Sample records for activity optimal tracers

  1. Optimization of 18 F-syntheses using 19 F-reagents at tracer-level concentrations and liquid chromatography/tandem mass spectrometry analysis: Improved synthesis of [18 F]MDL100907.

    PubMed

    Zhang, Xiang; Dunlow, Ryan; Blackman, Burchelle N; Swenson, Rolf E

    2018-05-15

    Traditional radiosynthetic optimization faces the challenges of high radiation exposure, cost, and inability to perform serial reactions due to tracer decay. To accelerate tracer development, we have developed a strategy to simulate radioactive 18 F-syntheses by using tracer-level (nanomolar) non-radioactive 19 F-reagents and LC-MS/MS analysis. The methodology was validated with fallypride synthesis under tracer-level 19 F-conditions, which showed reproducible and comparable results with radiosynthesis, and proved the feasibility of this process. Using this approach, the synthesis of [ 18 F]MDL100907 was optimized under 19 F-conditions with greatly improved yield. The best conditions were successfully transferred to radiosynthesis. A radiochemical yield of 19% to 22% was achieved with the radiochemical purity >99% and the molar activity 38.8 to 53.6 GBq/ μmol (n = 3). The tracer-level 19 F-approach provides a high-throughput and cost-effective process to optimize radiosynthesis with reduced radiation exposure. This new method allows medicinal and synthetic chemists to optimize radiolabeling conditions without the need to use radioactivity. Copyright © 2018 John Wiley & Sons, Ltd.

  2. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to providemore » the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.« less

  3. Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves' disease

    NASA Astrophysics Data System (ADS)

    Merrill, S.; Horowitz, J.; Traino, A. C.; Chipkin, S. R.; Hollot, C. V.; Chait, Y.

    2011-02-01

    Calculation of the therapeutic activity of radioiodine 131I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of 131I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four 'target variables': time-integrated activity coefficient, time of maximum activity, maximum activity, and effective half-life in the gland. Clinical data from 41 patients who underwent 131I therapy for Graves' disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model. The distributions of the target variables in the patient population are characterized. Using minimum root mean squared error as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal times. An algorithm is developed for computing the optimal 1-, 2-, and 3-point sampling schedules for the target variables. This algorithm is implemented in a freely available software tool. Taking into consideration 131I effective half-life in the thyroid and measurement noise, the optimal 1-point time for time-integrated activity coefficient is a measurement 1 week following the tracer dose. Additional measurements give only a slight improvement in accuracy.

  4. Defining optimal tracer activities in pediatric oncologic whole-body 18F-FDG-PET/MRI.

    PubMed

    Gatidis, Sergios; Schmidt, Holger; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schäfer, Jürgen F

    2016-12-01

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined 18 F-FDG-PET/MRI in pediatric oncology. 30 18 F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV mean and SUV max ) as well as SUV variation (SUV var ) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal 18 F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV mean and SUV max were below 5 % at 18 F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg 18 F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg 18 F-FDG or higher. Administration of 18 F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered 18 F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of 18 F-FDG or other tracers for specific clinical questions have to be further established in selected patient populations.

  5. Enhanced reaction kinetics in biological cells

    NASA Astrophysics Data System (ADS)

    Loverdo, C.; Bénichou, O.; Moreau, M.; Voituriez, R.

    2008-02-01

    The cell cytoskeleton is a striking example of an `active' medium driven out-of-equilibrium by ATP hydrolysis. Such activity has been shown to have a spectacular impact on the mechanical and rheological properties of the cellular medium, as well as on its transport properties: a generic tracer particle freely diffuses as in a standard equilibrium medium, but also intermittently binds with random interaction times to motor proteins, which perform active ballistic excursions along cytoskeletal filaments. Here, we propose an analytical model of transport-limited reactions in active media, and show quantitatively how active transport can enhance reactivity for large enough tracers such as vesicles. We derive analytically the average interaction time with motor proteins that optimizes the reaction rate, and reveal remarkable universal features of the optimal configuration. We discuss why active transport may be beneficial in various biological examples: cell cytoskeleton, membranes and lamellipodia, and tubular structures such as axons.

  6. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    PubMed

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose-reduced datasets based on clinical (18)F-FDG PET data demonstrated the clinical applicability of the proposed data. Simulation of PET tracer dose reduction is possible with retrospective undersampling of list-mode data. Resulting simulated low-dose images have equivalent characteristics with PET images actually measured at lower doses and can be used to derive optimal tracer dose regimes.

  7. Extracting maximum power from active colloidal heat engines

    NASA Astrophysics Data System (ADS)

    Martin, D.; Nardini, C.; Cates, M. E.; Fodor, É.

    2018-03-01

    Colloidal heat engines extract power out of a fluctuating bath by manipulating a confined tracer. Considering a self-propelled tracer surrounded by a bath of passive colloids, we optimize the engine performances based on the maximum available power. Our approach relies on an adiabatic mean-field treatment of the bath particles which reduces the many-body description into an effective tracer dynamics. It leads us to reveal that, when operated at constant activity, an engine can only produce less maximum power than its passive counterpart. In contrast, the output power of an isothermal engine, operating with cyclic variations of the self-propulsion without any passive equivalent, exhibits an optimum in terms of confinement and activity. Direct numerical simulations of the microscopic dynamics support the validity of these results even beyond the mean-field regime, with potential relevance to the design of experimental engines.

  8. 13C metabolic flux analysis: optimal design of isotopic labeling experiments.

    PubMed

    Antoniewicz, Maciek R

    2013-12-01

    Measuring fluxes by 13C metabolic flux analysis (13C-MFA) has become a key activity in chemical and pharmaceutical biotechnology. Optimal design of isotopic labeling experiments is of central importance to 13C-MFA as it determines the precision with which fluxes can be estimated. Traditional methods for selecting isotopic tracers and labeling measurements did not fully utilize the power of 13C-MFA. Recently, new approaches were developed for optimal design of isotopic labeling experiments based on parallel labeling experiments and algorithms for rational selection of tracers. In addition, advanced isotopic labeling measurements were developed based on tandem mass spectrometry. Combined, these approaches can dramatically improve the quality of 13C-MFA results with important applications in metabolic engineering and biotechnology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Optimal tracers for parallel labeling experiments and 13C metabolic flux analysis: A new precision and synergy scoring system.

    PubMed

    Crown, Scott B; Long, Christopher P; Antoniewicz, Maciek R

    2016-11-01

    13 C-Metabolic flux analysis ( 13 C-MFA) is a widely used approach in metabolic engineering for quantifying intracellular metabolic fluxes. The precision of fluxes determined by 13 C-MFA depends largely on the choice of isotopic tracers and the specific set of labeling measurements. A recent advance in the field is the use of parallel labeling experiments for improved flux precision and accuracy. However, as of today, no systemic methods exist for identifying optimal tracers for parallel labeling experiments. In this contribution, we have addressed this problem by introducing a new scoring system and evaluating thousands of different isotopic tracer schemes. Based on this extensive analysis we have identified optimal tracers for 13 C-MFA. The best single tracers were doubly 13 C-labeled glucose tracers, including [1,6- 13 C]glucose, [5,6- 13 C]glucose and [1,2- 13 C]glucose, which consistently produced the highest flux precision independent of the metabolic flux map (here, 100 random flux maps were evaluated). Moreover, we demonstrate that pure glucose tracers perform better overall than mixtures of glucose tracers. For parallel labeling experiments the optimal isotopic tracers were [1,6- 13 C]glucose and [1,2- 13 C]glucose. Combined analysis of [1,6- 13 C]glucose and [1,2- 13 C]glucose labeling data improved the flux precision score by nearly 20-fold compared to widely use tracer mixture 80% [1- 13 C]glucose +20% [U- 13 C]glucose. Copyright © 2016 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  10. Impact of community tracer teams on treatment outcomes among tuberculosis patients in South Africa.

    PubMed

    Bronner, Liza E; Podewils, Laura J; Peters, Annatjie; Somnath, Pushpakanthi; Nshuti, Lorna; van der Walt, Martie; Mametja, Lerole David

    2012-08-07

    Tuberculosis (TB) indicators in South Africa currently remain well below global targets. In 2008, the National Tuberculosis Program (NTP) implemented a community mobilization program in all nine provinces to trace TB patients that had missed a treatment or clinic visit. Implementation sites were selected by TB program managers and teams liaised with health facilities to identify patients for tracing activities. The objective of this analysis was to assess the impact of the TB Tracer Project on treatment outcomes among TB patients. The study population included all smear positive TB patients registered in the Electronic TB Registry from Quarter 1 2007-Quarter 1 2009 in South Africa. Subdistricts were used as the unit of analysis, with each designated as either tracer (standard TB program plus tracer project) or non-tracer (standard TB program only). Mixed linear regression models were utilized to calculate the percent quarterly change in treatment outcomes and to compare changes in treatment outcomes from Quarter 1 2007 to Quarter 1 2009 between tracer and non-tracer subdistricts. For all provinces combined, the percent quarterly change decreased significantly for default treatment outcomes among tracer subdistricts (-0.031%; p < 0.001) and increased significantly for successful treatment outcomes among tracer subdistricts (0.003%; p = 0.03). A significant decrease in the proportion of patient default was observed for all provinces combined over the time period comparing tracer and non-tracer subdistricts (p = 0.02). Examination in stratified models revealed the results were not consistent across all provinces; significant differences were observed between tracer and non-tracer subdistricts over time in five of nine provinces for treatment default. Community mobilization of teams to trace TB patients that missed a clinic appointment or treatment dose may be an effective strategy to mitigate default rates and improve treatment outcomes. Additional information is necessary to identify best practices and elucidate discrepancies across provinces; these findings will help guide the NTP in optimizing the adoption of tracing activities for TB control.

  11. An improved radiosynthesis of O-(2-[18 F]fluoroethyl)-O-(p-nitrophenyl)methylphosphonate: A first-in-class cholinesterase PET tracer.

    PubMed

    Neumann, Kiel D; Thompson, Charles M; Blecha, Joseph E; Gerdes, John M; VanBrocklin, Henry F

    2017-06-15

    O-(2-Fluoroethyl)-O-(p-nitrophenyl) methylphosphonate 1 is an organophosphate cholinesterase inhibitor that creates a phosphonyl-serine covalent adduct at the enzyme active site blocking cholinesterase activity in vivo. The corresponding radiolabeled O-(2-[ 18 F]fluoroethyl)-O-(p-nitrophenyl) methylphosphonate, [ 18 F]1, has been previously prepared and found to be an excellent positron emission tomography imaging tracer for assessment of cholinesterases in live brain, peripheral tissues, and blood. However, the previously reported [ 18 F]1 tracer synthesis was slow even with microwave acceleration, required high-performance liquid chromatography separation of the tracer from impurities, and gave less optimal radiochemical yields. In this paper, we report a new synthetic approach to circumvent these shortcomings that is reliant on the facile reactivity of bis-(O,O-p-nitrophenyl) methylphosphonate, 2, with 2-fluoroethanol in the presence of DBU. The cold synthesis was successfully translated to provide a more robust radiosynthesis. Using this new strategy, the desired tracer, [ 18 F]1, was obtained in a non-decay-corrected radiochemical yield of 8 ± 2% (n = 7) in >99% radiochemical and >95% chemical purity with a specific activity of 3174 ± 345 Ci/mmol (EOS). This new facile radiosynthesis routinely affords highly pure quantities of [ 18 F]1, which will further enable tracer development of OP cholinesterase inhibitors and their evaluation in vivo. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Evaluation of [(201)Tl](III) Vancomycin in normal rats.

    PubMed

    Jalilian, Amir Reza; Hosseini, Mohammad Amin; Majdabadi, Abbas; Saddadi, Fariba

    2008-01-01

    Tl-201 has potential in the preparation of radiolabelled compounds similar to its homologues, like In-111 and radiogallium. In this paper, recently prepared [(201)Tl](III) vancomycin complex ([(201)Tl](III)VAN) has been evaluated for its biological properties. [(201)Tl](III)VAN was prepared according to the optimized conditions followed by biodistribution studies in normal rats for up to 52 h. The Staphylococcus aurous specific binding was checked in vitro. The complex was finally injected to normal rats. Tracer SPECT images were obtained in normal animals and compared to those of (67)Ga-citrate. Freshly-prepared [(201)Tl](III)VAN batches (radiochemical yield > 99%, radiochemical purity > 98%, specific activity approximately 1.2 Ci/mmol) showed a similar biodistribution to that of unlabeled vancomycin. The microorganism binding ratios were 3 and 9 for tracer (201)Tl(3+) and tracer (201)Tl(III)DTPA, respectively, suggesting the preservation of the tracer bioactivity. As a nonspecific cell penetrating tracer, [(201)Tl](III)DTPA was used.

  13. Impact of community tracer teams on treatment outcomes among tuberculosis patients in South Africa

    PubMed Central

    2012-01-01

    Background Tuberculosis (TB) indicators in South Africa currently remain well below global targets. In 2008, the National Tuberculosis Program (NTP) implemented a community mobilization program in all nine provinces to trace TB patients that had missed a treatment or clinic visit. Implementation sites were selected by TB program managers and teams liaised with health facilities to identify patients for tracing activities. The objective of this analysis was to assess the impact of the TB Tracer Project on treatment outcomes among TB patients. Methods The study population included all smear positive TB patients registered in the Electronic TB Registry from Quarter 1 2007-Quarter 1 2009 in South Africa. Subdistricts were used as the unit of analysis, with each designated as either tracer (standard TB program plus tracer project) or non-tracer (standard TB program only). Mixed linear regression models were utilized to calculate the percent quarterly change in treatment outcomes and to compare changes in treatment outcomes from Quarter 1 2007 to Quarter 1 2009 between tracer and non-tracer subdistricts. Results For all provinces combined, the percent quarterly change decreased significantly for default treatment outcomes among tracer subdistricts (−0.031%; p < 0.001) and increased significantly for successful treatment outcomes among tracer subdistricts (0.003%; p = 0.03). A significant decrease in the proportion of patient default was observed for all provinces combined over the time period comparing tracer and non-tracer subdistricts (p = 0.02). Examination in stratified models revealed the results were not consistent across all provinces; significant differences were observed between tracer and non-tracer subdistricts over time in five of nine provinces for treatment default. Conclusions Community mobilization of teams to trace TB patients that missed a clinic appointment or treatment dose may be an effective strategy to mitigate default rates and improve treatment outcomes. Additional information is necessary to identify best practices and elucidate discrepancies across provinces; these findings will help guide the NTP in optimizing the adoption of tracing activities for TB control. PMID:22871071

  14. WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, H; Yeung, I; Milosevic, M

    2016-06-15

    Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths ofmore » the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.« less

  15. In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with Resovist.

    PubMed

    Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P; Ferguson, R Matthew; Kemp, Scott J; Ittrich, Harald; Krishnan, Kannan M; Adam, Gerhard; Knopp, Tobias

    2017-05-07

    Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n  =  3) received 60 µl LS-008 (87 mM) and the second (n  =  3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and perfusion studies.

  16. In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with Resovist

    NASA Astrophysics Data System (ADS)

    Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P.; Ferguson, R. Matthew; Kemp, Scott J.; Ittrich, Harald; Krishnan, Kannan M.; Adam, Gerhard; Knopp, Tobias

    2017-05-01

    Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n  =  3) received 60 µl LS-008 (87 mM) and the second (n  =  3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and perfusion studies.

  17. Joint reconstruction of dynamic PET activity and kinetic parametric images using total variation constrained dictionary sparse coding

    NASA Astrophysics Data System (ADS)

    Yu, Haiqing; Chen, Shuhang; Chen, Yunmei; Liu, Huafeng

    2017-05-01

    Dynamic positron emission tomography (PET) is capable of providing both spatial and temporal information of radio tracers in vivo. In this paper, we present a novel joint estimation framework to reconstruct temporal sequences of dynamic PET images and the coefficients characterizing the system impulse response function, from which the associated parametric images of the system macro parameters for tracer kinetics can be estimated. The proposed algorithm, which combines statistical data measurement and tracer kinetic models, integrates a dictionary sparse coding (DSC) into a total variational minimization based algorithm for simultaneous reconstruction of the activity distribution and parametric map from measured emission sinograms. DSC, based on the compartmental theory, provides biologically meaningful regularization, and total variation regularization is incorporated to provide edge-preserving guidance. We rely on techniques from minimization algorithms (the alternating direction method of multipliers) to first generate the estimated activity distributions with sub-optimal kinetic parameter estimates, and then recover the parametric maps given these activity estimates. These coupled iterative steps are repeated as necessary until convergence. Experiments with synthetic, Monte Carlo generated data, and real patient data have been conducted, and the results are very promising.

  18. Flow optimization study of a batch microfluidics PET tracer synthesizing device

    PubMed Central

    Elizarov, Arkadij M.; Meinhart, Carl; van Dam, R. Michael; Huang, Jiang; Daridon, Antoine; Heath, James R.; Kolb, Hartmuth C.

    2010-01-01

    We present numerical modeling and experimental studies of flow optimization inside a batch microfluidic micro-reactor used for synthesis of human-scale doses of Positron Emission Tomography (PET) tracers. Novel techniques are used for mixing within, and eluting liquid out of, the coin-shaped reaction chamber. Numerical solutions of the general incompressible Navier Stokes equations along with time-dependent elution scalar field equation for the three dimensional coin-shaped geometry were obtained and validated using fluorescence imaging analysis techniques. Utilizing the approach presented in this work, we were able to identify optimized geometrical and operational conditions for the micro-reactor in the absence of radioactive material commonly used in PET related tracer production platforms as well as evaluate the designed and fabricated micro-reactor using numerical and experimental validations. PMID:21072595

  19. Optimization of PET instrumentation for brain activation studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dahlbom, M.; Cherry, S.R.; Hoffman, E.J.

    By performing cerebral blood flow studies with positron emission tomography (PET), and comparing blood flow images of different states of activation, functional mapping of the brain is possible. The ability of current commercial instruments to perform such studies is investigated in this work, based on a comparison of noise equivalent count (NEC) rates. Differences in the NEC performance of the different scanners in conjunction with scanner design parameters, provide insights into the importance of block design (size, dead time, crystal thickness) and overall scanner design (sensitivity and scatter fraction) for optimizing data from activation studies. The newer scanners with removablemore » septa, operating with 3-D acquisition, have much higher sensitivity, but require new methodology for optimized operation. Only by administering multiple low doses (fractionation) of the flow tracer can the high sensitivity be utilized.« less

  20. Development of a (68)Ga-peptide tracer for PET GnRH1-imaging.

    PubMed

    Zoghi, Masoumeh; Jalilian, Amir R; Niazi, Ali; Johari-Daha, Fariba; Alirezapour, Behrouz; Ramezanpour, Saeed

    2016-07-01

    Total synthesis, quality control and preclinical evaluation of [(68)Ga]-DOTA-triptorelin ([(68)Ga]-DOTA-TRP) is reported as a possible PET radiotracer for GnRH receptor imaging. DOTA-TRP was totally synthesized in two steps and after characterization went through radiolabelling optimization studies followed by tracer stability. The biodistribution of the tracer in normal male rats and 4T1 tumour-bearing mice was performed in 120 min after i.v. injection. The peptide and the conjugates were synthesized with >95 % chemical purity. [(68)Ga]-DOTA-TRP complex was prepared in high radiochemical purity (>99 %, ITLC, HPLC) and specific activity of 1400-2100 MBq/nM at 95 °C using 40-60 μg of the peptide in 5-7 min followed by solid phase purification. The IC50 [nM] DOTA-TRP was comparable to the intact peptide, 0.11 ± 0.01 and 0.22 ± 0.05, respectively. The biodistribution of the tracer demonstrated kidney, stomach, and testes significant uptake, all in accordance with GnRH receptor ligands. Significant tumour uptake was observed in 4T1 tumour-bearing female mice 30-120 min post-injection with tumour:blood and tumour:muscle ratios of 28 and >50 in 60 min, respectively. Kidney is rapidly washed from the tracer. [(68)Ga]-DOTA-TRP can be proposed as a possible tracer for GnRH-R imaging studies.

  1. New horizons in cardiac innervation imaging: introduction of novel 18F-labeled PET tracers.

    PubMed

    Kobayashi, Ryohei; Chen, Xinyu; Werner, Rudolf A; Lapa, Constantin; Javadi, Mehrbod S; Higuchi, Takahiro

    2017-12-01

    Cardiac sympathetic nervous activity can be uniquely visualized by non-invasive radionuclide imaging techniques due to the fast growing and widespread application of nuclear cardiology in the last few years. The norepinephrine analogue 123 I-meta-iodobenzylguanidine ( 123 I-MIBG) is a single photon emission computed tomography (SPECT) tracer for the clinical implementation of sympathetic nervous imaging for both diagnosis and prognosis of heart failure. Meanwhile, positron emission tomography (PET) imaging has become increasingly attractive because of its higher spatial and temporal resolution compared to SPECT, which allows regional functional and dynamic kinetic analysis. Nevertheless, wider use of cardiac sympathetic nervous PET imaging is still limited mainly due to the demand of costly on-site cyclotrons, which are required for the production of conventional 11 C-labeled (radiological half-life, 20 min) PET tracers. Most recently, more promising 18 F-labeled (half-life, 110 min) PET radiopharmaceuticals targeting sympathetic nervous system have been introduced. These tracers optimize PET imaging and, by using delivery networks, cost less to produce. In this article, the latest advances of sympathetic nervous imaging using 18 F-labeled radiotracers along with their possible applications are reviewed.

  2. Pareto Tracer: a predictor-corrector method for multi-objective optimization problems

    NASA Astrophysics Data System (ADS)

    Martín, Adanay; Schütze, Oliver

    2018-03-01

    This article proposes a novel predictor-corrector (PC) method for the numerical treatment of multi-objective optimization problems (MOPs). The algorithm, Pareto Tracer (PT), is capable of performing a continuation along the set of (local) solutions of a given MOP with k objectives, and can cope with equality and box constraints. Additionally, the first steps towards a method that manages general inequality constraints are also introduced. The properties of PT are first discussed theoretically and later numerically on several examples.

  3. Environmentally safe areas and routes in the Baltic proper using Eulerian tracers.

    PubMed

    Höglund, A; Meier, H E M

    2012-07-01

    In recent years, the shipping of environmentally hazardous cargo has increased considerably in the Baltic proper. In this study, a large number of hypothetical oil spills with an idealized, passive tracer are simulated. From the tracer distributions, statistical measures are calculated to optimize the quantity of tracer from a spill that would stay at sea as long as possible. Increased time may permit action to be taken against the spill before the oil reaches environmentally vulnerable coastal zones. The statistical measures are used to calculate maritime routes with maximum probability that an oil spill will stay at sea as long as possible. Under these assumptions, ships should follow routes that are located south of Bornholm instead of the northern routes in use currently. Our results suggest that the location of the optimal maritime routes depends on the season, although interannual variability is too large to identify statistically significant changes. Copyright © 2012. Published by Elsevier Ltd.

  4. Predictive value of tracer studies for /sup 131/I treatment in hyperthyroid cats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broome, M.R.; Turrel, J.M.; Hays, M.T.

    In 76 cats with hyperthyroidism, peak thyroidal radioiodine (/sup 131/I) uptakes and effective half-lives were determined after administration of tracer and therapeutic activities of /sup 131/I. In 6 additional hyperthyroid cats, only peak thyroidal uptakes after administration of tracer and therapeutic activities of /sup 131/I were determined. Good correlation was found between peak thyroidal uptakes of tracer and therapeutic /sup 131/I; however, only fair correlation was observed between effective half-lives. In 79% of the cats, the effective half-life for therapeutic /sup 131/I was longer than that for tracer /sup 131/I. After administration of therapeutic activity of /sup 131/I, monoexponential andmore » biphasic decay curves were observed in 51 and 16 cats, respectively. Using therapeutic kinetic data, radiation doses to the thyroid gland were calculated retrospectively on the basis of 2 methods for determining the activity of /sup 131/I administered: (1) actual administration of tracer-compensated activity and (2) hypothetic administration of uniform activity (3 mCi). Because of the good predictive ability of tracer kinetic data for the therapeutic kinetic data, the tracer-compensated radiation doses came significantly (P = 0.008) closer to the therapeutic goal than did the uniform-activity doses. In addition, the use of tracer kinetic information reduced the extent of the tendency for consistently high uniform-activity doses. A manual method for acquiring tracer kinetic data was developed and was an acceptable alternative to computerized techniques. Adoption of this method gives individuals and institutions with limited finances the opportunity to characterize the iodine kinetics in cats before proceeding with administration of therapeutic activities of /sup 131/I.« less

  5. Human biokinetic data and a new compartmental model of zirconium--a tracer study with enriched stable isotopes.

    PubMed

    Greiter, Matthias B; Giussani, Augusto; Höllriegl, Vera; Li, Wei Bo; Oeh, Uwe

    2011-09-01

    Biokinetic models describing the uptake, distribution and excretion of trace elements are an essential tool in nutrition, toxicology, or internal dosimetry of radionuclides. Zirconium, especially its radioisotope (95)Zr, is relevant to radiation protection due to its production in uranium fission and neutron activation of nuclear fuel cladding material. We present a comprehensive set of human data from a tracer study with stable isotopes of zirconium. The data are used to refine a biokinetic model of zirconium. Six female and seven male healthy adult volunteers participated in the study. It includes 16 complete double tracer investigations with oral ingestion and intravenous injection, and seven supplemental investigations. Tracer concentrations were measured in blood plasma and urine collected up to 100 d after tracer administration. The four data sets (two chemical tracer forms in plasma and urine) each encompass 105-240 measured concentration values above detection limits. Total fractional absorption of ingested zirconium was found to be 0.001 for zirconium in citrate-buffered drinking solution and 0.007 for zirconium oxalate solution. Biokinetic models were developed based on the linear first-order kinetic compartmental model approach used by the International Commission on Radiological Protection (ICRP). The main differences of the optimized systemic model of zirconium to the current ICRP model are (1) recycling into the transfer compartment made necessary by the observed tracer clearance from plasma, (2) different parameters related to fractional absorption for each form of the ingested tracer, and (3) a physiologically based excretion pathway to urine. The study considerably expands the knowledge on the biokinetics of zirconium, which was until now dominated by data from animal studies. The proposed systemic model improves the existing ICRP model, yet is based on the same principles and fits well into the ICRP radiation protection approach. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Diffusion-limited mixing by incompressible flows

    NASA Astrophysics Data System (ADS)

    Miles, Christopher J.; Doering, Charles R.

    2018-05-01

    Incompressible flows can be effective mixers by appropriately advecting a passive tracer to produce small filamentation length scales. In addition, diffusion is generally perceived as beneficial to mixing due to its ability to homogenize a passive tracer. However we provide numerical evidence that, in cases where advection and diffusion are both actively present, diffusion may produce negative effects by limiting the mixing effectiveness of incompressible optimal flows. This limitation appears to be due to the presence of a limiting length scale given by a generalised Batchelor length (Batchelor 1959 J. Fluid Mech. 5 113–33). This length scale limitation may in turn affect long-term mixing rates. More specifically, we consider local-in-time flow optimisation under energy and enstrophy flow constraints with the objective of maximising the mixing rate. We observe that, for enstrophy-bounded optimal flows, the strength of diffusion may not impact the long-term mixing rate. For energy-constrained optimal flows, however, an increase in the strength of diffusion can decrease the mixing rate. We provide analytical lower bounds on mixing rates and length scales achievable under related constraints (point-wise bounded speed and rate-of-strain) by extending the work of Lin et al (2011 J. Fluid Mech. 675 465–76) and Poon (1996 Commun. PDE 21 521–39).

  7. Methodology for quantitative rapid multi-tracer PET tumor characterizations.

    PubMed

    Kadrmas, Dan J; Hoffman, John M

    2013-10-04

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted.

  8. Methodology for Quantitative Rapid Multi-Tracer PET Tumor Characterizations

    PubMed Central

    Kadrmas, Dan J.; Hoffman, John M.

    2013-01-01

    Positron emission tomography (PET) can image a wide variety of functional and physiological parameters in vivo using different radiotracers. As more is learned about the molecular basis for disease and treatment, the potential value of molecular imaging for characterizing and monitoring disease status has increased. Characterizing multiple aspects of tumor physiology by imaging multiple PET tracers in a single patient provides additional complementary information, and there is a significant body of literature supporting the potential value of multi-tracer PET imaging in oncology. However, imaging multiple PET tracers in a single patient presents a number of challenges. A number of techniques are under development for rapidly imaging multiple PET tracers in a single scan, where signal-recovery processing algorithms are employed to recover various imaging endpoints for each tracer. Dynamic imaging is generally used with tracer injections staggered in time, and kinetic constraints are utilized to estimate each tracers' contribution to the multi-tracer imaging signal. This article summarizes past and ongoing work in multi-tracer PET tumor imaging, and then organizes and describes the main algorithmic approaches for achieving multi-tracer PET signal-recovery. While significant advances have been made, the complexity of the approach necessitates protocol design, optimization, and testing for each particular tracer combination and application. Rapid multi-tracer PET techniques have great potential for both research and clinical cancer imaging applications, and continued research in this area is warranted. PMID:24312149

  9. Comparison of dual-biomarker PIB-PET and dual-tracer PET in AD diagnosis.

    PubMed

    Fu, Liping; Liu, Linwen; Zhang, Jinming; Xu, Baixuan; Fan, Yong; Tian, Jiahe

    2014-11-01

    To identify the optimal time window for capturing perfusion information from early (11)C-PIB imaging frames (perfusion PIB, (11)C-pPIB) and to compare the performance of (18)F-FDG PET and "dual biomarker" (11)C-PIB PET [(11)C-pPIB and amyloid PIB ((11)C-aPIB)] for classification of AD, MCI and CN subjects. Forty subjects (14 CN, 12 MCI and 14 AD patients) underwent (18)F-FDG and (11)C-PIB PET studies. Pearson correlation between the (18)F-FDG image and sum of early (11)C-PIB frames was maximised to identify the optimal time window for (11)C-pPIB. The classification power of imaging parameters was evaluated with a leave-one-out validation. A 7-min time window yielded the highest correlation between (18)F-FDG and (11)C-pPIB. (11)C-pPIB and (18)F-FDG images shared a similar radioactive distribution pattern. (18)F-FDG performed better than (11)C-pPIB for the classification of both AD vs. CN and MCI vs. CN. (11)C-pPIB + (11)C-aPIB and (18)F-FDG + (11)C-aPIB yielded the highest classification accuracy for the classification of AD vs. CN, and (18)F-FDG + (11)C-aPIB had the best classification performance for the classification of MCI vs. C-pPIB could serve as a useful biomarker of rCBF for measuring neural activity and improve the diagnostic power of PET for AD in conjunction with (11)C-aPIB. (18)F-FDG and (11)C-PIB dual-tracer PET examination could better detect MCI. • Dual-tracer PET examination provides neurofunctional and neuropathological information for AD diagnosis. • The identified optimal 11C-pPIB time frames had highest correlation with 18F-FDG. • 11C-pPIB images shared a similar radioactive distribution pattern with 18F-FDG images. • 11C-pPIB can provide neurofunctional information. • Dual-tracer PET examination could better detect MCI.

  10. SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site.

    PubMed

    Hirschmann, Michael T; Mathis, Dominic; Rasch, Helmut; Amsler, Felix; Friederich, Niklaus F; Arnold, Markus P

    2013-02-01

    SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. A consecutive series of knees (n=66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientation.

  11. Radiolabeling optimization and characterization of (68)Ga labeled DOTA-polyamido-amine dendrimer conjugate - Animal biodistribution and PET imaging results.

    PubMed

    Ghai, Aanchal; Singh, Baljinder; Panwar Hazari, Puja; Schultz, Michael K; Parmar, Ambika; Kumar, Pardeep; Sharma, Sarika; Dhawan, Devinder; Kumar Mishra, Anil

    2015-11-01

    The present study describes the optimization of (68)Ga radiolabeling with PAMAM dendrimer-DOTA conjugate. A conjugate (PAMAM-DOTA) concentration of 11.69µM, provided best radiolabeling efficiency of more than 93.0% at pH 4.0, incubation time of 30.0min and reaction temperature ranging between 90 and 100°C. The decay corrected radiochemical yield was found to be 79.4±0.01%. The radiolabeled preparation ([(68)Ga]-DOTA-PAMAM-D) remained stable (radiolabeling efficiency of 96.0%) at room temperature and in serum for up to 4-h. The plasma protein binding was observed to be 21.0%. After intravenous administration, 50.0% of the tracer cleared from the blood circulation by 30-min and less than 1.0% of the injected activity remained in blood by 1.0h. The animal biodistribution studies demonstrated that the tracer excretes through the kidneys and about 0.33% of the %ID/g accumulated in the tumor at 1h post injection. The animal organ's biodistribution data was supported by animal PET imaging showing good 'non-specific' tracer uptake in tumor and excretion is primarily through kidneys. Additionally, DOTA-PAMAM-D conjugation with αVβ3 receptors targeting peptides and drug loading on the dendrimers may improve the specificity of the (68)Ga labeled product for imaging and treating angiogenesis respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  13. Parameters optimization defined by statistical analysis for cysteine-dextran radiolabeling with technetium tricarbonyl core.

    PubMed

    Núñez, Eutimio Gustavo Fernández; Faintuch, Bluma Linkowski; Teodoro, Rodrigo; Wiecek, Danielle Pereira; da Silva, Natanael Gomes; Papadopoulos, Minas; Pelecanou, Maria; Pirmettis, Ioannis; de Oliveira Filho, Renato Santos; Duatti, Adriano; Pasqualini, Roberto

    2011-04-01

    The objective of this study was the development of a statistical approach for radiolabeling optimization of cysteine-dextran conjugates with Tc-99m tricarbonyl core. This strategy has been applied to the labeling of 2-propylene-S-cysteine-dextran in the attempt to prepare a new class of tracers for sentinel lymph node detection, and can be extended to other radiopharmaceuticals for different targets. The statistical routine was based on three-level factorial design. Best labeling conditions were achieved. The specific activity reached was 5 MBq/μg. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  14. Biological tracer method

    DOEpatents

    Strong-Gunderson, Janet M.; Palumbo, Anthony V.

    1998-01-01

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer.

  15. Biological tracer method

    DOEpatents

    Strong-Gunderson, J.M.; Palumbo, A.V.

    1998-09-15

    The present invention is a biological tracer method for characterizing the movement of a material through a medium, comprising the steps of: introducing a biological tracer comprising a microorganism having ice nucleating activity into a medium; collecting at least one sample of the medium from a point removed from the introduction point; and analyzing the sample for the presence of the biological tracer. The present invention is also a method for using a biological tracer as a label for material identification by introducing a biological tracer having ice nucleating activity into a material, collecting a sample of a portion of the labelled material and analyzing the sample for the presence of the biological tracer. 2 figs.

  16. A novel fluorine-18 β-fluoroethoxy organophosphate positron emission tomography imaging tracer targeted to central nervous system acetylcholinesterase.

    PubMed

    James, Shelly L; Ahmed, S Kaleem; Murphy, Stephanie; Braden, Michael R; Belabassi, Yamina; VanBrocklin, Henry F; Thompson, Charles M; Gerdes, John M

    2014-07-16

    Radiosynthesis of a fluorine-18 labeled organophosphate (OP) inhibitor of acetylcholinesterase (AChE) and subsequent positron emission tomography (PET) imaging using the tracer in the rat central nervous system are reported. The tracer structure, which contains a novel β-fluoroethoxy phosphoester moiety, was designed as an insecticide-chemical nerve agent hybrid to optimize handling and the desired target reactivity. Radiosynthesis of the β-fluoroethoxy tracer is described that utilizes a [(18)F]prosthetic group coupling approach. The imaging utility of the [(18)F]tracer is demonstrated in vivo within rats by the evaluation of its brain penetration and cerebral distribution qualities in the absence and presence of a challenge agent. The tracer effectively penetrates brain and localizes to cerebral regions known to correlate with the expression of the AChE target. Brain pharmacokinetic properties of the tracer are consistent with the formation of an OP-adducted acetylcholinesterase containing the fluoroethoxy tracer group. Based on the initial favorable in vivo qualities found in rat, additional [(18)F]tracer studies are ongoing to exploit the technology to dynamically probe organophosphate mechanisms of action in mammalian live tissues.

  17. Preclinical Evaluation of RYM1, a Matrix Metalloproteinase-Targeted Tracer for Imaging Aneurysm.

    PubMed

    Toczek, Jakub; Ye, Yunpeng; Gona, Kiran; Kim, Hye-Yeong; Han, Jinah; Razavian, Mahmoud; Golestani, Reza; Zhang, Jiasheng; Wu, Terence L; Jung, Jae-Joon; Sadeghi, Mehran M

    2017-08-01

    Matrix metalloproteinases (MMPs) play a key role in abdominal aortic aneurysm (AAA) development. Accordingly, MMP-targeted imaging provides important information regarding vessel wall biology in the course of aneurysm development. Given the small size of the vessel wall and its proximity with blood, molecular imaging of aneurysm optimally requires highly sensitive tracers with rapid blood clearance. To this end, we developed a novel hydrosoluble zwitterionic MMP inhibitor, RYM, on the basis of which a pan-MMP tracer, RYM1, was designed. Here, we describe the development and preclinical evaluation of RYM1 in comparison with RP805, a commonly used pan-MMP tracer in murine models of aneurysm. Methods: The macrocyclic hydroxamate-based pan-MMP inhibitor coupled with 6-hydrazinonicotinamide, RYM1, was synthesized and labeled with 99m Tc. Radiochemical stability of 99m Tc-RYM1 was evaluated by radio-high-performance liquid chromatography analysis. Tracer blood kinetics and biodistribution were compared with 99m Tc-RP805 in C57BL/6J mice ( n = 10). 99m Tc-RYM1 binding to aneurysm and specificity were evaluated by quantitative autoradiography in apolipoprotein E-deficient (apoE -/- ) mice with CaCl 2 -induced carotid aneurysm ( n = 11). Angiotensin II-infused apoE -/- ( n = 16) mice were used for small-animal SPECT/CT imaging. Aortic tissue MMP activity and macrophage marker CD68 expression were assessed by zymography and reverse-transcription polymerase chain reaction. Results: RYM1 showed nanomolar range inhibition constants for several MMPs. 99m Tc-RYM1 was radiochemically stable in mouse blood for 5 h and demonstrated rapid renal clearance and lower blood levels in vivo compared with 99m Tc-RP805. 99m Tc-RYM1 binding to aneurysm and its specificity were shown by autoradiography in carotid aneurysm. Angiotensin II infusion in apoE -/- mice for 4 wk resulted in AAA formation in 36% (4/11) of surviving animals. In vivo 99m Tc-RYM1 small-animal SPECT/CT images showed higher uptake of the tracer in AAA than nondilated aortae. Finally, aortic uptake of 99m Tc-RYM1 in vivo correlated with aortic MMP activity and CD68 expression. Conclusion: The newly developed pan-MMP inhibitor-based tracer 99m Tc-RYM1 displays favorable pharmacokinetics for early vascular imaging and enables specific detection of inflammation and MMP activity in aneurysm. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Many-objective Groundwater Monitoring Network Design Using Bias-Aware Ensemble Kalman Filtering and Evolutionary Optimization

    NASA Astrophysics Data System (ADS)

    Kollat, J. B.; Reed, P. M.

    2009-12-01

    This study contributes the ASSIST (Adaptive Strategies for Sampling in Space and Time) framework for improving long-term groundwater monitoring decisions across space and time while accounting for the influences of systematic model errors (or predictive bias). The ASSIST framework combines contaminant flow-and-transport modeling, bias-aware ensemble Kalman filtering (EnKF) and many-objective evolutionary optimization. Our goal in this work is to provide decision makers with a fuller understanding of the information tradeoffs they must confront when performing long-term groundwater monitoring network design. Our many-objective analysis considers up to 6 design objectives simultaneously and consequently synthesizes prior monitoring network design methodologies into a single, flexible framework. This study demonstrates the ASSIST framework using a tracer study conducted within a physical aquifer transport experimental tank located at the University of Vermont. The tank tracer experiment was extensively sampled to provide high resolution estimates of tracer plume behavior. The simulation component of the ASSIST framework consists of stochastic ensemble flow-and-transport predictions using ParFlow coupled with the Lagrangian SLIM transport model. The ParFlow and SLIM ensemble predictions are conditioned with tracer observations using a bias-aware EnKF. The EnKF allows decision makers to enhance plume transport predictions in space and time in the presence of uncertain and biased model predictions by conditioning them on uncertain measurement data. In this initial demonstration, the position and frequency of sampling were optimized to: (i) minimize monitoring cost, (ii) maximize information provided to the EnKF, (iii) minimize failure to detect the tracer, (iv) maximize the detection of tracer flux, (v) minimize error in quantifying tracer mass, and (vi) minimize error in quantifying the moment of the tracer plume. The results demonstrate that the many-objective problem formulation provides a tremendous amount of information for decision makers. Specifically our many-objective analysis highlights the limitations and potentially negative design consequences of traditional single and two-objective problem formulations. These consequences become apparent through visual exploration of high-dimensional tradeoffs and the identification of regions with interesting compromise solutions. The prediction characteristics of these compromise designs are explored in detail, as well as their implications for subsequent design decisions in both space and time.

  19. A strategy to measure electrophysiological changes with photoacoustic imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sepela, Rebecka J.; Sherlock, Benjamin E.; Tian, Lin; Marcu, Laura; Sack, Jon

    2017-03-01

    Photoacoustic imaging is an emerging technology capable of both functional and structural biological imaging. Absorption and scattering in tissue limit the penetration depth of conventional microscopy techniques to <1mm. Photoacoustic imaging however, can offer high-resolution and contrast at depths of several centimeters. Though functional imaging of endogenous contrast agents, such as hemoglobin, is widely implemented, currently photoacoustic imaging is unable to functionally report electrophysiological changes within cells. We aim to develop photoacoustic contrast agents to fulfill this need. Cells throughout the brain and body create electrical signals using ion channel proteins. These proteins undergo structural changes to regulate the flux of salt ions into the cell. We have recently developed ion channel activity tracers that dissociate from ion channels after the protein changes structure. By conjugating the tracer to dyes that are sensitive to changes in their chemical environment, we can detect tracer dissociation and therefore ion channel activity. We are exploring whether a similar mechanism can create photoacoustic signal intensity changes. To test if the environmental sensitivity of the dye is photoacoustically distinguishable, we imaged the dye in different solvent backgrounds. We report that manipulation of the chemical environment of the contrast dye results in robust changes in photoacoustic properties. We are working to capture photoacoustic signal changes that occur when ion channel proteins activate using live cell imaging. This technology could permit photoacoustic imaging of electrophysiological dynamics in deep tissue, such as the brain. Further optimization of this technology could lead to concurrent imaging of neural activity and hemodynamic responses, a crucial step towards understanding neurovascular coupling in the brain.

  20. Feasibility of Rapid Multitracer PET Tumor Imaging

    NASA Astrophysics Data System (ADS)

    Kadrmas, D. J.; Rust, T. C.

    2005-10-01

    Positron emission tomography (PET) can characterize different aspects of tumor physiology using various tracers. PET scans are usually performed using only one tracer since there is no explicit signal for distinguishing multiple tracers. We tested the feasibility of rapidly imaging multiple PET tracers using dynamic imaging techniques, where the signals from each tracer are separated based upon differences in tracer half-life, kinetics, and distribution. Time-activity curve populations for FDG, acetate, ATSM, and PTSM were simulated using appropriate compartment models, and noisy dual-tracer curves were computed by shifting and adding the single-tracer curves. Single-tracer components were then estimated from dual-tracer data using two methods: principal component analysis (PCA)-based fits of single-tracer components to multitracer data, and parallel multitracer compartment models estimating single-tracer rate parameters from multitracer time-activity curves. The PCA analysis found that there is information content present for separating multitracer data, and that tracer separability depends upon tracer kinetics, injection order and timing. Multitracer compartment modeling recovered rate parameters for individual tracers with good accuracy but somewhat higher statistical uncertainty than single-tracer results when the injection delay was >10 min. These approaches to processing rapid multitracer PET data may potentially provide a new tool for characterizing multiple aspects of tumor physiology in vivo.

  1. Optimal galaxy survey for detecting the dipole in the cross-correlation with 21 cm Intensity Mapping

    NASA Astrophysics Data System (ADS)

    Lepori, Francesca; Di Dio, Enea; Villa, Eleonora; Viel, Matteo

    2018-05-01

    We investigate the future perspectives of the detection of the relativistic dipole by cross-correlating the 21 cm emission in Intensity Mapping (IM) and galaxy surveys at low redshift. We model the neutral hydrogen (HI) and the galaxy population by means of the halo model to relate the parameters that affect the dipole signal such as the biases of the two tracers and the Poissonian noise. We investigate the behavior of the signal-to-noise as a function of the galaxy and magnification biases, for two fixed models of the neutral hydrogen. In both cases we found that the signal-to-noise does not grow by increasing the difference between the biases of the two tracers, due to the larger shot-noise yields by highly biased tracers. We also study and provide an optimal luminosity-threshold galaxy catalogue to enhance the signal-to-noise ratio of the relativistic dipole. Interestingly, we show that the maximum magnitude provided by the survey does not lead to the maximum signal-to-noise for detecting relativistic effects and we predict the optimal value for the limiting magnitude. Our work suggests that an optimal analysis could increase the signal-to-noise ratio up to a factor five compared to a standard one.

  2. Selective Imaging of VEGFR-1 and VEGFR-2 Using 89Zr-Labeled Single-Chain VEGF Mutants.

    PubMed

    Meyer, Jan-Philip; Edwards, Kimberly J; Kozlowski, Paul; Backer, Marina V; Backer, Joseph M; Lewis, Jason S

    2016-11-01

    Vascular endothelial growth factor-A (VEGF-A) acts via 2 vascular endothelial growth factor receptors, VEGFR-1 and VEGFR-2, that play important and distinct roles in tumor biology. We reasoned that selective imaging of these receptors could provide unique information for diagnostics and for monitoring and optimizing responses to anticancer therapy, including antiangiogenic therapy. Herein, we report the development of 2 first-in-class 89 Zr-labeled PET tracers that enable the selective imaging of VEGFR-1 and VEGFR-2. Functionally active mutants of scVEGF (an engineered single-chain version of pan-receptor VEGF-A with an N-terminal cysteine-containing tag for site-specific conjugation), named scVR1 and scVR2 with enhanced affinity to, respectively, VEGFR-1 and VEGFR-2, were constructed. Parental scVEGF and its receptor-specific mutants were site-specifically derivatized with the 89 Zr chelator desferroxamine B via a 3.4-kDa PEG linker. 89 Zr labeling of the desferroxamine B conjugates furnished scV/Zr, scVR1/Zr, and scVR2/Zr tracers with high radiochemical yield (>87%), high specific activity (≥9.8 MBq/nmol), and purity (>99%). Tracers were tested in an orthotopic breast cancer model using 4T1luc-bearing syngeneic BALB/c mice. For testing tracer specificity, tracers were coinjected with an excess of cold proteins of the same or opposite receptor specificity or pan-receptor scVEGF. PET imaging, biodistribution, and dosimetry studies in mice, as well as immunohistochemical analysis of harvested tumors, were performed. All tracers rapidly accumulated in orthotopic 4T1luc tumors, allowing for the successful PET imaging of the tumors as early as 2 h after injection. Blocking experiments with an excess of pan-receptor or receptor-specific cold proteins indicated that more than 80% of tracer tumor uptake is VEGFR-mediated, whereas uptake in all major organs is not affected by blocking within the margin of error. Critically, blocking experiments indicated that VEGFR-mediated tumor uptake of scVR1/Zr and scVR2/Zr was mediated exclusively by the corresponding receptor, VEGFR-1 or VEGFR-2, respectively. In contrast, uptake of pan-receptor scV/Zr was mediated by both VEGFR-1 and VEGFR-2 at an approximately 2:1 ratio. First-in-class selective PET tracers for imaging VEGFR-1 and VEGFR-2 were constructed and successfully validated in an orthotopic murine tumor model. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. Borehole flowmeter logging for the accurate design and analysis of tracer tests.

    PubMed

    Basiricò, Stefano; Crosta, Giovanni B; Frattini, Paolo; Villa, Alberto; Godio, Alberto

    2015-04-01

    Tracer tests often give ambiguous interpretations that may be due to the erroneous location of sampling points and/or the lack of flow rate measurements through the sampler. To obtain more reliable tracer test results, we propose a methodology that optimizes the design and analysis of tracer tests in a cross borehole mode by using vertical borehole flow rate measurements. Experiments using this approach, herein defined as the Bh-flow tracer test, have been performed by implementing three sequential steps: (1) single-hole flowmeter test, (2) cross-hole flowmeter test, and (3) tracer test. At the experimental site, core logging, pumping tests, and static water-level measurements were previously carried out to determine stratigraphy, fracture characteristics, and bulk hydraulic conductivity. Single-hole flowmeter testing makes it possible to detect the presence of vertical flows as well as inflow and outflow zones, whereas cross-hole flowmeter testing detects the presence of connections along sets of flow conduits or discontinuities intercepted by boreholes. Finally, the specific pathways and rates of groundwater flow through selected flowpaths are determined by tracer testing. We conclude that the combined use of single and cross-borehole flowmeter tests is fundamental to the formulation of the tracer test strategy and interpretation of the tracer test results. © 2014, National Ground Water Association.

  4. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    NASA Astrophysics Data System (ADS)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against laboratory data and then we attempt to use the validated model to describe the tracer long-term slowdown.

  5. AN INTEGRATED APPROACH TO CHARACTERIZING BYPASSED OIL IN HETEROGENEOUS AND FRACTURED RESERVOIRS USING PARTITIONING TRACERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhil Datta-Gupta

    2003-08-01

    We explore the use of efficient streamline-based simulation approaches for modeling partitioning interwell tracer tests in hydrocarbon reservoirs. Specifically, we utilize the unique features of streamline models to develop an efficient approach for interpretation and history matching of field tracer response. A critical aspect here is the underdetermined and highly ill-posed nature of the associated inverse problems. We have adopted an integrated approach whereby we combine data from multiple sources to minimize the uncertainty and non-uniqueness in the interpreted results. For partitioning interwell tracer tests, these are primarily the distribution of reservoir permeability and oil saturation distribution. A novel approachmore » to multiscale data integration using Markov Random Fields (MRF) has been developed to integrate static data sources from the reservoir such as core, well log and 3-D seismic data. We have also explored the use of a finite difference reservoir simulator, UTCHEM, for field-scale design and optimization of partitioning interwell tracer tests. The finite-difference model allows us to include detailed physics associated with reactive tracer transport, particularly those related with transverse and cross-streamline mechanisms. We have investigated the potential use of downhole tracer samplers and also the use of natural tracers for the design of partitioning tracer tests. Finally, the behavior of partitioning tracer tests in fractured reservoirs is investigated using a dual-porosity finite-difference model.« less

  6. Multi-objective experimental design for (13)C-based metabolic flux analysis.

    PubMed

    Bouvin, Jeroen; Cajot, Simon; D'Huys, Pieter-Jan; Ampofo-Asiama, Jerry; Anné, Jozef; Van Impe, Jan; Geeraerd, Annemie; Bernaerts, Kristel

    2015-10-01

    (13)C-based metabolic flux analysis is an excellent technique to resolve fluxes in the central carbon metabolism but costs can be significant when using specialized tracers. This work presents a framework for cost-effective design of (13)C-tracer experiments, illustrated on two different networks. Linear and non-linear optimal input mixtures are computed for networks for Streptomyces lividans and a carcinoma cell line. If only glucose tracers are considered as labeled substrate for a carcinoma cell line or S. lividans, the best parameter estimation accuracy is obtained by mixtures containing high amounts of 1,2-(13)C2 glucose combined with uniformly labeled glucose. Experimental designs are evaluated based on a linear (D-criterion) and non-linear approach (S-criterion). Both approaches generate almost the same input mixture, however, the linear approach is favored due to its low computational effort. The high amount of 1,2-(13)C2 glucose in the optimal designs coincides with a high experimental cost, which is further enhanced when labeling is introduced in glutamine and aspartate tracers. Multi-objective optimization gives the possibility to assess experimental quality and cost at the same time and can reveal excellent compromise experiments. For example, the combination of 100% 1,2-(13)C2 glucose with 100% position one labeled glutamine and the combination of 100% 1,2-(13)C2 glucose with 100% uniformly labeled glutamine perform equally well for the carcinoma cell line, but the first mixture offers a decrease in cost of $ 120 per ml-scale cell culture experiment. We demonstrated the validity of a multi-objective linear approach to perform optimal experimental designs for the non-linear problem of (13)C-metabolic flux analysis. Tools and a workflow are provided to perform multi-objective design. The effortless calculation of the D-criterion can be exploited to perform high-throughput screening of possible (13)C-tracers, while the illustrated benefit of multi-objective design should stimulate its application within the field of (13)C-based metabolic flux analysis. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Glial Activation and Glucose Metabolism in a Transgenic Amyloid Mouse Model: A Triple-Tracer PET Study.

    PubMed

    Brendel, Matthias; Probst, Federico; Jaworska, Anna; Overhoff, Felix; Korzhova, Viktoria; Albert, Nathalie L; Beck, Roswitha; Lindner, Simon; Gildehaus, Franz-Josef; Baumann, Karlheinz; Bartenstein, Peter; Kleinberger, Gernot; Haass, Christian; Herms, Jochen; Rominger, Axel

    2016-06-01

    Amyloid imaging by small-animal PET in models of Alzheimer disease (AD) offers the possibility to track amyloidogenesis and brain energy metabolism. Because microglial activation is thought to contribute to AD pathology, we undertook a triple-tracer small-animal PET study to assess microglial activation and glucose metabolism in association with amyloid plaque load in a transgenic AD mouse model. Groups of PS2APP and C57BL/6 wild-type mice of various ages were examined by small-animal PET. We acquired 90-min dynamic emission data with (18)F-GE180 for imaging activated microglia (18-kD translocator protein ligand [TSPO]) and static 30- to 60-min recordings with (18)F-FDG for energy metabolism and (18)F-florbetaben for amyloidosis. Optimal fusion of PET data was obtained through automatic nonlinear spatial normalization, and SUVRs were calculated. For the novel TSPO tracer (18)F-GE180, we then calculated distribution volume ratios after establishing a suitable reference region. Immunohistochemical analyses with TSPO antisera, methoxy-X04 staining for fibrillary β-amyloid, and ex vivo autoradiography served as terminal gold standard assessments. SUVR at 60-90 min after injection gave robust quantitation of (18)F-GE180, which correlated well with distribution volume ratios calculated from the entire recording and using a white matter reference region. Relative to age-matched wild-type, (18)F-GE180 SUVR was slightly elevated in PS2APP mice at 5 mo (+9%; P < 0.01) and distinctly increased at 16 mo (+25%; P < 0.001). Over this age range, there was a high positive correlation between small-animal PET findings of microglial activation with amyloid load (R = 0.85; P < 0.001) and likewise with metabolism (R = 0.61; P < 0.005). Immunohistochemical and autoradiographic findings confirmed the in vivo small-animal PET data. In this first triple-tracer small-animal PET in a well-established AD mouse model, we found evidence for age-dependent microglial activation. This activation, correlating positively with the amyloid load, implies a relationship between amyloidosis and inflammation in the PS2APP AD mouse model. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  8. Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization

    PubMed Central

    Bauer, L. M.; Hensley, D. W.; Zheng, B.; Tay, Z. W.; Goodwill, P. W.; Griswold, M. A.; Conolly, S. M.

    2016-01-01

    The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room. PMID:27250472

  9. Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization.

    PubMed

    Bauer, L M; Hensley, D W; Zheng, B; Tay, Z W; Goodwill, P W; Griswold, M A; Conolly, S M

    2016-05-01

    The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room.

  10. Comparison of Kinetic Models for Dual-Tracer Receptor Concentration Imaging in Tumors

    PubMed Central

    Hamzei, Nazanin; Samkoe, Kimberley S; Elliott, Jonathan T; Holt, Robert W; Gunn, Jason R; Hasan, Tayyaba; Pogue, Brian W; Tichauer, Kenneth M

    2014-01-01

    Molecular differences between cancerous and healthy tissue have become key targets for novel therapeutics specific to tumor receptors. However, cancer cell receptor expression can vary within and amongst different tumors, making strategies that can quantify receptor concentration in vivo critical for the progression of targeted therapies. Recently a dual-tracer imaging approach capable of providing quantitative measures of receptor concentration in vivo was developed. It relies on the simultaneous injection and imaging of receptor-targeted tracer and an untargeted tracer (to account for non-specific uptake of the targeted tracer). Early implementations of this approach have been structured on existing “reference tissue” imaging methods that have not been optimized for or validated in dual-tracer imaging. Using simulations and mouse tumor model experimental data, the salient findings in this study were that all widely used reference tissue kinetic models can be used for dual-tracer imaging, with the linearized simplified reference tissue model offering a good balance of accuracy and computational efficiency. Moreover, an alternate version of the full two-compartment reference tissue model can be employed accurately by assuming that the K1s of the targeted and untargeted tracers are similar to avoid assuming an instantaneous equilibrium between bound and free states (made by all other models). PMID:25414912

  11. Investigating the Vertical Distribution and Source Attribution of Black Carbon over the Pacific Ocean

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Liu, J.; Ban-Weiss, G. A.; Tao, S.

    2014-12-01

    Long-range transport of black carbon (BC) aerosols to the Pacific Ocean can potentially play a significant role in changing the marine climate through influences on temperature and cloud profiles and the top-of-atmosphere and surface energy balance. Therefore, quantitatively understanding sources of BC over the Pacific, particularly at different altitudes, is of great importance. In this study, we simulate the transport of thirteen continental BC tracers with a variety of e-folding aging times (few hours to 1 month) using the global chemical transport model MOZART-4. We then optimize BC aging rate according to different source regions by constraining the vertical profile of BC concentrations to the HAIPER Polo-to-Pole Observations (HIPPO). We find that for all HIPPO deployments, a shorter BC aging timescale (less than half day) for tropical and mid-latitude tracers and a longer aging timescale (2-10 days) for high-latitude tracers (except summer) in most cases significantly reduces model biases. By comparing the source-receptor relationship between the optimized BC tracers over the Pacific, we find that during 2009-2011, East Asia contributes most to the BC loading over the Northern Pacific in all seasons except summer, while South American, African and Australian tracers dominate the BC loadings over the Southern Pacific. In addition, unlike other tracers, African BC is a dominant contributor over a larger area in the free troposphere versus the boundary layer. Our findings indicate that the aging rate of BC strongly depends on source location and season, which may significantly influence the contribution of different source regions to BC forcing over the Pacific Ocean.

  12. Joint penalized-likelihood reconstruction of time-activity curves and regions-of-interest from projection data in brain PET

    NASA Astrophysics Data System (ADS)

    Krestyannikov, E.; Tohka, J.; Ruotsalainen, U.

    2008-06-01

    This paper presents a novel statistical approach for joint estimation of regions-of-interest (ROIs) and the corresponding time-activity curves (TACs) from dynamic positron emission tomography (PET) brain projection data. It is based on optimizing the joint objective function that consists of a data log-likelihood term and two penalty terms reflecting the available a priori information about the human brain anatomy. The developed local optimization strategy iteratively updates both the ROI and TAC parameters and is guaranteed to monotonically increase the objective function. The quantitative evaluation of the algorithm is performed with numerically and Monte Carlo-simulated dynamic PET brain data of the 11C-Raclopride and 18F-FDG tracers. The results demonstrate that the method outperforms the existing sequential ROI quantification approaches in terms of accuracy, and can noticeably reduce the errors in TACs arising due to the finite spatial resolution and ROI delineation.

  13. Toward optimization of imaging system and lymphatic tracer for near-infrared fluorescent sentinel lymph node mapping in breast cancer.

    PubMed

    Mieog, J Sven D; Troyan, Susan L; Hutteman, Merlijn; Donohoe, Kevin J; van der Vorst, Joost R; Stockdale, Alan; Liefers, Gerrit-Jan; Choi, Hak Soo; Gibbs-Strauss, Summer L; Putter, Hein; Gioux, Sylvain; Kuppen, Peter J K; Ashitate, Yoshitomo; Löwik, Clemens W G M; Smit, Vincent T H B M; Oketokoun, Rafiou; Ngo, Long H; van de Velde, Cornelis J H; Frangioni, John V; Vahrmeijer, Alexander L

    2011-09-01

    Near-infrared (NIR) fluorescent sentinel lymph node (SLN) mapping in breast cancer requires optimized imaging systems and lymphatic tracers. A small, portable version of the FLARE imaging system, termed Mini-FLARE, was developed for capturing color video and two semi-independent channels of NIR fluorescence (700 and 800 nm) in real time. Initial optimization of lymphatic tracer dose was performed using 35-kg Yorkshire pigs and a 6-patient pilot clinical trial. More refined optimization was performed in 24 consecutive breast cancer patients. All patients received the standard of care using (99m)Technetium-nanocolloid and patent blue. In addition, 1.6 ml of indocyanine green adsorbed to human serum albumin (ICG:HSA) was injected directly after patent blue at the same location. Patients were allocated to 1 of 8 escalating ICG:HSA concentration groups from 50 to 1000 μM. The Mini-FLARE system was positioned easily in the operating room and could be used up to 13 in. from the patient. Mini-FLARE enabled visualization of lymphatic channels and SLNs in all patients. A total of 35 SLNs (mean = 1.45, range 1-3) were detected: 35 radioactive (100%), 30 blue (86%), and 35 NIR fluorescent (100%). Contrast agent quenching at the injection site and dilution within lymphatic channels were major contributors to signal strength of the SLN. Optimal injection dose of ICG:HSA ranged between 400 and 800 μM. No adverse reactions were observed. We describe the clinical translation of a new NIR fluorescence imaging system and define the optimal ICG:HSA dose range for SLN mapping in breast cancer.

  14. 18F-FDG labeling of mesenchymal stem cells and multipotent adult progenitor cells for PET imaging: effects on ultrastructure and differentiation capacity.

    PubMed

    Wolfs, Esther; Struys, Tom; Notelaers, Tineke; Roberts, Scott J; Sohni, Abhishek; Bormans, Guy; Van Laere, Koen; Luyten, Frank P; Gheysens, Olivier; Lambrichts, Ivo; Verfaillie, Catherine M; Deroose, Christophe M

    2013-03-01

    Because of their extended differentiation capacity, stem cells have gained great interest in the field of regenerative medicine. For the development of therapeutic strategies, more knowledge on the in vivo fate of these cells has to be acquired. Therefore, stem cells can be labeled with radioactive tracer molecules such as (18)F-FDG, a positron-emitting glucose analog that is taken up and metabolically trapped by the cells. The aim of this study was to optimize the radioactive labeling of mesenchymal stem cells (MSCs) and multipotent adult progenitor cells (MAPCs) in vitro with (18)F-FDG and to investigate the potential radiotoxic effects of this labeling procedure with a range of techniques, including transmission electron microscopy (TEM). Mouse MSCs and rat MAPCs were used for (18)F-FDG uptake kinetics and tracer retention studies. Cell metabolic activity, proliferation, differentiation and ultrastructural changes after labeling were evaluated using an Alamar Blue reagent, doubling time calculations and quantitative TEM, respectively. Additionally, mice were injected with MSCs and MAPCs prelabeled with (18)F-FDG, and stem cell biodistribution was investigated using small-animal PET. The optimal incubation period for (18)F-FDG uptake was 60 min. Significant early tracer washout was observed, with approximately 30%-40% of the tracer being retained inside the cells 3 h after labeling. Cell viability, proliferation, and differentiation capacity were not severely affected by (18)F-FDG labeling. No major changes at the ultrastructural level, considering mitochondrial length, lysosome size, the number of lysosomes, the number of vacuoles, and the average rough endoplasmic reticulum width, were observed with TEM. Small-animal PET experiments with radiolabeled MAPCs and MSCs injected intravenously in mice showed a predominant accumulation in the lungs and a substantial elution of (18)F-FDG from the cells. MSCs and MAPCs can be successfully labeled with (18)F-FDG for molecular imaging purposes. The main cellular properties are not rigorously affected. TEM confirmed that the cells' ultrastructural properties are not influenced by (18)F-FDG labeling. Small-animal PET studies confirmed the intracellular location of the tracer and the possibility of imaging injected prelabeled stem cell types in vivo. Therefore, direct labeling of MSCs and MAPCs with (18)F-FDG is a suitable technique to noninvasively assess cell delivery and early retention with PET.

  15. River velocities from sequential multispectral remote sensing images

    NASA Astrophysics Data System (ADS)

    Chen, Wei; Mied, Richard P.

    2013-06-01

    We address the problem of extracting surface velocities from a pair of multispectral remote sensing images over rivers using a new nonlinear multiple-tracer form of the global optimal solution (GOS). The derived velocity field is a valid solution across the image domain to the nonlinear system of equations obtained by minimizing a cost function inferred from the conservation constraint equations for multiple tracers. This is done by deriving an iteration equation for the velocity, based on the multiple-tracer displaced frame difference equations, and a local approximation to the velocity field. The number of velocity equations is greater than the number of velocity components, and thus overly constrain the solution. The iterative technique uses Gauss-Newton and Levenberg-Marquardt methods and our own algorithm of the progressive relaxation of the over-constraint. We demonstrate the nonlinear multiple-tracer GOS technique with sequential multispectral Landsat and ASTER images over a portion of the Potomac River in MD/VA, and derive a dense field of accurate velocity vectors. We compare the GOS river velocities with those from over 12 years of data at four NOAA reference stations, and find good agreement. We discuss how to find the appropriate spatial and temporal resolutions to allow optimization of the technique for specific rivers.

  16. Comparison of oral iodine-131-cellulose and indium-111-DTPA as tracers for colon transit scintigraphy: Analysis by colon activity profiles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smart, R.C.; McLean, R.G.; Gaston-Parry, D.

    1991-09-01

    In 11 normal subjects and 11 patients with a clinical diagnosis of constipation, oral 131I-cellulose and 111In-DTPA were compared simultaneously as tracers for radionuclide colon transit scintigraphy. Visual assessment of the images revealed no differences between tracers. Quantitation was performed using total and segmental percent retention and the derived value of clearance half-time. In addition, profiles of the activity distribution along the length of the colon were generated and the mean position of the activity in the colon calculated. For all indices, the results were similar in both normal subjects and constipated patients when comparing tracers, although marked differences weremore » present between normal subjects and constipated patients for each tracer. Indium-111-DTPA was easy to administer and dosimetry was more acceptable than for 131I-cellulose, especially in constipated patients. It is concluded that 111In-DTPA is the preferred tracer for oral colon transit scintigraphy.« less

  17. Modification of Rhodamine WT tracer tests procedure in activated sludge reactors

    NASA Astrophysics Data System (ADS)

    Knap, Marta; Balbierz, Piotr

    2017-11-01

    One of the tracers recommended for use in wastewater treatment plants and natural waters is Rhodamine WT, which is a fluorescent dye, allowing to work at low concentrations, but may be susceptible to sorption to activated sludge flocs and chemical quenching of fluorescence by dissolved water constituents. Additionally raw sewage may contain other natural materials or pollutants exhibiting limited fluorescent properties, which are responsible for background fluorescence interference. This paper presents the proposed modifications to the Rhodamine WT tracer tests procedure in activated sludge reactors, which allow to reduce problems with background fluorescence and tracer loss over time, developed on the basis of conducted laboratory and field experiments.

  18. Development and optimization of a fluorescence polarization immunoassay for orbifloxacin in milk

    USDA-ARS?s Scientific Manuscript database

    A homogeneous microplate-based fluorescence polarization immunoassay (FPIA) for determination of orbifloxacin (ORB) in milk was developed and optimized. A monoclonal antibody of ORB was prepared, and six fluorescent tracers were synthesized from ORB and lomefloxacin (LOM) using three derivatives of...

  19. Slew-rate dependence of tracer magnetization response in magnetic particle imaging.

    PubMed

    Shah, Saqlain A; Ferguson, R M; Krishnan, K M

    2014-10-28

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ 0 excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude ( H o ) and frequency ( ω ). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particle Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ 0 . For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate ( ωH o ) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.

  20. Slew-rate dependence of tracer magnetization response in magnetic particle imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Saqlain A.; Krishnan, K. M., E-mail: kannanmk@uw.edu; Ferguson, R. M.

    2014-10-28

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ{sub 0} excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude (H{sub o}) and frequency (ω). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particlemore » Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ{sub 0}. For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate (ωH{sub o}) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.« less

  1. Prediction of iodine-131 biokinetics and radiation doses from therapy on the basis of tracer studies: an important question for therapy planning in nuclear medicine.

    PubMed

    Willegaignon, José; Pelissoni, Rogério A; Lima, Beatriz C G D; Sapienza, Marcelo T; Coura-Filho, George B; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from initial tracer to final therapy procedures to thus provide appropriate adjustments in therapeutic activities.

  2. Single-scan dual-tracer FLT+FDG PET tumor characterization.

    PubMed

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-02-07

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both (18)F-fluorodeoxyglucose (FDG) and (18)F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems--both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), K(net), and K(1) as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k(2), k(3)) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  3. Single-scan dual-tracer FLT+FDG PET tumor characterization

    NASA Astrophysics Data System (ADS)

    Kadrmas, Dan J.; Rust, Thomas C.; Hoffman, John M.

    2013-02-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10-60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging.

  4. Single-scan dual-tracer FLT+FDG PET tumor characterization

    PubMed Central

    Kadrmas, Dan J; Rust, Thomas C; Hoffman, John M

    2013-01-01

    Rapid multi-tracer PET aims to image two or more tracers in a single scan, simultaneously characterizing multiple aspects of physiology and function without the need for repeat imaging visits. Using dynamic imaging with staggered injections, constraints on the kinetic behavior of each tracer are applied to recover individual-tracer measures from the multi-tracer PET signal. The ability to rapidly and reliably image both 18F-fluorodeoxyglucose (FDG) and 18F-fluorothymidine (FLT) would provide complementary measures of tumor metabolism and proliferative activity, with important applications in guiding oncologic treatment decisions and assessing response. However, this tracer combination presents one of the most challenging dual-tracer signal-separation problems—both tracers have the same radioactive half-life, and the injection delay is short relative to the half-life and tracer kinetics. This work investigates techniques for single-scan dual-tracer FLT+FDG PET tumor imaging, characterizing the performance of recovering static and dynamic imaging measures for each tracer from dual-tracer datasets. Simulation studies were performed to characterize dual-tracer signal-separation performance for imaging protocols with both injection orders and injection delays of 10–60 min. Better performance was observed when FLT was administered first, and longer delays before administration of FDG provided more robust signal-separation and recovery of the single-tracer imaging measures. An injection delay of 30 min led to good recovery (R > 0.96) of static image values (e.g. SUV), Knet, and K1 as compared to values from separate, single-tracer time-activity curves. Recovery of higher order rate parameters (k2, k3) was less robust, indicating that information regarding these parameters was harder to recover in the presence of statistical noise and dual-tracer effects. Performance of the dual-tracer FLT(0 min)+FDG(32 min) technique was further evaluated using PET/CT imaging studies in five patients with primary brain tumors where the data from separate scans of each tracer were combined to synthesize dual-tracer scans with known single-tracer components; results demonstrated similar dual-tracer signal recovery performance. We conclude that rapid dual-tracer FLT+FDG tumor imaging is feasible and can provide quantitative tumor imaging measures comparable to those from conventional separate-scan imaging. PMID:23296314

  5. Using predictive uncertainty analysis to optimise tracer test design and data acquisition

    NASA Astrophysics Data System (ADS)

    Wallis, Ilka; Moore, Catherine; Post, Vincent; Wolf, Leif; Martens, Evelien; Prommer, Henning

    2014-07-01

    Tracer injection tests are regularly-used tools to identify and characterise flow and transport mechanisms in aquifers. Examples of practical applications are manifold and include, among others, managed aquifer recharge schemes, aquifer thermal energy storage systems and, increasingly important, the disposal of produced water from oil and shale gas wells. The hydrogeological and geochemical data collected during the injection tests are often employed to assess the potential impacts of injection on receptors such as drinking water wells and regularly serve as a basis for the development of conceptual and numerical models that underpin the prediction of potential impacts. As all field tracer injection tests impose substantial logistical and financial efforts, it is crucial to develop a solid a-priori understanding of the value of the various monitoring data to select monitoring strategies which provide the greatest return on investment. In this study, we demonstrate the ability of linear predictive uncertainty analysis (i.e. “data worth analysis”) to quantify the usefulness of different tracer types (bromide, temperature, methane and chloride as examples) and head measurements in the context of a field-scale aquifer injection trial of coal seam gas (CSG) co-produced water. Data worth was evaluated in terms of tracer type, in terms of tracer test design (e.g., injection rate, duration of test and the applied measurement frequency) and monitoring disposition to increase the reliability of injection impact assessments. This was followed by an uncertainty targeted Pareto analysis, which allowed the interdependencies of cost and predictive reliability for alternative monitoring campaigns to be compared directly. For the evaluated injection test, the data worth analysis assessed bromide as superior to head data and all other tracers during early sampling times. However, with time, chloride became a more suitable tracer to constrain simulations of physical transport processes, followed by methane. Temperature data was assessed as the least informative of the solute tracers. However, taking costs of data acquisition into account, it could be shown that temperature data when used in conjunction with other tracers was a valuable and cost-effective marker species due to temperatures low cost to worth ratio. In contrast, the high costs of acquisition of methane data compared to its muted worth, highlighted methanes unfavourable return on investment. Areas of optimal monitoring bore position as well as optimal numbers of bores for the investigated injection site were also established. The proposed tracer test optimisation is done through the application of common use groundwater flow and transport models in conjunction with publicly available tools for predictive uncertainty analysis to provide modelers and practitioners with a powerful yet efficient and cost effective tool which is generally applicable and easily transferrable from the present study to many applications beyond the case study of injection of treated CSG produced water.

  6. Application of fluorescently labeled tracer technique for detection of natural active macromolecules in Chinese medicine.

    PubMed

    Zeng, Qiao-Hui; Zhang, Xue-Wu; Xu, Kai-Peng; Jiang, Jian-Guo

    2014-02-01

    Active substances in traditional Chinese Medicine (TCM) contain not only a variety of small molecules, but also many other macromolecules (TCMMs), such as proteins, peptides and polysaccharides. Active TCMM can achieve good therapeutic effects by regulating the body's overall function with lower side effects. This review summarized the literatures published in recent years on the application of fluorescently labeled tracer technique for detection of natural active macromolecules in TCM. Classified by fluorescent markers, applications of fluorescein, rhodamine, and quantum dots (QDs) in TCMM active tracer are reviewed, and the methods and principles of TCMM fluorescent marker are illustrated. Studies on active TCMMs and their action mechanism are quite difficult due to a multitarget, multicomponent, and multipath system of TCM. However, the development of fluorescently labeled active tracer technique (FLATT) provides this research with new tools. Traditional fluorescent markers have many deficiencies, such as easily quenched, short luminous cycle, and intrinsic toxicity. Relatively, FLATT has many obvious advantages, and its application in TCMM is still at the early stage. In order to improve the overall level of fluorescence labeling in TCMM active tracer, the improvement on FLATT's detection sensitivity and biological affinity is urgent and critical to allow study of these interesting molecules.

  7. Characterization of Rhodamine-123 as a Tracer Dye for Use In In vitro Drug Transport Assays

    PubMed Central

    Forster, Samantha; Thumser, Alfred E.; Hood, Steve R.; Plant, Nick

    2012-01-01

    Fluorescent tracer dyes represent an important class of sub-cellular probes and allow the examination of cellular processes in real-time with minimal impact upon these processes. Such tracer dyes are becoming increasingly used for the examination of membrane transport processes, as they are easy-to-use, cost effective probe substrates for a number of membrane protein transporters. Rhodamine 123, a member of the rhodamine family of flurone dyes, has been used to examine membrane transport by the ABCB1 gene product, MDR1. MDR1 is viewed as the archetypal drug transport protein, and is able to efflux a large number of clinically relevant drugs. In addition, ectopic activity of MDR1 has been associated with the development of multiple drug resistance phenotype, which results in a poor patient response to therapeutic intervention. It is thus important to be able to examine the potential for novel compounds to be MDR1 substrates. Given the increasing use rhodamine 123 as a tracer dye for MDR1, a full characterisation of its spectral properties in a range of in vitro assay-relevant media is warranted. Herein, we determine λmax for excitation and emission or rhodamine 123 and its metabolite rhodamine 110 in commonly used solvents and extraction buffers, demonstrating that fluorescence is highly dependent on the chemical environment: Optimal parameters are 1% (v/v) methanol in HBSS, with λex = 505 nm, λem = 525 nm. We characterise the uptake of rhodamine 123 into cells, via both passive and active processes, and demonstrate that this occurs primarily through OATP1A2-mediated facilitated transport at concentrations below 2 µM, and via micelle-mediated passive diffusion above this. Finally, we quantify the intracellular sequestration and metabolism of rhodamine 123, demonstrating that these are both cell line-dependent factors that may influence the interpretation of transport assays. PMID:22470447

  8. Histological Methods for ex vivo Axon Tracing: A Systematic Review

    PubMed Central

    Heilingoetter, Cassandra L.; Jensen, Matthew B.

    2016-01-01

    Objectives Axon tracers provide crucial insight into the development, connectivity, and function of neural pathways. A tracer can be characterized as a substance that allows for the visualization of a neuronal pathway. Axon tracers have previously been used exclusively with in vivo studies; however, newer methods of axon tracing can be applied to ex vivo studies. Ex vivo studies involve the examination of cells or tissues retrieved from an organism. These post mortem methods of axon tracing offer several advantages, such as reaching inaccessible tissues and avoiding survival surgeries. Methods In order to evaluate the quality of the ex vivo tracing methods, we performed a systematic review of various experimental and comparison studies to discern the optimal method of axon tracing. Results The most prominent methods for ex vivo tracing involve enzymatic techniques or various dyes. It appears that there are a variety of techniques and conditions that tend to give better fluorescent character, clarity, and distance traveled in the neuronal pathway. We found direct comparison studies that looked at variables such as the type of tracer, time required, effect of temperature, and presence of calcium, however, there are other variables that have not been compared directly. Discussion We conclude there are a variety of promising tracing methods available depending on the experimental goals of the researcher, however, more direct comparison studies are needed to affirm the optimal method. PMID:27098542

  9. Histological methods for ex vivo axon tracing: A systematic review.

    PubMed

    Heilingoetter, Cassandra L; Jensen, Matthew B

    2016-07-01

    Axon tracers provide crucial insight into the development, connectivity, and function of neural pathways. A tracer can be characterized as a substance that allows for the visualization of a neuronal pathway. Axon tracers have previously been used exclusively with in vivo studies; however, newer methods of axon tracing can be applied to ex vivo studies. Ex vivo studies involve the examination of cells or tissues retrieved from an organism. These post mortem methods of axon tracing offer several advantages, such as reaching inaccessible tissues and avoiding survival surgeries. In order to evaluate the quality of the ex vivo tracing methods, we performed a systematic review of various experimental and comparison studies to discern the optimal method of axon tracing. The most prominent methods for ex vivo tracing involve enzymatic techniques or various dyes. It appears that there are a variety of techniques and conditions that tend to give better fluorescent character, clarity, and distance traveled in the neuronal pathway. We found direct comparison studies that looked at variables such as the type of tracer, time required, effect of temperature, and presence of calcium, however, there are other variables that have not been compared directly. We conclude there are a variety of promising tracing methods available depending on the experimental goals of the researcher, however, more direct comparison studies are needed to affirm the optimal method.

  10. Overview of SIMS-Based Experimental Studies of Tracer Diffusion in Solids and Application to Mg Self-Diffusion

    DOE PAGES

    Kulkarni, Nagraj S.; Bruce Warmack, Robert J.; Radhakrishnan, Bala; ...

    2014-09-23

    Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-highmore » vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).« less

  11. Determination of hyporheic travel time distributions and other parameters from concurrent conservative and reactive tracer tests by local-in-global optimization

    NASA Astrophysics Data System (ADS)

    Knapp, Julia L. A.; Cirpka, Olaf A.

    2017-06-01

    The complexity of hyporheic flow paths requires reach-scale models of solute transport in streams that are flexible in their representation of the hyporheic passage. We use a model that couples advective-dispersive in-stream transport to hyporheic exchange with a shape-free distribution of hyporheic travel times. The model also accounts for two-site sorption and transformation of reactive solutes. The coefficients of the model are determined by fitting concurrent stream-tracer tests of conservative (fluorescein) and reactive (resazurin/resorufin) compounds. The flexibility of the shape-free models give rise to multiple local minima of the objective function in parameter estimation, thus requiring global-search algorithms, which is hindered by the large number of parameter values to be estimated. We present a local-in-global optimization approach, in which we use a Markov-Chain Monte Carlo method as global-search method to estimate a set of in-stream and hyporheic parameters. Nested therein, we infer the shape-free distribution of hyporheic travel times by a local Gauss-Newton method. The overall approach is independent of the initial guess and provides the joint posterior distribution of all parameters. We apply the described local-in-global optimization method to recorded tracer breakthrough curves of three consecutive stream sections, and infer section-wise hydraulic parameter distributions to analyze how hyporheic exchange processes differ between the stream sections.

  12. Development of Standardized Mobile Tracer Correlation Approach for Large Area Emission Measurements (DRAFT UNDER EPA REVIEW)

    NASA Astrophysics Data System (ADS)

    Foster-wittig, T. A.; Thoma, E.; Green, R.; Hater, G.; Swan, N.; Chanton, J.

    2013-12-01

    Improved understanding of air emissions from large area sources such as landfills, waste water ponds, open-source processing, and agricultural operations is a topic of increasing environmental importance. In many cases, the size of the area source, coupled with spatial-heterogeneity, make direct (on-site) emission assessment difficult; methane emissions, from landfills for example, can be particularly complex [Thoma et al, 2009]. Recently, whole-facility (remote) measurement approaches based on tracer correlation have been utilized [Scheutz et al, 2011]. The approach uses a mobile platform to simultaneously measure a metered-release of a conservative gas (the tracer) along with the target compound (methane in the case of landfills). The known-rate tracer release provides a measure of atmospheric dispersion at the downwind observing location allowing the area source emission to be determined by a ratio calculation [Green et al, 2010]. Although powerful in concept, the approach has been somewhat limited to research applications due to the complexities and cost of the high-sensitivity measurement equipment required to quantify the part-per billion levels of tracer and target gas at kilometer-scale distances. The advent of compact, robust, and easy to use near-infrared optical measurement systems (such as cavity ring down spectroscopy) allow the tracer correlation approach to be investigated for wider use. Over the last several years, Waste Management Inc., the U.S. EPA, and collaborators have conducted method evaluation activities to determine the viability of a standardized approach through execution of a large number of field measurement trials at U.S. landfills. As opposed to previous studies [Scheutz et al, 2011] conducted at night (optimal plume transport conditions), the current work evaluated realistic use-scenarios; these scenarios include execution by non-scientist personnel, daylight operation, and full range of atmospheric condition (all plume transport conditions). The trials tested a novel tracer gas (acetylene), chosen for its performance and cost characteristics. This presentation will summarize method development activities for the field test trials (107 test days, with repeat measurements at 14 separate landfill sites). In addition to a brief description of the measurement technology, the method performance will be described, and primary data quality indicators and use conditions will be explored. Because measurements were taken under daylight and a variety of atmospheric conditions, the range of distance and wind conditions allows us to make conclusions about the strengths and limitations of the method. This enables us to show when and where it is possible to make a quality measurement using this technique and therefore develop a standardized method for large area emission measurements. Green, R. et al (2010). 'Methane Emission Measured at Two California Landfills by OTM-10 and an Acetylene Tracer Method.' Global Waste Management Symposium. San Antonio, Texas. Scheutz, C. et al. (2011). 'Quantification of multiple methane emission sources at landfills using a double tracer technique." Waste Management 31(5): 1009-1017. Thoma, E., et al (2009). 'Development of EPA OTM 10 for landfill applications." Journal of Environmental Engineering 136(8): 769-776.

  13. Gaining insights into reactive fluid-fractured rock systems using the temporal moments of a tracer breakthrough curve.

    PubMed

    Mukhopadhyay, Sumit; Liu, H-H; Spycher, N; Kennedy, B M

    2014-03-01

    In this paper, we show that the tracer breakthrough curves (BTCs), when the tracer chemically interacts with the solid matrix of a fractured rock, are considerably different than when it does not. Of particular interest, is the presence of a long pseudo steady state zone in the BTCs, where the tracer concentration is more or less constant over a long period of time. However, such a zone of constant concentration is not visible when either the tracer does not interact with the solid, or does so at an extremely fast rate. We show that these characteristics of the BTCs could be correlated to the parameters of the system. We develop expressions for the mean residence time and its variance for a chemically active and inactive tracer. We show that chemical interaction between the tracer and the solid increases the mean residence time and the increase depends on the distribution coefficient. We also show that the variance of residence time for a chemically active tracer is much larger than that for an inactive tracer, and it depends on both the distribution coefficient and the rate of chemical reaction. We verify these calculations against synthetic tracer BTCs, where the temporal moments are calculated by numerically integrating the tracer evolution curves. Even though we developed the mathematical expressions assuming an idealized fracture-matrix system, we believe that the mathematical expressions developed in this paper can be useful in gaining insights into reactive transport in a real fractured rock system. Published by Elsevier B.V.

  14. Coupling of active motion and advection shapes intracellular cargo transport.

    PubMed

    Khuc Trong, Philipp; Guck, Jochen; Goldstein, Raymond E

    2012-07-13

    Intracellular cargo transport can arise from passive diffusion, active motor-driven transport along cytoskeletal filament networks, and passive advection by fluid flows entrained by such cargo-motor motion. Active and advective transport are thus intrinsically coupled as related, yet different representations of the same underlying network structure. A reaction-advection-diffusion system is used here to show that this coupling affects the transport and localization of a passive tracer in a confined geometry. For sufficiently low diffusion, cargo localization to a target zone is optimized either by low reaction kinetics and decoupling of bound and unbound states, or by a mostly disordered cytoskeletal network with only weak directional bias. These generic results may help to rationalize subtle features of cytoskeletal networks, for example as observed for microtubules in fly oocytes.

  15. Development and characterization of food-grade tracers for the global grain tracing and recall system.

    PubMed

    Lee, Kyung-Min; Armstrong, Paul R; Thomasson, J Alex; Sui, Ruixiu; Casada, Mark; Herrman, Timothy J

    2010-10-27

    Tracing grain from the farm to its final processing destination as it moves through multiple grain-handling systems, storage bins, and bulk carriers presents numerous challenges to existing record-keeping systems. This study examines the suitability of coded caplets to trace grain, in particular, to evaluate methodology to test tracers' ability to withstand the rigors of a commercial grain handling and storage systems as defined by physical properties using measurement technology commonly applied to assess grain hardness and end-use properties. Three types of tracers to dispense into bulk grains for tracing the grain back to its field of origin were developed using three food-grade substances [processed sugar, pregelatinized starch, and silicified microcrystalline cellulose (SMCC)] as a major component in formulations. Due to a different functionality of formulations, the manufacturing process conditions varied for each tracer type, resulting in unique variations in surface roughness, weight, dimensions, and physical and spectroscopic properties before and after coating. The applied two types of coating [pregelatinized starch and hydroxypropylmethylcellulose (HPMC)] using an aqueous coating system containing appropriate plasticizers showed uniform coverage and clear coating. Coating appeared to act as a barrier against moisture penetration, to protect against mechanical damage of the surface of the tracers, and to improve the mechanical strength of tracers. The results of analysis of variance (ANOVA) tests showed the type of tracer, coating material, conditioning time, and a theoretical weight gain significantly influenced the morphological and physical properties of tracers. Optimization of these factors needs to be pursued to produce desirable tracers with consistent quality and performance when they flow with bulk grains throughout the grain marketing channels.

  16. Predictors of sentinel lymph node metastases in breast cancer-radioactivity and Ki-67.

    PubMed

    Thangarajah, Fabinshy; Malter, Wolfram; Hamacher, Stefanie; Schmidt, Matthias; Krämer, Stefan; Mallmann, Peter; Kirn, Verena

    2016-12-01

    Since the introduction of the sentinel node technique for breast cancer in the 1990s patient's morbidity was reduced. Tracer uptake is known to be dependent from lymph node integrity and activity of macrophages. The aim of this study was to assess whether radioactivity of the tracer can predict sentinel lymph node metastases. Furthermore, a potential association with Ki-67 index was examined. Non-invasive prediction of lymph node metastases could lead to a further decrease of morbidity. We retrospectively analyzed patients with primary breast cancer who underwent surgery at the Department of Obstetrics and Gynecology in the University Hospital of Cologne between 2012 and 2013. Injection of radioactive tracer was done a day before surgery in the department of Nuclear Medicine. Clinical data and radioactivity of the sentinel node measured the day before and intraoperatively were abstracted from patient's files. Of 246 patients, 64 patients had at least one, five patients had two and one patient had three positive sentinel lymph nodes. Occurrence of sentinel lymph node metastases was not associated with preoperative tracer activity (p = 0,319), intraoperative tracer activity of first sentinel node (p = 0,086) or with loss of tracer activity until operation (p = 0,909). There was no correlation between preoperative Ki-67 index and occurrence of lymph node metastases (p = 0,403). In our cohort, there was no correlation between radioactivity and sentinel node metastases. Tracer uptake might not only be influenced by lymph node metastases and does not predict metastatic lymph node involvement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stetzenbach, K.; Farnham, I.

    1996-06-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability ofmore » these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test.« less

  18. Potential microbial contamination during sampling of permafrost soil assessed by tracers

    NASA Astrophysics Data System (ADS)

    Bang-Andreasen, Toke; Schostag, Morten; Priemé, Anders; Elberling, Bo; Jacobsen, Carsten S.

    2017-02-01

    Drilling and handling of permanently frozen soil cores without microbial contamination is of concern because contamination e.g. from the active layer above may lead to incorrect interpretation of results in experiments investigating potential and actual microbial activity in these low microbial biomass environments. Here, we present an example of how microbial contamination from active layer soil affected analysis of the potentially active microbial community in permafrost soil. We also present the development and use of two tracers: (1) fluorescent plastic microspheres and (2) Pseudomonas putida genetically tagged with Green Fluorescent Protein production to mimic potential microbial contamination of two permafrost cores. A protocol with special emphasis on avoiding microbial contamination was developed and employed to examine how far microbial contamination can penetrate into permafrost cores. The quantity of tracer elements decreased with depth into the permafrost cores, but the tracers were detected as far as 17 mm from the surface of the cores. The results emphasize that caution should be taken to avoid microbial contamination of permafrost cores and that the application of tracers represents a useful tool to assess penetration of potential microbial contamination into permafrost cores.

  19. Potential microbial contamination during sampling of permafrost soil assessed by tracers.

    PubMed

    Bang-Andreasen, Toke; Schostag, Morten; Priemé, Anders; Elberling, Bo; Jacobsen, Carsten S

    2017-02-23

    Drilling and handling of permanently frozen soil cores without microbial contamination is of concern because contamination e.g. from the active layer above may lead to incorrect interpretation of results in experiments investigating potential and actual microbial activity in these low microbial biomass environments. Here, we present an example of how microbial contamination from active layer soil affected analysis of the potentially active microbial community in permafrost soil. We also present the development and use of two tracers: (1) fluorescent plastic microspheres and (2) Pseudomonas putida genetically tagged with Green Fluorescent Protein production to mimic potential microbial contamination of two permafrost cores. A protocol with special emphasis on avoiding microbial contamination was developed and employed to examine how far microbial contamination can penetrate into permafrost cores. The quantity of tracer elements decreased with depth into the permafrost cores, but the tracers were detected as far as 17 mm from the surface of the cores. The results emphasize that caution should be taken to avoid microbial contamination of permafrost cores and that the application of tracers represents a useful tool to assess penetration of potential microbial contamination into permafrost cores.

  20. Potential microbial contamination during sampling of permafrost soil assessed by tracers

    PubMed Central

    Bang-Andreasen, Toke; Schostag, Morten; Priemé, Anders; Elberling, Bo; Jacobsen, Carsten S.

    2017-01-01

    Drilling and handling of permanently frozen soil cores without microbial contamination is of concern because contamination e.g. from the active layer above may lead to incorrect interpretation of results in experiments investigating potential and actual microbial activity in these low microbial biomass environments. Here, we present an example of how microbial contamination from active layer soil affected analysis of the potentially active microbial community in permafrost soil. We also present the development and use of two tracers: (1) fluorescent plastic microspheres and (2) Pseudomonas putida genetically tagged with Green Fluorescent Protein production to mimic potential microbial contamination of two permafrost cores. A protocol with special emphasis on avoiding microbial contamination was developed and employed to examine how far microbial contamination can penetrate into permafrost cores. The quantity of tracer elements decreased with depth into the permafrost cores, but the tracers were detected as far as 17 mm from the surface of the cores. The results emphasize that caution should be taken to avoid microbial contamination of permafrost cores and that the application of tracers represents a useful tool to assess penetration of potential microbial contamination into permafrost cores. PMID:28230151

  1. Simultaneous 3D tracking of passive tracers and microtubule bundles in an active gel

    NASA Astrophysics Data System (ADS)

    Fan, Yi; Breuer, Kenneth S.; Fluids Team

    Kinesin-driven microtubule bundles generate a spontaneous flow in unconfined geometries. They exhibit properties of active matter, including the emergence of collective motion, reduction of apparent viscosity and consumption of local energy. Here we present results from 3D tracking of passive tracers (using Airy rings and 3D scanning) synchronized with 3D measurement of the microtubule bundles motion. This technique is applied to measure viscosity variation and collective flow in a confined geometry with particular attention paid to the self-pumping system recently reported by Wu et al. (2016). Results show that the viscosity in an equilibrium microtubule network is around half that of the isotropic unbundled microtubule solution. Cross-correlations of the active microtubule network and passive tracers define a neighborhood around microtubule bundles in which passive tracers are effectively transported. MRSEC NSF.

  2. Development and automation of a novel NET-PET tracer: [11C]Me@APPI.

    PubMed

    Mark, Christina; Bornatowicz, Birgit; Mitterhauser, Markus; Hendl, Matthias; Nics, Lukas; Haeusler, Daniela; Lanzenberger, Rupert; Berger, Michael L; Spreitzer, Helmut; Wadsak, Wolfgang

    2013-02-01

    The norepinephrine transporter (NET) is an important target for research in neurology and psychology and is involved in the pathophysiology of many neurodegenerative diseases such as Alzheimer's disease and attention deficient hyperactivity disorder. For visualization of NET abundance and deregulation, a novel PET tracer--[(11)C]Me@APPI--has been developed. For precursor synthesis, a 4-step synthesis starting from N-phenyl-o-phenylenediamine was set up. Radiosynthesis was established and optimized using standard methods and subsequently automated in a GE TRACERlabFx C Pro synthesizer. Preclinical testing was performed comprising affinity and selectivity testing on human membranes as well as stability and blood-brain-barrier-penetration using in-vitro models. Precursor molecule (APPI:0) and reference compound (Me@APPI) were synthesized with 26.5% and 21.4% overall yield, respectively. So far, 1.25±0.72 GBq [(11)C]Me@APPI with 54.35±7.80 GBq/μmol specific activity were produced (n=11). Affinity of reference compounds was determined as 8.08±1.75 nM for Me@APPI and 19.31±2.91 nM for APPI:0, respectively (n≥9). IAM-chromatography experiments (n=3) revealed a P(m) value of 1.51±0.34 for Me@APPI. Stability testing using human liver microsomes revealed that 99.5% of the tracer was found to be still intact after 60 minutes (n=4). Present data indicate that [(11)C]Me@APPI has promising properties to become a clinically useful NET-PET-tracer. Further in-vitro and in-vivo evaluations are currently under way. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. (18)F-alfatide II and (18)F-FDG dual-tracer dynamic PET for parametric, early prediction of tumor response to therapy.

    PubMed

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O; Xie, Qingguo; Li, Quanzheng; Eden, Henry S; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor's status under quasiconstant conditions. This study aimed to investigate the utility of dual-tracer dynamic PET imaging with (18)F-alfatide II ((18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and (18)F-FDG for parametric monitoring of tumor responses to therapy. We administered doxorubicin to one group of athymic nude mice with U87MG tumors and paclitaxel protein-bound particles to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting with injection via the tail vein catheters with (18)F-alfatide II, followed 40 min later by (18)F-FDG. To achieve signal separation of the 2 tracers, we fit a 3-compartment reversible model to the time-activity curve of (18)F-alfatide II for the 40 min before (18)F-FDG injection and then extrapolated to 90 min. The (18)F-FDG tumor time-activity curve was isolated from the 90-min dual-tracer tumor time-activity curve by subtracting the fitted (18)F-alfatide II tumor time-activity curve. With separated tumor time-activity curves, the (18)F-alfatide II binding potential (Bp = k3/k4) and volume of distribution (VD) and (18)F-FDG influx rate ((K1 × k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single-tracer imaging and to monitor therapeutic response. The transport and binding rate parameters K1-k3 of (18)F-alfatide II, calculated from the first 40 min of the dual-tracer dynamic scan, as well as Bp and VD correlated well with the parameters from the 60-min single-tracer scan (R(2) > 0.95). Compared with the results of single-tracer PET imaging, (18)F-FDG tumor uptake and influx were recovered well from dual-tracer imaging. On doxorubicin treatment, whereas no significant changes in static tracer uptake values of (18)F-alfatide II or (18)F-FDG were observed, both (18)F-alfatide II Bp and (18)F-FDG influx from kinetic analysis in tumors showed significant decreases. For therapy of MDA-MB-435 tumors with paclitaxel protein-bound particles, a significant decrease was observed only with (18)F-alfatide II Bp value from kinetic analysis but not (18)F-FDG influx. The parameters fitted with compartmental modeling from the dual-tracer dynamic imaging are consistent with those from single-tracer imaging, substantiating the feasibility of this methodology. Even though no significant differences in tumor size were found until 5 d after doxorubicin treatment started, at day 3 there were already substantial differences in (18)F-alfatide II Bp and (18)F-FDG influx rate. Dual-tracer imaging can measure (18)F-alfatide II Bp value and (18)F-FDG influx simultaneously to evaluate tumor angiogenesis and metabolism. Such changes are known to precede anatomic changes, and thus parametric imaging may offer the promise of early prediction of therapy response.

  4. Test-Retest Repeatability of Myocardial Blood Flow Measurements using Rubidium-82 Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Efseaff, Matthew

    Rubidium-82 positron emission tomography (PET) imaging has been proposed for routine myocardial blood flow (MBF) quantification. Few studies have investigated the test-retest repeatability of this method. Same-day repeatability of rest MBF imaging was optimized with a highly automated analysis program using image-derived input functions and a dual spillover correction (SOC). The effects of heterogeneous tracer infusion profiles and subject hemodynamics on test-retest repeatability were investigated at rest and during hyperemic stress. Factors affecting rest MBF repeatability included gender, suspected coronary artery disease, and dual SOC (p < 0.001). The best repeatability coefficient for same-day rest MBF was 0.20 mL/min/g using a six-minute scan-time, iterative reconstruction, dual SOC, resting rate-pressure-product (RPP) adjustment, and a left atrium image-derived input function. The serial study repeatabilities of the optimized protocol in subjects with homogeneous RPPs and tracer infusion profiles was 0.19 and 0.53 mL/min/g at rest and stress, and 0.95 for stress / rest myocardial flow reserve (MFR). Subjects with heterogeneous tracer infusion profiles and hemodynamic conditions had significantly less repeatable MBF measurements at rest, stress, and stress/rest flow reserve (p < 0.05).

  5. Development of Purine-Derived 18F-Labeled Pro-drug Tracers for Imaging of MRP1 Activity with PET

    PubMed Central

    2014-01-01

    Multidrug resistance-associated protein 1 (MRP1) is a drug efflux transporter that has been implicated in the pathology of several neurological diseases and is associated with development of multidrug resistance. To enable measurement of MRP1 function in the living brain, a series of 6-halopurines decorated with fluorinated side chains have been synthesized and evaluated as putative pro-drug tracers. The tracers were designed to undergo conjugation with glutathione within the brain and hence form the corresponding MRP1 substrate tracers in situ. 6-Bromo-7-(2-[18F]fluoroethyl)purine showed good brain uptake and rapid metabolic conversion. Dynamic PET imaging demonstrated a marked difference in brain clearance rates between wild-type and mrp1 knockout mice, suggesting that the tracer can allow noninvasive assessment of MRP1 activity in vivo. PMID:24456310

  6. Microfluidics: a groundbreaking technology for PET tracer production?

    PubMed

    Rensch, Christian; Jackson, Alexander; Lindner, Simon; Salvamoser, Ruben; Samper, Victor; Riese, Stefan; Bartenstein, Peter; Wängler, Carmen; Wängler, Björn

    2013-07-05

    Application of microfluidics to Positron Emission Tomography (PET) tracer synthesis has attracted increasing interest within the last decade. The technical advantages of microfluidics, in particular the high surface to volume ratio and resulting fast thermal heating and cooling rates of reagents can lead to reduced reaction times, increased synthesis yields and reduced by-products. In addition automated reaction optimization, reduced consumption of expensive reagents and a path towards a reduced system footprint have been successfully demonstrated. The processing of radioactivity levels required for routine production, use of microfluidic-produced PET tracer doses in preclinical and clinical imaging as well as feasibility studies on autoradiolytic decomposition have all given promising results. However, the number of microfluidic synthesizers utilized for commercial routine production of PET tracers is very limited. This study reviews the state of the art in microfluidic PET tracer synthesis, highlighting critical design aspects, strengths, weaknesses and presenting several characteristics of the diverse PET market space which are thought to have a significant impact on research, development and engineering of microfluidic devices in this field. Furthermore, the topics of batch- and single-dose production, cyclotron to quality control integration as well as centralized versus de-centralized market distribution models are addressed.

  7. Deproteinization assessment using isotopically enriched compounds to trace the coprecipitation of low-molecular-weight selenium species with proteins.

    PubMed

    Godin, Simon; Bouzas-Ramos, Diego; Fontagné-Dicharry, Stéphanie; Bouyssière, Brice; Bueno, Maïté

    2017-08-01

    Studies have shown that information related to the presence of low-molecular-weight metabolites is frequently lost after deproteinization of complex matrices, such as blood and plasma, during sample preparation. Therefore, the effect of several deproteinization reagents on low-molecular-weight selenium species has been compared by species-specific isotope labeling. Two isotopically enriched selenium tracers were used to mimic models of small inorganic anionic ( 77 Se-selenite) and organic zwitterionic ( 76 Se-selenomethionine) species. The results presented here show that the use of a methanol-acetonitrile-acetone (1:1:1 v/v/v) mixture provided approximately two times less tracer loss from plasma samples in comparison with the classic procedure using acetonitrile, which may not be optimal as it leads to important losses of low-molecular-weight selenium species. In addition, the possible interactions between selenium tracers and proteins were investigated, revealing that both coprecipitation phenomena and association with proteins were potentially responsible for selenite tracer losses during protein precipitation in blood samples. However, coprecipitation phenomena were found to be fully responsible for losses of both tracers observed in plasma samples and of the selenomethionine tracer in blood samples. This successfully applied strategy is anticipated to be useful for more extensive future studies in selenometabolomics. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Localization and diffusion of tracer particles in viscoelastic media with active force dipoles

    NASA Astrophysics Data System (ADS)

    Yasuda, Kento; Okamoto, Ryuichi; Komura, Shigeyuki; Mikhailov, Alexander S.

    2017-02-01

    Optical tracking in vivo experiments reveal that diffusion of particles in biological cells is strongly enhanced in the presence of ATP and the experimental data for animal cells could previously be reproduced within a phenomenological model of a gel with myosin motors acting within it (Fodor É. et al., EPL, 110 (2015) 48005). Here, the two-fluid model of a gel is considered where active macromolecules, described as force dipoles, cyclically operate both in the elastic and the fluid components. Through coarse-graining, effective equations of motions for idealized tracer particles displaying local deformations and local fluid flows are derived. The equation for deformation tracers coincides with the earlier phenomenological model and thus confirms it. For flow tracers, diffusion enhancement caused by active force dipoles in the fluid component, and thus due to metabolic activity, is found. The latter effect may explain why ATP-dependent diffusion enhancement could also be observed in bacteria that lack molecular motors in their skeleton or when the activity of myosin motors was chemically inhibited in eukaryotic cells.

  9. Preclinical validation of 111In-girentuximab-F(ab')2 as a tracer to image hypoxia related marker CAIX expression in head and neck cancer xenografts.

    PubMed

    Huizing, Fokko J; Hoeben, Bianca A W; Franssen, Gerben; Lok, Jasper; Heskamp, Sandra; Oosterwijk, Egbert; Boerman, Otto C; Bussink, Johan

    2017-09-01

    Hypoxia is a major cause of radio- and chemoresistance. Carbonic anhydrase IX (CAIX) is an endogenous hypoxia-related marker and an important prognostic marker. Assessment of CAIX expression may allow patient selection for hypoxia or CAIX-targeted treatment. The radioactive tracer 111 In-girentuximab-F(ab') 2 targets CAIX and can be used for SPECT imaging. Aim of this study was to validate and optimize 111 In-girentuximab-F(ab') 2 for imaging of CAIX expression in head and neck tumor xenografts. Affinity and internalization kinetics of 111 In-girentuximab-F(ab') 2 were determined in vitro using CAIX-expressing SK-RC-52 cells. Tumor targeting characteristics were determined in athymic mice with six different head and neck squamous cell carcinoma (SCCNij) xenografts. Tracer uptake was measured by ex vivo radioactivity counting. Intratumoral distribution of tracer uptake was measured using autoradiography and CAIX expression was determined immunohistochemically. 26% of the tracer was internalized into the SK-RC-52 cells within 24h. The half maximal inhibitory concentration (IC 50 ) was 0.69±0.08nM. In biodistribution studies SCCNij153 tumors showed the highest tracer uptake: 4.1±0.8ID/g at 24h p.i. Immunohistochemical and autoradiographic analyses of the xenografts showed a distinct spatial correlation between localization of the tracer and CAIX expression. 111 In-girentuximab-F(ab') 2 has a high affinity for CAIX. In vivo tumor uptake correlated strongly with CAIX expression in different head and neck xenografts. These results suggest that 111 In-girentuximab-F(ab') 2 is a promising tracer for imaging of hypoxia-related CAIX expression. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Sensitivity models and design protocol for partitioning tracer tests in alluvial aquifers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, M.; Butler, G.W.; Jackson, R.E.

    1997-11-01

    Zones of dense, nonaqueous phase liquids (DNAPLs) are difficult to characterize as to their volume, composition, and spatial distribution using conventional ground-water extraction and soil-sampling methods. Such incompletely characterized sites have negative consequences for those responsible for their remedial design, e.g., the uncertainties in the optimal placement of ground-water extraction wells and in the duration of remediation. However, the recent use of the partitioning interwell tracer test (PITT) to characterize DNAPL zones at sites in New Mexico [unsaturated alluvium] and in Ohio, Texas, and Utah [saturated alluvium] demonstrates that the volume and spatial distribution of residual DNAPL can be determinedmore » with accuracy. The PITT involves injection of a suite of tracers which reversibly partition to different degrees between the DNAPL and the ground water or soil air resulting in the chromatographic separation of the tracer signals observed at the extraction well(s). The design of a PITT requires careful consideration of the hydrostratigraphic, hydraulic, and certain geochemical properties of the alluvium being tested. A three-dimensional, numerical model of a heterogeneous alluvial aquifer containing DNAPL has been developed for use with the UTCHEM simulator to demonstrate partitioning tracer testing and to address questions that are frequently raised in its application. The simulations include (1) the estimation of DNAPL volume for the simple case where only residual DNAPL is present in heterogeneous alluvium, (2) sensitivity studies to demonstrate the effect of increasingly low residual DNAPL saturation on the tracer signal, and (3) the effect of free-phase DNAPL on the estimation of the volume of DNAPL present. Furthermore, the potential interference of sedimentary organic carbon as a DNAPL surrogate on the tracer signal is considered and shown to be readily resolved by the careful choice of tracers.« less

  11. TB tracer teams in South Africa: knowledge, practices and challenges of tracing TB patients to improve adherence.

    PubMed

    Bristow, Claire C; Podewils, Laura Jean; Bronner, Liza Ellen; Bantubani, Nonkqubela; Walt, Martie van der; Peters, Annatjie; Mametja, David

    2013-09-04

    In 2008-2009 the South African National Tuberculosis (TB) Program (NTP) implemented a national pilot project, the TB Tracer Project, aiming to decrease default rates and improve patient outcomes. The current study aimed to inform the NTP by describing the knowledge, attitudes, and practices of TB program personnel involved with tracing activities. A self-administered written questionnaire was sent to TB staff, managers and tracer team leaders to assess basic TB knowledge, attitudes and practices. Descriptive statistics were used to summarize results and the chi-squared statistic was used to compare responses of staff at facilities that participated in the TB Tracer Project (tracer) and those that followed standard NTP care (non-tracer). Of 560 total questionnaires distributed, 270 were completed and returned (response rate 48%). Total TB knowledge ranged from 70.8-86.3% correct across all response groups. However, just over half (range 50-59.3%) of each respondent group was able to correctly identify the four components of a DOT encounter. A patient no longer feeling sick was cited by 72.1% of respondents as the reason patients fail to adhere to treatment. Tracer teams were viewed as an effective means to get patients to return to treatment by 96.3% of health facility level respondents. Tracer team leaders reported concerns including lack of logistical support (41.7%), insufficient physical safety precautions (41.7%), and inadequate protection from contracting TB (39.1%). Upon patients returning to treatment at the clinic, facilities included in the TB Tracer Project were significantly more likely to discuss alternate DOTS arrangements than non-tracer facilities (79.2 vs. 66.4%, p = 0.03). This study identified key components of knowledge, attitudes, and practices regarding TB patient tracing activities in South Africa. Educating patients on the essential need to complete treatment irrespective of clinical symptoms may help improve treatment adherence. Future scale-up and integration of TB tracing activities as part of standard TB management should include provisions for standardized training of personnel on the critical elements of DOTS, and for ensuring appropriate supervision, logistical support, and physical safety and TB transmission protection of tracing teams.

  12. Measuring aerobic respiration in stream ecosystems using the resazurin-resorufin system

    Treesearch

    R. González-Pinzón; R. Haggerty; D.D. Myrold

    2012-01-01

    The use of smart tracers to study hydrologic systems is becoming more widespread. Smart tracers are compounds that irreversibly react in the presence of a process or condition under investigation. Resazurin (Raz) is a smart tracer that undergoes an irreversible reduction to resorufin (Rru) in the presence of cellular metabolic activity. We quantified the relationship...

  13. Dynamic dual-tracer PET reconstruction.

    PubMed

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  14. A comparative uptake study of multiplexed PET tracers in mice with turpentine-induced inflammation.

    PubMed

    Huang, Tingting; Wang, Hongliang; Tang, Ganghua; Liang, Xiang; Nie, Dahong; Yi, Chang; Wu, Kening

    2012-11-26

    The potential value of multiplexed positron emission tomography (PET) tracers in mice with turpentine-induced inflammation was evaluated and compared with 2-[¹⁸F]fluoro-2-deoxy-D-glucose ([¹⁸F]FDG) for glucose metabolism imaging. These PET tracers included [¹⁸F]fluoromethylcholine ([¹⁸F]FCH) for choline metabolism imaging, (S-[¹¹C]methyl)-D-cysteine ([¹¹C]DMCYS) for amino acid metabolism imaging, [¹¹C]bis(zinc(II)-dipicolylamine) ([¹¹C]DPA-Zn²⁺) for apoptosis imaging, 2-(4-N-[¹¹C]-methylaminophenyl)-6-hydroxybenzothiazole ([¹¹C]PIB) for β amyloid binding imaging, and [¹⁸F]fluoride (¹⁸F⁻) for bone metabolism imaging. In mice with turpentine-induced inflammation mice, the biodistribution of all the tracers mentioned above at 5, 15, 30, 45, and 60 min postinjection was determined. Also, the time-course curves of the tracer uptake ratios for inflammatory thigh muscle (IM) to normal uninflammatory thigh muscle (NM), IM to blood (BL), IM to brain (BR), and IM to liver (LI) were acquired, respectively. Moreover, PET imaging with the tracers within 60 min postinjection on a clinical PET/CT scanner was also conducted. [¹⁸F]FDG and ¹⁸F⁻ showed relatively higher uptake ratios for IM to NM, IM to BL, IM to BR, and IM to LI than [¹⁸F]FCH, [¹¹C]DPA-Zn²⁺, [¹¹C]DMCYS and [¹¹C]PIB, which were highly consistent with the results delineated in PET images. The results demonstrate that ¹⁸F⁻ seems to be a potential PET tracer for inflammation imaging. [¹⁸F]FCH and [¹¹C]DMCYS, with lower accumulation in inflammatory tissue than [¹⁸F]FDG, are not good PET tracers for inflammation imaging. As a promising inflammatory tracer, the chemical structure of [¹¹C]DPA-Zn²⁺ needs to be further optimized.

  15. Tracer tomography: design concepts and field experiments using heat as a tracer.

    PubMed

    Doro, Kennedy O; Cirpka, Olaf A; Leven, Carsten

    2015-04-01

    Numerical and laboratory studies have provided evidence that combining hydraulic tomography with tomographic tracer tests could improve the estimation of hydraulic conductivity compared with using hydraulic data alone. Field demonstrations, however, have been lacking so far, which we attribute to experimental difficulties. In this study, we present a conceptual design and experimental applications of tracer tomography at the field scale using heat as a tracer. In our experimental design, we improve active heat tracer testing by minimizing possible effects of heat losses, buoyancy, viscosity, and changing boundary conditions. We also utilize a cost-effective approach of measuring temperature changes in situ at high resolution. We apply the presented method to the 8 m thick heterogeneous, sandy gravel, alluvial aquifer at the Lauswiesen Hydrogeological Research Site in Tübingen, Germany. Results of our tomographic heat-tracer experiments are in line with earlier work on characterizing the aquifer at the test site. We demonstrate from the experimental perspective that tracer tomography is applicable and suitable at the field scale using heat as a tracer. The experimental results also demonstrate the potential of heat-tracer tomography as a cost-effective means for characterizing aquifer heterogeneity. © 2014, National Ground Water Association.

  16. Optimal weighting in fNL constraints from large scale structure in an idealised case

    NASA Astrophysics Data System (ADS)

    Slosar, Anže

    2009-03-01

    We consider the problem of optimal weighting of tracers of structure for the purpose of constraining the non-Gaussianity parameter fNL. We work within the Fisher matrix formalism expanded around fiducial model with fNL = 0 and make several simplifying assumptions. By slicing a general sample into infinitely many samples with different biases, we derive the analytic expression for the relevant Fisher matrix element. We next consider weighting schemes that construct two effective samples from a single sample of tracers with a continuously varying bias. We show that a particularly simple ansatz for weighting functions can recover all information about fNL in the initial sample that is recoverable using a given bias observable and that simple division into two equal samples is considerably suboptimal when sampling of modes is good, but only marginally suboptimal in the limit where Poisson errors dominate.

  17. Universal entrainment mechanism controls contact times with motile cells

    NASA Astrophysics Data System (ADS)

    Mathijssen, Arnold J. T. M.; Jeanneret, Raphaël; Polin, Marco

    2018-03-01

    Contact between particles and motile cells underpins a wide variety of biological processes, from nutrient capture and ligand binding to grazing, viral infection, and cell-cell communication. The window of opportunity for these interactions depends on the basic mechanism determining contact time, which is currently unknown. By combining experiments on three different species—Chlamydomonas reinhardtii, Tetraselmis subcordiforms, and Oxyrrhis marina—with simulations and analytical modeling, we show that the fundamental physical process regulating proximity to a swimming microorganism is hydrodynamic particle entrainment. The resulting distribution of contact times is derived within the framework of Taylor dispersion as a competition between advection by the cell surface and microparticle diffusion, and predicts the existence of an optimal tracer size that is also observed experimentally. Spatial organization of flagella, swimming speed, and swimmer and tracer size influence entrainment features and provide tradeoffs that may be tuned to optimize the estimated probabilities for microbial interactions like predation and infection.

  18. Prediction of Therapy Tumor-Absorbed Dose Estimates in I-131 Radioimmunotherapy Using Tracer Data Via a Mixed-Model Fit to Time Activity

    PubMed Central

    Koral, Kenneth F.; Avram, Anca M.; Kaminski, Mark S.; Dewaraja, Yuni K.

    2012-01-01

    Abstract Background For individualized treatment planning in radioimmunotherapy (RIT), correlations must be established between tracer-predicted and therapy-delivered absorbed doses. The focus of this work was to investigate this correlation for tumors. Methods The study analyzed 57 tumors in 19 follicular lymphoma patients treated with I-131 tositumomab and imaged with SPECT/CT multiple times after tracer and therapy administrations. Instead of the typical least-squares fit to a single tumor's measured time-activity data, estimation was accomplished via a biexponential mixed model in which the curves from multiple subjects were jointly estimated. The tumor-absorbed dose estimates were determined by patient-specific Monte Carlo calculation. Results The mixed model gave realistic tumor time-activity fits that showed the expected uptake and clearance phases even with noisy data or missing time points. Correlation between tracer and therapy tumor-residence times (r=0.98; p<0.0001) and correlation between tracer-predicted and therapy-delivered mean tumor-absorbed doses (r=0.86; p<0.0001) were very high. The predicted and delivered absorbed doses were within±25% (or within±75 cGy) for 80% of tumors. Conclusions The mixed-model approach is feasible for fitting tumor time-activity data in RIT treatment planning when individual least-squares fitting is not possible due to inadequate sampling points. The good correlation between predicted and delivered tumor doses demonstrates the potential of using a pretherapy tracer study for tumor dosimetry-based treatment planning in RIT. PMID:22947086

  19. Swim pressure on walls with curves and corners.

    PubMed

    Smallenburg, Frank; Löwen, Hartmut

    2015-09-01

    The concept of swim pressure quantifies the average force exerted by microswimmers on confining walls in nonequilibrium. Here we explore how the swim pressure depends on the wall curvature and on the presence of sharp corners in the wall. For active Brownian particles at high dilution, we present a coherent framework which describes the force and torque on passive particles of arbitrary shape, in the limit of large particles compared to the persistence length of the swimmer trajectories. The resulting forces can be used to derive, for example, the activity-induced depletion interaction between two disks, as well as to optimize the shape of a tracer particle for high swimming velocity. Our predictions are verifiable in experiments on passive obstacles exposed to a bath of bacteria or artificial microswimmers.

  20. Swim pressure on walls with curves and corners

    NASA Astrophysics Data System (ADS)

    Smallenburg, Frank; Löwen, Hartmut

    2015-09-01

    The concept of swim pressure quantifies the average force exerted by microswimmers on confining walls in nonequilibrium. Here we explore how the swim pressure depends on the wall curvature and on the presence of sharp corners in the wall. For active Brownian particles at high dilution, we present a coherent framework which describes the force and torque on passive particles of arbitrary shape, in the limit of large particles compared to the persistence length of the swimmer trajectories. The resulting forces can be used to derive, for example, the activity-induced depletion interaction between two disks, as well as to optimize the shape of a tracer particle for high swimming velocity. Our predictions are verifiable in experiments on passive obstacles exposed to a bath of bacteria or artificial microswimmers.

  1. A hybrid deconvolution approach for estimation of in vivo non-displaceable binding for brain PET targets without a reference region

    PubMed Central

    Mann, J. John; Ogden, R. Todd

    2017-01-01

    Background and aim Estimation of a PET tracer’s non-displaceable distribution volume (VND) is required for quantification of specific binding to its target of interest. VND is generally assumed to be comparable brain-wide and is determined either from a reference region devoid of the target, often not available for many tracers and targets, or by imaging each subject before and after blocking the target with another molecule that has high affinity for the target, which is cumbersome and involves additional radiation exposure. Here we propose, and validate for the tracers [11C]DASB and [11C]CUMI-101, a new data-driven hybrid deconvolution approach (HYDECA) that determines VND at the individual level without requiring either a reference region or a blocking study. Methods HYDECA requires the tracer metabolite-corrected concentration curve in blood plasma and uses a singular value decomposition to estimate the impulse response function across several brain regions from measured time activity curves. HYDECA decomposes each region’s impulse response function into the sum of a parametric non-displaceable component, which is a function of VND, assumed common across regions, and a nonparametric specific component. These two components differentially contribute to each impulse response function. Different regions show different contributions of the two components, and HYDECA examines data across regions to find a suitable common VND. HYDECA implementation requires determination of two tuning parameters, and we propose two strategies for objectively selecting these parameters for a given tracer: using data from blocking studies, and realistic simulations of the tracer. Using available test-retest data, we compare HYDECA estimates of VND and binding potentials to those obtained based on VND estimated using a purported reference region. Results For [11C]DASB and [11C]CUMI-101, we find that regardless of the strategy used to optimize the tuning parameters, HYDECA provides considerably less biased estimates of VND than those obtained, as is commonly done, using a non-ideal reference region. HYDECA test-retest reproducibility is comparable to that obtained using a VND determined from a non-ideal reference region, when considering the binding potentials BPP and BPND. Conclusions HYDECA can provide subject-specific estimates of VND without requiring a blocking study for tracers and targets for which a valid reference region does not exist. PMID:28459878

  2. Application of separable parameter space techniques to multi-tracer PET compartment modeling.

    PubMed

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-02-07

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  3. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    NASA Astrophysics Data System (ADS)

    Zhang, Jeff L.; Morey, A. Michael; Kadrmas, Dan J.

    2016-02-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg-Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models.

  4. Scientific Discovery through Advanced Computing (SciDAC-3) Partnership Project Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, Forest M.; Bochev, Pavel B.; Cameron-Smith, Philip J..

    The Applying Computationally Efficient Schemes for BioGeochemical Cycles ACES4BGC Project is advancing the predictive capabilities of Earth System Models (ESMs) by reducing two of the largest sources of uncertainty, aerosols and biospheric feedbacks, with a highly efficient computational approach. In particular, this project is implementing and optimizing new computationally efficient tracer advection algorithms for large numbers of tracer species; adding important biogeochemical interactions between the atmosphere, land, and ocean models; and applying uncertainty quanti cation (UQ) techniques to constrain process parameters and evaluate uncertainties in feedbacks between biogeochemical cycles and the climate system.

  5. Performance analysis of a new positron camera geometry for high speed, fine particle tracking

    NASA Astrophysics Data System (ADS)

    Sovechles, J. M.; Boucher, D.; Pax, R.; Leadbeater, T.; Sasmito, A. P.; Waters, K. E.

    2017-09-01

    A new positron camera arrangement was assembled using 16 ECAT951 modular detector blocks. A closely packed, cross pattern arrangement was selected to produce a highly sensitive cylindrical region for tracking particles with low activities and high speeds. To determine the capabilities of this system a comprehensive analysis of the tracking performance was conducted to determine the 3D location error and location frequency as a function of tracer activity and speed. The 3D error was found to range from 0.54 mm for a stationary particle, consistent for all tracer activities, up to 4.33 mm for a tracer with an activity of 3 MBq and a speed of 4 m · s-1. For lower activity tracers (<10-2 MBq), the error was more sensitive to increases in speed, increasing to 28 mm (at 4 m · s-1), indicating that at these conditions a reliable trajectory is not possible. These results expanded on, but correlated well with, previous literature that only contained location errors for tracer speeds up to 1.5 m · s-1. The camera was also used to track directly activated mineral particles inside a two-inch hydrocyclone and a 142 mm diameter flotation cell. A detailed trajectory, inside the hydrocyclone, of a  -212  +  106 µm (10-1 MBq) quartz particle displayed the expected spiralling motion towards the apex. This was the first time a mineral particle of this size had been successfully traced within a hydrocyclone, however more work is required to develop detailed velocity fields.

  6. Optimizing a 18F-NaF and 18F-FDG cocktail for PET assessment of metastatic castration-resistant prostate cancer

    PubMed Central

    Simoncic, Urban; Perlman, Scott; Liu, Glenn; Jeraj, Robert

    2015-01-01

    Background The 18F-NaF/18F-FDG cocktail PET/CT imaging has been proposed for patients with osseous metastases. This work aimed to optimize the cocktail composition for patients with metastatic castrate-resistant prostate cancer (mCRPC). Materials and methods Study was done on 6 patients with mCRPC that had analyzed a total of 26 lesions. Patients had 18F-NaF and 18F-FDG injections separated in time. Dynamic PET/CT imaging recorded uptake time course for both tracers into osseous metastases. 18F-NaF and 18F-FDG uptakes were decoupled by kinetic analysis, which enabled calculation of 18F-NaF and 18F-FDG Standardized Uptake Value (SUV) images. Peak, mean and total SUVs were evaluated for both tracers and all visible lesions. The 18F-NaF/18F-FDG cocktail was optimized under the assumption that contribution of both tracers to the image formation should be equal. SUV images for combined 18F-NaF/18F-FDG cocktail PET/CT imaging were generated for cocktail compositions with 18F-NaF:18F-FDG ratio varying from 1:8 to 1:2. Results The 18F-NaF peak and mean SUVs were on average 4-5 times higher than the 18F-FDG peak and mean SUVs, with inter-lesion coefficient-of-variations (COV) of 20%. 18F-NaF total SUV was on average 7 times higher than the 18F-FDG total SUV. When the 18F-NaF:18F-FDG ratio changed from 1:8 to 1:2, typical SUV on generated PET images increased by 50%, while change in uptake visual pattern was hardly noticeable. Conclusion The 18F-NaF/18F-FDG cocktail has equal contributions of both tracers to the image formation when the 18F-NaF:18F-FDG ratio is 1:5. Therefore we propose this ratio as the optimal cocktail composition for mCRPC patients. We also urge to strictly control the 18F-NaF/18F-FDG cocktail composition in any 18F-NaF/18F-FDG cocktail PET/CT exams. PMID:26378490

  7. Quantitation of lead-210 (210Pb) using lead-203 (203Pb) as a "Massless" yield tracer.

    PubMed

    May, D; Nelson, A N; Schultz, M K

    2017-05-01

    Determination of Pb-210 ( 210 Pb) in aqueous solution is a common radioanalytical challenge in environmental science. Widely used methods for undertaking these analyses (e.g., ASTM D7535) rely on the use of stable lead (Pb) as a yield tracer that takes into account losses of 210 Pb that inevitably occur during elemental/radiochemical separations of the procedures. Although effective, these methods introduce technical challenges that can be difficult to track and potentially introduce uncertainty that can be difficult to quantify. Examples of these challenges include interference from endogenous stable Pb in complex sample matrices; contamination of stable Pb carrier with 210 Pb; and high detection limits due to counting efficiency limitations. We hypothesized that many of these challenges could be avoided by the use of the electron-capture, gamma-emitting isotope, 203 Pb as a chemical yield tracer in the analysis of 210 Pb. A series of experiments were performed to evaluate the efficacy of 203 Pb as a tracer. Four different matrices were analyzed, including a complex matrix (hydraulic-fracturing produced fluids); and samples comprising less complicated matrices (i.e., river water, deionized water, and tap water). Separation techniques and counting methodologies were also compared and optimized. Due to a relatively short-half life (52 h), 203 Pb tracer is effectively massless for the purposes of chemical separations, allowing for reduced chromatography column resin bed volumes. Because 203 Pb is a gamma emitter (279 keV; 81% intensity), recovery can be determined non-destructively in a variety of matrices, including liquid scintillation cocktail. The use of liquid scintillation as a counting methodology allowed for determination of 210 Pb activities via 210 Pb or 210 Po; and recoveries of greater than 90% are routinely achievable using this approach. The improved method for the analysis of 210 Pb in aqueous matrices allows for the analysis of complex matrices, at reduced cost, while providing greater counting flexibility in achieving acceptable detections limits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Evaluation of single- and dual-porosity models for reproducing the release of external and internal tracers from heterogeneous waste-rock piles.

    PubMed

    Blackmore, S; Pedretti, D; Mayer, K U; Smith, L; Beckie, R D

    2018-05-30

    Accurate predictions of solute release from waste-rock piles (WRPs) are paramount for decision making in mining-related environmental processes. Tracers provide information that can be used to estimate effective transport parameters and understand mechanisms controlling the hydraulic and geochemical behavior of WRPs. It is shown that internal tracers (i.e. initially present) together with external (i.e. applied) tracers provide complementary and quantitative information to identify transport mechanisms. The analysis focuses on two experimental WRPs, Piles 4 and Pile 5 at the Antamina Mine site (Peru), where both an internal chloride tracer and externally applied bromide tracer were monitored in discharge over three years. The results suggest that external tracers provide insight into transport associated with relatively fast flow regions that are activated during higher-rate recharge events. In contrast, internal tracers provide insight into mechanisms controlling solutes release from lower-permeability zones within the piles. Rate-limited diffusive processes, which can be mimicked by nonlocal mass-transfer models, affect both internal and external tracers. The sensitivity of the mass-transfer parameters to heterogeneity is higher for external tracers than for internal tracers, as indicated by the different mean residence times characterizing the flow paths associated with each tracer. The joint use of internal and external tracers provides a more comprehensive understanding of the transport mechanisms in WRPs. In particular, the tracer tests support the notion that a multi-porosity conceptualization of WRPs is more adequate for capturing key mechanisms than a dual-porosity conceptualization. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. 10 CFR 39.39 - Records of material use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... used; (2) In the case of unsealed licensed material used for subsurface tracer studies, the radionuclide and quantity of activity used in a particular well and the disposition of any unused tracer...

  10. 10 CFR 39.39 - Records of material use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... used; (2) In the case of unsealed licensed material used for subsurface tracer studies, the radionuclide and quantity of activity used in a particular well and the disposition of any unused tracer...

  11. 10 CFR 39.39 - Records of material use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... used; (2) In the case of unsealed licensed material used for subsurface tracer studies, the radionuclide and quantity of activity used in a particular well and the disposition of any unused tracer...

  12. 10 CFR 39.39 - Records of material use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... used; (2) In the case of unsealed licensed material used for subsurface tracer studies, the radionuclide and quantity of activity used in a particular well and the disposition of any unused tracer...

  13. 10 CFR 39.39 - Records of material use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... used; (2) In the case of unsealed licensed material used for subsurface tracer studies, the radionuclide and quantity of activity used in a particular well and the disposition of any unused tracer...

  14. Radiation dosimetry of (68)Ga-PSMA-11 (HBED-CC) and preliminary evaluation of optimal imaging timing.

    PubMed

    Afshar-Oromieh, Ali; Hetzheim, Henrik; Kübler, Wolfgang; Kratochwil, Clemens; Giesel, Frederik L; Hope, Thomas A; Eder, Matthias; Eisenhut, Michael; Kopka, Klaus; Haberkorn, Uwe

    2016-08-01

    The clinical introduction of (68)Ga-PSMA-11 ("HBED-CC") ligand targeting the prostate-specific membrane antigen (PSMA) has been regarded as a significant step forward in the diagnosis of prostate cancer (PCa). In this study, we provide human dosimetry and data on optimal timing of PET imaging after injection. Four patients with recurrent PCa were referred for (68)Ga-PSMA-11 PET/CT. Whole-body PET/CTlow-dose scans were conducted at 5 min, and 1, 2, 3, 4 and 5 h after injection of 152-198 MBq (68)Ga-PSMA-11. Organs of moderate to high uptake were used as source organs; their total activity was determined at all measured time points. Time-activity curves were created for each source organ as well as for the remainder. The radiation exposure of a (68)Ga-PSMA-11 PET was identified using the OLINDA-EXM software. In addition, tracer uptake was measured in 16 sites of metastases. The highest tracer uptake was observed in the kidneys, liver, upper large intestine, and the urinary bladder. Mean organ doses were: kidneys 0.262 ± 0.098 mGy/MBq, liver 0.031 ± 0.004 mGy/MBq, upper large intestine 0.054 ± 0.041 mGy/MBq, urinary bladder 0.13 ± 0.059 mGy/MBq. The calculated mean effective dose was 0.023 ± 0.004 mSv/MBq (=0.085 ± 0.015 rem/mCi). Most tumor lesions (n = 16) were visible at 3 h p.i., while at all other time points many were not qualitatively present (10/16 visible at 1 h p.i.). The mean effective dose of a (68)Ga-PSMA-11 PET is 0.023 mSv/MBq. A 3-h delay after injection was optimal timing for (68)Ga-PSMA-11 PET/CT in this patient cohort.

  15. TB tracer teams in South Africa: knowledge, practices and challenges of tracing TB patients to improve adherence

    PubMed Central

    2013-01-01

    Background In 2008–2009 the South African National Tuberculosis (TB) Program (NTP) implemented a national pilot project, the TB Tracer Project, aiming to decrease default rates and improve patient outcomes. The current study aimed to inform the NTP by describing the knowledge, attitudes, and practices of TB program personnel involved with tracing activities. Methods A self-administered written questionnaire was sent to TB staff, managers and tracer team leaders to assess basic TB knowledge, attitudes and practices. Descriptive statistics were used to summarize results and the chi-squared statistic was used to compare responses of staff at facilities that participated in the TB Tracer Project (tracer) and those that followed standard NTP care (non-tracer). Results Of 560 total questionnaires distributed, 270 were completed and returned (response rate 48%). Total TB knowledge ranged from 70.8-86.3% correct across all response groups. However, just over half (range 50–59.3%) of each respondent group was able to correctly identify the four components of a DOT encounter. A patient no longer feeling sick was cited by 72.1% of respondents as the reason patients fail to adhere to treatment. Tracer teams were viewed as an effective means to get patients to return to treatment by 96.3% of health facility level respondents. Tracer team leaders reported concerns including lack of logistical support (41.7%), insufficient physical safety precautions (41.7%), and inadequate protection from contracting TB (39.1%). Upon patients returning to treatment at the clinic, facilities included in the TB Tracer Project were significantly more likely to discuss alternate DOTS arrangements than non-tracer facilities (79.2 vs. 66.4%, p = 0.03). Conclusions This study identified key components of knowledge, attitudes, and practices regarding TB patient tracing activities in South Africa. Educating patients on the essential need to complete treatment irrespective of clinical symptoms may help improve treatment adherence. Future scale-up and integration of TB tracing activities as part of standard TB management should include provisions for standardized training of personnel on the critical elements of DOTS, and for ensuring appropriate supervision, logistical support, and physical safety and TB transmission protection of tracing teams. PMID:24007294

  16. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    PubMed Central

    Zhang, Jeff L; Morey, A Michael; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. PMID:26788888

  17. Tracers for monitoring the activity of sodium/glucose cotransporters in health and disease

    DOEpatents

    Wright, Ernest M; Barrio, Jorge R; Hirayama, Bruce A; Kepe, Vladimir

    2014-09-30

    Radiolabeled tracers for sodium/glucose cotransporters (SGLTs), their synthesis, and their use are provided. The tracers are methyl or ethyl pyranosides having an equatorial hydroxyl group at carbon-2 and a C 1 preferred conformation, radiolabeled with .sup.18F, .sup.123I, or .sup.124I, or free hexoses radiolabeled with .sup.18F, .sup.123I, or .sup.124. Also provided are in vivo and in vitro techniques for using these and other tracers as analytical and diagnostic tools to study glucose transport, in health and disease, and to evaluate therapeutic interventions.

  18. The impacts of tracer selection and corrections for organic matter and particle size on the results of quantitative sediment fingerprinting. A case study from the Nene basin, UK.

    NASA Astrophysics Data System (ADS)

    Pulley, Simon; Ian, Foster; Paula, Antunes

    2014-05-01

    In recent years, sediment fingerprinting methodologies have gained widespread adoption when tracing sediment provenance in geomorphological research. A wide variety of tracers have been employed in the published literature, with corrections for particle size and organic matter applied when the researcher judged them necessary. This paper aims to explore the errors associated with tracer use by a comparison of fingerprinting results obtained using fallout and lithogenic radionuclides, geochemical, and mineral magnetic tracers in a range of environments located in the Nene basin, UK. Specifically, fingerprinting was undertaken on lake, reservoir and floodplain sediment cores, on actively transported suspended sediment and on overbank and channel bed sediment deposits. Tracer groups were investigated both alone and in combination to determine the differences between their sediment provenance predictions and potential causes of these differences. Additionally, simple organic and particle size corrections were applied to determine if they improve the agreement between the tracer group predictions. Key results showed that when fingerprinting contributions from channel banks to actively transported or recently deposited sediments the tracer group predictions varied by 24% on average. These differences could not be clearly attributed to changes in the sediment during erosion or transport. Instead, the most likely cause of differences was the pre-existing spatial variability in tracer concentrations within sediment sources, combined with highly localised erosion. This resulted in the collected sediment source samples not being representative of the actual sediment sources. Average differences in provenance predictions between the different tracer groups in lake, reservoir and floodplain sediment cores were lowest in the reservoir core at 19% and highest in some floodplain cores, with differences in predictions in excess of 50%. In these latter samples organic enrichment of the sediment, selective transport of fine particles and post-depositional chemical changes to the sediment were determined to be the likely cause of the differences. It was determined that organic and particle size corrections made the differences between tracer groups larger in most cases, although differences between tracer group predictions were reduced in two of the four floodplain cores.

  19. Relative distance between tracers as a measure of diffusivity within moving aggregates

    NASA Astrophysics Data System (ADS)

    Pönisch, Wolfram; Zaburdaev, Vasily

    2018-02-01

    Tracking of particles, be it a passive tracer or an actively moving bacterium in the growing bacterial colony, is a powerful technique to probe the physical properties of the environment of the particles. One of the most common measures of particle motion driven by fluctuations and random forces is its diffusivity, which is routinely obtained by measuring the mean squared displacement of the particles. However, often the tracer particles may be moving in a domain or an aggregate which itself experiences some regular or random motion and thus masks the diffusivity of tracers. Here we provide a method for assessing the diffusivity of tracer particles within mobile aggregates by measuring the so-called mean squared relative distance (MSRD) between two tracers. We provide analytical expressions for both the ensemble and time averaged MSRD allowing for direct identification of diffusivities from experimental data.

  20. Production of 68Ga-citrate Based on a SnO2 Generator for Short-Term Turpentine Oil-Induced Inflammation Imaging in Rats.

    PubMed

    Mirzaei, Alireza; Jalilian, Amir R; Akhlaghi, Mehdi; Beiki, Davood

    2016-01-01

    Gallium-68 citrate has been successfully applied in the PET imaging of infections and inflammation in some centers; however further evaluation of the tracer in inflammation models is of great importance. 68Ga-citrate prepared from [68Ga]GaCl3 (eluted form an SnO2 based 68Ge/68Ga generator) and sodium citrate at optimized conditions followed by quality control tests was injected to normal and turpentine-oil induced rats PET/CT imaging studies up to 290 min. 68Ga-citrate was prepared with acceptable radiochemical purity (>99 ITLC, >99% HPLC), specific activity (28-30 GBq/mM), chemical purity (Sn, Fe <0.3 ppm; Zn<0.2 ppm) in 15 min at 50°C. PET/CT imaging of the tracer demonstrated early detection of inflamed site in animal models in 60-80 min. This study demonstrated possible early detection of inflammation foci in vivo using 68Ga-citrate prepared using commercially available 68Ge/68Ga generators for PET imaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  1. Automatic and remote controlled ictal SPECT injection for seizure focus localization by use of a commercial contrast agent application pump.

    PubMed

    Feichtinger, Michael; Eder, Hans; Holl, Alexander; Körner, Eva; Zmugg, Gerda; Aigner, Reingard; Fazekas, Franz; Ott, Erwin

    2007-07-01

    In the presurgical evaluation of patients with partial epilepsy, the ictal single photon emission computed tomography (SPECT) is a useful noninvasive diagnostic tool for seizure focus localization. To achieve optimal SPECT scan quality, ictal tracer injection should be carried out as quickly as possible after the seizure onset and under highest safety conditions possible. Compared to the commonly used manual injection, an automatic administration of the radioactive tracer may provide higher quality standards for this procedure. In this study, therefore, we retrospectively analyzed efficiency and safety of an automatic injection system for ictal SPECT tracer application. Over a 31-month period, 26 patients underwent ictal SPECT by use of an automatic remote-controlled injection pump originally designed for CT-contrast agent application. Various factors were reviewed, including latency of ictal injection, radiation safety parameters, and ictal seizure onset localizing value. Times between seizure onset and tracer injection ranged between 3 and 48 s. In 21 of 26 patients ictal SPECT supported the localization of the epileptogenic focus in the course of the presurgical evaluation. In all cases ictal SPECT tracer injection was performed with a high degree of safety to patients and staff. Ictal SPECT by use of a remote-controlled CT-contrast agent injection system provides a high scan quality and is a safe and confirmatory presurgical evaluation technique in the epilepsy-monitoring unit.

  2. Optimal-mass-transfer-based estimation of glymphatic transport in living brain

    NASA Astrophysics Data System (ADS)

    Ratner, Vadim; Zhu, Liangjia; Kolesov, Ivan; Nedergaard, Maiken; Benveniste, Helene; Tannenbaum, Allen

    2015-03-01

    It was recently shown that the brain-wide cerebrospinal fluid (CSF) and interstitial fluid exchange system designated the `glymphatic pathway' plays a key role in removing waste products from the brain, similarly to the lymphatic system in other body organs . It is therefore important to study the flow patterns of glymphatic transport through the live brain in order to better understand its functionality in normal and pathological states. Unlike blood, the CSF does not flow rapidly through a network of dedicated vessels, but rather through para-vascular channels and brain parenchyma in a slower time-domain, and thus conventional fMRI or other blood-flow sensitive MRI sequences do not provide much useful information about the desired flow patterns. We have accordingly analyzed a series of MRI images, taken at different times, of the brain of a live rat, which was injected with a paramagnetic tracer into the CSF via the lumbar intrathecal space of the spine. Our goal is twofold: (a) find glymphatic (tracer) flow directions in the live rodent brain; and (b) provide a model of a (healthy) brain that will allow the prediction of tracer concentrations given initial conditions. We model the liquid flow through the brain by the diffusion equation. We then use the Optimal Mass Transfer (OMT) approach to derive the glymphatic flow vector field, and estimate the diffusion tensors by analyzing the (changes in the) flow. Simulations show that the resulting model successfully reproduces the dominant features of the experimental data. Keywords: inverse problem, optimal mass transport, diffusion equation, cerebrospinal fluid flow in brain, optical flow, liquid flow modeling, Monge Kantorovich problem, diffusion tensor estimation

  3. On the linearity of tracer bias around voids

    NASA Astrophysics Data System (ADS)

    Pollina, Giorgia; Hamaus, Nico; Dolag, Klaus; Weller, Jochen; Baldi, Marco; Moscardini, Lauro

    2017-07-01

    The large-scale structure of the Universe can be observed only via luminous tracers of the dark matter. However, the clustering statistics of tracers are biased and depend on various properties, such as their host-halo mass and assembly history. On very large scales, this tracer bias results in a constant offset in the clustering amplitude, known as linear bias. Towards smaller non-linear scales, this is no longer the case and tracer bias becomes a complicated function of scale and time. We focus on tracer bias centred on cosmic voids, I.e. depressions of the density field that spatially dominate the Universe. We consider three types of tracers: galaxies, galaxy clusters and active galactic nuclei, extracted from the hydrodynamical simulation Magneticum Pathfinder. In contrast to common clustering statistics that focus on auto-correlations of tracers, we find that void-tracer cross-correlations are successfully described by a linear bias relation. The tracer-density profile of voids can thus be related to their matter-density profile by a single number. We show that it coincides with the linear tracer bias extracted from the large-scale auto-correlation function and expectations from theory, if sufficiently large voids are considered. For smaller voids we observe a shift towards higher values. This has important consequences on cosmological parameter inference, as the problem of unknown tracer bias is alleviated up to a constant number. The smallest scales in existing data sets become accessible to simpler models, providing numerous modes of the density field that have been disregarded so far, but may help to further reduce statistical errors in constraining cosmology.

  4. Vertical Diffusivities of Active and Passive Tracers

    NASA Technical Reports Server (NTRS)

    Canuto, V. M.; Cheng, Y.; Howard, A. M.

    2010-01-01

    The climate models that include a carbon-cycle need the vertical diffusivity of a passive tracer. Since an expression for the latter is not available, it has been common practice to identify it with that of salt. The identification is questionable since T, S are active, not passive tracers. We present the first derivation of the diffusivity of a passive tracer in terms of Ri (Richardson number) and Rq (density ratio, ratio of salinity over temperature z-gradients). The following results have emerged: (a) The passive tracer diffusivity is an algebraic function of Ri, Rq. (b) In doubly stable regimes (DS, partial derivative of T with respect to z > 0, partial derivative of S with respect to z < 0), the passive scalar diffusivity is nearly the same as that of salt/heat for any values of Rq < 0 and Ri > 0. (c) In DC regimes (diffusive convection, partial derivative of T with respect to z < 0, partial derivative of S with respect to z < 0, Rq > 1), the passive scalar diffusivity is larger than that of salt. At Ri = O(1), it can be more than twice as large. (d) In SF regimes (salt fingers, partial derivative of T with respect to z > 0, partial derivative of S with respect to z > 0, Rq < 1), the passive scalar diffusivity is smaller than that of salt. At Ri = O(1), it can be less than half of it. (e) The passive tracer diffusivity predicted at the location of NATRE (North Atlantic Tracer Release Experiment) is discussed. (f) Perhaps the most relevant conclusion is that the common identification of the tracer diffusivity with that of salt is valid only in DS regimes. In the Southern Ocean, where there is the largest CO2 absorption, the dominant regime is diffusive convection discussed in (c) above.

  5. Development of [18F]afatinib as new TKI-PET tracer for EGFR positive tumors.

    PubMed

    Slobbe, Paul; Windhorst, Albert D; Stigter-van Walsum, Marijke; Schuit, Robert C; Smit, Egbert F; Niessen, Heiko G; Solca, Flavio; Stehle, Gerd; van Dongen, Guus A M S; Poot, Alex J

    2014-10-01

    Afatinib is an irreversible ErbB family blocker that was approved for the treatment of EGFR mutated non-small cell lung cancer in 2013. Positron emission tomography (PET) with fluorine-18 labeled afatinib provides a means to obtain improved understanding of afatinib tumor disposition in vivo. PET imaging with [(18)F]afatinib may also provide a method to select treatment responsive patients. The aim of this study was to label afatinib with fluorine-18 and evaluate its potential as TKI-PET tracer in tumor bearing mice. A radiochemically novel coupling, using peptide coupling reagent BOP, was explored and optimized to synthesize [(18)F]afatinib, followed by a metabolite analysis and biodistribution studies in two clinically relevant lung cancer cell lines, xenografted in nude mice. A reliable [(18)F]afatinib radiosynthesis was developed and the tracer could be produced in yields of 17.0 ± 2.5% calculated from [(18)F]F(-) and >98% purity. The identity of the product was confirmed by co-injection on HPLC with non-labeled afatinib. Metabolite analysis revealed a moderate rate of metabolism, with >80% intact tracer in plasma at 45 min p.i. Biodistribution studies revealed rapid tumor accumulation and good retention for a period of at least 2 hours, while background tissues showed rapid clearance of the tracer. We have developed a method to synthesize [(18)F]afatinib and related fluorine-18 labeled 4-anilinoquinazolines. [(18)F]Afatinib showed good stability in vivo, justifying further evaluation as a TKI-PET tracer. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Using diurnal temperature signals to infer vertical groundwater-surface water exchange

    USGS Publications Warehouse

    Irvine, Dylan J.; Briggs, Martin A.; Lautz, Laura K.; Gordon, Ryan P.; McKenzie, Jeffrey M.; Cartwright, Ian

    2017-01-01

    Heat is a powerful tracer to quantify fluid exchange between surface water and groundwater. Temperature time series can be used to estimate pore water fluid flux, and techniques can be employed to extend these estimates to produce detailed plan-view flux maps. Key advantages of heat tracing include cost-effective sensors and ease of data collection and interpretation, without the need for expensive and time-consuming laboratory analyses or induced tracers. While the collection of temperature data in saturated sediments is relatively straightforward, several factors influence the reliability of flux estimates that are based on time series analysis (diurnal signals) of recorded temperatures. Sensor resolution and deployment are particularly important in obtaining robust flux estimates in upwelling conditions. Also, processing temperature time series data involves a sequence of complex steps, including filtering temperature signals, selection of appropriate thermal parameters, and selection of the optimal analytical solution for modeling. This review provides a synthesis of heat tracing using diurnal temperature oscillations, including details on optimal sensor selection and deployment, data processing, model parameterization, and an overview of computing tools available. Recent advances in diurnal temperature methods also provide the opportunity to determine local saturated thermal diffusivity, which can improve the accuracy of fluid flux modeling and sensor spacing, which is related to streambed scour and deposition. These parameters can also be used to determine the reliability of flux estimates from the use of heat as a tracer.

  7. Fourier analysis of multitracer cosmological surveys

    NASA Astrophysics Data System (ADS)

    Abramo, L. Raul; Secco, Lucas F.; Loureiro, Arthur

    2016-02-01

    We present optimal quadratic estimators for the Fourier analysis of cosmological surveys that detect several different types of tracers of large-scale structure. Our estimators can be used to simultaneously fit the matter power spectrum and the biases of the tracers - as well as redshift-space distortions (RSDs), non-Gaussianities (NGs), or any other effects that are manifested through differences between the clusterings of distinct species of tracers. Our estimators reduce to the one by Feldman, Kaiser & Peacock (FKP) in the case of a survey consisting of a single species of tracer. We show that the multitracer estimators are unbiased, and that their covariance is given by the inverse of the multitracer Fisher matrix. When the biases, RSDs and NGs are fixed to their fiducial values, and one is only interested in measuring the underlying power spectrum, our estimators are projected into the estimator found by Percival, Verde & Peacock. We have tested our estimators on simple (lognormal) simulated galaxy maps, and we show that it performs as expected, being either equivalent or superior to the FKP method in all cases we analysed. Finally, we have shown how to extend the multitracer technique to include the one-halo term of the power spectrum.

  8. Solute transport and storage mechanisms in wetlands of the Everglades, south Florida

    USGS Publications Warehouse

    Harvey, Judson W.; Saiers, James E.; Newlin, Jessica T.

    2005-01-01

    Solute transport and storage processes in wetlands play an important role in biogeochemical cycling and in wetland water quality functions. In the wetlands of the Everglades, there are few data or guidelines to characterize transport through the heterogeneous flow environment. Our goal was to conduct a tracer study to help quantify solute exchange between the relatively fast flowing water in the open part of the water column and much more slowly moving water in thick floating vegetation and in the pore water of the underlying peat. We performed a tracer experiment that consisted of a constant‐rate injection of a sodium bromide (NaBr) solution for 22 hours into a 3 m wide, open‐ended flume channel in Everglades National Park. Arrival of the bromide tracer was monitored at an array of surface water and subsurface samplers for 48 hours at a distance of 6.8 m downstream of the injection. A one‐dimensional transport model was used in combination with an optimization code to identify the values of transport parameters that best explained the tracer observations. Parameters included dimensions and mass transfer coefficients describing exchange with both short (hours) and longer (tens of hours) storage zones as well as the average rates of advection and longitudinal dispersion in the open part of the water column (referred to as the “main flow zone”). Comparison with a more detailed set of tracer measurements tested how well the model's storage zones approximated the average characteristics of tracer movement into and out of the layer of thick floating vegetation and the pore water in the underlying peat. The rate at which the relatively fast moving water in the open water column was exchanged with slowly moving water in the layer of floating vegetation and in sediment pore water amounted to 50 and 3% h−1, respectively. Storage processes decreased the depth‐averaged velocity of surface water by 50% relative to the water velocity in the open part of the water column. As a result, flow measurements made with other methods that only work in the open part of the water column (e.g., acoustic Doppler) would have overestimated the true depth‐averaged velocity by a factor of 2. We hypothesize that solute exchange and storage in zones of floating vegetation and peat pore water increase contact time of solutes with biogeochemically active surfaces in this heterogeneous wetland environment.

  9. Atmospheric and soil-gas monitoring for surface leakage at the San Juan Basin CO{sub 2} pilot test site at Pump Canyon New Mexico, using perfluorocarbon tracers, CO{sub 2} soil-gas flux and soil-gas hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wells, Arthur W; Diehl, J Rodney; Strazisar, Brian R

    2012-05-01

    Near-surface monitoring and subsurface characterization activities were undertaken in collaboration with the Southwest Regional Carbon Sequestration Partnership on their San Juan Basin coal-bed methane pilot test site near Navajo City, New Mexico. Nearly 18,407 short tons (1.670 × 107 kg) of CO{sub 2} were injected into 3 seams of the Fruitland coal between July 2008 and April 2009. Between September 18 and October 30, 2008, two additions of approximately 20 L each of perfluorocarbon (PFC) tracers were mixed with the CO{sub 2} at the injection wellhead. PFC tracers in soil-gas and in the atmosphere were monitored over a period ofmore » 2 years using a rectangular array of permanent installations. Additional monitors were placed near existing well bores and at other locations of potential leakage identified during the pre-injection site survey. Monitoring was conducted using sorbent containing tubes to collect any released PFC tracer from soil-gas or the atmosphere. Near-surface monitoring activities also included CO{sub 2} surface flux and carbon isotopes, soil-gas hydrocarbon levels, and electrical conductivity in the soil. The value of the PFC tracers was demonstrated when a significant leakage event was detected near an offset production well. Subsurface characterization activities, including 3D seismic interpretation and attribute analysis, were conducted to evaluate reservoir integrity and the potential that leakage of injected CO{sub 2} might occur. Leakage from the injection reservoir was not detected. PFC tracers made breakthroughs at 2 of 3 offset wells which were not otherwise directly observable in produced gases containing 20–30% CO{sub 2}. These results have aided reservoir geophysical and simulation investigations to track the underground movement of CO{sub 2}. 3D seismic analysis provided a possible interpretation for the order of appearance of tracers at production wells.« less

  10. Active Lymphatic Drainage From the Eye Measured by Noninvasive Photoacoustic Imaging of Near-Infrared Nanoparticles.

    PubMed

    Yücel, Yeni H; Cardinell, Kirsten; Khattak, Shireen; Zhou, Xun; Lapinski, Michael; Cheng, Fang; Gupta, Neeru

    2018-06-01

    To visualize and quantify lymphatic drainage of aqueous humor from the eye to cervical lymph nodes in the dynamic state. A near-infrared tracer was injected into the right eye anterior chamber of 10 mice under general anesthesia. Mice were imaged with photoacoustic tomography before and 20 minutes, 2, 4, and 6 hours after injection. Tracer signal intensity was measured in both eyes and right and left neck lymph nodes at every time point and signal intensity slopes were calculated. Slope differences between right and left eyes and right and left nodes were compared using paired t-test. Neck nodes were examined with fluorescence optical imaging and histologically for the presence of tracer. Following right eye intracameral injection of tracer, an exponential decrease in tracer signal was observed from 20 minutes to 6 hours in all mice. Slope differences of the signal intensity between right and left eyes were significant (P < 0.001). Simultaneously, increasing tracer signal was observed in the right neck node from 20 minutes to 6 hours. Slope differences of the signal intensity between right and left neck nodes were significant (P = 0.0051). Ex vivo optical fluorescence imaging and histopathologic examination of neck nodes confirmed tracer presence within submandibular nodes. Active lymphatic drainage of aqueous from the eye to cervical lymph nodes was measured noninvasively by photoacoustic imaging of near-infrared nanoparticles. This unique in vivo assay may help to uncover novel drugs that target alternative outflow routes to lower IOP in glaucoma and may provide new insights into lymphatic drainage in eye health and disease.

  11. Extensive hydrothermal activity revealed by multi-tracer survey in the Wallis and Futuna region (SW Pacific)

    NASA Astrophysics Data System (ADS)

    Konn, C.; Fourré, E.; Jean-Baptiste, P.; Donval, J. P.; Guyader, V.; Birot, D.; Alix, A. S.; Gaillot, A.; Perez, F.; Dapoigny, A.; Pelleter, E.; Resing, J. A.; Charlou, J. L.; Fouquet, Y.

    2016-10-01

    The study area is close to the Wallis and Futuna Islands in the French EEZ. It exists on the western boundary of the fastest tectonic area in the world at the junction of the Lau and North-Fiji basins. At this place, the unstable back-arc accommodates the plate motion in three ways: (i) the north Fiji transform fault, (ii) numerous unstable spreading ridges, and (iii) large areas of recent volcanic activity. This instability creates bountiful opportunity for hydrothermal discharge to occur. Based on geochemical (CH4, TDM, 3He) and geophysical (nephelometry) tracer surveys: (1) no hydrothermal activity could be found on the Futuna Spreading Centre (FSC) which sets the western limit of hydrothermal activity; (2) four distinct hydrothermal active areas were identified: Kulo Lasi Caldera, Amanaki Volcano, Fatu Kapa and Tasi Tulo areas; (3) extensive and diverse hydrothermal manifestations were observed and especially a 2D distribution of the sources. At Kulo Lasi, our data and especially tracer ratios (CH4/3He 50×106 and CH4/TDM 4.5) reveal a transient CH4 input, with elevated levels of CH4 measured in 2010, that had vanished in 2011, most likely caused by an eruptive magmatic event. By contrast at Amanaki, vertical tracer profiles and tracer ratios point to typical seawater/basalt interactions. Fatu Kapa is characterised by a substantial spatial variability of the hydrothermal water column anomalies, most likely due to widespread focused and diffuse hydrothermal discharge in the area. In the Tasi Tulo zone, the hydrothermal signal is characterised by a total lack of turbidity, although other tracer anomalies are in the same range as in nearby Fatu Kapa. The background data set revealed the presence of a Mn and 3He chronic plume due to the extensive and cumulative venting over the entire area. To that respect, we believe that the joined domain composed of our active area and the nearby active area discovered in the East by Lupton et al. (2012) highly contribute to the extensive Tonga-Fiji plume and which thus may not originate from a sole source near the Samoa. Our results also emphasize and support the idea that back-arc hydrothermal systems have a significant input to the regional and global ocean and maybe more important than their MOR analogues.

  12. Radionuclide imaging of bone marrow disorders

    PubMed Central

    Agool, Ali; Glaudemans, Andor W. J. M.; Boersma, Hendrikus H.; Dierckx, Rudi A. J. O.; Vellenga, Edo

    2010-01-01

    Noninvasive imaging techniques have been used in the past for visualization the functional activity of the bone marrow compartment. Imaging with radiolabelled compounds may allow different bone marrow disorders to be distinguished. These imaging techniques, almost all of which use radionuclide-labelled tracers, such as 99mTc-nanocolloid, 99mTc-sulphur colloid, 111In-chloride, and radiolabelled white blood cells, have been used in nuclear medicine for several decades. With these techniques three separate compartments can be recognized including the reticuloendothelial system, the erythroid compartment and the myeloid compartment. Recent developments in research and the clinical use of PET tracers have made possible the analysis of additional properties such as cellular metabolism and proliferative activity, using 18F-FDG and 18F-FLT. These tracers may lead to better quantification and targeting of different cell systems in the bone marrow. In this review the imaging of different bone marrow targets with radionuclides including PET tracers in various bone marrow diseases are discussed. PMID:20625724

  13. A dual tracer ratio method for comparative emission measurements in an experimental dairy housing

    NASA Astrophysics Data System (ADS)

    Mohn, Joachim; Zeyer, Kerstin; Keck, Margret; Keller, Markus; Zähner, Michael; Poteko, Jernej; Emmenegger, Lukas; Schrade, Sabine

    2018-04-01

    Agriculture, and in particular dairy farming, is an important source of ammonia (NH3) and non-carbon dioxide greenhouse gas (GHG) emissions. This calls for the development and quantification of effective mitigation strategies. Our study presents the implementation of a dual tracer ratio method in a novel experimental dairy housing with two identical, but spatially separated housing areas. Modular design and flexible floor elements allow the assessment of structural, process engineering and organisational abatement measures at practical scale. Thereby, the emission reduction potential of specific abatement measures can be quantified in relation to a reference system. Emissions in the naturally ventilated housing are determined by continuous dosing of two artificial tracers (sulphur hexafluoride SF6, trifluoromethylsulphur pentafluoride SF5CF3) and their real-time detection in the ppt range with an optimized GC-ECD method. The two tracers are dosed into different experimental sections, which enables the independent assessment of both housing areas. Mass flow emissions of NH3 and GHGs are quantified by areal dosing of tracer gases and multipoint sampling as well as real-time analysis of both tracer and target gases. Validation experiments demonstrate that the technique is suitable for both areal and point emission sources and achieves an uncertainty of less than 10% for the mass emissions of NH3, methane (CH4) and carbon dioxide (CO2), which is superior to other currently available methods. Comparative emission measurements in this experimental dairy housing will provide reliable, currently unavailable information on emissions for Swiss dairy farming and demonstrate the reduction potential of mitigation measures for NH3, GHGs and potentially other pollutants.

  14. Rossby wave activity in a two-dimensional model - Closure for wave driving and meridional eddy diffusivity

    NASA Technical Reports Server (NTRS)

    Hitchman, Matthew H.; Brasseur, Guy

    1988-01-01

    A parameterization of the effects of Rossby waves in the middle atmosphere is proposed for use in two-dimensional models. By adding an equation for conservation of Rossby wave activity, closure is obtained for the meridional eddy fluxes and body force due to Rossby waves. Rossby wave activity is produced in a climatological fashion at the tropopause, is advected by a group velocity which is determined solely by model zonal winds, and is absorbed where it converges. Absorption of Rossby wave activity causes both an easterly torque and an irreversible mixing of potential vorticity, represented by the meridional eddy diffusivity, K(yy). The distribution of Rossby wave driving determines the distribution of K(yy), which is applied to all of the chemical constituents. This provides a self-consistent coupling of the wave activity with the winds, tracer distributions and the radiative field. Typical winter stratospheric values for K(yy) of 2 million sq m/sec are obtained. Poleward tracer advection is enhanced and meridional tracer gradients are reduced where Rossby wave activity is absorbed in the model.

  15. ⁸⁹Zr-Labeled Versus ¹²⁴I-Labeled αHER2 Fab with Optimized Plasma Half-Life for High-Contrast Tumor Imaging In Vivo.

    PubMed

    Mendler, Claudia T; Gehring, Torben; Wester, Hans-Jürgen; Schwaiger, Markus; Skerra, Arne

    2015-07-01

    Immuno-PET imaging of the tumor antigen HER2/neu allows for the noninvasive detection and monitoring of oncogene expression; such detection and monitoring are of prognostic value in patients with breast cancer. Compared with the full-size antibody trastuzumab, smaller protein tracers with more rapid blood clearance permit higher imaging contrast at earlier time points. Antigen-binding fragments (Fabs) of antibodies with moderately prolonged circulation achieved through the genetic fusion with a long, conformationally disordered chain of the natural amino acids Pro, Ala, and Ser (PASylation)-a biologic alternative to chemical conjugation with polyethylene glycol, PEG-offer a promising tracer format with improved pharmacokinetics for in vivo imaging. Recently, the transition metal radionuclide (89)Zr has attracted increasing interest for immuno-PET studies, complementing the conventional halogen radionuclide (124)I. To allow direct comparison of these 2 radioactive labels for the same protein tracer, the recombinant αHER2 Fab fused with 200 Pro, Ala, and Ser (PAS200) residues was either conjugated with (124)I via an iodination reagent or coupled with deferoxamine (Df) and complexed with (89)Zr. After confirmation of the stability of both radioconjugates and quality control in vitro, immuno-PET and biodistribution studies were performed with CD1-Foxn1(nu) mice bearing HER2-positive human tumor xenografts. (89)Zr⋅Df-Fab-PAS200 and (124)I-Fab-PAS200 showed specific tumor uptake of 11 and 2.3 percentage injected dose per gram 24 h after injection, respectively; both led to high tumor-to-blood (3.6 and 4.4, respectively) and tumor-to-muscle (20 and 43, respectively) ratios. With regard to off-target accumulation, overt (124)I activity was seen in the thyroid, as expected, whereas high kidney uptake was evident for (89)Zr; the latter was probably due to glomerular filtration and reabsorption of the protein tracer in proximal tubular cells. Both (89)Zr- and (124)I-labeled versions of αHER2 Fab-PAS200 allowed PET tumor imaging with high contrast. With its residualizing radiometal, the tracer (89)Zr⋅Df-Fab-PAS200 showed better in vivo stability and higher tumor uptake. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Parallel Optimization of an Earth System Model (100 Gigaflops and Beyond?)

    NASA Technical Reports Server (NTRS)

    Drummond, L. A.; Farrara, J. D.; Mechoso, C. R.; Spahr, J. A.; Chao, Y.; Katz, S.; Lou, J. Z.; Wang, P.

    1997-01-01

    We are developing an Earth System Model (ESM) to be used in research aimed to better understand the interactions between the components of the Earth System and to eventually predict their variations. Currently, our ESM includes models of the atmosphere, oceans and the important chemical tracers therein.

  17. Optimization of Antibody-Conjugated Magnetic Nanoparticles for Target Preconcentration and Immunoassays

    DTIC Science & Technology

    2010-01-01

    protein, AlexaFluor647– chicken IgG (Alexa647–chick IgG). Antibody-labeled MNPs (Alexa647– chick–MNPs) were used to preconcentrate the target via magnetic...separation and as the tracer to dem- onstrate binding to slides modified with anti- chicken IgG as a capture agent. A full optimization study of the...magnetically assisted transport evanescent field fluoroimmunoassay; Alexa647–chick–MNPs, MNPs functionalized with fluorescently labeled target chicken IgG

  18. EVALUATION OF LEAKAGE FROM FUME HOODS USING TRACER GAS, TRACER NANOPARTICLES AND NANOPOWDER HANDLING TEST METHODOLOGIES

    PubMed Central

    Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.

    2015-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285

  19. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    PubMed

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.

  20. A new compartmental method for the analysis of liver FDG kinetics in small animal models.

    PubMed

    Garbarino, Sara; Vivaldi, Valentina; Delbary, Fabrice; Caviglia, Giacomo; Piana, Michele; Marini, Cecilia; Capitanio, Selene; Calamia, Iolanda; Buschiazzo, Ambra; Sambuceti, Gianmario

    2015-12-01

    Compartmental analysis is a standard method to quantify metabolic processes using fluorodeoxyglucose-positron emission tomography (FDG-PET). For liver studies, this analysis is complex due to the hepatocyte capability to dephosphorylate and release glucose and FDG into the blood. Moreover, a tracer is supplied to the liver by both the hepatic artery and the portal vein, which is not visible in PET images. This study developed an innovative computational approach accounting for the reversible nature of FDG in the liver and directly computing the portal vein tracer concentration by means of gut radioactivity measurements. Twenty-one mice were subdivided into three groups: the control group 'CTR' (n = 7) received no treatment, the short-term starvation group 'STS' (n = 7) was submitted to food deprivation with free access to water within 48 h before imaging, and the metformin group 'MTF' (n = 7) was treated with metformin (750 mg/Kg per day) for 1 month. All mice underwent a dynamic micro-PET study for 50 min after an (18)F-FDG injection. The compartmental analysis considered two FDG pools (phosphorylated and free) in both the gut and liver. A tracer was carried into the liver by the hepatic artery and the portal vein, and tracer delivery from the gut was considered as the sole input for portal vein tracer concentration. Accordingly, both the liver and gut were characterized by two compartments and two exchange coefficients. Each one of the two two-compartment models was mathematically described by a system of differential equations, and data optimization was performed by applying a Newton algorithm to the inverse problems associated to these differential systems. All rate constants were stable in each group. The tracer coefficient from the free to the metabolized compartment in the liver was increased by STS, while it was unaltered by MTF. By contrast, the tracer coefficient from the metabolized to the free compartment was reduced by MTF and increased by STS. Data demonstrated that our method was able to analyze FDG kinetics under pharmacological or pathophysiological stimulation, quantifying the fraction of the tracer trapped in the liver or dephosphorylated and released into the bloodstream.

  1. Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

    DOE PAGES

    White, Mark D.; Esser, R. P.; McPherson, B. P.; ...

    2017-07-01

    The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, ismore » a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.« less

  2. Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Mark D.; Esser, R. P.; McPherson, B. P.

    The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, ismore » a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.« less

  3. Using Diurnal Temperature Signals to Infer Vertical Groundwater-Surface Water Exchange.

    PubMed

    Irvine, Dylan J; Briggs, Martin A; Lautz, Laura K; Gordon, Ryan P; McKenzie, Jeffrey M; Cartwright, Ian

    2017-01-01

    Heat is a powerful tracer to quantify fluid exchange between surface water and groundwater. Temperature time series can be used to estimate pore water fluid flux, and techniques can be employed to extend these estimates to produce detailed plan-view flux maps. Key advantages of heat tracing include cost-effective sensors and ease of data collection and interpretation, without the need for expensive and time-consuming laboratory analyses or induced tracers. While the collection of temperature data in saturated sediments is relatively straightforward, several factors influence the reliability of flux estimates that are based on time series analysis (diurnal signals) of recorded temperatures. Sensor resolution and deployment are particularly important in obtaining robust flux estimates in upwelling conditions. Also, processing temperature time series data involves a sequence of complex steps, including filtering temperature signals, selection of appropriate thermal parameters, and selection of the optimal analytical solution for modeling. This review provides a synthesis of heat tracing using diurnal temperature oscillations, including details on optimal sensor selection and deployment, data processing, model parameterization, and an overview of computing tools available. Recent advances in diurnal temperature methods also provide the opportunity to determine local saturated thermal diffusivity, which can improve the accuracy of fluid flux modeling and sensor spacing, which is related to streambed scour and deposition. These parameters can also be used to determine the reliability of flux estimates from the use of heat as a tracer. © 2016, National Ground Water Association.

  4. Optimal-mass-transfer-based estimation of glymphatic transport in living brain.

    PubMed

    Ratner, Vadim; Zhu, Liangjia; Kolesov, Ivan; Nedergaard, Maiken; Benveniste, Helene; Tannenbaum, Allen

    2015-02-21

    It was recently shown that the brain-wide cerebrospinal fluid (CSF) and interstitial fluid exchange system designated the 'glymphatic pathway' plays a key role in removing waste products from the brain, similarly to the lymphatic system in other body organs 1,2 . It is therefore important to study the flow patterns of glymphatic transport through the live brain in order to better understand its functionality in normal and pathological states. Unlike blood, the CSF does not flow rapidly through a network of dedicated vessels, but rather through para-vascular channels and brain parenchyma in a slower time-domain, and thus conventional fMRI or other blood-flow sensitive MRI sequences do not provide much useful information about the desired flow patterns. We have accordingly analyzed a series of MRI images, taken at different times, of the brain of a live rat, which was injected with a paramagnetic tracer into the CSF via the lumbar intrathecal space of the spine. Our goal is twofold: (a) find glymphatic (tracer) flow directions in the live rodent brain; and (b) provide a model of a (healthy) brain that will allow the prediction of tracer concentrations given initial conditions. We model the liquid flow through the brain by the diffusion equation. We then use the Optimal Mass Transfer (OMT) approach 3 to derive the glymphatic flow vector field, and estimate the diffusion tensors by analyzing the (changes in the) flow. Simulations show that the resulting model successfully reproduces the dominant features of the experimental data.

  5. Comparison of denitrification activity measurements in groundwater using cores and natural-gradient tracer tests

    USGS Publications Warehouse

    Smith, R.L.; Garabedian, S.P.; Brooks, M.H.

    1996-01-01

    The transport of many solutes in groundwater is dependent upon the relative rates of physical flow and microbial metabolism. Quantifying rates of microbial processes under subsurface conditions is difficult and is most commonly approximated using laboratory studies with aquifer materials. In this study, we measured in situ rates of denitrification in a nitrate- contaminated aquifer using small-scale, natural-gradient tracer tests and compared the results with rates obtained from laboratory incubations with aquifer core material. Activity was measured using the acetylene block technique. For the tracer tests, co-injection of acetylene and bromide into the aquifer produced a 30 ??M increase in nitrous oxide after 10 m of transport (23-30 days). An advection-dispersion transport model was modified to include an acetylene-dependent nitrous oxide production term and used to simulate the tracer breakthrough curves. The model required a 4-day lag period and a relatively low sensitivity to acetylene to match the narrow nitrous oxide breakthrough curves. Estimates of in situ denitrification rates were 0.60 and 1.51 nmol of N2O produced cm-3 aquifer day-1 for two successive tests. Aquifer core material collected from the tracer test site and incubated as mixed slurries in flasks and as intact cores yielded rates that were 1.2-26 times higher than the tracer test rate estimates. Results with the coring-dependent techniques were variable and subject to the small- scale heterogeneity within the aquifer, while the tracer tests integrated the heterogeneity along a flow path, giving a rate estimate that is more applicable to transport at the scale of the aquifer.

  6. Evaluating Contaminants of Emerging Concern as tracers of wastewater from septic systems.

    PubMed

    James, C Andrew; Miller-Schulze, Justin P; Ultican, Shawn; Gipe, Alex D; Baker, Joel E

    2016-09-15

    Bacterial and nutrient contamination from anthropogenic sources impacts fresh and marine waters, reducing water quality and restricting recreational and commercial activities. In many cases the source of this contamination is ambiguous, and a tracer or set of tracers linking contamination to source would be valuable. In this work, the effectiveness of utilizing a suite of Contaminants of Emerging Concern (CECs) as tracers of bacteria from human septic system effluent is investigated. Field sampling was performed at more than 20 locations over approximately 18 months and analyzed for a suite of CECs and fecal coliform bacteria. The sampling locations included seeps and small freshwater discharges to the shoreline. Sites were selected and grouped according to level of impact by septic systems as determined by previous field sampling programs. A subset of selected locations had been positively identified as being impacted by effluent from failing septic systems through dye testing. The CECs were selected based on their predominant use, their frequency of use, and putative fate and transport properties. In addition, two rounds of focused sampling were performed at selected sites to characterize short-term variations in CEC and fecal coliform concentrations, and to evaluate environmental persistence following source correction activities. The results indicate that a suite of common use compounds are suitable as generalized tracers of bacterial contamination from septic systems and that fate and transport properties are important in tracer selection. Highly recalcitrant or highly labile compounds likely follow different loss profiles in the subsurface compared to fecal bacteria and are not suitable tracers. The use of more than one tracer compound is recommended due to source variability of septic systems and to account for variations in the subsurface condition. In addition, concentrations of some CECs were measured in receiving waters at levels which suggested the potential for environmental harm, indicating that the possible risk presented from these sources warrants further investigation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Rapid solid-phase immunoassay for 6-keto prostaglandin F1 alpha on microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schramm, W.; Smith, R.H.; Jackson, T.M.

    1990-03-01

    We describe, for the measurement of 6-keto prostaglandin F1 alpha in biological media, a solid-phase immunoassay with immobilized antibodies that requires a total processing time of less than 2 h with hands-on time less than 30 min for 40 samples. The method combines the convenience of the microplate format with the sensitivity of radiolabeled prostaglandin derivatives as tracers in a competitive immunoassay. The intra- and interassay variations at 50% displacement of the radiolabeled prostaglandin derivative as tracer were 9.0% and 11.8%, respectively. At 50% displacement of the radiolabeled tracer, the sensitivity is about 20 pg per well. Optimal incubation timemore » is between 60 and 90 min. Nonspecific binding was less than 1% if about 8 pg of tracer (approximately 25,000 counts/min per well) was used. Inhibition curves of samples in different dilutions were parallel to standard curves. The variation of bound radiolabeled prostaglandin derivative within the wells of one microplate (n = 96) was less than 3%. Human plasma samples and medium from tissue culture assayed for 6-keto prostaglandin F1 alpha correlated well with results obtained with a solid-phase assay based on use of magnetic particles (r = 0.99, n = 24) for culture-medium samples; r = 0.99; n = 26 for plasma samples.« less

  8. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    NASA Astrophysics Data System (ADS)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  9. Control of motion stability of the line tracer robot using fuzzy logic and kalman filter

    NASA Astrophysics Data System (ADS)

    Novelan, M. S.; Tulus; Zamzami, E. M.

    2018-03-01

    Setting of motion and balance line tracer robot two wheels is actually a combination of a two-wheeled robot balance concept and the concept of line follower robot. The main objective of this research is to maintain the robot in an upright and can move to follow the line of the Wizard while maintaining balance. In this study the motion balance system on line tracer robot by considering the presence of a noise, so that it takes the estimator is used to mengestimasi the line tracer robot motion. The estimation is done by the method of Kalman Filter and the combination of Fuzzy logic-Fuzzy Kalman Filter called Kalman Filter, as well as optimal smooting. Based on the results of the study, the value of the output of the fuzzy results obtained from the sensor input value has been filtered before entering the calculation of the fuzzy. The results of the output of the fuzzy logic hasn’t been able to control dc motors are well balanced at the moment to be able to run. The results of the fuzzy logic by using membership function of triangular membership function or yet can control with good dc motor movement in order to be balanced

  10. Cerebrospinal and Interstitial Fluid Transport via the Glymphatic Pathway Modeled by Optimal Mass Transport

    PubMed Central

    Ratner, Vadim; Gao, Yi; Lee, Hedok; Elkin, Rena; Nedergaard, Maiken; Benveniste, Helene; Tannenbaum, Allen

    2017-01-01

    The glymphatic pathway is a system which facilitates continuous cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange and plays a key role in removing waste products from the rodent brain. Dysfunction of the glymphatic pathway may be implicated in the pathophysiology of Alzheimer's disease. Intriguingly, the glymphatic system is most active during deep wave sleep general anesthesia. By using paramagnetic tracers administered into CSF of rodents, we previously showed the utility of MRI in characterizing a macroscopic whole brain view of glymphatic transport but we have yet to define and visualize the specific flow patterns. Here we have applied an alternative mathematical analysis approach to a dynamic time series of MRI images acquired every 4 min over ∼3 hrs in anesthetized rats, following administration of a small molecular weight paramagnetic tracer into the CSF reservoir of the cisterna magna. We use Optimal Mass Transport (OMT) to model the glymphatic flow vector field, and then analyze the flow to find the network of CSF-ISF flow channels. We use 3D visualization computational tools to visualize the OMT defined network of CSF-ISF flow channels in relation to anatomical and vascular key landmarks from the live rodent brain. The resulting OMT model of the glymphatic transport network agrees largely with the current understanding of the glymphatic transport patterns defined by dynamic contrast-enhanced MRI revealing key CSF transport pathways along the ventral surface of the brain with a trajectory towards the pineal gland, cerebellum, hypothalamus and olfactory bulb. In addition, the OMT analysis also revealed some interesting previously unnoticed behaviors regarding CSF transport involving parenchymal streamlines moving from ventral reservoirs towards the surface of the brain, olfactory bulb and large central veins. PMID:28323163

  11. Cerebrospinal and interstitial fluid transport via the glymphatic pathway modeled by optimal mass transport.

    PubMed

    Ratner, Vadim; Gao, Yi; Lee, Hedok; Elkin, Rena; Nedergaard, Maiken; Benveniste, Helene; Tannenbaum, Allen

    2017-05-15

    The glymphatic pathway is a system which facilitates continuous cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange and plays a key role in removing waste products from the rodent brain. Dysfunction of the glymphatic pathway may be implicated in the pathophysiology of Alzheimer's disease. Intriguingly, the glymphatic system is most active during deep wave sleep general anesthesia. By using paramagnetic tracers administered into CSF of rodents, we previously showed the utility of MRI in characterizing a macroscopic whole brain view of glymphatic transport but we have yet to define and visualize the specific flow patterns. Here we have applied an alternative mathematical analysis approach to a dynamic time series of MRI images acquired every 4min over ∼3h in anesthetized rats, following administration of a small molecular weight paramagnetic tracer into the CSF reservoir of the cisterna magna. We use Optimal Mass Transport (OMT) to model the glymphatic flow vector field, and then analyze the flow to find the network of CSF-ISF flow channels. We use 3D visualization computational tools to visualize the OMT defined network of CSF-ISF flow channels in relation to anatomical and vascular key landmarks from the live rodent brain. The resulting OMT model of the glymphatic transport network agrees largely with the current understanding of the glymphatic transport patterns defined by dynamic contrast-enhanced MRI revealing key CSF transport pathways along the ventral surface of the brain with a trajectory towards the pineal gland, cerebellum, hypothalamus and olfactory bulb. In addition, the OMT analysis also revealed some interesting previously unnoticed behaviors regarding CSF transport involving parenchymal streamlines moving from ventral reservoirs towards the surface of the brain, olfactory bulb and large central veins. Copyright © 2017. Published by Elsevier Inc.

  12. Transport of a conservative and "smart" tracers' in a first-order creek: role of transient storage type

    USDA-ARS?s Scientific Manuscript database

    Quantification of microbial fate and transport in streams has become one of most important topics in studying biogeochemical properties and behavior of stream ecosystems. Using "smart" tracer such as resazurin (Raz) allows assessment of sediment-water interactions and associated biological activity ...

  13. Science Fair Projects. LC Science Tracer Bullet. TB 07-6

    ERIC Educational Resources Information Center

    Howland, Joyce, Comp.

    2007-01-01

    Selected sources in this bibliography provide guidance to students, parents, and teachers throughout the process of planning, developing, implementing and competing in science fair activities. Sources range in suitability from elementary to high school levels. This guide updates "Library of Congress Science Tracer Bullet" 01-4. More specialized…

  14. A NEW RAYTRACER FOR MODELING AU-SCALE IMAGING OF LINES FROM PROTOPLANETARY DISKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pontoppidan, Klaus M.; Meijerink, Rowin; Blake, Geoffrey A.

    The material that formed the present-day solar system originated in feeding zones in the inner solar nebula located at distances within approx20 AU from the Sun, known as the planet-forming zone. Meteoritic and cometary material contain abundant evidence for the presence of a rich and active chemistry in the planet-forming zone during the gas-rich phase of solar system formation. It is a natural conjecture that analogs can be found among the zoo of protoplanetary disks around nearby young stars. The study of the chemistry and dynamics of planet formation requires: (1) tracers of dense gas at 100-1000 K and (2)more » imaging capabilities of such tracers with 5-100 mas (0.5-20 AU) resolution, corresponding to the planet-forming zone at the distance of the closest star-forming regions. Recognizing that the rich infrared (2-200 mum) molecular spectrum recently discovered to be common in protoplanetary disks represents such a tracer, we present a new general ray-tracing code, RADLite, that is optimized for producing infrared line spectra and images from axisymmetric structures. RADLite can consistently deal with a wide range of velocity gradients, such as those typical for the inner regions of protoplanetary disks. The code is intended as a back-end for chemical and excitation codes, and can rapidly produce spectra of thousands of lines for grids of models for comparison with observations. Such radiative transfer tools will be crucial for constraining both the structure and chemistry of planet-forming regions, including data from current infrared imaging spectrometers and extending to the Atacama Large Millimeter Array and the next generation of Extremely Large Telescopes, the James Webb Space Telescope and beyond.« less

  15. Travel-time-based thermal tracer tomography

    NASA Astrophysics Data System (ADS)

    Somogyvári, Márk; Bayer, Peter; Brauchler, Ralf

    2016-05-01

    Active thermal tracer testing is a technique to get information about the flow and transport properties of an aquifer. In this paper we propose an innovative methodology using active thermal tracers in a tomographic setup to reconstruct cross-well hydraulic conductivity profiles. This is facilitated by assuming that the propagation of the injected thermal tracer is mainly controlled by advection. To reduce the effects of density and viscosity changes and thermal diffusion, early-time diagnostics are used and specific travel times of the tracer breakthrough curves are extracted. These travel times are inverted with an eikonal solver using the staggered grid method to reduce constraints from the pre-defined grid geometry and to improve the resolution. Finally, non-reliable pixels are removed from the derived hydraulic conductivity tomograms. The method is applied to successfully reconstruct cross-well profiles as well as a 3-D block of a high-resolution fluvio-aeolian aquifer analog data set. Sensitivity analysis reveals a negligible role of the injection temperature, but more attention has to be drawn to other technical parameters such as the injection rate. This is investigated in more detail through model-based testing using diverse hydraulic and thermal conditions in order to delineate the feasible range of applications for the new tomographic approach.

  16. MapMaker and PathTracer for tracking carbon in genome-scale metabolic models

    PubMed Central

    Tervo, Christopher J.; Reed, Jennifer L.

    2016-01-01

    Constraint-based reconstruction and analysis (COBRA) modeling results can be difficult to interpret given the large numbers of reactions in genome-scale models. While paths in metabolic networks can be found, existing methods are not easily combined with constraint-based approaches. To address this limitation, two tools (MapMaker and PathTracer) were developed to find paths (including cycles) between metabolites, where each step transfers carbon from reactant to product. MapMaker predicts carbon transfer maps (CTMs) between metabolites using only information on molecular formulae and reaction stoichiometry, effectively determining which reactants and products share carbon atoms. MapMaker correctly assigned CTMs for over 97% of the 2,251 reactions in an Escherichia coli metabolic model (iJO1366). Using CTMs as inputs, PathTracer finds paths between two metabolites. PathTracer was applied to iJO1366 to investigate the importance of using CTMs and COBRA constraints when enumerating paths, to find active and high flux paths in flux balance analysis (FBA) solutions, to identify paths for putrescine utilization, and to elucidate a potential CO2 fixation pathway in E. coli. These results illustrate how MapMaker and PathTracer can be used in combination with constraint-based models to identify feasible, active, and high flux paths between metabolites. PMID:26771089

  17. ¹³C Pathway Analysis for the Role of Formate in Electricity Generation by Shewanella Oneidensis MR-1 Using Lactate in Microbial Fuel Cells.

    PubMed

    Luo, Shuai; Guo, Weihua; Nealson, Kenneth H; Feng, Xueyang; He, Zhen

    2016-02-12

    Microbial fuel cell (MFC) is a promising technology for direct electricity generation from organics by microorganisms. The type of electron donors fed into MFCs affects the electrical performance, and mechanistic understanding of such effects is important to optimize the MFC performance. In this study, we used a model organism in MFCs, Shewanella oneidensis MR-1, and (13)C pathway analysis to investigate the role of formate in electricity generation and the related microbial metabolism. Our results indicated a synergistic effect of formate and lactate on electricity generation, and extra formate addition on the original lactate resulted in more electrical output than using formate or lactate as a sole electron donor. Based on the (13)C tracer analysis, we discovered decoupled cell growth and electricity generation in S. oneidensis MR-1 during co-utilization of lactate and formate (i.e., while the lactate was mainly metabolized to support the cell growth, the formate was oxidized to release electrons for higher electricity generation). To our best knowledge, this is the first time that (13)C tracer analysis was applied to study microbial metabolism in MFCs and it was demonstrated to be a valuable tool to understand the metabolic pathways affected by electron donors in the selected electrochemically-active microorganisms.

  18. Analytical method for measuring cosmogenic 35S in natural waters

    DOE PAGES

    Uriostegui, Stephanie H.; Bibby, Richard K.; Esser, Bradley K.; ...

    2015-05-18

    Here, cosmogenic sulfur-35 in water as dissolved sulfate ( 35SO 4) has successfully been used as an intrinsic hydrologic tracer in low-SO 4, high-elevation basins. Its application in environmental waters containing high SO 4 concentrations has been limited because only small amounts of SO 4 can be analyzed using current liquid scintillation counting (LSC) techniques. We present a new analytical method for analyzing large amounts of BaSO 4 for 35S. We quantify efficiency gains when suspending BaSO 4 precipitate in Inta-Gel Plus cocktail, purify BaSO 4 precipitate to remove dissolved organic matter, mitigate interference of radium-226 and its daughter productsmore » by selection of high purity barium chloride, and optimize LSC counting parameters for 35S determination in larger masses of BaSO 4. Using this improved procedure, we achieved counting efficiencies that are comparable to published LSC techniques despite a 10-fold increase in the SO 4 sample load. 35SO 4 was successfully measured in high SO 4 surface waters and groundwaters containing low ratios of 35S activity to SO 4 mass demonstrating that this new analytical method expands the analytical range of 35SO 4 and broadens the utility of 35SO 4 as an intrinsic tracer in hydrologic settings.« less

  19. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty--a combined analysis of tracer uptake distribution and component position.

    PubMed

    Suter, Basil; Testa, Enrique; Stämpfli, Patrick; Konala, Praveen; Rasch, Helmut; Friederich, Niklaus F; Hirschmann, Michael T

    2015-03-20

    The introduction of a standardized SPECT/CT algorithm including a localization scheme, which allows accurate identification of specific patterns and thresholds of SPECT/CT tracer uptake, could lead to a better understanding of the bone remodeling and specific failure modes of unicondylar knee arthroplasty (UKA). The purpose of the present study was to introduce a novel standardized SPECT/CT algorithm for patients after UKA and evaluate its clinical applicability, usefulness and inter- and intra-observer reliability. Tc-HDP-SPECT/CT images of consecutive patients (median age 65, range 48-84 years) with 21 knees after UKA were prospectively evaluated. The tracer activity on SPECT/CT was localized using a specific standardized UKA localization scheme. For tracer uptake analysis (intensity and anatomical distribution pattern) a 3D volumetric quantification method was used. The maximum intensity values were recorded for each anatomical area. In addition, ratios between the respective value in the measured area and the background tracer activity were calculated. The femoral and tibial component position (varus-valgus, flexion-extension, internal and external rotation) was determined in 3D-CT. The inter- and intraobserver reliability of the localization scheme, grading of the tracer activity and component measurements were determined by calculating the intraclass correlation coefficients (ICC). The localization scheme, grading of the tracer activity and component measurements showed high inter- and intra-observer reliabilities for all regions (tibia, femur and patella). For measurement of component position there was strong agreement between the readings of the two observers; the ICC for the orientation of the femoral component was 0.73-1.00 (intra-observer reliability) and 0.91-1.00 (inter-observer reliability). The ICC for the orientation of the tibial component was 0.75-1.00 (intra-observer reliability) and 0.77-1.00 (inter-observer reliability). The SPECT/CT algorithm presented combining the mechanical information on UKA component position, alignment and metabolic data is highly reliable and proved to be a valuable, consistent and useful tool for analysing postoperative knees after UKA. Using this standardized approach in clinical studies might be helpful in establishing the diagnosis in patients with pain after UKA.

  20. Early dynamic imaging in 68Ga- PSMA-11 PET/CT allows discrimination of urinary bladder activity and prostate cancer lesions.

    PubMed

    Uprimny, Christian; Kroiss, Alexander Stephan; Decristoforo, Clemens; Fritz, Josef; Warwitz, Boris; Scarpa, Lorenza; Roig, Llanos Geraldo; Kendler, Dorota; von Guggenberg, Elisabeth; Bektic, Jasmin; Horninger, Wolfgang; Virgolini, Irene Johanna

    2017-05-01

    PET/CT with 68 Ga-labelled prostate-specific membrane antigen (PSMA)-ligands has been proven to establish a promising imaging modality in the work-up of prostate cancer (PC) patients with biochemical relapse. Despite a high overall detection rate, the visualisation of local recurrence may be hampered by high physiologic tracer accumulation in the urinary bladder on whole body imaging, usually starting 60 min after injection. This study sought to verify whether early dynamic 68 Ga-PSMA-11 (HBED-CC)PET/CT can differentiate pathologic PC-related tracer uptake from physiologic tracer accumulation in the urinary bladder. Eighty consecutive PC patients referred to 68 Ga -PSMA-11 PET/CT were included in this retrospective analysis (biochemical relapse: n = 64; primary staging: n = 8; evaluation of therapy response/restaging: n = 8). In addition to whole-body PET/CT acquisition 60 min post injection early dynamic imaging of the pelvis in the first 8 min after tracer injection was performed. SUV max of pathologic lesions was calculated and time-activity curves were generated and compared to those of urinary bladder and areas of physiologic tracer uptake. A total of 55 lesions consistent with malignancy on 60 min whole body imaging exhibited also pathologic 68 Ga-PSMA-11 uptake during early dynamic imaging (prostatic bed/prostate gland: n = 27; lymph nodes: n = 12; bone: n = 16). All pathologic lesions showed tracer uptake within the first 3 min, whereas urinary bladder activity was absent within the first 3 min of dynamic imaging in all patients. Suv max was significantly higher in PC lesions in the first 6 min compared to urinary bladder accumulation (p < 0.001). In the subgroup of PC patients with biochemical relapse the detection rate of local recurrence could be increased from 20.3 to 29.7%. Early dynamic imaging in 68 Ga-PSMA-11 PET/CT reliably enables the differentiation of pathologic tracer uptake in PC lesions from physiologic bladder accumulation. Performance of early dynamic imaging in addition to whole body imaging 60 min after tracer injection might improve the detection rate of local recurrence in PC patients with biochemical relapse referred for 68 Ga-PSMA-11 PET/CT.

  1. Estimates of tracer-based piston-flow ages of groundwater from selected sites-National Water-Quality Assessment Program, 1992-2005

    USGS Publications Warehouse

    Hinkle, Stephen R.; Shapiro, Stephanie D.; Plummer, Niel; Busenberg, Eurybiades; Widman, Peggy K.; Casile, Gerolamo C.; Wayland, Julian E.

    2011-01-01

    This report documents selected age data interpreted from measured concentrations of environmental tracers in groundwater from 1,399 National Water-Quality Assessment (NAWQA) Program groundwater sites across the United States. The tracers of interest were chlorofluorocarbons (CFCs), sulfur hexafluoride (SF6), and tritium/helium-3 (3H/3He). Tracer data compiled for this analysis primarily were from wells representing two types of NAWQA groundwater studies - Land-Use Studies (shallow wells, usually monitoring wells, in recharge areas under dominant land-use settings) and Major-Aquifer Studies (wells, usually domestic supply wells, in principal aquifers and representing the shallow, used resource). Reference wells (wells representing groundwater minimally impacted by anthropogenic activities) associated with Land-Use Studies also were included. Tracer samples were collected between 1992 and 2005, although two networks sampled from 2006 to 2007 were included because of network-specific needs. Tracer data from other NAWQA Program components (Flow System Studies, which are assessments of processes and trends along groundwater flow paths, and various topical studies) were not compiled herein. Tracer data from NAWQA Land-Use Studies and Major-Aquifer Studies that previously had been interpreted and published are compiled herein (as piston-flow ages), but have not been reinterpreted. Tracer data that previously had not been interpreted and published are evaluated using documented methods and compiled with aqueous concentrations, equivalent atmospheric concentrations (for CFCs and SF6), estimates of tracer-based piston-flow ages, and selected ancillary data, such as redox indicators, well construction, and major dissolved gases (N2, O2, Ar, CH4, and CO2). Tracer-based piston-flow ages documented in this report are simplistic representations of the tracer data. Tracer-based piston-flow ages are a convenient means of conceptualizing groundwater age. However, the piston-flow model is based on the potentially limiting assumptions that tracer transport is advective and that no mixing occurs. Additional uncertainties can arise from tracer degradation, sorption, contamination, or fractionation; terrigenic (natural) sources of tracers; spatially variable atmospheric tracer concentrations; and incomplete understanding of mechanisms of recharge or of the conditions under which atmospheric tracers were partitioned to recharge. The effects of some of these uncertainties are considered herein. For example, degradation, contamination, or fractionation often can be identified or inferred. However, detailed analysis of the effects of such uncertainties on the tracer-based piston-flow ages is constrained by sparse data and an absence of complementary lines of evidence, such as detailed solute transport simulations. Thus, the tracer-based piston-flow ages compiled in this report represent only an initial interpretation of the tracer data.

  2. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    NASA Astrophysics Data System (ADS)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  3. A quantitative method for optimized placement of continuous air monitors.

    PubMed

    Whicker, Jeffrey J; Rodgers, John C; Moxley, John S

    2003-11-01

    Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

  4. Multi-Isotope Secondary Ion Mass Spectrometry Combining Heavy Water 2H with 15N Labeling As Complementary Tracers for Metabolic Heterogeneity at the Single-Cell Level

    NASA Astrophysics Data System (ADS)

    Kopf, S.; McGlynn, S.; Cowley, E.; Green, A.; Newman, D. K.; Orphan, V. J.

    2014-12-01

    Metabolic rates of microbial communities constitute a key physiological parameter for understanding the in situ growth constraints for life in any environment. Isotope labeling techniques provide a powerful approach for measuring such biological activity, due to the use of isotopically enriched substrate tracers whose incorporation into biological materials can be detected with high sensitivity by isotope-ratio mass spectrometry. Nano-meter scale secondary ion mass spectrometry (NanoSIMS) combined with stable isotope labeling provides a unique tool for studying the spatiometabolic activity of microbial populations at the single cell level in order to assess both community structure and population diversity. However, assessing the distribution and range of microbial activity in complex environmental systems with slow-growing organisms, diverse carbon and nitrogen sources, or heterotrophic subpopulations poses a tremendous technical challenge because the introduction of isotopically labeled substrates frequently changes the nutrient availability and can inflate or bias measures of activity. Here, we present the use of hydrogen isotope labeling with deuterated water as an important new addition to the isotopic toolkit and apply it for the determination of single cell microbial activities by NanoSIMS imaging. This tool provides a labeling technique that minimally alters any aquatic chemical environment, can be administered with strong labels even in minimal addition (natural background is very low), is an equally universal substrate for all forms of life even in complex, carbon and nitrogen saturated systems, and can be combined with other isotopic tracers. The combination of heavy water labeling with the most commonly used NanoSIMS tracer, 15N, is technically challenging but opens up a powerful new set of multi-tracer experiments for the study of microbial activity in complex communities. We present the first truly simultaneous single cell triple isotope system measurements of 2H/1H, 13C/12C and 15N/14N and apply it to study of microbial metabolic heterogeneity and nitrogen metabolism in a continuous culture case study. Our data provide insight into both the diversity of microbial activity rates, as well as patterns of ammonium utilization at the single cell level.

  5. Overview of positron emission tomography chemistry: clinical and technical considerations and combination with computed tomography.

    PubMed

    Koukourakis, G; Maravelis, G; Koukouraki, S; Padelakos, P; Kouloulias, V

    2009-01-01

    The concept of emission and transmission tomography was introduced by David Kuhl and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania. Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at the Washington University School of Medicine. Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a 3-dimensional image or map of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional space within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine. If the biologically active molecule chosen for PET is 18F-fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged give tissue metabolic activity in terms of regional glucose uptake. Although use of this tracer results in the most common type of PET scan, other tracer molecules are used in PET to image the tissue concentration of many other types of molecules of interest. The main role of this article was to analyse the available types of radiopharmaceuticals used in PET-CT along with the principles of its clinical and technical considerations.

  6. Novel ligands of Choline Acetyltransferase designed by in silico molecular docking, hologram QSAR and lead optimization

    NASA Astrophysics Data System (ADS)

    Kumar, Rajnish; Långström, Bengt; Darreh-Shori, Taher

    2016-08-01

    Recent reports have brought back the acetylcholine synthesizing enzyme, choline acetyltransferase in the mainstream research in dementia and the cholinergic anti-inflammatory pathway. Here we report, a specific strategy for the design of novel ChAT ligands based on molecular docking, Hologram Quantitative Structure Activity Relationship (HQSAR) and lead optimization. Molecular docking was performed on a series of ChAT inhibitors to decipher the molecular fingerprint of their interaction with the active site of ChAT. Then robust statistical fragment HQSAR models were developed. A library of novel ligands was generated based on the pharmacophoric and shape similarity scoring function, and evaluated in silico for their molecular interactions with ChAT. Ten of the top scoring invented compounds are reported here. We confirmed the activity of α-NETA, the only commercially available ChAT inhibitor, and one of the seed compounds in our model, using a new simple colorimetric ChAT assay (IC50 ~ 88 nM). In contrast, α-NETA exhibited an IC50 of ~30 μM for the ACh-degrading cholinesterases. In conclusion, the overall results may provide useful insight for discovering novel ChAT ligands and potential positron emission tomography tracers as in vivo functional biomarkers of the health of central cholinergic system in neurodegenerative disorders, such as Alzheimer’s disease.

  7. Modelling Water Uptake Provides a New Perspective on Grass and Tree Coexistence

    PubMed Central

    2015-01-01

    Root biomass distributions have long been used to infer patterns of resource uptake. These patterns are used to understand plant growth, plant coexistence and water budgets. Root biomass, however, may be a poor indicator of resource uptake because large roots typically do not absorb water, fine roots do not absorb water from dry soils and roots of different species can be difficult to differentiate. In a sub-tropical savanna, Kruger Park, South Africa, we used a hydrologic tracer experiment to describe the abundance of active grass and tree roots across the soil profile. We then used this tracer data to parameterize a water movement model (Hydrus 1D). The model accounted for water availability and estimated grass and tree water uptake by depth over a growing season. Most root biomass was found in shallow soils (0–20 cm) and tracer data revealed that, within these shallow depths, half of active grass roots were in the top 12 cm while half of active tree roots were in the top 21 cm. However, because shallow soils provided roots with less water than deep soils (20–90 cm), the water movement model indicated that grass and tree water uptake was twice as deep as would be predicted from root biomass or tracer data alone: half of grass and tree water uptake occurred in the top 23 and 43 cm, respectively. Niche partitioning was also greater when estimated from water uptake rather than tracer uptake. Contrary to long-standing assumptions, shallow grass root distributions absorbed 32% less water than slightly deeper tree root distributions when grasses and trees were assumed to have equal water demands. Quantifying water uptake revealed deeper soil water uptake, greater niche partitioning and greater benefits of deep roots than would be estimated from root biomass or tracer uptake data alone. PMID:26633177

  8. Particle Swarm Optimization for inverse modeling of solute transport in fractured gneiss aquifer

    NASA Astrophysics Data System (ADS)

    Abdelaziz, Ramadan; Zambrano-Bigiarini, Mauricio

    2014-08-01

    Particle Swarm Optimization (PSO) has received considerable attention as a global optimization technique from scientists of different disciplines around the world. In this article, we illustrate how to use PSO for inverse modeling of a coupled flow and transport groundwater model (MODFLOW2005-MT3DMS) in a fractured gneiss aquifer. In particular, the hydroPSO R package is used as optimization engine, because it has been specifically designed to calibrate environmental, hydrological and hydrogeological models. In addition, hydroPSO implements the latest Standard Particle Swarm Optimization algorithm (SPSO-2011), with an adaptive random topology and rotational invariance constituting the main advancements over previous PSO versions. A tracer test conducted in the experimental field at TU Bergakademie Freiberg (Germany) is used as case study. A double-porosity approach is used to simulate the solute transport in the fractured Gneiss aquifer. Tracer concentrations obtained with hydroPSO were in good agreement with its corresponding observations, as measured by a high value of the coefficient of determination and a low sum of squared residuals. Several graphical outputs automatically generated by hydroPSO provided useful insights to assess the quality of the calibration results. It was found that hydroPSO required a small number of model runs to reach the region of the global optimum, and it proved to be both an effective and efficient optimization technique to calibrate the movement of solute transport over time in a fractured aquifer. In addition, the parallel feature of hydroPSO allowed to reduce the total computation time used in the inverse modeling process up to an eighth of the total time required without using that feature. This work provides a first attempt to demonstrate the capability and versatility of hydroPSO to work as an optimizer of a coupled flow and transport model for contaminant migration.

  9. Dual-TRACER: High resolution fMRI with constrained evolution reconstruction.

    PubMed

    Li, Xuesong; Ma, Xiaodong; Li, Lyu; Zhang, Zhe; Zhang, Xue; Tong, Yan; Wang, Lihong; Sen Song; Guo, Hua

    2018-01-01

    fMRI with high spatial resolution is beneficial for studies in psychology and neuroscience, but is limited by various factors such as prolonged imaging time, low signal to noise ratio and scarcity of advanced facilities. Compressed Sensing (CS) based methods for accelerating fMRI data acquisition are promising. Other advanced algorithms like k-t FOCUSS or PICCS have been developed to improve performance. This study aims to investigate a new method, Dual-TRACER, based on Temporal Resolution Acceleration with Constrained Evolution Reconstruction (TRACER), for accelerating fMRI acquisitions using golden angle variable density spiral. Both numerical simulations and in vivo experiments at 3T were conducted to evaluate and characterize this method. Results show that Dual-TRACER can provide functional images with a high spatial resolution (1×1mm 2 ) under an acceleration factor of 20 while maintaining hemodynamic signals well. Compared with other investigated methods, dual-TRACER provides a better signal recovery, higher fMRI sensitivity and more reliable activation detection. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Water injection into vapor- and liquid-dominated reservoirs: Modeling of heat transfer and mass transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pruess, K.; Oldenburg, C.; Moridis, G.

    1997-12-31

    This paper summarizes recent advances in methods for simulating water and tracer injection, and presents illustrative applications to liquid- and vapor-dominated geothermal reservoirs. High-resolution simulations of water injection into heterogeneous, vertical fractures in superheated vapor zones were performed. Injected water was found to move in dendritic patterns, and to experience stronger lateral flow effects than predicted from homogeneous medium models. Higher-order differencing methods were applied to modeling water and tracer injection into liquid-dominated systems. Conventional upstream weighting techniques were shown to be adequate for predicting the migration of thermal fronts, while higher-order methods give far better accuracy for tracer transport.more » A new fluid property module for the TOUGH2 simulator is described which allows a more accurate description of geofluids, and includes mineral dissolution and precipitation effects with associated porosity and permeability change. Comparisons between numerical simulation predictions and data for laboratory and field injection experiments are summarized. Enhanced simulation capabilities include a new linear solver package for TOUGH2, and inverse modeling techniques for automatic history matching and optimization.« less

  11. When tractography meets tracer injections: a systematic study of trends and variation sources of diffusion-based connectivity.

    PubMed

    Aydogan, Dogu Baran; Jacobs, Russell; Dulawa, Stephanie; Thompson, Summer L; Francois, Maite Christi; Toga, Arthur W; Dong, Hongwei; Knowles, James A; Shi, Yonggang

    2018-04-16

    Tractography is a powerful technique capable of non-invasively reconstructing the structural connections in the brain using diffusion MRI images, but the validation of tractograms is challenging due to lack of ground truth. Owing to recent developments in mapping the mouse brain connectome, high-resolution tracer injection-based axonal projection maps have been created and quickly adopted for the validation of tractography. Previous studies using tracer injections mainly focused on investigating the match in projections and optimal tractography protocols. Being a complicated technique, however, tractography relies on multiple stages of operations and parameters. These factors introduce large variabilities in tractograms, hindering the optimization of protocols and making the interpretation of results difficult. Based on this observation, in contrast to previous studies, in this work we focused on quantifying and ranking the amount of performance variation introduced by these factors. For this purpose, we performed over a million tractography experiments and studied the variability across different subjects, injections, anatomical constraints and tractography parameters. By using N-way ANOVA analysis, we show that all tractography parameters are significant and importantly performance variations with respect to the differences in subjects are comparable to the variations due to tractography parameters, which strongly underlines the importance of fully documenting the tractography protocols in scientific experiments. We also quantitatively show that inclusion of anatomical constraints is the most significant factor for improving tractography performance. Although this critical factor helps reduce false positives, our analysis indicates that anatomy-informed tractography still fails to capture a large portion of axonal projections.

  12. Optimal-mass-transfer-based estimation of glymphatic transport in living brain

    PubMed Central

    Zhu, Liangjia; Kolesov, Ivan; Nedergaard, Maiken; Benveniste, Helene; Tannenbaum, Allen

    2016-01-01

    It was recently shown that the brain-wide cerebrospinal fluid (CSF) and interstitial fluid exchange system designated the ‘glymphatic pathway’ plays a key role in removing waste products from the brain, similarly to the lymphatic system in other body organs1,2. It is therefore important to study the flow patterns of glymphatic transport through the live brain in order to better understand its functionality in normal and pathological states. Unlike blood, the CSF does not flow rapidly through a network of dedicated vessels, but rather through para-vascular channels and brain parenchyma in a slower time-domain, and thus conventional fMRI or other blood-flow sensitive MRI sequences do not provide much useful information about the desired flow patterns. We have accordingly analyzed a series of MRI images, taken at different times, of the brain of a live rat, which was injected with a paramagnetic tracer into the CSF via the lumbar intrathecal space of the spine. Our goal is twofold: (a) find glymphatic (tracer) flow directions in the live rodent brain; and (b) provide a model of a (healthy) brain that will allow the prediction of tracer concentrations given initial conditions. We model the liquid flow through the brain by the diffusion equation. We then use the Optimal Mass Transfer (OMT) approach3 to derive the glymphatic flow vector field, and estimate the diffusion tensors by analyzing the (changes in the) flow. Simulations show that the resulting model successfully reproduces the dominant features of the experimental data. PMID:26877579

  13. Low energy cyclotron production of multivalent transition metals for PET imaging and therapy

    NASA Astrophysics Data System (ADS)

    Avila-Rodriguez, Miguel Angel

    Recent advances in high-resolution tomographs for small animals require the production of nonconventional long-lived positron emitters to label novel radiopharmaceuticals for PET-based molecular imaging. Radioisotopes with an appropriate half life to match the kinetics of slow biological processes will allow to researchers to study the phamacokinetics of PET ligands over several hours, or even days, on the same animal, with the injection of a single dose. In addition, radionuclides with a suitable half life can potentially be distributed from a central production site making them available in PET facilities that lack an in-house cyclotron. In the last few years there has been a growing interest in the use of PET ligands labeled with radiometals, particularly isotopes of copper, yttrium and zirconium. Future clinical applications of these tracers will require them to be produced reliably and efficiently. This thesis work deals with implementing and optimizing the production of the multivalent transition metals 61,64Cu, 86Y and 89Zr for molecular PET imaging and therapy. Our findings in the production of these radionuclides at high specific activity on an 11 MeV proton-only cyclotron are presented. Local applications of these tracers, including Cu-ATSM for in vivo quantification of hypoxia, synthesis of targeted radiopharmaceuticals using activated esters of DOTA, and a novel development of positron emitting resin microspheres, are also be discussed. As a result of this thesis work, metallic radionuclides are now efficiently produced on a weekly basis in sufficient quality and quantity for collaborating scientists at UW-Madison and external users in other Universities across the country.

  14. Performance evaluation of a novel high performance pinhole array detector module using NEMA NU-4 image quality phantom for four head SPECT Imaging

    NASA Astrophysics Data System (ADS)

    Rahman, Tasneem; Tahtali, Murat; Pickering, Mark R.

    2015-03-01

    Radiolabeled tracer distribution imaging of gamma rays using pinhole collimation is considered promising for small animal imaging. The recent availability of various radiolabeled tracers has enhanced the field of diagnostic study and is simultaneously creating demand for high resolution imaging devices. This paper presents analyses to represent the optimized parameters of a high performance pinhole array detector module using two different characteristics phantoms. Monte Carlo simulations using the Geant4 application for tomographic emission (GATE) were executed to assess the performance of a four head SPECT system incorporated with pinhole array collimators. The system is based on a pixelated array of NaI(Tl) crystals coupled to an array of position sensitive photomultiplier tubes (PSPMTs). The detector module was simulated to have 48 mm by 48 mm active area along with different pinhole apertures on a tungsten plate. The performance of this system has been evaluated using a uniform shape cylindrical water phantom along with NEMA NU-4 image quality (IQ) phantom filled with 99mTc labeled radiotracers. SPECT images were reconstructed where activity distribution is expected to be well visualized. This system offers the combination of an excellent intrinsic spatial resolution, good sensitivity and signal-to-noise ratio along with high detection efficiency over an energy range between 20-160 keV. Increasing number of heads in a stationary system configuration offers increased sensitivity at a spatial resolution similar to that obtained with the current SPECT system design with four heads.

  15. Automated cassette-based production of high specific activity [203/212Pb]peptide-based theranostic radiopharmaceuticals for image-guided radionuclide therapy for cancer.

    PubMed

    Li, Mengshi; Zhang, Xiuli; Quinn, Thomas P; Lee, Dongyoul; Liu, Dijie; Kunkel, Falk; Zimmerman, Brian E; McAlister, Daniel; Olewein, Keith; Menda, Yusuf; Mirzadeh, Saed; Copping, Roy; Johnson, Frances L; Schultz, Michael K

    2017-09-01

    A method for preparation of Pb-212 and Pb-203 labeled chelator-modified peptide-based radiopharmaceuticals for cancer imaging and radionuclide therapy has been developed and adapted for automated clinical production. Pre-concentration and isolation of radioactive Pb2+ from interfering metals in dilute hydrochloric acid was optimized using a commercially-available Pb-specific chromatography resin packed in disposable plastic columns. The pre-concentrated radioactive Pb2+ is eluted in NaOAc buffer directly to the reaction vessel containing chelator-modified peptides. Radiolabeling was found to proceed efficiently at 85°C (45min; pH 5.5). The specific activity of radiolabeled conjugates was optimized by separation of radiolabeled conjugates from unlabeled peptide via HPLC. Preservation of bioactivity was confirmed by in vivo biodistribution of Pb-203 and Pb-212 labeled peptides in melanoma-tumor-bearing mice. The approach has been found to be robustly adaptable to automation and a cassette-based fluid-handling system (Modular Lab Pharm Tracer) has been customized for clinical radiopharmaceutical production. Our findings demonstrate that the Pb-203/Pb-212 combination is a promising elementally-matched radionuclide pair for image-guided radionuclide therapy for melanoma, neuroendocrine tumors, and potentially other cancers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Modeling of CBM production, CO2 injection, and tracer movement at a field CO2 sequestration site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siriwardane, Hema J.; Bowes, Benjamin D.; Bromhal, Grant S.

    2012-07-01

    Sequestration of carbon dioxide in unmineable coal seams is a potential technology mainly because of the potential for simultaneous enhanced coalbed methane production (ECBM). Several pilot tests have been performed around the globe leading to mixed results. Numerous modeling efforts have been carried out successfully to model methane production and carbon dioxide (CO{sub 2}) injection. Sensitivity analyses and history matching along with several optimization tools were used to estimate reservoir properties and to investigate reservoir performance. Geological and geophysical techniques have also been used to characterize field sequestration sites and to inspect reservoir heterogeneity. The fate and movement of injectedmore » CO{sub 2} can be determined by using several monitoring techniques. Monitoring of perfluorocarbon (PFC) tracers is one of these monitoring technologies. As a part of this monitoring technique, a small fraction of a traceable fluid is added to the injection wellhead along with the CO{sub 2} stream at different times to monitor the timing and location of the breakthrough in nearby monitoring wells or offset production wells. A reservoir modeling study was performed to simulate a pilot sequestration site located in the San Juan coal basin of northern New Mexico. Several unknown reservoir properties at the field site were estimated by modeling the coal seam as a dual porosity formation and by history matching the methane production and CO{sub 2} injection. In addition to reservoir modeling of methane production and CO{sub 2} injection, tracer injection was modeled. Tracers serve as a surrogate for determining potential leakage of CO{sub 2}. The tracer was modeled as a non-reactive gas and was injected into the reservoir as a mixture along with CO{sub 2}. Geologic and geometric details of the field site, numerical modeling details of methane production, CO{sub 2} injection, and tracer injection are presented in this paper. Moreover, the numerical predictions of the tracer arrival times were compared with the measured field data. Results show that tracer modeling is useful in investigating movement of injected CO{sub 2} into the coal seam at the field site. Also, such new modeling techniques can be utilized to determine potential leakage pathways, and to investigate reservoir anisotropy and heterogeneity.« less

  17. A TRACER 3D Co-Culture tumour model for head and neck cancer.

    PubMed

    Young, Miki; Rodenhizer, Darren; Dean, Teresa; D'Arcangelo, Elisa; Xu, Bin; Ailles, Laurie; McGuigan, Alison P

    2018-05-01

    Cancer-associated fibroblasts (CAFs) are a key component of the tumour microenvironment and have been shown to play an important role in the progression of cancer. To probe these tumour-stroma interactions, we incorporated CAFs derived from head and neck cancer patients and squamous carcinoma cells of the hypopharynx (FaDu) into the Tissue Roll for the Analysis of Cellular Environment and Response (TRACER) platform to establish a co-culture platform that simulates the CAF-tumour microenvironmental interactions in head and neck tumours. TRACER culture involves infiltrating cells into a thin fibrous scaffold and then rolling the resulting biocomposite around a mandrel to generate a 3D and layered structure. Patterning the fibrous scaffold biocomposite during fabrication enables control over the specific location of different cell populations in the rolled configuration. Here, we optimized the seeding densities and configurations of the CAF and FaDu cell tissue sections to enable a robust 3D co-culture system under normoxic conditions. Co-culture of CAFs with FaDu cells produced negligible effects on radiation resistance, but did produce increases in proliferation rate and invasive cell migration at 24 and 48 h of culture. Our study provides the basis for use of our in vitro co-culture TRACER model to investigate the tumour-stroma interactions, and to bridge the translational gap between preclinical and clinical studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. FormTracer. A mathematica tracing package using FORM

    NASA Astrophysics Data System (ADS)

    Cyrol, Anton K.; Mitter, Mario; Strodthoff, Nils

    2017-10-01

    We present FormTracer, a high-performance, general purpose, easy-to-use Mathematica tracing package which uses FORM. It supports arbitrary space and spinor dimensions as well as an arbitrary number of simple compact Lie groups. While keeping the usability of the Mathematica interface, it relies on the efficiency of FORM. An additional performance gain is achieved by a decomposition algorithm that avoids redundant traces in the product tensors spaces. FormTracer supports a wide range of syntaxes which endows it with a high flexibility. Mathematica notebooks that automatically install the package and guide the user through performing standard traces in space-time, spinor and gauge-group spaces are provided. Program Files doi:http://dx.doi.org/10.17632/7rd29h4p3m.1 Licensing provisions: GPLv3 Programming language: Mathematica and FORM Nature of problem: Efficiently compute traces of large expressions Solution method: The expression to be traced is decomposed into its subspaces by a recursive Mathematica expansion algorithm. The result is subsequently translated to a FORM script that takes the traces. After FORM is executed, the final result is either imported into Mathematica or exported as optimized C/C++/Fortran code. Unusual features: The outstanding features of FormTracer are the simple interface, the capability to efficiently handle an arbitrary number of Lie groups in addition to Dirac and Lorentz tensors, and a customizable input-syntax.

  19. Fracture characterization in a deep geothermal reservoir

    NASA Astrophysics Data System (ADS)

    Rühaak, Wolfram; Hehn, Vera; Hassanzadegan, Alireza; Tischner, Torsten

    2017-04-01

    At the geothermal research drilling Horstberg in North West Germany studies for the characterization of a vertical fracture are performed. The fracture was created by a massive hydraulic stimulation in 2003 in approx. 3700 m depth within rocks of the middle Buntsandstein. The fracture surface is in the order of 100,000 m2, depending on the flow rate at which water is injected. Besides hydraulic characterization, multiple tracer tests are planned. At the depth of interest the reservoir temperature is around 150 °C, pressure is around 600 bar (60 MPa) and due to salinity the water density is around 1200 kg/m3. Knowledge of tracer stability and behavior at these reservoir conditions is limited. Additionally, the planned tracer tests will be performed within one single borehole. In a closed cycle water is injected into the inner pipe of the well (tubing), which is separated by a permanent packer from the outer pipe (annulus). The water is produced back from the annulus approximately 150 m above the injection point. Thus, the circulation of thermal water between two sandstone layers via an artificial fracture can be achieved. Tests will be carried out with different flow rates and accordingly with different pressures, resulting in different fracture areas. Due to this test setup tracer signals will be stacked and will remain for a longer time in the fracture - which is the reason why different tracers are required. For an optimal characterization both conservative and reactive tracers will be used and different injection methods (continuous, instantaneous and pulsed) will be applied. For a proper setup of the tracer test numerical modelling studies are performed in advance. The relevant thermal, hydraulic and chemical processes (mainly adsorption and degredation) are coupled, resulting in a THC model; additionally the dependence of fracture aperture and area on fluid pressure has to be considered. Instead of applying a mechanically coupled model (THMC) a simplified approach is applied which takes the pressure dependence of the fracture permeability into account by using constitutive relations. Results of this modeling study will be presented together with details of the planned field study.

  20. Positron emission tomography/computed tomography with 18F-fluorocholine improve tumor staging and treatment allocation in patients with hepatocellular carcinoma.

    PubMed

    Chalaye, Julia; Costentin, Charlotte E; Luciani, Alain; Amaddeo, Giuliana; Ganne-Carrié, Nathalie; Baranes, Laurence; Allaire, Manon; Calderaro, Julien; Azoulay, Daniel; Nahon, Pierre; Seror, Olivier; Mallat, Ariane; Soussan, Michael; Duvoux, Christophe; Itti, Emmanuel; Nault, Jean Charles

    2018-03-06

    Hepatocellular carcinoma (HCC) staging according to the Barcelona Clinical Liver Cancer (BCLC) classification is based on conventional imaging. The aim of our study was to assess the impact of dual-tracer 18F-fluorocholine and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) on tumor staging and treatment allocation. A total of 192 dual-tracer PET/CT scans (18F-fluorocholine and 18F-fluorodeoxyglucose PET/CT) were performed in 177 patients with HCC. BCLC staging and treatment proposal were retrospectively collected based on conventional imaging, along with any new lesions detected, and changes in BCLC classification or treatment allocation based on dual-tracer PET/CT. Patients were primarily men (87.5%) with cirrhosis (71%) due to alcohol ± non-alcoholic steatohepatitis (26%), viral infection (62%) or unknown causes (12%). Among 122 patients with PET/CT performed for staging, BCLC stage based on conventional imaging was 0/A in 61 patients (50%), B in 32 patients (26%) and C in 29 patients (24%). Dual-tracer PET/CT detected new lesions in 26 patients (21%), upgraded BCLC staging in 14 (11%) and modified treatment strategy in 17 (14%). In addition, dual-tracer PET/CT modified the final treatment in 4/9 (44%) patients with unexplained elevation of alpha-fetoprotein (AFP), 10/25 patients (40%) with doubtful lesions on conventional imaging and 3/36 patients (8%) waiting for liver transplantation without active HCC after tumor response following bridging therapy. When used for HCC staging, dual-tracer PET/CT enabled BCLC upgrading and treatment modification in 11% and 14% of patients, respectively. Dual-tracer PET/CT might also be useful in specific situations (an unexplained rise in AFP, doubtful lesions or pre-transplant evaluation of patients without active HCC). Using a combination of tracers 18F-fluorocholine and 18F-fluorodeoxyglucose when performing positron emission tomography/computed tomography (PET/CT), often called a PET scan, helps to identify new tumor lesions in patients with hepatocellular carcinoma. This technique enabled staging modification of patients' tumors and led to changes in treatment allocation in certain patients. Copyright © 2018. Published by Elsevier B.V.

  1. Evaluation of Parameter Uncertainty Reduction in Groundwater Flow Modeling Using Multiple Environmental Tracers

    NASA Astrophysics Data System (ADS)

    Arnold, B. W.; Gardner, P.

    2013-12-01

    Calibration of groundwater flow models for the purpose of evaluating flow and aquifer heterogeneity typically uses observations of hydraulic head in wells and appropriate boundary conditions. Environmental tracers have a wide variety of decay rates and input signals in recharge, resulting in a potentially broad source of additional information to constrain flow rates and heterogeneity. A numerical study was conducted to evaluate the reduction in uncertainty during model calibration using observations of various environmental tracers and combinations of tracers. A synthetic data set was constructed by simulating steady groundwater flow and transient tracer transport in a high-resolution, 2-D aquifer with heterogeneous permeability and porosity using the PFLOTRAN software code. Data on pressure and tracer concentration were extracted at well locations and then used as observations for automated calibration of a flow and transport model using the pilot point method and the PEST code. Optimization runs were performed to estimate parameter values of permeability at 30 pilot points in the model domain for cases using 42 observations of: 1) pressure, 2) pressure and CFC11 concentrations, 3) pressure and Ar-39 concentrations, and 4) pressure, CFC11, Ar-39, tritium, and He-3 concentrations. Results show significantly lower uncertainty, as indicated by the 95% linear confidence intervals, in permeability values at the pilot points for cases including observations of environmental tracer concentrations. The average linear uncertainty range for permeability at the pilot points using pressure observations alone is 4.6 orders of magnitude, using pressure and CFC11 concentrations is 1.6 orders of magnitude, using pressure and Ar-39 concentrations is 0.9 order of magnitude, and using pressure, CFC11, Ar-39, tritium, and He-3 concentrations is 1.0 order of magnitude. Data on Ar-39 concentrations result in the greatest parameter uncertainty reduction because its half-life of 269 years is similar to the range of transport times (hundreds to thousands of years) in the heterogeneous synthetic aquifer domain. The slightly higher uncertainty range for the case using all of the environmental tracers simultaneously is probably due to structural errors in the model introduced by the pilot point regularization scheme. It is concluded that maximum information and uncertainty reduction for constraining a groundwater flow model is obtained using an environmental tracer whose half-life is well matched to the range of transport times through the groundwater flow system. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  2. Extracellular domain shedding influences specific tumor uptake and organ distribution of the EGFR PET tracer 89Zr-imgatuzumab.

    PubMed

    Pool, Martin; Kol, Arjan; Lub-de Hooge, Marjolijn N; Gerdes, Christian A; de Jong, Steven; de Vries, Elisabeth G E; Terwisscha van Scheltinga, Anton G T

    2016-10-18

    Preclinical positron emission tomography (PET) imaging revealed a mismatch between in vivo epidermal growth factor receptor (EGFR) expression and EGFR antibody tracer tumor uptake. Shed EGFR ectodomain (sEGFR), which is present in cancer patient sera, can potentially bind tracer and therefore influence tracer kinetics. To optimize EGFR-PET, we examined the influence of sEGFR levels on tracer kinetics and tumor uptake of EGFR monoclonal antibody 89Zr-imgatuzumab in varying xenograft models. Human cancer cell lines A431 (EGFR overexpressing, epidermoid), A549 and H441 (both EGFR medium expressing, non-small cell lung cancer) were xenografted in mice. Xenografted mice received 10, 25 or 160 μg 89Zr-imgatuzumab, co-injected with equal doses 111In-IgG control. MicroPET scans were made 24, 72 and 144 h post injection, followed by biodistribution analysis. sEGFR levels in liver and plasma samples were determined by ELISA. 89Zr-imgatuzumab uptake in A431 tumors was highest (29.8 ± 5.4 %ID/g) in the 160 μg dose group. Contrary, highest uptake in A549 and H441 tumors was found at the lowest (10 μg) 89Zr-imgatuzumab dose. High 89Zr-imgatuzumab liver accumulation was found in A431 xenografted mice, which decreased with antibody dose increments. 89Zr-imgatuzumab liver uptake in A549 and H441 xenografted mice was low at all doses. sEGFR levels in liver and plasma of A431 bearing mice were up to 1000-fold higher than levels found in A549, H441 and non-tumor xenografted mice. 89Zr-imgatuzumab effectively visualizes EGFR-expressing tumors. High sEGFR levels can redirect 89Zr-imgatuzumab to the liver, in which case tumor visualization can be improved by increasing tracer antibody dose.

  3. Tracer-based quantification of individual frac discharge in single-well multiple-frac backflow: sensitivity study

    NASA Astrophysics Data System (ADS)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2014-05-01

    Within the deep-geothermal research project at GroßSchönebeck in the NE German Basin, targeting volcanic rocks (Lower Rotliegend) and siliciclastics (Upper Rotliegend) in the Lower Permian by means of a well doublet with several screening intervals between 3815 and 4247 m b.s.l., several artificial fractures with different geometric and hydraulic characteristics were created at each well, aiming to increase reservoir performance [1], [2]. It could not be told a priori which of the various fracturing treatments was to prove as most promising in terms of future reservoir productivity. At the intended-production well (GS-4), one large-area waterfrac was created in the low-permeability volcanic rocks, and two gel-proppant fractures in selected sandstone layers. Each fracturing treatment was accompanied by the injection of a water-dissolved tracer slug, followed by a defined volume of tracer-free ('chaser') fluid [3]. Each frac received a different species of a sulfonated aromatic acid salt, as a conservative water tracer. During subsequent backflow tests (either gas-based lifting, or production by means of a downhole submersible pump), each frac can contribute a certain (more or less constant) amount to the measured total discharge (also depending on whether and when each frac 'starts' contributing, and which effective aperture and area it actually 'manifests' during the process). Since these individual-frac discharge amounts cannot be measured directly, it was endeavoured to indirectly determine ('resolve') them from tracer signals as detectable in the overall backflow discharge. Therefore, we need to examine how these tracer signals depend on local discharge values and on local hydrogeologic parameters (matrix porosity, permeability distribution; frac transmissivity, thickness, effective area and aperture), and to what extent hydrogeological uncertainty will impede the inversion of local discharge values. To this end, a parameter sensitivity study was conducted on a simplified flow and tracer transport model (using FEOW and assuming Darcian flow within the matrix, Hagen-Poiseuille flow within the waterfrac, and either D or H-P flow within the gel-proppant fracs), whose main findings are: (1) late tracer signals are almost independent on matrix porosity, permeability distribution, frac area (length), thickness and effective aperture, while being highly sensitive to local discharge values; 'late' means a backflow or production volume at least fivefold the injected chaser volume; (2a) early tracer signals (concentration 'peak' intervals) may exhibit slight 'acceleration' and 'damping' with increasing matrix porosity or increasing frac aperture (a 'paradoxical' behaviour which is not really surprising for single-well 'push-then-backflow' tests, actually owing to flow-field dispersion[4]), and (2b) a non-monotonous response to varying frac area, being almost insensitive to frac area as long as the linear-flow regime prevails against the radial-flow regime (effects of the latter only becoming visible at very low frac areas); (2c) the effects of these various factors on early-time tracer signals are not unambiguously discernible from each other, and this ambiguity would persist even if frac-resolved (in-situ) discharge metering were feasible. For each of the three fracs (k=1,2,3), a 'type-curve' set Ck(Q,t) (parametrized by discharge values Q) can be generated. Since every frac received a different tracer, tracer signals measured within the overall backflow will differ from individual-frac type-curves by mere dilution (no 'superposition'). Type-curve dilution by factor Qk/Qtotal can be compared to measured tracer concentrations in the total discharge, ck(ti), (i = 1, ..., no. of tracer samplings). From a formal point of view, the unknown discharge values Qk can be determined as the solution of a linear optimization task subject to the constraint Q1 + Q2 + Q3 = Qtotal (the latter being a measured value). It is recommendable to perform 'optimization' manually, rather than by resorting to automated solutions provided by some linear programming software. The first items to inspect are the late-time height and slope of measured tracer signal 'tailings': their height yields a first approximation to dilution factors, and thus a first estimate for Qk, while late-time consistency of observed tailing slopes can be taken as indicative of the applicability of model presuppositions. To be noted, dilution factors associated with individual fracs can vary with time, since a steady-state discharge pattern might not be reached simultaneously at all fracs. The paper also discusses some reasons why early-time tracer signals are generally unsuited for frac discharge inversion. References: [1] Blöcher M G, Zimmermann G, Moeck I, Brandt W, Hassanzadegan A, Magri F (2010) 3D numerical modeling of hydrothermal processes during the lifetime of a deep geothermal reservoir. Geofluids, 10, 406-421. [2] Zimmermann G, Blöcher G, Reinicke A, Brandt W (2011) Rock specific hydraulic fracturing and matrix acidizing to enhance a geothermal system - Concepts and field results. Tectonophysics, 503, 146-154. [3] http://pangea.stanford.edu/ERE/pdf/IGAstandard/SGW/2007/ghergut.pdf [4] http://pangea.stanford.edu/ERE/pdf/IGAstandard/SGW/2013/Ghergut3.pdf ; ~Ghergut5.pdf Acknowledgements: Tracer tests at the GroßSchönebeck site were conducted with financial and operational support from the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) and from the Helmholtz Research Centre GeoForschungsZentrum (GFZ) Potsdam. Modelling work was conducted within the 'gebo' project ('Geothermal Energy and High-Performance Drilling', www.gebo-nds.de), funded by the Lower-Saxonian government and by Baker Hughes (Celle), Germany.

  4. Rejuvenating the Largest Treatment Wetland in Florida: Tracer Moment and Model Analysis of Wetland Hydraulic Performance

    NASA Astrophysics Data System (ADS)

    White, J. R.; Wang, H.; Jawitz, J. W.; Sees, M. D.

    2004-12-01

    The Orlando Easterly Wetland (OEW), the largest municipal treatment wetland in Florida, began operation in 1987 mainly for reducing nutrient loads in tertiary treated domestic wastewater produced by the city of Orlando. After more than ten years of operation, a decrease in total P removal effectiveness has occurred since 1999, even though the effluent concentration of the wetland has remained below the permitted limit of 0.2 mg/L,. Hydraulic inefficiency in the wetland, especially in the front-end cells of the north flow train, was identified as a primary cause of the reduced treatment effectiveness. In order to improve the hydraulic performance of the OEW and maintain its efficient phosphorus treatment, a rejuvenation program (including muck removal followed by re-vegetation) was initiated on the front-end cells of the north flow train in 2002. The effectiveness of this activity for the improvement of hydraulic performance was evaluated with a tracer test and subsequent moment and model analyses for the tracer resident time distribution (RTDs). Results were compared to similar tracer tests conducted prior to rejuvenation activities. The models included one-path tank-in-series (TIS), two-path TIS, one-dimensional transport with inflow and storage (OTIS), plug flow with dispersion (PFD), and plug flow with fractional dispersion (PFFD). The hydraulic performance was characterized by both wetland hydraulic efficiency and the spreading of tracers. The results demonstrated that the rejuvenation considerably improved the hydraulic performance in the restored area. Also presented is a comparison of the wetland response between both bromide and lithium tracers, and the determination of the complete moments of residence time distributions (RTD) in cell-network wetlands.

  5. PIT-tagged particle study of bed mobility in a Maine salmon river impacted by logging activities

    NASA Astrophysics Data System (ADS)

    Thompson, D. M.; Fixler, S. A.; Roberts, K. E.; McKenna, M.; Marshall, A. E.; Koenig, S.

    2017-12-01

    Presenting an interim report on a study on the Narraguagus River in Maine, which utilizes laser total stations cross-sectional surveys and tracking of passive integrated transponder (PIT) tags embedded in glass spheres to document changes in channel-bed characteristics associated with large wood (LW) additions and natural spawning activities. In 2016, work was initiated to monitor changes in bed elevation and sediment mobility with the addition of LW to the Narraguagus River as part of a restoration effort. Ten cross-sections, spaced 5-m apart, were established and surveyed with a laser total station in each of three different study reaches. The study sites include a control reach, a section with anticipated spawning activities and a site with ongoing LW placement. A grid of 200 glass spheres embedded with PIT tags, with twenty alternating 25-mm and 40-mm size particles equally spaced along each of the ten transects, were placed to serve as point sensors to detect sediment mobilization within each reach. In 2017, the site was revisited to determine if differences in PIT-tagged tracer particle mobilization reflect locations were LW was added and places where Atlantic salmon (Salmo salar) and sea lamprey (Petromyzon marinus) construct spawning redds. The positions of PIT-tagged tracer particles was recorded, but particles were not disturbed or uncovered to permit study of potential reworking of buried tracer particles the following year. Full tracer particle recovery will be determined in 2018 to determine if depths of tracer burial and changes in bed elevation vary among places near redds, LW and main channel locations. The data will be used to determine if salmon redds are preferentially located in either places with greater evidence of sediment reworking or alternatively in stable areas? The study will help determine the degree of bed disruption associated with spawning activities and whether LW placement encourages similar sediment mobilization processes.

  6. Methods for the Measurement of a Bacterial Enzyme Activity in Cell Lysates and Extracts

    PubMed Central

    Mendz, George; Hazell, Stuart

    1998-01-01

    The kinetic characteristics and regulation of aspartate carbamoyltransferase activity were studied in lysates and cell extracts of Helicobacter pylori by three diffirent methods. Nuclear magnetic resonance spectroscopy, radioactive tracer analysis, and spectrophotometry were employed in conjunction to identify the properties of the enzyme activity and to validate the results obtained with each assay. NMR spectroscopy was the most direct method to provide proof of ACTase activity; radioactive tracer analysis was the most sensitive technique and a microtitre-based colorimetric assay was the most cost-and time-efficient for large scale analyses. Freeze-thawing was adopted as the preferred method for cell lysis in studying enzyme activity in situ. This study showed the benefits of employing several different complementary methods to investigate bacterial enzyme activity. PMID:12734591

  7. Characterizing coarse bedload transport during floods with RFID and accelerometer tracers, in-stream RFID antennas and HEC-RAS modeling

    NASA Astrophysics Data System (ADS)

    Olinde, L.; Johnson, J. P.

    2013-12-01

    By monitoring the transport timing and distances of tracer grains in a steep mountains stream, we collected data that can constrain numerical bedload transport models considered for these systems. We captured bedload activity during a weeks-spanning snowmelt period in Reynolds Creek, Idaho by deploying Radio Frequency Identification (RFID) and accelerometer embedded tracers with in-stream stationary RFID antennas. During transport events, RFID dataloggers recorded the times when tracers passed over stationary antennas. The accelerometer tracers also logged x, y, z-axis accelerations every 10 minutes to identify times of motion and rest. After snowmelt flows receded, we found tracers with mobile antennas and surveyed their positions. We know the timing and tracer locations when accelerometer tracers were initially entrained, passed stationary antennas, and were finally deposited at the surveyed locations. The fraction of moving accelerometers over time correlates well with discharge. Comparisons of the transported tracer fraction between rising and falling limbs over multiple flood peaks suggest that some degree of clockwise hysteresis persisted during the snowmelt period. Additionally, we apply accelerometer transport durations and displacement distances to calculate virtual velocities over full tracer path lengths and over lengths between initial locations to stationary antennas as well as between stationary antennas to final positions. The accelerometer-based virtual velocities are significantly faster than those estimated from traditional tracer methods that estimate bedload transport durations by assuming threshold flow conditions. We also subsample the motion data to calculate how virtual velocities change over the measurement intervals. Regressions of these relations are in turn used to extrapolate virtual velocities at smaller sampling timescales. Minimum hop lengths are also evaluated for each accelerometer tracer. Finally, flow conditions during the snowmelt hydrograph are modeled over the 11 kilometers of surveyed stream by utilizing 1m airborne LiDAR and HEC-GeoRAS. Cross-sectional HEC-RAS results are used to estimate the spatial distribution of longitudinal shear velocities over the observed discharges. At final accelerometer tracer positions, we analyze the HEC-RAS generated flow conditions for each disentrainment discharge magnitude. The techniques developed here have the potential to link individual grain characteristics during floods to a range of time and length scales.

  8. Positron emission tomography imaging of CD105 expression in a rat myocardial infarction model with (64)Cu-NOTA-TRC105.

    PubMed

    Orbay, Hakan; Zhang, Yin; Valdovinos, Hector F; Song, Guoqing; Hernandez, Reinier; Theuer, Charles P; Hacker, Timothy A; Nickles, Robert J; Cai, Weibo

    2013-01-01

    Biological changes following myocardial infarction (MI) lead to increased secretion of angiogenic factors that subsequently stimulate the formation of new blood vessels as a compensatory mechanism to reverse ischemia. The goal of this study was to assess the role of CD105 expression during MI-induced angiogenesis by positron emission tomography (PET) imaging using (64)Cu-labeled TRC105, an anti-CD105 monoclonal antibody. MI was induced by ligation of the left anterior descending (LAD) artery in female rats. Echocardiography and (18)F-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET scans were performed on post-operative day 3 to confirm the presence of MI in the infarct group and intact heart in the sham group, respectively. Ischemia-induced angiogenesis was non-invasively monitored with (64)Cu-NOTA-TRC105 (an extensively validated PET tracer in our previous studies) PET on post-operative days 3, 10, and 17. Tracer uptake in the infarct zone was highest on day 3 following MI, which was significantly higher than that in the sham group (1.41 ± 0.45 %ID/g vs 0.57 ± 0.07 %ID/g; n=3, p<0.05). Subsequently, tracer uptake in the infarct zone decreased over time to the background level on day 17, whereas tracer uptake in the heart of sham rats remained low at all time points examined. Histopathology documented increased CD105 expression following MI, which corroborated in vivo findings. This study indicated that PET imaging of CD105 can be a useful tool for MI-related research, which can potentially improve MI patient management in the future upon clinical translation of the optimized PET tracers.

  9. Assessing antibody microarrays for space missions: effect of long-term storage, gamma radiation, and temperature shifts on printed and fluorescently labeled antibodies.

    PubMed

    de Diego-Castilla, Graciela; Cruz-Gil, Patricia; Mateo-Martí, Eva; Fernández-Calvo, Patricia; Rivas, Luis A; Parro, Víctor

    2011-10-01

    Antibody microarrays are becoming frequently used tools for analytical purposes. A key factor for optimal performance is the stability of the immobilized (capturing) antibodies as well as those that have been fluorescently labeled to achieve the immunological test (tracers). This is especially critical for long-distance transport, field testing, or planetary exploration. A number of different environmental stresses may affect the antibody integrity, such as dryness, sudden temperature shift cycles, or, as in the case of space science, exposure to large quantities of the highly penetrating gamma radiation. Here, we report on the effect of certain stabilizing solutions for long-term storage of printed antibody microarrays under different conditions. We tested the effect of gamma radiation on printed and freeze- or vacuum-dried fluorescent antibodies at working concentrations (tracer antibodies), as well as the effect of multiple cycles of sudden and prolonged temperature shifts on the stability of fluorescently labeled tracer antibody cocktails. Our results show that (i) antibody microarrays are stable at room temperature when printed on stabilizing spotting solutions for at least 6 months, (ii) lyophilized and vacuum-dried fluorescently labeled tracer antibodies are stable for more than 9 months of sudden temperature shift cycles (-20°C to 25°C and 50°C), and (iii) both printed and freeze- or vacuum-dried fluorescent tracer antibodies are stable after several-fold excess of the dose of gamma radiation expected during a mission to Mars. Although different antibodies may exhibit different susceptibilities, we conclude that, in general, antibodies are suitable for use in planetary exploration purposes if they are properly treated and stored with the use of stabilizing substances.

  10. Using dual-domain advective-transport simulation to reconcile multiple-tracer ages and estimate dual-porosity transport parameters

    NASA Astrophysics Data System (ADS)

    Sanford, Ward E.; Niel Plummer, L.; Casile, Gerolamo; Busenberg, Ed; Nelms, David L.; Schlosser, Peter

    2017-06-01

    Dual-domain transport is an alternative conceptual and mathematical paradigm to advection-dispersion for describing the movement of dissolved constituents in groundwater. Here we test the use of a dual-domain algorithm combined with advective pathline tracking to help reconcile environmental tracer concentrations measured in springs within the Shenandoah Valley, USA. The approach also allows for the estimation of the three dual-domain parameters: mobile porosity, immobile porosity, and a domain exchange rate constant. Concentrations of CFC-113, SF6, 3H, and 3He were measured at 28 springs emanating from carbonate rocks. The different tracers give three different mean composite piston-flow ages for all the springs that vary from 5 to 18 years. Here we compare four algorithms that interpret the tracer concentrations in terms of groundwater age: piston flow, old-fraction mixing, advective-flow path modeling, and dual-domain modeling. Whereas the second two algorithms made slight improvements over piston flow at reconciling the disparate piston-flow age estimates, the dual-domain algorithm gave a very marked improvement. Optimal values for the three transport parameters were also obtained, although the immobile porosity value was not well constrained. Parameter correlation and sensitivities were calculated to help quantify the uncertainty. Although some correlation exists between the three parameters being estimated, a watershed simulation of a pollutant breakthrough to a local stream illustrates that the estimated transport parameters can still substantially help to constrain and predict the nature and timing of solute transport. The combined use of multiple environmental tracers with this dual-domain approach could be applicable in a wide variety of fractured-rock settings.

  11. Quantification of the vertical translocation rate of soil solid-phase material by the magnetic tracer method

    NASA Astrophysics Data System (ADS)

    Zhidkin, A. P.; Gennadiev, A. N.

    2016-07-01

    Approaches to the quantification of the vertical translocation rate of soil solid-phase material by the magnetic tracer method have been developed; the tracer penetration depth and rate have been determined, as well as the radial distribution of the tracer in chernozems (Chernozems) and dark gray forest soils (Luvisols) of Belgorod oblast under natural steppe and forest vegetation and in arable lands under agricultural use of different durations. It has been found that the penetration depth of spherical magnetic particles (SMPs) during their 150-year-occurrence in soils of a forest plot is 68 cm under forest, 58 cm on a 100-year old plowland, and only 49 cm on a 150-year-old plowland. In the chernozems of the steppe plot, the penetration depth of SMPs exceeds the studied depth of 70 cm both under natural vegetation and on the plowlands. The penetration rates of SMPs deep into the soil vary significantly among the key plots: 0.92-1.32 mm/year on the forest plot and 1.47-1.63 mm/year on the steppe plot, probably because of the more active recent turbation activity of soil animals.

  12. Tracer Methods for Characterizing Fracture Creation in Engineered Geothermal Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rose, Peter; Harris, Joel

    2014-05-08

    The aim of this proposal is to develop, through novel high-temperature-tracing approaches, three technologies for characterizing fracture creation within Engineered Geothermal Systems (EGS). The objective of a first task is to identify, develop and demonstrate adsorbing tracers for characterizing interwell reservoir-rock surface areas and fracture spacing. The objective of a second task is to develop and demonstrate a methodology for measuring fracture surface areas adjacent to single wells. The objective of a third task is to design, fabricate and test an instrument that makes use of tracers for measuring fluid flow between newly created fractures and wellbores. In one methodmore » of deployment, it will be used to identify qualitatively which fractures were activated during a hydraulic stimulation experiment. In a second method of deployment, it will serve to measure quantitatively the rate of fluid flowing from one or more activated fracture during a production test following a hydraulic stimulation.« less

  13. Biodistribution of I-123-iodo-amphetamine in man

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bischof-Delaloye, A.; HUngerbuhler, J.P.; Regli, F.

    1984-01-01

    Biodistribution and in vivo kinetics of iodo-amphetamine were studied in 18 patients (13 CVC, 3 metastases, 2 seizures). After 10 min of complete rest 5 mCi of N-isopropyl-p-(123I)-iodo-amphetamine(p,5n) were injected and 5, 15, 30, 45, 60, 90, 120 min blood samples taken. Whole body tracer distribution was studied with a dual head camera 30-60 and 90-120 min post-injection, at 24h in 3, at 48h in 2 patients. 3 days urinary elimination was measured in 2 patients. Brain, lung, liver, thyroid and bladder counts of anterior and posterior views were averaged and expressed as percent of WB activity. Brain ECT wasmore » performed 60 min p.i. in all, after 2h in 2 patients. Plasma activity decreased first with a fast, than with a slower component (mean Ti/2:5 and 60min respectively), than it became stable or increased slightly. 30-60min p.i. the brain concentrated an average of 5.6% of WB activity, the lungs 30.7%, the liver 19.2% and the thyroid 1%. Brain and thyroid activity did not significantly change during the second interval (6.3 and 1.1% respectively), lung activity decreased (24.7%), liver (22.7%) and bladder activity (1 to 2.3%) increased. 3 days urinary elimination was 6.3 and 7.9% of the injected dose respectively. In contrast with the findings in the primate no eye activity could be detected even at 24 and 48h. Intracerebral tracer distribution was similar on the 1 and 2h ECT. These data confirm the stability of brain activity observed in the animal between 30 and 120min after injection, but without showing any eye uptake of the tracer. Brain ECT with I-123-iodo-amphetamine may be performed during this interval under stable conditions in what concerns the absolute uptake as well as intracerebral distribution of the tracer.« less

  14. 13C Pathway Analysis for the Role of Formate in Electricity Generation by Shewanella Oneidensis MR-1 Using Lactate in Microbial Fuel Cells

    PubMed Central

    Luo, Shuai; Guo, Weihua; H. Nealson, Kenneth; Feng, Xueyang; He, Zhen

    2016-01-01

    Microbial fuel cell (MFC) is a promising technology for direct electricity generation from organics by microorganisms. The type of electron donors fed into MFCs affects the electrical performance, and mechanistic understanding of such effects is important to optimize the MFC performance. In this study, we used a model organism in MFCs, Shewanella oneidensis MR-1, and 13C pathway analysis to investigate the role of formate in electricity generation and the related microbial metabolism. Our results indicated a synergistic effect of formate and lactate on electricity generation, and extra formate addition on the original lactate resulted in more electrical output than using formate or lactate as a sole electron donor. Based on the 13C tracer analysis, we discovered decoupled cell growth and electricity generation in S. oneidensis MR-1 during co-utilization of lactate and formate (i.e., while the lactate was mainly metabolized to support the cell growth, the formate was oxidized to release electrons for higher electricity generation). To our best knowledge, this is the first time that 13C tracer analysis was applied to study microbial metabolism in MFCs and it was demonstrated to be a valuable tool to understand the metabolic pathways affected by electron donors in the selected electrochemically-active microorganisms. PMID:26868848

  15. Radiosynthesis and validation of (±)-[18F]-3-fluoro-2-hydroxypropionate ([18F]-FLac) as a PET tracer of lactate to monitor MCT1-dependent lactate uptake in tumors.

    PubMed

    Van Hée, Vincent F; Labar, Daniel; Dehon, Gwenaël; Grasso, Debora; Grégoire, Vincent; Muccioli, Giulio G; Frédérick, Raphaël; Sonveaux, Pierre

    2017-04-11

    Cancers develop metabolic strategies to cope with their microenvironment often characterized by hypoxia, limited nutrient bioavailability and exposure to anticancer treatments. Among these strategies, the metabolic symbiosis based on the exchange of lactate between hypoxic/glycolytic cancer cells that convert glucose to lactate and oxidative cancer cells that preferentially use lactate as an oxidative fuel optimizes the bioavailability of glucose to hypoxic cancer cells. This metabolic cooperation has been described in various human cancers and can provide resistance to anti-angiogenic therapies. It depends on the expression and activity of monocarboxylate transporters (MCTs) at the cell membrane. MCT4 is the main facilitator of lactate export by glycolytic cancer cells, and MCT1 is adapted for lactate uptake by oxidative cancer cells. While MCT1 inhibitor AZD3965 is currently tested in phase I clinical trials and other inhibitors of lactate metabolism have been developed for anticancer therapy, predicting and monitoring a response to the inhibition of lactate uptake is still an unmet clinical need. Here, we report the synthesis, evaluation and in vivo validation of (±)-[18F]-3-fluoro-2-hydroxypropionate ([18F]-FLac) as a tracer of lactate for positron emission tomography. [18F]-FLac offers the possibility to monitor MCT1-dependent lactate uptake and inhibition in tumors in vivo.

  16. Radiosynthesis and validation of (±)-[18F]-3-fluoro-2-hydroxypropionate ([18F]-FLac) as a PET tracer of lactate to monitor MCT1-dependent lactate uptake in tumors

    PubMed Central

    Van Hée, Vincent F.; Labar, Daniel; Dehon, Gwenaël; Grasso, Debora; Grégoire, Vincent; Muccioli, Giulio G

    2017-01-01

    Cancers develop metabolic strategies to cope with their microenvironment often characterized by hypoxia, limited nutrient bioavailability and exposure to anticancer treatments. Among these strategies, the metabolic symbiosis based on the exchange of lactate between hypoxic/glycolytic cancer cells that convert glucose to lactate and oxidative cancer cells that preferentially use lactate as an oxidative fuel optimizes the bioavailability of glucose to hypoxic cancer cells. This metabolic cooperation has been described in various human cancers and can provide resistance to anti-angiogenic therapies. It depends on the expression and activity of monocarboxylate transporters (MCTs) at the cell membrane. MCT4 is the main facilitator of lactate export by glycolytic cancer cells, and MCT1 is adapted for lactate uptake by oxidative cancer cells. While MCT1 inhibitor AZD3965 is currently tested in phase I clinical trials and other inhibitors of lactate metabolism have been developed for anticancer therapy, predicting and monitoring a response to the inhibition of lactate uptake is still an unmet clinical need. Here, we report the synthesis, evaluation and in vivo validation of (±)-[18F]-3-fluoro-2-hydroxypropionate ([18F]-FLac) as a tracer of lactate for positron emission tomography. [18F]-FLac offers the possibility to monitor MCT1-dependent lactate uptake and inhibition in tumors in vivo. PMID:28107190

  17. Substance P and acetylcholine are co-localized in the pathway mediating mucociliary activity in Rana pipiens.

    PubMed

    Hernández, C J; Ortíz, T; Rosa, C; Foster, K; Tyagi, M; Lugo, N; Albrecht, R; Chinapen, S

    2007-04-01

    Mucociliary activity is an important clearance mechanism in the respiratory system of air breathing vertebrates. Substance P (SP) and acetylcholine play a key role in the stimulation of the mucociliary transport in the frog palate. In this study, retrograde neuronal tracing was combined with immunocytochemistry for SP and choline acetyl transferase (ChAT) in the trigeminal ganglion and for neurokinin-1 receptor (NK1R) in the palate of Rana pipiens. The cells of origin of the palatine nerve were identified in the trigeminal ganglion using the retrograde tracer Fluorogold (FG). Optimal labeling of FG cells in the trigeminal ganglion was obtained at 96 h of exposure. Immunoflorescent shows that SP and acetylcholine are co-localized in 92% of the cells labeled with FG in the trigeminal ganglion. NK1 receptors were found in the membrane of epithelial and goblet cells of the palate. Ultrastructural study of the palate showed axonal-like endings with vesicles in connection with epithelial and goblet cells. These results further support the concerted action of both neurotransmitters in the regulation of mucociliary activity in the frog palate.

  18. Accurate Measurement of Postprandial Glucose Turnover: Why Is It Difficult and How Can It Be Done (Relatively) Simply?

    PubMed Central

    Toffolo, Gianna; Cobelli, Claudio

    2016-01-01

    Fasting hyperglycemia occurs when an excessive rate of endogenous glucose production (EGP) is not accompanied by an adequate compensatory increase in the rate of glucose disappearance (Rd). The situation following food ingestion is more complex as the amount of glucose that reaches the circulation for disposal is a function of the systemic rate of appearance of the ingested glucose (referred to as the rate of meal appearance [Rameal]), the pattern and degree of suppression of EGP, and the rapidity of stimulation of the Rd. In an effort to measure these processes, Steele et al. proposed what has come to be referred to as the dual-tracer method in which the ingested glucose is labeled with one tracer while a second tracer is infused intravenously at a constant rate. Unfortunately, subsequent studies have shown that although this approach is technically simple, the marked changes in plasma specific activity or the tracer-to-tracee ratio, if stable tracers are used, introduce a substantial error in the calculation of Rameal, EGP, and Rd, thereby leading to incorrect and at times misleading results. This Perspective discusses the causes of these so-called “nonsteady-state” errors and how they can be avoided by the use of the triple-tracer approach. PMID:27208180

  19. Bioturbation, advection, and diffusion of a conserved tracer in a laboratory flume

    NASA Astrophysics Data System (ADS)

    Work, P. A.; Moore, P. R.; Reible, D. D.

    2002-06-01

    Laboratory experiments indicating the relative influences of advection, diffusion, and bioturbation on transport of NaCl tracer between a stream and streambed are described. Data were collected in a recirculating flume housing a box filled with test sediments. Peclet numbers ranged from 0 to 1.5. Sediment components included a medium sand (d50 = 0.31 mm), kaolinite, and topsoil. Lumbriculus variegatus were introduced as bioturbators. Conductivity probes were employed to document the flux of the tracer solution out of the bed. Measurements are compared to one-dimensional effective diffusion models assuming one or two horizontal sediment layers. These simple models provide a good indication of tracer half-life in the bed if a suitable effective diffusion coefficient is chosen but underpredict initial flux and overpredict flux at long times. Organism activity was limited to the upper reaches of the sediment test box but eventually exerts a secondary influence on flux from deeper regions.

  20. In vivo imaging of sulfotransferases

    DOEpatents

    Barrio, Jorge R; Kepe, Vladimir; Small, Gary W; Satyamurthy, Nagichettiar

    2013-02-12

    Radiolabeled tracers for sulfotransferases (SULTs), their synthesis, and their use are provided. Included are substituted phenols, naphthols, coumarins, and flavones radiolabeled with .sup.18F, .sup.123I, .sup.124I, .sup.125I, or .sup.11C. Also provided are in vivo techniques for using these and other tracers as analytical and diagnostic tools to study sulfotransferase distribution and activity, in health and disease, and to evaluate therapeutic interventions.

  1. Coagulation effect on the activity size distributions of long lived radon progeny aerosols and its application to atmospheric residence time estimation techniques.

    PubMed

    Anand, S; Mayya, Y S

    2015-03-01

    The long lived naturally occurring radon progeny species in the atmosphere, namely (210)Pb, (210)Bi and (210)Po, have been used as important tracers for understanding the atmospheric mixing processes and estimating aerosol residence times. Several observations in the past have shown that the activity size distribution of these species peaks at larger particle sizes as compared to the short lived radon progeny species - an effect that has been attributed to the process of coagulation of the background aerosols to which they are attached. To address this issue, a mathematical equation is derived for the activity-size distribution of tracer species by formulating a generalized distribution function for the number of tracer atoms present in coagulating background particles in the presence of radioactive decay and removal. A set of these equations is numerically solved for the progeny chain using Fuchs coagulation kernel combined with a realistic steady-state aerosol size spectrum that includes nucleation, accumulation and coarse mode components. The important findings are: (i) larger shifts in the modal sizes of (210)Pb and (210)Po at higher aerosol concentrations such as that found in certain Asian urban regions (ii) enrichment of tracer specific activity on particles as compared to that predicted by pure attachment laws (iii) sharp decline of daughter-to-parent activity ratios for decreasing particle sizes. The implication of the results to size-fractionated residence time estimation techniques is highlighted. A coagulation corrected graphical approach is presented for estimating the residence times from the size-segregated activity ratios of (210)Bi and (210)Po with respect to (210)Pb. The discrepancy between the residence times predicted by conventional formula and the coagulation corrected approach for specified activity ratios increases at higher atmospheric aerosol number concentrations (>10(10) #/m(3)) for smaller sizes (<1 μm). The results are further discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. The NETPET Score: Combining FDG and Somatostatin Receptor Imaging for Optimal Management of Patients with Metastatic Well-Differentiated Neuroendocrine Tumors.

    PubMed

    Hindié, Elif

    2017-01-01

    Neuroendocrine tumors (NET) are often metastatic at the time of diagnosis. Metastatic well-differentiated (G1/G2) NET may display a wide range of behaviors, ranging from indolent to aggressive, even within apparently homogeneous categories. Thus, selecting the optimal treatment strategy is a challenging task. Somatostatin receptor imaging (SRI) is the standard molecular imaging technique for well-differentiated NET. When performed with 68 Ga-labeled somatostatin analogs (SRI-PET), it offers exquisite sensitivity for disease staging. SRI is also a prerequisite for using targeted radionuclide therapy (e.g. 177 Lu-DOTATATE). 18F-FDG imaging has traditionally been reserved for staging poorly-differentiated G3 neuroendocrine carcinomas. However, recent data showed that FDG imaging has prognostic value in patients with well-differentiated NET: high uptake was associated with an increased risk of early progression while low uptake suggested an indolent tumor. In this issue of the Journal, Chan and colleagues propose a grading system where the results from the combined reading of SRI-PET and FDG-PET are reported as a single parameter, the "NETPET" score. While the scoring system still needs validation, it is clear that time has come to think about FDG and SRI in metastatic NET not as competitors but as complementary imaging modalities. Dual-tracer imaging can be viewed as a way to characterize disease phenotype in the whole-body. Moving from the prognostic value of dual-tracer imaging to a tool that allows for individualized management would require prospective trials. This editorial will argue that dual-tracer FDG-PET and SRI-PET might influence management of patients with well-differentiated metastatic NET and help selecting between different therapy options.

  3. How young water fractions can delineate travel time distributions in contrasting catchments

    NASA Astrophysics Data System (ADS)

    Lutz, Stefanie; Zink, Matthias; Merz, Ralf

    2017-04-01

    Travel time distributions (TTDs) are crucial descriptors of flow and transport processes in catchments. Tracking fluxes of environmental tracers such as stable water isotopes offers a practicable method to determine TTDs. The mean transit time (MTT) is the most commonly reported statistic of TTDs; however, MTT assessments are prone to large aggregation biases resulting from spatial heterogeneity and non-stationarity in real-world catchments. Recently, the young water fraction (Fyw) has been introduced as a more robust statistic that can be derived from seasonal tracer cycles. In this study, we aimed at improving the assessment of TTDs by using Fyw as additional information in lumped isotope models. First, we calculated Fyw from monthly δ18O-samples for 24 contrasting sub-catchments in a meso-scale catchment (3300 km2). Fyw ranged from 0.01 to 0.27 (mean= 0.11) and was not significantly correlated with catchment characteristics (e.g., mean slope, catchment area, and baseflow index) apart from the dominant soil type. Second, assuming gamma-shaped TTDs, we determined time-invariant TTDs for each sub-catchment by optimization of lumped isotope models using the convolution integral method. Whereas multiple optimization runs for the same sub-catchment showed a wide range of TTD parameters, the use of Fyw as additional information allowed constraining this range and thus improving the assessment of MTTs. Hence, the best model fit to observed isotope data might not be the desired solution, as the resulting TTD might define a young water fraction non-consistent with the tracer-cycle based Fyw. Given that the latter is a robust descriptor of fast-flow contribution, isotope models should instead aim at accurately describing both Fyw and the isotope time series in order to improve our understanding of flow and transport in catchments.

  4. Modelling and scale-up of chemical flooding: First annual report for the period October 1985-September 1986

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Lake, L.W.; Sepehrnoori, K.

    1987-07-01

    This report consists of three parts. Part A describes the development of our chemical flood simulator UTCHEM during the past year, simulation studies, and physical property modelling and experiments. Part B is a report on the optimization and vectorization of UTCHEM on our Cray supercomputer to speed it up. Part C describes our use of UTCHEM to investigate the use of tracers for interwell reservoir tests. Part A of this Annual Report consists of five sections. In the first section, we give a general description of the simulator and recent changes in it along with a test case for amore » slightly compressible fluid. In the second section, we describe the major changes which were needed to add gel and alkaline reactions and give preliminary simulation results for these processes. In the third section, comparisons with a surfactant pilot field test are given. In the fourth section, process scaleup and design simulations are given and also our recent mesh refinement results. In the fifth section, experimental results and associated physical property modelling studies are reported. Part B gives our results on the speedup of UTCHEM on a Cray supercomputer. Depending on the size of the problem, this speedup factor was at least tenfold and resulted from a combination of a faster solver, vectorization, and code optimization. Part C describes our use of UTCHEM for field tracer studies and gives the results of a comparison with field tracer data on the same field (Big Muddy) as was simulated and compared with the surfactant pilot reported in section 3 of Part A. 120 figs., 37 tabs.« less

  5. Comparison of short-lived medical isotopes activation by laser thin target induced protons and conventional cyclotron proton beams

    NASA Astrophysics Data System (ADS)

    Murray, Joseph; Dudnikova, Galina; Liu, Tung-Chang; Papadopoulos, Dennis; Sagdeev, Roald; Su, J. J.; UMD MicroPET Team

    2014-10-01

    Production diagnostic or therapeutic nuclear medicines are either by nuclear reactors or by ion accelerators. In general, diagnostic nuclear radioisotopes have a very short half-life varying from tens of minutes for PET tracers and few hours for SPECT tracers. Thus supplies of PET and SPECT radiotracers are limited by regional production facilities. For example 18F-fluorodeoxyglucose (FDG) is the most desired tracer for positron emission tomography because its 110 minutes half-life is sufficient long for transport from production facilities to nearby users. From nuclear activation to completing image taking must be done within 4 hours. Decentralized production of diagnostic radioisotopes will be idea to make high specific activity radiotracers available to researches and clinicians. 11 C, 13 N, 15 O and 18 F can be produced in the energy range from 10-20 MeV by protons. Protons of energies up to tens of MeV generated by intense laser interacting with hydrogen containing targets have been demonstrated by many groups in the past decade. We use 2D PIC code for proton acceleration, Geant4 Monte Carlo code for nuclei activation to compare the yields and specific activities of short-lived isotopes produced by cyclotron proton beams and laser driven protons.

  6. Optimized Unlike-Pair Interactions for Water-Carbon Dioxide Mixtures described by the SPC/E and EPM2 Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlcek, Lukas; Chialvo, Ariel A; Cole, David

    The unlike- pair interaction parameters for the SPC/E- EPM2 models have been optimized to reproduce the mutual solubility of water and carbon dioxide at the conditions of liquid- supercritical fluid phase equilibria. An efficient global optimization of the parameters is achieved through an implementation of the coupling parameter approach, adapted to phase equilibria calculations in the Gibbs ensemble, that explicitly corrects for the over- polarization of the SPC/E water molecule in the non- polar CO2 environments. The resulting H2O- CO2 force field reproduces accurately the available experimental solubilities at the two fluid phases in equilibria as well as the correspondingmore » species tracer diffusion coefficients.« less

  7. Real-time 4D electrical resistivity imaging of tracer transport within an energically stimulated fracture zone

    NASA Astrophysics Data System (ADS)

    Johnson, T. C.

    2016-12-01

    Hydraulic fracture stimulation is used extensively in the subsurface energy sector to improve access between energy bearing formations and production boreholes. However, large uncertainties exist concerning the location and extent of stimulated fractures, and concerning the behavior of flow within those fractures. This uncertainty often results in significant risks, including induced seismicity and contamination of potable groundwater aquifers. Time-lapse electrical resistivity tomography (ERT) is a proven method of imaging fluid flow within fracture networks, by imaging the change in bulk conductivity induced by the presence of an electrically anomalous tracer within the fracture. In this work we demonstrate characterization and flow monitoring of a stimulated fracture using real-time four-dimensional ERT imaging within an unsaturated rhyolite formation. After stimulation, a conductive tracer was injected into the fracture zone. ERT survey data were continuously and autonomously collected, pre-processed on site, submitted to an off-site high performance computing system for inversion, and returned to the field for inspection. Surveys were collected at approximately 12 minute intervals. Data transmission and inversion required approximately 2 minutes per survey. The time-lapse imaging results show the dominant flow-paths within the stimulated fracture zone, thereby revealing the location and extent of the fracture, and the behavior of tracer flow within the fracture. Ultimately real-time imaging will enable site operators to better understand stimulation operations, and control post-stimulation reservoir operations for optimal performance and environmental protection.

  8. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasmamore » measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.« less

  9. Vorapaxar and optimal aspirin dose: The FDA outlook.

    PubMed

    Serebruany, Victor L; Fortmann, Seth D; Kim, Moo Hyun

    2016-01-15

    Vorapaxar, a novel thrombin PAR-1 inhibitor, approved for post-myocardial infarction, and peripheral artery disease indications has been tested in 2 major clinical trials. In the successful TRA2P, antecedent aspirin (ASA) has been used in 94% of patients, and in failed TRACER in over 96% of patients. However, both trial publications were silent on the impact of ASA dose on clinical outcomes after voraparax. We determined which ASA dose range should be used in combination with voraparax based on the TRA2P and TRACER secondary FDA review. The data suggest that for both voraparax trials, younger patients, males, and diabetics received higher ASA doses. The interactions between voraparax efficacy and ASA dose ≥ 300 mg was marginally significant by Cox regressions for TRA2P (CI=1.00-1.61; p=0.048) and strongly trended in TRACER (CI=0.98-1.47; p=0.073). Bleeding rates were overall slightly higher with voraparax than with placebo, and were the highest in patients receiving ASA dosages ≥ 300 mg. However, there were no interactions between ASA dose and GUSTO moderate/severe bleeding. In conclusion, the efficacy of voraparax in TRA2P and TRACER, was slightly worse while bleeding was substantially worse with the higher over 300 mg/day of ASA dosages. Voraparax label should recommend ASA daily use in 75 to 100mg range for concomitant use. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Modeling and experimental design for metabolic flux analysis of lysine-producing Corynebacteria by mass spectrometry.

    PubMed

    Wittmann, C; Heinzle, E

    2001-04-01

    Experimental design of (13)C-tracer studies for metabolic flux analysis with mass spectrometric determination of labeling patterns was performed for the central metabolism of Corynebacterium glutamicum comprising various flux scenarios. Ratio measurement of mass isotopomer pools of Corynebacterium products lysine, alanine, and trehalose is sufficient to quantify the flux partitioning ratios (i) between glycolysis and pentose phosphate pathways (Phi(PPP)), (ii) between the split pathways in the lysine biosynthesis (Phi(DH)), (iii) at the pyruvate node (Phi(PC)), and reversibilities of (iv) glucose 6-phosphate isomerase (zeta(PGI)), (v) at the pyruvate node (zeta(PC/PEPCK)), and (vi) of transaldolase and transketolases in the PPP. Weighted sensitivities for flux parameters were derived from partial derivatives to quantitatively evaluate experimental approaches and predict precision for estimated flux parameters. Deviation of intensity ratios from ideal values of 1 was used as weighting function. Weighted flux sensitivities can be used to identify optimal type and degree of tracer labeling or potential intensity ratios to be measured. Experimental design for lysine-producing strain C. glutamicum MH 20-22B (Marx et al., Biotechnol. Bioeng. 49, 111-129, 1996) and various potential mutants with different alterations in the flux pattern showed that specific tracer labelings are optimal to quantify a certain flux parameter uninfluenced by the overall flux situation. Identified substrates of choice are [1-(13)C]glucose for the estimation of Phi(PPP) and zeta(PGI) and a 1 : 1 mixture of [U-(12)C/U-(13)C]glucose for the determination of zeta(PC/PEPCK). Phi(PC) can be quantified by feeding [4-(13)C]glucose or [U-(12)C/U-(13)C]glucose (1 : 1), whereas Phi(DH) is accessible via [4-(13)C]glucose. The sensitivity for the quantification of a certain flux parameter can be influenced by superposition through other flux parameters in the network, but substrate and measured mass isotopomers of choice remain the same. In special cases, reduced labeling degree of the tracer substrate can increase the precision of flux analysis. Enhanced precision and flux information can be achieved via multiply labeled substrates. The presented approach can be applied for effective experimental design of (13)C tracer studies for metabolic flux analysis. Intensity ratios of other products such as glutamate, valine, phenylalanine, and riboflavin also sensitively reflect flux parameters, which underlines the great potential of mass spectrometry for flux analysis. Copyright 2001 Academic Press.

  11. Reconstruction of Atmospheric Tracer Releases with Optimal Resolution Features: Concentration Data Assimilation

    NASA Astrophysics Data System (ADS)

    Singh, Sarvesh Kumar; Turbelin, Gregory; Issartel, Jean-Pierre; Kumar, Pramod; Feiz, Amir Ali

    2015-04-01

    The fast growing urbanization, industrialization and military developments increase the risk towards the human environment and ecology. This is realized in several past mortality incidents, for instance, Chernobyl nuclear explosion (Ukraine), Bhopal gas leak (India), Fukushima-Daichi radionuclide release (Japan), etc. To reduce the threat and exposure to the hazardous contaminants, a fast and preliminary identification of unknown releases is required by the responsible authorities for the emergency preparedness and air quality analysis. Often, an early detection of such contaminants is pursued by a distributed sensor network. However, identifying the origin and strength of unknown releases following the sensor reported concentrations is a challenging task. This requires an optimal strategy to integrate the measured concentrations with the predictions given by the atmospheric dispersion models. This is an inverse problem. The measured concentrations are insufficient and atmospheric dispersion models suffer from inaccuracy due to the lack of process understanding, turbulence uncertainties, etc. These lead to a loss of information in the reconstruction process and thus, affect the resolution, stability and uniqueness of the retrieved source. An additional well known issue is the numerical artifact arisen at the measurement locations due to the strong concentration gradient and dissipative nature of the concentration. Thus, assimilation techniques are desired which can lead to an optimal retrieval of the unknown releases. In general, this is facilitated within the Bayesian inference and optimization framework with a suitable choice of a priori information, regularization constraints, measurement and background error statistics. An inversion technique is introduced here for an optimal reconstruction of unknown releases using limited concentration measurements. This is based on adjoint representation of the source-receptor relationship and utilization of a weight function which exhibits a priori information about the unknown releases apparent to the monitoring network. The properties of the weight function provide an optimal data resolution and model resolution to the retrieved source estimates. The retrieved source estimates are proved theoretically to be stable against the random measurement errors and their reliability can be interpreted in terms of the distribution of the weight functions. Further, the same framework can be extended for the identification of the point type releases by utilizing the maximum of the retrieved source estimates. The inversion technique has been evaluated with the several diffusion experiments, like, Idaho low wind diffusion experiment (1974), IIT Delhi tracer experiment (1991), European Tracer Experiment (1994), Fusion Field Trials (2007), etc. In case of point release experiments, the source parameters are mostly retrieved close to the true source parameters with least error. Primarily, the proposed technique overcomes two major difficulties incurred in the source reconstruction: (i) The initialization of the source parameters as required by the optimization based techniques. The converged solution depends on their initialization. (ii) The statistical knowledge about the measurement and background errors as required by the Bayesian inference based techniques. These are hypothetically assumed in case of no prior knowledge.

  12. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    NASA Astrophysics Data System (ADS)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  13. An Integrated Approach to Characterizing Bypassed Oil in Heterogeneous and Fractured Reservoirs Using Partitioning Tracers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akhil Datta-Gupta

    2006-12-31

    We explore the use of efficient streamline-based simulation approaches for modeling partitioning interwell tracer tests in hydrocarbon reservoirs. Specifically, we utilize the unique features of streamline models to develop an efficient approach for interpretation and history matching of field tracer response. A critical aspect here is the underdetermined and highly ill-posed nature of the associated inverse problems. We have investigated the relative merits of the traditional history matching ('amplitude inversion') and a novel travel time inversion in terms of robustness of the method and convergence behavior of the solution. We show that the traditional amplitude inversion is orders of magnitudemore » more non-linear and the solution here is likely to get trapped in local minimum, leading to inadequate history match. The proposed travel time inversion is shown to be extremely efficient and robust for practical field applications. The streamline approach is generalized to model water injection in naturally fractured reservoirs through the use of a dual media approach. The fractures and matrix are treated as separate continua that are connected through a transfer function, as in conventional finite difference simulators for modeling fractured systems. A detailed comparison with a commercial finite difference simulator shows very good agreement. Furthermore, an examination of the scaling behavior of the computation time indicates that the streamline approach is likely to result in significant savings for large-scale field applications. We also propose a novel approach to history matching finite-difference models that combines the advantage of the streamline models with the versatility of finite-difference simulation. In our approach, we utilize the streamline-derived sensitivities to facilitate history matching during finite-difference simulation. The use of finite-difference model allows us to account for detailed process physics and compressibility effects. The approach is very fast and avoids much of the subjective judgments and time-consuming trial-and-errors associated with manual history matching. We demonstrate the power and utility of our approach using a synthetic example and two field examples. We have also explored the use of a finite difference reservoir simulator, UTCHEM, for field-scale design and optimization of partitioning interwell tracer tests. The finite-difference model allows us to include detailed physics associated with reactive tracer transport, particularly those related with transverse and cross-streamline mechanisms. We have investigated the potential use of downhole tracer samplers and also the use of natural tracers for the design of partitioning tracer tests. Finally, we discuss several alternative ways of using partitioning interwell tracer tests (PITTs) in oil fields for the calculation of oil saturation, swept pore volume and sweep efficiency, and assess the accuracy of such tests under a variety of reservoir conditions.« less

  14. Metrology conditions for thin layer activation in wear and corrosion studies

    NASA Astrophysics Data System (ADS)

    Lacroix, O.; Sauvage, T.; Blondiaux, G.; Racolta, P. M.; Popa-Simil, L.; Alexandreanu, B.

    1996-02-01

    Thin Layer Activation (TLA) is an ion beam technique. This method consists of an accelerated ion bombardment of the surface of interest of a machine part subjected to wear. Radioactive tracers are created by nuclear reactions in a well defined volume of material. Loss of material owing to wear, corrosion or abrasion phenomena is characterized by monitoring the resulting changes in radioactivity. For the industrial application of this method, special attention has been paid during irradiation to the range of activated thickness, yields and activation homogeneity and to on-line radioactivity measurements. There are two basic methods for measuring the material loss by TLA technique. One of them is based on remanant radioactivity measurements using a previously obtained calibration curve. The second is based on measuring the increasing radioactivity in the lubricant due to suspended wear particles. In this paper, we have chosen to present some calibration curves for both proton and deuteron irradiation of Fe, Cr, Cu, Ti and Ni samples. Thickness ranges are indicated and intrinsic error checking and calculational procedures are also presented. The article ends with a review of some typical experiments involving running-in programme optimization and lubricants certifying procedures.

  15. Estimates of tracer-based piston-flow ages of groundwater from selected sites: National Water-Quality Assessment Program, 2006-2010

    USGS Publications Warehouse

    Shapiro, Stephanie D.; Plummer, Niel; Busenberg, Eurybiades; Widman, Peggy K.; Casile, Gerolamo C.; Wayland, Julian E.; Runkle, Donna L.

    2012-01-01

    Piston-flow age dates were interpreted from measured concentrations of environmental tracers from 812 National Water-Quality Assessment (NAWQA) Program groundwater sites from 27 Study Units across the United States. The tracers of interest include chlorofluorocarbons (CFCs), sulfur hexafluoride (SF6), and tritium/helium-3 (3H/3He). Tracer data compiled for this analysis were collected from 2006 to 2010 from groundwater wells in NAWQA studies, including: * Land-Use Studies (LUS, shallow wells, usually monitoring wells, located in recharge areas under dominant land-use settings), * Major-Aquifer Studies (MAS, wells, usually domestic supply wells, located in principal aquifers and representing the shallow drinking water supply), * Flow System Studies (FSS, networks of clustered wells located along a flowpath extending from a recharge zone to a discharge zone, preferably a shallow stream) associated with Land-Use Studies, and * Reference wells (wells representing groundwater minimally impacted by anthropogenic activities) also associated with Land-Use Studies. Tracer data were evaluated using documented methods and are presented as aqueous concentrations, equivalent atmospheric concentrations (for CFCs and SF6), and tracer-based piston-flow ages. Selected ancillary data, such as redox data, well-construction data, and major dissolved-gas (N2, O2, Ar, CH4, and CO2) data, also are presented. Recharge temperature was inferred using climate data (approximated by mean annual air temperature plus 1°C [MAAT +1°C]) as well as major dissolved-gas data (N2-Ar-based) where available. The N2-Ar-based temperatures showed significantly more variation than the climate-based data, as well as the effects of denitrification and degassing resulting from reducing conditions. The N2-Ar-based temperatures were colder than the climate-based temperatures in networks where recharge was limited to the winter months when evapotranspiration was reduced. The tracer-based piston-flow ages compiled in this report are provided as a consistent means of reporting the tracer data. The tracer-based piston-flow ages may provide an initial interpretation of age in cases in which mixing is minimal and may aid in developing a basic conceptualization of groundwater age in an aquifer. These interpretations are based on the assumption that tracer transport is by advection only and that no mixing occurs. In addition, it is assumed that other uncertainties are minimized, including tracer degradation, sorption, contamination, or fractionation, and that terrigenic (natural) sources of tracers, and spatially variable atmospheric tracer concentrations are constrained.

  16. Dual-isotope PET using positron-gamma emitters.

    PubMed

    Andreyev, A; Celler, A

    2011-07-21

    Positron emission tomography (PET) is widely recognized as a highly effective functional imaging modality. Unfortunately, standard PET cannot be used for dual-isotope imaging (which would allow for simultaneous investigation of two different biological processes), because positron-electron annihilation products from different tracers are indistinguishable in terms of energy. Methods that have been proposed for dual-isotope PET rely on differences in half-lives of the participating isotopes; these approaches, however, require making assumptions concerning kinetic behavior of the tracers and may not lead to optimal results. In this paper we propose a novel approach for dual-isotope PET and investigate its performance using GATE simulations. Our method requires one of the two radioactive isotopes to be a pure positron emitter and the second isotope to emit an additional high-energy gamma in a cascade simultaneously with positron emission. Detection of this auxiliary prompt gamma in coincidence with the annihilation event allows us to identify the corresponding 511 keV photon pair as originating from the same isotope. Two list-mode datasets are created: a primary dataset that contains all detected 511 keV photon pairs from both isotopes, and a second, tagged (much smaller) dataset that contains only those PET events for which a coincident prompt gamma has also been detected. An image reconstructed from the tagged dataset reflects the distribution of the second positron-gamma radiotracer and serves as a prior for the reconstruction of the primary dataset. Our preliminary simulation study with partially overlapping (18)F/(22)Na and (18)F/(60)Cu radiotracer distributions showed that in these two cases the dual-isotope PET method allowed for separation of the two activity distributions and recovered total activities with relative errors of about 5%.

  17. New techniques for positron emission tomography in the study of human neurological disorders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1993-01-01

    This progress report describes accomplishments of four programs. The four programs are entitled (1) Faster,simpler processing of positron-computing precursors: New physicochemical approaches, (2) Novel solid phase reagents and methods to improve radiosynthesis and isotope production, (3) Quantitative evaluation of the extraction of information from PET images, and (4) Optimization of tracer kinetic methods for radioligand studies in PET.

  18. The effect of renal failure on 18F-FDG uptake: a theoretic assessment.

    PubMed

    Laffon, Eric; Cazeau, Anne-Laure; Monet, Antoine; de Clermont, Henri; Fernandez, Philippe; Marthan, Roger; Ducassou, Dominique

    2008-12-01

    This work addresses the issue of using (18)F-FDG PET in patients with renal failure. A model analysis has been developed to compare tissue (18)F-FDG uptake in a patient who has normal renal function with uptake in a theoretic limiting case that assumes tracer plasma decay is tracer physical decay and is trapped irreversibly. This comparison has allowed us to propose, in the limiting case, that the usually injected activity be lowered by a factor of 3. We also proposed that the PET static acquisition be obtained at about 160 min after tracer injection. These 2 proposals were aimed at obtaining a similar patient radiation dose and similar tissue (18)F-FDG uptake. In patients with arbitrary renal failure (i.e., between the 2 extremes of normal function and the theoretic limiting case), we propose that the injected activity be lowered (without exceeding a factor of 3) and that the acquisition be started between 45 and 160 min after tracer injection, depending on the severity of renal failure. Furthermore, the model also shows that the more severe the renal failure is, the more overestimated is the standardized uptake value, unless the renal failure indirectly impairs tissue sensitivity to insulin and hence glucose metabolism.

  19. A mathematical approach towards simulating a realistic tissue activity curve of 64Cu-ATSM for the purpose of sub-target volume delineation in radiotherapy

    NASA Astrophysics Data System (ADS)

    Dalah, E.; Bradley, D.; Nisbet, A.

    2010-07-01

    One unique feature of positron emission tomography (PET) is that it allows measurements of regional tracer concentration in hypoxic tumour-bearing tissue, supporting the need for accurate radiotherapy treatment planning. Generally the data are taken over multiple time frames, in the form of tissue activity curves (TACs), providing an indication of the presence of hypoxia, the degree of oxygen perfusion, vascular geometry and hypoxia fraction. In order to understand such a complicated phenomenon a number of theoretical studies have attempted to describe tracer uptake in tissue cells. More recently, a novel computerized reaction diffusion equation method developed by Kelly and Brady has allowed simulation of the realistic TACs of 18F-FMISO, with representation of physiological oxygen heterogeneity and tracer kinetics. We present a refinement to the work of Kelly and Brady, with a particular interest in simulating TACs of the most promising hypoxia selective tracer, 64Cu-ATSM, demonstrating its potential role in tumour sub-volume delineation for radiotherapy treatment planning. Simulation results have demonstrated the high contrast of imaging using ATSM, with a tumour to blood ratio ranging 2.24-4.1. Similarly, results of tumour sub-volumes generated using three different thresholding methods were all well correlated.

  20. Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging of macrophages in large vessel vasculitis: Current status and future prospects.

    PubMed

    Jiemy, William Febry; Heeringa, Peter; Kamps, Jan A A M; van der Laken, Conny J; Slart, Riemer H J A; Brouwer, Elisabeth

    2018-05-03

    Macrophages are key players in the pathogenesis of large-vessel vasculitis (LVV) and may serve as a target for diagnostic imaging of LVV. The radiotracer, 18 F-FDG has proven to be useful in the diagnosis of giant cell arteritis (GCA), a form of LVV. Although uptake of 18 F-FDG is high in activated macrophages, it is not a specific radiotracer as its uptake is high in any proliferating cell and other activated immune cells resulting in high non-specific background radioactivity especially in aging and atherosclerotic vessels which dramatically lowers the diagnostic accuracy. Evidence also exists that the sensitivity of 18 F-FDG PET drops in patients upon glucocorticoid treatment. Therefore, there is a clinical need for more specific radiotracers in imaging GCA to improve diagnostic accuracy. Numerous clinically established and newly developed macrophage targeted radiotracers for oncological and inflammatory diseases can potentially be utilized for LVV imaging. These tracers are more target specific and therefore may provide lower background radioactivity, higher diagnostic accuracy and the ability to assess treatment effectiveness. However, current knowledge regarding macrophage subsets in LVV lesions is limited. Further understanding regarding macrophage subsets in vasculitis lesion is needed for better selection of tracers and new targets for tracer development. This review summarizes the development of macrophage targeted tracers in the last decade and the potential application of macrophage targeted tracers currently used in other inflammatory diseases in imaging LVV. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Observations of coarse sediment movements on the mixed beach of the Elwha Delta, Washington

    USGS Publications Warehouse

    Miller, I.M.; Warrick, J.A.; Morgan, C.

    2011-01-01

    Mixed beaches, with poorly sorted grains of multiple sizes, are a common and globally distributed shoreline type. Despite this, rates and mechanisms of sediment transport on mixed beaches are poorly understood. A series of tracer deployments using native clasts implanted with Radio Frequency Identifier (RFID) tags was used to develop a better understanding of sediment transport directions and magnitudes on the mixed grain-size beach of the Elwha River delta. Using tracer samples selected to match the distribution of the coarse fraction on the beach we find that all grain sizes, up to large cobbles (128-256 mm), were mobile under most measured wave conditions and move in relationship to the direction of the alongshore component of wave energy as estimated by incident breaking wave angles. In locations where the breaking wave is normal to the shoreline we find that tracers move in both alongshore directions with approximately equal frequency. In locations where breaking waves are oblique to the shoreline we find that alongshore transport is more unidirectional and tracers can approach average velocities of 100. m/day under winter wave conditions. We use the tracer cloud to estimate the beach active width, the mobile layer depth and sediment velocity. Our results suggest that, while sediment velocity increases under increased incident wave angles, the active layer depth and width decrease, reducing sediment flux at the site with the more oblique breaking waves. This result is contrary to what is suggested by traditional wave energy transport models of alongshore sediment transport. ?? 2011 Elsevier B.V.

  2. High contrast tumor imaging with radio-labeled antibody Fab fragments tailored for optimized pharmacokinetics via PASylation

    PubMed Central

    Mendler, Claudia T; Friedrich, Lars; Laitinen, Iina; Schlapschy, Martin; Schwaiger, Markus; Wester, Hans-Jürgen; Skerra, Arne

    2015-01-01

    Although antigen-binding fragments (Fabs) of antibodies constitute established tracers for in vivo radiodiagnostics, their functionality is hampered by a very short circulation half-life. PASylation, the genetic fusion with a long, conformationally disordered amino acid chain comprising Pro, Ala and Ser, provides a convenient way to expand protein size and, consequently, retard renal filtration. Humanized αHER2 and αCD20 Fabs were systematically fused with 100 to 600 PAS residues and produced in E. coli. Cytofluorimetric titration analysis on tumor cell lines confirmed that antigen-binding activities of the parental antibodies were retained. The radio-iodinated PASylated Fabs were studied by positron emission tomography (PET) imaging and biodistribution analysis in mouse tumor xenograft models. While the unmodified αHER2 and αCD20 Fabs showed weak tumor uptake (0.8% and 0.2% ID/g, respectively; 24 h p.i.) tumor-associated radioactivity was boosted with increasing PAS length (up to 9 and 26-fold, respectively), approaching an optimum for Fab-PAS400. Remarkably, 6- and 5-fold higher tumor-to-blood ratios compared with the unmodified Fabs were measured in the biodistribution analysis (48 h p.i.) for αHER2 Fab-PAS100 and Fab-PAS200, respectively. These findings were confirmed by PET studies, showing high imaging contrast in line with tumor-to-blood ratios of 12.2 and 5.7 (24 h p.i.) for αHER2 Fab-PAS100 and Fab-PAS200. Even stronger tumor signals were obtained with the corresponding αCD20 Fabs, both in PET imaging and biodistribution analysis, with an uptake of 2.8% ID/g for Fab-PAS100 vs. 0.24% ID/g for the unmodified Fab. Hence, by engineering Fabs via PASylation, plasma half-life can be tailored to significantly improve tracer uptake and tumor contrast, thus optimally matching reagent/target interactions. PMID:25484039

  3. High contrast tumor imaging with radio-labeled antibody Fab fragments tailored for optimized pharmacokinetics via PASylation.

    PubMed

    Mendler, Claudia T; Friedrich, Lars; Laitinen, Iina; Schlapschy, Martin; Schwaiger, Markus; Wester, Hans-Jürgen; Skerra, Arne

    2015-01-01

    Although antigen-binding fragments (Fabs) of antibodies constitute established tracers for in vivo radiodiagnostics, their functionality is hampered by a very short circulation half-life. PASylation, the genetic fusion with a long, conformationally disordered amino acid chain comprising Pro, Ala and Ser, provides a convenient way to expand protein size and, consequently, retard renal filtration. Humanized αHER2 and αCD20 Fabs were systematically fused with 100 to 600 PAS residues and produced in E. coli. Cytofluorimetric titration analysis on tumor cell lines confirmed that antigen-binding activities of the parental antibodies were retained. The radio-iodinated PASylated Fabs were studied by positron emission tomography (PET) imaging and biodistribution analysis in mouse tumor xenograft models. While the unmodified αHER2 and αCD20 Fabs showed weak tumor uptake (0.8% and 0.2% ID/g, respectively; 24 h p.i.) tumor-associated radioactivity was boosted with increasing PAS length (up to 9 and 26-fold, respectively), approaching an optimum for Fab-PAS400. Remarkably, 6- and 5-fold higher tumor-to-blood ratios compared with the unmodified Fabs were measured in the biodistribution analysis (48 h p.i.) for αHER2 Fab-PAS100 and Fab-PAS200, respectively. These findings were confirmed by PET studies, showing high imaging contrast in line with tumor-to-blood ratios of 12.2 and 5.7 (24 h p.i.) for αHER2 Fab-PAS100 and Fab-PAS200. Even stronger tumor signals were obtained with the corresponding αCD20 Fabs, both in PET imaging and biodistribution analysis, with an uptake of 2.8% ID/g for Fab-PAS100 vs. 0.24% ID/g for the unmodified Fab. Hence, by engineering Fabs via PASylation, plasma half-life can be tailored to significantly improve tracer uptake and tumor contrast, thus optimally matching reagent/target interactions.

  4. Is (18)F-FDG a surrogate tracer to measure tumor hypoxia? Comparison with the hypoxic tracer (14)C-EF3 in animal tumor models.

    PubMed

    Christian, Nicolas; Deheneffe, Stéphanie; Bol, Anne; De Bast, Marc; Labar, Daniel; Lee, John A; Grégoire, Vincent

    2010-11-01

    Fluorodeoxyglucose (FDG) has been reported as a surrogate tracer to measure tumor hypoxia with positron emission tomography (PET). The hypothesis is that there is an increased uptake of FDG under hypoxic conditions secondary to enhanced glycolysis, compensating the hypoxia-induced loss of cellular energy production. Several studies have already addressed this issue, some with conflicting results. This study aimed to compare the tracers (14)C-EF3 and (18)F-FDG to detect hypoxia in mouse tumor models. C3H, tumor-bearing mice (FSAII and SCCVII tumors) were injected iv with (14)C-EF3, and 1h later with (18)F-FDG. Using a specifically designed immobilization device with fiducial markers, PET (Mosaic®, Philips) images were acquired 1h after the FDG injection. After imaging, the device containing mouse was frozen, transversally sliced and imaged with autoradiography (AR) (FLA-5100, Fujifilm) to obtain high resolution images of the (18)F-FDG distribution within the tumor area. After a 48-h delay allowing for (18)F decay a second AR was performed to image (14)C-EF3 distribution. AR images were aligned to reconstruct the full 3D tumor volume, and were compared with the PET images. Image segmentation with threshold-based methods was applied on both AR and PET images to derive various tracer activity volumes. The matching index DSI (dice similarity index) was then computed. The comparison was performed under normoxic (ambient air, FSAII: n=4, SCCVII, n=5) and under hypoxic conditions (10% O(2) breathing, SCCVII: n=4). On AR, under both ambient air and hypoxic conditions, there was a decreasing similarity between (14)C-EF3 and FDG with higher activity sub-volumes. Under normoxic conditions, when comparing the 10% of tumor voxels with the highest (18)F-FDG or (14)C-EF3 activity, a DSI of 0.24 and 0.20 was found for FSAII and SCCVII, respectively. Under hypoxic conditions, a DSI of 0.36 was observed for SCCVII tumors. When comparing the (14)C-EF3 distribution in AR with the corresponding (18)F-FDG-PET images, the DSI reached values of 0.26, 0.22 and 0.21 for FSAII and SCCVII under normoxia and SCCVII under hypoxia, respectively. This study showed that FDG is not a good surrogate tracer for tumor hypoxia under either ambient or hypoxic conditions. Only specific hypoxia tracers should be used to measure tumor hypoxia. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Activation of reciprocal pathways between arcuate nucleus and ventrolateral periaqueductal gray during electroacupuncture: involvement of VGLUT3

    PubMed Central

    Guo, Zhi-Ling; Longhurst, John C.

    2010-01-01

    Electroacupuncture (EA) at the Jianshi-Neiguan acupoints (P5-P6, overlying the median nerve) attenuates sympathoexcitatory responses through activation of the arcuate nucleus (ARC) and ventrolateral periaqueductal gray (vlPAG). Activation of the ARC or vlPAG respectively leads to neuronal excitation of the both nuclei during EA. However, direct projections between these two nuclei that could participate in central neural processing during EA have not been identified. The vesicular glutamate transporter 3 (VGLUT3) marks glutamatergic neurons. Thus, the present study evaluated direct neuronal projections between the ARC and vlPAG during EA, focusing on neurons containing VGLUT3. Seven to ten days after unilateral microinjection of a rodamine-conjugated microsphere retrograde tracer (100 nl) into the vlPAG or ARC, rats were subjected to EA or served as a sham-operated control. Low frequency (2 Hz) EA was performed bilaterally for 30 min at the P5-P6 acupoints. Perikarya containing the microsphere tracer were found in the ARC and vlPAG of both groups. Compared to controls (needle placement without electrical stimulation), c-Fos immunoreactivity and neurons double-labeled with c-Fos, an immediate early gene and the tracer were increased significantly in the ARC and vlPAG of EA-treated rats (both P<0.01). Moreover, some neurons were triple-labeled with c-Fos, the retrograde tracer and VGLUT3 in the two nuclei following EA stimulation (P<0.01, both nuclei). These results suggest that direct reciprocal projections between the ARC and vlPAG are available to participate in prolonged modulation by EA of sympathetic activity and that VGLUT3-containing neurons are an important neuronal phenotype involved in this process. PMID:20836994

  6. Turnover Time in the Hyporheic Zone as Assessed by 3D Geophysical Imaging

    NASA Astrophysics Data System (ADS)

    Kohler, B.; Hall, R. O., Jr.; Carr, B.

    2017-12-01

    The hyporheic zone (HZ) is a region of interest in stream hydrology and ecology, however, its heterogeneity across small spatial scales and difficulty to directly measure has hampered researchers' efforts to understand its specific contribution to processes such as solute transport and nutrient retention and removal. In recent years researchers have combined geophysical imaging, such as electrical resistivity tomography (ERT), with tracer additions to directly measure exchange between surface waters and the HZ without physically disrupting natural subsurface flow paths. We conducted constant-rate tracer additions in two small headwater mountain streams while collecting 3D ERT images downstream before, during, after each tracer addition to yield spatially comprehensive models of solute exchange with the HZ through time. From our 3D HZ models, we calculated the active volume of the HZ, normalized to the maximum measured size, for each time step giving a breakthrough curve of tracer abundance in the HZ through time. We then described the tracer's turnover time in the HZ by applying exponential and power decay models to the breakthrough curve of HZ volume in a similar manner that one would for a tracer breakthrough curve in surface waters. Our models suggest that the flushing of solutes from the HZ exhibit multi-domain behavior, where advective and diffusive exchange between HZ and surface waters occur simultaneously and operate at distinctly different rates.

  7. Gastric activity studies using a magnetic tracer.

    PubMed

    Cordova-Fraga, T; Bernal-Alvarado, J J; Gutierrez-Juarez, G; Sosa, M; Vargas-Luna, M

    2004-10-01

    A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29.3+/-6.4 years and body mass index 26.0+/-4.8 kg m(-2). Magnetite (Fe3O4) particles with diameters from 75 to 125 microm were used as magnetic tracers, which were mixed in 250 ml of yogurt in concentrations from 2 to 5 g. Signals were registered by using a high speed 3 axis fluxgate digital magnetometer and processed to determine the relaxation of the magnetic tracers by fitting a first-order exponential function to the data, a mean relaxation constant K = 116+/-40 s(-1) was obtained. Also, an average gastric peristaltic frequency was measured; a value of 3.2+/-0.3 cpm was determined.

  8. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodman, N.D., E-mail: n.d.woodman@soton.ac.uk; Rees-White, T.C.; Stringfellow, A.M.

    2015-04-15

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictionsmore » about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study.« less

  9. Linear regression techniques for use in the EC tracer method of secondary organic aerosol estimation

    NASA Astrophysics Data System (ADS)

    Saylor, Rick D.; Edgerton, Eric S.; Hartsell, Benjamin E.

    A variety of linear regression techniques and simple slope estimators are evaluated for use in the elemental carbon (EC) tracer method of secondary organic carbon (OC) estimation. Linear regression techniques based on ordinary least squares are not suitable for situations where measurement uncertainties exist in both regressed variables. In the past, regression based on the method of Deming [1943. Statistical Adjustment of Data. Wiley, London] has been the preferred choice for EC tracer method parameter estimation. In agreement with Chu [2005. Stable estimate of primary OC/EC ratios in the EC tracer method. Atmospheric Environment 39, 1383-1392], we find that in the limited case where primary non-combustion OC (OC non-comb) is assumed to be zero, the ratio of averages (ROA) approach provides a stable and reliable estimate of the primary OC-EC ratio, (OC/EC) pri. In contrast with Chu [2005. Stable estimate of primary OC/EC ratios in the EC tracer method. Atmospheric Environment 39, 1383-1392], however, we find that the optimal use of Deming regression (and the more general York et al. [2004. Unified equations for the slope, intercept, and standard errors of the best straight line. American Journal of Physics 72, 367-375] regression) provides excellent results as well. For the more typical case where OC non-comb is allowed to obtain a non-zero value, we find that regression based on the method of York is the preferred choice for EC tracer method parameter estimation. In the York regression technique, detailed information on uncertainties in the measurement of OC and EC is used to improve the linear best fit to the given data. If only limited information is available on the relative uncertainties of OC and EC, then Deming regression should be used. On the other hand, use of ROA in the estimation of secondary OC, and thus the assumption of a zero OC non-comb value, generally leads to an overestimation of the contribution of secondary OC to total measured OC.

  10. A Comparative Study of the Hypoxia PET Tracers [{sup 18}F]HX4, [{sup 18}F]FAZA, and [{sup 18}F]FMISO in a Preclinical Tumor Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peeters, Sarah G.J.A., E-mail: sarah.peeters@maastrichtuniversity.nl; Zegers, Catharina M.L.; Lieuwes, Natasja G.

    Purpose: Several individual clinical and preclinical studies have shown the possibility of evaluating tumor hypoxia by using noninvasive positron emission tomography (PET). The current study compared 3 hypoxia PET tracers frequently used in the clinic, [{sup 18}F]FMISO, [{sup 18}F]FAZA, and [{sup 18}F]HX4, in a preclinical tumor model. Tracer uptake was evaluated for the optimal time point for imaging, tumor-to-blood ratios (TBR), spatial reproducibility, and sensitivity to oxygen modification. Methods and Materials: PET/computed tomography (CT) images of rhabdomyosarcoma R1-bearing WAG/Rij rats were acquired at multiple time points post injection (p.i.) with one of the hypoxia tracers. TBR values were calculated, andmore » reproducibility was investigated by voxel-to-voxel analysis, represented as correlation coefficients (R) or Dice similarity coefficient of the high-uptake volume. Tumor oxygen modifications were induced by exposure to either carbogen/nicotinamide treatment or 7% oxygen breathing. Results: TBR was stabilized and maximal at 2 hours p.i. for [{sup 18}F]FAZA (4.0 ± 0.5) and at 3 hours p.i. for [{sup 18}F]HX4 (7.2 ± 0.7), whereas [{sup 18}F]FMISO showed a constant increasing TBR (9.0 ± 0.8 at 6 hours p.i.). High spatial reproducibility was observed by voxel-to-voxel comparisons and Dice similarity coefficient calculations on the 30% highest uptake volume for both [{sup 18}F]FMISO (R = 0.86; Dice coefficient = 0.76) and [{sup 18}F]HX4 (R = 0.76; Dice coefficient = 0.70), whereas [{sup 18}F]FAZA was less reproducible (R = 0.52; Dice coefficient = 0.49). Modifying the hypoxic fraction resulted in enhanced mean standardized uptake values for both [{sup 18}F]HX4 and [{sup 18}F]FAZA upon 7% oxygen breathing. Only [{sup 18}F]FMISO uptake was found to be reversible upon exposure to nicotinamide and carbogen. Conclusions: This study indicates that each tracer has its own strengths and, depending on the question to be answered, a different tracer can be put forward.« less

  11. A new approach to tracer transport analysis: From fracture systems to strongly heterogeneous porous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsang, Chin-Fu

    Many current development and utilization of groundwater resources include a study of their flow and transport properties. These properties are needed in evaluating possible changes in groundwater quality and potential transport of hazardous solutes through the groundwater system. Investigation of transport properties of fractured rocks is an active area of research. Most of the current approaches to the study of flow and transport in fractured rocks cannot be easily used for analysis of tracer transport field data. A new approach is proposed based on a detailed study of transport through a fracture of variable aperture. This is a two-dimensional stronglymore » heterogeneous permeable system. It is suggested that tracer breakthrough curves can be analyzed based on an aperture or permeability probability distribution function that characterizes the tracer flow through the fracture. The results are extended to a multi-fracture system and can be equally applied to a strongly heterogeneous porous medium. Finally, the need for multi-point or line and areal tracer injection and observation tests is indicated as a way to avoid the sensitive dependence of point measurements on local permeability variability. 30 refs., 15 figs.« less

  12. Biodistribution and radiation dosimetry in healthy volunteers of a novel tumour-specific probe for PET/CT imaging: BAY 85-8050.

    PubMed

    Smolarz, Kamilla; Krause, Bernd Joachim; Graner, Frank Philipp; Wagner, Franziska Martina; Wester, Hans-Jürgen; Sell, Tina; Bacher-Stier, Claudia; Fels, Lüder; Dinkelborg, Ludger; Schwaiger, Markus

    2013-12-01

    Novel tracers for the diagnosis of malignant disease with PET and PET/CT are being developed as the most commonly used (18)F deoxyglucose (FDG) tracer shows certain limitations. Employing radioactively labelled glutamate derivatives for specific imaging of the truncated citrate cycle potentially allows more specific tumour imaging. Radiation dosimetry of the novel tracer BAY 85-8050, a glutamate derivative, was calculated and the effective dose (ED) was compared with that of FDG. Five healthy volunteers were included in the study. Attenuation-corrected whole-body PET/CT scans were performed from 0 to 90 min, at 120 and at 240 min after injection of 305.0 ± 17.6 MBq of BAY 85-8050. Organs with moderate to high uptake at any of the imaging time points were used as source organs. Total activity in each organ at each time point was measured. Time-activity curves (TAC) were determined for the whole body and all source organs. The resulting TACs were fitted to exponential equations and accumulated activities were determined. OLINDA/EXM software was used to calculate individual organ doses and the whole-body ED from the acquired data. Uptake of the tracer was highest in the kidneys due to renal excretion of the tracer, followed by the pancreas, heart wall and osteogenic cells. The mean organ doses were: kidneys 38.4 ± 11.2 μSv/MBq, pancreas 23.2 ± 3.8 μSv/MBq, heart wall 17.4 ± 4.1 μSv/MBq, and osteogenic cells 13.6 ± 3.5 μSv/MBq. The calculated ED was 8.9 ± 1.5 μSv/MBq. Based on the distribution and dose estimates, the calculated radiation dose of BAY 85-8050 is 2.67 ± 0.45 mSv at a patient dose of 300 MBq, which compares favourably with the radiation dose of FDG (5.7 mSv).

  13. Optimization of transmission scan duration for 15O PET study with sequential dual tracer administration using N-index.

    PubMed

    Kudomi, Nobuyuki; Watabe, Hiroshi; Hayashi, Takuya; Oka, Hisashi; Miyake, Yoshinori; Iida, Hidehiro

    2010-06-01

    Cerebral blood flow (CBF), oxygen extraction fraction (OEF) and cerebral metabolic rate of O(2) (CMRO(2)) can be quantified by PET with the administration of H (2) (15) O and (15)O(2). Recently, a shortening in the duration of these measurements was achieved by the sequential administration of dual tracers of (15)O(2) and H (2) (15) O with PET acquisition and integration method (DARG method). A transmission scan is generally required for correcting photon attenuation in advance of PET scan. Although the DARG method can shorten the total study duration to around 30 min, the transmission scan duration has not been optimized and has possibility to shorten its duration. Our aim of this study was to determine the optimal duration for the transmission scan. We introduced 'N-index', which estimates the noise level on an image obtained by subtracting two statistically independent and physiologically equivalent images. The relationship between noise on functional images and duration of the transmission scan was investigated by N-index. We performed phantom studies to test whether the N-index reflects the pixel noise in a PET image. We also estimated the noise level by the N-index on CBF, OEF and CMRO(2) images from DARG method in clinical patients, and investigated an optimal true count of the transmission scan. We found tight correlation between pixel noise and N-index in the phantom study. By investigating relationship between the transmission scan duration and N-index value for the functional images by DARG method, we revealed that the transmission data with true counts of more than 40 Mcounts results in CBF, OEF, and CMRO(2) images of reasonable quantitative accuracy and quality. The present study suggests that further shortening of DARG measurement is possible by abridging the transmission scan. The N-index could be used to determine the optimal measurement condition when examining the quality of image.

  14. Bringing physiology into PET of the liver.

    PubMed

    Keiding, Susanne

    2012-03-01

    Several physiologic features make interpretation of PET studies of liver physiology an exciting challenge. As with other organs, hepatic tracer kinetics using PET is quantified by dynamic recording of the liver after the administration of a radioactive tracer, with measurements of time-activity curves in the blood supply. However, the liver receives blood from both the portal vein and the hepatic artery, with the peak of the portal vein time-activity curve being delayed and dispersed compared with that of the hepatic artery. The use of a flow-weighted dual-input time-activity curve is of importance for the estimation of hepatic blood perfusion through initial dynamic PET recording. The portal vein is inaccessible in humans, and methods of estimating the dual-input time-activity curve without portal vein measurements are being developed. Such methods are used to estimate regional hepatic blood perfusion, for example, by means of the initial part of a dynamic (18)F-FDG PET/CT recording. Later, steady-state hepatic metabolism can be assessed using only the arterial input, provided that neither the tracer nor its metabolites are irreversibly trapped in the prehepatic splanchnic area within the acquisition period. This is used in studies of regulation of hepatic metabolism of, for example, (18)F-FDG and (11)C-palmitate.

  15. Long-term mesocosm experiments to investigate microbial degradation of fluorescent tracers

    NASA Astrophysics Data System (ADS)

    Fernández-Pascual, Elena; Zaman, Sameera; Lang, Friederike; Lange, Jens

    2017-04-01

    Uranine (UR) and sulforhodamine B (SRB) are two of the most commonly used fluorescent tracers in hydrology. Their suitability to be used as ideal tracers has been discussed since they might interact with the soil or become degraded. However, these properties have recently served to mimic processes of sorption and degradation of pollutants. The present study attempts to investigate to what extent UR and SRB could be used to imitate such processes in environments where saturation conditions are variable and the presence of plants might play an important role. For this purpose, both tracers were applied to 36 small mesocosms filled with a layer of 10 cm of gravel and 30 cm of sand in which 6 types of treatments, with 3 replicates each, were implemented based on the presence of two species of wetland plants (Typha latifolia and Phalaris arundinacea) and two types of hydrological conditions (saturated and unsaturated). The entire experiment lasted 10 months, during which two injections of equal concentration of tracers were performed. The first months served to ensure the adaptability of the plants and to achieve stationary conditions in the system. Water and sediment samples were collected weekly after the second injection while plants were measured at the end of the experiment distinguishing between roots and aerial parts. Mass balances of the tracers were combined with excitation emission matrix fluorescence spectroscopy (EEMS) to characterize dissolved organic matter in the water and soil. Degradation was quantified by subtracting the non-degraded tracer fraction (sorption and plant uptake) and the remaining non-degraded mass in the water from the tracer mass injected. Results revealed that most of the SRB accumulated in the sand in agreement with its sorption affinity, while UR was mainly found in the pore water. Both tracers showed more degradation in the treatments with plants than the controls. Overall, UR exhibited higher degradation than SRB. Differences between plant species were not found for UR, whereas SRB showed more degradation with Phalaris than with Typha. The alternation of oxic and anoxic conditions in the unsaturated treatments increased the degradation of both tracers, especially SRB. Two components were identified by parallel factor analysis of the EEMS in addition to the UR, one humic-like associated with biological activity (C1) and one humic-like of terrestrial origin (C3). A high positive correlation (Spearman's rho = 0.81, p < 0.0001) between C1 and UR suggested a probable link, in which the increase of UR would lead to an increase of C1. This hypothesis was supported by the results from the controls, where UR exhibited the highest values of C1 while it was absent with SRB. This suggested a possible association of UR with microbial activity, which is in agreement with the high overall degradation rates found for UR. Further research is needed to confirm these results, but we see the combination of EEMS with tracer mass analysis as a promising way to provide additional information on processes of sorption and degradation of contaminants.

  16. Tracer level radiochemistry to clinical dose preparation of (177)Lu-labeled cyclic RGD peptide dimer.

    PubMed

    Chakraborty, Sudipta; Sarma, H D; Vimalnath, K V; Pillai, M R A

    2013-10-01

    Integrin αvβ3 plays a significant role in angiogenesis during tumor growth and metastasis, and is a receptor for the extracellular matrix proteins with the exposed arginine(R)-glycine(G)-aspartic acid(D) tripeptide sequence. The over-expression of integrin αvβ3 during tumor growth and metastasis presents an interesting molecular target for both early detection and treatment of rapidly growing solid tumors. Considering the advantages of (177)Lu for targeted radiotherapy and enhanced tumor targeting capability of cyclic RGD peptide dimer, an attempt has been made to optimize the protocol for the preparation of clinical dose of (177)Lu labeled DOTA-E[c(RGDfK)]2 (E=Glutamic acid, f=phenyl alanine, K=lysine) as a potential agent for targeted tumor therapy. (177)Lu was produced by thermal neutron bombardment on enriched Lu2O3 (82% in (176)Lu) target at a flux of 1 × 10(14) n/cm(2).s for 21 d. Therapeutic dose of (177)Lu-DOTA-E[c(RGDfK)]2 (7.4GBq) was prepared by adding the aqueous solution of the ligand and (177)LuCl3 to 0.1M NH4OAC buffer containing gentisic acid and incubating the reaction mixture at 90°C for 30 min. The yield and radiochemical purity of the complex was determined by HPLC technique. Parameters, such as, ligand-to-metal ratio, pH of the reaction mixture, incubation time and temperature were varied using tracer quantity of (177)Lu (37 MBq) in order to arrive at the optimized protocol for the preparation of clinical dose. Biological behavior of the radiotracer prepared was studied in C57/BL6 mice bearing melanoma tumors. (177)Lu was produced with a specific activity of 950 ± 50 GBq/mg (25.7 ± 1.4 Ci/mg) and radionuclidic purity of 99.98%. A careful optimization of several parameters showed that (177)Lu-DOTA-E[c(RGDfK)]2 could be prepared with adequately high radiochemical purity using a ligand-to-metal ratio ~2. Based on these studies therapeutic dose of the agent with 7.4 GBq of (177)Lu was formulated in ~63 GBq/μM specific activity with high yield (98.2 ± 0.7%), radiochemical purity and in vitro stability. Biodistribution studies carried out in C57/BL6 mice bearing melanoma tumors revealed specific accumulation of the radiolabeled conjugate in tumor (3.80 ± 0.55% ID/g at 30 min p.i.) with high tumor to blood and tumor to muscle ratios. However, the uptake of the radiotracer in the tumor was found to be reduced to 1.51 ± 0.32 %ID/g at 72 h p.i. The present work successfully demonstrates the formulation of an optimized protocol for the preparation of (177)Lu labeled DOTA-E[c(RGDfK)]2 for PRRT applications using (177)Lu produced by direct neutron activation in a medium flux research reactor. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. New techniques for positron emission tomography in the study of human neurological disorders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1992-07-01

    The general goals of the physics and kinetic modeling projects are to: (1) improve the quantitative information extractable from PET images, and (2) develop, implement and optimize tracer kinetic models for new PET neurotransmitter/receptor ligands aided by computer simulations. Work towards improving PET quantification has included projects evaluating: (1) iterative reconstruction algorithms using supplemental boundary information, (2) automated registration of dynamic PET emission and transmission data using sinogram edge detection, and (3) automated registration of multiple subjects to a common coordinate system, including the use of non-linear warping methods. Simulation routines have been developed providing more accurate representation of datamore » generated from neurotransmitter/receptor studies. Routines consider data generated from complex compartmental models, high or low specific activity administrations, non-specific binding, pre- or post-injection of cold or competing ligands, temporal resolution of the data, and radiolabeled metabolites. Computer simulations and human PET studies have been performed to optimize kinetic models for four new neurotransmitter/receptor ligands, [{sup 11}C]TRB (muscarinic), [{sup 11}C]flumazenil (benzodiazepine), [{sup 18}F]GBR12909, (dopamine), and [{sup 11}C]NMPB (muscarinic).« less

  18. New techniques for positron emission tomography in the study of human neurological disorders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1992-01-01

    The general goals of the physics and kinetic modeling projects are to: (1) improve the quantitative information extractable from PET images, and (2) develop, implement and optimize tracer kinetic models for new PET neurotransmitter/receptor ligands aided by computer simulations. Work towards improving PET quantification has included projects evaluating: (1) iterative reconstruction algorithms using supplemental boundary information, (2) automated registration of dynamic PET emission and transmission data using sinogram edge detection, and (3) automated registration of multiple subjects to a common coordinate system, including the use of non-linear warping methods. Simulation routines have been developed providing more accurate representation of datamore » generated from neurotransmitter/receptor studies. Routines consider data generated from complex compartmental models, high or low specific activity administrations, non-specific binding, pre- or post-injection of cold or competing ligands, temporal resolution of the data, and radiolabeled metabolites. Computer simulations and human PET studies have been performed to optimize kinetic models for four new neurotransmitter/receptor ligands, ({sup 11}C)TRB (muscarinic), ({sup 11}C)flumazenil (benzodiazepine), ({sup 18}F)GBR12909, (dopamine), and ({sup 11}C)NMPB (muscarinic).« less

  19. Development of a Dual Tracer PET Method for Imaging Dopaminergic Neuromodulation

    NASA Astrophysics Data System (ADS)

    Converse, Alexander K.; Dejesus, Onofre T.; Flores, Leo G.; Holden, James E.; Kelley, Ann E.; Moirano, Jeffrey M.; Nickles, Robert J.; Oakes, Terrence R.; Roberts, Andrew D.; Ruth, Thomas J.; Vandehey, Nicholas T.; Davidson, Richard J.

    2006-04-01

    The modulatory neurotransmittor dopamine (DA) is involved in movement and reward behaviors, and malfunctions in the dopamine system are implicated in a variety of prevalent and debilitating pathologies including Parkinson's disease, attention deficit/hyperactivity disorder, schizophrenia, and addiction. Positron emission tomography (PET) has been used to separately measure changes in DA receptor occupancy and blood flow in response to various interventions. Here we describe a dual tracer PET method to simultaneously measure both responses with the aim of comparing DA release in particular areas of the brain and associated alterations in neural activity throughout the brain. Significant correlations between reductions in DA receptor occupancy and blood flow alterations would be potential signs of dopaminergic modulation, i.e. modifications in signal processing due to increased levels of extracellular DA. Methodological development has begun with rats undergoing an amphetamine challenge while being scanned with the blood flow tracer [17F]fluoromethane and the dopamine D2 receptor tracer [18F]desmethoxyfallypride.

  20. A decay of gap junctions associated with ganglion cell differentiation during retinal regeneration of the adult newt.

    PubMed

    Oi, Hanako; Chiba, Chikafumi; Saito, Takehiko

    2003-12-01

    Changes in the gap junctional coupling and maturation of voltage-activated Na(+) currents during regeneration of newt retinas were examined by whole-cell patch-clamping in slice preparations. Progenitor cells in regenerating retinas did not exhibit Na(+) currents but showed prominent electrical and tracer couplings. Cells identified by LY-fills were typically slender. Na(+) currents were detected in premature ganglion cells with round somata in the 'intermediate-II' regenerating retina. No electrical and tracer couplings were observed between these cells. Mature ganglion cells did not exhibit electrical coupling, but showed tracer coupling. On average, the maximum Na(+) current amplitude recorded from premature ganglion cells was roughly 2.5-fold smaller than that of mature ganglion cells. In addition, the activation threshold of the Na(+) current was nearly 11 mV more positive than that of mature cells. We provide morphological and physiological evidence showing that loss of gap junctions between progenitor cells is associated with ganglion cell differentiation during retinal regeneration and that new gap junctions are recreated between mature ganglion cells. Also we provide evidence suggesting that the loss of gap junctions correlates with the appearance of voltage-activated Na(+) currents in ganglion cells.

  1. Bioelectrochemical Magnetic Immunosensing of Trichloropyridinol: A Potential Insecticide Biomarker

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Guodong; Timchalk, Chuck; Lin, Yuehe

    2006-07-01

    A magnetic beads-based bioelectrochemical magnetic immunosensor was developed for the fast and sensitive determination of the trichloropyridinol (TCP) biomarker in environmental samples. After liquid phrase competitive immunoreaction among a limited amount of TCP antibody coated-magnetic beads (Ab-MBs), TCP analyte, and horseradish peroxidase (HRP) labeled TCP (HRP-TCP), a magnet/glassy carbon (MGC) electrode was used to collect a TCP-Abs-MBs and a HRP-TCP-Ab-MBs immunocomplex assembly. The activity of HRP tracers bound to the beads was monitored with highly sensitive square wave voltammetry (SWV) by accumulating an electroactive enzymatic product to the MGC electrode surface under constant potential (0.5 V) during enzymatic reaction inmore » the presence of 3’,3’,5’,5’-tetramethylbenzidine (TMB)-H2O2 substrate solution. The electrochemical characteristics of substrate and product were investigated, and the parameters of the immunoassay were optimized.« less

  2. New techniques for positron emission tomography in the study of human neurological disorders. Progress report, June 1990--June 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhl, D.E.

    1993-06-01

    This progress report describes accomplishments of four programs. The four programs are entitled (1) Faster,simpler processing of positron-computing precursors: New physicochemical approaches, (2) Novel solid phase reagents and methods to improve radiosynthesis and isotope production, (3) Quantitative evaluation of the extraction of information from PET images, and (4) Optimization of tracer kinetic methods for radioligand studies in PET.

  3. Simulation of tissue activity curves of 64Cu-ATSM for sub-target volume delineation in radiotherapy

    NASA Astrophysics Data System (ADS)

    Dalah, E.; Bradley, D.; Nisbet, A.

    2010-02-01

    There is much interest in positron emission tomography (PET) for measurements of regional tracer concentration in hypoxic tumour-bearing tissue, focusing on the need for accurate radiotherapy treatment planning. Generally, relevant data are taken over multiple time frames in the form of tissue activity curves (TACs), thus providing an indication of vasculature structure and geometry. This is a potential key in providing information on cellular perfusion and limited diffusion. A number of theoretical studies have attempted to describe tracer uptake in tissue cells in an effort to understand such complicated behaviour of cellular uptake and the mechanism of washout. More recently, a novel computerized reaction diffusion equation method was developed by Kelly and Brady (2006 A model to simulate tumour oxygenation and dynamic [18F]-FMISO PET data Phys. Med. Biol. 51 5859-73), where they managed to simulate the realistic dynamic TACs of 18F-FMISO. The model was developed over a multi-step process. Here we present a refinement to the work of Kelly and Brady, such that the model allows simulation of a realistic tissue activity curve (TAC) of any hypoxia selective PET tracer, in a single step process. In this work we show particular interest in simulating the TAC of perhaps the most promising hypoxia selective tracer, 64Cu-ATSM. In addition, we demonstrate its potential role in tumour sub-volume delineation for radiotherapy treatment planning. Simulation results have demonstrated the significant high contrast of imaging using ATSM, with a tumour to blood ratio ranging from 2.24 to 4.1.

  4. Application of stable‐isotope labelling techniques for the detection of active diazotrophs

    PubMed Central

    Angel, Roey; Panhölzl, Christopher; Gabriel, Raphael; Herbold, Craig; Wanek, Wolfgang; Richter, Andreas; Eichorst, Stephanie A.

    2017-01-01

    Summary Investigating active participants in the fixation of dinitrogen gas is vital as N is often a limiting factor for primary production. Biological nitrogen fixation is performed by a diverse guild of bacteria and archaea (diazotrophs), which can be free‐living or symbionts. Free‐living diazotrophs are widely distributed in the environment, yet our knowledge about their identity and ecophysiology is still limited. A major challenge in investigating this guild is inferring activity from genetic data as this process is highly regulated. To address this challenge, we evaluated and improved several 15N‐based methods for detecting N2 fixation activity (with a focus on soil samples) and studying active diazotrophs. We compared the acetylene reduction assay and the 15N2 tracer method and demonstrated that the latter is more sensitive in samples with low activity. Additionally, tracing 15N into microbial RNA provides much higher sensitivity compared to bulk soil analysis. Active soil diazotrophs were identified with a 15N‐RNA‐SIP approach optimized for environmental samples and benchmarked to 15N‐DNA‐SIP. Lastly, we investigated the feasibility of using SIP‐Raman microspectroscopy for detecting 15N‐labelled cells. Taken together, these tools allow identifying and investigating active free‐living diazotrophs in a highly sensitive manner in diverse environments, from bulk to the single‐cell level. PMID:29027346

  5. The solar cycle variation of the rates of CMEs and related activity

    NASA Technical Reports Server (NTRS)

    Webb, David F.

    1991-01-01

    Coronal mass ejections (CMEs) are an important aspect of the physics of the corona and heliosphere. This paper presents results of a study of occurrence frequencies of CMEs and related activity tracers over more than a complete solar activity cycle. To properly estimate occurrence rates, observed CME rates must be corrected for instrument duty cycles, detection efficiencies away from the skyplane, mass detection thresholds, and geometrical considerations. These corrections are evaluated using CME data from 1976-1989 obtained with the Skylab, SMM and SOLWIND coronagraphs and the Helios-2 photometers. The major results are: (1) the occurrence rate of CMEs tends to track the activity cycle in both amplitude and phase; (2) the corrected rates from different instruments are reasonably consistent; and (3) over the long term, no one class of solar activity tracer is better correlated with CME rate than any other (with the possible exception of type II bursts).

  6. Wear Measurement of Highly Cross-linked UHMWPE using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus A.; Laurent, Michael P.; Dwivedi, Yasha

    2013-01-01

    The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenousmore » distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  7. The Thrombin Receptor Antagonist for Clinical Event Reduction in Acute Coronary Syndrome (TRA*CER) trial: study design and rationale.

    PubMed

    2009-09-01

    The protease-activated receptor 1 (PAR-1), the main platelet receptor for thrombin, represents a novel target for treatment of arterial thrombosis, and SCH 530348 is an orally active, selective, competitive PAR-1 antagonist. We designed TRA*CER to evaluate the efficacy and safety of SCH 530348 compared with placebo in addition to standard of care in patients with non-ST-segment elevation (NSTE) acute coronary syndromes (ACS) and high-risk features. TRA*CER is a prospective, randomized, double-blind, multicenter, phase III trial with an original estimated sample size of 10,000 subjects. Our primary objective is to demonstrate that SCH 530348 in addition to standard of care will reduce the incidence of the composite of cardiovascular death, myocardial infarction (MI), stroke, recurrent ischemia with rehospitalization, and urgent coronary revascularization compared with standard of care alone. Our key secondary objective is to determine whether SCH 530348 will reduce the composite of cardiovascular death, MI, or stroke compared with standard of care alone. Secondary objectives related to safety are the composite of moderate and severe GUSTO bleeding and clinically significant TIMI bleeding. The trial will continue until a predetermined minimum number of centrally adjudicated primary and key secondary end point events have occurred and all subjects have participated in the study for at least 1 year. The TRA*CER trial is part of the large phase III SCH 530348 development program that includes a concomitant evaluation in secondary prevention. TRA*CER will define efficacy and safety of the novel platelet PAR-1 inhibitor SCH 530348 in the treatment of high-risk patients with NSTE ACS in the setting of current treatment strategies.

  8. An Ultralow-Dose 1-Day Protocol With Activities Lower Than 20 MBq for the Detection of Sentinel Lymph Nodes in Breast Cancer-Experiences After 150 Cases.

    PubMed

    Kolberg, Hans-Christian; Afsah, Shabnam; Kuehn, Thorsten; Winzer, Ute; Akpolat-Basci, Leyla; Stephanou, Miltiades; Wetzig, Sarah; Hoffmann, Oliver; Liedtke, Cornelia

    2017-01-01

    Common protocols for the detection of sentinel lymph nodes in early breast cancer often include the injection of the tracer 1 day before surgery. In order to detect enough activity on the day of surgery, the applied activity in many protocols is as high as several hundred MBq. So far, very few protocols with an activity below 20 MBq have been reported. We developed an ultralow-dose 1-day protocol with a mean activity lower than 20 MBq in order to reduce radiation exposure for patients and staff. Here, we are presenting our experiences in 150 consecutive cases. A total of 150 patients with clinically and sonographically negative axilla and no multicentricity underwent a sentinel lymph node biopsy using an ultralow-dose protocol performed on the day of surgery. No patient received systemic therapy prior to sentinel node biopsy. After peritumoral injection of the tracer Technetium-99m, a lymphoscintigraphy was performed in all cases. Seven minutes before the first cut, we injected 5 mL of blue dye in the region of the areola. In 148 (98.7%) of 150 patients, at least 1 sentinel lymph node could be identified by lymphoscintigraphy; the detection rate during surgery with combined tracers Technetium-99m and blue dye was 100%. The mean applied activity was 17.8 MBq (9-20). A mean number of 1.3 (0-5) sentinel lymph nodes were identified by lymphoscintigraphy and a mean number of 1.8 (1-5) sentinel lymph nodes were removed during sentinel lymph node biopsy. Ultralow-dose 1-day protocols with an activity lower than 20 MBq are a safe alternative to 1-day or 2-day protocols with significantly higher radiation doses in primary surgery for early breast cancer. Using Technetium-99m and blue dye in a dual tracer approach, detection rates of 100% are possible in clinical routine in order to reduce radiation exposure for patients and staff.

  9. Detection of Active Topology Probing Deception

    DTIC Science & Technology

    2015-09-01

    patterns in the gag traceroutes and fake topologies from the DeTracer for which we may use to improve our filtering process. In all, the findings will aid...in the /24 subnet. We find intriguing patterns in the gag traceroutes and fake topologies from the DeTracer for which we may use to improve our...Forwarding xiv Acknowledgments I would like to thank Dr. Robert Beverly for his patience during the research and thesis writing process. His deep knowledge on

  10. Validation of methodology for determination of the mercury methylation potential in sediments using radiotracers.

    PubMed

    Zizek, Suzana; Ribeiro Guevara, Sergio; Horvat, Milena

    2008-04-01

    Experiments to determine the mercury methylation potential were performed on sediments from two locations on the river Idrijca (Slovenia), differing in ambient mercury concentrations. The tracer used was the radioactive isotope (197)Hg. The benefit of using this tracer is its high specific activity, which enables spikes as low as 0.02 ng Hg(2+) g(-1) of sample to be used. It was therefore possible to compare the efficiency of the methylation potential experiments over a range of spike concentrations from picogram to microgram levels. The first part of the work aimed to validate the experimental blanks and the second part consisted of several series of incubation experiments on two different river sediments using a range of tracer additions. The results showed high variability in the obtained methylation potentials. Increasing Hg(2+) additions gave a decrease in the percentage of the tracer methylated during incubation; in absolute terms, the spikes that spanned four orders of magnitude (0.019-190 pg g(-1) of sediment slurry) resulted in MeHg formation between 0.01 and 0.1 ng MeHg g(-1) in Podroteja and Kozarska Grapa. Higher spikes resulted in slightly elevated MeHg production (up to a maximum of 0.27 ng g(-1)). The values of methylation potential were similar in both sediments. The results imply that the experimental determination of mercury methylation potential strongly depends on the experimental setup itself and the amount of tracer added to the system under study. It is therefore recommended to use different concentrations of tracer and perform the experiments in several replicates. The amount of mercury available for methylation in nature is usually very small. Therefore, adding very low amounts of tracer in the methylation potential studies probably gives results that have a higher environmental relevance. It is also suggested to express the results obtained in absolute amounts of MeHg produced and not just as the percentage of the added tracer.

  11. Using A New Model for Main Sequence Turnoff Absolute Magnitudes to Measure Stellar Streams in the Milky Way Halo

    NASA Astrophysics Data System (ADS)

    Weiss, Jake; Newberg, Heidi Jo; Arsenault, Matthew; Bechtel, Torrin; Desell, Travis; Newby, Matthew; Thompson, Jeffery M.

    2016-01-01

    Statistical photometric parallax is a method for using the distribution of absolute magnitudes of stellar tracers to statistically recover the underlying density distribution of these tracers. In previous work, statistical photometric parallax was used to trace the Sagittarius Dwarf tidal stream, the so-called bifurcated piece of the Sagittaritus stream, and the Virgo Overdensity through the Milky Way. We use an improved knowledge of this distribution in a new algorithm that accounts for the changes in the stellar population of color-selected stars near the photometric limit of the Sloan Digital Sky Survey (SDSS). Although we select bluer main sequence turnoff stars (MSTO) as tracers, large color errors near the survey limit cause many stars to be scattered out of our selection box and many fainter, redder stars to be scattered into our selection box. We show that we are able to recover parameters for analogues of these streams in simulated data using a maximum likelihood optimization on MilkyWay@home. We also present the preliminary results of fitting the density distribution of major Milky Way tidal streams in SDSS data. This research is supported by generous gifts from the Marvin Clan, Babette Josephs, Manit Limlamai, and the MilkyWay@home volunteers.

  12. Substance P and acetylcholine are co-localized in the pathway mediating mucociliary activity in Rana pipiens

    PubMed Central

    Hernández, C. J.; Ortíz, T.; Foster, C. Rosa K.; Tyagi, M; Lugo, N.; Albrecht, R.; Chinapen, S.

    2007-01-01

    Mucociliary activity is an important clearance mechanism in the respiratory system of air breathing vertebrates. Substance P (SP) and acetylcholine play a key role in the stimulation of the mucociliary transport in the frog palate. In this study, retrograde neuronal tracing was combined with immunocytochemistry for SP and choline acetyl transferase (ChAT) in the trigeminal ganglion and for neurokinin-1 receptor (NK1R) in the palate of Rana pipiens. The cells of origin of the palatine nerve were identified in the trigeminal ganglion using the retrograde tracer Fluorogold (FG). Optimal labeling of FG cells in the trigeminal ganglion was obtained at 96 h of exposure. Immunoflorescent shows that SP and acetylcholine are co-localized in 92% of the cells labeled with FG in the trigeminal ganglion. NK1 receptors were found in the membrane of epithelial and goblet cells of the palate. Ultrastructural study of the palate showed axonal-like endings with vesicles in connection with epithelial and goblet cells. These results further support the concerted action of both neurotransmitters in the regulation of mucociliary activity in the frog palate. PMID:17276713

  13. Optimization of automated large-scale production of [(18)F]fluoroethylcholine for PET prostate cancer imaging.

    PubMed

    Pascali, Giancarlo; D'Antonio, Luca; Bovone, Paola; Gerundini, Paolo; August, Thorsten

    2009-07-01

    PET tumor imaging is gaining importance in current clinical practice. FDG-PET is the most utilized approach but suffers from inflammation influences and is not utilizable in prostate cancer detection. Recently, (11)C-choline analogues have been employed successfully in this field of imaging, leading to a growing interest in the utilization of (18)F-labeled analogues: [(18)F]fluoroethylcholine (FEC) has been demonstrated to be promising, especially in prostate cancer imaging. In this work we report an automatic radiosynthesis of this tracer with high yields, short synthesis time and ease of performance, potentially utilizable in routine production sites. We used a Modular Lab system to automatically perform the two-step/one-pot synthesis. In the first step, we labeled ethyleneglycolditosylate obtaining [(18)F]fluoroethyltosylate; in the second step, we performed the coupling of the latter intermediate with neat dimethylethanolamine. The final mixture was purified by means of solid phase extraction; in particular, the product was trapped into a cation-exchange resin and eluted with isotonic saline. The optimized procedure resulted in a non decay corrected yield of 36% and produced a range of 30-45 GBq of product already in injectable form. The product was analyzed for quality control and resulted as pure and sterile; in addition, residual solvents were under the required threshold. In this work, we present an automatic FEC radiosynthesis that has been optimized for routine production. This findings should foster the interest for a wider utilization of this radiomolecule for imaging of prostate cancer with PET, a field for which no gold-standard tracer has yet been validated.

  14. Do Chondral Lesions of the Knee Correlate with Bone Tracer Uptake by Using SPECT/CT?

    PubMed

    Dordevic, Milos; Hirschmann, Michael T; Rechsteiner, Jan; Falkowski, Anna; Testa, Enrique; Hirschmann, Anna

    2016-01-01

    To evaluate the correlation of bone tracer uptake as determined with single photon emission computed tomography (SPECT)/computed tomography (CT) and the size and severity of chondral lesions detected with magnetic resonance (MR) imaging of the knee. MR imaging and SPECT/CT images of 63 knee joints in 63 patients (mean age ± standard deviation, 49.2 years ± 12.7) with chondral or osteochondral lesions were prospectively collected and retrospectively analyzed after approval by the ethics committee. Chondral lesions were graded on MR images by using a modified Noyes grading scale (grade 0, intact; grade 1, fibrillations; grade 2, <50% defect; grade 3, >50% defect; and grade 4, grade three plus subchondral changes) and measured in two dimensions. Technetium 99m hydroxymethane diphosphonate SPECT/CT bone tracer uptake was volumetrically quantified by using validated software. Maximum values of each subchondral area (patellofemoral or medial and lateral femorotibial) were quantified, and a ratio was calculated in relation to a reference region in the femoral shaft, which represented the bone tracer uptake background activity. Grades and sizes of chondral lesions and bone tracer uptake were correlated by using an independent t test and analysis of variance (P < .05). Bone tracer uptake was low (mean relative uptake, 1.64 ± 0.95) in knees without any present chondral lesion. In knees with grade 3 and 4 chondral lesions, the relative ratio was significantly higher (3.62 ± 2.18, P = .002) than in knees with grade 1 and 2 lesions (2.95 ± 2.07). The larger the diameter of the chondral lesion, the higher the bone tracer uptake. Higher grades of chondral lesions (grades 3 and 4) larger than 4 cm(2) (4.96 ± 2.43) showed a significantly higher bone tracer uptake than smaller lesions (<1 cm(2), 2.72 ± 1.43 [P = .011]; and 1-4 cm(2), 3.28 ± 2.15 [P = .004]). SPECT/CT findings significantly correlate with the degree and size of chondral lesions on MR images. Grade 3 and 4 chondral lesions of the knee, as well as larger lesions, correlate with a high bone tracer uptake. © RSNA, 2015.

  15. Development of an advanced support system for site investigations

    NASA Astrophysics Data System (ADS)

    Mizuno, T.; Hama, K.; Iwatsuki, T.; Semba, T.

    2009-12-01

    JAEA has the responsibility for R&D to enhance reliability of High Level Waste (HLW) disposal technology and to develop safety assessment methodology with associated databases; these should support both the implementer (NUMO) and the relevant regulatory organizations. With this responsibility, JAEA has initiated development of advanced technology in the field of Knowledge Engineering. Known as the Information Synthesis and Interpretation System (ISIS), it incorporates knowledge currently being obtained in the Underground Research Laboratory (URL) projects in Expert System (ES) modules for the Japanese HLW disposal program. This knowledge includes fundamental understanding of relevant geological environments, technical know-how for the application of complex investigation techniques, experience gained in earlier site work, etc. However, much knowledge is not undocumented because the knowledge is treated as tacit knowledge and, without focused action soon, may be permanently lost. Therefore, a new approach is necessary to transfer the knowledge obtained in these URL projects to support the site characterization and subsequent safety assessment of potential repository sites by NUMO and the formulation of guidelines by regulatory organizations. In this paper, we introduce the ES for selecting tracers for borehole drilling. ES is the system built by applying electronic information technology to support the planning, conducting investigations and assessing of investigation results. Tracers are generally used for borehole drilling to monitor and quantitatively assess the degree of contamination of groundwater by drilling fluid. JAEA uses fluorescent dye as tracer in drilling fluid. When a fluorescent dye is used for drilling, suitable type and concentration must be selected. The technical points to be considered are; 1) linearity of fluorescent spectrum intensity with variations in concentration, 2) pH dependence of fluorescent spectrum intensity, 3) stability of fluorescent dye, 4) sorption/adsorption properties for rock being investigated, 5) detection limit of analyzer, 6) comparison of the fluorescent spectrum with dissolved organics and tracers used in other boreholes. In addition, costs and environmental impact are important factors to be considered. Thus, significant knowledge is needed in selecting the tracer for actual investigations. Fortunately, the ES for tracer selection already contains much knowledge needed. For example, the chemical data set for a suite of fluorescence dyes is in the ES, along with guidelines for their use. Therefore, this ES can support the use of fluorescent dye as tracer in actual investigations, even if the investigating scientists have little or no experience with it. In conclusion, the ES modules are and will be built as a support system for future researchers to perform optimized site investigations in a user-friendly manner. In this paper, we introduce the ES for selection of borehole drilling fluid tracer. Eventually, ES covering the full range of site investigation methods will be developed.

  16. Analysis of Conservative Tracer Tests in the Bullfrog, Tram, and Prow Pass Tuffs, 1996 to 1998, Yucca Mountain, Nye County, Nevada

    USGS Publications Warehouse

    Umari, Amjad; Fahy, Michael F.; Earle, John D.; Tucci, Patrick

    2008-01-01

    To evaluate the potential for transport of radionuclides in ground water from the proposed high-level nuclear-waste repository at Yucca Mountain, Nevada, conservative (nonsorbing) tracer tests were conducted among three boreholes, known as the C-hole Complex, and values for transport (or flow) porosity, storage (or matrix) porosity, longitudinal dispersivity, and the extent of matrix diffusion were obtained. The C-holes are completed in a sequence of Miocene tuffaceous rock, consisting of nonwelded to densely welded ash-flow tuff with intervals of ash-fall tuff and volcaniclastic rocks, covered by Quaternary alluvium. The lower part of the tuffaceous-rock sequence includes the Prow Pass, Bullfrog, and Tram Tuffs of the Crater Flat Group. The rocks are pervaded by tectonic and cooling fractures. Paleozoic limestone and dolomite underlie the tuffaceous rocks. Four radially convergent and one partially recirculating conservative (nonsorbing) tracer tests were conducted at the C-hole Complex from 1996 to 1998 to establish values for flow porosity, storage porosity, longitudinal dispersivity, and extent of matrix diffusion in the Bullfrog and Tram Tuffs and the Prow Pass Tuff. Tracer tests included (1) injection of iodide into the combined Bullfrog-Tram interval; (2) injection of 2,6 difluorobenzoic acid into the Lower Bullfrog interval; (3) injection of 3-carbamoyl-2-pyridone into the Lower Bullfrog interval; and (4) injection of iodide and 2,4,5 trifluorobenzoic acid, followed by 2,3,4,5 tetrafluorobenzoic acid, into the Prow Pass Tuff. All tracer tests were analyzed by the Moench single- and dual-porosity analytical solutions to the advection-dispersion equation or by superposition of these solutions. Nonlinear regression techniques were used to corroborate tracer solution results, to obtain optimal parameter values from the solutions, and to quantify parameter uncertainty resulting from analyzing two of the three radially convergent conservative tracer tests conducted in the Bullfrog and Tram intervals. Longitudinal dispersivity values in the Bullfrog and Tram Tuffs ranged from 1.83 to 2.6 meters, flow-porosity values from 0.072 to 0.099, and matrix-porosity values from 0.088 to 0.19. The flow-porosity values indicate that the pathways between boreholes UE-25 c#2 and UE-25 c#3 in the Bullfrog and Tram intervals are not connected well. Tracer testing in the Prow Pass interval indicates different transport characteristics than those obtained in the Bullfrog and Tram intervals. In the Prow Pass Tuff, longitudinal dispersivity was 0.27 meter, flow porosity was 4.5 ? 10?4, and matrix porosity was 0.01. This indicates that the flow network in the Prow Pass is dominated by interconnected fractures, whereas in the Bullfrog and Tram, the flow network is dominated by discontinuous fractures with connecting segments of matrix.

  17. Education: DNA replication using microscale natural convection.

    PubMed

    Priye, Aashish; Hassan, Yassin A; Ugaz, Victor M

    2012-12-07

    There is a need for innovative educational experiences that unify and reinforce fundamental principles at the interface between the physical, chemical, and life sciences. These experiences empower and excite students by helping them recognize how interdisciplinary knowledge can be applied to develop new products and technologies that benefit society. Microfluidics offers an incredibly versatile tool to address this need. Here we describe our efforts to create innovative hands-on activities that introduce chemical engineering students to molecular biology by challenging them to harness microscale natural convection phenomena to perform DNA replication via the polymerase chain reaction (PCR). Experimentally, we have constructed convective PCR stations incorporating a simple design for loading and mounting cylindrical microfluidic reactors between independently controlled thermal plates. A portable motion analysis microscope enables flow patterns inside the convective reactors to be directly visualized using fluorescent bead tracers. We have also developed a hands-on computational fluid dynamics (CFD) exercise based on modeling microscale thermal convection to identify optimal geometries for DNA replication. A cognitive assessment reveals that these activities strongly impact student learning in a positive way.

  18. Identification of a Second Site of Pyrrolizidine Alkaloid Biosynthesis in Comfrey to Boost Plant Defense in Floral Stage1,2[OPEN

    PubMed Central

    Stegemann, Thomas; Sievert, Christian

    2017-01-01

    Pyrrolizidine alkaloids (PAs) are toxic secondary metabolites that are found in several distantly related families of the angiosperms. The first specific step in PA biosynthesis is catalyzed by homospermidine synthase (HSS), which has been recruited several times independently by duplication of the gene encoding deoxyhypusine synthase, an enzyme involved in the posttranslational activation of the eukaryotic initiation factor 5A. HSS shows highly diverse spatiotemporal gene expression in various PA-producing species. In comfrey (Symphytum officinale; Boraginaceae), PAs are reported to be synthesized in the roots, with HSS being localized in cells of the root endodermis. Here, we show that comfrey plants activate a second site of HSS expression when inflorescences start to develop. HSS has been localized in the bundle sheath cells of specific leaves. Tracer feeding experiments have confirmed that these young leaves express not only HSS but the whole PA biosynthetic route. This second site of PA biosynthesis results in drastically increased PA levels within the inflorescences. The boost of PA biosynthesis is proposed to guarantee optimal protection especially of the reproductive structures. PMID:28275146

  19. Attempting to link hydro-morphology, transient storage and metabolism in streams: Insights from reactive tracer experiments

    NASA Astrophysics Data System (ADS)

    Kurz, Marie J.; Schmidt, Christian; Blaen, Phillip; Knapp, Julia L. A.; Drummond, Jennifer D.; Martí, Eugenia; Zarnetske, Jay P.; Ward, Adam S.; Krause, Stefan

    2016-04-01

    In-stream transient storage zones, including the hyporheic zone and vegetation beds, can be hotspots of biogeochemical processing in streams, enhancing ecosystem functions such as metabolism and nutrient uptake. The spatio-temporal dynamics and reactivity of these storage zones are influenced by multiple factors, including channel geomorphology, substrate composition and hydrology, and by anthropogenic modifications to flow regimes and nutrient loads. Tracer injections are a commonly employed method to evaluate solute transport and transient storage in streams; however, reactive tracers are needed to differentiate between metabolically active and inactive transient storage zones. The reactive stream tracer resazurin (Raz), a weakly fluorescent dye which irreversibly transforms to resorufin (Rru) under mildly reducing conditions, provides a proxy for aerobic respiration and an estimate of the metabolic activity associated with transient storage zones. Across a range of lotic ecosystems, we try to assess the influence of stream channel hydro-morphology, morphologic heterogeneity, and substrate type on reach (103 m) and sub-reach (102 m) scale transient storage, respiration, and nutrient uptake. To do so, we coupled injections of Raz and conservative tracers (uranine and/or salt) at each study site. The study sites included: vegetated mesocosms controlled for water depth; vegetated and un-vegetated sediment-filled mesocosms fed by waste-water effluent; a contrasting sand- vs. gravel-bedded lowland stream (Q = 0.08 m3/s); and a series of upland streams with varying size (Q = 0.1 - 1.5 m3/s) and prevalence of morphologic features. Continuous time-series of tracer concentrations were recorded using in-situ fluorometers and EC loggers. At the stream sites, time-series were recorded at multiple downstream locations in order to resolve sub-reach dynamics. Analyses yielded highly variable transport metrics and Raz-Rru transformation between study sites and between sub-reaches within stream sites. Higher Raz-Rru transformation rates were typically observed in smaller streams, in sub-reaches with higher prevalence of morphologic features known to promote hyporheic exchange, and in mesocosms with higher water depth, vegetation density and retention time. However, relationships between transformation rates and common metrics of transient storage were not consistent among study cases, indicating the existence of yet unrealized complexities in the relationships between water and solute transport and metabolism. Further insights were also gained related to the utility of Raz and improved tracer test practices.

  20. Tracer methodology: an appropriate tool for assessing compliance with accreditation standards?

    PubMed

    Bouchard, Chantal; Jean, Olivier

    2017-10-01

    Tracer methodology has been used by Accreditation Canada since 2008 to collect evidence on the quality and safety of care and services, and to assess compliance with accreditation standards. Given the importance of this methodology in the accreditation program, the objective of this study is to assess the quality of the methodology and identify its strengths and weaknesses. A mixed quantitative and qualitative approach was adopted to evaluate consistency, appropriateness, effectiveness and stakeholder synergy in applying the methodology. An online questionnaire was sent to 468 Accreditation Canada surveyors. According to surveyors' perceptions, tracer methodology is an effective tool for collecting useful, credible and reliable information to assess compliance with Qmentum program standards and priority processes. The results show good coherence between methodology components (appropriateness of the priority processes evaluated, activities to evaluate a tracer, etc.). The main weaknesses are the time constraints faced by surveyors and management's lack of cooperation during the evaluation of tracers. The inadequate amount of time allowed for the methodology to be applied properly raises questions about the quality of the information obtained. This study paves the way for a future, more in-depth exploration of the identified weaknesses to help the accreditation organization make more targeted improvements to the methodology. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantone, M.C.

    The interest in biokinetic studies is driven by problems related to the physiopathology of oligoelements, chemical elemental pollution and radioactive release in case of nuclear accidents. The application of stable isotopes as tracers in studies of trace elements in the area of nutritional and food science is particularly attractive and specifically if considering the investigations on the most radiosensitive age groups of the population and the repeated studies on healthy people for the assessment of the bioavailability of different compounds. A tracer method based on stable isotope administration, which combines the simultaneous use of two tracers and proton activation analysismore » is presented. A study aimed to obtain molybdenum biokinetic data in humans was performed. One tracer ({sup 96}Mo) was orally administered and another ({sup 95}Mo) was intravenously injected to two fasting volunteer subjects. Venous blood samples were withdrawn at different postinjection times. The concentration in plasma for both the isotopes was determined by measuring the intensities of the gamma-lines from the technetium radioisotopes produced via (p,n) reactions. In the adopted experimental conditions a minimum detectable concentration of 2 ng isotope/ml plasma was attained. The parameters describing molybdenum kinetics were obtained for the two individuals. Moreover, the investigation was repeated with different tracer amounts for one of the two subjects, in both fasting and non-fasting condition.« less

  2. Adoptive Immunotherapy for Epithelial Ovarian Cancer Using T-cells Simultaneously Targeted to Tumor and Tumor-Associated Macrophages

    DTIC Science & Technology

    2013-12-01

    SCID Beige mice. The clinically useful PET tracer 18fluorodeoxyglucose ( FDG ) was used for this study since FDG is preferentially taken up by tumors with...increased glycolytic activity. However, Figure 9 demonstrates that SKOV-luc tumors are not FDG avid, precluding the further development of this...cells   exhibited   a   selective   increase   in   tracer  uptake  in  the  outer  rim  surrounding  the  tumor.  (B

  3. Small-Animal Imaging Using Diffuse Fluorescence Tomography.

    PubMed

    Davis, Scott C; Tichauer, Kenneth M

    2016-01-01

    Diffuse fluorescence tomography (DFT) has been developed to image the spatial distribution of fluorescence-tagged tracers in living tissue. This capability facilitates the recovery of any number of functional parameters, including enzymatic activity, receptor density, blood flow, and gene expression. However, deploying DFT effectively is complex and often requires years of know-how, especially for newer mutlimodal systems that combine DFT with conventional imaging systems. In this chapter, we step through the process of using MRI-DFT imaging of a receptor-targeted tracer in small animals.

  4. Linking Metabolic Activity, Microbial Identity, and Microscale Spatial Arrangements in Chemosynthetic Seafloor Habitats

    NASA Astrophysics Data System (ADS)

    Marlow, J.; Hatzenpichler, R.; Girguis, P.

    2018-05-01

    With an innovative combination of metabolic tracers, fluorescent probes, and microscopy, we present a novel way to pinpoint the geobiological drivers of metabolic activity at silicate and carbonate-based chemosynthetic seafloor habitats.

  5. Reactive Tracer Techniques to Quantitatively Monitor Carbon Dioxide Storage in Geologic Formations

    NASA Astrophysics Data System (ADS)

    Matter, J. M.; Carson, C.; Stute, M.; Broecker, W. S.

    2012-12-01

    Injection of CO2 into geologic storage reservoirs induces fluid-rock reactions that may lead to the mineralization of the injected CO2. The long-term safety of geologic CO2 storage is, therefore, determined by in situ CO2-fluid-rock reactions. Currently existing monitoring and verification techniques for CO2 storage are insufficient to characterize the solubility and reactivity of the injected CO2, and to establish a mass balance of the stored CO2. Dissolved and chemically transformed CO2 thus avoid detection. We developed and are testing a new reactive tracer technique for quantitative monitoring and detection of dissolved and chemically transformed CO2 in geologic storage reservoirs. The technique involves tagging the injected carbon with radiocarbon (14C). Carbon-14 is a naturally occurring radioisotope produced by cosmic radiation and made artificially by 14N neutron capture. The ambient concentration is very low with a 14C/12C ratio of 10-12. The concentration of 14C in deep geologic formations and fossil fuels is at least two orders of magnitude lower. This makes 14C an ideal quantitative tracer for tagging underground injections of anthropogenic CO2. We are testing the feasibility of this tracer technique at the CarbFix pilot injection site in Iceland, where approximately 2,000 tons of CO2 dissolved in water are currently injected into a deep basalt aquifer. The injected CO2 is tagged with 14C by dynamically adding calibrated amounts of H14CO3 solution to the injection stream. The target concentration is 12 Bq/kg of injected water, which results in a 14C activity that is 5 times enriched compared to the 1850 background. In addition to 14C as a reactive tracer, trifluormethylsulphur pentafluoride (SF5CF3) and sulfurhexafluoride (SF6) are used as conservative tracers to monitor the transport of the injected CO2 in the subsurface. Fluid samples are collected for tracer analysis from the injection and monitoring wells on a regular basis. Results show a fast reaction of the injected CO2 with the ambient reservoir fluid and rocks. Mixing and in situ CO2-water-rock reactions are detected by changes in the different tracer ratios. The feasibility of 14C as a reactive tracer for geologic CO2 storage also depends on the analytical technique used to measure 14C activities. Currently, 14C is analyzed using Accelerator Mass Spectrometery (AMS), which is expensive and requires centralized facilities. To enable real time online monitoring and verification, we are developing an alternative detection method for radiocarbon. The IntraCavity OptoGalvanic Spectroscopy (ICOGS) system is using a CO2 laser to detect carbon isotope ratios at environmental levels. Results from our prototype of this bench-top technology demonstrate that an ICOGS system can be used in a continuous mode with analysis times of the order of minutes, and can deliver data of similar quality as AMS.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Findlay, Rick

    The Gnome-Coach, New Mexico, Site was the location of a 3-kiloton-yield underground nuclear test in 1961 and a groundwater tracer test in 1963. The U.S. Geological Survey conducted the groundwater tracer test using four dissolved radionuclides--tritium, iodine-131, strontium-90, and cesium-137--as tracers. Site reclamation and remediation began after the underground testing, and was conducted in several phases at the site. The New Mexico Environment Department (NMED) issued a Conditional Certificate of Completion in September 2014, which documents that surface remediation activities have been successfully completed in accordance with the Voluntary Remediation Program. Subsurface activities have included annual sampling and monitoring ofmore » wells at and near the site since 1972. These annual monitoring activities were enhanced in 2008 to include monitoring hydraulic head and collecting samples from the onsite wells USGS-4, USGS-8, and LRL-7 using the low-flow sampling method. In 2010, the annual monitoring was focused to the monitoring wells within the site boundary. A site inspection and annual sampling were conducted on January 27-28, 2015. A second site visit was conducted on April 21, 2015, to install warning/notification signs to fulfill a requirement of the Conditional Certificate of Completion that was issued by the NMED for the surface.« less

  7. 18F-Alfatide II and 18F-FDG Dual Tracer Dynamic PET for Parametric, Early Prediction of Tumor Response to Therapy

    PubMed Central

    Guo, Jinxia; Guo, Ning; Lang, Lixin; Kiesewetter, Dale O.; Xie, Qingguo; Li, Quanzheng; Eden, Henry S.; Niu, Gang; Chen, Xiaoyuan

    2014-01-01

    A single dynamic PET acquisition using multiple tracers administered closely in time could provide valuable complementary information about a tumor’s status under quasi-constant conditions. This study aims to investigate the utility of dual-tracer dynamic PET imaging with 18F-Alfatide II (18F-AlF-NOTA-E[PEG4-c(RGDfk)]2) and 18F-FDG for parametric monitoring of tumor responses to therapy. Methods We administered doxorubicin to one group of athymic nude mice with U87MG tumors and Abraxane to another group of mice with MDA-MB-435 tumors. To monitor therapeutic responses, we performed dual-tracer dynamic imaging, in sessions that lasted 90 min, starting by injecting the mice via tail vein catheters with 18F-Alfatide II, followed 40 minutes later by 18F-FDG. To achieve signal separation of the two tracers, we fit a three-compartment reversible model to the time activity curve (TAC) of 18F-Alfatide II for the 40 min prior to 18F-FDG injection, and then extrapolated to 90 min. The 18F-FDG tumor TAC was isolated from the 90 min dual tracer tumor TAC by subtracting the fitted 18F-Alfatide II tumor TAC. With separated tumor TACs, the 18F-Alfatide II binding potential (Bp=k3/k4) and volume of distribution (VD), and 18F-FDG influx rate ((K1×k3)/(k2 + k3)) based on the Patlak method were calculated to validate the signal recovery in a comparison with 60-min single tracer imaging and to monitor therapeutic response. Results The transport and binding rate parameters K1-k3 of 18F-Alfatide II, calculated from the first 40 min of dual tracer dynamic scan, as well as Bp and VD, correlated well with the parameters from the 60 min single tracer scan (R2 > 0.95). Compared with the results of single tracer PET imaging, FDG tumor uptake and influx were recovered well from dual tracer imaging. Upon doxorubicin treatment, while no significant changes in static tracer uptake values of 18F-Alfatide II or 18F-FDG were observed, both 18F-Alfatide II Bp and 18F-FDG influx from kinetic analysis in tumors showed significant decreases. For Abraxane therapy of MDA-MB-435 tumors, significant decrease was only observed with 18F-Alfatide II Bp value from kinetic analysis but not 18F-FDG influx. Conclusion The parameters fitted with compartmental modeling from the dual tracer dynamic imaging are consistent with those from single tracer imaging, substantiating the feasibility of this methodology. Even though no significant differences in tumor size were found until 5 days after doxorubicin treatment started, at day 3 there were already substantial differences in 18F-Alfatide II Bp and 18F-FDG influx rate. Dual tracer imaging can measure 18F-Alfatide II Bp value and 18F-FDG influx simultaneously to evaluate tumor angiogenesis and metabolism. Such changes are known to precede anatomical changes, and thus parametric imaging may offer the promise of early prediction of therapy response. PMID:24232871

  8. A Multiple-Tracer Approach for Identifying Sewage Sources to an Urban Stream System

    USGS Publications Warehouse

    Hyer, Kenneth Edward

    2007-01-01

    The presence of human-derived fecal coliform bacteria (sewage) in streams and rivers is recognized as a human health hazard. The source of these human-derived bacteria, however, is often difficult to identify and eliminate, because sewage can be delivered to streams through a variety of mechanisms, such as leaking sanitary sewers or private lateral lines, cross-connected pipes, straight pipes, sewer-line overflows, illicit dumping of septic waste, and vagrancy. A multiple-tracer study was conducted to identify site-specific sources of sewage in Accotink Creek, an urban stream in Fairfax County, Virginia, that is listed on the Commonwealth's priority list of impaired streams for violations of the fecal coliform bacteria standard. Beyond developing this multiple-tracer approach for locating sources of sewage inputs to Accotink Creek, the second objective of the study was to demonstrate how the multiple-tracer approach can be applied to other streams affected by sewage sources. The tracers used in this study were separated into indicator tracers, which are relatively simple and inexpensive to apply, and confirmatory tracers, which are relatively difficult and expensive to analyze. Indicator tracers include fecal coliform bacteria, surfactants, boron, chloride, chloride/bromide ratio, specific conductance, dissolved oxygen, turbidity, and water temperature. Confirmatory tracers include 13 organic compounds that are associated with human waste, including caffeine, cotinine, triclosan, a number of detergent metabolites, several fragrances, and several plasticizers. To identify sources of sewage to Accotink Creek, a detailed investigation of the Accotink Creek main channel, tributaries, and flowing storm drains was undertaken from 2001 to 2004. Sampling was conducted in a series of eight synoptic sampling events, each of which began at the most downstream site and extended upstream through the watershed and into the headwaters of each tributary. Using the synoptic sampling approach, 149 sites were sampled at least one time for indicator tracers; 52 of these sites also were sampled for confirmatory tracers at least one time. Through the analysis of multiple-tracer levels in the synoptic samples, three major sewage sources to the Accotink Creek stream network were identified, and several other minor sewage sources to the Accotink Creek system likely deserve additional investigation. Near the end of the synoptic sampling activities, three additional sampling methods were used to gain better understanding of the potential for sewage sources to the watershed. These additional sampling methods included optical brightener monitoring, intensive stream sampling using automated samplers, and additional sampling of several storm-drain networks. The samples obtained by these methods provided further understanding of possible sewage sources to the streams and a better understanding of the variability in the tracer concentrations at a given sampling site. Collectively, these additional sampling methods were a valuable complement to the synoptic sampling approach that was used for the bulk of this study. The study results provide an approach for local authorities to use in applying a relatively simple and inexpensive collection of tracers to locate sewage sources to streams. Although this multiple-tracer approach is effective in detecting sewage sources to streams, additional research is needed to better detect extremely low-volume sewage sources and better enable local authorities to identify the specific sources of the sewage once it is detected in a stream reach.

  9. Use of 222Rn as natural tracer for LNAPL quantification and recovery efficiency in a crude-oil contaminated aquifer

    NASA Astrophysics Data System (ADS)

    Ponsin, Violaine; Chablais, Amélie; Dumont, Julien; Cardetti, Marc; Radakovitch, Olivier; Höhener, Patrick

    2014-05-01

    In august 2009, five hectares of the pristine gravel aquifer of Crau in southern France were contaminated by 5,100 m3 of crude oil due to the sudden break of a pipeline. The remediation of this site is still ongoing and consists in replacement and off-site disposal of contaminated topsoils, plume management by hydraulic groundwater barriers with re-injection of activated charcoal-treated waters, and dual-phase LNAPL extraction in the source zone. It is anticipated to stop these remediation actions when the rate of hydrocarbon extraction becomes inefficient. The volume of LNAPL is estimated between 100 and 1000 m3. A more accurate estimation is needed for the implementation of natural attenuation once physical treatment is discontinued. 222Rn has been introduced as a natural tracer for the quantification of LNAPL saturation in porous media under natural gradient conditions (Hunkeler et al., 1997; Semprini et al., 2000; Schubert et al., 2007). The objective of this study was to investigate whether 222Rn in groundwater can be used as a tracer for LNAPL quantification at a field site treated by LNAPL removal. To this end, groundwater samples were obtained in pristine monitoring wells from upgradient the contamination using submersible electric pumps, and in LNAPL recovery wells. There, samples were obtained from the tap on the hard PVC tubing used for pumping groundwater to the treatment facility. For 222Rn analysis, flasks of 250 mL were gently filled and were capped thereafter without permitting air bubbles. The flasks were analysed within 6 to 24 hours. The 222Rn activity of groundwater was measured by a Rn detector (RAD7-Durridge, Co. Inc.). The measurements were spaced over more than 15 months in order to account for seasonal changes. Each well was sampled at least 3 times. In pristine groundwater, the radon activity was relatively constant and remained always > 14 Bq/L. The radon activities in the groundwater of source zone wells were also relatively constant and the mean activities were generally significantly lower than upgradient. This is due to partitioning into the oil phase. Decreases were correlated with NAPL recovery efficiency. The laboratory-determined crude oil-water partitioning coefficient of 38,5 ± 2,9 was used for estimating LNAPL saturation in each recovery well. However, extrapolations of LNAPL saturations to whole-site oil volume estimations are difficult since at low water tables, the volume in the capillary fringe is not assessed. Nevertheless, we find that 222Rn is a useful and cheap groundwater tracer for finding zones of good LNAPL recovery in a heavily pumped aquifer. Hunkeler, D., E. Hoehn, P. Höhener and J. Zeyer, 1997. 222Rn as a partitioning tracer to detect mineral oil contaminations: laboratory experiments and field study. Environmental Science and Technology 31, 3180-3187. Semprini, L., O.S. Hopkins and B.R. Tasker, 2000. Laboratory, field and modeling studies of radon-222 as a natural tracer for monitoring NAPL contamination. Transport in Porous Media 38, 223-240. Schubert, M., A. Paschke, S. Lau, W. Geyer and K. Knöller, 2007. Radon as a naturally occurring tracer for the assessment of residual NAPL contamination of aquifers. Environmental Pollution 145, 920-927.

  10. Predicting Statistical Response and Extreme Events in Uncertainty Quantification through Reduced-Order Models

    NASA Astrophysics Data System (ADS)

    Qi, D.; Majda, A.

    2017-12-01

    A low-dimensional reduced-order statistical closure model is developed for quantifying the uncertainty in statistical sensitivity and intermittency in principal model directions with largest variability in high-dimensional turbulent system and turbulent transport models. Imperfect model sensitivity is improved through a recent mathematical strategy for calibrating model errors in a training phase, where information theory and linear statistical response theory are combined in a systematic fashion to achieve the optimal model performance. The idea in the reduced-order method is from a self-consistent mathematical framework for general systems with quadratic nonlinearity, where crucial high-order statistics are approximated by a systematic model calibration procedure. Model efficiency is improved through additional damping and noise corrections to replace the expensive energy-conserving nonlinear interactions. Model errors due to the imperfect nonlinear approximation are corrected by tuning the model parameters using linear response theory with an information metric in a training phase before prediction. A statistical energy principle is adopted to introduce a global scaling factor in characterizing the higher-order moments in a consistent way to improve model sensitivity. Stringent models of barotropic and baroclinic turbulence are used to display the feasibility of the reduced-order methods. Principal statistical responses in mean and variance can be captured by the reduced-order models with accuracy and efficiency. Besides, the reduced-order models are also used to capture crucial passive tracer field that is advected by the baroclinic turbulent flow. It is demonstrated that crucial principal statistical quantities like the tracer spectrum and fat-tails in the tracer probability density functions in the most important large scales can be captured efficiently with accuracy using the reduced-order tracer model in various dynamical regimes of the flow field with distinct statistical structures.

  11. CXTFIT/Excel A modular adaptable code for parameter estimation, sensitivity analysis and uncertainty analysis for laboratory or field tracer experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Guoping; Mayes, Melanie; Parker, Jack C

    2010-01-01

    We implemented the widely used CXTFIT code in Excel to provide flexibility and added sensitivity and uncertainty analysis functions to improve transport parameter estimation and to facilitate model discrimination for multi-tracer experiments on structured soils. Analytical solutions for one-dimensional equilibrium and nonequilibrium convection dispersion equations were coded as VBA functions so that they could be used as ordinary math functions in Excel for forward predictions. Macros with user-friendly interfaces were developed for optimization, sensitivity analysis, uncertainty analysis, error propagation, response surface calculation, and Monte Carlo analysis. As a result, any parameter with transformations (e.g., dimensionless, log-transformed, species-dependent reactions, etc.) couldmore » be estimated with uncertainty and sensitivity quantification for multiple tracer data at multiple locations and times. Prior information and observation errors could be incorporated into the weighted nonlinear least squares method with a penalty function. Users are able to change selected parameter values and view the results via embedded graphics, resulting in a flexible tool applicable to modeling transport processes and to teaching students about parameter estimation. The code was verified by comparing to a number of benchmarks with CXTFIT 2.0. It was applied to improve parameter estimation for four typical tracer experiment data sets in the literature using multi-model evaluation and comparison. Additional examples were included to illustrate the flexibilities and advantages of CXTFIT/Excel. The VBA macros were designed for general purpose and could be used for any parameter estimation/model calibration when the forward solution is implemented in Excel. A step-by-step tutorial, example Excel files and the code are provided as supplemental material.« less

  12. ImmunoPET with Anti-Mesothelin Antibody in Patients with Pancreatic and Ovarian Cancer before Anti-Mesothelin Antibody-Drug Conjugate Treatment.

    PubMed

    Lamberts, Laetitia E; Menke-van der Houven van Oordt, Catharina W; ter Weele, Eva J; Bensch, Frederike; Smeenk, Michiel M; Voortman, Johannes; Hoekstra, Otto S; Williams, Simon P; Fine, Bernard M; Maslyar, Daniel; de Jong, Johan R; Gietema, Jourik A; Schröder, Carolien P; Bongaerts, Alphons H H; Lub-de Hooge, Marjolijn N; Verheul, Henk M W; Sanabria Bohorquez, Sandra M; Glaudemans, Andor W J M; de Vries, Elisabeth G E

    2016-04-01

    Mesothelin (MSLN) is frequently overexpressed in pancreatic and ovarian cancers, making it a potential drug target. We performed an (89)Zr-PET imaging study with MMOT0530A, a MSLN antibody, in conjunction with a phase I study with the antibody-drug conjugate DMOT4039A, containing MMOT0530A bound to MMAE. The aim was to study antibody tumor uptake, whole-body distribution, and relation between uptake, response to treatment, and MSLN expression. Before DMOT4039A treatment, patients received 37 MBq (89)Zr-MMOT0530A followed by PET/CT imaging 2, 4, and 7 days postinjection. Tracer uptake was expressed as standardized uptake value (SUV). MSLN expression was determined with immunohistochemistry (IHC) on archival tumor tissue. Eleven patients were included, 7 with pancreatic and 4 with ovarian cancer. IHC MSLN expression varied from absent to strong. Suitable tracer antibody dose was 10 mg MMOT0530A and optimal imaging time was 4 and 7 days postinjection. Tumor tracer uptake occurred in 37 lesions with mean SUVmax of 13.1 (±7.5) on PET 4 days postinjection, with 11.5 (±7.5) in (N= 17) pancreatic and 14.5 (±8.7) in (N= 20) ovarian cancer lesions. Within patients, a mean 2.4-fold (±1.10) difference in uptake between tumor lesions existed. Uptake in blood, liver, kidneys, spleen, and intestine reflected normal antibody distribution. Tracer tumor uptake was correlated to IHC. Best response to DMOT4039A was partial response in one patient. With (89)Zr-MMOT0530A-PET, pancreatic and ovarian cancer lesions as well as antibody biodistribution could be visualized. This technique can potentially guide individualized antibody-based treatment. ©2015 American Association for Cancer Research.

  13. Reionization and CMB non-Gaussianity

    NASA Astrophysics Data System (ADS)

    Munshi, D.; Corasaniti, P. S.; Coles, P.; Heavens, A.; Pandolfi, S.

    2014-08-01

    We show how cross-correlating a high-redshift external tracer field, such as the 21-cm neutral hydrogen distribution and product maps involving cosmic microwave background (CMB) temperature and polarization fields, that probe mixed bispectrum involving these fields, can help to determine the reionization history of the Universe, beyond what can be achieved from cross-spectrum analysis. Taking clues from recent studies for the detection of primordial non-Gaussianity, we develop a set of estimators that can study reionization using a power spectrum associated with the bispectrum (or skew-spectrum). We use the matched filtering inherent in this method to investigate different reionization histories. We check to what extent they can be used to rule out various models of reionization and study cross-contamination from different sources such as the lensing of the CMB. The estimators can be fine-tuned to optimize study of a specific reionization history. We consider three different types of tracers in our study, namely: proto-galaxies; 21-cm maps of neutral hydrogen; and quasars. We also consider four alternative models of reionization. We find that the cumulative signal-to-noise ratio (S/N) for detection at ℓmax = 2000 can reach O(70) for cosmic variance limited all-sky experiments. Combining 100 GHz, 143 GHz and 217 GHz channels of the Planck experiment, we find that the S/N lies in the range O(5)-O(35). The S/N depends on the specific choice of a tracer field, and multiple tracers can be effectively used to map out the entire reionization history with reasonable S/N. Contamination from weak lensing is investigated and found to be negligible, and the effects of Thomson scattering from patchy reionization are also considered.

  14. Rapid Multi-Tracer PET Tumor Imaging With F-FDG and Secondary Shorter-Lived Tracers.

    PubMed

    Black, Noel F; McJames, Scott; Kadrmas, Dan J

    2009-10-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer (62)Cu - PTSM (blood flow) + (62)Cu - ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging (18)F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K(1), K(net)) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K(1) and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques.

  15. Rapid Multi-Tracer PET Tumor Imaging With 18F-FDG and Secondary Shorter-Lived Tracers

    PubMed Central

    Black, Noel F.; McJames, Scott; Kadrmas, Dan J.

    2009-01-01

    Rapid multi-tracer PET, where two to three PET tracers are rapidly scanned with staggered injections, can recover certain imaging measures for each tracer based on differences in tracer kinetics and decay. We previously showed that single-tracer imaging measures can be recovered to a certain extent from rapid dual-tracer 62Cu – PTSM (blood flow) + 62Cu — ATSM (hypoxia) tumor imaging. In this work, the feasibility of rapidly imaging 18F-FDG plus one or two of these shorter-lived secondary tracers was evaluated in the same tumor model. Dynamic PET imaging was performed in four dogs with pre-existing tumors, and the raw scan data was combined to emulate 60 minute long dual- and triple-tracer scans, using the single-tracer scans as gold standards. The multi-tracer data were processed for static (SUV) and kinetic (K1, Knet) endpoints for each tracer, followed by linear regression analysis of multi-tracer versus single-tracer results. Static and quantitative dynamic imaging measures of FDG were both accurately recovered from the multi-tracer scans, closely matching the single-tracer FDG standards (R > 0.99). Quantitative blood flow information, as measured by PTSM K1 and SUV, was also accurately recovered from the multi-tracer scans (R = 0.97). Recovery of ATSM kinetic parameters proved more difficult, though the ATSM SUV was reasonably well recovered (R = 0.92). We conclude that certain additional information from one to two shorter-lived PET tracers may be measured in a rapid multi-tracer scan alongside FDG without compromising the assessment of glucose metabolism. Such additional and complementary information has the potential to improve tumor characterization in vivo, warranting further investigation of rapid multi-tracer techniques. PMID:20046800

  16. A PET Tracer for Brain α2C Adrenoceptors, (11)C-ORM-13070: Radiosynthesis and Preclinical Evaluation in Rats and Knockout Mice.

    PubMed

    Arponen, Eveliina; Helin, Semi; Marjamäki, Päivi; Grönroos, Tove; Holm, Patrik; Löyttyniemi, Eliisa; Någren, Kjell; Scheinin, Mika; Haaparanta-Solin, Merja; Sallinen, Jukka; Solin, Olof

    2014-07-01

    We report the development of a PET tracer for α2C adrenoceptor imaging and its preliminary preclinical evaluation. α2C adrenoceptors in the human brain may be involved in various neuropsychiatric disorders, such as depression, schizophrenia, and neurodegenerative diseases. PET tracers are needed for imaging of this receptor system in vivo. High-specific-activity (11)C-ORM-13070 (1-[(S)-1-(2,3-dihydrobenzo[1,4]dioxin-2-yl)methyl]-4-(3-(11)C-methoxymethylpyridin-2-yl)-piperazine) was synthesized by (11)C-methylation of O-desmethyl-ORM-13070 with (11)C-methyl triflate, which was prepared from cyclotron-produced (11)C-methane via (11)C-methyl iodide. Rats and mice were investigated in vivo with PET and ex vivo with autoradiography. The specificity of (11)C-ORM-13070 binding to α2 adrenoceptors was demonstrated in rats pretreated with atipamezole, an α2 adrenoceptor antagonist. The α2C adrenoceptor selectivity of the tracer was determined by comparing tracer binding in wild-type and α2A- and α2AC adrenoceptor knockout (KO) mice. (11)C-ORM-13070 and its radioactive metabolites in rat plasma and brain tissue were analyzed with radio-high-performance liquid chromatography and mass spectroscopy. Human radiation dose estimates were extrapolated from rat biodistribution data. The radiochemical yield, calculated from initial cyclotron-produced (11)C-methane, was 9.6% ± 2.7% (decay-corrected to end of bombardment). The specific activity of the product was 640 ± 390 GBq/μmol (decay-corrected to end of synthesis). The radiochemical purity exceeded 99% in all syntheses. The highest levels of tracer binding were observed in the striatum and olfactory tubercle of rats and control and α2A KO mice-that is, in the brain regions known to contain the highest densities of α2C adrenoceptors. In rats pretreated with atipamezole and in α2AC KO mice, (11)C tracer binding in the striatum and olfactory tubercle was low, similar to that of the frontal cortex and thalamus, regions with low densities of α2C adrenoceptors. Two radioactive metabolites were found in rat plasma, but only one of them was found in the brain; their identity was not revealed. The estimated effective radiation dose was comparable with the average exposure level in PET studies with (11)C tracers. An efficient method for the radiosynthesis of (11)C-ORM-13070 was developed. (11)C-ORM-13070 emerged as a potential novel radiotracer for in vivo imaging of brain α2C adrenoceptors. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. Correlation of FMISO simulations with pimonidazole-stained tumor xenografts: A question of O{sub 2} consumption?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wack, L. J., E-mail: linda-jacqueline.wack@med.uni

    Purpose: To compare a dedicated simulation model for hypoxia PET against tumor microsections stained for different parameters of the tumor microenvironment. The model can readily be adapted to a variety of conditions, such as different human head and neck squamous cell carcinoma (HNSCC) xenograft tumors. Methods: Nine different HNSCC tumor models were transplanted subcutaneously into nude mice. Tumors were excised and immunoflourescently labeled with pimonidazole, Hoechst 33342, and CD31, providing information on hypoxia, perfusion, and vessel distribution, respectively. Hoechst and CD31 images were used to generate maps of perfused blood vessels on which tissue oxygenation and the accumulation of themore » hypoxia tracer FMISO were mathematically simulated. The model includes a Michaelis–Menten relation to describe the oxygen consumption inside tissue. The maximum oxygen consumption rate M{sub 0} was chosen as the parameter for a tumor-specific optimization as it strongly influences tracer distribution. M{sub 0} was optimized on each tumor slice to reach optimum correlations between FMISO concentration 4 h postinjection and pimonidazole staining intensity. Results: After optimization, high pixel-based correlations up to R{sup 2} = 0.85 were found for individual tissue sections. Experimental pimonidazole images and FMISO simulations showed good visual agreement, confirming the validity of the approach. Median correlations per tumor model varied significantly (p < 0.05), with R{sup 2} ranging from 0.20 to 0.54. The optimum maximum oxygen consumption rate M{sub 0} differed significantly (p < 0.05) between tumor models, ranging from 2.4 to 5.2 mm Hg/s. Conclusions: It is feasible to simulate FMISO distributions that match the pimonidazole retention patterns observed in vivo. Good agreement was obtained for multiple tumor models by optimizing the oxygen consumption rate, M{sub 0}, whose optimum value differed significantly between tumor models.« less

  18. Optimized Time-Gated Fluorescence Spectroscopy for the Classification and Recycling of Fluorescently Labeled Plastics.

    PubMed

    Fomin, Petr; Zhelondz, Dmitry; Kargel, Christian

    2017-05-01

    For the production of high-quality parts from recycled plastics, a very high purity of the plastic waste to be recycled is mandatory. The incorporation of fluorescent tracers ("markers") into plastics during the manufacturing process helps overcome typical problems of non-tracer based optical classification methods. Despite the unique emission spectra of fluorescent markers, the classification becomes difficult when the host plastics exhibit (strong) autofluorescence that spectrally overlaps the marker fluorescence. Increasing the marker concentration is not an option from an economic perspective and might also adversely affect the properties of the plastics. A measurement approach that suppresses the autofluorescence in the acquired signal is time-gated fluorescence spectroscopy (TGFS). Unfortunately, TGFS is associated with a lower signal-to-noise (S/N) ratio, which results in larger classification errors. In order to optimize the S/N ratio we investigate and validate the best TGFS parameters-derived from a model for the fluorescence signal-for plastics labeled with four specifically designed fluorescent markers. In this study we also demonstrate the implementation of TGFS on a measurement and classification prototype system and determine its performance. Mean values for a sensitivity of [Formula: see text] = 99.93% and precision [Formula: see text] = 99.80% were achieved, proving that a highly reliable classification of plastics can be achieved in practice.

  19. Nitrate turnover in a peat soil under drained and rewetted conditions: results from a [(15)N]nitrate-bromide double-tracer study.

    PubMed

    Russow, Rolf; Tauchnitz, Nadine; Spott, Oliver; Mothes, Sibylle; Bernsdorf, Sabine; Meissner, Ralph

    2013-01-01

    Under natural conditions, peatlands are generally nitrate-limited. However, recent concerns about an additional N input into peatlands by atmospheric N deposition have highlighted the risk of an increased denitrification activity and hence the likelihood of a rise of emissions of the greenhouse gas nitrous oxide. Therefore, the aim of the present study was to investigate the turnover of added nitrate in a drained and a rewetted peatland using a [(15)N]nitrate-bromide double-tracer method. The double-tracer method allows a separation between physical effects (dilution, dispersion and dislocation) and microbial and chemical nitrate transformation by comparing with the conservative Br(-) tracer. In the drained peat site, low NO3(-) consumption rates have been observed. In contrast, NO3(-) consumption at the rewetted peat site rises rapidly to about 100% within 4 days after tracer application. Concomitantly, the (15)N abundances of nitrite and ammonium in soil water increased and lead to the conclusion that, besides commonly known NO3(-) reduction to nitrite (i.e. denitrification), a dissimilatory nitrate reduction to ammonium has simultaneously taken place. The present study reveals that increasing NO3(-) inputs into rewetted peatlands via atmospheric deposition results in a rapid NO3(-) consumption, which could lead to an increase in N2O emissions into the atmosphere.

  20. Evaluation of N-[(11)C]methyl-AMD3465 as a PET tracer for imaging of CXCR4 receptor expression in a C6 glioma tumor model.

    PubMed

    Hartimath, S V; van Waarde, A; Dierckx, R A J O; de Vries, E F J

    2014-11-03

    The chemokine receptor CXCR4 and its ligand CXCL12 play an important role in tumor progression and metastasis. CXCR4 receptors are expressed by many cancer types and provide a potential target for treatment. Noninvasive detection of CXCR4 may aid diagnosis and improve therapy selection. It has been demonstrated in preclinical studies that positron emission tomography (PET) with a radiolabeled small molecule could enable noninvasive monitoring of CXCR4 expression. Here, we prepared N-[(11)C]methyl-AMD3465 as a new PET tracer for CXCR4. N-[(11)C]Methyl-AMD3465 was readily prepared by N-methylation with [(11)C]CH3OTf. The tracer was obtained in a 60 ± 2% yield (decay corrected), the purity of the tracer was >99%, and specific activity was 47 ± 14 GBq/μmol. Tracer stability was tested in vitro using liver microsomes and rat plasma; excellent stability was observed. The tracer was evaluated in rat C6 glioma and human PC-3 cell lines. In vitro cellular uptake of N-[(11)C]methyl-AMD3465 was receptor mediated. The effect of transition metal ions (Cu(2+), Ni(2+), and Zn(2+)) on cellular binding was examined in C6 cells, and the presence of these ions increased the cellular binding of the tracer 9-, 7-, and 3-fold, respectively. Ex vivo biodistribution and PET imaging of N-[(11)C]methyl-AMD3465 were performed in rats with C6 tumor xenografts. Both PET and biodistribution studies demonstrated specific accumulation of the tracer in the tumor (SUV 0.6 ± 0.2) and other CXCR4 expressing organs, such as lymph node (1.5 ± 0.2), liver (8.9 ± 1.0), bone marrow (1.0 ± 0.3), and spleen (1.0 ± 0.1). Tumor uptake was significantly reduced (66%, p < 0.01) after pretreatment with Plerixafor (AMD3100). Biodistribution data indicates a tumor-to-muscle ratio of 7.85 and tumor-to-plasma ratio of 1.14, at 60 min after tracer injection. Our data demonstrated that N-[(11)C]methyl-AMD3465 is capable of detecting physiologic CXCR4 expression in tumors and other CXCR4 expressing tissues. These results warrant further evaluation of N-[(11)C]methyl-AMD3465 as a potential PET tracer for CXCR4 receptor imaging.

  1. [⁹⁹mTc]O₂-AMD3100 as a SPECT tracer for CXCR4 receptor imaging.

    PubMed

    Hartimath, Siddesh V; Domanska, Urszula M; Walenkamp, Annemiek M E; Rudi A J O, Dierckx; de Vries, Erik F J

    2013-05-01

    CXCR4 plays an important role in HIV infection, tumor progression, neurogenesis, and inflammation. In-vivo imaging of CXCR4 could provide more insight in the role of this receptor in health and disease. The aim of this study was to investigate [(99m)Tc]O₂-AMD3100 as a potential SPECT tracer for imaging of CXCR4. AMD3100 was labelled with [(99m)Tc]pertechnetate. A cysteine challenge assay was performed to test the tracer stability. Heterologous and homologous receptor binding assay and internalization assay were performed in CXCR4 expressing Jurkat-T cells. Ex vivo biodistribution was studied in healthy mice at 30, 60, and 120 min after tracer injection. Tumor uptake of the tracer was determined by microSPECT imaging in nude mice xenografted with human PC-3 prostate tumor. Specificity of tracer uptake was determined by blocking studies using an excess of unlabelled AMD3100. AMD3100 was labelled with technetium-99m with a radiochemical yield of >98%. The tracer was stable in PBS and mouse plasma for at least 6h at 37 °C. Heterologous and homologous binding assays with AMD3100 showed IC50 values of 240 ± 10 μM, and 92 ± 5 μM for [(125)I]SDF-1α and [(99m)Tc]O₂-AMD3100 respectively, with negligible receptor internalisation. The tracer showed high uptake in liver, lungs, spleen, thymus, intestine and bone. Blocking dose of AMD3100.8HCl (20mg/kg) decreased the uptake in these organs (p<0.05). [(99m)Tc]O2-AMD3100 showed specific tumor accumulation in mice bearing PC-3 xenografts model. Time activity curves (TAC) in AMD3100 pre-treated animals tracer showed 1.7 times less tumor uptake as compared to control animals (p<0.05). [(99m)Tc]O2-AMD3100 is readily labelled, is stable in plasma and displays a favourable binding affinity for the CXCR4 receptors. [(99m)Tc O₂-AMD3100 shows specific binding in organs with high CXCR4 expression and in CXCR4 positive tumors. These results justify further evaluation of this radiopharmaceutical as a potential biomarker for the non-invasive imaging of CXCR4 receptors. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Experimental design for estimating parameters of rate-limited mass transfer: Analysis of stream tracer studies

    USGS Publications Warehouse

    Wagner, Brian J.; Harvey, Judson W.

    1997-01-01

    Tracer experiments are valuable tools for analyzing the transport characteristics of streams and their interactions with shallow groundwater. The focus of this work is the design of tracer studies in high-gradient stream systems subject to advection, dispersion, groundwater inflow, and exchange between the active channel and zones in surface or subsurface water where flow is stagnant or slow moving. We present a methodology for (1) evaluating and comparing alternative stream tracer experiment designs and (2) identifying those combinations of stream transport properties that pose limitations to parameter estimation and therefore a challenge to tracer test design. The methodology uses the concept of global parameter uncertainty analysis, which couples solute transport simulation with parameter uncertainty analysis in a Monte Carlo framework. Two general conclusions resulted from this work. First, the solute injection and sampling strategy has an important effect on the reliability of transport parameter estimates. We found that constant injection with sampling through concentration rise, plateau, and fall provided considerably more reliable parameter estimates than a pulse injection across the spectrum of transport scenarios likely encountered in high-gradient streams. Second, for a given tracer test design, the uncertainties in mass transfer and storage-zone parameter estimates are strongly dependent on the experimental Damkohler number, DaI, which is a dimensionless combination of the rates of exchange between the stream and storage zones, the stream-water velocity, and the stream reach length of the experiment. Parameter uncertainties are lowest at DaI values on the order of 1.0. When DaI values are much less than 1.0 (owing to high velocity, long exchange timescale, and/or short reach length), parameter uncertainties are high because only a small amount of tracer interacts with storage zones in the reach. For the opposite conditions (DaI ≫ 1.0), solute exchange rates are fast relative to stream-water velocity and all solute is exchanged with the storage zone over the experimental reach. As DaI increases, tracer dispersion caused by hyporheic exchange eventually reaches an equilibrium condition and storage-zone exchange parameters become essentially nonidentifiable.

  3. Dynamic dual-isotope molecular imaging elucidates principles for optimizing intrathecal drug delivery

    PubMed Central

    Wolf, Daniel A.; Hesterman, Jacob Y.; Sullivan, Jenna M.; Orcutt, Kelly D.; Silva, Matthew D.; Lobo, Merryl; Wellman, Tyler; Hoppin, Jack

    2016-01-01

    The intrathecal (IT) dosing route offers a seemingly obvious solution for delivering drugs directly to the central nervous system. However, gaps in understanding drug molecule behavior within the anatomically and kinetically unique environment of the mammalian IT space have impeded the establishment of pharmacokinetic principles for optimizing regional drug exposure along the neuraxis. Here, we have utilized high-resolution single-photon emission tomography with X-ray computed tomography to study the behavior of multiple molecular imaging tracers following an IT bolus injection, with supporting histology, autoradiography, block-face tomography, and MRI. Using simultaneous dual-isotope imaging, we demonstrate that the regional CNS tissue exposure of molecules with varying chemical properties is affected by IT space anatomy, cerebrospinal fluid (CSF) dynamics, CSF clearance routes, and the location and volume of the injected bolus. These imaging approaches can be used across species to optimize the safety and efficacy of IT drug therapy for neurological disorders. PMID:27699254

  4. Experimental study of ERT monitoring ability to measure solute dispersion.

    PubMed

    Lekmine, Grégory; Pessel, Marc; Auradou, Harold

    2012-01-01

    This paper reports experimental measurements performed to test the ability of electrical resistivity tomography (ERT) imaging to provide quantitative information about transport parameters in porous media such as the dispersivity α, the mixing front velocity u, and the retardation factor R(f) associated with the sorption or trapping of the tracers in the pore structure. The flow experiments are performed in a homogeneous porous column placed between two vertical set of electrodes. Ionic and dyed tracers are injected from the bottom of the porous media over its full width. Under such condition, the mixing front is homogeneous in the transverse direction and shows an S-shape variation in the flow direction. The transport parameters are inferred from the variation of the concentration curves and are compared with data obtained from video analysis of the dyed tracer front. The variations of the transport parameters obtained from an inversion performed by the Gauss-Newton method applied on smoothness-constrained least-squares are studied in detail. While u and R(f) show a relatively small dependence on the inversion procedure, α is strongly dependent on the choice of the inversion parameters. Comparison with the video observations allows for the optimization of the parameters; these parameters are found to be robust with respect to changes in the flow condition and conductivity contrast. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  5. Model-Based Design of Long-Distance Tracer Transport Experiments in Plants.

    PubMed

    Bühler, Jonas; von Lieres, Eric; Huber, Gregor J

    2018-01-01

    Studies of long-distance transport of tracer isotopes in plants offer a high potential for functional phenotyping, but so far measurement time is a bottleneck because continuous time series of at least 1 h are required to obtain reliable estimates of transport properties. Hence, usual throughput values are between 0.5 and 1 samples h -1 . Here, we propose to increase sample throughput by introducing temporal gaps in the data acquisition of each plant sample and measuring multiple plants one after each other in a rotating scheme. In contrast to common time series analysis methods, mechanistic tracer transport models allow the analysis of interrupted time series. The uncertainties of the model parameter estimates are used as a measure of how much information was lost compared to complete time series. A case study was set up to systematically investigate different experimental schedules for different throughput scenarios ranging from 1 to 12 samples h -1 . Selected designs with only a small amount of data points were found to be sufficient for an adequate parameter estimation, implying that the presented approach enables a substantial increase of sample throughput. The presented general framework for automated generation and evaluation of experimental schedules allows the determination of a maximal sample throughput and the respective optimal measurement schedule depending on the required statistical reliability of data acquired by future experiments.

  6. Tracking the fate of nitrate through pulse-flow wetlands: A mesocosm scale 15N enrichment tracer study

    USGS Publications Warehouse

    Messer, Tiffany L.; Burchell, Michael R.; Böhlke, John Karl; Tobias, Craig R.

    2017-01-01

    Quantitative information about the fate of applied nitrate (NO3-N) in pulse-flow constructed wetlands is essential for designing wetland treatment systems and assessing their nitrogen removal services for agricultural and stormwater applications. Although many studies have documented NO3-N losses in wetlands, controlled experiments indicating the relative importance of different processes and N sinks are scarce. In the current study, 15NO3-N isotope enrichment tracer experiments were conducted in wetland mesocosms of two different wetland soil types at two realistic agricultural NO3-N source loads. The 15N label was traced from the source NO3-N into plant biomass, soil (including organic matter and ammonium), and N-gas constituents over 7–10 day study periods. All sinks responded positively to higher NO3-N loading. Plant uptake exceeded denitrification 2–3 fold in the low NO3-N loading experiments, while both fates were nearly equivalent in the high loading experiments. One to two years later, soils largely retained the assimilated tracer N, whereas plants had lost much of it. Results demonstrated that plant and microbial assimilation in the soil (temporary N sinks) can exceed denitrification (permanent N loss) in pulse-flow environments and must be considered by wetland designers and managers for optimizing nitrogen removal potential.

  7. Research on large spatial coordinate automatic measuring system based on multilateral method

    NASA Astrophysics Data System (ADS)

    Miao, Dongjing; Li, Jianshuan; Li, Lianfu; Jiang, Yuanlin; Kang, Yao; He, Mingzhao; Deng, Xiangrui

    2015-10-01

    To measure the spatial coordinate accurately and efficiently in large size range, a manipulator automatic measurement system which based on multilateral method is developed. This system is divided into two parts: The coordinate measurement subsystem is consists of four laser tracers, and the trajectory generation subsystem is composed by a manipulator and a rail. To ensure that there is no laser beam break during the measurement process, an optimization function is constructed by using the vectors between the laser tracers measuring center and the cat's eye reflector measuring center, then an orientation automatically adjust algorithm for the reflector is proposed, with this algorithm, the laser tracers are always been able to track the reflector during the entire measurement process. Finally, the proposed algorithm is validated by taking the calibration of laser tracker for instance: the actual experiment is conducted in 5m × 3m × 3.2m range, the algorithm is used to plan the orientations of the reflector corresponding to the given 24 points automatically. After improving orientations of some minority points with adverse angles, the final results are used to control the manipulator's motion. During the actual movement, there are no beam break occurs. The result shows that the proposed algorithm help the developed system to measure the spatial coordinates over a large range with efficiency.

  8. [Is 3'-deoxy-3'- [18F] fluorothymidine ([18F]-FLT) the next tracer for routine clinical PET after R [18F]-FDG?].

    PubMed

    Couturier, Olivier; Leost, Françoise; Campone, Mario; Carlier, Thomas; Chatal, Jean-François; Hustinx, Roland

    2005-09-01

    Positron emission tomography (PET) with [18F]-FDG is now firmly established as a clinical tool in oncology. Its applications are however limited in some indications, due to the lack of specificity of its uptake mechanism for tumors, or the low avidity of some cancer types such as prostate. Alternative tracers are thus being developed, in order to fill up this void. Proliferation as a biological target is particularly attractive in cancer imaging. From that perspective, fluorothymidine ([18F]-FLT or FLT) has generated a strong interest among the scientific community, especially since the radiosynthesis process has been improved and simplified, thus making possible to envision a routine use for the tracer. This article aims at summarizing the status of the current scientific data regarding FLT. The uptake mechanism of FLT is well known, relying on the thymidine kinase 1 (TK1) enzymatic activity, and thus on DNA synthesis. Preclinical studies have shown a clear relationship between tracer accumulation and level of tumor proliferation, even though DNA salvage pathwayss intervene in the process and may complicate the interpretation of the results. Several clinical studies suggest a good specificity for tumor, albeit with a lower sensitivity than with FDG. In all likelihood however, the future of FLT lies in the evaluation of antitumor response and possibly the pretherapeutic prognostic characterization, rather than in the diagnosis and staging of malignancies. Although the scientific data regarding this issue remain limited, initial results are encouraging. Further significant work remains to be done in order to fully assess the clinical performances of the tracer, on the one hand, and to determine its place relative to FDG and other emerging tracers, on the other hand. Until these studies are completed, FLT should be considered as a promising tracer, but remaining at an experimental stage of its development.

  9. Using environmental tracer data to identify deep-aquifer, long-term flow patterns and recharge distributions in the Surat Basin, Queensland, Australia

    NASA Astrophysics Data System (ADS)

    Siade, A. J.; Suckow, A. O.; Morris, R.; Raiber, M.; Prommer, H.

    2017-12-01

    The calibration of regional groundwater flow models, including those investigating coal-seam gas (CSG) impacts in the Surat Basin, Australia, are not typically constrained using environmental tracers, although the use of such data can potentially provide significant reductions in predictive uncertainties. These additional sources of information can also improve the conceptualisation of flow systems and the quantification of groundwater fluxes. In this study, new multi-tracer data (14C, 39Ar, 81Kr, and 36Cl) were collected for the eastern recharge areas of the basin and within the deeper Hutton and Precipice Sandstone formations to complement existing environmental tracer data. These data were used to better understand the recharge mechanisms, recharge rates and the hydraulic properties associated with deep aquifer systems in the Surat Basin. Together with newly acquired pressure data documenting the response to the large-scale reinjection of highly treated CSG co-produced water, the environmental tracer data helped to improve the conceptualisation of the aquifer system, forming the basis for a more robust quantification of the long-term impacts of CSG-related activities. An existing regional scale MODFLOW-USG groundwater flow model of the area was used as the basis for our analysis of existing and new observation data. A variety of surrogate modelling approaches were used to develop simplified models that focussed on the flow and transport behaviour of the deep aquifer systems. These surrogate models were able to represent sub-system behaviour in terms of flow, multi-environmental tracer transport and the observed large-scale hydrogeochemical patterns. The incorporation of the environmental tracer data into the modelling framework provide an improved understanding of the flow regimes of the deeper aquifer systems as well as valuable information on how to reduce uncertainties in hydraulic properties where there is little or no historical observations of hydraulic heads.

  10. Non-input analysis for incomplete trapping irreversible tracer with PET.

    PubMed

    Ohya, Tomoyuki; Kikuchi, Tatsuya; Fukumura, Toshimitsu; Zhang, Ming-Rong; Irie, Toshiaki

    2013-07-01

    When using metabolic trapping type tracers, the tracers are not always trapped in the target tissue; i.e., some are completely trapped in the target, but others can be eliminated from the target tissue at a measurable rate. The tracers that can be eliminated are termed 'incomplete trapping irreversible tracers'. These incomplete trapping irreversible tracers may be clinically useful when the tracer β-value, the ratio of the tracer (metabolite) elimination rate to the tracer efflux rate, is under approximately 0.1. In this study, we propose a non-input analysis for incomplete trapping irreversible tracers based on the shape analysis (Shape), a non-input analysis used for irreversible tracers. A Monte Carlo simulation study based on experimental monkey data with two actual PET tracers (a complete trapping irreversible tracer [(11)C]MP4A and an incomplete trapping irreversible tracer [(18)F]FEP-4MA) was performed to examine the effects of the environmental error and the tracer elimination rate on the estimation of the k3-parameter (corresponds to metabolic rate) using Shape (original) and modified Shape (M-Shape) analysis. The simulation results were also compared with the experimental results obtained with the two PET tracers. When the tracer β-value was over 0.03, the M-Shape method was superior to the Shape method for the estimation of the k3-parameter. The simulation results were also in reasonable agreement with the experimental ones. M-Shape can be used as the non-input analysis of incomplete trapping irreversible tracers for PET study. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Prostate-Specific Membrane Antigen Expression in Distal Radius Fracture.

    PubMed

    Hoberück, Sebastian; Michler, Enrico; Kaiser, Daniel; Röhnert, Anne; Zöphel, Klaus; Kotzerke, Jörg

    2018-06-12

    A 79-year old man with prostate cancer under active surveillance for 5 years was referred for a PSMA-PET/MRI for re-evaluation because of a rising prostate-specific antigen value. PET/MRI revealed a ribbonlike tracer accumulation in a healing fracture of the distal radius. This case illustrates that PSMA expression may occur in healing bone fractures in the distal radius. It can be assumed that benign causes of tracer accumulations in the upper extremities are missed in PET/CT due to elevated position of the arms during image acquisition.

  12. Molecular Imaging of Activated Matrix Metalloproteinases in Vascular Remodeling

    PubMed Central

    Zhang, Jiasheng; Nie, Lei; Razavian, Mahmoud; Ahmed, Masood; Dobrucki, Lawrence W.; Asadi, Abolfazl; Edwards, D. Scott; Azure, Michael; Sinusas, Albert J.; Sadeghi, Mehran M.

    2008-01-01

    Background Matrix metalloproteinase (MMP) activation plays a key role in vascular remodeling. RP782 is a novel 111In –labeled tracer with specificity for activated MMPs. We hypothesized that RP782 can detect injury-induced vascular remodeling in vivo. Methods and Results Left common carotid artery injury was induced using a guide wire in apolipoprotein E-/- mice. Sham surgery was performed on the contralateral artery, which served as control for imaging experiments. Carotid wire injury led to significant hyperplasia and expansive remodeling over a period of 4 weeks. MMP activity detected by in-situ zymography, increased in response to injury and was maximal by 3-4 weeks after injury. RP782 (11.1 MBq) was injected intravenously to apolipoprotein E-/- mice at 1, 2, 3, and 4 weeks after left carotid injury. MicroSPECT imaging was performed at 2 hours and was followed by CT angiography to localize the carotid arteries. In vivo images revealed focal uptake of RP782 in the injured carotid artery at 2, 3 and 4 weeks. Increased tracer uptake in the injured artery was confirmed by quantitative autoradiography. Pretreatment with 50-fold excess non-labeled tracer significantly reduced RP782 uptake in injured carotids, demonstrating uptake specificity. Weekly changes in the vessel wall area closely paralleled and correlated with RP782 uptake (Spearman r=0.95, p=0.001). Conclusions Injury-induced MMP activation in the vessel wall can be detected by RP782 microSPECT/CT imaging in vivo. RP782 uptake tracks the hyperplastic process in vascular remodeling, and provides an opportunity to track the remodeling process in vivo. PMID:18936327

  13. [Correlation of substrate structure and hydraulic characteristics in subsurface flow constructed wetlands].

    PubMed

    Bai, Shao-Yuan; Song, Zhi-Xin; Ding, Yan-Li; You, Shao-Hong; He, Shan

    2014-02-01

    The correlation of substrate structure and hydraulic characteristics was studied by numerical simulation combined with experimental method. The numerical simulation results showed that the permeability coefficient of matrix had a great influence on hydraulic efficiency in subsurface flow constructed wetlands. The filler with a high permeability coefficient had a worse flow field distribution in the constructed wetland with single layer structure. The layered substrate structure with the filler permeability coefficient increased from surface to bottom could avoid the short-circuited flow and dead-zones, and thus, increased the hydraulic efficiency. Two parallel pilot-scale constructed wetlands were built according to the numerical simulation results, and tracer experiments were conducted to validate the simulation results. The tracer experiment result showed that hydraulic characteristics in the layered constructed wetland were obviously better than that in the single layer system, and the substrate effective utilization rates were 0.87 and 0.49, respectively. It was appeared that numerical simulation would be favorable for substrate structure optimization in subsurface flow constructed wetlands.

  14. Radiolabeled probes for imaging Alzheimer’s plaques

    NASA Astrophysics Data System (ADS)

    Kulkarni, P. V.; Arora, V.; Roney, A. C.; White, C.; Bennett, M.; Antich, P. P.; Bonte, F. J.

    2005-12-01

    Alzheimer's disease (AD) is a debilitating disease characterized by the presence of extra-cellular plaques and intra-cellular neurofibrillary tangles (NFTs) in the brain. The major protein component of these plaques is beta amyloid peptide (Aβ), a 40-42 amino acid peptide cleaved from amyloid precursor protein (APP) by β-secretase and a putative γ-secretase. We radioiodinated quinoline derivatives (clioquinol and oxine) and evaluated them as potential amyloid imaging agents based on their ability to cross the blood brain barrier (BBB) and on their selectivity to metal binding sites on amyloid plaques. The uptake of theses tracers in the brains of normal swiss-webster mice was rapid and so was the clearance. Selectivity was demonstrated by higher binding to AD brain homogenates compared to normal brain. Autoradiographic studies demonstrated the localization of the tracers in the plaque regions of the AD brain sections as well as in liver tissue with amyloidosis. Further optimization and evaluations would likely lead to development of these molecules as AD plaque imaging agents.

  15. Correlation of aeolian sediment transport measured by sand traps and fluorescent tracers

    NASA Astrophysics Data System (ADS)

    Cabrera, Laura L.; Alonso, Ignacio

    2010-03-01

    Two different methods, fluorescent tracers and vertical sand traps, were simultaneously used to carry out an aeolian sediment transport study designed to test the goodness of fluorescent tracers in aeolian environments. Field experiments were performed in a nebkha field close to Famara beach at Lanzarote Island (Canary Islands, Spain) in a sector where the dunes were between 0.5 and 0.8 m height and 1-2 m wide and the vegetal cover was approximately 22%. In this dune field the sediment supply comes from Famara beach and is blown by trade winds toward the south, where the vegetation acts as natural sediment traps. Wind data were obtained by means of four Aanderaa wind speed sensors and one Aanderaa vane, all them distributed in a vertical array from 0.1 to 4 m height for 27 h. The average velocity at 1 m height during the experiment was 5.26 m s - 1 with the wind direction from the north. The tracer was under wind influence for 90 min at midday. During this period two series of sand traps (T1 and T2) N, S, E and W oriented were used. Resultant transport rates were 0.0131 and 0.0184 kg m - 1 min - 1 respectively. Tracer collection was performed with a sticky tape to sample only surface sediments. Tagged grains were visually counted under UV light. The transport rate was computed from the centroid displacement, that moved 0.875 m southwards, and the depth of the active layer considered was the size of one single grain. Taking into account these data the transport rate was 0.0072 kg m - 1 min - 1 . The discrepancy in results between both methods is related to several factors, such as the thickness of the active layer and the grain size difference between the tagged and the native material.

  16. Multi-species constraint of anthropogenic and biogenic processes over North America during ACT-America summer 2016 and winter 2017 aircraft campaigns

    NASA Astrophysics Data System (ADS)

    Parazoo, N.; Bowman, K. W.; Kuai, L.; Liu, J.; Lee, M.; Baker, I. T.; Berry, J. A.; Davis, K. J.; Lauvaux, T.; DiGangi, J. P.; Sweeney, C.

    2017-12-01

    Multi-species measurements of CO, OCS, and SIF have the potential to attribute CO2 variability to productivity and anthropogenic emissions. ACT-America aircraft campaigns in summer 2016 and winter 2017 collected vertical profiles of these key species close to their sources, providing important constraints on CO2 sources across 3 unique regions in eastern North America. The CMS-Flux carbon cycle assimilation system uses satellite measurements of CO (MOPITT), CO2 (OCO-2), SIF (OCO-2), and OCS (TES) to determine regional CO2 sources due to fossil fuel emissions, biomass burning, and net biome exchange, providing independent flux constraints, and which can be propagated back to the atmosphere for direct comparison to aircraft data. Here, we evaluate tracer-tracer correlations between CO2, CO, and OCS from ACT-America aircraft data during fall and winter campaigns, and compare to posterior signals from CMS-Flux over the same period. To predict atmospheric OCS signals, we leverage mechanistic representations of OCS plant uptake and GPP in the SiB land surface model to determine OCS-GPP linear relationships, then use SIF optimized estimates of GPP to infer OCS fluxes. Our objectives in this study are 3 fold: (1) Determine consistency of regional source attributions from CMS-Flux with aircraft data from ACT-America; (2) Analyze observed (ACT-America) and predicted (CMS-Flux) tracer-tracer correlations across multiple seasons and regions to identify key biogenic and anthropogenic drivers; (3) Determine to what extent SIF and OCS are valid linear predictors of GPP spatial variability. Summertime evaluation of these tracers shows good correlation between OCS/CO2 and OCS/CO in the midwest but poorer correlation in the northeast possibly reflecting biogenic controls on CO2. Comparisons of observed and predicted CO and CO2 in the PBL with CMF-Flux data indicate positively correlated biases that reflect both transport and flux errors. These results are compared with the winter campaign data to better inform biogenic vs anthropogenic sources, and provide ensemble predictions of OCS from SiB and multi-satellite SIF constraints for more robust analysis of GPP variability.

  17. Tracer kinetic modelling for DCE-MRI quantification of subtle blood-brain barrier permeability.

    PubMed

    Heye, Anna K; Thrippleton, Michael J; Armitage, Paul A; Valdés Hernández, Maria Del C; Makin, Stephen D; Glatz, Andreas; Sakka, Eleni; Wardlaw, Joanna M

    2016-01-15

    There is evidence that subtle breakdown of the blood-brain barrier (BBB) is a pathophysiological component of several diseases, including cerebral small vessel disease and some dementias. Dynamic contrast-enhanced MRI (DCE-MRI) combined with tracer kinetic modelling is widely used for assessing permeability and perfusion in brain tumours and body tissues where contrast agents readily accumulate in the extracellular space. However, in diseases where leakage is subtle, the optimal approach for measuring BBB integrity is likely to differ since the magnitude and rate of enhancement caused by leakage are extremely low; several methods have been reported in the literature, yielding a wide range of parameters even in healthy subjects. We hypothesised that the Patlak model is a suitable approach for measuring low-level BBB permeability with low temporal resolution and high spatial resolution and brain coverage, and that normal levels of scanner instability would influence permeability measurements. DCE-MRI was performed in a cohort of mild stroke patients (n=201) with a range of cerebral small vessel disease severity. We fitted these data to a set of nested tracer kinetic models, ranking their performance according to the Akaike information criterion. To assess the influence of scanner drift, we scanned 15 healthy volunteers that underwent a "sham" DCE-MRI procedure without administration of contrast agent. Numerical simulations were performed to investigate model validity and the effect of scanner drift. The Patlak model was found to be most appropriate for fitting low-permeability data, and the simulations showed vp and K(Trans) estimates to be reasonably robust to the model assumptions. However, signal drift (measured at approximately 0.1% per minute and comparable to literature reports in other settings) led to systematic errors in calculated tracer kinetic parameters, particularly at low permeabilities. Our findings justify the growing use of the Patlak model in low-permeability states, which has the potential to provide valuable information regarding BBB integrity in a range of diseases. However, absolute values of the resulting tracer kinetic parameters should be interpreted with extreme caution, and the size and influence of signal drift should be measured where possible. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Tracer kinetic modelling for DCE-MRI quantification of subtle blood–brain barrier permeability

    PubMed Central

    Heye, Anna K.; Thrippleton, Michael J.; Armitage, Paul A.; Valdés Hernández, Maria del C.; Makin, Stephen D.; Glatz, Andreas; Sakka, Eleni; Wardlaw, Joanna M.

    2016-01-01

    There is evidence that subtle breakdown of the blood–brain barrier (BBB) is a pathophysiological component of several diseases, including cerebral small vessel disease and some dementias. Dynamic contrast-enhanced MRI (DCE-MRI) combined with tracer kinetic modelling is widely used for assessing permeability and perfusion in brain tumours and body tissues where contrast agents readily accumulate in the extracellular space. However, in diseases where leakage is subtle, the optimal approach for measuring BBB integrity is likely to differ since the magnitude and rate of enhancement caused by leakage are extremely low; several methods have been reported in the literature, yielding a wide range of parameters even in healthy subjects. We hypothesised that the Patlak model is a suitable approach for measuring low-level BBB permeability with low temporal resolution and high spatial resolution and brain coverage, and that normal levels of scanner instability would influence permeability measurements. DCE-MRI was performed in a cohort of mild stroke patients (n = 201) with a range of cerebral small vessel disease severity. We fitted these data to a set of nested tracer kinetic models, ranking their performance according to the Akaike information criterion. To assess the influence of scanner drift, we scanned 15 healthy volunteers that underwent a “sham” DCE-MRI procedure without administration of contrast agent. Numerical simulations were performed to investigate model validity and the effect of scanner drift. The Patlak model was found to be most appropriate for fitting low-permeability data, and the simulations showed vp and KTrans estimates to be reasonably robust to the model assumptions. However, signal drift (measured at approximately 0.1% per minute and comparable to literature reports in other settings) led to systematic errors in calculated tracer kinetic parameters, particularly at low permeabilities. Our findings justify the growing use of the Patlak model in low-permeability states, which has the potential to provide valuable information regarding BBB integrity in a range of diseases. However, absolute values of the resulting tracer kinetic parameters should be interpreted with extreme caution, and the size and influence of signal drift should be measured where possible. PMID:26477653

  19. Physiologically based pharmacokinetic modeling of (18)F-SiFAlin-Asp3-PEG1-TATE in AR42J tumor bearing mice.

    PubMed

    Maaß, Christian; Rivas, Jose Ricardo Avelar; Attarwala, Ali Asgar; Hardiansyah, Deni; Niedermoser, Sabrina; Litau, Shanna; Wängler, Carmen; Wängler, Björn; Glatting, Gerhard

    2016-04-01

    Peptide receptor radionuclide therapy (PRRT) is commonly performed in the treatment of neuroendocrine tumors (NET), where somatostatin analogs (DOTATATE) are radiolabeled with (90)Y, (68)Ga or (111)In for pre-therapeutic and therapeutic purposes. Quantitative evaluation of the biokinetic data can be performed by using physiologically based pharmacokinetic (PBPK) models. Knowledge about the biodistribution in a pre-clinical setting would allow optimizing the translation from bench to bedside. The aim of this study was to develop a PBPK model to describe the biodistribution of a novel sst2-targeting radiotracer. Biokinetic data of six mice after injection of (18)F-SiFAlin-Asp3-PEG1-TATE were investigated using two PBPK models. The PBPK models describe the biodistribution of the tracer in the tumor, kidneys, liver, remainder and whole body via blood flow to these organs via absorption, distribution, metabolism and excretion. A recently published sst2 PBPK model for humans (model 1) was used to describe the data. Physiological information in this model was adapted to that of a mouse. Model 1 was further modified by implementing receptor-mediated endocytosis (model 2). Model parameters were fitted to the biokinetic data of each mouse. Model selection was performed by calculating Akaike weights wi using the corrected Akaike Information Criterion (AICc). The implementation of receptor-mediated endocytosis considerably improved the description of the biodistribution (Akaike weights w1=0% and w2=100% for model 1 and 2, respectively). The resulting time-integrated activity coefficients determined by model 2 were for tumor (0.05 ± 0.02) h, kidneys (0.11 ± 0.01) h and liver (0.02 ± 0.01) h. Simply downscaling a human PBPK model does not allow for an accurate description of (18)F-SiFAlin-Asp3-PEG1-TATE in mice. Biokinetics of this tracer can be accurately and adequately described using a physiologically based pharmacokinetic model including receptor-mediated endocytosis. Thus, an optimized translation from bench to bedside is possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Hybrid radioguided occult lesion localization (hybrid ROLL) of (18)F-FDG-avid lesions using the hybrid tracer indocyanine green-(99m)Tc-nanocolloid.

    PubMed

    KleinJan, G H; Brouwer, O R; Mathéron, H M; Rietbergen, D D D; Valdés Olmos, R A; Wouters, M W; van den Berg, N S; van Leeuwen, F W B

    2016-01-01

    To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable (18)F-FDG-avid lesions on PET/CT. Four patients with (18)F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. A total of six (18)F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  1. Comparison of (/sup 14/C)glucose and (/sup 14/C)deoxyglucose as tracers of brain glucose use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, R.A.; Mans, A.M.; Davis, D.W.

    1988-03-01

    Because glucose metabolism and functional activity in brain regions are normally coupled, knowledge of regional brain glucose use can yield insights into regional functional activity. The deoxyglucose (DG) method is widely used for this purpose in experimental animals and humans but questions have arisen regarding its limits and accuracy. Therefore an experiment was designed to compare the DG method on a structure-by-structure basis with another tracer of glucose use, (6-/sup 14/C)glucose, in normal rats. The cerebral metabolic rates obtained using the two tracers were similar in the telencephalon, but the results using DG were substantially lower in the midbrain andmore » hindbrain (diencephalon, 18%; mesencephalon, 20%; metencephalon, 29%; and myelencephalon, 35%). The primary DG metabolite, DG 6-phosphate (DG-6-P) was found to disappear in a non-uniform manner from the major brain structures: telencephalon less than diencephalon less than mesencephalon = metencephalon less than myelencephalon. Thus a correlation was found between the rate of DG-6-P loss and the extent to which the DG method gave lower values of glucose use. Thus this may explain, at least in part, the discrepancies between the two methods.« less

  2. In-vivo measurements of regional acetylcholine esterase activity in degenerative dementia: comparison with blood flow and glucose metabolism.

    PubMed

    Herholz, K; Bauer, B; Wienhard, K; Kracht, L; Mielke, R; Lenz, M O; Strotmann, T; Heiss, W D

    2000-01-01

    Memory and attention are cognitive functions that depend heavily on the cholinergic system. Local activity of acetylcholine esterase (AChE) is an indicator of its integrity. Using a recently developed tracer for positron emission tomography (PET), C-11-labeled N-methyl-4-piperidyl-acetate (C11-MP4A), we measured regional AChE activity in 4 non-demented subjects, 4 patients with dementia of Alzheimer type (DAT) and 1 patient with senile dementia of Lewy body type (SDLT), and compared the findings with measurements of blood flow (CBF) and glucose metabolism (CMRGlc). Initial tracer extraction was closely related to CBF. AChE activity was reduced significantly in all brain regions in demented subjects, whereas reduction of CMRGlc and CBF was more limited to temporo-parietal association areas. AChE activity in SDLT was in the lower range of values in DAT. Our results indicate that, compared to non-demented controls, there is a global reduction of cortical AChE activity in dementia. Dementia, cholinergic system, acetylcholine esterase, positron emission tomography, cerebral blood flow, cerebral glucose metabolism.

  3. Optimization of a large-scale microseismic monitoring network in northern Switzerland

    NASA Astrophysics Data System (ADS)

    Kraft, Toni; Mignan, Arnaud; Giardini, Domenico

    2013-10-01

    We have developed a network optimization method for regional-scale microseismic monitoring networks and applied it to optimize the densification of the existing seismic network in northeastern Switzerland. The new network will build the backbone of a 10-yr study on the neotectonic activity of this area that will help to better constrain the seismic hazard imposed on nuclear power plants and waste repository sites. This task defined the requirements regarding location precision (0.5 km in epicentre and 2 km in source depth) and detection capability [magnitude of completeness Mc = 1.0 (ML)]. The goal of the optimization was to find the geometry and size of the network that met these requirements. Existing stations in Switzerland, Germany and Austria were considered in the optimization procedure. We based the optimization on the simulated annealing approach proposed by Hardt & Scherbaum, which aims to minimize the volume of the error ellipsoid of the linearized earthquake location problem (D-criterion). We have extended their algorithm to: calculate traveltimes of seismic body waves using a finite difference ray tracer and the 3-D velocity model of Switzerland, calculate seismic body-wave amplitudes at arbitrary stations assuming the Brune source model and using scaling and attenuation relations recently derived for Switzerland, and estimate the noise level at arbitrary locations within Switzerland using a first-order ambient seismic noise model based on 14 land-use classes defined by the EU-project CORINE and open GIS data. We calculated optimized geometries for networks with 10-35 added stations and tested the stability of the optimization result by repeated runs with changing initial conditions. Further, we estimated the attainable magnitude of completeness (Mc) for the different sized optimal networks using the Bayesian Magnitude of Completeness (BMC) method introduced by Mignan et al. The algorithm developed in this study is also applicable to smaller optimization problems, for example, small local monitoring networks. Possible applications are volcano monitoring, the surveillance of induced seismicity associated with geotechnical operations and many more. Our algorithm is especially useful to optimize networks in populated areas with heterogeneous noise conditions and if complex velocity structures or existing stations have to be considered.

  4. Digital microfluidics – a new paradigm for radiochemistry

    PubMed Central

    Keng, Pei Yuin; van Dam, R. Michael

    2016-01-01

    The emerging technology of digital microfluidics is opening up the possibility to perform radiochemistry at the microliter scale to produce tracers for positron emission tomography (PET) labeled with fluorine-18 or other isotopes. Working at this volume scale not only reduces reagent costs, but also improves specific activity (SA) by reduction of contamination by the stable isotope. This technology could provide a practical means to routinely prepare high SA tracers for applications such as neuroimaging, and could make it possible to routinely achieve high SA using synthesis strategies such as isotopic exchange. Reagent droplets are controlled electronically, providing high reliability, a compact control system, and flexibility for diverse syntheses with a single chip design. The compact size may enable the development of a self-shielded synthesizer that does not require a hot cell. This article reviews the progress of this technology and its application to the synthesis of PET tracers. PMID:26650206

  5. 11C-meta-hydroxyephedrine PET/CT imaging allows in vivo study of adaptive thermogenesis and white-to-brown fat conversion

    PubMed Central

    Quarta, Carmelo; Lodi, Filippo; Mazza, Roberta; Giannone, Ferdinando; Boschi, Laura; Nanni, Cristina; Nisoli, Enzo; Boschi, Stefano; Pasquali, Renato; Fanti, Stefano; Iozzo, Patricia; Pagotto, Uberto

    2013-01-01

    Several lines of evidence suggest that novel pharmacological approaches aimed at converting white adipose tissue (WAT) into brown adipose tissue (BAT) may represent an effective therapeutic strategy for obesity and related disorders. (18)F-fluorodeoxyglucose (18F-FDG) is the only positron emission tomography (PET) tracer commonly used to study BAT function, and so far no functional tools have been described to investigate in vivo white-to-brown fat conversion. In this report, we show that the PET tracer 11C-meta-hydroxyephedrine (11C-MHED, a norepinephrine analogue) is a useful tool to investigate the sympathetic nervous system (SNS) activity in BAT of lean and dietary obese mice. Moreover, we demonstrate that 11C-MHED is a specific marker of the SNS-mediated thermogenesis in typical BAT depots, and that this tracer can detect in vivo WAT to BAT conversion. PMID:24049730

  6. The method of radioactive tracer for measuring the amount of inorganic nanoparticles in biological samples

    NASA Astrophysics Data System (ADS)

    Buzulukov, Yu; Antsiferova, A.; Demin, V. A.; Demin, V. F.; Kashkarov, P.

    2015-11-01

    The method to measure the mass of inorganic nanoparticles in biological (or any other samples) using nanoparticles labeled with radioactive tracers is developed and applied to practice. The tracers are produced in original nanoparticles by radioactive activation of some of their atomic nuclei. The method of radioactive tracers demonstrates a sensitivity, specificity and accuracy equal or better than popular methods of optical and mass spectrometry, or electron microscopy and has some specific advantages. The method can be used for study of absorption, distribution, metabolism and excretion in living organism, as well as in ecological and fundamental research. It was used in practice to study absorption, distribution, metabolism and excretion of nanoparticles of Ag, Au, Se, ZnO, TiO2 as well as to study transportation of silver nanoparticles through the barriers of blood-brain, placenta and milk gland of rats. Brief descriptions of data obtained in experiments with application of this method included in the article. The method was certified in Russian Federation standard system GOST-R and recommended by the Russian Federation regulation authority ROSPOTREBNADZOR for measuring of toxicokinetic and organotropy parameters of nanoparticles.

  7. Linkage between Researchers and Practitioners: A Qualitative Study.

    ERIC Educational Resources Information Center

    Huberman, Michael

    1990-01-01

    A multiple-case, "tracer" study was undertaken involving 11 research projects of the "Education et Vie Active" (Education and the Active Life)--a national vocational education program in Switzerland--to assess the importance of contacts between researchers and practitioners. Iterative data from interviews, observations, and…

  8. Journal: A Review of Some Tracer-Test Design Equations for Tracer-Mass Estimation and Sample Collection Frequency

    EPA Science Inventory

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estima...

  9. Bioirrigation impacts on sediment respiration and microbial metabolic activity

    NASA Astrophysics Data System (ADS)

    Baranov, V. A.; Lewandowski, J.; Romeijn, P.; Krause, S.

    2015-12-01

    Some bioturbators build tubes in the sediment and pump water through their burrows (ventilation). Oxygen is transferred through the burrow walls in the adjacent sediment (bioirrigation). Bioirrigation is playing a pivotal role in the mediation of biogeochemical processes in lake sediments and has the potential to enhance nutrient cycling. The present study investigates the impact of bioirrigation on lake sediment metabolism, respiration rates and in particular, the biogeochemical impacts of bioirrigation intensity as a function of organism density. We therefore apply the bioreactive Resazurin/Resorufin smart tracer system for quantifying the impact of different densities of Chironomidae (Diptera) larvae (0-2112 larvae/m2) on lake sediment respiration in a microcosm experiment. Tracer decay has been found to be proportional to the amount of the aerobic respiration at the sediment-water interface. Tracer transformation was in good agreement with Chironomidae density (correlation, r=0.9). Tracer transformation rates (and sediment respiration) were found to be correlated to Chironomidae density, with highest transformation rates observed in the microcosms with highest density of 2112 larvae/m2. This relationship was not linear though, with sediment respiration rates at the highest larvae densities declining from the linear trend predicted from lower and intermediate larvae density-respiration relationships. We interpret this effect as a density dependent suppression of the Chironomid's metabolic activity. The observations of this study have implications for eutrophied lakes with high densities of bioirrigators. Despite high density of bioirrigirrigating benthos, mineralization of the organic matter in such habitats would likely be lower than in lakes with intermediate densities of the bioturbators.

  10. Wear Measurement of Highly Cross-Linked UHMWPE Using a 7Be Tracer Implantation Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimmer, Markus; Laurent, Michael P.; Dwivedi, Yash

    2013-01-29

    The very low wear rates achieved with the current highly cross-linked ultra-high molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are therefore being explored. The purpose of this study was to effect a proof-of-concept on the use of the radioactive tracer beryllium-7 (7Be) for the determination of wear in a highly cross-linked orthopedic UHMWPE. Three crosslinked and four conventional UHMWPE pins made from compression-molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei upmore » to 8.5 μm below the surface. The pins were tested for wear in a six-station pin-on-flat apparatus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and estimated to be 17 ± 3 μg/Mc. The conventional-to-cross-linked ratio of the wear rates was 13.1 ± 0.8, in the expected range for these materials. It was estimated that implantation reduced the average wear rate by approximately 20%, and the oxidative degradation damage from implantation was negligible. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.« less

  11. Morphometric Analysis of Aqueous Humor Outflow Structures with Spectral-Domain Optical Coherence Tomography

    PubMed Central

    Francis, Andrew W.; Kagemann, Larry; Wollstein, Gadi; Ishikawa, Hiroshi; Folz, Steven; Overby, Darryl R.; Sigal, Ian A.; Wang, Bo; Schuman, Joel S.

    2012-01-01

    Purpose. To describe morphometric details of the human aqueous humor (AH) outflow microvasculature visualized with 360-degree virtual castings during active AH outflow in cadaver eyes and to compare these structures with corrosion casting studies. Methods. The conventional AH outflow pathways of donor eyes (n = 7) and eyes in vivo (n = 3) were imaged with spectral-domain optical coherence tomography (SD-OCT) and wide-bandwidth superluminescent diode array during active AH outflow. Digital image contrast was adjusted to isolate AH microvasculature, and images were viewed in a 3D viewer. Additional eyes (n = 3) were perfused with mock AH containing fluorescent tracer microspheres to compare microvasculature patterns. Results. Observations revealed components of the conventional outflow pathway from Schlemm's canal (SC) to the superficial intrascleral venous plexus (ISVP). The superficial ISVP in both our study and corrosion casts were composed of interconnected venules (10–50 μm) forming a hexagonal meshwork. Larger radial arcades (50–100 μm) drained the region nearest SC and converged with larger tortuous vessels (>100 μm). A 360-degree virtual casting closely approximated corrosion casting studies. Tracer studies corroborated our findings. Tracer decorated several larger vessels (50–100 μm) extending posteriorly from the limbus in both raw and contrast-enhanced fluorescence images. Smaller tracer-labeled vessels (30–40 μm) were seen branching between larger vessels and exhibited a similar hexagonal network pattern. Conclusions. SD-OCT is capable of detailed morphometric analysis of the conventional outflow pathway in vivo or ex vivo with details comparable to corrosion casting techniques. PMID:22499987

  12. The escape problem for mortal walkers

    NASA Astrophysics Data System (ADS)

    Grebenkov, D. S.; Rupprecht, J.-F.

    2017-02-01

    We introduce and investigate the escape problem for random walkers that may eventually die, decay, bleach, or lose activity during their diffusion towards an escape or reactive region on the boundary of a confining domain. In the case of a first-order kinetics (i.e., exponentially distributed lifetimes), we study the effect of the associated death rate onto the survival probability, the exit probability, and the mean first passage time. We derive the upper and lower bounds and some approximations for these quantities. We reveal three asymptotic regimes of small, intermediate, and large death rates. General estimates and asymptotics are compared to several explicit solutions for simple domains and to numerical simulations. These results allow one to account for stochastic photobleaching of fluorescent tracers in bio-imaging, degradation of mRNA molecules in genetic translation mechanisms, or high mortality rates of spermatozoa in the fertilization process. Our findings provide a mathematical ground for optimizing storage containers and materials to reduce the risk of leakage of dangerous chemicals or nuclear wastes.

  13. Comparative modeling of an in situ diffusion experiment in granite at the Grimsel Test Site.

    PubMed

    Soler, Josep M; Landa, Jiri; Havlova, Vaclava; Tachi, Yukio; Ebina, Takanori; Sardini, Paul; Siitari-Kauppi, Marja; Eikenberg, Jost; Martin, Andrew J

    2015-08-01

    An in situ diffusion experiment was performed at the Grimsel Test Site (Switzerland). Several tracers ((3)H as HTO, (22)Na(+), (134)Cs(+), (131)I(-) with stable I(-) as carrier) were continuously circulated through a packed-off borehole and the decrease in tracer concentrations in the liquid phase was monitored for a period of about 2years. Subsequently, the borehole section was overcored and the tracer profiles in the rock analyzed ((3)H, (22)Na(+), (134)Cs(+)). (3)H and (22)Na(+) showed a similar decrease in activity in the circulation system (slightly larger drop for (3)H). The drop in activity for (134)Cs(+) was much more pronounced. Transport distances in the rock were about 20cm for (3)H, 10cm for (22)Na(+), and 1cm for (134)Cs(+). The dataset (except for (131)I(-) because of complete decay at the end of the experiment) was analyzed with different diffusion-sorption models by different teams (IDAEA-CSIC, UJV-Rez, JAEA) using different codes, with the goal of obtaining effective diffusion coefficients (De) and porosity (ϕ) or rock capacity (α) values. From the activity measurements in the rock, it was observed that it was not possible to recover the full tracer activity in the rock (no activity balance when adding the activities in the rock and in the fluid circulation system). A Borehole Disturbed Zone (BDZ) had to be taken into account to fit the experimental observations. The extension of the BDZ (1-2mm) is about the same magnitude than the mean grain size of the quartz and feldspar grains. IDAEA-CSIC and UJV-Rez tried directly to match the results of the in situ experiment, without forcing any laboratory-based parameter values into the models. JAEA conducted a predictive modeling based on laboratory diffusion data and their scaling to in situ conditions. The results from the different codes have been compared, also with results from small-scale laboratory experiments. Outstanding issues to be resolved are the need for a very large capacity factor in the BDZ for (3)H and the difference between apparent diffusion coefficients (Da) from the in situ experiment and out-leaching laboratory tests. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Randomized, single-blind, factorial design study of the interaction of food and time on intestinal activity in 99mTc-tetrofosmin stress myocardial perfusion scintigraphy.

    PubMed

    Lyngholm, Ann Marie; Pedersen, Begitte H; Petersen, Lars J

    2008-09-01

    Intestinal activity at the inferior myocardial wall represents an issue for assessment of myocardial perfusion imaging (MPI) with 99mTc-labelled tracers. The aim of this study was to investigate the effect of time and food on upper abdominal activity in 99mTc-tetrofosmin MPI. The study population consisted of 152 consecutive patients referred for routine MPI. All patients underwent 2-day stress-rest 99mTc-tetrofosmin single-photon emission computed tomography MPI. Before stress testing, patients were randomized in a factorial design to four different regimens. Group A: early scan (image acquisition initiated within 15 min after injection of the tracer) and no food; group B: early scan and food (two pieces of white bread with butter and a minimum of 450 ml of water); group C: late scan (image acquisition 30-60 min after injection of the tracer) and no food; and group D: late and scan with food. Patients underwent standard bicycle exercise or pharmacological stress test. The degree of upper abdominal activity was evaluated by trained observers blinded to the randomization code. The primary endpoint was the proportion of accepted scans in the intention-to-treat population in stress MPI. The results showed statistical significant impact on both time and food on upper abdominal activity. The primary endpoint showed that the acceptance rate improved from 55% in group A to 100% success rate in group D. An early scan reduced the acceptance rate by 30% versus a late scan [hazard ratio 0.70, 95% confidence interval 0.58-0.84; P<0.0001], whereas the addition of food improved the success rate versus no food by 27% (hazard ratio 1.27, 95% confidence interval 1.07-1.51; P=0.006). No significant interaction between food and time was observed. An analysis of accepted scans according to the actual scan time and food consumption confirmed the findings of the intention-to-treat analysis. In addition, similar findings were seen in 116 of 152 patients with a rest MPI (success rate of 53% in group A vs. 96% in group D). A combination of solid food and water administered after injection of the tracer and delayed image acquisition led to significant and clinically relevant decrease of interfering upper abdominal activity in 99mTc-tetrofosmin MPI.

  15. Influence of radioactivity out of the field of view on 3D PET dynamic measurement with [/sup 11/C]MP4A

    NASA Astrophysics Data System (ADS)

    Hasegawa, T.; Suzuki, M.; Murayama, H.; Irie, T.; Fukushi, K.; Wada, Y.

    1999-08-01

    This study assessed the influence of radioactivity out of the field of view (out-of-FOV) on the measurement of brain acetylcholinesterase (AChE) activity with the tracer [/sup 11/C]N-methyl-4-piperidyl-acetate by positron emission tomography in three-dimensional mode. Dynamic scans on a volunteer showed that the out-of-FOV radioactivity in the chest was much higher than that of the brain immediately after tracer injection. A representative phantom measurement was performed to quantitate the systematic errors due to the out-of-FOV radioactivity. Resultant errors in the AChE activity (k3 parameter) as calculated by compartment model analysis were found to be less than one percent in all of the brain regions studied.

  16. Cost efficient environmental survey paths for detecting continuous tracer discharges

    NASA Astrophysics Data System (ADS)

    Alendal, G.

    2017-07-01

    Designing monitoring programs for detecting potential tracer discharges from unknown locations is challenging. The high variability of the environment may camouflage the anticipated anisotropic signal from a discharge, and there are a number of discharge scenarios. Monitoring operations may also be costly, constraining the number of measurements taken. By assuming that a discharge is active, and a prior belief on the most likely seep location, a method that uses Bayes' theorem combined with discharge footprint predictions is used to update the probability map. Measurement locations with highest reduction in the overall probability of a discharge to be active can be identified. The relative cost between reallocating and measurements can be taken into account. Three different strategies are suggested to enable cost efficient paths for autonomous vessels.

  17. Hydrological tracers using nanobiotechnology: proof of concept.

    PubMed

    Sharma, Asha N; Luo, Dan; Walter, M Todd

    2012-08-21

    In order to answer questions that involve differentiating among multiple and potentially interacting hydrological flowpaths, it would be ideal to use multiple tracers with identical transport properties that can nonetheless be distinguished from each other. This paper describes the development and proof of concept of a new kind of engineered tracer system that allows a large number of individual tracers to be simultaneously distinguished from one another. This new tracer is composed of polylactic acid (PLA) microspheres into which short strands of synthetic DNA and paramagnetic iron oxide nanoparticles are incorporated. The synthetic DNA serves as the "label" or "tag" in our tracers that allow us to distinguish one tracer from another, and paramagnetic iron oxide nanoparticles are included in the tracer to facilitate magnetic concentration of the tracers in potentially dilute water samples. Some potential advantages of this tracer concept include: virtually limitless uniquely labeled tracers, highly sensitive detection, and relatively moderate expense. Three proof-of-concept experiments at scales ranging from orders of 10 cm to 100 m demonstrated the use of the tracer system.

  18. Preclinical Kinetic Analysis of the Caspase-3/7 PET Tracer 18F-C-SNAT: Quantifying the Changes in Blood Flow and Tumor Retention After Chemotherapy.

    PubMed

    Palner, Mikael; Shen, Bin; Jeon, Jongho; Lin, Jianguo; Chin, Frederick T; Rao, Jianghong

    2015-09-01

    Early detection of tumor response to therapy is crucial to the timely identification of the most efficacious treatments. We recently developed a novel apoptosis imaging tracer, (18)F-C-SNAT (C-SNAT is caspase-sensitive nanoaggregation tracer), that undergoes an intramolecular cyclization reaction after cleavage by caspase-3/7, a biomarker of apoptosis. This caspase-3/7-dependent reaction leads to an enhanced accumulation and retention of (18)F activity in apoptotic tumors. This study aimed to fully examine in vivo pharmacokinetics of the tracer through PET imaging and kinetic modeling in a preclinical mouse model of tumor response to systemic anticancer chemotherapy. Tumor-bearing nude mice were treated 3 times with intravenous injections of doxorubicin before undergoing a 120-min dynamic (18)F-C-SNAT PET/CT scan. Time-activity curves were extracted from the tumor and selected organs. A 2-tissue-compartment model was fitted to the time-activity curves from tumor and muscle, using the left ventricle of the heart as input function, and the pharmacokinetic rate constants were calculated. Both tumor uptake (percentage injected dose per gram) and the tumor-to-muscle activity ratio were significantly higher in the treated mice than untreated mice. Pharmacokinetic rate constants calculated by the 2-tissue-compartment model showed a significant increase in delivery and accumulation of the tracer after the systemic chemotherapeutic treatment. Delivery of (18)F-C-SNAT to the tumor tissue, quantified as K1, increased from 0.31 g⋅(mL⋅min)(-1) in untreated mice to 1.03 g⋅(mL⋅min)(-1) in treated mice, a measurement closely related to changes in blood flow. Accumulation of (18)F-C-SNAT, quantified as k3, increased from 0.03 to 0.12 min(-1), proving a higher retention of (18)F-C-SNAT in treated tumors independent from changes in blood flow. An increase in delivery was also found in the muscular tissue of treated mice without increasing accumulation. (18)F-C-SNAT has significantly increased tumor uptake and significantly increased tumor-to-muscle ratio in a preclinical mouse model of tumor therapy. Furthermore, our kinetic modeling of (18)F-C-SNAT shows that chemotherapeutic treatment increased accumulation (k3) in the treated tumors, independent of increased delivery (K1). © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  19. Project Physics Handbook 6, The Nucleus.

    ERIC Educational Resources Information Center

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Five experiments and nine activities are presented in this Unit 6 handbook. The experiments are related to random events, ranges of alpha and beta particles, half-lives, and radioactive tracers. The activities are concerned with the energy measurement in beta radiation, demonstration with sugar cubes, ionization by radioactivity, magnetic…

  20. Can 239 + 240Pu replace 137Cs as an erosion tracer in agricultural landscapes contaminated with Chernobyl fallout?

    PubMed

    Schimmack, W; Auerswald, K; Bunzl, K

    2001-01-01

    Erosion studies often use 137Cs from the global fallout (main period: 1953-1964) as a tracer in the soil. In many European countries, where 137Cs was deposited in considerable amounts also by the Chernobyl fallout in 1986, the global fallout fraction (GF-Cs) has to be separated from the Chernobyl fraction by means of the isotope 134Cs. In a few years, this will no longer be possible due to the short half-life of 134Cs (2 yr). Because GF-Cs in the soil can then no longer be determined, the potential of using 239 + 240Pu as a tracer is evaluated. This radionuclide originates in most European countries essentially only from the global fallout. The activities and spatial distributions of Pu and GF-Cs were compared in the soil of a steep field (inclination about 20%, area ca. 3 ha, main soil type Dystric Eutrochrept), sampled at 48 nodes of a 25 x 25 m2 grid. The reference values were determined at 12 points adjacent to the field. Their validity was assured by an inventory study of radiocaesium in a 70 ha area surrounding the field sampling 275 nodes of a 50 x 50 m2 grid. In the field studied, the activity concentrations of GF-Cs and Pu in the Ap horizon were not correlated (Spearman correlation coefficient R = 0.20, p > 0.05), and the activity balance of Pu differed from that of GF-Cs. Whereas no net loss of GF-Cs from the field was observed as compared to the reference site, Pu was more mobile with an average loss of ca. 11% per unit area. In addition, the spatial pattern of GF-Cs and Pu in the field differed significantly. The reason may be that due to their different associations with soil constituents, Pu and Cs represent different fractions of the soil, exhibiting different properties with respect to erosion/deposition processes. This indicates that both radionuclides or one of them may not be appropriate to quantity past erosion. When tracer losses are used to calibrate or verify erosion prediction models, systematic deviations may not only stem from model shortcomings but also from tracer technique.

  1. Environmental monitoring of El Hierro Island submarine volcano, by combining low and high resolution satellite imagery

    NASA Astrophysics Data System (ADS)

    Eugenio, F.; Martin, J.; Marcello, J.; Fraile-Nuez, E.

    2014-06-01

    El Hierro Island, located at the Canary Islands Archipelago in the Atlantic coast of North Africa, has been rocked by thousands of tremors and earthquakes since July 2011. Finally, an underwater volcanic eruption started 300 m below sea level on October 10, 2011. Since then, regular multidisciplinary monitoring has been carried out in order to quantify the environmental impacts caused by the submarine eruption. Thanks to this natural tracer release, multisensorial satellite imagery obtained from MODIS and MERIS sensors have been processed to monitor the volcano activity and to provide information on the concentration of biological, chemical and physical marine parameters. Specifically, low resolution satellite estimations of optimal diffuse attenuation coefficient (Kd) and chlorophyll-a (Chl-a) concentration under these abnormal conditions have been assessed. These remote sensing data have played a fundamental role during field campaigns guiding the oceanographic vessel to the appropriate sampling areas. In addition, to analyze El Hierro submarine volcano area, WorldView-2 high resolution satellite spectral bands were atmospherically and deglinted processed prior to obtain a high-resolution optimal diffuse attenuation coefficient model. This novel algorithm was developed using a matchup data set with MERIS and MODIS data, in situ transmittances measurements and a seawater radiative transfer model. Multisensor and multitemporal imagery processed from satellite remote sensing sensors have demonstrated to be a powerful tool for monitoring the submarine volcanic activities, such as discolored seawater, floating material and volcanic plume, having shown the capabilities to improve the understanding of submarine volcanic processes.

  2. Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

    PubMed

    Liu, Dan; Khong, Pek-Lan; Gao, Yiming; Mahmood, Usman; Quinn, Brian; St Germain, Jean; Xu, X George; Dauer, Lawrence T

    2016-06-01

    Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. Consecutive adult patients with hepatocellular carcinoma who underwent whole-body dual-tracer PET/CT scans were retrospectively reviewed with institutional review board approval. OLINDA/EXM 1.1 was used to estimate patient-specific internal dose exposure in each organ. Biokinetic models for (18)F-FDG and (11)C-acetate as provided by ICRP (International Commission on Radiological Protection) publication 106 were used. Standard reference phantoms were modified to more closely represent patient-specific organ mass. With patient-specific parameters, organ equivalent doses from each CT series were estimated using VirtualDose. Dosimetry capabilities for tube current modulation protocols were applied by integrating with the latest anatomic realistic models. Effective dose was calculated using ICRP publication 103 tissue-weighting coefficients for adult male and female, respectively. Fourteen scans were evaluated (12 men, 2 women; mean age ± SD, 60 ± 19.48 y). The patient-specific effective dose from (18)F-FDG and (11)C-acetate was 6.08 ± 1.49 and 1.56 ± 0.47 mSv, respectively, for male patients and 6.62 ± 1.38 and 1.79 ± 0.12 mSV, respectively, for female patients. The patient-specific effective dose of the CT component, which comprised 2 noncontrast whole-body scans, to male and female patients was 21.20 ± 8.94 and 14.79 ± 3.35 mSv, respectively. Thus, the total effective doses of the combined whole-body dual-tracer PET/CT studies for male and female patients were 28.84 ± 10.18 and 23.19 ± 4.61 mSv, respectively. Patient-specific parameters allow for more accurate estimation of organ equivalent doses. Considering the substantial radiation dose incurred, judicious medical justification is required with every whole-body dual-tracer PET/CT referral. Although radiation risks may have less impact for the population with cancer because of their reduced life expectancy, the information is of interest and relevant for both justification, to evaluate risk/benefit, and protocol optimization. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. ELIXYS - a fully automated, three-reactor high-pressure radiosynthesizer for development and routine production of diverse PET tracers

    PubMed Central

    2013-01-01

    Background Automated radiosynthesizers are vital for routine production of positron-emission tomography tracers to minimize radiation exposure to operators and to ensure reproducible synthesis yields. The recent trend in the synthesizer industry towards the use of disposable kits aims to simplify setup and operation for the user, but often introduces several limitations related to temperature and chemical compatibility, thus requiring reoptimization of protocols developed on non-cassette-based systems. Radiochemists would benefit from a single hybrid system that provides tremendous flexibility for development and optimization of reaction conditions while also providing a pathway to simple, cassette-based production of diverse tracers. Methods We have designed, built, and tested an automated three-reactor radiosynthesizer (ELIXYS) to provide a flexible radiosynthesis platform suitable for both tracer development and routine production. The synthesizer is capable of performing high-pressure and high-temperature reactions by eliminating permanent tubing and valve connections to the reaction vessel. Each of the three movable reactors can seal against different locations on disposable cassettes to carry out different functions such as sealed reactions, evaporations, and reagent addition. A reagent and gas handling robot moves sealed reagent vials from storage locations in the cassette to addition positions and also dynamically provides vacuum and inert gas to ports on the cassette. The software integrates these automated features into chemistry unit operations (e.g., React, Evaporate, Add) to intuitively create synthesis protocols. 2-Deoxy-2-[18F]fluoro-5-methyl-β-l-arabinofuranosyluracil (l-[18F]FMAU) and 2-deoxy-2-[18F]fluoro-β-d-arabinofuranosylcytosine (d-[18F]FAC) were synthesized to validate the system. Results l-[18F]FMAU and d-[18F]FAC were successfully synthesized in 165 and 170 min, respectively, with decay-corrected radiochemical yields of 46% ± 1% (n = 6) and 31% ± 5% (n = 6), respectively. The yield, repeatability, and synthesis time are comparable to, or better than, other reports. d-[18F]FAC produced by ELIXYS and another manually operated apparatus exhibited similar biodistribution in wild-type mice. Conclusion The ELIXYS automated radiosynthesizer is capable of performing radiosyntheses requiring demanding conditions: up to three reaction vessels, high temperatures, high pressures, and sensitive reagents. Such flexibility facilitates tracer development and the ability to synthesize multiple tracers on the same system without customization or replumbing. The disposable cassette approach simplifies the transition from development to production. PMID:23849185

  4. Tritium as tracer of groundwater pollution extension: case study of Andralanitra landfill site, Antananarivo-Madagascar

    NASA Astrophysics Data System (ADS)

    Ramaroson, Voahirana; Rakotomalala, Christian Ulrich; Rajaobelison, Joel; Fareze, Lahimamy Paul; Razafitsalama, Falintsoa A.; Rasolofonirina, Mamiseheno

    2018-05-01

    This study aims to understand the extension of groundwater pollution downstream of a landfill, Andralanitra-Antananarivo-Madagascar. Twenty-one samples, composed of dug well waters, spring waters, river, and lake, were measured in stable isotopes ( δ 2H, δ 18O) and tritium. Results showed that only two dug well waters, collected at the immediate vicinity of the landfill, have high tritium activities (22.82 TU and 10.43 TU), probably of artificial origin. Both upstream and further downstream of the landfill, tritium activities represent natural source, with values varying from 0.17 TU to 1.46 TU upstream and from 0.88 TU to 1.88 TU further downstream. Stable isotope data suggest that recharge occurs through infiltration of slightly evaporated rainfall. Using the radioactive decay equation, the calculated tracer ages related to two recent ground water samples collected down gradient of the landfill lay between [8-15] years and [4-7] years, taking into account the uncertainty of tritium measurements. For the calculation, a value of 2.36 TU was taken as A o. The latter was estimated based on similarity between stable isotope compositions of nearby spring and dug well waters as well as tritium activities of the local precipitation. Calculation of the tritium activities from the contaminated water point having 22.82 TU to further downstream using the calculated tracer ages showed values of one order of magnitude higher than the measured values. The absence of hydrological connection from the contaminated water point to further downstream the landfill would explain the lower tritium activities measured. Groundwater pollution seems to be limited to the closest proximity of the landfill.

  5. [18F]-FDG positron emission tomography--an established clinical tool opening a new window into exercise physiology.

    PubMed

    Rudroff, Thorsten; Kindred, John H; Kalliokoski, Kari K

    2015-05-15

    Positron emission tomography (PET) with [(18)F]-fluorodeoxyglucose (FDG) is an established clinical tool primarily used to diagnose and evaluate disease status in patients with cancer. PET imaging using FDG can be a highly valuable tool to investigate normal human physiology by providing a noninvasive, quantitative measure of glucose uptake into various cell types. Over the past years it has also been increasingly used in exercise physiology studies to identify changes in glucose uptake, metabolism, and muscle activity during different exercise modalities. Metabolically active cells transport FDG, an (18)fluorine-labeled glucose analog tracer, from the blood into the cells where it is then phosphorylated but not further metabolized. This metabolic trapping process forms the basis of this method's use during exercise. The tracer is given to a participant during an exercise task, and the actual PET imaging is performed immediately after the exercise. Provided the uptake period is of sufficient duration, and the imaging is performed shortly after the exercise; the captured image strongly reflects the metabolic activity of the cells used during the task. When combined with repeated blood sampling to determine tracer blood concentration over time, also known as the input function, glucose uptake rate of the tissues can be quantitatively calculated. This synthesis provides an accounting of studies using FDG-PET to measure acute exercise-induced skeletal muscle activity, describes the advantages and limitations of this imaging technique, and discusses its applications to the field of exercise physiology. Copyright © 2015 the American Physiological Society.

  6. Innovative techniques for the description of reservoir heterogeneity using tracers. Second technical annual progress report, October 1991--September 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Sepehrnoori, K.

    1992-12-31

    This second annual report on innovative uses of tracers for reservoir characterization contains four sections each describing a novel use of oilfield tracers. The first section describes and illustrates the use of a new single-well tracer test to estimate wettability. This test consists of the injection of brine containing tracers followed by oil containing tracers, a shut-in period to allow some of the tracers to react, and then production of the tracers. The inclusion of the oil injection slug with tracers is unique to this test, and this is what makes the test work. We adapted our chemical simulator, UTCHEM,more » to enable us to study this tracer method and made an extensive simulation study to evaluate the effects of wettability based upon characteristic curves for relative permeability and capillary pressure for differing wetting states typical of oil reservoirs. The second section of this report describes a new method for analyzing interwell tracer data based upon a type-curve approach. Theoretical frequency response functions were used to build type curves of ``transfer function`` and ``phase spectrum`` that have dimensionless heterogeneity index as a parameter to characterize a stochastic permeability field. We illustrate this method by analyzing field tracer data. The third section of this report describes a new theory for interpreting interwell tracer data in terms of channeling and dispersive behavior for reservoirs. Once again, a stochastic approach to reservoir description is taken. The fourth section of this report describes our simulation of perfluorocarbon gas tracers. This new tracer technology developed at Brookhaven National Laboratory is being tested at the Elk Hills Naval Petroleum Reserve No. 1 in California. We report preliminary simulations made of these tracers in one of the oil reservoirs under evaluation with these tracers in this field. Our compostional simulator (UTCOMP) was used for this simulation study.« less

  7. Benchmark Results Of Active Tracer Particles In The Open Souce Code ASPECT For Modelling Convection In The Earth's Mantle

    NASA Astrophysics Data System (ADS)

    Jiang, J.; Kaloti, A. P.; Levinson, H. R.; Nguyen, N.; Puckett, E. G.; Lokavarapu, H. V.

    2016-12-01

    We present the results of three standard benchmarks for the new active tracer particle algorithm in ASPECT. The three benchmarks are SolKz, SolCx, and SolVI (also known as the 'inclusion benchmark') first proposed by Duretz, May, Gerya, and Tackley (G Cubed, 2011) and in subsequent work by Theilman, May, and Kaus (Pure and Applied Geophysics, 2014). Each of the three benchmarks compares the accuracy of the numerical solution to a steady (time-independent) solution of the incompressible Stokes equations with a known exact solution. These benchmarks are specifically designed to test the accuracy and effectiveness of the numerical method when the viscosity varies up to six orders of magnitude. ASPECT has been shown to converge to the exact solution of each of these benchmarks at the correct design rate when all of the flow variables, including the density and viscosity, are discretized on the underlying finite element grid (Krobichler, Heister, and Bangerth, GJI, 2012). In our work we discretize the density and viscosity by initially placing the true values of the density and viscosity at the intial particle positions. At each time step, including the initialization step, the density and viscosity are interpolated from the particles onto the finite element grid. The resulting Stokes system is solved for the velocity and pressure, and the particle positions are advanced in time according to this new, numerical, velocity field. Note that this procedure effectively changes a steady solution of the Stokes equaton (i.e., one that is independent of time) to a solution of the Stokes equations that is time dependent. Furthermore, the accuracy of the active tracer particle algorithm now also depends on the accuracy of the interpolation algorithm and of the numerical method one uses to advance the particle positions in time. Finally, we will present new interpolation algorithms designed to increase the overall accuracy of the active tracer algorithms in ASPECT and interpolation algotithms designed to conserve properties, such as mass density, that are being carried by the particles.

  8. X-space MPI: magnetic nanoparticles for safe medical imaging.

    PubMed

    Goodwill, Patrick William; Saritas, Emine Ulku; Croft, Laura Rose; Kim, Tyson N; Krishnan, Kannan M; Schaffer, David V; Conolly, Steven M

    2012-07-24

    One quarter of all iodinated contrast X-ray clinical imaging studies are now performed on Chronic Kidney Disease (CKD) patients. Unfortunately, the iodine contrast agent used in X-ray is often toxic to CKD patients' weak kidneys, leading to significant morbidity and mortality. Hence, we are pioneering a new medical imaging method, called Magnetic Particle Imaging (MPI), to replace X-ray and CT iodinated angiography, especially for CKD patients. MPI uses magnetic nanoparticle contrast agents that are much safer than iodine for CKD patients. MPI already offers superb contrast and extraordinary sensitivity. The iron oxide nanoparticle tracers required for MPI are also used in MRI, and some are already approved for human use, but the contrast agents are far more effective at illuminating blood vessels when used in the MPI modality. We have recently developed a systems theoretic framework for MPI called x-space MPI, which has already dramatically improved the speed and robustness of MPI image reconstruction. X-space MPI has allowed us to optimize the hardware for fi ve MPI scanners. Moreover, x-space MPI provides a powerful framework for optimizing the size and magnetic properties of the iron oxide nanoparticle tracers used in MPI. Currently MPI nanoparticles have diameters in the 10-20 nanometer range, enabling millimeter-scale resolution in small animals. X-space MPI theory predicts that larger nanoparticles could enable up to 250 micrometer resolution imaging, which would represent a major breakthrough in safe imaging for CKD patients.

  9. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging

    PubMed Central

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St. Lawrence, K; Pogue, B W

    2014-01-01

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labelled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in 4 mice was estimated using dual-tracer kinetic modelling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured. PMID:24743262

  10. Impact of solvent granularity and layering on tracer hydrodynamics in confinement.

    PubMed

    Bollinger, Jonathan A; Carmer, James; Jain, Avni; Truskett, Thomas M

    2016-11-28

    Classic hydrodynamic arguments establish that when a spherical tracer particle is suspended between parallel walls, tracer-wall coupling mediated by the solvent will cause the tracer to exhibit position-dependent diffusivity. We investigate how the diffusivity profiles of confined tracers are impacted by the diameter size-ratio of the tracer to solvent: starting from the classic limit of infinite size-ratio (i.e., continuum solvent), we consider size-ratios of four or less to examine how hydrodynamic predictions are disrupted for systems where the tracer and solvent are of similar scale. We use computer simulations and techniques based on the Fokker-Planck formalism to calculate the diffusivity profiles of hard-sphere tracer particles in hard-sphere solvents, focusing on the dynamics perpendicular to the walls. Given wall separations of several tracer diameters, we first consider confinement between hard walls, where anisotropic structuring at the solvent lengthscale generates inhomogeneity in the tracer free-energy landscape and undermines hydrodynamic predictions locally. We then introduce confining planes that we term transparent walls, which restrict tracer and solvent center-accessibilities while completely eliminating static anisotropy, and reveal position-dependent signatures in tracer diffusivity solely attributable to confinement. With or without suppressing static heterogeneity, we find that tracer diffusivity increasingly deviates on a local basis from hydrodynamic predictions at smaller size-ratios. However, hydrodynamic theory still approximately captures spatially-averaged dynamics across the pores even for very small tracer-solvent size-ratios over a wide range of solvent densities and wall separations.

  11. Development of Cu-64 labeled EGF for In Vivo PET Imaging of EGFR Expression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Backer, Joseph M.

    2009-07-12

    In this project we proposed to establish feasibility of the development of targeted tracers for radionuclide imaging of epidermal growth factor receptors (EGFR) in cancer patients. The significance and impact of the proposed radiotracers are determined by the crucial role that EGFR plays in many cancers and by the rapid entrance of EGFR-inhibiting drugs into clinic. Clinical experience, however, revealed that only 10-25% of patients that are defined as EGFR-positive by immunohistochemical analysis respond to EGFR-directed therapeutics and there is poor correlation between EGFR immunohistochemistry and treatment. Therefore, for more efficacious use of EGFR-targeting therapeutics, there is a need formore » information about EGFR activity in patients. We hypothesized that radionuclide imaging of functionally active EGFR will provide such information and would allow for 1) rational patient stratification, 2) rapid monitoring of responses to therapy, and 3) development of personalized treatment regimens. We hypothesized that tracers based epidermal growth factor (EGF), a natural EGFR ligand, as a targeting vector would be particularly advantageous. First, only functionally active and therefore critical for disease progression EGFRs will bind and internalize an EGF-based tracer. Second, continuous internalization of EGF-based tracers by recyclable EGFR would lead to intracellular accumulation of radionuclide and improved signal-to-background ratio. Third, small size of EGF relative to antibodies would facilitate tumor penetration with vastly better non-specific soft tissue and blood clearance rates. Fourth, as a human protein, EGF is not expected to be immunogenic. Finally, at the beginning of this project, we have already engineered and expressed functionally active EGF with an N-terminal Cys-tag for site-specific conjugation of various payloads, including radionuclide chelators. In the Phase I of this project, in collaboration with Dr. Blankenberg’s group at Stanford University, 1. To synthesize and validate in vitro EGF-PEG-DOTA conjugate. The key accomplishment in this part of the project is synthesis of functionally active EGF-PEG-DOTA, construction, expression, and purification of functionally active Cys-tagged dimeric EGF (dEGF) and synthesis of corresponding dEGF-PEG-DOTA, development of protocols for radiolabeling EGF-PEG-DOTA and dEGF-PEG-DOTA with 64Cu. 2. To establish clearance, biodistribution, and stability of EGF-based PET 64Cu radiotracer. These characteristics are established for both EGF-PEG-DOTA/64Cu and dEGF-PEG-DOTA/64Cu and found to be comparable with reported data on 64Cu-radiolabeled antibodies. 3. To evaluate PET tumor imaging with EGF-based 64Cu radiotracer in mouse tumor models. Tumor imaging was evaluated in orthotopic human MDA231luc breast carcinoma model in SCID mice. Tracers accumulated in tumor area, allowing for detection of as small as few millimeter tumors. The Technical Objectives of the projects are accomplished and the results are published in Bioconjugate Chem. 20, 742, 2009.« less

  12. Evaluation of the Possible Utilization of 68Ga-DOTATOC in Diagnosis of Adenocarcinoma Breast Cancer.

    PubMed

    Zolghadri, Samaneh; Naderi, Mojdeh; Yousefnia, Hassan; Alirezapour, Behrouz; Beiki, Davood

    2018-01-01

    Studies have indicated advantageous properties of [DOTA-DPhe 1 , Tyr 3 ] octreotide (DOTATOC) in tumor models and labeling with gallium. Breast cancer is the second leading cause of cancer mortality in women, and most of these cancers are often an adenocarcinoma. Due to the importance of target to non-target ratios in the efficacy of diagnosis, the pharmacokinetic of 68 Ga-DOTATOC in an adenocarcinoma breast cancer animal model was studied in this research, and the optimized time for imaging was determined. 68 Ga was obtained from 68 Ge/ 68 Ga generator. The complex was prepared at optimized conditions. Radiochemical purity of the complex was checked using both HPLC and ITLC methods. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer. Also, PET/CT imaging was performed up to 120 min post injection. The complex was produced with radiochemical purity of greater than 98% and specific activity of about 40 GBq/mM at optimized conditions. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer indicated fast blood clearance and significant uptake in the tumor. Significant tumor: blood and tumor:muscle uptake ratios were observed even at early times post-injection. PET/CT images were also confirmed the considerable accumulation of the tracer in the tumor. Generally, the results proved the possible application of the radiolabelled complex for the detection of the adenocarcinoma breast cancer and according to the pharmacokenitic data, the suitable time for imaging was determined as at least 30 min after injection.

  13. Evaluation of the Possible Utilization of 68Ga-DOTATOC in Diagnosis of Adenocarcinoma Breast Cancer

    PubMed Central

    Zolghadri, Samaneh; Naderi, Mojdeh; Yousefnia, Hassan; Alirezapour, Behrouz; Beiki, Davood

    2018-01-01

    Objective(s): Studies have indicated advantageous properties of [DOTA-DPhe1, Tyr3] octreotide (DOTATOC) in tumor models and labeling with gallium. Breast cancer is the second leading cause of cancer mortality in women, and most of these cancers are often an adenocarcinoma. Due to the importance of target to non-target ratios in the efficacy of diagnosis, the pharmacokinetic of 68Ga-DOTATOC in an adenocarcinoma breast cancer animal model was studied in this research, and the optimized time for imaging was determined. Methods: 68Ga was obtained from 68Ge/68Ga generator. The complex was prepared at optimized conditions. Radiochemical purity of the complex was checked using both HPLC and ITLC methods. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer. Also, PET/CT imaging was performed up to 120 min post injection. Results: The complex was produced with radiochemical purity of greater than 98% and specific activity of about 40 GBq/mM at optimized conditions. Biodistribution of the complex was studied in BALB/c mice bearing adenocarcinoma breast cancer indicated fast blood clearance and significant uptake in the tumor. Significant tumor: blood and tumor:muscle uptake ratios were observed even at early times post-injection. PET/CT images were also confirmed the considerable accumulation of the tracer in the tumor. Conclusion: Generally, the results proved the possible application of the radiolabelled complex for the detection of the adenocarcinoma breast cancer and according to the pharmacokenitic data, the suitable time for imaging was determined as at least 30 min after injection. PMID:29333466

  14. Electrodeposition of actinide compounds from an aqueous ammonium acetate matrix. Experimental development and optimization

    DOE PAGES

    Boll, Rose Ann; Matos, Milan; Torrico, Matthew N.

    2015-03-27

    Electrodeposition is a technique that is routinely employed in nuclear research for the preparation of thin solid films of actinide materials which can be used in accelerator beam bombardments, irradiation studies, or as radioactive sources. The present study investigates the deposition of both lanthanides and actinides from an aqueous ammonium acetate electrolyte matrix. Electrodepositions were performed primarily on stainless steel disks; with yield analysis evaluated using -spectroscopy. Experimental parameters were studied and modified in order to optimize the uniformity and adherence of the deposition while maximizing the yield. The initial development utilized samarium as the plating material, with and withoutmore » a radioactive tracer. As a result, surface characterization studies were performed by scanning electron microscopy, electron microprobe analysis, radiographic imaging, and x-ray diffraction.« less

  15. Visualizing and quantifying dose distribution in a UV reactor using three-dimensional laser-induced fluorescence.

    PubMed

    Gandhi, Varun N; Roberts, Philip J W; Kim, Jae-Hong

    2012-12-18

    Evaluating the performance of typical water treatment UV reactors is challenging due to the complexity in assessing spatial and temporal variation of UV fluence, resulting from highly unsteady, turbulent nature of flow and variation in UV intensity. In this study, three-dimensional laser-induced fluorescence (3DLIF) was applied to visualize and quantitatively analyze a lab-scale UV reactor consisting of one lamp sleeve placed perpendicular to flow. Mapping the spatial and temporal fluence delivery and MS2 inactivation revealed the highest local fluence in the wake zone due to longer residence time and higher UV exposure, while the lowest local fluence occurred in a region near the walls due to short-circuiting flow and lower UV fluence rate. Comparing the tracer based decomposition between hydrodynamics and IT revealed similar coherent structures showing the dependency of fluence delivery on the reactor flow. The location of tracer injection, varying the height and upstream distance from the lamp center, was found to significantly affect the UV fluence received by the tracer. A Lagrangian-based analysis was also employed to predict the fluence along specific paths of travel, which agreed with the experiments. The 3DLIF technique developed in this study provides new insight on dose delivery that fluctuates both spatially and temporally and is expected to aid design and optimization of UV reactors as well as validate computational fluid dynamics models that are widely used to simulate UV reactor performances.

  16. Investigation of injection dose and camera integration time on quantifying pharmacokinetics of a Cy5.5-GX1 probe with dynamic fluorescence imaging in vivo

    NASA Astrophysics Data System (ADS)

    Dai, Yunpeng; Chen, Xueli; Yin, Jipeng; Kang, Xiaoyu; Wang, Guodong; Zhang, Xianghan; Nie, Yongzhan; Wu, Kaichun; Liang, Jimin

    2016-08-01

    The aim of this article is to investigate the influence of a tracer injection dose (ID) and camera integration time (IT) on quantifying pharmacokinetics of Cy5.5-GX1 in gastric cancer BGC-823 cell xenografted mice. Based on three factors, including whether or not to inject free GX1, the ID of Cy5.5-GX1, and the camera IT, 32 mice were randomly divided into eight groups and received 60-min dynamic fluorescence imaging. Gurfinkel exponential model (GEXPM) and Lammertsma simplified reference tissue model (SRTM) combined with a singular value decomposition analysis were used to quantitatively analyze the acquired dynamic fluorescent images. The binding potential (Bp) and the sum of the pharmacokinetic rate constants (SKRC) of Cy5.5-GX1 were determined by the SRTM and EXPM, respectively. In the tumor region, the SKRC value exhibited an obvious trend with change in the tracer ID, but the Bp value was not sensitive to it. Both the Bp and SKRC values were independent of the camera IT. In addition, the ratio of the tumor-to-muscle region was correlated with the camera IT but was independent of the tracer ID. Dynamic fluorescence imaging in conjunction with a kinetic analysis may provide more quantitative information than static fluorescence imaging, especially for a priori information on the optimal ID of targeted probes for individual therapy.

  17. Determination of the Isotopic Enrichment of 13C- and 2H-Labeled Tracers of Glucose Using High-Resolution Mass Spectrometry: Application to Dual- and Triple-Tracer Studies.

    PubMed

    Trötzmüller, Martin; Triebl, Alexander; Ajsic, Amra; Hartler, Jürgen; Köfeler, Harald; Regittnig, Werner

    2017-11-21

    Multiple-tracer approaches for investigating glucose metabolism in humans usually involve the administration of stable and radioactive glucose tracers and the subsequent determination of tracer enrichments in sampled blood. When using conventional, low-resolution mass spectrometry (LRMS), the number of spectral interferences rises rapidly with the number of stable tracers employed. Thus, in LRMS, both computational effort and statistical uncertainties associated with the correction for spectral interferences limit the number of stable tracers that can be simultaneously employed (usually two). Here we show that these limitations can be overcome by applying high-resolution mass spectrometry (HRMS). The HRMS method presented is based on the use of an Orbitrap mass spectrometer operated at a mass resolution of 100 000 to allow electrospray-generated ions of the deprotonated glucose molecules to be monitored at their exact masses. The tracer enrichment determination in blood plasma is demonstrated for several triple combinations of 13 C- and 2 H-labeled glucose tracers (e.g., [1- 2 H 1 ]-, [6,6- 2 H 2 ]-, [1,6- 13 C 2 ]glucose). For each combination it is shown that ions arising from 2 H-labeled tracers are completely differentiated from those arising from 13 C-labeled tracers, thereby allowing the enrichment of a tracer to be simply calculated from the observed ion intensities using a standard curve with curve parameters unaffected by the presence of other tracers. For each tracer, the HRMS method exhibits low limits of detection and good repeatability in the tested 0.1-15.0% enrichment range. Additionally, due to short sample preparation and analysis times, the method is well-suited for high-throughput determination of multiple glucose tracer enrichments in plasma samples.

  18. Shading responses of carbon allocation dynamics in mountain grassland

    NASA Astrophysics Data System (ADS)

    Bahn, M.; Lattanzi, F. A.; Brueggemann, N.; Siegwolf, R. T.; Richter, A.

    2012-12-01

    Carbon (C) allocation strongly influences plant and soil processes. Global environmental changes can alter source - sink relations of plants with potential implications for C allocation. Short-term C allocation dynamics in ecosystems and their responses to environmental changes are still poorly understood. To analyze effects of assimilate supply (i.e. C source strength) on ecosystem C allocation dynamics and the role of non-structural carbohydrates, canopy sections of a mountain meadow were pulse labeled with 13CO2 and subsequently shaded for a week or left unshaded (control). Tracer dynamics in above- and belowground sucrose and starch pools were analysed and coupled using compartmental modelling. The hypothesis was tested that shading affects tracer dynamics in non-structural carbohydrates and diminishes the transfer of recently assimilated C to roots and their storage pools. In unshaded plots up to 40% of assimilated C was routed through short-term storage in shoot starch and sucrose to buffer day / night cycles in photosynthesis. Shoot- and root sucrose and shoot starch were kinetically closely related pools. The tracer dynamics of the modelled root sucrose pool corresponded well with those in soil CO2 efflux. Root starch played no role in buffering day / night cycles and likely acted as a seasonal store. Shading strongly reduced sucrose and starch concentrations in shoots but not roots and resulted in a massive reduction of leaf respiration, while root respiration was much less diminished. Shading affected tracer dynamics in sucrose and starch of shoots: shoot starch rapidly lost tracer, while sucrose transiently increased its tracer content. Surprisingly, shading did not alter the dynamics of root carbohydrates. Even under severe C limitation after one week of shading, tracer C continued to be incorporated in root starch. Also the amount of 13C incorporated in phospholipid fatty acids of soil microbial communities was not reduced by shading, though its residence time followed a changed pattern, suggesting an influence of C source strength on the utilization and turnover of recent plant-derived C. These findings will be discussed in the broader context of plant and ecosystem carbon allocation, with particular reference to the concepts of 'source versus sink strength' and 'passive versus active C storage'.

  19. Radon as a natural tracer for underwater cave exploration and hypogenic cave formation

    NASA Astrophysics Data System (ADS)

    Csondor, Katalin; Erőss, Anita; Horváth, Ákos; Szieberth, Dénes

    2017-04-01

    Using 222Rn as a natural tracer is a novel approach in underwater cave exploration and in the research of active hypogenic caves. The research area, the Molnár János cave is one of the largest caves of an unique hypogenic karst system, the Buda Thermal Karst (Budapest, Hungary). The cave system is mainly characterized by water-filled passages. The cave is located at one of the main discharge areas of the Buda Thermal Karst and the major outflow point of the waters of the cave system is the Boltív spring, which feeds the artificial Malom Lake. Previous complex hydrogeological studies and radon measurements in the cave system and in the spring established the highest radon concentration (71 Bq/L, where the average is 44 Bq/L) in the springwater. The origin of radon was identified in the form of iron-hydroxide containing biofilms, which form by mixing of waters and efficiently adsorb radium from the thermal water component and cause local radon anomalies. Since mixing of waters is responsible for the formation of the cave as well, these iron-hydroxide containing biofilms and consequently high radon concentrations mark the active cave forming zones. The aim of the study was to use the radon as a natural tracer to locate active mixing and cave forming zones. Based on previous radon measurements it is supposed that the active mixing and cave forming zone has to be close to the spring, since the highest radon concentration was measured there. Therefore, the radon activity concentration mapping was carried out with the help of divers and involving that part of the cave which closest to the spring. Based on our measurements the highest radon concentration (84 Bq/L) ever was achieved in the springwater. Based on the radon concentration distribution direct connection and active karst conduit was established between the spring and the deepest room of the researched part of the cave, which was verified by artificial tracer as well. However, the distribution of radon in the cave passages shows lower concentrations (18-46 Bq/L) compared to the spring, therefore an addition deep inflow from a hitherto unknown cave passages is assumed, from which waters with high radon content arrive to the spring. These passages are supposed to be in the active cave formation (mixing) zone. The Buda Thermal Karst research was funded by the Hungarian Scientific Research Fund under the grant agreement no. NK 101356.

  20. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  1. Accounting for pharmacokinetic differences in dual-tracer receptor density imaging.

    PubMed

    Tichauer, K M; Diop, M; Elliott, J T; Samkoe, K S; Hasan, T; St Lawrence, K; Pogue, B W

    2014-05-21

    Dual-tracer molecular imaging is a powerful approach to quantify receptor expression in a wide range of tissues by using an untargeted tracer to account for any nonspecific uptake of a molecular-targeted tracer. This approach has previously required the pharmacokinetics of the receptor-targeted and untargeted tracers to be identical, requiring careful selection of an ideal untargeted tracer for any given targeted tracer. In this study, methodology capable of correcting for tracer differences in arterial input functions, as well as binding-independent delivery and retention, is derived and evaluated in a mouse U251 glioma xenograft model using an Affibody tracer targeted to epidermal growth factor receptor (EGFR), a cell membrane receptor overexpressed in many cancers. Simulations demonstrated that blood, and to a lesser extent vascular-permeability, pharmacokinetic differences between targeted and untargeted tracers could be quantified by deconvolving the uptakes of the two tracers in a region of interest devoid of targeted tracer binding, and therefore corrected for, by convolving the uptake of the untargeted tracer in all regions of interest by the product of the deconvolution. Using fluorescently labeled, EGFR-targeted and untargeted Affibodies (known to have different blood clearance rates), the average tumor concentration of EGFR in four mice was estimated using dual-tracer kinetic modeling to be 3.9 ± 2.4 nM compared to an expected concentration of 2.0 ± 0.4 nM. However, with deconvolution correction a more equivalent EGFR concentration of 2.0 ± 0.4 nM was measured.

  2. Chemical Tracer Methods: Chapter 7

    USGS Publications Warehouse

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  3. Multiple Time-Point 68Ga-PSMA I&T PET/CT for Characterization of Primary Prostate Cancer: Value of Early Dynamic and Delayed Imaging.

    PubMed

    Schmuck, Sebastian; Mamach, Martin; Wilke, Florian; von Klot, Christoph A; Henkenberens, Christoph; Thackeray, James T; Sohns, Jan M; Geworski, Lilli; Ross, Tobias L; Wester, Hans-Juergen; Christiansen, Hans; Bengel, Frank M; Derlin, Thorsten

    2017-06-01

    The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P < 0.01). The influx rate (Ki) was higher in prostate cancer than in reference prostate gland (0.055 [r = 0.998] vs 0.017 [r = 0.996]). Primary prostate cancer is readily identified on early dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.

  4. Dual-Readout Immunochromatographic Assay by Utilizing MnO 2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ouyang, Hui; Lu, Qian; Wang, Wenwen

    Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye asmore » a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.« less

  5. Resazurin as a Proxy for Estimating Stream Respiration

    NASA Astrophysics Data System (ADS)

    Gonzalez Pinzon, R. A.; Haggerty, R.; Argerich, A.; Briggs, M.; Lautz, L. K.; Lemke, D.; Hare, D. K.

    2010-12-01

    Hydrologic retention in stream ecosystems favors the reactions of solutes and nutrients in metabolically active transient storage (MATS) zones. These zones are hot spots where metabolic activity is expected to contribute significantly to ecosystem respiration. We compare the results of a series of coinjections of resazurin (Raz) as a redox sensitive tracer, and NaCl as a conservative tracer to investigate the function of MATS zones. Raz is a dye that undergoes an irreversible reduction to resorufin (Rru) when exposed to aerobic respiration. To characterize the transformation of Raz we measured the BTC of the tracers at the boundary conditions, and during plateau concentrations we sampled the longitudinal profile of surface water. We also used the two-station diel technique to quantify gross primary production (GPP) and community respiration (CR) within the reaches. Injections have been performed in streams with different morphology, streambed composition, and riparian vegetation in Oregon-USA (WS 1 and WS 3 in the HJ Andrews Forest LTER, and Drift Creek), Spain (Riera de Santa Fe del Montseny, Catalonia) and Wyoming-USA (Cherry Creek). The results support the idea that under different ranges of community respiration, the transformation of Raz to Rru is a proxy for quantifying MATS, characterizing spatial heterogeneity in respiration rates, and ultimately, could be used to estimate ecosystem respiration in environments where direct measurement is challenging.

  6. Cerebral adenosine A₁ receptors are upregulated in rodent encephalitis.

    PubMed

    Paul, Soumen; Khanapur, Shivashankar; Boersma, Wytske; Sijbesma, Jurgen W; Ishiwata, Kiichi; Elsinga, Philip H; Meerlo, Peter; Doorduin, Janine; Dierckx, Rudi A; van Waarde, Aren

    2014-05-15

    Adenosine A1 receptors (A1Rs) are implied in the modulation of neuroinflammation. Activation of cerebral A1Rs acts as a brake on the microglial response after traumatic brain injury and has neuroprotective properties in animal models of Parkinson's disease and multiple sclerosis. Neuroinflammatory processes in turn may affect the expression of A1Rs, but the available data is limited and inconsistent. Here, we applied an animal model of encephalitis to assess how neuroinflammation affects the expression of A1Rs. Two groups of animals were studied: Infected rats (n=7) were intranasally inoculated with herpes simplex virus-1 (HSV-1, 1 × 10(7) plaque forming units), sham-infected rats (n=6) received only phosphate-buffered saline. Six or seven days later, microPET scans (60 min with arterial blood sampling) were made using the tracer 8-dicyclopropyl-1-(11)C-methyl-3-propyl-xanthine ((11)C-MPDX). Tracer clearance from plasma and partition coefficient (K₁/k₂ estimated from a 2-tissue compartment model fit) were not significantly altered after virus infection. PET tracer distribution volume calculated from a Logan plot was significantly increased in the hippocampus (+37%) and medulla (+27%) of virus infected rats. Tracer binding potential (k₃/k₄ estimated from the model fit) was significantly increased in the cerebellum (+87%) and the medulla (+148%) which may indicate increased A1R expression. This was confirmed by immunohistochemical analysis showing a strong increase of A1R immunoreactivity in the cerebellum of HSV-1-infected rats. Both the quantitative PET data and immunohistochemical analysis indicate that A1Rs are upregulated in brain areas where active virus is present. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. The use of 123I-labeled heptadecanoic acid (HDA) as metabolic tracer: preliminary report.

    PubMed

    Dudczak, R; Kletter, K; Frischauf, H; Losert, U; Angelberger, P; Schmoliner, R

    1984-01-01

    The feasibility of using 123I-heptadecanoic acid (HDA) as a metabolic tracer was studied. Different administration routes of HDA were compared. An intracoronary bolus injection was given to calves (n = 3), and an intravenous injection was given to patients (n = 4). In addition, we examined the influence of 4-h halothane anesthesia in calves and in patients the impact of an insulin (1.5 IU/kg) + glucose (1.5 g/kg) infusion on the myocardial kinetics of HDA. Data were accumulated with a scintillation probe in calves (t = 50 min) and a gamma camera in patients (t = 70 min). In calves after an intracoronary bolus injection of HDA the myocardial time-activity curve could be described by two exponentials. The mean elimination half-time of the initial phase (ta 1/2) was 7.3 min and that of the second phase (tb 1/2) was 35 min. The ratio of the size of the initial and second component at to was 0.93. Halothane anesthesia prolonged the elimination half-times and reduced the component ratio. The biphasic behavior of the myocardial time-activity curve was maintained in patients after intravenous administration of HDA under basal conditions (initial ta 1/2 = 8.4 min). However, during infusion of insulin + glucose the decline in the myocardial activity was prolonged and monoexponential. This data shows that insulin glucose, interfering with fatty acid metabolism, influences the myocardial washout of HDA, and thus support its use as a metabolic tracer.

  8. Direct Quantification of Microbial Community Respiration along a Contamination Gradient using a novel Hydrologic Smart Tracer

    NASA Astrophysics Data System (ADS)

    Stanaway, D. J.; Haggerty, R.; Feris, K. P.

    2010-12-01

    Heavy metal contamination in lotic ecosystems is a major health and environmental concern worldwide. The Resazurin Resorufin (Raz Rru) Smart Tracer system (Haggerty et al., 2008) provides a novel approach to test current models of microbial ecosystem response to chronic stressors such as heavy metals. These models predict that functional redundancy of metabolic capabilities of community members (e.g. respiration rate and enzyme activity) will compensate for decreases in species diversity until a stress threshold is reached. At this point, species diversity and function are expected to decline rapidly. Contrary to this model, microbial communities of the Clark Fork River (CF), Montana, demonstrate high levels of species diversity along the contamination gradient, whereas community function is inversely proportional to the level of contamination. The Raz Rru tool, a metabolically reactive hydrologic tracer, allows for direct quantification of in-situ microbial respiration rates. Therefore, this tool provides an opportunity to build upon studies of ecosystem response to contamination previously limited to extrapolation of point scale measurements to reach scale processes. The Raz Rru tool is used here to quantify the magnitude of metal induced limits on heterotrophic microbial respiration in communities that have evolved to different levels of chronic metal exposure. In this way we propose to be able to test a novel hypothesis concerning the nature of evolution of community processes to chronic stress and persistent environmental pollutants. Specifically, we hypothesize that metal contamination produces a measureable metabolic cost to both tolerant and intolerant communities. To test this hypothesis, rates of respiration associated with hyporheic sediments, supporting intact microbial communities, were quantified in the presence and absence of an acute Cd exposure in column experiments. Hyporheic sediment was collected from differently contaminated locations within the CF and compared to sediment from pristine reference sites. The biological reduction rate of Raz to Rru, K_12 in the Advection Dispersion Equation (ADE) below, represents rates of sediment associated heterotrophic respiration. ∂C_Raz}/{∂t} = {α_Lν}/{R} {∂^2C_Raz}/{∂x^2} - {ν}/{R} {∂C_Raz}/{∂x} - k_1C_Raz -k_12C_Raz [/tex] {∂C_Rru}/{∂t} = {α_Lν}/{R} {∂^2C_Rru}/{∂x^2} -{ν}/{R} {∂C_Rru}/{∂x} - k_2C_Rru + k_12 {M_Rru}/{M_Raz}CRaz [/tex] The Raz-Rru ADE will be optimized through the Markov Chain Monte Carlo method. Preliminary analysis of Cl^- tracer data provides input estimation of physical parameters, populating the hydrological terms of the ADE necessary for elucidation of K_12. It is expected that sediment metal content and K_12 are inversely related and that acute Cd exposure will negatively affect K_12 of both communities, with communities inhabiting metal contaminated sediments demonstrating a smaller reduction in K_12. This project has the potential to contribute to a revised theory of community response to metal induced chronic ecosystem stress, while contributing to the further development and application of the Raz Rru Smart Tracer system.

  9. Comparison of three dimeric 18F-AlF-NOTA-RGD tracers.

    PubMed

    Guo, Jinxia; Lang, Lixin; Hu, Shuo; Guo, Ning; Zhu, Lei; Sun, Zhongchan; Ma, Ying; Kiesewetter, Dale O; Niu, Gang; Xie, Qingguo; Chen, Xiaoyuan

    2014-04-01

    RGD peptide-based radiotracers are well established as integrin αvβ3 imaging probes to evaluate tumor angiogenesis or tissue remodeling after ischemia or infarction. In order to optimize the labeling process and pharmacokinetics of the imaging probes, we synthesized three dimeric RGD peptides with or without PEGylation and performed in vivo screening. Radiolabeling was achieved through the reaction of F-18 aluminum-fluoride complex with the cyclic chelator, 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA). Three imaging probes were synthesized as (18)F-AlF-NOTA-E[c(RGDfK)]2, (18)F-AlF-NOTA-PEG4-E[c(RGDfK)]2, and (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2. The receptor binding affinity was determined by competitive cell binding assay, and the stability was evaluated by mouse serum incubation. Tumor uptake and whole body distribution of the three tracers were compared through direct tissue sampling and PET quantification of U87MG tumor-bearing mice. All three compounds remained intact after 120 min incubation with mouse serum. They all had a rapid and relatively high tracer uptake in U87MG tumors with good target-to-background ratios. Compared with the other two tracers, (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2 had the highest tumor uptake and the lowest accumulation in the liver. The integrin receptor specificity was confirmed by co-injection of unlabeled dimeric RGD peptide. The rapid one-step radiolabeling strategy by the complexation of (18)F-aluminum fluoride with NOTA-peptide conjugates was successfully applied to synthesize three dimeric RGD peptides. Among the three probes developed, (18)F-AlF-NOTA-E[PEG4-c(RGDfk)]2 with relatively low liver uptake and high tumor accumulation appears to be a promising candidate for further translational research.

  10. Feasibility and diagnostic performance of dual-tracer-guided sentinel lymph node biopsy in cT1-2N0M0 gastric cancer: a systematic review and meta-analysis of diagnostic studies.

    PubMed

    Huang, Ling; Wei, Tao; Chen, Junjun; Zhou, Donghui

    2017-05-16

    Dual-tracer-guided sentinel lymph node (SLN) biopsy may provide a promising diagnostic tool to assess accurately the status of lymph node metastasis in the surgical operation and assure the oncologic safety of the function or stomach preserving surgery. The diagnostic performance of this technology in recent studies varied. Thus, we conducted this meta-analysis. This systematic review and meta-analysis was registered at the PROSPERO. Eligible studies were searched in the PubMed, EMBASE, Web of Knowledge, and Cochrane Library databases. A random-effect model was used to pool the data. Summary receiver operator characteristic curves, analysis for publication bias, meta-regression, and subgroup analysis were also performed. The pooled SLN identification rate and sensitivity were 0.97 and 0.89. 99m Tc-human serum albumin with indocyanine green (ICG), 99m Tc-antimony sulfur colloid with ICG, performing SLN biopsy ≥15 min after dye injection, an SLN ≥5, the basin dissection, laparoscopic surgery, in studies conducted in Japan and studies published after 2012, were associated with higher sensitivity. CT1 stage, performing SLN biopsy ≥15 min after dye injection, in studies conducted in Japan and studies published after 2012, were related with a higher identification rate. Dual tracer is promising in SLN biopsy in gastric cancer, and the clinical application of SLN biopsy should be limited to the patients of cT1N0M0 gastric cancer. The combination of 99m Tc-human serum albumin and ICG as well as the combination of 99m Tc-antimony sulfur colloid and ICG may be the optimal tracer combination. However, it seems not justified to put this technique into routine clinical application recently. Some factors that might enhance diagnostic value are identified.

  11. Kinetic modeling and long-term test-retest reproducibility of the mGluR5 PET tracer 18F-FPEB in human brain.

    PubMed

    Leurquin-Sterk, Gil; Postnov, Andrey; de Laat, Bart; Casteels, Cindy; Celen, Sofie; Crunelle, Cleo L; Bormans, Guy; Koole, Michel; Van Laere, Koen

    2016-04-01

    (18)F-FPEB is a promising PET tracer for studying the metabotropic glutamate subtype 5 receptor (mGluR5) expression in neuropsychiatric disorders. To assess the potential of (18)F-FPEB for longitudinal mGluR5 evaluation in patient studies, we evaluated the long-term test-retest reproducibility using various kinetic models in the human brain. Nine healthy volunteers underwent consecutive scans separated by a 6-month period. Dynamic PET was combined with arterial sampling and radiometabolite analysis. Total distribution volume (V(T)) and nondisplaceable binding potential (BP(ND)) were derived from a two-tissue compartment model without constraints (2TCM) and with constraining the K(1)/k(2) ratio to the value of either cerebellum (2TCM-CBL) or pons (2TCM-PONS). The effect of fitting different functions to the tracer parent fractions and reducing scan duration were assessed. Regional absolute test-retest variability (aTRV), coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were computed. The 2TCM-CBL showed best fits. The mean 6-month aTRV of V(T) ranged from 8 to 13% (CR < 25%) with ICC > 0.6 for all kinetic models. BPND from 2TCM-CBL with a sigmoid fit for the parent fractions showed the best reproducibility, with aTRV ≤ 7% (CR < 16%) and ICC > 0.9 in most regions. Reducing the scan duration from 90 to 60 min did not affect reproducibility. These results demonstrate for the first time that (18)F-FPEB brain PET has good long-term reproducibility, therefore validating its use to monitor mGluR5 expression in longitudinal clinical studies. We suggest a 2TCM-CBL with fitting a sigmoid function to the parent fractions to be optimal for this tracer. © 2016 Wiley Periodicals, Inc.

  12. Radiosynthesis and in vivo evaluation of a series of substituted 11C-phenethylamines as 5-HT (2A) agonist PET tracers.

    PubMed

    Ettrup, Anders; Hansen, Martin; Santini, Martin A; Paine, James; Gillings, Nic; Palner, Mikael; Lehel, Szabolcs; Herth, Matthias M; Madsen, Jacob; Kristensen, Jesper; Begtrup, Mikael; Knudsen, Gitte M

    2011-04-01

    Positron emission tomography (PET) imaging of serotonin 2A (5-HT(2A)) receptors with agonist tracers holds promise for the selective labelling of 5-HT(2A) receptors in their high-affinity state. We have previously validated [(11)C]Cimbi-5 and found that it is a 5-HT(2A) receptor agonist PET tracer. In an attempt to further optimize the target-to-background binding ratio, we modified the chemical structure of the phenethylamine backbone and carbon-11 labelling site of [(11)C]Cimbi-5 in different ways. Here, we present the in vivo validation of nine novel 5-HT(2A) receptor agonist PET tracers in the pig brain. Each radiotracer was injected intravenously into anaesthetized Danish Landrace pigs, and the pigs were subsequently scanned for 90 min in a high-resolution research tomography scanner. To evaluate 5-HT(2A) receptor binding, cortical nondisplaceable binding potentials (BP(ND)) were calculated using the simplified reference tissue model with the cerebellum as a reference region. After intravenous injection, all compounds entered the brain and distributed preferentially into the cortical areas, in accordance with the known 5-HT(2A) receptor distribution. The largest target-to-background binding ratio was found for [(11)C]Cimbi-36 which also had a high brain uptake compared to its analogues. The cortical binding of [(11)C]Cimbi-36 was decreased by pretreatment with ketanserin, supporting 5-HT(2A) receptor selectivity in vivo. [(11)C]Cimbi-82 and [(11)C]Cimbi-21 showed lower cortical BP(ND), while [(11)C]Cimbi-27, [(11)C]Cimbi-29, [(11)C]Cimbi-31 and [(11)C]Cimbi-88 gave rise to cortical BP(ND) similar to that of [(11)C]Cimbi-5. [(11)C]Cimbi-36 is currently the most promising candidate for investigation of 5-HT(2A) receptor agonist binding in the living human brain with PET.

  13. In vivo PET/CT in a human glioblastoma chicken chorioallantoic membrane model: a new tool for oncology and radiotracer development.

    PubMed

    Warnock, Geoff; Turtoi, Andrei; Blomme, Arnaud; Bretin, Florian; Bahri, Mohamed Ali; Lemaire, Christian; Libert, Lionel Cyrille; Seret, Alain E J J; Luxen, André; Castronovo, Vincenzo; Plenevaux, Alain R E G

    2013-10-01

    For many years the laboratory mouse has been used as the standard model for in vivo oncology research, particularly in the development of novel PET tracers, but the growth of tumors on chicken chorioallantoic membrane (CAM) provides a more rapid, low cost, and ethically sustainable alternative. For the first time, to our knowledge, we demonstrate the feasibility of in vivo PET and CT imaging in a U87 glioblastoma tumor model on chicken CAM, with the aim of applying this model for screening of novel PET tracers. U87 glioblastoma cells were implanted on the CAM at day 11 after fertilization and imaged at day 18. A small-animal imaging cell was used to maintain incubation and allow anesthesia using isoflurane. Radiotracers were injected directly into the exposed CAM vasculature. Sodium (18)F-fluoride was used to validate the imaging protocol, demonstrating that image-degrading motion can be removed with anesthesia. Tumor glucose metabolism was imaged using (18)F-FDG, and tumor protein synthesis was imaged using 2-(18)F-fluoro-l-tyrosine. Anatomic images were obtained by contrast-enhanced CT, facilitating clear delineation of the tumor, delineation of tracer uptake in tumor versus embryo, and accurate volume measurements. PET imaging of tumor glucose metabolism and protein synthesis was successfully demonstrated in the CAM U87 glioblastoma model. Catheterization of CAM blood vessels facilitated dynamic imaging of glucose metabolism with (18)F-FDG and demonstrated the ability to study PET tracer uptake over time in individual tumors, and CT imaging improved the accuracy of tumor volume measurements. We describe the novel application of PET/CT in the CAM tumor model, with optimization of typical imaging protocols. PET imaging in this valuable tumor model could prove particularly useful for rapid, high-throughput screening of novel radiotracers.

  14. Investigation of the Binding Profiles of AZD2184 and Thioflavin T with Amyloid-β(1-42) Fibril by Molecular Docking and Molecular Dynamics Methods.

    PubMed

    Kuang, Guanglin; Murugan, N Arul; Tu, Yaoquan; Nordberg, Agneta; Ågren, Hans

    2015-09-03

    Detecting deposits of amyloid β fibrils in the brain is of paramount importance for an early diagnosis of Alzheimer's disease. A number of PET tracers have been developed for amyloid imaging, but many suffer from poor specificity and large signal to background ratio. Design of tracers with specificity and improved binding affinity requires knowledge about various potential binding sites in the amyloid β fibril available for the tracers and the nature of the local microenvironment of these sites. In this study we investigate the local structure of fibrils using two important probes, namely, thioflavin T (a fluorescent probe) and AZD2184 (a PET tracer). The target structures for amyloid-β(1-42) fibril are based on reported NMR solution models. By explicitly considering the effect of fibril flexibility on the available binding sites for all these models, the binding affinity of these probes has been investigated. The binding profiles of AZD2184 and thioflavin T were studied by molecular docking and molecular dynamics simulation methods. The two compounds were found to bind at the same sites of the fibril: three of which are within the fibril, and one is on the two sides of the Met35 residue on the surface. The binding affinity of AZD2184 and thioflavin T is found to be higher at the core sites than on the surface due to more contact residues. The binding affinity of AZD2184 is much higher than that of thioflavin T at every site due to electrostatic interaction and spatial restriction, which is in good agreement with experimental observation. However, the structural change of thioflavin T is much more significant than that of AZD2184, which is the chemical basis for its usage as a fluorescent probe. The ramifications of these results for the design and optimization of PET radioligands and fluorescent probes are briefly discussed.

  15. Stratospheric Assimilation of Chemical Tracer Observations Using a Kalman Filter. Pt. 2; Chi-Square Validated Results and Analysis of Variance and Correlation Dynamics

    NASA Technical Reports Server (NTRS)

    Menard, Richard; Chang, Lang-Ping

    1998-01-01

    A Kalman filter system designed for the assimilation of limb-sounding observations of stratospheric chemical tracers, which has four tunable covariance parameters, was developed in Part I (Menard et al. 1998) The assimilation results of CH4 observations from the Cryogenic Limb Array Etalon Sounder instrument (CLAES) and the Halogen Observation Experiment instrument (HALOE) on board of the Upper Atmosphere Research Satellite are described in this paper. A robust (chi)(sup 2) criterion, which provides a statistical validation of the forecast and observational error covariances, was used to estimate the tunable variance parameters of the system. In particular, an estimate of the model error variance was obtained. The effect of model error on the forecast error variance became critical after only three days of assimilation of CLAES observations, although it took 14 days of forecast to double the initial error variance. We further found that the model error due to numerical discretization as arising in the standard Kalman filter algorithm, is comparable in size to the physical model error due to wind and transport modeling errors together. Separate assimilations of CLAES and HALOE observations were compared to validate the state estimate away from the observed locations. A wave-breaking event that took place several thousands of kilometers away from the HALOE observation locations was well captured by the Kalman filter due to highly anisotropic forecast error correlations. The forecast error correlation in the assimilation of the CLAES observations was found to have a structure similar to that in pure forecast mode except for smaller length scales. Finally, we have conducted an analysis of the variance and correlation dynamics to determine their relative importance in chemical tracer assimilation problems. Results show that the optimality of a tracer assimilation system depends, for the most part, on having flow-dependent error correlation rather than on evolving the error variance.

  16. Uncertainties in assessing tillage erosion - How appropriate are our measuring techniques?

    NASA Astrophysics Data System (ADS)

    Fiener, P.; Wilken, F.; Aldana-Jague, E.; Deumlich, D.; Gómez, J. A.; Guzmán, G.; Hardy, R. A.; Quinton, J. N.; Sommer, M.; Van Oost, K.; Wexler, R.

    2018-03-01

    Tillage erosion on arable land is a very important process leading to a net downslope movement of soil and soil constitutes. Tillage erosion rates are commonly in the same order of magnitude as water erosion rates and can be even higher, especially under highly mechanized agricultural soil management. Despite its prevalence and magnitude, tillage erosion is still understudied compared to water erosion. The goal of this study was to bring together experts using different techniques to determine tillage erosion and use the different results to discuss and quantify uncertainties associated with tillage erosion measurements. The study was performed in northeastern Germany on a 10 m by 50 m plot with a mean slope of 8%. Tillage erosion was determined after two sequences of seven tillage operations. Two different micro-tracers (magnetic iron oxide mixed with soil and fluorescent sand) and one macro-tracer (passive radio-frequency identification transponders (RFIDs), size: 4 × 22 mm) were used to directly determine soil fluxes. Moreover, tillage induced changes in topography were measured for the entire plot with two different terrestrial laser scanners and an unmanned aerial system for structure from motion topography analysis. Based on these elevation differences, corresponding soil fluxes were calculated. The mean translocation distance of all techniques was 0.57 m per tillage pass, with a relatively wide range of mean soil translocation distances ranging from 0.39 to 0.72 m per pass. A benchmark technique could not be identified as all used techniques have individual error sources, which could not be quantified. However, the translocation distances of the macro-tracers used were consistently smaller than the translocation distances of the micro-tracers (mean difference = - 26 ± 12%), which questions the widely used assumption of non-selective soil transport via tillage operations. This study points out that tillage erosion measurements, carried out under almost optimal conditions, are subject to major uncertainties that are far from negligible.

  17. A DNA Tracer System for Hydrological Environment Investigations.

    PubMed

    Liao, Renkuan; Yang, Peiling; Wu, Wenyong; Luo, Dan; Yang, Dayong

    2018-02-20

    To monitor and manage hydrological pollution effectively, tracing sources of pollutants is of great importance and also is in urgent need. A variety of tracers have been developed such as isotopes, silica, bromide, and dyes; however, practical limitations of these traditional tracers still exist such as lack of multiplexed, multipoint tracing and interference of background noise. To overcome these limitations, a new tracing system based on DNA nanomaterials, namely DNA tracer, has already been developed. DNA tracers possess remarkable advantages including sufficient species, specificity, environmental friendly, stable migration, and high sensitivity as well as allowing for multipoints tracing. In this review article, we introduce the molecular design, synthesis, protection and signal readout strategies of DNA tracers, compare the advantages and disadvantages of DNA tracer with traditional tracers, and summarize the-state-of-art applications in hydrological environment investigations. In the end, we provide our perspective on the future development of DNA tracers.

  18. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    USGS Publications Warehouse

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.

  19. Tracking groundwater discharge to a large river using tracers and geophysics.

    PubMed

    Harrington, Glenn A; Gardner, W Payton; Munday, Tim J

    2014-01-01

    Few studies have investigated large reaches of rivers in which multiple sources of groundwater are responsible for maintaining baseflow. This paper builds upon previous work undertaken along the Fitzroy River, one of the largest perennial river systems in north-western Australia. Synoptic regional-scale sampling of both river water and groundwater for a suite of environmental tracers ((4) He, (87) Sr/(86) Sr, (222) Rn and major ions), and subsequent modeling of tracer behavior in the river, has enabled definition and quantification of groundwater input from at least three different sources. We show unambiguous evidence of both shallow "local" groundwater, possibly recharged to alluvial aquifers beneath the adjacent floodplain during recent high-flow events, and old "regional" groundwater introduced via artesian flow from deep confined aquifers. We also invoke hyporheic exchange and either bank return flow or parafluvial flow to account for background (222) Rn activities and anomalous chloride trends along river reaches where there is no evidence of the local or regional groundwater inputs. Vertical conductivity sections acquired through an airborne electromagnetic (AEM) survey provide insights to the architecture of the aquifers associated with these sources and general groundwater quality characteristics. These data indicate fresh groundwater from about 300 m below ground preferentially discharging to the river, at locations consistent with those inferred from tracer data. The results demonstrate how sampling rivers for multiple environmental tracers of different types-including stable and radioactive isotopes, dissolved gases and major ions-can significantly improve conceptualization of groundwater-surface water interaction processes, particularly when coupled with geophysical techniques in complex hydrogeological settings. © 2013, National Ground Water Association.

  20. Improving Estimation of Submarine Groundwater Discharge Using Radium and Radon Tracers: Application in Jiaozhou Bay, China

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Li, Hailong; Xiao, Kai; Wang, Xuejing; Lu, Xiaoting; Zhang, Meng; An, An; Qu, Wenjing; Wan, Li; Zheng, Chunmiao; Wang, Xusheng; Jiang, Xiaowei

    2017-10-01

    Radium and radon mass balance models have been widely used to quantify submarine groundwater discharge (SGD) in the coastal areas. However, the losses of radium or radon in seawater caused by recirculated saline groundwater discharge (RSGD) are ignored in most of the previous studies for tracer-based models and this can lead to an underestimation of SGD. Here we present an improved method which considers the losses of tracers caused by RSGD to enhance accuracy in estimating SGD and SGD-associated material loadings. Theoretical analysis indicates that neglecting the losses of tracers induced by RSGD would underestimate the SGD by a percentage approximately equaling the tracer activity ratio of nearshore seawater to groundwater. The data analysis of previous typical case studies shows that the existing old models underestimated the SGD by 1.9-93%, with an average of 32.2%. The method is applied in Jiaozhou Bay (JZB), North China, which is experiencing significant environmental pollution. The SGD flux into JZB estimated by the improved method is ˜1.44 and 1.34 times of that estimated by the old method for 226Ra mass balance model and 228Ra mass balance model, respectively. Both SGD and RSGD fluxes are significantly higher than the discharge rate of Dagu River (the largest one running into JZB). The fluxes of nutrients and metals through SGD are comparable to or even higher than those from local rivers, which indicates that SGD is an important source of chemicals into JZB and has important impact on marine ecological system.

  1. A 3-D hydrologic transport model of a water recharge system using carbamazepine and chloride as tracers

    NASA Astrophysics Data System (ADS)

    Rona, Michael; Gasser, Guy; Negev, Ido; Pankratov, Irena; Elhanany, Sara; Lev, Ovadia; Gvirtzman, Haim

    2014-05-01

    Wastewater recharge facilities are often used as a final water treatment before the discharge to the sea or before water reclamation. These facilities are often located in active aquifers that supply drinking water. Thus, leakage from the water recharge facility and gradual expansion of the underground wastewater plume are of considerable health concern. Hydrological modeling of water recharge systems are widely used as operational and predictive tools. These models rely on distributed water head monitoring and at least one chemical or physical tracer to model solutes' transport. Refractory micropollutants have proven useful in qualitative identification of pollution leakages and for quantification of pollution to a specific site near water recharge facilities. However, their usefulness as tracers for hydrological modeling is still questionable. In this article, we describe a long term, 3-D hydraulic model of a large-scale wastewater effluents recharge system in which a combination of chloride and a refractory micropollutant, carbamazepine is used to trace the solute transport. The combination of the two tracers provides the model with the benefits of the high specificity of the carbamazepine and the extensive historic data base that is available for chloride. The model predicts westward expansion of the pollution plume, whereas a standing front is formed at the east. These trends can be confirmed by the time trace of the carbamazepine concentrations at specific locations. We show that the combination of two tracers accounts better (at least at some locations) for the evolution of the pollution plume than a model based on chloride or carbamazepine alone.

  2. Quantifying postfire aeolian sediment transport using rare earth element tracers

    USGS Publications Warehouse

    Dukes, David; Gonzales, Howell B.; Ravi, Sujith; Grandstaff, David E.; Van Pelt, R. Scott; Li, Junran; Wang, Guan; Sankey, Joel B.

    2018-01-01

    Grasslands, which provide fundamental ecosystem services in many arid and semiarid regions of the world, are undergoing rapid increases in fire activity and are highly susceptible to postfire-accelerated soil erosion by wind. A quantitative assessment of physical processes that integrates fire-wind erosion feedbacks is therefore needed relative to vegetation change, soil biogeochemical cycling, air quality, and landscape evolution. We investigated the applicability of a novel tracer technique—the use of multiple rare earth elements (REE)—to quantify soil transport by wind and to identify sources and sinks of wind-blown sediments in both burned and unburned shrub-grass transition zone in the Chihuahuan Desert, NM, USA. Results indicate that the horizontal mass flux of wind-borne sediment increased approximately threefold following the fire. The REE tracer analysis of wind-borne sediments shows that the source of the horizontal mass flux in the unburned site was derived from bare microsites (88.5%), while in the burned site it was primarily sourced from shrub (42.3%) and bare (39.1%) microsites. Vegetated microsites which were predominantly sinks of aeolian sediments in the unburned areas became sediment sources following the fire. The burned areas showed a spatial homogenization of sediment tracers, highlighting a potential negative feedback on landscape heterogeneity induced by shrub encroachment into grasslands. Though fires are known to increase aeolian sediment transport, accompanying changes in the sources and sinks of wind-borne sediments may influence biogeochemical cycling and land degradation dynamics. Furthermore, our experiment demonstrated that REEs can be used as reliable tracers for field-scale aeolian studies.

  3. Identification of a Novel Indoline Derivative for in Vivo Fluorescent Imaging of Blood-Brain Barrier Disruption in Animal Models

    PubMed Central

    2013-01-01

    Disruption of the blood-brain barrier (BBB) can occur in various pathophysiological conditions. Administration of extraneous tracers that can pass the disrupted, but not the intact, BBB and detection of the extravasation have been widely used to assess BBB disruption in animal models. Although several fluorescent tracers have been successfully used, the administration of these tracers basically requires intravascular injection, which can be laborious when using small animals such as zebrafish. To identify fluorescent tracers that could be easily administered into various animal models and visualize the BBB disruption in vivo, we prepared nine structurally related indoline derivatives (IDs) as a minimum set of diverse fluorescent compounds. We found that one ID, ZMB741, had the highest affinity for serum albumin and emitted the strongest fluorescence in the presence of serum albumin of the nine IDs tested. The affinity to serum albumin and the fluorescence intensity was superior to those of Evans blue and indocyanine green that have been conventionally used to assess the BBB disruption. We showed that ZMB741 could be administered into zebrafish by static immersion or mice by intraperitoneal injection and visualizes the active disruption of their BBB. These results suggest that ZMB741 can be a convenient and versatile tool for in vivo fluorescent imaging of BBB disruption in various animal models. The strategy used in this study can also be applied to diversity-oriented libraries to identify novel fluorescent tracers that may be superior to ZMB741. PMID:23668665

  4. Perfluorocarbon background concentrations in Europe

    NASA Astrophysics Data System (ADS)

    Straume, Anne Grete; Dietz, Russel N.; Koffı̀, Ernest N.'dri; Nodop, Katrin

    Five studies of the background level of several perfluorocarbon compounds in Europe are here presented together with measurements from the European Tracer Experiment (ETEX). The tracers used during the two ETEX tracer releases were the perfluorocarbons (PFCs); perfluoromethylcyclohexane (C 7F 14, PMCH) and perfluoromethylcyclopentane (C 6F 12, PMCP). Their background concentrations were detected by using both passive and active sampling techniques, to define the spatial and temporal variation of the PFCs over Europe. Also the background variations of four isomers of the PFC compound perfluorodimethylcyclohexane (C 8F 16, PDCH) were studied. The results were compared to other PFC tracer studies in the U.S.A. and Europe. The mean and median values of the measured PFCs were found to vary slightly and randomly in space and time. They were found to be higher and to have a larger standard deviation than the measurements from the American studies. The background concentrations were still found to be low and stable enough for PFCs to be highly suitable for use in tracer studies. The following concentrations were found: PMCP; 4.6±0.3 fl ℓ -1, PMCH: 4.6±0.8 fl ℓ -1, ocPDCH: 0.96±0.33 fl ℓ -1, mtPDCH: 9.3±0.8 fl ℓ -1, mcPDCH: 8.8±0.8 fl ℓ -1, ptPDCH: 6.1±0.8 fl ℓ -1. A study of the correlation between the measured PFC compounds showed a significant correlation between most of the compounds, which indicate that there are no major PFC sources in Europe.

  5. Direct Parametric Image Reconstruction in Reduced Parameter Space for Rapid Multi-Tracer PET Imaging.

    PubMed

    Cheng, Xiaoyin; Li, Zhoulei; Liu, Zhen; Navab, Nassir; Huang, Sung-Cheng; Keller, Ulrich; Ziegler, Sibylle; Shi, Kuangyu

    2015-02-12

    The separation of multiple PET tracers within an overlapping scan based on intrinsic differences of tracer pharmacokinetics is challenging, due to limited signal-to-noise ratio (SNR) of PET measurements and high complexity of fitting models. In this study, we developed a direct parametric image reconstruction (DPIR) method for estimating kinetic parameters and recovering single tracer information from rapid multi-tracer PET measurements. This is achieved by integrating a multi-tracer model in a reduced parameter space (RPS) into dynamic image reconstruction. This new RPS model is reformulated from an existing multi-tracer model and contains fewer parameters for kinetic fitting. Ordered-subsets expectation-maximization (OSEM) was employed to approximate log-likelihood function with respect to kinetic parameters. To incorporate the multi-tracer model, an iterative weighted nonlinear least square (WNLS) method was employed. The proposed multi-tracer DPIR (MTDPIR) algorithm was evaluated on dual-tracer PET simulations ([18F]FDG and [11C]MET) as well as on preclinical PET measurements ([18F]FLT and [18F]FDG). The performance of the proposed algorithm was compared to the indirect parameter estimation method with the original dual-tracer model. The respective contributions of the RPS technique and the DPIR method to the performance of the new algorithm were analyzed in detail. For the preclinical evaluation, the tracer separation results were compared with single [18F]FDG scans of the same subjects measured 2 days before the dual-tracer scan. The results of the simulation and preclinical studies demonstrate that the proposed MT-DPIR method can improve the separation of multiple tracers for PET image quantification and kinetic parameter estimations.

  6. Evaluation of rapid dual-tracer 62Cu-PTSM + 62Cu-ATSM PET in dogs with spontaneously occurring tumors

    NASA Astrophysics Data System (ADS)

    Black, Noel F.; McJames, Scott; Rust, Thomas C.; Kadrmas, Dan J.

    2008-01-01

    We are developing methods for imaging multiple PET tracers in a single scan with staggered injections, where imaging measures for each tracer are separated and recovered using differences in tracer kinetics and radioactive decay. In this work, signal separation performance for rapid dual-tracer 62Cu-PTSM (blood flow) + 62Cu-ATSM (hypoxia) tumor imaging was evaluated in a large animal model. Four dogs with pre-existing tumors received a series of dynamic PET scans with 62Cu-PTSM and 62Cu-ATSM, permitting evaluation of a rapid dual-tracer protocol designed by previous simulation work. Several imaging measures were computed from the dual-tracer data and compared with those from separate, single-tracer imaging. Static imaging measures (e.g. SUV) for each tracer were accurately recovered from dual-tracer data. The wash-in (k1) and wash-out (k2) rate parameters for both tracers were likewise well recovered (r = 0.87-0.99), but k3 was not accurately recovered for PTSM (r = 0.19) and moderately well recovered for ATSM (r = 0.70). Some degree of bias was noted, however, which may potentially be overcome through further refinement of the signal separation algorithms. This work demonstrates that complementary information regarding tumor blood flow and hypoxia can be acquired by a single dual-tracer PET scan, and also that the signal separation procedure works effectively for real physiologic data with realistic levels of kinetic model mismatch. Rapid multi-tracer PET has the potential to improve tumor assessment for image-guide therapy and monitoring, and further investigation with these and other tracers is warranted.

  7. Evaluation of Rapid Dual-Tracer 62Cu-PTSM + 62Cu-ATSM PET in Dogs with Spontaneously-Occurring Tumors

    PubMed Central

    Black, Noel F.; McJames, Scott; Rust, Thomas C.; Kadrmas, Dan J.

    2013-01-01

    We are developing methods for imaging multiple PET tracers in a single scan with staggered injections, where imaging measures for each tracer are separated and recovered using differences in tracer kinetics and radioactive decay. In this work, signal-separation performance for rapid dual-tracer 62Cu-PTSM (blood flow) + 62Cu-ATSM (hypoxia) tumor imaging was evaluated in a large animal model. Four dogs with pre-existing tumors received a series of dynamic PET scans with 62Cu-PTSM and 62Cu-ATSM, permitting evaluation of a rapid dual-tracer protocol designed by previous simulation work. Several imaging measures were computed from the dual-tracer data and compared with those from separate, single-tracer imaging. Static imaging measures (e.g. SUV) for each tracer were accurately recovered from dual-tracer data. The wash-in (k1) and wash-out (k2) rate parameters for both tracers were likewise well recovered (r = 0.87 – 0.99), but k3 was not accurately recovered for PTSM (r = 0.19) and moderately well recovered for ATSM (r = 0.70). Some degree of bias was noted, however, which may potentially be overcome through further refinement of the signal-separation algorithms. This work demonstrates that complementary information regarding tumor blood flow and hypoxia can be acquired by a single dual-tracer PET scan, and also that the signal-separation procedure works effectively for real physiologic data with realistic levels of kinetic model-mismatch. Rapid multi-tracer PET has the potential to improve tumor assessment for image-guide therapy and monitoring, and further investigation with these and other tracers is warranted. PMID:18182698

  8. Pharmaceuticals as Groundwater Tracers - Applications and Limitations

    NASA Astrophysics Data System (ADS)

    Scheytt, T. J.; Mersmann, P.; Heberer, T.

    2003-12-01

    Pharmaceutically active substances and metabolites are found at concentrations up to the microgram/L-level in groundwater samples from the Berlin (Germany) area and from several other places world wide. Among the compounds detected in groundwater are clofibric acid, propyphenazone, diclofenac, ibuprofen, and carbamazepine. Clofibric acid, the active metabolite of clofibrate and etofibrate (blood lipid regulators) is detected in groundwater at maximum concentrations of 7300 ng/L. Among the most important input paths of drugs are excretion and disposal into the sewage system. Groundwater contamination is likely to be due to leaky sewage systems, influent streams, bank filtration, and irrigation with effluent water from sewage treatment plants. There are no known natural sources of the above mentioned pharmaceuticals. The use of pharmaceuticals as tracers may include: (a) Quantification of infiltration from underground septic tanks (b) Detection of leaky sewage systems / leaky sewage pipes (c) Estimation of the effectiveness of sewage treatment plants (d) Identification of transport pathways of other organic compounds (e) Quantification of surface water / groundwater interaction (f) Characterization of the biodegradation potential. The use of pharmaceuticals as tracers is limited by variations in input. These variations depend on the amount of drugs prescribed and used in the study area, the social structure of the community, the amount of hospital discharge, and temporal concentration variations. Furthermore, the analysis of trace amounts of pharmaceuticals is sophisticated and expensive and may therefore limit the applicability of pharmaceuticals as tracers. Finally, the transport and degradation behavior of pharmaceuticals is not fully understood. Preliminary experiments in the laboratory were conducted using sediment material and groundwater from the Berlin area to evaluate the transport and sorption behavior of selected drugs. Results of the column experiments show that clofibric acid exhibits no degradation and almost no retardation (Rf = 1.1) whereas ibuprofen is biodegraded (> 90 %) under aerobic conditions. Carbamazepine shows no degradation in the soil column experiments but significant retardation under the prevailing conditions. We conclude that clofibric acid will show the transport behavior of a conservative tracer, whereas ibuprofen may be used to characterize the biodegradation potential in the aerobic zone.

  9. In VIVO tracer kinetics of plant function using positron emission technology

    NASA Astrophysics Data System (ADS)

    Fares, Y.; Goeschl, J. D.; Magnuson, C. E.; Mckinney, C. J.; Musser, R. L.; Strain, B. R.

    1989-04-01

    A 11CO 2 storage and dispensing system was developed and used successfully to deliver constant activity levels for 2 h plant tracer experiments. Using tracer kinetics of a step input function the relationships between diurnal patterns of carbon partitioning and gas exchange properties of leaves in C 3 and C 4 plants were studied. We also studied the immediate and long term effects of the abrupt changes in CO 2 concentrations on carbon partitioning of these species. Results indicate that raising the CO 2 concentration above ambient immediately increases 11C storage over export rates, while lowering the CO 2 concentration immediately decreases storage more than export rates. This long term accumulation of starch may depend as much on the biochemistry of partitioning within the leaf as on limitations in the sink capacity of plants. Although gas exchange remained constant during the photoperiod, the photosynthate storage rate increased and the export rate decreased. These changes were more pronounced in C 4 plants.

  10. Catalytically powered dynamic assembly of rod-shaped nanomotors and passive tracer particles

    PubMed Central

    Wang, Wei; Duan, Wentao; Sen, Ayusman; Mallouk, Thomas E.

    2013-01-01

    Nano- and microscale motors powered by catalytic reactions exhibit collective behavior such as swarming, predator–prey interactions, and chemotaxis that resemble those of biological microorganisms. A quantitative understanding of the catalytically generated forces between particles that lead to these behaviors has so far been lacking. Observations and numerical simulations of pairwise interactions between gold-platinum nanorods in hydrogen peroxide solutions show that attractive and repulsive interactions arise from the catalytically generated electric field. Electrokinetic effects drive the assembly of staggered doublets and triplets of nanorods that are moving in the same direction. None of these behaviors are observed with nanorods composed of a single metal. The motors also collect tracer microparticles at their head or tail, depending on the charge of the particles, actively assembling them into close-packed rafts and aggregates of rafts. These motor–tracer particle interactions can also be understood in terms of the catalytically generated electric field around the ends of the nanorod motors. PMID:24127603

  11. Catalytically powered dynamic assembly of rod-shaped nanomotors and passive tracer particles.

    PubMed

    Wang, Wei; Duan, Wentao; Sen, Ayusman; Mallouk, Thomas E

    2013-10-29

    Nano- and microscale motors powered by catalytic reactions exhibit collective behavior such as swarming, predator-prey interactions, and chemotaxis that resemble those of biological microorganisms. A quantitative understanding of the catalytically generated forces between particles that lead to these behaviors has so far been lacking. Observations and numerical simulations of pairwise interactions between gold-platinum nanorods in hydrogen peroxide solutions show that attractive and repulsive interactions arise from the catalytically generated electric field. Electrokinetic effects drive the assembly of staggered doublets and triplets of nanorods that are moving in the same direction. None of these behaviors are observed with nanorods composed of a single metal. The motors also collect tracer microparticles at their head or tail, depending on the charge of the particles, actively assembling them into close-packed rafts and aggregates of rafts. These motor-tracer particle interactions can also be understood in terms of the catalytically generated electric field around the ends of the nanorod motors.

  12. Simulation of nonylphenol degradation in leafy vegetables using a deuterated tracer.

    PubMed

    Fang, Kun; Jiang, Zejun; Wang, Jing; She, Yongxin; Jin, Maojun; Jin, Fen; Yang, Mao

    2015-07-01

    In this study, the residues of nonylphenol, an endocrine-disrupting chemical, were investigated in two types of leafy vegetables, leek and cabbage, that are commonly consumed in eight provinces in China. Nonylphenol was detected in 43.50% of the 223 samples, at concentrations up to 51.90 μg kg(-1). The isotopic tracer 4-n-NP-2,3,5,6-d4-OD was chosen to simulate the degradation of nonylphenol in cabbage. More than 80% of the tracer was degraded in the first 7 days, and most of it had vanished by the end of the 35-day experimental period. A preliminary degradation equation was established to describe the variation of nonylphenol residues in leafy vegetables, and the amounts of nonylphenol in four pesticides were analyzed. The results indicated that nonylphenol residues in leafy vegetables are probably derived from the applied pesticides. The potential risk of pesticide adjuvants as well as that of the active ingredient in pesticides should be taken into consideration when recommending a safety interval period.

  13. Leakage detection of Marcellus Shale natural gas at an Upper Devonian gas monitoring well: a 3-d numerical modeling approach.

    PubMed

    Zhang, Liwei; Anderson, Nicole; Dilmore, Robert; Soeder, Daniel J; Bromhal, Grant

    2014-09-16

    Potential natural gas leakage into shallow, overlying formations and aquifers from Marcellus Shale gas drilling operations is a public concern. However, before natural gas could reach underground sources of drinking water (USDW), it must pass through several geologic formations. Tracer and pressure monitoring in formations overlying the Marcellus could help detect natural gas leakage at hydraulic fracturing sites before it reaches USDW. In this study, a numerical simulation code (TOUGH 2) was used to investigate the potential for detecting leaking natural gas in such an overlying geologic formation. The modeled zone was based on a gas field in Greene County, Pennsylvania, undergoing production activities. The model assumed, hypothetically, that methane (CH4), the primary component of natural gas, with some tracer, was leaking around an existing well between the Marcellus Shale and the shallower and lower-pressure Bradford Formation. The leaky well was located 170 m away from a monitoring well, in the Bradford Formation. A simulation study was performed to determine how quickly the tracer monitoring could detect a leak of a known size. Using some typical parameters for the Bradford Formation, model results showed that a detectable tracer volume fraction of 2.0 × 10(-15) would be noted at the monitoring well in 9.8 years. The most rapid detection of tracer for the leak rates simulated was 81 days, but this scenario required that the leakage release point was at the same depth as the perforation zone of the monitoring well and the zones above and below the perforation zone had low permeability, which created a preferred tracer migration pathway along the perforation zone. Sensitivity analysis indicated that the time needed to detect CH4 leakage at the monitoring well was very sensitive to changes in the thickness of the high-permeability zone, CH4 leaking rate, and production rate of the monitoring well.

  14. Assessing Glomerular Filtration in Small Animals Using [68Ga]DTPA and [68Ga]EDTA with PET Imaging.

    PubMed

    Gündel, Daniel; Pohle, Ulrike; Prell, Erik; Odparlik, Andreas; Thews, Oliver

    2018-06-01

    Determining the glomerular filtration rate (GFR) is essential for clinical medicine but also for pre-clinical animal studies. Functional imaging using positron emission tomography (PET) allows repetitive almost non-invasive measurements. The aim of the study was the development and evaluation of easily synthesizable PET tracers for GFR measurements in small animals. Diethylenetriaminepentaacetic acid (DTPA) and ethylenediaminetetraacetic acid (EDTA) were labeled with Ga-68. The binding to blood cells and plasma proteins was tested in vitro. The distribution of the tracers in rats was analyzed by PET imaging and ex vivo measurements. From the time-activity-curve of the blood compartment (heart) and the total tracer mass excreted by the kidney, the GFR was calculated. These values were compared directly with the inulin clearance in the same animals. Both tracers did not bind to blood cells. [ 68 Ga]DPTA but not [ 68 Ga]EDTA showed strong binding to plasma proteins. For this reason, [ 68 Ga]DPTA stayed much longer in the blood and only 30 % of the injected dose was eliminated by the kidney within 60 min whereas the excretion of [ 68 Ga]EDTA was 89 ± 1 %. The calculated GFR using [ 68 Ga]EDTA was comparable to the measured inulin clearance in the same animal. Using [ 68 Ga]-DPTA, the measurements led to values which were 80 % below the normal GFR. The results also revealed that definition of the volume of interest for the blood compartment affects the calculation and may lead to a slight overestimation of the GFR. [ 68 Ga]EDTA is a suitable tracer for GFR calculation from PET imaging in small animals. It is easy to be labeled, and the results are in good accordance with the inulin clearance. [ 68 Ga]DTPA led to a marked underestimation of GFR due to its strong binding to plasma proteins and is therefore not an appropriate tracer for GFR measurements.

  15. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  16. Utilizing Tritium and CFC-12 to Determine Groundwater Sources in an Unconfined Aquifer Within the Abalone Cove Landslide, Palos Verdes, California

    NASA Astrophysics Data System (ADS)

    Difilippo, E. L.; Hammond, D. E.; Douglas, R.; Clark, J. F.; Avisar, D.; Dunker, R.

    2004-12-01

    The Abalone Cove landslide occupies 80 acres of an ancient landslide complex on the Palos Verdes peninsula, and was re-activated in 1979. The uphill portion of the ancient landslide complex has remained stable in historic times. Water infiltration into the slide is a short term catalyst for mass movement in the area, so it is important to determine the sources of groundwater throughout the slide mass. Water may enter the slide mass through direct percolation of recent precipitation, inflow along the head scarp of the ancient landslide or by rising through the slide plane from a deeper aquifer. The objective of this contribution is to use geochemical tracers (tritium and CFC-12) in combination with numerical modeling to constrain the importance of each of these sources. Numerical models were constructed to predict geochemical tracer concentrations throughout the basin, assuming that the only source of water to the slide mass is percolation of recent precipitation. Predicted concentrations were then compared to measured tracer values. In the ancient landslide, predicted and measured tracer concentrations are in good agreement, indicating that most of the water in this area is recent precipitation falling within the basin. Groundwater recharged uphill of the ancient landslide contributes minor flow into the complex through the head scarp, with the majority of this water flowing beneath the ancient slide plane. However, predicted tracer concentrations in the toe of the Abalone Cove landslide are not consistent with measured values. Both CFC-12 and tritium concentrations indicate that water is older than predicted and communication between the slide mass and the aquifer beneath the slide plane must occur in this area. Infiltration of this deep circulating water may exert upward hydraulic pressure on the landslide slip surface, increasing the potential for movement. This hypothesis is consistent with the observation that current movement is only occurring in the area in which tracers indicate communication with the deeper aquifer.

  17. Simultaneous measurement of ventilation using tracer gas techniques and VOC concentrations in homes, garages and vehicles.

    PubMed

    Batterman, Stuart; Jia, Chunrong; Hatzivasilis, Gina; Godwin, Chris

    2006-02-01

    Air exchange rates and interzonal flows are critical ventilation parameters that affect thermal comfort, air migration, and contaminant exposure in buildings and other environments. This paper presents the development of an updated approach to measure these parameters using perfluorocarbon tracer (PFT) gases, the constant injection rate method, and adsorbent-based sampling of PFT concentrations. The design of miniature PFT sources using hexafluorotoluene and octafluorobenzene tracers, and the development and validation of an analytical GC/MS method for these tracers are described. We show that simultaneous deployment of sources and passive samplers, which is logistically advantageous, will not cause significant errors over multiday measurement periods in building, or over shorter periods in rapidly ventilated spaces like vehicle cabins. Measurement of the tracers over periods of hours to a week may be accomplished using active or passive samplers, and low method detection limits (<0.025 microg m(-3)) and high precisions (<10%) are easily achieved. The method obtains the effective air exchange rate (AER), which is relevant to characterizing long-term exposures, especially when ventilation rates are time-varying. In addition to measuring the PFT tracers, concentrations of other volatile organic compounds (VOCs) are simultaneously determined. Pilot tests in three environments (residence, garage, and vehicle cabin) demonstrate the utility of the method. The 4 day effective AER in the house was 0.20 h(-1), the 4 day AER in the attached garage was 0.80 h(-1), and 16% of the ventilation in the house migrated from the garage. The 5 h AER in a vehicle traveling at 100 km h(-1) under a low-to-medium vent condition was 92 h(-1), and this represents the highest speed test found in the literature. The method is attractive in that it simultaneously determines AERs, interzonal flows, and VOC concentrations over long and representative test periods. These measurements are practical, cost-effective, and helpful in indoor air quality and other investigations.

  18. Exploring Microbial Processes with Thermal-Hydrological Models of the Eastern Flank of the Juan de Fuca Ridge

    NASA Astrophysics Data System (ADS)

    Weathers, T. S.; Fisher, A. T.; Winslow, D. M.; Stauffer, P. H.; Gable, C. W.

    2017-12-01

    The flanks of mid-ocean ridges experience coupled flows of fluid, heat, and solutes that are critical for a wide range of global processes, including the cycling of carbon and nutrients, which supports a vast crustal biosphere. Only a few ridge-flank sites have been studied in detail; hydrogeologic conditions and processes in the volcanic crust are best understood on the eastern flank of the Juan de Fuca Ridge. This area has been extensively explored with decades of drilling, submersible, observatory, and survey expeditions and experiments, including the first hole-to-hole tracer injection experiment in the ocean crust. This study describes the development of reactive transport simulations for this ridge-flank setting using three-dimensional coupled (thermal-hydrological) models of crustal-scale circulation, beginning with the exploration of tracer transport. The prevailing flow direction is roughly south to north as a result of outcrop-to-outcrop flow, with a bulk flow rate in the range of meters/year. However, tracer was detected 500 m south ("upstream") from the injection borehole during the first year following injection. This may be explained by local mixing and/or formation fluid discharge from the southern borehole during and after injection. The constraints and parameters required to fit the observed tracer behavior can be used as a basis for modeling reactive transport processes such as nutrient delivery or microbial community evolution as a function of fluid flow. For example, the sulfate concentration in fluid samples from Baby Bare outcrop ( 8 km south of the tracer transport experiment) was 17.8 mmol/kg, whereas at Mama Bare outcrop ( 8 km to north of the tracer transport experiment) the sulfate concentration was 16.3 mmol/mg. By integrating laboratory-derived sulfate reduction rates from microbial samples originating from Juan de Fuca borehole observatories into reactive transport models, we can explore the range of microbial activity that supports the observed concentration gradients of sulfate and other solutes in the volcanic ocean crust.

  19. Measuring and Visualizing Students' Behavioral Engagement in Writing Activities

    ERIC Educational Resources Information Center

    Liu, Ming; Calvo, Rafael A.; Pardo, Abelardo; Martin, Andrew

    2015-01-01

    Engagement is critical to the success of learning activities such as writing, and can be promoted with appropriate feedback. Current engagement measures rely mostly on data collected by observers or self-reported by the participants. In this paper, we describe a learning analytic system called Tracer, which derives behavioral engagement measures…

  20. Generalized Lymph Node Activation after Influenza Vaccination on 18F FDG-PET/CT Imaging, an Important Pitfall in PET Interpretation.

    PubMed

    Ayati, Narjess; Jesudason, Sarah; Berlangieri, Salvatore U; Scott, Andrew M

    2017-01-01

    We report on a 59-year-old female patient with an infected vascular graft investigated with 18 F FDG-PET/CT. The first of two studies showed FDG activity in the left deltoid and ipsilateral axillary lymph nodes explained by influenza vaccination the day prior. The second 18 F FDG-PET/CT showed multiple FDG-avid lymph nodes on both sides of the diaphragm without tracer accumulation at the vaccination site. Three months later the CT was negative for lymphadenopathy within the chest or abdominal region. Although influenza vaccination is a potential source of false positive results in FDG PET studies, generalised lymph node activation post vaccination is a rare finding with only one prior published report in individuals infected with HIV-1. This case emphasizes the necessity of taking a history of vaccination prior to a FDG PET study, and consideration of a vaccine-related immune response even without evidence of tracer activity at the vaccination site when generalised FDG-avid lymphadenopathy is encountered.

  1. Hyperpolarized Magnetic Resonance: A Novel Technique for the In Vivo Assessment of Cardiovascular Disease

    PubMed Central

    Schroeder, Marie A.; Clarke, Kieran; Neubauer, Stefan; Tyler, Damian J.

    2011-01-01

    Non-invasive imaging plays a central role in cardiovascular disease for determining diagnosis, prognosis, and optimizing patient management. Recent experimental studies have demonstrated that monitoring hyperpolarized 13C-labelled tracers with magnetic resonance imaging and spectroscopy (MRI and MRS) offers a new way to investigate the normal and diseased heart, and that the technology may be useful in patients with heart disease. In this review, we show how hyperpolarized 13C-labelled tracers are generated and have been applied experimentally, and outline the methodological advances currently underway to enable translation of hyperpolarized 13C MRI and MRS into the clinic. Using hyperpolarized 13C-labelled metabolites and metabolic MRI and MRS could help assessment of many human cardiovascular diseases, including coronary artery disease, heart failure and metabolic cardiomyopathies. We discuss the clinical areas in which the technology may, in the future, aid in the diagnosis and management of patients with cardiovascular diseases, including dynamic investigations of in vivo metabolism, coronary angiography and quantitative perfusion imaging. It is possible that, in the future, hyperpolarized magnetic resonance will play a major role in clinical cardiology. PMID:21969318

  2. Chemistry in CESM-SE: Evaluation, Performance and Optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamarque, Jean-Francois; Conley, Andrew; Vitt, Francis

    2016-01-06

    The purpose of the proposed work focused on development of chemistry representation within the Spectral Element (SE) dynamical core as implemented in the Community Earth System Model (CESM). More specifically, a main focus was on the ability of SE to accurately represent tracer transport. The proposed approach was to incrementally increase the complexity of the problem, starting from specified two-dimensional flow and tracers to simulations using specified dynamics and full chemistry. As demonstrated below, we have successfully studied all aspects of the proposed work, although only part of the work has been published in the refereed literature so far. Furthermore,more » because the SE dynamical core has been found to have several deficiencies that are still being investigated for solution, not all proposed tasks were finalized. In addition to the tests for SE performance, in an effort to decrease the computational burden of interactive chemistry, especially in the case of a large number of chemical species and chemical reactions, development on a faster chemical solver and implementation on GPUs has been implemented in CESM under the leadership of John Drake (U. Tennessee).« less

  3. Concurrent determination of 237Np and Pu isotopes using ICP-MS: analysis of NIST environmental matrix standard reference materials 4357, 1646a, and 2702.

    PubMed

    Matteson, Brent S; Hanson, Susan K; Miller, Jeffrey L; Oldham, Warren J

    2015-04-01

    An optimized method was developed to analyze environmental soil and sediment samples for (237)Np, (239)Pu, and (240)Pu by ICP-MS using a (242)Pu isotope dilution standard. The high yield, short time frame required for analysis, and the commercial availability of the (242)Pu tracer are significant advantages of the method. Control experiments designed to assess method uncertainty, including variation in inter-element fractionation that occurs during the purification protocol, suggest that the overall precision for measurements of (237)Np is typically on the order of ± 5%. Measurements of the (237)Np concentration in a Peruvian Soil blank (NIST SRM 4355) spiked with a known concentration of (237)Np tracer confirmed the accuracy of the method, agreeing well with the expected value. The method has been used to determine neptunium and plutonium concentrations in several environmental matrix standard reference materials available from NIST: SRM 4357 (Radioactivity Standard), SRM 1646a (Estuarine Sediment) and SRM 2702 (Inorganics in Marine Sediment). Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Across North America tracer experiment (ANATEX): Sampling and analysis

    NASA Astrophysics Data System (ADS)

    Draxler, R. R.; Dietz, R.; Lagomarsino, R. J.; Start, G.

    Between 5 January 1987 and 29 March 1987, there were 33 releases of different tracers from each of two sites: Glasgow, MT and St. Cloud, MN. The perfluorocarbon tracers were routinely released in a 3-h period every 2.5 days, alternating between daytime and night-time tracer releases. Ground-level air samples of 24-h duration were taken at 77 sites mostly located near rawinsonde stations east of 105°W and between 26°N and 55°N. Weekly air samples were taken at 12 remote sites between San Diego, CA and Pt. Barrow, AK and between Norway and the Canary Islands. Short-term 6-h samples were collected at ground level and 200 m AGL along an arc of five towers between Tulsa, OK and Green Bay, WI. Aircraft sampling within several hundred kilometers of both tracer release sites was used to establish the initial tracer path. Experimental design required improved sampler performance, new tracers with lower atmospheric backgrounds, and improvements in analytic precision. The advances to the perfluorocarbon tracer system are discussed in detail. Results from the tracer sampling showed that the average and peak concentrations measured over the daily ground-level sampling network were consistent with what would be calculated using mass conservative approaches. however, ground-level samples from individual tracer patterns showed considerable complexity due to vertical stability or the interaction of the tracer plumes with low pressure and frontal systems. These systems could pass right through the tracer plume without appreciable effect. Aircraft tracer measurements are used to confirm the initial tracer trajectory when the narrow plume may miss the coarser spaced ground-level sampling network. Tower tracer measurements showed a more complex temporal structure than evident from the longer duration ground-level sampling sites. Few above background plume measurements were evident in the more distant remote sampling network due to larger than expected uncertainties in the ambient background concentrations.

  5. On the pathways and timescales of intercontinental air pollution transport

    NASA Astrophysics Data System (ADS)

    Stohl, Andreas; Eckhardt, Sabine; Forster, Caroline; James, Paul; Spichtinger, Nicole

    2002-12-01

    This paper presents results of a 1-year simulation of the transport of six passive tracers, released over the continents according to an emission inventory for carbon monoxide (CO). Lagrangian concepts are introduced to derive age spectra of the tracer concentrations on a global grid in order to determine the timescales and pathways of pollution export from the continents. Calculating these age spectra is equivalent to simulating many (quasi continuous) plumes, each starting at a different time, which are subsequently merged. Movies of the tracer dispersion have been made available on an Internet website. It is found that emissions from Asia experience the fastest vertical transport, whereas European emissions have the strongest tendency to remain in the lower troposphere. European emissions are transported primarily into the Arctic and appear to be the major contributor to the Arctic haze problem. Tracers from an upwind continent first arrive over a receptor continent in the upper troposphere, typically after some 4 days. Only later foreign tracers also arrive in the lower troposphere. Assuming a 2-day lifetime, the domestic tracers dominate total tracer columns over all continents except over Australia where foreign tracers account for 20% of the tracer mass. In contrast, for a 20-day lifetime even continents with high domestic emissions receive more than half of their tracer burden from foreign continents. Three special regions were identified where tracers are transported to, and tracer dilution is slow. Future field studies therefore should be deployed in the following regions: (1) In the winter, the Asia tracer accumulates over Indonesia and the Indian Ocean, a region speculated to be a stratospheric fountain. (2) In the summer, the highest concentrations of the Asia tracer are found in the Middle East. (3) In the summer, the highest concentrations of the North America tracer are found in the Mediterranean.

  6. Lanthanide-labeled clay: A new method for tracing sediment transport in Karst

    USGS Publications Warehouse

    Mahler, B.J.; Bennett, P.C.; Zimmerman, M.

    1998-01-01

    Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and quantified by high performance liquid chromatography. The tracer meets the following desired criteria: low detection limit; a number of differentiable signatures; inexpensive production and quantification using standard methods; no environmental risks; and hydrodynamic properties similar to the in situ sediment it is designed to trace. The tracer was tested in laboratory batch experiments and field tested in both surface water and ground water systems. In surface water, arrival times of the tracer were similar to those of a conservative water tracer, although a significant amount of material was lost due to settling. Two tracer tests were undertaken in a karst aquifer under different flow conditions. Under normal flow conditions, the time of arrival and peak concentration of the tracer were similar to or preceded that of a conservative water tracer. Under low flow conditions, the particle tracer was not detected, suggesting that in low flow the sediment settles out of suspension and goes into storage.Mobile sediment is a fundamental yet poorly characterized aspect of mass transport through karst aquifers. Here the development and field testing of an extremely sensitive particle tracer that may be used to characterize sediment transport in karst aquifers is described. The tracer consists of micron-size montmorillonite particles homoionized to the lanthanide form; after injection and retrieval from a ground water system, the lanthanide ions are chemically stripped from the clay and quantified by high performance liquid chromatography. The tracer meets the following desired criteria: low detection limit; a number of differentiable signatures; inexpensive production and quantification using standard methods; no environmental risks; and hydrodynamic properties similar to the in situ sediment it is designed to trace. The tracer was tested in laboratory batch experiments and field tested in both surface water and ground water systems. In surface water, arrival times of the tracer were similar to those of a conservative water tracer, although a significant amount of material was lost due to settling. Two tracer tests were undertaken in a karst aquifer under different flow conditions. Under normal flow conditions, the time of arrival and peak concentration of the tracer were similar to or preceded that of a conservative water tracer. Under low flow conditions, the particle tracer was not detected, suggesting that in low flow the sediment settles out of suspension and goes into storage.

  7. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation.

    PubMed

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker; Fredenslund, Anders M; Scheutz, Charlotte

    2018-09-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument and tracer gas combinations. Analytical instruments with a high detection frequency and good precision were established as the most suitable for successful TDM application. The application of an instrument with a poor precision could only to some extent be overcome by applying a higher tracer gas release rate. A sideward misplacement of the tracer gas release point of about 250m resulted in an emission rate comparable to those obtained using a tracer gas correctly simulating the methane emission. Conversely, an upwind misplacement of about 150m resulted in an emission rate overestimation of almost 50%, showing the importance of proper emission source simulation when applying the TDM. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. STORM-SEWER FLOW MEASUREMENT AND RECORDING SYSTEM.

    USGS Publications Warehouse

    Kilpatrick, Frederick A.; Kaehrle, William R.

    1986-01-01

    A comprehensive study and development of instruments and techniques for measuring all components of flow in a storm-sewer drainage system were undertaken by the U. S. Geological Survey under the sponsorship of FHWA. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, and electromagnetic velocity meters as well as the development and calibration of pneumatic bubbler and pressure transducer head-measuring systems. Tracer dilution and acoustic-flowmeter measurements were used in field verification tests. A single micrologger was used to record data from all the instruments and also to activate on command the electromagnetic velocity meter and tracer dilution systems.

  9. Automated GMP-production of α-[11 C]Methyl-L-tryptophan using a tracer production system (TPS).

    PubMed

    Nordeman, Patrik; Yngve, Ulrika; Wilking, Helena; Gustavsson, Sven Åke; Eriksson, Jonas; Antoni, Gunnar

    2018-06-14

    The radiosynthesis and GMP validation of [ 11 C] AMT for human use is described. Three consecutive batches were produced giving 940-3790 MBq (4-17% RCY, decay corrected, based on [ 11 C]CO 2 ). The molar activity at the end of synthesis was 19-35 GBq/μmol, the radiochemical purity was ≥98% and the enantiomeric purity was >99%. While the synthesis method was automated using a new generation of synthesis equipment, Tracer Production System (TPS) developed in house, the method should be readily applicable to other synthesis platforms with minor modifications. This article is protected by copyright. All rights reserved.

  10. Measurements of HFC-134a and HCFC-22 in groundwater and unsaturated-zone air: implications for HFCs and HCFCs as dating tracers

    USGS Publications Warehouse

    Haase, Karl B.; Busenberg, Eurybiades; Plummer, Niel; Casile, Gerolamo; Sanford, Ward E.

    2014-01-01

    A new analytical method using gas chromatography with an atomic emission detector (GC–AED) was developed for measurement of ambient concentrations of hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) in soil, air, and groundwater, with the goal of determining their utility as groundwater age tracers. The analytical detection limits of HCFC-22 (difluorochloromethane, CHClF2) and HFC-134a (1,2,2,2-tetrafluoroethane, C2H2F4) in 1 L groundwater samples are 4.3 × 10− 1 and 2.1 × 10− 1 pmol kg− 1, respectively, corresponding to equilibrium gas-phase mixing ratios of approximately 5–6 parts per trillion by volume (pptv). Under optimal conditions, post-1960 (HCFC-22) and post-1995 (HFC-134a) recharge could be identified using these tracers in stable, unmixed groundwater samples. Ambient concentrations of HCFC-22 and HFC-134a were measured in 50 groundwater samples from 27 locations in northern and western parts of Virginia, Tennessee, and North Carolina (USA), and 3 unsaturated-zone profiles were collected in northern Virginia. Mixing ratios of both HCFC-22 and HFC-134a decrease with depth in unsaturated-zone gas profiles with an accompanying increase in CO2 and loss of O2. Apparently, ambient concentrations of HCFC-22 and HFC-134a are readily consumed by methanotrophic bacteria under aerobic conditions in the unsaturated zone. The results of this study indicate that soils are a sink for these two greenhouse gases. These observations contradict the previously reported results from microcosm experiments that found that degradation was limited above-ambient HFC-134a. The groundwater HFC and HCFC concentrations were compared with concentrations of chlorofluorocarbons (CFCs, CFC-11, CFC-12, CFC-113) and sulfur hexafluoride (SF6). Nearly all samples had measured HCFC-22 or HFC-134a that were below concentrations predicted by the CFCs and SF6, with many samples showing a complete loss of HCFC-22 and HFC-134a. This study indicates that HCFC-22 and HFC-134a are not conservative as environmental tracers and leaves in question the usefulness of other HCFCs and HFCs as candidate age tracers.

  11. Tracer-Test Planning Using the Efficient Hydrologic Tracer ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be

  12. Journal: A Review of Some Tracer-Test Design Equations for ...

    EPA Pesticide Factsheets

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estimation equations are reviewed here, 32 of which were evaluated using previously published tracer-test design examination parameters. Comparison of the results produced a wide range of estimated tracer mass, but no means is available by which one equation may be reasonably selected over the others. Each equation produces a simple approximation for tracer mass. Most of the equations are based primarily on estimates or measurements of discharge, transport distance, and suspected transport times. Although the basic field parameters commonly employed are appropriate for estimating tracer mass, the 33 equations are problematic in that they were all probably based on the original developers' experience in a particular field area and not necessarily on measured hydraulic parameters or solute-transport theory. Suggested sampling frequencies are typically based primarily on probable transport distance, but with little regard to expected travel times. This too is problematic in that tends to result in false negatives or data aliasing. Simulations from the recently developed efficient hydrologic tracer-test design methodology (EHTD) were compared with those obtained from 32 of the 33 published tracer-

  13. Test of synthetic DNA tracers in a periodic hydrodynamic system for time-variable transit time distribution assessment

    NASA Astrophysics Data System (ADS)

    Dahlke, H. E.; Wang, C.; McNew, C.; McLaughlin, S.; Lyon, S. W.

    2016-12-01

    Recent research on time-varying transport through hydrologic systems proposed using decomposed over-printed tracer breakthrough curves to directly observe transport through complex flow systems. This method, also known as the PERTH (Periodic Tracer Hierarchy) method requires periodic flow and multiple tracer injections to reveal changes in flow pathways and transport behavior. Time-variable transit time distributions (TTD) estimated from tracer breakthrough curves often vary with the storage state of the system, which in turn is influenced by internal and external variabilities, such as the arrangement of flow pathways and fluctuations in system inputs. Deciphering internal from external variabilities in TTDs might help to advance the use of TTDs for estimating the physical state of a system; however, thus far the finite number of unique conservative tracers available for tracing has limited deeper insights. Synthetic DNA tracers consisting of short strands of synthetic DNA encapsulated by polylactic acid (PLA) microspheres could potentially provide multiple unique tracers with identical transport properties needed to explore time varying transport through hydrologic systems in more detail. An experiment was conducted on the miniLeo hillslope, a 1 m3 sloping lysimeter, within the Biosphere 2 Landscape Evolution Observatory near Tucson, AZ to investigate transit time variability. The goal of the experiment was to 1) test the suitability of using synthetic DNA tracers for estimating TTDs in a hydrologic system and 2) to determine the TTDs of individual tracer pulses under periodic steady-state conditions. Five DNA tracers, consisting of four unique, encapsulated DNA sequences and one free/non-encapsulated DNA sequence, were applied as reference and probe tracers together with deuterium, using the PERTH method. The lysimeter received three 2-hour pulses of rainfall at a rate of 30 mm/hr for 10 days. Initial results show that both the encapsulated and free DNA tracers were successfully transported in a pulsed manner through the system, but had overall longer breakthrough times than the reference deuterium tracer. Comparison of the DNA probe tracers indicate differences in transit times, likely related to differences in tracer mobilization in response to the time-variant rainfall input.

  14. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz-Dietsch, J.; Tost, H.; Sander, R.; Pozzer, A.

    2008-03-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, hereinafter referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques. Tagging means the artificial decomposition of one or more species into parts, which are additionally labelled (e.g., by the region of their primary emission) and then processed as the species itself. The type-2 family concept is designed to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (e.g., rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC, which allows the definition of tracers via a Fortran95 namelist, as a complement to the standard tracer definition by application of the TRACER interface routines in the code. TRACER with its submodels and PTRAC can readily be applied to a variety of models without further requirements. The code and a documentation are included in the electronic supplement.

  15. LARGE-SCALE NATURAL GRADIENT TRACER TEST IN SAND AND GRAVEL, CAPE COD, MASSACHUSETTS - 1. EXPERIMENTAL DESIGN AND OBSERVED TRACER MOVEMENT

    EPA Science Inventory

    A large-scale natural gradient tracer experiment was conducted on Cape Cod, Massachusetts, to examine the transport and dispersion of solutes in a sand and gravel aquifer. The nonreactive tracer, bromide, and the reactive tracers, lithium and molybdate, were injected as a pulse i...

  16. Follitropin receptors in rat testis. Characterization with enzymatically 125I-labeled human follitropin.

    PubMed

    Ketelslegers, J M; Catt, K J

    1978-07-03

    The interaction between enzymatically radioiodinated human follitropin and the follitropin receptors in testis homogenate was investigated in immature and adult rats. The 125I-labeled human follitropin exhibited high binding activity with specific binding of up to 17% in the presence of an excess of testis homogenate. Approx. 50% of the bound hormone could be eluted at pH 5, and the receptor purified tracer exhibited a 3.6-fold increase in binding activity when compared with the original tracer preparation. Quantitative analysis of equilibrium binding data was performed with corrections for the measured specific activity and maximum binding activity of the tracer hormone. The equilibrium association constants (Ka) determined 24 degrees C were not significantly different in immature and adult rat testis, and the mean value for Ka was 3.9 . 10(9) M-1. At 37 degrees C, the Ka value obtained using immature rat testis was 1.3 . 10(10) M-1. The association of 125I-labeled human follitropin with immature rat testis homogenate was time and temperature dependent. In the presence of an excess of unlabeled hormone, 30--60% of the preformed hormone . receptor complex was dissociated after 24 h incubation. A specific and sensitive radioligand-receptor assay for follitropin was developed using immature rat testis homogenate. The minimum detectable dose of purified human follitropin was 0.6 ng, and human urinary and pituitary follitropin, ovine follitropin and pregnant mare serum gonadotropin reacted in the assay with equivalent slopes. The potencies of highly purified pregnent mare serum gonadotropin and highly purified human follitropin were similar in the radioligand-receptor assay, consistent with the follitropin bioactivity of the equine gonadotropin.

  17. Tuning structure and mobility of solvation shells surrounding tracer additives.

    PubMed

    Carmer, James; Jain, Avni; Bollinger, Jonathan A; van Swol, Frank; Truskett, Thomas M

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083-4089 (2012)]. For the latter case, we show that the mobility of surrounding solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer's enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.

  18. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    USGS Publications Warehouse

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  19. Non-universal tracer diffusion in crowded media of non-inert obstacles.

    PubMed

    Ghosh, Surya K; Cherstvy, Andrey G; Metzler, Ralf

    2015-01-21

    We study the diffusion of a tracer particle, which moves in continuum space between a lattice of excluded volume, immobile non-inert obstacles. In particular, we analyse how the strength of the tracer-obstacle interactions and the volume occupancy of the crowders alter the diffusive motion of the tracer. From the details of partitioning of the tracer diffusion modes between trapping states when bound to obstacles and bulk diffusion, we examine the degree of localisation of the tracer in the lattice of crowders. We study the properties of the tracer diffusion in terms of the ensemble and time averaged mean squared displacements, the trapping time distributions, the amplitude variation of the time averaged mean squared displacements, and the non-Gaussianity parameter of the diffusing tracer. We conclude that tracer-obstacle adsorption and binding triggers a transient anomalous diffusion. From a very narrow spread of recorded individual time averaged trajectories we exclude continuous type random walk processes as the underlying physical model of the tracer diffusion in our system. For moderate tracer-crowder attraction the motion is found to be fully ergodic, while at stronger attraction strength a transient disparity between ensemble and time averaged mean squared displacements occurs. We also put our results into perspective with findings from experimental single-particle tracking and simulations of the diffusion of tagged tracers in dense crowded suspensions. Our results have implications for the diffusion, transport, and spreading of chemical components in highly crowded environments inside living cells and other structured liquids.

  20. Two-dimensional distribution of microbial activity and flow patterns within naturally fractured chalk.

    PubMed

    Arnon, Shai; Ronen, Zeev; Adar, Eilon; Yakirevich, Alexander; Nativ, Ronit

    2005-10-01

    The two-dimensional distribution of flow patterns and their dynamic change due to microbial activity were investigated in naturally fractured chalk cores. Long-term biodegradation experiments were conducted in two cores ( approximately 20 cm diameter, 31 and 44 cm long), intersected by a natural fracture. 2,4,6-tribromophenol (TBP) was used as a model contaminant and as the sole carbon source for aerobic microbial activity. The transmissivity of the fractures was continuously reduced due to biomass accumulation in the fracture concurrent with TBP biodegradation. From multi-tracer experiments conducted prior to and following the microbial activity, it was found that biomass accumulation causes redistribution of the preferential flow channels. Zones of slow flow near the fracture inlet were clogged, thus further diverting the flow through zones of fast flow, which were also partially clogged. Quantitative evaluation of biodegradation and bacterial counts supported the results of the multi-tracer tests, indicating that most of the bacterial activity occurs close to the inlet. The changing flow patterns, which control the nutrient supply, resulted in variations in the concentrations of the chemical constituents (TBP, bromide and oxygen), used as indicators of biodegradation.

  1. COMPARISON OF THREE TRACER TESTS AT THE RAFT RIVER GEOTHERMAL SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Earl D Mattson; Mitchell Plummer; Carl Palmer

    2011-02-01

    Three conservative tracer tests have been conducted through the Bridge Fault fracture zone at the Raft River Geothermal (RRG) site. All three tests were conducted between injection well RRG-5 and production wells RRG-1 (790 m distance) and RRG-4 (740 m distance). The injection well is used during the summer months to provide pressure support to the production wells. The first test was conducted in 2008 using 136 kg of fluorescein tracer. Two additional tracers were injected in 2010. The first 2010 tracer injected was 100 kg fluorescein disodium hydrate salt on June, 21. The second tracer (100 kg 2,6-naphthalene disulfonicmore » acid sodium salt) was injected one month later on July 21. Sampling of the two productions wells is still being performed to obtain the tail end of the second 2010 tracer test. Tracer concentrations were measured using HPLC with a fluorescence detector. Results for the 2008 test, suggest 80% tracer recover at the two production wells. Of the tracer recovered, 85% of tracer mass was recovered in well RRG-4 indicating a greater flow pathway connection between injection well and RRG-4 than RRG-1. Fluorescein tracer results appear to be similar between the 2008 and 2010 tests for well RRG-4 with peak concentrations arriving approximately 20 days after injection despite the differences between the injection rates for the two tests (~950 gpm to 475 gpm) between the 2008 and 2010. The two 2010 tracer tests will be compared to determine if the results support the hypothesis that rock contraction along the flow pathway due to the 55 oC cooler water injection alters the flow through the ~140 oC reservoir.« less

  2. Application of multiple tracers (SF6 and chloride) to identify the transport by characteristics of contaminant at two separate contaminated sites

    NASA Astrophysics Data System (ADS)

    Lee, K. K.; Lee, S. S.; Kim, H. H.; Koh, E. H.; Kim, M. O.; Lee, K.; Kim, H. J.

    2016-12-01

    Multiple tracers were applied for source and pathway detection at two different sites. CO2 gas injected in the subsurface for a shallow-depth CO2 injection and leak test can be regarded as a potential contaminant source. Therefore, it is necessary to identify the migration pattern of CO2 gas. Also, at a DNAPL contaminated site, it is important to figure out the characteristics of plume evolution from the source zone. In this study, multiple tracers (SF6 and chloride) were used to evaluate the applicability of volatile and non-volatile tracers and to identify the characteristics of contaminant transport at each CO2 injection and leak test site and DNAPL contaminated site. Firstly, at the CO2 test site, multiple tracers were used to perform the single well push-drift-pull tracer test at total 3 specific depth zones. As results of tests, volatile and non-volatile tracers showed different mass recovery percentage. Most of chloride mass was recovered but less than half of SF6 mass was recovered due to volatile property. This means that only gaseous SF6 leak out to unsaturated zone. However, breakthrough curves of both tracers indicated similar peak time, effective porosity, and regional groundwater velocity. Also, at both contaminated sites, natural gradient tracer tests were performed with multiple tracers. With the results of natural gradient tracer test, it was possible to confirm the applicability of multiple tracers and to understand the contaminant transport in highly heterogeneous aquifer systems through the long-term monitoring of tracers. Acknowledgement: financial support was provided by the R&D Project on Environmental Management of Geologic CO2 Storage)" from the KEITI (Project Number: 2014001810003) and Korea Ministry of Environment as "The GAIA project (2014000540010)".

  3. Multitracer test for the determination of transport and in-situ degradation of organic micro-contaminants in karst aquifers on the example of caffeine

    NASA Astrophysics Data System (ADS)

    Hillebrand, O.; Nödler, K.; Licha, T.; Geyer, T.

    2012-04-01

    The application of organic micro-contaminants as indicators for contamination sources in aquifers and surface-water bodies has been increasingly discussed in the literature over the last years. One of the proposed substances was caffeine. It served as indicator for wastewater-leakage to various systems. As well, wastewater volumes could be estimated from caffeine concentrations. Although caffeine is known to be degradable, the degradation rates are normally only determined from mass balances or laboratory experiments. Degradation rates obtained from mass balances are relatively uncertain, as the input-function is difficult to be assessed. Laboratory experiments are hardly capable to consider the full complexity of natural systems and can rarely be transferred to those. To solve this problem, in-situ degradation rates of reactive indicators have to be determined. Especially multitracer tests can be used to access compound-specific transport parameters and degradation rates, relative to conservative tracers. A multitracer test with caffeine and uranine has been performed in a karst system (catchment of the Gallusquelle spring, SW Germany). From the breakthrough curves of the tracers, the transport behavior and the in-situ degradation rate of caffeine could be deduced. The tracers were injected into a sinkhole with a linear distance of 3000 m to the spring. The mean residence time of the tracers was found to be 84 h at a flow velocity of 35 m/h. Throughout the whole experiment, the spring discharge was constant at 187 L/s. Uranine served as conservative reference-tracer for the calibration of a one-dimensional transport model with respect to solute-unspecific parameters. Relative to that, the tracer breakthrough curve of caffeine was interpreted. As solute-specific parameters the retardation coefficient as well as degradation rate of caffeine in the investigated karst aquifer could be determined. The results indicate, that caffeine is slightly retarded in the investigated aquifer (R= 1.031-1.046) and is readily degradable (half-life t1/2= 90-105 h; temperature of the spring water T= 8-9 °C). The degradation rate is surprisingly high. In general, no significant degradation is believed to occur, during the rapid transport in karst systems. The high degradation rates of caffeine illustrate the potential to use this substance as reactive tracer to indicate biological activity within the aquifer. Due to the good degradability of caffeine it does not pose a threat as long-time contamination and can therefore safely be used as reactive tracer in aquifer systems.

  4. Technical Note: Coupling of chemical processes with the Modular Earth Submodel System (MESSy) submodel TRACER

    NASA Astrophysics Data System (ADS)

    Jöckel, P.; Kerkweg, A.; Buchholz, J.; Tost, H.; Sander, R.; Pozzer, A.

    2007-11-01

    The implementation of processes related to chemistry into Earth System Models and their coupling within such systems requires the consistent description of the chemical species involved. We provide a tool (written in Fortran95) to structure and manage information about constituents, herein after referred to as tracers, namely the Modular Earth Submodel System (MESSy) generic (i.e., infrastructure) submodel TRACER. With TRACER it is possible to define a multitude of tracer sets, depending on the spatio-temporal representation (i.e., the grid structure) of the model. The required information about a specific chemical species is split into the static meta-information about the characteristics of the species, and its (generally in time and space variable) abundance in the corresponding representation. TRACER moreover includes two submodels. One is TRACER_FAMILY, an implementation of the tracer family concept. It distinguishes between two types: type-1 families are usually applied to handle strongly related tracers (e.g., fast equilibrating species) for a specific process (e.g., advection). In contrast to this, type-2 families are applied for tagging techniques, in which specific species are artificially decomposed and associated with additional information, in order to conserve the linear relationship between the family and its members. The second submodel is TRACER_PDEF, which corrects and budgets numerical negative overshoots that arise in many process implementations due to the numerical limitations (limited precision, rounding errors). The submodel therefore guarantees the positive definiteness of the tracers and stabilises the integration scheme. As a by-product, it further provides a global tracer mass diagnostic. Last but not least, we present the submodel PTRAC for the definition of prognostic tracers via a Fortran95 namelist. TRACER with its submodels and PTRAC can readily be applied to a variety of models without further requirements. The code and a documentation is included in the electronic supplement.

  5. 3-D numerical evaluation of density effects on tracer tests.

    PubMed

    Beinhorn, M; Dietrich, P; Kolditz, O

    2005-12-01

    In this paper we present numerical simulations carried out to assess the importance of density-dependent flow on tracer plume development. The scenario considered in the study is characterized by a short-term tracer injection phase into a fully penetrating well and a natural hydraulic gradient. The scenario is thought to be typical for tracer tests conducted in the field. Using a reference case as a starting point, different model parameters were changed in order to determine their importance to density effects. The study is based on a three-dimensional model domain. Results were interpreted using concentration contours and a first moment analysis. Tracer injections of 0.036 kg per meter of saturated aquifer thickness do not cause significant density effects assuming hydraulic gradients of at least 0.1%. Higher tracer input masses, as used for geoelectrical investigations, may lead to buoyancy-induced flow in the early phase of a tracer test which in turn impacts further plume development. This also holds true for shallow aquifers. Results of simulations with different tracer injection rates and durations imply that the tracer input scenario has a negligible effect on density flow. Employing model cases with different realizations of a log conductivity random field, it could be shown that small variations of hydraulic conductivity in the vicinity of the tracer injection well have a major control on the local tracer distribution but do not mask effects of buoyancy-induced flow.

  6. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    DOEpatents

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  7. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE PAGES

    Bosler, Peter Andrew; Kent, James; Krasny, Robert; ...

    2017-03-30

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  8. A Lagrangian particle method with remeshing for tracer transport on the sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosler, Peter Andrew; Kent, James; Krasny, Robert

    A Lagrangian particle method (called LPM) based on the flow map is presented for tracer transport on the sphere. The particles carry tracer values and are located at the centers and vertices of triangular Lagrangian panels. Remeshing is applied to control particle disorder and two schemes are compared, one using direct tracer interpolation and another using inverse flow map interpolation with sampling of the initial tracer density. Test cases include a moving-vortices flow and reversing-deformational flow with both zero and nonzero divergence, as well as smooth and discontinuous tracers. We examine the accuracy of the computed tracer density and tracermore » integral, and preservation of nonlinear correlation in a pair of tracers. Here, we compare results obtained using LPM and the Lin–Rood finite-volume scheme. An adaptive particle/panel refinement scheme is demonstrated.« less

  9. Theoretical foundation for measuring the groundwater age distribution.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardner, William Payton; Arnold, Bill Walter

    2014-01-01

    In this study, we use PFLOTRAN, a highly scalable, parallel, flow and reactive transport code to simulate the concentrations of 3H, 3He, CFC-11, CFC-12, CFC-113, SF6, 39Ar, 81Kr, 4He and themean groundwater age in heterogeneous fields on grids with an excess of 10 million nodes. We utilize this computational platform to simulate the concentration of multiple tracers in high-resolution, heterogeneous 2-D and 3-D domains, and calculate tracer-derived ages. Tracer-derived ages show systematic biases toward younger ages when the groundwater age distribution contains water older than the maximum tracer age. The deviation of the tracer-derived age distribution from the true groundwatermore » age distribution increases with increasing heterogeneity of the system. However, the effect of heterogeneity is diminished as the mean travel time gets closer the tracer age limit. Age distributions in 3-D domains differ significantly from 2-D domains. 3D simulations show decreased mean age, and less variance in age distribution for identical heterogeneity statistics. High-performance computing allows for investigation of tracer and groundwater age systematics in high-resolution domains, providing a platform for understanding and utilizing environmental tracer and groundwater age information in heterogeneous 3-D systems. Groundwater environmental tracers can provide important constraints for the calibration of groundwater flow models. Direct simulation of environmental tracer concentrations in models has the additional advantage of avoiding assumptions associated with using calculated groundwater age values. This study quantifies model uncertainty reduction resulting from the addition of environmental tracer concentration data. The analysis uses a synthetic heterogeneous aquifer and the calibration of a flow and transport model using the pilot point method. Results indicate a significant reduction in the uncertainty in permeability with the addition of environmental tracer data, relative to the use of hydraulic measurements alone. Anthropogenic tracers and their decay products, such as CFC11, 3H, and 3He, provide significant constraint oninput permeability values in the model. Tracer data for 39Ar provide even more complete information on the heterogeneity of permeability and variability in the flow system than the anthropogenic tracers, leading to greater parameter uncertainty reduction.« less

  10. Assessing the Accuracy of the Tracer Dilution Method with Atmospheric Dispersion Modeling

    NASA Astrophysics Data System (ADS)

    Taylor, D.; Delkash, M.; Chow, F. K.; Imhoff, P. T.

    2015-12-01

    Landfill methane emissions are difficult to estimate due to limited observations and data uncertainty. The mobile tracer dilution method is a widely used and cost-effective approach for predicting landfill methane emissions. The method uses a tracer gas released on the surface of the landfill and measures the concentrations of both methane and the tracer gas downwind. Mobile measurements are conducted with a gas analyzer mounted on a vehicle to capture transects of both gas plumes. The idea behind the method is that if the measurements are performed far enough downwind, the methane plume from the large area source of the landfill and the tracer plume from a small number of point sources will be sufficiently well-mixed to behave similarly, and the ratio between the concentrations will be a good estimate of the ratio between the two emissions rates. The mobile tracer dilution method is sensitive to different factors of the setup such as placement of the tracer release locations and distance from the landfill to the downwind measurements, which have not been thoroughly examined. In this study, numerical modeling is used as an alternative to field measurements to study the sensitivity of the tracer dilution method and provide estimates of measurement accuracy. Using topography and wind conditions for an actual landfill, a landfill emissions rate is prescribed in the model and compared against the emissions rate predicted by application of the tracer dilution method. Two different methane emissions scenarios are simulated: homogeneous emissions over the entire surface of the landfill, and heterogeneous emissions with a hot spot containing 80% of the total emissions where the daily cover area is located. Numerical modeling of the tracer dilution method is a useful tool for evaluating the method without having the expense and labor commitment of multiple field campaigns. Factors tested include number of tracers, distance between tracers, distance from landfill to transect path, and location of tracers with respect to the hot spot. Results show that location of the tracers relative to the hot spot of highest landfill emissions makes the largest difference in accuracy of the tracer dilution method.

  11. Heat and solute tracers: how do they compare in heterogeneous aquifers?

    PubMed

    Irvine, Dylan J; Simmons, Craig T; Werner, Adrian D; Graf, Thomas

    2015-04-01

    A comparison of groundwater velocity in heterogeneous aquifers estimated from hydraulic methods, heat and solute tracers was made using numerical simulations. Aquifer heterogeneity was described by geostatistical properties of the Borden, Cape Cod, North Bay, and MADE aquifers. Both heat and solute tracers displayed little systematic under- or over-estimation in velocity relative to a hydraulic control. The worst cases were under-estimates of 6.63% for solute and 2.13% for the heat tracer. Both under- and over-estimation of velocity from the heat tracer relative to the solute tracer occurred. Differences between the estimates from the tracer methods increased as the mean velocity decreased, owing to differences in rates of molecular diffusion and thermal conduction. The variance in estimated velocity using all methods increased as the variance in log-hydraulic conductivity (K) and correlation length scales increased. The variance in velocity for each scenario was remarkably small when compared to σ2 ln(K) for all methods tested. The largest variability identified was for the solute tracer where 95% of velocity estimates ranged by a factor of 19 in simulations where 95% of the K values varied by almost four orders of magnitude. For the same K-fields, this range was a factor of 11 for the heat tracer. The variance in estimated velocity was always lowest when using heat as a tracer. The study results suggest that a solute tracer will provide more understanding about the variance in velocity caused by aquifer heterogeneity and a heat tracer provides a better approximation of the mean velocity. © 2013, National Ground Water Association.

  12. Can nanotechnology help advance glaciological research?

    NASA Astrophysics Data System (ADS)

    Dahlke, H. E.; McNew, C.; Wang, C.; McLaughlin, S.; Kocis, T. N.

    2017-12-01

    In a rapidly changing cryosphere, identifying sources, pathways, and residence times of snow and glacier meltwater is critical to developing improved understanding of watershed-stream connections and hydrological/glaciological melt models. Traditionally, glaciologists have used a variety of tracers, including chloride, microparticles, and dyes, to identify the structure and morphology of subglacial drainage systems. However, minimum detection limits, tracer expense, and the ability of watersheds to retain a memory of past tracer inputs have restricted both the scale of tracer application and the repeated or simultaneous use of most known tracers, thus limiting our ability to study complex glacial systems. These shortcomings in hydrologic tracers can be overcome by utilizing a tracer that allows for the unique identification between spatial and temporal inputs while maintaining identical transport characteristics. Here, we present the use of DNA-labeled nanoparticles, developed for nano-medicine and drug delivery, as environmental tracers. The DNA-labeled particle tracers consist of short DNA strands encapsulated within biodegradable polymer microspheres, which allow for repeatable production of numerous uniquely labelled tracers of pre-determined size and physical transport properties. Each batch of tracers are independently quantifiable; even a single DNA molecule can be detected with cost-effective quantitative polymerase chain reaction (qPCR). We have tested our tracer technology in complex systems such as valley glaciers in Sweden and Alaska and in both laboratory and field studies of channel flow, overland flow, and flow in porous media; these proof-of-concept studies indicate that nanotechnology allows for powerful characterization, description, and, ultimately, prediction of flow pathways in glacial systems and the environment.

  13. Complex functionality with minimal computation: Promise and pitfalls of reduced-tracer ocean biogeochemistry models

    NASA Astrophysics Data System (ADS)

    Galbraith, Eric D.; Dunne, John P.; Gnanadesikan, Anand; Slater, Richard D.; Sarmiento, Jorge L.; Dufour, Carolina O.; de Souza, Gregory F.; Bianchi, Daniele; Claret, Mariona; Rodgers, Keith B.; Marvasti, Seyedehsafoura Sedigh

    2015-12-01

    Earth System Models increasingly include ocean biogeochemistry models in order to predict changes in ocean carbon storage, hypoxia, and biological productivity under climate change. However, state-of-the-art ocean biogeochemical models include many advected tracers, that significantly increase the computational resources required, forcing a trade-off with spatial resolution. Here, we compare a state-of-the art model with 30 prognostic tracers (TOPAZ) with two reduced-tracer models, one with 6 tracers (BLING), and the other with 3 tracers (miniBLING). The reduced-tracer models employ parameterized, implicit biological functions, which nonetheless capture many of the most important processes resolved by TOPAZ. All three are embedded in the same coupled climate model. Despite the large difference in tracer number, the absence of tracers for living organic matter is shown to have a minimal impact on the transport of nutrient elements, and the three models produce similar mean annual preindustrial distributions of macronutrients, oxygen, and carbon. Significant differences do exist among the models, in particular the seasonal cycle of biomass and export production, but it does not appear that these are necessary consequences of the reduced tracer number. With increasing CO2, changes in dissolved oxygen and anthropogenic carbon uptake are very similar across the different models. Thus, while the reduced-tracer models do not explicitly resolve the diversity and internal dynamics of marine ecosystems, we demonstrate that such models are applicable to a broad suite of major biogeochemical concerns, including anthropogenic change. These results are very promising for the further development and application of reduced-tracer biogeochemical models that incorporate "sub-ecosystem-scale" parameterizations.

  14. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunden, Melissa; Faulkner, David; Heredia, Elizabeth

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison betweenmore » different gas sampling methods, and the effect of different ventilation conditions.« less

  15. First-in-Human Assessment of the Novel PDE2A PET Radiotracer 18F-PF-05270430

    PubMed Central

    Waterhouse, Rikki N.; Nabulsi, Nabeel; Lin, Shu-Fei; Labaree, David; Ropchan, Jim; Tarabar, Sanela; DeMartinis, Nicholas; Ogden, Adam; Banerjee, Anindita; Huang, Yiyun; Carson, Richard E.

    2016-01-01

    This was a first-in-human study of the novel phosphodiesterase-2A (PDE2A) PET ligand 18F-PF-05270430. The primary goals were to determine the appropriate tracer kinetic model to quantify brain uptake and to examine the within-subject test–retest variability. Methods: In advance of human studies, radiation dosimetry was determined in nonhuman primates. Six healthy male subjects participated in a test–retest protocol with dynamic scans and metabolite-corrected input functions. Nine brain regions of interest were studied, including the striatum, white matter, neocortical regions, and cerebellum. Multiple modeling methods were applied to calculate volume of distribution (VT) and binding potentials relative to the nondisplaceable tracer in tissue (BPND), concentration of tracer in plasma (BPP), and free tracer in tissue (BPF). The cerebellum was selected as a reference region to calculate binding potentials. Results: The dosimetry study provided an effective dose of less than 0.30 mSv/MBq, with the gallbladder as the critical organ; the human target dose was 185 MBq. There were no adverse events or clinically detectable pharmacologic effects reported. Tracer uptake was highest in the striatum, followed by neocortical regions and white matter, and lowest in the cerebellum. Regional time–activity curves were well fit by multilinear analysis-1, and a 70-min scan duration was sufficient to quantify VT and the binding potentials. BPND, with mean values ranging from 0.3 to 0.8, showed the best intrasubject and intersubject variability and reliability. Test–retest variability in the whole brain (excluding the cerebellum) of VT, BPND, and BPP were 8%, 16%, and 17%, respectively. Conclusion: 18F-PF-05270430 shows promise as a PDE2A PET ligand, albeit with low binding potential values. PMID:27103022

  16. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  17. Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...

  18. Development of an online p38α mitogen-activated protein kinase binding assay and integration of LC–HR-MS

    PubMed Central

    Falck, David; de Vlieger, Jon S. B.; Niessen, Wilfried M. A.; Kool, Jeroen; Honing, Maarten; Irth, Hubertus

    2010-01-01

    A high-resolution screening method was developed for the p38α mitogen-activated protein kinase to detect and identify small-molecule binders. Its central role in inflammatory diseases makes this enzyme a very important drug target. The setup integrates separation by high-performance liquid chromatography with two parallel detection techniques. High-resolution mass spectrometry gives structural information to identify small molecules while an online enzyme binding detection method provides data on p38α binding. The separation step allows the individual assessment of compounds in a mixture and links affinity and structure information via the retention time. Enzyme binding detection was achieved with a competitive binding assay based on fluorescence enhancement which has a simple principle, is inexpensive, and is easy to interpret. The concentrations of p38α and the fluorescence tracer SK&F86002 were optimized as well as incubation temperature, formic acid content of the LC eluents, and the material of the incubation tubing. The latter notably improved the screening of highly lipophilic compounds. For optimization and validation purposes, the known kinase inhibitors BIRB796, TAK715, and MAPKI1 were used among others. The result is a high-quality assay with Z′ factors around 0.8, which is suitable for semi-quantitative affinity measurements and applicable to various binding modes. Furthermore, the integrated approach gives affinity data on individual compounds instead of averaged ones for mixtures. Figure P38 α online screening platform Electronic supplementary material The online version of this article (doi:10.1007/s00216-010-4087-8) contains supplementary material, which is available to authorized users. PMID:20730527

  19. Microbial water quality before and after the repair of a failing onsite wastewater treatment system adjacent to coastal waters

    USGS Publications Warehouse

    Conn, K.E.; Habteselassie, M.Y.; Denene, Blackwood A.; Noble, R.T.

    2012-01-01

    Aims: The objective was to assess the impacts of repairing a failing onsite wastewater treatment system (OWTS, i.e., septic system) as related to coastal microbial water quality. Methods and Results: Wastewater, groundwater and surface water were monitored for environmental parameters, faecal indicator bacteria (total coliforms, Escherichia coli, enterococci) and the viral tracer MS2 before and after repairing a failing OWTS. MS2 results using plaque enumeration and quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) often agreed, but inhibition limited the qRT-PCR assay sensitivity. Prerepair, MS2 persisted in groundwater and was detected in the nearby creek; postrepair, it was not detected. In groundwater, total coliform concentrations were lower and E.??coli was not detected, while enterococci concentrations were similar to prerepair levels. E.??coli and enterococci surface water concentrations were elevated both before and after the repair. Conclusions: Repairing the failing OWTS improved groundwater microbial water quality, although persistence of bacteria in surface water suggests that the OWTS was not the singular faecal contributor to adjacent coastal waters. A suite of tracers is needed to fully assess OWTS performance in treating microbial contaminants and related impacts on receiving waters. Molecular methods like qRT-PCR have potential but require optimization. Significance and Impact of Study: This is the first before and after study of a failing OWTS and provides guidance on selection of microbial tracers and methods. ?? 2011 The Authors. Journal of Applied Microbiology ?? 2011 The Society for Applied Microbiology.

  20. Urban enhancement of PM10 bioaerosol tracers relative to background locations in the Midwestern United States

    NASA Astrophysics Data System (ADS)

    Rathnayake, Chathurika M.; Metwali, Nervana; Baker, Zach; Jayarathne, Thilina; Kostle, Pamela A.; Thorne, Peter S.; O'Shaughnessy, Patrick T.; Stone, Elizabeth A.

    2016-05-01

    Bioaerosols are well-known immune-active particles that exacerbate respiratory diseases. Human exposures to bioaerosols and their resultant health impacts depend on their ambient concentrations, seasonal and spatial variation, and copollutants, which are not yet widely characterized. In this study, chemical and biological tracers of bioaerosols were quantified in respirable particulate matter (PM10) collected at three urban and three background sites in the Midwestern United States across four seasons in 2012. Endotoxins from Gram-negative bacteria (and a few Gram-positive bacteria), water-soluble proteins, and tracers for fungal spores (fungal glucans, arabitol, and mannitol) were ubiquitous and showed significant seasonal variation and dependence on temperature. Fungal spores were elevated in spring and peaked in summer, following the seasonal growing cycle, while endotoxins peaked in autumn during the row crop harvesting season. Paired comparisons of bioaerosols in urban and background sites revealed significant urban enhancements in PM10, fungal glucans, endotoxins, and water-soluble proteins relative to background locations, such that urban populations have a greater outdoor exposure to bioaerosols. These bioaerosols contribute, in part, to the urban excesses in PM10. Higher bioaerosol mass fractions in urban areas relative to background sites indicate that urban areas serve as a source of bioaerosols. Similar urban enhancements in water-soluble calcium and its correlation with bioaerosol tracers point toward windblown soil as an important source of bioaerosols in urban areas.

  1. Adenosine receptor agonist NECA increases cerebral extravasation of fluorescein and low molecular weight dextran independent of blood-brain barrier modulation

    PubMed Central

    Cheng, Chih-Chung; Yang, Ya Lan; Liao, Kate Hsiurong; Lai, Ted Weita

    2016-01-01

    Conventional methods for therapeutic blood-brain barrier (BBB) disruption facilitate drug delivery but are cumbersome to perform. A previous study demonstrated that adenosine receptor (AR) stimulation by 5′-N-ethylcarboxamide adenosine (NECA) increased the extravasation of intravascular tracers into the brain and proposed that AR agonism may be an effective method for therapeutic BBB disruption. We attempted to confirm the extravasation of tracers into the brain and also investigated tracer extravasation into peripheral organs and tracer retention in the blood. We found that NECA not only increased the extravasation of intravascular fluorescein and low molecular weight dextran into the brain of mice but also increased the concentrations of these tracers in the blood. In fact, the brain:blood ratio-normalized BBB permeability for either tracer is actually decreased by NECA administration. Elevated blood urea nitrogen levels in mice following NECA treatment suggested that renal function impairment was a probable cause of tracer retention. Therefore, NECA has almost no effect on the extravasation of intravascular Evans blue dye (EBD), an albumin-binding tracer with little renal clearance. Rather than inducing BBB disruption, our study demonstrated that NECA increased tracer extravasation into the brain by increasing the concentration gradient of the tracer across the BBB. PMID:27025761

  2. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    NASA Astrophysics Data System (ADS)

    Duan, G.; Zhao, X.; Seren, H. R.; Chen, C.; Zhang, X.

    2015-12-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen.

  3. Adenosine receptor agonist NECA increases cerebral extravasation of fluorescein and low molecular weight dextran independent of blood-brain barrier modulation.

    PubMed

    Cheng, Chih-Chung; Yang, Ya Lan; Liao, Kate Hsiurong; Lai, Ted Weita

    2016-03-30

    Conventional methods for therapeutic blood-brain barrier (BBB) disruption facilitate drug delivery but are cumbersome to perform. A previous study demonstrated that adenosine receptor (AR) stimulation by 5'-N-ethylcarboxamide adenosine (NECA) increased the extravasation of intravascular tracers into the brain and proposed that AR agonism may be an effective method for therapeutic BBB disruption. We attempted to confirm the extravasation of tracers into the brain and also investigated tracer extravasation into peripheral organs and tracer retention in the blood. We found that NECA not only increased the extravasation of intravascular fluorescein and low molecular weight dextran into the brain of mice but also increased the concentrations of these tracers in the blood. In fact, the brain:blood ratio-normalized BBB permeability for either tracer is actually decreased by NECA administration. Elevated blood urea nitrogen levels in mice following NECA treatment suggested that renal function impairment was a probable cause of tracer retention. Therefore, NECA has almost no effect on the extravasation of intravascular Evans blue dye (EBD), an albumin-binding tracer with little renal clearance. Rather than inducing BBB disruption, our study demonstrated that NECA increased tracer extravasation into the brain by increasing the concentration gradient of the tracer across the BBB.

  4. EFFICIENT HYDROLOGICAL TRACER-TEST DESIGN (EHTD ...

    EPA Pesticide Factsheets

    Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed that combines basic measured field parameters (e.g., discharge, distance, cross-sectional area) in functional relationships that describe solute-transport processes related to flow velocity and time of travel. The new method applies these initial estimates for time of travel and velocity to a hypothetical continuously stirred tank reactor as an analog for the hydrologic flow system to develop initial estimates for tracer concentration and axial dispersion, based on a preset average tracer concentration. Root determination of the one-dimensional advection-dispersion equation (ADE) using the preset average tracer concentration then provides a theoretical basis for an estimate of necessary tracer mass.Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to

  5. One year of tracer dispersion measurements over Washington, D.C.

    NASA Astrophysics Data System (ADS)

    Draxler, Roland R.

    Two perfluorocarbon tracers were released for 6 h from several locations about 20 km outside of Washington, D.C. at 36-h intervals for over 1 year. Continuous air samples were collected at 8-h intervals at one urban and two suburban sites, and at monthly intervals at 93 sites all over the region. Over 50 % of the 8-h samples showed no tracer concentration. However, about 20% of the samples had significant amounts of tracer, so that about 600 values under a variety of meteorological conditions are available for analysis. Although the Potomac River is only 100 m below the surrounding terrain, the tracer releases from within the river valley indicated that the tracer flow was channeled along the river valley. For tracer released away from the river valley, the tracer tended to pass aloft and not mix down into the river valley. Sequential concentration measurements frequently showed high values for extended periods after the tracer release terminated, decreasing exponentially with a half life of about 3 h. This suggests that the finite tracer plume may have a rather long upwind trailing edge toward the release point. The average rate of change in the vertical dispersion during summer and winter was found to be proportional to the 0.6 power of distance.

  6. Dose escalation to high-risk sub-volumes based on non-invasive imaging of hypoxia and glycolytic activity in canine solid tumors: a feasibility study

    PubMed Central

    2013-01-01

    Introduction Glycolytic activity and hypoxia are associated with poor prognosis and radiation resistance. Including both the tumor uptake of 2-deoxy-2-[18 F]-fluorodeoxyglucose (FDG) and the proposed hypoxia tracer copper(II)diacetyl-bis(N4)-methylsemithio-carbazone (Cu-ATSM) in targeted therapy planning may therefore lead to improved tumor control. In this study we analyzed the overlap between sub-volumes of FDG and hypoxia assessed by the uptake of 64Cu-ATSM in canine solid tumors, and evaluated the possibilities for dose redistribution within the gross tumor volume (GTV). Materials and methods Positron emission tomography/computed tomography (PET/CT) scans of five spontaneous canine solid tumors were included. FDG-PET/CT was obtained at day 1, 64Cu-ATSM at day 2 and 3 (3 and 24 h pi.). GTV was delineated and CT images were co-registered. Sub-volumes for 3 h and 24 h 64Cu-ATSM (Cu3 and Cu24) were defined by a threshold based method. FDG sub-volumes were delineated at 40% (FDG40) and 50% (FDG50) of SUVmax. The size of sub-volumes, intersection and biological target volume (BTV) were measured in a treatment planning software. By varying the average dose prescription to the tumor from 66 to 85 Gy, the possible dose boost (D B ) was calculated for the three scenarios that the optimal target for the boost was one, the union or the intersection of the FDG and 64Cu-ATSM sub-volumes. Results The potential boost volumes represented a fairly large fraction of the total GTV: Cu3 49.8% (26.8-72.5%), Cu24 28.1% (2.4-54.3%), FDG40 45.2% (10.1-75.2%), and FDG50 32.5% (2.6-68.1%). A BTV including the union (∪) of Cu3 and FDG would involve boosting to a larger fraction of the GTV, in the case of Cu3∪FDG40 63.5% (51.8-83.8) and Cu3∪FDG50 48.1% (43.7-80.8). The union allowed only a very limited D B whereas the intersection allowed a substantial dose escalation. Conclusions FDG and 64Cu-ATSM sub-volumes were only partly overlapping, suggesting that the tracers offer complementing information on tumor physiology. Targeting the combined PET positive volume (BTV) for dose escalation within the GTV results in a limited D B . This suggests a more refined dose redistribution based on a weighted combination of the PET tracers in order to obtain an improved tumor control. PMID:24199939

  7. αVβ3 integrin-targeted microSPECT/CT imaging of inflamed atherosclerotic plaques in mice.

    PubMed

    Vancraeynest, David; Roelants, Véronique; Bouzin, Caroline; Hanin, François-Xavier; Walrand, Stephan; Bol, Vanesa; Bol, Anne; Pouleur, Anne-Catherine; Pasquet, Agnès; Gerber, Bernhard; Lesnik, Philippe; Huby, Thierry; Jamar, François; Vanoverschelde, Jean-Louis

    2016-12-01

    αVβ3-integrin is expressed by activated endothelial cells and macrophages in atherosclerotic plaques and may represent a valuable marker of high-risk plaques. We evaluated (99m)Tc-maraciclatide, an integrin-specific tracer, for imaging vascular inflammation in atherosclerotic lesions in mice. Apolipoprotein E-negative (ApoE(-/-)) mice on a Western diet (n = 10) and normally fed adult C57BL/6 control mice (n = 4) were injected with (99m)Tc-maraciclatide (51.8 ± 3.7 MBq). A blocking peptide was infused in three ApoE(-/-) mice; this condition served as another control. After 90 min, the animals were imaged via single-photon emission computed tomography (SPECT). While maintained in the same position, the mice were transferred to computed tomography (CT) to obtain contrast-enhanced images of the aortic arch. Images from both modalities were fused, and signal was quantified in the aortic arch and in the vena cava for subtraction of blood-pool activity. The aorta was carefully dissected after imaging for gamma counting, autoradiography, and histology. Tracer uptake was significantly higher in ApoE(-/-) mice than in both groups of control mice (1.56 ± 0.33 vs. 0.82 ± 0.24 vs. 0.98 ± 0.11, respectively; P = 0.006). Furthermore, higher tracer activity was detected via gamma counting in the aorta of hypercholesterolemic mice than in both groups of control mice (1.52 ± 0.43 vs. 0.78 ± 0.19 vs. 0.47 ± 0.31 (99m)Tc-maraciclatide %ID/g, respectively; P = 0.018). Autoradiography showed significantly higher tracer uptake in the atherosclerotic aorta than in the control aorta (P = 0.026). Finally, in the atherosclerotic aorta, immunostaining indicated that the integrin signal came predominantly from macrophages and was correlated with the macrophage CD68 immunomarker (r = 0.73). (99m)Tc-maraciclatide allows in vivo detection of inflamed atherosclerotic plaques in mice and may represent a non-invasive approach for identifying high-risk plaques in patients.

  8. Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willem, Henry; Hult, Erin L.; Hotchi, Toshifumi

    2013-01-01

    In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levelsmore » and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange« less

  9. Ventilation Control of Volatile Organic Compounds in New U.S. Homes: Results of a Controlled Field Study in Nine Residential Units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willem, Henry; Hult, Erin L.; Hotchi, Toshifumi

    2013-01-23

    In order to optimize strategies to remove airborne contaminants in residences, it is necessary to determine how contaminant concentrations respond to changes in the air exchange rate. The impact of air exchange rate on the indoor concentrations of 39 target volatile organic compounds (VOCs) was assessed by measuring air exchange rates and VOC concentrations at three ventilation settings in nine residences. Active sampling methods were used for VOC concentration measurements, and passive perfluorocarbon tracer gas emitters with active sampling were used to determine the overall air exchange rate corresponding to the VOC measurements at each ventilation setting. The concentration levelsmore » and emission rates of the target VOCs varied by as much as two orders of magnitude across sites. Aldehyde and terpene compounds were typically the chemical classes with highest concentrations, followed by alkanes, aromatics, and siloxanes. For each home, VOC concentrations tended to decrease as the air exchange rate was increased, however, measurement uncertainty was significant. The indoor concentration was inversely proportional to air exchange rate for most compounds. For a subset of compounds including formaldehyde, however, the indoor concentration exhibited a non-linear dependence on the timescale for air exchange.« less

  10. 3-D Modelling the effect of river excavation on surface water and groundwater relation in a bank filtration system - comparing electrical conductivity and heat as tracer

    NASA Astrophysics Data System (ADS)

    Wang, Weishi; Oswald, Sascha; Munz, Matthias; Strasser, Daniel

    2017-04-01

    As a pretreatment for conventional drinking water supply, bank filtration (BF) is widely used in Europe, while in Germany it contributes 16% of potable water supply. There are usually two crucial issues for BF influencing its treatment effect, which are separately the spatial and temporal distribution of travelling times and distinguishing between the flow contribution of BF versus inflow from the ambient groundwater. Modelling is a strong tool for analyzing the behavior and development of the flow field, especially for quantification of the river recharge rate of BF and estimation of travel time distribution. Though 3-D modelling of the flow field as a comprehensive tool has been used in several studies, many simulations are limited to pure water flow. Since heads are only partially able to constrain the flow field, model non-uniqueness might lead to misinterpretation of the real flow field, especially in complex geological conditions. Some studies have shown that by including tracers, the model non-uniqueness could be reasonably constrained and the accuracy of flux estimation could be improved. Natural tracers thus are used in groundwater modelling, while differences in their properties or input may cause dissimilar behavior during the transport process. In this study, we have set up a numerical 3-D groundwater flow model of a bank filtration site with strong geological heterogeneity and used the data of several years monitoring activities as the data basis. We were particularly interested in the seasonal dynamics but also structural changes induced by a reconstruction of the surface water including excavation and rebuilding the bank construction. By combining separately electrical conductivity and heat as tracers in the model we were able to i) understand flow field mechanisms and its changes caused by the excavation ii) conclude from the deviations of the tracer concentrations and dynamics simulated compared to the measurements on deficiencies of the flow field; and thus by the tracer study flow field could be improved iii) compare the individual behavior of the tracers in this realistic setting of transport processes also relevant for judging water quality in the pumping wells now and in the future.

  11. Long-term high-level waste technology. Composite report

    NASA Astrophysics Data System (ADS)

    Cornman, W. R.

    1981-12-01

    Research and development studies on the immobilization of high-level wastes from the chemical reprocessing of nuclear reactor fuels are summarized. The reports are grouped under the following tasks: (1) program management and support; (2) waste preparation; (3) waste fixation; and (4) final handling. Some of the highlights are: leaching properties were obtained for titanate and tailored ceramic materials being developed at ICPP to immobilize zirconia calcine; comparative leach tests, hot-cell tests, and process evaluations were conducted of waste form alternatives to borosilicate glass for the immobilization of SRP high-level wastes, experiments were run at ANL to qualify neutron activation analysis and radioactive tracers for measuring leach rates from simulated waste glasses; comparative leach test samples of SYNROC D were prepared, characterized, and tested at LLNL; encapsulation of glass marbles with lead or lead alloys was demonstrated on an engineering scale at PNL; a canister for reference Commercial HLW was designed at PNL; a study of the optimization of salt-crete was completed at SRL; a risk assessment showed that an investment for tornado dampers in the interim storage building of the DWPF is unjustified.

  12. Preparation and preclinical evaluation of 68Ga-DOTA-amlodipine for L-type calcium channel imaging.

    PubMed

    Firuzyar, Tahereh; Jalilian, Amir Reza; Aboudzadeh, Mohammad Reza; Sadeghpour, Hossein; Shafiee-Ardestani, Mahdi; Khalaj, Ali

    2016-01-01

    In order to develop a possible tracer for L-type calcium channel imaging, we here report the development of a Ga-68 amlodipine derivative for possible PET imaging. Amlodipine DOTA conjugate was synthesized, characterized and went through calcium channel blockade, toxicity, apoptosis/necrosis tests. [ 68 Ga] DOTA AMLO was prepared at optimized conditions followed by stability tests, partition coefficient determination and biodistribution studies using tissue counting and co incidence imaging up to 2 h. [ 68 Ga] DOTA AMLO was prepared at pH 4-5 in 7-10 min at 95°C in high radiochemical purity (>99%, radio thin layer chromatography; specific activity: 1.9-2.1 GBq/mmol) and was stable up to 4 h with a log P of -0.94. Calcium channel rich tissues including myocardium, and tissues with smooth muscle cells such as colon, intestine, and lungs demonstrated significant uptake. Co incidence images supported the biodistribution data up to 2 h. The complex can be a candidate for further positron emission tomography imaging for L type calcium channels.

  13. Method to determine 226Ra in small sediment samples by ultralow background liquid scintillation.

    PubMed

    Sanchez-Cabeza, Joan-Albert; Kwong, Laval Liong Wee; Betti, Maria

    2010-08-15

    (210)Pb dating of sediment cores is a widely used tool to reconstruct ecosystem evolution and historical pollution during the last century. Although (226)Ra can be determined by gamma spectrometry, this method shows severe limitations which are, among others, sample size requirements and counting times. In this work, we propose a new strategy based on the analysis of (210)Pb through (210)Po in equilibrium by alpha spectrometry, followed by the determination of (226)Ra (base or supported (210)Pb) without any further chemical purification by liquid scintillation and with a higher sample throughput. Although gamma spectrometry might still be required to determine (137)Cs as an independent tracer, the effort can then be focused only on those sections dated around 1963, when maximum activities are expected. In this work, we optimized the counting conditions, calibrated the system for changing quenching, and described the new method to determine (226)Ra in small sediment samples, after (210)Po determination, allowing a more precise determination of excess (210)Pb ((210)Pb(ex)). The method was validated with reference materials IAEA-384, IAEA-385, and IAEA-313.

  14. An innovative approach for highly selective direct conversion of CO₂ into propanol using C₂H₄ and H₂.

    PubMed

    Ahlers, Stefan J; Bentrup, Ursula; Linke, David; Kondratenko, Evgenii V

    2014-09-01

    Multifunctional catalysts are developed for converting CO2 with C2H4 and H2 into propanol. Au nanoparticles (NP) supported on TiO2 are found to facilitate this reaction. The activity and selectivity strongly depend on NP size, which can be tuned by the method of Au deposition and by promoting with K. The promoter improves the selectivity to propanol. Under optimized reaction conditions (2 MPa, 473 K, and CO2/H2/C2H4=1:1:1), CO2 is continuously converted into propanol with a near-to-100% selectivity. Catalytic tests as well as mechanistic studies by in situ FTIR and temporal analysis of products with isotopic tracers allow the overall reaction scheme to be determined. Propanol is formed through a sequence of reactions starting with reverse water-gas shift to reduce CO2 to CO, which is further consumed in the hydroformylation of ethylene to propanal. The latter is finally hydrogenated to propanol, while propanol hydrogenation to propane is suppressed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. PSA-Stratified Performance of 18F- and 68Ga-PSMA PET in Patients with Biochemical Recurrence of Prostate Cancer.

    PubMed

    Dietlein, Felix; Kobe, Carsten; Neubauer, Stephan; Schmidt, Matthias; Stockter, Simone; Fischer, Thomas; Schomäcker, Klaus; Heidenreich, Axel; Zlatopolskiy, Boris D; Neumaier, Bernd; Drzezga, Alexander; Dietlein, Markus

    2017-06-01

    Several studies outlined the sensitivity of 68 Ga-labeled PET tracers against the prostate-specific membrane antigen (PSMA) for localization of relapsed prostate cancer in patients with renewed increase in the prostate-specific antigen (PSA), commonly referred to as biochemical recurrence. Labeling of PSMA tracers with 18 F offers numerous advantages, including improved image resolution, longer half-life, and increased production yields. The aim of this study was to assess the PSA-stratified performance of the 18 F-labeled PSMA tracer 18 F-DCFPyL and the 68 Ga-labeled reference 68 Ga-PSMA-HBED-CC. Methods: We examined 191 consecutive patients with biochemical recurrence according to standard acquisition protocols using 18 F-DCFPyL ( n = 62, 269.8 MBq, PET scan at 120 min after injection) or 68 Ga-PSMA-HBED-CC ( n = 129, 158.9 MBq, 60 min after injection). We determined PSA-stratified sensitivity rates for both tracers and corrected our calculations for Gleason scores using iterative matched-pair analyses. As an orthogonal validation, we directly compared tracer distribution patterns in a separate cohort of 25 patients, sequentially examined with both tracers. Results: After prostatectomy ( n = 106), the sensitivity of both tracers was significantly associated with absolute PSA levels ( P = 4.3 × 10 -3 ). Sensitivity increased abruptly, when PSA values exceeded 0.5 μg/L ( P = 2.4 × 10 -5 ). For a PSA less than 3.5 μg/L, most relapses were diagnosed at a still limited stage ( P = 3.4 × 10 -6 ). For a PSA of 0.5-3.5 μg/L, PSA-stratified sensitivity was 88% (15/17) for 18 F-DCFPyL and 66% (23/35) for 68 Ga-PSMA-HBED-CC. This significant difference was preserved in the Gleason-matched-pair analysis. Outside of this range, sensitivity was comparably low (PSA < 0.5 μg/L) or high (PSA > 3.5 μg/L). After radiotherapy ( n = 85), tracer sensitivity was largely PSA-independent. In the 25 patients examined with both tracers, distribution patterns of 18 F-DCFPyL and 68 Ga-PSMA-HBED-CC were strongly comparable ( P = 2.71 × 10 -8 ). However, in 36% of the PSMA-positive patients we detected additional lesions on the 18 F-DCFPyL scan ( P = 3.7 × 10 -2 ). Conclusion: Our data suggest that 18 F-DCFPyL is noninferior to 68 Ga-PSMA-HBED-CC, while offering the advantages of 18 F labeling. Our results indicate that imaging with 18 F-DCFPyL may even exhibit improved sensitivity in localizing relapsed tumors after prostatectomy for moderately increased PSA levels. Although the standard acquisition protocols, used for 18 F-DCFPyL and 68 Ga-PSMA-HBED-CC in this study, stipulate different activity doses and tracer uptake times after injection, our findings provide a promising rationale for validation of 18 F-DCFPyL in future prospective trials. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  16. Molecular Imaging of Matrix Metalloproteinase Activation to Predict Murine Aneurysm Expansion in vivo

    PubMed Central

    Razavian, Mahmoud; Zhang, Jiasheng; Nie, Lei; Tavakoli, Sina; Razavian, Niema; Dobrucki, Lawrence W.; Sinusas, Albert J.; Edwards, D. Scott; Azure, Michael; Sadeghi, Mehran M.

    2010-01-01

    Rupture and dissection are major causes of morbidity and mortality in arterial aneurysm and occur more frequently in rapidly expanding aneurysms. Current imaging modalities provide little information on aneurysm beyond size. MMP activation plays a key role in the pathogenesis of aneurysm. We investigated whether imaging matrix metalloproteinase (MMP) activation in aneurysm helps predict its propensity to expansion. Methods and Results Using a model of carotid aneurysm in apolipoprotein E−/− mice we demonstrate that several MMPs are expressed with distinct temporal patterns in aneurysm. Radiotracers with specificity for activated MMPs were used to detect and quantify MMP activation by microSPECT/CT imaging in vivo. Significant focal uptake was observed in aneurysmal carotid arteries, peaking at 4 weeks after aneurysm induction. Tracer uptake was confirmed by autoradiography and gamma-well counting, and specificity was demonstrated using excess unlabeled precursor and a specific MMP inhibitor. In a group of animals imaged serially at 2 and 4 weeks after aneurysm induction, MMP tracer uptake at 2 weeks correlated well with the vessel area assessed by histology at 4 weeks. Conclusions Molecular imaging of MMP activation is a useful experimental, and potentially clinical, tool to non-invasively predict an aneurysm’s propensity to expansion in vivo. PMID:20554725

  17. Imaging Caspase-3 Activation as a Marker of Apoptosis-Targeted Treatment Response in Cancer

    PubMed Central

    Chen, Delphine L.; Engle, Jacquelyn T.; Griffin, Elizabeth A.; Miller, J. Philip; Chu, Wenhua; Zhou, Dong; Mach, Robert H.

    2016-01-01

    Purpose We tested whether positron emission tomography (PET) with the caspase-3 targeted isatin analog [18F]WC-4-116 could image caspase-3 activation in response to an apoptosis-inducing anticancer therapy. Procedures [18F]WC-4-116 uptake was determined in etoposide-treated EL4 cells. Biodistribution studies with [18F]WC-4-116 and [18F]ICMT-18, a non-caspase-3-targeted tracer, as well as [18F]WC-4-116 microPET imaging assessed responses in Colo205 tumor bearing mice treated with death receptor 5 (DR5) targeted agonist antibodies. Immunohistochemical staining and enzyme assays confirmed caspase-3 activation. Two-way analysis of variance or Student’s t-test assessed for treatment-related changes in tracer uptake. Results [18F]WC-4-116 increased 8 ± 2-fold in etoposide-treated cells. The [18F]WC-4-116 %ID/g also increased significantly in tumors with high caspase-3 enzyme activity (p < 0.05). [18F]ICMT-18 tumor uptake did not differ in tumors with high or low caspase-3 enzyme activity. Conclusions [18F]WC-4-116 uptake in vivo reflects increased caspase-3 activation and may be useful for detecting caspase-3 mediated apoptosis treatment responses in cancer. PMID:25344147

  18. Deuterium used as artificial tracer in column studies under saturated water flow conditions

    NASA Astrophysics Data System (ADS)

    Koeniger, P.; Geiges, M.; Leibundgut, Ch.

    2003-04-01

    In contrast to numerous investigations using deuterium as an environmental tracer, hydrological investigations with deuterium-labelled water are rather rare. Currently applications in groundwater studies are restricted due to increasing costs of spiking large water quantities but an application as intelligent tracer might be of advantage especially in combination with other tracers and under distinct environmental conditions. Therefore deuterium was applied as artificial tracer in column experiments that are well proved as a tool to characterise tracer behaviour in recent studies. Deuterium was tested in comparison to the more familiar conservative tracer fluorescein. Varying experimental conditions, e.g. column length (0.5, 1.0, 1.5 m), initial tracer concentration (0.01, 0.02, 0.2 mg) and flow velocity (1.5 to 6.0 m/d) were used to investigate tracer behaviour under saturated water flow conditions. Deuterium was analysed using an H/Device with chrome reduction connected to an isotope ratio mass spectrometer and expressed in relative concentrations [per mill V-SMOW]. Theoretical tracer breakthrough curves were calculated using a one dimensional dispersion model. The results indicate higher mean transport velocities and smaller dispersion for deuterium in all experiments. Due to different molecule properties that also determine the interaction of soil substrate and tracer, deuterium indicates a more conservative transport behaviour. Deuterium is non-toxic, completely soluble, chemically and biologically stable and not subject to light-influenced decay. Furthermore, it shows promise for investigations of water flow in the unsaturated zone, and of interactions of water in soil-plant-atmosphere systems. A further discussion of problems, together with possibilities for applying deuterium as an artificial tracer, will be presented.

  19. Application of Tracer-Injection Techniques to Demonstrate Surface-Water and Ground-Water Interactions Between an Alpine Stream and the North Star Mine, Upper Animas River Watershed, Southwestern Colorado

    USGS Publications Warehouse

    Wright, Winfield G.; Moore, Bryan

    2003-01-01

    Tracer-injection studies were done in Belcher Gulch in the upper Animas River watershed, southwestern Colorado, to determine whether the alpine stream infiltrates into underground mine workings of the North Star Mine and other nearby mines in the area. The tracer-injection studies were designed to determine if and where along Belcher Gulch the stream infiltrates into the mine. Four separate tracer-injec-tion tests were done using lithium bromide (LiBr), optical brightener dye, and sodium chloride (NaCl) as tracer solu-tions. Two of the tracers (LiBr and dye) were injected con-tinuously for 24 hours, one of the NaCl tracers was injected continuously for 12 hours, and one of the NaCl tracers was injected over a period of 1 hour. Concentration increases of tracer constituents were detected in water discharging from the North Star Mine, substantiating a surface-water and ground-water connection between Belcher Gulch and the North Star Mine. Different timing and magnitude of tracer breakthroughs indicated multiple flow paths with different residence times from the stream to the mine. The Pittsburgh and Sultan Mines were thought to physically connect to the North Star Mine, but tracer breakthroughs were inconclusive in water from these mines. From the tracer-injection tests and synoptic measure-ments of streamflow discharge, a conceptual model was devel-oped for surface-water and ground-water interactions between Belcher Gulch and the North Star Mine. This information, combined with previous surface geophysical surveys indicat-ing the presence of subsurface voids, may assist with decision-making process for preventing infiltration and for the remedia-tion of mine drainage from these mines.

  20. Simultaneous Analyses and Applications of Multiple Fluorobenzoate and Halide Tracers in Hydrologic Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Q; Moran, J E

    2004-01-22

    An analytical method that employs ion chromatography has been developed to more fully exploit the use of fluorobenzoic acids (FBAs) and halides as hydrologic tracers. In a single run, this reliable, sensitive, and robust method can simultaneously separate and quantify halides (fluoride, chloride, bromide, and iodide) and up to seven FBAs from other common groundwater constituents (e.g., nitrate and sulfate). The usefulness of this ion chromatographic (IC) analytical method is demonstrated in both field and laboratory tracer experiments. Field experiments in unsaturated tuff featuring fractures or a fault show that this efficient and cost-effective method helps achieve the objectives ofmore » tracer studies that use multiple FBAs and/or diffusivity tracers (simultaneous use of one or more FBA and halide). The field study examines the hydrologic response of fractures and the matrix to different flow rates and the contribution of matrix diffusion in chemical transport. Laboratory tracer experiments with eight geologic media from across the United States--mostly from Department of Energy facilities where groundwater contamination is prevalent and where subsurface characterization employing tracers has been ongoing or is in need--reveal several insights about tracer transport behavior: (1) Bromide and FBAs are not always transported conservatively. (2) The delayed transport of these anionic tracers is likely related to geologic media characteristics, such as organic matter, pH, iron oxide content, and clay mineralogy. (3) Any use of iodine as a hydrologic tracer should take into account the different sorption behaviors of iodide and iodate and the possible conversion of iodine's initial chemical form. (4) The transport behavior of potential FBA and halide tracers under relevant geochemical conditions should be evaluated before beginning ambitious, large-scale field tracer experiments.« less

  1. Translation of New Molecular Imaging Approaches to the Clinical Setting: Bridging the Gap to Implementation.

    PubMed

    van Es, Suzanne C; Venema, Clasina M; Glaudemans, Andor W J M; Lub-de Hooge, Marjolijn N; Elias, Sjoerd G; Boellaard, Ronald; Hospers, Geke A P; Schröder, Carolina P; de Vries, Elisabeth G E

    2016-02-01

    Molecular imaging with PET is a rapidly emerging technique. In breast cancer patients, more than 45 different PET tracers have been or are presently being tested. With a good rationale, after development of the tracer and proven feasibility, it is of interest to evaluate whether there is a potential meaningful role for the tracer in the clinical setting-such as in staging, in the (early) prediction of a treatment response, or in supporting drug choices. So far, only (18)F-FDG PET has been incorporated into breast cancer guidelines. For proof of the clinical relevance of tracers, especially for analysis in a multicenter setting, standardization of the technology and access to the novel PET tracer are required. However, resources for PET implementation research are limited. Therefore, next to randomized studies, novel approaches are required for proving the clinical value of PET tracers with the smallest possible number of patients. The aim of this review is to describe the process of the development of PET tracers and the level of evidence needed for the use of these tracers in breast cancer. Several breast cancer trials have been performed with the PET tracers (18)F-FDG, 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), and (18)F-fluoroestradiol ((18)F-FES). We studied them to learn lessons for the implementation of novel tracers. After defining the gap between a good rationale for a tracer and implementation in the clinical setting, we propose solutions to fill the gap to try to bring more PET tracers to daily clinical practice. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  2. Complex functionality with minimal computation. Promise and pitfalls of reduced-tracer ocean biogeochemistry models

    DOE PAGES

    Galbraith, Eric D.; Dunne, John P.; Gnanadesikan, Anand; ...

    2015-12-21

    Earth System Models increasingly include ocean biogeochemistry models in order to predict changes in ocean carbon storage, hypoxia, and biological productivity under climate change. However, state-of-the-art ocean biogeochemical models include many advected tracers, that significantly increase the computational resources required, forcing a trade-off with spatial resolution. Here, we compare a state-of the art model with 30 prognostic tracers (TOPAZ) with two reduced-tracer models, one with 6 tracers (BLING), and the other with 3 tracers (miniBLING). The reduced-tracer models employ parameterized, implicit biological functions, which nonetheless capture many of the most important processes resolved by TOPAZ. All three are embedded inmore » the same coupled climate model. Despite the large difference in tracer number, the absence of tracers for living organic matter is shown to have a minimal impact on the transport of nutrient elements, and the three models produce similar mean annual preindustrial distributions of macronutrients, oxygen, and carbon. Significant differences do exist among the models, in particular the seasonal cycle of biomass and export production, but it does not appear that these are necessary consequences of the reduced tracer number. With increasing CO2, changes in dissolved oxygen and anthropogenic carbon uptake are very similar across the different models. Thus, while the reduced-tracer models do not explicitly resolve the diversity and internal dynamics of marine ecosystems, we demonstrate that such models are applicable to a broad suite of major biogeochemical concerns, including anthropogenic change. Lastly, these results are very promising for the further development and application of reduced-tracer biogeochemical models that incorporate ‘‘sub-ecosystem-scale’’ parameterizations.« less

  3. Rooting depth distribution and nitrogen acquisition using 15N tracer, Barrow, Alaska, 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colleen Iversen

    Permafrost thaw and degradation may lead to altered thickness of the active soil layer and a changing distribution of plant-available nutrients throughout the soil, but little is known about the nutrient acquisition strategies of dominant tundra plant species. We conducted an 15N isotope tracer experiment to assess the vertical distribution of nutrient acquisition among three dominant species representing important plant functional types (PFTs) on the Barrow Environmental Observatory (BEO) in Barrow, Alaska. We found that vertical patterns of root distribution and nutrient acquisition varied among plant species, and that root density may not entirely explain patterns of nutrient acquisition formore » all species.« less

  4. 18F-NaF PET Demonstrating Unusual Focal Tracer Activity in the Brain.

    PubMed

    Thenkondar, Anuradha; Jafari, Lida; Sooriash, Robbie; Hajsadeghi, Fereshteh; Berenji, Gholam R; Li, Yuxin

    2017-02-01

    A 60-year-old man with enlarged prostate, hypertension, and diabetes was referred for F-NaF PET/CT to evaluate possible metastatic lesions. The patient appeared asymptomatic on the day of the study, without any signs indicating stroke. Patient also had no known history of malignancy or cerebrovascular disease. He had mild elevation of the prostate-specific antigen level, and biopsy of his prostate was not performed. Patient had long-standing history of chronic back pain and abdominal pain. The PET bone scan demonstrated a large area of very intense tracer uptake in the brain. A subsequent brain MRI revealed prior stroke in the same area.

  5. A line source tracer test - a better method for assessing high groundwater velocity

    NASA Astrophysics Data System (ADS)

    Magal, E.; Weisbrod, N.; Yakirevich, A.; Kurtzman, D.; Yechieli, Y.

    2009-12-01

    A line source injection is suggested as an effective method for assessing groundwater velocities and flow directions in subsurface characterized by high water fluxes. Modifying the common techniques of injecting a tracer into a well was necessary after frequently-used methods of natural and forced gradient tracer tests ended with no reliable information on the local groundwater flow. In a field experiment, tracers were injected into 8-m long line injection system constructed below the water table almost perpendicular to the assumed flow direction. The injection system was divided to four separate segments (each 2 m long) enabling the injection of four different tracers along the line source. An array of five boreholes located in an area of 10x10 m downstream was used for monitoring the tracers' transport. Two dye tracers (Uranine and Na Naphthionate) were injected in a long pulse of several hours into two of the injection pipe segments and two tracers (Rhenium oxide and Gd-DTPA) were instantaneously injected to the other two segments. The tracers were detected 0.7 to 2.3 hours after injection in four of the five observation wells, located 2.3 to 10 m from the injection system, respectively. Groundwater velocities were calculated directly from the tracers' arrival times and by fitting the observed breakthrough curves to simulations with one and two dimensions analytical solutions for conservative tracer transport. The groundwater velocity was determined to be ~100 m/d. The longitudinal dispersivity value, generated from fitting the tracer breakthrough curves, was in a range of 0.2-3m. The groundwater flow direction was derived based on the arrival of the tracers and was found to be consistent with the apparent direction of the hydraulic gradient. The hydraulic conductivity derived from the groundwater velocity was ~1200 m/d, which is in the upper range of gravel sediment.

  6. Coarsening of physics for biogeochemical model in NEMO

    NASA Astrophysics Data System (ADS)

    Bricaud, Clement; Le Sommer, Julien; Madec, Gurvan; Deshayes, Julie; Chanut, Jerome; Perruche, Coralie

    2017-04-01

    Ocean mesoscale and submesoscale turbulence contribute to ocean tracer transport and to shaping ocean biogeochemical tracers distribution. Representing adequately tracer transport in ocean models therefore requires to increase model resolution so that the impact of ocean turbulence is adequately accounted for. But due to supercomputers power and storage limitations, global biogeochemical models are not yet run routinely at eddying resolution. Still, because the "effective resolution" of eddying ocean models is much coarser than the physical model grid resolution, tracer transport can be reconstructed to a large extent by computing tracer transport and diffusion with a model grid resolution close to the effective resolution of the physical model. This observation has motivated the implementation of a new capability in NEMO ocean model (http://www.nemo-ocean.eu/) that allows to run the physical model and the tracer transport model at different grid resolutions. In a first time, we present results obtained with this new capability applied to a synthetic age tracer in a global eddying model configuration. In this model configuration, ocean dynamic is computed at ¼° resolution but tracer transport is computed at 3/4° resolution. The solution obtained is compared to 2 reference setup ,one at ¼° resolution for both physics and passive tracer models and one at 3/4° resolution for both physics and passive tracer model. We discuss possible options for defining the vertical diffusivity coefficient for the tracer transport model based on information from the high resolution grid. We describe the impact of this choice on the distribution and one the penetration of the age tracer. In a second time we present results obtained by coupling the physics with the biogeochemical model PISCES. We look at the impact of this methodology on some tracers distribution and dynamic. The method described here can found applications in ocean forecasting, such as the Copernicus Marine service operated by Mercator-Ocean, and in Earth System Models for climate applications.

  7. Fractured-rock hydrogeophysics with electrically conductive and neutrally buoyant tracers

    NASA Astrophysics Data System (ADS)

    Shakas, A.; Linde, N.; Baron, L.; Le Borgne, T.; Bour, O.; Lavenant, N.; Gerard, M. F.

    2016-12-01

    Artificial tracer tests help to characterize and understand the dynamics of groundwater systems. This remains a challenging task, especially when dealing with highly heterogeneous formations in which flow can be very localized and the interpretation of tracer breakthrough curves may be ambiguous. As a complement to tracer tests, ground-penetrating radar (GPR) and electrical resistivity tomography can map the space-time migration of electrically conductive tracers. In hydrogeophysics, the most common tracer is dissolved table salt in water. However, conventional salt tracers lead to density effects that are often ignored. Even less than 1% density variations can have a dramatic effect on transport behavior and affect tracer tests in complex ways. Such effects have been demonstrated in our previous experiments that used single-hole GPR to monitor saline push-pull tests in fractured granite. It is possible to model density effects, but this leads to computational complexity and field dynamics that are not necessarily representative of the natural responses of the system. To minimize density effects, we performed a new set of push-pull tests using a neutrally buoyant and electrically conductive tracer at the same test site located close to Ploemeur, France. This novel tracer consists of a mixture of salt (NaCl), water and pure ethanol. Ethanol has a density of 789 g/L at 20° C and is used to counter-act the salt-induced density increase. Our GPR time-lapse images and tracer breakthrough data indicate a largely reversible transport process that confirms the neutral buoyancy of the tracer. Ethanol is biodegradable and does not pose significant environmental issues. Furthermore, calibration of the neutral-buoyant mixture is straightforward to perform in the field using Archimedes principle. Based on these results, we argue that neutrally buoyant ethanol-salt-water mixtures are ideal for a wide variety of hydrogeophysical tracer tests in porous or fractured media.

  8. Comparison of thermal, salt and dye tracing to estimate shallow flow velocities: Novel triple-tracer approach

    NASA Astrophysics Data System (ADS)

    Abrantes, João R. C. B.; Moruzzi, Rodrigo B.; Silveira, Alexandre; de Lima, João L. M. P.

    2018-02-01

    The accurate measurement of shallow flow velocities is crucial to understand and model the dynamics of sediment and pollutant transport by overland flow. In this study, a novel triple-tracer approach was used to re-evaluate and compare the traditional and well established dye and salt tracer techniques with the more recent thermal tracer technique in estimating shallow flow velocities. For this purpose a triple tracer (i.e. dyed-salted-heated water) was used. Optical and infrared video cameras and an electrical conductivity sensor were used to detect the tracers in the flow. Leading edge and centroid velocities of the tracers were measured and the correction factors used to determine the actual mean flow velocities from tracer measured velocities were compared and investigated. Experiments were carried out for different flow discharges (32-1813 ml s-1) on smooth acrylic, sand, stones and synthetic grass bed surfaces with 0.8, 4.4 and 13.2% slopes. The results showed that thermal tracers can be used to estimate shallow flow velocities, since the three techniques yielded very similar results without significant differences between them. The main advantages of the thermal tracer were that the movement of the tracer along the measuring section was more easily visible than it was in the real image videos and that it was possible to measure space-averaged flow velocities instead of only one velocity value, with the salt tracer. The correction factors used to determine the actual mean velocity of overland flow varied directly with Reynolds and Froude numbers, flow velocity and slope and inversely with flow depth and bed roughness. In shallow flows, velocity estimation using tracers entails considerable uncertainty and caution must be taken with these measurements, especially in field studies where these variables vary appreciably in space and time.

  9. Tuning structure and mobility of solvation shells surrounding tracer additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmer, James; Jain, Avni; Bollinger, Jonathan A.

    2015-03-28

    Molecular dynamics simulations and a stochastic Fokker-Planck equation based approach are used to illuminate how position-dependent solvent mobility near one or more tracer particle(s) is affected when tracer-solvent interactions are rationally modified to affect corresponding solvation structure. For tracers in a dense hard-sphere fluid, we compare two types of tracer-solvent interactions: (1) a hard-sphere-like interaction, and (2) a soft repulsion extending beyond the hard core designed via statistical mechanical theory to enhance tracer mobility at infinite dilution by suppressing coordination-shell structure [Carmer et al., Soft Matter 8, 4083–4089 (2012)]. For the latter case, we show that the mobility of surroundingmore » solvent particles is also increased by addition of the soft repulsive interaction, which helps to rationalize the mechanism underlying the tracer’s enhanced diffusivity. However, if multiple tracer surfaces are in closer proximity (as at higher tracer concentrations), similar interactions that disrupt local solvation structure instead suppress the position-dependent solvent dynamics.« less

  10. Fractal continuum model for tracer transport in a porous medium.

    PubMed

    Herrera-Hernández, E C; Coronado, M; Hernández-Coronado, H

    2013-12-01

    A model based on the fractal continuum approach is proposed to describe tracer transport in fractal porous media. The original approach has been extended to treat tracer transport and to include systems with radial and uniform flow, which are cases of interest in geoscience. The models involve advection due to the fluid motion in the fractal continuum and dispersion whose mathematical expression is taken from percolation theory. The resulting advective-dispersive equations are numerically solved for continuous and for pulse tracer injection. The tracer profile and the tracer breakthrough curve are evaluated and analyzed in terms of the fractal parameters. It has been found in this work that anomalous transport frequently appears, and a condition on the fractal parameter values to predict when sub- or superdiffusion might be expected has been obtained. The fingerprints of fractality on the tracer breakthrough curve in the explored parameter window consist of an early tracer breakthrough and long tail curves for the spherical and uniform flow cases, and symmetric short tailed curves for the radial flow case.

  11. Comparison of different tracers for PIV measurements in EHD airflow

    NASA Astrophysics Data System (ADS)

    Hamdi, M.; Havet, M.; Rouaud, O.; Tarlet, D.

    2014-04-01

    In this study, a proposed method for selecting a tracer for particle imaging velocimetry (PIV) measurement in electrohydrodynamics flows was developed. To begin with, several published studies were identified that exploit different tracers, such as oil smoke, cigarette smoke and titanium dioxide (TiO2). An assortment of tracers was then selected based on comparisons with conventional dimensionless numbers; Stokes number ( St), Archimedes number ( Ar) and electrical mobility ratio ( M). Subsequently, an experimental study for testing tracers was developed, which enabled the velocity profile of an ionic wind generated by a needle/ring configuration to be measured. Air velocity measurements carried out with a Pitot tube, considered as the reference measurements, were compared to PIV measurements for each tracer. In addition, the current-voltage curves and the evolution of the current during seeding were measured. All the experimental results show that TiO2, SiO2 microballoons and incense smoke are the ideal tracers in the series of tracers investigated.

  12. Impacts of Siberian biomass burning on organic aerosols over the North Pacific Ocean and the Arctic: primary and secondary organic tracers.

    PubMed

    Ding, Xiang; Wang, Xinming; Xie, Zhouqing; Zhang, Zhou; Sun, Liguang

    2013-04-02

    During the 2003 Chinese Arctic Research Expedition (CHINARE2003) from the Bohai Sea to the high Arctic (37°N-80°N), filter-based particle samples were collected and analyzed for tracers of primary and secondary organic aerosols (SOA) as well as water-soluble organic carbon (WSOC). Biomass burning (BB) tracer levoglucosan had comparatively much higher summertime average levels (476 ± 367 pg/m(3)) during our cruise due to the influence of intense forest fires then in Siberia. On the basis of 5-day back trajectories, samples with air masses passing through Siberia had organic tracers 1.3-4.4 times of those with air masses transporting only over the oceans, suggesting substantial contribution of continental emissions to organic aerosols in the marine atmosphere. SOA tracers from anthropogenic aromatics were negligible or not detected, while those from biogenic terpenenoids were ubiquitously observed with the sum of SOA tracers from isoprene (623 ± 414 pg/m(3)) 1 order of magnitude higher than that from monoterpenes (63 ± 49 pg/m(3)). 2-Methylglyceric acid as a product of isoprene oxidation under high-NOx conditions was dominant among SOA tracers, implying that these BSOA tracers were not formed over the oceans but mainly transported from the adjacent Siberia where a high-NOx environment could be induced by intense forest fires. The carbon fractions shared by biogenic SOA tracers and levoglucosan in WSOC in our ocean samples were 1-2 orders of magnitude lower than those previously reported in continental samples, BB emissions or chamber simulation samples, largely due to the chemical evolution of organic tracers during transport. As a result of the much faster decline in levels of organic tracers than that of WSOC during transport, the trace-based approach, which could well reconstruct WSOC using biogenic SOA and BB tracers for continental samples, only explained ∼4% of measured WSOC during our expedition if the same tracer-WSOC or tracer-SOC relationships were applied.

  13. Dual-tracer background subtraction approach for fluorescent molecular tomography

    PubMed Central

    Holt, Robert W.; El-Ghussein, Fadi; Davis, Scott C.; Samkoe, Kimberley S.; Gunn, Jason R.; Leblond, Frederic

    2013-01-01

    Abstract. Diffuse fluorescence tomography requires high contrast-to-background ratios to accurately reconstruct inclusions of interest. This is a problem when imaging the uptake of fluorescently labeled molecularly targeted tracers in tissue, which can result in high levels of heterogeneously distributed background uptake. We present a dual-tracer background subtraction approach, wherein signal from the uptake of an untargeted tracer is subtracted from targeted tracer signal prior to image reconstruction, resulting in maps of targeted tracer binding. The approach is demonstrated in simulations, a phantom study, and in a mouse glioma imaging study, demonstrating substantial improvement over conventional and homogenous background subtraction image reconstruction approaches. PMID:23292612

  14. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  15. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  16. 10 CFR 39.45 - Subsurface tracer studies.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Subsurface tracer studies. 39.45 Section 39.45 Energy....45 Subsurface tracer studies. (a) The licensee shall require all personnel handling radioactive tracer material to use protective gloves and, if required by the license, other protective clothing and...

  17. Plan for radionuclide tracer studies of the residence time distribution in the Wilsonville dissolver and preheater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jolley, R.L.; Begovich, J.M.; Brashear, H.R.

    1983-12-01

    Stimulus-response measurements using radiotracers to measure residence time distribution (RTD) and hydrodynamic parameters for the preheaters and dissolvers at the Ft. Lewis Solvent Refined Coal (SRC) and the Exxon Donor Solvent (EDS) coal conversion pilot plants are reviewed. A plan is also presented for a series of radioactive tracer studies proposed for the Advanced Coal Liquefaction Facility at Wilsonville, Alabama, to measure the RTD for the preheater and dissolvers in the SRC-I mode. The tracer for the gas phase will be /sup 133/Xe, and /sup 198/Au (on carbonized resin or as an aqueous colloidal suspension) will be used as themore » slurry tracer. Four experimental phases are recommended for the RTD tracer studies: (1) preheater; (2) dissolver with 100% takeoff; (3) dissolver with 100% takeoff and solids withdrawal; and (4) dissolver with 50% takeoff. Eighteen gas-tracer and 22 liquid-tracer injections are projected to accomplish the four experimental phases. Two to four tracer injections are projected for preliminary tests to ensure the capability of safe injection of the radiotracers and the collection of statistically significant data. A complete projected cost and time schedule is provided, including procurement of necessary components, preparation of the radiotracers, assembly and testing of tracer injection apparatus and detection systems, onsite work and tracer injections, laboratory experimentation, data analysis, and report writing.« less

  18. Chemical Tool Peer Review Summary.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cashion, Avery Ted; Cieslewski, Grzegorz

    Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoirmore » by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.« less

  19. NMED Correspondence Related to Notice of Intent for Chromium Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Ellena Isabel

    Two methods of injection using a solution containing 50 kilograms (kg) of tracer are proposed for each well. Half of the tracer (25 kg) may be mixed with 3,000 gallons of potable water and delivered into a scheduled injection stream of treated groundwater as permitted in OP-1835 over a five to seven-hour period. This procedure would then be repeated on a consecutive second day. Alternatively, 5 kg of tracer may be added to each of ten 3,000-gallon tanks for a total of 30,000 gallons of tracer solution that may be injected independently of other injection flow over a period ofmore » up to five days. The permittees request that the types and masses of tracers that may be utilized per each injection well remain flexible enough to allow for one or more of the naphthalene sulfonate tracers to be substituted with a different naphthalene sulfonate. This need for flexibility is due to the availability of the tracers and any tracer listed that is designated for a given CrIN well may be interchanged with a tracer that is designated for another CrIN well, pending final NMED approval. The permittees are not allowed to introduce any new tracers and will submit a final work plan prior to each injection for each CrIN well.« less

  20. Oil industry first field trial of inter-well reservoir nanoagent tracers

    NASA Astrophysics Data System (ADS)

    Kanj, Mazen Y.; Kosynkin, Dmitry V.

    2015-05-01

    This short manuscript highlights the industry's first proven reservoir nanoagents' design and demonstrates a successful multi-well field trial using these agents. Our fundamental nanoparticles tracer template, A-Dots or Arab-D Dots, is intentionally geared towards the harsh but prolific Arab-D carbonate reservoir environment of 100+°C temperature, 150,000+ppm salinity, and an abundant presence of divalent ions in the connate water. Preliminary analyses confirmed nanoparticles' breakthrough at a producer nearly 500m from the injector at the reservoir level; thus, proving the tracer nanoparticles' mobility and transport capability. This is considered industry-first and a breakthrough achievement complementing earlier accomplishments in regard to the nanoagents' reservoir stability with the first successful single well test and ease of scale up with the synthesis of one metric ton of this material. The importance of this accomplishment is not in how sophisticated is the sensing functionalities of this design but rather in its stability, mobility, scalability, and field application potentials. This renders the concept of having active, reactive, and even communicative, in-situ reservoir nanoagents for underground sensing and intervention a well anticipated near-future reality.

  1. Effects of crude oil on water and tracer movement in the unsaturated and saturated zones.

    PubMed

    Delin, Geoffrey N; Herkelrath, William N

    2017-05-01

    A tracer test was conducted to aid in the investigation of water movement and solute transport at a crude-oil spill site near Bemidji, Minnesota. Time of travel was measured using breakthrough curves for rhodamine WT and bromide tracers moving from the soil surface through oil-contaminated and oil-free unsaturated zones to the saturated zone. Results indicate that the rates of tracer movement were similar in the oil-free unsaturated and saturated zones compared to the oily zones. These results are somewhat surprising given the oil contamination in the unsaturated and saturated zones. Rhodamine tracer breakthrough in the unsaturated and saturated zones in general was delayed in comparison to bromide tracer breakthrough. Peak tracer concentrations for the lysimeters and wells in the oily zone were much greater than at the corresponding depths in the oil-free zone. Water and tracer movement in the oily zone was complicated by soil hydrophobicity and decreased oil saturations toward the periphery of the oil. Preferential flow resulted in reduced tracer interaction with the soil, adsorption, and dispersion and faster tracer movement in the oily zone than expected. Tracers were freely transported through the oily zone to the water table. Recharge calculations support the idea that the oil does not substantially affect recharge in the oily zone. This is an important result indicating that previous model-based assumptions of decreased recharge beneath the oil were incorrect. Results have important implications for modeling the fate and transport of dissolved contaminants at hydrocarbon spill sites. Published by Elsevier B.V.

  2. In situ monitoring of tracer tests: how to distinguish tracer recovery from natural background

    NASA Astrophysics Data System (ADS)

    Bailly-Comte, V.; Durepaire, X.; Batiot-Guilhe, C.; Schnegg, P.-A.

    2018-03-01

    Hydrogeological tracer tests are primarily conducted with fluorescent tracers. Field fluorometers make it possible to monitor tracers at very low concentrations (<1 ppb) and at high frequency. However, changes in natural fluorescence at a site resulting from variations of dissolved and suspended inorganic and organic material may compromise the measurement of useful signals, thereby limiting the chances of identifying or quantifying the real tracer recovery. An elevated natural signal can mask small concentrations of the tracer while its variability can give the impression of a false recovery. This article shows how the use of a combination of several continuous measurements at different wavelengths allows a better extraction of the natural signal. Field multispectral fluorometers were installed at two Mediterranean karst outlets; both drain carbonate systems but have different environmental conditions. The fluorometers functioned over several hydrologic cycles, in periods affected or not by artificial tracers, making it possible to observe natural signal variations at these sites. The optical properties of this type of field fluorometer were used to calculate the spectral response of the different optics of the measuring probe. These responses, superimposed on three-dimensional excitation/emission matrices produced from laboratory fluorescence measurements, allowed an understanding of what the fluorometer sees under natural flow conditions. The result is an innovative method for correcting artificial tracer results. This type of correction makes it possible to fine-tune the effect of natural background variation on tracer recovery curves for a clear identification of the tracer presence and a more precise quantification of its recovery.

  3. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  4. A novel approach to the assess biotic oxygen consumption in marine sediment communities

    NASA Astrophysics Data System (ADS)

    Baranov, Victor; Queiros, Ana; Widdicombe, Stephen; Stephens, Nick; Lessin, Gennadi; Krause, Stefan; Lewandowski, Joerg

    2016-04-01

    Bioturbation , the mixing of the sediment matrix by burrowing animals impacts sediment metabolism, including respiration through redistribution of particulate organics, changes in bacterial biota diversity and acitivity, as well as via burrowing fauna's own metabolism. Bioturbation, reflecting faunal activity, is also a proxy for the general sedimentary ecosystem health, and can be impacted by many of emerging marine environmental issues such as ocean acidification, warming and the occurrence of heat waves. Sedimentary oxygen consumption is often taken as a proxy for the activity of bioturbating fauna, but determining baselines can be difficult because of the confounding effects of other fauna and microbes present in sediments, as well as irnorganic processes that consume oxygen. Limitations therefore exist in current methodologies, and numerous confounding factors are hampering progress in this area. Here, we present novel method for the assessment of sediment respiration which is expected to be affected only by the biogenic oxygen consumption (namely aerobic respiration). As long as tracer reduction "immune" to inorganic oxygen consumption, so that measurements using this method can be used, alongside traditional methods, to decouple biological respiration from inorganic oxygen consumption reactions. The tracer is easily detectable, non-toxic and can be applied in systems with constant oxygen supply. The latter allow for incubation without the need to to work with unsealed experimental units, bringing procedural advantage over traditional methods. Consequently assessed bioturbating fauna is not exposed to hypoxia and additional stress. Here, we had applied system for the first time to investigate impacts of a common North-Atlantic bioturbator, the brittle star Amphiura filiformis, - on respiration of marine sediments. Two series of experiments were conducted with animals and sediment collected from Cawsand Bay, Plymouth, UK Preliminary results show that tracer reduction was about 30% higher in bioturbated sediment than in defaunated controls, and the correlation between tracer reduction and oxygen consumption was high (r=0.92). This study allowed us to calculate the actual amount of oxygen consumed by organisms in the tanks excluding inorganic oxygen consumption, and access the effects of bioturbation on respiration of the marine muds. We believe that this tracer system can be successfully used for respiration assessment in the marine environment and to improve the assessment of respiration in burrowing infauna.

  5. Assessing vulnerability mapping and protection zones of karst spring waters and validating by the joint use of natural and artificial tracers. The case of Auta Spring (Southern Spain)

    NASA Astrophysics Data System (ADS)

    Marín, Ana Isabel; Mudarra, Matías; Andreo, Bartolomé

    2016-04-01

    Delineation of protection zones for water supply and implementation of proper land-use practices in surrounding areas are crucial aspects for a sustainable use of valuable drinking water resources. This is even more important in karst aquifers, which are particularly sensitive to contamination, having a very low self-cleaning capacity due to their structure and hydrological behavior. Consequently, specific methodologies adapted to the particular characteristics of karst media are necessary. In this work, an approach for protection zoning of the pilot site of Auta karst spring (southern Spain) is proposed, based on the application of COP+K method for contamination vulnerability and validation of results by natural (organic) tracers of infiltration (NO3-, TOC, intrinsic fluorescence) and by a dye tracer test conducted on June, 2011 (injecting 500 mg uranine). The aquifer drained by Auta spring (8.5 km2) presents a complex geological structure, formed by Jurassic dolostones and limestones highly folded and fractured. Recharge takes place by the infiltration of rainfall through karst landforms and also by losses in an adjacent river when it flows over the carbonate outcrops (dye injection point). Drainage is mainly through several springs located at the southwest, including Auta spring and 5 overflow springs. The source vulnerability map obtained by applying COP+K method can be adopted as the baseline to delineate the protection zones, through the conversion from vulnerability classes to degrees of protection. Dye tracer test and natural tracers of infiltration corroborate that aquifer sectors influenced by the river can be extremely vulnerable to pollution, but also well-developed exokarst features. In fact, slight evidences of pollution have been detected during the study period, with relatively-high NO3- contents and high fluorescence linked to bacteriological activity in Auta spring water. The jointly use of natural and artificial tracers constitute a reliable and effective procedure for validating vulnerability mapping of karst systems and springs used for water supply. This procedure is meant to implement and to complement protection zone mapping, particularly in countries lacking guidelines for protecting the water resources of karst aquifers.

  6. In vivo evaluation of [18F]FEAnGA-Me: a PET tracer for imaging β-glucuronidase (β-GUS) activity in a tumor/inflammation rodent model.

    PubMed

    Antunes, Inês F; Haisma, Hidde J; Elsinga, Philip H; Sijbesma, Jurgen W A; Waarde, Aren van; Willemsen, Antoon T M; Dierckx, Rudi A; de Vries, Erik F J

    2012-08-01

    The PET tracer, 1-O-(4-(2-fluoroethyl-carbamoyloxymethyl)-2-nitrophenyl)-O-β-d-glucopyronuronate ([(18)F]FEAnGA), was recently developed for PET imaging of extracellular β-glucuronidase (β-GUS). However, [(18)F]FEAnGA exhibited rapid renal clearance, which resulted in a relatively low tracer uptake in the tumor. To improve the pharmacokinetics of [(18)F]FEAnGA, we developed its more lipophilic methyl ester analog, [(18)F]FEAnGA-Me. [(18)F]FEAnGA-Me was obtained by alkylation of the O-protected glucuronide methyl ester precursor with [(18)F]-fluoroethylamine ([(18)F]FEA), followed by removal of the acetate protecting groups with NaOMe/MeOH. The PET tracer was evaluated by in vitro and in vivo studies. [(18)F]FEAnGA-Me was obtained in 5%-10% overall radiochemical yield. It is 10-fold less hydrophilic than [(18)F]FEAnGA and it is stable in PBS and in the presence of β-GUS for 1 h. However, in the presence of esterase or plasma [(18)F]FEAnGA-Me is converted to [(18)F]FEAnGA, and subsequently converted to [(18)F]FEA by β-GUS. MicroPET studies in Wistar rats bearing a C6 glioma and a sterile inflammation showed similar uptake in tumors after injection of either [(18)F]FEAnGA-Me or [(18)F]FEAnGA. Both tracers had a rapid two-phase clearance of total plasma radioactivity with a half-life of 1 and 8 min. The [(18)F]FEAnGA fraction generated from [(18)F]FEAnGA-Me by in vivo hydrolysis had a circulation half-life of 1 and 11 min in plasma. Similar distribution volume in the viable part of the tumor was found after injection of either [(18)F]FEAnGA-Me or [(18)F]FEAnGA. The imaging properties of [(18)F]FEAnGA-Me were not significantly better than those of [(18)F]FEAnGA. Therefore, other strategies should be applied in order to improve the kinetics of these tracers. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. The role of photographic parameters in laser speckle or particle image displacement velocimetry

    NASA Technical Reports Server (NTRS)

    Lourenco, L.; Krothapalli, A.

    1987-01-01

    The parameters involved in obtaining the multiple exposure photographs in the laser speckle velocimetry method (to record the light scattering by the seeding particles) were optimized. The effects of the type, concentration, and dimensions of the tracer, the exposure conditions (time between exposures, exposure time, and number of exposures), and the sensitivity and resolution of the film on the quality of the final results were investigated, photographing an experimental flow behind an impulsively started circular cylinder. The velocity data were acquired by digital processing of Young's fringes, produced by point-by-point scanning of a photographic negative. Using the optimal photographing conditions, the errors involved in the estimation of the fringe angle and spacing were of the order of 1 percent for the spacing and +/1 deg for the fringe orientation. The resulting accuracy in the velocity was of the order of 2-3 percent of the maximum velocity in the field.

  8. Optimization of spectroscopic surveys for testing non-Gaussianity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raccanelli, Alvise; Doré, Olivier; Dalal, Neal, E-mail: alvise@caltech.edu, E-mail: Olivier.P.Dore@jpl.nasa.gov, E-mail: dalaln@illinois.edu

    We investigate optimization strategies to measure primordial non-Gaussianity with future spectroscopic surveys. We forecast measurements coming from the 3D galaxy power spectrum and compute constraints on primordial non-Gaussianity parameters f{sub NL} and n{sub NG}. After studying the dependence on those parameters upon survey specifications such as redshift range, area, number density, we assume a reference mock survey and investigate the trade-off between number density and area surveyed. We then define the observational requirements to reach the detection of f{sub NL} of order 1. Our results show that power spectrum constraints on non-Gaussianity from future spectroscopic surveys can improve on currentmore » CMB limits, but the multi-tracer technique and higher order correlations will be needed in order to reach an even better precision in the measurements of the non-Gaussianity parameter f{sub NL}.« less

  9. Quantitative multimodality imaging in cancer research and therapy.

    PubMed

    Yankeelov, Thomas E; Abramson, Richard G; Quarles, C Chad

    2014-11-01

    Advances in hardware and software have enabled the realization of clinically feasible, quantitative multimodality imaging of tissue pathophysiology. Earlier efforts relating to multimodality imaging of cancer have focused on the integration of anatomical and functional characteristics, such as PET-CT and single-photon emission CT (SPECT-CT), whereas more-recent advances and applications have involved the integration of multiple quantitative, functional measurements (for example, multiple PET tracers, varied MRI contrast mechanisms, and PET-MRI), thereby providing a more-comprehensive characterization of the tumour phenotype. The enormous amount of complementary quantitative data generated by such studies is beginning to offer unique insights into opportunities to optimize care for individual patients. Although important technical optimization and improved biological interpretation of multimodality imaging findings are needed, this approach can already be applied informatively in clinical trials of cancer therapeutics using existing tools. These concepts are discussed herein.

  10. Amyloid-β Plaques in Clinical Alzheimer’s Disease Brain Incorporate Stable Isotope Tracer In Vivo and Exhibit Nanoscale Heterogeneity

    PubMed Central

    Wildburger, Norelle C.; Gyngard, Frank; Guillermier, Christelle; Patterson, Bruce W.; Elbert, Donald; Mawuenyega, Kwasi G.; Schneider, Theresa; Green, Karen; Roth, Robyn; Schmidt, Robert E.; Cairns, Nigel J.; Benzinger, Tammie L. S.; Steinhauser, Matthew L.; Bateman, Randall J.

    2018-01-01

    Alzheimer’s disease (AD) is a neurodegenerative disorder with clinical manifestations of progressive memory decline and loss of executive function and language. AD affects an estimated 5.3 million Americans alone and is the most common form of age-related dementia with a rapidly growing prevalence among the aging population—those 65 years of age or older. AD is characterized by accumulation of aggregated amyloid-beta (Aβ) in the brain, which leads to one of the pathological hallmarks of AD—Aβ plaques. As a result, Aβ plaques have been extensively studied after being first described over a century ago. Advances in brain imaging and quantitative measures of Aβ in biological fluids have yielded insight into the time course of plaque development decades before and after AD symptom onset. However, despite the fundamental role of Aβ plaques in AD, in vivo measures of individual plaque growth, growth distribution, and dynamics are still lacking. To address this question, we combined stable isotope labeling kinetics (SILK) and nanoscale secondary ion mass spectrometry (NanoSIMS) imaging in an approach termed SILK–SIMS to resolve plaque dynamics in three human AD brains. In human AD brain, plaques exhibit incorporation of a stable isotope tracer. Tracer enrichment was highly variable between plaques and the spatial distribution asymmetric with both quiescent and active nanometer sub-regions of tracer incorporation. These data reveal that Aβ plaques are dynamic structures with deposition rates over days indicating a highly active process. Here, we report the first, direct quantitative measures of in vivo deposition into plaques in human AD brain. Our SILK–SIMS studies will provide invaluable information on plaque dynamics in the normal and diseased brain and offer many new avenues for investigation into pathological mechanisms of the disease, with implications for therapeutic development. PMID:29623063

  11. Amyloid-β Plaques in Clinical Alzheimer's Disease Brain Incorporate Stable Isotope Tracer In Vivo and Exhibit Nanoscale Heterogeneity.

    PubMed

    Wildburger, Norelle C; Gyngard, Frank; Guillermier, Christelle; Patterson, Bruce W; Elbert, Donald; Mawuenyega, Kwasi G; Schneider, Theresa; Green, Karen; Roth, Robyn; Schmidt, Robert E; Cairns, Nigel J; Benzinger, Tammie L S; Steinhauser, Matthew L; Bateman, Randall J

    2018-01-01

    Alzheimer's disease (AD) is a neurodegenerative disorder with clinical manifestations of progressive memory decline and loss of executive function and language. AD affects an estimated 5.3 million Americans alone and is the most common form of age-related dementia with a rapidly growing prevalence among the aging population-those 65 years of age or older. AD is characterized by accumulation of aggregated amyloid-beta (Aβ) in the brain, which leads to one of the pathological hallmarks of AD-Aβ plaques. As a result, Aβ plaques have been extensively studied after being first described over a century ago. Advances in brain imaging and quantitative measures of Aβ in biological fluids have yielded insight into the time course of plaque development decades before and after AD symptom onset. However, despite the fundamental role of Aβ plaques in AD, in vivo measures of individual plaque growth, growth distribution, and dynamics are still lacking. To address this question, we combined stable isotope labeling kinetics (SILK) and nanoscale secondary ion mass spectrometry (NanoSIMS) imaging in an approach termed SILK-SIMS to resolve plaque dynamics in three human AD brains. In human AD brain, plaques exhibit incorporation of a stable isotope tracer. Tracer enrichment was highly variable between plaques and the spatial distribution asymmetric with both quiescent and active nanometer sub-regions of tracer incorporation. These data reveal that Aβ plaques are dynamic structures with deposition rates over days indicating a highly active process. Here, we report the first, direct quantitative measures of in vivo deposition into plaques in human AD brain. Our SILK-SIMS studies will provide invaluable information on plaque dynamics in the normal and diseased brain and offer many new avenues for investigation into pathological mechanisms of the disease, with implications for therapeutic development.

  12. Comparative evaluation of two glycine transporter 1 radiotracers [11C]GSK931145 and [18F]MK-6577 in baboons.

    PubMed

    Zheng, Ming-Qiang; Lin, Shu-Fei; Holden, Daniel; Naganawa, Mika; Ropchan, Jim R; Najafzaden, Soheila; Kapinos, Michael; Tabriz, Mike; Carson, Richard E; Hamill, Terence G; Huang, Yiyun

    2016-03-01

    Glycine transporter type-1 (GlyT1) has been proposed as a target for drug development for schizophrenia. PET imaging with a GlyT1 specific radiotracer will allow for the measurement of target occupancy of GlyT1 inhibitors, and for in vivo investigation of GlyT1 alterations in schizophrenia. We conducted a comparative evaluation of two GlyT1 radiotracers, [(11) C]GSK931145, and [(18) F]MK-6577, in baboons. Two baboons were imaged with [(11) C]GSK931145 and [(18) F]MK-6577. Blocking studies with GSK931145 (0.3 or 0.2 mg/kg) were conducted to determine the level of tracer specific binding. [(11) C]GSK931145 and [(18) F]MK-6577 were synthesized in good yield and high specific activity. Moderately fast metabolism was observed for both tracers, with ∼ 30% of parent at 30 min post-injection. In the brain, both radiotracers showed good uptake and distribution profiles consistent with regional GlyT1 densities. [(18) F]MK-6577 displayed higher uptake and faster kinetics than [(11) C]GSK931145. Time activity curves were well described by the two-tissue compartment model. Regional volume of distribution (VT ) values were higher for [(18) F]MK-6577 than [(11) C]GSK931145. Pretreatment with GSK931145 reduced tracer uptake to a homogeneous level throughout the brain, indicating in vivo binding specificity and lack of a reference region for both radiotracers. Linear regression analysis of VT estimates between tracers indicated higher specific binding for [(18) F]MK-6577 than [(11) C]GSK931145, consistent with higher regional binding potential (BPND ) values of [(18) F]MK-6577 calculated using VT from the baseline scans and non-displaceable distribution volume (VND ) derived from blocking studies. [(18) F]MK-6577 appears to be a superior radiotracer with higher brain uptake, faster kinetics, and higher specific binding signals than [(11) C]GSK931145. © 2016 Wiley Periodicals, Inc.

  13. Transient storage assessments of dye-tracer injections in rivers of the Willamette Basin, Oregon

    USGS Publications Warehouse

    Laenen, A.; Bencala, K.E.

    2001-01-01

    Rhodamine WT dye-tracer injections in rivers of the Willamette Basin yield concentration-time curves with characteristically long recession times suggestive of active transient storage processes. The scale of drainage areas contributing to the stream reaches studied in the Willamette Basin ranges from 10 to 12,000 km2. A transient storage assessment of the tracer studies has been completed using the U.S. Geological Survey's One-dimensional Transport with Inflow and Storage (OTIS) model, which incorporates storage exchange and decay functions along with the traditional dispersion and advection transport equation. The analysis estimates solute transport of the dye. It identifies first-order decay coefficients to be on the order of 10-5/sec for the nonconservative Rhodamine WT. On an individual subreach basis, the first-order decay is slower (typically by an order of magnitude) than the transient storage process, indicating that nonconservative tracers may be used to evaluate transient storage in rivers. In the transient storage analysis, a dimensionless parameter (As/A) expresses the spatial extent of storage zone area relative to stream cross section. In certain reaches of Willamette Basin pool-and-riffle, gravel-bed rivers, this parameter was as large as 0.5. A measure of the storage exchange flux was calculated for each stream subreach in the simulation analysis. This storage exchange is shown subjectively to be higher at higher stream discharges. Hyporheic linkage between streams and subsurface flows is the probable physical mechanism contributing to a significant part of this inferred active transient storage. Hyporheic linkages are further suggested by detailed measurements of river discharge with an Acoustic Doppler Current Profiler system delineating zones in two large rivers where water alternately enters and leaves the surface channels through graveland-cobble riverbeds. Measurements show patterns of hyporheic exchange that are highly variable in time and space.

  14. Advances in evaluation of primary brain tumors.

    PubMed

    Chen, Wei; Silverman, Daniel H S

    2008-07-01

    The evaluation of primary brain tumor is challenging. Neuroimaging plays a significant role. At diagnosis, imaging is needed to establish a differential diagnosis, provide prognostic information, as well as direct biopsy. After the initial treatment, imaging is needed to distinguish recurrent disease from treatment-related changes such as radiation necrosis. In low-grade gliomas, this also includes monitoring anaplastic transformation into high-grade tumors. Recently, targeted treatments have been an extremely active area of research. Evaluation in clinical trials of such targeted treatments demands advanced roles of imaging such as treatment planning, monitoring response, and predicting treatment outcomes. Current clinical gold standard magnetic resonance imaging provides superior structural detail but poor specificity in identifying viable tumors in treated brain with surgery/radiation/chemotherapy. (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) is capable of identifying anaplastic transformation and has prognostic value. The sensitivity and specificity of FDG in evaluating recurrent tumor and treatment-induced changes can be significantly improved by coregistration with magnetic resonance imaging and potentially by delayed imaging 3 to 8 hours after injection. Amino acid PET tracers can be more sensitive than FDG in imaging some recurrent tumors, in particular recurrent low-grade tumors. They are also promising for differentiating between recurrent tumors and treatment-induced changes. Newer PET tracers to image important aspects of tumor biology have been actively studied. Tracers for imaging membrane transport such as (18)F-choline have shown promise in differential diagnosis. (18)F-labeled nucleotide analogs such as 3'-deoxy-3'-[(18)F]-fluorothymidine (FLT) and (18)F-FMAU have been developed to image proliferation. The use of FLT has demonstrated prognostic power in predicting treatment response in patients treated with an antiangiogenic agent. Tracers for imaging hypoxia such as (18)F-FMISO have been studied and appear promising in providing prognostic information as well as planning treatment.

  15. Helium as a Dynamical Tracer in the Thermosphere

    NASA Astrophysics Data System (ADS)

    Thayer, J. P.; Liu, X.; Wang, W.; Burns, A. G.

    2014-12-01

    Helium has been a missing constituent in current thermosphere general circulation models. Although typically a minor gas relative to the more abundant major gasses, its unique properties of being chemically inert and light make it an excellent tracer of thermosphere dynamics. Studying helium can help simplify understanding of transport effects. This understanding can then be projected to other gasses whose overall structure and behavior are complex but, by contrasting with helium, can be evaluated for its transport dependencies. The dynamical influences on composition impact estimates of thermosphere mass density, where helium during solar minima can have a direct contribution, as well as ionosphere electron density. Furthermore, helium estimates in the upper thermosphere during solar minima have not been observed since the 1976 minimum. Indirect estimates of helium in the upper thermosphere during the recent extreme solar minimum indicates winter-time helium concentrations exceeded NRL-MSISE00 estimates by 30%-70% during periods of quiet geomagnetic activity. For times of active geomagnetic conditions, helium concentrations near ~450 km altitude are estimated to decrease while oxygen concentrations increase. An investigation of the altitude structure in thermosphere mass density storm-time perturbations reveal the important effects of composition change with maximum perturbation occurring near the He/O transition region and a much weaker maximum occurring near the O/N2 transition region. However, evaluating helium behavior and its role as a dynamical tracer is not straightforward and model development is necessary to adequately establish the connection to specific dynamical processes. Fortunately recent efforts have led to the implementation of helium modules in the NCAR TIEGCM and TIME-GCM. In this invited talk, the simulated helium behavior and structure will be shown to reproduce observations (such as the wintertime helium bulge and storm-time response) and its utility as a dynamical tracer of thermosphere dynamics will be elucidated.

  16. PROXIMA CENTAURI AS A BENCHMARK FOR STELLAR ACTIVITY INDICATORS IN THE NEAR-INFRARED

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, Paul; Bender, Chad; Mahadevan, Suvrath

    A new generation of dedicated Doppler spectrographs will attempt to detect low-mass exoplanets around mid- to late M stars at near-infrared (NIR) wavelengths, where those stars are brightest and have the most Doppler information content. A central requirement for the success of these instruments is to properly measure the component of radial velocity (RV) variability contributed by stellar magnetic activity and to account for it in exoplanet models of RV data. The wavelength coverage for many of these new instruments will not include the Ca ii H and K or H α  lines, the most frequently used absorption-line tracers of magneticmore » activity. Thus, it is necessary to define and characterize NIR activity indicators for mid- to late M stars in order to provide simultaneous activity metrics for NIR RV data. We have used the high-cadence UVES observations of the M5.5 dwarf Proxima Centauri from Fuhrmeister et al. to compare the activity sensitivity of eight NIR atomic lines to that of H α . We find that equivalent-width-type measurements of the NIR K i doublet and the Ca ii NIR triplet are excellent proxies for the canonical optical tracers. The Ca ii triplet will be acquired by most of the new and upcoming NIR Doppler spectrographs, offering a common, reliable indicator of activity.« less

  17. Transport and dispersion of fluorescent tracer particles for the dune-bed condition, Atrisco Feeder Canal near Bernalillo, New Mexico

    USGS Publications Warehouse

    Rathbun, R.E.; Kennedy, Vance C.

    1978-01-01

    A fluorescent tracer technique was used to study the rates of transport and dispersion of sediment particles of various diameters and specific gravities for a dune-bed condition in an alluvial channel, Atrisco Feeder Canal near Bernalillo, N. Mex. The total transport rates of bed material measured by the steady-dilution and spatial-integration procedures were within the range of transport rates computed by the modified Einstein procedure. Lateral dispersion of the tracer particles increased with increase in the size of the tracer particles, whereas longitudinal dispersion decreased. The velocities of the tracer particles decreased with increase in the size of the tracer particles; dependence on particle diameter was large for the small particles, small for the large particles. Tracers were found at larger depths in the bed than would be expected on the basis of the sizes of the dunes in the channel. (Woodard-USGS)

  18. Determination of stream reaeration coefficients by use of tracers

    USGS Publications Warehouse

    Kilpatrick, F.A.; Rathbun, R.E.; Yotsukura, N.; Parker, G.W.; DeLong, L.L.

    1987-01-01

    Stream reaeration is the physical absorption of oxygen from the atmosphere by a flowing stream. This is the primary process by which a stream replenishes the oxygen consumed in the biodegradation of organic wastes.Prior to 1965, reaeration rate coefficients could be estimated only by indirect methods. In 1965, a direct method of measuring stream reaeration coefficients was developed in which a radioactive tracer gas was injected into a stream--the tracer gas being desorbed from the stream inversely to how oxygen would be absorbed. The technique has since been modified by substituting hydrocarbon gases for the radioactive tracer gas.This manual describes the slug-injection and constant-rate injection methods of performing gas-tracer desorption measurements. Emphasis is on the use of rhodamine WT dye as a relatively conservative tracer and propane as the nonconservative gas tracer, on planning field tests, methods of injection, sampling and analysis, and computational techniques to compute desorption and reaeration coefficients.

  19. Neutrally buoyant tracers in hydrogeophysics: Field demonstration in fractured rock

    NASA Astrophysics Data System (ADS)

    Shakas, Alexis; Linde, Niklas; Baron, Ludovic; Selker, John; Gerard, Marie-Françoise; Lavenant, Nicolas; Bour, Olivier; Le Borgne, Tanguy

    2017-04-01

    Electrical and electromagnetic methods are extensively used to map electrically conductive tracers within hydrogeologic systems. Often, the tracers used consist of dissolved salt in water, leading to a denser mixture than the ambient formation water. Density effects are often ignored and rarely modeled but can dramatically affect transport behavior and introduce dynamics that are unrepresentative of the response obtained with classical tracers (e.g., uranine). We introduce a neutrally buoyant tracer consisting of a mixture of salt, water, and ethanol and monitor its movement during push-pull experiments in a fractured rock aquifer using ground-penetrating radar. Our results indicate a largely reversible transport process and agree with uranine-based push-pull experiments at the site, which is in contrast to results obtained using dense saline tracers. We argue that a shift toward neutrally buoyant tracers in both porous and fractured media would advance hydrogeophysical research and enhance its utility in hydrogeology.

  20. Modified expression for bulb-tracer depletion—Effect on argon dating standards

    USGS Publications Warehouse

    Fleck, Robert J.; Calvert, Andrew T.

    2014-01-01

    40Ar/39Ar geochronology depends critically on well-calibrated standards, often traceable to first-principles K-Ar age calibrations using bulb-tracer systems. Tracer systems also provide precise standards for noble-gas studies and interlaboratory calibration. The exponential expression long used for calculating isotope tracer concentrations in K-Ar age dating and calibration of 40Ar/39Ar age standards may provide a close approximation of those values, but is not correct. Appropriate equations are derived that accurately describe the depletion of tracer reservoirs and concentrations of sequential tracers. In the modified expression the depletion constant is not in the exponent, which only varies as integers by tracer-number. Evaluation of the expressions demonstrates that systematic error introduced through use of the original expression may be substantial where reservoir volumes are small and resulting depletion constants are large. Traditional use of large reservoir to tracer volumes and the resulting small depletion constants have kept errors well less than experimental uncertainties in most previous K-Ar and calibration studies. Use of the proper expression, however, permits use of volumes appropriate to the problems addressed.

  1. Evaluation of sediment transport at a fetch-limited beach from spring to neap tide

    NASA Astrophysics Data System (ADS)

    Carrasco, Ana Rita; Ferreira, Óscar; Matias, Ana; Freire, Paula; Alveirinho Dias, João.

    2010-05-01

    Sediment transport studies are useful tools for the determination of sediment budgets, important in the definition of management policies, in particular in environments not fully understood like fetch-limited beaches. Only a few studies have been made with respect to these beaches, and research efforts need to be continued to correctly quantify the main factors governing morphological changes. The present study provides new insights on sediment transport at a fetch-limited backbarrier beach located at the Peninsula do Ancão (Ria Formosa, South of Portugal). The field site extends over ~150 m and includes a sandy beach with a low and narrow reflective morphology, and an external sand bank at the seaward edge of the sub-aerial beach profile. Fluorescent tracers were used to measure the short-term sediment transport (rates and directions) from spring to neap tides, for fair-weather conditions. The experiment was set at two beach morphologies: beach face and sand bank. Tracer was released on 20th March 2008 at both sites, and sampling was conducted at low tide, each 24h, during 7 days. In situ fluorescent tracer detection was performed with UV light. Currents were obtained with a portable single-axis electromagnetic current meter located at the beach face, and an Aquadopp Profiler located at the sand bank. Local waves were obtained by numerical modelling for the study area, based on prevailing winds (measured by a nearby meteorological station), and using available bathymetric surveys. Tracer trends, tidal currents, wind conditions and waves were integrative in order to determine to which forcing mechanism the beach morphology was more responsive. Daily wind intensities were, in average, close to 5 m/s, and maximum estimated significant wave height (Hs) did not exceed 0.045 m. Daily mean wave period ranged from 0.5 s to 0.7 s. The maximum tidal range was 2.8 m. Currents were of higher magnitude at the sand bank than at the beach face, with the maximum during ebb tide (0.50 m/s). At the beach face, maximum velocities are very similar for both ebb and flood tide, with a maximum of 0.26 m/s. Tracer displacement was greater at the beach face, indicating that this is the most active part of the profile during the experiment. At the sand bank, tracer dispersion was greater, but tracer advection was shorter. Tracer isopachs illustrate a relatively independency of both analysed morphologies, without significant exchange across the profile. At both morphologies, the residual transport is dominated by the longshore component, and mostly directed towards the ebb. Ebb directed transport agrees with ebb dominance on tidal currents at this location. Results suggest a tidal and current dominance. Tidal range assumes particular importance at beach face.

  2. Impact of polymer surface characteristics on the microrheological measurement quality of protein solutions - A tracer particle screening.

    PubMed

    Bauer, Katharina Christin; Schermeyer, Marie-Therese; Seidel, Jonathan; Hubbuch, Jürgen

    2016-05-30

    Microrheological measurements prove to be suitable to identify rheological parameters of biopharmaceutical solutions. These give information about the flow characteristics but also about the interactions and network structures in protein solutions. For the microrheological measurement tracer particles are required. Due to their specific surface characteristic not all are suitable for reliable measurement results in biopharmaceutical systems. In the present work a screening of melamine, PMMA, polystyrene and surface modified polystyrene as tracer particles were investigated at various protein solution conditions. The surface characteristics of the screened tracer particles were evaluated by zeta potential measurements. Furthermore each tracer particle was used to determine the dynamic viscosity of lysozyme solutions by microrheology and compared to a standard. The results indicate that the selection of the tracer particle had a strong impact on the quality of the microrheological measurement dependent on pH and additive type. Surface modified polystyrene was the only tracer particle that yielded good microrheological results for all tested conditions. The study indicated that the electrostatic surface charge of the tracer particle had a minor impact than its hydrophobicity. This characteristic was the crucial surface property that needs to be considered for the selection of a suitable tracer particle to achieve high measurement accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Prediction of down-gradient impacts of DNAPL source depletion using tracer techniques: Laboratory and modeling validation

    NASA Astrophysics Data System (ADS)

    Jawitz, J. W.; Basu, N.; Chen, X.

    2007-05-01

    Interwell application of coupled nonreactive and reactive tracers through aquifer contaminant source zones enables quantitative characterization of aquifer heterogeneity and contaminant architecture. Parameters obtained from tracer tests are presented here in a Lagrangian framework that can be used to predict the dissolution of nonaqueous phase liquid (NAPL) contaminants. Nonreactive tracers are commonly used to provide information about travel time distributions in hydrologic systems. Reactive tracers have more recently been introduced as a tool to quantify the amount of NAPL contaminant present within the tracer swept volume. Our group has extended reactive tracer techniques to also characterize NAPL spatial distribution heterogeneity. By conceptualizing the flow field through an aquifer as a collection of streamtubes, the aquifer hydrodynamic heterogeneities may be characterized by a nonreactive tracer travel time distribution, and NAPL spatial distribution heterogeneity may be similarly described using reactive travel time distributions. The combined statistics of these distributions are used to derive a simple analytical solution for contaminant dissolution. This analytical solution, and the tracer techniques used for its parameterization, were validated both numerically and experimentally. Illustrative applications are presented from numerical simulations using the multiphase flow and transport simulator UTCHEM, and laboratory experiments of surfactant-enhanced NAPL remediation in two-dimensional flow chambers.

  4. Soil radon measurements as a potential tracer of tectonic and volcanic activity.

    PubMed

    Neri, Marco; Ferrera, Elisabetta; Giammanco, Salvatore; Currenti, Gilda; Cirrincione, Rosolino; Patanè, Giuseppe; Zanon, Vittorio

    2016-04-15

    In Earth Sciences there is a growing interest in studies concerning soil-radon activity, due to its potential as a tracer of numerous natural phenomena. Our work marks an advance in the comprehension of the interplay between tectonic activity, volcanic eruptions and gas release through faults. Soil-radon measurements, acquired on Mt. Etna volcano in 2009-2011, were analyzed. Our radon probe is sensitive to changes in both volcanic and seismic activity. Radon data were reviewed in light of the meteorological parameters. Soil samples were analyzed to characterize their uranium content. All data have been summarized in a physical model which identifies the radon sources, highlights the mechanism of radon transport and envisages how such a mechanism may change as a consequence of seismicity and volcanic events. In the NE of Etna, radon is released mainly from a depth of <1400 m, with an ascent speed of >50 m/day. Three periods of anomalous gas release were found (February 2010, January and February 2011). The trigger of the first anomaly was tectonic, while the second and third had a volcanic origin. These results mark a significant step towards a better understanding of the endogenous mechanisms that cause changes in soil-radon emission at active volcanoes.

  5. Soil radon measurements as a potential tracer of tectonic and volcanic activity

    NASA Astrophysics Data System (ADS)

    Neri, Marco; Ferrera, Elisabetta; Giammanco, Salvatore; Currenti, Gilda; Cirrincione, Rosolino; Patanè, Giuseppe; Zanon, Vittorio

    2016-04-01

    In Earth Sciences there is a growing interest in studies concerning soil-radon activity, due to its potential as a tracer of numerous natural phenomena. Our work marks an advance in the comprehension of the interplay between tectonic activity, volcanic eruptions and gas release through faults. Soil-radon measurements, acquired on Mt. Etna volcano in 2009-2011, were analyzed. Our radon probe is sensitive to changes in both volcanic and seismic activity. Radon data were reviewed in light of the meteorological parameters. Soil samples were analyzed to characterize their uranium content. All data have been summarized in a physical model which identifies the radon sources, highlights the mechanism of radon transport and envisages how such a mechanism may change as a consequence of seismicity and volcanic events. In the NE of Etna, radon is released mainly from a depth of <1400 m, with an ascent speed of >50 m/day. Three periods of anomalous gas release were found (February 2010, January and February 2011). The trigger of the first anomaly was tectonic, while the second and third had a volcanic origin. These results mark a significant step towards a better understanding of the endogenous mechanisms that cause changes in soil-radon emission at active volcanoes.

  6. Soil radon measurements as a potential tracer of tectonic and volcanic activity

    PubMed Central

    Neri, Marco; Ferrera, Elisabetta; Giammanco, Salvatore; Currenti, Gilda; Cirrincione, Rosolino; Patanè, Giuseppe; Zanon, Vittorio

    2016-01-01

    In Earth Sciences there is a growing interest in studies concerning soil-radon activity, due to its potential as a tracer of numerous natural phenomena. Our work marks an advance in the comprehension of the interplay between tectonic activity, volcanic eruptions and gas release through faults. Soil-radon measurements, acquired on Mt. Etna volcano in 2009–2011, were analyzed. Our radon probe is sensitive to changes in both volcanic and seismic activity. Radon data were reviewed in light of the meteorological parameters. Soil samples were analyzed to characterize their uranium content. All data have been summarized in a physical model which identifies the radon sources, highlights the mechanism of radon transport and envisages how such a mechanism may change as a consequence of seismicity and volcanic events. In the NE of Etna, radon is released mainly from a depth of <1400 m, with an ascent speed of >50 m/day. Three periods of anomalous gas release were found (February 2010, January and February 2011). The trigger of the first anomaly was tectonic, while the second and third had a volcanic origin. These results mark a significant step towards a better understanding of the endogenous mechanisms that cause changes in soil-radon emission at active volcanoes. PMID:27079264

  7. Quantification of 18F-JNJ-42259152, a novel phosphodiesterase 10A PET tracer: kinetic modeling and test-retest study in human brain.

    PubMed

    Van Laere, Koen; Ahmad, Rawaha U; Hudyana, Hendra; Dubois, Kristof; Schmidt, Mark E; Celen, Sofie; Bormans, Guy; Koole, Michel

    2013-08-01

    Phosphodiesterase 10A (PDE10A) plays a central role in striatal signaling and is implicated in several neuropsychiatric disorders, such as movement disorders and schizophrenia. We performed initial brain kinetic modeling of the novel PDE10A tracer (18)F-JNJ-42259152 (2-[[4-[1-(2-(18)F-fluoroethyl)-4-(4-pyridinyl)-1H-pyrazol-3-yl]phenoxy]methyl]-3,5-dimethyl-pyridine) and studied test-retest reproducibility in healthy volunteers. Twelve healthy volunteers (5 men, 7 women; age range, 42-77 y) were scanned dynamically up to 135 min after bolus injection of 172.5 ± 10.3 MBq of (18)F-JNJ42259152. Four volunteers (2 men, 2 women) underwent retest scanning, with a mean interscan interval of 37 d. Input functions and tracer parent fractions were determined using arterial sampling and high-performance liquid chromatography analysis. Volumes of interest for the putamen, caudate nucleus, ventral striatum, substantia nigra, thalamus, frontal cortex, and cerebellum were delineated using individual volumetric T1 MR imaging scans. One-tissue (1T) and 2-tissue (2T) models were evaluated to calculate total distribution volume (VT). Simplified models were also tested to calculate binding potential (BPND), including the simplified reference tissue model (SRTM) and multilinear reference tissue model, using the frontal cortex as the optimal reference tissue. The stability of VT and BPND was assessed down to a 60-min scan time. The average intact tracer half-life in blood was 90 min. The 2T model VT values for the putamen, caudate nucleus, ventral striatum, substantia nigra, thalamus, frontal cortex, and cerebellum were 1.54 ± 0.37, 0.90 ± 0.24, 0.64 ± 0.18, 0.42 ± 0.09, 0.35 ± 0.09, 0.30 ± 0.07, and 0.36 ± 0.12, respectively. The 1T model provided significantly lower VT values, which were well correlated to the 2T VT. SRTM BPND values referenced to the frontal cortex were 3.45 ± 0.43, 1.78 ± 0.35, 1.10 ± 0.31, and 0.44 ± 0.09 for the respective target regions putamen, caudate nucleus, ventral striatum, and substantia nigra, with similar values for the multilinear reference tissue model. Good correlations were found for the target regions putamen, caudate nucleus, ventral striatum, and substantia nigra between the 2T-compartment model BPND and the SRTM BPND (r = 0.57, 0.82, 0.70, and 0.64, respectively). SRTM BPND using a 90- and 60-min acquisition interval showed low bias. Test-retest variability was 5%-19% for 2T VT and 5%-12% for BPND SRTM. Kinetic modeling of (18)F-JNJ-42259152 shows that PDE10A activity can be reliably quantified and simplified using a reference tissue model with the frontal cortex as reference and a 60-min acquisition period.

  8. Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruijf, Willy J.M. de, E-mail: kruijf.de.w@bvi.nl; Verstraete, Jan; Neustadter, David

    2013-02-01

    Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performedmore » to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.« less

  9. Patient positioning based on a radioactive tracer implanted in patients with localized prostate cancer: a performance and safety evaluation.

    PubMed

    de Kruijf, Willy J M; Verstraete, Jan; Neustadter, David; Corn, Benjamin W; Hol, Sandra; Venselaar, Jack L M; Davits, Rob J; Wijsman, Bart P; Van den Bergh, Laura; Budiharto, Tom; Oyen, Raymond; Haustermans, Karin; Poortmans, Philip M P

    2013-02-01

    To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ((192)Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. A novel approach for quantitative harmonization in PET.

    PubMed

    Namías, M; Bradshaw, T; Menezes, V O; Machado, M A D; Jeraj, R

    2018-05-04

    Positron emission tomography (PET) imaging allows for measurement of activity concentrations of a given radiotracer in vivo. The quantitative capabilities of PET imaging are particularly important in the context of monitoring response to treatment, where quantitative changes in tracer uptake could be used as a biomarker of treatment response. Reconstruction algorithms and settings have a significant impact on PET quantification. In this work we introduce a novel harmonization methodology requiring only a simple cylindrical phantom and show that it can match the performance of more complex harmonization approaches based on phantoms with spherical inserts. Resolution and noise measurements from cylindrical phantoms are used to simulate the spherical inserts from NEMA image quality phantoms. An optimization algorithm was used to find the optimal smoothing filters for the simulated NEMA phantom images to identify those that best harmonized the PET scanners. Our methodology was tested on seven different PET models from two manufacturers installed at five institutions. Our methodology is able to predict contrast recovery coefficients (CRCs) from NEMA phantoms with errors within  ±5.2% for CRCmax and  ±3.7% for CRCmean (limits of agreement  =  95%). After applying the proposed harmonization protocol, all the CRC values were within the tolerances from EANM. Quantitative harmonization in compliance with the EARL FDG-PET/CT accreditation program is achieved in a simpler way, without the need of NEMA phantoms. This may lead to simplified scanner harmonization workflows more accessible to smaller institutions.

  11. Tracer element for indoor PM2.5 in China migrated from outdoor

    NASA Astrophysics Data System (ADS)

    Ji, Wenjing; Li, Hongyu; Zhao, Bin; Deng, Furong

    2018-03-01

    Sulfur and nickel have been widely used as tracers of outdoor PM2.5 (particulate matter with an aerodynamic diameter ≤ 2.5 μm) in the United States and Europe; however, their feasibility as tracers has not been verified yet in China. We aim to verify whether sulfur or nickel could be used as a tracer element and, if not, to identify a suitable tracer element for outdoor PM2.5 in China. We conduct two types of experiments, namely, preliminary and main-study experiments. We analyze 102 pairs of indoor and outdoor PM2.5 samples in Beijing. The correlation between the I/O (indoor/outdoor) ratio of an element and the I/O ratio of total PM2.5 is one of the criteria used to test whether this element can be used as a tracer element. The average concentrations of nickel are found to be below the detection limits in both preliminary and main-study tests. Thus, nickel cannot be used as a tracer element in China. Based on the correlations of elemental I/O ratios and the I/O ratio of total PM2.5 in the preliminary and main-study tests, sulfur also cannot be used as a tracer element; however, it should be feasible to use iron as a tracer element in Beijing according to the test results. The estimated infiltration factor obtained by using iron as tracer is extremely consistent with the calculations based on the mass balance model. In summary, iron is found to be more suitable as a tracer for outdoor PM2.5 in Beijing than sulfur or nickel.

  12. Multiple injected and natural conservative tracers quantify mixing in a stream confluence affected by acid mine drainage near Silverton, Colorado

    NASA Astrophysics Data System (ADS)

    Schemel, Laurence E.; Cox, Marisa H.; Runkel, Robert L.; Kimball, Briant A.

    2006-08-01

    The acidic discharge from Cement Creek, containing elevated concentrations of dissolved metals and sulphate, mixed with the circumneutral-pH Animas River over a several hundred metre reach (mixing zone) near Silverton, CO, during this study. Differences in concentrations of Ca, Mg, Si, Sr, and SO42- between the creek and the river were sufficiently large for these analytes to be used as natural tracers in the mixing zone. In addition, a sodium chloride (NaCl) tracer was injected into Cement Creek, which provided a Cl- reference tracer in the mixing zone. Conservative transport of the dissolved metals and sulphate through the mixing zone was verified by mass balances and by linear mixing plots relative to the injected reference tracer. At each of seven sites in the mixing zone, five samples were collected at evenly spaced increments of the observed across-channel gradients, as determined by specific conductance. This created sets of samples that adequately covered the ranges of mixtures (mixing ratios, in terms of the fraction of Animas River water, %AR). Concentratis measured in each mixing zone sample and in the upstream Animas River and Cement Creek were used to compute %AR for the reference and natural tracers. Values of %AR from natural tracers generally showed good agreement with values from the reference tracer, but variability in discharge and end-member concentrations and analytical errors contributed to unexpected outlier values for both injected and natural tracers. The median value (MV) %AR (calculated from all of the tracers) reduced scatter in the mixing plots for the dissolved metals, indicating that the MV estimate reduced the effects of various potential errors that could affect any tracer.

  13. Hydrodynamics of an electrochemical membrane bioreactor.

    PubMed

    Wang, Ya-Zhou; Wang, Yun-Kun; He, Chuan-Shu; Yang, Hou-Yun; Sheng, Guo-Ping; Shen, Jin-You; Mu, Yang; Yu, Han-Qing

    2015-05-22

    An electrochemical membrane bioreactor (EMBR) has recently been developed for energy recovery and wastewater treatment. The hydrodynamics of the EMBR would significantly affect the mass transfers and reaction kinetics, exerting a pronounced effect on reactor performance. However, only scarce information is available to date. In this study, the hydrodynamic characteristics of the EMBR were investigated through various approaches. Tracer tests were adopted to generate residence time distribution curves at various hydraulic residence times, and three hydraulic models were developed to simulate the results of tracer studies. In addition, the detailed flow patterns of the EMBR were acquired from a computational fluid dynamics (CFD) simulation. Compared to the tank-in-series and axial dispersion ones, the Martin model could describe hydraulic performance of the EBMR better. CFD simulation results clearly indicated the existence of a preferential or circuitous flow in the EMBR. Moreover, the possible locations of dead zones in the EMBR were visualized through the CFD simulation. Based on these results, the relationship between the reactor performance and the hydrodynamics of EMBR was further elucidated relative to the current generation. The results of this study would benefit the design, operation and optimization of the EMBR for simultaneous energy recovery and wastewater treatment.

  14. A physiology-based parametric imaging method for FDG-PET data

    NASA Astrophysics Data System (ADS)

    Scussolini, Mara; Garbarino, Sara; Sambuceti, Gianmario; Caviglia, Giacomo; Piana, Michele

    2017-12-01

    Parametric imaging is a compartmental approach that processes nuclear imaging data to estimate the spatial distribution of the kinetic parameters governing tracer flow. The present paper proposes a novel and efficient computational method for parametric imaging which is potentially applicable to several compartmental models of diverse complexity and which is effective in the determination of the parametric maps of all kinetic coefficients. We consider applications to [18 F]-fluorodeoxyglucose positron emission tomography (FDG-PET) data and analyze the two-compartment catenary model describing the standard FDG metabolization by an homogeneous tissue and the three-compartment non-catenary model representing the renal physiology. We show uniqueness theorems for both models. The proposed imaging method starts from the reconstructed FDG-PET images of tracer concentration and preliminarily applies image processing algorithms for noise reduction and image segmentation. The optimization procedure solves pixel-wise the non-linear inverse problem of determining the kinetic parameters from dynamic concentration data through a regularized Gauss-Newton iterative algorithm. The reliability of the method is validated against synthetic data, for the two-compartment system, and experimental real data of murine models, for the renal three-compartment system.

  15. Graphene Oxide Based Nanocarrier Combined with a pH-Sensitive Tracer: A Vehicle for Concurrent pH Sensing and pH-Responsive Oligonucleotide Delivery.

    PubMed

    Hsieh, Chia-Jung; Chen, Yu-Cheng; Hsieh, Pei-Ying; Liu, Shi-Rong; Wu, Shu-Pao; Hsieh, You-Zung; Hsu, Hsin-Yun

    2015-06-03

    We chemically tuned the oxidation status of graphene oxide (GO) and constructed a GO-based nanoplatform combined with a pH-sensitive fluorescence tracer that is designed for both pH sensing and pH-responsive drug delivery. A series of GOs oxidized to distinct degrees were examined to optimize the adsorption of the model drug, poly dT30. We determined that highly oxidized GO was a superior drug-carrier candidate in vitro when compared to GOs oxidized to lesser degrees. In the cell experiment, the synthesized pH-sensitive rhodamine dye was first applied to monitor cellular pH; under acidic conditions, protonated rhodamine fluoresces at 588 nm (λex=561 nm). When the dT30-GO nanocarrier was introduced into cells, a rhodamine-triggered competition reaction occurred, and this led to the release of the oligonucleotides and the quenching of rhodamine fluorescence by GO. Our results indicate high drug loading (FAM-dT30/GO=25/50 μg/mL) and rapid cellular uptake (<0.5 h) of the nanocarrier which can potentially be used for targeted RNAi delivery to the acidic milieu of tumors.

  16. Assessing Jet-Induced Spatial Mixing in a Rich, Reacting Crossflow

    NASA Technical Reports Server (NTRS)

    Demayo, T. N.; Leong, M. Y.; Samuelsen, G. S.

    2004-01-01

    In many advanced low NOx gas turbine combustion techniques, such as rich-burn/quick-mix/lean-burn (RQL), jet mixing in a reacting, hot, fuel-rich crossflow plays an important role in minimizing all pollutant emissions and maximizing combustion efficiency. Assessing the degree of mixing and predicting jet penetration is critical to the optimization of the jet injection design strategy. Different passive scalar quantities, including carbon, oxygen, and helium are compared to quantify mixing in an atmospheric RQL combustion rig under reacting conditions. The results show that the O2-based jet mixture fraction underpredicts the C-based mixture fraction due to jet dilution and combustion, whereas the He tracer overpredicts it possibly due to differences in density and diffusivity. The He-method also exhibits significant scatter in the mixture fraction data that can most likely be attributed to differences in gas density and turbulent diffusivity. The jet mixture fraction data were used to evaluate planar spatial unmixedness, which showed good agreement for all three scalars. This investigation suggests that, with further technique refinement, O2 or a He tracer could be used instead of C to determine the extent of reaction and mixing in an RQL combustor.

  17. Two-dimensional confocal laser scanning microscopy image correlation for nanoparticle flow velocimetry

    NASA Astrophysics Data System (ADS)

    Jun, Brian; Giarra, Matthew; Golz, Brian; Main, Russell; Vlachos, Pavlos

    2016-11-01

    We present a methodology to mitigate the major sources of error associated with two-dimensional confocal laser scanning microscopy (CLSM) images of nanoparticles flowing through a microfluidic channel. The correlation-based velocity measurements from CLSM images are subject to random error due to the Brownian motion of nanometer-sized tracer particles, and a bias error due to the formation of images by raster scanning. Here, we develop a novel ensemble phase correlation with dynamic optimal filter that maximizes the correlation strength, which diminishes the random error. In addition, we introduce an analytical model of CLSM measurement bias error correction due to two-dimensional image scanning of tracer particles. We tested our technique using both synthetic and experimental images of nanoparticles flowing through a microfluidic channel. We observed that our technique reduced the error by up to a factor of ten compared to ensemble standard cross correlation (SCC) for the images tested in the present work. Subsequently, we will assess our framework further, by interrogating nanoscale flow in the cell culture environment (transport within the lacunar-canalicular system) to demonstrate our ability to accurately resolve flow measurements in a biological system.

  18. Hydrodynamics of an Electrochemical Membrane Bioreactor

    PubMed Central

    Wang, Ya-Zhou; Wang, Yun-Kun; He, Chuan-Shu; Yang, Hou-Yun; Sheng, Guo-Ping; Shen, Jin-You; Mu, Yang; Yu, Han-Qing

    2015-01-01

    An electrochemical membrane bioreactor (EMBR) has recently been developed for energy recovery and wastewater treatment. The hydrodynamics of the EMBR would significantly affect the mass transfers and reaction kinetics, exerting a pronounced effect on reactor performance. However, only scarce information is available to date. In this study, the hydrodynamic characteristics of the EMBR were investigated through various approaches. Tracer tests were adopted to generate residence time distribution curves at various hydraulic residence times, and three hydraulic models were developed to simulate the results of tracer studies. In addition, the detailed flow patterns of the EMBR were acquired from a computational fluid dynamics (CFD) simulation. Compared to the tank-in-series and axial dispersion ones, the Martin model could describe hydraulic performance of the EBMR better. CFD simulation results clearly indicated the existence of a preferential or circuitous flow in the EMBR. Moreover, the possible locations of dead zones in the EMBR were visualized through the CFD simulation. Based on these results, the relationship between the reactor performance and the hydrodynamics of EMBR was further elucidated relative to the current generation. The results of this study would benefit the design, operation and optimization of the EMBR for simultaneous energy recovery and wastewater treatment. PMID:25997399

  19. Form and function in hillslope hydrology: in situ imaging and characterization of flow-relevant structures

    NASA Astrophysics Data System (ADS)

    Jackisch, Conrad; Angermann, Lisa; Allroggen, Niklas; Sprenger, Matthias; Blume, Theresa; Tronicke, Jens; Zehe, Erwin

    2017-07-01

    The study deals with the identification and characterization of rapid subsurface flow structures through pedo- and geo-physical measurements and irrigation experiments at the point, plot and hillslope scale. Our investigation of flow-relevant structures and hydrological responses refers to the general interplay of form and function, respectively. To obtain a holistic picture of the subsurface, a large set of different laboratory, exploratory and experimental methods was used at the different scales. For exploration these methods included drilled soil core profiles, in situ measurements of infiltration capacity and saturated hydraulic conductivity, and laboratory analyses of soil water retention and saturated hydraulic conductivity. The irrigation experiments at the plot scale were monitored through a combination of dye tracer, salt tracer, soil moisture dynamics, and 3-D time-lapse ground penetrating radar (GPR) methods. At the hillslope scale the subsurface was explored by a 3-D GPR survey. A natural storm event and an irrigation experiment were monitored by a dense network of soil moisture observations and a cascade of 2-D time-lapse GPR trenches. We show that the shift between activated and non-activated state of the flow paths is needed to distinguish structures from overall heterogeneity. Pedo-physical analyses of point-scale samples are the basis for sub-scale structure inference. At the plot and hillslope scale 3-D and 2-D time-lapse GPR applications are successfully employed as non-invasive means to image subsurface response patterns and to identify flow-relevant paths. Tracer recovery and soil water responses from irrigation experiments deliver a consistent estimate of response velocities. The combined observation of form and function under active conditions provides the means to localize and characterize the structures (this study) and the hydrological processes (companion study Angermann et al., 2017, this issue).

  20. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    PubMed

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

Top