for grazing incident x-ray emission spectrometer. The collector optics used two cylindrical mirrors to add two extra light paths while keeping the center light path that directly illuminates the grating. The design and properties of the spectrometer using the triple-path collector optics were evaluated using ray-tracing simulations, and validity of this design in terms of throughput and energy resolution was confirmed by the experimentally obtained spectra.

  4. Triple-path collector optics for grazing incident x-ray emission spectrometer.

    PubMed

    Tokushima, T; Horikawa, Y; Shin, S

    2011-07-01

    A new type of collector optics was developed for grazing incident x-ray emission spectrometer. The collector optics used two cylindrical mirrors to add two extra light paths while keeping the center light path that directly illuminates the grating. The design and properties of the spectrometer using the triple-path collector optics were evaluated using ray-tracing simulations, and validity of this design in terms of throughput and energy resolution was confirmed by the experimentally obtained spectra. PMID:21806173

  5. Atomic data for the ITER Core Imaging X-ray Spectrometer

    SciTech Connect

    Clementson, J; Beiersdorfer, P; Biedermann, C; Bitter, M; Delgado-Aparicio, L F; Graf, A; Gu, M F; Hill, K W; Barnsley, R

    2012-06-15

    The parameters of the ITER core plasmas will be measured using the Core Imaging X-ray Spectrometer (CIXS), a high-resolution crystal spectrometer focusing on the L-shell spectra of highly ionized tungsten atoms. In order to correctly infer the plasma properties accurate atomic data are required. Here, some aspects of the underlying physics are discussed using experimental data and theoretical predictions from modeling.

  6. A Liquid-Cryogen-Free Superconducting Tunnel Junction X-ray Spectrometer for Astrobiology Research at the Synchrotron

    SciTech Connect

    Friedrich, S; Drury, O B; Hertrich, T; Hoehne, J

    2008-06-15

    Superconducting tunnel junctions (STJs) are being developed as energy-dispersive soft X-ray detectors, because they combine the high energy resolution of low-temperature detectors with the comparably high count rates of non-thermal devices. We have built a 36-pixel spectrometer based on 200 {micro}m x 200 {micro}m Nb-Al-AlOx-Al-Nb STJs. It offers an energy resolution of {approx}10 to 20 eV FWHM in the soft X-ray band below 1 keV, a solid angle coverage {Omega}/4{pi} {approx} 10{sup -3}, and can be operated at total rates up to {approx}10{sup 6} counts/s. For STJ operation by non-expert users, we have built a liquid-cryogen-free spectrometer with a mechanical pulse-tube cryocooler and a two-stage adiabatic demagnetization refrigerator. It is fully automated for cooldown to a base temperature of <30 mK in 15 hours, and has a hold time of >3 days between demagnetization cycles for STJ operation at 0.3 K. The STJ spectrometers are used for speciation measurements on dilute samples by fluorescence-detected X-ray absorption spectroscopy, and can achieve sensitivities below 100 ppm. We discuss the spectrometer performance in representative applications on metals in meteorites in the context of geological signatures of biological activity.

  7. The X-ray Microcalorimeter Spectrometer (XMS): A Reference Cryogenic Instrument Design for Constellation-X

    NASA Technical Reports Server (NTRS)

    Whitehouse, Paul L.

    2003-01-01

    Constellation-X, a mission now belonging to the Beyond Einstein initiative, is being planned to inherit the x-ray sky from Chandra, XMM-Newton and Astro-E. The first two of four observatories in the constellation will be launched together in 2013 and followed a year later by the launch of the remaining two. The four will independently orbit the Sun-Earth Lagrange point L2. An instrument compliment resides in the Focal Plane Module (FPM) of each observatory 10 m from the Optics Module and consists of three Hard X-ray Telescope (HXT) detectors, a Reflection Grating Spectrometer (RGS) focal plane CCD camera and an X-ray Microcalorimeter Spectrometer (XMS). Instrument awards are scheduled for early 2006. The reference detector for XMS is a 32 x 32 array of microcalorimetric superconducting Transition Edge Sensors (TES). Each pixel casts a variable resistance in a SQUID based multiplexed readout circuit which is coupled to series SQUID arrays for amplification and finally read out by external electronics. A multi-stage continuous ADR will provide the stable 50 mK desired for the TES array and a stable 1 K for the series SQUID arrays while also lifting thermal parasitic and inefficiency loads to a 6 K cryocooler interface. The 6 K cryocooler is expected to emerge from the joint-project Advanced Cryocooler Technology Development Program (ACTDP) in which Constellation-X is an active participant. Project Pre-Formulation activities are marked by extensive technology development necessitating early, but realistic, thermal and cooling load requirements for ADR and ACTDP-cryocooler design points. Such requirements are driven by the encompassing XMS cryostat and ultimately by the thermal environment imposed by the FPM. It is further desired that the XMS instrument be able to operate on its side in the laboratory, with a warm vacuum shell, during an extensive calibration regime. It is that reference system design of the XMS instrument (microcalorimeter, ADR, cryocooler and

  8. REgolith X-Ray Imaging Spectrometer (REXIS) Aboard NASA’s OSIRIS-REx Mission

    NASA Astrophysics Data System (ADS)

    Hong, JaeSub; Allen, Branden; Grindlay, Jonathan E.; Binzel, Richard P.; Masterson, Rebecca; Inamdar, Niraj K; Chodas, Mark; Smith, Matthew W; Bautz, Mark W.; Kissel, Steven E; Villasenor, Jesus Noel; Oprescu, Antonia

    2014-06-01

    The REgolith X-Ray Imaging Spectrometer (REXIS) is a student-led instrument being designed, built, and operated as a collaborative effort involving MIT and Harvard. It is a part of NASA's OSIRIS-REx mission, which is scheduled for launch in September of 2016 for a rendezvous with, and collection of a sample from the surface of the primitive carbonaceous chondrite-like asteroid 101955 Bennu in 2019. REXIS will determine spatial variations in elemental composition of Bennu's surface through solar-induced X-ray fluorescence. REXIS consists of four X-ray CCDs in the detector plane and an X-ray mask. It is the first coded-aperture X-ray telescope in a planetary mission, which combines the benefit of high X-ray throughput of wide-field collimation with imaging capability of a coded-mask, enabling detection of elemental surface distributions at approximately 50-200 m scales. We present an overview of the REXIS instrument and the expected performance.

  9. Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants

    NASA Technical Reports Server (NTRS)

    Thornton, Michael G. (Inventor); Clark, III, Benton C. (Inventor)

    1991-01-01

    A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.

  10. A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies

    SciTech Connect

    Szlachetko, J.; Nachtegaal, M.; Boni, E. de; Willimann, M.; Safonova, O.; Sa, J.; Smolentsev, G.; Szlachetko, M.; Bergamaschi, A.; Schmitt, B.; David, C.; Luecke, A.; Bokhoven, J. A. van; Dousse, J.-Cl.; Hoszowska, J.; Kayser, Y.; Jagodzinski, P.

    2012-10-15

    We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV-9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation that allows to preserve the spectrometer resolution and spectrometer efficiency. Application of the spectrometer for time-resolved resonant inelastic x-ray scattering and single-shot x-ray emission spectroscopy is demonstrated.

  11. A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies.

    PubMed

    Szlachetko, J; Nachtegaal, M; de Boni, E; Willimann, M; Safonova, O; Sa, J; Smolentsev, G; Szlachetko, M; van Bokhoven, J A; Dousse, J-Cl; Hoszowska, J; Kayser, Y; Jagodzinski, P; Bergamaschi, A; Schmitt, B; David, C; Lücke, A

    2012-10-01

    We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV-9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation that allows to preserve the spectrometer resolution and spectrometer efficiency. Application of the spectrometer for time-resolved resonant inelastic x-ray scattering and single-shot x-ray emission spectroscopy is demonstrated.

  12. An X-ray refractive lens comprising two sections cut from a gramophone record for a portable total reflection X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-08-01

    An X-ray refractive lens is assembled from two sections cut from a gramophone record. The refractive lens is placed in a portable total reflection X-ray fluorescence (TXRF) spectrometer, and it is used for collimation of the incident X-ray beams. A TXRF spectrum measured with the refractive lens is compared with that measured with a waveguide. Compared with the refractive lens, the waveguide enhances the intensities of the X-rays illuminating an analyte. Therefore, fluorescent X-ray intensities increase when using the waveguide. On the other hand, the vertical angular divergence of the incident X-ray beams is smaller when using the refractive lens, and the smaller angular divergence results in a reduction of the scattering of the incident X-rays from a sample holder. Therefore, the spectral background is reduced when using the refractive lens, resulting in an increase of the signal to background ratios of the fluorescent X-rays. Detection limits for 3d transition metals obtained with the refractive lens are sub-nanograms to a few nanograms, and the detection limits are similar to those obtained with the waveguide.

  13. Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak

    SciTech Connect

    Yan, W.; Chen, Z. Y. Jin, W.; Huang, D. W.; Ding, Y. H.; Li, J. C.; Zhang, X. Q.; Zhuang, G.; Lee, S. G.; Shi, Y. J.

    2014-11-15

    The wavelength calibration of x-ray imaging crystal spectrometer is a key issue for the measurements of plasma rotation. For the lack of available standard radiation source near 3.95 Å and there is no other diagnostics to measure the core rotation for inter-calibration, an indirect method by using tokamak plasma itself has been applied on joint Texas experimental tokamak. It is found that the core toroidal rotation velocity is not zero during locked mode phase. This is consistent with the observation of small oscillations on soft x-ray signals and electron cyclotron emission during locked-mode phase.

  14. Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak.

    PubMed

    Yan, W; Chen, Z Y; Jin, W; Huang, D W; Ding, Y H; Li, J C; Zhang, X Q; Lee, S G; Shi, Y J; Zhuang, G

    2014-11-01

    The wavelength calibration of x-ray imaging crystal spectrometer is a key issue for the measurements of plasma rotation. For the lack of available standard radiation source near 3.95 Å and there is no other diagnostics to measure the core rotation for inter-calibration, an indirect method by using tokamak plasma itself has been applied on joint Texas experimental tokamak. It is found that the core toroidal rotation velocity is not zero during locked mode phase. This is consistent with the observation of small oscillations on soft x-ray signals and electron cyclotron emission during locked-mode phase.

  15. Energy calibration of a high-resolution inelastic x-ray scattering spectrometer

    SciTech Connect

    Verbeni, Roberto; D'Astuto, Matteo; Krisch, Michael; Lorenzen, Maren; Mermet, Alain; Monaco, Giulio; Requardt, Herwig; Sette, Francesco

    2008-08-15

    The energy scale of a triple-axis x-ray spectrometer with meV energy resolution based on perfect silicon crystal optics is calibrated, utilizing the most recent determination of the silicon lattice parameter and its thermal expansion coefficient and recording the dispersion of longitudinal acoustic and optical phonons in a diamond single crystal and the molecular vibration mode in liquid nitrogen. Comparison of the x-ray results with previous inelastic neutron and Raman scattering results as well as with ab initio phonon dispersion calculations yields an overall agreement better than 2%.

  16. A multiplexed high-resolution imaging spectrometer for resonant inelastic soft X-ray scattering spectroscopy.

    PubMed

    Warwick, Tony; Chuang, Yi De; Voronov, Dmitriy L; Padmore, Howard A

    2014-07-01

    The optical design of a two-dimensional imaging soft X-ray spectrometer is described. A monochromator will produce a dispersed spectrum in a narrow vertical illuminated stripe (∼2 µm wide by ∼2 mm tall) on a sample. The spectrometer will use inelastically scattered X-rays to image the extended field on the sample in the incident photon energy direction (vertical), resolving the incident photon energy. At the same time it will image and disperse the scattered photons in the orthogonal (horizontal) direction, resolving the scattered photon energy. The principal challenge is to design a system that images from the flat-field illumination of the sample to the flat field of the detector and to achieve sufficiently high spectral resolution. This spectrometer provides a completely parallel resonant inelastic X-ray scattering measurement at high spectral resolution (∼30,000) over the energy bandwidth (∼5 eV) of a soft X-ray absorption resonance.

  17. Determining x-ray spectra of radiographic sources with a Compton spectrometer

    NASA Astrophysics Data System (ADS)

    Gehring, Amanda E.; Espy, Michelle A.; Haines, Todd J.; Hunter, James F.; King, Nick S. P.; Manard, Manuel J.; Merrill, Frank E.; Morgan, George L.; Sedillo, Robert; Trainham, Rusty; Urbaitis, Algis V.; Volegov, Petr

    2014-09-01

    Flash radiography is a diagnostic with many physics applications, and the characterization of the energy spectra of such sources is of interest. A Compton spectrometer has been proposed to conduct these measurements. Our Compton spectrometer is a 300 kg neodymium-iron magnet constructed by Morgan et al1, and it is designed to measure spectra in the <1 MeV to 20 MeV range. In this device, the x-rays from a radiographic source are collimated into a narrow beam directed on a converter foil. The forward-selected Compton electrons that are ejected from the foil enter the magnetic field region of the spectrometer. The electrons are imaged on a focal plane, with their position determined as a function of their energy. The x-ray spectrum is then reconstructed. Challenges in obtaining these measurements include limited dose of x-rays and the short pulse duration (about 50 ns) for time-resolved measurements. Here we present energy calibration measurements of the spectrometer using a negative ion source. The resolution of the spectrometer was measured in previous calibration experiments to be the greater of 1% or 0.1 MeV/c1. The reconstruction of spectra from a bremsstrahlung source and Co-60 source are also presented.

  18. Measuring Curved Crystal Performance for a High Resolution, Imaging X-ray Spectrometer

    SciTech Connect

    Michael Haugh and Richard Stewart

    2010-06-07

    This paper describes the design, crystal selection, and crystal testing for a vertical Johann spectrometer operating in the 13 keV range to measure ion Doppler broadening in inertial confinement plasmas. The spectrometer is designed to use thin, curved, mica crystals to achieve a resolving power of E/ΔE>2000. A number of natural mica crystals were screened for flatness and X-ray diffraction width to find samples of sufficient perfection for use in the instrument. Procedures to select and mount high quality mica samples are discussed. A diode-type X-ray source coupled to a dual goniometer arrangement was used to measure the crystal reflectivity curve. A procedure was developed for evaluating the goniometer performance using a set of diffraction grade Si crystals. This goniometer system was invaluable for identifying the best original crystals for further use and developing the techniques to select satisfactory curved crystals for the spectrometer.

  19. Simulations of a Johann/Johansson diffraction spectrometer for x-ray experiments at an electron beam ion source

    NASA Astrophysics Data System (ADS)

    Jabłoński, Ł.; Jagodziński, P.; Banaś, D.; Pajek, M.

    2013-09-01

    The ray tracing simulations of x-ray spectra for a compact six-crystal Johann/Johansson diffraction spectrometer covering a wide photon energy range (70 eV-15 keV), i.e. from the extended ultraviolet to the hard x-ray region, are discussed in the context of x-ray experiments at an electron beam ion source facility. In particular, the x-ray line profiles and energy resolution for different diffraction crystals and multilayers were studied, and the effects of extension of x-ray source size and misalignment were investigated. The simulations were also performed for x-ray emission from solid targets bombarded by electrons, which will be used for calibration of the x-ray spectrometer.

  20. X-ray crystal spectrometer upgrade for ITER-like wall experiments at JET

    SciTech Connect

    Shumack, A. E.; Rzadkiewicz, J.; Chernyshova, M.; Czarski, T.; Karpinski, L.; Jakubowska, K.; Scholz, M.; Byszuk, A.; Cieszewski, R.; Kasprowicz, G.; Pozniak, K.; Wojenski, A.; Zabolotny, W.; Dominik, W.; Conway, N. J.; Dalley, S.; Tyrrell, S.; Zastrow, K.-D.; Figueiredo, J. [EFDA-CSU, Culham Science Centre, Abingdon OX14 3DB; Associação EURATOM and others

    2014-11-15

    The high resolution X-Ray crystal spectrometer at the JET tokamak has been upgraded with the main goal of measuring the tungsten impurity concentration. This is important for understanding impurity accumulation in the plasma after installation of the JET ITER-like wall (main chamber: Be, divertor: W). This contribution provides details of the upgraded spectrometer with a focus on the aspects important for spectral analysis and plasma parameter calculation. In particular, we describe the determination of the spectrometer sensitivity: important for impurity concentration determination.

  1. X-ray crystal spectrometer upgrade for ITER-like wall experiments at JET.

    PubMed

    Shumack, A E; Rzadkiewicz, J; Chernyshova, M; Jakubowska, K; Scholz, M; Byszuk, A; Cieszewski, R; Czarski, T; Dominik, W; Karpinski, L; Kasprowicz, G; Pozniak, K; Wojenski, A; Zabolotny, W; Conway, N J; Dalley, S; Figueiredo, J; Nakano, T; Tyrrell, S; Zastrow, K-D; Zoita, V

    2014-11-01

    The high resolution X-Ray crystal spectrometer at the JET tokamak has been upgraded with the main goal of measuring the tungsten impurity concentration. This is important for understanding impurity accumulation in the plasma after installation of the JET ITER-like wall (main chamber: Be, divertor: W). This contribution provides details of the upgraded spectrometer with a focus on the aspects important for spectral analysis and plasma parameter calculation. In particular, we describe the determination of the spectrometer sensitivity: important for impurity concentration determination.

  2. A multi-cone x-ray imaging Bragg crystal spectrometer

    NASA Astrophysics Data System (ADS)

    Bitter, M.; Hill, K. W.; Gao, Lan; Efthimion, P. C.; Delgado-Apariccio, L.; Lazerson, S.; Pablant, N.

    2016-11-01

    This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. These unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.

  3. SolpeX: the soft X-ray flare polarimeter-spectrometer for the ISS

    NASA Astrophysics Data System (ADS)

    Sylwester, Janusz; Płocieniak, Stefan; Bakała, Jarosław; Szaforz, Żaneta; Stȩślicki, Marek; Ścisłowski, Daniel; Kowaliński, Mirosław; Podgórski, Piotr; Hernandez, Jose; Shestov, Sergey

    2015-10-01

    We present the innovative soft X-ray spectro-polarimeter, SolpeX. This instrument consists of three functionally independent blocks. They are to be included into the Russian instrument KORTES, to be mounted onboard the ISS. The three SolpeX units are: a simple pin-hole X-ray spectral imager, a polarimeter, and a fast-rotating drum multiple-flat-crystal Bragg spectrometer. Such a combination of measuring blocks will offer a new opportunity to reliably measure possible X-ray polarization and spectra of solar flares, in particular during the impulsive phase. Polarized Bremsstrahlung and line emission due to the presence of directed particle beams will be detected, and measurements of the velocities of evaporated hot plasma will be made. In this paper we discuss the details of the construction of the SolpeX units. The delivery of KORTES with SolpeX to the ISS is expected to happen in 2017/2018.

  4. Imaging x-ray Thomson scattering spectrometer design and demonstration (invited).

    PubMed

    Gamboa, E J; Huntington, C M; Trantham, M R; Keiter, P A; Drake, R P; Montgomery, D S; Benage, J F; Letzring, S A

    2012-10-01

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  5. Imaging x-ray Thomson scattering spectrometer design and demonstration (invited)a)

    NASA Astrophysics Data System (ADS)

    Gamboa, E. J.; Huntington, C. M.; Trantham, M. R.; Keiter, P. A.; Drake, R. P.; Montgomery, D. S.; Benage, J. F.; Letzring, S. A.

    2012-10-01

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  6. Development of high resolution x-ray spectrometers for the investigation of bioinorganic chemistry in metalloproteins

    NASA Astrophysics Data System (ADS)

    Drury, Owen Byron

    We have built an X-ray spectrometer for synchrotron-based high-resolution soft X-ray spectroscopy. The spectrometer uses four 9-pixel arrays of superconducting tunnel junctions (STJs) as sensors. They infer the energy of an absorbed X-ray from a temporary increase in tunneling current. The STJs are operated in a two-stage adiabatic demagnetization refrigerator (ADR) that uses liquid nitrogen and helium for precooling to 77 K and 4.2 K, and gallium gadolinium garnet and iron ammonium sulfate to attain a base temperature below 0.1 K. The sensors are held at the end of a 40-cm-long cold finger within ˜1 cm of a sample located inside the vacuum chamber of a synchrotron beam line end station. The spectrometer has an energy resolution between 10 eV and 20 eV FWHM below 1 keV, can be operated at rates up to ˜106 counts/s. STJ spectrometers are suited for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS) in cases where conventional germanium detectors do not have enough energy resolution. We have used this STJ spectrometer at the Advanced Light Source synchrotron for spectroscopy on the lower energy X-ray absorption edges of the elements Mo, S, Fe and N. These elements play an important role in biological nitrogen fixation at the metalloprotein nitrogenase, and we have examined if STJ spectrometers can be used to provide new insights into some of the open questions regarding the reaction mechanism of this protein. We have taken X-ray absorption near-edge spectra (XANES) and extended fine structure spectra (EXAFS) of an Fe 6N(CO)15-compound containing a single N atom inside a cluster of six Fe atoms, as postulated to exist inside the Fe-S cluster of the FeMo-cofactor (FeMo-co) in nitrogenase. The STJ detector has enabled the first-ever extended range EXAFS scans on nitrogen through the oxygen K-edge, enabling a comparison with N EXAFS on FeMo-co. We have taken iron L23-edge spectra of the Fe-S cluster in FeMo-co, which can be

  7. A controlled dispersion parallel wavelength x ray spectrometer for electron microscopy

    NASA Astrophysics Data System (ADS)

    Fiori, C. E.; Wight, S. A.; Romig, A. D., Jr.

    1991-04-01

    A new technique is described for the detection of x rays in electron column instruments used in microanalysis. In electron column instruments, the point source of x rays is produced by the interaction of a focused electron beam with the sample. Neither of the conventional methods, wavelength dispersive (WDS) nor energy dispersive (EDS) based spectrometry, is optimized for low Z element quantitative analysis. In WDS applications, where the analyte elements are Be through P, chemical effects complicate the x ray measurement process. Peak positions and shapes are altered, sometimes very strongly, by the electron configurations of the analyte atoms and neighboring atoms. In these cases, the ideal spectrometer would profile the peak and some small amount of continuum on either side of the peak such that an accurate peak area could be calculated. Present WDS spectrometers are serial in nature and cannot directly measure peak areas, often causing errors in the determination of light element concentrations. Bastin and co-workers have developed an elegant method to provide accurate area determinations, using the serial spectrometer, by a three point procedure. The parallel wavelength dispersive spectrometer (PWDS) proposed here is ideally suited for those applications.

  8. Wavelength dispersing devices for soft and ultrasoft x-ray spectrometers

    SciTech Connect

    Arai, Tomoya; Ryon, R.W.; Shoji, Takashi

    1984-01-01

    Monochromatization combining total reflection by a selected mirror and an appropriate filter offered an alternative approach in order to increase measurable intensity with reasonable spectral resolution. Recently, the use of synthetic multilayers, which are prepared by sputter/evaporation techniques, has been introduced for the detection of soft and ultrasoft x-rays. Studies on the use of these new wavelength dispersing devices have been conducted and it has been found that the reflectivity of these devices is very high compared with single crystals and soap multilayers and that their resolving power is fairly good. This report makes comparisons regarding efficiency of reflection, resolving power and x-ray analytical problems for practical applications among long spacing single crystals, soap multilayers, total reflection combined with a selected mirror and filtering and synthetic multilayers. The x-ray analytical capablities are shown based upon a standard x-ray fluorescence spectrometer equipped with a sealed-off x-ray tube and a gas flow proportional counter with thin film detector window.

  9. Results of the Alpha-Particle-X-Ray Spectrometer on Board of the Mars Exploration Rovers

    NASA Technical Reports Server (NTRS)

    Geller, R.; Zipfel, J.; Brueckner, J.; Dreibus, G.; Lugmair, G.; Rieder, R.; Waenke, H.; Klingelhoefer, G.; Clark, B. C.; Ming, D. W.

    2005-01-01

    The Mars Exploration Rovers Spirit and Opportunity landed at Gusev crater and Meridiani Planum. The Alpha Particle X-ray Spectrometer (APXS) is part of the instrument suite on both rovers. It is equipped with six 244Cm sources which provide x-ray excitation with alpha-particles (PIXE) and x-ray radiation (XRF). This combination allows x-ray spectroscopy of elements from Na to Br in the energy range of 0.9 to 16 keV. X-ray detectors with a high energy resolution of 160 eV at Fe K allow us to separate even closely spaced energy peaks, such as Na, Mg, Al and Si. The APXS is attached to the rover s arm and provides in-situ measurements of the chemical composition of soils, surfaces of rocks and outcrops and their abraded surfaces. This abstract gives an overview of APXS results obtained during the first year of operation on both landing sites.

  10. Designing the X-Ray Microcalorimeter Spectrometer for Optimal Science Return

    NASA Technical Reports Server (NTRS)

    Ptak, Andrew; Bandler, Simon R.; Bookbinder, Jay; Kelley, Richard L.; Petre, Robert; Smith, Randall K.; Smith, Stephen

    2013-01-01

    Recent advances in X-ray microcalorimeters enable a wide range of possible focal plane designs for the X-ray Microcalorimeter Spectrometer (XMS) instrument on the future Advanced X-ray Spectroscopic Imaging Observatory (AXSIO) or X-ray Astrophysics Probe (XAP). Small pixel designs (75 microns) oversample a 5-10" PSF by a factor of 3-6 for a 10 m focal length, enabling observations at both high count rates and high energy resolution. Pixel designs utilizing multiple absorbers attached to single transition-edge sensors can extend the focal plane to cover a significantly larger field of view, albeit at a cost in maximum count rate and energy resolution. Optimizing the science return for a given cost and/or complexity is therefore a non-trivial calculation that includes consideration of issues such as the mission science drivers, likely targets, mirror size, and observing efficiency. We present a range of possible designs taking these factors into account and their impacts on the science return of future large effective-area X-ray spectroscopic missions.

  11. Highly efficient beamline and spectrometer for inelastic soft X-ray scattering at high resolution.

    PubMed

    Lai, C H; Fung, H S; Wu, W B; Huang, H Y; Fu, H W; Lin, S W; Huang, S W; Chiu, C C; Wang, D J; Huang, L J; Tseng, T C; Chung, S C; Chen, C T; Huang, D J

    2014-03-01

    The design, construction and commissioning of a beamline and spectrometer for inelastic soft X-ray scattering at high resolution in a highly efficient system are presented. Based on the energy-compensation principle of grating dispersion, the design of the monochromator-spectrometer system greatly enhances the efficiency of measurement of inelastic soft X-rays scattering. Comprising two bendable gratings, the set-up effectively diminishes the defocus and coma aberrations. At commissioning, this system showed results of spin-flip, d-d and charge-transfer excitations of NiO. These results are consistent with published results but exhibit improved spectral resolution and increased efficiency of measurement. The best energy resolution of the set-up in terms of full width at half-maximum is 108 meV at an incident photon energy tuned about the Ni L3-edge.

  12. Design and operation of a hard x-ray transmissive single-shot spectrometer at LCLS

    NASA Astrophysics Data System (ADS)

    Zhu, D.; Cammarata, M.; Feldkamp, J.; Fritz, D. M.; Hastings, J.; Lee, S.; Lemke, H. T.; Robert, A.; Turner, J.; Feng, Y.

    2013-03-01

    We describe the design and operation of a transmissive single-shot spectrometer for the measurement of hard x-ray free electron laser (FEL) source spectrum at the Linac Coherent Light Source (LCLS). The spectrometer was built around a 10 μm thick near-perfect silicon single crystal that was cylindrically bent. Its energy range covered the full FEL bandwidth while its resolution was sufficient for resolving single spectral spikes characteristics of the FELs. Its application will not only greatly facilitate the understanding and optimization of the x-ray FEL sources, but can also serve as an invaluable inline diagnostic tool for experiments where the spectral content of the source plays an important role in data interpretation.

  13. X-ray rocking curve measurements of bent crystals. [used in High Resolution Spectrometer in Advanced X-ray Astrophysics Facility

    NASA Technical Reports Server (NTRS)

    Hakim, M. B.; Muney, W. S.; Fowler, W. B.; Woodgate, B. E.

    1988-01-01

    A three-crystal laboratory X-ray spectrometer is used to measure the Bragg reflection from concave cylindrically curved crystals to be used in the high-resolution X-ray spectrometer of the NASA Advanced X-ray Astrophysics Facility (AXAF). The first two crystals, in the dispersive (1.1) arrangement, select a narrow collimated monochromatic beam in the Cu K-alpha(1) line at 1.5 A (8.1 keV), which illuminates the test crystal. The angular centroids of rocking curves measured along the surface provide a measure of the conformity of the crystal to the desired radius of curvature. Individual and combined rocking-curve widths and areas provide a measure of the resolution and efficiency at 1.54 A. The crystals analyzed included LiF(200), PET, and acid phthalates such as TAP.

  14. On the characterisation of a Bragg spectrometer with X-rays from an ECR source

    NASA Astrophysics Data System (ADS)

    Anagnostopoulos, D. F.; Biri, S.; Gotta, D.; Gruber, A.; Indelicato, P.; Leoni, B.; Fuhrmann, H.; Simons, L. M.; Stingelin, L.; Wasser, A.; Zmeskal, J.

    2005-06-01

    Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (1 1 1) or quartz (1 0 1¯) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and the geometry of the experimental set-up.

  15. The first experimental results from x-ray imaging crystal spectrometer for KSTAR

    SciTech Connect

    Lee, S. G.; Bak, J. G.; Nam, U. W.; Moon, M. K.; Shi, Y.; Bitter, M.; Hill, K.

    2010-10-15

    The x-ray imaging crystal spectrometer (XICS) for the Korea Superconducting Tokamak Advanced Research has been first applied for the experimental campaign in 2009. The XICS was designed to provide measurements of the profiles of the ion and electron temperatures from the heliumlike argon (Ar XVII) spectra. The basic functions of the XICS are properly working although some satellites lines are not well matched with the expected theoretical values. The initial experimental results from the XICS are briefly described.

  16. Use of mercuric iodide x-ray detectors with alpha backscattering spectrometers for space applications

    SciTech Connect

    Iwanczyk, J.S.; Wang, Y.J.; Dorri, N.; Dabrowski, A.J. ); Economou, T.E.; Turkevich, A.L. . Enrico Fermi Inst.)

    1991-04-01

    This paper presents x-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI{sub 2}) spectrometer inserted into an Alpha Backscattering Instrument identical to that used in the Soviet Phobos Mission. The results obtained with the HgI{sub 2} ambient temperature detector are compared with those obtained using a Si(Li) cryogenically cooled detector. The authors' efforts to design an optimized instrument for space application are described.

  17. Laboratory studies on a spherically curved Bragg spectrometer for cosmic X-ray spectroscopy

    NASA Technical Reports Server (NTRS)

    Cantin, M.; Koch-Miramond, L.; Mougin, B.; Rocchia, R.

    1981-01-01

    A spherical array of twenty LiF 200 crystals was built to test the performances of a freestanding, self-focussing spherical crystal cosmic X-ray spectrometer. Measurements presently available show that the size of the image for a point source at infinite distance would be 3 mm (FWHM) along the focalisation axis and 2.1 mm (FWHM) along the dispersion axis. The mosaic spread on individual crystals is less than 0.1 degree. A slightly systematic deviation from the ideal bending (0.1 degree) is observed at the edges of most crystals and this appears to be the major limitation to spectrometer performance.

  18. APEX/J-PEX: A High-Resolution Spectrometer for EUV/X-ray Wavelengths

    NASA Astrophysics Data System (ADS)

    Kowalski, M. P.; Cruddace, R. G.; Gursky, H.; Yentis, D. J.

    2001-09-01

    Future X-ray and EUV missions should include high-resolution spectrometers, permitting use of the full range of spectroscopic diagnostics, in particular measurement of line profiles and Doppler shifts. We present a design for such an instrument (APEX), which would fly on a Small Explorer Satellite and which employs multilayer-coated ion-etched gratings in a normal-incidence configuration. We have already flown successfully a prototype spectrometer (J-PEX) on a NASA sounding rocket. The resulting EUV spectrum of the white dwarf G191-B2B will be presented.

  19. Future Development Trajectories for Imaging X-rays Spectrometers Based on Microcalorimeters

    NASA Technical Reports Server (NTRS)

    Kilbourne, Caroline A.; Bandler, Simon R.

    2013-01-01

    Future development trajectories for imaging x-ray spectrometers based on microcalorimeters. Since their invention 30 years ago, the capability of X-ray microcalorimeters has increased steadily, with continual improvements in energy resolution, speed, and array size. Arrays of up to 1024 pixels have been produced, and resolution better than 1 eV at 1.5 keV has been achieved. These detectors can be optimized for the highest priority science, such as designing for the highest resolving power at low energies at the expense of dynamic range, or the greatest focal-plane coverage at the expense of speed. Three types of X-ray microcalorimeters presently dominate the field, each characterized by the thermometer technology. The first two types use temperature-sensitive resistors: semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a magnetically coupled thermometer, and is at an earlier stage of development than the other two. The Soft X-ray Spectrometer (SXS) on Astro-H, expected to launch in 2015, will use an array of silicon thermistors with HgTe X-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays. Kilopixel arrays of the superconducting calorimeters are being produced, and much larger arrays may require the non-dissipative advantage of magnetically coupled thermometers. I will project the development trajectories of these detectors and their read-out technologies and assess what their capabilities and limitations will be 10 - 20 years from now.

  20. Energy resolution and high count rate performance of superconducting tunnel junction x-ray spectrometers

    NASA Astrophysics Data System (ADS)

    Frank, M.; Hiller, L. J.; le Grand, J. B.; Mears, C. A.; Labov, S. E.; Lindeman, M. A.; Netel, H.; Chow, D.; Barfknecht, A. T.

    1998-01-01

    We present experimental results obtained with a cryogenically cooled, high-resolution x-ray spectrometer based on a 141 μm×141 μm Nb-Al-Al2O3-Al-Nb superconducting tunnel junction (STJ) detector in a demonstration experiment. Using monochromatized synchrotron radiation we studied the energy resolution of this energy-dispersive spectrometer for soft x rays with energies between 70 and 700 eV and investigated its performance at count rates up to nearly 60 000 cps. At count rates of several 100 cps we achieved an energy resolution of 5.9 eV (FWHM) and an electronic noise of 4.5 eV for 277 eV x rays (the energy corresponding to C K). Increasing the count rate, the resolution 277 eV remained below 10 eV for count rates up to ˜10 000 cps and then degraded to 13 eV at 23 000 cps and 20 eV at 50 000 cps. These results were achieved using a commercially available spectroscopy amplifier with a baseline restorer. No pile-up rejection was applied in these measurements. Our results show that STJ detectors can operate at count rates approaching those of semiconductor detectors while still providing a significantly better energy resolution for soft x rays. Thus STJ detectors may prove very useful in microanalysis, synchrotron x-ray fluorescence (XRF) applications, and XRF analysis of light elements (K lines) and transition elements (L lines).

  1. High energy resolution x-ray spectrometer for high count rate XRF applications

    SciTech Connect

    Rossington, C.S.; Madden, N.W.; Chapman, K.

    1993-08-01

    A new x-ray spectrometer has been constructed which incorporates a novel large area, low capacitance Si(Li) detector and a low noise JFET (junction field effect transistor) pr- eamplifier. The spectrometer operates at high count rates without the conventional compromise in energy resolution. For example, at an amplifier peaking time of 1 {mu}sec and a throughput count rate of 145,000 counts sec{sup {minus}1}, the energy resolution at 5.9 key is 220 eV FWHM. Commercially available spectrometers utilizing conventional geometry Si(Li) detectors with areas equivalent to the new detector have resolutions on the order of 540 eV under the same conditions. Conventional x-ray spectrometers offering high energy resolution must employ detectors with areas one-tenth the size of the new LBL detector (20 mm{sup 2} compared with 200 mm{sup 2}). However, even with the use of the smaller area detectors, the energy resolution of a commercial system is typically limited to approximately 300 eV (again, at 1 {mu}sec and 5.9 keV) due to the noise of the commercially available JFET`S. The new large area detector is useful in high count rate applications, but is also useful in the detection of weak photon signals, in which it is desirable to subtend as large an angle of the available photon flux as possible, while still maintaining excellent energy resolution. X-ray fluorescence data from the new spectrometer is shown in comparison to a commercially available system in the analysis of a dilute multi-element material, and also in conjunction with high count rate synchrotron EXAMS applications.

  2. Modeling the expected performance of the REgolith X-ray Imaging Spectrometer (REXIS)

    NASA Astrophysics Data System (ADS)

    Inamdar, Niraj K.; Binzel, Richard P.; Hong, Jae Sub; Allen, Branden; Grindlay, Jonathan; Masterson, Rebecca A.

    2014-09-01

    OSIRIS-REx is the third spacecraft in the NASA New Frontiers Program and is planned for launch in 2016. OSIRIS-REx will orbit the near-Earth asteroid (101955) Bennu, characterize it, and return a sample of the asteroid's regolith back to Earth. The Regolith X-ray Imaging Spectrometer (REXIS) is an instrument on OSIRIS-REx designed and built by students at MIT and Harvard. The purpose of REXIS is to collect and image sun-induced fluorescent X-rays emitted by Bennu, thereby providing spectroscopic information related to the elemental makeup of the asteroid regolith and the distribution of features over its surface. Telescopic reflectance spectra suggest a CI or CM chondrite analog meteorite class for Bennu, where this primitive nature strongly motivates its study. A number of factors, however, will influence the generation, measurement, and interpretation of the X-ray spectra measured by REXIS. These include: the compositional nature and heterogeneity of Bennu, the time-variable solar state, X-ray detector characteristics, and geometric parameters for the observations. In this paper, we will explore how these variables influence the precision to which REXIS can measure Bennu's surface composition. By modeling the aforementioned factors, we place bounds on the expected performance of REXIS and its ability to ultimately place Bennu in an analog meteorite class.

  3. Handheld X-ray Fluorescence Spectrometers: Radiation Exposure Risks of Matrix-Specific Measurement Scenarios.

    PubMed

    Rouillon, Marek; Kristensen, Louise J; Gore, Damian B

    2015-07-01

    This study investigates X-ray intensity and dispersion around handheld X-ray fluorescence (XRF) instruments during the measurement of a range of sample matrices to establish radiation exposure risk during operation. Four handheld XRF instruments representing three manufacturers were used on four smooth, flat-lying materials of contrasting matrix composition. Dose rates were measured at 10, 20, 30, and 40 cm intervals every 30° around the instrument at 0 and 45° from the horizontal, as well as vertically from the instrument screen. The analysis of polyethylene recorded dose rates 156 times higher (on average) than steel measurements and 34 times higher than both quartz sand and quartz sandstone. A worst-case exposure scenario was assumed where a user analyses a polyethylene material at arms reach for 1 h each working day for one year. This scenario resulted in an effective body dose of 73.5 μSv, equivalent to three to four chest X-rays (20 μSv) a year, 20 times lower than the average annual background radiation exposure in Australia and well below the annual exposure limit of 1 mSv for non-radiation workers. This study finds the advantages of using handheld XRF spectrometers far outweighs the risk of low radiation exposure linked to X-ray scattering from samples. PMID:26037330

  4. Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST

    NASA Astrophysics Data System (ADS)

    Lu, Bo; Shi, Yuejiang; Wang, Fudi; Wan, Baonian; Manfred, Bitter; Kenneth, W. Hill; Sang-gon, Lee; Li, Yingying; Fu, Jia; Zhang, Jizong; Xu, Jingcui; Shen, Yongcai

    2013-02-01

    An attempt was made to improve the spatio-temporal resolution of the tangential X-ray crystal spectrometer (XCS) on the Experimental Advanced Superconducting Tokamak (EAST) by evaluating experimentally the applicability of a novel X-ray photon detection technology for measuring the satellite spectra of Ar XVII with a high counting rate. High-resolution experimental data on the profiles of ion temperature and plasma rotation velocity facilitate the studies of the mechanisms underlining important physical phenomena, such as plasma heating, L-H transition and momentum transport. Based on silicon diode array and single-photon counting technology, a relatively small area (83.8×33.5 mm2) two-dimensional detector was successfully installed and tested in the recent EAST campaign. X-ray photon counting rate higher than 20 MHz was observed for the first time, and high quality satellite spectra were recorded for ion temperature and plasma rotation measurement, indicating that the new technology is suitable for the next-step high-resolution XCS on EAST, and the deployment of a detector array with a much larger X-ray sensing area is planned for better plasma coverage.

  5. The High-Resolution X-Ray Microcalorimeter Spectrometer, SXS, on Astro-H

    NASA Technical Reports Server (NTRS)

    Mitsuda, Kazuhisa; Kelley, Richard L.; Boyce, Kevin R.; Brown, Gregory V.; Costantini, Elisa; DiPirro, Michael J.; Ezoe, Yuichiro; Fujimoto, Ryuichi; Gendreau, Keith C.; denHerder, Jan-Willem; Hoshino, Akio; Ishisaki, Yoshitaka; Kilbourne, Caroline A.; Kitamoto, Shunji; McCammon, Dan; Murakami, Masahide; Murakami, Hiroshi; Ogawa, Mina; Ohashi, Takaya; Okamoto, Atsushi; Paltani, Stephane; Pohl, Martin; Porter, F. Scott; Sato, Yoichi; Shinozaki, Keisuke

    2012-01-01

    The science and an overview of the Soft X-ray Spectrometer onboard the STRO-H mission are presented. The SXS consists of X-ray focusing mirrors and a microcalorimeter array and is developed by international collaboration lead by JAXA and NASA with European participation. The detector is a 6 x 6 format microcalorimeter array operated at a cryogenic temperature of 50 mK and covers a 3' x 3' field of view of the X-ray telescope of 5.6 m focal length. We expect an energy resolution better than 7 eV (FWHM, requirement) with a goal of 4 eV. The effective area of the instrument will be 225 square centimeters at 7 keV; by a factor of about two larger than that of the X-ray microcalorimeter on board Suzaku. One of the main scientific objectives of the SXS is to investigate turbulent and/or macroscopic motions of hot gas in clusters of galaxies.

  6. The spectrometer telescope for imaging X-rays (STIX) on board Solar Orbiter

    NASA Astrophysics Data System (ADS)

    Vilmer, Nicole; Krucker, Samuel; Karol Seweryn, D..; Orleanski, Piotr; Limousin, Olivier; Meuris, Aline; Brun, Allan Sacha; Grimm, Oliver; Groebelbauer, HansPeter; Rendtel, J.

    The Spectrometer Telescope for Imaging X-rays (STIX) is one of 10 instruments on board Solar Orbiter, a confirmed M-class mission of the European Space Agency (ESA) within the Cosmic Vision program scheduled to be launched in 2017. STIX applies a Fourier-imaging technique using a set of tungsten grids (at pitches from 0.038 to 1 mm) in front of 32 pixelized CdTe detectors to provide imaging spectroscopy of solar thermal and non-thermal hard X-ray emissions from 4 to 150 keV. The paper presents the status of the instrument for the Critical Design Review to be held with ESA in June 2014. Particular emphasis is given to the CdTe hybrid detector called Caliste-SO for high resolution hard X-ray spectroscopy from 4 to 150 keV: Characterizations of the first production batch are reported. Caliste-SO spectrometer units could also fulfill the needs for the SORENTO instrument of the Russian Interhelioprobe mission currently in assessment study.

  7. 2 Dimensional position sensitive XAFS by using in-house X-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Shinoda, Kozo; Suzuki, Shigeru; Kuribayashi, Masaru; Taguchi, Takeyoshi

    2009-09-01

    Position sensitive XAFS measurements by using the in-house X-ray spectrometer and the position sensitive X-ray detector were attempted. The in-house spectrometer produces monochromized divergent X-ray beam. Therefore, an extended direct-beam image projected on the detector can be taken, and its extension rate is depending on the arrangement of the sample and the detector. A position sensitive XAFS measurement was demonstrated by using Ni metal foil and NiO powder as a model sample. Ge(220) or Si(400) Johansson-type bent single-crystal was used as monochromator, and Mo and LaB6 were used as the target and filament, respectively. Tube voltage and current were operated at 16 kV and 100 mA (1.6 kW). XAFS spectra were measured by transmission-mode with sample set/reset method and required time of each experiment is about 6 hours in total. It was confirmed that metal and oxide spectra with enough quality for structural analysis were clearly separated by each position in the sample.

  8. Design Study of an X-ray Crystal Spectrometer for the HANBIT Mirror Machine

    NASA Astrophysics Data System (ADS)

    Lee, S. G.; Hwang, S. M.; Bitter, M. L.

    1997-11-01

    X-ray crystal spectroscopy is expected to play a major role for the diagnostics of the reactor-like plasmas produced in future large tokamaks, such as KSTAR and ITER. However, it is also desirable to extend the observable spectral range to longer wavelengths (7-15 dotA), which is of interest for the diagnostics of plasmas with much lower electron densities (10^11-10^12 cm-3) and electron temperatures (100 - 200 eV) in other magnetic-confinement experiments, such as the HANBIT mirror machine. The construction of crystal spectrometers for this wavelength range and these plasma conditions is challenging because of the low X-ray emissivity and the fact that the low-energy X-rays are strongly attenuated by even very thin foils or windows. New types of detectors other than the presently used multi-wire proportional counters are therefore needed to obtain a high detection efficiency. In this paper, we present a design study for a vacuum spectrometer with a CCD array detector and detailed estimates of the instrument performance for the observation of spectra from O, Ne and Al ions.

  9. Imaging X-ray crystal spectrometer for laser-produced plasmas

    NASA Astrophysics Data System (ADS)

    Gamboa, E. J.; Montgomery, D. S.; Hall, I. M.; Drake, R. P.

    2011-04-01

    X-ray Thomson scattering (XRTS) is a powerful technique for measuring state variables in dense plasmas. In this paper, we report on the development of a one-dimensional imaging spectrometer for use in characterizing spatially nonuniform, dense plasmas using XRTS. Diffraction of scattered x-rays from a toroidally curved crystal images along a one-dimensional spatial profile while simultaneously spectrally resolving along the other. An imaging spectrometer was fielded at the Trident laser at Los Alamos National Laboratory, yielding a FWHM spatial resolution of < 25 μm, spectral resolution of 4 eV, spectral range of 350 eV, and spatial range of > 3 mm. A geometrical analysis is performed yielding a simple analytical expression for the throughput of the imaging spectrometer scheme. The SHADOW code is used to perform a ray tracing analysis on the spectrometer fielded at the Trident Laser Facility understand the alignment tolerances on the spatial and spectral resolutions. The analytical expression for the throughput was found to agree well with the results from the ray tracing.

  10. ComIXS on BACH: a compact soft x-ray spectrometer operating at Elettra

    SciTech Connect

    Cocco, Daniele; Matteucci, Maurizio; Zangrando, Marco; Bondino, Federica; Zacchigna, Michele; Plate, Mauro; Parmigiani, Fulvio; Nelles, Bruno; Prince, Kevin C.

    2004-05-12

    To accommodate increasing interest in soft x-ray inelastic scattering, a new spectrometer has been designed, constructed and commissioned at Elettra. This instrument uses as the dispersive element one of two interchangeable Variable Line Spacing (VLS) spherical gratings. The energy scan is performed by a 7 cm linear translation of a back illuminated CCD which also collects the zero order light, facilitating alignment and calibration. The two gratings have the same radius of curvature while the groove densities and the groove density variations differ by a factor four. Thus the energies focused by the gratings at a particular position differ by a factor of four. The total length of the instrument is 60 cm, the energy range covered is roughly 25-1000 eV and the expected resolving power ranges from 1000 to 5000. The spectrometer is now operating on the beamline Bach. It takes advantage of the small size of the photon spot in the experimental chamber and of the possibility to control the polarization of the incoming radiation. The small spot constitutes the virtual entrance slit, and the spectrometer collects the photons emitted in a solid angle of about 30x10 mrad2. The instrument, named ComIXS (Compact Inelastic X-ray Spectrometer), has been routinely operating since October 2002. Several experiments have already been carried out, and some results illustrating the characteristics of the instrument are described. The manufacture and testing of the blaze gratings are also discussed.

  11. ComIXS on BACH: a compact soft x-ray spectrometer operating at Elettra

    NASA Astrophysics Data System (ADS)

    Cocco, Daniele; Zangrando, Marco; Matteucci, Maurizio; Bondino, Federica; Platè, Mauro; Zacchigna, Michele; Parmigiani, Fulvio; Nelles, Bruno; Prince, Kevin C.

    2004-05-01

    To accommodate increasing interest in soft x-ray inelastic scattering, a new spectrometer has been designed, constructed and commissioned at Elettra. This instrument uses as the dispersive element one of two interchangeable Variable Line Spacing (VLS) spherical gratings. The energy scan is performed by a 7 cm linear translation of a back illuminated CCD which also collects the zero order light, facilitating alignment and calibration. The two gratings have the same radius of curvature while the groove densities and the groove density variations differ by a factor four. Thus the energies focused by the gratings at a particular position differ by a factor of four. The total length of the instrument is 60 cm, the energy range covered is roughly 25-1000 eV and the expected resolving power ranges from 1000 to 5000. The spectrometer is now operating on the beamline Bach. It takes advantage of the small size of the photon spot in the experimental chamber and of the possibility to control the polarization of the incoming radiation. The small spot constitutes the virtual entrance slit, and the spectrometer collects the photons emitted in a solid angle of about 30×10 mrad2. The instrument, named ComIXS (Compact Inelastic X-ray Spectrometer), has been routinely operating since October 2002. Several experiments have already been carried out, and some results illustrating the characteristics of the instrument are described. The manufacture and testing of the blaze gratings are also discussed.

  12. Is Asteroid 433 Eros Compositionally Homogeneous? New Analyses of NEAR-Shoemaker X-Ray Spectrometer Data

    NASA Technical Reports Server (NTRS)

    Nittler, L. R.; Trombka, J. I.

    2001-01-01

    We present new analysis techniques for NEAR-Shomaker X-ray spectrometer data to infer the compositional heterogeneity of asteroid 433 Eros. Preliminary results indicate a largely chondritic, homogeneous composition. Additional information is contained in the original extended abstract.

  13. X-Ray Reprocessing in Active Galactic Nuclei

    NASA Technical Reports Server (NTRS)

    Begelman, Mitchell C.

    2004-01-01

    This is the final report for research entitled "X-ray reprocessing in active galactic nuclei," into X-ray absorption and emission in various classes of active galaxy via X-ray spectral signatures. The fundamental goal of the research was to use these signatures as probes of the central engine structure and circumnuclear environment of active galactic nuclei. The most important accomplishment supported by this grant involved the detailed analysis and interpretation of the XMM data for the bright Seyfert 1 galaxy MCG-6-30-15. This work was performed by Drs. Christopher Reynolds and Mitchell Begelman in collaboration with Dr. Jorn Wilms (University of Tubingen, Germany; PI of the XMM observation) and other European scientists. With XMM we obtained medium resolution X-ray spectra of unprecedented quality for this Seyfert galaxy. Modeling the X-ray spectrum within the framework of accretion disk reflection models produced the first evidence for energy extraction from the spin of a black hole. Specifically, we found that the extreme gravitational redshifts required to explain the X-ray spectrum suggests that the bulk of the energy dissipation is concentrated very close to the black hole, in contrast with the expectations of any pure accretion disk model. In a second paper we addressed the low- energy spectral complexity and used RXTE specta to pin down the high-energy spectral index, thus firming up our initial interpretation. Additionally, we carried out detailed spectral and variability analyses of a number of Seyfert and radio galaxies (e.g., NGC 5548 and 3C 111) and developed general techniques that will be useful in performing X-ray reverberation mapping of accretion disks in AGN, once adequate data becomes available. A list of papers supported by this research is included.

  14. The spectrometer telescope for imaging x-rays on board the Solar Orbiter mission

    NASA Astrophysics Data System (ADS)

    Benz, A. O.; Krucker, S.; Hurford, G. J.; Arnold, N. G.; Orleanski, P.; Gröbelbauer, H.-P.; Klober, S.; Iseli, L.; Wiehl, H. J.; Csillaghy, A.; Etesi, L.; Hochmuth, N.; Battaglia, M.; Bednarzik, M.; Resanovic, R.; Grimm, O.; Viertel, G.; Commichau, V.; Meuris, A.; Limousin, O.; Brun, S.; Vilmer, N.; Skup, K. R.; Graczyk, R.; Stolarski, M.; Michalska, M.; Nowosielski, W.; Cichocki, A.; Mosdorf, M.; Seweryn, K.; Przepiórka, A.; Sylwester, J.; Kowalinski, M.; Mrozek, T.; Podgorski, P.; Mann, G.; Aurass, H.; Popow, E.; Onel, H.; Dionies, F.; Bauer, S.; Rendtel, J.; Warmuth, A.; Woche, M.; Plüschke, D.; Bittner, W.; Paschke, J.; Wolker, D.; Van Beek, H. F.; Farnik, F.; Kasparova, J.; Veronig, A. M.; Kienreich, I. W.; Gallagher, P. T.; Bloomfield, D. S.; Piana, M.; Massone, A. M.; Dennis, B. R.; Schwarz, R. A.; Lin, R. P.

    2012-09-01

    The Spectrometer Telescope for Imaging X-rays (STIX) is one of 10 instruments on board Solar Orbiter, a confirmed Mclass mission of the European Space Agency (ESA) within the Cosmic Vision program scheduled to be launched in 2017. STIX applies a Fourier-imaging technique using a set of tungsten grids (at pitches from 0.038 to 1 mm) in front of 32 pixelized CdTe detectors to provide imaging spectroscopy of solar thermal and non-thermal hard X-ray emissions from 4 to 150 keV. The status of the instrument reviewed in this paper is based on the design that passed the Preliminary Design Review (PDR) in early 2012. Particular emphasis is given to the first light of the detector system called Caliste-SO.

  15. A versatile medium-resolution x-ray emission spectrometer for diamond anvil cell applications

    SciTech Connect

    Mortensen, D. R.; Seidler, G. T.; Bradley, J. A.; Lipp, M. J.; Evans, W. J.; Chow, P.; Xiao, Y.-M.; Boman, G.; Bowden, M. E.

    2013-08-15

    We present design and performance details for a polycapillary-coupled x-ray spectrometer that provides very high collection efficiency at a moderate energy resolution suitable for many studies of nonresonant x-ray emission spectroscopy, especially for samples of heavy elements under high pressures. Using a single Bragg analyzer operating close to backscattering geometry so as to minimize the effect of the weak divergence of the quasicollimated exit beam from the polycapillary optic, this instrument can maintain a typical energy resolution of 5 eV over photon energies from 5 keV to 10 keV. We find dramatically improved count rates as compared to a traditional higher-resolution instrument based on a single spherically bent crystal analyzer.

  16. A Versatile Medium-Resolution X-ray Emission Spectrometer for Diamond Anvil Cell Applications

    SciTech Connect

    Mortensen, Devon R.; Seidler, G. T.; Bradley, J. A.; Lipp, M. J.; Evans, W. J.; Chow, P.; Xiao, Y. M.; Boman, G.; Bowden, Mark E.

    2013-08-28

    We present design and performance details for a polycapillary-coupled x-ray spectrometer that provides very high collection efficiency at a moderate energy resolution suitable for many studies of nonresonant x-ray emission spectroscopy, especially for samples of heavy elements under high pressures. Using a single Bragg analyzer operating close to a backscattering so as to minimize the effect of the weak divergence of the quasicollimated exit beam from the polycapillary optic, this instrument can maintain a typical energy resolution of 5 eV over photon energies from 5 keV to 10 keV. We find dramatically improved count rates as compared to a traditional higher-resolution instrument based on a single spherically-bent crystal analyzer.

  17. A versatile medium-resolution x-ray emission spectrometer for diamond anvil cell applications.

    PubMed

    Mortensen, D R; Seidler, G T; Bradley, J A; Lipp, M J; Evans, W J; Chow, P; Xiao, Y-M; Boman, G; Bowden, M E

    2013-08-01

    We present design and performance details for a polycapillary-coupled x-ray spectrometer that provides very high collection efficiency at a moderate energy resolution suitable for many studies of nonresonant x-ray emission spectroscopy, especially for samples of heavy elements under high pressures. Using a single Bragg analyzer operating close to backscattering geometry so as to minimize the effect of the weak divergence of the quasicollimated exit beam from the polycapillary optic, this instrument can maintain a typical energy resolution of 5 eV over photon energies from 5 keV to 10 keV. We find dramatically improved count rates as compared to a traditional higher-resolution instrument based on a single spherically bent crystal analyzer.

  18. A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility

    SciTech Connect

    Moore, A S; Guymer, T M; Kline, J L; Morton, J; Taccetti, M; Lanier, N E; Bentley, C; Workman, J; Peterson, B; Mussack, K; Cowan, J; Prasad, R; Richardson, M; Burns, S; Kalantar, D H; Benedetti, L R; Bell, P; Bradley, D; Hsing, W; Stevenson, M

    2012-05-01

    A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors (GXD) it records sixteen time-gated spectra between 250 and 1000eV with 100ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and VUV beamline at the National Synchrotron Light Source (NSLS), evidence a <100{micro}m spatial resolution in combination with a source-size limited spectral resolution that is <10eV at photon energies of 300eV.

  19. A multi-cone x-ray imaging Bragg crystal spectrometer

    DOE PAGES

    Bitter, M.; Hill, K. W.; Gao, Lan; Efthimion, P. C.; Delgado-Apariccio, L.; Lazerson, S.; Pablant, N.

    2016-08-26

    This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. Furthermore, these unique imaging properties are obtained by bending the x-raymore » diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.« less

  20. Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

    NASA Technical Reports Server (NTRS)

    Iwanczyk, J. S.; Wang, Y. J.; Dorri, N.; Dabrowski, A. J.; Economou, T. E.

    1991-01-01

    The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

  1. A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility

    SciTech Connect

    Moore, A. S.; Guymer, T. M.; Morton, J.; Bentley, C.; Stevenson, M.; Kline, J. L.; Taccetti, M.; Lanier, N. E.; Workman, J.; Peterson, B.; Mussack, K.; Cowan, J.; Prasad, R.; Richardson, M.; Burns, S.; Kalantar, D. H.; Benedetti, L. R.; Bell, P.; Bradley, D.; Hsing, W.

    2012-10-15

    A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors it records 16 time-gated spectra between 250 and 1000 eV with 100 ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300 eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and vacuum ultraviolet beamline at the National Synchrotron Light Source, evidence a <100 {mu}m spatial resolution in combination with a source-size limited spectral resolution that is <10 eV at photon energies of 300 eV.

  2. Calibration of X-ray spectrometers for opacity experiments at the Orion laser facility (invited)

    NASA Astrophysics Data System (ADS)

    Bentley, C.; Allan, P.; Brent, K.; Bruce, N.; Hoarty, D.; Meadowcroft, A.; Percival, J.; Opie, C.

    2016-11-01

    Accurately calibrated and characterised x-ray diagnostics are a key requirement in the fielding of experiments on the Orion laser where absolute measurements of x-ray emission are used to underpin the validity of models of emissivity and opacity. Diffraction crystals are used in spectrometers on Orion to record the dispersed spectral features emitted by the laser produced plasma to obtain a measurement of the plasma conditions. The ability to undertake diffraction crystal calibrations supports the successful outcome of these Orion experiments. This paper details the design and commissioning of a system to undertake these calibrations in the energy range 2.0 keV to approximately 8.5 keV. Improvements to the design are detailed which will extend the commissioned range of energies to below 1 keV.

  3. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments

    SciTech Connect

    Harding, E. C.; Ao, T.; Bailey, J. E.; Loisel, G.; Sinars, D. B.; Geissel, M.; Rochau, G. A.; Smith, I. C.

    2015-04-15

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-rays with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.

  4. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments.

    PubMed

    Harding, E C; Ao, T; Bailey, J E; Loisel, G; Sinars, D B; Geissel, M; Rochau, G A; Smith, I C

    2015-04-01

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-rays with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.

  5. Analysis and implementation of a space resolving spherical crystal spectrometer for x-ray Thomson scattering experiments

    NASA Astrophysics Data System (ADS)

    Harding, E. C.; Ao, T.; Bailey, J. E.; Loisel, G.; Sinars, D. B.; Geissel, M.; Rochau, G. A.; Smith, I. C.

    2015-04-01

    The application of a space-resolving spectrometer to X-ray Thomson Scattering (XRTS) experiments has the potential to advance the study of warm dense matter. This has motivated the design of a spherical crystal spectrometer, which is a doubly focusing geometry with an overall high sensitivity and the capability of providing high-resolution, space-resolved spectra. A detailed analysis of the image fluence and crystal throughput in this geometry is carried out and analytical estimates of these quantities are presented. This analysis informed the design of a new spectrometer intended for future XRTS experiments on the Z-machine. The new spectrometer collects 6 keV x-rays with a spherically bent Ge (422) crystal and focuses the collected x-rays onto the Rowland circle. The spectrometer was built and then tested with a foam target. The resulting high-quality spectra prove that a spherical spectrometer is a viable diagnostic for XRTS experiments.

  6. Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak

    SciTech Connect

    Lu, B.; Wang, F.; Fu, J.; Li, Y.; Wan, B.; Shi, Y.; Bitter, M.; Hill, K. W.; Lee, S. G.

    2012-10-15

    Two imaging x-ray crystal spectrometers, the so-called 'poloidal' and 'tangential' spectrometers, were recently implemented on experimental advanced superconducting tokamak (EAST) to provide spatially and temporally resolved impurity ion temperature (T{sub i}), electron temperature (T{sub e}) and rotation velocity profiles. They are derived from Doppler width of W line for Ti, the intensity ratio of Li-like satellites to W line for Te, and Doppler shift of W line for rotation. Each spectrometer originally consisted of a spherically curved crystal and a two-dimensional multi-wire proportional counter (MWPC) detector. Both spectrometers have now been upgraded. The layout of the tangential spectrometer was modified, since it had to be moved to a different port, and the spectrometer was equipped with two high count rate Pilatus detectors (Model 100 K) to overcome the count rate limitation of the MWPC and to improve its time resolution. The poloidal spectrometer was equipped with two spherically bent crystals to record the spectra of He-like and H-like argon simultaneously and side by side on the original MWPC. These upgrades are described, and new results from the latest EAST experimental campaign are presented.

  7. Mission Overview of the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat

    NASA Astrophysics Data System (ADS)

    Woods, Thomas N.; Caspi, Amir; Chamberlin, Phillip C.; Jones, Andrew; Kohnert, Rick; Li, Xinlin; Mason, James; Moore, Christopher; Palo, Scott; Rouleau, Colden; Solomon, Stanley

    2016-05-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3-Unit (3U) CubeSat to study the energy distribution of solar flare soft X-ray (SXR) emissions of the quiet Sun, active regions, and during flares and to model the solar SXR impact in Earth’s ionosphere, thermosphere, and mesosphere (ITM) using these MinXSS solar measurements. The energy variability in the SXR range can vary by more than a factor of 100, yet we have limited spectral measurements in the SXR to accurately quantify the spectral dependence of this variability. Energy from SXR radiation is deposited mostly in the ionospheric E-region, from ~80 to ~150 km, but the precise altitude is strongly dependent on the SXR spectrum because of the steep slope and structure of the photoionization cross sections of atmospheric gases in this wavelength range. The new MinXSS solar SXR spectra measurements and associated modeling of the solar spectra and Earth’s ITM response will address these outstanding issues. MinXSS includes an Amptek X123 X-ray spectrometer to measure solar irradiance spectra from 0.5 - 30 keV [2.5- 0.04 nm] with a nominal 0.15 keV energy resolution [spectral resolution of 0.7 nm at 2.5 nm and 0.0002 nm at 0.04 nm] and a SXR photometer with similar spectral sensitivity. Both of these SXR instruments had pre-flight calibrations with an accuracy of about 5% at the National Institute for Standard and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). This presentation will include an overview of the MinXSS CubeSat design and development that involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder. The MinXSS CubeSat was launched in December 2015 to the International Space Station (ISS) and awaits deployment from the ISS in April-May 2016. Assuming MinXSS has been deployed before June, we also intend to present first light observations from MinXSS to highlight solar SXR spectra and SXR variability

  8. Mission Overview of the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat

    NASA Astrophysics Data System (ADS)

    Woods, Thomas N.; Caspi, Amir; Chamberlin, Phillip C.; Jones, Andrew; Kohnert, Rick; Li, Xinlin; Mason, James; Moore, Christopher; Palo, Scott; Rouleau, Colden; Solomon, Stanley

    2016-05-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3-Unit (3U) CubeSat to study the energy distribution of solar flare soft X-ray (SXR) emissions of the quiet Sun, active regions, and during flares and to model the solar SXR impact in Earth’s ionosphere, thermosphere, and mesosphere (ITM) using these MinXSS solar measurements. The energy variability in the SXR range can vary by more than a factor of 100, yet we have limited spectral measurements in the SXR to accurately quantify the spectral dependence of this variability. Energy from SXR radiation is deposited mostly in the ionospheric E-region, from ~80 to ~150 km, but the precise altitude is strongly dependent on the SXR spectrum because of the steep slope and structure of the photoionization cross sections of atmospheric gases in this wavelength range. The new MinXSS solar SXR spectra measurements and associated modeling of the solar spectra and Earth’s ITM response will address these outstanding issues. MinXSS includes an Amptek X123 X-ray spectrometer to measure solar irradiance spectra from 0.5 – 30 keV [2.5– 0.04 nm] with a nominal 0.15 keV energy resolution [spectral resolution of 0.7 nm at 2.5 nm and 0.0002 nm at 0.04 nm] and a SXR photometer with similar spectral sensitivity. Both of these SXR instruments had pre-flight calibrations with an accuracy of about 5% at the National Institute for Standard and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). This presentation will include an overview of the MinXSS CubeSat design and development that involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder. The MinXSS CubeSat was launched in December 2015 to the International Space Station (ISS) and awaits deployment from the ISS in April-May 2016. Assuming MinXSS has been deployed before June, we also intend to present first light observations from MinXSS to highlight solar SXR spectra and SXR variability

  9. Combined backscatter Moessbauer spectrometer/x ray fluorescence analyzer (BaMS/XRF) for extraterrestrial surfaces

    NASA Technical Reports Server (NTRS)

    Shelfer, T. D.; Wills, E. L.; Agresti, D. G.; Pimperl, M. M.; Shen, M. H.; Morris, R. V.; Nguyen, T.

    1993-01-01

    We have designed and tested a prototype combined backscatter Moessbauer spectrometer and x-ray fluorescence analyzer (BaMS/XRF). A space qualified instrument based on this design would be suitable for in-situ use on planetary missions to the surfaces of the Moon (Artemis and lunar outpost), Mars (MESUR), asteroids, or other solid solar system objects. The BaMS/XRF instrument is designed to be capable of concurrent sample analyses for the mineralogy of iron-bearing phases and elemental composition without the need for sample preparation.

  10. A portable micro-X-ray fluorescence spectrometer with polycapillary optics and vacuum chamber for archaeometric and other applications

    NASA Astrophysics Data System (ADS)

    Buzanich, G.; Wobrauschek, P.; Streli, C.; Markowicz, A.; Wegrzynek, D.; Chinea-Cano, E.; Bamford, S.

    2007-11-01

    A portable focused-beam XRF spectrometer was designed, constructed, and manufactured. The spectrometer allows to detect and perform analysis of chemical elements from Na upwards. The system is equipped with a compact vacuum chamber to reduce absorption of both the excitation and the fluorescence radiation in air. A low power Pd-anode tube operated up to 50 kV and 1 mA with a point focus of 400 μm is used as excitation source. A polycapillary lens with a spot size of about 160 μm, or a collimator with a 1 mm inner diameter can be used alternatively for either focusing or collimating the primary beam. The fluorescence radiation is collected by an Si drift detector with an active area of 10 mm 2 and equipped with an 8 μm Be entrance window. A compact vacuum chamber was designed to house the X-ray beam optics and the detector snout. The chamber is attached to the X-ray tube and can be pumped down to 0.1 mbar. A Kapton™ window of 7.5 μm thickness allows to locate the investigated spot at about 1-2 mm distance outside of the chamber, thus minimizing absorption losses in the excitation and X-ray fluorescence radiation paths. Two lasers pointers are mounted inside the chamber. The laser beams cross at a point outside the chamber in front of the entrance window and coincide with the focal spot of the polycapillary. This paper reports some preliminary results obtained from an in situ analysis of bronze samples as well as a comparison of these data with those given by other laboratory spectrometers and the reference values provided by the Italian bronze foundry Venturi Arte Bologna, Italy.

  11. Spatial resolution of a spherical x-ray crystal spectrometer at various magnifications

    NASA Astrophysics Data System (ADS)

    Gao, Lan; Hill, K. W.; Bitter, M.; Efthimion, P. C.; Delgado-Aparicio, L.; Pablant, N. A.; Baronova, E. O.; Pereira, N. R.

    2016-11-01

    A high spatial resolution of a few μm is often required for probing small-scale high-energy-density plasmas using high resolution x-ray imaging spectroscopy. This resolution can be achieved by adjusting system magnification to overcome the inherent limitation of the detector pixel size. Laboratory experiments on investigating the relation between spatial resolution and system magnification for a spherical crystal spectrometer are presented. Tungsten Lβ2 rays from a tungsten-target micro-focus x-ray tube were diffracted by a Ge 440 crystal, which was spherically bent to a radius of 223 mm, and imaged onto an x-ray CCD with 13-μm pixel size. The source-to-crystal (p) and crystal-to-detector (q) distances were varied to produce spatial magnifications (M = q/p) ranging from 2 to 10. The inferred instrumental spatial width reduces with increasing system magnification M. However, the experimental measurement at each M is larger than the theoretical value of pixel size divided by M. Future work will focus on investigating possible broadening mechanisms that limit the spatial resolution.

  12. Dual x-ray fluorescence spectrometer and method for fluid analysis

    DOEpatents

    Wilson, Bary W.; Shepard, Chester L.

    2005-02-22

    Disclosed are an X-ray fluorescence (SRF) spectrometer and method for on-site and in-line determination of contaminant elements in lubricating oils and in fuel oils on board a marine vessel. An XRF source block 13 contains two radionuclide sources 16, 17 (e.g. Cd 109 and Fe 55), each oriented 180 degrees from the other to excite separate targets. The Cd 109 source 16 excites sample lube oil flowing through a low molecular weight sample line 18. The Fe 55 source 17 excites fuel oil manually presented to the source beam inside a low molecular weight vial 26 or other container. Two separate detectors A and B are arranged to detect the fluorescent x-rays from the targets, photons from the analyte atoms in the lube oil for example, and sulfur identifying x-rays from bunker fuel oil for example. The system allows both automated in-line and manual on-site analysis using one set of signal processing and multi-channel analyzer electronics 34, 37 as well as one computer 39 and user interface 43.

  13. Equation-of-State Measurements of Resorcinol Formaldehyde Foam Using Imaging X-Ray Thomson Spectrometer

    NASA Astrophysics Data System (ADS)

    Belancourt, Patrick; Theobald, W.; Keiter, P. A.; Collins, T. J. B.; Bonino, M. J.; Kozlowski, P.; Drake, R. P.

    2015-11-01

    Understanding the equation of state of materials under shocked conditions is important for laboratory astrophysics and high-energy-density physics experiments. This talk will focus on experiments dedicated to developing a platform for measuring the equation of state of shocked foams on OMEGA EP. The foam used in the development of this platform is resorcinol formaldehyde foam with an initial density of 0.34 g/cc. One OMEGA EP beam drives a shock into the foam, while the remaining three beams irradiate a nickel foil to create the x-ray backlighter. The primary diagnostic for this platform, the imaging x-ray Thomson spectrometer (IXTS), spectrally resolves the scattered x-ray beam while imaging in one spatial dimension. The IXTS is ideally suited to measure plasma conditions upstream, downstream and at the shock front in the foam. Preliminary results from these experiments will be shown. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944, the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas DE-NA0001840, and by the National Laser User Facility Program DE-NA0000850.

  14. The NEAR-Shoemaker x-ray/gamma-ray spectrometer experiment: Overview and lessons learned

    NASA Astrophysics Data System (ADS)

    Trombka, J. I.; Nittler, L. R.; Starr, R. D.; Evans, L. G.; McCoy, T. J.; Boynton, W. V.; Burbine, T. H.; Brückner, J.; Gorenstein, P.; Squyres, S. W.; Reedy, R. C.; Goldsten, J. O.; Lim, L.; Hurley, K.; Clark, P. E.; Floyd, S. R.; McClanahan, T. P.; McCartney, E.; Branscomb, J.; Bhangoo, J. S.; Mikheeva, I.; Murphy, M. E.

    2001-12-01

    The near-Earth asteroid rendezvous (NEAR)-Shoemaker remote-sensing x-ray/gamma-ray spectrometer (XGRS) completed more than a year of operation in orbit and on the surface of 433 Eros. Elemental compositions for a number of regions on the surface of Eros have been derived from analyses of the characteristic x-ray and gamma-ray emission spectra. The NEAR XGRS detection system was included as part of the interplanetary network (IPN) for the detection and localization of gamma-ray bursts (GRBs). Preliminary results for both the elemental composition of the surface of Eros and the detection of GRBs have been obtained. In addition to the science results, the design and operation of the NEAR XGRS is considered. Significant information important for the design of future remote sensing XGRS systems has been obtained and evaluated. We focus on four factors that became particularly critical during NEAR: (1) overall spacecraft design, (2) selection of materials, (3) increase of the signal-to-noise ratio and (4) knowledge of the incident solar x-ray spectrum.

  15. Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facilitya)

    NASA Astrophysics Data System (ADS)

    Seely, J. F.; Szabo, C. I.; Feldman, U.; Hudson, L. T.; Henins, A.; Audebert, P.; Brambrink, E.

    2010-10-01

    The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

  16. Hard x-ray transmission crystal spectrometer at the OMEGA-EP laser facility.

    PubMed

    Seely, J F; Szabo, C I; Feldman, U; Hudson, L T; Henins, A; Audebert, P; Brambrink, E

    2010-10-01

    The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum. PMID:21034000

  17. The Miniature X-ray Solar Spectrometer (MinXSS) CubeSat: instrument characterization techniques, instrument capabilities and solar science objectives.

    NASA Astrophysics Data System (ADS)

    Moore, Christopher; Caspi, Amir; Woods, Thomas N.; Mason, James

    2016-05-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3U CubeSat launched in December 2015 to the International Space Station for deployment in early 2016. MinXSS will utilize a commercial off the shelf (COTS) X-ray spectrometer from Amptek to measure the solar irradiance from 0.5 – 30 keV with a nominal 0.15 keV FWHM spectral resolution at 5.9 keV and a LASP developed X-ray photometer with similar spectral sensitivity. MinXSS design and development has involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder.The majority of previous solar X-ray measurements have been either at high spectral resolution with a narrow bandpass or spectrally integrating (broad band) photometers. MinXSS will conduct unique soft X-ray measurements of moderate spectral resolution over a relatively large energy range to study solar active region evolution, solar flares, and their effects on Earth’s ionosphere. This presentation focuses on the science instrument characterization involving radioactive X-ray sources and the National Institute for Standard and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). Detector spectral response, spectral resolution, response linearity are discussed as well as future solar science objectives.

  18. The Miniature X-ray Solar Spectrometer (MinXSS) CubeSat: instrument characterization techniques, instrument capabilities and solar science objectives.

    NASA Astrophysics Data System (ADS)

    Moore, Christopher; Caspi, Amir; Woods, Thomas N.; Mason, James

    2016-05-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3U CubeSat launched in December 2015 to the International Space Station for deployment in early 2016. MinXSS will utilize a commercial off the shelf (COTS) X-ray spectrometer from Amptek to measure the solar irradiance from 0.5 - 30 keV with a nominal 0.15 keV FWHM spectral resolution at 5.9 keV and a LASP developed X-ray photometer with similar spectral sensitivity. MinXSS design and development has involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder.The majority of previous solar X-ray measurements have been either at high spectral resolution with a narrow bandpass or spectrally integrating (broad band) photometers. MinXSS will conduct unique soft X-ray measurements of moderate spectral resolution over a relatively large energy range to study solar active region evolution, solar flares, and their effects on Earth’s ionosphere. This presentation focuses on the science instrument characterization involving radioactive X-ray sources and the National Institute for Standard and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). Detector spectral response, spectral resolution, response linearity are discussed as well as future solar science objectives.

  19. Progress report on the Astro-H Soft X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Kelley, Richard L.; Mitsuda, Kazuhisa

    2016-04-01

    We describe the initial in-orbit operations and performance of the Astro-H Soft X-Ray Spectrometer (SXS). Astro-H, JAXA's sixth X-ray observatory, is scheduled for launch on February 12, 2016, from the Tanegashima Space Center in Japan abord an H-IIA rocket. The instrument is based on a 36-pixel array of microcalorimeters designed for high resolution over the 0.3-12 keV energy band at the focus of a high throughput, grazing-incidence x-ray mirror. The instrument is the result of a joint collaboration between the JAXA Institute of Space and Astronautical Science and many partners in Japan, and the NASA/Goddard Space Flight Center and collaborators in the US. The principal components of the spectrometer are the microcalorimeter detector system, a low-temperature anticoincidence detector, a 3-stage adiabatic demagnetization refrigerator (ADR) to maintain 50 mK operation under both cryogen and cryogen-free operation, a hybrid liquid helium/cryogen-free dewar with both Stirling and Joule-Thomson coolers, electronics for reading out the array, processing the x-ray data for spectroscopy, and operating the ADR and cryocoolers. The dewar is closed out by an aperture system with five thin-film filters designed to provide high x-ray transmission with low heat loads to the dewar and detector system, and prevent contamination from condensing on the filters. The instrument was designed to have better than 7 eV energy resolution, and was demonstrated to achieve 4-5 eV resolution across the array at the full spacecraft level of integration during extensive ground testing prior to launch. The overall cooling chain has been designed to provide a lifetime of at least 3 years in orbit, and continue to operate without liquid helium to provide redundancy and the longest operational lifetime for the instrument. In this presentation, we will describe the early phases of the SXS instrument in orbit and provide a sense of the astronomical results that can be expected. This presentation is

  20. Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal.

    PubMed

    Seely, John F; Henins, Albert; Feldman, Uri

    2016-05-01

    A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating to selected angles, the spectrometer can operate with high resolution up to 50 keV. PMID:27250386

  1. Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal

    NASA Astrophysics Data System (ADS)

    Seely, John F.; Henins, Albert; Feldman, Uri

    2016-05-01

    A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating to selected angles, the spectrometer can operate with high resolution up to 50 keV.

  2. Ultrahigh resolution soft x-ray emission spectrometer at BL07LSU in SPring-8.

    PubMed

    Harada, Yoshihisa; Kobayashi, Masaki; Niwa, Hideharu; Senba, Yasunori; Ohashi, Haruhiko; Tokushima, Takashi; Horikawa, Yuka; Shin, Shik; Oshima, Masaharu

    2012-01-01

    An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution ΔE < 100 meV and/or an E∕ΔE ~ 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 μm) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/ΔE = 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.

  3. A novel von Hamos spectrometer for efficient X-ray emission spectroscopy in the laboratory

    SciTech Connect

    Anklamm, Lars Schlesiger, Christopher; Malzer, Wolfgang; Grötzsch, Daniel; Neitzel, Michael; Kanngießer, Birgit

    2014-05-15

    We present a novel, highly efficient von Hamos spectrometer for X-ray emission spectroscopy (XES) in the laboratory using highly annealed pyrolitic graphite crystals as the dispersive element. The spectrometer covers an energy range from 2.5 keV to 15 keV giving access to chemical speciation and information about the electronic configuration of 3d transition metals by means of the Kβ multiplet. XES spectra of Ti compounds are presented to demonstrate the speciation capabilities of the instrument. A spectral resolving power of E/ΔE = 2000 at 8 keV was achieved. Typical acquisition times range from 10 min for bulk material to hours for thin samples below 1 μm.

  4. Spectrometer for X-ray emission experiments at FERMI free-electron-laser

    SciTech Connect

    Poletto, L. Frassetto, F.; Miotti, P.; Di Cicco, A.; Iesari, F.; Finetti, P.; Grazioli, C.; Kivimäki, A.; Stagira, S.; Coreno, M.

    2014-10-15

    A portable and compact photon spectrometer to be used for photon in-photon out experiments, in particular x-ray emission spectroscopy, is presented. The instrument operates in the 25–800 eV energy range to cover the full emissions of the FEL1 and FEL2 stages of FERMI. The optical design consists of two interchangeable spherical varied-lined-spaced gratings and a CCD detector. Different input sections can be accommodated, with/without an entrance slit and with/without an additional relay mirror, that allow to mount the spectrometer in different end-stations and at variable distances from the target area both at synchrotron and at free-electron-laser beamlines. The characterization on the Gas Phase beamline at ELETTRA Synchrotron (Italy) is presented.

  5. Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal.

    PubMed

    Seely, John F; Henins, Albert; Feldman, Uri

    2016-05-01

    A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating to selected angles, the spectrometer can operate with high resolution up to 50 keV.

  6. Ultrahigh resolution soft x-ray emission spectrometer at BL07LSU in SPring-8

    SciTech Connect

    Harada, Yoshihisa; Kobayashi, Masaki; Senba, Yasunori; Ohashi, Haruhiko; Tokushima, Takashi; Horikawa, Yuka; Oshima, Masaharu

    2012-01-15

    An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution {Delta}E < 100 meV and/or an E/{Delta}E{approx} 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 {mu}m) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/{Delta}E= 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.

  7. X-rays From Quasars and Active Galaxies

    NASA Technical Reports Server (NTRS)

    Lightman, Alan P.

    1981-01-01

    Features of quasars and active galactic nuclei are discussed and include: the nature of the power source, the radiation processes, and the mechanism for the formation and collimation of long-lived jets of matter observed to emanate from the center of these of these objects. The phenomena that produce X-rays are highlighted.

  8. Design and performance of AERHA, a high acceptance high resolution soft x-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Chiuzbǎian, Sorin G.; Hague, Coryn F.; Avila, Antoine; Delaunay, Renaud; Jaouen, Nicolas; Sacchi, Maurizio; Polack, François; Thomasset, Muriel; Lagarde, Bruno; Nicolaou, Alessandro; Brignolo, Stefania; Baumier, Cédric; Lüning, Jan; Mariot, Jean-Michel

    2014-04-01

    A soft x-ray spectrometer based on the use of an elliptical focusing mirror and a plane varied line spacing grating is described. It achieves both high resolution and high overall efficiency while remaining relatively compact. The instrument is dedicated to resonant inelastic x-ray scattering studies. We set out how this optical arrangement was judged best able to guarantee performance for the 50 - 1000 eV range within achievable fabrication targets. The AERHA (adjustable energy resolution high acceptance) spectrometer operates with an effective angular acceptance between 100 and 250 μsr (energy dependent) and a resolving power well in excess of 5000 according to the Rayleigh criterion. The high angular acceptance is obtained by means of a collecting pre-mirror. Three scattering geometries are available to enable momentum dependent measurements with 135°, 90°, and 50° scattering angles. The instrument operates on the Synchrotron SOLEIL SEXTANTS beamline which serves as a high photon flux 2 × 200 μm2 focal spot source with full polarization control.

  9. Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF)

    NASA Astrophysics Data System (ADS)

    Hill, K. W.; Bitter, M.; Delgado-Aparicio, L.; Efthimion, P. C.; Ellis, R.; Gao, L.; Maddox, J.; Pablant, N. A.; Schneider, M. B.; Chen, H.; Ayers, S.; Kauffman, R. L.; MacPhee, A. G.; Beiersdorfer, P.; Bettencourt, R.; Ma, T.; Nora, R. C.; Scott, H. A.; Thorn, D. B.; Kilkenny, J. D.; Nelson, D.; Shoup, M.; Maron, Y.

    2016-11-01

    A high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-β (1s2-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heβ complex and (2) the Heα (1s2-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heβ spectral range onto an image plate to provide a time integrated calibration spectrum. Calculations of source x-ray intensity, spectrometer throughput, and spectral resolution are presented. Details of the conical-crystal focusing properties as well as the status of the instrumental design are also presented.

  10. Design and performance of AERHA, a high acceptance high resolution soft x-ray spectrometer.

    PubMed

    Chiuzbăian, Sorin G; Hague, Coryn F; Avila, Antoine; Delaunay, Renaud; Jaouen, Nicolas; Sacchi, Maurizio; Polack, François; Thomasset, Muriel; Lagarde, Bruno; Nicolaou, Alessandro; Brignolo, Stefania; Baumier, Cédric; Lüning, Jan; Mariot, Jean-Michel

    2014-04-01

    A soft x-ray spectrometer based on the use of an elliptical focusing mirror and a plane varied line spacing grating is described. It achieves both high resolution and high overall efficiency while remaining relatively compact. The instrument is dedicated to resonant inelastic x-ray scattering studies. We set out how this optical arrangement was judged best able to guarantee performance for the 50 - 1000 eV range within achievable fabrication targets. The AERHA (adjustable energy resolution high acceptance) spectrometer operates with an effective angular acceptance between 100 and 250 μsr (energy dependent) and a resolving power well in excess of 5000 according to the Rayleigh criterion. The high angular acceptance is obtained by means of a collecting pre-mirror. Three scattering geometries are available to enable momentum dependent measurements with 135°, 90°, and 50° scattering angles. The instrument operates on the Synchrotron SOLEIL SEXTANTS beamline which serves as a high photon flux 2 × 200 μm(2) focal spot source with full polarization control.

  11. Design and performance of AERHA, a high acceptance high resolution soft x-ray spectrometer

    SciTech Connect

    Chiuzbăian, Sorin G. Hague, Coryn F.; Brignolo, Stefania; Baumier, Cédric; Lüning, Jan; Avila, Antoine; Delaunay, Renaud; Mariot, Jean-Michel; Jaouen, Nicolas; Polack, François; Thomasset, Muriel; Lagarde, Bruno; Nicolaou, Alessandro; Sacchi, Maurizio

    2014-04-15

    A soft x-ray spectrometer based on the use of an elliptical focusing mirror and a plane varied line spacing grating is described. It achieves both high resolution and high overall efficiency while remaining relatively compact. The instrument is dedicated to resonant inelastic x-ray scattering studies. We set out how this optical arrangement was judged best able to guarantee performance for the 50 − 1000 eV range within achievable fabrication targets. The AERHA (adjustable energy resolution high acceptance) spectrometer operates with an effective angular acceptance between 100 and 250 μsr (energy dependent) and a resolving power well in excess of 5000 according to the Rayleigh criterion. The high angular acceptance is obtained by means of a collecting pre-mirror. Three scattering geometries are available to enable momentum dependent measurements with 135°, 90°, and 50° scattering angles. The instrument operates on the Synchrotron SOLEIL SEXTANTS beamline which serves as a high photon flux 2 × 200 μm{sup 2} focal spot source with full polarization control.

  12. Horizontal Ampoule Growth and Characterization of Mercuric Iodide at Controlled Gas Pressures for X-Ray and Gamma Ray Spectrometers

    SciTech Connect

    McGregor, Douglas S.; Ariesanti, Elsa; Corcoran, Bridget

    2004-04-30

    The project developed a new method for producing high quality mercuric iodide crystals of x-ray and gamma spectrometers. Included are characterization of mercuric iodide crystal properties as a function of growth environment and fabrication and demonstration of room-temperature-operated high-resolution mercuric iodide spectrometers.

  13. Fast Monitoring Soil Environmental Qualities of Heavy Metal by Portable X-Ray Fluorescence Spectrometer.

    PubMed

    Wang, Bao; Yu, Jian-xin; Huang, Biao; Hu, Wen-you; Chang, Qing

    2015-06-01

    Portable X-ray fluorescence (PXRF) spectrometer as a new type of equipment for quick test has a prominent prospect, but there are also shortcomings of detection range and limition, therefore this paper studied the suitability of PXRF spectrometer in monitoring soil environmental qualities of heavy metals included Cr, Ni, Cu, Zn, Pb, Cd, As and Hg, the aim of this paper is to screen elements which can be detected by this kind of instrument and evaluate the accuracy of test results. The research method is to test heavy metals contaminated soil samples by PXRF spectrometer, evaluate the accuracy of test results of PXRF compared with inductively coupled plasma mass(ICP-MS), then establish linear regression relationship between analysis results of PXRF and ICP-MS method. The results show that, (1) When measuring the soil environmental quality, PXRF spectrometer is appropriate to measure the content of Pb, Zn, Cr and Cu, except Ni, Cd, As and Hg. (2) Compared with the test value of ICP-MS, the test value of Pb and Zn is lower, the test value of Cu is higher, the test value of Cr is too high, all the results of PXRF spectrometer should be linear corrected according to standard analysis method. In conclusion, PXRF spectrometer is suitable for monitoring environmental quality of soil which is polluted by heavy metal such as Pb, Zn, Cr and Cu, it is an analysis means with characteristics of simple and rapid, accurate and reliable. The innovation of this article is that reasonable avoiding the shortcomings of PXRF spectrometer as using the instrument to monitor soil environmental quality, at last improved the application value of test results.

  14. Spectroscopic Investigations of Highly Charged Ions using X-Ray Calorimeter Spectrometers

    SciTech Connect

    Thorn, Daniel Bristol

    2008-11-19

    Spectroscopy of K-shell transitions in highly charged heavy ions, like hydrogen-like uranium, has the potential to yield information about quantum electrodynamics (QED) in extremely strong nuclear fields as well as tests of the standard model, specifically parity violation in atomic systems. These measurements would represent the 'holy grail' in high-Z atomic spectroscopy. However, the current state-of-the-art detection schemes used for recording the K-shell spectra from highly charged heavy ions does not yet have the resolving power to be able to attain this goal. As such, to push the field of high-Z spectroscopy forward, new detectors must be found. Recently, x-ray calorimeter spectrometers have been developed that promise to make such measurements. In an effort to make the first steps towards attaining the 'holy grail', measurements have been performed with two x-ray calorimeter spectrometers (the XRS/EBIT and the ECS) designed and built at Goddard Space Flight Center in Greenbelt, MD. The calorimeter spectrometers have been used to record the K-shell spectra of highly charged ions produced in the SuperEBIT electron beam ion trap at Lawrence Livermore National Laboratory in Livermore, CA. Measurements performed with the XRS/EBIT calorimeter array found that the theoretical description of well-above threshold electron-impact excitation cross sections for hydrogen-like iron and nickel ions are correct. Furthermore, the first high-resolution spectrum of hydrogen-like through carbon-like praseodymium ions was recorded with a calorimeter. In addition, the new high-energy array on the EBIT Calorimeter Spectrometer (ECS) was used to resolve the K-shell x-ray emission spectrum of highly charged xenon ions, where a 40 ppm measurement of the energy of the K-shell resonance transition in helium-like xenon was achieved. This is the highest precision result, ever, for an element with such high atomic number. In addition, a first-of-its-kind measurement of the effect of the

  15. Active X-ray mirror development at UCL: preliminary results

    NASA Astrophysics Data System (ADS)

    Atkins, Carolyn; Doel, Peter; Yao, Jun; Brooks, David; Thompson, Samantha; Willingale, Richard; Feldman, Charlotte; Button, Tim; Zhang, Dou; James, Ady

    2007-12-01

    The Smart X-ray Optics project is a UK based consortium consisting of several institutions to investigate the application of active/adaptive optics upon both small and large scale grazing incidence x-ray optics. The work done at University College London (UCL) focuses on the application of piezoelectric materials to large scale optics in order to actively deform the mirror's surface. These optics are geared towards the next generation of x-ray telescopes and it is hoped that the project will be able to achieve a resolution greater than that currently available by Chandra (0.5"). One of the aims of the consortium is to produce a working prototype. The initial design is based on a thin nickel ellipsoid segment with an x-ray reflective coating, on the back of which will be bonded a series of piezoelectric actuators. Investigation into the specification of the design of an active x-ray optic prototype and suitable support test structure has been undertaken. The dimensions and constraints upon the prototype, and the manufacturing process to produce a nickel shell are discussed. Finite element analysis (FEA) of the physical characteristics of piezoelectric materials has shown the ability to deform the nickel surface to correct for errors of several microns. FEA has also been utilised in the specification of the prototype's support structure to ensure that gravitational sag upon the optic is kept to a minimum. Laboratory experiments have tested a series of materials, different actuators and bonding methods, which could then be applied to the prototype.

  16. High-resolution bent-crystal spectrometer for the ultra-soft x-ray region

    SciTech Connect

    Beiersdorfer, P.; von Goeler, S.; Bitter, M.; Hill, K.W.; Hulse, R.A.; Walling, R.S.

    1988-10-01

    A multichannel vacuum Brag-crystal spectrometer has been developed for high-resolution measurements of the line emission from tokamak plasmas in the wavelength region between 4 and 25 /angstrom/. The spectrometer employs a bent crystal in Johann geometry and a microchannel-plate intensified photodiode array. The instrument is capable of measuring high-resolution spectra (lambda/..delta..lambda approx. 3000) with fast time resolution (4 msec per spectrum) and good spatial resolution (3 cm). The spectral bandwidth is ..delta..lambda/lambda/sub 0/ = 8/angstrom/. A simple tilt mechanism allows access to different wavelength intervals. In order to illustrate the utility of the new spectrometer, time- and space-resolved measurements of the n = 3 to n = 2 spectrum of selenium from the Princeton Large Torus tokamak plasmas are presented. The data are used to determine the plasma transport parameters and to infer the radial distribution of fluorinelike, neonlike, and sodiumlike ions of selenium in the plasma. The new ultra-soft x-ray spectrometer has thus enabled us to demonstrate the utility of high-resolution L-shell spectroscopy of neonlike ions as a fusion diagnostic. 43 refs., 23 figs.

  17. Improved micro x-ray fluorescence spectrometer for light element analysis

    SciTech Connect

    Smolek, Stephan; Streli, Christina; Zoeger, Norbert; Wobrauschek, Peter

    2010-05-15

    Since most available micro x-ray fluorescence (micro-XRF) spectrometers operate in air, which does not allow the analysis of low-Z elements (Z{<=}14), a special micro-XRF spectrometer has been designed to extend the analytical range down to light elements (Z{>=}6). It offers improved excitation and detection conditions necessary for light element analysis. To eliminate absorption of the exciting and fluorescent radiation, the system operates under vacuum condition. Sample mapping is automated and controlled by specialized computer software developed for this spectrometer. Several different samples were measured to test and characterize the spectrometer. The spot size has been determined by scans across a 10 {mu}m Cu wire which resulted in a full width at half maximum of 31 {mu}m for Mo K{alpha} line (17.44 keV) and 44 {mu}m effective beam size for the Cu K edge and 71 {mu}m effective beam size for the Cu L edge. Lower limits of detection in the picogram range for each spot (or {mu}g/cm{sup 2}) were obtained by measuring various thin metal foils under different conditions. Furthermore, detection limits in the parts per million range were found measuring NIST621 standard reference material. Area scans of a microscopic laser print and NaF droplet were performed to show mapping capabilities.

  18. High-resolution Bent-crystal Spectrometer for the Ultra-soft X-ray Region

    DOE R&D Accomplishments Database

    Beiersdorfer, P.; von Goeler, S.; Bitter, M.; Hill, K. W.; Hulse, R. A.; Walling, R. S.

    1988-10-01

    A multichannel vacuum Brag-crystal spectrometer has been developed for high-resolution measurements of the line emission from tokamak plasmas in the wavelength region between 4 and 25 angstrom. The spectrometer employs a bent crystal in Johann geometry and a microchannel-plate intensified photodiode array. The instrument is capable of measuring high-resolution spectra (lambda/..delta..lambda approx. 3000) with fast time resolution (4 msec per spectrum) and good spatial resolution (3 cm). The spectral bandwidth is ..delta..lambda/lambda{sub 0} = 8 angstrom. A simple tilt mechanism allows access to different wavelength intervals. In order to illustrate the utility of the new spectrometer, time- and space-resolved measurements of the n = 3 to n = 2 spectrum of selenium from the Princeton Large Torus tokamak plasmas are presented. The data are used to determine the plasma transport parameters and to infer the radial distribution of fluorinelike, neonlike, and sodiumlike ions of selenium in the plasma. The new ultra-soft x-ray spectrometer has thus enabled us to demonstrate the utility of high-resolution L-shell spectroscopy of neonlike ions as a fusion diagnostic.

  19. Unwrapping the X-ray spectra of active galactic nuclei

    NASA Astrophysics Data System (ADS)

    Reynolds, C. S.

    2016-05-01

    Active galactic nuclei (AGN) are complex phenomena. At the heart of an AGN is a relativistic accretion disk around a spinning supermassive black hole (SMBH) with an X-ray emitting corona and, sometimes, a relativistic jet. On larger scales, the outer accretion disk and molecular torus act as the reservoirs of gas for the continuing AGN activity. And on all scales from the black hole outwards, powerful winds are seen that probably affect the evolution of the host galaxy as well as regulate the feeding of the AGN itself. In this review article, we discuss how X-ray spectroscopy can be used to study each of these components. We highlight how recent measurements of the high-energy cutoff in the X-ray continuum by NuSTAR are pushing us to conclude that X-ray coronae are radiatively-compact and have electron temperatures regulated by electron-positron pair production. We show that the predominance of rapidly-rotating objects in current surveys of SMBH spin is entirely unsurprising once one accounts for the observational selection bias resulting from the spin-dependence of the radiative efficiency. We review recent progress in our understanding of fast (v˜ (0.1-0.3)c, highly-ionized (mainly visible in Fe XXV and Fe XXVI lines), high-column density winds that may dominate quasar-mode galactic feedback. Finally, we end with a brief look forward to the promise of Astro-H and future X-ray spectropolarimeters.

  20. A new compact soft x-ray spectrometer for resonant inelastic x-ray scattering studies at PETRA III

    SciTech Connect

    Yin, Z. E-mail: simone.techert@desy.de; Peters, H. B.; Hahn, U.; Viefhaus, J.; Agåker, M.; Nordgren, J.; Hage, A.; Reininger, R.; Siewert, F.; Techert, S. E-mail: simone.techert@desy.de

    2015-09-15

    We present a newly designed compact grating spectrometer for the energy range from 210 eV to 1250 eV, which would include the Kα{sub 1,2} emission lines of vital elements like C, N, and O. The spectrometer is based on a grazing incidence spherical varied line spacing grating with 2400 l/mm at its center and a radius of curvature of 58 542 mm. First, results show a resolving power of around 1000 at an energy of 550 eV and a working spectrometer for high vacuum (10{sup −4} mbar) environment without losing photon intensity.

  1. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    SciTech Connect

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  2. Arrays of silicon drift detectors for an extraterrestrial X-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Rehak, Pavel; Carini, Gabriella; Chen, Wei; De Geronimo, Gianluigi; Fried, Jack; Li, Zheng; Pinelli, Donald A.; Peter Siddons, D.; Vernon, Emerson; Gaskin, Jessica A.; Ramsey, Brian D.

    2010-12-01

    Arrays of Silicon Drift Detectors (SDD) were designed, produced and tested. These arrays are the central part of an X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C-Fe) fluoresced by ambient radiation on the investigated celestial object. The basic building element (or cell) of the arrays consists of a single hexagonal SDD. Signal electrons drift toward the center of the hexagon where a very low capacitance anode is located. The hexagonal shape of an individual SDD allows for a continuous covering of large detection areas of various shapes. To match the number of SDD cells with the external Application Specific Integrated Circuit (ASIC), two arrays, one with 16 and another with 64 cells were developed. One side of SDDs, called the window side, is a continuous thin rectifying junction through which the X-ray radiation enters the detector. The opposite side, called the device side contains electron collecting anodes as well as all other electrodes needed to generate the drift field and to sink leakage current produced on Si-SiO 2 interface. On both sides of the detector array there is a system of guard rings, which smoothly adjusts the voltage of the boundary cells to the ground potential of the silicon outside the sensitive volume. The drift voltage inside the detector is generated by an implanted rectifying contact, which forms a hexagonal spiral. This spiral produces the main valley where signal electrons drift as well as the voltage divider to produce the drift field. System performance is shown by a spectrum of Mn X-rays produced by the decay of 55Fe.

  3. The Alpha Particle X-Ray Spectrometer (APXS): Results from Gusev Crater and Calibration Report

    NASA Technical Reports Server (NTRS)

    Gellert, R.; Rieder, R.; Brueckner, J.; Clark, B.; Dreibus, G.; Klingelhoefer, G.; Lugmair, G.; Ming, D.; Waenke, H.; Yen, A.; Zipfel, J.; Squyres, S.

    2006-01-01

    The chemical composition of rocks and soils on Mars analyzed during the Mars Exploration Rover Spirit Mission was determined by X-ray analyses with the Alpha Particle X-Ray Spectrometer (APXS). Details of the data analysis method and the instrument calibration are presented. Measurements performed on Mars to address geometry effects and background contributions are shown. Cross calibration measurements among several instrument sensors and sources are discussed. An unintentional swap of the two flight instruments is evaluated. New concentration data acquired during the first 470 sols of rover Spirit in Gusev Crater are presented. There are two geological regions, the Gusev plains and the Columbia Hills. The plains contain soils that are very similar to previous landing sites on Mars. A meteoritic component in the soil is identified. Rocks in the plains revealed thin weathering rinds. The underlying abraded rock was classified as primitive basalt. One of these rocks contained significant Br that is probably associated with vein-filling material of different composition. One of the trenches showed large subsurface enrichments of Mg, S, and Br. Disturbed soils and rocks in the Columbia Hills revealed different elemental compositions. These rocks are significantly weathered and enriched in mobile elements, such as P, S, Cl, or Br. Even abraded rock surfaces have high Br concentrations. Thus, in contrast to the rocks and soils in the Gusev Plains, the Columbia Hills material shows more significant evidence of ancient aqueous alteration.

  4. Plane-grating flat-field soft x-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Hague, C. F.; Underwood, J. H.; Avila, A.; Delaunay, R.; Ringuenet, H.; Marsi, M.; Sacchi, M.

    2005-02-01

    We describe a soft x-ray spectrometer covering the 120-800 eV range. It is intended for resonant inelastic x-ray scattering experiments performed at third generation synchrotron radiation (SR) facilities and has been developed with SOLEIL, the future French national SR source in mind. The Hettrick-Underwood principle is at the heart of the design using a combination of varied line-spacing plane grating and spherical-mirror to provide a flat-field image. It is slitless for optimum acceptance. This means the source size determines the resolving power. A spot size of ⩽5μm is planned at SOLEIL which, according to simulations, should ensure a resolving power ⩾1000 over the whole energy range. A 1024×1024 pixel charge-coupled device (CCD) with a 13μm×13μm pixel size is used. This is an improvement on the use of microchannel-plate detectors, both as concerns efficiency and spatial resolution. Additionally spectral line curvature is avoided by the use of a horizontal focusing mirror concentrating the beam in the nondispersing direction. It allows for readout using a binning mode to reduce the intrinsically large CCD readout noise. Preliminary results taken at beamlines at Elettra (Trieste) and at BESSY (Berlin) are presented.

  5. The LCLS variable-energy hard X-ray single-shot spectrometer.

    PubMed

    Rich, David; Zhu, Diling; Turner, James; Zhang, Dehong; Hill, Bruce; Feng, Yiping

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10(-5) or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

  6. Preliminary results of equation of state measurements using imaging x-ray Thomson spectrometer

    NASA Astrophysics Data System (ADS)

    Belancourt, Patrick; Theobald, Wolfgang; Keiter, Paul; Collins, Timothy; Bonino, Mark; Kozlowski, Pawel; Drake, Paul; University of Michigan Team; LaboratoryLaser Energetics Team; University of Oxford Team

    2014-10-01

    Understanding the equation of state of materials under shocked conditions is important for laboratory astrophysics and high-energy-density physics experiments. The goal of the experiments discussed here is to create a platform for equation of state measurements in shocked foams on Omega EP. The target of interest for these experiments is shocked carbonized resorcinol formaldehyde foam with an initial density of 0.34 g/cc. Lasers irradiate an ablator, driving a shock into the foam. Plasma conditions ahead of the shock, at the shock and behind the shock are diagnosed using the imaging x-ray Thomson spectrometer (IXTS). The IXTS is capable of spectrally resolving the scattered x-ray beam while imaging in one spatial dimension. Preliminary results from these experiments will be shown. This work is funded by the U.S. Department of Energy, through the NNSA-DS and SC-OFES Joint Program in High-Energy-Density Laboratory Plasmas, grant number DE-NA0001840, and the National Laser User Facility Program, Grant Number DE-NA0000850, and through the Laboratory for Laser Energetics, University of Rochester by the NNSA/OICF under Cooperative Agreement No. DE-FC52-08NA28302.

  7. A wide-acceptance Compton spectrometer for spectral characterization of a medical x-ray source

    NASA Astrophysics Data System (ADS)

    Espy, Michelle A.; Gehring, A.; Belian, A.; Haines, T.; Hunter, J.; James, M.; Klasky, M.; Mendez, J.; Moir, D.; Sedillo, R.; Shurter, R.; Stearns, J.; Van Syoc, K.; Volegov, P.

    2016-03-01

    Accurate knowledge of the x-ray spectra used in medical treatment and radiography is important for dose calculations and material decomposition analysis. Indirect measurements via transmission through materials are possible. However, such spectra are challenging to measure directly due to the high photon fluxes. One method of direct measurement is via a Compton spectrometer (CS) method. In this approach, the x-rays are converted to a much lower flux of electrons via Compton scattering on a converter foil (typically beryllium or aluminum). The electrons are then momentum selected by bending in a magnetic field. With tight angular acceptance of electrons into the magnet of ~ 1 deg, there is a linear correlation between incident photon energy and electron position recorded on an image plate. Here we present measurements of Bremsstrahlung spectrum from a medical therapy machine, a Scanditronix M22 Microtron. Spectra with energy endpoints from 6 to 20 MeV are directly measured, using a CS with a wide energy range from 0.5 to 20 MeV. We discuss the sensitivity of the device and the effects of converter material and collimation on the accuracy of the reconstructed spectra. Approaches toward improving the sensitivity, including the use of coded apertures, and potential future applications to characterization of spectra are also discussed.

  8. The LCLS variable-energy hard X-ray single-shot spectrometer

    SciTech Connect

    Rich, David; Zhu, Diling; Turner, James; Zhang, Dehong; Hill, Bruce; Feng, Yiping

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10-5or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

  9. The LCLS variable-energy hard X-ray single-shot spectrometer

    SciTech Connect

    Rich, David; Zhu, Diling; Turner, James; Zhang, Dehong; Hill, Bruce; Feng, Yiping

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10-5or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

  10. The LCLS variable-energy hard X-ray single-shot spectrometer.

    PubMed

    Rich, David; Zhu, Diling; Turner, James; Zhang, Dehong; Hill, Bruce; Feng, Yiping

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10(-5) or better. Those performance goals have all been achieved during the commissioning of the HXSSS. PMID:26698039

  11. Miniature X-Ray Solar Spectrometer: A Science-Oriented, University 3U CubeSat

    NASA Astrophysics Data System (ADS)

    Mason, James P.; Woods, Thomas N.; Caspi, Amir; Chamberlin, Phillip C.; Moore, Christopher; Jones, Andrew; Kohnert, Rick; Li, Xinlin; Palo, Scott; Solomon, Stanley C.

    2016-03-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3-Unit (3U) CubeSat developed at the Laboratory for Atmospheric and Space Physics (LASP) at the University of Colorado, Boulder (CU). Over 40 students contributed to the project with professional mentorship and technical contributions from professors in the Aerospace Engineering Sciences Department at CU and from LASP scientists and engineers. The scientific objective of MinXSS is to study processes in the dynamic Sun, from quiet-Sun to solar flares, and to further understand how these changes in the Sun influence the Earth's atmosphere by providing unique spectral measurements of solar soft x-rays (SXRs). The enabling technology providing the advanced solar SXR spectral measurements is the Amptek X123, a commercial-off-the-shelf (COTS) silicon drift detector (SDD). The Amptek X123 has a low mass (~324 g after modification), modest power consumption (~2.50 W), and small volume (6.86 cm x 9.91 cm x 2.54 cm), making it ideal for a CubeSat. This paper provides an overview of the MinXSS mission: the science objectives, project history, subsystems, and lessons learned that can be useful for the small-satellite community.

  12. Performance of a Borehole X-ray Fluorescence Spectrometer for Planetary Exploration

    NASA Technical Reports Server (NTRS)

    Kelliher, Warren C.; Carlberg, Ingrid A.; Elam, W. T.; Willard-Schmoe, Ella

    2008-01-01

    We have designed and constructed a borehole X-ray Fluorescence Spectrometer (XRFS) as part of the Mars Subsurface Access program [1]. It can be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary requirements and performance metrics for the instrument are to obtain parts-per-million (ppm) lower limits of detection over a wide range of elements in the periodic table (Magnesium to Lead). Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight ppm for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

  13. A Dual Channel X-ray Spectrometer for Fast Ignition Research

    SciTech Connect

    Akli, K U; Patel, P K; Van Maren, R; Stephens, R B; Key, M H; Higginson, D P; Westover, B; Chen, C D; Mackinnon, A J; Bartal, T; Beg, F N; Chawla, S; Fedosejevs, R; Freeman, R R; Hey, D S; Kemp, G E; LePape, S; Link, A; Ma, T; MacPhee, A G; McLean, H S; Ping, Y; Tsui, Y Y; Van Woerkom, L D; Wei, M S; Yabuuchi, T

    2010-04-19

    A new Dual Channel Highly Ordered Pyrolytic Graphite (DC-HOPG) x-ray spectrometer was developed to study laser-generated electron beam transport. The instrument uses a pair of graphite crystals and has the advantage of simultaneously detecting self emission from low-Z materials in first diffraction order and high-Z materials in second order. The emissions from the target are detected using a pair of parallel imaging plates positioned in a such way that the noise from background is minimized and the mosaic focusing is achieved. Initial tests of the diagnostic on Titan laser (I {approx} 10{sup 20} W/cm{sup 2}, {tau} = 0.7 ps) show excellent signal-to-noise ratio (SNR) > 1000 for the low energy channel and SNR > 400 for the high energy channel.

  14. [Temperature effect correction for Chang'E-3 alpha particle X-ray spectrometer].

    PubMed

    Wu, Ming-Ye; Wang, Huan-Yu; Peng, Wen-Xi; Zhang, Cheng-Mo; Zhang, Jia-Yu; Cui, Xing-Zhu; Liang, Xiao-Hua; Wang, Jin-Zhou; Yang, Jia-Wei; Fan, Rui-Rui; Liu, Ya-Qing; Dong, Yi-Fan; Wu, Feng; Zhao, Xiao-Yun

    2012-07-01

    Alpha particle X-ray spectrometer (APXS) is one of the payloads of Chang'E-3 lunar rover of China's Lunar Exploration Project. The present paper introduces briefly the components of APXS, how it works and its working environment on the lunar surface. The environmental temperature effect has been studied with simulations and experiments, and the results show that the temperature of the APXS sensor will be varying during the measuring on the lunar surface. And another experiment reveals that the energy resolution becomes worse if the sensor's temperature is varying. In this paper, a correction method based on Pearson's chi-squared test is presented. The method can improve the energy resolution when the sensor's temperature is varying. We have tested the method with the spectra acquired by APXS in the temperature varying period of Temperature Cycling Test, and the results show that the method is efficient and reliable.

  15. Design and Test of a Deployable Radiation Cover for the REgolith X-Ray Imaging Spectrometer

    NASA Technical Reports Server (NTRS)

    Carte, David B.; Inamdar, Niraj K.; Jones, Michael P.; Masterson, Rebecca A.

    2014-01-01

    The REgolith X-ray Imaging Spectrometer (REXIS) instrument contains a one-time deployable radiation cover that is opened using a shape memory alloy actuator (a "Frangibolt") from TiNi Aerospace and two torsion springs. The door will be held closed by the bolt for several years in cold storage during travel to the target asteroid, Bennu, and it is imperative to gain confidence that the door will open at predicted operational temperatures. This paper briefly covers the main design features of the radiation cover and measures taken to mitigate risks to cover deployment. As the chosen FD04 model Frangibolt actuator has minimal flight heritage, the main focus of this paper is the testing, results and conclusions with the FD04 while discussing key lessons learned with respect to the use of the FD04 actuator in this application.

  16. Data Acquisition, Control, Communication and Computation System of Solar X-ray Spectrometer (SOXS) Mission

    NASA Astrophysics Data System (ADS)

    Shah, Amish B.; Vadher, N. M.; Jain, Rajma; Dave, Hemant; Shah, Vishal; Manian, K. S. B.; Kayasth, Satish; Patel, Vinod; Ubale, Girish; Shah, Kirit; Solanki, Chirag; Deshpande, M. R.; Sharma, Ramkrishna; Umapathy, C. N.; Viswanath, N.; Kulkarni, Ravi; Kumar, P. S.

    2006-09-01

    The Solar X-ray Spectrometer (SOXS) mission onboardGSAT- 2 Indian Spacecraft was launched on 08 May 2003 using GSLV-D2 rocket by Indian Space Research Organization (ISRO). SOXS aims to study solar flares, which are the most violent and energetic phenomena in the solar system, in the energy range of 4-56 keV with high spectral and temporal resolution. SOXS employs state-of-the-art semiconductor devices, viz., Si-Pin and CZT detectors to achieve sub-keV energy resolution requirements. In this paper, we present an overview of data acquisition, control,communication and computation of low energy payload of the SOXS mission.

  17. Soft x-ray spectrometer operation at the National Ignition Facility

    SciTech Connect

    Schein, J; Dewald, E; Campbell, K; Turner, R; Weber, F; Rhodes, M; Landen, O; Schneider, M B; Lee, D; Tran, V; Pellinen, D

    2006-04-25

    Radiation drive diagnostics during the NIF early light campaign was supported by an 18 channel soft x-ray spectrometer (Dante). In order to achieve a measurement accuracy of 2% in radiation temperature absolute calibration of the individual channels was necessary and signal distortion through long transmission lines had to be compensated for as well. For fast signals the signal attenuation due to the long (50m) cables amounted to {approx} 20% {at} 100MHz, which was corrected by a cable compensation in the frequency domain. The varying effects of cable distortion for a variety of signals between 1ns and 9ns in length were evaluated and corrections were applied. Results of the thus calculated temperatures of the NEL campaign will be presented compared to LASNEX predictions, showing agreement in peak radiation temperature within less than 2%.

  18. Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

    SciTech Connect

    Millecchia, M.; Regan, S. P.; Bahr, R. E.; Romanofsky, M.; Sorce, C.

    2012-10-15

    The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

  19. Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega.

    PubMed

    Millecchia, M; Regan, S P; Bahr, R E; Romanofsky, M; Sorce, C

    2012-10-01

    The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO∕QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals. PMID:23126929

  20. Reflection grating spectrometer for the x-ray multi-mirror (XMM) space observatory: design and calculated performance

    SciTech Connect

    Hettrick, M.C.; Kahn, S.M.

    1985-10-01

    A spectrometer design candidate is presented for the X-ray Multi-Mirror (XMM) observatory, being planned by the European Space Agency (ESA) as a long-lived large-area of telescopes. The science requirement of moderate resolution (E/..delta..E approx.100) spectroscopy in a two octave region (0.5 to 2 keV) with extremely high throughput (effective area > 500 cm/sup 2/) results in the use of grazing incidence reflection gratings. Due to the low image quality of the telescopes (approx. 1 minute of arc), the grating dispersion must be maximized by use of the classical grating mount in which the spectrum is dispersed within the plane of incident radiation. Due to the small field of view by the x-ray telescopes, the gratings must be situated in the converging beam at the exit of the telescope. A spectrometer module consists of a thin-foil conical mirror telescope, a stack of plane varied-space reflection gratings and an imaging proportional counter. This system is analyzed on the basis of dispersion, geometric aberrations and efficiency. At a spectral resolution of 0.15 A, a twenty module XMM would attain an average effective area of approx.900 cm/sup 2/, reaching twice this value at the peak wavelength (15 A). Similar throughput is obtained in second order centered at 7.5 A, the two spectral orders separated by the non-dispersive energy resolution of the proportional counter. Continuous spectra are obtained in the 6-25 A band (0.5 to 2 keV), and can be extended to 45 A if desired by tuning of the grating. The instrument sensitivity is sufficient to allow the first spectral detection of soft x-ray features in external galaxies, with access to an estimated population of several hundred active galactic nuclei. Such observations will expand vastly the roles feasible for spectroscopy in x-ray astrophysics, marking the beginning of a new era in space astronomy.

  1. Non-destructive in situ study of "Mad Meg" by Pieter Bruegel the Elder using mobile X-ray fluorescence, X-ray diffraction and Raman spectrometers

    NASA Astrophysics Data System (ADS)

    Van de Voorde, Lien; Van Pevenage, Jolien; De Langhe, Kaat; De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo; Vandenabeele, Peter; Martens, Maximiliaan P. J.

    2014-07-01

    "Mad Meg", a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO2 + 15% K2O + 10% CoO + 5% Al2O3) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel.

  2. Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer

    NASA Astrophysics Data System (ADS)

    Antier, S.; Ferrando, P.; Limousin, O.; Caroli, E.; Curado da Silva, R. M.; Blondel, C.; Chipaux, R.; Honkimaki, V.; Horeau, B.; Laurent, P.; Maia, J. M.; Meuris, A.; Del Sordo, S.; Stephen, J. B.

    2015-06-01

    Since the initial exploration of the X- and soft γ-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars, black holes, and Active Galactic Nuclei are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical processes in these high energy sources, allowing the discrimination between competing models which may otherwise all be consistent with other types of measurement. This is why most of the projects for the next generation of space missions covering the few tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability, in this energy range, is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The compact hard X-ray imaging spectrometer module, developed in CEA with the generic name of "Caliste" module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed to linearly polarized beams at the European Synchrotron Radiation Facility (ESRF). These results, obtained at 200 and 300 keV, demonstrate the capability of these modules to detect Compton events and to give an accurate determination of the polarization parameters (polarization angle and fraction) of the incoming beam. For example, applying an optimized selection to our data set, equivalent to select 90° Compton scattered interactions in the detector plane, we find a modulation factor Q of 0.78 ± 0.06 in the 200-300 keV range. The polarization angle and fraction are derived with accuracies of approximately 1° and 5 % respectively for both CdZnTe and CdTe crystals. The

  3. X-ray Photoexcited Extranuclear Gas in Active Galaxies

    NASA Astrophysics Data System (ADS)

    Marshall, Herman

    2015-10-01

    I will present a summary of results from 16 years of high resolution X-ray spectroscopy of gas in the neighborhood of Active Galactic Nuclei. Led by the prototypical Sy 2 galaxy NGC 1068, we now have many examples of circumnuclear gas that is excited by the central source. In galaxies with obscured nuclei, the gas is rich with emission lines from highly ionized species and radiative recombination continua. Outflows are apparent and several cases are resolved at the 1-5 level. The ionization models give velocity, density, and composition diagnostics. These outflows carry significant energy and momentum, affecting the energy budget of the local intergalactic medium. The X-ray Surveyor can examine the prevalence and impact of these ionization cones in the z1 universe.

  4. HI Emission in Nearby X-ray Detected Active Galaxies

    NASA Astrophysics Data System (ADS)

    George, Erin; Winter, L. M.; Zauderer, B.; Darling, J.; Koss, M.

    2013-01-01

    We have measured HI profiles in 96 nearby, active galaxies using the 100-meter Green Bank Telescope (GBT). Our sources contain active galactic nuclei (AGN) detected in the hard X-ray (14-195 keV) from Swift Gamma-ray Burst satellite’s Burst Alert Telescope (BAT) 22-month survey. This survey is unique because the sources were detected in the hard X-ray, allowing us to include galaxies that are otherwise obscured in other bands. The HI profiles we gathered are combined with the published optical, infrared, and X-ray data. We present the systemic velocities, outflow velocities, and cold gas mass in the sources. The mass of the cold gas is compared to the luminous mass in stars in order to find clues to unlock the nature of the host galaxies. A comparison of HI with the bolometric luminosity of the AGN is made. Our observations examine how the reservoir of cold gas is correlated with luminosity, as well. Through these data, we look for evolutionary differences in host galaxy types in order to understand how super massive black holes are fueled.

  5. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence.

    PubMed

    Wobrauschek, P; Prost, J; Ingerle, D; Kregsamer, P; Misra, N L; Streli, C

    2015-08-01

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm(2) active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration. PMID:26329172

  6. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    NASA Astrophysics Data System (ADS)

    Wobrauschek, P.; Prost, J.; Ingerle, D.; Kregsamer, P.; Misra, N. L.; Streli, C.

    2015-08-01

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  7. A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

    SciTech Connect

    Wobrauschek, P. Prost, J.; Ingerle, D.; Kregsamer, P.; Streli, C.; Misra, N. L.

    2015-08-15

    The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm{sup 2} active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

  8. An Elliptical Crystal Spectrometer Suitable for EXAFS Studies of Laser Compressed Materials and for High Resolution X-Ray Spectroscopy.

    PubMed

    Ridgeley, A; Goodman, D; Hall, T A

    1995-01-01

    Using an x-ray spectrometer with an elliptically curved crystal it is possible to study absorption spectra from a target placed at one focus of the ellipse using a backlighting source placed at the other focus. This principle has been used to develop a spectrometer for EXAFS studies of laser compressed materials. The backlighting source is placed at one focus of the ellipse and the laser compressed EXAFS sample at the other. Using this technique a small area of the EXAFS target can be probed, thereby minimizing any spatial variations in the compressed plasma due to nonuniformities in the laser beams. Also, the dispersive nature of the crystal ensures that it acts as a bandpass filter, so that the EXAFS sample is not probed by other x-ray wavelengths which may cause unwanted heating. Another advantage is that compressed and uncompressed EXAFS spectra can be compared on a single shot. The optical properties of the spectrometer are discussed analytically and using a computer ray-tracing program. The development and alignment of the elliptical spectrometer are discussed, and its performance using both x-ray film and a CCD detector is evaluated. The use of the elliptical spectrometer as a high-resolution x-ray instrument is presented. PMID:21307480

  9. Data reduction and analysis for the graphite crystal X-ray spectrometer and polarimeter experiment flown aboard OSO-8 spacecraft

    NASA Technical Reports Server (NTRS)

    Novick, R.

    1980-01-01

    The documentation and software programs developed for the reception, initial processing (quickbook), and production analysis of data obtained by solar X-ray spectroscopy, stellar spectroscopy, and X-ray polarimetry experiments on OSO-8 are listed. The effectiveness and sensitivity of the Bragg crystal scattering instruments used are assessed. The polarization data polarimetric data obtained shows that some X-ray sources are polarized and that a larger polarimeter of this type is required to perform the measurements necessary to fully understand the physics of X-ray sources. The scanning Bragg crystal spectrometer was ideally suited for studying rapidly changing solar conditions. Observations of the Crab Nebula and pulsar, Cyg X-1, Cyg X-2, Cyg X-3, Sco X-1, Cen X-3, and Her X-1 are discussed as well as of 4U1656-53 and 4U1820-30. Evidence was obtained for iron line emission from Cyg X-3.

  10. Metalloprotein active site structure determination: synergy between X-ray absorption spectroscopy and X-ray crystallography.

    PubMed

    Cotelesage, Julien J H; Pushie, M Jake; Grochulski, Pawel; Pickering, Ingrid J; George, Graham N

    2012-10-01

    Structures of metalloprotein active sites derived from X-ray crystallography frequently contain chemical anomalies such as unexpected atomic geometries or elongated bond-lengths. Such anomalies are expected from the known errors inherent in macromolecular crystallography (ca. 0.1-0.2Å) and from the lack of appropriate restraints for metal sites which are often without precedent in the small molecule structure literature. Here we review the potential of X-ray absorption spectroscopy to provide information and perspective which could aid in improving the accuracy of metalloprotein crystal structure solutions. We also review the potential problem areas in analysis of the extended X-ray absorption fine structure (EXAFS) and discuss the use of density functional theory as another possible source of geometrical restraints for crystal structure analysis of metalloprotein active sites.

  11. Imaging x-ray crystal spectrometers for the National Spherical Torus Experiment

    SciTech Connect

    Bitter, M.; Hill, K.W.; Roquemore, A.L.; Beiersdorfer, P.; Kahn, S.M.; Elliott, S.R.; Fraenkel, B.

    1999-01-01

    A new type of high-resolution x-ray imaging crystal spectrometers is described for implementation on the National Spherical Torus Experiment (NSTX) to provide spatially and temporally resolved data on the ion temperature, toroidal and poloidal plasma rotation, electron temperature, impurity ion-charge state distributions, and impurity transport. These data are derived from observations of the satellite spectra of heliumlike argon, ArthinspXVII, which is the dominant charge state for electron temperatures in the range from 0.4 to 3.0 keV and which is accessible to NSTX. Experiments at the Torus Experiment for Technology Oriented Research (TEXTOR) demonstrate that a throughput of 2{times}10{sup 5}thinspphotons/s (corresponding to the count-rate limit of the present detectors) can easily be obtained with small, nonperturbing argon gas puffs of less than 1{times}10{sup {minus}3}thinspTorrthinspscr(l)/s, so that it is possible to record spectra with a small statistical error and a good time resolution (typically 50 and 1 ms in some cases). Employing a novel design, which is based on the imaging properties of spherically bent crystals, the spectrometers will provide spectrally and spatially resolved images of the plasma for all experimental conditions, which include ohmically heated discharges as well as plasmas with rf and neutral-beam heating. The conceptual design, experimental results on the focusing properties, and relevant spectral data from TEXTOR are presented. {copyright} {ital 1999 American Institute of Physics.}

  12. A doubly curved elliptical crystal spectrometer for the study of localized x-ray absorption in hot plasmas

    SciTech Connect

    Cahill, Adam D. Hoyt, Cad L.; Pikuz, Sergei A.; Shelkovenko, Tania; Hammer, David A.

    2014-10-15

    X-ray absorption spectroscopy is a powerful tool for the diagnosis of plasmas over a wide range of both temperature and density. However, such a measurement is often limited to probing plasmas with temperatures well below that of the x-ray source in order to avoid object plasma emission lines from obscuring important features of the absorption spectrum. This has excluded many plasmas from being investigated by this technique. We have developed an x-ray spectrometer that provides the ability to record absorption spectra from higher temperature plasmas than the usual approach allows without the risk of data contamination by line radiation emitted by the plasma under study. This is accomplished using a doubly curved mica crystal which is bent both elliptically and cylindrically. We present here the foundational work in the design and development of this spectrometer along with initial results obtained with an aluminum x-pinch as the object plasma.

  13. Optimizing the operation of a high resolution vertical Johann spectrometer using a high energy fluorescer x-ray source

    SciTech Connect

    Haugh, Michael; Stewart, Richard

    2010-10-15

    This paper describes the operation and testing for a vertical Johann spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution of E/{Delta}E=3000 or better to measure the Doppler broadening of highly ionized krypton and operate at a small x-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy x-ray (HEX) source located at National Security Technologies (NSTec), LLC, in Livermore, CA. The HEX uses a 160 kV x-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

  14. Optimizing the Operation of a Vertical Johann Spectrometer Using a High Energy Fluorescer X-ray Source

    SciTech Connect

    Haugh, Michael; Stewart, Richard

    2010-10-01

    This paper describes the operation and testing for a Vertical Johann Spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution E/ΔE=3000 or better to measure Doppler broadening of highly ionized krypton and operate at a small X-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy X-ray (HEX) source located at National Security Technologies, LLC (NSTec), in Livermore, California. The HEX uses a 160 kV X-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

  15. Thermodynamic Performance of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

    NASA Technical Reports Server (NTRS)

    Shirron, Peter J.; Kimball, Mark O.; James, Bryan L.; Muench, Theodore; DiPirro, Michael J.; Bialas, Thomas G.; Sneiderman, Gary A.; Porter, Frederick S.; Kelley, Richard L.

    2015-01-01

    The Soft X-ray Spectrometer (SXS) instrument[1] on Astro-H[2] will use a 3-stage ADR[3] to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at =1.20 K as the heat sink[4]. In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and singleshot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

  16. Resonant inelastic X-ray scattering spectrometer with 25 meV resolution at the Cu K-edge.

    PubMed

    Ketenoglu, Didem; Harder, Manuel; Klementiev, Konstantin; Upton, Mary; Taherkhani, Mehran; Spiwek, Manfred; Dill, Frank Uwe; Wille, Hans Christian; Yavaş, Hasan

    2015-07-01

    An unparalleled resolution is reported with an inelastic X-ray scattering instrument at the Cu K-edge. Based on a segmented concave analyzer, featuring single-crystal quartz (SiO₂) pixels, the spectrometer delivers a resolution near 25 meV (FWHM) at 8981 eV. Besides the quartz analyzer, the performance of the spectrometer relies on a four-bounce Si(553) high-resolution monochromator and focusing Kirkpatrick-Baez optics. The measured resolution agrees with the ray-tracing simulation of an ideal spectrometer. The performance of the spectrometer is demonstrated by reproducing the phonon dispersion curve of a beryllium single-crystal.

  17. Resonant inelastic X-ray scattering spectrometer with 25meV resolution at the Cu K -edge

    DOE PAGES

    Ketenoglu, Didem; Harder, Manuel; Klementiev, Konstantin; Upton, Mary; Taherkhani, Mehran; Spiwek, Manfred; Dill, Frank-Uwe; Wille, Hans-Christian; Yavaş, Hasan

    2015-06-27

    An unparalleled resolution is reported with an inelastic X-ray scattering instrument at the CuK-edge. Based on a segmented concave analyzer, featuring single-crystal quartz (SiO2) pixels, the spectrometer delivers a resolution near 25meV (FWHM) at 8981eV. Besides the quartz analyzer, the performance of the spectrometer relies on a four-bounce Si(553) high-resolution monochromator and focusing Kirkpatrick–Baez optics. The measured resolution agrees with the ray-tracing simulation of an ideal spectrometer. The performance of the spectrometer is demonstrated by reproducing the phonon dispersion curve of a beryllium single-crystal.

  18. Optimizing and characterizing grating efficiency for a soft X-ray emission spectrometer.

    PubMed

    Boots, Mark; Muir, David; Moewes, Alexander

    2013-03-01

    The efficiency of soft X-ray diffraction gratings is studied using measurements and calculations based on the differential method with the S-matrix propagation algorithm. New open-source software is introduced for efficiency modelling that accounts for arbitrary groove profiles, such as those based on atomic force microscopy (AFM) measurements; the software also exploits multi-core processors and high-performance computing resources for faster calculations. Insights from these calculations, including a new principle of optimal incidence angle, are used to design a soft X-ray emission spectrometer with high efficiency and high resolution for the REIXS beamline at the Canadian Light Source: a theoretical grating efficiency above 10% and resolving power E/ΔE > 2500 over the energy range from 100 eV to 1000 eV are achieved. The design also exploits an efficiency peak in the third diffraction order to provide a high-resolution mode offering E/ΔE > 14000 at 280 eV, and E/ΔE > 10000 at 710 eV, with theoretical grating efficiencies from 2% to 5%. The manufactured gratings are characterized using AFM measurements of the grooves and diffractometer measurements of the efficiency as a function of wavelength. The measured and theoretical efficiency spectra are compared, and the discrepancies are explained by accounting for real-world effects: groove geometry errors, oxidation and surface roughness. A curve-fitting process is used to invert the calculations to predict grating parameters that match the calculated and measured efficiency spectra; the predicted blaze angles are found to agree closely with the AFM estimates, and a method of characterizing grating parameters that are difficult or impossible to measure directly is suggested.

  19. Novel handheld x-ray fluorescence spectrometer for routine testing for the presence of lead

    NASA Astrophysics Data System (ADS)

    Rensing, Noa M.; Tiernan, Timothy C.; Squillante, Michael R.

    2011-06-01

    RMD is developing a safe, inexpensive, and easy to operate lead detector for retailers and consumers that can reliably detect dangerous levels of lead in toys and other household products. Lead and its compounds have been rated as top chemicals that pose a great threat to human health. However, widespread testing for environmental lead is rarely undertaken until lead poisoning has already been diagnosed. The problem is not due to the accuracy or sensitivity of existing lead detection technology, but rather to the high expense, safety and licensing barriers of available test equipment. An inexpensive and easy to use lead detector would enable the identification of highly contaminated objects and areas and allow for timely and cost effective remediation. The military has similar needs for testing for lead and other heavy elements such as mercury, primarily in the decontamination of former military properties prior to their return to civilian use. RMD's research and development efforts are abased on advanced solid-state detectors combined with recently patented lead detection techniques to develop a consumer oriented lead detector that will be widely available and easy and inexpensive to use. These efforts will result in an instrument that offers: (1) high sensitivity, to identify objects containing dangerous amounts of lead, (2) low cost to encourage widespread testing by consumers and other end users and (3) convenient operation requiring no training or licensing. In contrast, current handheld x-ray fluorescence spectrometers either use a radioactive source requiring licensing and operating training, or use an electronic x-ray source that limits their sensitivity to surface lead.

  20. Chemical Bond Activation Observed with an X-ray Laser.

    PubMed

    Beye, Martin; Öberg, Henrik; Xin, Hongliang; Dakovski, Georgi L; Dell'Angela, Martina; Föhlisch, Alexander; Gladh, Jörgen; Hantschmann, Markus; Hieke, Florian; Kaya, Sarp; Kühn, Danilo; LaRue, Jerry; Mercurio, Giuseppe; Minitti, Michael P; Mitra, Ankush; Moeller, Stefan P; Ng, May Ling; Nilsson, Anders; Nordlund, Dennis; Nørskov, Jens; Öström, Henrik; Ogasawara, Hirohito; Persson, Mats; Schlotter, William F; Sellberg, Jonas A; Wolf, Martin; Abild-Pedersen, Frank; Pettersson, Lars G M; Wurth, Wilfried

    2016-09-15

    The concept of bonding and antibonding orbitals is fundamental in chemistry. The population of those orbitals and the energetic difference between the two reflect the strength of the bonding interaction. Weakening the bond is expected to reduce this energetic splitting, but the transient character of bond-activation has so far prohibited direct experimental access. Here we apply time-resolved soft X-ray spectroscopy at a free-electron laser to directly observe the decreased bonding-antibonding splitting following bond-activation using an ultrashort optical laser pulse. PMID:27584914

  1. Shuttle and Transfer Orbit Thermal Analysis and Testing of the Chandra X-Ray Observatory CCD Imaging Spectrometer Radiator Shades

    NASA Technical Reports Server (NTRS)

    Sharp, John R.

    2001-01-01

    Contents include the following: (1) Introduction: Chandra X-ray observatory. Advanced CCD imaging spectrometer. (2) LEO and transfer orbit analyses: Geometric modeling in TSS w/specularity. Low earth orbital heating calculations. (3) Thermal testing and LMAC. (4) Problem solving. (5) VDA overcoat analyses. (6) VDA overcoat testing and MSFC. (7) Post-MSFC test evaluation.

  2. Determination of Gd and Sm contents in metallofullerenes on a total reflection X-ray fluorescence spectrometer with parallel beam

    NASA Astrophysics Data System (ADS)

    Tikhonova, A. E.; Kozlov, V. S.

    2014-01-01

    The contents of Gd and Sm have been determined quantitatively using the X-ray fluorescence analysis on a total reflection spectrometer with a parallel beam. It has been shown that the results can be used in developments of the technique for measuring the content of Gd metallofullerenes in powder samples several milligrams in weight and in liquid samples several microliters in volume.

  3. A seven-crystal Johann-type hard x-ray spectrometer at the Stanford Synchrotron Radiation Lightsource

    SciTech Connect

    Sokaras, D.; Weng, T.-C.; Nordlund, D.; Velikov, P.; Wenger, D.; Garachtchenko, A.; George, M.; Borzenets, V.; Johnson, B.; Rabedeau, T.; Alonso-Mori, R.; Bergmann, U.

    2013-05-15

    We present a multicrystal Johann-type hard x-ray spectrometer ({approx}5-18 keV) recently developed, installed, and operated at the Stanford Synchrotron Radiation Lightsource. The instrument is set at the wiggler beamline 6-2 equipped with two liquid nitrogen cooled monochromators - Si(111) and Si(311) - as well as collimating and focusing optics. The spectrometer consists of seven spherically bent crystal analyzers placed on intersecting vertical Rowland circles of 1 m of diameter. The spectrometer is scanned vertically capturing an extended backscattering Bragg angular range (88 Degree-Sign -74 Degree-Sign ) while maintaining all crystals on the Rowland circle trace. The instrument operates in atmospheric pressure by means of a helium bag and when all the seven crystals are used (100 mm of projected diameter each), has a solid angle of about 0.45% of 4{pi} sr. The typical resolving power is in the order of (E/{Delta}E){approx}10 000. The spectrometer's high detection efficiency combined with the beamline 6-2 characteristics permits routine studies of x-ray emission, high energy resolution fluorescence detected x-ray absorption and resonant inelastic x-ray scattering of very diluted samples as well as implementation of demanding in situ environments.

  4. Experimental results from an X-ray imaging crystal spectrometer utilizing multi-wire proportional counter for KSTAR

    NASA Astrophysics Data System (ADS)

    Lee, S. G.; Yoo, J. W.; Kim, Y. S.; Nam, U. W.; Moon, M. K.

    2016-11-01

    The inconsistency of the first experimental results from the X-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research device utilizing a multi-wire proportional counter (MWPC) is clarified after improving the photon-count rate of the data acquisition system for the MWPC and ground loop isolator for the whole spectrometer system. The improved MWPC is successfully applied to pure Ohmic plasmas as well as plasmas with high confinement modes.

  5. High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

    SciTech Connect

    Porter, F. Scott; Adams, Joseph S.; Kelley, Richard L.; Kilbourne, Caroline A.; Beiersdorfer, Peter; Brown, Gregory V.; Clementson, Joel; Frankel, Miriam; Kahn, Steven M.

    2009-12-16

    The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

  6. High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

    SciTech Connect

    Porter, F S; Adams, J S; Beiersdorfer, P; Brown, G V; Clementson, J; Frankel, M; Kahn, S M; Kelley, R L; Kilbourne, C A

    2009-10-01

    The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

  7. X-Ray Psoralen Activated Cancer Therapy (X-PACT)

    PubMed Central

    Oldham, Mark; Yoon, Paul; Fathi, Zak; Beyer, Wayne F.; Adamson, Justus; Liu, Leihua; Alcorta, David; Xia, Wenle; Osada, Takuya; Liu, Congxiao; Yang, Xiao Y.; Dodd, Rebecca D.; Herndon, James E.; Meng, Boyu; Kirsch, David G.; Lyerly, H. Kim; Dewhirst, Mark W.; Fecci, Peter; Walder, Harold; Spector, Neil L.

    2016-01-01

    This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of solid cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with current application to proliferative disease and extracorporeal photopheresis (ECP) of cutaneous T Cell Lymphoma. An immunogenic role for light-activated psoralen has been reported, contributing to long-term clinical responses. Psoralen therapies have to-date been limited to superficial or extracorporeal scenarios due to the requirement for psoralen activation by UVA light, which has limited penetration in tissue. X-PACT solves this challenge by activating psoralen with UV light emitted from novel non-tethered phosphors (co-incubated with psoralen) that absorb x-rays and re-radiate (phosphoresce) at UV wavelengths. The efficacy of X-PACT was evaluated in both in-vitro and in-vivo settings. In-vitro studies utilized breast (4T1), glioma (CT2A) and sarcoma (KP-B) cell lines. Cells were exposed to X-PACT treatments where the concentrations of drug (psoralen and phosphor) and radiation parameters (energy, dose, and dose rate) were varied. Efficacy was evaluated primarily using flow cell cytometry in combination with complimentary assays, and the in-vivo mouse study. In an in-vitro study, we show that X-PACT induces significant tumor cell apoptosis and cytotoxicity, unlike psoralen or phosphor alone (p<0.0001). We also show that apoptosis increases as doses of phosphor, psoralen, or radiation increase. Finally, in an in-vivo pilot study of BALBc mice with syngeneic 4T1 tumors, we show that the rate of tumor growth is slower with X-PACT than with saline or AMT + X-ray (p<0.0001). Overall these studies demonstrate a potential therapeutic effect for X-PACT, and provide a foundation and rationale for future studies. In summary, X-PACT represents a novel treatment approach in which well-tolerated low doses of x-ray radiation are delivered to a specific tumor site to generate UVA light which

  8. X-Ray Psoralen Activated Cancer Therapy (X-PACT).

    PubMed

    Oldham, Mark; Yoon, Paul; Fathi, Zak; Beyer, Wayne F; Adamson, Justus; Liu, Leihua; Alcorta, David; Xia, Wenle; Osada, Takuya; Liu, Congxiao; Yang, Xiao Y; Dodd, Rebecca D; Herndon, James E; Meng, Boyu; Kirsch, David G; Lyerly, H Kim; Dewhirst, Mark W; Fecci, Peter; Walder, Harold; Spector, Neil L

    2016-01-01

    This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of solid cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with current application to proliferative disease and extracorporeal photopheresis (ECP) of cutaneous T Cell Lymphoma. An immunogenic role for light-activated psoralen has been reported, contributing to long-term clinical responses. Psoralen therapies have to-date been limited to superficial or extracorporeal scenarios due to the requirement for psoralen activation by UVA light, which has limited penetration in tissue. X-PACT solves this challenge by activating psoralen with UV light emitted from novel non-tethered phosphors (co-incubated with psoralen) that absorb x-rays and re-radiate (phosphoresce) at UV wavelengths. The efficacy of X-PACT was evaluated in both in-vitro and in-vivo settings. In-vitro studies utilized breast (4T1), glioma (CT2A) and sarcoma (KP-B) cell lines. Cells were exposed to X-PACT treatments where the concentrations of drug (psoralen and phosphor) and radiation parameters (energy, dose, and dose rate) were varied. Efficacy was evaluated primarily using flow cell cytometry in combination with complimentary assays, and the in-vivo mouse study. In an in-vitro study, we show that X-PACT induces significant tumor cell apoptosis and cytotoxicity, unlike psoralen or phosphor alone (p<0.0001). We also show that apoptosis increases as doses of phosphor, psoralen, or radiation increase. Finally, in an in-vivo pilot study of BALBc mice with syngeneic 4T1 tumors, we show that the rate of tumor growth is slower with X-PACT than with saline or AMT + X-ray (p<0.0001). Overall these studies demonstrate a potential therapeutic effect for X-PACT, and provide a foundation and rationale for future studies. In summary, X-PACT represents a novel treatment approach in which well-tolerated low doses of x-ray radiation are delivered to a specific tumor site to generate UVA light which

  9. 38 CFR 3.370 - Pulmonary tuberculosis shown by X-ray in active service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shown by X-ray in active service. 3.370 Section 3.370 Pensions, Bonuses, and Veterans' Relief DEPARTMENT... Rating Considerations Relative to Specific Diseases § 3.370 Pulmonary tuberculosis shown by X-ray in active service. (a) Active disease. X-ray evidence alone may be adequate for grant of direct...

  10. 38 CFR 3.370 - Pulmonary tuberculosis shown by X-ray in active service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... shown by X-ray in active service. 3.370 Section 3.370 Pensions, Bonuses, and Veterans' Relief DEPARTMENT... Rating Considerations Relative to Specific Diseases § 3.370 Pulmonary tuberculosis shown by X-ray in active service. (a) Active disease. X-ray evidence alone may be adequate for grant of direct...

  11. 38 CFR 3.370 - Pulmonary tuberculosis shown by X-ray in active service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... shown by X-ray in active service. 3.370 Section 3.370 Pensions, Bonuses, and Veterans' Relief DEPARTMENT... Rating Considerations Relative to Specific Diseases § 3.370 Pulmonary tuberculosis shown by X-ray in active service. (a) Active disease. X-ray evidence alone may be adequate for grant of direct...

  12. 38 CFR 3.370 - Pulmonary tuberculosis shown by X-ray in active service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shown by X-ray in active service. 3.370 Section 3.370 Pensions, Bonuses, and Veterans' Relief DEPARTMENT... Rating Considerations Relative to Specific Diseases § 3.370 Pulmonary tuberculosis shown by X-ray in active service. (a) Active disease. X-ray evidence alone may be adequate for grant of direct...

  13. 38 CFR 3.370 - Pulmonary tuberculosis shown by X-ray in active service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shown by X-ray in active service. 3.370 Section 3.370 Pensions, Bonuses, and Veterans' Relief DEPARTMENT... Rating Considerations Relative to Specific Diseases § 3.370 Pulmonary tuberculosis shown by X-ray in active service. (a) Active disease. X-ray evidence alone may be adequate for grant of direct...

  14. AEGIS: An Astrophysics Experiment for Grating and Imaging Spectroscopy---a Soft X-ray, High-resolution Spectrometer

    NASA Astrophysics Data System (ADS)

    Huenemoerder, David; Bautz, M. W.; Davis, J. E.; Heilmann, R. K.; Houck, J. C.; Marshall, H. L.; Neilsen, J.; Nicastro, F.; Nowak, M. A.; Schattenburg, M. L.; Schulz, N. S.; Smith, R. K.; Wolk, S.; AEGIS Team

    2012-01-01

    AEGIS is a concept for a high-resolution soft X-ray spectroscopic observatory developed in response to NASA's request for definitions of the next X-ray astronomy mission. At a small fraction of the cost of the once-planned International X-ray Observatory (IXO), AEGIS has capabilities that surpass IXO grating spectrometer requirements, and which are far superior to those of existing soft X-ray spectrometers. AEGIS incorporates innovative technology in X-ray optics, diffraction gratings and detectors. The mirror uses high area-to-mass ratio segmented glass architecture developed for IXO, but with smaller aperture and larger graze angles optimized for high-throughput grating spectroscopy with low mass and cost. The unique Critical Angle Transmission gratings combine low mass and relaxed figure and alignment tolerances of Chandra transmission gratings but with high diffraction efficiency and resolving power of blazed reflection gratings. With more than an order of magnitude better performance over Chandra and XMM grating spectrometers, AEGIS can obtain high quality spectra of bright AGN in a few hours rather than 10 days. Such high resolving power allows detailed kinematic studies of galactic outflows, hot gas in galactic haloes, and stellar accretion flows. Absorption line spectroscopy will be used to study large scale structure, cosmic feedback, and growth of black holes in thousands of sources to great distances. AEGIS will enable powerful multi-wavelength investigations, for example with Hubble/COS in the UV to characterize the intergalactic medium. AEGIS will be the first observatory with sufficient resolution below 1 keV to resolve thermally-broadened lines in hot ( 10 MK) plasmas. Here we describe key science investigations enable by Aegis, its scientific payload and mission plan. Acknowledgements: Support was provided in part by: NASA SAO contract SV3-73016 to MIT for the Chandra X-ray Center and Science Instruments; NASA grant NNX08AI62G; and the MKI

  15. Rapid X-Ray Variability of Active Galaxies. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Tennant, A. F., Jr.

    1983-01-01

    Active galactic nuclei are luminous sources of X-rays. The thesis that the X-rays are generated within 10 gravitational radii from the central object is tested. A very sensitive search for rapid ( 1 day) X-ray variability from active galaxies was made.

  16. Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments

    SciTech Connect

    Hill, K. W. Bitter, M.; Delgado-Aparacio, L.; Efthimion, P.; Pablant, N. A.; Lu, J.; Beiersdorfer, P.; Chen, H.; Magee, E.

    2014-11-15

    A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for Doppler measurements of ion temperature and plasma flow velocity profiles. Laboratory measurements demonstrate a resolving power, E/ΔE of order 10 000 and spatial resolution better than 10 μm. Initial tests of the high resolution instrument on HEDP plasmas are being performed.

  17. Wide-band, high-resolution soft x-ray spectrometer for the Electron Beam Ion Trap

    SciTech Connect

    Brown, G.V.; Beiersdorfer, P.; Widmann, K.

    1999-01-01

    We have constructed two wide-band, high-resolution vacuum flat crystal spectrometers and implemented them on the Electron Beam Ion Trap located at the Lawrence Livermore National Laboratory. Working in unison, these spectrometers can measure an x-ray bandwidth {le}9 {Angstrom} in the soft x-ray region below 21 {Angstrom}. In order to achieve this large bandwidth each spectrometer houses either two 125 mm {times} 13 mm {times} 2 mm RAP (rubidium acid phthalate, 2d=26.121 {Angstrom}), two 114 mm {times} 13 mm {times} 2 mm TlAP (thallium acid phthalate, 2d=25.75 {Angstrom}) crystals, or some combination thereof, for dispersion and two position sensitive proportional counters for detection of x rays. The spectrometers are used to measure wavelengths and relative intensities of the L-shell line emission from FethinspXVII{endash}XXIV for comparison with spectra obtained from astrophysical and laboratory plasmas. The wide wavelength coverage attainable by these spectrometers makes it possible to measure all the L-shell emission from a given iron ion species simultaneously. {copyright} {ital 1999 American Institute of Physics.}

  18. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    NASA Astrophysics Data System (ADS)

    Fuchs, O.; Weinhardt, L.; Blum, M.; Weigand, M.; Umbach, E.; Bär, M.; Heske, C.; Denlinger, J.; Chuang, Y.-D.; McKinney, W.; Hussain, Z.; Gullikson, E.; Jones, M.; Batson, P.; Nelles, B.; Follath, R.

    2009-06-01

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as (30×3000) μm2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min.

  19. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    SciTech Connect

    Fuchs, Oliver; Weinhardt, L.; Blum, M.; Weigand, M.; Umbach, E.; Bar, M.; Heske, Clemens; Denlinger, Jonathan; Chuang, Y.-D.; McKinney, Wayne; Hussain, Zahid; Gullikson, Eric; Jones, M.; Batson, Phil; Nelles, B.; Follath, R.

    2009-03-09

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as 30x3000 mu m2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min.

  20. Qualification of a high-efficiency, gated spectrometer for x-ray Thomson scattering on the National Ignition Facility

    SciTech Connect

    Döppner, T.; Kritcher, A. L.; Bachmann, B.; Burns, S.; Hawreliak, J.; House, A.; Landen, O. L.; LePape, S.; Ma, T.; Pak, A.; Swift, D.; Neumayer, P.; Kraus, D.; Falcone, R. W.; Glenzer, S. H.

    2014-11-15

    We have designed, built, and successfully fielded a highly efficient and gated Bragg crystal spectrometer for x-ray Thomson scattering measurements on the National Ignition Facility (NIF). It utilizes a cylindrically curved Highly Oriented Pyrolytic Graphite crystal. Its spectral range of 7.4–10 keV is optimized for scattering experiments using a Zn He-α x-ray probe at 9.0 keV or Mo K-shell line emission around 18 keV in second diffraction order. The spectrometer has been designed as a diagnostic instrument manipulator-based instrument for the NIF target chamber at the Lawrence Livermore National Laboratory, USA. Here, we report on details of the spectrometer snout, its novel debris shield configuration and an in situ spectral calibration experiment with a Brass foil target, which demonstrated a spectral resolution of E/ΔE = 220 at 9.8 keV.

  1. FRONT-END ASIC FOR HIGH RESOLUTION X-RAY SPECTROMETERS.

    SciTech Connect

    DE GERONIMO,G.; CHEN, W.; FRIED, J.; LI, Z.; PINELLI, D.A.; REHAK, P.; VERNON, E.; GASKIN, J.A.; RAMSEY, B.D.; ANELLI, G.

    2007-10-27

    We present an application specific integrated circuit (ASIC) for high-resolution x-ray spectrometers. The ASIC is designed to read out signals from a pixelated silicon drift detector (SDD). Each hexagonal pixel has an area of 15 mmz and an anode capacitance of less than 100 fF. There is no integrated Field Effect transistor (FET) in the pixel, rather, the readout is done by wirebonding the anodes to the inputs of the ASIC. The ASIC provides 14 channels of low-noise charge amplification, high-order shaping with baseline stabilization, and peak detection with analog memory. The readout is sparse and based on low voltage differential signaling. An interposer provides all the interconnections required to bias and operate the system. The channel dissipates 1.6 mW. The complete 14-pixel unit covers an area of 210 mm{sup 2}, dissipates 12 mW cm{sup -2}, and can be tiled to cover an arbitrarily large detection area. We measured a preliminary resolution of 172 eV at -35 C on the 6 keV peak of a {sup 55}Fe source.

  2. [Technology Development for X-Ray Reflection for the Constellation-X Reflection Grating Spectrometer (RGS)

    NASA Technical Reports Server (NTRS)

    Schattenburg, Mark L.

    2003-01-01

    This Grant covers MIT support for the technology development of x-ray reflection gratings for the Constellation-X Reflection Grating Spectrometer (RGS). Since the start of the Grant MIT has extended its previously-developed patterning and super-smooth, blazed grating fabrication technology to ten-times smaller grating periods and ten-times larger blaze angles to demonstrate feasibility and performance in the off-plane grating geometry. In the past year we successfully developed several nanoimprint grating replication methods that achieved very high fidelity replication of master silicon gratings. Grating geometry on the nano and macro scales were faithfully replicated, demonstrating the viability of the process for manufacturing the thousands of gratings required for the RGS. We also successfully developed an improved metrology truss for holding test grating substrates during metrology. The flatness goal of grating substrates is under 500 nm. In the past, grating holders would cause non-repeatable distortion of >> 500 nm to the substrates due to friction and gravity sag. The new holder has a repeatability of under 50 nm which is adequate for the proposed RGS grating substrates.

  3. Chemical heterogeneity on Mercury's surface revealed by the MESSENGER X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Weider, Shoshana Z.; Nittler, Larry R.; Starr, Richard D.; McCoy, Timothy J.; Stockstill-Cahill, Karen R.; Byrne, Paul K.; Denevi, Brett W.; Head, James W.; Solomon, Sean C.

    2012-10-01

    We present the analysis of 205 spatially resolved measurements of the surface composition of Mercury from MESSENGER's X-Ray Spectrometer. The surface footprints of these measurements are categorized according to geological terrain. Northern smooth plains deposits and the plains interior to the Caloris basin differ compositionally from older terrain on Mercury. The older terrain generally has higher Mg/Si, S/Si, and Ca/Si ratios, and a lower Al/Si ratio than the smooth plains. Mercury's surface mineralogy is likely dominated by high-Mg mafic minerals (e.g., enstatite), plagioclase feldspar, and lesser amounts of Ca, Mg, and/or Fe sulfides (e.g., oldhamite). The compositional difference between the volcanic smooth plains and the older terrain reflects different abundances of these minerals and points to the crystallization of the smooth plains from a more chemically evolved magma source. High-degree partial melts of enstatite chondrite material provide a generally good compositional and mineralogical match for much of the surface of Mercury. An exception is Fe, for which the low surface abundance on Mercury is still higher than that of melts from enstatite chondrites and may indicate an exogenous contribution from meteoroid impacts.

  4. Chemical Heterogeneity on Mercury's Surface Revealed by the MESSENGER X-ray Spectrometer

    NASA Technical Reports Server (NTRS)

    Weider, Shoshana Z.; Nittler, Larry R.; Starr, Richard D.; McCoy, Timothy J.; Stockstill-Cahill, Karen R.; Byrne, Paul K.; Denevi, Brett W.; Head, James W.; Solomon, Sean C.

    2012-01-01

    We present the analysis of 205 spatially resolved measurements of the surfacecomposition of Mercury from MESSENGERs X-Ray Spectrometer. The surfacefootprints of these measurements are categorized according to geological terrain. Northernsmooth plains deposits and the plains interior to the Caloris basin differ compositionallyfrom older terrain on Mercury. The older terrain generally has higher MgSi, SSi, andCaSi ratios, and a lower AlSi ratio than the smooth plains. Mercurys surface mineralogyis likely dominated by high-Mg mafic minerals (e.g., enstatite), plagioclase feldspar, andlesser amounts of Ca, Mg, andor Fe sulfides (e.g., oldhamite). The compositionaldifference between the volcanic smooth plains and the older terrain reflects differentabundances of these minerals and points to the crystallization of the smooth plains from amore chemically evolved magma source. High-degree partial melts of enstatite chondritematerial provide a generally good compositional and mineralogical match for much ofthe surface of Mercury. An exception is Fe, for which the low surface abundance onMercury is still higher than that of melts from enstatite chondrites and may indicate anexogenous contribution from meteoroid impacts.

  5. SPECTRAL SURVEY OF X-RAY BRIGHT ACTIVE GALACTIC NUCLEI FROM THE ROSSI X-RAY TIMING EXPLORER

    SciTech Connect

    Rivers, Elizabeth; Markowitz, Alex; Rothschild, Richard

    2011-03-15

    Using long-term monitoring data from the Rossi X-ray Timing Explorer (RXTE), we have selected 23 active galactic nuclei (AGNs) with sufficient brightness and overall observation time to derive broadband X-ray spectra from 3 to {approx}>100 keV. Our sample includes mainly radio-quiet Seyferts, as well as seven radio-loud sources. Given the longevity of the RXTE mission, the greater part of our data is spread out over more than a decade, providing truly long-term average spectra and eliminating inconsistencies arising from variability. We present long-term average values of absorption, Fe line parameters, Compton reflection strengths, and photon indices, as well as fluxes and luminosities for the hard and very hard energy bands, 2-10 keV and 20-100 keV, respectively. We find tentative evidence for high-energy rollovers in three of our objects. We improve upon previous surveys of the very hard X-ray energy band in terms of accuracy and sensitivity, particularly with respect to confirming and quantifying the Compton reflection component. This survey is meant to provide a baseline for future analysis with respect to the long-term averages for these sources and to cement the legacy of RXTE, and especially its High Energy X-ray Timing Experiment, as a contributor to AGN spectral science.

  6. On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

    NASA Technical Reports Server (NTRS)

    Champey, Patrick; Winebarger, Amy; Kobayashi, Ken; Savage, Sabrina; Cirtain, Jonathan; Cheimets, Peter; Hertz, Edward; Golub, Leon; Ramsey, Brian; McCracken, Jeff

    2016-01-01

    The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

  7. The spectral archive of cosmic X-ray sources observed by the Einstein Observatory Focal Plane Crystal Spectrometer

    NASA Technical Reports Server (NTRS)

    Lum, Kenneth S. K.; Canizares, Claude R.; Clark, George W.; Coyne, Joan M.; Markert, Thomas H.; Saez, Pablo J.; Schattenburg, Mark L.; Winkler, P. F.

    1992-01-01

    The Einstein Observatory Focal Plane Crystal Spectrometer (FPCS) used the technique of Bragg spectroscopy to study cosmic X-ray sources in the 0.2-3 keV energy range. The high spectral resolving power (E/Delta-E is approximately equal to 100-1000) of this instrument allowed it to resolve closely spaced lines and study the structure of individual features in the spectra of 41 cosmic X-ray sources. An archival summary of the results is presented as a concise record the FPCS observations and a source of information for future analysis by the general astrophysics community. For each observation, the instrument configuration, background rate, X-ray flux or upper limit within the energy band observed, and spectral histograms are given. Examples of the contributions the FPCS observations have made to the understanding of the objects observed are discussed.

  8. Integrated X-ray testing of the electro-optical breadboard model for the XMM reflection grating spectrometer

    SciTech Connect

    Bixler, J.V.; Craig, W.; Decker, T.; Aarts, H.; Boggende, T. den; Brinkman, A.C.; Burkert, W.; Brauninger, H.; Branduardi-Raymont, G.; Dubbeldam, L.

    1994-07-12

    X-ray calibration of the Electro-Optical Breadboard Model (EOBB) of the XXM Reflection Grating Spectrometer has been carried out at the Panter test facility in Germany. The EOBB prototype optics consisted of a four-shell grazing incidence mirror module followed by an array of eight reflection gratings. The dispersed x-rays were detected by an array of three CCDs. Line profile and efficiency measurements where made at several energies, orders, and geometric configurations for individual gratings and for the grating array as a whole. The x-ray measurements verified that the grating mounting method would meet the stringent tolerances necessary for the flight instrument. Post EOBB metrology of the individual gratings and their mountings confirmed the precision of the grating boxes fabrication. Examination of the individual grating surface`s at micron resolution revealed the cause of anomalously wide line profiles to be scattering due to the crazing of the replica`s surface.

  9. High-sensitivity, portable, tunable imaging X-ray spectrometer based on a spherical crystal and MCP

    NASA Astrophysics Data System (ADS)

    Monot, P.; Auguste, T.; Dobosz, S.; D'Oliveira, P.; Hulin, S.; Bougeard, M.; Faenov, A. Ya.; Pikuz, T. A.; Skobelev, I. Yu.

    2002-05-01

    A portable (200×100×100 mm 3), high-luminosity, spherically bent crystal spectrometer was designed to measure very low emissivity X-ray spectra of different elements with spatial resolution in a wide spectral range (1.2-19.6 Å). A large (50×15 mm 2) open aperture mica spherically bent crystal with R=150 mm was used as dispersive and focusing element. This spectrometer was associated with a large sensitive area ( φ=40 mm) micro-channel plates assembly. This apparatus provides simultaneously high spectral ( λ/ δλ˜1800) and spatial (100-200 μm) resolutions. Its large tunability allowed, without any adjustment of the spectrometer set-up, to record spectra in the 1.38-17.5 Å wavelength range. We used the X-ray emission of femtosecond laser-produced plasmas from different materials ((CF 2) n, CaF 2, Cu, Al) to test the spectrometer. Thanks to the high sensitivity (high collection efficiency) of the system, high quality space-resolved X-ray spectra of Fluorine and Aluminum plasmas were obtained on a single laser shot.

  10. Soft X-Ray (1-7 nm) Solar Spectrometer based on novel Nanowriter Electron-Beam Nanofabrication Technology

    NASA Astrophysics Data System (ADS)

    Didkovsky, L. V.; Wieman, S. R.; Chao, W.

    2015-12-01

    A new soft X-ray (SXR) spectrometer combines proven detector technology demonstrated on the SOHO Solar EUV Monitor (SOHO/SEM) and SDO EUV SpectroPhotometer (SDO/EVE/ESP) instruments with novel technology for X-ray optics nanofabrication developed at the Lawrence Berkeley National Laboratory. The new spectrometer will provide solar SXR measurements of absolute irradiance in the 1.0 to 7.0 nm range spectrally resolved into bands narrower than 1 nm - measurements that are not available from existing solar-observing instruments but are important for studying and modeling coronal dynamics and the Sun-Earth's connection, e.g. the Earth's Ionosphere. For the proposed SXR spectrometer we will introduce a transmission grating based on novel Nanowriter Electron-Beam Nanofabrication technology developed at the Center for X-ray Optics (CXRO) at the Lawrence Berkeley National Laboratory. The CXRO technology has been used in the fabrication of X-ray zone plates with feature sizes as small as 25 nm in optical elements with overall sizes on the order of 1 cm. The CXRO technology has significant flexibility in terms of pattern geometry, and is thus capable of producing linear transmission gratings with aperture sizes similar to SEM and ESP but with four times the dispersion. With such dispersion, reasonable spectral resolution (< 1nm) can be obtained using commercial off-the shelf (COTS) X-ray sensitive AXUV type silicon photodiodes from the Optodiode Corp. in an instrument with overall size and mass similar to that of SEM or ESP.

  11. Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

    NASA Technical Reports Server (NTRS)

    Hampton, Michael D.

    2002-01-01

    The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

  12. High-pressure duo-multichannel soft x-ray spectrometer for tokamak plasma diagnostics

    SciTech Connect

    Schwob, J.L.; Wouters, A.W.; Suckewer, S.

    1987-03-01

    A high-resolution, time-resolving soft X-ray multichannel spectrometer (SOXMOS) that permits the simultaneous measurement of emission in two different spectral ranges has been developed and tested extensively for tokamak plasma diagnostics. The basic instrument is a high-resolution, interferometrically adjusted, extreme grazing incidence Schwob-Fraenkel duochromator. The instrument is equipped with two multichannel detectors that are adjusted interferometrically and scan along the Rowland circle. Each consists of an MgF/sub 2/ coated, funneled microchannel plate, associated with a phosphor screen image intensifier that is coupled to a 1024-element photodiode array by a flexible fibrer optic conduit. The total wavelength coverage of the instrument is 5 to 340/sup 0/ A with a measured resolution (FWHM) of about 0.2 A when equipped with a 600 g/mm grating, and 5 to 85 A with a resolution of about 0.06 A using a 2400 g/mm grating. The simultaneous spectral coverage of each detector varies from 15 A at the short wavelength limit to 70 A at the long wavelength limit with the lower dispersion grating. The minimum read-out time for a full spectral portion is 17 ms, but several individual lines can be measured with 1 ms time resolution by selected pixel readout. Higher time resolution can be achieved by replacing one multichannel detector with a single channel electron multiplier detector. Examples of data from the PLT and TFTR tokamaks are presented to illustrate the instrument's versatility, high spectral resolution, and high signal-to-noise ratio even in the 10 A region. 44 refs., 20 figs.

  13. A broadband high-resolution elliptical crystal x-ray spectrometer for high energy density physics experiments

    SciTech Connect

    Anderson, S G; Heeter, R F; Booth, R; Emig, J; Fulkerson, S; McCarville, T; Norman, D; Young, B F

    2006-03-31

    Spectroscopic investigation of high temperature laser produced plasmas in general, and x-ray opacity experiments in particular, often requires instruments with both a broad coverage of x-ray energies and high spectral, spatial, and temporal resolution. We analyze the design, model the response, and report the commissioning of a spectrometer using elliptical crystals in conjunction with a large format, gated microchannel plate detector. Measurements taken with this instrument at the JANUS laser facilities demonstrate the designed spectral range of 0.24 to 5.8 keV, and spectral resolution E/{Delta}E > 500, resulting in 2 to 3 times more spectral data than achieved by previous spectrometer designs. The observed 100 picosecond temporal resolution and 35 {micro}m spatial resolution are consistent with the requirements of high energy density opacity experiments.

  14. Clumpy tori around type II active galactic nuclei as revealed by X-ray fluorescent lines

    NASA Astrophysics Data System (ADS)

    Liu, Jiren; Liu, Yuan; Li, Xiaobo; Xu, Weiwei; Gou, Lijun; Cheng, Cheng

    2016-06-01

    The reflection spectrum of a torus around an active galactic nucleus (AGN) is characterized by X-ray fluorescent lines, which are most prominent for type II AGNs. A clumpy torus allows photons reflected from the back-side of the torus to leak through the front regions that are free of obscuration. The observed X-ray fluorescent lines are therefore sensitive to the clumpiness of the torus. We analysed a sample of type II AGNs observed with the Chandra High Energy Transmission Grating Spectrometer (HETGS), and measured the fluxes for the Si Kα and Fe Kα lines. The measured Fe Kα/Si Kα ratios, spanning a range between 5 and 60, are far smaller than the ratios predicted from simulations of smooth tori, indicating that the tori of the studied sources have clumpy distributions rather than smooth ones. We compared the measured Fe Kα/Si Kα ratios with simulation results of clumpy tori. The Circinus galaxy has a Fe Kα/Si Kα ratio of ˜60, which is close to the simulation results for N = 5, where N is the average number of clumps along the line of sight. The Fe Kα/Si Kα ratios of the other sources are all below the simulation results for N = 2. Overall, this shows that the non-Fe fluorescent lines in the soft X-ray band are a potentially powerful probe of the clumpiness of tori around AGNs.

  15. Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST.

    PubMed

    Lyu, B; Wang, F D; Pan, X Y; Chen, J; Fu, J; Li, Y Y; Bitter, M; Hill, K W; Delgado-Aparicio, L F; Pablant, N; Lee, S G; Shi, Y J; Ye, M Y; Wan, B N

    2014-11-01

    Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm(2), a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

  16. Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST

    SciTech Connect

    Lyu, B. Wang, F. D.; Fu, J.; Li, Y. Y.; Pan, X. Y.; Chen, J.; Wan, B. N.; Bitter, M.; Hill, K. W.; Delgado-Aparicio, L. F.; Pablant, N.; Lee, S. G.; Shi, Y. J.; Ye, M. Y.

    2014-11-15

    Upgrade of the imaging X-ray crystal spectrometers continues in order to fulfill the high-performance diagnostics requirements on EAST. For the tangential spectrometer, a new large pixelated two-dimensional detector was deployed on tokamaks for time-resolved X-ray imaging. This vacuum-compatible detector has an area of 83.8 × 325.3 mm{sup 2}, a framing rate over 150 Hz, and water-cooling capability for long-pulse discharges. To effectively extend the temperature limit, a double-crystal assembly was designed to replace the previous single crystals for He-like argon line measurement. The tangential spectrometer employed two crystal slices attached to a common substrate and part of He- and H-like Ar spectra could be recorded on the same detector when crystals were chosen to have similar Bragg angles. This setup cannot only extend the measurable Te up to 10 keV in the core region, but also extend the spatial coverage since He-like argon ions will be present in the outer plasma region. Similarly, crystal slices for He-like iron and argon spectra were adopted on the poloidal spectrometer. Wavelength calibration for absolute rotation velocity measurement will be studied using cadmium characteristic L-shell X-ray lines excited by plasma radiation. A Cd foil is placed before the crystal and can be inserted and retracted for in situ wavelength calibration. The Geant4 code was used to estimate X-ray fluorescence yield and optimize the thickness of the foil.

  17. Objectives and Layout of a High-Resolution X-ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)

    SciTech Connect

    Bitter, M; Gates, D; Monticello, D; Neilson, H; Reiman, A; Roquemore, A L; Morita, S; Goto, M; Yamada, H

    2010-07-29

    A high-resolution X-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for LHD. This instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of < 2 cm and ≥ 10 ms. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD.

  18. An X-ray fluorescence spectrometer and its applications in materials studies

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Han, K. S.

    1977-01-01

    An X-ray fluorescence system based on a Co(57) gamma-ray source has been developed. The system was used to calculate the atomic percentages of iron implanted in titanium targets. Measured intensities of Fe (k-alpha + k-beta) and Ti (k-alpha + k-beta) X-rays from the Fe-Ti targets are in good agreement with the calculated values based on photoelectric cross sections of Ti and Fe for the Co(57) gamma rays.

  19. X-ray color analysis of the spectra of active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Netzer, Hagai; Turner, T. J.; George, Ian M.

    1994-01-01

    The identification and detection of X-ray absorption and emission features depends on the resolution and the signal-to-noise ratio (S/N) of the observation, the understanding of the instrument response, and the Galactic line-of-sight absorption. Since many of the active galactic nucleus (AGN) data sets are limited in their S/N and full modeling of the physical conditions is rather complicated, we suggest a new analysis method based on 'X-ray colors.' The two sets of X-ray colors, defined for low (ROSAT Position Sensitive Proportional Counter (PSPC)) and medium (Broad Band X-Ray Telescope (BBXRT)) and ASCA Solid-State Imaging Spectrometers (SIS) resolution experiments, are used to separate regions of different physical conditions in a two-dimensional color-color plane. They are similar but superior to previous methods using the X-ray 'hardness ratio' in being able to reveal more of the physical properties of the source. We illustrate the use of such diagrams by studying a number of AGNs suspected of showing absorption features. A sample of 14 AGNs observed by the ROSAT PSPC is presented which includes several objects with suspected 'warm absorbers' along the line-of-sight to the nucleus, several others exhibiting intrinsic continuum variations, and a number of control objects thought to be featureless. Our new observations show, for the first time, the color variation as a function of time for three of the Seyfert 1 sources: NGC 4051, Mrk 335, and Mrk 766. The variations suggest that in two sources we are witnessing real changes in continuum shape, while one (NGC 4051) is consistent with having a warm absorber. Four of the objects observed by BBXRT are reanalyzed using our X-ray colors. Out of these, we discuss in detail the case of NGC 4151 and show that the color-color analysis agrees very well with previous, detailed spectral fitting methods. In particular, we confirm that the observed BBXRT observation of this source is not consistent with the warm absorber

  20. Resonant inelastic X-ray scattering spectrometer with 25 meV resolution at the Cu K-edge.

    PubMed

    Ketenoglu, Didem; Harder, Manuel; Klementiev, Konstantin; Upton, Mary; Taherkhani, Mehran; Spiwek, Manfred; Dill, Frank Uwe; Wille, Hans Christian; Yavaş, Hasan

    2015-07-01

    An unparalleled resolution is reported with an inelastic X-ray scattering instrument at the Cu K-edge. Based on a segmented concave analyzer, featuring single-crystal quartz (SiO₂) pixels, the spectrometer delivers a resolution near 25 meV (FWHM) at 8981 eV. Besides the quartz analyzer, the performance of the spectrometer relies on a four-bounce Si(553) high-resolution monochromator and focusing Kirkpatrick-Baez optics. The measured resolution agrees with the ray-tracing simulation of an ideal spectrometer. The performance of the spectrometer is demonstrated by reproducing the phonon dispersion curve of a beryllium single-crystal. PMID:26134800

  1. Resonant inelastic X-ray scattering spectrometer with 25 meV resolution at the Cu K-edge

    PubMed Central

    Ketenoglu, Didem; Harder, Manuel; Klementiev, Konstantin; Upton, Mary; Taherkhani, Mehran; Spiwek, Manfred; Dill, Frank-Uwe; Wille, Hans-Christian; Yavaş, Hasan

    2015-01-01

    An unparalleled resolution is reported with an inelastic X-ray scattering instrument at the Cu K-edge. Based on a segmented concave analyzer, featuring single-crystal quartz (SiO2) pixels, the spectrometer delivers a resolution near 25 meV (FWHM) at 8981 eV. Besides the quartz analyzer, the performance of the spectrometer relies on a four-bounce Si(553) high-resolution monochromator and focusing Kirkpatrick–Baez optics. The measured resolution agrees with the ray-tracing simulation of an ideal spectrometer. The performance of the spectrometer is demonstrated by reproducing the phonon dispersion curve of a beryllium single-crystal. PMID:26134800

  2. Elemental Analysis of the Surface of Comet 67p/Churyumov-Gerasimenko with the Alpha Particle X-Ray Spectrometer APXS on the Rosetta Lander Philae: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Klingelhoefer, G.; Schmanke, D.; Girones-Lopez, J.; Brueckner, J.; d'Uston, C.; Economou, T.; Gellert, R.; Markovski, C.

    2014-12-01

    After a 10 years cruise the Rosetta probe has reached its final target, the comet 67P/Churyumov-Gerasimenko. The main objectives of the mission are to gain more knowledge of the composition, the origin and formation of comets and the solar system. After extensive remote exploration of the comet the lander Philae will be separated to land on the comet surface, starting immediately examining its landing site with its scientific payload. Part of this payload is the APXS (Alpha Particle X-Ray Spectrometer). It will measure in situ the chemical composition of the comet's surface and it's changes during the journey of the comet towards the sun. APXS is a combination of two spectrometers in one single instrument. It will irradiate the comet surface using Curium 244 sources, which are emitting alpha-particle and X-rays. In the alpha-mode the instrument uses alpha backscattering spectroscopy to detect lower Z elements like C, N and O and groups of elements with higher Z. In the X-ray mode alpha particle / X-ray induced X-ray spectroscopy (XRF) will allow the detection of most of the higher Z elements from Na up to Ni and above. Both modes will be always run in parallel allowing to determine lower and higher Z elements simultaneously. For 3 years the solar powered Rosetta probe had to pass a hibernation phase because of a long passage far away to the sun. After wakeup in January 2014 an extensive test phase of all instruments and subsystems has been performed, including the APXS. After landing on the comet an intense initial measurement phase of all instruments is planned, the First Science Sequence (FSS). It will be followed by a long term science phase (LTS). As long as possible APXS and the other instruments will continue to measure and monitor the changes and increasing activity of the comet during its journey towards the inner region of the solar system.The project is funded by the German Space Agency DLR under contracts 50 QP 0404 and 50 QP 0902. References: G

  3. GSFC Contributions to the NATO X-ray Astronomy Institute, Erice, July 1979. [X-ray spectra of supernova remants, galactic X-ray sources, active galactic nuclei, and clusters of galaxies

    NASA Technical Reports Server (NTRS)

    Holt, S. S.; Mushotzky, R. F.

    1979-01-01

    An overview of X-ray astronomical spectroscopy in general is presented and results obtained by HEAO 1 and 2 as well as earlier spacecraft are examined. Particular emphasis is given to the spectra of supernova remnants; galactic binary X-ray sources, cataclysmic variables, bulges, pulsars, and stars; the active nuclei of Seyfert 1 galaxy, BL Lac, and quasars; the diffuse X-ray background; and galactic clusters.

  4. Imaging crystal spectrometer for high-resolution x-ray measurements on electron beam ion traps and tokamaks

    NASA Astrophysics Data System (ADS)

    Beiersdorfer, P.; Magee, E. W.; Hell, N.; Brown, G. V.

    2016-11-01

    We describe a crystal spectrometer implemented on the Livermore electron beam ion traps that employ two spherically bent quartz crystals and a cryogenically cooled back-illuminated charge-coupled device detector to measure x rays with a nominal resolving power of λ/Δλ ≥ 10 000. Its focusing properties allow us to record x rays either with the plane of dispersion perpendicular or parallel to the electron beam and, thus, to preferentially select one of the two linear x-ray polarization components. Moreover, by choice of dispersion plane and focussing conditions, we use the instrument either to image the distribution of the ions within the 2 cm long trap region, or to concentrate x rays of a given energy to a point on the detector, which optimizes the signal-to-noise ratio. We demonstrate the operation and utility of the new instrument by presenting spectra of Mo34+, which prepares the instrument for use as a core impurity diagnostic on the NSTX-U spherical torus and other magnetic fusion devices that employ molybdenum as plasma facing components.

  5. Mapping Mercury's Surface Composition at High Spatial Resolution with the MESSENGER X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Nittler, L. R.; Weider, S. Z.; Starr, R. D.; Vorburger, A.; Solomon, S. C.

    2014-12-01

    Previous global maps of Mg/Si and Al/Si and partial maps of S/Si, Ca/Si, and Fe/Si on Mercury's surface derived from orbital data acquired by the MESSENGER X-Ray Spectrometer (XRS) have been highly variable in resolution because of MESSENGER's eccentric orbit and high northern periapsis. The typical spatial resolution at northern latitudes in earlier maps was 200-500 km, a scale that allowed large geochemical terranes to be defined and chemical measurements to be made of features hundreds of kilometers in extent, but so far there have been very few analyses at smaller scales. MESSENGER is now orbiting at the lowest periapsis altitudes so far in the mission, and XRS measurements can thus be made at substantially improved resolution. For example, measurements with resolutions <100 km constituted 1% of the northern-hemisphere observations that were used to make the previous maps, but they make up 31% of those obtained in May and June of 2014. Preliminary analysis of these higher-resolution XRS data confirms the broad-scale geochemical features that have already been identified, but also reveals smaller-scale chemical heterogeneities. For instance, targeted XRS measurements indicate that the high-reflectance smooth plains deposit, about 125 km in extent, at the center of the Rachmaninoff basin has Mg/Si=0.6, higher than for other smooth plains deposits with similar reflectance characteristics (for which Mg/Si is typically <0.4), but similar to the darker material surrounding the unit. Although the high-resolution maps that we continue to generate have limited coverage, they reveal substantial chemical heterogeneity at the 100-km scale both within the northern volcanic plains and within the large high-Mg region that has been previously identified. In many cases, the chemical heterogeneity we observe is closely associated with spatial variations in spectral reflectance properties. Continued observations at ever lower altitudes will allow chemical mapping on Mercury at

  6. The Corona of HD 189733 and its X-Ray Activity

    NASA Astrophysics Data System (ADS)

    Pillitteri, I.; Wolk, S. J.; Lopez-Santiago, J.; Günther, H. M.; Sciortino, S.; Cohen, O.; Kashyap, V.; Drake, J. J.

    2014-04-01

    Testing whether close-in massive exoplanets (hot Jupiters) can enhance the stellar activity in their host primary is crucial for the models of stellar and planetary evolution. Among systems with hot Jupiters, HD 189733 is one of the best studied because of its proximity, strong activity, and the presence of a transiting planet, which allows transmission spectroscopy and a measure of the planetary radius and its density. Here we report on the X-ray activity of the primary star, HD 189733 A, using a new XMM-Newton observation and a comparison with the previous X-ray observations. The spectrum in the quiescent intervals is described by two temperatures at 0.2 keV and 0.7 keV, while during the flares a third component at 0.9 keV is detected. With the analysis of the summed Reflection Grating Spectrometer spectra, we obtain estimates of the electron density in the range ne = (1.6-13) × 1010 cm-3, and thus the corona of HD 189733 A appears denser than the solar one. For the third time, we observe a large flare that occurred just after the eclipse of the planet. Together with the flares observed in 2009 and 2011, the events are restricted to a small planetary phase range of phi = 0.55-0.65. Although we do not find conclusive evidence of a significant excess of flares after the secondary transits, we suggest that the planet might trigger such flares when it passes close to the locally high magnetic field of the underlying star at particular combinations of stellar rotational phases and orbital planetary phases. For the most recent flares, a wavelet analysis of the light curve suggests a loop of length of four stellar radii at the location of the bright flare, and a local magnetic field of the order of 40-100 G, in agreement with the global field measured in other studies. The loop size suggests an interaction of magnetic nature between planet and star, separated by only ~8R *. The X-ray variability of HD 189733 A is larger than the variability of field stars and young

  7. Development of a spatially resolving x-ray crystal spectrometer for measurement of ion-temperature (T(i)) and rotation-velocity (v) profiles in ITER.

    PubMed

    Hill, K W; Bitter, M; Delgado-Aparicio, L; Johnson, D; Feder, R; Beiersdorfer, P; Dunn, J; Morris, K; Wang, E; Reinke, M; Podpaly, Y; Rice, J E; Barnsley, R; O'Mullane, M; Lee, S G

    2010-10-01

    Imaging x-ray crystal spectrometer (XCS) arrays are being developed as a US-ITER activity for Doppler measurement of T(i) and v profiles of impurities (W, Kr, and Fe) with ∼7 cm (a/30) and 10-100 ms resolution in ITER. The imaging XCS, modeled after a prototype instrument on Alcator C-Mod, uses a spherically bent crystal and 2D x-ray detectors to achieve high spectral resolving power (E/dE>6000) horizontally and spatial imaging vertically. Two arrays will measure T(i) and both poloidal and toroidal rotation velocity profiles. The measurement of many spatial chords permits tomographic inversion for the inference of local parameters. The instrument design, predictions of performance, and results from C-Mod are presented.

  8. New reference and test materials for the characterization of energy dispersive X-ray spectrometers at scanning electron microscopes.

    PubMed

    Rackwitz, Vanessa; Krumrey, Michael; Laubis, Christian; Scholze, Frank; Hodoroaba, Vasile-Dan

    2015-04-01

    Checking the performance of energy dispersive X-ray spectrometers as well as validation of the results obtained with energy dispersive X-ray spectrometry (EDX) at a scanning electron microscope (SEM) involve the use of (certified) reference and dedicated test materials. This paper gives an overview on the test materials mostly employed by SEM/EDX users and accredited laboratories as well as on those recommended in international standards. The new BAM reference material EDS-CRM, which is currently in the process of certification, is specifically designed for the characterization of EDS systems at a SEM through calibration of the spectrometer efficiency in analytical laboratories in a simple manner. The certification of the spectra by means of a reference EDS is described. The focus is on the traceability of EDS efficiency which is ensured by measurements of the absolute detection efficiency of silicon drift detectors (SDD) and Si(Li) detectors at the laboratory of the PTB using the electron storage ring BESSY II as a primary X-ray source standard. A new test material in development at BAM for testing the performance of an EDS in the energy range below 1 keV is also briefly presented.

  9. Thermodynamic performance of the 3-stage ADR for the Astro-H Soft-X-ray Spectrometer instrument

    NASA Astrophysics Data System (ADS)

    Shirron, Peter J.; Kimball, Mark O.; James, Bryan L.; Muench, Theodore; DiPirro, Michael J.; Bialas, Thomas G.; Sneiderman, Gary A.; Porter, Frederick S.; Kelley, Richard L.

    2016-03-01

    The Soft X-ray Spectrometer (SXS) instrument (Mitsuda et al., 2010) [1] on Astro-H (Takahashi et al., 2010) [2] will use a 3-stage ADR (Shirron et al., 2012) to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at ⩽1.20 K as the heat sink (Fujimoto et al., 2010). In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and single-shot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

  10. Thermodynamic Analysis of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

    NASA Technical Reports Server (NTRS)

    Shirron, Peter; Kimball, Mark; DiPirro, Michael; Bialas, Tom; Sneiderman, Gary; Porter, Scott; Kelley, Richard

    2015-01-01

    The Soft X-ray Spectrometer (SXS) instrument on Astro-H will use a 3-stage ADR to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at 1.20 K as the heat sink. In the secondary mode, which is activated when the liquid helium is depleted, two of the stages continuously cool the (empty) helium tank using a 4.5 K Joule-Thomson cooler as the heat sink, and the third stage cools the detectors. In the design phase, a high-fidelity model of the ADR was developed in order to predict both the cooling capacity and heat rejection rates in both operating modes. The primary sources of heat flow are from the salt pills, hysteresis heat from the magnets and magnetic shields, and power dissipated by the heat switches. The flight instrument dewar, ADR, detectors and electronics were integrated in mid-2014 and have since undergone extensive performance testing, in part to validate the performance model. This paper will present the thermodynamic performance of the ADR, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

  11. Activation of oncogenes by radon progeny and x-rays

    SciTech Connect

    Ling, C.C.

    1990-01-01

    The overall goal of this proposal is to study the carcinogenic effect of both high and low LET radiation at the molecular level, utilizing techniques developed in molecular biology, cancer cell biology and radiation biology. The underlying assumption is that malignant transformation of normal cells is a multistep process requiring two or more molecular events in the genomic DNA. We hypothesize that radiation may induce such events in one or more steps of the multistep process. We will use in vitro models of transformation that reproduce the stepwise progression of normal cells toward the transformed phenotype and ask whether radiation can provide the necessary activating function at discrete steps along this path. Our strategy involves transfecting into normal primary cells a variety of cloned oncogenes that are known to supply only some of the functions necessary for full transformation. These partially transformed'' cells will be the targets for irradiation by x-rays and alpha particles. The results will provide the basis for assessing the ability of ionizing radiation to activate oncogenic functions that complement'' the oncogene already present in the transfected cells and produce the fully transformed phenotype. Progress is described. 121 refs.

  12. Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer

    DOEpatents

    Warburton, William K.; Hubbard, Bradley

    1999-01-01

    A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner's operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system.

  13. Method and apparatus for analog signal conditioner for high speed, digital x-ray spectrometer

    DOEpatents

    Warburton, W.K.; Hubbard, B.

    1999-02-09

    A signal processing system which accepts input from an x-ray detector-preamplifier and produces a signal of reduced dynamic range for subsequent analog-to-digital conversion is disclosed. The system conditions the input signal to reduce the number of bits required in the analog-to-digital converter by removing that part of the input signal which varies only slowly in time and retaining the amplitude of the pulses which carry information about the x-rays absorbed by the detector. The parameters controlling the signal conditioner`s operation can be readily supplied in digital form, allowing it to be integrated into a feedback loop as part of a larger digital x-ray spectroscopy system. 13 figs.

  14. Low energy X-ray spectra measured with a mercuric iodide energy dispersive spectrometer in a scanning electron microscope

    NASA Technical Reports Server (NTRS)

    Iwanczyk, J. S.; Dabrowski, A. J.; Huth, G. C.; Bradley, J. G.; Conley, J. M.

    1986-01-01

    A mercuric iodide energy dispersive X-ray spectrometer, with Peltier cooling provided for the detector and input field effect transistor, has been developed and tested in a scanning electron microscope. X-ray spectra were obtained with the 15 keV electron beam. An energy resolution of 225 eV (FWHM) for Mn-K(alpha) at 5.9 keV and 195 eV (FWHM) for the Mg-K line at 1.25 keV has been measured. Overall system noise level was 175 eV (FWHM). The detector system characterization with a carbon target demonstrated good energy sensitivity at low energies and lack of significant spectral artifacts at higher energies.

  15. First Results From The New High Resolution Imaging X-ray Crystal Spectrometer On Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Ince-Cushman, Alexander; Rice, John; Bitter, Manfred; Reinke, Mathew; Hill, Kenneth; Scott, Steven

    2007-11-01

    In an effort to improve the diagnostic capabilities for measuring plasma rotation on Alcator C-Mod, an imaging x-ray spectrometer has been designed and installed. This instrument utilizes a spherically bent quartz crystal and a set of 2D x-ray detectors to image the entire plasma cross section with a spectral resolving power of approximately 10,000 with vertical spatial resolution of about 1cm. Line emission from highly ionized states of argon and molybdenum are measured at frame rates up to 200Hz. Using spectral tomographic techniques the line integrated spectra can be inverted to determine impurity density, velocity and temperature profiles. An overview of the instrument, analysis and example profiles are presented. Work supported by USDoE Coop. Agree. No. DE-FC02-99ER54512 & DE-AC02-76CH03073.

  16. Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Döppner, T.; Kraus, D.; Neumayer, P.; Bachmann, B.; Emig, J.; Falcone, R. W.; Fletcher, L. B.; Hardy, M.; Kalantar, D. H.; Kritcher, A. L.; Landen, O. L.; Ma, T.; Saunders, A. M.; Wood, R. D.

    2016-11-01

    We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5-10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

  17. Low-cost virtual instrumentation system of an energy-dispersive X-ray spectrometer for a scanning electron microscope

    PubMed Central

    Lei, Junfeng; Zeng, Libo; Liu, Ronggui; Liu, Juntang; Zhang, Zelan

    2002-01-01

    The paper describes an energy-dispersive X-ray spectrometer for a scanning electron microscope (SEM-EDXS). It was constructed using the new architecture of a virtual instrument (VI), which is low-cost, space-saving, fast and flexible way to develop the instrument. Computer-aided teaching (CAT) was used to develop the instrument and operation rather than a traditional instrument technique. The VI was designed using the object-oriented program language C++ and compact programmable logical devices (CPLD). These include spectra collection and processing, quantitative analysis and X-ray-intensity distribution analysis. The procedure is described in detail. The VI system gives an e¡ective and user-friendly human interface for the whole analytical task. Some examples are described. PMID:18924732

  18. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    SciTech Connect

    Fuchs, Oliver; Weinhardt, L.; Blum, M.; Welgand, M.; Umbach, E.; Bar, M.; Heske, C.; Denlinger, J.; Chuang, Y.-D.; McKinney, W.; Hussain, Z.; Gullikson, E.; Jones, M.; Batson, P.; Nelles, B.; Follath, R.

    2009-06-11

    We present a variable line-space grating spectrometer for soft s-rays that coverst the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite is slitless design, such a resolving power can be achieved for a source spot as large as (30 x 3000) micrometers squared, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scatters (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken with 10 min.

  19. High-resolution X-ray spectroscopy of four active galaxies - Probing the intercloud medium

    NASA Astrophysics Data System (ADS)

    Lum, Kenneth S. K.; Canizares, Claude R.; Markert, Thomas H.; Arnaud, Keith A.

    1990-07-01

    The focal plane crystal spectrometer (FPCS) on the Einstein Observatory has been used to perform a high-resolution spectroscopic search for oxygen X-ray line emission from four active galaxies: Fairall 9, Mrk 421, Mrk 501, and PKS 0548 - 322. Specifically, O VIII Ly-alpha and Ly-beta, whose unredshifted energies are 653 and 775 eV, respectively, were sought. No narrow-line emission was detected within the energy bands searched. Upper limits are calculated on the line flux from these sources of 30 eV equivalent width and use a photoionization model to place corresponding upper limits on the densities of diffuse gas surrounding the active nuclei. The upper limits on gas density range from about 0.02-50/cu cm and probe various radial distances from the central source. This is the first time high-resolution X-ray spectroscopy has been used to place constraints on the intercloud medium in active galaxies.

  20. Fabricating sub-collimating grids for an x-ray solar imaging spectrometer using LIGA techniques

    SciTech Connect

    Brennen, R.A.; Hecht, M.H.; Wiberg, D.V.

    1997-04-01

    The HESSI mission proposes to perform high resolution imaging and spectroscopy observations in the soft X-ray, hard X-ray, and gamma-ray regimes, with finer angular resolution (nearly 2 arcseconds) and finer energy resolution (approximately 1 keV) than has been previously possible. This combination of imaging and spectroscopy is achieved with a set of Rotating Modulation Collimators placed in front of an array of cooled germanium and silicon detectors. A set of 12 bi-grid collimators, each of which consists of a pair of identically pitched, widely-separated grids, is used to provide the imaging. Each grid consists of a planar array of equally-spaced, parallel, X-ray opaque slats separated by X-ray transparent slits. If the slits of each grid are parallel to each other and the pitch is identical for the two grids, then the transmission through the grid pair depends on the direction of incidence of the incoming X-rays. For slits and slats of equal width, the transmission varies between zero and 50% depending on whether the shadows of the slats in the top grid fall on the slits or slats of the lower grid. A complete transmission cycle from zero to 50% and back to zero corresponds to a change in source direction that is given by p/L, where L is the separation between the grids. The authors describe a deep etch lithography technique developed to fabricate the grids which have pitches below 100 {micro}m. They use a free standing sheet of PMMA as a base for the process, and use the ALS facility to perform the exposures of the PMMA.

  1. Absolutely calibrated, time-resolved measurements of soft x rays using transmission grating spectrometers at the Nike Laser Facility

    NASA Astrophysics Data System (ADS)

    Weaver, J. L.; Feldman, U.; Seely, J. F.; Holland, G.; Serlin, V.; Klapisch, M.; Columbant, D.; Mostovych, A.

    2001-12-01

    Accurate simulation of pellet implosions for direct drive inertial confinement fusion requires benchmarking the codes with experimental data. The Naval Research Laboratory (NRL) has begun to measure the absolute intensity of radiation from laser irradiated targets to provide critical information for the radiatively preheated pellet designs developed by the Nike laser group. Two main diagnostics for this effort are two spectrometers incorporating three detection systems. While both spectrometers use 2500 lines/mm transmission gratings, one instrument is coupled to a soft x-ray streak camera and the other is coupled to both an absolutely calibrated Si photodiode array and a charge coupled device (CCD) camera. Absolute calibration of spectrometer components has been undertaken at the National Synchrotron Light Source at Brookhaven National Laboratories. Currently, the system has been used to measure the spatially integrated soft x-ray flux as a function of target material, laser power, and laser spot size. A comparison between measured and calculated flux for Au and CH targets shows reasonable agreement to one-dimensional modeling for two laser power densities.

  2. Bent crystal spectrometer for both frequency and wavenumber resolved x-ray scattering at a seeded free-electron laser

    SciTech Connect

    Zastrau, Ulf; Fletcher, Luke B.; Galtier, Eric Ch.; Gamboa, Eliseo; Glenzer, Siegfried H.; Heimann, Philipp; Nagler, Bob; Schropp, Andreas; Lee, Hae Ja; Förster, Eckhart; Marschner, Heike; Wehrhan, Ortrud

    2014-09-15

    We present a cylindrically curved GaAs x-ray spectrometer with energy resolution ΔE/E = 1.1 × 10{sup −4} and wave-number resolution of Δk/k = 3 × 10{sup −3}, allowing plasmon scattering at the resolution limits of the Linac Coherent Light Source (LCLS) x-ray free-electron laser. It spans scattering wavenumbers of 3.6 to 5.2/Å in 100 separate bins, with only 0.34% wavenumber blurring. The dispersion of 0.418 eV/13.5 μm agrees with predictions within 1.3%. The reflection homogeneity over the entire wavenumber range was measured and used to normalize the amplitude of scattering spectra. The proposed spectrometer is superior to a mosaic highly annealed pyrolytic graphite spectrometer when the energy resolution needs to be comparable to the LCLS seeded bandwidth of 1 eV and a significant range of wavenumbers must be covered in one exposure.

  3. Laboratory Tests of a Handheld X-Ray Fluorescence Spectrometer: A Tool for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Young, K. E.; Evans, C. A.; Hodges, K.

    2011-12-01

    Maximizing the science return from a mission to another planetary surface involves the integration of science objectives with deployable technologies that enable the collection of data and samples. For long duration manned missions, it is likely that more samples will be collected than can be returned to Earth due to mass limits. A niche exists for technologies that help prioritize samples for return, provide data for future sample handling and curation, and characterization for samples that are not returned to Earth. To fill this niche, hardware and protocols for field instruments are currently being developed and evaluated at NASA Johnson Space Center and Arizona State University. Our goal is to develop an easily used, environmentally isolated facility as part of the astronaut surface habitat for preliminary sample characterization and down-selection. NASA has constructed a prototype, GeoLab, as a testbed for evaluating the scientific applicability and operational considerations of various analytical instruments. One instrument under evaluation is a small, portable x-ray fluorescence (XRF) spectrometer that can be also be used by astronaut explorers as part of their field gear while on scientific sorties, or on robotic field assistants. We report on preliminary usability tests for commercially available handheld XRF instruments. These instruments collect data by contacting the surface of a rock or sediment sample with an 8 mm-wide sensor window. Within 60 seconds, the devices can provide relatively precise data on the abundance of major and trace elements heavier than Na. Lab-based handheld XRF analyses of terrestrial and lunar samples, compared with those made with full-scale laboratory XRF systems, show good correlation, but we continue to investigate potential sources of error and the need for careful calibration with standards of known composition. Specifically, we use a suite of five terrestrial and five lunar basalts, all well characterized by conventional

  4. Determination of 55Fe in waste waters of the Krsko nuclear power plant measured simultaneously by liquid scintillation spectrometer (LSC) and X-ray spectrometer (XRS)

    NASA Astrophysics Data System (ADS)

    Mikelic, L.; Orescanin, V.; Lulic, S.

    2007-10-01

    This paper presents comparison of two methods for the determination of 55Fe activity of waste waters discharged from the Krsko nuclear power plant (KNPP). Research was conducted on 12 composite samples of waste water collected in the waste monitor tank (WMT) during each month as well as on Analytics, Inc. cross-check sample. Results showed that the complicated and time-consuming method proposed by the Environmental Measurements Laboratory (EML) could be successfully replaced with a simple and fast based on the extraction of 55Fe from waste water by non-specific chelating agent ammonium-pyrrolidinedithiocarbamate (APDC) at pH 4 after separation from cobalt, and activity measurement by X-ray fluorescence spectroscopy (XRS). Results obtained by the XRS method were approximately 8.6% lower than those obtained by liquid scintillation spectrometer (LSC). The mean deviation of the XRS results from the activity of cross-check sample was 2.47%, which ensures that this method is accurate enough for environmental monitoring.

  5. Combined X-Ray and mm-Wave Observations of Radio Quiet Active Galaxies

    NASA Astrophysics Data System (ADS)

    Behar, E.

    2016-06-01

    A connection between the X-ray and radio sources in radio quiet active galaxies (AGNs) will be demonstrated. High radio frequency, i.e., mm-wave observations are promising probes of the X-ray emitting inner regions of the accretion disks in radio quiet AGNs. An argument for simultaneous observations in X-rays and in mm waves will be made, in order to promote these as one of the future science goals of X-ray and AGN astronomy in the next decade. Preliminary results from an exploratory campaign with several space and ground based telescopes will be presented.

  6. Measurement of the electron and ion temperatures by the x-ray imaging crystal spectrometer on joint Texas experimental tokamak

    NASA Astrophysics Data System (ADS)

    Yan, W.; Chen, Z. Y.; Jin, W.; Lee, S. G.; Shi, Y. J.; Huang, D. W.; Tong, R. H.; Wang, S. Y.; Wei, Y. N.; Ma, T. K.; Zhuang, G.

    2016-11-01

    An x-ray imaging crystal spectrometer has been developed on joint Texas experimental tokamak for the measurement of electron and ion temperatures from the Kα spectra of helium-like argon and its satellite lines. A two-dimensional multi-wire proportional counter has been applied to detect the spectra. The electron and ion temperatures have been obtained from the Voigt fitting with the spectra of helium-like argon ions. The profiles of electron and ion temperatures show the dependence on electron density in ohmic plasmas.

  7. X-Ray Activity in the Open Cluster IC 4665

    NASA Technical Reports Server (NTRS)

    Giamapapa, Mark S.; Prosser, Charles F.; Fleming, Thomas A.

    1997-01-01

    We present the results of a joint ROSAT High Resolution Imager (HRI) and optical investigation of the open cluster IC 4665. The ROSAT data contains detections for 28 stellar sources in the field, including 22 cluster members and candidate members spanning the color range -0.18 less than or equal to (B - V(sub o)) less than or equal to +1.63 (approx. B3 - M3). Upper limits are given for the remaining members (or candidate members) in the HRI field. Keck HIRES spectra have been obtained that yield radial and rotational velocity measures, respectively, for faint, low mass candidate members located within the field of the ROSAT HRI observation. In addition, photometry of possible optical counterparts to previously uncatalogued X-ray sources in the HRI field is presented. The trends in X-ray properties with (B - V) color in IC 4665 are found to be quite similar to that for other, more nearby young clusters such as the Pleiades and alpha Persei. In particular, a maximum in normalized X-ray luminosity of log (L(sub x)/L(sub bol)) approx. equal 3 is observed, beginning in the color range of (B - V)(sub o) = 0.7 - 0.8. This is similar to the corresponding color range among Pleiades members, in agreement with the earlier estimate, that the age of IC 4665 is similar to the age of the Pleiades. The correlation of rotation and X-ray emission levels is consistent with that in other young clusters. Among the high mass stars in IC 4665, five B stars are detected as X-ray sources. Of these, one is a spectroscopic binary while the remaining objects are apparently single staxs. The level of intrinsic X-ray emission observed in the rapidly rotating (v sini greater than 200 km/ s), single B stars is consistent with an origin due to shock heating of the ambient medium by radiatively driven, rotationally enhanced winds. On the basis of these observations and the results for other clusters, we argue that observed levels of X-ray emission in high mass stars of log (L(sub x)/L(sub bol

  8. Outflowing X-ray corona in Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Wang, Junxian; Liu, Teng; Yang, Huan; Zhu, Feifan; Zhou, Youyuan

    2015-08-01

    Hard X-ray emission in radio-quiet AGNs is believed to be produced via inverse Compton scattering by hot and compact corona near the super massive black hole. However the origin and physical properties of the coronae, including geometry, kinematics and dynamics, yet remain poorly known. Taking [OIV] 25.89um emission line as an isotropic indicator of AGN's intrinsic luminosity, we compare the intrinsic corona X-ray emission between Seyfert 1 and Compton-thin Seyfert 2 galaxies, which are viewed at different inclinations according to the unification scheme. We find that Seyfert 1 galaxies are brighter in "absorption-corrected" 2-10 keV emission by a factor of ~2.8, comparing with Compton-thin Seyfert 2 galaxies. The Seyfert 1 and Compton-thin Seyfert 2 galaxies follow a statistically identical correlation between the absorption-corrected 2-10 keV luminosity and the SWIFT BAT 14-195 keV luminosity, indicating that our absorption correction to the 2-10 keV flux is sufficient. The difference between the two populations thus can not be attributed to X-ray absorption, and instead implies an intrinsic anisotropy in the corona X-ray emission. This striking anisotropy of X-ray emission can be explained by a bipolar outflowing corona with a bulk velocity of ~0.3-0.5c. This would provide a natural link between the so-called coronae and weak jets in these systems. We also show that how this study would affect our understanding to the nature of mid-infrared emission in AGNs and the properties of dusty torus. Furthermore, such anisotropy implies that, contrary to previous understanding based on the assumption of isotropic corona emission, hard X-ray AGN surveys are biased against type 2 AGNs even after absorption-correction, and careful correction for this effect is required to measure the obscured fraction from X-ray surveys. Other interesting consequences of this discovery will also be discussed.

  9. Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range

    NASA Astrophysics Data System (ADS)

    Kavčič, M.; Budnar, M.; Mühleisen, A.; Gasser, F.; Žitnik, M.; Bučar, K.; Bohinc, R.

    2012-03-01

    A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

  10. Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range

    SciTech Connect

    Kavcic, M.; Budnar, M.; Muehleisen, A.; Gasser, F.; Zitnik, M.; Bucar, K.; Bohinc, R.

    2012-03-15

    A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

  11. Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range.

    PubMed

    Kavčič, M; Budnar, M; Mühleisen, A; Gasser, F; Žitnik, M; Bučar, K; Bohinc, R

    2012-03-01

    A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

  12. Ground calibrations of the X-ray detector system of the Solar Intensity X-ray Spectrometer (SIXS) on board BepiColombo

    NASA Astrophysics Data System (ADS)

    Huovelin, Juhani; Lehtolainen, Arto; Genzer, Maria; Korpela, Seppo; Esko, Eero; Andersson, Hans

    2014-05-01

    SIXS includes X-ray and particle detector systems for the BepiColombo Mercury Planetary Orbiter (MPO). Its task is to monitor the direct solar X-rays and energetic particles in a wide field of view in the energy range of 1-20 keV (X-rays), 0.1-3 MeV (electrons) and 1-30 MeV (protons). The main purpose of these measurements is to provide quantitative information on the high energy radiation incident on Mercury's surface which causes the X-ray glow of the planet measured by the MIXS instrument. The X-ray and particle measurements of SIXS are also useful for investigations of the solar corona and the magnetosphere of Mercury. The ground calibrations of the X-ray detectors of the SIXS flight model were carried out in the X-ray laboratory of the Helsinki University during May and June 2012. The aim of the ground calibrations was to characterize the performance of the SIXS instrument's three High-Purity Silicon PIN X-ray detectors and verify that they fulfil their scientific performance requirements. The calibrations included the determination of the beginning of life energy resolution at different operational temperatures, determination of the detector's sensitivity within the field of view as a function of the off-axis and roll angles, pile-up tests for determining the speed of the read out electronics, measurements of the low energy threshold of the energy scale, a cross-calibration with the SMART-1 XSM flight spare detector, and the determination of the temperature dependence of the energy scale. An X-ray tube and the detectors' internal Ti coated 55Fe calibration sources were used as primary X-ray sources. In addition, two external fluorescence sources were used as secondary X-ray sources in the determination of the energy resolutions and in the comparison calibration with the SMART-1 XSM. The calibration results show that the detectors fulfill all of the scientific performance requirements. The ground calibration data combined with the instrument house-keeping data

  13. The REgolith X-Ray Imaging Spectrometer (REXIS) for OSIRIS-REx: identifying regional elemental enrichment on asteroids

    NASA Astrophysics Data System (ADS)

    Allen, Branden; Grindlay, Jonathan; Hong, Jaesub; Binzel, Richard P.; Masterson, Rebecca; Inamdar, Niraj K.; Chodas, Mark; Smith, Matthew W.; Bautz, Marshall W.; Kissel, Steven E.; Villasenor, Joel; Oprescu, Miruna; Induni, Nicholas

    2013-09-01

    The OSIRIS-REx Mission was selected under the NASA New Frontiers program and is scheduled for launch in September of 2016 for a rendezvous with, and collection of a sample from the surface of asteroid Bennu in 2019. 101955 Bennu (previously 1999 RQ36) is an Apollo (near-Earth) asteroid originally discovered by the LINEAR project in 1999 which has since been classified as a potentially hazardous near-Earth object. The REgolith X-Ray Imaging Spectrometer (REXIS) was proposed jointly by MIT and Harvard and was subsequently accepted as a student led instrument for the determination of the elemental composition of the asteroid's surface as well as the surface distribution of select elements through solar induced X-ray fluorescence. REXIS consists of a detector plane that contains 4 X-ray CCDs integrated into a wide field coded aperture telescope with a focal length of 20 em for the detection of regions with enhanced abundance in key elements at 50 m scales. Elemental surface distributions of approximately 50-200 m scales can be detected using the instrument as a simple collimator. An overview of the observation strategy of the REXIS instrument and expected performance are presented here.

  14. Design of Time-Resolved Shifted Dual Transmission Grating Spectrometer for the X-Ray Spectrum Diagnostics

    NASA Astrophysics Data System (ADS)

    Wang, Baoqing; Yi, Tao; Wang, Chuanke; Zhu, Xiaoli; Li, Tingshuai; Li, Jin; Liu, Shenye; Jiang, Shaoen; Ding, Yongkun

    2016-07-01

    A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion. supported by National Natural Science Foundation of China (Nos. 11405158 and 11435011) and Development Foundation of China Academy of Engineering Physics (Nos. 2014B0102011 and 2014B0102012)

  15. Flight model performance test results of a helium dewar for the soft X-ray spectrometer onboard ASTRO-H

    NASA Astrophysics Data System (ADS)

    Yoshida, Seiji; Miyaoka, Mikio; Kanao, Ken'ichi; Tsunematsu, Shoji; Otsuka, Kiyomi; Hoshika, Shunji; Mitsuda, Kazuhisa; Yamasaki, Noriko; Takei, Yoh; Fujimoto, Ryuichi; Sato, Yoichi; DiPirro, Mike; Shirron, Peter

    2016-03-01

    ASTRO-H is a Japanese X-ray astronomy satellite, scheduled to be launched in fiscal year 2015. The mission includes a soft X-ray spectrometer instrument (SXS), which contains an X-ray micro calorimeter operating at 50 mK by using an adiabatic demagnetization refrigerator (ADR). The heat sink of the ADR is superfluid liquid helium below 1.3 K. The required lifetime of the superfluid helium is 3 years or more. In order to realize this lifetime, we have improved the thermal performance from the engineering model (EM) while maintaining the mechanical performance. Then, we have performed a thermal test of the flight model (FM). The results were that the heat load to the helium tank was reduced to below 0.8 mW in the FM from 1.2 mW in the EM. Therefore, the lifetime of the superfluid helium is more than 3 years with 30 L of liquid helium. In this paper, the thermal design and thermal test results are described.

  16. Photonuclear reaction based high-energy x-ray spectrometer to cover from 2 MeV to 20 MeV.

    PubMed

    Sakata, S; Arikawa, Y; Kojima, S; Ikenouchi, T; Nagai, T; Abe, Y; Inoue, H; Morace, A; Utsugi, M; Kato, R; Nishimura, H; Nakai, M; Shiraga, H; Fujioka, S; Azechi, H

    2014-11-01

    A photonuclear-reaction-based hard x-ray spectrometer is developed to measure the number and energy spectrum of fast electrons generated by interactions between plasma and intense laser light. In this spectrometer, x-rays are converted to neutrons through photonuclear reactions, and the neutrons are counted with a bubble detector that is insensitive to x-rays. The spectrometer consists of a bundle of hard x-ray detectors that respond to different photon-energy ranges. Proof-of-principle experiment was performed on a linear accelerator facility. A quasi-monoenergetic electron bunch (Ne = 1.0 × 10(-6) C, Ee = 16 ± 0.32 MeV) was injected into a 5-mm-thick lead plate. Bremsstrahlung x-rays, which emanate from the lead plate, were measured with the spectrometer. The measured spectral shape and intensity agree fairly well with those computed with a Monte Carlo simulation code. The result shows that high-energy x-rays can be measured absolutely with a photon-counting accuracy of 50%-70% in the energy range from 2 MeV to 20 MeV with a spectral resolution (Δhν/hν) of about 15%. Quantum efficiency of this spectrometer was designed to be 10(-7), 10(-4), 10(-5), respectively, for 2-10, 11-15, and 15-25 MeV of photon energy ranges.

  17. Method and apparatus for digitally based high speed x-ray spectrometer

    DOEpatents

    Warburton, William K.; Hubbard, Bradley

    1997-01-01

    A high speed, digitally based, signal processing system which accepts input data from a detector-preamplifier and produces a spectral analysis of the x-rays illuminating the detector. The system achieves high throughputs at low cost by dividing the required digital processing steps between a "hardwired" processor implemented in combinatorial digital logic, which detects the presence of the x-ray signals in the digitized data stream and extracts filtered estimates of their amplitudes, and a programmable digital signal processing computer, which refines the filtered amplitude estimates and bins them to produce the desired spectral analysis. One set of algorithms allow this hybrid system to match the resolution of analog systems while operating at much higher data rates. A second set of algorithms implemented in the processor allow the system to be self calibrating as well. The same processor also handles the interface to an external control computer.

  18. Method and apparatus for digitally based high speed x-ray spectrometer

    DOEpatents

    Warburton, W.K.; Hubbard, B.

    1997-11-04

    A high speed, digitally based, signal processing system which accepts input data from a detector-preamplifier and produces a spectral analysis of the x-rays illuminating the detector. The system achieves high throughputs at low cost by dividing the required digital processing steps between a ``hardwired`` processor implemented in combinatorial digital logic, which detects the presence of the x-ray signals in the digitized data stream and extracts filtered estimates of their amplitudes, and a programmable digital signal processing computer, which refines the filtered amplitude estimates and bins them to produce the desired spectral analysis. One set of algorithms allow this hybrid system to match the resolution of analog systems while operating at much higher data rates. A second set of algorithms implemented in the processor allow the system to be self calibrating as well. The same processor also handles the interface to an external control computer. 19 figs.

  19. The Einstein objective grating spectrometer survey of galactic binary X-ray sources

    NASA Technical Reports Server (NTRS)

    Vrtilek, S. D.; Mcclintock, J. E.; Seward, F. D.; Kahn, S. M.; Wargelin, B. J.

    1991-01-01

    The results of observations of 22 bright Galactic X-ray point sources are presented, and the most reliable measurements to date of X-ray column densities to these sources are derived. The results are consistent with the idea that some of the objects have a component of column density intrinsic to the source in addition to an interstellar component. The K-edge absorption due to oxygen is clearly detected in 10 of the sources and the Fe L and Ne K edges are detected in a few. The spectra probably reflect emission originating in a collisionally excited region combined with emission from a photoionized region excited directly by the central source.

  20. A lab-based ambient pressure x-ray photoelectron spectrometer with exchangeable analysis chambers

    SciTech Connect

    Newberg, John T. Arble, Chris; Goodwin, Chris; Khalifa, Yehia; Broderick, Alicia; Åhlund, John

    2015-08-15

    Ambient pressure X-ray photoelectron spectroscopy (APXPS) is a powerful spectroscopy tool that is inherently surface sensitive, elemental, and chemical specific, with the ability to probe sample surfaces under Torr level pressures. Herein, we describe the design of a new lab-based APXPS system with the ability to swap small volume analysis chambers. Ag 3d(5/2) analyses of a silver foil were carried out at room temperature to determine the optimal sample-to-aperture distance, x-ray photoelectron spectroscopy analysis spot size, relative peak intensities, and peak full width at half maximum of three different electrostatic lens modes: acceleration, transmission, and angular. Ag 3d(5/2) peak areas, differential pumping pressures, and pump performance were assessed under varying N{sub 2}(g) analysis chamber pressures up to 20 Torr. The commissioning of this instrument allows for the investigation of molecular level interfacial processes under ambient vapor conditions in energy and environmental research.

  1. X-ray spectrometer experiment aboard the ISEE-C /Heliocentric/ spacecraft

    NASA Technical Reports Server (NTRS)

    Anderson, K. A.; Kane, S. R.; Primbsch, J. H.; Weitzmann, R. H.; Evans, W. D.; Klebesadel, R. W.; Aiello, W. P.

    1978-01-01

    This experiment is designed to provide continuous coverage of solar flare X-ray bursts and transient cosmic gamma-ray bursts. A proportional counter and a scintillation detector together cover the energy range from 5 to 228 keV with good sensitivity, large dynamic range, and high temporal resolution. This experiment provides data storage capability and good absolute timing so that in conjunction with similar experiments on other spacecraft, accurate source locations can be obtained for cosmic gamma-ray bursts.

  2. Imaging soft x-ray spectrometers based on superconducting tunnel junctions

    NASA Astrophysics Data System (ADS)

    Verhoeve, P.; Martin, D. D. E.; Venn, R.

    2010-07-01

    X-ray detectors based on superconducting tunnel junctions (STJs) have demonstrated good energy resolution in the soft X-ray energy range 0.1-6 keV. In particular DROIDS (Distributed Read Out Imaging Devices), consisting of a superconducting absorber strip with superconducting tunnel junctions as read-out devices on either end, could combine this high resolving power with a large sensitive area and good soft X-ray detection efficiency. In this paper we present results on the spectroscopic performance of Al and Ta/Al DROIDs with different absorber materials (Ta, Re) and with variations in absorber configurations: our standard absorber integrated with the read-out structure is compared with absorbers deposited after definition of the read-out structure. The latter allows maximising the detection efficiency through thicker layers and different absorber materials. Also, absorbers which are electrically coupled to the readout structure are compared to insulated absorbers which couple to the readout structure by phonon exchange across a thin dielectric layer. New process routes have been designed for all new configurations. Whilst not all these structures have been fabricated successfully yet, our integrated absorber sofar exhibits the best performance, with 2.45 eV FWHM at 400 eV and 16.6 eV FWHM at 5.9 keV.

  3. Ground calibrations of the Solar Intensity X-ray Spectrometer (SIXS) on board BepiColombo

    NASA Astrophysics Data System (ADS)

    Lehtolainen, A.; Alha, L.; Huovelin, J.; Moissl, R.; Korpela, S.; Andersson, H.; Kuparinen, K.

    2014-01-01

    In this paper we present the methods, results, and analysis of the BepiColombo SIXS instruments' ground calibrations. The aim of these calibrations was to characterize the performance of the three SIXS X-ray detectors to enable reliable spectral analysis of the solar X-ray data. The ground calibrations for characterizing the performance of the three separate HPSi (High-Purity Silicon) PIN (Positive Intrinsic Negative) X-ray detectors included the following tasks. Determination of the energy resolution as a function of photon energy at different operational temperatures, determination of the detector sensitivity within the FoV (Field of View) as a function of the off-axis and roll angles, pile-up tests for determining the speed of the read out electronics, measurements of the low energy threshold of the energy scale, i.e. the minimum measurable photon energy corresponding to the adjustable software parameter, a comparison calibration of the fluorescence line fluxes with the SMART-1 XSM FS (Flight Spare) detector, and determination of the shifting of the energy scale as a function of the ambient temperature. We also describe the method and results of determining the geometrical area of the detector apertures based on the image analysis of very high resolution photographs obtained with by the Scanning Electron Microscope (SEM).

  4. Coronal X-Ray Flares on Active Stars

    NASA Astrophysics Data System (ADS)

    Nordon, Raanan

    2008-09-01

    Stellar coronae are the hot (kT>0.1 keV) tenuous regions in the outer atmospheres of cool-stars. Stellar coronae have been researched for many years, and yet they are poorly understood. In particular, the deviation of coronal chemical composition from photospheric elemental abundances is a long standing mystery. In the solar case, this was labeled the first ionization potential (FIP) effect. While some stellar coronae show a solar-like FIP effect, others show no FIP effect, or an inverse effect, although difficulties in measuring stellar photospheric abundances cast some doubt on these results. A correlation between coronal activity and abundance patterns led to a suggestion that flares affect coronal abundances. However, different variations were observed during flares, with no clear pattern emerging. We investigate a full sample of X-ray flares on stellar coronae from the archives of XMM-Newton and Chandra space observatories. We develop a method for reconstructing emission measure distribution, EMD(T), and abundances that is optimized to reduce systematic uncertainties. We measure variations of coronal abundances during flares, relative to quiescence abundances. This measurement is independent of the photospheric abundances and their related uncertainties. A theoretical analysis of the EMD(T) degeneracy problem is also presented. We find excess emission during flares originates predominantly from temperatures of kT>2 keV, while the low-T emission is very close to quiescence. This result cannot be reconciled with pure radiative-cooling or simple conductive-cooling. Evaporation from low dense regions into higher, thinner corona may aid in explaining this observed behavior. We define a relative measure for the FIP bias and compare the FIP bias of flare vs. quiescence with that of quiescence vs. photospheric (solar). We discovered a general trend where the relative FIP bias during flares is opposite to the quiescence FIP bias, meaning that the flares tend to

  5. Demonstrating Enabling Technologies for the High-Resolution Imaging Spectrometer of the Next NASA X-ray Astronomy Mission

    NASA Astrophysics Data System (ADS)

    Kilbourne, Caroline; Adams, J. S.; Bandler, S.; Chervenak, J.; Chiao, M.; Doriese, R.; Eckart, M.; Finkbeiner, F.; Fowler, J. W.; Hilton, G.; Irwin, K.; Kelley, R. L.; Moseley, S. J.; Porter, F. S.; Reintsema, C.; Sadleir, J.; Smith, S. J.; Swetz, D.; Ullom, J.

    2014-01-01

    NASA/GSFC and NIST-Boulder are collaborating on a program to advance superconducting transition-edge sensor (TES) microcalorimeter technology toward Technology Readiness Level (TRL) 6. The technology development for a TES imaging X-ray microcalorimeter spectrometer (TES microcalorimeter arrays and time-division multiplexed SQUID readout) is now at TRL 4, as evaluated by both NASA and the European Space Agency (ESA) during mission formulation for the International X-ray Observatory (IXO). We will present the status of the development program. The primary goal of the current project is to advance the core X-ray Microcalorimeter Spectrometer (XMS) detector-system technologies to a demonstration of TRL 5 in 2014. Additional objectives are to develop and demonstrate two important related technologies to at least TRL 4: position-sensitive TES devices and code-division multiplexing (CDM). These technologies have the potential to expand significantly the range of possible instrument optimizations; together they allow an expanded focal plane and higher per-pixel count rates without greatly increasing mission resources. The project also includes development of a design concept and critical technologies needed for the thermal, electrical, and mechanical integration of the detector and readout components into the focal-plane assembly. A verified design concept for the packaging of the focal-plane components will be needed for the detector system eventually to advance to TRL 6. Thus, the current project is a targeted development and demonstration program designed to make significant progress in advancing the XMS detector system toward TRL 6, establishing its readiness for a range of possible mission implementations.

  6. Development status of the mechanical cryocoolers for the Soft X-ray Spectrometer on board Astro-H

    NASA Astrophysics Data System (ADS)

    Sato, Yoichi; Sawada, Kenichiro; Shinozaki, Keisuke; Sugita, Hiroyuki; Nishibori, Toshiyuki; Sato, Ryota; Mitsuda, Kazuhisa; Yamasaki, Noriko Y.; Takei, Yoh; Goto, Ken; Nakagawa, Takao; Fujimoto, Ryuichi; Kikuchi, Kenichi; Murakami, Masahide; Tsunematsu, Shoji; Ootsuka, Kiyomi; Kanao, Kenichi; Narasaki, Katsuhiro

    2014-11-01

    Astro-H is the Japanese X-ray astronomy satellite to be launched in 2015. The Soft X-ray Spectrometer (SXS) on board Astro-H is a high energy resolution spectrometer utilizing an X-ray micro-calorimeter array, which is operated at 50 mK by the ADR with the 30 liter superfluid liquid helium. The mechanical cryocoolers, 4 K-class Joule Thomson (JT) cooler and 20 K-class double-staged Stirling (2ST) cooler, are key components of the SXS cooling system to extend the lifetime of LHe cryogen beyond 3 years as required. Higher reliability was therefore investigated with higher cooling capability based on the heritage of existing cryocoolers. As the task of assessing further reliability dealt with the pipe-choking phenomena by contaminant solidification of the on-orbit SMILES JT cryocooler, outgassing from materials and component parts used in the cryocoolers was measured quantitatively to verify the suppression of carbon dioxide gas by their storage process and predict the total accumulated carbon dioxide for long-term operation. A continuous running test to verify lifetime using the engineering model (EM) of the 4 K-JT cooler is underway, having operated for a total of 720 days as of June 2013 and showing no remarkable change in cooling performance. During the current development phase, prototype models (PM) of the cryocoolers were installed to the test SXS dewar (EM) to verify the overall cooling performance from room temperature to 50 mK. During the EM dewar test, the requirement to reduce the transmitted vibration from the 2ST cooler compressor was recognized as mitigating the thermal instability of the SXS microcalorimeter at 50 mK.

  7. A COMPARISON OF X-RAY AND MID-INFRARED SELECTION OF OBSCURED ACTIVE GALACTIC NUCLEI

    SciTech Connect

    Eckart, Megan E.; Harrison, Fiona A.; McGreer, Ian D.; Helfand, David J.; Stern, Daniel

    2010-01-01

    We compare the relative merits of active galactic nuclei (AGNs) selection at X-ray and mid-infrared wavelengths using data from moderately deep fields observed by both Chandra and Spitzer. The X-ray-selected AGN sample and associated photometric and spectroscopic optical follow-up are drawn from a subset of fields studied as part of the Serendipitous Extragalactic X-ray Source Identification (SEXSI) program. Mid-infrared data in these fields are derived from targeted and archival Spitzer imaging, and mid-infrared AGN selection is accomplished primarily through application of the Infrared Array Camera (IRAC) color-color AGN 'wedge' selection technique. Nearly all X-ray sources in these fields which exhibit clear spectroscopic signatures of AGN activity have mid-infrared colors consistent with IRAC AGN selection. These are predominantly the most luminous X-ray sources. X-ray sources that lack high-ionization and/or broad lines in their optical spectra are far less likely to be selected as AGNs by mid-infrared color selection techniques. The fraction of X-ray sources identified as AGNs in the mid-infrared increases monotonically as the X-ray luminosity increases. Conversely, only 22% of mid-infrared-selected AGNs are detected at X-ray energies in the moderately deep ((t{sub exp}) approx 100 ks) SEXSI Chandra data. We hypothesize that IRAC sources with AGN colors that lack X-ray detections are predominantly high-luminosity AGNs that are obscured and/or lie at high redshift. A stacking analysis of X-ray-undetected sources shows that objects in the mid-infrared AGN selection wedge have average X-ray fluxes in the 2-8 keV band 3 times higher than sources that fall outside the wedge. Their X-ray spectra are also harder. The hardness ratio of the wedge-selected stack is consistent with moderate intrinsic obscuration, but is not suggestive of a highly obscured, Compton-thick source population. It is evident from this comparative study that in order to create a complete

  8. Combined Backscatter Moessbauer Spectrometer and X Ray Fluorescence analyzer (BaMS/XRF) for planetary surface materials

    NASA Technical Reports Server (NTRS)

    Agresti, D. G.; Shelfer, T. D.; Pimperl, M. M.; Wills, E. L.; Morris, R. V.

    1991-01-01

    A backscatter Moessbauer spectrometer (BaMS) with included x ray fluorescence (XRF) capability for the Mars Environment Survey (MESUR) Mission, which has been proposed by NASA for 1998, is being developed. The instrument will also be suitable for other planetary missions such as those to the Moon, asteroids, and other solid solar-system objects. The BaMS would be unique for MESUR in providing information about iron mineralogy in rocks, clays, and other surface materials, including relative proportions of iron-bearing minerals. It requires no sample preparation and can identify all the normal oxidation states of iron (3+, 2+, 0). Thus, BaMS is diagnostic for weathering and other soil-forming processes. Backscatter design allows the addition of XRF elemental analysis with little or no modification. The BaMS/XRF instrument complements the thermal analyzer with evolved gas analyzer (TA-EGA) and the alpha-proton x-ray spectrometer (APXS) proposed (along with BaMS) for geochemical analysis on MESUR.

  9. Ultrahigh energy resolution focusing monochromator for inelastic x-ray scattering spectrometer.

    PubMed

    Suvorov, Alexey; Cunsolo, Alessandro; Chubar, Oleg; Cai, Yong Q

    2015-11-30

    A further development of a focusing monochromator concept for X-ray energy resolution of 0.1 meV and below is presented. Theoretical analysis of several optical layouts based on this concept was supported by numerical simulations performed in the "Synchrotron Radiation Workshop" software package using the physical-optics approach and careful modeling of partially-coherent synchrotron (undulator) radiation. Along with the energy resolution, the spectral shape of the energy resolution function was investigated. It was shown that under certain conditions the decay of the resolution function tails can be faster than that of the Gaussian function.

  10. LABORATORY EVALUATION OF SIX NEW/MODIFIED PORTABLE X-RAY FLUORESCENCE SPECTROMETERS FOR THE MEASUREMENT OF LEAD IN CHARACTERIZED PAINT FILMS AND RESEARCH MATERIAL BOARDS (TECHNICAL REPORT)

    EPA Science Inventory

    A laboratory study was performed in 1994-1995 to identify and estimate the influence of key characteristics for evaluating the performance of portable X-ray fluorescence (XRF) spectrometers. Six new/modified spectrometers, including HNU SEFA-Pb, Metorex X-MET, Niton X-L, Radiat...

  11. LABORATORY EVALUATION OF SIX NEW/MODIFIED PORTABLE X-RAY FLUORESCENCE SPECTROMETERS FOR THE MEASUREMENT OF LEAD IN CHARACTERIZED PAINT FILMS AND RESEARCH MATERIAL BOARDS (APPENDICES)

    EPA Science Inventory

    A laboratory study was performed in 1994-1995 to identify and estimate the influence of key characteristics for evaluating the performance of portable X-ray fluorescence (XRF) spectrometers. Six new/modified spectrometers, including HNU SEFA-Pb, Metorex X-MET, Niton X-L, Radiat...

  12. Determination of selenium in biological samples with an energy-dispersive X-ray fluorescence spectrometer.

    PubMed

    Li, Xiaoli; Yu, Zhaoshui

    2016-05-01

    Selenium is both a nutrient and a toxin. Selenium-especially organic selenium-is a core component of human nutrition. Thus, it is very important to measure selenium in biological samples. The limited sensitivity of conventional XRF hampers its widespread use in biological samples. Here, we describe the use of high-energy (100kV, 600W) linearly polarized beam energy-dispersive X-Ray fluorescence spectroscopy (EDXRF) in tandem with a three-dimensional optics design to determine 0.1-5.1μgg(-1) levels of selenium in biological samples. The effects of various experimental parameters such as applied voltage, acquisition time, secondary target and various filters were thoroughly investigated. The detection limit of selenium in biological samples via high-energy (100kV, 600W) linearly polarized beam energy-dispersive X-ray fluorescence spectroscopy was decreased by one order of magnitude versus conventional XRF (Paltridge et al., 2012) and found to be 0.1μg/g. To the best of our knowledge, this is the first report to describe EDXRF measurements of Se in biological samples with important implications for the nutrition and analytical chemistry communities. PMID:26922394

  13. Normal incidence X-ray telescope power spectra of X-ray emission from solar active regions. I - Observations. II - Theory

    NASA Technical Reports Server (NTRS)

    Gomez, Daniel O.; Martens, Petrus C. H.; Golub, Leon

    1993-01-01

    Fourier analysis is applied to very high resolution image of coronal active regions obtained by the Normal Incidence X-Ray Telescope is used to find a broad isotropic power-law spectrum of the spatial distribution of soft X-ray intensities. Magnetic structures of all sizes are present down to the resolution limit of the instrument. Power spectra for the X-ray intensities of a sample of topologically different active regions are found which fall off with increasing wavenumber as 1/k-cubed. A model is presented that relates the basic features of coronal magnetic fluctuations to the subphotospheric hydrodynamic turbulence that generates them. The model is used to find a theoretical power spectrum for the X-ray intensity which falls off with increasing wavenumber as 1/k-cubed. The implications of a turbulent regime in active regions are discussed.

  14. A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas.

    PubMed

    Chen, Hui; Bitter, M; Hill, K W; Kerr, S; Magee, E; Nagel, S R; Park, J; Schneider, M B; Stone, G; Williams, G J; Beiersdorfer, P

    2014-11-01

    Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10(19)-10(20) W/cm(2). He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

  15. A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas

    SciTech Connect

    Chen, Hui E-mail: bitter@pppl.gov; Magee, E.; Nagel, S. R.; Park, J.; Schneider, M. B.; Stone, G.; Williams, G. J.; Beiersdorfer, P.; Bitter, M. E-mail: bitter@pppl.gov; Hill, K. W.; Kerr, S.

    2014-11-15

    Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10{sup 19}–10{sup 20} W/cm{sup 2}. He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

  16. The Fourier Imaging X-ray Spectrometer (FIXS) for the Argentinian, Scout-launched satelite de Aplicaciones Cienficas-1 (SAC-1)

    NASA Technical Reports Server (NTRS)

    Dennis, Brian R.; Crannell, Carol JO; Desai, Upendra D.; Orwig, Larry E.; Kiplinger, Alan L.; Schwartz, Richard A.; Hurford, Gordon J.; Emslie, A. Gordon; Machado, Marcos; Wood, Kent

    1988-01-01

    The Fourier Imaging X-ray Spectrometer (FIXS) is one of four instruments on SAC-1, the Argentinian satellite being proposed for launch by NASA on a Scout rocket in 1992/3. The FIXS is designed to provide solar flare images at X-ray energies between 5 and 35 keV. Observations will be made on arcsecond size scales and subsecond time scales of the processes that modify the electron spectrum and the thermal distribution in flaring magnetic structures.

  17. Analysis of X-ray and EUV spectra of solar active regions

    NASA Technical Reports Server (NTRS)

    Strong, K. T.; Acton, L. W.

    1979-01-01

    Data acquired by two flights of an array of six Bragg crystal spectrometers on an Aerobee rocket to obtain high spatial and spectral resolution observations of various coronal features at soft X-ray wavelengths (9-23A) were analyzed. The various aspects of the analysis of the X-ray data are described. These observations were coordinated with observations from the experiments on the Apollo Telescope Mount and the various data sets were related to one another. The Appendices contain the published results, abstracts of papers, computer code descriptions and preprints of papers, all produced as a result of this research project.

  18. Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

    NASA Astrophysics Data System (ADS)

    Gamboa, E. J.; Bachmann, B.; Kraus, D.; MacDonald, M. J.; Bucher, M.; Carron, S.; Coffee, R. N.; Drake, R. P.; Emig, J.; Ferguson, K. R.; Fletcher, L. B.; Glenzer, S. H.; Gorkhover, T.; Hau-Riege, S. P.; Krzywinski, J.; Levitan, A. L.; Meiwes-Broer, K.-H.; Osipov, T.; Pardini, T.; Peltz, C.; Skruszewicz, S.; Bostedt, C.; Fennel, T.; Döppner, T.

    2016-08-01

    With the recent development of high-repetition rate x-ray free electron lasers (FEL), it is now possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. Here we describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. The signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.

  19. Calibration of the lunar orbital x-ray fluorescence imaging spectrometer (LOXIA) of Chang'E-1 satellite at INAF-OAPA

    NASA Astrophysics Data System (ADS)

    Barbera, Marco; Candia, Roberto; Collura, Alfonso; Di Cicca, Gaspare; Varisco, Salvatore; Zhang, Chengmo; Wang, Huan Yu; Yang, JiaWei; Peng, Wenxi; Cui, Xingzhu; Cao, XueLei; Liang, XiaoHua

    2007-09-01

    The Lunar Orbital X-ray Fluorescence Imaging Spectrometer (LOXIA) designed and constructed at the Institute of High Energy Physics of the Chinese Academy of Sciences to perform chemical composition analysis of the Moon surface will operate on-board the Chang'E-1 mission, the first Chinese lunar spacecraft to be launched in 2007. We report the main results of the calibration measurements that we have performed using the X-ray beamline of the XACT facility of INAFOsservatorio Astronomico di Palermo G.S. Vaiana to determine the quantum efficiency of the XRS detector in the soft X-rays as a function of photon energy and angle of incidence.

  20. Hyper-filter-fluorescer spectrometer for x-rays above 120 keV

    DOEpatents

    Wang, Ching L.

    1983-01-01

    An apparatus utilizing filter-fluorescer combinations is provided to measure short bursts of high fluence x-rays above 120 keV energy, where there are no practical absorption edges available for conventional filter-fluorescer techniques. The absorption edge of the prefilter is chosen to be less than that of the fluorescer, i.e., E.sub.PRF E.sub.F. In this way, the response function is virtually zero between E.sub.PRF and E.sub.F and well defined and enhanced in an energy band of less than 1000 keV above the 120 keV energy.

  1. Calcium and Phosphorus Detection Using Benchtop Versus Handheld X-ray Fluorescence Spectrometers.

    PubMed

    Kuzel, Aaron R; Christensen, Angi M; Marvin, Susan M

    2016-01-01

    Elemental analysis of calcium (Ca) and phosphorus (P) has been shown to be useful in differentiating skeletal and nonskeletal material. X-ray fluorescence spectrometry (XRF) is an attractive, nondestructive technique for forensic anthropologists, and the development of portable XRF instrumentation is promising for field applications. This study examines the performance of handheld XRF instrumentation operated in air compared to a traditional benchtop XRF device that has the ability to control the analysis atmosphere. Both instruments can be used to effectively distinguish skeletal from nonskeletal remains. However, as the measurement atmosphere affects detection levels for calcium and phosphorus, Ca/P ratios obtained from the instruments and analysis conditions were found to differ significantly, with analyses conducted in air showing significantly lower phosphorus detection. Consequently, comparison of Ca/P ratios to conclude skeletal versus nonskeletal origin must be based on data collected under similar analysis conditions.

  2. He flow rate measurements on the engineering model for the Astro-H Soft X-ray Spectrometer dewar

    NASA Astrophysics Data System (ADS)

    Mitsuishi, I.; Ezoe, Y.; Ishikawa, K.; Ohashi, T.; Fujimoto, R.; Mitsuda, K.; Tsunematsu, S.; Yoshida, S.; Kanao, K.; Murakami, M.; DiPirro, M.; Shirron, P.

    2014-11-01

    The sixth X-ray Japanese astronomy satellite, namely Astro-H, will be launched in 2015. The Soft X-ray Spectrometer onboard the Astro-H is a 6 × 6 X-ray microcalorimeter array and provides us with both a high energy resolution of <7 eV at 0.5-10 keV and a 3‧ × 3‧ modest imaging capability for the first time. To cool the detector down to the operation temperature of 50 mK, five cryocoolers, a 30-L superfluid helium cryostat, and a 3-stage adiabatic demagnetization refrigerator are utilized. A very small heat load up to ∼0.9 mW on the helium tank is allowable to realize the helium lifetime of >3 years, which consequently requires that the vapor flow rate out of the helium tank should be very small <42 μg/s. We adopted a porous plug phase separator in combination with a film flow suppression system composed of an orifice, a heat exchanger and knife edge devices to retain the liquid helium under zero gravity and safely vent the small amount of the helium vapor. We measured helium mass flow rates from the helium tank equipped in the engineering model dewar. We tilted the dewar at an angle of 75° so that one side of the porous plug located at the top of the helium tank attaches the liquid helium and the porous plug separates the liquid and vapor helium by thermomechanical effect. Helium mass flow rates were measured at helium tank temperatures of 1.3, 1.5 and 1.9 K. We confirmed that resultant mass flow rates are in good agreement within the systematic error or low compared to component test results and achieve all the requirements. The film flow suppression also worked normally. Therefore, we concluded that the SXS helium vent system satisfactorily performs integrated into the dewar.

  3. Engineering design of the Regolith X-ray Imaging Spectrometer (REXIS) instrument: an OSIRIS-REx student collaboration

    NASA Astrophysics Data System (ADS)

    Jones, Michael; Chodas, Mark; Smith, Matthew J.; Masterson, Rebecca A.

    2014-07-01

    OSIRIS-REx is a NASA New Frontiers mission scheduled for launch in 2016 that will travel to the asteroid Bennu and return a pristine sample of the asteroid to Earth. The REgolith X-ray Imaging Spectrometer (REXIS) is a student collaboration instrument on-board the OSIRIS-REx spacecraft. REXIS is a NASA risk Class D instrument, and its design and development is largely student led. The engineering team consists of MIT graduate and undergraduate students and staff at the MIT Space Systems Laboratory. The primary goal of REXIS is the education of science and engineering students through participation in the development of light hardware. In light, REXIS will contribute to the mission by providing an elemental abundance map of the asteroid and by characterizing Bennu among the known meteorite groups. REXIS is sensitive to X-rays between 0.5 and 7 keV, and uses coded aperture imaging to map the distribution of iron with 50 m spatial resolution. This paper describes the science goals, concept of operations, and overall engineering design of the REXIS instrument. Each subsystem of the instrument is addressed with a high-level description of the design. Critical design elements such as the Thermal Isolation Layer (TIL), radiation cover, coded-aperture mask, and Detector Assembly Mount (DAM) are discussed in further detail.

  4. High Resolution X-Ray Spectroscopy of zeta Puppis with the XMM-Newton Reflection Grating Spectrometer

    NASA Technical Reports Server (NTRS)

    Kahn, S. M.; Leutenegger, M. A.; Cottam, J.; Rauw, G.; Vreux, J.-M.; denBoggende, A. J. F.; Mewe, R.; Guedel, M.

    2000-01-01

    We present the first high resolution X-ray spectrum of the bright O4Ief supergiant star Puppis, obtained with the Reflection Grating Spectrometer on- board XMM-Newton. The spectrum exhibits bright emission lines of hydrogen-like and helium-like ions of nitrogen, oxygen, neon, magnesium, and silicon, as well as neon-like ions of iron. The lines are all significantly resolved, with characteristic velocity widths of order 1000 - 1500 km/ s. The nitrogen lines are especially strong, and indicate that the shocked gas in the wind is mixed with CNO-burned material, as has been previously inferred for the atmosphere of this star from ultraviolet spectra. We find that the forbidden to intercombination line ratios within the helium-like triplets are anomalously low for N VI, O VII, and Ne IX. While this is sometimes indicative of high electron density, we show that in this case, it is instead caused by the intense ultraviolet radiation field of the star. We use this interpretation to derive constraints on the location of the X-ray emitting shocks within the wind that agree remarkably well with current theoretical models for this system.

  5. A global Mars dust composition refined by the Alpha-Particle X-ray Spectrometer in Gale Crater

    NASA Astrophysics Data System (ADS)

    Berger, Jeff A.; Schmidt, Mariek E.; Gellert, Ralf; Campbell, John L.; King, Penelope L.; Flemming, Roberta L.; Ming, Douglas W.; Clark, Benton C.; Pradler, Irina; VanBommel, Scott J. V.; Minitti, Michelle E.; Fairén, Alberto G.; Boyd, Nicholas I.; Thompson, Lucy M.; Perrett, Glynis M.; Elliott, Beverley E.; Desouza, Elstan

    2016-01-01

    Modern Martian dust is similar in composition to the global soil unit and bulk basaltic Mars crust, but it is enriched in S and Cl. The Alpha Particle X-ray Spectrometer (APXS) on the Mars Science Laboratory Curiosity rover analyzed air fall dust on the science observation tray (o-tray) in Gale Crater to determine dust oxide compositions. The o-tray dust has the highest concentrations of SO3 and Cl measured in Mars dust (SO3 8.3%; Cl 1.1 wt %). The molar S/Cl in the dust (3.35 ± 0.34) is consistent with previous studies of Martian dust and soils (S/Cl = 3.7 ± 0.7). Fe is also elevated ~25% over average Mars soils and the bulk crust. These enrichments link air fall dust with the S-, Cl-, and Fe-rich X-ray amorphous component of Gale Crater soil. Dust and soil have the same S/Cl, constraining the surface concentrations of S and Cl on a global scale.

  6. The corona of HD 189733 and its X-ray activity

    SciTech Connect

    Pillitteri, I.; Wolk, S. J.; Günther, H. M.; Cohen, O.; Kashyap, V.; Drake, J. J.; Lopez-Santiago, J.; Sciortino, S.

    2014-04-20

    Testing whether close-in massive exoplanets (hot Jupiters) can enhance the stellar activity in their host primary is crucial for the models of stellar and planetary evolution. Among systems with hot Jupiters, HD 189733 is one of the best studied because of its proximity, strong activity, and the presence of a transiting planet, which allows transmission spectroscopy and a measure of the planetary radius and its density. Here we report on the X-ray activity of the primary star, HD 189733 A, using a new XMM-Newton observation and a comparison with the previous X-ray observations. The spectrum in the quiescent intervals is described by two temperatures at 0.2 keV and 0.7 keV, while during the flares a third component at 0.9 keV is detected. With the analysis of the summed Reflection Grating Spectrometer spectra, we obtain estimates of the electron density in the range n{sub e} = (1.6-13) × 10{sup 10} cm{sup –3}, and thus the corona of HD 189733 A appears denser than the solar one. For the third time, we observe a large flare that occurred just after the eclipse of the planet. Together with the flares observed in 2009 and 2011, the events are restricted to a small planetary phase range of φ = 0.55-0.65. Although we do not find conclusive evidence of a significant excess of flares after the secondary transits, we suggest that the planet might trigger such flares when it passes close to the locally high magnetic field of the underlying star at particular combinations of stellar rotational phases and orbital planetary phases. For the most recent flares, a wavelet analysis of the light curve suggests a loop of length of four stellar radii at the location of the bright flare, and a local magnetic field of the order of 40-100 G, in agreement with the global field measured in other studies. The loop size suggests an interaction of magnetic nature between planet and star, separated by only ∼8R {sub *}. The X-ray variability of HD 189733 A is larger than the variability

  7. Spectra and Luminosities of X-Ray Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Morgan, Windsor Anthony, Jr.

    1995-01-01

    I present results of the analysis of 112 X-ray -selected and fully optically-identified quasars in four sky fields in the southern hemisphere, detected by the Rosat Position Sensitive Proportional Counters. These fields were originally studied (Boyle et al. 1990) for the ultraviolet-excess properties of objects in the fields. This is one of the largest sets of fully-identified Rosat-observed quasars. The quasars were optically identified during observing runs with the AUTOFIB multi-fiber spectrograph on the Anglo-Australian Telescope in Australia. I determine the quasars' power-law spectral index alphaE with three different methods: spectral "stacking", hardness ratios, and direct fitting, and discuss the differences between each of these methods. Both spectral stacking and the hardness ratio methods are used because several of the quasars were too dim to reliably calculate spectral indices individually. The spectral stacking method, which involves co-adding quasar spectra energy bins (after first binning the quasars themselves in redshift bins) shows that a definite change in quasar spectral index with redshift, which I have attributed to thermal bremsstrahlung emission (Morgan et al. 1992). The hardness ratio method, taken from a suggestion by Zamorani et al. (1988), uses the hardness ratios, using energy bins of 0.15-0.8 keV and 0.8-2.0 keV, and the known galactic column density N_{H } to determine the quasar power-law spectral index. I find that the hardness-ratio method yields spectral indices which do not change appreciably with redshift. I derive monochromatic X-ray and optical luminosities L_{rm x} and L opt, by using the spectral indices I found and the optical observations of the quasars. I discuss the relationship between L_{x } and Lopt, examine the optical-X-ray spectral slope alpha ox and the related L x/L_{opt } ratio and their relationship to the redshift. I finally present a model which could explain the observations.

  8. SAXES, a high resolution spectrometer for resonant x-ray emission in the 400-1600 eV energy range

    SciTech Connect

    Ghiringhelli, G.; Piazzalunga, A.; Dallera, C.; Trezzi, G.; Braicovich, L.; Schmitt, T.; Strocov, V. N.; Betemps, R.; Patthey, L.; Wang, X.; Grioni, M.

    2006-11-15

    We present a 5 m long spectrometer for soft x rays to be used at a synchrotron radiation beamline for resonant x-ray emission spectroscopy and resonant inelastic x-ray scattering in the 400-1600 eV energy range. It is based on a variable line spacing spherical grating (average groove density of 3200 mm{sup -1}, R=58.55 m) and a charge coupled device two dimensional detector. With an x-ray spot on the sample of 10 {mu}m, the targeted resolving power is higher than 10 000 at all energies below 1100 eV and better than 7000 at 1500 eV. The off-line tests made with Al and Mg K{alpha}{sub 1,2} fluorescence emissions indicate that the spectrometer can actually work at 12 000 and 17 000 resolving power at the L{sub 3} edges of Cu (930 eV) and of Ti (470 eV), respectively. SAXES (superadvanced x-ray emission spectrometer) is mounted on a rotating platform allowing to vary the scattering angle from 25 degree sign to 130 degree sign . The spectrometer will be operational at the ADRESS (advanced resonant spectroscopies) beamline of the Swiss Light Source from 2007.

  9. Measurements of ion and electron temperature profiles on NSTX with an X-ray imaging crystal spectrometer

    NASA Astrophysics Data System (ADS)

    Bitter, M.; Beiersdorfer, P.; Gu, M. F.

    2005-10-01

    The prototype of a new X-ray imaging crystal spectrometer has been installed on NSTX to measure profiles of the ion and electron temperatures from spatially resolved dielectronic satellite spectra of ArXVII in the wavelength range from 3.9 to 4.0 A [1]. The spectrometer consists of a spherically bent 110-quartz crystal, with a radius of curvature of 389 cm and a diameter of 10 cm, and a 10 cm x 30 cm, two-dimensional, position-sensitive, multi-wire proportional counter. It projects an image of a large area of the plasma with an extension of +/- 40 cm below and above the horizontal mid-plane of NSTX onto the detector with a demagnification of 2.5. The resolution in the plasma is solely determined by the Bragg angle, the height of the crystal and its distance from the plasma; and it is about 3 cm, if the crystal is fully opened. The concept of this new spectrometer is also of interest for ion temperature measurements on ITER [2]. The paper will present results from profile measurements of the ion and electron temperature from NSTX discharges with pure ohmic heating as well as RF and neutral-beam heating. [1] M. Bitter et al., Rev. Sci. Instrum.75, 3660 (2004); [2] R. Barnsley et al., Rev. Sci. Instrum.75, 3743 (2004).

  10. Data Processing for the Near Earth Asteroid Rendezvous (NEAR), X-ray and Gamma-ray Spectrometer (XGRS) Ground System

    NASA Technical Reports Server (NTRS)

    McClanahan, Timothy P.; Mikheeva, I.; Trombka, J. I.; Floyd, S. R.; Boynton, W. V.; Bailey, H.; Bhangoo, J.; Starr, R.; Clark, P. E.; Evans, L. G.

    1999-01-01

    An X-ray and Gamma-ray spectrometer (XGRS) is onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft to determine the elemental composition of the surface of the asteroid 433Eros. The Eros asteroid is highly non-spherical in physical shape and the development of data management and analysis methodologies are in several areas a divergence from traditional remotely sensed geographical information systems techniques. Field of view and asteroid surface geometry must be derived virtually and then combined with real measurements of solar, spectral and instrument calibration information to derive meaningful scientific results. Spatial resolution of planned geochemical maps will be improved from the initial conditions of low statistical significance per integration by repeated surface flyovers and regional spectral accumulation. This paper describes the results of a collaborative effort of design and development of the NEAR XGRS instrument ground system undertaken by participants at the Goddard Space Flight Center, University of Arizona, Cornell University, Applied Physics Laboratory, and Max Plank institute.

  11. Data Processing for the Near Earth Asteroid Rendezvous (NEAR), X-Ray and Gamma-Ray Spectrometer (XRS) Ground System

    NASA Technical Reports Server (NTRS)

    McClanahan, Timothy P.; Mikheeva, I.; Trombka, J. I.; Floyd, S. R.; Boynton, W. V.; Bailey, H.; Bhangoo, J.; Starr, R.; Clark, P. E.; Evans, L. G.

    1999-01-01

    An X-ray and Gamma-ray spectrometer (XGRS) is onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft to determine the elemental composition of the surface of the asteroid 433Eros. The Eros asteroid is highly non-spherical in physical shape and the development of data management and analysis methodologies are in several areas a divergence from traditional remotely sensed geographical information systems techniques. Field of view and asteroid surface geometry must be derived virtually and then combined with real measurements of solar, spectral and instrument calibration information to derive meaningful scientific results. Spatial resolution of planned geochemical maps will be improved from the initial conditions of low statistical significance per integration by repeated surface flyovers and regional spectral accumulation. This paper describes the results of a collaborative effort of design and development of the NEAR XGRS instrument ground system undertaken by participants at the Goddard Space Flight Center, University of Arizona, Cornell University, Applied Physics Laboratory, and Max Plank institute.

  12. Development of a Silicon Drift Detector Array: An X-Ray Fluorescence Spectrometer for Remote Surface Mapping

    NASA Technical Reports Server (NTRS)

    Gaskin, Jessica A.; Carini, Gabriella A.; Wei, Chen; Elsner, Ronald F.; Kramer, Georgiana; De Geronimo, Gianluigi; Keister, Jeffrey W.; Zheng, Li; Ramsey, Brian D.; Rehak, Pavel; Siddons, D. Peter

    2009-01-01

    Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

  13. Very high resolution UV and X-ray spectroscopy and imagery of solar active regions

    NASA Technical Reports Server (NTRS)

    Bruner, M.; Brown, W. A.; Haisch, B. M.

    1987-01-01

    A scientific investigation of the physics of the solar atmosphere, which uses the techniques of high resolution soft X-ray spectroscopy and high resolution UV imagery, is described. The experiments were conducted during a series of three sounding rocket flights. All three flights yielded excellent images in the UV range, showing unprecedented spatial resolution. The second flight recorded the X-ray spectrum of a solar flare, and the third that of an active region. A normal incidence multi-layer mirror was used during the third flight to make the first astronomical X-ray observations using this new technique.

  14. Gridded ionization chamber for detection of x-ray wave activity in tokamak plasmas

    NASA Astrophysics Data System (ADS)

    Goldman, M. A.; Hill, K. W.; Moshey, E. A.; Sauthoff, N. R.; von Goeler, S.

    1985-03-01

    In order to carry out x-ray observations of magnetohydrodynamic wave activity of the plasma during DD and DT (deuterium-beam-heated deuterium and tritium plasmas, respectively) operation of the Tokamak Fusion Test Reactor (TFTR), we will need detectors not susceptible to nuclear radiation damage. We have investigated the use of gridded ionization chambers as fast nondamageable x-ray detectors. A prototype chamber is described which was tested on the PDX tokamak. These tests and laboratory tests with a pulsed x-ray source suggest that the detector has sufficient sensitivity and speed for the required measurements.

  15. Gridded ionization chamber for detecion of x-ray wave activity in tokamak plasmas

    SciTech Connect

    Goldman, M.A.; Hill, K.W.; Moshey, E.A.; Sauthoff, N.R.; von Goeler, S.

    1982-11-01

    In order to carry out X-ray observations of magnetohydrodynamic wave activity of the plasma during DD and DT (deuterium-beam-heated deuterium and tritium plasmas, respectively) operation of the Tokamak Fusion Test Reactor (TFTR), we will need detectors not susceptible to nuclear radiation damage. We have investigated the use of gridded ionization chambers as fast nondamageable X-ray detectors. A prototype chamber is described, which was tested on the PDX tokamak. These tests and laboratory tests with a pulsed X-ray source suggest that the detector has sufficient sensitivity and speed for the required measurements.

  16. Elementary Analysis of a Cometary Surface - the Alpha Particle X-Ray Spectrometer APXS on the Rosetta Mission to Comet 67P/CHURYUMOV-GERASIMENKO

    NASA Astrophysics Data System (ADS)

    Schmanke, Dirk; Economou, Thanasis; Brueckner, Johannes; Gellert, Ralf; Rodionov, Daniel; Klingelhoefer, Goestar; Girones Lopez, Jordi; Uston, Lionel D.

    to recharge the lander batteries. During these operations the Rosetta probe will escort the comet and the lander along the comets trajectory around the sun. As long as possible APXS and the other instruments will continue to repeat their measurements to monitor the changes and rising activity of the comet. This will shed light on state, composition, evolution and the origin of comets and the solar system. Acknowledgements: This project is funded by the German Space Agency DLR under contracts 50 QP 0404 and 50 QP 0902. References: G. Klingelhöfer, J. Brückner, C. d'Uston, R. Gellert, and R. Rieder, The Rosetta Alpha Particle X-ray Spectrometer (APXS), Space Science Reviews, Vol.128 (2007) 383-396; doi:10.1007/s11214-006-9137-3

  17. X-ray refelection from photoionized media in active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Zycki, Piotr T.; Krolik, Julian H.; Zdziarski, Andrzej A.; Kallman, Timothy R.

    1994-01-01

    We calculate the spectrum of X-ray radiation and reprocessed by a partly ionized optically thick medium in an active galactic nucleus. We self-consistently calculate the ionization balance and thermal balance in the medium along with the distribution of X-ray intensity with optical depth. In addition to absorption or scattering of the incident X-rays, we also compute the spectrum of X-rays emitted by the material, including lines, edges, and bremsstrahlung. The albedo of the medium depends primarily on the X-ray ionization parameter (ratio of incident flux to gas density, zeta(sub Chi), and secondarily on the UV flux generated by dissipation inside the disk; we locate the critical range of zeta(sub Chi) over which the albedo increases from small to nearly unity. While the continuum reflection is very weak below 10 keV when zeta(sub Chi) is small, significnat fluxes are emitted in atomic lines and edges in this energy range. In the limit of large zeta(sub Chi), the albedo below 10 keV increases, but reflection in this band is never gray: some photoelectric absorption remains up to rather large values of zeta(sub Chi), while at still higher values, inverse Compton scattering amplifies the soft X-ray flux. These features are sufficiently sharp that current and near-future X-ray experiments should permit diagnostic measures of zeta(sub Chi).

  18. A new toroidal grating spectrometer for the soft x-ray region

    NASA Astrophysics Data System (ADS)

    Aton, T.; Franck, C.; Källne, E.; Schnatterly, S.; Zutavern, F.

    1980-05-01

    We have developed toroidal grating instrument using holography aberration corrected gratings to give a flat field focus and cover the wavelength region 16-625 Å. The spectrometer uses four interchangeable gratings as analysers and a self scanning silicon array as detector. The sample chamber is a bakeable UHV system with LEED and Auger surface analysis equipment to characterize the sample surface.

  19. X-ray and infrared diagnostics of nearby active galactic nuclei with MAXI and AKARI

    NASA Astrophysics Data System (ADS)

    Isobe, Naoki; Kawamuro, Taiki; Oyabu, Shinki; Nakagawa, Takao; Baba, Shunsuke; Yano, Kenichi; Ueda, Yoshihiro; Toba, Yoshiki

    2016-10-01

    Nearby active galactic nuclei were diagnosed in the X-ray and mid-to-far infrared wavelengths with Monitor of All-sky X-ray Image (MAXI) and the Japanese infrared observatory AKARI, respectively. One hundred of the X-ray sources listed in the second release of the MAXI all-sky X-ray source catalog are currently identified as non-blazar-type active galactic nuclei. These include 95 Seyfert galaxies and 5 quasars, and they are composed of 73 type-1 and 27 type-2 objects. The AKARI all-sky survey point source catalog was searched for their mid- and far-infrared counterparts at 9, 18, and 90 μm. As a result, 69 Seyfert galaxies in the MAXI catalog (48 type-1 and 21 type-2) were found to be detected with AKARI. The X-ray (3-4 keV and 4-10 keV) and infrared luminosities of these objects were investigated, together with their color information. Adopting the canonical photon index, Γ = 1.9, of the intrinsic X-ray spectrum of the Seyfert galaxies, the X-ray hardness ratio between the 3-4 and 4-10 keV ranges derived with MAXI was roughly converted into the absorption column density. After the X-ray luminosity was corrected for absorption from the estimated column density, the well-known X-ray-to-infrared luminosity correlation was confirmed, at least in the Compton-thin regime. In contrast, NGC 1365, the only Compton-thick object in the MAXI catalog, was found to deviate from the correlation toward a significantly lower X-ray luminosity by nearly an order of magnitude. It was verified that the relation between the X-ray hardness below 10 keV and X-ray-to-infrared color acts as an effective tool to pick up Compton-thick objects. The difference in the infrared colors between the type-1 and type-2 Seyfert galaxies and its physical implication on the classification and unification of active galactic nuclei are briefly discussed.

  20. X-ray observations of EX Hydrae with the Einstein Solid State Spectrometer

    NASA Technical Reports Server (NTRS)

    Singh, Jyoti; Swank, Jean

    1993-01-01

    Einstein SSS X-ray observations of the eclipsing intermediate polar EX Hya are presented. The SSS data have a better resolution at energies extending below 2 keV than do the EXOSAT data. These data reveal the presence of a soft component with a temperature of about 0.74 keV. The phase-resolved data can be fitted to a model of two-temperature thermal plasma with a single absorber, with the result that only the normalization varies with phase. This suggests that part of the soft component might become occulted at minimum. If we assume that the reduction in the flux occurs due to the photoelectric absorption, we find that a high-density material covering only about 40 percent of the emission can fit the data equally well. The EXOSAT and Ginga data of this source favor the accretion curtain model rather than the occultation model. We modify the accretion curtain model by assuming that the modulation is caused by an absorber which partially covers the accreting column at the minimum of the 67-min pulse. An emission line at 1.72 keV is present in the data. The equivalent width of this line varies in phase with the continuum. We associate this line with Si fluorescence.

  1. Lead iodide X-ray and gamma-ray spectrometers for room and high temperature operation

    SciTech Connect

    Hermon, H.; James, R.B.; Cross, E.

    1997-02-01

    In this study, we report on the results of the investigation of lead iodide material properties. The effectiveness of zone refining purification methods on the material purity is determined by ICP-MS and ICP-OES and correlated to the electrical and physical material properties. We show that this zone refining method is very efficient in removing impurities from lead iodide and we also determine the segregation coefficient for some of these impurities. Triple axis x- ray diffraction (TAD) analysis has been used to determine the crystalline perfection of the lead iodide after applying various cutting, etching, and fabrication methods. The soft lead iodide crystal was found to be damaged when cleaved by a razor blade, but by using a diamond wheel saw, followed by etching, the crystallinity of the material was improved, as observed by TAD. Low temperature photoluminescence also indicates an improvement in the material properties of the purified lead iodide. Electrical properties of lead iodide such as carrier mobility, were calculated based on carrier- phonon scattering. The results for the electrical properties were in good agreement with the experimental data.

  2. Science Goals and First Light Analysis from the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat

    NASA Astrophysics Data System (ADS)

    Caspi, Amir; Woods, Thomas N.; Warren, Harry; Chamberlin, Phillip C.; Jones, Andrew; Mason, James; McTiernan, James; Moore, Christopher; Palo, Scott; Solomon, Stanley

    2016-05-01

    The Miniature X-ray Solar Spectrometer (MinXSS) is a 3U CubeSat with deployment from the ISS planned in Q2 2016. Its goal is to measure the solar soft X-ray (SXR) spectral irradiance, an observational signature of hot plasma in the solar corona. Over the last few decades, there have been very few spectrally resolved observations from ~0.2 to ~4 keV (~0.3-6 nm). This range is sensitive to high-temperature plasma and contains many spectral lines (e.g., Mg, Si, Fe, S, Ar), the abundances of which probe plasma transport and provide valuable constraints on plasma heating mechanisms during both flares and quiescence. This solar SXR emission is primarily absorbed in the E-region of Earth's ionosphere, and the subsequently driven dynamical processes are still poorly understood, in large part because the energy distribution of the incident SXRs is not yet well characterized.MinXSS flies a miniature commercial off-the-shelf soft X-ray (SXR) spectrometer, the Amptek X123-SDD. The silicon drift detector has 0.5 mm fully depleted thickness and a 25 mm^2 physical area, with a ~16 micron Be entrance window; with on-board thermoelectric cooling and pulse pile-up rejection, it is sensitive to solar SXRs from ~0.5 to 30 keV with ~0.15 keV FWHM resolution. MinXSS also includes a broadband SXR photometer, providing an integrated intensity over a similar energy range for comparison, cross-calibration, and additional data, especially useful during more intense flares at the upper end of the X123 dynamic range.We present the MinXSS science goals for studying hot plasma in the solar corona, including impulsive flare heating and quiescent coronal heating, and the impact of the resultant SXR emission on Earth's ionosphere, thermosphere, and mesosphere. We present analysis of MinXSS first light results (depending on deployment date from the ISS), as well as modeling and predictions of future observations over the MinXSS 6-12 month mission lifetime.

  3. Construction of a magnetic bottle spectrometer and its application to pulse duration measurement of X-ray laser using a pump-probe method

    SciTech Connect

    Namba, S.; Hasegawa, N.; Kishimoto, M.; Nishikino, M.; Ishino, M.; Kawachi, T.

    2015-11-15

    To characterize the temporal evolution of ultrashort X-ray pulses emitted by laser plasmas using a pump-probe method, a magnetic bottle time-of-flight electron spectrometer is constructed. The design is determined by numerical calculations of a mirror magnetic field and of the electron trajectory in a flight tube. The performance of the spectrometer is characterized by measuring the electron spectra of xenon atoms irradiated with a laser-driven plasma X-ray pulse. In addition, two-color above-threshold ionization (ATI) experiment is conducted for measurement of the X-ray laser pulse duration, in which xenon atoms are simultaneously irradiated with an X-ray laser pump and an IR laser probe. The correlation in the intensity of the sideband spectra of the 4d inner-shell photoelectrons and in the time delay of the two laser pulses yields an X-ray pulse width of 5.7 ps, in good agreement with the value obtained using an X-ray streak camera.

  4. Construction of a magnetic bottle spectrometer and its application to pulse duration measurement of X-ray laser using a pump-probe method

    NASA Astrophysics Data System (ADS)

    Namba, S.; Hasegawa, N.; Kishimoto, M.; Nishikino, M.; Ishino, M.; Kawachi, T.

    2015-11-01

    To characterize the temporal evolution of ultrashort X-ray pulses emitted by laser plasmas using a pump-probe method, a magnetic bottle time-of-flight electron spectrometer is constructed. The design is determined by numerical calculations of a mirror magnetic field and of the electron trajectory in a flight tube. The performance of the spectrometer is characterized by measuring the electron spectra of xenon atoms irradiated with a laser-driven plasma X-ray pulse. In addition, two-color above-threshold ionization (ATI) experiment is conducted for measurement of the X-ray laser pulse duration, in which xenon atoms are simultaneously irradiated with an X-ray laser pump and an IR laser probe. The correlation in the intensity of the sideband spectra of the 4d inner-shell photoelectrons and in the time delay of the two laser pulses yields an X-ray pulse width of 5.7 ps, in good agreement with the value obtained using an X-ray streak camera.

  5. An active M star with X-ray double flares disguised as an ultra-luminous X-ray source

    NASA Astrophysics Data System (ADS)

    Guo, Jin-Cheng; Liu, Ji-Feng; Wang, Song; Wu, Yue; Qin, Yu-Xiang

    2016-02-01

    Here we present research on an ultra-luminous X-ray source (ULX) candidate 2XMM J140229.91+542118.8. The X-ray light curves of this ULX candidate in M101 exhibit features of a flare star. More importantly, the Chandra light curve displays unusual X-ray double flares, which is comprised of two close peaks. The X-ray (0.3-11.0 keV) flux of the first peak was derived from the two-temperature APEC model as ˜ 1.1 ± 0.1 × 10-12 erg cm-2 s-1. The observed flux at its first peak increased by about two orders of magnitude in X-ray as compared to quiescence. The slope of the second fast decay phase is steeper than the slope of the first fast decay phase, indicating that the appearance of a second flare accelerated the cooling of the first flare in a way we do not understand yet. We also observed its optical counterpart using a 2.16 m telescope administered by National Astronomical Observatories, Chinese Academy of Sciences. By optical spectral fitting, it is confirmed to be a late type dMe2.5 star. According to the spectral type and apparent magnitude of its optical counterpart, we estimate the photometric distance to be ˜ 133.4 ± 14.2 pc. According to the X-ray spectral fitting, a possible explanation is provided. However, more similar close double flares are needed to confirm whether this accelerated cooling event is a unique coincidence or a common physical process during double flaring.

  6. The SPARX Project: R & D Activity Towards X-Rays FEL Sources

    SciTech Connect

    Alesini, D.; Bellaveglia, M.; Bertolucci, S.; Biagini, M.E.; Boni, R.; Boscolo, M.; Castellano, M.; Clozza, A.; Di Pirro, G.; Drago, A.; Esposito, A.; Ferrario, M.; Filippetto, D.; Fusco, V.; Gallo, A.; Ghigo, A.; Guiducci, S.; Incurvati, M.; Ligi, C.; Marcellini, F.; Migliorati, M.; /Frascati /ENEA, Frascati /INFN, Milan /INFN, Rome /INFN, Rome2 /Milan Polytechnic /UCLA /SLAC

    2005-08-05

    SPARX is an evolutionary project proposed by a collaboration among ENEA-INFN-CNR-Universita di Roma Tor Vergata aiming at the construction of a FELSASE X-ray source in the Tor Vergata Campus. The first phase of the SPARX project, funded by Government Agencies, will be focused on R&D activity on critical components and techniques for future X-ray facilities as described in this paper.

  7. Photonuclear reaction based high-energy x-ray spectrometer to cover from 2 MeV to 20 MeV

    SciTech Connect

    Sakata, S. Arikawa, Y.; Kojima, S.; Ikenouchi, T.; Nagai, T.; Abe, Y.; Inoue, H.; Morace, A.; Utsugi, M.; Nishimura, H.; Nakai, M.; Shiraga, H.; Fujioka, S.; Azechi, H.; Kato, R.

    2014-11-15

    A photonuclear-reaction-based hard x-ray spectrometer is developed to measure the number and energy spectrum of fast electrons generated by interactions between plasma and intense laser light. In this spectrometer, x-rays are converted to neutrons through photonuclear reactions, and the neutrons are counted with a bubble detector that is insensitive to x-rays. The spectrometer consists of a bundle of hard x-ray detectors that respond to different photon-energy ranges. Proof-of-principle experiment was performed on a linear accelerator facility. A quasi-monoenergetic electron bunch (N{sub e} = 1.0 × 10{sup −6} C, E{sub e} = 16 ± 0.32 MeV) was injected into a 5-mm-thick lead plate. Bremsstrahlung x-rays, which emanate from the lead plate, were measured with the spectrometer. The measured spectral shape and intensity agree fairly well with those computed with a Monte Carlo simulation code. The result shows that high-energy x-rays can be measured absolutely with a photon-counting accuracy of 50%–70% in the energy range from 2 MeV to 20 MeV with a spectral resolution (Δhν/hν) of about 15%. Quantum efficiency of this spectrometer was designed to be 10{sup −7}, 10{sup −4}, 10{sup −5}, respectively, for 2–10, 11–15, and 15–25 MeV of photon energy ranges.

  8. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Urgiles, E.; Wilcox, J. Z.; Toda, R.; Crisp, J.; George, T.

    2005-01-01

    Introduction: This paper describes the progress in data acquisition and establishing the observational capability of the AEXS instrument. The AEXS is a miniature instrument[1-4] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam which enables nondestructive evaluation of sample surfaces in planetary ambient atmospheres. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum of the AEXS source from the outside ambient atmosphere. Thus eliminating the need for a vacuum pumped sample chamber as is common in all laboratory SEM s. The transmitted electrons impinge on the sample exciting XRF spectra from the irradiated spot on in-situ or collected samples with sub-mm to cm-scale spatial resolution at Mars atmospheric pressure. The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an XRF detection and analyzer system, and a high voltage power supply. The XRF data are analyzed to determine the elemental abundance for the irradiated spots. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the viability of microfabricated membranes, 2) assembling AEXS setups with increasingly integrated functional components, and 3) simulating the AEXS observational capabilities. The development of the instrument is described in detail in the poster paper[4] at this conference. This paper focuses on describing the progress of the AEXS instrument to acquire XRF data and using commercially available software to analyze the data streams and determine the accuracy, precision and resolution of the analysis compared to the certified elemental abundance.

  9. Robust x-ray image segmentation by spectral clustering and active shape model.

    PubMed

    Wu, Jing; Mahfouz, Mohamed R

    2016-07-01

    Extraction of bone contours from x-ray radiographs plays an important role in joint space width assessment, preoperative planning, and kinematics analysis. We present a robust segmentation method to accurately extract the distal femur and proximal tibia in knee radiographs of varying image quality. A spectral clustering method based on the eigensolution of an affinity matrix is utilized for x-ray image denoising. An active shape model-based segmentation method is employed for robust and accurate segmentation of the denoised x-ray images. The performance of the proposed method is evaluated with x-ray images from the public-use dataset(s), the osteoarthritis initiative, achieving a root mean square error of [Formula: see text] for femur and [Formula: see text] for tibia. The results demonstrate that this method outperforms previous segmentation methods in capturing anatomical shape variations, accounting for image quality differences and guiding accurate segmentation. PMID:27660806

  10. The prospects of X-ray polarimetry for Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Goosmann, René W.

    2016-08-01

    Polarimetry at optical and other wavelength continues to play an important role in our struggle to develop (super-)unification schemes for active galactic nuclei (AGN). Therefore, radio-loud and radio-quiet AGN are important targets for the future small and medium-size X-ray polarimetry missions that are currently under phase A study at NASA and ESA. After briefly pointing out the detection principle of polarization imaging in the soft X-ray band, I am going to review the prospects of X-ray polarimetry for our understanding of AGN ejection (winds and blazar jets) and accretion flows (accretion disk and corona). The X-ray polarimetry signal between 2 and 8 keV is going to give us important new constraints on the geometry of the central engine as well as on the acceleration effects in AGN jets, in particular when combined with spectral and/or polarization information at other wavelengths.

  11. Intense X-ray flares from active stellar systems - EV Lacertae and HD 8357

    NASA Technical Reports Server (NTRS)

    Ambruster, C.; Snyder, W. A.; Wood, K. S.

    1984-01-01

    The HEAO A-1 Sky Survey Experiment included X-ray data used to define light curves for the flare star EV Lac and for X-ray flares observed in the binary system HD 8357. The data were taken during flare events and were detailed enough to calculate the flare rates and flaring luminosities. The peak luminosities during flares were several times the luminosities in normal X-ray flares emitted by the objects. Peak luminosities reached 30-50 times the normal variations and were associated with an order of magnitude increase in energy output. EV Lac was sufficiently active to be recommended for inclusion in future X-ray monitoring programs.

  12. Atmospheric Electron-induced X-Ray Spectrometer (AEXS) Instrument Development

    NASA Technical Reports Server (NTRS)

    Wilcox, J. Z.; Urgiles, E.; Toda, R.; George, T.; Crisp, J.

    2005-01-01

    Instrument Development: The membrane properties were investigated in detail due to its critical role. A series of experiments determined that our designed membranes have high electron transmission, yet are capable of isolating high vacuum, are able to withstand differential pressure in excess of one atmosphere, survive vibrational shocks of a magnitude to be expected during a planetary mission. Our initial work has been with a 10 keV source and a 200 nm thick Silicon Nitride (SiN) encapsulation membrane micro-fabricated within a Si support frame (1.5 mm x 1.5 mm window openings. Fig 2 compares the spectra taken with the 10 keV source with spectra taken within SEM. Introduction: This paper describes the progress in the development of the AEXS instrument in our laboratory at JPL. The AEXS is a novel miniature instrument[1-3] based on the excitation of characteristic X-Ray Fluorescence (XRF) and luminescence spectra using a focused electron beam, for non-destructive evaluation of surfaces of samples in planetary ambient atmosphere. In situ operation is obtained through the use of a thin electron transmissive membrane to isolate the vacuum within the AEXS electron source from the outside ambient atmosphere. The impinging electrons excite XRF spectra from the irradiated spots on samples in external atmosphere with high-to-medium (sub-mm to cm-scale) spatial resolution at Mars atmospheric pressure. The XRF spectra are analyzed using an energy-dispersive detector to determine surface elemental composition, or in the case of electron-induced luminescence to identify unusual formations on surface that cathodo-luminescence (CL). The AEXS system (Fig 1) consists of a high-energy (>10keV) electron gun encapsulated by the isolation membrane, an EDX detection and analyzer system to determine the elemental abundance, an optional CL detection system, and a high voltage power supply. The approach to demonstrating a proof of concept of the AEXS has been through 1) demonstrating the

  13. Wavelength-dispersive total-reflection X-ray fluorescence with an efficient Johansson spectrometer and an undulator X-ray source: detection of 10-16 g-level trace metals.

    PubMed

    Sakurai, Kenji; Eba, Hiromi; Inoue, Katsuaki; Yagi, Naoto

    2002-09-01

    The present paper reports significant enhancement of the detection power for total-reflection X-ray fluorescence (TXRF). The employment of an efficient wavelength-dispersive spectrometer rather than a conventional Si(Li) detector, as well as the use of a quasi-monochromatic undulator X-ray source, completely changed the quality of X-ray florescence spectra. The energy resolution is 20 times better, which effectively contributes to reducing the low-energy tail of the scattering background and to separating neighboring X-ray florescence peaks. Another advantage is its capability with respect to high-counting-rate measurements, which ensure the detection of weak signals from trace materials. The absolute and relative detection limit for nickel are 3.1 x 10(-16) g and 3.1 ppt (pg/g) for a 0.1-microL droplet of pure water, respectively, which is nearly 50 times better than the current best data achieved by conventional energy-dispersive TXRF using a Si(Li) detector system. PMID:12236366

  14. X-ray structure analysis of a metalloprotein with enhanced active-site resolution using in situ x-ray absorption near edge structure spectroscopy.

    PubMed

    Arcovito, Alessandro; Benfatto, Maurizio; Cianci, Michele; Hasnain, S Samar; Nienhaus, Karin; Nienhaus, G Ulrich; Savino, Carmelinda; Strange, Richard W; Vallone, Beatrice; Della Longa, Stefano

    2007-04-10

    X-ray absorption spectroscopy is exquisitely sensitive to the coordination geometry of an absorbing atom and therefore allows bond distances and angles of the surrounding atomic cluster to be measured with atomic resolution. By contrast, the accuracy and resolution of metalloprotein active sites obtainable from x-ray crystallography are often insufficient to analyze the electronic properties of the metals that are essential for their biological functions. Here, we demonstrate that the combination of both methods on the same metalloprotein single crystal yields a structural model of the protein with exceptional active-site resolution. To this end, we have collected an x-ray diffraction data set to 1.4-A resolution and Fe K-edge polarized x-ray absorption near edge structure (XANES) spectra on the same cyanomet sperm whale myoglobin crystal. The XANES spectra were quantitatively analyzed by using a method based on the multiple scattering approach, which yielded Fe-heme structural parameters with +/-(0.02-0.07)-A accuracy on the atomic distances and +/-7 degrees on the Fe-CN angle. These XANES-derived parameters were subsequently used as restraints in the crystal structure refinement. By combining XANES and x-ray diffraction, we have obtained an cyanomet sperm whale myoglobin structural model with a higher precision of the bond lengths and angles at the active site than would have been possible with crystallographic analysis alone.

  15. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility

    SciTech Connect

    Reverdin, Charles; Caillaud, T.; Gilleron, F.; Pain, J. C.; Silvert, V.; Soullie, G.; Villette, B.; Thais, Frederic; Loisel, Guillaume; Blenski, T.; Poirier, M.; Busquet, M.; Bastiani-Ceccotti, S.; Serres, F.; Ducret, J. E.; Foelsner, W.; Gilles, D.; Turck-Chieze, S.

    2012-10-15

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution {approx} 50. It has been used at the LULI-2000 laser facility at Ecole Polytechnique (France) to measure the {Delta}n = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  16. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility.

    PubMed

    Reverdin, Charles; Thais, Frédéric; Loisel, Guillaume; Busquet, M; Bastiani-Ceccotti, S; Blenski, T; Caillaud, T; Ducret, J E; Foelsner, W; Gilles, D; Gilleron, F; Pain, J C; Poirier, M; Serres, F; Silvert, V; Soullie, G; Turck-Chieze, S; Villette, B

    2012-10-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented. PMID:23126955

  17. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facilitya)

    NASA Astrophysics Data System (ADS)

    Reverdin, Charles; Thais, Frédéric; Loisel, Guillaume; Busquet, M.; Bastiani-Ceccotti, S.; Blenski, T.; Caillaud, T.; Ducret, J. E.; Foelsner, W.; Gilles, D.; Gilleron, F.; Pain, J. C.; Poirier, M.; Serres, F.; Silvert, V.; Soullie, G.; Turck-Chieze, S.; Villette, B.

    2012-10-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ⟨E/δE⟩ ˜ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  18. Long-term X-Ray Variability of Typical Active Galactic Nuclei in the Distant Universe

    NASA Astrophysics Data System (ADS)

    Yang, G.; Brandt, W. N.; Luo, B.; Xue, Y. Q.; Bauer, F. E.; Sun, M. Y.; Kim, S.; Schulze, S.; Zheng, X. C.; Paolillo, M.; Shemmer, O.; Liu, T.; Schneider, D. P.; Vignali, C.; Vito, F.; Wang, J.-X.

    2016-11-01

    We perform long-term (≈15 years, observed-frame) X-ray variability analyses of the 68 brightest radio-quiet active galactic nuclei (AGNs) in the 6 Ms Chandra Deep Field-South survey; the majority are in the redshift range of 0.6–3.1, providing access to penetrating rest-frame X-rays up to ≈10–30 keV. Of the 68 sources, 24 are optical spectral type I AGNs, and the rest (44) are type II AGNs. The timescales probed in this work are among the longest for X-ray variability studies of distant AGNs. Photometric analyses reveal widespread photon flux variability: 90% of AGNs are variable above a 95% confidence level, including many X-ray obscured AGNs and several optically classified type II quasars. We characterize the intrinsic X-ray luminosity ({L}{{X}}) and absorption ({N}{{H}}) variability via spectral fitting. Most (74%) sources show {L}{{X}} variability; the variability amplitudes are generally smaller for quasars. A Compton-thick candidate AGN shows variability of its high-energy X-ray flux, indicating the size of reflecting material to be ≲0.3 pc. {L}{{X}} variability is also detected in a broad absorption line quasar. The {N}{{H}} variability amplitude for our sample appears to rise as time separation increases. About 16% of sources show {N}{{H}} variability. One source transitions from an X-ray unobscured to obscured state, while its optical classification remains type I; this behavior indicates the X-ray eclipsing material is not large enough to obscure the whole broad-line region.

  19. X-Ray Emission from Active Galactic Nuclei with Intermediate-Mass Black Holes

    NASA Astrophysics Data System (ADS)

    Dewangan, G. C.; Mathur, S.; Griffiths, R. E.; Rao, A. R.

    2008-12-01

    We present a systematic X-ray study of eight active galactic nuclei (AGNs) with intermediate-mass black holes (MBH ~ 8-95 × 104 M⊙) based on 12 XMM-Newton observations. The sample includes the two prototype AGNs in this class—NGC 4395 and POX 52 and six other AGNs discovered with the Sloan Digitized Sky Survey. These AGNs show some of the strongest X-ray variability, with the normalized excess variances being the largest and the power density break timescales being the shortest observed among radio-quiet AGNs. The excess-variance-luminosity correlation appears to depend on both the BH mass and the Eddington luminosity ratio. The break timescale-black hole mass relations for AGN with IMBHs are consistent with that observed for massive AGNs. We find that the FWHM of the Hβ/Hα line is uncorrelated with the BH mass, but shows strong anticorrelation with the Eddington luminosity ratio. Four AGNs show clear evidence for soft X-ray excess emission (kTin ~ 150-200 eV). X-ray spectra of three other AGNs are consistent with the presence of the soft excess emission. NGC 4395 with lowest L/LEdd lacks the soft excess emission. Evidently small black mass is not the primary driver of strong soft X-ray excess emission from AGNs. The X-ray spectral properties and optical-to-X-ray spectral energy distributions of these AGNs are similar to those of Seyfert 1 galaxies. The observed X-ray/UV properties of AGNs with IMBHs are consistent with these AGNs being low-mass extensions of more massive AGNs, those with high Eddington luminosity ratio looking more like narrow-line Seyfert 1 s and those with low L/LEdd looking more like broad-line Seyfert 1 galaxies.

  20. Design of a 3-Stage ADR for the Soft X-Ray Spectrometer Instrument on the Astro-H Mission

    NASA Technical Reports Server (NTRS)

    Shirron, Peter J.; Kimball, Mark O.; Wegel, Donald C.; Canavan, Edgar R.; DiPirro, Michael J.

    2011-01-01

    The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument, whose 36-pixel detector array of ultra-sensitive x-ray microcalorimeters requires cooling to 50 mK. This will be accomplished using a 3-stage adiabatic demagnetization refrigerator (ADR). The design is dictated by the need to operate with full redundancy with both a superfluid helium dewar at 1.3 K or below, and with a 4.5 K Joule-Thomson (JT) cooler. The ADR is configured as a 2-stage unit that is located in a well in the helium tank, and a third stage that is mounted to the top of the helium tank. The third stage is directly connected through two heat switches to the JT cooler and the helium tank, and manages heat flow between the two. When liquid helium is present, the 2-stage ADR operates in a single-shot manner using the superfluid helium as a heat sink. The third stage may be used independently to reduce the time-average heat load on the liquid to extend its lifetime. When the liquid is depleted, the 2nd and 3rd stages operate as a continuous ADR to maintain the helium tank at as low a temperature as possible - expected to be 1.2 K - and the 1st stage cools from that temperature as a single-stage, single-shot ADR. The ADR s design and operating modes are discussed, along with test results of the prototype 3-stage ADR.

  1. Analysis of nearly simultaneous X-ray and optical observations of active galactic nuclei

    NASA Astrophysics Data System (ADS)

    Webb, James Raymond

    Rosemary Hill optical and EINSTEIN X-ray observations of a sample of 36 active galactic nuclei (AGN) were reduced and analyzed. Seventy-two X-ray observations of these sources were reduced, nineteen of which yielded spectral information. Of these spectral observations, significant hydrogen column densities above the galactic value were required for nine of the eleven sources which were observed more than once by EINSTEIN. Correlations between the X-ray and optical luminosities were investigated using the Jefferys method of least squares. This method allows for errors in both variables. The results indicate a strong correlation between the X-ray and optical luminosities for the entire sample. Division of the sample into groups with similar optical variability characteristics show that the less violently violent variable AGN are more highly correlated than the violently variable blazars. Infrared and radio observations were combined with the X-ray and optical observations of six AGN. These sources were modelled in terms of the synchrotron-self-Compton model. The turnover frequency falls between the infrared and radio data and reliable estimates of this parameter are difficult to estimate. Therefore the results were found as a function of the turnover frequency. Four sources required relativistic bulk motion or beaming. Multifrequency spectra made at different times for one individual source, 0235+164, required different amounts of beaming to satisfy the X-ray observations. Sizes of the emitting regions for the sources modelled ranged from 0.5 parsec to 1.0 parsec.

  2. ITER-relevant calibration technique for soft x-ray spectrometer

    SciTech Connect

    Rzadkiewicz, J.; Jakubowska, K.; KsiaPzek, I.; Zastrow, K-D.; Lawson, K. D.; Collaboration: JET EFDA Contributors

    2010-10-15

    The ITER-oriented JET research program brings new requirements for the low-Z impurity monitoring, in particular for the Be - the future main wall component of JET and ITER. Monitoring based on Bragg spectroscopy requires an absolute sensitivity calibration, which is challenging for large tokamaks. This paper describes both ''component-by-component'' and ''continua'' calibration methods used for the Be IV channel (75.9 A of the Bragg rotor spectrometer deployed on JET. The calibration techniques presented here rely on multiorder reflectivity calculations and measurements of continuum radiation emitted from helium plasmas. These offer excellent conditions for the absolute photon flux calibration due to their low level of impurities. It was found that the component-by-component method gives results that are four times higher than those obtained by means of the continua method. A better understanding of this discrepancy requires further investigations.

  3. ITER-relevant calibration technique for soft x-ray spectrometer.

    PubMed

    Rzadkiewicz, J; Książek, I; Zastrow, K-D; Coffey, I H; Jakubowska, K; Lawson, K D

    2010-10-01

    The ITER-oriented JET research program brings new requirements for the low-Z impurity monitoring, in particular for the Be—the future main wall component of JET and ITER. Monitoring based on Bragg spectroscopy requires an absolute sensitivity calibration, which is challenging for large tokamaks. This paper describes both “component-by-component” and “continua” calibration methods used for the Be IV channel (75.9 Å) of the Bragg rotor spectrometer deployed on JET. The calibration techniques presented here rely on multiorder reflectivity calculations and measurements of continuum radiation emitted from helium plasmas. These offer excellent conditions for the absolute photon flux calibration due to their low level of impurities. It was found that the component-by-component method gives results that are four times higher than those obtained by means of the continua method. A better understanding of this discrepancy requires further investigations.

  4. High resolution spectrometer for extended x-ray absorption fine structure measurements in the 6 keV to 15 keV energy range

    NASA Astrophysics Data System (ADS)

    Seely, J. F.; Hudson, L. T.; Henins, Albert; Feldman, U.

    2016-11-01

    A Cauchois transmission-crystal spectrometer has been developed with high crystal resolving power in the 6 keV-15 keV energy range and sufficient sensitivity to record single-shot spectra from the Lawrence Livermore National Laboratory (LLNL) Titan laser and other comparable or more energetic lasers. The spectrometer capabilities were tested by recording the W L transitions from a laboratory source and the extended x-ray absorption fine structure (EXAFS) spectrum through a Cu foil.

  5. Inline spectrometer for shot-by-shot determination of pulse energies of a two-color X-ray free-electron laser.

    PubMed

    Tamasaku, Kenji; Inubushi, Yuichi; Inoue, Ichiro; Tono, Kensuke; Yabashi, Makina; Ishikawa, Tetsuya

    2016-01-01

    An inline spectrometer has been developed to monitor shot-by-shot pulse energies of a two-color X-ray beam. A thin film of diamond allows inline operation with minimum absorption. The absolute pulse energy for each color is determined by the inline spectrometer combined with a total pulse-energy monitor. A negative correlation is found between the two-color pulse energies.

  6. Minimalist coupled evolution model for stellar X-ray activity, rotation, mass loss, and magnetic field

    NASA Astrophysics Data System (ADS)

    Blackman, Eric G.; Owen, James E.

    2016-05-01

    Late-type main-sequence stars exhibit an X-ray to bolometric flux ratio that depends on {tilde{R}o}, the ratio of rotation period to convective turnover time, as {tilde{R}o}^{-ζ } with 2 ≤ ζ ≤ 3 for {tilde{R}o} > 0.13, but saturates with |ζ| < 0.2 for {tilde{R}o} < 0.13. Saturated stars are younger than unsaturated stars and show a broader spread of rotation rates and X-ray activity. The unsaturated stars have magnetic fields and rotation speeds that scale roughly with the square root of their age, though possibly flattening for stars older than the Sun. The connection between faster rotators, stronger fields, and higher activity has been established observationally, but a theory for the unified time-evolution of X-ray luminosity, rotation, magnetic field and mass loss that captures the above trends has been lacking. Here we derive a minimalist holistic framework for the time evolution of these quantities built from combining a Parker wind with new ingredients: (1) explicit sourcing of both the thermal energy launching the wind and the X-ray luminosity via dynamo produced magnetic fields; (2) explicit coupling of X-ray activity and mass-loss saturation to dynamo saturation (via magnetic helicity build-up and convection eddy shredding); (3) use of coronal equilibrium to determine how magnetic energy is divided into wind and X-ray contributions. For solar-type stars younger than the Sun, we infer conduction to be a subdominant power loss compared to X-rays and wind. For older stars, conduction is more important, possibly quenching the wind and reducing angular momentum loss. We focus on the time evolution for stars younger than the Sun, highlighting what is possible for further generalizations. Overall, the approach shows promise towards a unified explanation of all of the aforementioned observational trends.

  7. The effects of radiation damage on the spectral resolution of the Chandrayaan-1 x-ray spectrometer over the full mission duration

    NASA Astrophysics Data System (ADS)

    Walker, T. E.; Smith, D. R.

    2012-07-01

    The Chandrayaan-1 X-ray Spectrometer (C1XS) was launched onboard the Indian Space Research Organisation (ISRO) Chandrayaan-1 lunar mission in October 2008. The instrument consisted of 24 swept-charge device silicon X-ray detectors providing a total collecting area of ~24 cm2, corresponding to a 14° field of view (FWHM), with the ability to measure X-rays from 0.8 - 10 keV. During the 10 months the spacecraft was located in orbit around the Moon a number of solar flare X-ray events were detected, along with calibration data from X-ray sources housed inside the movable door of the instrument. This paper presents a further study of the degradation in spectral resolution of the measured X-ray calibration lines, adding a final calibration point towards the end of mission lifetime to the known results from the midpoint of the mission, giving a more detailed analysis of the extent of the radiation damage. The radiation environment the detectors were subjected to is discussed in light of the actual radiation damage effects on the spectral resolution observed in flight.

  8. Skylab ATM/S-056 X-ray event analyzer observations versus solar flare activity: An event compilation. [tables (data)

    NASA Technical Reports Server (NTRS)

    Wilson, R. M.

    1977-01-01

    An event compilation is presented which correlates ATM/S-056 X-ray event analyzer solar observations with solar flare activity. Approximately 1,070 h of pulse height analyzed X-ray proportional counter data were obtained with the X-ray event analyzer during Skylab. During its operation, 449 flares (including 343 flare peaks) were observed. Seventy events of peak X-ray emission or = Cl were simultaneously observed by ground based telescopes, SOLRAD 9 and/or Vela, and the X-ray event analyzer. These events were observed from preflare through flare rise to peak and through flare decline.

  9. Analysis of nearly simultaneous x-ray and optical observations of active galactic nuclei

    SciTech Connect

    Webb, J.R.

    1988-01-01

    Rosemary Hill optical and EINSTEIN X-ray observations of a sample of 36 galactic nuclei (AGN) were reduced and analyzed. Seventy-two x-ray observations of these sources were reduced, nineteen of which yielded spectral information. Of these spectra observations, significant hydrogen column densities above the galactic value were required for nine of the active galactic nuclei. X-ray variability was detected in eight of the eleven sources which were observed more than once by EINSTEIN. Correlations between the x-ray and optical luminosities were investigated using the Jefferys method of least squares. This method allows for errors in both variables. The results indicate a strong correlation between the x-ray and optical luminosities for the entire sample. Division of the sample into groups with similar optical variability characteristics show that the less violently violent variable AGN are more highly correlated than the violently variable blazars. Infrared and radio observations were combined with the x-ray and optical observations of six AGN. These sources were modelled in terms of the synchrotron-self-Compton model. The turnover frequency falls between the infrared and radio data and reliable estimates of this parameter are difficult to estimate. Therefore the results were found as a function of the turnover frequency. Four sources required relativistic bulk motion or beaming. Multifrequency spectra made at different times for one individual source, 0235+164, required different amounts of beaming to satisfy the x-ray observations. Sizes of the emitting regions for the sources modelled ranged from 0.5 parsec to 1.0 parsec.

  10. DIRECT MEASUREMENT OF THE X-RAY TIME-DELAY TRANSFER FUNCTION IN ACTIVE GALACTIC NUCLEI

    SciTech Connect

    Legg, E.; Miller, L.; Turner, T. J.; Giustini, M.; Reeves, J. N.; Kraemer, S. B.

    2012-11-20

    The origin of the observed time lags, in nearby active galactic nuclei (AGNs), between hard and soft X-ray photons is investigated using new XMM-Newton data for the narrow-line Seyfert I galaxy Ark 564 and existing data for 1H 0707-495 and NGC 4051. These AGNs have highly variable X-ray light curves that contain frequent, high peaks of emission. The averaged light curve of the peaks is directly measured from the time series, and it is shown that (1) peaks occur at the same time, within the measurement uncertainties, at all X-ray energies, and (2) there exists a substantial tail of excess emission at hard X-ray energies, which is delayed with respect to the time of the main peak, and is particularly prominent in Ark 564. Observation (1) rules out that the observed lags are caused by Comptonization time delays and disfavors a simple model of propagating fluctuations on the accretion disk. Observation (2) is consistent with time lags caused by Compton-scattering reverberation from material a few thousand light-seconds from the primary X-ray source. The power spectral density and the frequency-dependent phase lags of the peak light curves are consistent with those of the full time series. There is evidence for non-stationarity in the Ark 564 time series in both the Fourier and peaks analyses. A sharp 'negative' lag (variations at hard photon energies lead soft photon energies) observed in Ark 564 appears to be generated by the shape of the hard-band transfer function and does not arise from soft-band reflection of X-rays. These results reinforce the evidence for the existence of X-ray reverberation in type I AGN, which requires that these AGNs are significantly affected by scattering from circumnuclear material a few tens or hundreds of gravitational radii in extent.

  11. Development of wavelength-dispersive soft X-ray emission spectrometers for transmission electron microscopes--an introduction of valence electron spectroscopy for transmission electron microscopy.

    PubMed

    Terauchi, Masami; Koike, Masato; Fukushima, Kurio; Kimura, Atsushi

    2010-01-01

    Two types of wavelength-dispersive soft X-ray spectrometers, a high-dispersion type and a conventional one, for transmission electron microscopes were constructed. Those spectrometers were used to study the electronic states of valence electrons (bonding electrons). Both spectrometers extended the acceptable energy regions to higher than 2000 eV. The best energy resolution of 0.08 eV was obtained for an Al L-emission spectrum by using the high-dispersion type spectrometer. By using the spectrometer, C K-emission of carbon allotropes, Cu L-emission of Cu(1-x)Zn(x) alloys and Pt M-emission spectra were presented. The FWHM value of 12 eV was obtained for the Pt Malpha-emission peak. The performance of the conventional one was also presented for ZnS and a section specimen of a multilayer device. W-M and Si-K emissions were clearly resolved. Soft X-ray emission spectroscopy based on transmission electron microscopy (TEM) has an advantage for obtaining spectra from a single crystalline specimen with a defined crystal setting. As an example of anisotropic soft X-ray emission, C K-emission spectra of single crystalline graphite with different crystal settings were presented. From the spectra, density of states of pi- and sigma-bondings were separately derived. These results demonstrated a method to analyse the electronic states of valence electrons of materials in the nanometre scale based on TEM. PMID:20371492

  12. The Alpha-Proton-X-ray Spectrometer deployment mechanism: an anthropomorphic approach to sensor placement on Martian rocks and soil

    NASA Astrophysics Data System (ADS)

    Blomquist, Richard S.

    1995-05-01

    On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.

  13. Rapid and accurate analyses of silicon and phosphorus in plants using a portable X-ray fluorescence spectrometer.

    PubMed

    Reidinger, Stefan; Ramsey, Michael H; Hartley, Susan E

    2012-08-01

    The elemental analysis of plant material is a frequently employed tool across biological disciplines, yet accurate, convenient and economical methods for the determination of some important elements are currently lacking. For instance, digestion-based techniques are often hazardous and time-consuming and, particularly in the case of silicon (Si), can suffer from low accuracy due to incomplete solubilization and potential volatilization, whilst other methods may require large, expensive and specialised equipment. Here, we present a rapid, safe and accurate procedure for the simultaneous, nonconsumptive analysis of Si and phosphorus (P) in as little as 0.1 g dried and ground plant material using a portable X-ray fluorescence spectrometer (P-XRF). We used certified reference materials from different plant species to test the analytical performance of P-XRF and show that the analysis suffers from very little bias and that the repeatability precision of the measurements is as good as or better than that of other methods. Using this technique we were able to process and analyse 200 ground samples a day, so P-XRF could provide a particularly valuable tool for plant biologists requiring the simultaneous nonconsumptive analysis of multiple elements, including those known to be difficult to measure such as Si, in large numbers of samples.

  14. The Alpha-Proton-X-ray Spectrometer deployment mechanism: An anthropomorphic approach to sensor placement on Martian rocks and soil

    NASA Technical Reports Server (NTRS)

    Blomquist, Richard S.

    1995-01-01

    On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.

  15. Current research activities in the field of multilayer for EUV, soft x-ray and x-rays in IPOE

    NASA Astrophysics Data System (ADS)

    Wang, Zhanshan; Wang, Fengli; Zhang, Zhong; Wang, Hongchang; Wu, Wenjuan; Zhang, Shumin; Gu, Zhongxiang; Cheng, Xinbin; Wang, Bei; Qin, Shuji; Chen, Lingyan

    2006-01-01

    The present status of studies on EUV, soft x-ray and x-ray multilayer in the Institute of Precision Optical Engineering (IPOE) is briefly reviewed. With the aim of realizing a Mach-Zender interferometer working at 13.9nm, we have developed a semitransparent beam splitter with multilayer deposited on the back side of a silicon nitride membrane. On the basis of the experimental optical properties of the beam splitter, design has been performed to define the multilayer structure that provides the highest product of reflectivity and transmission. Optimized Mo/Si multilayer has been successfully deposited on the back side of a silicon nitride membrane by use of the magnetron sputtering. Measurements by means of a reflectometer in Beijing Synchrotron Radiation Facility at 13.9nm and at an angle of 7.2° provide a reflectivity of 20% and a transmission of 22%. Such a beam splitter has been used for X-ray Mach-Zender interferometer at 13.9nm. The broadband multilayer analyzer in the range between 12.4nm and 20nm is designed, and made which can deviate the Quasi-Brewster's angle several degree and show very high polarization. The main feature of our design approach is the use of an analytical solution as a starting point for direct computer search, and the desired results can be given in a reasonable time. The method can be applied in different spectral range for suitable material combination. Supermirrors with broad angular band working at different wavelength such as Cu Kα line are designed, manufactured and measured. The results show that the performance of the supermirrors is in agreement with designed data.

  16. Flat-field grating spectrometer for high-resolution soft x-ray and EUV measurements on an electron beam ion trap

    SciTech Connect

    Beiersdorfer, P; Magee, E; Trabert, E; Chen, H; Lepson, J K; Gu, M F; Schmidt, M

    2004-03-27

    A R = 44.3 m grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Angstrom up to 50 Angstrom. The instrument uses a grating with variable line spacing (about 2400 l/mm) for a flat field of view. Spectra are recorded with a back-illuminated charge-coupled device detector. The new instrument greatly improves upon the resolution achieved with existing grating spectrometers and complements crystal spectrometers at the shorter wavelengths both in terms of wavelength coverage and polarization independent reflectivity response.

  17. X-ray crystal structure of divalent metal-activated ß-xyloisdase, RS223BX

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We report the first X-ray structure of a glycoside hydrolase family 43 ß-xylosidase, RS223BX, which is strongly activated by the addition of divalent metal cations. The 2.69 Å structure reveals that the Ca2+ cation is located at the back of the active site pocket. The Ca2+ coordinates to H274 to sta...

  18. Combination of grazing incidence x-ray fluorescence with x-ray reflectivity in one table-top spectrometer for improved characterization of thin layer and implants on/in silicon wafers

    SciTech Connect

    Ingerle, D.; Schiebl, M.; Streli, C.; Wobrauschek, P.

    2014-08-15

    As Grazing Incidence X-ray Fluorescence (GIXRF) analysis does not provide unambiguous results for the characterization of nanometre layers as well as nanometre depth profiles of implants in silicon wafers by its own, the approach of providing additional information using the signal from X-ray Reflectivity (XRR) was tested. As GIXRF already uses an X-ray beam impinging under grazing incidence and the variation of the angle of incidence, a GIXRF spectrometer was adapted with an XRR unit to obtain data from the angle dependent fluorescence radiation as well as data from the reflected beam. A θ-2θ goniometer was simulated by combining a translation and tilt movement of a Silicon Drift detector, which allows detecting the reflected beam over 5 orders of magnitude. HfO{sub 2} layers as well as As implants in Silicon wafers in the nanometre range were characterized using this new setup. A just recently published combined evaluation approach was used for data evaluation.

  19. A sample of active galactic nuclei with strong soft X-ray variabilities

    NASA Astrophysics Data System (ADS)

    Bi, Da; Liu, Teng; Wang, JunXian

    2015-04-01

    Large-amplitude X-ray variation is a special feature of AGN, reflecting possible extreme change in the central engine or the absorption along the line of sight. Till now there are only a few relevant studies on individual sources or rather small samples. In this work we aim to perform a systematic study of AGNs with strong soft X-ray variations at timescale of ≳ 10 years. To build the sample, we compare the soft X-ray fluxes of AGNs measured in ROSAT All-Sky Survey (RASS) during 1990-1991 with those measured by XMM-Newton during 2000-2009. This investigation bings forth to a sample of 13 AGNs, which appeared bright in RASS era, and went into low states (flux dropped by a factor of ≳ 10) when they were caught by XMM-Newton. Most of the 13 sources are type I Seyfert galaxies. 5 of them are noticed to have strong X-ray variation for the first time. We study the nature of their variations through performing XMM-Newton spectral analyses and by collecting reports from the existing literature. We find the sample could be divided into three categories according to the possible causes of the strong X-ray variations. The variations in MRK 0478 and 1H 0419-557 are consistent with strong light-bending effect, i.e., the observed X-ray flux drops significantly as the X-ray emitting corona gets much closer to the central black hole. The variations in ESO 140-G043 and NGC 7158 are caused by absorption changes along the line of sight. For one special case MRK 0335, the variation can be explained by either light-bending or absorption variation. In the rest 8 sources (˜ 60%), the strong soft X-ray variations are likely to exist due to intrinsic changes in the activities of the corona, although in some of them without high quality X-ray spectra we are unable to rule out alternative models. This sample provides good targets for future monitoring campaigns with more extensive studies.

  20. Development of High Resolution X-Ray spectrometers for the Investigation of Bioinorganic Chemistry in Metalloproteins

    SciTech Connect

    Drury, Owen Byron

    2007-01-01

    Metals play as varied a role in biology as the proteins they are part of. They are involved in structure formation, they help transfer material and information, and they catalyze chemical reactions. Other proteins transport material or information, such as hemoglobin that distributes O2 and takes up CO2, or insulin that signals cells to increase glucose uptake in response to high blood glucose levels. Again other proteins promote chemical reactions, such as photosystem II responsible for photosynthetic oxygen evolution or nitrogenase which catalyzes the reduction of N2 to NH3. All of these proteins require the presence of a metal ion for their activity.

  1. Solar activity: The Sun as an X-ray star

    NASA Technical Reports Server (NTRS)

    Golub, L.

    1981-01-01

    The existence and constant activity of the Sun's outer atmosphere are thought to be due to the continual emergence of magnetic fields from the Solar interior and the stressing of these fields at or near the surface layers of the Sun. The structure and activity of the corona are thus symptomatic of the underlying magnetic dynamo and the existence of an outer turbulent convective zone on the Sun. A sufficient condition for the existence of coronal activity on other stars would be the existence of a magnetic dynamo and an outer convective zone. The theoretical relationship between magnetic fields and coronal activity can be tested by Solar observations, for which the individual loop structures can be resolved. A number of parameters however, which enter into the alternative theoretical formulations remain fixed in all Solar observations. To determine whether these are truly parameters of the theory observations need to be extended to nearby stars on which suitable conditions may occur.

  2. SOLAR POLAR X-RAY JETS AND MULTIPLE BRIGHT POINTS: EVIDENCE FOR SYMPATHETIC ACTIVITY

    SciTech Connect

    Pucci, Stefano; Romoli, Marco; Poletto, Giannina; Sterling, Alphonse C.

    2012-02-15

    We present an analysis of X-ray bright points (BPs) and X-ray jets observed by Hinode/X-Ray Telescope on 2007 November 2-4, within the solar northern polar coronal hole. After selecting small subregions that include several BPs, we followed their brightness evolution over a time interval of a few hours, when several jets were observed. We find that most of the jets occurred in close temporal association with brightness maxima in multiple BPs: more precisely, most jets are closely correlated with the brightening of at least two BPs. We suggest that the jets result from magnetic connectivity changes that also induce the BP variability. We surmise that the jets and implied magnetic connectivity we describe are small-scale versions of the active-region-scale phenomenon, whereby flares and eruptions are triggered by interacting bipoles.

  3. Electron-positron pairs, Compton reflection, and the X-ray spectra of active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Zdziarski, Andrzej A.; Ghisellini, Gabriele; George, Ian M.; Fabian, A. C.; Svensson, Roland; Done, Chris

    1990-01-01

    It is shown here that reprocessing of radiation fron nonthermal pair cascades by cold material in the central parts of active galactic nuclei (AGN) gives rise to X-ray and gamma-ray spectra that satisfy current observational constraints. An average 1-30 keV X-ray spectral index alpha(x) of about 0.7 in the compact range 30-300 is obtained for a wide range of Lorentz factors of the injected electrons. The gamma-ray spectra are steep, with alpha(gamma) about two, and satisfy the observational constraints. Radiation from pair cascades exhibits steep power law decreases in soft X-rays similar to those observed in AGN. The overall picture is consistent with AGN having an accretion disk which intercepts and reprocesses a substantial fraction of the nonthermal continuum incident upon it from above and below.

  4. THE EFFECTS OF X-RAY FEEDBACK FROM ACTIVE GALACTIC NUCLEI ON HOST GALAXY EVOLUTION

    SciTech Connect

    Hambrick, D. Clay; Ostriker, Jeremiah P.; Naab, Thorsten; Johansson, Peter H.

    2011-09-01

    Hydrodynamic simulations of galaxies with active galactic nuclei (AGNs) have typically employed feedback that is purely local, i.e., an injection of energy to the immediate neighborhood of the black hole (BH). We perform GADGET-2 simulations of massive elliptical galaxies with an additional feedback component: an observationally calibrated X-ray radiation field which emanates from the BH and heats gas out to large radii from the galaxy center. We find that including the heating and radiation pressure associated with this X-ray flux in our simulations enhances the effects which are commonly reported from AGN feedback. This new feedback model is twice as effective as traditional feedback at suppressing star formation, produces three times less star formation in the last 6 Gyr, and modestly lowers the final BH mass (30%). It is also significantly more effective than an X-ray background in reducing the number of satellite galaxies.

  5. On the origin of power-law X-ray spectra of active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Schlosman, I.; Shaham, J.; Shaviv, G.

    1984-01-01

    In the present analytical model for a power law X-ray continuum production in active galactic nuclei, the dissipation of turbulent energy flux above the accretion disk forms an optically thin transition layer with an inverted temperature gradient. The emitted thermal radiation has a power law spectrum in the 0.1-100 keV range, with a photon energy spectral index gamma of about 0.4-1.0. Thermal X-ray contribution from the layer is 5-10 percent of the total disk luminosity. The gamma value of 0.75 is suggested as a 'natural' power law index for Seyfert galaxies and QSOs.

  6. X-RAY FLUORESCENCE ANALYSIS OF HANFORD LOW ACTIVITY WASTE SIMULANTS METHOD DEVELOPMENT

    SciTech Connect

    Jurgensen, A; David Missimer, D; Ronny Rutherford, R

    2007-08-08

    The x-ray fluorescence laboratory (XRF) in the Analytical Development Directorate (ADD) of the Savannah River National Laboratory (SRNL) was requested to develop an x-ray fluorescence spectrometry method for elemental characterization of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) pretreated low activity waste (LAW) stream to the LAW Vitrification Plant. The WTP is evaluating the potential for using XRF as a rapid turnaround technique to support LAW product compliance and glass former batching. The overall objective of this task was to develop an XRF analytical method that provides rapid turnaround time (<8 hours), while providing sufficient accuracy and precision to determine variations in waste.

  7. Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection

    NASA Astrophysics Data System (ADS)

    LaMarr, Beverly; Bautz, Mark; Foster, Rick; Kissel, Steve; Prigozhin, Gregory; Suntharalingam, Vyshnavi

    2010-07-01

    MIT Lincoln Laboratories and MIT Kavli Institute for Astrophysics and Space Research have developed an active pixel sensor for use as a photon counting device for imaging spectroscopy in the soft X-ray band. A silicon-on-insulator (SOI) readout circuit was integrated with a high-resistivity silicon diode detector array using a per-pixel 3D integration technique developed at Lincoln Laboratory. We have tested these devices at 5.9 keV and 1.5 keV. Here we examine the interpixel cross-talk measured with 5.9 keV X-rays.

  8. The nuclear X-ray source in NGC 3628: A strange active galactic nucleus or the most luminous high-mass X-ray binary known?

    NASA Technical Reports Server (NTRS)

    Dahlem, Michael; Heckman, Timothy M.; Fabbiano, Giuseppina

    1995-01-01

    After 12 years, during which its unabsorbed soft X-ray flux in the 0.1-2.0 keV band was almost constant at about f(sub x) approximately 10(exp -12) ergs/s/sq cm, the compact nuclear source in NGC 3628 was not detected in one of our ROSAT observations, with a limiting sensitivity of f(sub x) approximately 5 x 10(exp -14) ergs/s/sq cm. Our data can be explained in two ways. The source is either the most massive X-ray binary known so far, with a greater than and approximately equal to 75 solar mass black hole, or an unusual low-luminosity Active Galactic Nuclei (AGN). The X-ray spectrum is typical of a high-mass X-ray binary, while the luminosity of the source of L(sub x) is approximately equal to 10(exp 40) ergs/s is more similar to those of low-luminosity AGNs. If it is an AGN, variable obscuration might explain the observed light curve.

  9. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

    SciTech Connect

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; and others

    2012-06-15

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  10. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline.

    PubMed

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Braillard, Aurélien; Hazemann, Jean-Louis; Prat, Alain; Testemale, Denis; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; Arnaud, Stéphan; Berar, Jean-François; Boudet, Nathalie; Caillot, Bernard; Chaurand, Perrine; Rose, Jérôme; Doelsch, Emmanuel; Martin, Philippe; Solari, Pier Lorenzo

    2012-06-01

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  11. Elliptically Bent X-ray Mirrors with Active Temperature Stabilization

    SciTech Connect

    Yuan, Sheng; Church, Matthew; Yashchuk, Valeriy V.; Goldberg, Kenneth A.; Celestre, Rich; McKinney, Wayne R.; Kirschman, Jonathan; Morrison, Greg; Noll, Tino; Warwick, Tony; Padmore, Howard A.

    2010-01-31

    We present details of design of elliptically bent Kirkpatrick-Baez mirrors developed and successfully used at the Advanced Light Source for submicron focusing. A distinctive feature of the mirror design is an active temperature stabilization based on a Peltier element attached directly to the mirror body. The design and materials have been carefully optimized to provide high heat conductance between the mirror body and substrate. We describe the experimental procedures used when assembling and precisely shaping the mirrors, with special attention paid to laboratory testing of the mirror-temperature stabilization. For this purpose, the temperature dependence of the surface slope profile of a specially fabricated test mirror placed inside a temperature-controlled container was measured. We demonstrate that with active mirror-temperature stabilization, a change of the surrounding temperature by more than 3K does not noticeably affect the mirror figure. Without temperature stabilization, the surface slope changes by approximately 1.5 ?mu rad rms (primarily defocus) under the same conditions.

  12. Miniature Neutron-Alpha Activation Spectrometer

    NASA Astrophysics Data System (ADS)

    Rhodes, Edgar; Holloway, James Paul; He, Zhong; Goldsten, John

    2002-10-01

    We are developing a miniature neutron-alpha activation spectrometer for in-situ analysis of chem-bio samples, including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform for Mars or outer-planet missions. In the neutron-activation mode, penetrating analysis will be performed of the whole sample using a γ spectrometer and in the α-activation mode, the sample surface will be analyzed using Rutherford-backscatter and x-ray spectrometers. Novel in our approach is the development of a switchable radioactive neutron source and a small high-resolution γ detector. The detectors and electronics will benefit from remote unattended operation capabilities resulting from our NEAR XGRS heritage and recent development of a Ge γ detector for MESSENGER. Much of the technology used in this instrument can be adapted to portable or unattended terrestrial applications for detection of explosives, chemical toxins, nuclear weapons, and contraband.

  13. The Discovery of X-ray Emission from Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Elvis, Martin

    2013-01-01

    Back in 1974 the UHURU catalog (3U) had been published with many UHGLS - unidentified high galactic latitude sources. Identifications were hampered by the square degree sized error boxes (positional uncertainties). Could these explain the cosmic X-ray background? Could UHGLS be "X-ray galaxies"? Only three active galaxies (AGNs) had been found as X-ray sources: 3C273, Cen A and NGC 4151, while others had upper limits. What was the difference between X-ray and non-X-ray AGNs? It turned out that the slightly better positioning capability and slightly deeper sensitivity of the Ariel V Sky Survey Instrument (SSI), launched in October 1974, were just enough to show that the UHGLS were Seyfert galaxies. And I was lucky enough that I'd joined the Leicester X-ray group and had taken on the UHGLS for my PhD thesis, with Ken Pounds as my supervisor. With the SSI we made a catalog of high latitude sources, the "2A" catalog, including about a dozen known Seyfert galaxies (lowish luminosity nearby AGNs) and, with Mike Penston and Martin Ward, we went on to identify many of them with both newly discovered normal broad emission line AGNs and a few new "narrow emission line galaxies", or NELGs, as we called them. We are now convinced that it is summation of many obscured NELGs that produce the flat spectrum of the X-ray background, and we are still searching for them in Chandra deep surveys and at higher energies with NuSTAR. There was an obvious connection between the X-ray obscuration and the optical reddening, which must lie outside the region emitting the broad optical spectral lines. Andy Lawrence and I, following a clue from Bill Keel, put this together into what we now call the Unified Scheme for AGN structure. This idea of a flattened torus obscuring the inner regions of the AGN was so dramatically confirmed a few years later -- by Ski Antonucci and Joe Miller's discovery of polarized broad emission lines in NGC1068 -- that the precursor papers became irrelevant. But Ariel

  14. Structural study of X-ray induced activation of carbonic anhydrase

    PubMed Central

    Sjöblom, Björn; Polentarutti, Maurizio; Djinović-Carugo, Kristina

    2009-01-01

    Carbonic anhydrase, a zinc metalloenzyme, catalyzes the reversible hydration of carbon dioxide to bicarbonate. It is involved in processes connected with acid–base homeostasis, respiration, and photosynthesis. More than 100 distinct human carbonic anhydrase II (HCAII) 3D structures have been generated in last 3 decades [Liljas A, et al. (1972) Nat New Biol 235:131–137], but a structure of an HCAII in complex with CO2 or HCO3− has remained elusive. Here, we report previously undescribed structures of HCAII:CO2 and HCAII:HCO3− complexes, together with a 3D molecular film of the enzymatic reaction observed successively in the same crystal after extended exposure to X-ray. We demonstrate that the unexpected enzyme activation was caused in an X-ray dose-dependent manner. Although X-ray damage to macromolecular samples has long been recognized [Ravelli RB, Garman EF (2006) Curr Opin Struct Biol 16:624–629], the detailed structural analysis reports on X-ray-driven reactions have been very rare in literature to date. Here, we report on enzyme activation and the associated chemical reaction in a crystal at 100 K. We propose mechanisms based on water photoradiolysis and/or electron radiolysis as the main cause of enzyme activation. PMID:19520834

  15. Structural study of X-ray induced activation of carbonic anhydrase.

    PubMed

    Sjöblom, Björn; Polentarutti, Maurizio; Djinovic-Carugo, Kristina

    2009-06-30

    Carbonic anhydrase, a zinc metalloenzyme, catalyzes the reversible hydration of carbon dioxide to bicarbonate. It is involved in processes connected with acid-base homeostasis, respiration, and photosynthesis. More than 100 distinct human carbonic anhydrase II (HCAII) 3D structures have been generated in last 3 decades [Liljas A, et al. (1972) Nat New Biol 235:131-137], but a structure of an HCAII in complex with CO(2) or HCO(3)(-) has remained elusive. Here, we report previously undescribed structures of HCAII:CO(2) and HCAII:HCO(3)(-) complexes, together with a 3D molecular film of the enzymatic reaction observed successively in the same crystal after extended exposure to X-ray. We demonstrate that the unexpected enzyme activation was caused in an X-ray dose-dependent manner. Although X-ray damage to macromolecular samples has long been recognized [Ravelli RB, Garman EF (2006) Curr Opin Struct Biol 16:624-629], the detailed structural analysis reports on X-ray-driven reactions have been very rare in literature to date. Here, we report on enzyme activation and the associated chemical reaction in a crystal at 100 K. We propose mechanisms based on water photoradiolysis and/or electron radiolysis as the main cause of enzyme activation. PMID:19520834

  16. Einstein Observatory SSS and MPC observations of the complex X-ray spectra of Seyfert galaxies. [Solid State Spectrometer and Monitor Proportional Counter

    NASA Technical Reports Server (NTRS)

    Turner, T. J.; Weaver, K. A.; Mushotzky, R. F.; Holt, S. S.; Madejski, G. M.

    1991-01-01

    The X-ray spectra of 25 Seyfert galaxies measured with the Solid State Spectrometer on the Einstein Observatory have been investigated. This new investigation utilizes simultaneous data from the Monitor Proportional Counter, and automatic correction for systematic effects in the Solid State Spectrometer which were previously handled subjectively. It is found that the best-fit single-power-law indices generally agree with those previously reported, but that soft excesses of some form are inferred for about 48 percent of the sources. One possible explanation of the soft excess emission is a blend of soft X-ray lines, centered around 0.8 keV. The implications of these results for accretion disk models are discussed.

  17. Development of a High Resolution X-Ray Imaging Crystal Spectrometer for Measurement of Ion-Temperature and Rotation-Velocity Profiles in Fusion Energy Research Plasmas

    SciTech Connect

    Hill, K W; Broennimann, Ch; Eikenberry, E F; Ince-Cushman, A; Lee, S G; Rice, J E; Scott, S

    2008-02-27

    A new imaging high resolution x-ray crystal spectrometer (XCS) has been developed to measure continuous profiles of ion temperature and rotation velocity in fusion plasmas. Following proof-of-principle tests on the Alcator C-Mod tokamak and the NSTX spherical tokamak, and successful testing of a new silicon, pixilated detector with 1MHz count rate capability per pixel, an imaging XCS is being designed to measure full profiles of Ti and vφ on C-Mod. The imaging XCS design has also been adopted for ITER. Ion-temperature uncertainty and minimum measurable rotation velocity are calculated for the C-Mod spectrometer. The affects of x-ray and nuclear-radiation background on the measurement uncertainties are calculated to predict performance on ITER.

  18. Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: identification of contributors to the background noise and shielding optimization.

    PubMed

    Thfoin, I; Reverdin, C; Hulin, S; Szabo, C I; Bastiani-Ceccotti, S; Batani, D; Brambrink, E; Koenig, M; Duval, A; Leboeuf, X; Lecherbourg, L; Rossé, B; Morace, A; Santos, J J; Vaisseau, X; Fourment, C; Giuffrida, L; Nakatsutsumi, M

    2014-11-01

    Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding. PMID:25430191

  19. Upgrades of poloidal and tangential x-ray imaging crystal spectrometers for temperature and rotation measurements on EAST

    NASA Astrophysics Data System (ADS)

    Wang, Fudi; Chen, Jun; Hu, Ruiji; Lyu, Bo; Colledani, Gilles; Fu, Jia; Li, Yingying; Bitter, Manfred; Hill, Kenneth; Lee, Sangon; Ye, Minyou; Shi, Yuejiang; Wan, Baonian

    2016-11-01

    During the past two years, key parts of poloidal and tangential x-ray imaging crystal spectrometers (PXCSs and TXCSs) have been upgraded. For poloidal XCSs, double-crystals of ArXVII and FeXXV were deployed. For fulfilling in situ alignment of a poloidal XCS, the beryllium window must be flexibly removed. By utilizing a design, where the beryllium window was installed in the vacuum chamber of the double-crystal, and between the double-crystal and wall of this chamber, an in situ alignment for the two spectrometers was fulfilled. Also, a new holder for the double-crystal was installed to allow for precise adjustments of azimuth angle and vertical height of the double-crystal. In order to facilitate these adjustments of double-crystal and installation of beryllium window, the chamber of the double-crystal for PXCS was upgraded from a cylinder to a cuboid. The distance between double-crystal and magnetic axis was extended from 8936 mm to 9850 mm in order to improve spatial resolution for PXCS, which is currently in the range from 1.237 mm to 4.80 mm at magnetic axis. Furthermore, a new pixelated detector (PILATUS 900K), which has a large sensitive area of 83.8 × 325.3 mm2 and which is vacuum compatible, is being implemented on the PXCS. This detector is mounted on a rail, so that its position can be changed by 50 mm to effectively record spectra of He-like argon and He-like iron (ArXVII and FeXXV). Similarly, a rail, which allows detector movement by 50 mm, was also installed in TXCS to alternatively record spectra of ArXVII and ArXVIII. Presently, the operation duration of PXCS and TXCS has been upgraded to hundreds of seconds in one shot. Ti- and uϕ-profiles measured by TXCS and charge exchange recombination spectroscopy (CXRS) were compared and found to be in good agreement.

  20. A new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolution

    SciTech Connect

    Bitter, M. Hill, K. W.; Efthimion, P. C.; Delgado-Aparicio, L.; Pablant, N.; Lu, Jian; Beiersdorfer, P.; Chen, Hui

    2014-11-15

    This paper describes a new type of x-ray crystal spectrometer, which can be used in combination with gated x-ray detectors to obtain spectra from laser-produced plasmas with a high (sub-ns) time resolution. The spectrometer consists of a convex, spherically bent crystal, which images individual spectral lines as perfectly straight lines across multiple, sequentially gated, strip detectors. Since the Bragg-reflected rays are divergent, the distance between detector and crystal is arbitrary, so that this distance can be appropriately chosen to optimize the experimental arrangement with respect to the detector parameters. The spectrometer concept was verified in proof-of-principle experiments by imaging the Lβ{sub 1}- and Lβ{sub 2}-lines of tungsten, at 9.6735 and 9.96150 keV, from a micro-focus x-ray tube with a tungsten target onto a two-dimensional pixilated Pilatus detector, using a convex, spherically bent Si-422 crystal with a radius of curvature of 500 mm.

  1. A new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolution.

    PubMed

    Bitter, M; Hill, K W; Efthimion, P C; Delgado-Aparicio, L; Pablant, N; Lu, Jian; Beiersdorfer, P; Chen, Hui

    2014-11-01

    This paper describes a new type of x-ray crystal spectrometer, which can be used in combination with gated x-ray detectors to obtain spectra from laser-produced plasmas with a high (sub-ns) time resolution. The spectrometer consists of a convex, spherically bent crystal, which images individual spectral lines as perfectly straight lines across multiple, sequentially gated, strip detectors. Since the Bragg-reflected rays are divergent, the distance between detector and crystal is arbitrary, so that this distance can be appropriately chosen to optimize the experimental arrangement with respect to the detector parameters. The spectrometer concept was verified in proof-of-principle experiments by imaging the Lβ1- and Lβ2-lines of tungsten, at 9.6735 and 9.96150 keV, from a micro-focus x-ray tube with a tungsten target onto a two-dimensional pixilated Pilatus detector, using a convex, spherically bent Si-422 crystal with a radius of curvature of 500 mm.

  2. Accretion disk winds in active galactic nuclei: X-ray observations, models, and feedback

    NASA Astrophysics Data System (ADS)

    Tombesi, F.

    2016-05-01

    Powerful winds driven by active galactic nuclei (AGN) are often invoked to play a fundamental role in the evolution of both supermassive black holes (SMBHs) and their host galaxies, quenching star formation and explaining the tight SMBH-galaxy relations. A strong support of this ``quasar mode'' feedback came from the recent X-ray observation of a mildly relativistic accretion disk wind in a ultraluminous infrared galaxy (ULIRG) and its connection with a large-scale molecular outflow, providing a direct link between the SMBH and the gas out of which stars form. Spectroscopic observations, especially in the X-ray band, show that such accretion disk winds may be common in local AGN and quasars. However, their origin and characteristics are still not fully understood. Detailed theoretical models and simulations focused on radiation, magnetohydrodynamic (MHD) or a combination of these two processes to investigate the possible acceleration mechanisms and the dynamics of these winds. Some of these models have been directly compared to X-ray spectra, providing important insights into the wind physics. However, fundamental improvements on these studies will come only from the unprecedented energy resolution and sensitivity of the upcoming X-ray observatories, namely ASTRO-H (launch date early 2016) and Athena (2028).

  3. A SEARCH FOR FAST X-RAY VARIABILITY FROM ACTIVE GALACTIC NUCLEI USING SWIFT

    SciTech Connect

    Pryal, Matthew; Falcone, Abe; Stroh, Michael

    2015-03-20

    Blazars are a class of active galactic nuclei (AGNs) known for their very rapid variabilty in the high energy regions of the electromagnetic spectrum. Despite this known fast variability, X-ray observations have generally not revealed variability in blazars with rate doubling or halving timescales less than approximately 15 minutes. Since its launch, the Swift X-ray Telescope has obtained 0.2–10 keV X-ray data on 143 AGNs, including blazars, through intense target of opportunity observations that can be analyzed in a multiwavelength context and used to model jet parameters, particularly during flare states. We have analyzed this broad Swift data set in a search for short timescale variability in blazars that could limit the size of the emission region in the blazar jet. While we do find several low-significance possible flares with potential indications of rapid variability, we find no strong evidence for rapid (<15 minutes) doubling or halving times in flares in the soft X-ray energy band for the AGNs analyzed.

  4. The First X-Ray Imaging Spectroscopy of Quiescent Solar Active Regions with NuSTAR

    NASA Astrophysics Data System (ADS)

    Hannah, Iain G.; Grefenstette, Brian W.; Smith, David M.; Glesener, Lindsay; Krucker, Säm; Hudson, Hugh S.; Madsen, Kristin K.; Marsh, Andrew; White, Stephen M.; Caspi, Amir; Shih, Albert Y.; Harrison, Fiona A.; Stern, Daniel; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; Hailey, Charles J.; Zhang, William W.

    2016-03-01

    We present the first observations of quiescent active regions (ARs) using the Nuclear Spectroscopic Telescope Array (NuSTAR), a focusing hard X-ray telescope capable of studying faint solar emission from high-temperature and non-thermal sources. We analyze the first directly imaged and spectrally resolved X-rays above 2 keV from non-flaring ARs, observed near the west limb on 2014 November 1. The NuSTAR X-ray images match bright features seen in extreme ultraviolet and soft X-rays. The NuSTAR imaging spectroscopy is consistent with isothermal emission of temperatures 3.1-4.4 MK and emission measures 1-8 × 1046 cm-3. We do not observe emission above 5 MK, but our short effective exposure times restrict the spectral dynamic range. With few counts above 6 keV, we can place constraints on the presence of an additional hotter component between 5 and 12 MK of ˜ {10}46 cm-3 and ˜ {10}43 cm-3, respectively, at least an order of magnitude stricter than previous limits. With longer duration observations and a weakening solar cycle (resulting in an increased livetime), future NuSTAR observations will have sensitivity to a wider range of temperatures as well as possible non-thermal emission.

  5. A comparison of photospheric electric current and ultraviolet and X-ray emission in a solar active region

    NASA Technical Reports Server (NTRS)

    Haisch, B. M.; Bruner, M. E.; Hagyard, M. J.; Bonnet, R. M.

    1986-01-01

    This paper presents an extensive set of coordinated observations of a solar active region, taking into account spectroheliograms obtained with the aid of the Solar Maximum Mission (SMM) Ultraviolet Spectrometer Polarimeter (UVSP) instrument, SMM soft X-ray polychromator (XRP) raster maps, and high spatial resolution ultraviolet images of the sun in Lyman-alpha and in the 1600 A continuum. These data span together the upper solar atmosphere from the temperature minimum to the corona. The data are compared to maps of the inferred photospheric electric current derived from the Marshall Space Flight Center (MSFC) vector magnetograph observations. Some empirical correlation is found between regions of inferred electric current density and the brightest features in the ultraviolet continuum and to a lesser extent those seen in Lyman-alpha within an active region.

  6. Resonant inelastic X-ray scattering spectrometer with 25meV resolution at the Cu K -edge

    SciTech Connect

    Ketenoglu, Didem; Harder, Manuel; Klementiev, Konstantin; Upton, Mary; Taherkhani, Mehran; Spiwek, Manfred; Dill, Frank-Uwe; Wille, Hans-Christian; Yavaş, Hasan

    2015-06-27

    An unparalleled resolution is reported with an inelastic X-ray scattering instrument at the CuK-edge. Based on a segmented concave analyzer, featuring single-crystal quartz (SiO2) pixels, the spectrometer delivers a resolution near 25meV (FWHM) at 8981eV. Besides the quartz analyzer, the performance of the spectrometer relies on a four-bounce Si(553) high-resolution monochromator and focusing Kirkpatrick–Baez optics. The measured resolution agrees with the ray-tracing simulation of an ideal spectrometer. The performance of the spectrometer is demonstrated by reproducing the phonon dispersion curve of a beryllium single-crystal.

  7. ACTIVE GALAXY UNIFICATION IN THE ERA OF X-RAY POLARIMETRY

    SciTech Connect

    Dorodnitsyn, A.; Kallman, T.

    2010-03-10

    Active galactic nuclei (AGNs), Seyfert galaxies, and quasars are powered by luminous accretion and often accompanied by winds that are powerful enough to affect the AGN mass budget, and whose observational appearance bears an imprint of processes that are happening within the central parsec around the black hole (BH). One example of such a wind is the partially ionized gas responsible for X-ray and UV absorption (warm absorbers). Here, we show that such gas will have a distinct signature when viewed in polarized X-rays. Observations of such polarization can test models for the geometry of the flow and the gas responsible for launching and collimating it. We present calculations that show that the polarization depends on the hydrodynamics of the flow, the quantum mechanics of resonance-line scattering, and the transfer of polarized X-ray light in the highly ionized moving gas. The results emphasize the three-dimensional nature of the wind for modeling spectra. We show that the polarization in the 0.1-10 keV energy range is dominated by the effects of resonance lines. We predict a 5%-25% X-ray polarization signature of type-2 objects in this energy range. These results are generalized to flows that originate from a cold torus-like structure, located {approx}1 pc from the BH, which wraps the BH and is ultimately responsible for the apparent dichotomy between type 1 and type 2 AGNs. Such signals will be detectable by future dedicated X-ray polarimetry space missions, such as the NASA Gravity and Extreme Magnetism Small Explorer.

  8. X-Ray Flaring Activity of MRK 421 in the First Half of 2013

    NASA Astrophysics Data System (ADS)

    Kapanadze, B.; Dorner, D.; Vercellone, S.; Romano, P.; Aller, H.; Aller, M.; Hughes, P.; Reynolds, M.; Kapanadze, S.; Tabagari, L.

    2016-11-01

    We present the results of the Swift and NuSTAR observations of the nearby BL Lac object Mrk 421 during 2013 January–June. The source exhibited a strong long-term variability in the 0.3–10 keV and 3–79 keV bands with the maximum-to-minimum daily-binned flux ratios of 22 and 95, respectively, in about 3 months, mainly due to unprecedented strong X-ray outbursts by more than an order of magnitude in both bands within 2 weeks in 2013 April when the 0.3–10 keV count rate exceeded the level of 200 cts s‑1 for the first time, and Mrk 421 became one of the brightest sources in the X-ray sky. The source was also very active on intra-day timescales, and it showed flux doubling and halving timescales of 1.16–7.20 hr and 1.04–3.54 hr, respectively. On some occasions, the flux varied by 4%–23% within 300–840 s. During this period, the source also exhibited some of the most extreme X-ray spectral variability ever reported for BL Lacs—the location of the synchrotron spectral energy distribution peak shifted from a few eV to ∼10 keV, and the photon index at 1 keV and curvature parameter varied on timescales from a few weeks down to intervals shorter than 1 ks. MAGIC and First G-APD Cherenkov Telescope observations also revealed a very strong very high energy (VHE) flare during April 11–17. The UV and HE γ-ray flares were much weaker compared to their X-ray counterparts, and they generally showed significantly stronger correlation with each other than with the X-ray fluxes.

  9. Ionized Absorbers in Active Galactic Nuclei and Very Steap Soft X-Ray Quasars

    NASA Technical Reports Server (NTRS)

    Fiore, Fabrizio; White, Nicholas (Technical Monitor)

    2000-01-01

    Steep soft X-ray (0.1-2 keV) quasars share several unusual properties: narrow Balmer lines, strong Fe II emission, large and fast X-ray variability, and a rather steep 2-10 keV spectrum. These intriguing objects have been suggested to be the analogues of Galactic black hole candidates in the high, soft state. We present here results from ASCA observations for two of these quasars: NAB 0205 + 024 and PG 1244 + 026. Both objects show similar variations (factor of approximately 2 in 10 ks), despite a factor of approximately 10 difference in the 0.5-10 keV luminosity (7.3 x 10(exp 43) erg/s for PG 1244 + 026 and 6.4 x 10(exp 44) erg/s for NAB 0205 + 024, assuming isotropic emission, H(sub 0) = 50.0 and q(sub 0) = 0.0). The X-ray continuum of the two quasars flattens by 0.5-1 going from the 0.1-2 keV band towards higher energies, strengthening recent results on another half-dozen steep soft X-ray active galactic nuclei. PG 1244 + 026 shows a significant feature in the '1-keV' region, which can be described either as a broad emission line centered at 0.95 keV (quasar frame) or as edge or line absorption at 1.17 (1.22) keV. The line emission could be a result of reflection from a highly ionized accretion disc, in line with the view that steep soft X-ray quasars are emitting close to the Eddington luminosity. Photoelectric edge absorption or resonant line absorption could be produced by gas outflowing at a large velocity (0.3-0.6 c).

  10. A CANDIDATE ACTIVE GALACTIC NUCLEUS WITH A PURE SOFT THERMAL X-RAY SPECTRUM

    SciTech Connect

    Terashima, Yuichi; Kamizasa, Naoya; Awaki, Hisamitsu; Kubota, Aya; Ueda, Yoshihiro

    2012-06-20

    We report the discovery of a candidate active galactic nucleus (AGN), 2XMM J123103.2+110648 at z = 0.13, with an X-ray spectrum represented purely by soft thermal emission reminiscent of Galactic black hole (BH) binaries in the disk-dominated state. This object was found in the second XMM-Newton serendipitous source catalog as a highly variable X-ray source. In three separate observations, its X-ray spectrum can be represented either by a multicolor disk blackbody model with an inner temperature of kT{sub in} Almost-Equal-To 0.16-0.21 keV or a Wien spectrum Comptonized by an optically thick plasma with kT Almost-Equal-To 0.14-0.18 keV. The soft X-ray luminosity in the 0.5-2 keV band is estimated to be (1.6-3.8) Multiplication-Sign 10{sup 42} erg s{sup -1}. Hard emission above {approx}2 keV is not detected. The ratio of the soft to hard emission is the strongest among AGNs observed thus far. Spectra selected in high/low-flux time intervals are examined in order to study spectral variability. In the second observation with the highest signal-to-noise ratio, the low-energy (below 0.7 keV) spectral regime flattens when the flux is high, while the shape of the high-energy part (1-1.7 keV) remains unchanged. This behavior is qualitatively consistent with being caused by strong Comptonization. Both the strong soft excess and spectral change consistent with Comptonization in the X-ray spectrum imply that the Eddington ratio is large, which requires a small BH mass (smaller than {approx}10{sup 5} M{sub Sun }).

  11. OZSPEC-2: An improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited)

    SciTech Connect

    Heeter, R. F.; Anderson, S. G.; Booth, R.; Brown, G. V.; Emig, J.; Fulkerson, S.; McCarville, T.; Norman, D.; Schneider, M. B.; Young, B. K. F.

    2008-10-15

    A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270-650, 660-1580, and 1960-4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments' single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100x35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30-50 {mu}m resolution over a 1500 {mu}m field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/{delta}E>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.

  12. ROSAT x ray survey observations of active chromospheric binary systems and other selected sources

    NASA Technical Reports Server (NTRS)

    Ramsey, Lawrence W.

    1993-01-01

    The connection between processes that produce optical chromospheric activity indicators and those that produce x-rays in RS CVn binary systems by taking advantage of the ROSAT All-Sky Survey (RASS) results and our unique ground-based data set was investigated. In RS CVn systems, excess emission in the Ca 2 resonance (K & H) and infrared triplet (IRT) lines and in the Balmer lines of hydrogen is generally cited as evidence for chromospheric activity, which is usually modeled as scaled up solar-type activity. X-ray emission in RS CVn systems is believed to arise from coronal loop structures. Results from spectra data obtained from RASS observations are discussed and presented.

  13. X-ray imaging of chemically active valence electrons during a pericyclic reaction.

    PubMed

    Bredtmann, Timm; Ivanov, Misha; Dixit, Gopal

    2014-11-26

    Time-resolved imaging of chemically active valence electron densities is a long-sought goal, as these electrons dictate the course of chemical reactions. However, X-ray scattering is always dominated by the core and inert valence electrons, making time-resolved X-ray imaging of chemically active valence electron densities extremely challenging. Here we demonstrate an effective and robust method, which emphasizes the information encoded in weakly scattered photons, to image chemically active valence electron densities. The degenerate Cope rearrangement of semibullvalene, a pericyclic reaction, is used as an example to visually illustrate our approach. Our work also provides experimental access to the long-standing problem of synchronous versus asynchronous bond formation and breaking during pericyclic reactions.

  14. X-ray imaging of chemically active valence electrons during a pericyclic reaction

    PubMed Central

    Bredtmann, Timm; Ivanov, Misha; Dixit, Gopal

    2014-01-01

    Time-resolved imaging of chemically active valence electron densities is a long-sought goal, as these electrons dictate the course of chemical reactions. However, X-ray scattering is always dominated by the core and inert valence electrons, making time-resolved X-ray imaging of chemically active valence electron densities extremely challenging. Here we demonstrate an effective and robust method, which emphasizes the information encoded in weakly scattered photons, to image chemically active valence electron densities. The degenerate Cope rearrangement of semibullvalene, a pericyclic reaction, is used as an example to visually illustrate our approach. Our work also provides experimental access to the long-standing problem of synchronous versus asynchronous bond formation and breaking during pericyclic reactions. PMID:25424639

  15. The Distribution of Magnesium on Mercury’s Surface as Measured by the MESSENGER X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Nittler, Larry R.; Weider, S. Z.; Starr, R. D.; Crapster-Pregont, E. J.; Byrne, P. K.; Denevi, B. W.; Blewett, D. T.; Solomon, S. C.

    2013-10-01

    We have used >6000 individual measurements acquired over two years by MESSENGER’s X-Ray Spectrometer (XRS) to construct a global map of the Mg/Si ratio across Mercury’s surface. In the northern hemisphere, both spatial coverage and resolution are sufficient to compare our map with geologic features. The global Mg/Si ratio varies from 0.15 to 0.90, which we attribute mainly to variations in Mg given that MESSENGER gamma-ray measurements indicate little variation in Si. Our work supports earlier results showing that large expanses of volcanic smooth plains at northern latitudes and in the interior of the Caloris basin have relatively uniform and low Mg/Si. In contrast, older intercrater plains and heavily cratered terrain (IcP-HCT) show striking variability in Mg/Si. The highest Mg/Si ratios (> 0.7) are seen in low-reflectance ejecta deposits that surround the Rachmaninoff impact basin, and in a large (>5×106 km2), relatively homogeneous region that is centered at ~30°N, 290°E. This region also has the lowest Al and highest Ca and S abundances derived from XRS data. Comparison with a map of crustal thickness (derived from MESSENGER geophysical data) shows that the large Mg-rich region coincides with an area of relatively thin crust. The shared boundaries (between high and low Mg, and between thick and thin crust) are particularly sharp along the northern and eastern edges; the latter is also near a major north-south-oriented fold-and-thrust belt and a region with a high density of observed hollows. There may also be a correlation between the Mg content and age of Mercury’s surface. The large Mg-rich region overlaps partly with some of Mercury’s oldest terrain as inferred from crater densities. Younger parts of the IcP-HCT (e.g., around Amaral crater) have significantly lower Mg/Si than the planetary average. Mercury’s surface is likely to have been extensively resurfaced by volcanism early in the planet’s history, so Mg/Si variations within regions of

  16. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    PubMed

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that

  17. Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

    PubMed

    Laohaudomchok, Wisanti; Cavallari, Jennifer M; Fang, Shona C; Lin, Xihong; Herrick, Robert F; Christiani, David C; Weisskopf, Marc G

    2010-08-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM(2.5) deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman rho = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that

  18. Assessment of Occupational Exposure to Manganese and Other Metals in Welding Fumes by Portable X-ray Fluorescence Spectrometer

    PubMed Central

    Laohaudomchok, Wisanti; Cavallari, Jennifer M.; Fang, Shona C.; Lin, Xihong; Herrick, Robert F.; Christiani, David C.; Weisskopf, Marc G.

    2011-01-01

    Elemental analysis of welding fume samples can be done using several laboratory-based techniques. However, portable measurement techniques could offer several advantages. In this study, we sought to determine whether the portable X-ray fluorescence spectrometer (XRF) is suitable for analysis of five metals (manganese, iron, zinc, copper, and chromium) on 37-mm polytetrafluoroethylene filters. Using this filter fitted on a cyclone in line with a personal pump, gravimetric samples were collected from a group of boilermakers exposed to welding fumes. We assessed the assumption of uniform deposition of these metals on the filters, and the relationships between measurement results of each metal obtained from traditional laboratory-based XRF and the portable XRF. For all five metals of interest, repeated measurements with the portable XRF at the same filter area showed good consistency (reliability ratios are equal or close to 1.0 for almost all metals). The portable XRF readings taken from three different areas of each filter were not significantly different (p-values = 0.77 to 0.98). This suggested that the metal rich PM2.5 deposits uniformly on the samples collected using this gravimetric method. For comparison of the two XRFs, the results from the portable XRF were well correlated and highly predictive of those from the laboratory XRF. The Spearman correlation coefficients were from 0.325 for chromium, to 0.995 for manganese and 0.998 for iron. The mean differences as a percent of the mean laboratory XRF readings were also small (<5%) for manganese, iron, and copper. The differences were greater for zinc and chromium, which were present at very low amounts in our samples and below the limits of detection of the portable XRF for many of the samples. These five metals were moderately to strongly correlated with the total fine particle fraction on filters (Spearman ρ = 0.41 for zinc to 0.97 for iron). Such strong correlations and comparable results suggested that the

  19. X-ray excited ZnS:Cu,Co afterglow nanoparticles for photodynamic activation

    NASA Astrophysics Data System (ADS)

    Ma, Lun; Zou, Xiaoju; Bui, Brian; Chen, Wei; Song, Kwang Hyun; Solberg, Timothy

    2014-07-01

    Copper and cobalt co-doped ZnS (ZnS:Cu,Co) afterglow nanoparticles were conjugated to photosensitizer tetrabromorhodamine-123 (TBrRh123) and efficient energy transfer from the nanoparticles to TBrRh123 was observed. In addition to their X-ray excited luminescence, the ZnS:Cu,Co nanoparticles also show long lasting afterglow, which continuously serve as a light source for photodynamic therapy (PDT) activation. Compared to TBrRh123 or ZnS:Cu,Co alone, the ZnS:Cu,Co-TBrRh123 conjugates show low dark toxicity but high X-ray induced toxicity to human prostate cancer cells. The results indicate that the ZnS:Cu,Co afterglow nanoparticles have a good potential for PDT activation.

  20. X-ray crystal spectrometer for opacity measurements in the 8-18 A spectral range at the LULI laser facility

    SciTech Connect

    Reverdin, C.; Thais, F.; Loisel, G.; Bougeard, M.

    2010-10-15

    An x-ray crystal spectrometer was built in order to measure opacities in the 8-18 A spectral range with an average spectral resolution of <{lambda}/{delta}{lambda}>{approx}400. It has been successfully used at the LULI-2000 laser facility (See C. Sauteret, rapport LULI 2001, 88 (2002) at Ecole Polytechnique (France) to measure in the same experimental conditions the 2p-3d transitions of several elements with the neighboring atomic number Z: Fe, Ni, Cu, and Ge [G. Loisel et al., High Energy Density Phys. 5, 173 (2009)]. Hence, a spectrometer with a wide spectral range is needed. This spectrometer features two lines of sight. In this example, one line of sight looks through the sample and the other one is looking directly at the backlighter emission. Both are outfitted with a spherical condensing mirror. A TlAP crystal is used for spectral dispersion. Detection is made with an image plate Fuji BAS TR2025, which is sensitive to x rays. We present some experimental results showing the performances of this spectrometer.

  1. X-ray crystal spectrometer for opacity measurements in the 8-18 Å spectral range at the LULI laser facilitya)

    NASA Astrophysics Data System (ADS)

    Reverdin, C.; Thais, F.; Loisel, G.; Bougeard, M.

    2010-10-01

    An x-ray crystal spectrometer was built in order to measure opacities in the 8-18 Å spectral range with an average spectral resolution of ⟨λ /δλ⟩˜400. It has been successfully used at the LULI-2000 laser facility (See C. Sauteret, rapport LULI 2001, 88 (2002) at École Polytechnique (France) to measure in the same experimental conditions the 2p-3d transitions of several elements with the neighboring atomic number Z: Fe, Ni, Cu, and Ge [G. Loisel et al., High Energy Density Phys. 5, 173 (2009)]. Hence, a spectrometer with a wide spectral range is needed. This spectrometer features two lines of sight. In this example, one line of sight looks through the sample and the other one is looking directly at the backlighter emission. Both are outfitted with a spherical condensing mirror. A TlAP crystal is used for spectral dispersion. Detection is made with an image plate Fuji BAS TR2025, which is sensitive to x rays. We present some experimental results showing the performances of this spectrometer.

  2. X-ray crystal spectrometer for opacity measurements in the 8-18 Å spectral range at the LULI laser facility.

    PubMed

    Reverdin, C; Thais, F; Loisel, G; Bougeard, M

    2010-10-01

    An x-ray crystal spectrometer was built in order to measure opacities in the 8-18 Å spectral range with an average spectral resolution of <λ/δλ> ∼ 400. It has been successfully used at the LULI-2000 laser facility (See C. Sauteret, rapport LULI 2001, 88 (2002) at École Polytechnique (France) to measure in the same experimental conditions the 2p-3d transitions of several elements with the neighboring atomic number Z: Fe, Ni, Cu, and Ge [G. Loisel et al., High Energy Density Phys. 5, 173 (2009)]. Hence, a spectrometer with a wide spectral range is needed. This spectrometer features two lines of sight. In this example, one line of sight looks through the sample and the other one is looking directly at the backlighter emission. Both are outfitted with a spherical condensing mirror. A TlAP crystal is used for spectral dispersion. Detection is made with an image plate Fuji BAS TR2025, which is sensitive to x rays. We present some experimental results showing the performances of this spectrometer. PMID:21034025

  3. The Spectrometer/Telescope for Imaging X-rays on Solar Orbiter: Flight design, challenges and trade-offs

    NASA Astrophysics Data System (ADS)

    Krucker, S.; Bednarzik, M.; Grimm, O.; Hurford, G. J.; Limousin, O.; Meuris, A.; Orleański, P.; Seweryn, K.; Skup, K. R.

    2016-07-01

    STIX is the X-ray spectral imaging instrument on-board the Solar Orbiter space mission of the European Space Agency, and together with nine other instruments will address questions of the interaction between the Sun and the heliosphere. STIX will study the properties of thermal and accelerated electrons near the Sun through their Bremsstrahlung X-ray emission, addressing in particular the emission from flaring regions on the Sun. The design phase of STIX has been concluded. This paper reports the final flight design of the instrument, focusing on design challenges that were faced recently and how they were addressed.

  4. Global Mg/Si and Al/Si Distributions on the Lunar Surface Derived from Chang'E-2 X-ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Dong, Wu-Dong; Zhang, Xiao-Ping; Zhu, Meng-Hua; Xu, Ao-Ao; Tang, Ze-Sheng

    2016-01-01

    The technique of X-ray fluorescence remote sensing plays a significant role in research related to the chemical compositions of the Moon. Here we describe the data analysis method for China's Chang'E-2 X-ray spectrometer in detail and present the preliminary results about the first global Mg/Si and Al/Si maps of the lunar surface. Our results show that the distributions of Mg/Si and Al/Si correlate well with terrains on the Moon. The higher Mg/Si ratio corresponds to the mare regions while the lower value corresponds to the highland terrains. The map of the Al/Si ratio shows a reversed distribution compared with the map of the Mg/Si ratio.

  5. Observations of celestial X-ray sources above 20 keV with the high-energy scintillation spectrometer on board OSO 8

    NASA Technical Reports Server (NTRS)

    Crannell, C. J.; Dennis, B. R.; Dolan, J. H.; Frost, K. J.; Orwig, L. E.; Beall, J. H.; Maurer, G. S.

    1977-01-01

    High-energy X-ray spectra of the Crab Nebula, Cyg- XR-1, and Cen A were determined from observations with the scintillation spectrometer on board the OSO-8 satellite, launched in June, 1975. Each of these sources was observed over two periods of 8 days or more, enabling a search for day-to-day and year to year variations in the spectral and temporal characteristics of the X-ray emission. No variation in the light curve of the Crab pulsar was found from observations which span a 15-day period in March 1976, with demonstrable phase stability. Transitions associated with the binary phase of Cyg XR-1 and a large change in the emission from Con A are reported.

  6. Reconstruction of the energy spectrum of electrons accelerated in the April 15, 2002 solar flare based on IRIS X-ray spectrometer measurements

    NASA Astrophysics Data System (ADS)

    Motorina, G. G.; Kudryavtsev, I. V.; Lazutkov, V. P.; Savchenko, M. I.; Skorodumov, D. V.; Charikov, Yu. E.

    2016-04-01

    We reconstruct the energy distribution of electrons accelerated in the April 15, 2002 solar flare on the basis of the data from the IRIS X-ray spectrometer onboard the CORONAS-F satellite. We obtain the solution to the integral equations describing the transformation of the spectrum of X-ray photons during the recording and reconstruction of the spectrum of accelerated electrons in the bremsstrahlung source using the random search method and the Tikhonov regularization method. In this event, we detected a singularity in the electron spectrum associated with the existence of a local minimum in the energy range 40-60 keV, which cannot be detected by a direct method.

  7. Piecing together the X-ray background: bolometric corrections for active galactic nuclei

    NASA Astrophysics Data System (ADS)

    Vasudevan, R. V.; Fabian, A. C.

    2007-11-01

    The X-ray background can be used to constrain the accretion history of supermassive black holes (SMBHs) in active galactic nuclei (AGN), with the SMBH mass density related to the energy density due to accretion. A knowledge of the hard X-ray bolometric correction, κ2-10keV, is a vital input into these studies, as it allows us to constrain the parameters of the accretion responsible for SMBH growth. Earlier studies assumed a constant bolometric correction for all AGN, and more recent work has suggested accounting for a dependence on AGN luminosity. Until recently, the variations in the disc emission in the ultraviolet (UV) have not been taken into account in this calculation; we show that such variations are important by construction of optical-to-X-ray spectral energy distributions for 54 AGN. In particular, we use Far Ultraviolet Spectroscopic Explorer (FUSE) UV and X-ray data from the literature to constrain the disc emission as well as possible. We find evidence for very significant spread in the bolometric corrections, with no simple dependence on luminosity being evident. Populations of AGN such as narrow-line Seyfert 1 nuclei, radio-loud and X-ray-weak AGN may have bolometric corrections which differ systematically from the rest of the AGN population. We identify other sources of uncertainty including intrinsic extinction in the optical-UV, X-ray and UV variability and uncertainties in SMBH mass estimates. Our results suggest a more well-defined relationship between the bolometric correction and Eddington ratio in AGN, with a transitional region at an Eddington ratio of ~0.1, below which the bolometric correction is typically 15-25, and above which it is typically 40-70. We consider the potential-implied parallels with the low/hard and high/soft states in Galactic black hole (GBH) accretion, and present bolometric corrections for the GBH binary GX 339-4 for comparison. Our findings reinforce previous studies proposing a multistate description of AGN

  8. Ensemble X-ray variability of active galactic nuclei. II. Excess variance and updated structure function

    NASA Astrophysics Data System (ADS)

    Vagnetti, F.; Middei, R.; Antonucci, M.; Paolillo, M.; Serafinelli, R.

    2016-09-01

    Context. Most investigations of the X-ray variability of active galactic nuclei (AGN) have been concentrated on the detailed analyses of individual, nearby sources. A relatively small number of studies have treated the ensemble behaviour of the more general AGN population in wider regions of the luminosity-redshift plane. Aims: We want to determine the ensemble variability properties of a rich AGN sample, called Multi-Epoch XMM Serendipitous AGN Sample (MEXSAS), extracted from the fifth release of the XMM-Newton Serendipitous Source Catalogue (XMMSSC-DR5), with redshift between ~0.1 and ~5, and X-ray luminosities in the 0.5-4.5 keV band between ~1042 erg/s and ~1047 erg/s. Methods: We urge caution on the use of the normalised excess variance (NXS), noting that it may lead to underestimate variability if used improperly. We use the structure function (SF), updating our previous analysis for a smaller sample. We propose a correction to the NXS variability estimator, taking account of the light curve duration in the rest frame on the basis of the knowledge of the variability behaviour gained by SF studies. Results: We find an ensemble increase of the X-ray variability with the rest-frame time lag τ, given by SF ∝ τ0.12. We confirm an inverse dependence on the X-ray luminosity, approximately as SF ∝ LX-0.19. We analyse the SF in different X-ray bands, finding a dependence of the variability on the frequency as SF ∝ ν-0.15, corresponding to a so-called softer when brighter trend. In turn, this dependence allows us to parametrically correct the variability estimated in observer-frame bands to that in the rest frame, resulting in a moderate (≲15%) shift upwards (V-correction). Conclusions: Ensemble X-ray variability of AGNs is best described by the structure function. An improper use of the normalised excess variance may lead to an underestimate of the intrinsic variability, so that appropriate corrections to the data or the models must be applied to prevent

  9. Investigation of Water-Soluble X-ray Luminescence Nanoparticles for Photodynamic Activation

    SciTech Connect

    Liu, Yuanfang; Chen, Wei; Wang, Shaopeng; Joly, Alan G.

    2008-01-28

    In this letter, we report the synthesis of LaF3:Tb3+-MTCP (meso-Tetra(4-carboxyphenyl) porphine) nanoparticle conjugates and investigate the energy transfer as well as singlet oxygen generation following X-ray irradiation. Our observations indicate that LaF3:Tb3+-MTCP nanoparticle conjugates are efficient photodynamic agents that can be initiated by X-rays at a reasonably low dose. The addition of folic acid to facilitate targeting to folate receptors on tumor cells has no effect on the quantum yield of singlet oxygen in the nanoparticle-MTCP conjugates. Our pilot studies indicate that water-soluble scintillation nanoparticles can be potentially used to activate photodynamic therapy as a promising deep cancer treatment.

  10. Manufacturing an active X-ray mirror prototype in thin glass.

    PubMed

    Spiga, D; Barbera, M; Collura, A; Basso, S; Candia, R; Civitani, M; Di Bella, M S; Di Cicca, G; Lo Cicero, U; Lullo, G; Pelliciari, C; Riva, M; Salmaso, B; Sciortino, L; Varisco, S

    2016-01-01

    Adjustable mirrors equipped with piezo actuators are commonly used at synchrotron and free-electron laser (FEL) beamlines, in order to optimize their focusing properties and sometimes to shape the intensity distribution of the focal spot with the desired profile. Unlike them, X-ray mirrors for astronomy are much thinner in order to enable nesting and reduce the areal mass, and the application of piezo actuators acting normally to the surface appears much more difficult. There remains the possibility to correct the deformations using thin patches that exert a tangential strain on the rear side of the mirror: some research groups are already at work on this approach. The technique reported here relies on actively integrating thin glass foils with commercial piezoceramic patches, fed by voltages driven by the feedback provided by X-rays, while the tension signals are carried by electrodes on the back of the mirror, obtained by photolithography. Finally, the shape detection and the consequent voltage signal to be provided to the piezoelectric array will be determined by X-ray illumination in an intra-focal setup at the XACT facility. In this work, the manufacturing steps for obtaining a first active mirror prototype are described. PMID:26698046

  11. Manufacturing an active X-ray mirror prototype in thin glass.

    PubMed

    Spiga, D; Barbera, M; Collura, A; Basso, S; Candia, R; Civitani, M; Di Bella, M S; Di Cicca, G; Lo Cicero, U; Lullo, G; Pelliciari, C; Riva, M; Salmaso, B; Sciortino, L; Varisco, S

    2016-01-01

    Adjustable mirrors equipped with piezo actuators are commonly used at synchrotron and free-electron laser (FEL) beamlines, in order to optimize their focusing properties and sometimes to shape the intensity distribution of the focal spot with the desired profile. Unlike them, X-ray mirrors for astronomy are much thinner in order to enable nesting and reduce the areal mass, and the application of piezo actuators acting normally to the surface appears much more difficult. There remains the possibility to correct the deformations using thin patches that exert a tangential strain on the rear side of the mirror: some research groups are already at work on this approach. The technique reported here relies on actively integrating thin glass foils with commercial piezoceramic patches, fed by voltages driven by the feedback provided by X-rays, while the tension signals are carried by electrodes on the back of the mirror, obtained by photolithography. Finally, the shape detection and the consequent voltage signal to be provided to the piezoelectric array will be determined by X-ray illumination in an intra-focal setup at the XACT facility. In this work, the manufacturing steps for obtaining a first active mirror prototype are described.

  12. The fabrication and characterisation of piezoelectric actuators for active x-ray optics

    NASA Astrophysics Data System (ADS)

    Zhang, Dou; Rodriguez Sanmartin, Daniel; Button, Tim W.; Meggs, Carl; Atkins, Carolyn; Doel, Peter; Brooks, David; Feldman, Charlotte; Willingale, Richard; Michette, Alan; Pfauntsch, Slawka; Sahraei, Shahin; James, Ady; Dunare, Camelia; Stevenson, Tom; Parkes, William; Smith, Andrew; Wang, Hongchang

    2009-08-01

    Piezoelectric actuators are widely employed in adaptive optics to enable an actively controlled mirror surface and improve the optical resolution and sensitivity. Currently two new prototype adaptive X-ray optical systems are under development through the Smart X-ray Optics project in a UK based consortium. One proposed technology is micro-structured optical arrays (MOAs) which uses aligned micro-channels structures obtained by deep silicon etching using both dry and wet techniques and bonded piezoelectric actuators to produce a micro-focused X-ray source for biological applications. The other technology is large scale optics which uses a thin shell mirror segment with 20-40 bonded piezo-actuators for the next generation of X-ray telescopes with an aim to achieve a resolution greater than that currently available by Chandra (0.5"). The Functional Materials Group of Birmingham University has the capability of fabricating a wide range of piezo-actuators including, for example, unimorph, bimorph and active fibre composites (AFC) by using a viscous plastic processing technique. This offers flexibility in customising the shapes (from planar to 3-D helix) and feature sizes (>20 μm) of the actuators, as well as achieving good piezoelectric properties. PZT unimorph actuators are being developed in this programme according to the design and implementation of the proposed mirror and array structures. Precise controls on the dimension, thickness, surface finishing and the curvature have been achieved for delivering satisfactory actuators. Results are presented regarding the fabrication and characterisation of such piezo-actuators, as well as the progress on the large optic and MOAs prototypes employing the piezo-actuators.

  13. The dependence of X-ray AGN activity on host galaxy properties and environment

    NASA Astrophysics Data System (ADS)

    Tasse, C.; Röttgering, H.; Best, P. N.

    2011-01-01

    There is mounting evidence that active galactic nuclei (AGN) selected through optical emission lines or radio luminosities comprise two distinct AGN populations, whose activity is triggered by different processes. In two previous papers, we studied the host galaxies and environment of radio-loud AGN. In this third paper we study the properties of a sample of Type-2 AGN that were selected on the basis of their [2-10] keV X-ray luminosity. We find that the X-ray luminosity function is in good agreement with previous studies and that the fraction of galaxies hosting an X-ray AGN is a strong function of the stellar mass of the host galaxy. The shape of this fraction-mass relation is similar to the fraction of galaxies that are emission-line AGN, while it differs significantly from the relation observed for radio-selected AGN. The AGN in our sample tend to be located in underdense environments where galaxy mergers and interactions are likely to occur. For all host galaxy masses, the Type-2 AGN display a strong infrared excess at short (~3.5 μm) wavelengths, suggesting the presence of hot dust possibly associated with a hot dusty torus. These results add weight to the belief that the X-ray selection criteria identifies a population of AGN similar to the emission-line selected population but distinct from the radio population at high masses. Appendix A is only available in electronic form at http://www.aanda.org

  14. HOST GALAXY PROPERTIES OF THE SWIFT BAT ULTRA HARD X-RAY SELECTED ACTIVE GALACTIC NUCLEUS

    SciTech Connect

    Koss, Michael; Mushotzky, Richard; Veilleux, Sylvain; Winter, Lisa M.; Baumgartner, Wayne; Tueller, Jack; Gehrels, Neil; Valencic, Lynne

    2011-10-01

    We have assembled the largest sample of ultra hard X-ray selected (14-195 keV) active galactic nucleus (AGN) with host galaxy optical data to date, with 185 nearby (z < 0.05), moderate luminosity AGNs from the Swift BAT sample. The BAT AGN host galaxies have intermediate optical colors (u - r and g - r) that are bluer than a comparison sample of inactive galaxies and optically selected AGNs from the Sloan Digital Sky Survey (SDSS) which are chosen to have the same stellar mass. Based on morphological classifications from the RC3 and the Galaxy Zoo, the bluer colors of BAT AGNs are mainly due to a higher fraction of mergers and massive spirals than in the comparison samples. BAT AGNs in massive galaxies (log M{sub *} >10.5) have a 5-10 times higher rate of spiral morphologies than in SDSS AGNs or inactive galaxies. We also see enhanced far-infrared emission in BAT AGN suggestive of higher levels of star formation compared to the comparison samples. BAT AGNs are preferentially found in the most massive host galaxies with high concentration indexes indicative of large bulge-to-disk ratios and large supermassive black holes. The narrow-line (NL) BAT AGNs have similar intrinsic luminosities as the SDSS NL Seyferts based on measurements of [O III] {lambda}5007. There is also a correlation between the stellar mass and X-ray emission. The BAT AGNs in mergers have bluer colors and greater ultra hard X-ray emission compared to the BAT sample as a whole. In agreement with the unified model of AGNs, and the relatively unbiased nature of the BAT sources, the host galaxy colors and morphologies are independent of measures of obscuration such as X-ray column density or Seyfert type. The high fraction of massive spiral galaxies and galaxy mergers in BAT AGNs suggest that host galaxy morphology is related to the activation and fueling of local AGN.

  15. Variable X-Ray and UV emission from AGB stars: Accretion activity associated with binarity

    NASA Astrophysics Data System (ADS)

    Sahai, Raghvendra; Sanz-Forcada, Jorge; Sánchez Contreras, Carmen

    2016-07-01

    Almost all of our current understanding of the late evolutionary stages of (1 — 8) Mʘ stars is based on single-star models. However, binarity can drastically affect late stellar evolution, producing dramatic changes in the history and geometry of mass loss that occurs in stars as they evolve off the AGB to become planetary nebulae (PNe). A variety of binary models have been proposed, which can lead to the generation of accretion disks and magnetic fields, which in turn produce the highly collimated jets that have been proposed as the primary agents for the formation of bipolar and multipolar PNe. However, observational evidence of binarity in AGB stars is sorely lacking simply these stars are very luminous and variable, invalidating standard techniques for binary detection. Using an innovative technique of searching for UV emission from AGB stars with GALEX, we have identified a class of AGB stars with far- ultraviolet excesses (fuvAGB stars), that are likely candidates for active accretion associated with a binary companion. We have carried out a pilot survey for X-ray emission from fuvAGB stars. The X-ray fluxes are found to vary in a stochastic or quasi-periodic manner on roughly hour-long times-scales, and simultaneous UV observations show similar variations in the UV fluxes. We discuss several models for the X-ray emission and its variability and find that the most likely scenario for the origin of the X-ray (and FUV) emission involves accretion activity around a main-sequence companion star, with confinement by strong magnetic fields associated with the companion and/or an accretion disk around it.

  16. Laboratory x ray lasers

    NASA Astrophysics Data System (ADS)

    Matthews, D. L.

    1989-08-01

    One of the most innovative spinoffs of ICF technology and physics was the development of the x ray wavelength laser. The first incontrovertible demonstration of this type of laser came from LLNL in 1984 using the Novette laser to pump a selenium foil target. The power and energy of Novette were then needed to produce a column of plasma of sufficient length to achieve a sufficient gainlength product (approximately 5.5, this corresponds to an amplification of approximately 250X) that could unquestionably illustrate the lasing effect. LLNL ICF expertise was also required to develop time-resolved spectrometers used to view the lasing transitions at approximately 20 nm, a region of the XUV spectrum normally dominated by high backgrounds. The design of the x ray laser amplifier, which required maintaining nonequilibrium level populations in a tailored plasma having the proper conditions for gain and x ray laser beam propagation, was accomplished with modified versions of ICF kinetics and hydrodynamics codes. Since the first demonstration, progress in the development of the x ray laser was rapid. New achievements include production of megawatt power levels at 20 nm, amplified spontaneous emission levels approaching saturation intensity GL of approximately 17 at 20 nm, efficiency (x ray laser energy/pump energy) approximately 10(exp 6), the demonstration of double and triple pass amplification (hinting at the possibility of producing x ray wavelength resonators), the focusing of x ray lasers to pump other types of lasers and the first demonstration of an x ray hologram produced by an x ray laser. The generation of amplification at ever shorter wavelength is possible using various types of inversion schemes. We depict below this progress benchmarked against production of gain in the water window (2.2 to 4.4 nm,), where applications to biological imaging may be facilitated.

  17. Shock Timing and Radiation Temperature in National Ignition Campaign Holhraum Tuning Experiments using the Dante X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Radousky, H. B.; Robey, H. F.; Widmann, K.; Moody, J. D.; Landen, O. L.

    2011-06-01

    Indirect drive ignition on the National Ignition Facility (NIF) utilizes a sequence of four shocks to compress a spherically-shaped fuel capsule within a laser heated gold hohlraum target. The soft x-ray power diagnostic DANTE, provides the important capability of measuring the spectrally and temporally resolved absolute x-ray emission flux from the hohlraum. Up to 18 x-ray diodes are fielded on DANTE which allows continuous spectral coverage from 50eV to 20,000 eV. This spectral range fully covers the black body radiation and the characteristic M-band and L-band emission from the high-Z target. Energetics experiments on NIF produce over 10 TW/sr of peak x-ray flux which corresponds to peak radiation temperatures near 300 eV (3.5 Million Deg. K). The Dante measured flux and radiation temperature are correlated with measurements of important shock parameters such as the break out times and shock velocity for the complex shock timing sequence. We will discuss the rationale for this shock configuration and show how recent Dante data can improve confidence in tuning adjustments to the laser and target parameters for achieving ignition. Prepared by LLNL under Contract DE-AC52-07NA27344.

  18. Analysis of Active Figure Control Effects on Mounting Strategy for X-Ray Optics

    NASA Technical Reports Server (NTRS)

    Kolodziejczak, Jeffrey J.; Roche, Jacqueline M.; O'Dell, Stephen L.; Ramsey, Brian D.; Elsner, Ryan F.; Gubarev, Mikhail V.; Weisskopf, Martin C.

    2014-01-01

    As part of ongoing development efforts at MSFC, we have begun to investigate mounting strategies for highly nested x-ray optics in both full-shell and segmented configurations. The analytical infrastructure for this effort also lends itself to investigation of active strategies. We expect that a consequence of active figure control on relatively thin substrates is that errors are propagated to the edges, where they might affect the effective precision of the mounting points. Based upon modeling, we describe parametrically, the conditions under which active mounts are preferred over fixed ones, and the effect of active figure corrections on the required number, locations, and kinematic characteristics of mounting points.

  19. X-ray spectra and time variability of active galactic nuclei

    NASA Technical Reports Server (NTRS)

    Mushotzky, R. F.

    1984-01-01

    The X-ray spectra of broad line active galactic nuclei (AGN) of all types (Seyfert I's, NELG's, broadline radio galaxies) are well fit by a power law in the .5 to 100 keV band of man energy slope alpha = .68 + or - .15. There is, as yet, no strong evidence for time variability of this slope in a given object. The constraints that this places on simple models of the central energy source are discussed. BL Lac objects have quite different X-ray spectral properties and show pronounced X-ray spectral variability. On time scales longer than 12 hours most radio quiet AGN do not show strong, delta I/I .5, variability. The probability of variability of these AGN seems to be inversely related to their luminosity. However characteristics timescales for variability have not been measured for many objects. This general lack of variability may imply that most AGN are well below the Eddington limit. Radio bright AGN tend to be more variable than radio quiet AGN on long, tau approx 6 month, timescales.

  20. X-ray/microwave relation of different types of active stars

    NASA Technical Reports Server (NTRS)

    Guedel, Manuel; Benz, Arnold O.

    1993-01-01

    Coronal active stars of seven classes between spectral types F and M, single and double, are compared in their quiescent radio and X-ray luminosities L(R) and L(X). We find, largely independent of stellar class, log L(X) is less than about log L(R) + 15.5. This general relation points to an intimate connection between the nonthermal, energetic electrons causing the radio emission and the bulk plasma of the corona responsible for thermal X-rays. The relation, observed over six orders of magnitude, suggests that the heating mechanism necessarily involves particle acceleration. We derive requirements for simple models based on optically thin gyrosynchrotron emission of mildly relativistic electrons and thermal X-rays from the bulk plasma. We discuss the possibility that a portion of the accelerated particles heats the ambient plasma by collisions. More likely, plasma heating and particle acceleration may occur in parallel and in the same process, but at a fixed ratio.

  1. X-RAY PROPERTIES EXPECTED FROM ACTIVE GALACTIC NUCLEUS FEEDBACK IN ELLIPTICAL GALAXIES

    SciTech Connect

    Pellegrini, Silvia; Ciotti, Luca; Ostriker, Jeremiah P.

    2012-01-01

    Detailed hydrodynamic simulations of active galactic nucleus feedback have been performed including the effects of radiative and mechanical momentum and energy input on the interstellar medium (ISM) of typical elliptical galaxies. We focus on the observational properties of the models in the soft and hard X-ray bands: nuclear X-ray luminosity; global X-ray luminosity and temperature of the hot ISM; and temperature and X-ray brightness profiles before, during, and after outbursts. After {approx}10 Gyr, the bolometric nuclear emission L{sub BH} is very sub-Eddington (l = L{sub BH}/L{sub Edd} {approx} 10{sup -4}), and within the range observed, though larger than typical values. Outbursts last for Almost-Equal-To 10{sup 7} yr, and the duty cycle of nuclear activity is a few Multiplication-Sign (10{sup -3} to 10{sup -2}), over the last 6 Gyr. The ISM thermal luminosity L{sub X} oscillates in phase with the nuclear luminosity, with broader peaks. This behavior helps statistically reproduce the observed large L{sub X} variation. The average gas temperature is within the observed range, in the upper half of those observed. In quiescence, the temperature profile has a negative gradient; thanks to past outbursts, the brightness profile lacks the steep shape of cooling flow models. After outbursts, disturbances are predicted in the temperature and brightness profiles (analyzed by unsharp masking). Most significantly, during major accretion episodes, a hot bubble of shocked gas is inflated at the galaxy center (within Almost-Equal-To 100 pc); the bubble would be conical in shape in real galaxies and would be radio-loud. Its detection in X-rays is within current capabilities, though it would likely remain unresolved. The ISM resumes its smooth appearance on a timescale of Almost-Equal-To 200 Myr; the duty cycle of perturbations in the ISM is of the order of 5%-10%. While showing general agreement between the models and real galaxies, this analysis indicates that additional

  2. Morphologies of Radio-, X-ray-, and Mid-infrared-selected Active Galactic Nuclei

    NASA Astrophysics Data System (ADS)

    Griffith, Roger L.; Stern, Daniel

    2010-08-01

    We investigate the optical morphologies of candidate active galaxies identified at radio, X-ray, and mid-infrared wavelengths. We use the Advanced Camera for Surveys General Catalog (ACS-GC) to identify 372, 1360, and 1238 active galactic nucleus (AGN) host galaxies from Very Large Array, XMM-Newton, and Spitzer Space Telescope observations of the COSMOS field, respectively. We investigate both quantitative (GALFIT) and qualitative (visual) morphologies of these AGN host galaxies, split by brightness in their selection band. We find that the samples are largely distinct, though extensive overlap exists between certain samples, most particularly for the X-ray- and mid-IR-selected sources with unresolved optical morphologies. We find that the radio-selected AGNs are most distinct, with a very low incidence of having unresolved optical morphologies and a high incidence of being hosted by early-type galaxies. In comparison to X-ray-selected AGNs, mid-IR-selected AGNs have a slightly higher incidence of being hosted by disk galaxies. These morphological results conform to the results of Hickox et al. who studied the colors and large-scale clustering of AGNs and found a general association of radio-selected AGNs with "red sequence" galaxies, mid-IR-selected AGNs with "blue cloud" galaxies, and X-ray-selected AGNs straddling these samples in the "green valley." We also find that optical brightness scales with X-ray and mid-IR brightnesses, while little correlation is evident between optical and radio brightnesses. This suggests that X-ray- and mid-IR-selected AGNs have similar Eddington ratios, while radio-selected AGNs represent a different accretion mechanism with a lower and wider range of Eddington ratios. In the general scenario where AGN activity marks and regulates the transition from late-type disk galaxies into massive elliptical galaxies, this work suggests that the earlier stages are most evident as mid-IR-selected AGNs. Mid-IR emission is less susceptible to

  3. Measurement of core plasma temperature and rotation on W7-X made available by the x-ray imaging crystal spectrometer (XICS)

    SciTech Connect

    Pablant, N A; Bitter, M; Burhenn, R; Delgado-Aparicio, L; Ellis, R; Gates, D; Goto, M; Hill, K W; Langenberg, A; Lazerson, S; Mardenfeld, M; Morita, S; Neilson, G H; Oishi, T; Pedersen, T S

    2014-07-01

    A new x-ray imaging crystal spectrometer diagnostic (XICS) is currently being built for installation on W7-X. This diagnostic will contribute to the study of ion and electron thermal transport and the evolution of the radial electric field by providing high resolution temperature and rotation measurements under many plasma conditions, including ECH heated plasmas. Installation is expected before the first experimental campaign (OP1.1), making an important set of measurements available for the first W7-X plasmas. This diagnostic will also work in concert with the HR-XCS diagnostic to provide an excellent diagnostic set for core impurity transport on W7-X.

  4. Solar Wind Charge Exchange X-ray emission from Mercury’s exosphere: Detectability with Bepi Colombo’s MIXS spectrometer

    NASA Astrophysics Data System (ADS)

    Koutroumpa, Dimitra; Dennerl, Konrad; Leblanc, François; Modolo, Ronan

    2015-11-01

    We have conducted preliminary hybrid simulations to calculate the Solar Wind Charge Exchange (SWCX) X-ray emission in Mercury’s exosphere. Our results imply that the OVII triplet emission intensity for standard slow solar wind conditions is of the same order as the one predicted by simulations for Mars and measured by Chandra in past observations of Mars. Using an oversimplified detector and observation geometry we explore the detectability of Mercury's SWCX emission by the MIXS spectrometer on board Bepi Colombo’s planetary orbiter (MPO).

  5. Determination of heavy metals concentrations in airborne particulates matter (APM) from Manjung district, Perak using energy dispersive X-ray fluorescence (EDXRF) spectrometer

    NASA Astrophysics Data System (ADS)

    Arshad, Nursyairah; Hamzah, Zaini; Wood, Ab. Khalik; Saat, Ahmad; Alias, Masitah

    2015-04-01

    Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 µg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated.

  6. Refinement of the Compton-Rayleigh scatter ratio method for use on the Mars Science Laboratory alpha particle X-ray spectrometer: II - Extraction of invisible element content

    NASA Astrophysics Data System (ADS)

    Perrett, Glynis M.; Campbell, John L.; Gellert, Ralf; King, Penelope L.; Nield, Emily; O'Meara, Joanne M.; Pradler, Irina

    2016-02-01

    The intensity ratio C/R between Compton and Rayleigh scatter peaks of the exciting Pu L X-rays in the alpha particle X-ray spectrometer (APXS) is strongly affected by the presence of very light elements such as oxygen which cannot be detected directly by the APXS. C/R values are determined along with element concentrations by fitting APXS spectra of geochemical reference materials (GRMs) with the GUAPX code. A quantity K is defined as the ratio between the C/R value determined by Monte Carlo simulation based on the measured element concentrations and the fitted C/R value from the spectrum. To ensure optimally accurate K values, the choice of appropriate GRMs is explored in detail, with attention paid to Rb and Sr, whose characteristic Kα X-ray peaks overlap the Pu Lα scatter peaks. The resulting relationship between the ratio K and the overall oxygen fraction is linear. This provides a calibration from which the concentration of additional light invisible constituents (ALICs) such as water may be estimated in unknown rock and conglomerate samples. Several GRMs are used as 'unknowns' in order to evaluate the accuracy of ALIC concentrations derived in this manner.

  7. Active galactic nucleus X-ray variability in the XMM-COSMOS survey

    SciTech Connect

    Lanzuisi, G.; Ponti, G.; Salvato, M.; Brusa, M.; Nandra, P. K.; Merloni, A.; Rosario, D.; Hasinger, G.; Sanders, D.; Cappelluti, N.; Comastri, A.; Gilli, R.; Bongiorno, A.; Lusso, E.; Steinhardt, C.; Silverman, J.; Schramm, M.; Trump, J.; and others

    2014-02-01

    We used the observations carried out by XMM in the COSMOS field over 3.5 yr to study the long term variability of a large sample of active galactic nuclei (AGNs) (638 sources) in a wide range of redshifts (0.1 < z < 3.5) and X-ray luminosities (10{sup 41} < L {sub 0.5-10} <10{sup 45.5}). Both a simple statistical method to assess the significance of variability and the Normalized Excess Variance (σ{sub rms}{sup 2}) parameter were used to obtain a quantitative measurement of the variability. Variability is found to be prevalent in most AGNs, whenever we have good statistics to measure it, and no significant differences between type 1 and type 2 AGNs were found. A flat (slope –0.23 ± 0.03) anti-correlation between σ{sub rms}{sup 2} and X-ray luminosity is found when all significantly variable sources are considered together. When divided into three redshift bins, the anti-correlation becomes stronger and evolving with z, with higher redshift AGNs being more variable. We prove, however, that this effect is due to the pre-selection of variable sources: when considering all of the sources with an available σ{sub rms}{sup 2} measurement, the evolution in redshift disappears. For the first time, we were also able to study long term X-ray variability as a function of M {sub BH} and Eddington ratio for a large sample of AGNs spanning a wide range of redshifts. An anti-correlation between σ{sub rms}{sup 2} and M {sub BH} is found, with the same slope of anti-correlation between σ{sub rms}{sup 2} and X-ray luminosity, suggesting that the latter may be a by-product of the former. No clear correlation is found between σ{sub rms}{sup 2} and the Eddington ratio in our sample. Finally, no correlation is found between the X-ray σ{sub rms}{sup 2} and optical variability.

  8. Renewed Activity from the X-Ray Transient SAXJ 1810.8-2609 with Integral

    NASA Astrophysics Data System (ADS)

    Fiocchi, M.; Natalucci, L.; Chenevez, J.; Bazzano, A.; Tarana, A.; Ubertini, P.; Brandt, S.; Beckmann, V.; Federici, M.; Galis, R.; Hudec, R.

    2009-03-01

    We report on the results of International Gamma-Ray Astrophysics Laboratory (INTEGRAL) observations of the neutron star low-mass X-ray binary SAX J1810.8-2609 during its latest active phase in 2007 August. The current outburst is the first one since 1998 and the derived luminosity is 1.1-2.6 ×1036 erg s-1 in the 20-100 keV energy range. This low outburst luminosity and the long-term time-average accretion rate of ~5 × 10-12 M sun yr-1 suggest that SAX J1810.8-2609 is a faint soft X-ray transient. During the flux increase, spectra are consistent with a thermal Comptonization model with a temperature plasma of kT e~ 23-30 keV and an optical depth of τ~ 1.2-1.5, independent of the luminosity of the system. This is a typical low hard spectral state for which the X-ray emission is attributed to the upscattering of soft seed photons by a hot, optically thin electron plasma. During the decay, spectra have a different shape, the high energy tail being compatible with a single power law. This confirm similar behavior observed by BeppoSAX during the previous outburst, with the absence of visible cutoff in the hard X-ray spectrum. INTEGRAL/JEM-X instrument observed four X-ray bursts in Fall 2007. The first one has the highest peak flux (≈3.5 crab in 3-25 keV) giving an upper limit to the distance of the source of about 5.7 kpc, for a L Edd ≈ 3.8 × 1038 erg s-1. The observed recurrence time of ~ 1.2 days and the ratio of the total energy emitted in the persistent flux to that emitted in the bursts (α~ 73) allow us to conclude that the burst fuel was composed by mixed hydrogen and helium with X >= 0.4. INTEGRAL is an ESA project with Instruments and Science Data Center funded by ESA member states, especially the PI countries: Denmark, France, Germany, Italy, Switzerland, Spain; Czech Republic and Poland; and with the participation of Russia and USA.

  9. Barbiturate bearing aroylhydrazine derivatives: Synthesis, NMR investigations, single crystal X-ray studies and biological activity

    NASA Astrophysics Data System (ADS)

    Giziroglu, Emrah; Sarikurkcu, Cengiz; Aygün, Muhittin; Basbulbul, Gamze; Soyleyici, H. Can; Firinci, Erkan; Kirkan, Bulent; Alkis, Ayse; Saylica, Tayfur; Biyik, Halil

    2016-03-01

    A series of barbituric acid aroylhydrazine derivatives have been prepared from their corresponding 1,3-dimethyl-5-acetyl barbituric acid and aroylhydrazines. All compounds have been fully characterized by using FT-IR, multinuclear NMR (1H, 13C) and Mass (MS) spectrometry. We also describe the X-ray crystal structure of 3a, which crystallizes in the monoclinic P21/n space group. The crystal structure is stabilized with infinite linear chains of dimeric units. Furthermore, all compounds were investigated for their tyrosinase inhibition, antioxidative and antimicrobial activies. The results from biological activity assays have shown that all of compounds have excellent antioxidant, significant tyrosinase inhibition and moderate antimicrobial activity.

  10. A recent strong X-ray flaring activity of 1ES 1959+650 with possibly less efficient stochastic acceleration

    NASA Astrophysics Data System (ADS)

    Kapanadze, B.; Dorner, D.; Vercellone, S.; Romano, P.; Kapanadze, S.; Mdzinarishvili, T.

    2016-09-01

    We present an X-ray flaring activity of 1ES 1959+650 in 2015 August-2016 January, which was the most powerful and prolonged during the 10.75 yr period since the start of its monitoring with X-ray Telescope onboard Swift. A new highest historical 0.3-10 keV count rate was recorded three times that makes this object the third BL Lacertae source exceeding the level of 20 counts s-1. Along with the overall variability by a factor of 5.7, this epoch was characterized by fast X-ray flares by a factor of 2.0-3.1, accompanied with an extreme spectral variability. The source also shows a simultaneous flaring activity in the optical - UV and 0.3-100 GeV bands, although a fast γ-ray flare without significant optical - X-ray counterparts is also found. In contrast to the X-ray flares in the previous years, the stochastic acceleration seems be less important for the electrons responsible for producing X-ray emission during this flare that challenges the earlier suggestion that the electrons in the jets of TeV-detected BL Lacertae objects should undergo an efficient stochastic acceleration resulting in a lower X-ray spectral curvature.

  11. Performance verification and system integration tests of the pulse shape processor for the soft x-ray spectrometer onboard ASTRO-H

    NASA Astrophysics Data System (ADS)

    Takeda, Sawako; Tashiro, Makoto S.; Ishisaki, Yoshitaka; Tsujimoto, Masahiro; Seta, Hiromi; Shimoda, Yuya; Yamaguchi, Sunao; Uehara, Sho; Terada, Yukikatsu; Fujimoto, Ryuichi; Mitsuda, Kazuhisa

    2014-07-01

    The soft X-ray spectrometer (SXS) aboard ASTRO-H is equipped with dedicated digital signal processing units called pulse shape processors (PSPs). The X-ray microcalorimeter system SXS has 36 sensor pixels, which are operated at 50 mK to measure heat input of X-ray photons and realize an energy resolution of 7 eV FWHM in the range 0.3-12.0 keV. Front-end signal processing electronics are used to filter and amplify the electrical pulse output from the sensor and for analog-to-digital conversion. The digitized pulses from the 36 pixels are multiplexed and are sent to the PSP over low-voltage differential signaling lines. Each of two identical PSP units consists of an FPGA board, which assists the hardware logic, and two CPU boards, which assist the onboard software. The FPGA board triggers at every pixel event and stores the triggering information as a pulse waveform in the installed memory. The CPU boards read the event data to evaluate pulse heights by an optimal filtering algorithm. The evaluated X-ray photon data (including the pixel ID, energy, and arrival time information) are transferred to the satellite data recorder along with event quality information. The PSP units have been developed and tested with the engineering model (EM) and the flight model. Utilizing the EM PSP, we successfully verified the entire hardware system and the basic software design of the PSPs, including their communication capability and signal processing performance. In this paper, we show the key metrics of the EM test, such as accuracy and synchronicity of sampling clocks, event grading capability, and resultant energy resolution.

  12. X-ray generator

    DOEpatents

    Dawson, John M.

    1976-01-01

    Apparatus and method for producing coherent secondary x-rays that are controlled as to direction by illuminating a mixture of high z and low z gases with an intense burst of primary x-rays. The primary x-rays are produced with a laser activated plasma, and these x-rays strip off the electrons of the high z atoms in the lasing medium, while the low z atoms retain their electrons. The neutral atoms transfer electrons to highly excited states of the highly striped high z ions giving an inverted population which produces the desired coherent x-rays. In one embodiment, a laser, light beam provides a laser spark that produces the intense burst of coherent x-rays that illuminates the mixture of high z and low z gases, whereby the high z atoms are stripped while the low z ones are not, giving the desired mixture of highly ionized and neutral atoms. To this end, the laser spark is produced by injecting a laser light beam, or a plurality of beams, into a first gas in a cylindrical container having an adjacent second gas layer co-axial therewith, the laser producing a plasma and the intense primary x-rays in the first gas, and the second gas containing the high and low atomic number elements for receiving the primary x-rays, whereupon the secondary x-rays are produced therein by stripping desired ions in a neutral gas and transfer of electrons to highly excited states of the stripped ions from the unionized atoms. Means for magnetically confining and stabilizing the plasma are disclosed for controlling the direction of the x-rays.

  13. Two Years of Chemical Sampling on Meridiani Planum by the Alpha Particle X-Ray Spectrometer Onboard the Mars Exploration Rover Opportunity

    NASA Technical Reports Server (NTRS)

    Bruckner, J.; Gellert, R.; Clark, B.C.; Dreibus, G.; Rieder, R.; Wanke, H.; d'Uston, C.; Economou, T.; Klingelhofer, G.; Lugmair, G.; Ming, D.W.; Squyres, S.W.; Yen, A.; Zipfel, J.

    2006-01-01

    For over two terrestrial years, the Mars Exploration Rover Opportunity has been exploring the martian surface at Meridiani Planum using the Athena instrument payload [1], including the Alpha Particle X-Ray Spectrometer (APXS). The APXS has a small sensor head that is mounted on the robotic arm of the rover. The chemistry, mineralogy and morphology of selected samples were investigated by the APXS along with the Moessbauer Spectrometer (MB) and the Microscopic Imager (MI). The Rock Abrasion Tool (RAT) provided the possibility to dust and/or abrade rock surfaces down to several millimeters to expose fresh material for analysis. We report here on APXS data gathered along the nearly 6-kilometers long traverse in craters and plains of Meridiani.

  14. Review of active optics methods in astronomy from x-rays to the infrared

    NASA Astrophysics Data System (ADS)

    Lemaitre, Gérard R.

    2010-09-01

    This review on Active Optics Methods presents various concepts of deformable uv, visible and ir telescope optics which have been mainly developed at the Marseille Observatory - for now 40 years - and other institutes. An optical surface generated by active optics and spherical figuring is free from high spatial frequency errors i.e. ripple errors. Active Optics allows applications of new concepts as: stress figuring aspherization processes, variable curvature mirrors, in situ stressing aspherization processes, under stress replications to generate corrected diffraction gratings, multimode deformable compensators, and situ control of large telescope optics. X-ray telescope mirrors could also benefit soon from the enhanced imaging performances of active optics. The 0.5- 1 arcsec spatial resolution of Chandra should be followed up by increased resolution space telescopes. This requires constructing new grazing-incidence telescopes which will strictly satisfy Abbe's sine condition, i.e. a Chase-VanSpeybroeck design for the two-mirror case. The recent elaboration of an elasticity theory of weakly conical shells allows reviewing some potential innovative concepts for the active figuring and in situ control of either monolithic or segmented telescope mirrors for x-ray astronomy.

  15. Understanding X-ray Spectral and Timing Characteristics of Active Galactic Nuclei by a Novel Picture with Multiple Primary Emission

    NASA Astrophysics Data System (ADS)

    Noda, H.; Makishima, K.; Yamada, S.; Miyake, K.

    2014-07-01

    Our understanding of the central engine of type I Active Galactic Nuclei (AGNs) has been hampered by spectral ambiguity among different X-ray components: e.g., Comptonized primary emission, secondary components possibly affected by strong relativistic effects (e.g., Miniutti et al. 2007), and/or complex partial absorption (e.g., Miller et al. 2008). With a variability-assisted spectral analysis method developed in Noda et al. (2011, 2013), we succeeded in model-independently decomposing the AGN spectra, and establishing a novel view of the engine, that it consists of multiple primary X-ray continua with distinct spectral shapes, variability timescales, and Eddington-ratio dependences (Noda et al. 2013). The novel view with the multiple primary X-ray components can explain several long-lasting problems with the AGN central engine. The hardest of the primary components can now partially explain the "too strong hard X-ray hump", and make the secondary reflection strength moderate. The well-known X-ray spectral softening, when a source brightens, can be successfully reproduced by an increasing dominance of a softer-slope primary component towards higher Eddington ratios. Furthermore, the puzzling lack of good optical vs. X-ray intensity correlation, in some AGNs, can be solved by considering that the optical emission is correlated only with some of the primary X-ray components.

  16. Transient X-ray burster KS 1741-293 active again

    NASA Astrophysics Data System (ADS)

    Kuulkers, E.; Alfonso-Garzon, J.; Beckmann, V.; Bird, T.; Brandt, S.; Chenevez, J.; Courvoisier, T.; Del Santo, M.; Domingo, A.; Ebisawa, K.; Jonker, P.; Kretschmar, P.; Markwardt, C.; Oosterbroek, T.; Paizis, A.; Pottschmidt, K.; Sanchez-Fernandez, C.; Wijnands, R.

    2013-02-01

    The transient X-ray burster KS 1741-293 (e.g., ATel #1531, #2465, #3632, #3646) has become active again. During observations as part of the INTEGRAL Galactic bulge monitoring program (see ATel #438) on (UT) 22 February 2013 15:22-19:04 and 24 February 07:04-10:45, the source brightened from 16+/-2 to 22+/-2 mCrab and 13+/-2 to 17+/-2 mCrab in the IBIS/ISGRI 18-40 and 40-100 keV bands, respectively.

  17. Coordinated Observations of X-ray and High-resolution EUV Active Region Dynamics

    NASA Technical Reports Server (NTRS)

    Savage, Sabrina

    2013-01-01

    The recently-launched High-resolution Coronal imager (Hi-C) sounding rocket provided the highest resolution images of coronal loops and other small-scale structures in the 193 Angstrom passband to date. With just 5 minutes of observations, the instrument recorded a variety of dynamic coronal events -- including even a small B-class flare. We will present our results comparing these extreme-ultraviolet (EUV) observations with X-ray imaging from Hinode/XRT as well as EUV AIA data to identify sources of hot plasma rooted in the photosphere and track their affect on the overall topology and dynamics of the active region.

  18. Coordinated Observations of X-ray and High-Resolution EUV Active Region Dynamics

    NASA Technical Reports Server (NTRS)

    Savage, Sabrina; Cirtain, Jonathan; Winebarger, Amy; Kobayashi, Ken; Golub, Leon; Korreck, Kelly

    2013-01-01

    The recently-launched High-resolution Coronal imager (Hi-C) sounding rocket provided the highest resolution images of coronal loops and other small-scale structures in the 193 Angstrom passband to date. With just 5 minutes of observations, the instrument recorded a variety of dynamic coronal events -- including even a small B-class flare. We will present our results comparing these extreme-ultraviolet (EUV) observations with X-ray imaging from Hinode/XRT as well as EUV AIA data to identify sources of hot plasma rooted in the photosphere and track their affect on the overall topology and dynamics of the active region.

  19. Determination of carrier yields for neutron activation analysis using energy dispersive X-ray spectrometry

    USGS Publications Warehouse

    Johnson, R.G.; Wandless, G.A.

    1984-01-01

    A new method is described for determining carrier yield in the radiochemical neutron activation analysis of rare-earth elements in silicate rocks by group separation. The method involves the determination of the rare-earth elements present in the carrier by means of energy-dispersive X-ray fluorescence analysis, eliminating the need to re-irradiate samples in a nuclear reactor after the gamma ray analysis is complete. Results from the analysis of USGS standards AGV-1 and BCR-1 compare favorably with those obtained using the conventional method. ?? 1984 Akade??miai Kiado??.

  20. Synchrotron based X-ray fluorescence activities at Indus-2: An overview

    SciTech Connect

    Tiwari, M. K.

    2014-04-24

    X-Ray fluorescence (XRF) spectrometry is a powerful non-destructive technique for elemental analysis of materials at bulk and trace concentration levels. Taking into consideration several advantages of the synchrotron based XRF technique and to fulfill the requirements of Indian universities users we have setup a microfocus XRF beamline (BL-16) on Indus-2 synchrotron light source. The beamline offers a wide range of usages – both from research laboratories and industries; and for researchers working in diverse fields. A brief overview of the measured performance of the beamline, design specifications including various attractive features and recent research activities carried out on the BL-16 beamline are presented.