Science.gov

Sample records for activity sampler 6-12

  1. Industrial Technology. Iowa Developed Energy Activity Sampler, 6-12. Revised.

    ERIC Educational Resources Information Center

    Iowa State Dept. of Education, Des Moines.

    The revised Iowa Developed Energy Activity Sampler (IDEAS) was compiled using the original IDEAS program and the Energy Conservation Activity Packets (ECAPS). This document is one of the series of revised IDEAS booklets, and provides activities for teaching industrial arts/technology education. The activities are intended to present energy…

  2. Industrial Technology. Iowa Developed Energy Activity Sampler, 6-12. Revised.

    ERIC Educational Resources Information Center

    Iowa State Dept. of Education, Des Moines. Div. of Instructional Services.

    The revised Iowa Developed Energy Activity Sampler (IDEAS) was compiled using the original IDEAS program and the Energy Conservation Activity Packets (ECAPS). This document is one of a series of revised IDEAS booklets, and provides learning activities for teachers to use with students in industrial arts/technology education. Each of the 17…

  3. Active Hydrazine Vapor Sampler (AHVS)

    NASA Technical Reports Server (NTRS)

    Young, Rebecca C.; Mcbrearty, Charles F.; Curran, Daniel J.

    1993-01-01

    The Active Hydrazine Vapor Sampler (AHVS) was developed to detect vapors of hydrazine (HZ) and monomethylhydrazine (MMH) in air at parts-per-billion (ppb) concentration levels. The sampler consists of a commercial personal pump that draws ambient air through paper tape treated with vanillin (4-hydroxy-3-methoxybenzaldehyde). The paper tape is sandwiched in a thin cardboard housing inserted in one of the two specially designed holders to facilitate sampling. Contaminated air reacts with vanillin to develop a yellow color. The density of the color is proportional to the concentration of HZ or MMH. The AHVS can detect 10 ppb in less than 5 minutes. The sampler is easy to use, low cost, and intrinsically safe and contains no toxic material. It is most beneficial for use in locations with no laboratory capabilities for instrumentation calibration. This paper reviews the development, laboratory test, and field test of the device.

  4. Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring.

    PubMed

    Geyh, A S; Roberts, P T; Lurmann, F W; Schoell, B M; Avol, E L

    1999-01-01

    Assessing personal exposure to ozone has only been feasible recently with the introduction of passive ozone samplers. These devices are easy to use, but changes in air velocity across their collection surfaces can affect performance. The Harvard active ozone sampler (AS) was developed in response to problems with the passive methods. This active sampler has been tested extensively as a microenvironmental sampler. To test for personal sampling, 40 children attending summer day-camp in Riverside, California wore the active ozone sampler for approximately 2.6 h on July 19 and 21, 1994, when ozone concentrations were about 100 ppb and 140 ppb, respectively. The children spent 94-100% of the sampling period outside, staying within a well-defined area while participating in normal camp activities. Ambient ozone concentrations across this area were monitored by two UV photometric ozone monitors. The active sampler was worn in a small backpack that was also equipped with a passive ozone sampler. Device precision, reported as the percent difference between duplicate pairs of samplers, was +/- 3.7% and +/- 4.2% for the active and passive samplers, respectively. The active sampler measured, on average, 94.5 +/- 8.2% of the ambient ozone while the passive samplers measured, on average, 124.5 +/- 18.8%. The samplers were worn successfully for the entire sampling period by all participating children. PMID:10321353

  5. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Mathematics.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Described is the Mathematics component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Also included in the program are activity sets for Home Economics (SE 034 678), Industrial Arts (SE 034 679), Language Arts (SE 034 680), Science (SE…

  6. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Industrial Arts.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Described is the Industrial Arts component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Also included in the program are activity sets for Home Economics (SE 034 678), Language Arts (SE 034 680), Mathematics (SE 034 681), Science (SE…

  7. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Science.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Presented is the Science component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Also contained in the program are activity sets for Home Economics (SE 034 678), Industrial Arts (SE 034 679), Language Arts (SE 034 680), Mathematics (SE…

  8. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Language Arts.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Presented is the Language Arts component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Among the lessons included are an energy debate, puzzles, energy poetry, and energy life styles. Also contained in the IDEAS program are activity sets…

  9. Sea Sampler: Aquatic Activities for the Field and Classroom. Elementary, Grades K-6.

    ERIC Educational Resources Information Center

    Allen, Wendy Beard, Ed.; McLaughlin, Patty Owens, Ed.

    The samplers of aquatic activities that are contained in this guide have been reviewed and trial tested for use with both elementary and secondary level students. The activities were a result of South Carolina Sea Grant's efforts to expand marine education opportunities in the state. The table of contents alphabetically lists the activities…

  10. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Introduction.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Presented is the Introduction for the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Included in the program are activity sets for Home Economics (SE 034 678), Industrial Arts (SE 034 679), Language Arts (SE 034 680), Mathematics (SE 034 681),…

  11. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Home Economics.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Presented is the Home Economics component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades 7-12. Also included in the program are activity sets for Industrial Arts (SE 034 679), Language Arts (SE 034 680), Mathematics (SE 034 681), Science (SE…

  12. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Social Studies.

    ERIC Educational Resources Information Center

    Simonis, Doris G.

    Described is the Social Studies component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades seven through twelve. Aspects of the energy situation addressed in these lessons include resource finiteness, exponential growth, standard of living,…

  13. Behaviordelia Sampler.

    ERIC Educational Resources Information Center

    Malott, Richard W., Ed.

    Behaviordelia Sampler is based on the same principle as a candy sampler or record sampler. It compiles excerpts from a variety of texts which Behaviordelia is now publishing. It is intended as a supplementary book of readings for courses in psychology and related fields and also as a catalog of their materials. Much of the sampler uses a comic…

  14. Dual effects of [Tyr(6)]-gamma2-MSH(6-12) on pain perception and in vivo hyperalgesic activity of its analogues.

    PubMed

    Wei, Chunnan; Huang, Wenmin; Xing, Xiaoting; Dong, Shouliang

    2010-09-01

    [Tyr(6)]-gamma2-MSH(6-12) with a short effecting time of about 20 min is one of the most potent rMrgC receptor agonists. To possibly increase its potency and metabolic stability, a series of analogues were prepared by replacing the Tyr(6) residue with the non-canonical amino acids 3-(1-naphtyl)-L-alanine, 4-fluoro-L-phenylalanine, 4-methoxy-L-phenylalanine and 3-nitro-L-tyrosine. Dose-dependent nociceptive assays performed in conscious rats by intrathecal injection of the MSH peptides showed [Tyr(6)]-gamma2-MSH(6-12) hyperalgesic effects at low doses (5-20 nmol) and analgesia at high doses (100-200 nmol). This analgesic activity is fully reversed by the kyotorphin receptor-specific antagonist Leu-Arg. For the two analogues containing in position 6, 4-fluoro-L-phenylalanine and 3-nitro-L-tyrosine, a hyperalgesic activity was not observed, while the 3-(1-naphtyl)-L-alanine analogue at 10 nmol dose was found to induce hyperalgesia at a potency very similar to gamma2-MSH(6-12), but with longer duration of the effect. Finally, the 4-methoxy-L-phenylalanine analogue (0.5 nmol) showed greatly improved hyperalgesic activity and prolonged effects compared to the parent [Tyr(6)]-gamma2-MSH(6-12) compound. PMID:20629198

  15. Honey Bees (Apis mellifera, L.) as Active Samplers of Airborne Particulate Matter

    PubMed Central

    Di Prisco, Gennaro; Caprio, Emilio; Pellecchia, Marco

    2015-01-01

    Honey bees (Apis mellifera L.) are bioindicators of environmental pollution levels. During their wide-ranging foraging activity, these hymenopterans are exposed to pollutants, thus becoming a useful tool to trace the environmental contaminants as heavy metals, pesticides, radionuclides and volatile organic compounds. In the present work we demonstrate that bees can also be used as active samplers of airborne particulate matter. Worker bees were collected from hives located in a polluted postmining area in South West Sardinia (Italy) that is also exposed to dust emissions from industrial plants. The area is included in an official list of sites of national interest for environmental remediation, and has been characterized for the effects of pollutants on the health of the resident population. The head, wings, hind legs and alimentary canal of the bees were investigated with Scanning Electron Microscopy coupled with X-ray spectroscopy (SEM-EDX). The analyses pointed to specific morphological and chemical features of the particulate, and resulted into the identification of three categories of particles: industry -, postmining -, and soil –derived. With the exception of the gut, all the analyzed body districts displayed inorganic particles, mostly concentrated in specific areas of the body (i.e. along the costal margin of the fore wings, the medial plane of the head, and the inner surface of the hind legs). The role of both past mining activities and the industrial activity close to the study area as sources of the particulate matter is also discussed. We conclude that honey bees are able to collect samples of the main airborne particles emitted from different sources, therefore could be an ideal tool for monitoring such a kind of pollutants. PMID:26147982

  16. Honey Bees (Apis mellifera, L.) as Active Samplers of Airborne Particulate Matter.

    PubMed

    Negri, Ilaria; Mavris, Christian; Di Prisco, Gennaro; Caprio, Emilio; Pellecchia, Marco

    2015-01-01

    Honey bees (Apis mellifera L.) are bioindicators of environmental pollution levels. During their wide-ranging foraging activity, these hymenopterans are exposed to pollutants, thus becoming a useful tool to trace the environmental contaminants as heavy metals, pesticides, radionuclides and volatile organic compounds. In the present work we demonstrate that bees can also be used as active samplers of airborne particulate matter. Worker bees were collected from hives located in a polluted postmining area in South West Sardinia (Italy) that is also exposed to dust emissions from industrial plants. The area is included in an official list of sites of national interest for environmental remediation, and has been characterized for the effects of pollutants on the health of the resident population. The head, wings, hind legs and alimentary canal of the bees were investigated with Scanning Electron Microscopy coupled with X-ray spectroscopy (SEM-EDX). The analyses pointed to specific morphological and chemical features of the particulate, and resulted into the identification of three categories of particles: industry-, postmining-, and soil-derived. With the exception of the gut, all the analyzed body districts displayed inorganic particles, mostly concentrated in specific areas of the body (i.e. along the costal margin of the fore wings, the medial plane of the head, and the inner surface of the hind legs). The role of both past mining activities and the industrial activity close to the study area as sources of the particulate matter is also discussed. We conclude that honey bees are able to collect samples of the main airborne particles emitted from different sources, therefore could be an ideal tool for monitoring such a kind of pollutants. PMID:26147982

  17. Novel active personal nanoparticle sampler for the exposure assessment of nanoparticles in workplaces.

    PubMed

    Tsai, Chuen-Jinn; Liu, Chun-Nan; Hung, Shao-Ming; Chen, Sheng-Chieh; Uang, Shi-Nian; Cheng, Yung-Sung; Zhou, Yue

    2012-04-17

    A novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (d(pa50)) of 4 μm and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 μm in the inner diameter) and a rotating, silicone oil-coated Teflon filter substrate at 1 rpm to achieve a uniform particle deposition and avoid solid particle bounce. A final filter is used after the impactor to collect the NPs. Calibration results show that the d(pa50) of the respirable cyclone and the micro-orifice impactor are 3.92 ± 0.22 μm and 101.4 ± 0.1 nm, respectively. The d(pa50) at the loaded micro-Al(2)O(3) mass of 0.36-3.18 mg is shifted to 102.9-101.2 nm, respectively, while it is shifted to 98.9-97.8 nm at the loaded nano-TiO(2) mass of 0.92-1.78 mg, respectively. That is, the shift of d(pa50) due to solid particle loading is small if the PENS is not overloaded. Both NPs and RPM concentrations were found to agree well with those of the IOSH respirable cyclone and MOUDI. By using the present PENS, the collected samples can be further analyzed for chemical species concentrations besides gravimetric analysis to determine the actual exposure concentrations of ENMs in both RPM and NPs fractions in workplaces, which are often influenced by the background or incident pollution sources. PMID:22435654

  18. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    USGS Publications Warehouse

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  19. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    PubMed

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. PMID:24419241

  20. Use of depuration compounds in passive air samplers: results from active sampling-supported field deployment, potential uses, and recommendations.

    PubMed

    Moeckel, Claudia; Harner, Tom; Nizzetto, Luca; Strandberg, Bo; Lindroth, Anders; Jones, Kevin C

    2009-05-01

    Depuration compounds (DCs) are added to passive air samplers (PAS) prior to deployment to account for the wind-dependency of the sampling rate for gas-phase compounds. This correction is particularly useful for providing comparable data for samplers that are deployed in different environments and subject to different meteorological conditions such as wind speeds. Two types of PAS--the polyurethane foam (PUF) disk sampler and semipermeable membrane devices (SPMDs)--were deployed at eight heights on a 100 m tower to test whether the DC approach could yield air concentrations profiles for PCBs and organochlorine pesticides and account for the wind speed gradient with height. Average wind speeds ranged from 0.3 to 4.5 m s(-1) over the 40 day deployment, increasing with height Two low volume active air samples (AAS), one collected at 25 m and one at 73 m over the 40 day deployment showed no significant concentration differences for target compounds. As expected, the target compounds taken up by PAS reflected the wind profile with height This wind-dependency of the PAS was also reflected in the results of the DCs. A correction based on the DC approach successfully accounted for the effect of wind on PAS sampling rates, yielding a profile consistent with the AAS. Interestingly, in terms of absolute air concentrations, there were differences between the AAS and PAS-derived values for some target compounds. These were attributed to different sampling characteristics of the two approaches that may have resulted in slightly different air masses being sampled. Based on the results of this study, guidelines are presented for the use of DCs and for the calibration of PAS using AAS. PMID:19534139

  1. Sludge sampler

    DOEpatents

    Ward, R.C.

    1981-06-25

    The disclosure relates to a sludge sampler comprising an elongated generally cylindrical housing containing a baffle containing an aperture. Connected to the aperture is a flexible tubing having a valve for maintaining and releasing pressure in the lower end of the housing and exiting the upper end of the housing. The lower end of the housing contains a ball check valve maintained in closed position by pressure. When the lower end of the device contacts the sludge bed, the pressure valve is opened, enabling sludge to enter the lower end of the housing. After the sample is collected the valve is closed. An upsetting pin opens the valve to empty a sludge sample after the sample is removed from the fluid.

  2. Sludge sampler

    DOEpatents

    Ward, Ralph C.

    1983-01-01

    The disclosure relates to a sludge sampler comprising an elongated generally cylindrical housing containing a baffle containing an aperture. Connected to the aperture is a flexible tubing having a valve for maintaining and releasing pressure in the lower end of the housing and exiting the upper end of the housing. The lower end of the housing contains a ball check valve maintained in closed position by pressure. When the lower end of the device contacts the sludge bed, the pressure valve is opened, enabling sludge to enter the lower end of the housing. After the sample is collected the valve is closed. An upsetting pin opens the valve to empty a sludge sample after the sample is removed from the fluid.

  3. Polyoxymethylene passive samplers to monitor changes in bioavailability and flux of PCBs after activated carbon amendment to sediment in the field.

    PubMed

    Beckingham, B; Ghosh, U

    2013-06-01

    Field and laboratory exposures of polyoxymethylene passive samplers to sediments and the water column were applied to monitor changes in bioavailability and flux of polychlorinated biphenyls (PCBs) following a pilot-scale amendment of activated carbon in Grasse River. Following amendment, reductions in passive sampler uptake tracked reductions in bioaccumulation in a freshwater invertebrate, which supports a biological basis for utilizing passive samplers for in situ site investigations following a remediation. Freely dissolved concentrations of PCBs were reduced in sediment pore waters compared to untreated sediments indicating reduced bioavailability of PCBs after activated carbon amendment. Freely dissolved PCB concentrations in sediment pore water in treated sites were also lower than overlying water concentrations indicating a reversal of the sediment from being a source to a sink of PCBs from the water column. These observations indicate that activated carbon amendment to sediment limits contaminant exposure to both the benthic and pelagic food webs through reductions in bioavailability and flux of PCBs into the water column. PMID:23415491

  4. DEVELOPMENT OF AN ACTIVE PERSONAL OZONE SAMPLER USING A HOLLOW TUBE DIFFUSION DENUDER

    EPA Science Inventory

    Personal, microenvironmental and indoor ozone monitoring is currently conducted using a lightweight, inexpensive sampling device. lthough the passive device is adequate for many studies, we are developing a relatively ight weight active hollow tube diffusion denuder system which ...

  5. Environmental Curiosity Sampler.

    ERIC Educational Resources Information Center

    Stehney, Virginia A.

    The Sampler is designed to stimulate teachers, parents, students, and groups to look at various types of open spaces and facilities as resources for environmental study. Written for use with children, but adaptable to older groups, the Sampler tries to engage the feelings as well as intellects of its users in the process of inquiry. It locates…

  6. A Stress Control Workbook for Youth Grades 6-12.

    ERIC Educational Resources Information Center

    Trotter, Jennie C.

    Stress is an inevitable part of students' lives, but too much stress can have damaging consequences. Ways in which children can respond positively are covered in this stress booklet. Intended for students in grades 6-12, the booklet is divided into 20 lessons on stress. Each lesson features various activities, role plays, exercises, and checklists…

  7. The Gibbs Centroid Sampler

    SciTech Connect

    Thompson, William A.; Newberg, Lee A.; Conlan, Sean; McCue, Lee Ann; Lawrence, Charles E.

    2007-07-01

    The Gibbs Centroid Sampler is a software package designed for locating conserved elements in biopolymer sequences. The Gibbs Centroid Sampler reports a centroid alignment, i.e., an alignment that has the minimum total distance to the set of samples chosen from the a posteriori probability distribution of transcription factor binding site alignments. In so doing, it garners information from the full ensemble of solutions, rather than only the single most probable point that is the target of many motif finding algorithms, including its predecessor, the Gibbs Recursive Sampler. Centroid estimators have been shown to yield substantial improvements, in both sensitivity and positive predictive values, to the prediction of RNA secondary structure and motif finding. The Gibbs Centroid Sampler, along with interactive tutorials, an online user manual, and information on downloading the software, is available at http://bayesweb.wadsworth.org/gibbs/gibbs.html.

  8. Variable percentage sampler

    DOEpatents

    Miller, Jr., William H.

    1976-01-01

    A remotely operable sampler is provided for obtaining variable percentage samples of nuclear fuel particles and the like for analyses. The sampler has a rotating cup for a sample collection chamber designed so that the effective size of the sample inlet opening to the cup varies with rotational speed. Samples of a desired size are withdrawn from a flowing stream of particles without a deterrent to the flow of remaining particles.

  9. Isokinetic air sampler

    DOEpatents

    Sehmel, George A.

    1979-01-01

    An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

  10. Breathing zone air sampler

    DOEpatents

    Tobin, John

    1989-01-01

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  11. Environmental Awareness Sampler.

    ERIC Educational Resources Information Center

    Halnen, Andrew; And Others

    This sampler for teachers provides information for initiating and dealing with environmental studies in the classroom. Utilizing an interdisciplinary approach, behavioral objectives related to environmental awareness are listed for social studies, science, mathematics, language arts, health, physical education, recreation, music, and local…

  12. Variable depth core sampler

    DOEpatents

    Bourgeois, Peter M.; Reger, Robert J.

    1996-01-01

    A variable depth core sampler apparatus comprising a first circular hole saw member, having longitudinal sections that collapses to form a point and capture a sample, and a second circular hole saw member residing inside said first hole saw member to support the longitudinal sections of said first hole saw member and prevent them from collapsing to form a point. The second hole saw member may be raised and lowered inside said first hole saw member.

  13. Variable depth core sampler

    DOEpatents

    Bourgeois, P.M.; Reger, R.J.

    1996-02-20

    A variable depth core sampler apparatus is described comprising a first circular hole saw member, having longitudinal sections that collapses to form a point and capture a sample, and a second circular hole saw member residing inside said first hole saw member to support the longitudinal sections of said first hole saw member and prevent them from collapsing to form a point. The second hole saw member may be raised and lowered inside said first hole saw member. 7 figs.

  14. High speed transient sampler

    DOEpatents

    McEwan, Thomas E.

    1995-01-01

    A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing.

  15. High speed transient sampler

    DOEpatents

    McEwan, T.E.

    1995-11-28

    A high speed sampler comprises a meandered sample transmission line for transmitting an input signal, a straight strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates along the transmission lines. The sampling gates comprise a four terminal diode bridge having a first strobe resistor connected from a first terminal of the bridge to the positive strobe line, a second strobe resistor coupled from the third terminal of the bridge to the negative strobe line, a tap connected to the second terminal of the bridge and to the sample transmission line, and a sample holding capacitor connected to the fourth terminal of the bridge. The resistance of the first and second strobe resistors is much higher than the signal transmission line impedance in the preferred system. This results in a sampling gate which applies a very small load on the sample transmission line and on the strobe generator. The sample holding capacitor is implemented using a smaller capacitor and a larger capacitor isolated from the smaller capacitor by resistance. The high speed sampler of the present invention is also characterized by other optimizations, including transmission line tap compensation, stepped impedance strobe line, a multi-layer physical layout, and unique strobe generator design. A plurality of banks of such samplers are controlled for concatenated or interleaved sample intervals to achieve long sample lengths or short sample spacing. 17 figs.

  16. 46 CFR 12.01-6-12.01-7 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false 12.01-6-12.01-7 Section 12.01-6-12.01-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MERCHANT MARINE OFFICERS AND SEAMEN REQUIREMENTS FOR RATING ENDORSEMENTS General §§ 12.01-6-12.01-7...

  17. 36 CFR 6.12 - Prohibited acts and penalties.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Prohibited acts and penalties. 6.12 Section 6.12 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR SOLID WASTE DISPOSAL SITES IN UNITS OF THE NATIONAL PARK SYSTEM § 6.12 Prohibited acts and penalties. (a) The following are prohibited:...

  18. Vacuum probe surface sampler

    NASA Technical Reports Server (NTRS)

    Zahlava, B. A. (Inventor)

    1973-01-01

    A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

  19. Polyport atmospheric gas sampler

    DOEpatents

    Guggenheim, S. Frederic

    1995-01-01

    An atmospheric gas sampler with a multi-port valve which allows for multi, sequential sampling of air through a plurality of gas sampling tubes mounted in corresponding gas inlet ports. The gas sampler comprises a flow-through housing which defines a sampling chamber and includes a gas outlet port to accommodate a flow of gases through the housing. An apertured sample support plate defining the inlet ports extends across and encloses the sampling chamber and supports gas sampling tubes which depend into the sampling chamber and are secured across each of the inlet ports of the sample support plate in a flow-through relation to the flow of gases through the housing during sampling operations. A normally closed stopper means mounted on the sample support plate and operatively associated with each of the inlet ports blocks the flow of gases through the respective gas sampling tubes. A camming mechanism mounted on the sample support plate is adapted to rotate under and selectively lift open the stopper spring to accommodate a predetermined flow of gas through the respective gas sampling tubes when air is drawn from the housing through the outlet port.

  20. Preparation and Characterization of the Activated Carbon-Nylon Beads: Novel Material for In Situ Microbe Sampler and Microcosm Experiment in Groundwater Environment

    NASA Astrophysics Data System (ADS)

    Liu, J.; Liu, H.

    2015-12-01

    The organic pollution of groundwater is a widespread problem in the word. It is significant to study the microbial community especially related to organic contaminant biodegradation and their variation with groundwater environment parameters, so as to evaluate the biodegradability of the organic contaminants and then make a right decision for bioremediation. One of good ways for this study is to build a microcosm in groundwater containing target contaminant, where microbes especially relating to biodegradation will grow in the microcosm and be collected for analysis. This research aims to prepare a novel material for in situ microbe sampler and microcosm experiment in groundwater environment. The novel material, namely, the activated carbon-nylon (AC-N) beads, was prepared using activated carbon and nylon as main raw materials. The material consists of 3-4mm diameter spherical beads (Fig.1A and Fig.2 A) which have an internal surface area greater than 500 m2 g-1. FT-IR spectra (Fig.3) indicated the composition of activated carbon and nylon due to the variation of the peaks at the near 1627 cm-1and 1558 -1538 cm-1 before and after complex reaction. The equilibrium adsorption capacity of benzene on the beads was 16.76 mg/g at the initial concentration of 100 mg/L. The adsorption kinetics was found to follow the pseudo-second-order kinetic model (Fig.4). The mechanism of the adsorption process was determined from the intraparticle diffusion model. Camera and SEM images (Fig.1 B and Fig.2 A and B) showed that the beads had an open and channel pore structures, the microbes might enter into and grow up in the beads (Fig.1 C and Fig.2 C). All these results showed that the AC-N beads could form the in situ microcosm of organic pollutants and microbes, which provided a promising prospect for assessing the biodegradability of the organic pollutants by intrinsic microbes in the groundwater.

  1. Multispectral Resource Sampler Workshop

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The utility of the multispectral resource sampler (MRS) was examined by users in the following disciplines: agriculture, atmospheric studies, engineering, forestry, geology, hydrology/oceanography, land use, and rangelands/soils. Modifications to the sensor design were recommended and the desired types of products and number of scenes required per month were indicated. The history, design, capabilities, and limitations of the MRS are discussed as well as the multilinear spectral array technology which it uses. Designed for small area inventory, the MRS can provide increased temporal, spectral, and spatial resolution, facilitate polarization measurement and atmospheric correction, and test onboard data compression techniques. The advantages of using it along with the thematic mapper are considered.

  2. Differential atmospheric tritium sampler

    DOEpatents

    Griesbach, Otto A.; Stencel, Joseph R.

    1990-01-01

    An atmospheric tritium sampler is provided which uses a carrier gas comprised of hydrogen gas and a diluting gas, mixed in a nonexplosive concentration. Sample air and carrier gas are drawn into and mixed in a manifold. A regulator meters the carrier gas flow to the manifold. The air sample/carrier gas mixture is pulled through a first moisture trap which adsorbs water from the air sample. The mixture then passes through a combustion chamber where hydrogen gas in the form of H.sub.2 or HT is combusted into water. The manufactured water is transported by the air stream to a second moisture trap where it is adsorbed. The air is then discharged back into the atmosphere by means of a pump.

  3. Parallel optical sampler

    SciTech Connect

    Tauke-Pedretti, Anna; Skogen, Erik J; Vawter, Gregory A

    2014-05-20

    An optical sampler includes a first and second 1.times.n optical beam splitters splitting an input optical sampling signal and an optical analog input signal into n parallel channels, respectively, a plurality of optical delay elements providing n parallel delayed input optical sampling signals, n photodiodes converting the n parallel optical analog input signals into n respective electrical output signals, and n optical modulators modulating the input optical sampling signal or the optical analog input signal by the respective electrical output signals, and providing n successive optical samples of the optical analog input signal. A plurality of output photodiodes and eADCs convert the n successive optical samples to n successive digital samples. The optical modulator may be a photodiode interconnected Mach-Zehnder Modulator. A method of sampling the optical analog input signal is disclosed.

  4. Laser pulse sampler

    DOEpatents

    Vann, Charles

    1998-01-01

    The Laser Pulse Sampler (LPS) measures temporal pulse shape without the problems of a streak camera. Unlike the streak camera, the laser pulse directly illuminates a camera in the LPS, i.e., no additional equipment or energy conversions are required. The LPS has several advantages over streak cameras. The dynamic range of the LPS is limited only by the range of its camera, which for a cooled camera can be as high as 16 bits, i.e., 65,536. The LPS costs less because there are fewer components, and those components can be mass produced. The LPS is easier to calibrate and maintain because there is only one energy conversion, i.e., photons to electrons, in the camera.

  5. Laser pulse sampler

    DOEpatents

    Vann, C.

    1998-03-24

    The Laser Pulse Sampler (LPS) measures temporal pulse shape without the problems of a streak camera. Unlike the streak camera, the laser pulse directly illuminates a camera in the LPS, i.e., no additional equipment or energy conversions are required. The LPS has several advantages over streak cameras. The dynamic range of the LPS is limited only by the range of its camera, which for a cooled camera can be as high as 16 bits, i.e., 65,536. The LPS costs less because there are fewer components, and those components can be mass produced. The LPS is easier to calibrate and maintain because there is only one energy conversion, i.e., photons to electrons, in the camera. 5 figs.

  6. Waveform Sampler CAMAC Module

    SciTech Connect

    Freytag, D.R.; Haller, G.M.; Kang, H.; Wang, J.

    1985-09-01

    A Waveform Sampler Module (WSM) for the measurement of signal shapes coming from the multi-hit drift chambers of the SLAC SLC detector is described. The module uses a high speed, high resolution analog storage device (AMU) developed in collaboration between SLAC and Stanford University. The AMU devices together with high speed TTL clocking circuitry are packaged in a hybrid which is also suitable for mounting on the detector. The module is in CAMAC format and provides eight signal channels, each recording signal amplitude versus time in 512 cells at a sampling rate of up to 360 MHz. Data are digitized by a 12-bit ADC with a 1 ..mu..s conversion time and stored in an on-board memory accessible through CAMAC.

  7. Differential atmospheric tritium sampler

    DOEpatents

    Griesbach, O.A.; Stencel, J.R.

    1987-10-02

    An atmospheric tritium sampler is provided which uses a carrier gas comprised of hydrogen gas and a diluting gas, mixed in a nonexplosive concentration. Sample air and carrier gas are drawn into and mixed in a manifold. A regulator meters the carrier gas flow to the manifold. The air sample/carrier gas mixture is pulled through a first moisture trap which adsorbs water from the air sample. The moisture then passes through a combustion chamber where hydrogen gas in the form of H/sub 2/ or HT is combusted into water. The manufactured water is transported by the air stream to a second moisture trap where it is adsorbed. The air is then discharged back into the atmosphere by means of a pump.

  8. Active Sampling Device for Determining Pollutants in Surface and Pore Water - the In Situ Sampler for Biphasic Water Monitoring.

    PubMed

    Supowit, Samuel D; Roll, Isaac B; Dang, Viet D; Kroll, Kevin J; Denslow, Nancy D; Halden, Rolf U

    2016-01-01

    We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040-0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction. PMID:26905924

  9. Active Sampling Device for Determining Pollutants in Surface and Pore Water - the In Situ Sampler for Biphasic Water Monitoring

    NASA Astrophysics Data System (ADS)

    Supowit, Samuel D.; Roll, Isaac B.; Dang, Viet D.; Kroll, Kevin J.; Denslow, Nancy D.; Halden, Rolf U.

    2016-02-01

    We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040-0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction.

  10. Active Sampling Device for Determining Pollutants in Surface and Pore Water – the In Situ Sampler for Biphasic Water Monitoring

    PubMed Central

    Supowit, Samuel D.; Roll, Isaac B.; Dang, Viet D.; Kroll, Kevin J.; Denslow, Nancy D.; Halden, Rolf U.

    2016-01-01

    We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040–0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction. PMID:26905924

  11. Retained gas sampler interface volume

    SciTech Connect

    Cannon, N.S.

    1997-10-01

    The maximum Retained Gas Sampler (RGS) interface volume was determined; this volume can trap contamination gases during the sampling process. A new technique (helium backfill) for eliminating contamination gases from the RGS sampler interface volume is described, and verification testing reported. Also demonstrated was that RGS data obtained prior to the introduction of the new helium backfill technique can be compensated for air contamination using the measured oxygen concentration and normal air composition.

  12. High speed sampler and demultiplexer

    DOEpatents

    McEwan, Thomas E.

    1995-01-01

    A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as "strobe kickout". The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition.

  13. High speed sampler and demultiplexer

    DOEpatents

    McEwan, T.E.

    1995-12-26

    A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as ``strobe kickout``. The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition. 16 figs.

  14. Automated particulate sampler field test model operations guide

    SciTech Connect

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  15. Evaluation criteria for bioaerosol samplers.

    PubMed

    Kesavan, Jana; Sagripanti, Jose-Luis

    2015-03-01

    Humans contract a variety of serious diseases through inhalation of infectious aerosols. Thus, the importance of monitoring air for microbial, toxic, or allergic content is recognized in clinical, occupational, and biodefense arenas. However, accurate monitoring of potentially contaminated environments can be hampered by selection of aerosol samplers with inadequate performance for the intended task. In this study, 29 aerosol samplers were evaluated based on their respective air flow, size, weight, power consumption, and efficiency in sampling particles in the respirable range. The resulting data demonstrates that sampling air flow and efficiency vary widely, and cannot be predicted from the physical characteristics of air samplers, and hence, that proper selection of air samplers should be more involved than shopping for a device based on the limited characteristics that are published by the manufacturers. The findings are summarized in an approach to rationally select bioaerosol samplers for use in infection control and environmental biomonitoring. The presented data demonstrates that inadequate selection of air samplers could result in a failure to collect particles of interest and thus, underestimate the risk and provide a false sense of security in contaminated health care settings and environments contaminated with infectious or toxic aerosols. PMID:25631321

  16. Variable depth core sampler

    SciTech Connect

    Bourgeois, P.M.; Reger, R.J.

    1994-12-31

    This invention relates to a sampling means, more particularly to a device to sample hard surfaces at varying depths. Often it is desirable to take samples of a hard surface wherein the samples are of the same diameter but of varying depths. Current practice requires that a full top-to-bottom sample of the material be taken, using a hole saw, and boring a hole from one end of the material to the other. The sample thus taken is removed from the hole saw and the middle of said sample is then subjected to further investigation. This paper describes a variable depth core sampler comprimising a circular hole saw member, having longitudinal sections that collapse to form a point and capture a sample, and a second saw member residing inside the first hole saw member to support the longitudinal sections of the first member and prevent them from collapsing to form a point. The second hole saw member may be raised and lowered inside the the first hole saw member.

  17. Pesticide monitoring in surface water and groundwater using passive samplers

    NASA Astrophysics Data System (ADS)

    Kodes, V.; Grabic, R.

    2009-04-01

    Passive samplers as screening devices have been used within a czech national water quality monitoring network since 2002 (SPMD and DGT samplers for non polar substances and metals). The passive sampler monitoring of surface water was extended to polar substances, in 2005. Pesticide and pharmaceutical POCIS samplers have been exposed in surface water at 21 locations and analysed for polar pesticides, perfluorinated compounds, personal care products and pharmaceuticals. Pesticide POCIS samplers in groundwater were exposed at 5 locations and analysed for polar pesticides. The following active substances of plant protection products were analyzed in surface water and groundwater using LC/MS/MS: 2,4,5-T, 2,4-D, Acetochlor, Alachlor, Atrazine, Atrazine_desethyl, Azoxystrobin, Bentazone, Bromacil, Bromoxynil, Carbofuran, Clopyralid, Cyanazin, Desmetryn, Diazinon, Dicamba, Dichlobenil, Dichlorprop, Dimethoat, Diuron, Ethofumesate, Fenarimol, Fenhexamid, Fipronil, Fluazifop-p-butyl, Hexazinone, Chlorbromuron, Chlorotoluron, Imazethapyr, Isoproturon, Kresoxim-methyl, Linuron, MCPA, MCPP, Metalaxyl, Metamitron, Methabenzthiazuron, Methamidophos, Methidathion, Metobromuron, Metolachlor, Metoxuron, Metribuzin, Monolinuron, Nicosulfuron, Phorate, Phosalone, Phosphamidon, Prometryn, Propiconazole, Propyzamide, Pyridate, Rimsulfuron, Simazine, Tebuconazole, Terbuthylazine, Terbutryn, Thifensulfuron-methyl, Thiophanate-methyl and Tri-allate. The POCIS samplers performed very well being able to provide better picture than grab samples. The results show that polar pesticides and also perfluorinated compounds, personal care products and pharmaceuticals as well occur in hydrosphere of the Czech republic. Acknowledgment: Authors acknowledge the financial support of grant No. 2B06095 by the Ministry of Education, Youth and Sports.

  18. A High Volume Stack Sampler

    NASA Technical Reports Server (NTRS)

    Boubel, Richard W.

    1971-01-01

    The stack sampler described in this paper has been developed to overcome the difficulties of particulate sampling with presently available equipment. Its use on emissions from hog fuel fired boilers, back-fired incinerators, wigwam burners, asphalt plants, and seed cleaning cyclones is reported. The results indicate that the sampler is rapid and reliable in its use. It is relatively simple and inexpensive to operate. For most sources it should be considered over the more complicated and expensive sampling trains being used and specified.

  19. Teaching Global Awareness Using the Media. Grades 6-12, Global Awareness Series.

    ERIC Educational Resources Information Center

    Lamy, Steven L.; And Others

    This teaching guide on global awareness contains 15 media-related activities for students in grades 6-12. The objective is to help students see how the media affect their opinions and the roles the media plays in world affairs. The activities are divided into five sections. The first section contains a general survey of the students' knowledge of…

  20. An operation manual for a time-series, storm-activated suspended sediment sampler deployed in the coastal ocean: function, maintenance, and testing procedures

    USGS Publications Warehouse

    Rendigs, Richard R.; Bothner, Michael H.

    2004-01-01

    This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.

  1. A modified siphon sampler for shallow water

    USGS Publications Warehouse

    Diehl, Timothy H.

    2008-01-01

    A modified siphon sampler (or 'single-stage sampler') was developed to sample shallow water at closely spaced vertical intervals. The modified design uses horizontal rather than vertical sample bottles. Previous siphon samplers are limited to water about 20 centimeters (cm) or more in depth; the modified design can sample water 10 cm deep. Several mounting options were used to deploy the modified siphon sampler in shallow bedrock streams of Middle Tennessee, while minimizing alteration of the stream bed. Sampling characteristics and limitations of the modified design are similar to those of the original design. Testing showed that the modified sampler collects unbiased samples of suspended silt and clay. Similarity of the intake to the original siphon sampler suggests that the modified sampler would probably take downward-biased samples of suspended sand. Like other siphon samplers, it does not sample isokinetically, and the efficiency of sand sampling can be expected to change with flow velocity. The sampler needs to be located in the main flow of the stream, and is subject to damage from rapid flow and floating debris. Water traps were added to the air vents to detect the flow of water through the sampler, which can cause a strong upward bias in sampled suspended-sediment concentration. Water did flow through the sampler, in some cases even when the top of the air vent remained above water. Air vents need to be extended well above maximum water level to prevent flow through the sampler.

  2. VALIDATION OF SAMPLERS FOR INHALED PARTICULATE MATTER

    EPA Science Inventory

    Methods for the testing of new samplers for inhalable particles have been developed and applied to the dichotomous sampler and the size-selective hi-vol. The sampling effectiveness of the inlet to the dichotomous sampler was measured and found to be excessively dependent on wind ...

  3. A PERSONAL PARTICLE SPECIATION SAMPLER

    EPA Science Inventory

    Dr. Susanne Hering of Aerosol Dynamics Inc and her colleagues expect to design and validate a personal monitoring sampler for particles smaller than 2.5 µm (PM2.5) that is suitable for subsequent chemical speciation work. The investigators believe the result will be a...

  4. A Sampler of Ethnic Crafts.

    ERIC Educational Resources Information Center

    Donley, Susan K.; And Others

    This curriculum guide provides a sampler of the wide variety of expression practiced by cultural groups all over the world. The guide was developed to help fill the need for multicultural art resources that are respectful of both modern art education philosophy and of authentic, sensitive representation of other cultures. The types of materials…

  5. Using a Checking Account. Grades 6-12.

    ERIC Educational Resources Information Center

    Trey, Frances

    Instructions and exercises on the use of checking accounts are provided for students in grades 6-12. The following topics are included: (1) reasons for opening a checking account; (2) how to open a checking account; (3) how to fill out deposit slips; (4) the elements of a check and how to write a check correctly; (5) checking account rules; (6)…

  6. Parallel Curriculum Units for Science, Grades 6-12

    ERIC Educational Resources Information Center

    Leppien, Jann H.; Purcell, Jeanne H.

    2011-01-01

    Based on the best-selling book "The Parallel Curriculum", this professional development resource gives multifaceted examples of rigorous learning opportunities for science students in Grades 6-12. The four sample units revolve around genetics, the convergence of science and society, the integration of language arts and biology, and the periodic…

  7. 36 CFR 6.12 - Prohibited acts and penalties.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (4) Operating a solid waste disposal site in violation of 40 CFR Parts 257 or 258, or in violation of... INTERIOR SOLID WASTE DISPOSAL SITES IN UNITS OF THE NATIONAL PARK SYSTEM § 6.12 Prohibited acts and penalties. (a) The following are prohibited: (1) Operating a solid waste disposal site without a...

  8. Ultra-wideband directional sampler

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    The Ultra-Wideband (UWB) Directional Sampler is a four port device that combines the function of a directional coupler with a high speed sampler. Two of the four ports operate at a high sub-nanosecond speed, in "real time", and the other two ports operate at a slow millisecond-speed, in "equivalent time". A signal flowing inbound to either of the high speed ports is sampled and coupled, in equivalent time, to the adjacent equivalent time port while being isolated from the opposite equivalent time port. A primary application is for a time domain reflectometry (TDR) situation where the reflected pulse returns while the outbound pulse is still being transmitted, such as when the reflecting discontinuity is very close to the TDR apparatus.

  9. Ultra-wideband directional sampler

    DOEpatents

    McEwan, T.E.

    1996-05-14

    The Ultra-Wideband (UWB) Directional Sampler is a four port device that combines the function of a directional coupler with a high speed sampler. Two of the four ports operate at a high sub-nanosecond speed, in ``real time``, and the other two ports operate at a slow millisecond-speed, in ``equivalent time``. A signal flowing inbound to either of the high speed ports is sampled and coupled, in equivalent time, to the adjacent equivalent time port while being isolated from the opposite equivalent time port. A primary application is for a time domain reflectometry (TDR) situation where the reflected pulse returns while the outbound pulse is still being transmitted, such as when the reflecting discontinuity is very close to the TDR apparatus. 3 figs.

  10. Development and field validation of a new diffusive sampler for determination of atmospheric volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Özden Üzmez, Özlem; Gaga, Eftade O.; Döğeroğlu, Tuncay

    2015-04-01

    A tailor-made diffusive sampler was developed for the determination of atmospheric Volatile Organic Compounds (VOCs) and the validation of the sampler was carried out under field conditions. All parts of the diffusive sampler which are reusable after a proper cleaning process were made of plastic material (delrin). The reusability of the sampler brings an important advantage considering its lower cost. Activated carbon was used as adsorbent and VOCs adsorbed on the activated carbon were analyzed by GC-MS (gas chromatography equipped with mass selective detector). A comprehensive validation study including detection limit, precision, bias, recovery, self-consistency, shelf life, storage stability, reusability was carried out in accordance with the related European standards ((EN) 13528-1 (2000) and 13528-2 (2000)). Also, a comparison was performed with some commercial diffusive samplers such as 3 M OVM 3500 and Radiello to test the performance of the new diffusive sampler in different environments such as urban area and road tunnel. Uptake rates for the measured VOCs were determined and they were evaluated together with the meteorological parameters (temperature, humidity, wind speed). According to the validation results; all the parameters evaluated for the sampler comply with the related standards and this is an indication of the reliability of the sampler for the sampling of VOCs in the atmosphere.

  11. Releasable Asbestos Field Sampler

    EPA Science Inventory

    Asbestos aerosolization (or releasability) is the potential for fibrous asbestos structures that are present in a material or on a solid surface to become airborne when the source is disturbed by human activities or natural forces. In turn, the magnitude of the airborne concentra...

  12. Silicone wristbands as personal passive samplers.

    PubMed

    O'Connell, Steven G; Kincl, Laurel D; Anderson, Kim A

    2014-03-18

    Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual's exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposure with silicone wristbands as personal passive samplers. Laboratory methodology affecting precleaning, infusion, and extraction were developed from commercially available silicone, and chromatographic background interference was reduced after solvent cleanup with good extraction efficiency (>96%). After finalizing laboratory methods, 49 compounds were sequestered during an ambient deployment which encompassed a diverse set of compounds including polycyclic aromatic hydrocarbons (PAHs), consumer products, personal care products, pesticides, phthalates, and other industrial compounds ranging in log K(ow) from -0.07 (caffeine) to 9.49 (tris(2-ethylhexyl) phosphate). In two hot asphalt occupational settings, silicone personal samplers sequestered 25 PAHs during 8- and 40-h exposures, as well as 2 oxygenated-PAHs (benzofluorenone and fluorenone) suggesting temporal sensitivity over a single work day or week (p < 0.05, power =0.85). Additionally, the amount of PAH sequestered differed between worksites (p < 0.05, power = 0.99), suggesting spatial sensitivity using this novel application. PMID:24548134

  13. Silicone Wristbands as Personal Passive Samplers

    PubMed Central

    2014-01-01

    Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual’s exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposure with silicone wristbands as personal passive samplers. Laboratory methodology affecting precleaning, infusion, and extraction were developed from commercially available silicone, and chromatographic background interference was reduced after solvent cleanup with good extraction efficiency (>96%). After finalizing laboratory methods, 49 compounds were sequestered during an ambient deployment which encompassed a diverse set of compounds including polycyclic aromatic hydrocarbons (PAHs), consumer products, personal care products, pesticides, phthalates, and other industrial compounds ranging in log Kow from −0.07 (caffeine) to 9.49 (tris(2-ethylhexyl) phosphate). In two hot asphalt occupational settings, silicone personal samplers sequestered 25 PAHs during 8- and 40-h exposures, as well as 2 oxygenated-PAHs (benzofluorenone and fluorenone) suggesting temporal sensitivity over a single work day or week (p < 0.05, power =0.85). Additionally, the amount of PAH sequestered differed between worksites (p < 0.05, power = 0.99), suggesting spatial sensitivity using this novel application. PMID:24548134

  14. Hydrazine-Vapor Samplers

    NASA Technical Reports Server (NTRS)

    Young, Rebecca; Mcbrearty, Charles; Curran, Dan; Leavitt, Nilgun

    1994-01-01

    Active sampling unit capable of detecting hydrazine and monomethyl hydrazine vapors at levels as low as 10 ppb in air developed. Includes detachable badge holder and pump which draws air through badge holder at selectable rate of 1 or 2 L/min. Coated strip in each badge designed to align with air passage in badge holder. Two types of badge holders constructed: one has open-face design for general monitoring of air in open spaces, while other has closed-face design with viewing window and intended for sampling through small openings to detect leaks.

  15. OPERATION MANUAL FOR AUTOMATIC DICHOTOMOUS SAMPLERS, APPLICATION TO BECKMAN DICHOTOMOUS SAMPLERS

    EPA Science Inventory

    Operation, calibration and maintenance procedures for the Beckman Automatic dichotomous sampler are described. This sampler is one of several currently available that simultaneously collect coarse and fine airborne particles. The manual is intended for use by technicians and oper...

  16. 30 CFR 74.3 - Sampler unit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Sampler unit. 74.3 Section 74.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.3 Sampler unit. A CMDPSU shall consist of: (a) A pump...

  17. A Redox Economical Synthesis of Bioactive 6,12-Guaianolides

    PubMed Central

    Wen, Bo; Hexum, Joseph K.; Widen, John C.

    2013-01-01

    Syntheses of two 6,12-guaianolide analogs are reported within. The scope of the tandem allylboration/lactonization chemistry is expanded to provide a functionalized alleneyne-containing α-methylene butyrolactone that undergoes a Rh(I)-catalyzed cyclocarbonylation reaction to afford a 5-7-5 ring system. The resulting cycloadducts bear a structural resemblance to other NF-κB inhibitors such as cumambrin A and indeed were shown to inhibit NF-κB signaling and cancer cell growth. PMID:23662902

  18. Surface Sampler Arm Acquiring Sample

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Operation of the surface sampler in obtaining Martian soil for Viking 2's molecular analysis experiment last Saturday (September 25) was closely monitored by one of the Lander cameras because of the precision required in trenching the small area--8 by 9 inches-surrounded by rocks. Dubbed 'Bonneville Salt Flats,' the exposure of thin crust appeared unique in contrast with surrounding materials and became a prime target for organic analysis in spite of potential hazards. Large rock in foreground is 8 inches high. At left, the sampler scoop has touched the surface, missing the rock at upper left by a comfortable 6 inches, and the backhoe has penetrated the surface about one-half inch. The scoop was then pulled back to sample the desired point and (second photo) the backhoe furrowed the surface pulling a piece of thin crust toward the spacecraft. The initial touchdown and retraction sequence was used to avoid a collision between a rock in the shadow of the arm and a plate joining the arm and scoop. The rock was cleared by 2 to 3 inches. The third picture was taken 8 minutes after the scoop touched the surface and shows that the collector head has acquired a quantity of soil. With surface sampler withdrawn (right), the foot-long trench is seen between the rocks. The trench is three inches wide and about 1 1/2 to 2 inches deep. The scoop reached to within 3 inches of the rock at far end of trench. Penetration appears to have left a cavernous opening roofed by the crust and only about one inch of undisturbed crust separates the deformed surface and the rock.

  19. SAVANNAH RIVER SITE TANK 18 AND TANK 19 WALL SAMPLER PERFORMANCE

    SciTech Connect

    Leishear, R.; Thaxton, D.; Minichan, R.; France, T.; Steeper, T.; Corbett, J.; Martin, B.; Vetsch, B.

    2009-12-19

    A sampling tool was required to evaluate residual activity ({mu}Curies per square foot) on the inner wall surfaces of underground nuclear waste storage tanks. The tool was required to collect a small sample from the 3/8 inch thick tank walls. This paper documents the design, testing, and deployment of the remotely operated sampling device. The sampler provides material from a known surface area to estimate the overall surface contamination in the tank prior to closure. The sampler consisted of a sampler and mast assembly mast assembly, control system, and the sampler, or end effector, which is defined as the operating component of a robotic arm. The mast assembly consisted of a vertical 30 feet long, 3 inch by 3 inch, vertical steel mast and a cantilevered arm hinged at the bottom of the mast and lowered by cable to align the attached sampler to the wall. The sampler and mast assembly were raised and lowered through an opening in the tank tops, called a riser. The sampler is constructed of a mounting plate, a drill, springs to provide a drive force to the drill, a removable sampler head to collect the sample, a vacuum pump to draw the sample from the drill to a filter, and controls to operate the system. Once the sampler was positioned near the wall, electromagnets attached it to the wall, and the control system was operated to turn on the drill and vacuum to remove and collect a sample from the wall. Samples were collected on filters in removable sampler heads, which were readily transported for further laboratory testing.

  20. 30 CFR 74.3 - Sampler unit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sampler unit. 74.3 Section 74.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.3...

  1. Quantitative organic vapor-particle sampler

    DOEpatents

    Gundel, Lara; Daisey, Joan M.; Stevens, Robert K.

    1998-01-01

    A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.

  2. 30 CFR 74.3 - Sampler unit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Sampler unit. 74.3 Section 74.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.3...

  3. 30 CFR 74.3 - Sampler unit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Sampler unit. 74.3 Section 74.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.3...

  4. 30 CFR 74.3 - Sampler unit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Sampler unit. 74.3 Section 74.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.3...

  5. Feasibility Study of Passive Aerosol Sampler for Bio-Agent Detection

    SciTech Connect

    Keating, G

    2003-03-05

    We propose to establish the feasibility of a passive aerosol sampler for bio-agent collection through laboratory experiments and theoretical analysis. The passive sampler, unlike the typical active sampler, does not require pumps and complex fixtures, and thereby allows for large-scale field monitoring not possible with current active samplers. We plan to conduct experiments using model (both biological and non-biological) aerosols generated in an instrumented test chamber and compare the particles collected on various passive samplers to conventional filter samplers, commercial aerosol measuring instruments and to conventional surface swipes. Theoretical analysis will be used to design prototype passive samplers and to compare experimental results with theory. A successful feasibility study will be used to seek outside funding for applications that will greatly enhance current LLNL programs such as NARAC's atmospheric dispersal modeling, NAI's programs in bioagent monitoring in public locations and fixed sampling stations, and EPD's environmental monitoring and decontamination research. In addition, the feasibility study will position us favorably for responding to new calls for proposals by NIH and EPA for large scale environmental studies.

  6. Performance evaluation of two personal bioaerosol samplers.

    PubMed

    Tolchinsky, Alexander D; Sigaev, Vladimir I; Varfolomeev, Alexander N; Uspenskaya, Svetlana N; Cheng, Yung S; Su, Wei-Chung

    2011-01-01

    In this study, the performance of two newly developed personal bioaerosol samplers for monitoring the level of environmental and occupational airborne microorganisms was evaluated. These new personal bioaerosol samplers were designed based on a swirling cyclone with recirculating liquid film. The performance evaluation included collection efficiency tests using inert aerosols, the bioaerosol survival test using viable airborne microorganism, and the evaluation of using non-aqueous collection liquid for long-period sampling. The test results showed that these two newly developed personal bioaerosol samplers are capable of doing high efficiency, aerosol sampling (the cutoff diameters are around 0.7 μm for both samplers), and have proven to provide acceptable survival for the collected bioaerosols. By using an appropriate non-aqueous collection liquid, these two personal bioaerosol samplers should be able to permit continuous, long-period bioaerosol sampling with considerable viability for the captured bioaerosols. PMID:22175872

  7. Field testing passive air samplers for current use pesticides in a tropical environment.

    PubMed

    Gouin, Todd; Wania, Frank; Ruepert, Clemens; Castillo, Luisa E

    2008-09-01

    Air was sampled for one year in the central valley of Costa Rica using an active high-volume sampler as well as passive samplers (PAS) based on polyurethane foam (PUF) disks and XAD-resin filled mesh cylinders. Extracts were analyzed for pesticides that are either banned or currently used in Costa Rican agriculture. Sampling rates for PUF-based passive air samplers, determined from the loss of depuration compounds spiked on the disks prior to deployment averaged 5.9 +/- 0.9 m3 x d(-1) and were higher during the windier dry season than during the rainy season. Sampling rates for the XAD-based passive sampler were determined from the slopes of linear relationships that were observed between the amount of pesticide sequestered in the resin and the length of deployment, which varied from 4 months to 1 year. Those sampling rates increased with decreasing molecular size of a pesticide, and their average of 2.1 +/- 1.5 m3 x d(-1) is higher than rates previously reported for temperate and polar sampling sites. Even though the trends of the sampling rate with molecular size and temperature are consistent with the hypothesis that molecular diffusion controls uptake in passive samplers, the trends are much more pronounced than a direct proportionality between sampling rate and molecular diffusivity would suggest. Air concentrations derived by the three sampling methods are within a factor of 2 of each other, suggesting that properly calibrated PAS can be effective tools for monitoring levels of pesticides in the tropical atmosphere. In particular, HiVol samplers, PUF-disk samplers, and XAD-based passive samplers are suitable for obtaining information on air concentration variability on the time scale of days, seasons and years, respectively. This study represents the first calibration study for the uptake of current use pesticides by passive air samplers. PMID:18800540

  8. 7 CFR 61.30 - Examination of sampler.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Examination of sampler. 61.30 Section 61.30... Cottonseed Samplers § 61.30 Examination of sampler. Each applicant for a license as a sampler and each... examination or test to show his ability properly to perform the duties for which he is applying for a...

  9. A passive sampler for atmospheric ozone

    SciTech Connect

    Grosjean, D.; Hisham, M.W.M. )

    1992-02-01

    A simple, cost-effective passive sampler has been developed for the determination of atmospheric ozone. This passive sampler is based on a colorant which fades upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Direct, on-site measurements are possible, and no chemical analyses are needed. Sampler design and validation studies have been carried out and included quantitative determination of color change vs exposure time (1-8 days), color change vs. ozone concentration (30-350 ppb), and response to changes in sampler configuration that modify the passive sampling rate. With indigo carmine as the colorant, the detection limits are 30 ppb. day and 120 ppb. day using a plastic grid and Teflon filter, respectively, as diffusion barriers. Interferences from nitrogen dioxide, formaldehyde and peroxyacetyl nitrate are 15, 4 and 16%, respectively, thus resulting in a negligible bias when measuring ozone in ambient air.

  10. DEVELOPMENT OF PERSONAL OZONE SAMPLERS: THREE APPROACHES

    EPA Science Inventory

    The investigators funded under the HEI ozone sampler program, Drs. Hackney, Yanagisawa, and Koutrakis, and their collaborators used different approaches to develop personal ozone samples that would be sensitive, accurate, and amenable to use in epidemiological studies.

  11. A plane-type soil sampler

    USGS Publications Warehouse

    Frey, Paul J.

    1963-01-01

    While studying the effects of pesticides on fish and their environment for the Bureau of Sport Fisheries and Wildlife, I have developed a soil sampler that will collect a thin uniform layer of sediment from pond and stream bottoms. As it is becoming increasingly important to analyze the residual deposits of pesticides in this shallow layer of soil in aquatic environments, it seems useful to describe the apparatus and compare it with other samplers.

  12. 40 CFR 721.524 - Alcohols, C6-12, ethoxylated, reaction product with maleic anhydride.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... New Uses for Specific Chemical Substances § 721.524 Alcohols, C6-12, ethoxylated, reaction product... chemical substance identified generically as alcohols, C6-12, ethoxylated, reaction product with maleic... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Alcohols, C6-12, ethoxylated,...

  13. 40 CFR 721.524 - Alcohols, C6-12, ethoxylated, reaction product with maleic anhydride.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... New Uses for Specific Chemical Substances § 721.524 Alcohols, C6-12, ethoxylated, reaction product... chemical substance identified generically as alcohols, C6-12, ethoxylated, reaction product with maleic... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Alcohols, C6-12, ethoxylated,...

  14. 40 CFR 721.524 - Alcohols, C6-12, ethoxylated, reaction product with maleic anhydride.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... New Uses for Specific Chemical Substances § 721.524 Alcohols, C6-12, ethoxylated, reaction product... chemical substance identified generically as alcohols, C6-12, ethoxylated, reaction product with maleic... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Alcohols, C6-12, ethoxylated,...

  15. 40 CFR 721.524 - Alcohols, C6-12, ethoxylated, reaction product with maleic anhydride.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... New Uses for Specific Chemical Substances § 721.524 Alcohols, C6-12, ethoxylated, reaction product... chemical substance identified generically as alcohols, C6-12, ethoxylated, reaction product with maleic... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Alcohols, C6-12, ethoxylated,...

  16. 40 CFR 721.524 - Alcohols, C6-12, ethoxylated, reaction product with maleic anhydride.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... New Uses for Specific Chemical Substances § 721.524 Alcohols, C6-12, ethoxylated, reaction product... chemical substance identified generically as alcohols, C6-12, ethoxylated, reaction product with maleic... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Alcohols, C6-12, ethoxylated,...

  17. 41 CFR 51-6.12 - Specification changes and similar actions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Specification changes and similar actions. 51-6.12 Section 51-6.12 Public Contracts and Property Management Other Provisions Relating to Public Contracts COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED 6-PROCUREMENT PROCEDURES § 51-6.12...

  18. Statistical analysis of the DWPF prototypic sampler

    SciTech Connect

    Postles, R.L.; Reeve, C.P.; Jenkins, W.J.; Bickford, D.F.

    1991-12-31

    The DWPF process will be controlled using assay measurements on samples of feed slurry. These slurries are radioactive, and thus will be sampled remotely. A Hydraguard{trademark} pump-driven sampler system will be used as the remote sampling device. A prototype Hydraguard{trademark} sampler has been studied in a full-scale mock-up of a DWPF process vessel. Two issues were of dominant interest: (1) what accuracy and precision can be provided by such a pump-driven sampler in the face of the slurry rheology; and, if the Hydraguard{trademark} sample accurately represents the slurry in its local area, (2) is the slurry homogeneous enough throughout for it to represent the entire vessel? To determine Hydraguard{trademark} Accuracy, a Grab Sampler of simpler mechanism was used as reference. This (Low) Grab Sampler was located as near to the intake port of the Hydraguard{trademark} as could be arranged. To determine Homogeneity, a second (High) Grab Sampler was located above the first. The data necessary to these determinations comes from the measurement system, so its important variables also affect the results. Thus, the design of the test involved not just Sampling variables, but also some of the Measurement variables as well. However, the main concern was the Sampler and not the Measurement System, so the test design included only such measurement variables as could not be circumvented (Vials, Dissolution Method, and Aliquoting). The test was executed by, or under the direct oversight of, expert technologists. It thus did not explore the many important particulars of ``routine`` plant operations (such as Remote Sample Preparation or Laboratory Shift Operation).

  19. Statistical analysis of the DWPF prototypic sampler

    SciTech Connect

    Postles, R.L.; Reeve, C.P.; Jenkins, W.J.; Bickford, D.F.

    1991-01-01

    The DWPF process will be controlled using assay measurements on samples of feed slurry. These slurries are radioactive, and thus will be sampled remotely. A Hydraguard{trademark} pump-driven sampler system will be used as the remote sampling device. A prototype Hydraguard{trademark} sampler has been studied in a full-scale mock-up of a DWPF process vessel. Two issues were of dominant interest: (1) what accuracy and precision can be provided by such a pump-driven sampler in the face of the slurry rheology; and, if the Hydraguard{trademark} sample accurately represents the slurry in its local area, (2) is the slurry homogeneous enough throughout for it to represent the entire vessel To determine Hydraguard{trademark} Accuracy, a Grab Sampler of simpler mechanism was used as reference. This (Low) Grab Sampler was located as near to the intake port of the Hydraguard{trademark} as could be arranged. To determine Homogeneity, a second (High) Grab Sampler was located above the first. The data necessary to these determinations comes from the measurement system, so its important variables also affect the results. Thus, the design of the test involved not just Sampling variables, but also some of the Measurement variables as well. However, the main concern was the Sampler and not the Measurement System, so the test design included only such measurement variables as could not be circumvented (Vials, Dissolution Method, and Aliquoting). The test was executed by, or under the direct oversight of, expert technologists. It thus did not explore the many important particulars of routine'' plant operations (such as Remote Sample Preparation or Laboratory Shift Operation).

  20. COMPARISON OF 24H AVERAGE VOC MONITORING RESULTS FOR RESIDENTIAL INDOOR AND OUTDOOR AIR USING CARBOPACK X-FILLED DIFFUSIVE SAMPLERS AND ACTIVE SAMPLING - A PILOT STUDY

    EPA Science Inventory

    Analytical results obtained by thermal desorption GC/MS for 24h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive samp...

  1. Application of a dialysis sampler to monitor phytoremediation processes.

    PubMed

    Jackson, W Andrew; Martino, Louis; Hirsh, Steven; Wrobel, John; Pardue, John H

    2005-08-01

    A cylindrical dialysis sampler (1.2 m in length; 5 cm in diameter) was designed and constructed to sample small-scale phytoremediation processes in the root zone of poplar trees. The study site was a 183-tree plantation of hybrid poplars located at Aberdeen Proving Ground, Maryland, at the J-Field Area of Concern. The grove was planted in 1996 to intercept a chlorinated solvent plume containing 1,1,2,2-tetrachloroethane (1,1,2,2-TeCA, trichloroethene (TCE) and daughter products. Two dialysis samplers were installed: one directly in the poplar grove (approximately 0.3 m from the trunk of a mature tree) and the other outside of the grove but in the plume. Data collected included concentrations of chlorinated VOCs, organic acids, chloroacetic acids, Cl-, and dissolved gases (ethane, ethene, CH4, CO2). At the control location, the VOC profile was dominated by cis-1,2-dichloroethene (cis-1,2-DCE) and trans-1,2-dichloroethene (trans-1,2-DCE) with concentrations ranging from 0.88-4.5 to 4.4-17.6 mg/L, respectively. Concentrations of VOCs were similar across the vertical profile. At the tree location, 1,1,2,2-TeCA and TCE were the dominant VOCs detected but as opposed to the control location were highly variable within the root zone, with the greatest variability associated with locations in the sampler where roots were observed. This highly variable profile at the tree location is indicative of VOC rhizosphere biodegradation and uptake near the active roots. This variability appears to be on the centimeter scale, emphasizing the importance of these high-resolution samplers for the study of rhizosphere influences. PMID:16418910

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR USE OF THE ACTIVE VOC SAMPLER FOR THE COLLECTION OF AIRBORNE VOCS AT FIXED INDOOR AND OUTDOOR SITES (UA-F-11.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...

  3. A passive sampler for airborne formaldehyde

    NASA Astrophysics Data System (ADS)

    Grosjean, Daniel; Williams, Edwin L.

    A simple, inexpensive passive sampler is described that is capable of reliable measurements of formaldehyde at the parts per billion (ppb) levels relevant to indoor and outdoor air quality. The passive sampler consists of a modified dual filter holder in which the upper stage serves as the diffusion barrier, the lower stage includes a 2,4-dinitrophenylhydrazine (DNPH)-coated filter which collects formaldehyde, and the space between the two stages serve as the diffusion gap. The measured sampling rate, 18.8 ± 1.8 ml min -1, was determined in experiments involving sampling of ppb levels of formaldehyde with the passive sampler and with DNPH-coated C 18 cartridges and agrees well with the value of 19.4 ± 2.0 ml min -1 calculated from theory. The measured sampling rate was independent of formaldehyde concentration (16-156 ppb) and sampling duration (1.5-72 h). The precision of the measurements for colocated passive samplers averaged 8.6% in purified and indoor air (office and museums) and 10.2% in photochemically polluted outdoor air. With a 1.2-μm pore size Teflon filter as the diffusion barrier, the detection limit is 32 ppb h, e.g. 4 ppb in an 8-h sample, 1.3 ppb in a 24-h sample, and so on. Perceived advantages and limitations of the sampler are discussed including flexibility, cost effectiveness and possible negative bias at high ambient levels of ozone.

  4. New approach to calibrating bed load samplers

    USGS Publications Warehouse

    Hubbell, D.W.; Stevens, H.H.; Skinner, J.V.; Beverage, J.P.

    1985-01-01

    Cyclic variations in bed load discharge at a point, which are an inherent part of the process of bed load movement, complicate calibration of bed load samplers and preclude the use of average rates to define sampling efficiencies. Calibration curves, rather than efficiencies, are derived by two independent methods using data collected with prototype versions of the Helley‐Smith sampler in a large calibration facility capable of continuously measuring transport rates across a 9 ft (2.7 m) width. Results from both methods agree. Composite calibration curves, based on matching probability distribution functions of samples and measured rates from different hydraulic conditions (runs), are obtained for six different versions of the sampler. Sampled rates corrected by the calibration curves agree with measured rates for individual runs.

  5. Coalescent genealogy samplers: windows into population history

    PubMed Central

    Kuhner, Mary K.

    2016-01-01

    Coalescent genealogy samplers attempt to estimate past qualities of a population, such as its size, growth rate, patterns of gene flow or time of divergence from another population, based on samples of molecular data. Genealogy samplers are increasingly popular because of their potential to disentangle complex population histories. In the last decade they have been widely applied to systems ranging from humans to viruses. Findings include detection of unexpected reproductive inequality in fish, new estimates of historical whale abundance, exoneration of humans for the prehistoric decline of bison and inference of a selective sweep on the human Y chromosome. This review summarizes available genealogy-sampler software, including data requirements and limitations on the use of each program. PMID:19101058

  6. Critical review of factors governing data quality of integrative samplers employed in environmental water monitoring.

    PubMed

    Roll, Isaac B; Halden, Rolf U

    2016-05-01

    Integrative sampling enables the collection of analyte mass from environmental liquids over extended timeframes from hours to months. While the incentives to complement or replace conventional, time-discrete sampling have been widely discussed, the data quality implications of employing alternative, integrative methods have not yet been systematically studied. A critical analysis of contemporary literature reports showed the data quality of integrative samplers, whether active-advection or passive-diffusion, to be governed by uncertainty in both sampling rate and analyte recovery. Derivation of two lumped parameters, representing the coefficient of accumulation (α) of a contaminant from an environmental fluid and the coefficient of subsequent recovery (ρ) of its mass from the sampler, produced a conceptual framework for quantifying error sources in concentration data derived from accumulative samplers. Whereas the precision associated with recovery was found to be fairly consistent across eight passive-diffusion and active-advection devices (averaging 5-16% relative standard deviation, RSD), active-advection samplers effectively improve precision in sampling rate (analyte uptake), as determined for two active-advection devices (2-7% average RSD) and five passive devices (12-42% average RSD). In summary, an approach is presented whereby the data quality implications of integrative sampler design can be compared, which can inform the selection, optimization, and development of sampling systems to complement the state of the art. PMID:26945963

  7. Technician Checks Soil Sampler on Viking Lander

    NASA Technical Reports Server (NTRS)

    1971-01-01

    A technician checks the soil sampler of the Viking lander. An arm will scoop up a sample of the Martian soil, empty it into a hopper on the lander which will route the sample to each of the three scientific instruments, biology, gas chromatograph/mass spectrometer and water analysis. NASA's Viking Lander was designed, fabricated, and tested by the Martin Marietta Corp. of Denver, Colorado, under the direction of the Viking Progect Office at Langley Research Center, Hampton, Virginia. The Lander drew heavily on the experience gained from the Ranger, Surveyor and the Apollo Programs in the areas of radar, altimeters, facsimile, cameras, soil samplers, landing gear, etc.

  8. Touch and Go Surface Sampler (TGSS)

    NASA Technical Reports Server (NTRS)

    Gorevan, S. P.; Rafeek, S.

    2001-01-01

    The Touch and Go Surface Sampler (TGSS) is a new class of planetary and small body sample acquisition tool that can be used for the surface exploration of Europa, Titan and comets. TGSS in its basic configuration consists of a high speed sampling head attached to the end of a flexible shaft. The sampling head consists of counter rotating cutters that rotates at speeds of 3000 to 15000 RPM. The attractive feature of this if touch and go type sampler is that there are no requirements for a lander type spacecraft. Additional information is contained in the original extended abstract.

  9. Compact semi-automatic incident sampler for personal monitoring of volatile organic compounds in occupational air.

    PubMed

    Solbu, Kasper; Hersson, Merete; Thorud, Syvert; Lundanes, Elsa; Nilsen, Terje; Synnes, Ole; Ellingsen, Dag; Molander, Paal

    2010-05-01

    Suddenly occurring and time limited chemical exposures caused by unintended incidents might pose a threat to many workers at various work sites. Monitoring of exposure during such occasional incidents is challenging. In this study a compact, low-weight and personal semi-automatic pumped unit for sampling of organic vapor phase compounds from occupational air during sporadic and suddenly occurring incidents has been developed, providing simple activation by the worker potentially subjected to the sudden occurring exposures when a trained occupational hygienist is not available. The sampler encompasses a tube (glass or stainless steel) containing an adsorbent material in combination with a small membrane pump, where the adsorbent is capped at both ends by gas tight solenoid valves. The sampler is operated by a conventional 9 V battery which tolerates long storage time (at least one year), and is activated by pulling a pin followed by automatic operation and subsequent closing of valves, prior to shipping to a laboratory. The adjustable sampling air flow rate and the sampling time are pre-programmed with a standard setting of 200 mL min(-1) and 30 min, respectively. The average airflow in the time interval 25-30 min compared to average airflow in the interval 2-7 min was 92-95% (n = 6), while the flow rate between-assay precisions (RSD) for six different samplers on three days each were in the range 0.5-3.7%. Incident sampler recoveries of VOCs from a generated VOC atmosphere relative to a validated standard method were between 95 and 102% (+/-4-5%). The valves that seal the sampler adsorbent during storage have been shown to prevent an external VOC atmosphere (500 mg m(-3)) to enter the adsorbent tube, in addition to that the sampler adsorbent is storable for at least one month due to absence of ingress of contaminants from internal parts. The sampler was also suitable for trapping of semi-volatile organophosphates. PMID:21491688

  10. AN ELECTROSTATIC SAMPLER FOR COLLECTING PM-2.5

    EPA Science Inventory

    Objective: Develop a new electrostatic sampler for collecting PM-2.5. This sampler will fit into the existing Federal Reference Method (FRM) sampling head, and will be used in place of the Teflon filter to collect the PM-2.5. The primary expected benefit of this sampler design...

  11. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade...

  12. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade...

  13. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade...

  14. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade...

  15. 21 CFR 884.1560 - Fetal blood sampler.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade...

  16. 21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Amniotic fluid sampler (amniocentesis tray). 884... Diagnostic Devices § 884.1550 Amniotic fluid sampler (amniocentesis tray). (a) Identification. The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from...

  17. 21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Amniotic fluid sampler (amniocentesis tray). 884... Diagnostic Devices § 884.1550 Amniotic fluid sampler (amniocentesis tray). (a) Identification. The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from...

  18. 21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Amniotic fluid sampler (amniocentesis tray). 884... Diagnostic Devices § 884.1550 Amniotic fluid sampler (amniocentesis tray). (a) Identification. The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from...

  19. 21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Amniotic fluid sampler (amniocentesis tray). 884... Diagnostic Devices § 884.1550 Amniotic fluid sampler (amniocentesis tray). (a) Identification. The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from...

  20. 21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Amniotic fluid sampler (amniocentesis tray). 884... Diagnostic Devices § 884.1550 Amniotic fluid sampler (amniocentesis tray). (a) Identification. The amniotic fluid sampler (amniocentesis tray) is a collection of devices used to aspirate amniotic fluid from...

  1. Student Sampler: Facts in Brief on North Carolina.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh.

    This information sampler was compiled to assist students in their study of North Carolina. Every year North Carolina students must complete a special project on their state. The sampler was designed to introduce students to the people, places, and events that have shaped North Carolina's history. Topics in the sampler include state symbols,…

  2. DEVELOPMENT AND EVALUATION OF AN AMBIENT VIABLE MICROBIAL AIR SAMPLER

    EPA Science Inventory

    Studies were performed to evaluate the suitability of cyclone scrubber samplers and a continuously wetted substrate for detection of several types of microorganisms. The samplers were evaluated in a dynamic aerosol chamber using all-glass impingers as reference samplers. Comparis...

  3. A new sampler for stratified lagoon chemical and microbiological assessments

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A water column sampler was needed to study stratification of nutrients and bacteria in a swine manure lagoon. Conventional samplers yielded shallow samples near the bank or required a boat. These limitations prompted development of a new sampler to collect at multiple depths with minimal disturbanc...

  4. Quantum Gibbs Samplers: The Commuting Case

    NASA Astrophysics Data System (ADS)

    Kastoryano, Michael J.; Brandão, Fernando G. S. L.

    2016-05-01

    We analyze the problem of preparing quantum Gibbs states of lattice spin Hamiltonians with local and commuting terms on a quantum computer and in nature. Our central result is an equivalence between the behavior of correlations in the Gibbs state and the mixing time of the semigroup which drives the system to thermal equilibrium (the Gibbs sampler). We introduce a framework for analyzing the correlation and mixing properties of quantum Gibbs states and quantum Gibbs samplers, which is rooted in the theory of non-commutative {{L}_p} spaces. We consider two distinct classes of Gibbs samplers, one of them being the well-studied Davies generator modelling the dynamics of a system due to weak-coupling with a large Markovian environment. We show that their spectral gap is independent of system size if, and only if, a certain strong form of clustering of correlations holds in the Gibbs state. Therefore every Gibbs state of a commuting Hamiltonian that satisfies clustering of correlations in this strong sense can be prepared efficiently on a quantum computer. As concrete applications of our formalism, we show that for every one-dimensional lattice system, or for systems in lattices of any dimension at temperatures above a certain threshold, the Gibbs samplers of commuting Hamiltonians are always gapped, giving an efficient way of preparing the associated Gibbs states on a quantum computer.

  5. Retained gas sampler system acceptance test report

    SciTech Connect

    Cannon, N.S., Westinghouse Hanford

    1996-07-18

    Acceptance test results for the Retained Gas Sampler System (RGSS) obtained in the 306E laboratory are reported. The RGSS will be utilized to retrieve and analyze samples from the Hanford flammable gas watch-list tanks to determine the quantity and chemistry of gases confined within the waste.

  6. Retained Gas Sampler Calibration and Simulant Tests

    SciTech Connect

    CRAWFORD, B.A.

    2000-01-05

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis.

  7. A Personal Nanoparticle Respiratory Deposition (NRD) Sampler

    PubMed Central

    Cena, Lorenzo G.; Anthony, T. Renée; Peters, Thomas M.

    2016-01-01

    A lightweight (60 g), personal nanoparticle respiratory deposition (NRD) sampler was developed to selectively collect particles smaller than 300 nm similar to their typical deposition in the respiratory tract. The sampler operates at 2.5 Lpm and consists of a respirable cyclone fitted with an impactor and a diffusion stage containing mesh screens. The cut-point diameter of the impactor was determined to be 300 nm with a sharpness σ = 1.53. The diffusion stage screens collect particles with an efficiency that matches the deposition efficiency of particles smaller than 300 nm in the respiratory tract. Impactor separation performance was unaffected by loading at typical workplace levels (p-value = 0.26). With chemical analysis of the diffusion media, the NRD sampler can be used to directly assess exposures to nanoparticles of a specific composition apart from other airborne particles. The pressure drop of the NRD sampler is sufficiently low to permit its operation with conventional, belt-mounted sampling pumps. PMID:21718022

  8. Releasable Asbestos Field Sampler (RAFS) Operation Manual

    EPA Science Inventory

    The Releasable Asbestos Field Sampler (RAFS) is a field instrument that provides an in-situ measurement of asbestos releasability from consistent and reproducible mechanical agitation of the source material such as soil. The RAFS was designed to measure concentration (asbestos st...

  9. South Philadelphia Passive Sampler and Sensor Study

    EPA Science Inventory

    Starting in June 2013, the United States Environmental Protection Agency (U.S. EPA) and the City of Philadelphia Air Measurements Services began collaborative research on the use of passive samplers (PSs) and stand-alone air measurement (SAM) systems to improve information on the...

  10. Quantum Gibbs Samplers: The Commuting Case

    NASA Astrophysics Data System (ADS)

    Kastoryano, Michael J.; Brandão, Fernando G. S. L.

    2016-06-01

    We analyze the problem of preparing quantum Gibbs states of lattice spin Hamiltonians with local and commuting terms on a quantum computer and in nature. Our central result is an equivalence between the behavior of correlations in the Gibbs state and the mixing time of the semigroup which drives the system to thermal equilibrium (the Gibbs sampler). We introduce a framework for analyzing the correlation and mixing properties of quantum Gibbs states and quantum Gibbs samplers, which is rooted in the theory of non-commutative {mathbb{L}_p} spaces. We consider two distinct classes of Gibbs samplers, one of them being the well-studied Davies generator modelling the dynamics of a system due to weak-coupling with a large Markovian environment. We show that their spectral gap is independent of system size if, and only if, a certain strong form of clustering of correlations holds in the Gibbs state. Therefore every Gibbs state of a commuting Hamiltonian that satisfies clustering of correlations in this strong sense can be prepared efficiently on a quantum computer. As concrete applications of our formalism, we show that for every one-dimensional lattice system, or for systems in lattices of any dimension at temperatures above a certain threshold, the Gibbs samplers of commuting Hamiltonians are always gapped, giving an efficient way of preparing the associated Gibbs states on a quantum computer.

  11. Outdoor field evaluation of passive tritiated water vapor samplers at Canadian power reactor sites.

    PubMed

    Wood, M J

    1996-02-01

    Tritium is one of several radioactive nuclides routinely monitored in and around CANDU (CANada Deuterium Uranium) power reactor facilities. Over the last ten years, passive samplers have replaced active sampling devices for sampling tritiated water vapor in the workplace at many CANDU stations. The potential of passive samplers for outdoor monitoring has also been realized. This paper presents the results of a 1-y field trial carried out at all five Canadian CANDU reactor sites. The results indicate that passive samplers can be used at most sampling locations to measure tritiated water vapor in air concentrations as low as 1 Bq m-3 over a 30-d sampling period. Only in one of the five sampling locations was poor agreement observed between active and passive monitoring data. This location, however, was very windy and it is suspected that the gusty winds were the source of the discrepancies observed. PMID:8567295

  12. Measurement of Aerosolization of Asbestos from Soil Using the Releasable Asbestos Field Sampler (RAFS)

    EPA Science Inventory

    Releasable Asbestos Field Sampler (RAFS) was designed to provide an alternative to activity-based sampling (ABS) for determining likely asbestos exposure resulting from activities at site with low contaminant levels. This paper presents a description of the RAFS device and a comp...

  13. Evaluation of passive diffusion bag samplers, dialysis samplers, and nylon-screen samplers in selected wells at Andersen Air Force Base, Guam, March-April 2002

    USGS Publications Warehouse

    Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.

    2003-01-01

    During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.

  14. 41 CFR 51-6.12 - Specification changes and similar actions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 41 Public Contracts and Property Management 1 2011-07-01 2009-07-01 true Specification changes and similar actions. 51-6.12 Section 51-6.12 Public Contracts and Property Management Other Provisions... Procurement List, including a change that involves the assignment of a new national stock number or...

  15. Photodegradation of PAHs in passive water samplers.

    PubMed

    Allan, Ian J; Christensen, Guttorm; Bæk, Kine; Evenset, Anita

    2016-04-15

    Losses of deuterated polycyclic aromatic hydrocarbons (PAHs) used as performance reference compounds (PRCs) in semipermeable membrane devices deployed at fifteen coastal sampling sites near Harstad harbour in Northern Norway were used to investigate photodegradation of these photosensitive compounds. Unusual PRC dissipation profiles, especially for samplers exposed <5m below the water surface are indicative of photodegradation. A strong correlation between loss rates for d12-chrysene and d12-benzo[e]pyrene with consistently higher losses of the latter was found. The observed photodegradation rates may be sufficiently high to impact PAH masses absorbed by a factor of two. This study demonstrates that photodegradation during exposure of passive water samplers needs to be taken into account, particularly with deployments close to the water surface, when using SPMD canisters, or when sampling in the Arctic. PMID:26876557

  16. Three-Wheel Brush-Wheel Sampler

    NASA Technical Reports Server (NTRS)

    Duckworth, Geoffrey A.; Liu, Jun; Brown, Mark G.

    2010-01-01

    A new sampler is similar to a common snow blower, but is robust and effective in sample collection. The brush wheels are arranged in a triangle shape, each driven by a brushless DC motor and planetary gearhead embedded in the wheel shaft. Its speed can be varied from 800 - 2,000 rpm, depending on the surface regolith resistance. The sample-collecting flow path, and internal features, are designed based on flow dynamics, and the sample-collecting rates have consistently exceeded the requirement under various conditions that span the range of expected surface properties. The brush-wheel sampler (BWS) is designed so that the flow channel is the main body of the apparatus, and links the brush-wheel assembly to the sample canister. The combination of the three brush wheels, the sample flow path, and the canister location make sample collection, storage, and transfer an easier task.

  17. CAM and stack air sampler design guide

    SciTech Connect

    Phillips, T.D.

    1994-05-13

    About 128 air samplers and CAMs presently in service to detect and document potential radioactive release from `H` and `F` area tank farm ventilation stacks are scheduled for replacement and/or upgrade by Projects S-5764, S-2081, S-3603, and S-4516. The seven CAMs scheduled to be upgraded by Project S-4516 during 1995 are expected to provide valuable experience for the three remaining projects. The attached document provides design guidance for the standardized High Level Waste air sampling system.

  18. Thin layer chromatography residue applicator sampler

    DOEpatents

    Nunes, Peter J.; Kelly, Fredrick R.; Haas, Jeffrey S.; Andresen, Brian D.

    2007-07-24

    A thin layer chromatograph residue applicator sampler. The residue applicator sampler provides for rapid analysis of samples containing high explosives, chemical warfare, and other analyses of interest under field conditions. This satisfied the need for a field-deployable, small, hand-held, all-in-one device for efficient sampling, sample dissolution, and sample application to an analytical technique. The residue applicator sampler includes a sampling sponge that is resistant to most chemicals and is fastened via a plastic handle in a hermetically sealed tube containing a known amount of solvent. Upon use, the wetted sponge is removed from the sealed tube and used as a swiping device across an environmental sample. The sponge is then replaced in the hermetically sealed tube where the sample remains contained and dissolved in the solvent. A small pipette tip is removably contained in the hermetically sealed tube. The sponge is removed and placed into the pipette tip where a squeezing-out of the dissolved sample from the sponge into the pipette tip results in a droplet captured in a vial for later instrumental analysis, or applied directly to a thin layer chromatography plate for immediate analysis.

  19. Trench Excavated By Viking 1 Surface Sampler

    NASA Technical Reports Server (NTRS)

    1976-01-01

    This image, received today, shows the trench excavated by Viking 1 surface sampler. The trench was dug by extending the surface sampler collection head in a direction from lower right toward the upper left and then withdrawing the surface sampler collector head. Lumpy piles of material at end of trench at lower right was pulled by plowing from trench by the backhoe which will be used to dig trenches later in the mission. Area around trench has ripple marks produced by Martian wind. The trench which was dug early on Sol 8, is about 3 inches wide, 2 inches deep and 6 inches long. Steep dark crater walls show the grains of the Martian surface material stick together (have adhesion). The doming of the surface at far end of the trench show the granular material is dense. The Martian surface material behaves somewhat like moist sand on Earth. Evidence from the trench indicate a sample was collected and delivered to the experiments after repeated tries. The biology experiment level full indicator indicates a sample was received for analysis. The X-Ray fluorescence experiment has no indication to show it received a sample. The GCMS experiment level full indicator suggests no sample was received but this matter is being investigated.

  20. Formed Core Sampler Hydraulic Conductivity Testing

    SciTech Connect

    Miller, D. H.; Reigel, M. M.

    2012-09-25

    A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.

  1. Meaningful, Authentic and Place-Based Informal Science Education for 6-12 Students

    NASA Astrophysics Data System (ADS)

    Ito, E.; Dalbotten, D. M.

    2014-12-01

    American Indians are underrepresented in STEM and especially in Earth sciences. They have the lowest high school graduation rate and highest unemployment. On the other hand, tribes are in search of qualified young people to work in geo- and hydro-technical fields to manage reservations' natural resources. Dalbotten and her collaborators at the Fond du Lac Band of Lake Superior Chippewa and local 6-12 teachers ran a place-based but non-themed informal monthly science camps (gidakiimanaaniwigamig) for 7 years starting 2003. Camps were held on reservation and some activities focused on observing seasonal changes. The students enjoyed coming to the camps but the camp activities went largely unnoticed by the reservation itself. For the last 5 years, we and the same cast of characters from the gidakiimanaaniwigamig camps ran a very place-based, research-based camp program, manoomin. The research was focused on manoomin (wild rice) which is a culturally important plant and food that grows in local lakes and wetlands. Manmade changes in hydrology, toxic metals from mining, and changing weather patterns due to climate change threaten this precious resource. Our plan was for 6-12 students to investigate the past, the present and the future conditions of manoomin on and around the reservation. It became clear by 3rd year that the research project, as conceived, was overly ambitious and could not be completed at the level we hoped in a camp setting (6 weekend camps = 6 full days per year). However, students felt that they were involved in research that was beneficial to their reservation, reported gaining self-confidence to pursue a career in science, and stated a desired to obtain a college degree. They also became aware of STEM employment opportunities on reservation that they could aim for. The camps also fostered a trusting relationship between researchers at Fond du Lac resource managers and the U. of MN. Based on these experiences, we proposed a new format for these

  2. Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.

    PubMed

    Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José

    2012-02-01

    Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations. PMID:22037834

  3. Environmental Curiosity Sampler 2: For Use with Environmental Study Areas in Illinois.

    ERIC Educational Resources Information Center

    Stehney, Virginia A.

    The Sampler provides ideas and lists resources for an interdisciplinary study of environment in terms of a person's immediate surroundings, distant sites, and facilities. Although it was developed for use by parents, teachers, youth group leaders, students, and interested individuals in the state of Illinois, many of the activities would be…

  4. Research highlights: natural passive samplers--plants as biomonitors.

    PubMed

    Lin, Vivian S

    2015-06-01

    In the past decade, interest in boosting the collection of data on environmental pollutants while reducing costs has spurred intensive research into passive samplers, instruments that monitor the environment through the free flow of chemical species. These devices, although relatively inexpensive compared to active sampling technologies, are often tailored for collection of specific contaminants or monitoring of a single phase, typically water or air. Plants as versatile, natural passive samplers have gained increased attention in recent years due to their ability to absorb a diverse range of chemicals from the air, water, and soil. Trees, lichens, and other flora have evolved exquisite biological features to facilitate uptake of nutrients and water from the ground and conduct gas exchange on an extraordinary scale, making them excellent monitors of their surroundings. Sampling established plant specimens in a region also provides both historical and spatial data on environmental contaminants at relatively low cost in a non-invasive manner. This Highlight presents several recent publications that demonstrate how plant biomonitoring can be used to map the distribution of a variety of pollutants and identify their sources. PMID:25980391

  5. NEW SOIL VOC SAMPLERS: EN CORE AND ACCU CORE SAMPLING/STORAGE DEVICES FOR VOC ANALYSIS

    SciTech Connect

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani Jr

    2006-06-01

    Soil sampling and storage practices for volatile organic analysis must be designed to minimize loss of volatile organic compounds (VOCs) from samples. The En Core{reg_sign} sampler is designed to collect and store soil samples in a manner that minimizes loss of contaminants due to volatilization and/or biodegradation. An ASTM International (ASTM) standard practice, D 6418, Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis, describes use of the En Core sampler to collect and store a soil sample of approximately 5 grams or 25 grams for volatile organic analysis and specifies sample storage in the En Core sampler at 4 {+-} 2 C for up to 48 hours; -7 to -21 C for up to 14 days; or 4 {+-} 2 C for up to 48 hours followed by storage at -7 to -21 C for up to five days. This report discusses activities performed during the past year to promote and continue acceptance of the En Core samplers based on their performance to store soil samples for VOC analysis. The En Core sampler is designed to collect soil samples for VOC analysis at the soil surface. To date, a sampling tool for collecting and storing subsurface soil samples for VOC analysis is not available. Development of a subsurface VOC sampling/storage device was initiated in 1999. This device, which is called the Accu Core{trademark} sampler, is designed so that a soil sample can be collected below the surface using a dual-tube penetrometer and transported to the laboratory for analysis in the same container. Laboratory testing of the current Accu Core design shows that the device holds low-level concentrations of VOCs in soil samples during 48-hour storage at 4 {+-} 2 C and that the device is ready for field evaluation to generate additional performance data. This report discusses a field validation exercise that was attempted in Pennsylvania in 2004 and activities being performed to plan and conduct a field validation study in 2006. A draft ASTM

  6. Evaluation of three portable samplers for monitoring airborne fungi

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Mishra, S. K.; Pierson, D. L.

    1996-01-01

    Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.

  7. A miniature flexible sampler for subsurface lunar exploration

    NASA Astrophysics Data System (ADS)

    Ling, Yun; Lu, Wei; Xiong, Pengwen; Song, Aiguo

    2016-06-01

    Lunar subsurface sampling is one of the critical technologies in the advancement of space exploration, and a lunar sampler with low weight, small volume, and low power consumption would significantly reduce the cost of space exploration. Thus, this paper proposes a novel miniature lunar sampler which adopts a flexible tape spring as its sampling arm. Compared with existing rigid-arm samplers, the proposed sampler has the merits of very low weight, reduced volume, and little power consumption. The mechanical design is illustrated in detail, the corresponding flexible kinematics model is built by considering flexibility compensation, and the working space of the sampler is depicted. The performance, e.g. the maximum acceleration, the maximum load capacity, and the sampling depth of the flexible arm, is analyzed through experiments, and each limit is established. In addition, the sampling process is demonstrated with the lab-based experiments, and the feasibility of the sampler is verified.

  8. A Comparison of Silicone-coated Paper Samplers and Polyethylene in Narragansett Bay

    NASA Astrophysics Data System (ADS)

    Dekany, V.; Lohmann, R.

    2008-12-01

    Accurately measuring dissolved concentrations of persistent organic pollutants (POPs) in surface waters remains a major challenge due to low concentrations, contamination concerns and sampling artifacts, such as sorption to dissolved organic carbon (DOC). Knowing dissolved concentrations of POPs, such as polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs), is key to understanding their fate in the ocean and their accumulation in the food-chain. The affinity of POPs towards hydrophobic matrices can be used to absorb the species of interest from their environment, a method known as passive sampling. As passive sampling devices (PSDs) rely on passive diffusion to accumulate analytes of interest, it is critical to better understand whether and when equilibrium has been achieved during field deployments. Silicone-based paper (41 g/m2 cellulose, 0.45-0.5 g Si/m2/side) and polyethylene samplers (PEs; 25 μm thickness) were compared in Narragansett Bay in July 2008. Samplers were deployed for 2, 4 and 8 days to derive [PAHs] in the water column. The effectiveness of each passive sampler was based on (i) the percent of performance reference compounds (PRCs) remaining in the device, (ii) the sorption capacity of the PSD for POPs, and (iii) successful field deployments in the Narragansett Bay water column. Samplers were analyzed for PAHs and PRCs (d-anthracene, d-benz[a]anthracene, and d-benzo[a]pyrene) by gas chromatography/mass spectrometry. As expected, faster loss rates were observed for lower molecular weight PRCs in both sampler types. The silicone paper samplers displayed faster equilibrium times than the PE samplers. The observed [PAHs] in the passive samplers were corrected for the temperature and salinity of the Bay water. The PRC loss rates were used to correct for non-equilibrium concentrations. Lastly, dissolved [PAHs] were calculated based on published PE-water equilibrium partitioning constants. Dissolved concentrations of PAHs derived

  9. Characterization of two passive air samplers for per- and polyfluoroalkyl substances.

    PubMed

    Ahrens, Lutz; Harner, Tom; Shoeib, Mahiba; Koblizkova, Martina; Reiner, Eric J

    2013-12-17

    Two passive air sampler (PAS) media were characterized under field conditions for the measurement of per- and polyfluoroalkyl substances (PFASs) in the atmosphere. The PASs, consisting of polyurethane foam (PUF) and sorbent-impregnated PUF (SIP) disks, were deployed for over one year in parallel with high volume active air samplers (HV-AAS) and low volume active air samplers (LV-AAS). Samples were analyzed for perfluoroalkyl carboxylic acids (PFCAs), perfluoroalkane sulfonic acids (PFSAs), fluorotelomer alcohols (FTOHs), fluorotelomer methacrylates (FTMACs), fluorotelomer acrylates (FTACs), perfluorooctane sulfonamides (FOSAs), and perfluorooctane sulfonamidoethanols (FOSEs). Sampling rates and the passive sampler medium (PSM)-air partition coefficient (KPSM-A) were calculated for individual PFASs. Sampling rates were similar for PFASs present in the gas phase and particle phase, and the linear sampling rate of 4 m(-3) d(-1) is recommended for calculating effective air sample volumes in the SIP-PAS and PUF-PAS for PFASs except for the FOSAs and FOSEs in the PUF-PAS. SIP disks showed very good performance for all tested PFASs while PUF disks were suitable only for the PFSAs and their precursors. Experiments evaluating the suitability of different isotopically labeled fluorinated depuration compounds (DCs) revealed that (13)C8-perfluorooctanoic acid (PFOA) was suitable for the calculation of site-specific sampling rates. Ambient temperature was the dominant factor influencing the seasonal trend of PFASs. PMID:24219299

  10. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  11. Earth Resources. A Case Study: Oil Sampler.

    ERIC Educational Resources Information Center

    California Integrated Waste Management Board, Sacramento.

    This document presents a sample of grades 6-12 science curriculum on Earth resources to promote scientific literacy. This natural resource-based curriculum uses an inquiry-based, hands-on approach and allows for community partnerships during student learning processes. Lessons plans included in this curriculum are divided into 4 categories: (1)…

  12. Whole-grain food consumption in Singaporean children aged 6-12 years.

    PubMed

    Neo, Jia En; Binte Mohamed Salleh, Saihah; Toh, Yun Xuan; How, Kesslyn Yan Ling; Tee, Mervin; Mann, Kay; Hopkins, Sinead; Thielecke, Frank; Seal, Chris J; Brownlee, Iain A

    2016-01-01

    Public health bodies in many countries are attempting to increase population-wide habitual consumption of whole grains. Limited data on dietary habits exist in Singaporean children. The present study therefore aimed to assess whole grain consumption patterns in Singaporean children and compare these with dietary intake, physical activity and health parameters. Dietary intake (assessed by duplicate, multipass, 24-h food recalls), physical activity (by questionnaire) and anthropometric measurements were collected from a cross-section of 561 Singaporean children aged 6-12 years. Intake of whole grains was evaluated using estimates of portion size and international food composition data. Only 38·3 % of participants reported consuming whole grains during the dietary data collection days. Median intake of whole grains in consumers was 15·3 (interquartile range 5·4-34·8) g/d. The most commonly consumed whole-grain food groups were rice (29·5 %), wholemeal bread (28·9 %) and ready-to-eat breakfast cereals (18·8 %). A significantly lower proportion of Malay children (seven out of fifty-eight; P < 0·0001) consumed whole grains than children of other ethnicities. Only 6 % of all children consumed the amount of whole grains most commonly associated with improved health outcomes (48 g/d). There was no relationship between whole grain consumption patterns and BMI, waist circumference or physical activity but higher whole grain intake was associated with increased fruit, vegetable and dairy product consumption (P < 0·001). These findings demonstrate that consumption of whole grain foods is low at a population level and infrequent in Singaporean children. Future drives to increase whole-grain food consumption in this population are likely to require input from multiple stakeholders. PMID:27547396

  13. Air sampler performance at Ford's farm range

    SciTech Connect

    Glissmeyer, J.A.; Johnston, J.W.

    1984-07-01

    An air-sampling system for a large-caliber depleted uranium (DU) penetrator firing range was tested. The objectives of the test were: to determine the bias between the monitoring readings and DU concentrations; and to determine if the target bay real-time monitor (RTM) tracks the decaying dust concentration. The test procedure was to operate total and respirable airborne particle samplers adjacent to the target bay monitors. A series of air samples was also taken after the test firings adjacent to the target bay RTM. Exhaust particle samples were analyzed for gross alpha, gross beta and uranium content. The target bay RTM correlated well (0.977) with the sequential samples. Average concentration from the RTM did not correlate with either the long-term total or respirable sampler DU concentrations. The monitor used to confirm a low dust concentration when the door is open correlated well (0.810) with the RTM; the other bay monitor did not. In the ventilation discharge, the long-term average monitor readings did not correlate with DU concentrations, probably due to levels near lower detection limits. Smearable surface-contamination samples showed highest contamination on the equipment, gravel floor and exhaust intake. The location air-intake contamination increased over the first 3 rounds. Contamination was reduced by a low-pressure water spray washdown to about the same concentration as often the second round, then remained at about twice the level. 2 references, 18 figures, 16 tables. (MF)

  14. COMPARISON OF INTEGRATED SAMPLERS FOR MASS AND COMPOSITION

    EPA Science Inventory

    The primary objective of EPA's Atlanta Supersites Project was to compare and evaluate a wide variety of samplers from time-integrated mass only monitors, to integrated and semi-continuous chemical speciation samplers, to single particle mass spectrometers. This paper will desc...

  15. Design and validation of a passive deposition sampler

    PubMed Central

    Yu, Chang-Ho; Mainelis, Gediminas; Chen, Lung Chi; Weisel, Clifford P.; Lioy, Paul J.

    2014-01-01

    A new, passive particle deposition air sampler, called the Einstein–Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr6+. The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs. PMID:22820464

  16. Electret-based passive dust sampler: sampling of organic dusts.

    PubMed

    Brown, R C; Hemingway, M A; Wake, D; Thorpe, A

    1996-09-01

    Passive samplers are light, convenient and cheap. However, the sample size tends to be small and a correlation exercise between the results of a passive sampler and a conventional sampler must be carried out. The design principles and mode of action of an electret-based passive dust sampler are described. The device captures dust particles at a rate independent of the velocity of air except when this is very low but dependent on the electrical properties of the dust being sampled. Experimental results are presented of measurements made in bakeries, pig farms, a dairy farm, an arable farm and a rubber-manufacturing plant. Correlation between measurements made with the passive sampler and measurements of inhalable dust performed by other means are reasonable. The results are interpreted in terms of the physical properties of the dust being sampled. PMID:8831282

  17. Siting Samplers to Minimize Expected Time to Detection

    SciTech Connect

    Walter, Travis; Lorenzetti, David M.; Sohn, Michael D.

    2012-05-02

    We present a probabilistic approach to designing an indoor sampler network for detecting an accidental or intentional chemical or biological release, and demonstrate it for a real building. In an earlier paper, Sohn and Lorenzetti(1) developed a proof of concept algorithm that assumed samplers could return measurements only slowly (on the order of hours). This led to optimal detect to treat architectures, which maximize the probability of detecting a release. This paper develops a more general approach, and applies it to samplers that can return measurements relatively quickly (in minutes). This leads to optimal detect to warn architectures, which minimize the expected time to detection. Using a model of a real, large, commercial building, we demonstrate the approach by optimizing networks against uncertain release locations, source terms, and sampler characteristics. Finally, we speculate on rules of thumb for general sampler placement.

  18. Development and evaluation of a water level proportional water sampler

    NASA Astrophysics Data System (ADS)

    Schneider, P.; Lange, A.; Doppler, T.

    2013-12-01

    We developed and adapted a new type of sampler for time-integrated, water level proportional water quality sampling (e.g. nutrients, contaminants and stable isotopes). Our samplers are designed for sampling small to mid-size streams based on the law of Hagen-Poiseuille, where a capillary (or a valve) limits the sampling aliquot by reducing the air flux out of a submersed plastic (HDPE) sampling container. They are good alternatives to battery-operated automated water samplers when working in remote areas, or at streams that are characterized by pronounced daily discharge variations such as glacier streams. We evaluated our samplers against standard automated water samplers (ISCO 2900 and ISCO 6712) during the snowmelt in the Black Forest and the Alps and tested them in remote glacial catchments in Iceland, Switzerland and Kyrgyzstan. The results clearly showed that our samplers are an adequate tool for time-integrated, water level proportional water sampling at remote test sites, as they do not need batteries, are relatively inexpensive, lightweight, and compact. They are well suited for headwater streams - especially when sampling for stable isotopes - as the sampled water is perfectly protected against evaporation. Moreover, our samplers have a reduced risk of icing in cold environments, as they are installed submersed in water, whereas automated samplers (typically installed outside the stream) may get clogged due to icing of hoses. Based on this study, we find these samplers to be an adequate replacement for automated samplers when time-integrated sampling or solute load estimates are the main monitoring tasks.

  19. Estimating FRM PM10 sampler performance characteristics using particle size analysis and collocated TSP and PM10 samplers: Cotton gins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In the US, regional air quality compliance with national ambient air quality standards (NAAQS) for particulate matter (PM) is based on concentration measurements taken by federal reference method (FRM) samplers. The EPA specifies the performance criteria for the FRM samplers. These criteria for the ...

  20. Monitoring solute fluxes: Integrating electrical resistivity with multi-compartment sampler techniques

    NASA Astrophysics Data System (ADS)

    Bloem, Esther; Fernandez, Perrine; French, Helen K.

    2016-04-01

    The impact of agriculture, industry, airport activities on soil and water quality is strongly influenced by soil heterogeneity. To improve risk assessment, monitoring, and treatment strategies, we require a better understanding of the effect of soil heterogeneity on contaminant movement and better methods for monitoring heterogeneous contaminated transport. Sufficient characterization of spatial and temporal distribution of contaminant transport requires measurements of water and solute fluxes at multiple locations with a high temporal resolution. During this presentation, we will show a newly developed instrument, which combines multi-compartment sampling with electrical resistivity measurements, to observe spatial and temporal fluxes of contaminants. Solute monitoring is often limited to observations of resident concentrations, while flux concentrations govern the movement of solutes in soils. Bloem et al. (2010) developed a multi-compartment sampler (MCS) which is capable of measuring fluxes at a high spatial resolution under natural conditions. The sampler is divided into 100 separate compartments of 31 by 31 mm. Flux data can be recorded at a high time resolution (every 5 minutes). Tracer leaching can be monitored by frequently sampling the collected leachate while leaving the sampler buried in situ. To optimize the monitoring of tracer leaching and measure real solute fluxes the multi-compartment sampler has been extended with 121 electrodes. The electrodes are mounted at each corner of each compartment to measure the electrical conductivity above each compartment while water percolates through the compartments. By using different electrode couples, the setup can also be used to image above the multi-compartment sampler. The instrument can be used for detailed studies both in the laboratory and in the field. For laboratory experiments a transparent column is used which fits perfect on top of the MCS. We present a selection of the integrated electrical

  1. Calibration of nylon organic chemical integrative samplers and sentinel samplers for quantitative measurement of pulsed aquatic exposures.

    PubMed

    Morrison, Shane A; Belden, Jason B

    2016-06-01

    Environmental exposures often occur through short, pulsed events; therefore, the ability to accurately measure these toxicologically-relevant concentrations is important. Three different integrative passive sampler configurations were evaluated under different flow and pulsed exposure conditions for the measurement of current-use pesticides (n=19), polyaromatic hydrocarbons (n=10), and personal care products (n=5) spanning a broad range of hydrophobicities (log Kow 1.5-7.6). Two modified POCIS-style samplers were investigated using macroporous nylon mesh membranes (35μm pores) and two different sorbent materials (i.e. Oasis HLB and Dowex Optipore L-493). A recently developed design, the Sentinel Sampler (ABS Materials), utilizing Osorb media enclosed within stainless steel mesh (145μm pores), was also investigated. Relatively high sampling rates (Rs) were achieved for all sampler configurations during the short eight-day exposure (4300-27mL/d). Under flow conditions, median Rs were approximately 5-10 times higher for POCIS-style samplers and 27 times higher for Sentinel Samplers, as compared to static conditions. The ability of samplers to rapidly measure hydrophobic contaminants may be a trade off with increased flow dependence. Analyte accumulation was integrative under pulsed and continuous exposures for POCIS-style samplers with mean difference between treatments of 11% and 33%; however, accumulation into Sentinel Samplers was more variable. Collectively, results show that reducing membrane limitations allows for rapid, integrative accumulation of a broad range of analytes even under pulsed exposures. As such, these sampler designs may be suitable for monitoring environmental substances that have short aquatic half-lives. PMID:27139214

  2. Improving the Convergence of Reversible Samplers

    NASA Astrophysics Data System (ADS)

    Rey-Bellet, Luc; Spiliopoulos, Konstantinos

    2016-06-01

    In Monte-Carlo methods the Markov processes used to sample a given target distribution usually satisfy detailed balance, i.e. they are time-reversible. However, relatively recent results have demonstrated that appropriate reversible and irreversible perturbations can accelerate convergence to equilibrium. In this paper we present some general design principles which apply to general Markov processes. Working with the generator of Markov processes, we prove that for some of the most commonly used performance criteria, i.e., spectral gap, asymptotic variance and large deviation functionals, sampling is improved for appropriate reversible and irreversible perturbations of some initially given reversible sampler. Moreover we provide specific constructions for such reversible and irreversible perturbations for various commonly used Markov processes, such as Markov chains and diffusions. In the case of diffusions, we make the discussion more specific using the large deviations rate function as a measure of performance.

  3. Improving the Convergence of Reversible Samplers

    NASA Astrophysics Data System (ADS)

    Rey-Bellet, Luc; Spiliopoulos, Konstantinos

    2016-08-01

    In Monte-Carlo methods the Markov processes used to sample a given target distribution usually satisfy detailed balance, i.e. they are time-reversible. However, relatively recent results have demonstrated that appropriate reversible and irreversible perturbations can accelerate convergence to equilibrium. In this paper we present some general design principles which apply to general Markov processes. Working with the generator of Markov processes, we prove that for some of the most commonly used performance criteria, i.e., spectral gap, asymptotic variance and large deviation functionals, sampling is improved for appropriate reversible and irreversible perturbations of some initially given reversible sampler. Moreover we provide specific constructions for such reversible and irreversible perturbations for various commonly used Markov processes, such as Markov chains and diffusions. In the case of diffusions, we make the discussion more specific using the large deviations rate function as a measure of performance.

  4. Improving the Precollegiate Curriculum on Latin America, Grades 6-12. Final Performance Report.

    ERIC Educational Resources Information Center

    Wirth, John D.

    The Latin America Project, which developed print and nonprint materials for use in grades 6-12, is described. The two-year effort was conducted in five phases: survey of existing materials; the development of curriculum units; review of curriculum by teachers attending summer institutes; field testing and evaluation; and dissemination. Titles of…

  5. 40 CFR 721.10559 - Morpholine, 4-C6-12 acyl derivs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subject to reporting. (1) The chemical substance identified as morpholine, 4-C6-12 acyl derivs. (PMN P-06...) through (h) are applicable to manufacturers, importers, and processors of this substance. (2) Limitations... SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific...

  6. University of Chicago School Mathematics Project 6-12 Curriculum. What Works Clearinghouse Intervention Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2011

    2011-01-01

    The "University of Chicago School Mathematics Project ("UCSMP") 6-12 Curriculum" is a series of yearlong courses--(1) Transition Mathematics; (2) Algebra; (3) Geometry; (4) Advanced Algebra; (5) Functions, Statistics, and Trigonometry; and (6) Precalculus and Discrete Mathematics--emphasizing problem solving, real-world applications, and the use…

  7. Health Problems in the Classroom 6-12: An A-Z Reference Guide for Educators.

    ERIC Educational Resources Information Center

    Huffman, Dolores M.; Fontaine, Karen Lee; Price, Bernadette K.

    This guide provides a resource for middle and high school teachers, teacher aides, administrators, and educators, covering health problems that affect students in grades 6-12. The handbook alphabetically lists the most current health concerns for this age group. Part 1, "Health Issues in the Classroom," includes (1) "Health, Illness, and…

  8. Teens on Target Violence Prevention Curriculum for Grades 6-12.

    ERIC Educational Resources Information Center

    Becker, Marla G.; Calhoun, Deane

    This curriculum is designed to help schools implement programs to prevent violence among students in grades 6-12. It is a six-session, school based curriculum intended for adolescents who are living in communities experiencing high rates of violence. It is facilitated by trained Teens on Target (TNT) members/peer educators, young people who are…

  9. Acoustically enriching, large-depth aquatic sampler.

    PubMed

    Jonsson, Jonas; Ogden, Sam; Johansson, Linda; Hjort, Klas; Thornell, Greger

    2012-05-01

    In marine biology, it is useful to collect water samples when exploring the distribution and diversity of microbial communities in underwater environments. In order to provide, e.g., a miniaturized submersible explorer with the capability of collecting microorganisms, a compact sample enrichment system has been developed. The sampler is 30 mm long, 15 mm wide, and just a few millimetres thick. Integrated in a multilayer steel, polyimide and glass construction is a microfluidic channel with piezoelectric transducers, where microorganism and particle samples are collected and enriched, using acoustic radiation forces for gentle and labelless trapping. High-pressure, latchable valves, using paraffin as the actuation material, at each end of the microfluidic channel keep the collected sample pristine. A funnel structure raised above the surface of the device directs water into the microfluidic channel as the vehicle propels itself or when there is a flow across its hull. The valves proved leak proof to a pressure of 2.1 MPa for 19 hours and momentary pressures of 12.5 MPa, corresponding to an ocean depth of more than 1200 metres. By reactivating the latching mechanism, small leakages through the valves could be remedied, which could thus increase the leak-less operational time. Fluorescent particles, 1.9 μm in diameter, were successfully trapped in the microfluidic channel at flow rates up to 15 μl min(-1), corresponding to an 18.5 cm s(-1) external flow rate of the sampler. In addition, liquid-suspended GFP-marked yeast cells were successfully trapped. PMID:22422039

  10. Musculoskeletal extremity injuries in a cohort of schoolchildren aged 6-12: a 2.5-year prospective study.

    PubMed

    Jespersen, E; Rexen, C T; Franz, C; Møller, N C; Froberg, K; Wedderkopp, N

    2015-04-01

    The objectives of this prospective school cohort study were to describe the epidemiology of diagnosed musculoskeletal extremity injuries and to estimate the injury incidence rates in relation to different settings, different body regions and injury types. In all, 1259 schoolchildren, aged 6-12, were surveyed weekly during 2.5 years using a new method of automated mobile phone text messaging asking questions on the presence of any musculoskeletal problems. All injuries were clinically diagnosed. Physical activity was measured from text messaging and accelerometers. A total number of 1229 injuries were diagnosed; 180 injuries in the upper extremity and 1049 in the lower extremity, with an overall rate of 1.59 injuries per 1000 physical activity units [95% confidence interval (CI) 1.50-1.68]. Upper extremities accounted for a rate of 0.23 (95% CI 0.20-0.27) and lower extremities accounted for 1.36 (95% CI 1.27-1.44). This study has added a wide overall perspective to the area concerning incidence and incidence rates of musculoskeletal extremity injuries in schoolchildren aged 6-12 years, including severe and less severe, traumatic, and overuse injuries. The understanding of injury epidemiology in children is fundamental to the acknowledgement and insurance of the appropriate prevention and treatment. PMID:24472003

  11. Laboratory evaluation of the CIP 10 personal dust sampler.

    PubMed

    Gero, A; Tomb, T

    1988-06-01

    The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow through the sampler is induced by the third stage, which is a rotating collector cup that contains a fine grade sponge. Laboratory tests were conducted in a dust chamber using aerosols of Arizona road dust, coal dust and silica dust. Aerosol concentrations measured with the CIP 10 were compared to those measured with the coal mine dust personal sampler unit used in the United States. The results of this study showed that aerosol concentrations measured with the CIP 10 were linearly related to those obtained with the coal mine dust personal sampler. The relationship, however, was dependent on preselector configuration and aerosol characteristics. The collection medium allows some small particles (less than 3 microns) to pass through the sampler without being collected. As much as 13% (by weight) of the aerosol that penetrated through the preseparating stages was exhausted from the sampler. PMID:2840817

  12. Evaluation of portable air samplers for monitoring airborne culturable bacteria

    NASA Technical Reports Server (NTRS)

    Mehta, S. K.; Bell-Robinson, D. M.; Groves, T. O.; Stetzenbach, L. D.; Pierson, D. L.

    2000-01-01

    Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

  13. An inexpensive sampler for obtaining bulk sediment cores

    NASA Astrophysics Data System (ADS)

    Cooper, Charles M.; Schiebe, Frank R.; Ritchie, Jerry C.

    1991-09-01

    A large-volume core sampler for sediment—muck substrates is described. The sampler can acquire a discrete sediment core of 10 cm in diameter and up to 1.5 m long. Such samplers are needed to collect the volume necessary for analysis of sediments for contaminants, bulk density, or radioactive dating. The sampler consists of a 1- to 2-m length of PVC pipe mounted below a threaded metal pipe air exhaust—intake assembly. This assembly is quick-connected to standard threaded lengths (300 cm) of water pipe (2 cm diam) or electrical conduit so that bottom sediments in water depths of up to 10 m can be sampled. The core sampler is hand-operated and pushed into bottom sediments from a boat. It does not have to be triggered remotely because of the one-way modified check valve in the air exhaust—intake assembly. After the sampler is extracted from the sediment, the extension handle can be quickly removed for ease of sampler handling, and the core can be extruded from the PVC tube by air pressure.

  14. A second look at the Palmes' diffusive sampler.

    PubMed

    Busbin, Dainnya D; Feigley, Charles E; Underhill, Dwight W; Salzberg, Deborah

    2006-10-01

    The Palmes' tube, the first diffusive sampler incorporating a fixed path length, has received wide usage for the sampling of a large number of gaseous pollutants. But despite numerous previous studies, questions remain regarding the accuracy of these inexpensive, simple-to-construct, open-ended samplers. Here the mass transfer resistance in a Palmes' diffusive sampler was measured using the loss of cyclohexane from a Palmes' tube containing liquid cyclohexane at its base. The average loss rates, at factorial combinations of five air incidence angles evenly spaced from 270 degrees to 90 degrees, and five air speeds from 0.5 m/sec to 2.5 m/sec ranged from 46% to 121% higher than rates calculated from the physical dimensions of the sampler, proving the need to calibrate these samplers rather than relying on a theoretical calculation. The mass transfer resistance was nearly constant when the airflow was perpendicular to the sampler and sufficiently high to avoid stagnation, a finding that may explain the widespread acceptance of the results obtained using this sampler. PMID:17063865

  15. Field testing of a personal size-selective bioaerosol sampler.

    PubMed

    Kenny, L C; Bowry, A; Crook, B; Stancliffe, J D

    1999-08-01

    Existing samplers for the collection of bioaerosols have been designed with the aim of maintaining biological stability of the collected material, and in general do not select particles in accordance with international conventions for aerosol sampling. Many have uncharacterised sampling efficiencies and few are designed as personal samplers. If standard personal dust samplers are used for bioaerosols the viability of collected microorganisms may be compromised by dehydration. The objective of this study was to evaluate a novel personal bioaerosol sampler designed to collect the inhalable dust fraction and further subdivide the sample into thoracic and respirable fractions. The new sampler was tested to see whether it enhanced the survival of the collected microorganisms, and was assessed for ease of use in the field and in subsequent laboratory analyses. A number of occupation-related field sites were selected where large concentrations of bioaerosols were to be expected. The prototype sampler was found to be simple to use. Analysis could be carried out with similar efficiency either with all three fractions together for a total count, or separately for size selective data. The sampler performed at least as well as the standard IOM filter method but with the added advantage of size fractionation. The field trials showed that for sampling periods lasting several hours, microorganism survival within the sampler was adequate for culture and identification of the organisms present. This new sampler is now commercially available. In addition to bioaerosol sampling, the principle of size selective sampling using porous foams can be applied to other occupational hygiene problems, and also to indoor air monitoring of PM10 and PM2.5 concentrations. PMID:10518465

  16. A new sampler for stratified lagoon chemical and microbiological assessments.

    PubMed

    McLaughlin, M R; Brooks, J P; Adeli, A

    2014-07-01

    A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates. PMID:24549945

  17. Efficiency tests of samplers for microbiological aerosols, a review

    NASA Technical Reports Server (NTRS)

    Henningson, E.; Faengmark, I.

    1984-01-01

    To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.

  18. 7 CFR 800.185 - Duties of official personnel and warehouse samplers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Duties of official personnel and warehouse samplers... official personnel and warehouse samplers. (a) General. Official personnel and warehouse samplers shall... of § 800.161. (d) Scope of operations. Official personnel and warehouse samplers shall operate...

  19. 41 Active Learning Strategies for the Inclusive Classroom, Grades 6-12

    ERIC Educational Resources Information Center

    Casale-Giannola, Diane; Green, Linda Schwartz

    2012-01-01

    Motivating adolescents to learn can be a challenge! Often distracted and easily bored, these kids are also critical thinkers capable of thriving in the classroom while learning 21st century skills. How do we hold their attention and develop their abilities? Research shows that all students--regardless of learning style, disability category, or…

  20. A high-yield sampler for toxicological characterization of complex mixtures in combustion effluents.

    PubMed Central

    Kruzel, E L; Lafleur, A L; Braun, A G; Longwell, J P; Thilly, W G; Peters, W A

    1991-01-01

    Combustion sampling for toxicological assessment often requires that large (greater than 100 mg) lots of complex organic mixtures of wide volatility range be rapidly recovered from high temperature gases without contamination. A new sampler, meeting these criteria for studies of public health interest, has been developed and demonstrated. The device provides high sampling rates and intimate contacting of the samples stream with large volumes of a well-cooled, liquid solvent, dichloromethane (DCM). This promotes rapid organics dissolution from carrier gas and particulates and prompt dilution and quenching of the resulting solution, resulting in high organics collection efficiencies with minimal DCM losses. Solvent separation then remits large quantities of concentrated organics for chemical analysis and toxicological testing. One- to seven-hour interrogations of in-flame, post-flame, and flue gas regions gave 50- to 250-mg yields of complex organic mixtures. In side-by-side sampling of combustion exhaust, the DCM sampler provided higher yields of DCM solubles (identified with complex organic mixtures) and of S. typhimuirim mutagens (active without exogenous metabolizing agents) than did a filter/polymeric sorbent bed sampling train. The new sampler also collects polar and high volatile hydrocarbons such as benzaheyde, pentadiyne, m- and p-diethynyl-benzene, and 1-hexen-3,5-diyne. Nitration of naphthalene and pyrene in DCM solution (1 mg/mL each) was less than 1 part in 10(7) after a 345-min exposure to a bubbling flow of moist N2/air mixture (1:1 v/v) containing 107 ppm NO and 1.5 ppm NO2, indicating that for these condition a DCM sampler should resist artifactual nitration of aromatics. However, because of the very high bacterial mutagenicity of some nitroaromatics and the wide range of sampling conditions of environmental interest, nitration and all artifacts must still be scrutinized when using the DCM sampler. The DCM sampler is expected to contribute to public

  1. [CrIII8MII6]12+ Coordination Cubes (MII=Cu, Co)**

    PubMed Central

    Sanz, Sergio; O'Connor, Helen M; Pineda, Eufemio Moreno; Pedersen, Kasper S; Nichol, Gary S; Mønsted, Ole; Weihe, Høgni; Piligkos, Stergios; McInnes, Eric J L; Lusby, Paul J; Brechin, Euan K

    2015-01-01

    [CrIII8MII6]12+ (MII=Cu, Co) coordination cubes were constructed from a simple [CrIIIL3] metalloligand and a “naked” MII salt. The flexibility in the design proffers the potential to tune the physical properties, as all the constituent parts of the cage can be changed without structural alteration. Computational techniques (known in theoretical nuclear physics as statistical spectroscopy) in tandem with EPR spectroscopy are used to interpret the magnetic behavior. PMID:25891167

  2. The MAGIC meteoric smoke particle sampler

    NASA Astrophysics Data System (ADS)

    Hedin, Jonas; Giovane, Frank; Waldemarsson, Tomas; Gumbel, Jörg; Blum, Jürgen; Stroud, Rhonda M.; Marlin, Layne; Moser, John; Siskind, David E.; Jansson, Kjell; Saunders, Russell W.; Summers, Michael E.; Reissaus, Philipp; Stegman, Jacek; Plane, John M. C.; Horányi, Mihály

    2014-10-01

    Between a few tons to several hundred tons of meteoric material enters the Earth's atmosphere each day, and most of this material is ablated and vaporized in the 70-120 km altitude region. The subsequent chemical conversion, re-condensation and coagulation of this evaporated material are thought to form nanometre sized meteoric smoke particles (MSPs). These smoke particles are then subject to further coagulation, sedimentation and global transport by the mesospheric circulation. MSPs have been proposed as a key player in the formation and evolution of ice particle layers around the mesopause region, i.e. noctilucent clouds (NLC) and polar mesosphere summer echoes (PMSE). MSPs have also been implicated in mesospheric heterogeneous chemistry to influence the mesospheric odd oxygen/odd hydrogen (Ox/HOx) chemistry, to play an important role in the mesospheric charge balance, and to be a significant component of stratospheric aerosol and enhance the depletion of O3. Despite their apparent importance, little is known about the properties of MSPs and none of the hypotheses can be verified without direct evidence of the existence, altitude and size distribution, shape and elemental composition. The aim of the MAGIC project (Mesospheric Aerosol - Genesis, Interaction and Composition) was to develop an instrument and analysis techniques to sample for the first time MSPs in the mesosphere and return them to the ground for detailed analysis in the laboratory. MAGIC meteoric smoke particle samplers have been flown on several sounding rocket payloads between 2005 and 2011. Several of these flights concerned non-summer mesosphere conditions when pure MSP populations can be expected. Other flights concerned high latitude summer conditions when MSPs are expected to be contained in ice particles in the upper mesosphere. In this paper we present the MAGIC project and describe the MAGIC MSP sampler, the measurement procedure and laboratory analysis. We also present the attempts to

  3. Fluidized Bed Asbestos Sampler Design and Testing

    SciTech Connect

    Karen E. Wright; Barry H. O'Brien

    2007-12-01

    A large number of samples are required to characterize a site contaminated with asbestos from previous mine or other industrial operations. Current methods, such as EPA Region 10’s glovebox method, or the Berman Elutriator method are time consuming and costly primarily because the equipment is difficult to decontaminate between samples. EPA desires a shorter and less costly method for characterizing soil samples for asbestos. The objective of this was to design and test a qualitative asbestos sampler that operates as a fluidized bed. The proposed sampler employs a conical spouted bed to vigorously mix the soil and separate fine particulate including asbestos fibers on filters. The filters are then analyzed using transmission electron microscopy for presence of asbestos. During initial testing of a glass prototype using ASTM 20/30 sand and clay fines as asbestos surrogates, fine particulate adhered to the sides of the glass vessel and the tubing to the collection filter – presumably due to static charge on the fine particulate. This limited the fines recovery to ~5% of the amount added to the sand surrogate. A second prototype was constructed of stainless steel, which improved fines recovery to about 10%. Fines recovery was increased to 15% by either humidifying the inlet air or introducing a voltage probe in the air space above the sample. Since this was not a substantial improvement, testing using the steel prototype proceeded without using these techniques. Final testing of the second prototype using asbestos suggests that the fluidized bed is considerably more sensitive than the Berman elutriator method. Using a sand/tremolite mixture with 0.005% tremolite, the Berman elutriator did not segregate any asbestos structures while the fluidized bed segregated an average of 11.7. The fluidized bed was also able to segregate structures in samples containing asbestos at a 0.0001% concentration, while the Berman elutriator method did not detect any fibers at this

  4. Study of fifteen respirable aerosol samplers used in occupational hygiene.

    PubMed

    Görner, P; Wrobel, R; Micka, V; Skoda, V; Denis, J; Fabriès, J F

    2001-01-01

    European and international standards lay down criteria for the size-selective aerosol sampling in occupational hygiene. Aerosol samplers are supposed to match these target sampling criteria. This study focused on 15 aerosol samplers used to sample the conventional respirable fraction. An aerodynamic particle sizer (APS) method was used to measure the sampling efficiency of the samplers in a low-velocity wind tunnel. Polydisperse coal dust was generated as the test aerosol. The data were fitted by an appropriate mathematical model. For some instruments the results show serious deviations from the conventional target curve, whereas other devices meet the convention quite well. The flow rate of certain cyclone-separator-based instruments was optimized to adjust their sampling efficiency. The mass concentration bias and accuracy of the samplers were calculated for a number of ranges of particle size distributions of aerosols commonly found in industrial workplaces. Finally, the performance of each sampler was evaluated using bias and accuracy maps. Most of these samplers are suitable for sampling the CEN-ISO-ACGIH respirable fraction of aerosols, but several require modification of the flow rate. For real industrial situations, the rough knowledge of the aerosol size distribution can guide the choice of an appropriate sampling technique. PMID:11137698

  5. Transient digitizer with displacement current samplers

    DOEpatents

    McEwan, T.E.

    1996-05-21

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board. 16 figs.

  6. Transient digitizer with displacement current samplers

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.

  7. Permeation absorption sampler with multiple detection

    DOEpatents

    Zaromb, Solomon

    1990-01-01

    A system for detecting analytes in air or aqueous systems includes a permeation absorption preconcentrator sampler for the analytes and analyte detectors. The preconcentrator has an inner fluid-permeable container into which a charge of analyte-sorbing liquid is intermittently injected, and a fluid-impermeable outer container. The sample is passed through the outer container and around the inner container for trapping and preconcentrating the analyte in the sorbing liquid. The analyte can be detected photometrically by injecting with the sorbing material a reagent which reacts with the analyte to produce a characteristic color or fluorescence which is detected by illuminating the contents of the inner container with a light source and measuring the absorbed or emitted light, or by producing a characteristic chemiluminescence which can be detected by a suitable light sensor. The analyte can also be detected amperometrically. Multiple inner containers may be provided into which a plurality of sorbing liquids are respectively introduced for simultaneously detecting different analytes. Baffles may be provided in the outer container. A calibration technique is disclosed.

  8. A Gibbs sampler for multivariate linear regression

    NASA Astrophysics Data System (ADS)

    Mantz, Adam B.

    2016-04-01

    Kelly described an efficient algorithm, using Gibbs sampling, for performing linear regression in the fairly general case where non-zero measurement errors exist for both the covariates and response variables, where these measurements may be correlated (for the same data point), where the response variable is affected by intrinsic scatter in addition to measurement error, and where the prior distribution of covariates is modelled by a flexible mixture of Gaussians rather than assumed to be uniform. Here, I extend the Kelly algorithm in two ways. First, the procedure is generalized to the case of multiple response variables. Secondly, I describe how to model the prior distribution of covariates using a Dirichlet process, which can be thought of as a Gaussian mixture where the number of mixture components is learned from the data. I present an example of multivariate regression using the extended algorithm, namely fitting scaling relations of the gas mass, temperature, and luminosity of dynamically relaxed galaxy clusters as a function of their mass and redshift. An implementation of the Gibbs sampler in the R language, called LRGS, is provided.

  9. Understanding the rates of nonpolar organic chemical accumulation into passive samplers deployed in the environment: Guidance for passive sampler deployments.

    PubMed

    Apell, Jennifer N; Tcaciuc, A Patricia; Gschwend, Philip M

    2016-07-01

    Polymeric passive samplers have become a common method for estimating freely dissolved concentrations in environmental media. However, this approach has not yet been adopted by investigators conducting remedial investigations of contaminated environmental sites. Successful adoption of this sampling methodology relies on an understanding of how passive samplers accumulate chemical mass as well as developing guidance for the design and deployment of passive samplers. Herein, we outline the development of a simple mathematical relationship of the environmental, polymer, and chemical properties that control the uptake rate. This relationship, called a timescale, is then used to illustrate how each property controls the rate of equilibration in samplers deployed in the water or in the sediment. Guidance is also given on how to use the timescales to select an appropriate polymer, deployment time, and suite of performance reference compounds. Integr Environ Assess Manag 2016;12:486-492. © 2015 SETAC. PMID:26426907

  10. Back injuries in a cohort of schoolchildren aged 6-12: A 2.5-year prospective study.

    PubMed

    Franz, C; Jespersen, E; Rexen, C T; Leboeuf-Yde, C; Wedderkopp, N

    2016-08-01

    The aims of this prospective school cohort study were to describe the epidemiology of diagnosed back pain in childhood, classified as either nontraumatic or traumatic back injury, and to estimate the association with physical activity in different settings. Over 2.5 years, 1240 children aged 6-12 years were surveyed weekly using mobile text messages to ask about the presence or absence of back pain. Pain was clinically diagnosed and injuries were classified using the International Classification of Diseases version 10. Physical activity data were obtained from text messages and accelerometers. Of the 315 back injuries diagnosed, 186 injuries were nontraumatic and 129 were traumatic. The incidence rate ratio was 1.5 for a nontraumatic back injury compared with a traumatic injury. The overall estimated back injury incidence rate was 0.20 per 1000 physical activity units (95% confidence interval 0.18-0.23). The back injury incidence rates were higher for sports when exposure per 1000 physical activity units was taken into consideration and especially children horse-riding had a 40 times higher risk of sustaining a traumatic back injury compared to the risk during non-organized leisure time physical activity. However, the reasonably low injury incidence rates support the recommendations of children continuously being physically active. PMID:26130046

  11. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers

    PubMed Central

    2016-01-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF–PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA’s National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF–PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  12. A Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers.

    PubMed

    Herkert, Nicholas J; Martinez, Andres; Hornbuckle, Keri C

    2016-07-01

    We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, predicts the Veff as a function of physical-chemical properties of each compound and meteorology from the closest Integrated Surface Database (ISD) data set obtained through NOAA's National Centers for Environmental Information (NCEI). The model was developed to be user-friendly, only requiring basic Matlab knowledge. To illustrate the effectiveness of the model, we evaluated three independent data sets of airborne PCBs simultaneously collected using passive and active samplers: at sites in Chicago, Lancaster, UK, and Toronto, Canada. The model provides Veff values comparable to those using depuration compounds and calibration against active samplers, yielding an average congener specific concentration method ratio (active/passive) of 1.1 ± 1.2. We applied the model to PUF-PAS samples collected in Chicago and show that previous methods can underestimate concentrations of PCBs by up to 40%, especially for long deployments, deployments conducted under warming conditions, and compounds with log Koa values less than 8. PMID:26963482

  13. Deep-Sea Hydrothermal-Vent Sampler

    NASA Technical Reports Server (NTRS)

    Behar, Alberto E.; Venkateswaran, Kasthur; Matthews, Jaret B.

    2008-01-01

    An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral

  14. A Simple and Disposable Sampler for Inhalable Aerosol.

    PubMed

    L'Orange, Christian; Anderson, Kimberly; Sleeth, Darrah; Anthony, T Renée; Volckens, John

    2016-03-01

    The state-of-the-art for personal sampling for inhalable aerosol hazards is constrained by issues of sampler cost and complexity; these issues have limited the adoption and use of some samplers by practicing hygienists. Thus, despite the known health effects of inhalable aerosol hazards, personal exposures are routinely assessed for only a small fraction of the at-risk workforce. To address the limitations of current technologies for inhalable aerosol sampling, a disposable inhalable aerosol sampler was developed and evaluated in the laboratory. The new sampler is designed to be less expensive and simpler to use than existing technologies. The sampler incorporates a lightweight internal capsule fused to the sampling filter. This capsule-filter assembly allows for the inclusion of particles deposited on the internal walls and inlet, thus minimizing the need to wash or wipe the interior sampling cassette when conducting gravimetric analyses. Sampling efficiency and wall losses were tested in a low-velocity wind tunnel with particles ranging from 9.5 to 89.5 μm. The results were compared to the proposed low-velocity inhalability criterion as well as published data on the IOM sampler. Filter weight stability and time-to-equilibrium were evaluated as these factors affect the practicality of a design. Preliminary testing of the new sampler showed good agreement with both the IOM and the proposed low-velocity inhalability curve. The capsule and filter assemblies reached equilibrium within 25h of manufacturing when conditioned at elevated temperatures. After reaching equilibrium, the capsule-filter assemblies were stable within 0.01mg. PMID:26467335

  15. SEM/EDS of Submicron and Coarse PM Using Modified Passive Aerosol Sampler Substrates

    NASA Astrophysics Data System (ADS)

    Wagner, J.; Wang, Z.; Willis, B.; Casuccio, G.

    2008-12-01

    Deployment of multiple UNC Passive Aerosol Samplers is an inexpensive and unobtrusive technique for assessing airborne particulate matter (PM) exposure and spatial variability. Computer-controlled SEM/EDS (Scanning Electron Microscopy / Energy-Dispersive X-ray Spectroscopy) is used to measure the deposited particle mass and chemistry. A deposition velocity model is used to obtain ambient PM and elemental size distributions. Previous results have correlated well with active sampler results in environments dominated by coarse mineral dusts. To accurately measure submicron and carbonaceous aerosols, an improved collection substrate is needed. Previous studies used a double-sided carbon adhesive tab, which was ideal for coarse PM but under-detected submicron PM. One promising alternative is polycarbonate (PC) filter substrates. Another is transmission electron microscope (TEM) grids with formvar films mounted over holes drilled in the samplers. Preliminary tests of PC filters and TEM grid substrates, including tests in areas with smoke aerosols, exhibited substantial submicron aerosol and differing elemental size distributions. Detailed qualitative and quantitative evidence shows that the PC filters retained coarse PM well and yielded improved submicron PM imaging. TEM grids yield the best imaging and chemistry of submicron carbonaceous PM, but potentially the poorest retention of coarse PM. PM and elemental size distributions are presented for collocated passive samplers using the three substrate types, in both indoor and outdoor environments. Several methods are proposed to further optimize passive sampling of both submicron and coarse PM. Although this work was reviewed by EPA and approved for publication, it may not necessarily reflect official Agency policy.

  16. Electronic properties and carrier mobilities of 6,6,12-graphyne nanoribbons

    SciTech Connect

    Ding, Heyu; Huang, Yuanhe; Bai, Hongcun

    2015-07-15

    Structures, stabilities, electronic properties and carrier mobilities of 6,6,12-graphyne nanoribbons (GyNRs) with armchair and zigzag edges are investigated using the self-consistent field crystal orbital method based on density functional theory. It is found that the 1D GyNRs are more stable than the 2D 6,6,12-graphyne sheet in the view of the Gibbs free energy. The stabilities of these GyNRs decrease as their widths increase. The calculated band structures show that all these GyNRs are semiconductors and that dependence of band gaps on the ribbon width is different from different types of the GyNRs. The carrier mobility was calculated based on the deformation theory and effective mass approach. It is found that the carrier mobilities of these GyNRs can reach the order of 10{sup 5} cm{sup 2} V {sup –1}s{sup –1} at room temperature and are comparable to those of graphene NRs. Moreover, change of the mobilities with change of the ribbon width is quite different from different types of the GyNRs.

  17. Vibrational and thermodynamic properties of α-, β-, γ-, and 6, 6, 12-graphyne structures.

    PubMed

    Perkgöz, Nihan Kosku; Sevik, Cem

    2014-05-01

    Electronic, vibrational, and thermodynamic properties of different graphyne structures, namely α-, β-, γ-, and 6, 6, 12-graphyne, are investigated through first principles-based quasi-harmonic approximation by using phonon dispersions predicted from density-functional perturbation theory. Similar to graphene, graphyne was shown to exhibit a structure with extraordinary electronic features, mechanical hardness, thermal resistance, and very high conductivity from different calculation methods. Hence, characterizing its phonon dispersions and vibrational and thermodynamic properties in a systematic way is of great importance for both understanding its fundamental molecular properties and also figuring out its phase stability issues at different temperatures. Thus, in this research work, thermodynamic stability of different graphyne allotropes is assessed by investigating vibrational properties, lattice thermal expansion coefficients, and Gibbs free energy. According to our results, although the imaginary vibrational frequencies exist for β-graphyne, there is no such a negative behavior for α-, γ-, and 6, 6, 12-graphyne structures. In general, the Grüneisen parameters and linear thermal expansion coefficients of these structures are calculated to be rather more negative when compared to those of the graphene structure. In addition, the predicted difference between the binding energies per atom for the structures of graphene and graphyne points out that graphyne networks have relatively lower phase stability in comparison with the graphene structures. PMID:24737253

  18. Performance of high flow rate samplers for respirable particle collection.

    PubMed

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P; Slaven, James; Harper, Martin

    2010-08-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins-Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 microm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2-11 times based on gravimetric analysis. Dust loading inside the

  19. Performance of High Flow Rate Samplers for Respirable Particle Collection

    PubMed Central

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P.; Slaven, James; Harper, Martin

    2010-01-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high

  20. INSTRUCTIONS FOR OPERATING LBL FORMALDEHYDE SAMPLER

    SciTech Connect

    Fanning, L.Z.; Allen, J.R.; Miksch, R.R.

    1981-09-01

    The LBL formaldehyde sampler consists of two parts: 1) a pump box and 2) a small refrigerator housing sampling bubblers. The pump box contains two pumps, a timer, a flow controller, an electrical cord, and a ten-foot piece of tubing to connect the refrigerator to the pump box. The small refrigerator contains four columns of bubbler sampling trains attached to a metal plate. Two sampling trains each are plumbed in parallel to two sampling ports on the back of the refrigerator. The two sampling lines supplied are to be attached to these ports to allow two locations to be sampled at once (usually one indoor and one outdoor). The refrigerator also contains a rack for holding bubbler tubes. In the sampling process, air is drawn through a sampling line attached to the fitting at the back of the refrigerator and into a prlmary bubbler containing a trapping solution. This trapping solution can be distilled water or an aqueous solution of some compound that reacts with formaldehyde. From this bubbler the air goes through a second bubbler containing the same trapping solution as the first bubbler. (To maintain sample integrity, all parts that the air sample contacts are made of Teflon, polypropylene, and stainless steel.) The air then goes into the third bubbler, which contains no liquid. This bubbler contains a hypodermic needle that serves as a flow-control orifice. The hypodermic needle, in conjunction with the flow controller in the pump box, ensures a constant a flow rate. The refrigerator contains four columns of these sets of three bubblers. After samples have been collected, the bubbler bottoms are detached and the contents of the first and second bubblers in each column are poured together, capped, and labeled. The use of a refrigerated primary and secondary bubbler whose contents are combined at the end of a sampling period ensures 95% collection efficiency. After the bubbler tubes are capped and labeled, they are stored either in the rack supplied in the

  1. Thickness and material selection of polymeric passive samplers for polycyclic aromatic hydrocarbons in water: Which more strongly affects sampler properties?

    PubMed

    Belles, Angel; Alary, Claire; Mamindy-Pajany, Yannick

    2016-07-01

    Three configurations of single-phase polymer passive samplers made of polyoxymethylene (POM), silicone rubber, and polyethylene (PE) were simultaneously calibrated in laboratory experiments by determining their partitioning coefficients and the POM diffusion coefficients and by validating a kinetic accumulation model. In addition, the performance of each device was evaluated under field conditions. With the support of the developed model, the device properties are discussed with regard to material selection and polymer thickness. The results show that a sampler's properties, such as its concentration-averaging period and ability to sample a large amount of polycyclic aromatic hydrocarbons, are widely affected by material selection. Sampler thickness also allows modulation of the properties of the device but with a much lower magnitude. Selection of the appropriate polymer and/or thickness allows samplers to be adapted either for quick equilibration or for the kinetic accumulation regime and promotes either membrane or water boundary layer control of the kinetic accumulation. In addition, membrane-controlled or equilibrated compounds are quantified with greater accuracy because they are not corrected by the performance reference compounds approach. However, the averaged concentrations cannot be assessed when compounds reach equilibrium in the sampler, whereas membrane-controlled devices remaining in the kinetic accumulation regime provide averaged concentrations without requiring performance reference compound correction; detection limits are then increased because of the higher mass transfer resistance of the membrane. Environ Toxicol Chem 2016;35:1708-1717. © 2015 SETAC. PMID:26647116

  2. A Gibbs sampler for conductivity imaging and other inverse problems

    NASA Astrophysics Data System (ADS)

    Fox, Colin

    2012-10-01

    Gibbs samplers have many desirable theoretical properties, but also have the pesky requirement that conditional distributions be available. We show how conditional densities can be evaluated for the posterior distribution in conductivity imaging - virtually for free in coordinate directions and very cheaply in other `special' directions. The analysis actually applies to a broad class of non-invasive imaging techniques that utilize strong scattering of energy, and leads to efficient iterative algorithms whether implementing inference or optimization. The resulting Gibbs sampler draws an independent conductivity image in only a little more compute time than required for optimization.

  3. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  4. Monitoring of jökulhlaups and element fluxes in proglacial Icelandic rivers using osmotic samplers

    NASA Astrophysics Data System (ADS)

    Jones, Morgan T.; Gałeczka, Iwona M.; Gkritzalis-Papadopoulos, Athanasios; Palmer, Martin R.; Mowlem, Matthew C.; Vogfjörð, Kristín; Jónsson, Þorsteinn; Gislason, Sigurður R.

    2015-01-01

    The quantification of volatile emissions from volcanoes is an integral part of understanding magmatic systems, with the exsolution and extent of volcanic degassing having a large impact on the nature of an eruption. Measurements of volatiles have traditionally focused on gas emissions into the atmosphere, but volatiles can also become dissolved in proximal water bodies en route to the surface. Thus the monitoring of rivers draining active volcanic areas can provide insights to identifying changes in activity. This process is particularly important for sub-glacial volcanoes in Iceland, where much of the volatile release is transported within glacial outbreak floods, termed jökulhlaups. Monitoring and characterising these phenomena is hampered by the dependence on spot sampling of stochastic events under challenging field conditions, which often leads to bias in the collected data. A recent technological advance is the osmotic sampler, an electricity-free pump that continuously collects water that can subsequently be divided into time-averaged samples. This technique allows for continued and unsupervised deployment of a sampler for weeks to months, representing a cost-efficient form of chemical monitoring. In this study we deployed osmotic samplers in two rivers in southern Iceland. Skálm is a proglacial river from Mýrdalsjökull glacier and Katla volcano, while Skaftá is a larger drainage system from the western part of Vatnajökull glacier. Both rivers are prone to jökulhlaups from geothermal and volcanic sources, and a small jökulhlaup of geothermal origin occurred during the second deployment in Skaftá in January 2014. The two deployments show that osmotic samplers are capable of delivering accurate chemical data in turbulent conditions for several key elements. Total dissolved fluxes for the deployment at Skaftá are calculated to be Na = 9.9 tonnes/day, Mg = 10.5 t/d, Si = 34.7 t/d, Cl = 11.0 t/d, Ca = 31.6 t/d, DIC = 50.8 t/d, and SO4 = 28.3 t/d, with

  5. Passive Samplers for Investigations of Air Quality: Method Description, Implementation, and Comparison to Alternative Sampling Methods

    EPA Science Inventory

    This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...

  6. Determining Passive Sampler Partition Coefficients for Dissolved-phase Organic Contaminants

    EPA Science Inventory

    Passive samplers are used for environmental and analytical purposes to measure dissolved nonionic organic contaminants (NOCs) by absorption from a contaminated medium into a clean phase, usually in the form of a synthetic organic film. Recently developed passive sampler techniqu...

  7. Selecting Performance Reference Compounds (PRCS) for Low Density Polyethylene Passive Samplers

    EPA Science Inventory

    Use of equilibrium passive samplers for performing aquatic environmental monitoring at contaminated sites is becoming more common. However, a current challenge in passive sampling is determining when equilibrium is achieved between the sampler, target contaminants, and environm...

  8. Enhanced surface sampler and process for collection and release of analytes

    SciTech Connect

    Addleman, Raymond S; Atkinson, David A; Bays, John T; Chouyyok, Wilaiwan; Cinson, Anthony D; Ewing, Robert G; Gerasimenko, Aleksandr A

    2015-02-03

    An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

  9. Draft Genome Sequence of Herbaspirillum lusitanum P6-12, an Endophyte Isolated from Root Nodules of Phaseolus vulgaris

    PubMed Central

    Weiss, Vinícius Almir; Faoro, Helisson; Tadra-Sfeir, Michelle Zibbetti; Raittz, Roberto Tadeu; de Souza, Emanuel Maltempi; Monteiro, Rose Adele; Cardoso, Rodrigo Luis Alves; Wassem, Roseli; Chubatsu, Leda Satie; Huergo, Luciano Fernandes; Müller-Santos, Marcelo; Steffens, Maria Berenice Reynaud; Rigo, Liu Un; Pedrosa, Fábio de Oliveira

    2012-01-01

    Herbaspirillum lusitanum strain P6-12 (DSM 17154) is, so far, the only species of Herbaspirillum isolated from plant root nodules. Here we report a draft genome sequence of this organism. PMID:22815451

  10. FIELD EVALUATION OF A HIGH-VOLUME DICHOTOMOUS SAMPLER

    EPA Science Inventory

    This study presents the field evaluation of a high-volume dichotomous sampler that collects coarse (PM10-2.5) and fine (PM2.5) particulate matter. The key feature of this device is the utilization of a round-nozzle virtual impactor with a 50% cutpoint at 2.5 5m to split PM10 into...

  11. Wind tunnel evaluation of the RAAMP sampler. Final report

    SciTech Connect

    Vanderpool, R.W.; Peters, T.M.

    1994-11-01

    Wind tunnel tests of the Department of Energy RAAMP (Radioactive Atmospheric Aerosol Monitoring Program) monitor have been conducted at wind speeds of 2 km/hr and 24 km/hr. The RAAMP sampler was developed based on three specific performance objectives: (1) meet EPA PM10 performance criteria, (2) representatively sample and retain particles larger than 10 {micro}m for later isotopic analysis, (3) be capable of continuous, unattended operation for time periods up to 2 months. In this first phase of the evaluation, wind tunnel tests were performed to evaluate the sampler as a potential candidate for EPA PM10 reference or equivalency status. As an integral part of the project, the EPA wind tunnel facility was fully characterized at wind speeds of 2 km/hr and 24 km/hr in conjunction with liquid test aerosols of 10 {micro}m aerodynamic diameter. Results showed that the facility and its operating protocols met or exceeded all 40 CFR Part 53 acceptance criteria regarding PM10 size-selective performance evaluation. Analytical procedures for quantitation of collected mass deposits also met 40 CFR Part 53 criteria. Modifications were made to the tunnel`s test section to accommodate the large dimensions of the RAAMP sampler`s instrument case.

  12. South Philadelphia Passive Sampler and Sensor Study: Interim Report

    EPA Science Inventory

    Starting in June 2013, the United States Environmental Protection Agency (U.S. EPA) and the City of Philadelphia Air Measurements Services began collaborative research on the use of passive samplers (PSs) and stand-alone air measurement (SAM) systems to improve information on the...

  13. South Philadelphia Passive Sampler and Sensor Study - Interim Report

    EPA Science Inventory

    Starting in the June 2013, the U.S. EPA and the City of Philadelphia Air Measurements Services (AMS) began a collaborative research project to investigate how sensor-based, stand-alone air measurements (SAMs) and passive samplers (PSs) can help improve information on air pollutan...

  14. Fluidic Sampler. Tanks Focus Area. OST Reference No. 2007

    SciTech Connect

    None, None

    1999-09-01

    Problem Definition; Millions of gallons of radioactive and hazardous wastes are stored in underground tanks across the U.S. Department of Energy (DOE) complex. To manage this waste, tank operators need safe, cost-effective methods for mixing tank material, transferring tank waste between tanks, and collecting samples. Samples must be collected at different depths within storage tanks containing various kinds of waste including salt, sludge, and supernatant. With current or baseline methods, a grab sampler or a core sampler is inserted into the tank, waste is maneuvered into the sample chamber, and the sample is withdrawn from the tank. The mixing pumps in the tank, which are required to keep the contents homogeneous, must be shut down before and during sampling to prevent airborne releases. These methods are expensive, require substantial hands-on labor, increase the risk of worker exposure to radiation, and often produce nonrepresentative and unreproducible samples. How It Works: The Fluidic Sampler manufactured by AEA Technology Engineering Services, Inc., enables tank sampling to be done remotely with the mixing pumps in operation. Remote operation minimizes the risk of exposure to personnel and the possibility of spills, reducing associated costs. Sampling while the tank contents are being agitated yields consistently homogeneous, representative samples and facilitates more efficient feed preparation and evaluation of the tank contents. The above-tank portion of the Fluidic Sampler and the replacement plug and pipework that insert through the tank top are shown.

  15. 7 CFR 52.29 - Who may become licensed sampler.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... MARKETING ACT OF 1946 PROCESSED FRUITS AND VEGETABLES, PROCESSED PRODUCTS THEREOF, AND CERTAIN OTHER PROCESSED FOOD PRODUCTS 1 Regulations Governing Inspection and Certification Licensing of Samplers and... processed products under the regulations in this part except as to identification and condition of...

  16. POLLUTANT SAMPLER FOR MEASUREMENTS OF ATMOSPHERIC ACIDIC DRY DEPOSITION

    EPA Science Inventory

    An acidic pollutant sampler for dry deposition monitoring has been designed and evaluated in laboratory and field studies. The system, which is modular and simple to operate, samples gaseous HNO3, NH3, SO2 and NO2 and particulate SO4(-2), NO3(1-) and NH4(1+) and is made of Teflon...

  17. PARTICULATE ORGANIC CARBON MEASUREMENTS COLLECTED WITH LOW FLOW PERSONAL SAMPLERS

    EPA Science Inventory

    EPA's National Exposure Research Laboratory and the Research Triangle Institute (RTI) have conducted a particulate matter (PM) personal exposure study in Research Triangle Park, NC. Particulate carbon was sampled with pre-fired quartz filters using low flow PM2.5 samplers (2 L...

  18. Student Sampler: Facts in Brief on North Carolina

    ERIC Educational Resources Information Center

    North Carolina Department of Public Instruction, 2006

    2006-01-01

    This student sampler has been compiled to assist North Carolina students (4th and 8th grade) in their study of North Carolina. It is designed to introduce them to the people, places and events that have shaped North Carolina history. Topics include state symbols, descriptions of the state flag, and seal, the lyrics to the state song, and the…

  19. Polyurethane foam (PUF) passive samplers for monitoring phenanthrene in stormwater.

    PubMed

    Dou, Yueqin; Zhang, Tian C; Zeng, Jing; Stansbury, John; Moussavi, Massoum; Richter-Egger, Dana L; Klein, Mitchell R

    2016-04-01

    Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) for sampling phenanthrene (PHE) in highway stormwater runoff and BMPs. Tests were conducted using batch reactors, glass-tube columns, and laboratory-scale BMPs (bioretention cells). Results indicate that sorption for PHE by PUF is mainly linearly relative to time, and the high sorption capacity allows the PUF passive sampler to monitor stormwater events for months or years. The PUF passive samplers could be embedded in BMPs for monitoring influent and effluent PHE concentrations. Models developed to link the results of batch and column tests proved to be useful for determining removal or sorption parameters and performance of the PUF-PSs. The predicted removal efficiencies of BMPs were close to the real values obtained from the control columns with errors ranging between -8.46 and 1.52%. This research showed that it is possible to use PUF passive samplers for sampling stormwater and monitoring the performance of stormwater BMPs, which warrants the field-scale feasibility studies in the future. PMID:26942631

  20. DICHOTOMOUS SAMPLERS MODIFIED FOR USE WITH ELECTRON MICROSCOPY

    EPA Science Inventory

    Large sulfate artifacts up to 2 um in diameter were observed by scanning electron microscopy for the fine particle fraction collected in dichotomous samplers. he artifacts were attributed to small liquid particles that piled up on the filter, coalesced, and later dried as larger ...

  1. Ammonia concentration modeling based on retained gas sampler data

    SciTech Connect

    Terrones, G.; Palmer, B.J.; Cuta, J.M.

    1997-09-01

    The vertical ammonia concentration distributions determined by the retained gas sampler (RGS) apparatus were modeled for double-shell tanks (DSTs) AW-101, AN-103, AN-104, and AN-105 and single-shell tanks (SSTs) A-101, S-106, and U-103. One the vertical transport of ammonia in the tanks were used for the modeling. Transport in the non-convective settled solids and floating solids layers is assumed to occur primarily via some type of diffusion process, while transport in the convective liquid layers is incorporated into the model via mass transfer coefficients based on empirical correlations. Mass transfer between the top of the waste and the tank headspace and the effects of ventilation of the headspace are also included in the models. The resulting models contain a large number of parameters, but many of them can be determined from known properties of the waste configuration or can be estimated within reasonable bounds from data on the waste samples themselves. The models are used to extract effective diffusion coefficients for transport in the nonconvective layers based on the measured values of ammonia from the RGS apparatus. The modeling indicates that the higher concentrations of ammonia seen in bubbles trapped inside the waste relative to the ammonia concentrations in the tank headspace can be explained by a combination of slow transport of ammonia via diffusion in the nonconvective layers and ventilation of the tank headspace by either passive or active means. Slow transport by diffusion causes a higher concentration of ammonia to build up deep within the waste until the concentration gradients between the interior and top of the waste are sufficient to allow ammonia to escape at the same rate at which it is being generated in the waste.

  2. Multilevel samplers as microcosms to assess microbial response to biostimulation.

    PubMed

    Baldwin, B R; Peacock, A D; Park, M; Ogles, D M; Istok, J D; McKinley, J P; Resch, C T; White, D C

    2008-01-01

    Passive multilevel samplers (MLS) containing a solid matrix for microbial colonization were used as in situ microcosms in conjunction with a push-pull biostimulation experiment designed to promote biological U(VI) and Tc(VII) reduction. MLS were deployed at 24 elevations in the injection well and two downgradient wells to investigate the spatial variability in microbial community composition and growth prior to and following biostimulation. The microbial community was characterized by real-time quantitative polymerase chain reaction (Q-PCR) quantification of bacteria, NO(3)(-)-reducing bacteria (nirS and nirK), delta-proteobacteria, Geobacter sp., and methanogens (mcrA). Pretest cell densities were low overall but varied substantially with significantly greater bacterial populations detected at circumneutral pH (t-test, alpha= 0.05), suggesting carbon substrate and low pH limitations of microbial activity. Although pretest cell densities were low, denitrifying bacteria were dominant members of the microbial community. Biostimulation with an ethanol-amended ground water resulted in concurrent NO(3)(-) and Tc(VII) reduction, followed by U(VI) reduction. Q-PCR analysis of MLS revealed significant (1 to 2 orders of magnitude, Mann-Whitney U-test, alpha= 0.05) increases in cell densities of bacteria, denitrifiers, delta-proteobacteria, Geobacter sp., and methanogens in response to biostimulation. Traditionally, characterization of sediment samples has been used to investigate the microbial community response to biostimulation; however, collection of sediment samples is expensive and not conducive to deep aquifers or temporal studies. The results presented demonstrate that push-pull tests with passive MLS provide an inexpensive approach to determine the effect of biostimulation on contaminant concentrations, geochemical conditions, and the microbial community composition and function. PMID:18194316

  3. Multilevel Samplers to Assess Microbial Community Response to Biostimulation

    NASA Astrophysics Data System (ADS)

    Baldwin, B. R.; McKinley, J. P.; Peacock, A. D.; Park, M.; Ogles, D.; Istok, J. D.; Resch, C. T.; White, D. C.

    2006-05-01

    Passive multilevel samplers (MLS) containing a solid matrix for microbial colonization were used in conjunction with a push-pull biostimulation experiment designed to promote biological U(VI) and Tc(VII) reduction. MLS were deployed at 24 elevations in the injection well and two down gradient wells to investigate the spatial variability in microbial community composition and growth prior to and following biostimulation. The microbial community was characterized by real-time PCR (Q-PCR) quantification of eubacteria, NO3- reducing bacteria (nirS and nirK), δ-proteobacteria, Geobacter sp., and methanogens (mcrA). Pretest cell densities were low overall but varied substantially with significantly greater eubacterial populations detected at circumneutral pH (T-test, α=0.05) suggesting carbon substrate and low pH limitation of microbial activity. Although pretest cell densities were low, denitrifying bacteria were dominant members of the microbial community. Biostimulation with an ethanol amended groundwater resulted in concurrent NO3- and Tc(VII) reduction followed by U(VI) reduction. Q-PCR analysis of MLS revealed significant (1-2 orders of magnitude, T-test, α=0.05) increases in cell densities of eubacteria, denitrifiers, δ- proteobacteria, Geobacter sp., and methanogens in response to biostimulation. Traditionally characterization of sediment samples has been used to investigate the microbial community response to biostimulation, however, collection of sediment samples is expensive and not conducive to deep aquifers or temporal studies. The results presented demonstrate that push-pull tests with passive MLS provide an inexpensive approach to determine the effect of biostimulation on contaminant concentrations, geochemical conditions, and the microbial community composition and function.

  4. NASA/JPL hydrothermal vent bio-sampler

    NASA Astrophysics Data System (ADS)

    Jonsson, J.; Behar, A.; Bruckner, J.; Matthews, J.

    pagestyle empty begin document On the bottom of the oceans with volcanic activity present hydrothermal vents can be found which spew out mineral rich superheated water from the porous seafloor crust Some of these vents are situated several thousands of meters below the surface where the sunlight never reaches Yet life thrives here on the minerals and chemical compounds that the vent water brings up with it This chemosynthetic microbial community forms the basis of some of the most interesting ecosystems on our planet and could possibly also be found on other water rich planets and moons in the solar system Perhaps under the icy surface of the moon Europa there exist hydrothermal vents with such biota thriving independently of the solar energy The Hydrothermal Vent Bio-sampler HVB is a system which will be used to collect pristine samples of the water emanating from hydrothermal vents An array of temperature and flow sensors will monitor the sampling conditions This will allow for the samples to be collected from defined locations within the plume and the diversity and distribution of the chemosynthetic communities that might live there can be accurately described The samples will have to be taken without any contamination from the surrounding water thus the pristine requirement Monitoring the flow will assure that enough water has been sampled to account for the low biomass of these environments The system will be using a series of filters down to 0 2 mu m in pore size and the samples can be directly collected from the system for both culture-

  5. Modification and calibration of a passive air sampler for monitoring vapor and particulate phase brominated flame retardants in indoor air: application to car interiors.

    PubMed

    Abdallah, Mohamed Abou-Elwafa; Harrad, Stuart

    2010-04-15

    A passive air sampler was modified to monitor both vapor and particulate phase brominated flame retardants (BFRs) in indoor air using polyurethane foam disks and glass fiber filters (GFF). Significant correlation (p < 0.01) was observed between passive (ng day(-1)) and active sampler (ng m(-3)) derived BFR concentrations in an office microenvironment (r = 0.94 and 0.89 for vapor and particulate phase BFRs, respectively). A calibration experiment was performed where concentrations of target BFRs were obtained for an office using a low volume active sampler operated over a 50 day period alongside passive samplers. The passive uptake rates of each studied BFR ranged between (0.558-1.509 ng day(-1)) and (0.448-0.579 ng day(-1)) for vapor and particulate phases, respectively. The passive entrapment of particles by the GFF was investigated using environmental scanning electron microscopy which revealed gravitational deposition of particles as the main mechanism involved. The developed sampler was applied to monitor BFR concentrations in 21 cars. Average concentrations of SigmaHBCDs, TBBP-A, and Sigmatetra-deca BDEs were 400, 3, and 2200 pg m(-3) in cabins and 400, 1, and 1600 pg m(-3) in trunks. No significant differences (p < 0.05) were observed between levels of SigmaHBCDs and Sigmatrito hexa- BDEs in cabins and trunks. However, TBBP-A, BDE-209, and SigmaPBDEs concentrations were significantly higher in vehicle cabins. PMID:20230020

  6. Evaluation of IOM personal sampler at different flow rates.

    PubMed

    Zhou, Yue; Cheng, Yung-Sung

    2010-02-01

    The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates. PMID:19953412

  7. A collaborative European study of personal inhalable aerosol sampler performance.

    PubMed

    Kenny, L C; Aitken, R; Chalmers, C; Fabriès, J F; Gonzalez-Fernandez, E; Kromhout, H; Lidén, G; Mark, D; Riediger, G; Prodi, V

    1997-04-01

    Following the adoption of new international sampling conventions for inhalable, thoracic and respirable aerosol fractions, a working group of Comité Européen de Normalisation (CEN) drafted a standard for the performance of workplace aerosol sampling instruments. The present study was set up to verify the experimental, statistical and mathematical procedures recommended in the draft performance standard and to check that they could be applied to inhalable aerosol samplers. This was achieved by applying the tests to eight types of personal inhalable aerosol sampler commonly used for workplace monitoring throughout Europe. The study led to recommendations for revising the CEN draft standard, in order to simplify the tests and reduce their cost. However, some further work will be needed to develop simpler test facilities and methods. Several of the samplers tested were found to perform adequately with respect to the inhalable sampling convention, at least over a limited range of typical workplace conditions. In general the samplers were found to perform best in low external wind speeds, which are the test conditions thought to be closest to those normally found in indoor workplaces. The practical implementation of the CEN aerosol sampling conventions requires decisions on which sampling instruments to use, estimation of the likely impact that changing sampling methods could have on apparent exposures, and adjustment where necessary of exposure limit values. The sampler performance data obtained in this project were affected by large experimental errors, but are nevertheless a useful input to decisions on how to incorporate the CEN inhalable sampling convention into regulation, guidance and occupational hygiene practice. PMID:9155236

  8. Analytical sensitivity of air samplers based on uniform point-source exposure to airborne Porcine reproductive and respiratory syndrome virus and swine influenza virus

    PubMed Central

    Hermann, Joseph R.; Zimmerman, Jeffrey J.

    2008-01-01

    Research and surveillance activities involving airborne pathogens rely on the capture and enumeration of pathogens suspended in aerosols. The objective of this study was to estimate the analytical sensitivity (detection threshold) of each of 4 air samplers for Porcine reproductive and respiratory syndrome virus (PRRSV) and swine influenza virus (SIV). In a 5-min sampling period under controlled conditions, the analytical sensitivity of the AGI-30 (Ace Glass, Vineland, New Jersey, USA), AGI-4 (Ace Glass), SKC BioSampler (SKC, Eighty Four, Pennsylvania, USA), and Midwest Micro-Tek sampler (Midwest Micro-Tek, Brookings, South Dakota, USA) was calculated at 1 × 101.1, 1 × 101.3, 1 × 101.1, and 1 × 101.2 median tissue culture infectious dose (TCID50) equivalents for PRRSV and 1 × 101.4, 1 × 101.1, 1 × 101.6, and 1 × 101.2 TCID50 equivalents for SIV [per 60 L (5-min sampling period)]. Despite marked differences in sampler design, no statistically significant difference in analytical sensitivity was detected between the samplers for collection of artificially produced aerosols containing cell-culture-propagated PRRSV or SIV. PMID:19086377

  9. An assessment of the variability in performance of wet atmospheric deposition samplers

    USGS Publications Warehouse

    Graham, R.C.; Robertson, J.K.; Obal, John

    1987-01-01

    The variability in performance of two brands of wet/dry atmospheric deposition samplers were compared for 1 year at a sincle site. A total of nine samplers were used. Samples were collected weekly and analyzed for pH, specific conductance, common chemical constituents, and sample volume. Additionally, data on the duration of each sampler opening were recorded using a microdatalogger. These data disprove the common perception that samplers remain open throughout a precipitation event. The sensitivity of sampler sensors within the range tested did not have a defineable impact on sample collection. The nonnormal distribution within the data set necessitated application of the nonparametric Friedman Test to assess comparability of sample chemical composition and volume between and within sampler brands. Statistically significant differences existed for most comparisons, however the test did not permit quantification of their magnitudes. Differences in analyte concentrations between samplers were small. (USGS)

  10. Considerations for sampling inorganic constituents in ground water using diffusion samplers

    USGS Publications Warehouse

    Vroblesky, D.A.; Petkewich, M.D.; Campbell, T.R.

    2002-01-01

    Data indicate that nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water from wells that closely correspond to concentrations obtained by low-flow sampling. Conservative solutes, such as chloride, can be sampled by filling the diffusion samplers with oxygenated water. The samplers should be filled with anaerobic water for sampling redoxsensitive solutes. Oxidation of iron within the samplers, either by using aerobic fill water or by in-well oxygenation events, can lead to erroneous iron concentrations. Lithologic and chemical heterogeneity and sampler placement depth can lead to differences between concentrations from diffusion samples and low-flow samples because of mixing during pumping. A disadvantage of regenerated cellulose dialysis samplers is that they can begin to biodegrade within the two weeks of deployment. Nylon-screen samplers buried beneath streambed sediment along the unnamed tributary in a discharge zone of arseniccontaminated ground water were useful in locating the specific discharge zone.

  11. Evaluating the PAS-SIM model using a passive air sampler calibration study for pesticides.

    PubMed

    Restrepo, Andrés Ramírez; Hayward, Stephen J; Armitage, James M; Wania, Frank

    2015-07-01

    The main objective of this study was to evaluate the performance of a model for simulating the uptake of various pesticides on passive air samplers (PAS). From 2006-2007 a series of PAS using XAD-resin were deployed at Egbert, a rural agricultural site in southern Ontario, Canada, to measure the uptake of pesticides for time periods ranging from two months to one year. A continuous increase in sequestered amounts was observed for most pesticides, except for trifluralin and pendimethalin, which could conceivably be subject to substantial degradation inside the sampler. Continuous low-volume active air samples taken during the same period, along with data on weather conditions, allowed for the simulation of the uptake of the pesticides using the model (PAS-SIM). The modelled accumulation of pesticides on the PAS over the deployment period was in good agreement with the experimental data in most cases (i.e., within a factor of two) providing insight into the uptake kinetics of this type of sampler in the field. Passive sampling rates (PSR, m(3) d(-1)) were determined from the empirical data generated for this study using three different methods and compared with the PSRs generated by the model. Overall, the PAS-SIM model, which is capable of accounting for the influence of temperature and wind variations on PSRs, provided reasonable results that range between the three empirical approaches employed and well-established literature values. Further evaluation and application of the PAS-SIM model to explore the potential spatial and temporal variability in PAS uptake kinetics is warranted, particularly for established monitoring sites where detailed meteorological data are more likely to be available. PMID:26083201

  12. Study of Nox Levels At The Castellon Area (spain) By Means of Passive Samplers

    NASA Astrophysics Data System (ADS)

    Delgado, J. M.; Esteve, V.

    Nitrogen oxides are emitted by mobile sources like traffic, heating engines and indus- tries. In the case of La Plana de Castellon area, the cities, the industrial area called El Serrallo (with its oil refinery and power plant), the tile factories and the main roads (A7-E15 and N-340), all they are the main pollutant focus of NOx. Those pollutants are precursors of tropospheric ozone formation. The aim of this work is the study of nitrogen oxides levels in La Plana de Castellon area, by means of passive samplers and stand relationships between NOx levels and ozone levels both measured with pas- sive samplers. The measurement campaign is made during summer, the higher pho- tochemical activity period (from May to September) in order to obtain the necessary data of NOx levels to make the relationship with measured ozone levels. Measuring campaing has been divided into sampling periods of one week. Twelve samples are collected each sampling period to cover an interest area of 1400 Km2, Two of these samples are laboratory blanks, four are situated at reference points (beside an auto- matic NOx sampler), one is situated at A7-E15 expressway, other at the main road N-340 and another one in a hard traffic road. The other three are placed in the main cities (Castellon and Benicassim). We employ Radielloo samplers developed by Dr. Cocheo at Fondazione Salvatore Maugeri. Samples located far from the main roads, at countryside show the lowest levels of NOx, lower than 10 ppb. Samples located at Castellon city show a difference between downtown and boundaries of about 33% higher at downtown, raising from 11 ppb to 14,5 ppb of NOx. The highest levels of NOx are measured at roads and their surroundings with medium levels of 14,3 ppb of NOx. Moreover, the sample located close to the expressway raises its level until 18 ppb of NOx, 53,4% higher than the media of all the samples measured. We would like to thank Dr. M. Wolfson(Harvard University), Dr. Carlos Felis (Conselleria de

  13. A Gibbs sampler for motif detection in phylogenetically close sequences

    NASA Astrophysics Data System (ADS)

    Siddharthan, Rahul; van Nimwegen, Erik; Siggia, Eric

    2004-03-01

    Genes are regulated by transcription factors that bind to DNA upstream of genes and recognize short conserved ``motifs'' in a random intergenic ``background''. Motif-finders such as the Gibbs sampler compare the probability of these short sequences being represented by ``weight matrices'' to the probability of their arising from the background ``null model'', and explore this space (analogous to a free-energy landscape). But closely related species may show conservation not because of functional sites but simply because they have not had sufficient time to diverge, so conventional methods will fail. We introduce a new Gibbs sampler algorithm that accounts for common ancestry when searching for motifs, while requiring minimal ``prior'' assumptions on the number and types of motifs, assessing the significance of detected motifs by ``tracking'' clusters that stay together. We apply this scheme to motif detection in sporulation-cycle genes in the yeast S. cerevisiae, using recent sequences of other closely-related Saccharomyces species.

  14. Comparison. US P-61 and Delft sediment samplers

    USGS Publications Warehouse

    Beverage, Joseph P.; Williams, David T.

    1990-01-01

    The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).

  15. Structure and conformational analysis of 5,11-dibenzyldibenzo[b,f][1,5]diazocine-6,12-dione. A novel approach for new chemosensitizers

    NASA Astrophysics Data System (ADS)

    Nonnenmacher, E.; Brouant, P.; Mrozek, A.; Karolak-Wojciechowska, J.; Barbe, J.

    2000-04-01

    On the basis of structural similarities between various calcium channel antagonists (Verapamil or Diltiazem) a novel series of derivatives belonging to the dibenzodiazocinedione family were designed and synthesised to obtain drugs able to revert multidrug resistance (MDR). X-ray structure studies and conformational analysis of 5,11-dibenzyldibenzo[b,f][1,5]diazocine-6,12-dione were performed. Molecular modelling results have shown that observed reversal activity of this new derivative could refer to a thermodynamically limited concentration in a peculiar (extended) conformation.

  16. A Method of Estimating FRM PM10 Sampler Performance Characteristics Using Particle Size Analysis and Collocated TSP and PM10 Samplers

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In the US, regional air quality compliance with national ambient air quality standards (NAAQS) for PM10 is based on concentration measurements taken by federal reference method (FRM) PM10 samplers. The EPA specifies the performance characteristics of the FRM PM10 sampler by defining ranges for the p...

  17. Filter and electrostatic samplers for semivolatile aerosols: physical artifacts.

    PubMed

    Volckens, John; Leith, David

    2002-11-01

    Adsorptive and evaporative artifacts often bias measurements of semivolatile aerosols. Adsorption occurs when the sampling method disrupts the gas-particle partitioning equilibrium. Evaporation occurs because concentrations of semivolatiles are rarely constant over time. Filtration is subject to both adsorptive and evaporative artifacts. By comparison, electrostatic precipitation reduces these artifacts by minimizing the surface area of collected particles without substantially disrupting the gas-particle equilibrium. The extent of these artifacts was determined for filter samplers and electrostatic precipitator samplers for semivolatile alkane aerosols in the laboratory. Adsorption of gas-phase semivolatiles was lower in electrostatic precipitators by factors of 5-100 compared to the filter method. Particle evaporation from the electrostatic sampler was 2.3 times lower than that from TFE-coated glass-fiber filters. Use of a backup filter to correct for compound-specific adsorption artifacts can introduce positive or negative errors to the measured particle-phase concentration due to competition among the adsorbates for available adsorption sites. Adsorption of evaporated particles from the front filter onto the backup filter increased the measured evaporative artifact by a factor of 1.5-2. PMID:12433172

  18. A sampler for coring sediments in rivers and estuaries

    USGS Publications Warehouse

    Prych, Edmund A.; Hubbell, D.W.

    1966-01-01

    A portable sampler developed to core submerged unconsolidated sediments collects cores that are 180 cm long and 4.75cm in diameter. The sampler is used from a 12-m boat in water depths up to 20 m and in flow velocities up to 1.5m per second to sample river and estuarine deposits ranging from silty clay to medium sand. Even in sand that cannot be penetrated with conventional corers, the sampler achieves easy penetration through the combined application of vibration, suction, and axial force. A piston in the core barrel creates suction, and the suspension system is arranged so that tension on the support cable produces both a downward force on the core barrel and a lateral support against overturning. Samples are usually retained because of slight compaction in the driving head; as a precaution, however, the bottom of the core barrel is covered by a plate that closes after the barrel is withdrawn from the bed. Tests show that sample-retainers placed within the driving head restrict penetration and limit core lengths. Stratification within cores is disrupted little as a result of the sampling process.

  19. A carbon monoxide passive sampler: Research and development needs

    SciTech Connect

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  20. Modeling uptake of hydrophobic organic contaminants into polyethylene passive samplers.

    PubMed

    Thompson, Jay M; Hsieh, Ching-Hong; Luthy, Richard G

    2015-02-17

    Single-phase passive samplers are gaining acceptance as a method to measure hydrophobic organic contaminant (HOC) concentration in water. Although the relationship between the HOC concentration in water and passive sampler is linear at equilibrium, mass transfer models are needed for nonequilibrium conditions. We report measurements of organochlorine pesticide diffusion and partition coefficients with respect to polyethylene (PE), and present a Fickian approach to modeling HOC uptake by PE in aqueous systems. The model is an analytic solution to Fick's second law applied through an aqueous diffusive boundary layer and a polyethylene layer. Comparisons of the model with existing methods indicate agreement at appropriate boundary conditions. Laboratory release experiments on the organochlorine pesticides DDT, DDE, DDD, and chlordane in well-mixed slurries support the model's applicability to aqueous systems. In general, the advantage of the model is its application in the cases of well-agitated systems, low values of polyethylene-water partioning coefficients, thick polyethylene relative to the boundary layer thickness, and/or short exposure times. Another significant advantage is the ability to estimate, or at least bound, the needed exposure time to reach a desired CPE without empirical model inputs. A further finding of this work is that polyethylene diffusivity does not vary by transport direction through the sampler thickness. PMID:25607420

  1. A new sampler design for measuring sedimentation in streams

    USGS Publications Warehouse

    Hedrick, Lara B.; Welsh, S.A.; Hedrick, J.D.

    2005-01-01

    Sedimentation alters aquatic habitats and negatively affects fish and invertebrate communities but is difficult to quantify. To monitor bed load sedimentation, we designed a sampler with a 10.16-cm polyvinyl chloride coupling and removable sediment trap. We conducted a trial study of our samplers in riffle and pool habitats upstream and downstream of highway construction on a first-order Appalachian stream. Sediment samples were collected over three 6-week intervals, dried, and separated into five size-classes by means of nested sieves (U.S. standard sieve numbers 4, 8, 14, and 20). Downstream sediment accumulated in size-classes 1 and 2, and the total amount accumulated was significantly greater during all three sampling periods. Size-classes 3 and 4 had significantly greater amounts of sediment for the first two sampling periods at the downstream site. Differences between upstream and downstream sites narrowed during the 5-month sampling period. This probably reflects changes in site conditions, including the addition of more effective sediment control measures after the first 6-week period of the study. The sediment sampler design allowed for long-term placement of traps without continual disturbance of the streambed and was successful at providing repeat measures of sediment at paired sites. ?? Copyright by the American Fisheries Society 2005.

  2. Hydrothermal Vent Sampler: Does Life Exist in High Temperature Environments?

    NASA Technical Reports Server (NTRS)

    Rivadeneyra, Cesar R.

    2005-01-01

    The main purpose of this research is to search for the existence of biomass under extreme temperature and pressure conditions to determine the upper bounds of environments on which life can exist. Vents are, simply put, underwater volcano openings located at the bottom of the sea. The conditions at these locations are considerably extreme with pressures of up to 10,000 psi, and enormous temperature gradients. The temperature of the water near these vents is around 400 C, while that of the surrounding water is about 3 C. The extremity of these conditions makes it hard to estimate the existence of life in those environments. I n order to find whether such existence happens, we need to search for biomass inside these vents. The vent sampler is a device that has the purpose of safely and accurately collecting this biomass for examination. This sampler is constituted of a Series of filters of the order of 100-0.2 microns in size. Since this is a 3-year project, it has not concluded yet; however, during the time I contributed to this project, I worked with the mechanical design of this sampler device including the selection, assembly, and testing of the various subsystems and the design and construction of the electronics enclosure.

  3. Kinetically Blocked Stable 5,6:12,13-Dibenzozethrene: A Laterally π-Extended Zethrene with Enhanced Diradical Character.

    PubMed

    Yadav, Priya; Das, Soumyajit; Phan, Hoa; Herng, Tun Seng; Ding, Jun; Wu, Jishan

    2016-06-17

    Although the ground-state and physical properties of zethrene and recently invented 1,2:8,9-dibenzozethrene have been well studied, the other dibenzozethrene isomer, i.e., 5,6:12,13-dibenzozethrene, remained unexplored. A short synthetic route to a kinetically blocked stable 5,6:12,13-dibenzozethrene derivative 5 is presented. The ground state is found to be open-shell singlet experimentally, and the theoretical y0 was enhanced to 0.414, which corroborates nicely with the experimental and theoretical singlet-triplet energy gap. PMID:27227758

  4. Birds Make Learning Easy. Science Sampler

    ERIC Educational Resources Information Center

    Parott, Joanne

    2004-01-01

    Through this middle school curriculum, students observe bird feeders outside their classrooms, learn to identify birds that visit, and use a simple protocol for counting the birds and collecting other data before sending it to Cornell scientists via the Internet. The activities within the curriculum are inquiry-based and interdisciplinary. This…

  5. Development of the Releasable Asbestos Field Sampler

    EPA Science Inventory

    A risk assessment for intermittent, low-level exposure to asbestos requires personal breathing concentration data. Currently, activity-based sampling (ABS) is the preferred approach to measurement of a person’s inhalation exposure; i.e., asbestos structures per cubic centimeter ...

  6. Auto-Gopher: A Wireline Deep Sampler Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Ressa, Aaron; Jae Lee, Hyeong; Bar-Cohen, Yoseph; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L.; Beegle, Luther; Bao, Xiaoqi

    2013-01-01

    The ability to penetrate subsurfaces and perform sample acquisition at depth of meters may be critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of enabling acquisition of samples from depths of several meters where if used on Mars would be beyond the oxidized and sterilized zone. For this purpose, we developed a rotary-hammering coring drill, called Auto-Gopher, which employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor that rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that can be fed into and retrieved from the drilled hole using a winch and a cable. It includes an inchworm anchoring mechanism allowing the drill advancement and weight on bit control without twisting the reeling and power cables. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The design and fabrication of this device were presented in previous publications. This paper presents the results of laboratory and field tests and lessons learned from this development.

  7. Field validation of polyethylene passive air samplers for parent and alkylated PAHs in Alexandria, Egypt.

    PubMed

    Khairy, Mohammed A; Lohmann, Rainer

    2012-04-01

    Polyethylene samplers (PEs) were deployed at 11 locations in Alexandria, Egypt during summer and winter to test and characterize them as passive samplers for concentrations, sources, and seasonal variations of atmospheric concentrations of polycyclic aromatic hydrocarbons (PAHs). PE-air equilibrium was attained faster for a wider range of PAHs during the winter season possibly due to increased wind speeds. Calculated PE-air partitioning constants, K(PE-A), in our study [Log K(PE-A) = 0.9426 × Log K(OA) - 0.022 (n = 12, R(2) = 0.99, Std error = 0.053)] agreed with literature values within <46%. For parent (except naphthalene), mono- and dialkylated PAHs, active sampling based concentrations of PAHs were within an average factor of 1.4 (1.0-5.6) compared to the PE based values. For C(3-4) alkylated PAHs, K(PE-A) values were lower than predicted, on average by ~0.8 log units per carbon in the alkylation. Enthalpies of vaporization (ΔH(vap)) accurately corrected K(PE-A)s for temperature differences between winter and summer sampling. PAH profiles were dominated by naphthalene, phenanthrene, and alkylated phenanthrenes. Calculated diagnostic ratios indicated that PAHs originated mainly from vehicle emissions. PMID:22397460

  8. Dioxin analysis in water by using a passive sampler and CALUX bioassay.

    PubMed

    Addeck, Amr; Croes, Kim; Van Langenhove, Kersten; Denison, Michael; Elskens, Marc; Baeyens, Willy

    2012-01-15

    Passive sampling of organic pollutants is a new trend in environmental monitoring and analysis. Passive samplers are being developed to overcome the drawbacks of the conventional snapshot sampling approach. The ceramic toximeter is a promising passive sampler for monitoring dioxin-contaminated surface and ground waters. It consists of an alumina cylinder lined with a thin coating of titania and a pore diameter of 0.05 μm. The cylinder serves as a diffusion barrier limiting the analyte transport to molecular diffusion only, as well as a container for a selective trapping material of a high capacity and affinity towards the chemical(s) of concern. The cylinder is closed from both sides with PTFE caps. The ceramic toximeter was filled with activated carbon as the trapping material and has been tested in vitro for the sampling of dioxin-contaminated water. In addition, the utilization of the CALUX bioassay technique for analyzing the trapped dioxin has greatly reduced the time and costs for dioxin scanning in aqueous media. Exposure times varied between 1 and 7 days in a solution of 1.35 ng-TCDDL(-1) (TCDD is 2,3,7,8-tetrachlorodibenzodioxin). The mean effective molecular diffusion coefficient of TCDD in the toximeter amounts to 11.9×10(-6)m(2)d(-1) while the minimum concentration detectable in an aquatic system after 30 days of exposure amounts to 0.89 pg-TCDDL(-1). PMID:22265472

  9. Determination of phenolic compounds in air by using cyclodextrin-silica hybrid microporous composite samplers.

    PubMed

    Mauri-Aucejo, Adela R; Ponce-Català, Patricia; Belenguer-Sapiña, Carolina; Amorós, Pedro

    2015-03-01

    An analytical method for the determination of phenolic compounds in air samples based on the use of cyclodextrin-silica hybrid microporous composite samplers is proposed. The method allows the determination of phenol, guaiacol, cresol isomers, eugenol, 4-ethylphenol and 4-ethylguaiacol in workplaces according to the Norm UNE-EN 1076:2009 for active sampling. Therefore, the proposed method offers an alternative for the assessment of the occupational exposure to phenol and cresol isomers. The detection limits of the proposed method are lower than those for the NIOSH Method 2546. Storage time of samples almost reaches 44 days. Recovery values for phenol, guaiacol, o-cresol, m-cresol, p-cresol, 4-ethylguaiacol, eugenol and 4-ethylphenol are 109%, 99%, 102%, 94%, 94%, 91%, 95% and 102%, respectively with a coefficient of variation below 6%. The method has been applied to the assessment of exposure in different areas of a farm and regarding the quantification of these compounds in the vapors generated by burning incense sticks and an essential oil marketed as air fresheners. The acquired results are comparable with those provided from a reference method for a 95% of confidence level. The possible use of these samplers for the sampling of other toxic compounds such as phthalates is evaluated by qualitative analysis of extracts from incense sticks and essential oil samples. PMID:25618708

  10. Sizing alpha emitting particles of aged plutonium on personal air sampler filters using CR-39 autoradiography.

    PubMed

    Richardson, R B; Hegyi, G; Starling, S C

    2003-01-01

    Methods have been developed to assess the size distribution of alpha emitting particles of reactor fuel of known composition captured on air sampler filters. The sizes of uranium oxide and plutonium oxide particles were determined using a system based on CR-39 solid-state nuclear track detectors. The CR-39 plastic was exposed to the deposited particles across a 400 microm airgap. The exposed CR-39 was chemically etched to reveal clusters of tracks radially dispersed from central points. The number and location of the tracks were determined using an optical microscope with an XY motorised table and image analysis software. The sample mounting arrangement allowed individual particles to be simultaneously viewed with their respective track cluster. The predicted diameters correlated with the actual particle diameters, as measured using the optical microscope. The efficacy of the technique was demonstrated with particles of natural uranium oxide (natUO2) of known size, ranging from 4 to 150 microm in diameter. Two personal air sampler (PAS) filters contaminated with actinide particles were placed against CR-39 and estimated to have size distributions of 0.8 and 1.0 microm activity median aerodynamic diameter (AMAD). PMID:14526944

  11. Summary report on the design of the retained gas sampler system (retained gas sampler, extruder and extractor)

    SciTech Connect

    Wootan, D.W.; Bolden, R.C.; Bridges, A.E.; Cannon, N.S.; Chastain, S.A.; Hey, B.E.; Knight, R.C.; Linschooten, C.G.; Pitner, A.L.; Webb, B.J.

    1994-09-29

    This document summarizes work performs in Fiscal Year 1994 to develop the three main components of Retained Gas Sampler System (RGSS). These primary components are the Retained Gas Sampler (RGS), the Retained Gas Extruder (RGE), and the Retained Gas Extractor (RGEx). The RGS is based on the Westinghouse Hanford Company (WHC) Universal Sampler design, and includes modifications to reduce gas leakage. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. Significant progress has been made in developing the RGSS. The RGSS is being developed by WHC to extract a representative waste sample from a Flammable Gas Watch List Tanks and to measure both the amount and composition of free and {open_quotes}bound{close_quotes} gases. Sudden releases of flammable gas mixtures are a safety concern for normal waste storage operations and eventual waste retrieval. Flow visualization testing was used to identify important fluid dynamic issues related to the sampling process. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. The safety analysis for the RGSS is being performed by Los Alamos National Laboratory and is more than sixty percent (60%) complete.

  12. 40 CFR 721.6100 - Phosphoric acid, C6-12-alkyl esters, compounds with 2-(dibutylamino) ethanol.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., compounds with 2-(dibutylamino) ethanol. 721.6100 Section 721.6100 Protection of Environment ENVIRONMENTAL..., compounds with 2-(dibutylamino) ethanol. (a) Chemical substances and significant new uses subject to reporting. (1) The chemical substances identified as phosphoric acid, C6-12-alkyl esters, compounds with...

  13. 40 CFR 721.6100 - Phosphoric acid, C6-12-alkyl esters, compounds with 2-(dibutylamino) ethanol.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., compounds with 2-(dibutylamino) ethanol. 721.6100 Section 721.6100 Protection of Environment ENVIRONMENTAL..., compounds with 2-(dibutylamino) ethanol. (a) Chemical substances and significant new uses subject to reporting. (1) The chemical substances identified as phosphoric acid, C6-12-alkyl esters, compounds with...

  14. 40 CFR 721.6100 - Phosphoric acid, C6-12-alkyl esters, compounds with 2-(dibutylamino) ethanol.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., compounds with 2-(dibutylamino) ethanol. 721.6100 Section 721.6100 Protection of Environment ENVIRONMENTAL..., compounds with 2-(dibutylamino) ethanol. (a) Chemical substances and significant new uses subject to reporting. (1) The chemical substances identified as phosphoric acid, C6-12-alkyl esters, compounds with...

  15. 40 CFR 721.6100 - Phosphoric acid, C6-12-alkyl esters, compounds with 2-(dibutylamino) ethanol.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., compounds with 2-(dibutylamino) ethanol. 721.6100 Section 721.6100 Protection of Environment ENVIRONMENTAL..., compounds with 2-(dibutylamino) ethanol. (a) Chemical substances and significant new uses subject to reporting. (1) The chemical substances identified as phosphoric acid, C6-12-alkyl esters, compounds with...

  16. 40 CFR 721.6100 - Phosphoric acid, C6-12-alkyl esters, compounds with 2-(dibutylamino) ethanol.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., compounds with 2-(dibutylamino) ethanol. 721.6100 Section 721.6100 Protection of Environment ENVIRONMENTAL..., compounds with 2-(dibutylamino) ethanol. (a) Chemical substances and significant new uses subject to reporting. (1) The chemical substances identified as phosphoric acid, C6-12-alkyl esters, compounds with...

  17. Immunogenicity and safety of a trivalent inactivated 2010-2011 influenza vaccine in Taiwan infants aged 6-12 months.

    PubMed

    Hwang, Kao-Pin; Hsu, Yu-Lung; Hsieh, Tsung-Hsueh; Lin, Hsiao-Chuan; Yen, Ting-Yu; Wei, Hsiu-Mei; Lin, Hung-Chih; Chen, An-Chyi; Chow, Julie Chi; Huang, Li-Min

    2014-05-01

    This prospective study aimed to investigate the immune responses and safety of an influenza vaccine in vaccine-naïve infants aged 6-12 months, and was conducted from November 2010 to May 2011. Fifty-nine infants aged 6-12 months received two doses of trivalent inactivated influenza vaccine 4 weeks apart. Hemagglutination inhibition titers were measured 4 weeks after the two doses of study vaccine. Based on the assumption that a hemagglutination inhibition titer of 1:40 or greater against the antigen would be protective in adults, two doses of the study vaccine generated a protective immune response of 63.2% against influenza A(H1N1), 82.5% against influenza A(H3N2) and 38.6% against influenza B viruses in infants aged 6-12 months. The geometric mean fold rises against influenza type A and B viruses also met the European Medicines Agency criteria for flu vaccines. The solicited events within 7 days after vaccination were mild in intensity. No deaths or adverse events such as optic neuritis, cranial neuropathy, and brachial neuropathy or Guillain-Barre syndrome were reported. Two doses of inactivated influenza vaccine were well tolerated and induced a protective immune response against influenza in infants aged 6-12 months. PMID:24625341

  18. Development of an ambient air sampler that satisfies RF plant monitoring requirements

    SciTech Connect

    Nininger, R.C.; Pauley, B.J.

    1993-05-01

    EG&G Rocky Flats Plant (RFP) is developing a new ambient air particulate sampler to replace units that have been in service for about twenty years. The new sampler is required to operate at a flow rate approximately twice that of the existing samplers and admit particles as large as 70 micrometers aerodynamic diameter. The sampler provides two size fractions with separation at 10 micrometers. using a single stage impactor designed at RFP and carrying a Department of Energy (DOE) patent. The sampler is modular for easy servicing in the field and its operation can be checked via radiotelemetry. The sampler, designed to meet Environmental Protection Agency (EPA) requirements for PM-10 sampling, is currently being characterized in EPA`s laboratories at Research Triangle Park, North Carolina.

  19. Development of an ambient air sampler that satisfies RF plant monitoring requirements

    SciTech Connect

    Nininger, R.C.; Pauley, B.J.

    1993-01-01

    EG G Rocky Flats Plant (RFP) is developing a new ambient air particulate sampler to replace units that have been in service for about twenty years. The new sampler is required to operate at a flow rate approximately twice that of the existing samplers and admit particles as large as 70 micrometers aerodynamic diameter. The sampler provides two size fractions with separation at 10 micrometers. using a single stage impactor designed at RFP and carrying a Department of Energy (DOE) patent. The sampler is modular for easy servicing in the field and its operation can be checked via radiotelemetry. The sampler, designed to meet Environmental Protection Agency (EPA) requirements for PM-10 sampling, is currently being characterized in EPA's laboratories at Research Triangle Park, North Carolina.

  20. Acid Precipitation Learning Materials: Science, Environmental and Social Studies, Grades 6-12.

    ERIC Educational Resources Information Center

    Hessler, Edward W.

    The major environmental problem of acid precipition is addressed through a series of activities contained in this guide for teachers of grades 6 through 12. Exercises are provided to help students learn science inquiry skills, facts, and concepts while focusing on the acid rain situation. Activities are organized by content areas. These include:…

  1. A minimally invasive micro sampler for quantitative sampling with an ultrahigh-aspect-ratio microneedle and a PDMS actuator.

    PubMed

    Liu, Long; Wang, Yan; Yao, Jinyuan; Yang, Cuijun; Ding, Guifu

    2016-08-01

    This study describes a novel micro sampler consisting of an ultrahigh-aspect-ratio microneedle and a PDMS actuator. The microneedle was fabricated by a new method which introduced reshaped photoresist technology to form a flow channel inside. The microneedle includes two parts: shaft and pedestal. In this study, the shaft length is 1500 μm with a 45° taper angle on the tip and pedestal is 1000 μm. Besides, the shaft and pedestal are connected by an arc connection structure with a length of 600 μm. The microneedles have sufficient mechanical strength to insert into skin with a wide safety margin which was proved by mechanics tests. Moreover, a PDMS actuator with a chamber inside was designed and fabricated in this study. The chamber, acting as a reservoir in sampling process as well as providing power, was optimized by finite element analysis (FEA) to decrease dead volume and improve sampling precision. The micro sampler just needs finger press to activate the sampling process as well as used for quantitative micro injection to some extent. And a volume of 31.5 ± 0.8 μl blood was successfully sampled from the ear artery of a rabbit. This micro sampler is suitable for micro sampling for diagnose or therapy in biomedical field. PMID:27372944

  2. Assessment of field-related influences on polychlorinated biphenyl exposures and sorbent amendment using polychaete bioassays and passive sampler measurements

    USGS Publications Warehouse

    Janssen, E.M.; Oen, A.M.; Luoma, S.N.; Luthy, R.G.

    2011-01-01

    Field-related influences on polychlorinated biphenyl (PCB) exposure were evaluated by employing caged deposit-feeders, Neanthes arenaceodentata, along with polyoxymethylene (POM) samplers using parallel in situ and ex situ bioassays with homogenized untreated or activated carbon (AC) amended sediment. The AC amendment achieved a remedial efficiency in reducing bioaccumulation by 90% in the laboratory and by 44% in the field transplants. In situ measurements showed that PCB uptake by POM samplers was greater for POM placed in the surface sediment compared with the underlying AC amendment, suggesting that tidal exchange of surrounding material with similar PCB availability as untreated sediment was redeposited in the cages. Polychlorinated biphenyls bioaccumulation with caged polychaetes from untreated sediment was half as large under field conditions compared with laboratory conditions. A biodynamic model was used to confirm and quantify the different processes that could have influenced these results. Three factors appeared most influential in the bioassays: AC amendment significantly reduces bioavailability under laboratory and field conditions; sediment deposition within test cages in the field partially masks the remedial benefit of underlying AC-amended sediment; and deposit-feeders exhibit less PCB uptake from untreated sediment when feeding is reduced. Ex situ and in situ experiments inevitably show some differences that are associated with measurement methods and effects of the environment. Parallel ex situ and in situ bioassays, passive sampler measurements, and quantifying important processes with a model can tease apart these field influences. ?? 2010 SETAC.

  3. Validation of diffusive mini-samplers for aldehyde and VOC and its feasibility for measuring the exposure levels of elementary school children.

    PubMed

    Araki, Atsuko; Tsuboi, Tazuru; Kawai, Toshio; Bamai, Yu Ait; Takeda, Tomoya; Yoshioka, Eiji; Kishi, Reiko

    2012-02-01

    Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of

  4. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler.

    PubMed

    Madsen, A M; Sharma, A K

    2008-04-01

    For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field sampler for collection of fine particles has been described. The aim of this study was to investigate whether this sampler can be used for collection of high amounts of authentic bioaerosols that can subsequently be used for biological analysis. The investigation was carried out at a biofuel plant in a straw storage room and in a boiler room over two seasons. The sampled dust was quantified in terms of mass and characterized regarding microbial components and compared with dust sampled by Gravikon and GSP samplers. For the electrostatic field sampler, a prefilter was used to remove large objects. The prefilter was characterized for particle penetration and this testing indicated that the prefilter did not remove particles up to 10 mum, and therefore respirable dust was sampled by the electrostatic field sampler. Using the electrostatic field sampler in the straw storage and in the boiler room, 330 and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured by the electrostatic field sampler and 11.8 mg m(-3) when measured by the GSP inhalable dust sampler. The quantity (amount per mg dust) of total fungi, Aspergillus fumigatus, total bacteria

  5. Quartz Measurement in Coal Dust with High-Flow Rate Samplers: Laboratory Study

    PubMed Central

    LEE, TAEKHEE; LEE, EUN GYUNG; KIM, SEUNG WON; CHISHOLM, WILLIAM P.; KASHON, MICHAEL; HARPER, MARTIN

    2015-01-01

    A laboratory study was performed to measure quartz in coal dust using high-flow rate samplers (CIP10-R, GK2.69 cyclone, and FSP10 cyclone) and low-flow rate samplers [10-mm nylon and Higgins–Dewell type (BGI4L) cyclones] and to determine whether an increased mass collection from high-flow rate samplers would affect the subsequent quartz measurement by Fourier transform infrared (FTIR) and X-ray diffraction (XRD) analytical procedures. Two different sizes of coal dusts, mass median aerodynamic diameter 4.48 μm (Coal Dust A) and 2.33 μm (Coal Dust B), were aerosolized in a calm air chamber. The mass of coal dust collected by the samplers was measured gravimetrically, while the mass of quartz collected by the samplers was determined by FTIR (NIOSH Manual of Analytical Method 7603) and XRD (NIOSH Manual of Analytical Method 7500) after one of two different indirect preparations. Comparisons between high-flow rate samplers and low-flow rate samplers were made by calculating mass concentration ratios of coal dusts, net mass ratios of coal dusts, and quartz net mass. Mass concentrations of coal dust from the FSP10 cyclone were significantly higher than those from other samplers and mass concentrations of coal dust from 10-mm nylon cyclone were significantly lower than those from other samplers, while the CIP10-R, GK2.69, and BGI4L samplers did not show significant difference in the comparison of mass concentration of coal dusts. The BGI4L cyclone showed larger mass concentration of ~9% compared to the 10-mm nylon cyclone. All cyclones provided dust mass concentrations that can be used in complying with the International Standard Organization standard for the determination of respirable dust concentration. The amount of coal dust collected from the high-flow rate samplers was found to be higher with a factor of 2–8 compared to the low-flow rate samplers but not in direct proportion of increased flow rates. The high-flow rate samplers collected more quartz compared to

  6. Efficacy of a vacuum benthos sampler for collecting demersal fish eggs from gravel substratum

    USGS Publications Warehouse

    Ruetz, C. R., III; Jennings, C.A.

    1997-01-01

    We used two densities of eggs (low=900 eggs/m2; high=5100 eggs/m2) in laboratory experiments to estimate the recovery efficiency of the Brown benthos sampler for collecting fish eggs from gravel substrate and to determine if differences (e.g., 5-fold) in egg density in the substratum could be detected with the sampler. The mean egg recovery efficiency of the sampler in the low and high density treatments was 30% (SE=8.7) and 35% (SE=3.8), respectively. The difference between the treatment means was not significant. Therefore, data from the two treatments were pooled and used to estimate the recovery efficiency of the sampler (32.7%, SE=4.4). However, we were able to detect a 5?? difference in the number of eggs collected with the sampler between the two treatments. Our estimate of the recovery efficiency of the sampler for collecting fish eggs was less than those reported for the sampler's efficiency for collecting benthic macroinvertebrates. The low recovery efficiency of the sampler for collecting fish eggs does not lessen the utility of the device. Rather, ecologists planning to use the sampler must estimate the recovery efficiency of target fauna, especially if density estimates are to be calculated, because recovery efficiency probably is less than 100%. ?? Munksgaard, 1997.

  7. Estimation of membrane diffusion coefficients and equilibration times for low-density polyethylene passive diffusion samplers.

    PubMed

    Divine, Craig E; McCray, John E

    2004-03-15

    Passive diffusion (PD) samplers offer several potential technical and cost-related advantages, particularly for measuring dissolved gases and volatile organic compounds (VOCs) in groundwater at contaminated sites. Sampler equilibration is a diffusion-type process; therefore, equilibration time is dependent on sampler dimensions, membrane thickness, and the temperature-dependent membrane diffusion coefficient (Dm) for the analyte of interest. Diffusion coefficients for low-density polyethylene membranes were measured for He, Ne, H2, O2, and N2 in laboratory experiments and ranged from 1.1 to 1.9 x 10(-7) cm2 sec(-1) (21 degrees C). Additionally, Dm values for several commonly occurring VOCs were estimated from empirical experimental data previously presented by others (Vroblesky, D. A.; Campbell, T. R. Adv. Environ. Res. 2001, 5(1), 1.), and estimated values ranged from 1.7 to 4.4 x 10(-7) cm2 sec(-1) (21 degrees C). On the basis of these Dm ranges, PD sampler equilibration time is predicted for various sampler dimensions, including dimensions consistent with simple constructed samplers used in this study and commercially available samplers. Additionally, a numerical model is presented that can be used to evaluate PD sampler concentration "lag time" for conditions in which in situ concentrations are temporally variable. The model adequately predicted lag time for laboratory experiments and is used to show that data obtained from appropriately designed PD samplers represent near-instantaneous measurement of in situ concentrations for most field conditions. PMID:15074699

  8. Modeling the uptake of neutral organic chemicals on XAD passive air samplers under variable temperatures, external wind speeds and ambient air concentrations (PAS-SIM).

    PubMed

    Armitage, James M; Hayward, Stephen J; Wania, Frank

    2013-01-01

    The main objective of this study was to evaluate the performance and demonstrate the utility of a fugacity-based model of XAD passive air samplers (XAD-PAS) designed to simulate the uptake of neutral organic chemicals under variable temperatures, external wind speeds and ambient air concentrations. The model (PAS-SIM) simulates the transport of the chemical across the air-side boundary layer and within the sampler medium, which is segmented into a user-defined number of thin layers. Model performance was evaluated using data for polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) from a field calibration study (i.e., active and XAD-PAS data) conducted in Egbert, Ontario, Canada. With some exceptions, modeled PAS uptake curves are in good agreement with the empirical PAS data. The results are highly encouraging, given the uncertainty in the active air sampler data used as input and other uncertainties related to model parametrization (e.g., sampler-air partition coefficients, the influence of wind speed on sampling rates). The study supports the further development and evaluation of the PAS-SIM model as a diagnostic (e.g., to aid interpretation of calibration studies and monitoring data) and prognostic (e.g., to inform design of future passive air sampling campaigns) tool. PMID:24175752

  9. Calibration of high flow rate thoracic-size selective samplers.

    PubMed

    Lee, Taekhee; Thorpe, Andrew; Cauda, Emanuele; Harper, Martin

    2016-01-01

    High flow rate respirable size selective samplers, GK4.126 and FSP10 cyclones, were calibrated for thoracic-size selective sampling in two different laboratories. The National Institute for Occupational Safety and Health (NIOSH) utilized monodisperse ammonium fluorescein particles and scanning electron microscopy to determine the aerodynamic particle size of the monodisperse aerosol. Fluorescein intensity was measured to determine sampling efficiencies of the cyclones. The Health Safety and Laboratory (HSL) utilized a real time particle sizing instrument (Aerodynamic Particle Sizer) and polydisperse glass sphere particles and particle size distributions between the cyclone and reference sampler were compared. Sampling efficiency of the cyclones were compared to the thoracic convention defined by the American Conference of Governmental Industrial Hygienists (ACGIH)/Comité Européen de Normalisation (CEN)/International Standards Organization (ISO). The GK4.126 cyclone showed minimum bias compared to the thoracic convention at flow rates of 3.5 l min(-1) (NIOSH) and 2.7-3.3 l min(-1) (HSL) and the difference may be from the use of different test systems. In order to collect the most dust and reduce the limit of detection, HSL suggested using the upper end in range (3.3 l min(-1)). A flow rate of 3.4 l min(-1) would be a reasonable compromise, pending confirmation in other laboratories. The FSP10 cyclone showed minimum bias at the flow rate of 4.0 l min(-1) in the NIOSH laboratory test. The high flow rate thoracic-size selective samplers might be used for higher sample mass collection in order to meet analytical limits of quantification. PMID:26891196

  10. Passive flux sampler for measurement of formaldehyde emission rates

    NASA Astrophysics Data System (ADS)

    Shinohara, Naohide; Fujii, Minoru; Yamasaki, Akihiro; Yanagisawa, Yukio

    A new passive flux sampler (PFS) was developed to measure emission rates of formaldehyde and to determine emission sources in indoor environments. The sampler consisted of a glass Petri dish containing a 2,4-dinitrophenyl hydrazine (DNPH)-impregnated sheet. At the start of sampling, the PFS was placed with the open face of the dish on each of the indoor materials under investigation, such as flooring, walls, doors, closets, desks, beds, etc. Formaldehyde emitted from a source material diffused through the inside of the PFS and was adsorbed onto the DNPH sheet. The formaldehyde emission rates could be determined from the quantities adsorbed. The lower determination limits were 9.2 and 2.3 μg m -2 h -1 for 2- and 8-h sampling periods. The recovery rate and the precision of the PFS were 82.9% and 8.26%, respectively. The emission rates measured by PFS were in good agreement with the emission rates measured by the chamber method ( R2=0.963). This shows that it is possible to take measurements of the formaldehyde emission rates from sources in a room and to compare them. In addition, the sampler can be used to elucidate the emission characteristics of a source by carrying out emission measurements with different air-layer thicknesses inside the PFS and at different temperatures. The dependency of the emission rate on the thickness of the air layer inside the PFS indicated whether the internal mass transfer inside the source material or the diffusion in the gas-phase boundary layer controlled the formaldehyde emission rate from a material. In addition, as a pilot study, the formaldehyde emission rates were measured, and the largest emission source of formaldehyde could be identified from among several suspected materials in a model house by using the PFS.

  11. Calibration of high flow rate thoracic-size selective samplers

    PubMed Central

    Lee, Taekhee; Thorpe, Andrew; Cauda, Emanuele; Harper, Martin

    2016-01-01

    High flow rate respirable size selective samplers, GK4.126 and FSP10 cyclones, were calibrated for thoracic-size selective sampling in two different laboratories. The National Institute for Occupational Safety and Health (NIOSH) utilized monodisperse ammonium fluorescein particles and scanning electron microscopy to determine the aerodynamic particle size of the monodisperse aerosol. Fluorescein intensity was measured to determine sampling efficiencies of the cyclones. The Health Safety and Laboratory (HSL) utilized a real time particle sizing instrument (Aerodynamic Particle Sizer) and poly-disperse glass sphere particles and particle size distributions between the cyclone and reference sampler were compared. Sampling efficiency of the cyclones were compared to the thoracic convention defined by the American Conference of Governmental Industrial Hygienists (ACGIH)/Comité Européen de Normalisation (CEN)/International Standards Organization (ISO). The GK4.126 cyclone showed minimum bias compared to the thoracic convention at flow rates of 3.5 l min−1 (NIOSH) and 2.7–3.3 l min−1 (HSL) and the difference may be from the use of different test systems. In order to collect the most dust and reduce the limit of detection, HSL suggested using the upper end in range (3.3 l min−1). A flow rate of 3.4 l min−1 would be a reasonable compromise, pending confirmation in other laboratories. The FSP10 cyclone showed minimum bias at the flow rate of 4.0 l min−1 in the NIOSH laboratory test. The high flow rate thoracic-size selective samplers might be used for higher sample mass collection in order to meet analytical limits of quantification. PMID:26891196

  12. Using the Gibbs Motif Sampler for Phylogenetic Footprinting

    SciTech Connect

    Thompson, William; Conlan, Sean; McCue, Lee Ann; Lawrence, Charles

    2007-07-01

    The Gibbs Motif Sampler (Gibbs) (1) is a software package used to predict conserved elements in biopolymer sequences. While the software can be used to locate conserved motifs in protein sequences, its most common use is the prediction of transcription factor binding sites (TFBSs) in promoters upstream of gene sequences. We will describe approaches that use Gibbs to locate TFBSs in a collection of orthologous nucleotide sequences, i.e. phylogenetic footprinting. To illustrate this technique, we present examples that use Gibbs to detect binding sites for the transcription factor LexA in orthologous sequence data from representative species belonging to two different proteobacterial divisions.

  13. Soil separator and sampler and method of sampling

    DOEpatents

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  14. Energy storage considerations for a robotic Mars surface sampler

    NASA Technical Reports Server (NTRS)

    O'Donnell, P. M.; Cataldo, R. L.; Gonzalez-Sanabria, O. D.

    1988-01-01

    The characteristics of various energy storage systems (including Ni-Cd, Ni-H2, Ag-Zn, Li-XS, Na-S, PbSO4, and regenerative fuel cell systems) considered for a robotic Mars surface sampler are reviewed. It is concluded that the bipolar nickel-hydrogen battery and the sodium-sulfur battery are both viable candidates as storage systems for the rover's Radioisotope Thermoelectric Generator. For a photovoltaic storage system, the regenerative fuel cell and the bipolar nickel-hydrogen battery are the primary candidates.

  15. Planning/Evaluation Report for In-School Suspension, Grades 6-12.

    ERIC Educational Resources Information Center

    Gordon, Randy

    The 1989/90 In-School Suspension (ISS) program of the Des Moines (Iowa) Independent Community School District provided an in-school setting for the suspension of students in 15 secondary schools for infractions of the discipline code while continuing their educational program and focusing on the offending behavior through counseling activities.…

  16. A-Gay-Yah: A Gender Equity Curriculum for Grades 6-12.

    ERIC Educational Resources Information Center

    American Indian Resource Center, Tahlequah, OK.

    This two-part guide frames gender equity lessons within the context of Native American history and culture, thereby increasing student awareness and knowledge in these key equity areas as they study U.S. history and social studies. Part 1, "Understanding Gender Equity," describes activities that increase student understanding of general gender…

  17. Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens

    NASA Astrophysics Data System (ADS)

    Adhikari, Atin; Martuzevicius, Dainius; Reponen, Tiina; Grinshpun, Sergey A.; Cho, Seung-Hyun; Sivasubramani, Satheesh K.; Zhong, Wei; Levin, Linda; Kelley, Anna L.; St. Clair, Harry G.; LeMasters, Grace

    No personal aerosol sampler has been evaluated for monitoring aeroallergens in outdoor field conditions and compared to conventional stationary aerobiological samplers. Recently developed Button Personal Inhalable Aerosol Sampler has demonstrated high sampling efficiency for non-biological particles and low sensitivity to the wind direction and velocity. The aim of the present study was to evaluate the Button Sampler for the measurement of outdoor pollen grains and fungal spores side-by-side with the widely used Rotorod Sampler. The sampling was performed for 8 months (spring, summer and fall) at a monitoring station on the roof of a two-storied office building located in the center of the city of Cincinnati. Two identical Button Samplers, one oriented towards the most prevalent wind and the other towards the opposite wind and a Rotorod Sampler were placed side-by-side. The total fungal spore concentration ranged from 129 to 12,980 spores m -3 (number per cubic meter of air) and the total pollen concentration from 4 to 4536 pollen m -3. The fungal spore concentrations obtained with the two Button Samplers correlated well ( r=0.95; p<0.0001). The pollen data also showed positive correlation. These findings strongly support the results of earlier studies conducted with non-biological aerosol particles, which demonstrated a low wind dependence of the performance of the Button Sampler compared to other samplers. The Button Sampler's inlet efficiency was found to be more dependent on wind direction when sampling larger sized Pinaceae pollen grains (aerodynamic diameter ≈65 μm). Compared to Rotorod, both Button Samplers measured significantly higher total fungal spore concentrations. For total pollen count, the Button Sampler facing the prevalent wind showed concentrations levels comparable to that of the Rotorod, but the Button Sampler oriented opposite to the prevalent wind demonstrated lower concentration levels. Overall, it was concluded that the Button Sampler is

  18. Field evaluation and calibration of a small axial passive air sampler for gaseous and particle bound polycyclic aromatic hydrocarbons (PAHs) and oxygenated PAHs.

    PubMed

    Magnusson, Roger; Arnoldsson, Kristina; Lejon, Christian; Hägglund, Lars; Wingfors, Håkan

    2016-09-01

    Polycyclic aromatic hydrocarbons (PAHs) and their oxygenated analogues (OPAHs) are ubiquitous air pollutants known to cause adverse health effects. PAH air levels are commonly monitored by active sampling but passive sampling has become popular because of its lower cost and simplicity, which facilitate long-term sampling and increased spatial coverage. However, passive samplers are less suitable for short-term sampling and are in general less accurate than active samplers because they require reliable sampling rate (Rs) measurements for individual analytes under diverse environmental conditions. In this study a small passive sampler designed to sample both particle-bound and gaseous compounds was evaluated and calibrated for PAHs and OPAHs in a traffic environment by co-deployment with active samplers for two weeks. Despite the relatively low average air concentrations of PM10 (20 μg/m(3)), PM2.5 (5 μg/m(3)), total PAHs (4.2 ng/m(3)), and OPAHs (2.3 ng/m(3)) at the site, detectable quantities (on average 24 times above blank values) of the full range of PAHs and OPAHs were captured, with low variability (average RSD of 16%). This was accomplished by using a Tenax(®) TA-modified glass fiber substrate that is compatible with highly sensitive thermal desorption GC-MS analysis, which made it possible to achieve detection limits per sample in the pg range. Experiments with inverted samplers revealed that the relative contribution of gravitational settling to the sampling of particles carrying PAHs and OPAHs was around 3.5 times larger than other deposition mechanisms. Average Rs values for individual OPAHs and PAHs were 0.046 ± 0.03 m(3)/day and 0.12 ± 0.07 m(3)/day, respectively, with no appreciable difference between the values for particle-associated and gaseous compounds. Furthermore, the Rs values were competitive with other currently used passive samplers if normalized for substrate area. Overall, the new sampler's performance, simplicity and

  19. Equilibration times, compound selectivity, and stability of diffusion samplers for collection of ground-water VOC concentrations

    USGS Publications Warehouse

    Vroblesky, D.A.; Campbell, T.R.

    2001-01-01

    Vapor-filled polyethylene diffusion samplers (typically used to locate discharge zones of volatile organic compound contaminated ground water beneath streams and lakes) and water-filled polyethylene diffusion bag samplers (typically used to obtain volatile organic compound concentrations in ground-water at wells) were tested to determine compound selectivity, equilibration times, and sample stability. The aqueous concentrations of several volatile organic compounds obtained from within water-filled diffusion samplers closely matched concentrations in ambient water outside the samplers. An exception was methyl-tert-butyl ether, which was detectable, but not reliably quantifiable using the diffusion samplers. The samplers equilibrated to a variety of volatile organic compounds within 24 h for vapor-filled passive diffusion vial samplers and within 48 h for water-filled passive diffusion bag samplers. Under field conditions, however, a longer equilibration time may be required to account for environmental disturbances caused by sampler deployment. An equilibrium period for both vapor- and water-filled diffusion samplers of approximately 2 weeks probably is adequate for most investigations in sandy formations. Longer times may be required for diffusion-sampler equilibration in poorly permeable sediment. The vapor-filled samplers should be capped and water from the diffusion bag samplers should be transferred to sampling vials immediately upon recovery to avoid volatilization losses of the gasses. ?? 2001 Elsevier Science Ltd.

  20. Gradient-based MCMC samplers for dynamic causal modelling

    PubMed Central

    Sengupta, Biswa; Friston, Karl J.; Penny, Will D.

    2016-01-01

    In this technical note, we derive two MCMC (Markov chain Monte Carlo) samplers for dynamic causal models (DCMs). Specifically, we use (a) Hamiltonian MCMC (HMC-E) where sampling is simulated using Hamilton’s equation of motion and (b) Langevin Monte Carlo algorithm (LMC-R and LMC-E) that simulates the Langevin diffusion of samples using gradients either on a Euclidean (E) or on a Riemannian (R) manifold. While LMC-R requires minimal tuning, the implementation of HMC-E is heavily dependent on its tuning parameters. These parameters are therefore optimised by learning a Gaussian process model of the time-normalised sample correlation matrix. This allows one to formulate an objective function that balances tuning parameter exploration and exploitation, furnishing an intervention-free inference scheme. Using neural mass models (NMMs)—a class of biophysically motivated DCMs—we find that HMC-E is statistically more efficient than LMC-R (with a Riemannian metric); yet both gradient-based samplers are far superior to the random walk Metropolis algorithm, which proves inadequate to steer away from dynamical instability. PMID:26213349

  1. Novel multi-slit large-volume air sampler.

    PubMed

    Buchanan, L M; Decker, H M; Frisque, D E; Phillips, C R; Dahlgren, C M

    1968-08-01

    Scientific investigators who are interested in the various facets of airborne transmission of disease in research laboratories and hospitals need a simple, continuous, high-volume sampling device that will recover a high percentage of viable microorganisms from the atmosphere. Such a device must sample a large quantity of air. It should effect direct transfer of the air into an all-purpose liquid medium in order to collect bacteria, viruses, rickettsia, and fungi, and it should be easy to use. A simple multi-slit impinger sampler that fulfills these requirements has been developed. It operates at an air-sampling rate of 500 liters/min, has a high collection efficiency, functions at a low pressure drop, and, in contrast to some earlier instruments, does not depend upon electrostatic precipitation at high voltages. When compared to the all-glass impinger, the multi-slit impinger sampler collected microbial aerosols of Serratia marcescens at 82% efficiency, and aerosols of Bacillus subtilis var. niger at 78% efficiency. PMID:4970892

  2. An Application of Passive Samplers to Understand Atmospheric Mercury Concentration and Dry Deposition Spatial Distributions

    EPA Science Inventory

    Two modified passive samplers were evaluated at multiple field locations. The sampling rate (SR) of the modified polyurethane foam (PUF)-disk passive sampler for total gaseous mercury (TGM) using gold-coated quartz fiber filters (GcQFF) and gaseous oxidized mercury (GOM) using io...

  3. EVALUATION OF THE HARVARD OZONE PASSIVE SAMPLER ON HUMAN SUBJECTS INDOORS

    EPA Science Inventory

    A small, inexpensive ozone passive sampler was developed by Koutrakis et al. (1) to provide a convenient means for measuring ozone. This paper presents validation results of the Harvard ozone passive sampler and investigation of ozone behavior around the human body through a seri...

  4. THE USE OF INDUSTRIAL HYGIENE SAMPLERS FOR SOIL-GAS MEASUREMENT

    EPA Science Inventory

    This report describes a field evaluation of a passive-sampling technique for soil-gas surveying. The system uses a sampler, consisting of an industrial hygiene organic vapor monitor inside a metal sampling manifold, buried at a depth of approximately 0.3 meters (1 foot). Samplers...

  5. Performance Evaluation of Automated Passive Capillary Sampler for Estimating Water Drainage in the Vadose Zone

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Passive capillary samplers (PCAPs) are widely used to monitor, measure and sample drainage water under saturated and unsaturated soil conditions in the vadose zone. The objective of this study was to evaluate the performance and accuracy of automated passive capillary sampler for estimating drainage...

  6. 50 CFR 260.57 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false How samples are drawn by inspectors or... drawn by inspectors or licensed samplers. An inspector or a licensed sampler shall select samples, upon... representative sample of the lot. Samples drawn for inspection shall be furnished by the applicant at no cost...

  7. FIELD STUDY RESULTS FOR VOCS WITH THE PERKIN-ELMER SEQUENTIAL TUBE SAMPLER

    EPA Science Inventory

    Two Perkin-Elmer Sequential Tube Samplers (Model STS-25) were evaluated for their performance, portability, and convenience of operation. esults obtained from both samplers and from a collocated Summa-polished stainless steel canister were compared for seven 3-h periods at three ...

  8. Water flux and drainage from soil measured with automated passive capillary wick samplers

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Various soil water samplers are used to monitor measure and estimate drainage water, fluxes and solute transport in the soil vadose zone. Passive capillary samplers (PCAPs) have shown potential to provide better measurements and estimates of soil water drainage and fluxes than other lysimeters.Twelv...

  9. Effects of Hardness on Pintle Rod Performance in the Universal and Retained Gas Samplers

    SciTech Connect

    BOGER, R.M.

    1999-11-18

    Interaction between hardness of the pintle rods and the retainer rings used in the core samplers is investigated. It is found that ordinary Rockwell C measurements are not sufficient and superficial hardness instruments are recommended to verify hardness since in-production hardness of pintle rods is found to vary widely and probably leads to some premature release of pistons in samplers.

  10. 50 CFR 260.50 - Suspension or revocation of license of licensed sampler or licensed inspector.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Suspension or revocation of license of... Licensing of Samplers and Inspectors § 260.50 Suspension or revocation of license of licensed sampler or... or evidence that he may wish to offer as to why his license should not be suspended or revoked....

  11. 40 CFR 1065.341 - CVS and batch sampler verification (propane check).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false CVS and batch sampler verification... Measurements § 1065.341 CVS and batch sampler verification (propane check). (a) A propane check serves as a CVS... system that extracts a sample from a CVS, as described in paragraph (g) of this section. Using...

  12. 50 CFR 260.57 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 11 2013-10-01 2013-10-01 false How samples are drawn by inspectors or... drawn by inspectors or licensed samplers. An inspector or a licensed sampler shall select samples, upon... representative sample of the lot. Samples drawn for inspection shall be furnished by the applicant at no cost...

  13. 50 CFR 260.57 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 11 2012-10-01 2012-10-01 false How samples are drawn by inspectors or... drawn by inspectors or licensed samplers. An inspector or a licensed sampler shall select samples, upon... representative sample of the lot. Samples drawn for inspection shall be furnished by the applicant at no cost...

  14. 50 CFR 260.57 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 9 2011-10-01 2011-10-01 false How samples are drawn by inspectors or... drawn by inspectors or licensed samplers. An inspector or a licensed sampler shall select samples, upon... representative sample of the lot. Samples drawn for inspection shall be furnished by the applicant at no cost...

  15. INNOVATIVE TECHNOLOGY EVALUATION REPORT, SEDIMENT SAMPLING TECHNOLOGY, ART'S MANUFACTURING, SPLIT CORE SAMPLER FOR SUBMERGED SEDIMENTS

    EPA Science Inventory


    The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at ...

  16. Samplers for evaluation and quantification of ultra-low volume space sprays

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A field study was conducted to investigate the suitability of sampling devices for quantification of spray deposition from ULV space sprays. Five different samplers were included in an experiment conducted in an open grassy field. Samplers included horizontally stretched stationary cotton ribbon at ...

  17. Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites

    EPA Science Inventory

    Passive samplers are monitoring tools that can provide faster, cheaper, and scientifically-sound information about the water column and interstitial water concentrations of contaminants of concern (COC) at Superfund sites. Often, the use of passive samplers is more effective tha...

  18. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... specified in 40 CFR part 50, appendix L or appendix O, as applicable. The test requirements and performance... specified for a reference method sampler in 40 CFR part 50, appendix L or appendix O, as applicable, such as... air flow splitting components that may be used in a Class I candidate equivalent method sampler...

  19. MODIFICATION AND EVALUATION OF A HIGH-VOLUME AIR SAMPLER FOR PESTICIDES AND SEMIVOLATILE INDUSTRIAL ORGANIC CHEMICALS

    EPA Science Inventory

    Previously we reported the development and evaluation of a high-volume air sampler for pesticides and other semivolatile industrial organic chemicals (1). This sampler has proved useful for monitoring airborne pesticides associated with agricultural applications (2) and polychlor...

  20. Convergence of the Equi-Energy Sampler and Its Application to the Ising Model.

    PubMed

    Hua, Xia; Kou, S C

    2011-10-01

    We provide a complete proof of the convergence of a recently developed sampling algorithm called the equi-energy (EE) sampler (Kou, Zhou, and Wong, 2006) in the case that the state space is countable. We show that in a countable state space, each sampling chain in the EE sampler is strongly ergodic a.s. with the desired steady-state distribution. Furthermore, all chains satisfy the individual ergodic property. We apply the EE sampler to the Ising model to test its efficiency, comparing it with the Metropolis algorithm and the parallel tempering algorithm. We observe that the dynamic exponent of the EE sampler is significantly smaller than those of parallel tempering and the Metropolis algorithm, demonstrating the high efficiency of the EE sampler. PMID:21969801

  1. Assembly, operation and disassembly manual for the Battelle Large Volume Water Sampler (BLVWS)

    SciTech Connect

    Thomas, V.W.; Campbell, R.M.

    1984-12-01

    Assembly, operation and disassembly of the Battelle Large Volume Water Sampler (BLVWS) are described in detail. Step by step instructions of assembly, general operation and disassembly are provided to allow an operator completely unfamiliar with the sampler to successfully apply the BLVWS to his research sampling needs. The sampler permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and fresh water. The water sample passes through a filtration section for particle removal then through sorption or ion exchange beds where species of interest are removed. The sampler components which contact the water being sampled are constructed of polyvinylchloride (PVC). The sampler has been successfully applied to many sampling needs over the past fifteen years. 9 references, 8 figures.

  2. A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.

    PubMed

    Lidén, Göran; Surakka, Jouni

    2009-03-01

    There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use and can be mounted inside modern, slimline welder's face shield. The mini sampler is based on a commercially available 13-mm filter holder that has been modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini sampler is 0.75 l min(-1). The mini sampler is to be worn mounted on a headset, modified from professional microphone headsets. Several aspects related to using the mini sampler have been tested by personal and static sampling at five workplaces and in the laboratory. Four headset models were tested for their suitability as a sampler holder, of which three models were accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler and the open-face 25-mm filter holder, respectively, depends on the size distribution of the sampled aerosol. At the lowest encountered mass concentration ratio of the open-face 25-mm filter holder to the IOM sampler (0.65), the sampling bias of the mini sampler versus the IOM sampler is approximately -26% and versus the open-face 25-mm filter holder is approximately +12%. For manganese, the negative root mean square (RMS) sampling bias of the mini sampler versus the IOM sampler is -0.046 and versus the open-face 25-mm filter holder is non-significant. Both these biases are statistically non-significant. The mini sampler can therefore be employed for determining welders' occupational exposure to manganese. The pressure drop across the filter can become excessive due to the small filtration area. Compared to the Casella Apex pump, the SKC AirChek2000 pump was generally found to be able

  3. The impact of foot arch height on quality of life in 6-12 year olds

    PubMed Central

    Bouza Prego, Mª de los Ángeles; Requeijo Constenla, Ana; Saleta Canosa, Jesús Luis; Bautista Casasnovas, Adolfo; Tajes, Francisco Alonso

    2014-01-01

    Objective: To determine whether arch height has an effect on the health-related quality of life of schoolchildren. Methods: One hundred and thirteen schoolchildren attended an out-patient centre where self-reported data were recorded, their feet were classified into one of three groups according to their arch index (high, normal or low) and the scores obtained from the Foot Health Status Questionnaire (FHSQ - Spanish version) were compared. Results: The groups with high, low and normal arch recorded lower scores in Section One for the general foot health and footwear domains and higher scores in foot pain and foot function. In Section Two they obtained lower scores in general health and higher scores in physical activity, social capacity and vigour. Conclusions: Comparison of the scores obtained reveals that arch height has a negative impact on quality of life. Given the limited extent of available evidence in respect of the aetiology and treatment of foot diseases and deformities, these findings reveal the need to implement programmes to promote foot health and carry out further research into this commonly occurring disabling condition. PMID:25767305

  4. Teachers and Students Investigating Plants in Space. A Teacher's Guide with Activities for Life Sciences. Grades 6-12.

    ERIC Educational Resources Information Center

    Williams, Paul H.

    The Collaborative Ukrainian Experiment (CUE) was a joint mission between the United States and the Ukraine (Russia) whose projects were designed to address specific questions about prior plant science microgravity experiments. The education project that grew out of this, Teachers and Students Investigating Plants in Space (TSIPS), involved…

  5. Exceptions: A Handbook of Inclusion Activities for Teachers of Students at Grades 6-12 with Mild Disabilities. Second Edition.

    ERIC Educational Resources Information Center

    Murphy, Deborah A.; And Others

    This book includes ideas, strategies, techniques, and lessons for the inclusion of students with mild disabilities in regular classes (grades 6 through 12). An introduction discusses inclusion in the context of federal legislation, the continuum of services model, essential personnel, and inclusion models. The first section of the main text…

  6. Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study.

    PubMed

    Lee, Taekhee; Harper, Martin; Kashon, Michael; Lee, Larry A; Healy, Catherine B; Coggins, Marie A; Susi, Pam; O'Brien, Andrew

    2016-04-01

    High and low flow rate respirable size selective samplers including the CIP10-R (10 l min(-1)), FSP10 (11.2 l min(-1)), GK2.69 (4.4 l min(-1)), 10-mm nylon (1.7 l min(-1)), and Higgins-Dewell type (2.2 l min(-1)) were compared via side-by-side sampling in workplaces for respirable crystalline silica measurement. Sampling was conducted at eight different occupational sites in the USA and five different stonemasonry sites in Ireland. A total of 536 (268 pairs) personal samples and 55 area samples were collected. Gravimetric analysis was used to determine respirable dust mass and X-ray diffraction analysis was used to determine quartz mass. Ratios of respirable dust mass concentration, quartz mass concentration, respirable dust mass, and quartz mass from high and low flow rate samplers were compared. In general, samplers did not show significant differences greater than 30% in respirable dust mass concentration and quartz mass concentration when outliers (ratio <0.3 or >3.0) were removed from the analysis. The frequency of samples above the limit of detection and limit of quantification of quartz was significantly higher for the CIP10-R and FSP10 samplers compared to low flow rate samplers, while the GK2.69 cyclone did not show significant difference from low flow rate samplers. High flow rate samplers collected significantly more respirable dust and quartz than low flow rate samplers as expected indicating that utilizing high flow rate samplers might improve precision in quartz measurement. Although the samplers did not show significant differences in respirable dust and quartz concentrations, other practical attributes might make them more or less suitable for personal sampling. PMID:26608952

  7. Silica Measurement with High Flow Rate Respirable Size Selective Samplers: A Field Study

    PubMed Central

    Lee, Taekhee; Harper, Martin; Kashon, Michael; Lee, Larry A.; Healy, Catherine B.; Coggins, Marie A.; Susi, Pam; O’Brien, Andrew

    2016-01-01

    High and low flow rate respirable size selective samplers including the CIP10-R (10 l min−1), FSP10 (11.2 l min−1), GK2.69 (4.4 l min−1), 10-mm nylon (1.7 l min−1), and Higgins-Dewell type (2.2 l min−1) were compared via side-by-side sampling in workplaces for respirable crystalline silica measurement. Sampling was conducted at eight different occupational sites in the USA and five different stonemasonry sites in Ireland. A total of 536 (268 pairs) personal samples and 55 area samples were collected. Gravimetric analysis was used to determine respirable dust mass and X-ray diffraction analysis was used to determine quartz mass. Ratios of respirable dust mass concentration, quartz mass concentration, respirable dust mass, and quartz mass from high and low flow rate samplers were compared. In general, samplers did not show significant differences greater than 30% in respirable dust mass concentration and quartz mass concentration when outliers (ratio <0.3 or >3.0) were removed from the analysis. The frequency of samples above the limit of detection and limit of quantification of quartz was significantly higher for the CIP10-R and FSP10 samplers compared to low flow rate samplers, while the GK2.69 cyclone did not show significant difference from low flow rate samplers. High flow rate samplers collected significantly more respirable dust and quartz than low flow rate samplers as expected indicating that utilizing high flow rate samplers might improve precision in quartz measurement. Although the samplers did not show significant differences in respirable dust and quartz concentrations, other practical attributes might make them more or less suitable for personal sampling. PMID:26608952

  8. A sample-freezing drive shoe for a wire line piston core sampler

    SciTech Connect

    Murphy, F.; Herkelrath, W.N.

    1996-11-01

    Loss of fluids and samples during retrieval of cores of saturated, noncohesive sediments results in incorrect measures of fluid distributions and an inaccurate measure of the stratigraphic position of the sample. To reduce these errors, the authors developed a hollow drive shoe that freezes in place the lowest 3 inches (75 mm) of a 1.88-inch -diameter (48 mm), 5-foot-long (1.5 m) sediment sample taken using a commercial wire line piston core sampler. The end of the core is frozen by piping liquid carbon dioxide at ambient temperature through a steel tube from a bottle at the land surface to the drive shoe where it evaporates and expands, cooling the interior surface of the shoe to about {minus}109 F ({minus}78 C). Freezing a core end takes about 10 minutes. The device was used to collect samples for a study of oil-water-air distributions, and for studies of water chemistry and microbial activity in unconsolidated sediments at the site of an oil spill near Bemidji, Minnesota. Before freezing was employed, samples of sandy sediments from near the water table sometimes flowed out of the core barrel as the sampler was withdrawn. Freezing the bottom of the core allowed for the retention of all material that entered the core barrel and lessened the redistribution of fluids within the core. The device is useful in the unsaturated and shallow saturated zones, but does not freeze cores well at depths greater than about 20 feet (6 m) below water, possibly because the feed tube plugs with dry ice with increased exhaust back-pressure, or because sediment enters the annulus between the core barrel and the core barrel liner and blocks the exhaust.

  9. A sample-freezing drive shoe for a wire line piston core sampler

    USGS Publications Warehouse

    Murphy, F.; Herkelrath, W.N.

    1996-01-01

    Loss of fluids and samples during retrieval of cores of saturated, noncohesive sediments results in incorrect measures of fluid distributions and an inaccurate measure of the stratigraphic position of the sample. To reduce these errors, we developed a hollow drive shoe that freezes in place the lowest 3 inches (75 mm) of a 1.88-inch-diameter (48 mm), 5-foot-long (1.5 m) sediment sample taken using a commercial wire line piston core sampler. The end of the core is frozen by piping liquid carbon dioxide at ambient temperature through a steel tube from a bottle at the land surface to the drive shoe where it evaporates and expands, cooling the interior surface of the shoe to about -109??F (-78??C). Freezing a core end takes about 10 minutes. The device was used to collect samples for a study of oil-water-air distributions, and for studies of water chemistry and microbial activity in unconsolidated sediments at the site of an oil spill near Bemidji, Minnesota. Before freezing was employed, samples of sandy sediments from near the water table sometimes flowed out of the core barrel as the sampler was withdrawn. Freezing the bottom of the core allowed for the retention of all material that entered the core barrel and lessened the redistribution of fluids within the core. The device is useful in the unsaturated and shallow saturated zones, but does not freeze cores well at depths greater than about 20 feet (6 m) below water, possibly because the feed tube plugs with dry ice with increased exhaust back-pressure, or because sediment enters the annulus between the core barrel and the core barrel liner and blocks the exhaust.

  10. X-ray spectrum in the range (6-12) A emitted by laser-produced plasma of samarium

    SciTech Connect

    Louzon, Einat; Henis, Zohar; Levi, Izhak; Hurvitz, Gilad; Ehrlich, Yosi; Fraenkel, Moshe; Maman, Shlomo; Mandelbaum, Pinchas

    2009-05-15

    A detailed analysis of the x-ray spectrum emitted by laser-produced plasma of samarium (6-12 A) is presented, using ab initio calculations with the HULLAC relativistic code and isoelectronic considerations. Resonance 3d-nf (n=4 to 7), 3p-4d, 3d-4p, and 3p-4s transitions in Ni samarium ions and in neighboring ionization states (from Mn to Zn ions) were identified. The experiment results show changes in the fine details of the plasma spectrum for different laser intensities.

  11. Operating manual for Ford's Farm Range air samplers

    SciTech Connect

    Glissmeyer, J.A.; Halverson, M.A.

    1980-10-01

    An air-sampling program was designed for a target enclosure at the Ford's Farm Range, Aberdeen Proving Ground, Maryland, where the Army test-fires tungsten and depleted-uranium armor penetrators. The primary potential particle inhalation hazard is depleted uranium. The sampling program includes workplace and filtered exhaust air sampling. Conventional isokinetic stack sampling was employed for the filtered exhaust air. Because of the need for rapid monitor response to concentration increases and decreases, conventional radioactive particle monitors were not used. Instead, real-time aerosol monitors employing a light-scattering technique were used for monitors requiring a fast response. For other monitoring functions, piezoelectric and beta-attenuation respirable-particle sampling techniques were used. The application of these technologies to the monitoring of airborne radioactive contaminants is addressed. Sampler installation and operation are detailed.

  12. Two-Stage Variable Sample-Rate Conversion System

    NASA Technical Reports Server (NTRS)

    Tkacenko, Andre

    2009-01-01

    A two-stage variable sample-rate conversion (SRC) system has been pro posed as part of a digital signal-processing system in a digital com munication radio receiver that utilizes a variety of data rates. The proposed system would be used as an interface between (1) an analog- todigital converter used in the front end of the receiver to sample an intermediatefrequency signal at a fixed input rate and (2) digita lly implemented tracking loops in subsequent stages that operate at v arious sample rates that are generally lower than the input sample r ate. This Two-Stage System would be capable of converting from an input sample rate to a desired lower output sample rate that could be var iable and not necessarily a rational fraction of the input rate.

  13. A simple pore water hydrogen diffusion syringe sampler

    USGS Publications Warehouse

    Vroblesky, D.A.; Chapelle, F.H.; Bradley, P.M.

    2007-01-01

    Molecular hydrogen (H2) is an important intermediate product and electron donor in microbial metabolism. Concentrations of dissolved H 2 are often diagnostic of the predominant terminal electron-accepting processes in ground water systems or aquatic sediments. H2 concentrations are routinely measured in ground water monitoring wells but are rarely measured in saturated aquatic sediments due to a lack of simple and practical sampling methods. This report describes the design and development (including laboratory and field testing) of a simple, syringe-based H 2 sampler in (1) saturated, riparian sediments, (2) surface water bed sediments, and (3) packed intervals of a fractured bedrock borehole that are inaccessible by standard pumped methods. ?? 2007 National Ground Water Association.

  14. Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

    USGS Publications Warehouse

    Zimmerman, Marc J.; Vroblesky, Don A.; Campo, Kimberly W.; Massey, Andrew J.; Scheible, Walter

    2005-01-01

    Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a

  15. Albatrosses as Ocean Samplers of Sea Surface Temperature

    NASA Astrophysics Data System (ADS)

    Shaffer, S. A.; Kappes, M.; Tremblay, Y.; Costa, D. P.; Weber, R.; Weimerskirch, H.

    2006-12-01

    Albatrosses are unique ocean voyagers because they range so widely and travel at speeds exceeding 90 km per hour. Because they can integrate vast areas of open-ocean, albatrosses are ideal ocean samplers. Between 2003 and 2005 breeding seasons, 21 Laysan and 15 black-footed albatrosses (body mass 2.5 to 3.5 kg) were equipped with 6 g leg-mounted geolocation archival data loggers at Tern Island, French Frigate Shoals, Northwest Hawaiian Islands. The tags sampled environmental temperatures every 480 or 540 s and provided a single location per day for the duration of deployment. Whenever an albatross landed on the sea surface to feed or rest, the tag sampled sea surface temperature (SST). After nearly one year of deployment, 31 albatrosses were recaptured and 29 tags provided complete records. A total of 377,455 SST readings were obtained over 7,360 bird-days at sea. Given the location errors in the geolocation methodology (200 km) and the lack of temporal resolution (1 location per day), the SST measurements can only be used to characterize broad-scale correlates between albatross distribution and the ocean environment. However, in February 2006, we deployed 45 g GPS data loggers on 10 breeding albatrosses for 2-4 day deployments. The GPS loggers were attached to feathers on the albatrosses backs, they sampled every 10 s, and were accurate to within 10 m. One albatross was also equipped with the same leg-mounted archival tag that sampled SST every 8 s. This albatross collected 6,289 SST measurements with complementary GPS quality locations in 3 days at sea. These results highlight the efficacy of albatrosses as ocean samplers. Given that Laysan and black- footed albatrosses range throughout the North Pacific Ocean, it is conceivable that these seabirds could someday become sentinels of changing oceanic conditions. Moreover, these technologies provide exciting new information about the oceanic habitats of North Pacific albatrosses.

  16. Determining the spatial variability of personal sampler inlet locations

    SciTech Connect

    Vinson, R.; Volkwein, J.; Mcwilliams, L.

    2007-09-15

    This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose. The calculated percentage differences of the masses ranged from plus 12% to minus 25%. Breathing zone tests were also conducted in four underground coal mines using the torso of a mannequin to simulate a miner. Coal mine dust was sampled with multi-cyclone sampling cans mounted directly in front of the mannequin near the cap lamp, nose, and lapel. These four coal mine tests found that the spatial variability of dust levels and imprecision of the current personal sampler is a greater influence than the sampler location within the breathing zone. However, a one-sample t-test of this data did find that the overall mean value of the cap lamp/nose ratio was not significantly different than 1 (p-value = 0.21). However; when applied to the overall mean value of the lapel/nose ratio there was a significant difference from 1 (p-value < 0.0001). This finding is important because the lapel has always been the sampling location for coal mine dust samples. But these results suggest that the cap location is slightly more indicative of what is breathed through the nose area.

  17. Development of a new semi-volatile organic compound sampler

    SciTech Connect

    Sioutas, C.; Koutrakis, P.; Burton, R.M.

    1994-12-31

    A new sampler has been developed to sample semi-volatile organic compounds. The sampler utilizes the principle of virtual impactor to efficiently separate the particulate from the gas phases of organic compounds. The virtual impactor consists of a slit-shaped nozzle where the aerosol is accelerated, and another slit-shaped nozzle that collects the particulate phase of organics (plus a small and known fraction of the gas phase). The acceleration slit is 0.023 cm wide, the collection slit is 0.035 cm wide, and both slits are 11 cm long. The virtual impactor`s 50% cutpoint has been determined experimentally to be 0.12 {micro}m. In addition, interstage losses have been determined (in all configurations tested, particle losses ranged from 5--15%). The impactor`s sampling flow rate is 284 liters/minute, with a corresponding pressure drop of 100 inches H{sub 2}O. Higher or lower sampling flow rates can be achieved by increasing or decreasing the length of the slits. Tests for volatilization losses have been conducted by generating organic aerosols of known volatility, and comparing the impactor`s collection to that of a filter pack sampling in parallel. The experiments demonstrated negligible volatilization losses (< 5%) for the compounds tried. Particles are collected on a filter connected to the minor flow of the impactor, followed by a sorbent bed to collect material that volatilized from the particles. The organic gas phases is collected on a sorbent bed, connected to the major flow of the impactor.

  18. Design Optimization of a Portable Thermophoretic Precipitator Nanoparticle Sampler

    PubMed Central

    Miller, Art; Marinos, Alek; Wendel, Chris; King, Grant; Bugarski, Aleksandar

    2015-01-01

    Researchers at the National Institute for Occupational Safety and Health (NIOSH) are developing methods for characterizing diesel particulate matter in mines. Introduction of novel engine and exhaust after treatment technologies in underground mines is changing the nature of diesel emissions, and metrics alternative to the traditional mass-based measurements are being investigated with respect to their ability to capture changes in the properties of diesel aerosols. The emphasis is given to metrics based on measurement of number and surface area concentrations, but analysis of collected particles using electron microscopy (EM) is also employed for detailed particle characterization. To collect samples for EM analysis at remote workplaces, including mining and manufacturing facilities, NIOSH is developing portable particle samplers capable of collecting airborne nano-scale particles. This paper describes the design, construction, and testing of a prototype thermophoretic precipitator (TP) particle sampler optimized for collection of particles in the size range of 1–300 nm. The device comprises heated and cooled metal plates separated by a 0.8 mm channel through which aerosol is drawn by a pump. It weighs about 2 kg, has a total footprint of 27 × 22 cm, and the collection plate size is approximately 4 × 8 cm. Low power consumption and enhanced portability were achieved by using moderate flow rates (50–150 cm3/min) and temperature gradients (10–50 K/mm with ΔT between 8 K and 40 K). The collection efficiency of the prototype, measured with a condensation particle counter using laboratory-generated polydisperse submicrometer NaCl aerosols, ranged from 14–99%, depending on temperature gradient and flow rate. Analysis of transmission electron microscopy images of samples collected with the TP confirmed that the size distributions of collected particles determined using EM are in good agreement with those determined using a Fast Mobility Particle Sizer. PMID

  19. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings

    PubMed Central

    Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.

    2014-01-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149

  20. AN AFFINE-INVARIANT SAMPLER FOR EXOPLANET FITTING AND DISCOVERY IN RADIAL VELOCITY DATA

    SciTech Connect

    Hou Fengji; Hogg, David W.; Goodman, Jonathan; Weare, Jonathan; Schwab, Christian

    2012-02-01

    Markov chain Monte Carlo (MCMC) proves to be powerful for Bayesian inference and in particular for exoplanet radial velocity fitting because MCMC provides more statistical information and makes better use of data than common approaches like chi-square fitting. However, the nonlinear density functions encountered in these problems can make MCMC time-consuming. In this paper, we apply an ensemble sampler respecting affine invariance to orbital parameter extraction from radial velocity data. This new sampler has only one free parameter, and does not require much tuning for good performance, which is important for automatization. The autocorrelation time of this sampler is approximately the same for all parameters and far smaller than Metropolis-Hastings, which means it requires many fewer function calls to produce the same number of independent samples. The affine-invariant sampler speeds up MCMC by hundreds of times compared with Metropolis-Hastings in the same computing situation. This novel sampler would be ideal for projects involving large data sets such as statistical investigations of planet distribution. The biggest obstacle to ensemble samplers is the existence of multiple local optima; we present a clustering technique to deal with local optima by clustering based on the likelihood of the walkers in the ensemble. We demonstrate the effectiveness of the sampler on real radial velocity data.

  1. Evaluation of the polyurethane foam (PUF) disk passive air sampler: Computational modeling and experimental measurements

    NASA Astrophysics Data System (ADS)

    May, Andrew A.; Ashman, Paul; Huang, Jiaoyan; Dhaniyala, Suresh; Holsen, Thomas M.

    2011-08-01

    Computational fluid dynamics (CFD) simulations coupled with wind tunnel-experiments were used to determine the sampling rate (SR) of the widely used polyurethane foam (PUF) disk passive sampler. In the wind-tunnel experiments, water evaporation rates from a water saturated PUF disk installed in the sampler housing were determined by measuring weight loss over time. In addition, a modified passive sampler designed to collect elemental mercury (Hg 0) with gold-coated filters was used. Experiments were carried out at different wind speeds and various sampler angles. The SRs obtained from wind-tunnel experiments were compared to those obtained from the field by scaling the values by the ratios of air diffusivities. Three-dimensional (3D) CFD simulations were also used to generate SRs for both polychlorinated biphenyls (PCBs) and Hg 0. Overall, the modeled and measured SRs agree well and are consistent with the values obtained from field studies. As previously observed, the SRs increased linearly with increasing wind speed. In addition, it was determined that the SR was strongly dependent on the angle of the ambient wind. The SRs increased when the base was tilted up pointing into the wind and when the base was tilted down (i.e., such that the top of the sampler was facing the wind) the SR decreased initially and then increased. The results suggest that there may be significant uncertainty in concentrations obtained from passive sampler measurements without knowledge of wind speed and wind angle relative to the sampler.

  2. Exploring the role of the sampler housing in limiting uptake of semivolatile organic compounds in passive air samplers.

    PubMed

    Zhang, Xianming; Hoang, Michelle; Lei, Ying D; Wania, Frank

    2015-12-01

    Passive air samplers (PASs) are simple, versatile devices that are increasingly used to determine the concentrations of semivolatile organic compounds (SVOCs) in the atmosphere. Using PAS and interpreting PAS-derived data with confidence requires a detailed understanding of the factors that control the uptake kinetics. A number of experiments were aimed at clarifying the role that the housing has in limiting the uptake of SVOCs in a PAS. Specifically, we quantified the gradient in the amount of polychlorinated biphenyls (PCBs) accumulated in XAD-filled mesh cylinders with increasing distance from the PAS housing's opening. That gradient was non-existent in an artificially ventilated housing (i.e. different segments of a cylinder contained the same amount of PCBs), minor during outdoor deployments (i.e. the bottom third of the cylinder sampled approximately 20% more PCBs than the top third), and strong during indoor deployments (i.e. the bottom third of the cylinder sampled twice the amount sampled by the top third). This is consistent with the thickness of the air boundary layer surrounding the XAD-resin increasing with increasing distance from the housing's opening and decreasing with increasing air turbulence. An experiment with housings absorbing different amounts of sunlight revealed that heat-induced convection has a minor effect on the gradient within the mesh cylinder and on the total amount of accumulated PCB. Similarly, this gradient and the total amount sorbed was also not influenced by the number of XAD-filled mesh cylinders placed within a housing as long as they were deployed outdoors. However, if four mesh cylinders were placed in one housing in a calm indoor setting, the top third of the mesh cylinders was notably starved of PCBs, suggestive of an air concentration gradient within the sampler housing. PMID:26598925

  3. Engineering Task Plan for Preparing the Type 4 In Situ Vapor Samplers (ISVS) for Use

    SciTech Connect

    BOGER, R.M.

    2000-01-06

    The DOE has identified a need to sample vapor space and exhaust ducts of several waste tanks The In-Situ Vapor Sampling (ISVS) Type IV vapor sampling cart has been identified as the appropriate monitoring tool. The ISVS carts have been out of service for a number of years. This ETP outlines the work to be performed to ready the type IV gas sampler for operation Characterization Engineering will evaluate the Type IV gas sampler carts to determine their state of readiness and will proceed to update procedures and equipment documentation to make the sampler operationally acceptable.

  4. Airborne influenza virus detection with four aerosol samplers using molecular and infectivity assays: considerations for a new infectious virus aerosol sampler

    PubMed Central

    Fabian, P.; McDevitt, J. J.; Houseman, E. A.; Milton, D. K.

    2013-01-01

    As a first step in conducting studies of airborne influenza transmission, we compared the collection performance of an SKC Biosampler, a compact cascade impactor (CCI), Teflon filters, and gelatin filters by collecting aerosolized influenza virus in a one-pass aerosol chamber. Influenza virus infectivity was determined using a fluorescent focus assay and influenza virus nucleic acid (originating from viable and non-viable viruses) was measured using quantitative PCR. The results showed that the SKC Biosampler recovered and preserved influenza virus infectivity much better than the other samplers – the CCI, Teflon, and gelatin filters recovered only 7–22% of infectious viruses compared with the Biosampler. Total virus collection was not significantly different among the SKC Biosampler, the gelatin, and Teflon filters, but was significantly lower in the CCI. Results from this study show that a new sampler is needed for virus aerosol sampling, as commercially available samplers do not efficiently collect and conserve virus infectivity. Applications for a new sampler include studies of airborne disease transmission and bioterrorism monitoring. Design parameters for a new sampler include high collection efficiency for fine particles and liquid sampling media to preserve infectivity. PMID:19689447

  5. Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

    PubMed

    Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G

    2004-06-01

    While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger

  6. UK AMD EMR USERS GROUP REPORT V: benefits of initiating ranibizumab therapy for neovascular AMD in eyes with vision better than 6/12

    PubMed Central

    Lee, Aaron Y; Lee, Cecilia S; Butt, Thomas; Xing, Wen; Johnston, Robert L; Chakravarthy, Usha; Egan, Catherine; Akerele, Toks; McKibbin, Martin; Downey, Louise; Natha, Salim; Bailey, Clare; Khan, Rehna; Antcliff, Richard; Varma, Atul; Kumar, Vineeth; Tsaloumas, Marie; Mandal, Kaveri; Liew, Gerald; Keane, Pearse A; Sim, Dawn; Bunce, Catey; Tufail, Adnan

    2015-01-01

    Background/aims To study the effectiveness and clinical relevance of eyes treated with good (better than 6/12 or >70 Early Treatment Diabetic Retinopathy Study letters) visual acuity (VA) when initiating treatment with ranibizumab for neovascular age-related macular degeneration (nAMD) in the UK National Health Service. Currently eyes with VA better than (>) 6/12 are not routinely funded for therapy. Methods Multicentre national nAMD database study on patients treated 3–5 years prior to the analysis. Anonymised structured data were collected from 14 centres. The primary outcome was the mean VA at year 1, 2 and 3. Secondary measures included the number of clinic visits and injections. Results The study included 12 951 treatment-naive eyes of 11 135 patients receiving 92 976 ranibizumab treatment episodes. A total of 754 patients had baseline VA better than 6/12 and at least 1-year of follow up. Mean VA of first treated eyes with baseline VA>6/12 at year 1, 2, 3 were 6/10, 6/12, 6/15, respectively and those with baseline VA 6/12 to >6/24 were 6/15, 6/17, 6/20, respectively (p values <0.001 for comparing differences between 6/12 and 6/12–6/24 groups). For the second eyes with baseline VA>6/12, mean VA at year 1, 2, 3 were 6/9, 6/9, 6/10 and those with baseline VA 6/12 to >6/24 were 6/15, 6/15, 6/27, respectively (p values <0.001–0.005). There was no significant difference in the average number of clinic visits or injections between those with VA better and worse than 6/12. Conclusions All eyes with baseline VA>6/12 maintained better mean VA than the eyes with baseline VA 6/12 to >6/24 at all time points for at least 2 years. The significantly better visual outcome in patients who were treated with good baseline VA has implications on future policy regarding the treatment criteria for nAMD patients’ funding. PMID:25680619

  7. High efficiency CIP 10-I personal inhalable aerosol sampler

    NASA Astrophysics Data System (ADS)

    Görner, P.; Wrobel, R.; Simon, X.

    2009-02-01

    The CIP 10 personal aerosol sampler was first developed by Courbon for sampling the respirable fraction of mining dust. This respirable aerosol sampler was further improved by Fabries, then selectors for sampling thoracic and inhalable aerosols were designed. Kenny et al. evaluated the particle-size dependent sampling efficiency of the inhalable version in a large-scale wind tunnel using a life-size dummy. The authors found that the overall sampling efficiency decreases more rapidly than the CEN-ISO-ACGIH target efficiency curve. Görner and Witschger measured the aspiration efficiency of the CIP 10 omni-directional inlet. They found that the aspiration efficiency was high enough for inhalable aerosol sampling. This result led to the conclusion that the low sampling efficiency is due to some internal losses of the aspirated particles before they reach the final sampling stage, namely the CIP 10 rotating filter. Based on the assumption that the inhalable particles are selected at selector aspiration level, an experimental research project was conducted to improve particle transmission to the collection stage of the sampler. Two different inhalable selectors were designed by Görner and tested in a laboratory wind tunnel. The transmission efficiency of both models was measured by Roger following an experimental protocol described by Witschger. The T-shaped air flow circuit was finally adopted to draw the aspirated particles into the final collection stage of the CIP 10. Actually, in this selector, the almost horizontally aspirated particles should be conducted vertically to the rotating cup. In two previous prototypes, particles could be deposited in certain places by inertia (where the aerosol was forced to deviate drastically) or by sedimentation (where the aerosol decelerated). The aerodynamic behaviour of the adopted solution causes the particles to accelerate radially between two horizontal plates before they enter a vertical tube. This acceleration avoids the

  8. Hg196 and the ``magical quartet'' of the extended Uν(6/12)⊗Uπ(6/4) supersymmetry

    NASA Astrophysics Data System (ADS)

    Bernards, C.; Heinze, S.; Jolie, J.; Albers, M.; Fransen, C.; Radeck, D.

    2010-02-01

    We present the results of a γγ angular correlation experiment investigating the nucleus Hg196 and compare these with a theoretical description of Hg196 within the Uν(6/12)⊗Uπ(6/4) extended supersymmetry. To populate excited Hg196 states, we used the Cologne FN Tandem accelerator inducing the reaction Pt194(α,2n)Hg196 and analyzed the γ decays of levels up to an excitation energy of 2.4 MeV with the HORUS cube spectrometer. The new results on this mercury isotope allow a comparison between the experimental data and the supersymmetrical predictions and show good agreement. This way we can add Hg196 as a fifth supermultiplet member to the so-called magical quartet consisting of Pt194,195 and Au195,196.

  9. A TWO STAGE RESPIRABLE AEROSOL SAMPLER USING NUCLEPORE FILTERS IN SERIES

    EPA Science Inventory

    Respirable and nonrespirable particles are separately collected from the atmosphere in a size selective sampler consisting of two Nuclepore filters in series. The first filter has pore diameters of 12 micrometers and collects, to a close approximation, the nonrespirable fraction ...

  10. A remotely operated serial sampler for collecting gas-tight fluid samples

    NASA Astrophysics Data System (ADS)

    Wu, Shi-jun; Yang, Can-jun; Ding, Kang; Tan, Chun-yang

    2015-10-01

    This paper describes the design, construction and preliminary test results for a gas-tight serial sampler intended to be deployed at seafloor for long-term operation to take time-series fluid samples from deep-sea environments such as cold seeps, water column and hydrothermal vents. The serial sampler is a modular system that is based on independent and identical sampling modules, which are designed to collect six 160 ml gas-tight fluid samples maintained at high pressure to a depth of 4000 meters. With two working modes, the sampler can be deployed either with seafloor cabled observatory for remote control or as a stand-alone device for autonomous operation. A prototype of the instrument has been constructed and tested on the MARS cabled observatory for two months. The laboratory and field tests proved the success of the design and construction of the serial sampler, and indicated the potential for future ocean sciences.

  11. Comparison of flume and towing methods for verifying the calibration of a suspended-sediment sampler

    USGS Publications Warehouse

    Beverage, J.P.; Futrell, J.C.

    1986-01-01

    Suspended-sediment samplers must sample isokinetically (at stream velocity) in order to collect representative water samples of rivers. Each sampler solo by the Federal Interagency Sedimentation Project or by the U.S. Geological Survey Hydrologic Instrumentation Facility has been adjusted to sample isokinetically and tested in a flume to verify the calibration. The test program for a modified U.S. P-61 sampler provided an opportunity to compare flume and towing tank tests. Although the two tests yielded statistically distinct results, the difference between them was quite small. The conclusion is that verifying the calibration of any suspended-sediment sampler by either the flume or towing method should give acceptable results.

  12. Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water.

    PubMed

    Ahrens, Lutz; Daneshvar, Atlasi; Lau, Anna E; Kreuger, Jenny

    2016-01-01

    Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chemical integrative sampler POCIS-A, POCIS-B, SDB-RPS and C18 disk. The uptake of the selected compounds depended on their physicochemical properties, i.e., silicone rubber showed a better uptake for more hydrophobic compounds (log octanol-water partition coefficient (KOW) > 5.3), whereas POCIS-A, POCIS-B and SDB-RPS disk were more suitable for hydrophilic compounds (log KOW < 0.70). PMID:27584699

  13. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... may request any vessel issued a Federal limited access American lobster permit to carry a NMFS... issued a Federal limited access American lobster permit, if requested by the sea sampler/observer...

  14. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... may request any vessel issued a Federal limited access American lobster permit to carry a NMFS... issued a Federal limited access American lobster permit, if requested by the sea sampler/observer...

  15. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... may request any vessel issued a Federal limited access American lobster permit to carry a NMFS... issued a Federal limited access American lobster permit, if requested by the sea sampler/observer...

  16. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... may request any vessel issued a Federal limited access American lobster permit to carry a NMFS... issued a Federal limited access American lobster permit, if requested by the sea sampler/observer...

  17. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... may request any vessel issued a Federal limited access American lobster permit to carry a NMFS... issued a Federal limited access American lobster permit, if requested by the sea sampler/observer...

  18. A source of PCB contamination in modified high-volume air samplers

    SciTech Connect

    Basu, I.; O'Dell, J.M.; Arnold, K.; Hites, R.A.

    2000-02-01

    Modified Anderson High Volume (Hi-Vol) air samplers are widely used for the collection of semi-volatile organic compounds (such as PCBs) from air. The foam gasket near the main air flow path in these samplers can become contaminated with PCBs if the sampler or the gasket is stored at a location with high indoor air PCB levels. Once the gasket is contaminated, it releases PCBs back into the air stream during sampling, and as a result, incorrectly high air PCB concentrations are measured. This paper presents data demonstrating this contamination problem using measurements from two Integrated Atmospheric Deposition Network sites: one at Sleeping Bear Dunes on Lake Michigan and the other at Point Petre on Lake Ontario. The authors recommend that these gaskets be replaced by Teflon tape and that the storage history of each sampler be carefully tracked.

  19. Evaluating PCB Bioavailability Using Passive Samplers and Mussles at a Contaminated Sediment Site

    EPA Science Inventory

    Passive samplers, including semi-permeable membrane devices (SPMDs), solid phase microextraction (SPME) and polyethylene devices (PEDs), provide innovative tools for measuring hydrophobic organic contaminants (HOCs) originating from contaminated waters and sediments. Because the...

  20. Measuring freely dissolved water concentrations of PCBs using LDPE passive samplers and performance reference compounds (PRCs)

    EPA Science Inventory

    Low-Density polyethylene (LDPE) sheets are often used as passive samplers for aquatic environmental monitoring to measure the dissolved concentrations of hydrophobic organic contaminants (HOCs). These concentrations are then used to evaluate the potential for ecological and human...

  1. On the efficiency and correction of vertically oriented blunt bioaerosol samplers in moving air

    NASA Astrophysics Data System (ADS)

    Michel, Dominik; Rotach, Mathias W.; Gehrig, Regula; Vogt, Roland

    2012-11-01

    The aspiration efficiency of vertical and wind-oriented Air-O-Cell samplers was investigated in a field study using the pollen of hazel, sweet chestnut and birch. Collected pollen numbers were compared to measurements of a Hirst-type Burkard spore trap. The discrepancy between pollen counts is substantial in the case of vertical orientation. The results indicate a strong influence of wind velocity and inlet orientation relative to the freestream on the aspiration efficiency. Various studies reported on inertial effects on aerosol motion as function of wind velocity. The measurements were compared to a physically based model for the limited case of vertical blunt samplers. Additionally, a simple linear model based on pollen counts and wind velocity was developed. Both correction models notably reduce the error of vertically oriented samplers, whereas only the physically based model can be used on independent datasets. The study also addressed the precision error of the instruments used, which was substantial for both sampler types.

  2. Evaluating Cost when Selecting Performance Reference Compounds for the Environmental Deployment of Polyethylene Passive Samplers

    EPA Science Inventory

    A challenge in environmental passive sampling is determining when equilibrium is achieved between the sampler, target contaminants, and environmental phases. A common approach is the use of performance reference compounds (PRCs) to indicate degree of equilibrium. One logistical...

  3. Selecting Performance Reference Compounds (PRCS)for Polyethylene Passive Samplers Deployed at Contaminated Sediment Sites

    EPA Science Inventory

    Use of equilibrium passive samplers for performing aquatic environmental monitoring at contaminated sediment sites, including Superfund sites, is becoming more common. However, a current challenge in passive sampling is determining when equilibrium is achieved between the sampl...

  4. Use of a massive volume air sampler to collect fly ash for biological characterization

    SciTech Connect

    Cheng, Y.S.

    1984-06-01

    A massive volume air sampler (MVAS) with a flow rate of some 17/SUP/3/min and designed to collect ambient aerosols was modified for the collection of fly ash emissions from the stack mouth of an experimental fluidised bed combustor for physicochemical and biological characterisation. The sampler consisted of 2 impactor stages and an electrostatic precipitator section. High volume filter fly ash samples and laboratory size cascade impactor samples were obtained simultaneously to verify the operation of the MVAS.

  5. Evaluation of particle resuspension in young children's breathing zone using stationary and robotic (PIPER) aerosol samplers

    PubMed Central

    Sagona, Jessica A.; Shalat, Stuart L; Wang, Zuocheng; Ramagopal, Maya; Black, Kathleen; Hernandez, Marta; Mainelis, Gediminas

    2015-01-01

    Development of asthma in young children may be associated with high exposure to particulate matter (PM). However, typical stationary samplers may not represent the personal exposure of children ages 3 and younger since they may not detect particles resuspended from the floor as children play, thus reducing our ability to correlate exposure and disease etiology. To address this, an autonomous robot, the Pretoddler Inhalable Particulate Environmental Robotic (PIPER) sampler, was developed to simulate the movements of children as they play on the floor. PIPER and a stationary sampler took simultaneous measurements of particle number concentration in six size channels using an optical particle counter and inhalable PM on filters in 65 homes in New Jersey, USA. To study particle resuspension, for each sampler we calculated the ratio of particle concentration measured while PIPER was moving to the average concentration of particles measured during a reference period when PIPER remained still. For all investigated particle sizes, higher particle resuspension was observed by PIPER compared to the stationary sampler. In 71% of carpeted homes a more significant (at the α = 0.05 level) resuspension of particles larger than 2.5 μm was observed by PIPER compared to the stationary sampler. Typically, particles larger than 2.5 μm were resuspended more efficiently than smaller particles, over both carpeted and bare floors. Additionally, in carpeted homes estimations of PM10 mass from the particle number concentrations measured on PIPER while it was moving were on average a factor of 1.54 higher compared to reference period when PIPER was not moving. For comparison, the stationary sampler measured an increase of PM2.5 mass by a factor of only 1.08 when PIPER was moving compared to a reference period. This demonstrates that PIPER is able to resuspend particles through movement, and provide a better characterization of the resuspended particles than stationary samplers. Accurate

  6. Validation of a New Soil VOC Sampler: Precision of the Performance of the En Core Sampler to Store Low VOC Concentrations

    SciTech Connect

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani

    2002-06-01

    Soil sampling and storage practices for volatile organic analysis must be designed to minimize loss of volatile organic compounds (VOCs) from samples. The En Core{reg_sign} sampler is designed to collect and store soil samples in a manner that minimizes loss of contaminants due to volatilization and/or biodegradation. An American Society for Testing and Materials (ASTM) standard practice, D 6418, Standard Practice for Using the Disposable En Core Sampler for Sampling and Storing Soil for Volatile Organic Analysis, describes use of the En Core sampler to collect and store a soil sample of approximately 5 grams or 25 grams for volatile organic analysis. To support the ASTM practice, four studies have been performed to evaluate the performance of the En Core sampler for storage of soil samples spiked with VOCs. The first study was conducted to evaluate the performance of the device to store soil samples spiked with VOCs at high-level concentrations of approximately 2,500 {micro}g/Kg under various conditions. This analyte concentration in the soil was selected to limit the influence of the analytical method on the data. A second study was conducted to answer questions on the performance of the En Core sampler for storage of soil samples containing low-level (<200 {micro}g/Kg) concentrations of VOCs. In this study, soil samples were spiked with concentrations of VOCs at approximately 100 {micro}g/Kg and stored under various conditions prior to analysis. The third study was performed to generate data on the performance of the 25-gram En Core sampler to store soil samples spiked with EPA Method 1311, Toxicity Characteristic Leaching Procedure (TCLP), volatile organic analytes under various conditions for 14 days. The low-level performance data and TCLP analyte storage data are included in appendices to the ASTM practice, and the ASTM research report describing the high-level study is referenced in the practice. The fourth study, which is described in this report, was

  7. Numerical Evaluation of Lateral Diffusion Inside Diffusive Gradients in Thin Films Samplers

    PubMed Central

    2015-01-01

    Using numerical simulation of diffusion inside diffusive gradients in thin films (DGT) samplers, we show that the effect of lateral diffusion inside the sampler on the solute flux into the sampler is a nonlinear function of the diffusion layer thickness and the physical sampling window size. In contrast, earlier work concluded that this effect was constant irrespective of parameters of the sampler geometry. The flux increase caused by lateral diffusion inside the sampler was determined to be ∼8.8% for standard samplers, which is considerably lower than the previous estimate of ∼20%. Lateral diffusion is also propagated to the diffusive boundary layer (DBL), where it leads to a slightly stronger decrease in the mass uptake than suggested by the common 1D diffusion model that is applied for evaluating DGT results. We introduce a simple correction procedure for lateral diffusion and demonstrate how the effect of lateral diffusion on diffusion in the DBL can be accounted for. These corrections often result in better estimates of the DBL thickness (δ) and the DGT-measured concentration than earlier approaches and will contribute to more accurate concentration measurements in solute monitoring in waters. PMID:25877251

  8. Computational fluid dynamics (CFD) simulation of a newly designed passive particle sampler.

    PubMed

    Sajjadi, H; Tavakoli, B; Ahmadi, G; Dhaniyala, S; Harner, T; Holsen, T M

    2016-07-01

    In this work a series of computational fluid dynamics (CFD) simulations were performed to predict the deposition of particles on a newly designed passive dry deposition (Pas-DD) sampler. The sampler uses a parallel plate design and a conventional polyurethane foam (PUF) disk as the deposition surface. The deposition of particles with sizes between 0.5 and 10 μm was investigated for two different geometries of the Pas-DD sampler for different wind speeds and various angles of attack. To evaluate the mean flow field, the k-ɛ turbulence model was used and turbulent fluctuating velocities were generated using the discrete random walk (DRW) model. The CFD software ANSYS-FLUENT was used for performing the numerical simulations. It was found that the deposition velocity increased with particle size or wind speed. The modeled deposition velocities were in general agreement with the experimental measurements and they increased when flow entered the sampler with a non-zero angle of attack. The particle-size dependent deposition velocity was also dependent on the geometry of the leading edge of the sampler; deposition velocities were more dependent on particle size and wind speeds for the sampler without the bend in the leading edge of the deposition plate, compared to a flat plate design. Foam roughness was also found to have a small impact on particle deposition. PMID:27108045

  9. Use of Passive Diffusion Samplers for Monitoring Volatile Organic Compounds in Ground Water

    USGS Publications Warehouse

    Harte, Philip T.; Brayton, Michael J.; Ives, Wayne

    2000-01-01

    Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC's) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC's in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: * Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. * Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. * Reduction in sampling time by as much as 80 percent of that required for 'purge type' sampling methods. * An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.

  10. Stability of reduced sulfur compounds in whole air samplers

    SciTech Connect

    Tran, Q.; Tang, Y.Z.

    1994-12-31

    Reduced sulfur compounds can cause odor nuisance problems associated with kraft mill and sewage treatment operations. Accurate and reliable determination of reduced sulfur compounds is often required, but it is a challenging task due to the reactivity of reduced sulfur species and consequent difficulties in collection and storage of air samples. Several whole air samplers were evaluated for storage of reduced sulfur compounds at concentrations of 100 ppb (Tedlar bag only), 1 ppm and 100 ppm. Severe losses of H{sub 2}S and mercaptans were found in samples collected in electro-polished stainless steel canisters, although these canisters have been proven suitable for many volatile organic compounds. The losses of more volatile species were less severe than less volatile ones in Teflon vials, and glass and silanized glass bottles with Teflon-lined septum caps. In general, COS, CS{sub 2}, CH{sub 3}SCH{sub 3}, and CH{sub 3}SSCH{sub 3} were more stable than H{sub 2}S and mercaptans, and the reduced sulfur compounds were more stable in the Tedlar bag than in other sample containers.

  11. Radiation dependence of inverter propagation delay from timing sampler measurements

    NASA Technical Reports Server (NTRS)

    Buehler, M. G.; Blaes, B. R.; Lin, Y.-S.

    1989-01-01

    A timing sampler consisting of 14 four-stage inverter-pair chains with different load capacitances was fabricated in 1.6-micron n-well CMOS and irradiated with cobalt-60 at 10 rad(Si)/s. For this CMOS process the measured results indicate that the rising delay increases by about 2.2 ns/Mrad(Si) and the falling delay increase is very small, i.e., less than 300 ps/Mrad(Si). The amount of radiation-induced delay depends on the size of the load capacitance. The maximum value observed for this effect was 5.65 ns/pF-Mrad(Si). Using a sensitivity analysis, the sensitivity of the rising delay to radiation can be explained by a simple timing model and the radiation sensitivity of dc MOSFET parameters. This same approach could not explain the insensitivity of the falling delay to radiation. This may be due to a failure of the timing model and/or trapping effects.

  12. Development of a passive sampler for gaseous mercury

    NASA Astrophysics Data System (ADS)

    Gustin, M. S.; Lyman, S. N.; Kilner, P.; Prestbo, E.

    2011-10-01

    Here we describe work toward development of the components of a cost effective passive sampling system for gaseous Hg that could be broadly deployed by nontechnical staff. The passive sampling system included an external shield to reduce turbulence and exposure to precipitation and dust, a diffusive housing that directly protects the collection surface during deployment and handling, and a collection surface. A protocol for cleaning and deploying the sampler and an analytical method were developed. Our final design consisted of a polycarbonate external shield enclosing a custom diffusive housing made from expanded PTFE tubing. Two collection surfaces were investigated, gold sputter-coated quartz plates and silver wires. Research showed the former would require extensive quality control for use, while the latter had interferences with other atmosphere constituents. Although the gold surface exhibited the best performance over space and time, gradual passivation would limit reuse. For both surfaces lack of contamination during shipping, deployment and storage indicated that the handling protocols developed worked well with nontechnical staff. We suggest that the basis for this passive sampling system is sound, but further exploration and development of a reliable collection surface is needed.

  13. Statistical ranging of asteroid orbits: efficient MCMC and importance samplers

    NASA Astrophysics Data System (ADS)

    Virtanen, Jenni; Fedorets, Grigori; Granvik, Mikael; Oszkiewicz, Dagmara Anna; Muinonen, Karri

    2015-08-01

    We address the asteroid initial orbit computation problem by comparing various versions of the statistical ranging method (Virtanen et al. 2001, Muinonen et al. 2001) developed for exiguous observational data. In particular, the performance of the Markov-chain Monte Carlo (MCMC) ranging (Oszkiewicz et al. 2009) and the importance-sampler ranging methods, including the most recently developed random-walk ranging (Muinonen et al. 2015) are compared. We demonstrate the capabilities of the methods for various classes of asteroids, including near-Earth and main-belt asteroids, as well as transneptunian objects. We also study the performance of our statistical inverse methods as a function of increasing observational time interval, i.e., during the so-called phase transition. We also envision the application of the methods for space-debris orbits.Muinonen, K., Virtanen, J., Bowell, E., 2001. Collision probability for Earth-crossing asteroids using orbital ranging. Celestial Mechanics and Dynamical Astronomy 81, 93-101.Muinonen K., et al. 2015. Asteroid orbits from Gaia astrometry with random-walk statistical ranging, Planetary and Space Science, in preparation.Oszkiewicz, D., Muinonen, K., Virtanen, J., Granvik, M., 2009. Asteroid orbital ranging using Markov-chain Monte Carlo. Meteoritics and Planetary Science 44, 12, 1897-1904.Virtanen, J., Muinonen, K., Bowell, E., 2001. Statistical ranging of asteroid orbits. Icarus 154, 412-431.

  14. The Gillings Sampler--an electrostatic air sampler as an alternative method for aerosol in vitro exposure studies.

    PubMed

    Zavala, Jose; Lichtveld, Kim; Ebersviller, Seth; Carson, Johnny L; Walters, Glenn W; Jaspers, Ilona; Jeffries, Harvey E; Sexton, Kenneth G; Vizuete, William

    2014-09-01

    There is growing interest in studying the toxicity and health risk of exposure to multi-pollutant mixtures found in ambient air, and the U.S. Environmental Protection Agency (EPA) is moving towards setting standards for these types of mixtures. Additionally, the Health Effects Institute's strategic plan aims to develop and apply next-generation multi-pollutant approaches to understanding the health effects of air pollutants. There's increasing concern that conventional in vitro exposure methods are not adequate to meet EPA's strategic plan to demonstrate a direct link between air pollution and health effects. To meet the demand for new in vitro technology that better represents direct air-to-cell inhalation exposures, a new system that exposes cells at the air-liquid interface was developed. This new system, named the Gillings Sampler, is a modified two-stage electrostatic precipitator that provides a viable environment for cultured cells. Polystyrene latex spheres were used to determine deposition efficiencies (38-45%), while microscopy and imaging techniques were used to confirm uniform particle deposition. Negative control A549 cell exposures indicated the sampler can be operated for up to 4h without inducing any significant toxic effects on cells, as measured by lactate dehydrogenase (LDH) and interleukin-8 (IL-8). A novel positive aerosol control exposure method, consisting of a p-tolualdehyde (TOLALD) impregnated mineral oil aerosol (MOA), was developed to test this system. Exposures to the toxic MOA at a 1 ng/cm(2) dose of TOLALD yielded a reproducible 1.4 and 2-fold increase in LDH and IL-8 mRNA levels over controls. This new system is intended to be used as an alternative research tool for aerosol in vitro exposure studies. While further testing and optimization is still required to produce a "commercially ready" system, it serves as a stepping-stone in the development of cost-effective in vitro technology that can be made accessible to researchers in the

  15. The Gillings Sampler – An Electrostatic Air Sampler as an Alternative Method for Aerosol In Vitro Exposure Studies

    PubMed Central

    Zavala, Jose; Lichtveld, Kim; Ebersviller, Seth; Carson, Johnny L.; Walters, Glenn W.; Jaspers, Ilona; Jeffries, Harvey E.; Sexton, Kenneth G.; Vizuete, William

    2014-01-01

    There is growing interest in studying the toxicity and health risk of exposure to multi-pollutant mixtures found in ambient air, and the U.S. Environmental Protection Agency (EPA) is moving towards setting standards for these types of mixtures. Additionally, the Health Effects Institute's strategic plan aims to develop and apply next-generation multi-pollutant approaches to understanding the health effects of air pollutants. There's increasing concern that conventional in vitro exposure methods are not adequate to meet EPA's strategic plan to demonstrate a direct link between air pollution and health effects. To meet the demand for new in vitro technology that better represents direct air-to-cell inhalation exposures, a new system that exposes cells at the air-liquid interface was developed. This new system, named the Gillings Sampler, is a modified two-stage electrostatic precipitator that provides a viable environment for cultured cells. Polystyrene latex spheres were used to determine deposition efficiencies (38-45%), while microscopy and imaging techniques were used to confirm uniform particle deposition. Negative control A549 cell exposures indicated the sampler can be operated for up to 4 hours without inducing any significant toxic effects on cells, as measured by lactate dehydrogenase (LDH) and interleukin-8 (IL-8). A novel positive aerosol control exposure method, consisting of a p-tolualdehyde (TOLALD) impregnated mineral oil aerosol (MOA), was developed to test this system. Exposures to the toxic MOA at a 1 ng/cm2 dose of TOLALD yielded a reproducible 1.4 and 2 fold increase in LDH and IL-8 mRNA levels over controls. This new system is intended to be used as an alternative research tool for aerosol in vitro exposure studies. While further testing and optimization is still required to produce a “commercially ready” system, it serves as a stepping-stone in the development of cost-effective in vitro technology that can be made accessible to researchers

  16. Using structural equation modeling to construct calibration equations relating PM2.5 mass concentration samplers to the federal reference method sampler

    NASA Astrophysics Data System (ADS)

    Bilonick, Richard A.; Connell, Daniel P.; Talbott, Evelyn O.; Rager, Judith R.; Xue, Tao

    2015-02-01

    The objective of this study was to remove systematic bias among fine particulate matter (PM2.5) mass concentration measurements made by different types of samplers used in the Pittsburgh Aerosol Research and Inhalation Epidemiology Study (PARIES). PARIES is a retrospective epidemiology study that aims to provide a comprehensive analysis of the associations between air quality and human health effects in the Pittsburgh, Pennsylvania, region from 1999 to 2008. Calibration was needed in order to minimize the amount of systematic error in PM2.5 exposure estimation as a result of including data from 97 different PM2.5 samplers at 47 monitoring sites. Ordinary regression often has been used for calibrating air quality measurements from pairs of measurement devices; however, this is only appropriate when one of the two devices (the "independent" variable) is free from random error, which is rarely the case. A group of methods known as "errors-in-variables" (e.g., Deming regression, reduced major axis regression) has been developed to handle calibration between two devices when both are subject to random error, but these methods require information on the relative sizes of the random errors for each device, which typically cannot be obtained from the observed data. When data from more than two devices (or repeats of the same device) are available, the additional information is not used to inform the calibration. A more general approach that often has been overlooked is the use of a measurement error structural equation model (SEM) that allows the simultaneous comparison of three or more devices (or repeats). The theoretical underpinnings of all of these approaches to calibration are described, and the pros and cons of each are discussed. In particular, it is shown that both ordinary regression (when used for calibration) and Deming regression are particular examples of SEMs but with substantial deficiencies. To illustrate the use of SEMs, the 7865 daily average PM2.5 mass

  17. Field evaluation of a flow-through sampler for measuring pesticides and brominated flame retardants in the arctic atmosphere.

    PubMed

    Xiao, Hang; Hung, Hayley; Wania, Frank; Lao, Randy; Sabljic, Edwin; Sverko, Ed; Lei, Ying Duan; Fellin, Phil; Barresi, Enzo

    2012-07-17

    A flow-through sampler (FTS) was codeployed with a super high volume active sampler (SHV) between October 2007 and November 2008 to evaluate its ability to determine the ambient concentrations of pesticides and brominated flame retardants in the Canadian High Arctic atmosphere. Nine pesticides and eight flame retardants, including three polybrominated diphenyl ether (PBDE) replacement chemicals, were frequently detected. Atmospheric concentrations determined by the two systems showed good agreement when compared on monthly and annually integrated time scales. Pesticide concentrations were normally within a factor of 3 of each other. The FTS tended to generate higher PBDE concentrations than the SHV presumably because of the entrainment of blowing snow/ice crystals or large particles. Taking into account uncertainties in analytical bias, sample volume, and breakthrough estimations, the FTS is shown to be a reliable and cost-effective method, which derives seasonally variable concentrations of semivolatile organic trace compounds at extremely remote locations that are comparable to those obtained by conventional high volume air sampling. Moreover, the large sampling volumes captured by the FTS make it suitable for the screening of new and emerging chemicals in the remote atmosphere where concentrations are usually low. PMID:22702375

  18. Calibration of two passive air samplers for monitoring phthalates and brominated flame-retardants in indoor air.

    PubMed

    Saini, Amandeep; Okeme, Joseph O; Goosey, Emma; Diamond, Miriam L

    2015-10-01

    Two passive air samplers (PAS), polyurethane foam (PUF) disks and Sorbent Impregnated PUF (SIP) disks, were characterized for uptake of phthalates and brominated flame-retardants (BFRs) indoors using fully and partially sheltered housings. Based on calibration against an active low-volume air sampler for gas- and particle-phase compounds, we recommend generic sampling rates of 3.5±0.9 and 1.0±0.4 m(3)/day for partially and fully sheltered housing, respectively, which applies to gas-phase phthalates and BFRs as well as particle-phase DEHP (the later for the partially sheltered PAS). For phthalates, partially sheltered SIPs are recommended. Further, we recommend the use of partially sheltered PAS indoors and a deployment period of one month. The sampling rate for the partially sheltered PUF and SIP of 3.5±0.9 m(3)/day is indistinguishable from that reported for fully sheltered PAS deployed outdoors, indicating the role of the housing outdoors to minimize the effect of variable wind velocities on chemical uptake, versus the partially sheltered PAS deployed indoors to maximize chemical uptake where air flow rates are low. PMID:26189099

  19. Wood dust sampling: field evaluation of personal samplers when large particles are present.

    PubMed

    Lee, Taekhee; Harper, Martin; Slaven, James E; Lee, Kiyoung; Rando, Roy J; Maples, Elizabeth H

    2011-03-01

    Recent recommendations for wood dust sampling include sampling according to the inhalable convention of International Organization for Standardization (ISO) 7708 (1995) Air quality--particle size fraction definitions for health-related sampling. However, a specific sampling device is not mandated, and while several samplers have laboratory performance approaching theoretical for an 'inhalable' sampler, the best choice of sampler for wood dust is not clear. A side-by-side field study was considered the most practical test of samplers as laboratory performance tests consider overall performance based on a wider range of particle sizes than are commonly encountered in the wood products industry. Seven companies in the wood products industry of the Southeast USA (MS, KY, AL, and WV) participated in this study. The products included hardwood flooring, engineered hardwood flooring, door skins, shutter blinds, kitchen cabinets, plywood, and veneer. The samplers selected were 37-mm closed-face cassette with ACCU-CAP™, Button, CIP10-I, GSP, and Institute of Occupational Medicine. Approximately 30 of each possible pairwise combination of samplers were collected as personal sample sets. Paired samplers of the same type were used to calculate environmental variance that was then used to determine the number of pairs of samples necessary to detect any difference at a specified level of confidence. Total valid sample number was 888 (444 valid pairs). The mass concentration of wood dust ranged from 0.02 to 195 mg m(-3). Geometric mean (geometric standard deviation) and arithmetic mean (standard deviation) of wood dust were 0.98 mg m(-3) (3.06) and 2.12 mg m(-3) (7.74), respectively. One percent of the samples exceeded 15 mg m(-3), 6% exceeded 5 mg m(-3), and 48% exceeded 1 mg m(-3). The number of collected pairs is generally appropriate to detect a 35% difference when outliers (negative mass loadings) are removed. Statistical evaluation of the nonsimilar sampler pair results

  20. Wood Dust Sampling: Field Evaluation of Personal Samplers When Large Particles Are Present

    PubMed Central

    Lee, Taekhee; Harper, Martin; Slaven, James E.; Lee, Kiyoung; Rando, Roy J.; Maples, Elizabeth H.

    2011-01-01

    Recent recommendations for wood dust sampling include sampling according to the inhalable convention of International Organization for Standardization (ISO) 7708 (1995) Air quality—particle size fraction definitions for health-related sampling. However, a specific sampling device is not mandated, and while several samplers have laboratory performance approaching theoretical for an ‘inhalable’ sampler, the best choice of sampler for wood dust is not clear. A side-by-side field study was considered the most practical test of samplers as laboratory performance tests consider overall performance based on a wider range of particle sizes than are commonly encountered in the wood products industry. Seven companies in the wood products industry of the Southeast USA (MS, KY, AL, and WV) participated in this study. The products included hardwood flooring, engineered hardwood flooring, door skins, shutter blinds, kitchen cabinets, plywood, and veneer. The samplers selected were 37-mm closed-face cassette with ACCU-CAP™, Button, CIP10-I, GSP, and Institute of Occupational Medicine. Approximately 30 of each possible pairwise combination of samplers were collected as personal sample sets. Paired samplers of the same type were used to calculate environmental variance that was then used to determine the number of pairs of samples necessary to detect any difference at a specified level of confidence. Total valid sample number was 888 (444 valid pairs). The mass concentration of wood dust ranged from 0.02 to 195 mg m−3. Geometric mean (geometric standard deviation) and arithmetic mean (standard deviation) of wood dust were 0.98 mg m−3 (3.06) and 2.12 mg m−3 (7.74), respectively. One percent of the samples exceeded 15 mg m−3, 6% exceeded 5 mg m−3, and 48% exceeded 1 mg m−3. The number of collected pairs is generally appropriate to detect a 35% difference when outliers (negative mass loadings) are removed. Statistical evaluation of the nonsimilar sampler pair

  1. Facility fence-line monitoring using passive samplers.

    PubMed

    Thoma, Eben D; Miller, Michael C; Chung, Kuenja C; Parsons, Nicholas L; Shine, Brenda C

    2011-08-01

    In 2009, the U.S. Environmental Protection Agency (EPA) executed a year-long field study at a refinery in Corpus Christi, TX, to evaluate the use of passive diffusive sampling technology for assessing time-averaged benzene concentrations at the facility fence line. The purpose of the study was to investigate the implementation viability and performance of this type of monitoring in a real-world setting as part of EPA's fence-line measurement research program. The study utilized 14-day, time-integrated Carbopack X samplers deployed at 18 locations on the fence line and at two nearby air monitoring sites equipped with automated gas chromatographs. The average fence-line benzene concentration during the study was 1075 parts per trillion by volume (pptv) with a standard deviation of 1935 pptv. For a 6-month period during which wind direction was uniform, the mean concentration value for a group of downwind sites exceeded the mean value of a similar upwind group by 1710 pptv. Mean value differences for these groups were not statistically significant for the remaining 6-month time period when wind directions were mixed. The passive sampling approach exhibited acceptable performance with a data completeness value of 97.1% (n = 579). Benzene concentration comparisons with automated gas chromatographs yielded an r2 value of 0.86 and a slope of 0.90 (n = 50). A linear regression of duplicate pairs yielded an r2 of 0.97, unity slope, and zero intercept (n = 56). In addition to descriptions of technique performance and general results, time-series analyses are described, providing insight into the utility of 2-week sampling for source apportionment under differing meteorological conditions. The limitations of the approach and recommendations for future measurement method development work are also discussed. PMID:21874954

  2. Arduino-based control system for measuring ammonia in air using conditionally-deployed diffusive samplers

    NASA Astrophysics Data System (ADS)

    Ham, J. M.; Williams, C.; Shonkwiler, K. B.

    2012-12-01

    Arduino microcontrollers, wireless modules, and other low-cost hardware were used to develop a new type of air sampler for monitoring ammonia at strong areal sources like dairies, cattle feedlots, and waste treatment facilities. Ammonia was sampled at multiple locations on the periphery of an operation using Radiello diffusive passive samplers (Cod. RAD168- and RAD1201-Sigma-Aldrich). However, the samplers were not continuously exposed to the air. Instead, each sampling station included two diffusive samplers housed in specialized tubes that sealed the cartridges from the atmosphere. If a user-defined set of wind and weather conditions were met, the Radiellos were deployed into the air using a micro linear actuator. Each station was solar-powered and controlled by Arduinos that were linked to a central weather station using Xbee wireless modules (Digi International Inc.). The Arduinos also measured the total time of exposure using hall-effect sensors to verify the position of the cartridge (i.e., deployed or retracted). The decision to expose or retract the samplers was made every five minutes based on wind direction, wind speed, and time of day. Typically, the diffusive samplers were replaced with fresh cartridges every two weeks and the used samplers were analyzed in the laboratory using ion chromatography. Initial studies were conducted at a commercial dairy in northern Colorado. Ammonia emissions along the Front Range of Colorado can be transported into the mountains where atmospheric deposition of nitrogen can impact alpine ecosystems. Therefore, low-cost air quality monitoring equipment is needed that can be widely deployed in the region. Initial work at the dairy showed that ammonia concentrations ranged between 600 to 1200 ppb during the summer; the highest concentrations were downwind of a large anaerobic lagoon. Time-averaged ammonia concentrations were also used to approximate emissions using inverse dispersion models. This methodology provides a

  3. Field performance evaluation during fog-dominated wintertime of a newly developed denuder-equipped PM1 sampler.

    PubMed

    Singh, Dharmendra Kumar; Lakshay; Gupta, Tarun

    2014-03-01

    This study presents the performance evaluation of a novel denuder-equipped PM1 (particles having aerodynamic diameter less than 1 μm) sampler, tested during fog-dominated wintertime, in the city of Kanpur, India. One PM1 sampler and one denuder-equipped PM1 sampler were co-located to collect ambient PM1 for 25 days. The mean PM1 mass concentration measured on foggy days with the PM1 sampler and the denuder-equipped PM1 sampler was found to be 165.95 and 135.48 μg/m(3), respectively. The mean PM1 mass concentration measured on clear days with the PM1 sampler and the denuder-equipped PM1 sampler was observed to be 159.66 and 125.14 μg/m(3), respectively. The mass concentration with denuder-fitted PM1 sampler for both foggy and clear days was always found less than the PM1 sampler. The same drift was observed in the concentrations of water-soluble ions and water-soluble organic carbon (WSOC). Moreover, it was observed that the use of denuder leads to a significant reduction in the PM positive artifact. The difference in the concentration of chemical species obtained by two samplers indicates that the PM1 sampler without denuder had overestimated the concentrations of chemical species in a worst-case scenario by almost 40 %. Denuder-fitted PM1 sampler can serve as a useful sampling tool in estimating the true values for nitrate, ammonium, potassium, sodium and WSOC present in the ambient PM. PMID:24337990

  4. An Introduction to the DA-T Gibbs Sampler for the Two-Parameter Logistic (2PL) Model and beyond

    ERIC Educational Resources Information Center

    Maris, Gunter; Bechger, Timo M.

    2005-01-01

    The DA-T Gibbs sampler is proposed by Maris and Maris (2002) as a Bayesian estimation method for a wide variety of "Item Response Theory (IRT) models". The present paper provides an expository account of the DA-T Gibbs sampler for the 2PL model. However, the scope is not limited to the 2PL model. It is demonstrated how the DA-T Gibbs sampler for…

  5. Design and evaluation of a solid sampler for the monitoring of airborne 1,6-hexamethylene diisocyanate (HDI) and its prepolymers in two-component spray painting.

    PubMed

    Huynh, C K; Vu-Duc, T; Savolainen, H

    1992-03-01

    An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sampler. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X-0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60 micrograms/m3 (3 U.K. TLVs) for total -N=C=O groups. PMID:1642167

  6. Design and evaluation of a solid sampler for the monitoring of airborne 1,6-hexamethylene diisocyanate (HDI) and its prepolymers in two-component spray painting

    SciTech Connect

    Huynh, C.K.; Vu-Duc, T.; Savolainen, H. )

    1992-03-01

    An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sampler. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X-0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60 micrograms/m3 (3 U.K. TLVs) for total -N=C=O groups.

  7. Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Robson, Matthew; Helm, Paul A.; Diamond, Miriam L.

    2011-04-01

    Polyurethane foam (PUF) passive air samplers (PAS) are a common and highly useful method of sampling persistent organic pollutants (POP) concentrations in air. PAS calibration is necessary to obtain reasonable and comparable semi-quantitative measures of air concentrations. Various methods are found in the literature concerning PAS calibration. 35 studies on PAS use and calibration are examined here, in conjunction with a study involving 10 PAS deployed concurrently in outdoor air with a low-volume air sampler in order to measure the sampling rates of PUF-PAS for polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), polycyclic musks (PCMs), and polycyclic aromatic hydrocarbons (PAHs). Based on this analysis it is recommended that (1) PAS should be assumed to represent bulk rather than gas-phase compound concentrations due to the sampling of particle-bound compounds, (2) calibration of PAS sampling rates is more accurately achieved using an active low-volume air sampler rather than depuration compounds since the former measures gas- and particle-phase compounds and does so continuously over the deployment period of the PAS, and (3) homolog-specific sampling rates based on KOA groupings be used in preference to compound/congener-specific or single sampling rates.

  8. Uptake calibration of polymer-based passive samplers for monitoring priority and emerging organic non-polar pollutants in WWTP effluents.

    PubMed

    Posada-Ureta, Oscar; Olivares, Maitane; Zatón, Leire; Delgado, Alejandra; Prieto, Ailette; Vallejo, Asier; Paschke, Albrecht; Etxebarria, Nestor

    2016-05-01

    The uptake calibration of more than 12 non-polar organic contaminants by 3 polymeric materials is shown: bare polydimetilsiloxane (PDMS, stir-bars), polyethersulfone tubes and membranes (PES) and polyoxymethylene membranes (POM), both in their free form and membrane-enclosed sorptive coating (MESCO). The calibration process was carried out exposing the samplers to a continuous flow of contaminated water at 100 ng mL(-1) for up to 28 days, and, consequently, the sampling rates (Rs, mL day(-1)) of several organic microcontaminants were provided for the first time. In situ Rs values were also determined disposing the samplers in the effluent of a wastewater treatment plant. Finally, these passive samplers were applied to monitor the effluents of two wastewater treatment plants. This application lead to the confirmation of the presence of galaxolide, tonalide and 4-tert-octylphenol at high ng mL(-1) levels, as well as the identification of compounds like some phthalates and alkylphenols at levels below the detection limits for active sampling methods. PMID:26892638

  9. Effect of electrostatic charge on the aspiration efficiencies of airborne dust samplers: with special reference to asbestos

    SciTech Connect

    Johnston, A.M.; Jones, A.D.; Vincent, J.H.

    1987-07-01

    An experimental investigation has been conducted into the effects of electrostatic charge, carried by the dust particles and by the sampler itself, on the sampling of airborne dusts. Experiments covering both personal and static sampling and a range of sampler types were carried out in the laboratory for both fibrous asbestos and isometric silica gel dusts. Experiments also were carried out in the spinning shop of an asbestos textile factory. The results showed that the aspiration efficiency of the sampler always is reduced as the charge on the sampler increases, independently of the type of sampler and of whether it is used as a static or personal sampler. The effect is most marked when sampling takes place in calm air. It is concluded from the results that, for the levels of charge reached by samplers in most practical situations, the effects on aspiration efficiency will be small. Possible exceptions to this might occur, however, in workplace environments where relative humidity is very low, and charge levels of the sampler (or on the worker wearing the sampler) can become high.

  10. The effect of electrostatic charge on the aspiration efficiencies of airborne dust samplers: with special reference to asbestos.

    PubMed

    Johnston, A M; Jones, A D; Vincent, J H

    1987-07-01

    An experimental investigation has been conducted into the effects of electrostatic charge, carried by the dust particles and by the sampler itself, on the sampling of airborne dusts. Experiments covering both personal and static sampling and a range of sampler types were carried out in the laboratory for both fibrous asbestos and isometric silica gel dusts. Experiments also were carried out in the spinning shop of an asbestos textile factory. The results showed that the aspiration efficiency of the sampler always is reduced as the charge on the sampler increases, independently of the type of sampler and of whether it is used as a static or personal sampler. The effect is most marked when sampling takes place in calm air. It is concluded from the results that, for the levels of charge reached by samplers in most practical situations, the effects on aspiration efficiency will be small. Possible exceptions to this might occur, however, in workplace environments where relative humidity is very low, and charge levels of the sampler (or on the worker wearing the sampler) can become high. PMID:3039822

  11. Evaluation of passive diffusion bag and dialysis samplers in selected wells at Hickam Air Force Base, Hawaii, July 2001

    USGS Publications Warehouse

    Vroblesky, Don A.; Pravecek, Tasha

    2002-01-01

    Field comparisons of chemical concentrations obtained from dialysis samplers, passive diffusion bag samplers, and low-flow samplers showed generally close agreement in most of the 13 wells tested during July 2001 at Hickam Air Force Base, Hawaii. The data for chloride, sulfate, iron, alkalinity, arsenic, and methane appear to show that the dialysis samplers are capable of accurately collecting a passive sample for these constituents. In general, the comparisons of volatile organic compound concentrations showed a relatively close correspondence between the two different types of diffusion samples and between the diffusion samples and the low-flow samples collected in most wells. Divergence appears to have resulted primarily from the pumping method, either producing a mixed sample or water not characteristic of aquifer water moving through the borehole under ambient conditions. The fact that alkalinity was not detected in the passive diffusion bag samplers, highly alkaline waters without volatilization loss from effervescence, which can occur when a sample is acidified for preservation. Both dialysis and passive diffusion bag samplers are relatively inexpensive and can be deployed rapidly and easily. Passive diffusion bag samplers are intended for sampling volatile organic compounds only, but dialysis samplers can be used to sample both volatile organic compounds and inorganic solutes. Regenerated cellulose dialysis samplers, however, are subject to biodegradation and probably should be deployed no sooner than 2 weeks prior to recovery. 1 U.S. Geological Survey, Columbia, South Carolina. 2 Air Florce Center for Environmental Excellence, San Antionio, Texas.

  12. Field tests of diffusion samplers for inorganic constituents in wells and at a ground-water discharge zone

    USGS Publications Warehouse

    Vroblesky, Don A.; Petkewich, Matthew D.; Campbell, Ted R.

    2002-01-01

    Field tests were performed on two types of diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. Nylon-screen samplers and dialysis samplers were tested for the collection of arsenic, calcium, chloride, iron, manganese, sulfate, and dissolved oxygen. The investigations were conducted at the Naval Industrial Reserve Ordnance Plant (NIROP), Fridley, Minnesota, and at the Naval Air Station Fort Worth Joint Reserve Base (NAS Fort Worth JRB), Texas. Data indicate that, in general, nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water that correspond to concentrations obtained by low-flow sampling. Diffusion samplers offer a potentially time-saving approach to well sampling. Particular care must be taken, however, when sampling for iron and other metals, because of the potential for iron precipitation by oxygenation and when dealing with chemically stratified sampling intervals. Simple nylon-screen jar samplers buried beneath creekbed sediment appear to be effective tools for locating discharge zones of arsenic contaminated ground water. Although the LDPE samplers have proven to be inexpensive and simple to use in wells, they are limited by their inability to provide a representative sample of ionic solutes. The success of nylon-screen samplers in sediment studies suggests that these simple samplers may be useful for collecting water samples for inorganic constituents in wells. Results using dialysis bags deployed in wells suggest that these types of samplers have the potential to provide a representative sample of both VOCs and ionic solutes from ground water (Kaplan and others, 1991; Theodore A. Ehlke, U.S. Geological Survey, written commun., 2001). The purpose of this report is to provide results of field tests investigating the potential to use diffusion samplers to collect

  13. Systematic biases in measured PM10 values with U.S. Environmental Protection Agency-approved samplers at Owens Lake, California.

    PubMed

    Ono, D M; Hardebeck, E; Parker, J; Cox, B G

    2000-07-01

    From 1993 through 1998, Wedding or Graseby high-volume PM10 samplers were collocated with tapered element oscillating microbalance (TEOM) samplers at three sites at Owens Lake, CA. The study area is heavily impacted by windblown dust from the dry Owens Lake bed, which was exposed as a result of water diversions to the city of Los Angeles. A dichotomous (dichot) sampler and three collocated Partisol samplers were added in 1995 and 1999, respectively. U.S. Environmental Protection Agency (EPA) operating procedures were followed for all samplers, except for a Wedding sampler that was not cleaned for the purpose of this study. On average, the TEOM and Partisol samplers agreed to within 6%, and the dichot, Graseby, and Wedding samplers measured lower PM10 concentrations by about 10, 25, and 35%, respectively. Surprisingly, the "clean" Wedding sampler consistently measured the same concentration as the "dirty" Wedding sampler through 85 runs without cleaning. The finding that the Graseby and Wedding high-volume PM10 samplers read consistently lower than the TEOM, Partisol, and dichot samplers at Owens Lake is consistent with PM10 sampler comparisons done in other fugitive dust areas, and with wind tunnel tests showing that sampler cut points can be significantly lower than 10 microns under certain conditions. However, these results are opposite of the bias found for TEOM samplers in areas that have significant amounts of volatile particles, where the TEOM reads low due to the vaporization of particles on the TEOM's heated filter. Coarse particles like fugitive dust are relatively unaffected by the filter temperature. This study shows that in the absence of volatile particles and in the presence of fugitive dust, a different systematic bias of up to 35% exists between samplers using dichot inlets and high-volume samplers, which may cause the Graseby and Wedding PM10 samplers to undermeasure PM10 by up to 35% when the PM10 is predominantly from coarse particulate sources

  14. Field evaluation of portable and central site PM samplers emphasizing additive and differential mass concentration estimates

    NASA Astrophysics Data System (ADS)

    Chen, Fu-Lin; Vanderpool, Robert; Williams, Ronald; Dimmick, Fred; Grover, Brett D.; Long, Russell; Murdoch, Robert

    2011-08-01

    The US Environmental Protection Agency (EPA) published a National Ambient Air Quality Standard (NAAQS) and the accompanying Federal Reference Method (FRM) for PM 10 in 1987. The EPA revised the particle standards and FRM in 1997 to include PM 2.5. In 2005, EPA proposed revisions to this NAAQS to include PM 10-2.5 but only finalized revisions with a PM 2.5 FRM and the development of a national monitoring network in 2006. Presently, no EPA designated reference or equivalent method sampler has the ability to directly measure the mass concentrations of PM 10, PM 10-2.5, and PM 2.5 simultaneously. An additive approach has been used for samplers like the dichotomous monitors to calculate PM 10 mass concentrations from independent measures of PM 10-2.5 and PM 2.5 (i.e. PM 10 = PM 10-2.5 + PM 2.5). A differential approach has been used to calculate PM 10-2.5 from identical collocated PM 10 and PM 2.5 samplers (i.e. PM 10-2.5 = PM 10-PM 2.5). Since these two approaches have been used widely for PM measurements, it is informative to evaluate their precision and comparability. EPA performed collocated tests of five different particle samplers in the Research Triangle Park area of North Carolina to evaluate the comparability and to characterize the additive and differential approaches used to determine particle mass concentrations. The intra-sampler precision of MiniVol, Omni, and dichotomous samplers was less than 8.4%. The precision of PM 10 measurements using the additive approach with dichotomous samplers was less than 3.5%. The poorest precision of the various PM 10-2.5 differential approaches was less than 15.1%. No zero or negative PM 10-2.5 concentrations were calculated using the differential approach. A coefficient of determination of 0.81 or higher was obtained for all paired comparison of PM 10-2.5. The reported test results show that concentrations calculated from both the additive and differential approaches generally agree among the portable samplers, the more

  15. Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers

    USGS Publications Warehouse

    Alvarez, D.A.; Cranor, W.L.; Perkins, S.D.; Clark, R.C.; Smith, S.B.

    2008-01-01

    Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  16. A multisection passive sampler for measuring sediment porewater profile of dichlorodiphenyltrichloroethane and its metabolites.

    PubMed

    Liu, Hui-Hui; Bao, Lian-Jun; Feng, Wei-Hao; Xu, Shi-Ping; Wu, Feng-Chang; Zeng, Eddy Y

    2013-08-01

    In situ measurements of hydrophobic organic chemicals in sediment porewater, a central component in assessing the bioavailability and mobility of chemicals in sediment, have been scarce. Here, we introduce a multisection passive sampler with low-density polyethylene (LDPE) as the sorbent phase, which is appropriate for measuring vertical concentration profiles of chemicals in sediment porewater. This sampler is composed of a series of identical sampling cells insulated with seclusion rings. In each section, sorption of chemicals into LDPE is diffusion-controlled through the water layer separated from the sediment by a glass fiber filtration membrane and a porous stainless steel shield. Pilot laboratory testing indicated that the sampler can roughly determine the porewater concentrations of 1,1-dichloro-2,2-bis-(chlorophenyl)ethane (p,p'-DDD) and 1,1-dichloro-2,2-bis-(chlorophenyl)ethylene (p,p'-DDE), comparable to those yielded through centrifugation/liquid-liquid extraction, a conventional technique for sampling sediment porewater. Field deployment of the sampler was performed in an urbanized coastal region to measure the depth profiles of dichlorodiphenyltrichloroethane and its metabolites in sediment porewater. Sampling rate-calibrated and performance reference compound-calibrated concentrations were calculated, which were consistent with those obtained by the centrifugation/liquid-liquid extraction method. These results verified the utility of the sampler for measuring depth profiles of sediment porewater chemicals. PMID:23808846

  17. Monitoring of urban particulate using an electret-based passive sampler

    SciTech Connect

    Thorpe, A.; Hemingway, M.A.; Brown, R.C.

    1999-11-01

    Site sampling trials have been carried out in the urban environment in order to assess the usefulness of a passive sampling device, originally developed for personal monitoring of airborne dust levels in industry. The sampling element is a small disc of elect material (polymer carrying a permanent electric charge) within a metal frame weighing approximately 15 g. The sampler is designed to capture particles by electrostatic attraction, in which case the capture rate depends on their electrical mobility but is independent of the rate at which air flows past the device. Passive samplers, along with miniaturized cascade impactors, have been exposed to urban particulate for periods of up to 28 days in locations with significant different levels of airborne pollution. The cascade impactor data enabled good estimates to be made of PM{sub 10} and PMN{sub 2.5} levels, and data from the passive sampler correlated with the total dust sampled by the impactor and with both the size fractions, that with the PM{sub 10} being better. Too few data have yet been obtained for its accuracy to be established, but it is unlikely that it will approach that of pumped samplers. It has been shown to be potentially useful for multiple, simultaneous site sampling and for monitoring personal environmental exposure situations in which dispensing with a power source is particularly useful. Being small, the sampler is easy to hide or camouflage, and because it is cheap, its loss or damage is not a serious matter.

  18. Monitoring of urban particulate using an electret-based passive sampler.

    PubMed

    Thorpe, A; Hemingway, M A; Brown, R C

    1999-11-01

    Site sampling trials have been carried out in the urban environment in order to assess the usefulness of a passive sampling device, originally developed for personal monitoring of airborne dust levels in industry. The sampling element is a small disc of electret material (polymer carrying a permanent electric charge) within a metal frame weighing approximately 15 g. The sampler is designed to capture particles by electrostatic attraction, in which case the capture rate depends on their electrical mobility but is independent of the rate at which air flows past the device. Passive samplers, along with miniaturized cascade impactors, have been exposed to urban particulate for periods of up to 28 days in locations with significantly different levels of airborne pollution. The cascade impactor data enabled good estimates to be made of PM10 and PM2.5 levels, and data from the passive sampler correlated with the total dust sampled by the impactor and with both the size fractions, that with the PM10 being better. Too few data have yet been obtained for its accuracy to be established, but it is unlikely that it will approach that of pumped samplers. It has been shown to be potentially useful for multiple, simultaneous site sampling and for monitoring personal environmental exposure situations in which dispensing with a power source is particularly useful. Being small, the sampler is easy to hide or camouflage, and because it is cheap, its loss or damage is not a serious matter. PMID:10590548

  19. Construction and testing of a simple and economical soil greenhouse gas automatic sampler

    USGS Publications Warehouse

    Ginting, D.; Arnold, S.L.; Arnold, N.S.; Tubbs, R.S.

    2007-01-01

    Quantification of soil greenhouse gas emissions requires considerable sampling to account for spatial and/or temporal variation. With manual sampling, additional personnel are often not available to sample multiple sites within a narrow time interval. The objectives were to construct an automatic gas sampler and to compare the accuracy and precision of automatic versus manual sampling. The automatic sampler was tested with carbon dioxide (CO2) fluxes that mimicked the range of CO2 fluxes during a typical corn-growing season in eastern Nebraska. Gas samples were drawn from the chamber at 0, 5, and 10 min manually and with the automatic sampler. The three samples drawn with the automatic sampler were transferred to pre-vacuumed vials after 1 h; thus the samples in syringe barrels stayed connected with the increasing CO2 concentration in the chamber. The automatic sampler sustains accuracy and precision in greenhouse gas sampling while improving time efficiency and reducing labor stress. Copyright ?? Taylor & Francis Group, LLC.

  20. Enhanced semipermanent dialysis samplers for long-term environmental monitoring in saturated sediments.

    PubMed

    MacDonald, Luke H; Paull, Jeffery S; Jaffé, Peter R

    2013-05-01

    The ability to sample in situ natural environmental processes has proven to be challenging when working with redox-sensitive contaminates in saturated sediments in wetland systems, especially within the rhizosphere, where sharp redox gradients are common. Many traditional approaches are invasive and disturb natural sediment chemistry. Through laboratory and field studies, the work presented in this study demonstrates a novel semipermanent dialysis sampler that allows for long-term, anaerobic monitoring of shallow sediments. Dialysis samplers were deployed and tested for over 1 year while being exposed to extremes in climate. These newly designed devices produce statistically reproducible data and capture sensitive redox trends. Results from the newly designed samplers were compared to conventional samplers. Initially, both the new and old designs yielded statistically similar data, but these data diverged over a period of months. The new devices are less invasive, so data gathered from these devices are more likely to be a closer representation of true conditions in the subsurface. By giving reliable data from a consistent location in space, these new samplers represent a significant step forward in capturing spatial and temporal variability in wetland redox chemistry during long-term monitoring. PMID:22890868

  1. Field-emplaceable air samplers for automated ambient, site, and IAQ use (including TO-17 applications)

    SciTech Connect

    Padden, H.F.

    1996-12-31

    Air samples taken on collection media for laboratory analysis remain a highly sensitive and cost-effective means of assessment. However, collection of samples can be difficult using non-automated samplers, particularly over long terms or at remote locations. This paper describes a number of automated air samplers for sorbent-tube and filter use. The samplers are battery-powered, portable and weatherproof. They are suitable for: (1) Very rapid sampling of dual sorbent tubes for survey use. The sampler is very small and lightweight for ease of field use. (2) Sequential sampling of 24 tubes over a period up to 1 month. This technology is suitable for long-term ambient and superfund site monitoring. A meteorological station can be integrated. (3) Simultaneous sampling of 4 separate media at different flows during multiple events over a one month maximum period. This technology is useful for hazard identification and location. One application of interest to the environmental community is the use of a variant of the 24 tube sequential samplers by the United Nations for chemical weapon ban verification. 2 refs.

  2. Passive samplers accurately predict PAH levels in resident crayfish.

    PubMed

    Paulik, L Blair; Smith, Brian W; Bergmann, Alan J; Sower, Greg J; Forsberg, Norman D; Teeguarden, Justin G; Anderson, Kim A

    2016-02-15

    Contamination of resident aquatic organisms is a major concern for environmental risk assessors. However, collecting organisms to estimate risk is often prohibitively time and resource-intensive. Passive sampling accurately estimates resident organism contamination, and it saves time and resources. This study used low density polyethylene (LDPE) passive water samplers to predict polycyclic aromatic hydrocarbon (PAH) levels in signal crayfish, Pacifastacus leniusculus. Resident crayfish were collected at 5 sites within and outside of the Portland Harbor Superfund Megasite (PHSM) in the Willamette River in Portland, Oregon. LDPE deployment was spatially and temporally paired with crayfish collection. Crayfish visceral and tail tissue, as well as water-deployed LDPE, were extracted and analyzed for 62 PAHs using GC-MS/MS. Freely-dissolved concentrations (Cfree) of PAHs in water were calculated from concentrations in LDPE. Carcinogenic risks were estimated for all crayfish tissues, using benzo[a]pyrene equivalent concentrations (BaPeq). ∑PAH were 5-20 times higher in viscera than in tails, and ∑BaPeq were 6-70 times higher in viscera than in tails. Eating only tail tissue of crayfish would therefore significantly reduce carcinogenic risk compared to also eating viscera. Additionally, PAH levels in crayfish were compared to levels in crayfish collected 10 years earlier. PAH levels in crayfish were higher upriver of the PHSM and unchanged within the PHSM after the 10-year period. Finally, a linear regression model predicted levels of 34 PAHs in crayfish viscera with an associated R-squared value of 0.52 (and a correlation coefficient of 0.72), using only the Cfree PAHs in water. On average, the model predicted PAH concentrations in crayfish tissue within a factor of 2.4 ± 1.8 of measured concentrations. This affirms that passive water sampling accurately estimates PAH contamination in crayfish. Furthermore, the strong predictive ability of this simple model suggests

  3. The MAGIC Meteoric Smoke Particle Sampler - Description and Results

    NASA Astrophysics Data System (ADS)

    Hedin, J.

    2013-12-01

    properties is by direct collection followed by detailed laboratory analysis. However, the sounding rocket approach, which is the only practical method to carry out a sampling experiment at the desired mesospheric altitudes, is subject to critical limitations imposed by aerodynamics. As nanometer size particles tend to follow the airflow around the rocket payload structure, their sampling is a substantial experimental challenge. The objective of the MAGIC project (Mesospheric Aerosol - Genesis, Interaction and Composition) was to design and build an instrument to directly sample meteoric smoke particles in the mesosphere and return them to ground for detailed laboratory investigations. Here we describe the MAGIC meteoric smoke particle sampler and present attempts to directly sample MSPs and the challenges and uncertainties in the sampling procedure.

  4. Characterization of sampling artifacts in the measurement of carbonaceous particles using high- and low-volume samplers in Daejeon, Korea

    NASA Astrophysics Data System (ADS)

    Kim, Doyeon; Jung, Jinsang; Lee, Hyoeun; Choi, Seong-Ho; Lee, Sangil; Oh, Sanghyub

    2016-08-01

    This study investigates the influence of positive sampling artifacts on the determination of atmospheric organic carbon (OC) and elemental carbon (EC) by undenuded high-volume (HV) and low-volume (LV) samplers. The samples, which were collected in Daejeon, Korea during the spring and fall of 2014, were analyzed for OC and EC using a thermal optical transmittance (TOT) technique. Positive artifacts for OC using the undenuded LV and HV samplers were determined to be ∼12.2% and ∼7.2%, respectively. The adsorption of organic vapors on quartz filters and the analytical artifacts of thermal-optical method contributed equally to the positive artifact for the HV sampler, whereas that of the undenuded LV sampler was caused primarily by the adsorption of organic vapors on quartz filters with a relatively small contribution from the analytical artifacts of thermal-optical method. The analytical artifacts of thermal-optical method was closely related to the additional formation of pyrolyzed OC (POC) during the analysis, resulting in an underestimation of EC (HV sampler: 15.6 ± 15.6%; undenuded LV sampler: 9.1 ± 7.6%). The POC that formed during the analysis was related to the adsorption of organic vapors (in both the HV and undenuded LV samplers) and high particle loading on the quartz filters (HV sampler only). OC concentrations determined using the undenuded LV sampler and corrected using backup filter measurements correlated well with those of the denuded LV sampler (R2 = 0.98), suggesting that the backup filter correction method can be applied to particulate OC measurements using an undenuded LV sampler under conditions typical of those in Daejeon, Korea.

  5. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF EXPOSURE MEDIA (PUFS AND QUARTZ FIBER FILTERS) FOR AIR SAMPLERS FOR PESTICIDE AND PAH COLLECTION (L09)

    EPA Science Inventory

    This procedure describes preparation and disassembly of polyurethane foam (PUF) samplers, preparation and cleaning of filters and PUF plugs, assembly and packaging of samplers, and disassembly of exposed samplers and handling of exposed plugs and filters. Keywords: air; pestici...

  6. Bayesian Analysis for Exponential Random Graph Models Using the Adaptive Exchange Sampler*

    PubMed Central

    Jin, Ick Hoon; Yuan, Ying; Liang, Faming

    2014-01-01

    Exponential random graph models have been widely used in social network analysis. However, these models are extremely difficult to handle from a statistical viewpoint, because of the intractable normalizing constant and model degeneracy. In this paper, we consider a fully Bayesian analysis for exponential random graph models using the adaptive exchange sampler, which solves the intractable normalizing constant and model degeneracy issues encountered in Markov chain Monte Carlo (MCMC) simulations. The adaptive exchange sampler can be viewed as a MCMC extension of the exchange algorithm, and it generates auxiliary networks via an importance sampling procedure from an auxiliary Markov chain running in parallel. The convergence of this algorithm is established under mild conditions. The adaptive exchange sampler is illustrated using a few social networks, including the Florentine business network, molecule synthetic network, and dolphins network. The results indicate that the adaptive exchange algorithm can produce more accurate estimates than approximate exchange algorithms, while maintaining the same computational efficiency. PMID:24653788

  7. A rapid leaf-disc sampler for psychrometric water potential measurements.

    PubMed

    Wullschleger, S D; Oosterhuis, D M

    1986-06-01

    An instrument was designed which facilitates faster and more accurate sampling of leaf discs for psychrometric water potential measurements. The instrument consists of an aluminum housing, a spring-loaded plunger, and a modified brass-plated cork borer. The leaf-disc sampler was compared with the conventional method of sampling discs for measurement of leaf water potential with thermocouple psychrometers on a range of plant material including Gossypium hirsutum L., Zea mays L., and Begonia rex-cultorum L. The new sampler permitted a leaf disc to be excised and inserted into the psychrometer sample chamber in less than 7 seconds, which was more than twice as fast as the conventional method. This resulted in more accurate determinations of leaf water potential due to reduced evaporative water losses. The leaf-disc sampler also significantly reduced sample variability between individual measurements. This instrument can be used for many other laboratory and field measurements that necessitate leaf disc sampling. PMID:16664879

  8. Design of an air sampler for a small unmanned aerial vehicle.

    PubMed

    Peräjärvi, K; Lehtinen, J; Pöllänen, R; Toivonen, H

    2008-01-01

    In the aftermath of a nuclear accident or malevolent act, it is of paramount importance to have the capability to monitor airborne radioactive substances by collecting air samples. For potentially dangerous missions, the Radiation and Nuclear Safety Authority of Finland (STUK) has developed an air sampler to be used on a small unmanned aerial vehicle. When a Petrianov or Fluoropore filter is used in the sampler and the air velocity is 71 km h(-1), the air flow rate through the filter is 0.73 m(3) h(-1) or 0.23 m(3) h(-1), respectively. The present article introduces the developed air sampler using fluid dynamic simulations and wind tunnel data. The operation of the system was validated by collecting airborne radioactive aerosols from air. PMID:19091809

  9. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    SciTech Connect

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W. )

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  10. COMPARISON OF THE PARTICLE SIZE DISTRIBUTION OF HEAVY-DUTY DIESEL EXHAUST USING A DILUTION TAIL-PIPE SAMPLER AND IN-PLUME SAMPLER DURING ON-ROAD OPERATION

    EPA Science Inventory

    The paper compares the particle size distribution of heavy-duty diesel exhaust using a dilution tail-pipe sampler and an in-plume sampler during on-road operation. EPA's On-road Diesel Emissions Characterization Facility, modified to incorporate particle measurement instrumentat...

  11. Observational properties of simulated galaxies in overdense and average regions at redshifts z ≃ 6-12

    NASA Astrophysics Data System (ADS)

    Yajima, Hidenobu; Shlosman, Isaac; Romano-Díaz, Emilio; Nagamine, Kentaro

    2015-07-01

    We use high-resolution zoom-in cosmological simulations of galaxies of Romano-Díaz et al., post-processing them with a panchromatic three-dimensional radiation transfer code to obtain the galaxy UV luminosity function (LF) at z ≃ 6-12. The galaxies are followed in a rare, heavily overdense region within a ˜5σ density peak, which can host high-z quasars, and in an average density region, down to the stellar mass of Mstar ˜ 4 × 107 M⊙. We find that the overdense regions evolve at a substantially accelerated pace - the most massive galaxy has grown to Mstar ˜ 8.4 × 1010 M⊙ by z = 6.3, contains dust of Mdust ˜ 4.1 × 108 M⊙, and is associated with a very high star formation rate, SFR ˜ 745 M⊙ yr- 1. The attained SFR-Mstar correlation results in the specific SFR slowly increasing with Mstar. Most of the UV radiation in massive galaxies is absorbed by the dust, its escape fraction fesc is low, increasing slowly with time. Galaxies in the average region have less dust, and agree with the observed UV LF. The LF of the overdense region is substantially higher, and contains much brighter galaxies. The massive galaxies are bright in the infrared (IR) due to the dust thermal emission, with LIR ˜ 3.7 × 1012 L⊙ at z = 6.3, while LIR < 1011 L⊙ for the low-mass galaxies. Therefore, ALMA can probe massive galaxies in the overdense region up to z ˜ 10 with a reasonable integration time. The UV spectral properties of discy galaxies depend significantly upon the viewing angle. The stellar and dust masses of the most massive galaxy in the overdense region are comparable to those of the sub-millimetre galaxy found by Riechers et al. at z = 6.3, while the modelled SFR and the sub-millimetre flux fall slightly below the observed one. Statistical significance of these similarities and differences will only become clear with the upcoming ALMA observations.

  12. Composite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface

    PubMed Central

    Tufts, Jenia A. M.; Meyer, Kathryn M.; Calfee, Michael Worth; Lee, Sang Don

    2014-01-01

    A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas), larger than the 645 cm2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p  =  0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p  =  0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times. PMID:25470365

  13. Multiple tube sampler for benthic and pelagic invertebrates in shallow wetlands

    USGS Publications Warehouse

    Euliss, N.H., Jr.; Swanson, G.A.; MacKay, J.

    1992-01-01

    Sampling devices that minimize bias and function in aquatic habitats used by waterfowl are needed. We devised a multiple tube sampling device for quantitative sampling of small (<3 cm) aquatic invertebrates in wetlands. The sampler reduced bias associated with sampling macroinvertebrates that utilize the benthic-pelagic interface because it simultaneously collects benthic and water column invertebrates. The sampler was statistically superior to other sampling devices because each sampling effort provided 4 subsamples and a within-sample variance that could be estimated. The device also was durable and reasonably inexpensive to construct.

  14. A sampler for quantifying the vertical distribution of macroinvertebrates in shallow wetlands

    USGS Publications Warehouse

    MacKay, J.; Euliss, N.H., Jr.

    1993-01-01

    A sampler for quantifying the vertical distribution of aquatic macroinvertebrates in wetlands is described. This device will facilitate quantitative sampling of macroinvertebrates in waterfowl ecology and related studies. Because it simultaneously collects benthic and pelagic invertebrates the sampler reduces bias associated with sampling macroinvertebrates that occupy the benthic-pelagic interface of wetlands. The sampling device also separates benthic and pelagic macroinvertebrates into separate vertical profiles to facilitate studies of distribution patterns or the influence of chemical and physical gradients on invertebrate vertical distribution.

  15. Passive capillary sampler for measuring soil water drainage and flux in the vadose zone: Design, performance and enhancement

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Various soil water samplers are used to monitor, measure and estimate drainage water, fluxes and solute transport in the soil vadose zone. Passive capillary samplers (PCAPs) have shown potential to provide better measurements and estimates of soil water drainage and fluxes than other lysimeters and ...

  16. VALIDATION OF OGAWA PASSIVE SAMPLERS FOR THE DETERMINATION OF GASEOUS AMMONIA CONCENTRATIONS IN AGRICULTURAL SETTINGS. (R826945)

    EPA Science Inventory

    The Ogawa passive sampler (Ogawa USA, Pompano Beach, Florida) is a useful tool for monitoring atmospheric ammonia (NH3(g)) concentrations and assessing the effects of agricultural waste management practices on NH3(g) emissions. The Ogawa sampler, with fil...

  17. DEVELOPMENT AND TESTING OF A WHOLE-AIR SAMPLER FOR MEASUREMENT OF PERSONAL EXPOSURE TO VOLATILE ORGANIC COMPOUNDS

    EPA Science Inventory

    A small and relatively lightweight (3.35 kg) whole-air (canister) sampler that can be worn to monitor personal exposures to volatile organic compounds was developed and evaluated. The prototype personal whole air sampler (PWAS) consists of a 1-L canister, a mass flow controller, ...

  18. DEVELOPMENT AND EVALUATION OF A HIGH-VOLUME DICHOTOMOUS SAMPLER FOR CHEMICAL SPECIATION OF COARSE AND FINE PARTICLES

    EPA Science Inventory

    This paper describes the development and field evaluation of a compact high-volume dichotomous sampler (HVDS) that collects coarse (PM10-2.5) and fine (PM2.5) particulate matter. In its primary configuration as tested, the sampler size-fractionates PM10 into...

  19. PERFORMANCE INVESTIGATION OF THE MANNING MODEL S-4000 PORTABLE WASTEWATER SAMPLER AND THE MODEL F-3000 DIPPER FLOWMETER

    EPA Science Inventory

    Performance of the Manning model S-4000 wastewater sampler and the model F-3000 flowmeter was investigated. The S-4000 wastewater sampler was tested at temperatures of 2, 20, and 35C to determine accuracy and precision of the timer and sample volumes. The multiplexer function of ...

  20. Model stream channel testing of a UV-transparent polymer-based passive sampler for ultra-low-cost water screening applications

    EPA Science Inventory

    Passive samplers are increasingly being considered for analyses of waters for screening applications, to monitor for the presence of unwanted chemical compounds. Passive samplers typically work by accumulating and concentrating chemicals from the surrounding water over time, all...

  1. Thoracic size-selective sampling of fibres: performance of four types of thoracic sampler in laboratory tests.

    PubMed

    Jones, A D; Aitken, R J; Fabriès, J F; Kauffer, E; Liden, G; Maynard, A; Riediger, G; Sahle, W

    2005-08-01

    The counting of fibres on membrane filters could be facilitated by using size-selective samplers to exclude coarse particulate and fibres that impede fibre counting. Furthermore, the use of thoracic size selection would also remove the present requirement to discriminate fibres by diameter during counting. However, before thoracic samplers become acceptable for sampling fibres, their performance with fibres needs to be determined. This study examines the performance of four thoracic samplers: the GK2.69 cyclone, a Modified SIMPEDS cyclone, the CATHIA sampler (inertial separation) and the IOM thoracic sampler (porous foam pre-selector). The uniformity of sample deposit on the filter samples, which is important when counts are taken on random fields, was examined with two sizes of spherical particles (1 and 10 microm) and a glass fibre aerosol with fibres spanning the aerodynamic size range of the thoracic convention. Counts by optical microscopy examined fields on a set scanning pattern. Hotspots of deposition were detected for one of the thoracic samplers (Modified SIMPEDS with the 10 microm particles and the fibres). These hotspots were attributed to the inertial flow pattern near the port from the cyclone pre-separator. For the other three thoracic samplers, the distribution was similar to that on a cowled sampler, the current standard sampler for fibres. Aerodynamic selection was examined by comparing fibre concentration on thoracic samples with those measured on semi-isokinetic samples, using fibre size (and hence calculated aerodynamic diameter) and number data obtained by scanning electron microscope evaluation in four laboratories. The size-selection characteristics of three thoracic samplers (GK2.69, Modified SIMPEDS and CATHIA) appeared very similar to the thoracic convention; there was a slight oversampling (relative to the convention) for d(ae) < 7 microm, but that would not be disadvantageous for comparability with the cowled sampler. Only the IOM

  2. Teacher's Guide to Resources of the Oklahoma Historical Society, Keyed to the Priority Academic Student Skills (PASS), Grades 6-12 Oklahoma History.

    ERIC Educational Resources Information Center

    National Diffusion Network (DHEW/OE), Washington, DC.

    This guide is correlated to the PASS (Priority Academic Student Skills) objectives for Oklahoma history in grades 6-12. The guide was developed to aid in the teaching of the PASS objectives by identifying primary sources, audiovisual materials, field trips and scholarly materials that relate to each objective. The guide is divided into seven…

  3. Validity and Reliability Study of the Self-Efficacy Scale in Rendering Piano Education to Children of 6-12 Years

    ERIC Educational Resources Information Center

    Ekinci, Hatice

    2014-01-01

    This study was conducted in order to develop a valid and reliable scale that can be used in measuring self-efficacy of candidate music teachers in rendering piano education to children of 6-12 years. To this end, a pool of 51 items was created by using the literature, and taking the opinions of piano professors and piano instructors working with…

  4. Continuous-flow water sampler for real-time isotopic water measurements

    NASA Astrophysics Data System (ADS)

    Carter, J.; Dennis, K.

    2013-12-01

    Measuring the stable isotopes of liquid water (δ18O and δD) is a tool familiar to many Earth scientists, but most current techniques require discrete sampling. For example, isotope ratio mass spectrometry requires the collection of aliquots of water that are then converted to CO2, CO or H2 for analysis. Similarly, laser-based techniques, such as Cavity Ring-Down Spectroscopy (CRDS) convert discrete samples (typically < 2μL) of liquid water to water vapor using a flash vaporization process. By requiring the use of discrete samples fine-scale spatial and temporal studies of changes in δ18O and δD are limited. Here we present a continuous-flow water sampler that will enable scientists to probe isotopic changes in real-time, with applications including, but not limited to, quantification of the 'amount effect' (Dansgaard, 1964) during an individual precipitation event or storm track, real-time mixing of water in river systems, and shipboard continuous water measurements (Munksgaard et al., 2012). Due to the inherent ability of CRDS to measure a continuous flow of water vapor it is an ideal candidate for interfacing with a continuous water sampling system. Here we present results from the first commercially available continuous-flow water sampler, developed by engineers at Picarro. This peripheral device is compatible with Picarro CRDS isotopic water analyzers, allowing real-time, continuous isotopic measurements of liquid water. The new device, which expands upon the design of Munskgaard et al. (2011), utilizes expanded polytetrafluoroethylene (ePTFE) membrane technology to continuously generate gas-phase water, while liquid water is pumped through the system. The water vapor subsequently travels to the CRDS analyzer where the isotopic ratios are measured and recorded. The generation of water vapor using membrane technology is sensitive to environmental conditions, which if not actively control, lead to sustainable experimental noise and drift. Consequently, our

  5. Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs)

    NASA Astrophysics Data System (ADS)

    Bartkow, Michael E.; Huckins, James N.; Müller, Jochen F.

    2004-11-01

    Semipermeable membrane devices (SPMDs) have been used as passive air samplers of semivolatile organic compounds in a range of studies. However, due to a lack of calibration data for polyaromatic hydrocarbons (PAHs), SPMD data have not been used to estimate air concentrations of target PAHs. In this study, SPMDs were deployed for 32 days at two sites in a major metropolitan area in Australia. High-volume active sampling systems (HiVol) were co-deployed at both sites. Using the HiVol air concentration data from one site, SPMD sampling rates were measured for 12 US EPA Priority Pollutant PAHs and then these values were used to determine air concentrations at the second site from SPMD concentrations. Air concentrations were also measured at the second site with co-deployed HiVols to validate the SPMD results. PAHs mostly associated with the vapour phase (Fluorene to Pyrene) dominated both the HiVol and passive air samples. Reproducibility between replicate passive samplers was satisfactory (CV<20%) for the majority of compounds. Sampling rates ranged between 0.6 and 6.1 m3 d-1. SPMD-based air concentrations were calculated at the second site for each compound using these sampling rates and the differences between SPMD-derived air concentrations and those measured using a HiVol were, on average, within a factor of 1.5. The dominant processes for the uptake of PAHs by SPMDs were also assessed. Using the SPMD method described herein, estimates of particulate sorbed airborne PAHs with five rings or greater were within 1.8-fold of HiVol measured values.

  6. Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs)

    USGS Publications Warehouse

    Bartkow, M.E.; Huckins, J.N.; Muller, J.F.

    2004-01-01

    Semipermeable membrane devices (SPMDs) have been used as passive air samplers of semivolatile organic compounds in a range of studies. However, due to a lack of calibration data for polyaromatic hydrocarbons (PAHs), SPMD data have not been used to estimate air concentrations of target PAHs. In this study, SPMDs were deployed for 32 days at two sites in a major metropolitan area in Australia. High-volume active sampling systems (HiVol) were co-deployed at both sites. Using the HiVol air concentration data from one site, SPMD sampling rates were measured for 12 US EPA Priority Pollutant PAHs and then these values were used to determine air concentrations at the second site from SPMD concentrations. Air concentrations were also measured at the second site with co-deployed HiVols to validate the SPMD results. PAHs mostly associated with the vapour phase (Fluorene to Pyrene) dominated both the HiVol and passive air samples. Reproducibility between replicate passive samplers was satisfactory (CV<20%) for the majority of compounds. Sampling rates ranged between 0.6 and 6.1 m3 d-1. SPMD-based air concentrations were calculated at the second site for each compound using these sampling rates and the differences between SPMD-derived air concentrations and those measured using a HiVol were, on average, within a factor of 1.5. The dominant processes for the uptake of PAHs by SPMDs were also assessed. Using the SPMD method described herein, estimates of particulate sorbed airborne PAHs with five rings or greater were within 1.8-fold of HiVol measured values. ?? 2004 Elsevier Ltd. All rights reserved.

  7. Concentration of Methylamine and Ethylamine Salts measured by a particle into liquid sampler and Ion Chromatography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A Particle-Into-Liquid Sampler (PILS) and ion chromatographs (ICs) were used to detect the concentration of methylamine salts associated with atmospheric particulate matter reactions in a smog chamber. The smog chamber is located at U.C. Riverside’s College of Engineering Center for Environmental Re...

  8. Laboratory data on coarse-sediment transport for bedload-sampler calibrations

    USGS Publications Warehouse

    Hubbell, David Wellington; Stevens, H.H., Jr.; Skinner, J.V.; Beverage, J.P.

    1987-01-01

    A unique facility capable of recirculating and continuously measuring the transport rates of sediment particles ranging in size from about 1 to 75 millimeters in diameter was designed and used in an extensive program involving the calibration of bedload samplers. The facility consisted of a 9-footwide by 6-foot-deep by 272-foot-long rectangular channel that incorporated seven automated collection pans and a sedimentreturn system. The collection pans accumulated, weighed, and periodically dumped bedload falling through a slot in the channel floor. Variations of the Helley-Smith bedload sampler, an Arnhem sampler, and two VUV-type samplers were used to obtain transport rates for comparison with rates measured at the bedload slot (trap). Tests were conducted under 20 different hydraulic and sedimentologic conditions (runs) with 3 uniform-size bed materials and a bed-material mixture. Hydraulic and sedimentologic data collected concurrently with the calibration measurements are described and, in part, summarized in tabular and graphic form. Tables indicate the extent of the data, which are available on magnetic media. The information includes sediment-transport rates; particle-size distributions; water discharges, depths, and slopes; longitudinal profiles of streambed-surface elevations; and temporal records of streambed-surface elevations at fixed locations.

  9. Performance of Passive Samplers for Monitoring Estuarine Water Column Concentrations 1. Contaminants of Concern

    PubMed Central

    Perron, Monique M.; Burgess, Robert M.; Suuberg, Eric M.; Cantwell, Mark G.; Pennell, Kelly G.

    2014-01-01

    Contaminants enter marine and estuarine environments and pose a risk to human and ecological health. Recently, passive sampling devices have been utilized to estimate dissolved concentrations of COCs, such as polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). In the present study, the performance of three common passive samplers was evaluated for sampling PAHs and PCBs at several stations in the temperate estuary Narragansett Bay (Rhode Island, USA). Sampler polymers included polyethylene (PE), polydimethylsiloxane (PDMS) coated solid phase microextraction (SPME) fibers, and polyoxymethylene (POM). Dissolved concentrations of each contaminant were calculated using measured sampler concentrations adjusted for equilibrium conditions with performance reference compounds (PRCs) and chemical-specific partition coefficients derived in the laboratory. Despite differences in PE and POM sampler concentrations, calculated total dissolved concentrations ranged from 14–93 ng/L and 13–465 pg/L for PAHs and PCBs, respectively. Dissolved concentrations of PAHs were approximately three times greater based on POM compared to PE while dissolved concentrations of PCBs based on PE were approximately three times greater than POM. Concentrations in SPME were not reported due to the lack of detectable chemical in the amount of PDMS polymer deployed. Continued research is needed to improve and support PE and POM use for the routine monitoring of COCs. For example, a better understanding of the use of PRCs with POM is critically needed. PMID:23832638

  10. EVALUATION OF PORTABLE MULTISORBEN AIR SAMPLERS FOR USE WITH AN AUTOMATED MULTITUDE ANALYZER

    EPA Science Inventory

    The objective of this study was to evaluate the operational characteristics of the Perkin-Elmer Model STS 25 Sequential Tube Sampler and IITRI/IIT (IIT Research Institute/Illinois Institute of Technology) Total Isolated-by-Microenvironment Exposure (TIME) monitor. Both units use ...

  11. FABRICATION, OPTIMIZATION, AND EVALUATION OF A MASSIVE VOLUME AIR SAMPLER OF SIZED RESPIRABLE PARTICULATE MATTER

    EPA Science Inventory

    A prototype sampler which collects airborne particulate matter in three stages, 3.5 micrometers, 1.7 micrometers, and below 1.7 micrometers (the cutoffs of which closely fit the ACGIH respirable size curve) was constructed previously. Component failures and operational difficulti...

  12. Framing the Problem of Identity in Composition and TESOL Studies: A Sampler

    ERIC Educational Resources Information Center

    Messekher, Hayat

    2011-01-01

    This article looks at how the intricate issue of identity has been addressed and framed in composition and TESOL studies (C&T). It reviews five articles and a book as a sampler to explore identity research in various contexts ranging from the problematic rise of identity in second-language acquisition (SLA) research in 1997, which represented a…

  13. A Passive Sampler for Determination of Nitrogen Dioxide in Ambient Air

    ERIC Educational Resources Information Center

    Xiao, Dan; Lin, Lianzhi; Yuan, Hongyan; Choi, Martin M. F.; Chan, Winghong

    2005-01-01

    A passive sampler that provides a convenient, simple, and fast method for nitrogen dioxide determination is proposed. The experiment can be modified for determinations of other air pollutants like formaldehyde and sulfur dioxide for hands-on experience for students studying environmental pollution problems.

  14. PASSIVE AEROSOL SAMPLER FOR CHARACTERIZATION, AMBIENT CONCENTRATION, AND PARTICLE SIZE MEASUREMENT

    EPA Science Inventory

    This is an extended abstract of a presentation made at the Air and Waste Management Association's Symposium on Air Quality Measurement Methods and Technology, Durham, NC, May 9-11, 2006. The abstract describes the theory, design, and initial testing of a passive aerosol sampler f...

  15. 7 CFR 52.34 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false How samples are drawn by inspectors or licensed... Sampling § 52.34 How samples are drawn by inspectors or licensed samplers. An inspector or a licensed... regulations in this part, as to secure a representative sample of the lot. Samples drawn for inspection...

  16. METHODS INTERCOMPARISON OF SAMPLERS FOR EPA'S NATIONAL PM 2.5 CHEMICAL SPECIATION NETWORK

    EPA Science Inventory

    The objective of this sampler intercomparison field study is to determine the performance characteristics for the collection of the chemical components of PM2.5 by the chemical speciation monitors developed for the national PM2.5 network relative to each other, to the Federal R...

  17. PM 2.5 CHEMICAL SPECIATION SAMPLER EVALUATION FIELD PROGRAM: RESULTS FROM THE FOUR CITY STUDY

    EPA Science Inventory

    The objective of this sampler intercomparison field study is to determine the performance characteristics for the collection of the chemical components of PM2.5 by the chemical speciation monitors developed for the national network relative to each other, to the Federal Referen...

  18. 7 CFR 800.185 - Duties of official personnel and warehouse samplers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Duties of official personnel and warehouse samplers. 800.185 Section 800.185 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Duties and Conduct...

  19. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... under these regulations complies with the applicable permissibility provisions of 30 CFR 18.68. ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...

  20. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... under these regulations complies with the applicable permissibility provisions of 30 CFR 18.68. ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...

  1. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... under these regulations complies with the applicable permissibility provisions of 30 CFR 18.68. ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...

  2. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... under these regulations complies with the applicable permissibility provisions of 30 CFR 18.68. ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR...

  3. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... specified in 40 CFR part 50, appendix L or appendix O, as applicable. The test requirements and performance... specified for a reference method sampler in 40 CFR part 50, appendix L or appendix O, as applicable, such as... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Aerosol transport test for Class...

  4. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... specified in 40 CFR part 50, appendix L or appendix O, as applicable. The test requirements and performance... specified for a reference method sampler in 40 CFR part 50, appendix L or appendix O, as applicable, such as... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Aerosol transport test for Class...

  5. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... specified in 40 CFR part 50, appendix L or appendix O, as applicable. The test requirements and performance... specified for a reference method sampler in 40 CFR part 50, appendix L or appendix O, as applicable, such as... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Aerosol transport test for Class...

  6. Efficacy of passive capillary samplers for estimating soil water drainage in the vadose zone

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The efficacy and accuracy of PCAP samplers were evaluated for continuous estimating of soil water drainage and fluxes below the rootzone of a sugarbeet-potato-barley rotation under two irrigation frequencies. Twelve automated PCAPs with outside sampling surface dimensions of 91 cm length x 31 cm wid...

  7. AUTOMATED SYSTEM FOR COLLECTING MULTIPLE, SEQUENTIAL SAMPLES FROM SOIL WATER SAMPLERS UNDER CONTINUOUS VACUUM

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Manually collecting a series of sequential, discrete water samples from soil water percolation samplers, or similar devices, that withdraw water from unsaturated porous media under continuous vacuum is a logistical challenge, though the resulting collection can provide valuable information on the dy...

  8. Clarendon Alternative School. Japanese Bilingual Bicultural Program. Curriculum Sampler II: Science.

    ERIC Educational Resources Information Center

    Choy, V. Kanani, Ed.; And Others

    A sampler of thematic science lessons from the Japanese bilingual/bicultural education program of the Clarendon Alternative School, a California elementary school, is presented. The lessons are designed to integrate Japanese instruction with the core science curriculum. Each lesson contains this information: the grade level, teacher(s), and…

  9. 7 CFR 52.32 - Suspension or revocation of license of licensed sampler or licensed inspector.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Suspension or revocation of license of licensed... Inspection and Certification Licensing of Samplers and Inspectors § 52.32 Suspension or revocation of license..., with the Secretary supported by any argument or evidence that he may wish to offer as to why...

  10. Time profile analysis of photodetector signals in multi read-out calorimetry with GHz samplers

    NASA Astrophysics Data System (ADS)

    Bedeschi, F.; Bitossi, M.; Carosi, R.; Incagli, M.; Pegna, R.; Scuri, F.

    2009-04-01

    We present possible applications of DAQ systems based on Domino Ring Samplers (DRS) for time profile analysis of photodetector signals used for present and future multiple read-out calorimeters. The example of an 80-channel system in preparation for dual read-out calorimetry (DREAM) is described.

  11. 7 CFR 52.34 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false How samples are drawn by inspectors or licensed... Sampling § 52.34 How samples are drawn by inspectors or licensed samplers. An inspector or a licensed... regulations in this part, as to secure a representative sample of the lot. Samples drawn for inspection...

  12. 7 CFR 52.34 - How samples are drawn by inspectors or licensed samplers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false How samples are drawn by inspectors or licensed... Sampling § 52.34 How samples are drawn by inspectors or licensed samplers. An inspector or a licensed... regulations in this part, as to secure a representative sample of the lot. Samples drawn for inspection...

  13. Validation tests of a new high uptake rate passive sampler for nitrogen dioxide measurements.

    PubMed

    Piechocki-Minguy, A; Plaisance, H; Garcia-Fouqué, S; Galloo, J C; Guillermo, R

    2003-12-01

    This study explains the main characteristics of a new passive sampler which is able to give reliable nitrogen dioxide measurements for short time sampling. The sampling rate was found to be on average 0.89 cm3 s(-1) for indoor sampling and 1.00 cm3 s(-1) for outdoor sampling. The detection limit was evaluated at 11 microg m(-3) for a one-hour measurement. In field conditions, the passive sampler measurements were in agreement with those of the chemiluminescent NOx monitors. Measurement uncertainties were estimated at 34% and 38% for laboratory tests in conditions corresponding respectively to indoor and outdoor measurements and were evaluated at 28 to 37% depending on the nitrogen dioxide concentration for field experiments. The effects of various factors on the passive sampler were determined in an exposure chamber. The sampling rate of the retained sampler version was not significantly influenced by wind speeds superior to 0.3 m s(-1). A decrease of the uptake rate is observed for high nitrogen dioxide doses. The sampling rate increases linearly with temperature (2% per degree C). The relative humidity has only a weak effect. PMID:14977149

  14. EVALUATION OF AN S2 SAMPLER FOR RECEPTOR MODELING OF WOODSMOKE EMISSIONS

    EPA Science Inventory

    The Source Signature (squared S) sampler was developed to characterize the carbon (C) and elemental components in fine particulate emissions from a residential wood burner. The hot exhaust is sampled and diluted with filtered air to simulate normal diffusion. The resulting aeroso...

  15. COLLECTION EFFICIENCY OF THE HIGH VOLUME SMALL SURFACE SAMPLER ON WORN CARPETS

    EPA Science Inventory

    Collection Efficiency of the High Volume Small Surface Sampler on Worn Carpets

    Erik R. Svendsen*?, Peter S. Thorne*, Stephen J. Reynolds*?, Patrick T. O'Shaughnessy*, Alba Quinones*, Dale Zimmerman*, and Nervana Metwali*

    *University of Iowa College of Public Health<...

  16. EVALUATION OF IN SITU COSOLVENT FLUSHING DYNAMICS USING A NETWORK OF SPATIALLY DISTRIBUTED MULTILEVEL SAMPLERS

    EPA Science Inventory

    A network of multilevel samplers was used to evaluate the spatial patterns in containment extraction during an in situ cosolvent flushing field test. The study was conducted in an isolation test cell installed in a fuel contaminated site at Hill Air Force Base, Utah. Partitioni...

  17. Measurement of gaseous PAHs with an innovative passive sampler in community exposure studies

    EPA Science Inventory

    A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify gaseous polycyclic aromatic hydrocarbons (PAHs) in personal, indoor and outdoor air. A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from four 80 sections of 1 cm long SPB-5 GC c...

  18. PERFORMANCE OF A NEW DIFFUSIVE SAMPLER FOR HG0 DETERMINATION IN THE TROPOSPHERE

    EPA Science Inventory

    Mercury behaves uniquely in the atmosphere due to its volatility and long lifetime. The existing methods for measuring atmospheric mercury are either expensive or labour intensive. The present paper presents a new measurement technique, the diffusive sampler, that is portable, in...

  19. 7 CFR 52.30 - Application to become a licensed sampler.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... certified by him to be true, complete, and correct to the best of his knowledge and belief, and the application shall contain or be accompanied by: (a) A statement showing his present and previous occupations... previous to the date of his application; (b) A statement that, in his capacity as a licensed sampler,...

  20. 7 CFR 52.30 - Application to become a licensed sampler.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... certified by him to be true, complete, and correct to the best of his knowledge and belief, and the application shall contain or be accompanied by: (a) A statement showing his present and previous occupations... previous to the date of his application; (b) A statement that, in his capacity as a licensed sampler,...

  1. Spatial analysis of volatile organic compounds in South Philadelphia using passive samplers

    EPA Science Inventory

    Select volatile organic compounds (VOCs) were measured in the vicinity of a petroleum refinery and related operations in South Philadelphia, Pennsylvania, USA, using passive air sampling and laboratory analysis methods. Two-week, time-integrated samplers were deployed at 17 sites...

  2. Multispectral Resource Sampler: Proof of concept. Literature survey of bidirectional reflectance

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A bibliography compiled in order to give a comprehensive review of previous work in scene bidirectional reflectance, particularly those studies relevant to the Multispectral Resource Sampler (MRS) is presented. The bibliography contains 124 abstracts. In addition a synthesis of the literature results is given along with background information concerning MRS.

  3. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specified in 40 CFR part 50, appendix L or appendix O, as applicable. The test requirements and performance... specified for a reference method sampler in 40 CFR part 50, appendix L or appendix O, as applicable, such as...-traceability (if required) of all measurement instruments used in the tests. The accuracy of flow rate...

  4. 40 CFR 53.54 - Test for proper sampler operation following power interruptions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the AC line electrical power to the sampler 5 times, with durations of 20 seconds, 40 seconds, 2 minutes, 7 minutes, and 20 minutes (respectively), with not less than 10 minutes of normal electrical..., excluding the periods of electrical power interruption. Verify that the elapsed sample time reported by...

  5. 40 CFR 53.54 - Test for proper sampler operation following power interruptions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the AC line electrical power to the sampler 5 times, with durations of 20 seconds, 40 seconds, 2 minutes, 7 minutes, and 20 minutes (respectively), with not less than 10 minutes of normal electrical..., excluding the periods of electrical power interruption. Verify that the elapsed sample time reported by...

  6. 40 CFR 53.54 - Test for proper sampler operation following power interruptions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the AC line electrical power to the sampler 5 times, with durations of 20 seconds, 40 seconds, 2 minutes, 7 minutes, and 20 minutes (respectively), with not less than 10 minutes of normal electrical..., excluding the periods of electrical power interruption. Verify that the elapsed sample time reported by...

  7. 40 CFR 53.54 - Test for proper sampler operation following power interruptions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the AC line electrical power to the sampler 5 times, with durations of 20 seconds, 40 seconds, 2 minutes, 7 minutes, and 20 minutes (respectively), with not less than 10 minutes of normal electrical..., excluding the periods of electrical power interruption. Verify that the elapsed sample time reported by...

  8. EVALUATION OF MEMBRANE TYPE FOR USE IN DIFFUSION SAMPLERS TO MONITOR GROUND WATER QUALITY

    EPA Science Inventory

    The Discrete Multi-Level Sampler (DMLS®) system has proven to be a useful tool for obtaining discrete interval contaminant concentrations at hazardous waste sites. The DMLS® utilizes dialysis cells, which consist of a polypropylene vial, covered on both ends by a permeable membr...

  9. PORTABLE SAMPLER FOR PESTICIDES AND SEMIVOLATILE INDUSTRIAL ORGANIC CHEMICALS IN AIR

    EPA Science Inventory

    A battery powered, low volume air sampling system utilizing polyurethane form (PUF) as a trapping medium has been developed and evaluated. The sampler provides air flows of up to 4 L/min affording theoretical detection limits of less than 0.1 microgram/cu m for most chemicals tes...

  10. Underground-noise interference effects of the personal respirable coal-mine-dust sampler

    SciTech Connect

    Giardino, D.A.

    1981-01-01

    The primary purpose of this study is to determine the potential interference effects of the noise emitted by the MSA Model G and Bendix Model 3900 personal respirable coal mine dust samplers in relation to underground warning and communication signals. The first part of the investigation involves the acoustical characterization of noise radiated by the dust samplers in terms of noise level and spectral content. In the second part of the study, these data are compared to the noise levels and octave band spectra of warning signals (roof talk and emergency alarms) and voice communication signals. Finally, the health hazard potential for hearing loss due to dust sampler noise is examined. It can be concluded that the noise emissions from either the MSA Model G or the Bendix Model 3900 dust samplers: will not, for all practical purposes, significantly interfere with face to face verbal communications between individuals at the face of an underground coal mine; will not significantly interfere with telephone communications as conducted in an underground coal mine; will not significantly interfere with the miner's ability to hear roof talk acoustic signals; will not significantly interfere with the miner's ability to hear warning signals such as emergency alarams as used in an underground coal mine; and will not be a health hazard to miners-that is, prolonged or extended exposure will not cause hearing loss.

  11. Evaluation of two passive samplers for the analysis of organophosphate esters in the ambient air.

    PubMed

    Liu, Ruirui; Lin, Yongfeng; Liu, Runzeng; Hu, Fanbao; Ruan, Ting; Jiang, Guibin

    2016-01-15

    Both polyurethane foam (PUF) and sorbent-impregnated PUF (SIP) passive air sampling (PAS) methods were deployed and compared separately for the analysis of organophosphate esters (OPEs) in outdoor atmospheric environment. During an continuous period of 84 days, parallel samples were also collected by a high-volume active air sampler (HV-AAS) to assess the contamination levels and to calibrate uptake parameters of PAS. The total concentration of OPEs in both particulate and gaseous phases ranged from 1.50 to 5.64ng m(-3) in ambient air. Tris(2-chloroisopropyl) phosphate (TCPP) was the dominating analog, representing 78±9% of total OPE concentration. SIP-PAS showed longer linear-phase sampling period for TCPP, and accumulated more amount of the most volatile triethyl phosphate (TEP) and tributyl phosphate (TBP) homologues, while similar sorption performances of both PAS methods were found for most of the semi-volatile OPEs. Linear sampling rates in PUF-PAS and SIP-PAS disks were calculated for individual OPEs except for TEP and TBP, and the average uptake rates (3.3±1.1 and 3.5±1.7m(3)d(-1), respectively) were close to the acknowledged value (4m(-3)d(-1)) for persistent organic pollutants. Besides, isotopic labeled D15-Triphenyl phosphate (TPhP) could be used as a viable depuration compound to calculate site-specific sampling rates of OPEs, with a linear loss of up to ∼60% at the end of deployment time. PMID:26592578

  12. A Comparative View of the Roles of Women and Men: Grades 6-12. Comparative Studies Series.

    ERIC Educational Resources Information Center

    Miller, Barbara; And Others

    Designed to supplement intermediate or secondary level courses on sex roles or the family, the activities in this handbook enable students to examine changing sex roles and their effects on individuals and society. Materials are presented in three parts. Activities on perception and awareness (part 1) focus on identifying and reducing sex role…

  13. Solid versus Liquid Particle Sampling Efficiency of Three Personal Aerosol Samplers when Facing the Wind

    PubMed Central

    Koehler, Kirsten A.; Anthony, T. Renee; Van Dyke, Michael

    2016-01-01

    The objective of this study was to examine the facing-the-wind sampling efficiency of three personal aerosol samplers as a function of particle phase (solid versus liquid). Samplers examined were the IOM, Button, and a prototype personal high-flow inhalable sampler head (PHISH). The prototype PHISH was designed to interface with the 37-mm closed-face cassette and provide an inhalable sample at 10 l min−1 of flow. Increased flow rate increases the amount of mass collected during a typical work shift and helps to ensure that limits of detection are met, particularly for well-controlled but highly toxic species. Two PHISH prototypes were tested: one with a screened inlet and one with a single-pore open-face inlet. Personal aerosol samplers were tested on a bluff-body disc that was rotated along the facing-the-wind axis to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. When compared to published data for facing-wind aspiration efficiency for a mouth-breathing mannequin, the IOM oversampled relative to mannequin facing-the-wind aspiration efficiency for all sizes and particle types (solid and liquid). The sampling efficiency of the Button sampler was closer to the mannequin facing-the-wind aspiration efficiency than the IOM for solid particles, but the screened inlet removed most liquid particles, resulting in a large underestimation compared to the mannequin facing-the-wind aspiration efficiency. The open-face PHISH results showed overestimation for solid particles and underestimation for liquid particles when compared to the mannequin facing-the-wind aspiration efficiency. Substantial (and statistically significant) differences in sampling efficiency were observed between liquid and solid particles, particularly for the Button and screened-PHISH, with a majority of aerosol mass depositing on the screened inlets of these samplers. Our results suggest that large droplets have low penetration efficiencies

  14. Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study

    PubMed Central

    Coggins, Marie A.; Healy, Catherine B.; Lee, Taekhee; Harper, Martin

    2015-01-01

    Restoration stone work regularly involves work with high-silica-content materials (e.g., sandstone), but low-silica-content materials (<2 % quartz) such as limestone and lime mortar are also used. A combination of short sample duration and low silica content makes the quantification of worker exposure to respirable crystalline silica (RCS) difficult. This problem will be further compounded by the introduction of lower occupational exposure standards for RCS. The objective of this work was to determine whether higher-flow samplers might be an effective tool in characterizing lower RCS concentrations. A short study was performed to evaluate the performance of three high-flow samplers (FSP10, CIP10-R, and GK2.69) using side-by-side sampling with low-flow samplers (SIMPEDS and 10-mm nylon cyclones) for RCS exposure measurement at a restoration stonemasonry field site. A total of 19 side-by-side sample replicates for each high-flow and low-flow sampler pair were collected from work tasks involving limestone and sandstone. RESULTS. Most of the RCS (quartz) masses collected with the high-flow-rate samplers were above the limit of detection (62 % to 84 %) relative to the low-flow-rate samplers (58 % to 78 %). The average of the respirable mass concentration ratios for CIP10-R/SIMPEDS, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs and the range of the quartz concentration ratios for the CIP10-R/SIMPEDS, CIP10-R/10-mm nylon, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs included unity with an average close to unity, indicating no likely difference between the reported values for each sampler. Workers reported problems related to the weight of the sampling pumps for the high-flow-rate samplers. Respirable mass concentration data suggest that the high-flow-rate samplers evaluated would be appropriate for sampling respirable dust concentrations during restoration stone work. Results from the comparison of average quartz concentration ratios

  15. A new sampler for collecting separate dry and wet atmospheric depositions of trace organic chemicals

    NASA Astrophysics Data System (ADS)

    Waite, Don T.; Cessna, Allan J.; Gurprasad, Narine P.; Banner, James

    Studies conducted in Saskatchewan and elsewhere have demonstrated the atmospheric transport of agricultural pesticides and other organic contaminants and their deposition into aquatic ecosystems. To date these studies have focused on ambient concentrations in the atmosphere and in wet precipitation. To measure the dry deposition of organic chemicals, a new sampler was designed which uses a moving sheet of water to passively trap dry particles and gasses. The moving sheet of water drains into a reservoir and, during recirculation through the sampler, is passed through an XAD-2 resin column which adsorbs the trapped organic contaminants. All surfaces which contact the process water are stainless steel or Teflon. Chemicals collected can be related to airborne materials depositing into aquatic ecosystems. The sampler has received a United States patent (number 5,413,003 - 9 May 1996) with the Canadian patent pending. XAD-2 resin adsorption efficiencies for 10 or 50 μg fortifications of ten pesticides ranged from 76% for atrazine (2-chloro-4-ethylamino-6-isopropylamino- S-triazine) to 110% for triallate [ S-(2,3,3-trichloro-2-phenyl)bis(1-methylethyl)carbamothioate], dicamba (2-methoxy-3,6-dichlorobenzoic acid) and toxaphene (chlorinated camphene mixture). Field testing using duplicate samplers showed good reproducibility and amounts trapped were consistent with those from high volume and bulk pan samplers located on the same site. Average atmospheric dry deposition rates of three chemicals, collected for 5 weeks in May and June, were: dicamba, 69 ng m -2 da -1; 2,4-D (2,4-dichlorophenoxyacetic acid), 276 ng m -2 da -1: and, γ-HCH ( γ-1, 2, 3, 4, 5, 6-hexachlorocyclohexane), 327 ng m -2 da -1.

  16. Hands-On Whole Science: A Leaf Sampler.

    ERIC Educational Resources Information Center

    Kepler, Lynne

    1991-01-01

    Presents two elementary school activities to help students learn about autumn. The activities use autumn leaves to teach that each type of tree has its own distinctive type of leaf. One activity involves tracing, drawing, and writing about leaves; the other involves making a quilt using leaf designs. (SM)

  17. Polydimethylsiloxane-based permeation passive air sampler. Part I: Calibration constants and their relation to retention indices of the analytes.

    PubMed

    Seethapathy, Suresh; Górecki, Tadeusz

    2011-01-01

    A simple and cost effective permeation passive sampler equipped with a polydimethylsiloxane (PDMS) membrane was designed for the determination of time-weighted average (TWA) concentrations of volatile organic compounds (VOCs) in air. Permeation passive samplers have significant advantages over diffusive passive samplers, including insensitivity to moisture and high face velocities of air across the surface of the sampler. Calibration constants of the sampler towards 41 analytes belonging to alkane, aromatic hydrocarbon, chlorinated hydrocarbon, ester and alcohol groups were determined. The calibration constants allowed for the determination of the permeability of PDMS towards the selected analytes. They ranged from 0.026 cm² min⁻¹ for 1,1-dichloroethylene to 0.605 cm² min⁻¹ for n-octanol. Further, the mechanism of analyte transport across PDMS membranes allowed for the calibration constants of the sampler to be estimated from the linear temperature programmed retention indices (LTPRI) of the analytes, determined using GC columns coated with pure PDMS stationary phases. Statistical analysis using Student's t test indicated that there was no significant difference at the 95% probability level between the experimentally obtained calibration constants and those estimated using LTPRI for most analyte groups studied. This correlation allows the estimation of the calibration constants of compounds not known to be present at the time of sampler deployment, which makes it possible to determine parameters like total petroleum hydrocarbons in the vapor phase. PMID:21112594

  18. Determination of respirable mass concentration using a high volume air sampler and a sedimentation method for fractionation

    SciTech Connect

    Johnson, J.

    1995-12-31

    A preliminary study of a new method for determining respirable mass concentration is described. This method uses a high volume air sampler and subsequent fractionation of the collected mass using a particle sedimentation technique. Side-by-side comparisons of this method with cyclones were made in the field and in the laboratory. There was good agreement among the samplers in the laboratory, but poor agreement in the field. The effect of wind on the samplers` capture efficiencies is the primary hypothesized source of error among the field results. The field test took place at the construction site of a hazardous waste landfill located on the Hanford Reservation.

  19. Straight Talk about Risks: A Pre-K-12 Curriculum for Preventing Gun Violence. Grades 6-12.

    ERIC Educational Resources Information Center

    Center To Prevent Handgun Violence, Washington, DC.

    Straight Talk about Risks (STAR) is a pre-kindergarten through grade 12 curriculum designed to reduce the potential for children and teens to be injured or killed in gunfire. STAR is based on sound prevention practice developed from a pilot project in Dade County (Florida). The flexible format allows activities to fit into a 3-week classroom unit…

  20. Action for a Cleaner Tomorrow: A South Carolina Environmental Curriculum Grades 6-12, 2nd Edition.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Health and Environmental Control, Columbia.

    The goal of this curriculum is to teach students to think about their daily habits and to make environmentally responsible choices. The lessons and activities are divided by grade levels: 6-8 and 9-12. Lessons in each grade level are designed to cover a range of student skills, subject areas, and environmental issues. An extensive resource section…

  1. Set the P.A.C.E.! A Curriculum to Promote Mother-Child Communication about Sexuality and Reduce Sexual Risk Behaviors in Children Ages 6-12

    ERIC Educational Resources Information Center

    DiIorio, Colleen K.; Pluhar, Erika I.; Pines, Kathy; Jennings, Tanya

    2006-01-01

    In this article, we describe the Set the P.A.C.E.! (Parents And Children Empowered) curriculum designed for mothers of children 6-12 years of age. The development of the curriculum was part of a research study to test an intervention to enhance the mother's role in promoting resilience among 6- to 12-year-old children and to reduce the risk of…

  2. Carbon Nanotube Integrative Sampler (CNIS) for passive sampling of nanosilver in the aquatic environment.

    PubMed

    Shen, Li; Fischer, Jillian; Martin, Jonathan; Hoque, Md Ehsanul; Telgmann, Lena; Hintelmann, Holger; Metcalfe, Chris D; Yargeau, Viviane

    2016-11-01

    Nanomaterials such as nanosilver (AgNP) can be released into the aquatic environment through production, usage, and disposal. Sensitive and cost-effective methods are needed to monitor AgNPs in the environment. This work is hampered by a lack of sensitive methods to detect nanomaterials in environmental matrixes. The present study focused on the development, calibration and application of a passive sampling technique for detecting AgNPs in aquatic matrixes. A Carbon Nanotube Integrative Sampler (CNIS) was developed using multi-walled carbon nanotubes (CNTs) as the sorbent for accumulating AgNPs and other Ag species from water. Sampling rates were determined in the laboratory for different sampler configurations and in different aquatic matrixes. The sampler was field tested at the Experimental Lakes Area, Canada, in lake water dosed with AgNPs. For a configuration of the CNIS consisting of CNTs bound to carbon fiber (i.e. CNT veil) placed in Chemcatcher® housing, the time weighted average (TWA) concentrations of silver estimated from deployments of the sampler in lake mesocosms dosed with AgNPs were similar to the measured concentrations of "colloidal silver" (i.e. <0.22μm in size) in the water column. For a configuration of CNIS consisting of CNTs in loose powder form placed in a custom made housing that were deployed in a whole lake dosed with AgNPs, the estimated TWA concentrations of "CNIS-labile Ag" were similar to the concentrations of total silver measured in the epilimnion of the lake. However, sampling rates for the CNIS in various matrixes are relatively low (i.e. 1-20mL/day), so deployment periods of several weeks are required to detect AgNPs at environmentally relevant concentrations, which can allow biofilms to develop on the sampler and could affect the sampling rates. With further development, this novel sampler may provide a simple and sensitive method for screening for the presence of AgNPs in surface waters. PMID:27343941

  3. Ambient Ammonia Monitoring in the Central United States Using Passive Diffusion Samplers

    NASA Astrophysics Data System (ADS)

    Caughey, M.; Gay, D.; Sweet, C.

    2008-12-01

    Environmental scientists and governmental authorities are increasingly aware of the need for more comprehensive measurements of ambient ammonia in urban, rural and remote locations. As the predominant alkaline gas, ammonia plays a critical role in atmospheric chemistry by reacting readily with acidic gases and particles. Ammonium salts often comprise a major portion of the aerosols that impair visibility, not only in urban areas, but also in national parks and other Class I areas. Ammonia is also important as a plant nutrient that directly or indirectly affects terrestrial and aquatic biomes. Successful computer simulations of important environmental processes require an extensive representative data set of ambient ammonia measurements in the range of 0.1 ppbv or greater. Generally instruments with that level of sensitivity are not only expensive, but also require electrical connections, an enclosed shelter and, in many instances, frequent attention from trained technicians. Such requirements significantly restrict the number and locations of ambient ammonia monitors that can be supported. As an alternative we have employed simple passive diffusion samplers to measure ambient ammonia at 9 monitoring sites in the central U.S. over the past 3 years. Passive samplers consist of a layer of an acidic trapping medium supported at a fixed distance behind a microporous barrier for which the diffusive properties are known. Ammonia uptake rates are determined by the manufacturer under controlled laboratory conditions. (When practical, field results are compared against those from collocated conventional samplers, e.g., pumped annular denuders.) After a known exposure time at the sampling site, the sampler is resealed in protective packaging and shipped to the analytical laboratory where the ammonia captured in the acidic medium is carefully extracted and quantified. Because passive samplers are comparatively inexpensive and do not require electricity or other facilities they

  4. Colloquium on the Law of Outer Space, 33rd, Dresden, Federal Republic of Germany, Oct. 6-12, 1990, Proceedings

    SciTech Connect

    Not Available

    1991-01-01

    The present conference on the law of outer space encompasses the legal implications of space commercialization, recent developments in space law, space debris, international cooperation in space, the legality of military space observations, and the legal dimensions of East-West satellite communications. Specific issues addressed include the concepts related to insurance for space activities conducted jointly by governments and the private sector, the international liability ramifications of the U.S. Navstar GPS system, legal and political measures to deal with CFCs and stratospheric ozone, and the convergence of telecommunication technologies. Also addressed are the recent activities on the Space Station, equity and international space law, the legal aspects of verification in and from outer space, satellite verification and European arms control, the regulation of space debris, and the 'right' of passage into outer space.

  5. Comparing the Accumulation of PCBs by Passive Samplers and Mussels from the Water Column at a Contaminated Sediment Site

    EPA Science Inventory

    Passive samplers, including semi-permeable membrane devices (SPMDs), solid phase microextraction (SPME) and polyethylene devices (PEDs), provide innovative tools for measuring hydrophobic organic contaminants (HOCs) originating from contaminated waters and sediments. Because the...

  6. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM 2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤Rc ≤105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2...

  7. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM 2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2...

  8. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel Evaluation...% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr and...

  9. 40 CFR Table F-1 to Subpart F of... - Performance Specifications for PM2.5 Class II Equivalent Samplers

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel Evaluation...: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2...

  10. AUTOMATIC PARTICULATE SULFUR MEASUREMENTS WITH A DICHOTOMOUS SAMPLER AND ON-LINE X-RAY FLUORESCENCE ANALYSIS

    EPA Science Inventory

    An instrument is described which employs a dichotomous sampler to acquire fine particulate samples on a continuous tape filter. Analyses for elemental sulfur are performed immediately following acquisition using a sensitive X-ray fluorescence spectrometer. Sample sequencing, data...

  11. A field calibration of the sediment-trapping characteristics of the Helley-Smith bed-load sampler

    USGS Publications Warehouse

    Emmett, William W.

    1980-01-01

    For sediment particle sizes between 0.50 mm and 16 mm, the Helley-Smith bedload sampler has a near perfect sediment-trapping efficiency. For particles sizes smaller than 0.50 mm, the Helley-Smith sampler has a high bedload sediment-trapping efficiency because part of the sediement retained by the sampler has been transported in suspension and it cannot be quantified separately from the bedload. For particle sizes larger than about 16 mm, the Helley-Smith sampler has low sediment-trapping efficiency but this may be related to the paucity of coarse particles in transport in the calibration tests rather than reflecting an actual low trap efficiency for large-size particles. (USGS)

  12. Use of passive ambient ozone (O3) samplers in vegetation effects assessment

    USGS Publications Warehouse

    Krupa, S.; Nosal, M.; Peterson, D.L.

    2001-01-01

    A stochastistic, Weibull probability model was developed and verified to simulate the underlying frequency distributions of hourly ozone (O3) concentrations (exposure dynamics) using the single, weekly mean values obtained from a passive (sodium nitrite absorbent) sampler. The simulation was based on the data derived from a co-located continuous monitor. Although at the moment the model output may be considered as being specific to the elevation and location of the study site, the results were extremely good. This effort for the approximation of the O3 exposure dynamics can be extended to other sites with similar data sets and in developing a generalized understanding of the stochastic O3 exposure-plant response relationships, conferring measurable benefits to the future use of passive O3 samplers, in the absence of continuous monitoring. Copyright ?? 2000 Elsevier Science Ltd.

  13. Test plan for phase II of the Retained Gas Sampler system

    SciTech Connect

    Hey, B.E.

    1995-06-19

    The Retained Gas Sampler (RGS) system is being developed to permit characterization of the gas phase component of waste tank core samples. Several laboratory experiments have been conducted which have affirmed the proof-of-principle for separating the gas phase materials from waste tank material in a quantitative manner. However, experiments conducted thus far have dealt only with representative materials and simulated hardware mock-ups. This test plan deals with the operation and testing of actual devices in the hot cell environment. This test plan coves all aspects of the RGS system including: sampler load-in, extrusion, gas extraction, quantitative separation, sample collection, and quantitative analysis. Sample material used in this test plan will be waste tank simulants and will not be radioactive. The work environment, however, will be an operating hot cell facility and will have radioactive contaminated surfaces. Operation of the system will therefore require an official radiation work permit (RWP).

  14. DSP based lunar sampling control system for the coiling-type sampler

    NASA Astrophysics Data System (ADS)

    Ling, Yun; Song, Aiguo; Lu, Wei

    2011-12-01

    The paper develops a control system based on DSP28334 for lunar sampling, and provides the main structure of it. The critical hardware and software design of the system are introduced in detail. The emphasis is placed on the design and realization of the vibration control of the coiling-type sampler in the process of lunar sampling. A control strategy which combines manual-control and local autonomous control is applied for the lunar sampling control. And the sampling mechanism being controlled can realizes multi-motor units working at time-sharing, which reduces the power comsumption and increases the stability of the sampling system greatly. The practical application of the control strategy used for the coiling-type sampler is verified by the finite element analysis. The experiments results show that the system works with low power consumption and high efficiency, and the proposed strategy enables greater depth and better efficiency during sampling.

  15. Passive samplers and community science in regional air quality measurement, education and communication.

    PubMed

    DeForest Hauser, Cindy; Buckley, Alexandra; Porter, Juliana

    2015-08-01

    Charlotte, in Mecklenburg County, North Carolina, was ranked in the top ten cities with the worst air quality for ozone in the United States by the American Lung Association from 2009 to 2011. Nearby counties that may experience similar air quality do not have state or county monitors. This study utilized NOx and ozone Ogawa passive samplers and community scientists to monitor air quality in five counties surrounding Charlotte and increase public engagement in air quality issues. Community scientists deployed samplers weekly at a residential site within each county. Samples were analyzed using spectrophotometry and ion chromatography. Elevated NOx concentrations were observed in four of the five counties relative to those with existing monitors. Ozone concentrations showed little county to county variation, except Iredell and Cabarrus which had higher concentrations than Rowan. Community involvement in this work led to an increase in local dissemination of the results, thus increasing air quality awareness. PMID:25556581

  16. Development of a low-density polyethylene-containing passive sampler for measuring dissolved hydrophobic organic compounds in open waters.

    PubMed

    Bao, Lian-Jun; Xu, Shi-Ping; Liang, Yan; Zeng, Eddy Y

    2012-05-01

    A passive water sampler with low-density polyethylene (LDPE) as the sorbent phase was built and field-tested for sensing freely dissolved concentrations of hydrophobic organic compounds (HOCs) in fresh and coastal water. Based on the measured LDPE-water partition coefficients (K(pew)) of 12 polycyclic aromatic hydrocarbons (PAHs) and dichlorodiphenyltrichloroethane (DDT) and its seven metabolites, the detection limits with the passive sampler containing 10-g LDPE ranged from 0.04 to 56.9 pg/L in the equilibrium sampling mode. Furthermore, the utility of the passive sampler in measuring dissolved HOC concentrations in open waters was examined through a comparison with solid-phase extraction combined with liquid-liquid extraction (SPE-LLE) and poly(dimethyl)siloxane (PDMS) coated fiber samplers. The total concentrations of PAHs (3.8-16 ng/L) obtained by the passive sampler were lower than those (87.7-115.5 ng/L) obtained through SPE-LLE. This large difference was probably attributable to slower water exchange in and out of the passive sampler as time progressed because of blockage by algae in eutrophia reservoirs and high dissolved organic carbon contents resulting in higher-than-expected PAH concentrations by SPE-LLE. Furthermore, the concentrations and compositional profiles of DDXs (sum of p,p'-DDT, p,p'-DDD, p,p'-DDE, o,p'-DDT, o,p'-DDD, o,p'-DDE, and p,p'-DDMU) at site A obtained by the passive sampler agreed with the results obtained with the PDMS-coated fibers, suggesting that the passive sampler was able to reasonably quantify dissolved HOCs in seawater. PMID:22388779

  17. A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz.

    PubMed

    Verpaele, Steven; Jouret, Jonathan

    2013-01-01

    The divergent sampling techniques for respirable dust and the analyses for crystalline silica are an important area of interest and discussion among industrial occupational hygienists in Europe. The variety of equipment for air sampling, methods and instrumentation can cause differences between results for the analysis of respirable crystalline silica (RCS). In this study, a Workplace Atmosphere Multi-sampler (WAM), developed by Adhesia, was used to compare respirable dust samplers in the workplace. This rotating device enables the comparison of 12 samplers in a workplace in each run. Seven laboratories participated in the comparison, using six different respirable dust samplers [British Cast Iron Research Association (BCIRA) to the Higgins Dewell (HD) design, Dorr Oliver, Casella SIMPEDS, SKC HD with a polycarbonate filter and polyvinylchloride filter, and the CIP10-R). Each laboratory analysed samples supplied by the samplers and reported the total respirable dust concentration and the RCS concentration. The techniques used were X-ray diffraction direct-on-filter, X-ray diffraction with deposition, infrared direct-on-filter, and infrared with potassium bromide (KBr) discs. The experiments were carried out in four different industries (enamel, sand extraction, foundry and brickworks). Generally, the SKC conductive black plastic sampler is oversampled (y = 1.52x + 0.008) and the CIP10 is undersampled (y = 0.74x + 0.068) when compared with the median air concentration. A pair-wise comparison of the different industries using t-tests indicated significant differences (P < 0.05) between the SKC conductive plastic samplers and the other samplers. The same series of statistical calculations were performed for the results obtained for RCS (quartz) and showed significant differences for the CIP10 techniques and the SKC conductive plastic cyclone analyses when using a polyvinylchloride filter. PMID:22826536

  18. Diffusion sampler testing at Naval Air Station North Island, San Diego County, California, November 1999 to January 2000

    USGS Publications Warehouse

    Vroblesky, Don A.; Peters, Brian C.

    2000-01-01

    Volatile organic compound concentrations in water from diffusion samplers were compared to concentrations in water obtained by low-flow purging at 15 observation wells at the Naval Air Station North Island, San Diego, California. Multiple diffusion samplers were installed in the wells. In general, comparisons using bladder pumps and diffusion samplers showed similar volatile organic carbon concentrations. In some wells, sharp concentration gradients were observed, such as an increase in cis-1,2-dichloroethene concentration from 100 to 2,600 micrograms per liter over a vertical distance of only 3.4 feet. In areas where such sharp gradients were observed, concentrations in water obtained by low-flow sampling at times reflected an average concentration over the area of influence; however, concentrations obtained by using the diffusion sampler seemed to represent the immediate vicinity of the sampler. When peristaltic pumps were used to collect ground-water samples by low-flow purging, the volatile organic compound concentrations commonly were lower than concentrations obtained by using diffusion samplers. This difference may be due to loss of volatiles by degassing under negative pressures in the sampling lines induced while using the peristaltic pump, mixing in the well screen, or possible short-circuiting of water from an adjacent depth. Diffusion samplers placed in buckets of freephase jet fuel (JP-5) and Stoddard solvent from observation wells did not show evidence of structural integrity loss during the 2 months of equilibration, and volatile organic compounds detected in the free-phase fuel also were detected in the water from the diffusion samplers.

  19. High volume electrostatic field-sampler for collection of fine particle bulk samples

    NASA Astrophysics Data System (ADS)

    Kumar Sharma, Anoop; Wallin, Håkan; Alstrup Jensen, Keld

    A high volume electrostatic field-sampler was developed for collection of fine particles, which easily can be recovered for subsequent sample characterisation and bioassays. The sampler was based on a commercial office air cleaner and consisted of a prefilter followed by electrostatic collection plates operating at 2.7 kV. The sampler performance was characterised for 26 nm to 5.4 μm-size particles in urban street air. The collection efficiency reached a maximum (60-70%) between 0.2 and 0.8 μm and dropped to ˜25% at 30 nm and 2.5 μm, respectively. After extraction in water, the particle loss was<2%. The extraction efficiency for dry lyophilised particulate matter was above 80%, allowing retrievement of ˜12 mg day -1 in urban street air at PM 10 levels of ˜24 μg m -3. The ozone generating capacity of the corona discharge during operation was on the order of 10 ppb. A polycyclic aromatic hydrocarbons (PAH) degradation test using benzo[a]pyrene as a model showed that ˜85% was degraded after 24 h. However, similar results were observed when the corona discharge was switched off. Hence, the ozone and other corona discharge reactants do not appear to contribute considerably to PAH-degradation. The overall results show that the sampler type is a promising alternative to traditional sampling of fine particles for bulk analysis and bioassays. The main advantages are simple operation, high stability, high quantifiable particle recovery rates and low cost.

  20. Development of a new passive sampler based on diffusive milligel beads for copper analysis in water.

    PubMed

    Perez, M; Reynaud, S; Lespes, G; Potin-Gautier, M; Mignard, E; Chéry, P; Schaumlöffel, D; Grassl, B

    2015-08-26

    A new passive sampler was designed and characterized for the determination of free copper ion (Cu(2+)) concentration in aqueous solution. Each sampling device was composed of a set of about 30 diffusive milligel (DMG) beads. Milligel beads with incorporated cation exchange resin (Chelex) particles were synthetized using an adapted droplet-based millifluidic process. Beads were assumed to be prolate spheroids, with a diameter of 1.6 mm and an anisotropic factor of 1.4. The milligel was controlled in chemical composition of hydrogel (monomer, cross-linker, initiator and Chelex concentration) and characterized in pore size. Two types of sampling devices were developed containing 7.5% and 15% of Chelex, respectively, and 6 nm pore size. The kinetic curves obtained demonstrated the accumulation of copper in the DMG according to the process described in the literature as absorption (and/or adsorption) and release following the Fick's first law of diffusion. For their use in water monitoring, the typical physico-chemical characteristics of the samplers, i.e. the mass-transfer coefficient (k0) and the sampler-water partition coefficient (Ksw), were determined based on a static exposure design. In order to determine the copper concentration in the samplers after their exposure, a method using DMG bead digestion combined to Inductively Coupled Plasma - Atomic Emission Spectrometry (ICP-AES) analysis was developed and optimized. The DMG devices proved to be capable to absorb free copper ions from an aqueous solution, which could be accurately quantified with a mean recovery of 99% and a repeatability of 7% (mean relative uncertainty). PMID:26347173

  1. Field calibration of low density polyethylene passive samplers for gaseous POPs.

    PubMed

    Khairy, Mohammed A; Lohmann, Rainer

    2014-03-01

    A field calibration study of low density polyethylene (LDPE) for measuring atmospheric concentrations of persistent organic pollutants (POPs) was performed in East Providence (RI), USA. LDPE samplers were collected after 3, 7, 10, 14, 17 and 21 days of exposure along with samples from a co-deployed high volume sampler. Uptake kinetics of POPs by LDPEs were confirmed both by using an uptake study over time and the inclusion of performance reference compounds (PRCs). Results indicated that only POPs with log sampler-air partitioning coefficient (KPE-A) ≤ 7.6 were approaching equilibrium by the end of the deployment period, whereas all the other POPs were still in the linear uptake rate. Sampling rates (1.0-80 m(3) per day) were higher for some POPs when compared to literature values possibly due to the open sampler housing design used. Derived KPE-As for the detected POPs in field calibration study were correlated against the compounds' octanol-air partitioning coefficients (log KOA): [log KPE-A = 0.88 ± 0.02 × log KOA + 0.40 ± 0.21 (R(2) = 0.96; n = 59; SE = 0.23)], and their subcooled liquid vapour pressures (log PL/Pa): [log KPE-A = -0.82 ± 0.02 × log PL + 6.22 ± 0.05 (R(2) = 0.96; n = 59; SE = 0.22)] to predict values for all POPs. PL was generally found to be a better predictor of KPE-A for all POPs. PMID:24270460

  2. Calibration and maintenance procedures for coal mine respirable dust samplers. Informational report

    SciTech Connect

    Tomb, T.F.; Parobeck, P.S.

    1996-05-01

    The Federal Mine Safety and Health Act of 1977 requires that the average concentration of respirable coal mine dust be measured with a device approved by the Secretary of Labor and the Secretary of Health and Human Services. The information report describes the standard procedures used by the Mine Safety and Health Administration (MSHA) for calibration of current approved personal samplers and associated equipment and for maintenance of this equipment.

  3. Sampling and conditioning artifacts of PM2.5 in filter-based samplers

    NASA Astrophysics Data System (ADS)

    Liu, Chun-Nan; Lin, Sih-Fan; Awasthi, Amit; Tsai, Chuen-Jinn; Wu, Yueh-Chuen; Chen, Chung-Fang

    2014-03-01

    Field studies were conducted at Taiwan National Chiao-Tung University (NCTU) campus to evaluate the evaporation loss of fine particles (PM2.5) collected by the multi-filter PM10-PM2.5 sampler (MFPPS), which was collocated with a dichotomous sampler (Dichot, Andersen, Model SA-241), a WINS PM2.5 sampler (Thermo, Model 2000-FRM), and a tapered element oscillating microbalance with the filter dynamic measurement system (TEOM-FDMS, Thermo, Model 1405-DF). Porous-metal denuder samplers (PDSs) were installed in sampling channels of the MFPPS to measure the concentration of evaporated ion species. Results showed that the evaporation loss in PM2.5 was severe during sampling, accounting for 5.8-36.0% of the corrected PM2.5 concentration and the percentage increased with decreasing loaded particle mass and increasing filtration velocity. During 24-h sampling, the evaporated NH4+, NO3- and Cl- concentrations accounted for 9.5 ± 6.2, 5.4 ± 3.7, and 2.0 ± 1.3% in corrected PM2.5 concentration, respectively, or 46.4 ± 19.2, 66.9 ± 18.5, and 74.4 ± 14.0% in the concentration of each species, respectively. Due to the evaporation loss, PM2.5 concentrations measured by the WINS, Dichot, and MFPPS were lower than those the TEOM-FDMS by 16.6 ± 9.0, 15.2 ± 10.6 and 12.5 ± 8.8%, respectively. When the MFPPS PM2.5 concentrations were corrected for the evaporated loss determined by the PDS, good agreement with those by the TEOM-FDMS was achieved.

  4. Field and Wind Tunnel Comparison of Four Aerosol Samplers Using Agricultural Dusts

    PubMed Central

    Reynolds, Stephen J.; Nakatsu, Jason; Tillery, Marvin; Keefe, Thomas; Mehaffy, John; Thorne, Peter S.; Donham, Kelley; Nonnenmann, Matthew; Golla, Vijay; O'shaughnessy, Patrick

    2009-01-01

    Occupational lung disease is a significant problem among agricultural workers exposed to organic dusts. Measurements of exposure in agricultural environments in the USA have traditionally been conducted using 37-mm closed-face cassettes (CFCs) and respirable Cyclones. Inhalable aerosol samplers offer significant improvement for dose estimation studies to reduce respiratory disease. The goals of this study were to determine correction factors between the inhalable samplers (IOM and Button) and the CFC and Cyclone for dusts sampled in livestock buildings and to determine whether these factors vary among livestock types. Determination of these correction factors will allow comparison between inhalable measurements and historical measurements. Ten sets of samples were collected in swine, chicken, turkey, and dairy facilities in both Colorado and Iowa. Pairs of each sampling device were attached to the front and back of a rotating mannequin. Laboratory studies using a still-air chamber and a wind tunnel provided information regarding the effect of wind speed on sampler performance. Overall, the IOM had the lowest coefficient of variation (best precision) and was least affected by changes in wind speed. The performance of the Button was negatively impacted in poultry environments where larger (feather) particulates clogged the holes in the initial screen. The CFC/IOM ratios are important for comparisons between newer and older studies. Wind speed and dust type were both important factors affecting ratios. Based on the field studies (Table 6), a ratio of 0.56 is suggested as a conversion factor for the CFC/IOM (average for all environments because of no statistical difference). Suggested conversion factors for the Button/IOM are swine (0.57), chicken (0.80), turkey (0.53), and dairy (0.67). Any attempt to apply a conversion factor between the Cyclone and inhalable samplers is not recommended. PMID:19443852

  5. Performance evaluation of modified Semi-continuous Elements in Aerosol Sampler-III

    NASA Astrophysics Data System (ADS)

    Pancras, Joseph Patrick; Landis, Matthew S.

    2011-12-01

    A field study was conducted to evaluate the performance of a Semi-continuous Elements in Aerosol Sampler-III (SEAS-III), designed to collect ambient PM 2.5 aerosol samples at a time resolution of 30 min for elemental concentration measurements. Two identical but modified SEAS-III samplers were operated for four continuous weeks in Dearborn, MI, during July-August 2007. A total of 2308 samples were collected from the two samplers. Sampling completeness from the primary and duplicate samplers was 90% and 84%, respectively. All of the collected samples were analyzed for dilute acid-extractable trace metal concentrations using HR-ICPMS. A total of 878 collection time-matched sample pairs were available to evaluate whole-system uncertainty from collocated concentration measurements. The collocated precision for the 27 studied elements (Al, As, Ba, Ca, Cd, Ce, Cs, Cu, Fe, Ge, K, La, Mg, Mn, Mo, Na, P, Pb, Rb, S, Sb, Se, Sn, Sr, Ti, V, and Zn) varied between 9% and 40%. Twenty elements showed precision better than 25%. Uncertainty estimates from propagation of errors compared well with the whole-system uncertainty values for all minor aerosol elements studied. SEAS-III measurements of As, Cd, Ge, K, La, Mn, Mo, Na, Rb, Se, Sb, Sr, Ti, V, and Zn correlated well ( r > 0.8) with a FRM equivalent PM 2.5 integrated filter sampling method. Based on these measurements, collection efficiency of SEAS-III was estimated to be 87 ± 16%. Solubility of particles in the collection medium (water) was identified as a possible reason for low recovery of Al, Fe, Pb, Sb, and Sn.

  6. A personal sampler for aircraft engine cold start particles: laboratory development and testing.

    PubMed

    Armendariz, Alfredo; Leith, David

    2003-01-01

    Industrial hygienists in the U.S. Air Force are concerned about exposure of their personnel to jet fuel. One potential source of exposure for flightline ground crews is the plume emitted during the start of aircraft engines in extremely cold weather. The purpose of this study was to investigate a personal sampler, a small tube-and-wire electrostatic precipitator (ESP), for assessing exposure to aircraft engine cold start particles. Tests were performed in the laboratory to characterize the sampler's collection efficiency and to determine the magnitude of adsorption and evaporation artifacts. A low-temperature chamber was developed for the artifact experiments so tests could be performed at temperatures similar to actual field conditions. The ESP collected particles from 0.5 to 20 micro m diameter with greater than 98% efficiency at particle concentrations up to 100 mg/m(3). Adsorption artifacts were less than 5 micro g/m(3) when sampling a high concentration vapor stream. Evaporation artifacts were significantly lower for the ESP than for PVC membrane filters across a range of sampling times and incoming vapor concentrations. These tests indicate that the ESP provides more accurate exposure assessment results than traditional filter-based particle samplers when sampling cold start particles produced by an aircraft engine. PMID:14674798

  7. Bioaerosol sampling by a personal rotating cup sampler CIP 10-M.

    PubMed

    Görner, Peter; Fabriès, Jean-François; Duquenne, Philippe; Witschger, Olivier; Wrobel, Richard

    2006-01-01

    High concentrations of bioaerosols containing bacterial, fungal and biotoxinic matter are encountered in many workplaces, e.g. solid waste treatment plants, waste water treatment plants and sewage networks. A personal bioaerosol sampler, the CIP 10-M (M-microbiologic), has been developed to measure worker exposure to airborne biological agents. This sampler is battery operated; it is light and easy to wear and offers full work shift autonomy. It can sample much higher concentrations than biological impactors and limits the mechanical stress on the microorganisms. Biological particles are collected in 2 ml of liquid medium inside a rotating cup fitted with radial vanes to maintain an air flow rate of 10 l min(-1) at a rotational speed of approximately 7,000 rpm. The rotating cup is made of sterilisable material. The sampled particles follow a helicoidal trajectory as they are pushed to the surface of the liquid by centrifugal force, which creates a thin vertical liquid layer. Sterile water or another collecting liquid can be used. Three particle size selectors allow health-related aerosol fractions to be sampled according to international conventions. The sampled microbiological particles can be easily recovered for counting, incubation or further biochemical analysis, e.g., for airborne endotoxins. Its physical sampling efficiency was laboratory tested and field trials were carried out in industrial waste management conditions. The results indicate satisfactory collection efficiency, whilst experimental application has demonstrated the usefulness of the CIP 10-M personal sampler for individual bioaerosol exposure monitoring. PMID:16395458

  8. Performance of Passive Samplers for Monitoring Estuarine Water Column Concentrations: 2. Emerging Contaminants

    PubMed Central

    Perron, Monique M.; Burgess, Robert M.; Suuberg, Eric M.; Cantwell, Mark G.; Pennell, Kelly G.

    2014-01-01

    Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of three common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS) coated solid phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 to 18 ng/L for POM and 8.8 to 13 ng/L for PE using performance reference compound (PRC) equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. PMID:23595851

  9. Personal sampler for monitoring of viable viruses; modelling of outdoor sampling conditions

    NASA Astrophysics Data System (ADS)

    Borodulin, A. I.; Desyatkov, B. M.; Lapteva, N. A.; Sergeev, A. N.; Agranovski, I. E.

    A new personal bioaerosol sampler has recently been developed and verified to be very efficient for monitoring of viable airborne bacteria, fungi and viruses. The device is capable of providing high recovery rates even for microorganisms which are rather sensitive to physical and biological stresses. However, some mathematical procedure is required for realistic calculation of an actual concentration of viable bioaerosols in the air taking into account a rate of inactivation of targeted microorganisms, sampling parameters, and results of microbial analysis of collecting liquid from the sampler. In this paper, we develop such procedure along with the model of aerosol propagation for outdoor conditions. Combining these procedures allows one to determine the optimal sampling locations for the best possible coverage of the area to be monitored. A hypothetical episode concerned with terrorists' attack during music concert in the central square of Novosibirsk, Russia was considered to evaluate possible coverage of the area by sampling equipment to detect bioaerosols at various locations within the square. It was found that, for chosen bioaerosol generation parameters and weather conditions, the new personal sampler would be capable to reliably detect pathogens at all locations occupied by crowd, even at distances of up to 600 m from the source.

  10. Evaluating the efficiency of a one-square-meter quadrat sampler for riffle-dwelling fish

    USGS Publications Warehouse

    Peterson, J.T.; Rabeni, C.F.

    2001-01-01

    We evaluated the efficacy of a 1-m2 quadrat sampler for collecting riffle-dwelling fishes in an Ozark stream. We used a dual-gear approach to evaluate sampler efficiency in relation to species, fish size, and habitat variables. Quasi-likelihood regression showed sampling efficiency to differ significantly (P 0.05). Sampling efficiency was significantly influenced by physical habitat characteristics. Mean current velocity negatively influenced sampling efficiencies for Cyprinidae (P = 0.009), Cottidae (P = 0.006), and Percidae (P < 0.001), and the amount of cobble substrate negatively influenced sampling efficiencies for Cyprinidae (P = 0.025), Ictaluridae (P < 0.001), and Percidae (P < 0.001). Water temperature negatively influenced sampling efficiency for Cyprinidae (P = 0.009) and Ictaluridae (P = 0.006). Species-richness efficiency was positively influenced (P = 0.002) by percentage of riffle sampled. Under average habitat conditions encountered in stream riffles, the 1-m2 quadrat sampler was most efficient at estimating the densities of Cyprinidae (84%) and Cottidae (80%) and least efficient for Percidae (57%) and Ictaluridae (31%).

  11. A modified ceramic sampler and lysimeter design for improved monitoring of soil leachates.

    PubMed

    Bowman, Mark S; Clune, Timothy S; Sutton, Bruce G

    2002-02-01

    This paper describes the design and use of modified solution samplers and non-weighing lysimeters in a field experiment examining the response of a turf-soil system to landfill leachate irrigation over a 2-year period. The two designs were shown to offer significant performance advantages, were cost effective and overcame many of the reported problems commonly associated with each technique. The quantities of leached chloride detected in the 20%, 50% and undiluted leachate irrigated plots by the modified solution samplers (1,677, 4,319 and 8,021 kg ha(-1), respectively) and microlysimeters (1,759, 4,512 and 8,160 kg ha(-1), respectively) were significantly higher than the conventional sampler design (1,407, 3,767 and 7,052 kg ha(-1), respectively). Additionally, the microlysimeter design functioned reliably throughout the experiment, achieving solution flow rates analogous to the unconfined plots. Therefore, it was concluded that both the designs appear to be suitable for monitoring changes in soil solution composition associated with sub-surface wastewater irrigation. PMID:11827342

  12. Sampling of BTX in Hat Yai city using cost effective laboratory-built PCB passive sampler.

    PubMed

    Subba, Jas Raj; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2016-08-23

    A laboratory-built printed circuit board (PCB) passive sampler used for the monitoring of xylene and styrene in copy print shops was re-validated for detecting benzene, toluene and xylene (BTX) and applied for the sampling of ambient air from Hat Yai city, Songkhla, Thailand, in the month of November 2014. For monitoring, the PCB passive samplers were exposed to target analytes in 16 locations covering high to low exposure areas. After sampling, the samplers were thermally desorbed and the analytes were trapped by multi-walled carbon nanotubes packed into a micro-preconcentrator coupled to a gas chromatograph (GC) equipped with a flame ionization detector. At the optimum GC operating conditions, the linear dynamic ranges for BTX were 0.06-5.6 µg for benzene, 0.07-2.2 µg for toluene and 0.23-2.5 µg for xylene with R(2) > 0.99 with the limits of detection being 6.6, 6.8 and 19 ng for benzene, toluene and xylene, respectively. The concentrations of BTX in the 16 sampling sites were in the range of N.D.-1.3 ± 1.6, 4.50 ± 0.76-49.6 ± 3.7 and 1.00 ± 0.21-39.6 ± 3.1 µg m(-3), respectively. When compared to past studies, there had been an increase in the benzene concentration. PMID:27231039

  13. Assessment of benthic macroinvertebrates at Nile tilapia production using artificial substrate samplers.

    PubMed

    Moura E Silva, M S G; Graciano, T S; Losekann, M E; Luiz, A J B

    2016-05-17

    Biomonitoring is a cheap and effective tool for evaluation of water quality, and infer on the balance of aquatic ecosystems. The benthic macroinvertebrates are bioindicators sensitive to environmental changes, and can assist in detecting and preventing impacts such as organic enrichment and imbalance in the food chain. We compared the structure of benthic communities on artificial substrate samplers located in places near and far from net cages for production of Nile tilapia (Oreochromis niloticus). Samplers were manufactured with nylon net, using substrates such as crushed stone, gravel, loofah and cattail leaves. Samples were collected after 30 days of colonization, rinsed and then the specimens were identified and quantified. The following metrics were calculated: richness of Operational Taxonomic Units, Margalef richness, abundance of individuals, Shannon index and evenness index. The macrobenthic community structure was strongly modified according to the proximity of the net cages. Metrics showed significant differences (p < 0.05) between near and distant sites, for both periods (dry and rainy seasons). The position of the samplers significantly affected the structure of macroinvertebrate community, as near sites showed higher values for the community metrics, such as richness and diversity. Near sites presented a larger number of individuals, observed both in the dry and rainy seasons, with a predominance of Chironomidae (Diptera) in the dry season and Tubificidae (Oligochaeta) in the rainy season. PMID:27191461

  14. A Gibbs sampler for Bayesian analysis of site-occupancy data

    USGS Publications Warehouse

    Dorazio, Robert M.; Rodriguez, Daniel Taylor

    2012-01-01

    1. A Bayesian analysis of site-occupancy data containing covariates of species occurrence and species detection probabilities is usually completed using Markov chain Monte Carlo methods in conjunction with software programs that can implement those methods for any statistical model, not just site-occupancy models. Although these software programs are quite flexible, considerable experience is often required to specify a model and to initialize the Markov chain so that summaries of the posterior distribution can be estimated efficiently and accurately. 2. As an alternative to these programs, we develop a Gibbs sampler for Bayesian analysis of site-occupancy data that include covariates of species occurrence and species detection probabilities. This Gibbs sampler is based on a class of site-occupancy models in which probabilities of species occurrence and detection are specified as probit-regression functions of site- and survey-specific covariate measurements. 3. To illustrate the Gibbs sampler, we analyse site-occupancy data of the blue hawker, Aeshna cyanea (Odonata, Aeshnidae), a common dragonfly species in Switzerland. Our analysis includes a comparison of results based on Bayesian and classical (non-Bayesian) methods of inference. We also provide code (based on the R software program) for conducting Bayesian and classical analyses of site-occupancy data.

  15. Passive Samplers for Monitoring Insidious N Air Pollutants and Estimating N Deposition to Terrestrial Ecosystems

    NASA Astrophysics Data System (ADS)

    Bytnerowicz, A.

    2004-12-01

    Ammonia (NH3), nitric acid vapor (HNO3), nitric oxide (NO) and nitrogen dioxide (NO2) are the main biologically important nitrogenous (N) air pollutants. At highly elevated concentrations, these pollutants have a potential of causing injury to sensitive plants. More importantly, gaseous N pollutants may provide significant amounts of atmospheric N to the terrestrial ecosystems. This is especially true for wildlands affected by photochemical smog and agricultural emissions (e.g. mountains near California Central Valley or Los Angeles Basin). Passive samplers developed in the 1990s and 2000s have allowed for reliable monitoring of ambient concentrations of the pollutants at large geographic scales. Information on spatial and temporal distribution of NH3, HNO3, NO and NO2 from passive samplers may allow for determining potential "hot spots" of N pollutants effects. Information on ambient concentrations of gaseous N can also be used for estimates of N deposition to various ecosystems. Monitoring of N air pollutants and estimates of N deposition have been conducted in deserts, coastal sage, serpentine grassland, chaparral, and mixed conifer forests in California. These efforts and potential future use of passive samplers will be discussed.

  16. Accelerated solvent extraction (ASE) for purification and extraction of silicone passive samplers used for the monitoring of organic pollutants.

    PubMed

    Brockmeyer, Berit; Kraus, Uta R; Theobald, Norbert

    2015-12-01

    Silicone passive samplers have gained an increasing attention as single-phased, practical and robust samplers for monitoring of organic contaminants in the aquatic environment in recent years. However, analytical challenges arise in routine application during the extraction of analytes as silicone oligomers are co-extracted and interfere severely during chemical analyses (e.g. gas chromatographic techniques). In this study, we present a fast, practical pre-cleaning method for silicone passive samplers applying accelerated solvent extraction (ASE) for the removal of silicone oligomers prior to the water deployment (hexane/dichloromethane, 100 °C, 70 min). ASE was also shown to be a very fast (10 min) and efficient extraction method for non-polar contaminants (non-exposed PRC recoveries 66-101 %) sampled by the silicone membrane. For both applications, temperature, extraction time and the solvent used for ASE have been optimized. Purification of the ASE extract was carried out by silica gel and high-pressure liquid size exclusion chromatography (HPLC-SEC). The silicone oligomer content was checked by total reflection X-ray fluorescence spectroscopy (TXRF) in order to confirm the absence of the silicone oligomers prior to analysis of passive sampler extracts. The established method was applied on real silicone samplers from the North- and Baltic Sea and showed no matrix effects during analysis of organic pollutants. Internal laboratory standard recoveries were in the same range for laboratory, transport and exposed samplers (85-126 %). PMID:26289330

  17. Investigation of the entry characteristics of dust samplers of a type used in the British nuclear industry

    NASA Astrophysics Data System (ADS)

    Mark, D.; Vincent, J. H.; Stevens, D. C.; Marshall, M.

    Experiments have been carried out in a large wind tunnel to investigate the entry characteristics of dust samplers—both static and personal—of the type used to monitor 'total' airborne radioactive paniculate in the British nuclear industry. These samplers were exposed to test dusts of closely-graded fused alumina under experimental conditions relevant to the environmental conditions found in nuclear industry workplaces. For the static samplers (60-mm open face filter holders), performance was determined by reference to a 10-mm isokinetic probe. The resultant aspiration efficiency ( A) was found to be close to unity for the range of environmental conditions found in the nuclear industry workplace and for particles with aerodynamic diameter up to about 30 μm. Also it is unaffected by mounting the sampler itself on the large bluff body of the sampling pump. The performances of the personal samplers (of the 25-mm filter holder type) were assessed in terms of the ratio ( R) between the mass of dust entering each personal sampler when worn on the body of a mannequin and that entering the mouth of the mannequin under simulated breathing. The results show that, for nuclear industry workplace conditions, the personal samplers reflect satisfactorily the health-related 'total' dust exposure of the wearer.

  18. Systematic Teaching and Measuring Mathematics "STAMM," Mini-Sampler.

    ERIC Educational Resources Information Center

    Jefferson County Public Schools, Lakewood, CO.

    This booklet contains an overview and a sample of some of the curricular materials developed in Jefferson County's Systematic Teaching and Measuring Mathematics (STAMM) program. It provides continuous progress in mathematics, K-12, using management by objectives. Well-defined processes for diagnosis, instructional activities, and assessment are…

  19. Science Sampler: Enhancing Student Understanding of Physical and Chemical Changes

    ERIC Educational Resources Information Center

    McIntosh, Julie; White, Sandra; Suter, Robert

    2009-01-01

    Students within the Findlay, Ohio, City School District, as well as students across the country, struggle with understanding physical and chemical changes. Therefore, in this article, the authors suggest some standards-based activities to clarify misconceptions and provide formative assessments to measure your students' progress as they determine…

  20. Room temperature synthesis and solid-state structure of Ni{sub 2}P{sub 2}O{sub 6}.12H{sub 2}O

    SciTech Connect

    Haag, J.M.; LeBret, G.C.; Cleary, D.A. . E-mail: cleary@gonzaga.edu; Twamley, B.

    2005-04-15

    The synthesis and crystal structure of Ni{sub 2}P{sub 2}O{sub 6}.12H{sub 2}O are reported. The compound was synthesized from aqueous solutions of nickel chloride and sodium hypodiphosphate at room temperature. The space group is orthorhombic, Pnnm. Unit cell dimensions are a=11.2418(5)A, b=18.5245(8)A, and c=7.3188(3)A, Z=4. The product is unstable with respect to dehydration above room temperature.