Sample records for actual field test

  1. Thermal Performance of Cryogenic Piping Multilayer Insulation in Actual Field Installations

    NASA Technical Reports Server (NTRS)

    Fesmire, J.; Augustnynowicz, S.; Thompson, K. (Technical Monitor)

    2002-01-01

    A standardized way of comparing the thermal performance of different pipelines in different sizes is needed. Vendor data for vacuum-insulated piping are typically given in heat leak rate per unit length (W/m) for a specific diameter pipeline. An overall k-value for actual field installations (k(sub oafi)) is therefore proposed as a more generalized measure for thermal performance comparison and design calculation. The k(sub oafi) provides a direct correspondence to the k-values reported for insulation materials and illustrates the large difference between ideal multilayer insulation (MLI) and actual MLI performance. In this experimental research study, a section of insulated piping was tested under cryogenic vacuum conditions, including simulated spacers and bending. Several different insulation systems were tested using a 1-meter-long cylindrical cryostat test apparatus. The simulated spacers tests showed significant degradation in the thermal performance of a given insulation system. An 18-meter-long pipeline test apparatus is now in operation at the Cryogenics Test Laboratory, NASA Kennedy Space Center, for conducting liquid nitrogen thermal performance tests.

  2. Actual and Virtual Reality: Making the Most of Field Trips.

    ERIC Educational Resources Information Center

    Bellan, Jennifer Marie; Scheurman, Geoffrey

    1998-01-01

    Argues that a virtual field trip can complement and enhance a real one. Discusses the benefits and pitfalls of both types of field trips. Outlines a series of student and teacher activities combining an actual field trip and a virtual one to Fort Snelling in St. Paul, Minnesota. (MJP)

  3. Actual and Recalled Test Anxiety and Flexibility, Rigidity, and Self-Control.

    ERIC Educational Resources Information Center

    DeVito, Anthony J.; Kubis, Joseph F.

    1983-01-01

    Compared recalled and actual test anxiety in college students (N=71) and examined the interrelationship of anxiety with personality variables and sex differences. Results showed recalled test anxiety to be significantly higher than actual test anxiety and indicated no significant differences according to sex. (LLL)

  4. Comprehensive Evaluation of Attitude and Orbit Estimation Using Actual Earth Magnetic Field Data

    NASA Technical Reports Server (NTRS)

    Deutschmann, Julie K.; Bar-Itzhack, Itzhack Y.

    2000-01-01

    A single, augmented Extended Kalman Filter (EKF), which simultaneously and autonomously estimates spacecraft attitude and orbit has been developed and successfully tested with real magnetometer and gyro data only. Because the earth magnetic field is a function of time and position, and because time is known quite precisely, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft orbit, are a function of both orbit and attitude errors. Thus, conceivably these differences could be used to estimate both orbit and attitude; an observability study validated this assumption. The results of testing the EKF with actual magnetometer and gyro data, from four satellites supported by the NASA Goddard Space Flight Center (GSFC) Guidance, Navigation, and Control Center, are presented and evaluated. They confirm the assumption that a single EKF can estimate both attitude and orbit when using gyros and magnetometers only.

  5. 29 CFR 801.24 - Rights of examinee-actual testing phase.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... An examiner may, however, recess the testing phase and return to the pre-test phase to review... examinee and then analyzes the charts derived from the test. Throughout the actual testing phase, the... length. Such “test period” begins at the time that the examiner begins informing the examinee of the...

  6. 29 CFR 801.24 - Rights of examinee-actual testing phase.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... An examiner may, however, recess the testing phase and return to the pre-test phase to review... examinee and then analyzes the charts derived from the test. Throughout the actual testing phase, the... length. Such “test period” begins at the time that the examiner begins informing the examinee of the...

  7. 29 CFR 801.24 - Rights of examinee-actual testing phase.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... An examiner may, however, recess the testing phase and return to the pre-test phase to review... examinee and then analyzes the charts derived from the test. Throughout the actual testing phase, the... length. Such “test period” begins at the time that the examiner begins informing the examinee of the...

  8. 29 CFR 801.24 - Rights of examinee-actual testing phase.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... An examiner may, however, recess the testing phase and return to the pre-test phase to review... examinee and then analyzes the charts derived from the test. Throughout the actual testing phase, the... length. Such “test period” begins at the time that the examiner begins informing the examinee of the...

  9. 29 CFR 801.24 - Rights of examinee-actual testing phase.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... An examiner may, however, recess the testing phase and return to the pre-test phase to review... examinee and then analyzes the charts derived from the test. Throughout the actual testing phase, the... length. Such “test period” begins at the time that the examiner begins informing the examinee of the...

  10. Actual and Idealized Crystal Field Parameterizations for the Uranium Ions in UF 4

    NASA Astrophysics Data System (ADS)

    Gajek, Z.; Mulak, J.; Krupa, J. C.

    1993-12-01

    The crystal field parameters for the actual coordination symmetries of the uranium ions in UF 4, C2 and C1, and for their idealizations to D2, C2 v , D4, D4 d , and the Archimedean antiprism point symmetries are given. They have been calculated by means of both the perturbative ab initio model and the angular overlap model and are referenced to the recent results fitted by Carnall's group. The equivalency of some different sets of parameters has been verified with the standardization procedure. The adequacy of several idealized approaches has been tested by comparison of the corresponding splitting patterns of the 3H 4 ground state. Our results support the parameterization given by Carnall. Furthermore, the parameterization of the crystal field potential and the splitting diagram for the symmetryless uranium ion U( C1) are given. Having at our disposal the crystal field splittings for the two kinds of uranium ions in UF 4, U( C2) and U( C1), we calculate the model plots of the paramagnetic susceptibility χ( T) and the magnetic entropy associated with the Schottky anomaly Δ S( T) for UF 4.

  11. Actual curriculum development practices instrument: Testing for factorial validity

    NASA Astrophysics Data System (ADS)

    Foi, Liew Yon; Bakar, Kamariah Abu; Hamzah, Mohd Sahandri Gani; Alwi, Nor Hayati

    2014-09-01

    The Actual Curriculum Development Practices Instrument (ACDP-I) was developed and the factorial validity of the ACDP-I was tested (n = 107) using exploratory factor analysis procedures in the earlier work of [1]. Despite the ACDP-I appears to be content and construct valid instrument with very high internal reliability qualities for using in Malaysia, the accumulated evidences are still needed to provide a sound scientific basis for the proposed score interpretations. Therefore, the present study addresses this concern by utilising the confirmatory factor analysis to further confirm the theoretical structure of the variable Actual Curriculum Development Practices (ACDP) and enrich the psychometrical properties of ACDP-I. Results of this study have practical implication to both researchers and educators whose concerns focus on teachers' classroom practices and the instrument development and validation process.

  12. Characterization of personal RF electromagnetic field exposure and actual absorption for the general public.

    PubMed

    Joseph, W; Vermeeren, G; Verloock, L; Heredia, Mauricio Masache; Martens, Luc

    2008-09-01

    In this paper, personal electromagnetic field exposure of the general public due to 12 different radiofrequency sources is characterized. Twenty-eight different realistic exposure scenarios based upon time, environment, activity, and location have been defined and a relevant number of measurements were performed with a personal exposure meter. Indoor exposure in office environments can be higher than outdoor exposure: 95th percentiles of field values due to WiFi ranged from 0.36 to 0.58 V m(-1), and for DECT values of 0.33 V m(-1) were measured. The downlink signals of GSM and DCS caused the highest outdoor exposures up to 0.52 V m(-1). The highest total field exposure occurred for mobile scenarios (inside a train or bus) from uplink signals of GSM and DCS (e.g., mobile phones) due to changing environmental conditions, handovers, and higher required transmitted signals from mobile phones due to penetration through windows while moving. A method to relate the exposure to the actual whole-body absorption in the human body is proposed. An application is shown where the actual absorption in a human body model due to a GSM downlink signal is determined. Fiftieth, 95th, and 99 th percentiles of the whole-body specific absorption rate (SAR) due to this GSM signal of 0.58 microW kg(-1), 2.08 microW kg(-1), and 5.01 microW kg(-1) are obtained for a 95th percentile of 0.26 V m(-1). A practical usable function is proposed for the relation between the whole-body SAR and the electric fields. The methodology of this paper enables epidemiological studies to make an analysis in combination with both electric field and actual whole-body SAR values and to compare exposure with basic restrictions.

  13. ACTUAL WASTE TESTING OF GYCOLATE IMPACTS ON THE SRS TANK FARM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martino, C.

    2014-05-28

    Glycolic acid is being studied as a replacement for formic acid in the Defense Waste Processing Facility (DWPF) feed preparation process. After implementation, the recycle stream from DWPF back to the high-level waste Tank Farm will contain soluble sodium glycolate. Most of the potential impacts of glycolate in the Tank Farm were addressed via a literature review and simulant testing, but several outstanding issues remained. This report documents the actual-waste tests to determine the impacts of glycolate on storage and evaporation of Savannah River Site high-level waste. The objectives of this study are to address the following: Determine the extentmore » to which sludge constituents (Pu, U, Fe, etc.) dissolve (the solubility of sludge constituents) in the glycolate-containing 2H-evaporator feed. Determine the impact of glycolate on the sorption of fissile (Pu, U, etc.) components onto sodium aluminosilicate solids. The first objective was accomplished through actual-waste testing using Tank 43H and 38H supernatant and Tank 51H sludge at Tank Farm storage conditions. The second objective was accomplished by contacting actual 2H-evaporator scale with the products from the testing for the first objective. There is no anticipated impact of up to 10 g/L of glycolate in DWPF recycle to the Tank Farm on tank waste component solubilities as investigated in this test. Most components were not influenced by glycolate during solubility tests, including major components such as aluminum, sodium, and most salt anions. There was potentially a slight increase in soluble iron with added glycolate, but the soluble iron concentration remained so low (on the order of 10 mg/L) as to not impact the iron to fissile ratio in sludge. Uranium and plutonium appear to have been supersaturated in 2H-evaporator feed solution mixture used for this testing. As a result, there was a reduction of soluble uranium and plutonium as a function of time. The change in soluble uranium concentration

  14. External Validity of Contingent Valuation: Comparing Hypothetical and Actual Payments.

    PubMed

    Ryan, Mandy; Mentzakis, Emmanouil; Jareinpituk, Suthi; Cairns, John

    2017-11-01

    Whilst contingent valuation is increasingly used in economics to value benefits, questions remain concerning its external validity that is do hypothetical responses match actual responses? We present results from the first within sample field test. Whilst Hypothetical No is always an Actual No, Hypothetical Yes exceed Actual Yes responses. A constant rate of response reversals across bids/prices could suggest theoretically consistent option value responses. Certainty calibrations (verbal and numerical response scales) minimise hypothetical-actual discrepancies offering a useful solution. Helping respondents resolve uncertainty may reduce the discrepancy between hypothetical and actual payments and thus lead to more accurate policy recommendations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. GOCE gravity field simulation based on actual mission scenario

    NASA Astrophysics Data System (ADS)

    Pail, R.; Goiginger, H.; Mayrhofer, R.; Höck, E.; Schuh, W.-D.; Brockmann, J. M.; Krasbutter, I.; Fecher, T.; Gruber, T.

    2009-04-01

    In the framework of the ESA-funded project "GOCE High-level Processing Facility", an operational hardware and software system for the scientific processing (Level 1B to Level 2) of GOCE data has been set up by the European GOCE Gravity Consortium EGG-C. One key component of this software system is the processing of a spherical harmonic Earth's gravity field model and the corresponding full variance-covariance matrix from the precise GOCE orbit and calibrated and corrected satellite gravity gradiometry (SGG) data. In the framework of the time-wise approach a combination of several processing strategies for the optimum exploitation of the information content of the GOCE data has been set up: The Quick-Look Gravity Field Analysis is applied to derive a fast diagnosis of the GOCE system performance and to monitor the quality of the input data. In the Core Solver processing a rigorous high-precision solution of the very large normal equation systems is derived by applying parallel processing techniques on a PC cluster. Before the availability of real GOCE data, by means of a realistic numerical case study, which is based on the actual GOCE orbit and mission scenario and simulation data stemming from the most recent ESA end-to-end simulation, the expected GOCE gravity field performance is evaluated. Results from this simulation as well as recently developed features of the software system are presented. Additionally some aspects on data combination with complementary data sources are addressed.

  16. Environmental assessment of the 40 kilowatt fuel cell system field test operation

    NASA Technical Reports Server (NTRS)

    Bollenbacher, G.

    1982-01-01

    This environmental assessment examines the potential environmental consequences, both adverse and beneficial, of the 40 kW fuel cell system system field test operation. The assessment is of necessity generic in nature since actual test sites were not selected. This assessment provides the basis for determining the need for an environmental impact statement. In addition, this assessment provides siting criteria to avoid or minimize negative environmental impacts and standards for determining candidate test sites, if any, for which site specific assessments may be required.

  17. Photovoltaic performance models: an evaluation with actual field data

    NASA Astrophysics Data System (ADS)

    TamizhMani, Govindasamy; Ishioye, John-Paul; Voropayev, Arseniy; Kang, Yi

    2008-08-01

    Prediction of energy production is crucial to the design and installation of the building integrated photovoltaic systems. This prediction should be attainable based on the commonly available parameters such as system size, orientation and tilt angle. Several commercially available as well as free downloadable software tools exist to predict energy production. Six software models have been evaluated in this study and they are: PV Watts, PVsyst, MAUI, Clean Power Estimator, Solar Advisor Model (SAM) and RETScreen. This evaluation has been done by comparing the monthly, seasonaly and annually predicted data with the actual, field data obtained over a year period on a large number of residential PV systems ranging between 2 and 3 kWdc. All the systems are located in Arizona, within the Phoenix metropolitan area which lies at latitude 33° North, and longitude 112 West, and are all connected to the electrical grid.

  18. Double-blind photo lineups using actual eyewitnesses: an experimental test of a sequential versus simultaneous lineup procedure.

    PubMed

    Wells, Gary L; Steblay, Nancy K; Dysart, Jennifer E

    2015-02-01

    Eyewitnesses (494) to actual crimes in 4 police jurisdictions were randomly assigned to view simultaneous or sequential photo lineups using laptop computers and double-blind administration. The sequential procedure used in the field experiment mimicked how it is conducted in actual practice (e.g., using a continuation rule, witness does not know how many photos are to be viewed, witnesses resolve any multiple identifications), which is not how most lab experiments have tested the sequential lineup. No significant differences emerged in rates of identifying lineup suspects (25% overall) but the sequential procedure produced a significantly lower rate (11%) of identifying known-innocent lineup fillers than did the simultaneous procedure (18%). The simultaneous/sequential pattern did not significantly interact with estimator variables and no lineup-position effects were observed for either the simultaneous or sequential procedures. Rates of nonidentification were not significantly different for simultaneous and sequential but nonidentifiers from the sequential procedure were more likely to use the "not sure" response option than were nonidentifiers from the simultaneous procedure. Among witnesses who made an identification, 36% (41% of simultaneous and 32% of sequential) identified a known-innocent filler rather than a suspect, indicating that eyewitness performance overall was very poor. The results suggest that the sequential procedure that is used in the field reduces the identification of known-innocent fillers, but the differences are relatively small.

  19. Field test of an alternative longwall gate road design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, R.M.; Vandergrift, T.L.; McDonnell, J.P.

    1994-01-01

    The US Bureau of Mines (USBM) MULSIM/ML modeling technique has been used to analyze anticipated stress distributions for a proposed alternative longwall gate road design for a western Colorado coal mine. The model analyses indicated that the alternative gate road design would reduce stresses in the headgate entry. To test the validity of the alternative gate road design under actual mining conditions, a test section of the alternative system was incorporated into a subsequent set of gate roads developed at the mine. The alternative gate road test section was instrumented with borehole pressure cells, as part of an ongoing USBMmore » research project to monitor ground pressure changes as longwall mining progressed. During the excavation of the adjacent longwall panels, the behavior of the alternative gate road system was monitored continuously using the USBM computer-assisted Ground Control Management System. During these field tests, the alternative gate road system was first monitored and evaluated as a headgate, and later monitored and evaluated as a tailgate. The results of the field tests confirmed the validity of using the MULSIM/NL modeling technique to evaluate mine designs.« less

  20. Influence of the magnetic field profile on ITER conductor testing

    NASA Astrophysics Data System (ADS)

    Nijhuis, A.; Ilyin, Y.; ten Kate, H. H. J.

    2006-08-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally

  1. Assessment of actual transpiration rate in olive tree field combining sap-flow, leaf area index and scintillometer measurements

    NASA Astrophysics Data System (ADS)

    Agnese, C.; Cammalleri, C.; Ciraolo, G.; Minacapilli, M.; Provenzano, G.; Rallo, G.; de Bruin, H. A. R.

    2009-09-01

    Models to estimate the actual evapotranspiration (ET) in sparse vegetation area can be fundamental for agricultural water managements, especially when water availability is a limiting factor. Models validation must be carried out by considering in situ measurements referred to the field scale, which is the relevant scale of the modelled variables. Moreover, a particular relevance assumes to consider separately the components of plant transpiration (T) and soil evaporation (E), because only the first is actually related to the crop stress conditions. Objective of the paper was to assess a procedure aimed to estimate olive trees actual transpiration by combining sap flow measurements with the scintillometer technique at field scale. The study area, located in Western Sicily (Italy), is mainly cultivated with olive crop and is characterized by typical Mediterranean semi-arid climate. Measurements of sap flow and crop actual evapotranspiration rate were carried out during 2008 irrigation season. Crop transpiration fluxes, measured on some plants by means of sap flow sensors, were upscaled considering the leaf area index (LAI). The comparison between evapotranspiration values, derived by displaced-beam small-aperture scintillometer (DBSAS-SLS20, Scintec AG), with the transpiration fluxes obtained by the sap flow sensors, also allowed to evaluate the contribute of soil evaporation in an area characterized by low vegetation coverage.

  2. Combustion Safety Simplified Test Protocol Field Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brand, L; Cautley, D.; Bohac, D.

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies onmore » combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.« less

  3. Can test fields destroy the event horizon in the Kerr–Taub–NUT spacetime?

    NASA Astrophysics Data System (ADS)

    Düztaş, Koray

    2018-02-01

    In this work we investigate if the interaction of the Kerr–Taub–NUT spacetime with test scalar and neutrino fields can lead to the destruction of the event horizon. It turns out that both extremal and nearly extremal black holes can be destroyed by scalar and neutrino fields if the initial angular momentum of the spacetime is sufficiently large relative to its mass and NUT charge. This is the first example in which a classical field satisfying the null energy condition can actually destroy an extremal black hole. For scalar fields, the modes that can lead to the destruction of the horizon are restricted to a narrow range due to superradiance. Since superradiance does not occur for neutrino fields, the destruction of the horizon by neutrino fields is generic, and it cannot be fixed by backreaction effects. We also show that the extremal black holes that can be destroyed by scalar fields correspond to naked singularities in the Kerr limit, in accord with the previous results which imply that extremal Kerr black holes cannot be destroyed by scalar test fields.

  4. Sludge batch 9 follow-on actual-waste testing for the nitric-glycolic flowsheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martino, C. J.; Newell, J. D.; Crawford, C. L.

    An actual-waste Sludge Batch 9 qualification run with the nitric-glycolic flowsheet (SC-18) was performed in FY16. In order to supplement the knowledge base for the nitric-glycolic flowsheet, additional testing was performed on the product slurries, condensates, and intermediate samples from run SC-18.

  5. Evidence-based analysis of field testing of medical electrical equipment.

    PubMed

    Taktak, A G; Brown, M C

    2006-01-01

    Field testing of medical electrical equipment remains a topic of debate amongst biomedical engineers. A questionnaire was circulated among members of the main professional body for Medical Engineering Departments in the UK and Ireland and in the Medical Physics and Engineering Mailbase Server. The aim of the questionnaire was to establish consensus on common practice on the frequency and type of safety tests carried out in the field and common sources of hazards and risk management. Twenty-six replies were received in total. A clear majority of 54% of the respondents reported that they carried out safety tests on hospital-based medical equipment on a yearly basis. For other equipment, regular tests were carried out by 58% on loan equipment and by 69% on medical electrical systems. Laboratory equipment on the other hand were not tested in 42% of the cases. Domiciliary and research equipment were only tested in 11% and 15% of the cases respectively. A clear majority of 93% said that they label equipment after tests, 34% said that they always record the actual values (as opposed to pass or fail) and 54% said they carry out functional test as part of the safety test. Although 61% of failures were attributed to the mains lead, only 50% of the respondents said that they had a management system in place for detachable mains leads.

  6. Testing two temporal upscaling schemes for the estimation of the time variability of the actual evapotranspiration

    NASA Astrophysics Data System (ADS)

    Maltese, A.; Capodici, F.; Ciraolo, G.; La Loggia, G.

    2015-10-01

    Temporal availability of grapes actual evapotranspiration is an emerging issue since vineyards farms are more and more converted from rainfed to irrigated agricultural systems. The manuscript aims to verify the accuracy of the actual evapotranspiration retrieval coupling a single source energy balance approach and two different temporal upscaling schemes. The first scheme tests the temporal upscaling of the main input variables, namely the NDVI, albedo and LST; the second scheme tests the temporal upscaling of the energy balance output, the actual evapotranspiration. The temporal upscaling schemes were implemented on: i) airborne remote sensing data acquired monthly during a whole irrigation season over a Sicilian vineyard; ii) low resolution MODIS products released daily or weekly; iii) meteorological data acquired by standard gauge stations. Daily MODIS LST products (MOD11A1) were disaggregated using the DisTrad model, 8-days black and white sky albedo products (MCD43A) allowed modeling the total albedo, and 8-days NDVI products (MOD13Q1) were modeled using the Fisher approach. Results were validated both in time and space. The temporal validation was carried out using the actual evapotranspiration measured in situ using data collected by a flux tower through the eddy covariance technique. The spatial validation involved airborne images acquired at different times from June to September 2008. Results aim to test whether the upscaling of the energy balance input or output data performed better.

  7. Efficient field testing for load rating railroad bridges

    NASA Astrophysics Data System (ADS)

    Schulz, Jeffrey L.; Brett C., Commander

    1995-06-01

    As the condition of our infrastructure continues to deteriorate, and the loads carried by our bridges continue to increase, an ever growing number of railroad and highway bridges require load limits. With safety and transportation costs at both ends of the spectrum. the need for accurate load rating is paramount. This paper describes a method that has been developed for efficient load testing and evaluation of short- and medium-span bridges. Through the use of a specially-designed structural testing system and efficient load test procedures, a typical bridge can be instrumented and tested at 64 points in less than one working day and with minimum impact on rail traffic. Various techniques are available to evaluate structural properties and obtain a realistic model. With field data, a simple finite element model is 'calibrated' and its accuracy is verified. Appropriate design and rating loads are applied to the resulting model and stress predictions are made. This technique has been performed on numerous structures to address specific problems and to provide accurate load ratings. The merits and limitations of this approach are discussed in the context of actual examples of both rail and highway bridges that were tested and evaluated.

  8. Hydrogen Field Test Standard: Laboratory and Field Performance

    PubMed Central

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give

  9. LSA field test

    NASA Technical Reports Server (NTRS)

    Jaffe, P.

    1979-01-01

    Degradation tests indicate that electrical degradation is not a slow monotonically increasing phenomenon as originally thought but occurs abruptly as the result of some traumatic event. This finding has led to a change in the test philosophy. A discussion of this change is presented along with a summary of degradation and failure data from all the sites and results from a variety of special tests. New instrumentation for in-field measurements are described. Field testing activity was expanded by the addition of twelve remote sites located as far away as Alaska and the Canal Zone. Descriptions of the new sites are included.

  10. Monitoring based maintenance utilizing actual stress sensory technology

    NASA Astrophysics Data System (ADS)

    Sumitro, Sunaryo; Kurokawa, Shoji; Shimano, Keiji; Wang, Ming L.

    2005-06-01

    In recent years, many infrastructures have been deteriorating. In order to maintain sustainability of those infrastructures which have significant influence on social lifelines, economical and rational maintenance management should be carried out to evaluate the life cycle cost (LCC). The development of structural health monitoring systems, such as deriving evaluation techniques for the field structural condition of existing structures and identification techniques for the significant engineering properties of new structures, can be considered as the first step in resolving the above problem. New innovative evaluation methods need to be devised to identify the deterioration of infrastructures, e.g. steel tendons, cables in cable-stayed bridges and strands embedded in pre- or post-tensioned concrete structures. One of the possible solutions that show 'AtoE' characteristics, i.e., (a)ccuracy, (b)enefit, (c)ompendiousness, (d)urability and (e)ase of operation, elasto-magnetic (EM) actual stress sensory technology utilizing the sensitivity of incremental magnetic permeability to stress change, has been developed. Numerous verification tests on various steel materials have been conducted. By comparing with load cell, strain gage and other sensory technology measurement results, the actual stresses of steel tendons in a pre-stressed concrete structure at the following stages have been thoroughly investigated: (i) pre-stress change due to set-loss (anchorage slippage) at the tendon fixation stage; (ii) pre-stress change due to the tendon relaxation stage; (iii) concrete creep and shrinkage at the long term pre-stressing stage; (iv) pre-stress change in the cyclic fatigue loading stage; and (v) pre-stress change due to the re-pre-stress setting stage. As the result of this testing, it is confirmed that EM sensory technology enables one to measure actual stress in steel wire, strands and steel bars precisely without destroying the polyethylene covering sheath and enables

  11. Comparing the effects of oxazepam and diazepam in actual highway driving and neurocognitive test performance: a validation study.

    PubMed

    Jongen, S; Vuurman, E F P M; Ramaekers, J G; Vermeeren, A

    2018-04-01

    Screening of drug-induced performance impairment is needed to provide meaningful information for users and prescribers regarding the impact of drugs on driving. The main objective was to assess the effects of oxazepam 10 mg (OXA10), oxazepam 30 mg (OXA30), and diazepam 10 mg (DIA10) on standard deviation of lateral position (SDLP) in a highway driving test in actual traffic and to determine the ability of eight neurocognitive tests to detect comparable effects. Twenty-three healthy volunteers participated in a four-way double-blind, placebo-controlled, crossover study. The highway driving test was conducted between 4 and 5 h after drug intake. A range of neurocognitive tests was conducted before and after driving, 2 and 6 h post-treatment, respectively. Mean SDLP increased by 1.83, 3.03, and 7.57 cm after OXA10, DIA10, and OXA30, respectively. At 2 h post-treatment, all neurocognitive tests, except the useful field of view, showed performance impairment in all active treatments. Effect sizes (ES) were moderate for OXA10, large ES for DIA10, and largest ES for OXA30. Modest correlations were found between changes in SDLP and performance in the attention network test (ANT), the divided attention test (DAT), and the psychomotor vigilance test (PVT). OXA10 caused minor, DIA10 moderate, and OXA30 severe driving impairment. No neurocognitive test was both dose dependently sensitive and able to be associated with driving impairment. No neurocognitive test can replace the on-the-road highway driving test.

  12. Field Tests of Optical Instruments

    DTIC Science & Technology

    1947-03-15

    s > S3KS55Ü j.6),&;i.r..fc..’.w.~— * s1 Field Tests of Optical Instruments ^. (Not known) (Same) Bureau of Ordnance. Washington, D..D...a large-scale field test of optical instruments are described. The tests were instituted to check the correctness of theoretical considerations and...of laboratory tests -which have been v.sed in the selection and design of such instruments. Field con- ditions approximated as far as possible those

  13. Pilot Field Test Study

    NASA Technical Reports Server (NTRS)

    Sherriff, Abigail

    2015-01-01

    The Field Test study is currently in full swing, preceded by the successful completion of the Pilot Field Test study that paved the way for collecting data on the astronauts in the medical tent in Kazakhstan. Abigail Sherriff worked alongside Logan Dobbe on one Field Test aspect to determine foot clearance over obstacles (5cm, 10cm, and 15cm) using APDM Inc. Internal Measurement Units (IMU) worn by the astronauts. They created a program to accurately calculate foot clearance using the accelerometer, magnetometer, and gyroscope data with the IMUs attached to the top of the shoes. To validate the functionality of their program, they completed a successful study on test subjects performing various tasks in an optical motion studio, considered a gold standard in biomechanics research. Future work will include further validation and expanding the program to include other analyses.

  14. Final Report. LAW Glass Formulation to Support AP-101 Actual Waste Testing, VSL-03R3470-2, Rev. 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muller, I. S.; Pegg, I. L.; Rielley, Elizabeth

    2015-06-22

    The main objective of the work was to develop and select a glass formulation for vitrification testing of the actual waste sample of LAW AP-101 at Battelle - Pacific Northwest Division (PNWD). Other objectives of the work included preparation and characterization of glasses to demonstrate compliance with contract and processing requirements, evaluation of the ability to achieve waste loading requirements, testing to demonstrate compatibility of the glass melts with melter materials of construction, comparison of the properties of simulant and actual waste glasses, and identification of glass formulation issues with respect to contract specifications and processing requirements.

  15. The four-meter confrontation visual field test.

    PubMed Central

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests. PMID:1494829

  16. The four-meter confrontation visual field test.

    PubMed

    Kodsi, S R; Younge, B R

    1992-01-01

    The 4-m confrontation visual field test has been successfully used at the Mayo Clinic for many years in addition to the standard 0.5-m confrontation visual field test. The 4-m confrontation visual field test is a test of macular function and can identify small central or paracentral scotomas that the examiner may not find when the patient is tested only at 0.5 m. Also, macular sparing in homonymous hemianopias and quadrantanopias may be identified with the 4-m confrontation visual field test. We recommend use of this confrontation visual field test, in addition to the standard 0.5-m confrontation visual field test, on appropriately selected patients to obtain the most information possible by confrontation visual field tests.

  17. Flow visualization methods for field test verification of CFD analysis of an open gloveport

    DOE PAGES

    Strons, Philip; Bailey, James L.

    2017-01-01

    Anemometer readings alone cannot provide a complete picture of air flow patterns at an open gloveport. Having a means to visualize air flow for field tests in general provides greater insight by indicating direction in addition to the magnitude of the air flow velocities in the region of interest. Furthermore, flow visualization is essential for Computational Fluid Dynamics (CFD) verification, where important modeling assumptions play a significant role in analyzing the chaotic nature of low-velocity air flow. A good example is shown Figure 1, where an unexpected vortex pattern occurred during a field test that could not have been measuredmore » relying only on anemometer readings. Here by, observing and measuring the patterns of the smoke flowing into the gloveport allowed the CFD model to be appropriately updated to match the actual flow velocities in both magnitude and direction.« less

  18. Field tests of a handheld laser communications/position-finding binocular system

    NASA Astrophysics Data System (ADS)

    Chan, Victor J.; Rivers, Michael D.; Harris, Amy L.

    1998-01-01

    Lasers provide a means for transmitting larger quantities of data at higher rates than conventional radio frequency devices and can be utilized during radio silent operations on the battle field. A forward scout needs to be able to observe the positions of various targets and relay that information back to a tactical operations command center in a covert manner. The BiCom device built by Trex Communications provides laser ranging, azimuth and elevation angle to a target, GPS position information, data storage and transmit capability, and full duplex audio transmission capability, all in a 3 kg hand held package. The communication channel utilizes an eye safe lasercom transceiver for covert voice or data transfer at 100 kbps at distances of up to 5 km. The information gathered electronically by the unit is sufficient to calculate the actual GPS positions or military grid coordinates of the observed targets. Several dozen targets can be stored in memory for later transmission via lasercom. Field tests were conducted by US Army personnel to evaluate these units and compare the results with conventional means of target position determination and data transfer. A description of the system and results of these tests are presented.

  19. Planned versus actual outcomes as a result of animal feeding operation decisions for managing phosphorus.

    PubMed

    Cabot, Perry E; Nowak, Pete

    2005-01-01

    The paper explores how decisions made on animal feeding operations (AFOs) influence the management of manure and phosphorus. Variability among these decisions from operation to operation and from field to field can influence the validity of nutrient loss risk assessments. These assessments are based on assumptions that the decision outcomes regarding manure distribution will occur as they are planned. The discrepancy between planned versus actual outcomes in phosphorus management was explored on nine AFOs managing a contiguous set of 210 fields in south-central Wisconsin. A total of 2611 soil samples were collected and multiple interviews conducted to assign phosphorus index (PI) ratings to the fields. Spearman's rank correlation coefficients (r(S)) indicated that PI ratings were less sensitive to soil test phosphorus (STP) levels (r(S) = 0.378), universal soil loss equation (USLE) (r(S) = 0.261), ratings for chemical fertilizer application (r(S) = 0.185), and runoff class (r(S) = -0.089), and more sensitive to ratings for manure application (r(S) = 0.854). One-way ANOVA indicated that mean field STP levels were more homogenous than field PI ratings between AFOs. Kolmogorov-Smirnov (K-S) tests displayed several nonsignificant comparisons for cumulative distribution functions, S(x), of mean STP levels on AFO fields. On the other hand, the K-S tests of S(x) for PI ratings indicated that the majority of these S(x) functions were significantly different between AFOs at or greater than the 0.05 significance level. Interviews suggested multiple reasons for divergence between planned and actual outcomes in managing phosphorus, and that this divergence arises at the strategic, tactical, and operational levels of decision-making.

  20. Comparing Perceptions with Actual Reports of Close Friend's HIV Testing Behavior Among Urban Tanzanian Men.

    PubMed

    Mulawa, Marta; Yamanis, Thespina J; Balvanz, Peter; Kajula, Lusajo J; Maman, Suzanne

    2016-09-01

    Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men's uptake of testing by correcting misperceptions about testing norms, we compare men's perceptions of their closest friend's HIV testing behaviors with the friend's actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men's HIV testing.

  1. The current and future status of the concealed information test for field use.

    PubMed

    Matsuda, Izumi; Nittono, Hiroshi; Allen, John J B

    2012-01-01

    The Concealed Information Test (CIT) is a psychophysiological technique for examining whether a person has knowledge of crime-relevant information. Many laboratory studies have shown that the CIT has good scientific validity. However, the CIT has seldom been used for actual criminal investigations. One successful exception is its use by the Japanese police. In Japan, the CIT has been widely used for criminal investigations, although its probative force in court is not strong. In this paper, we first review the current use of the field CIT in Japan. Then, we discuss two possible approaches to increase its probative force: sophisticated statistical judgment methods and combining new psychophysiological measures with classic autonomic measures. On the basis of these considerations, we propose several suggestions for future practice and research involving the field CIT.

  2. The Current and Future Status of the Concealed Information Test for Field Use

    PubMed Central

    Matsuda, Izumi; Nittono, Hiroshi; Allen, John J. B.

    2012-01-01

    The Concealed Information Test (CIT) is a psychophysiological technique for examining whether a person has knowledge of crime-relevant information. Many laboratory studies have shown that the CIT has good scientific validity. However, the CIT has seldom been used for actual criminal investigations. One successful exception is its use by the Japanese police. In Japan, the CIT has been widely used for criminal investigations, although its probative force in court is not strong. In this paper, we first review the current use of the field CIT in Japan. Then, we discuss two possible approaches to increase its probative force: sophisticated statistical judgment methods and combining new psychophysiological measures with classic autonomic measures. On the basis of these considerations, we propose several suggestions for future practice and research involving the field CIT. PMID:23205018

  3. Anxiety in visual field testing.

    PubMed

    Chew, Shenton S L; Kerr, Nathan M; Wong, Aaron B C; Craig, Jennifer P; Chou, Chi-Ying; Danesh-Meyer, Helen V

    2016-08-01

    To determine if Humphrey visual field (HVF) testing induces anxiety and how anxiety relates to visual field parameters of reliability and severity. A prospective cohort study at a university affiliated private ophthalmic practice. 137 consecutive age-matched and gender-matched patients with glaucoma undergoing either HVF testing only (n=102) or Heidelberg retinal tomography (HRT) only (n=35) were enrolled. Prior to testing, participants completed the State-Trait Anxiety Inventory questionnaire. A 5-point Likert scale was used to grade pretest anxiety and was repeated after testing to grade intratest anxiety. Subjective discomfort parameters were also recorded. Anxiety scores were used to make non-parametrical comparisons and correlations between cohorts and also against visual field reliability and severity indices. Trait anxiety (p=0.838) and pretest anxiety (p=0.802) were not significantly different between test groups. Within the HVF group, intratest anxiety was 1.2 times higher than pretest anxiety (p=0.0001), but was not significantly different in the HRT group (p=0.145). Pretest anxiety was correlated with test unreliability (Spearman's r=0.273, p=0.006), which was predictive of worse test severity (p=0.0027). Subjects who had undergone more than 10 visual field tests had significantly lower pretest and intratest anxiety levels than those who had not (p=0.0030 and p=0.0004, respectively). HVF testing induces more anxiety than HRT. Increased pretest anxiety may reduce HVF test reliability. Increased test experience or interventions aimed at reducing pretest anxiety may result in improved test reliability and accuracy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Open-field test site

    NASA Astrophysics Data System (ADS)

    Gyoda, Koichi; Shinozuka, Takashi

    1995-06-01

    An open-field test site with measurement equipment, a turn table, antenna positioners, and measurement auxiliary equipment was remodelled at the CRL north-site. This paper introduces the configuration, specifications and characteristics of this new open-field test site. Measured 3-m and 10-m site attenuations are in good agreement with theoretical values, and this means that this site is suitable for using 3-m and 10-m method EMI/EMC measurements. The site is expected to be effective for antenna measurement, antenna calibration, and studies on EMI/EMC measurement methods.

  5. Comparing Perceptions with Actual Reports of Close Friend’s HIV Testing Behavior Among Urban Tanzanian Men

    PubMed Central

    Yamanis, Thespina J.; Balvanz, Peter; Kajula, Lusajo J.; Maman, Suzanne

    2016-01-01

    Men have lower rates of HIV testing and higher rates of AIDS-related mortality compared to women in sub-Saharan Africa. To assess whether there is an opportunity to increase men’s uptake of testing by correcting misperceptions about testing norms, we compare men’s perceptions of their closest friend’s HIV testing behaviors with the friend’s actual testing self-report using a unique dataset of men sampled within their social networks (n = 59) in Dar es Salaam, Tanzania. We examine the accuracy and bias of perceptions among men who have tested for HIV (n = 391) and compare them to the perceptions among men who never tested (n = 432). We found that testers and non-testers did not differ in the accuracy of their perceptions, though non-testers were strongly biased towards assuming that their closest friends had not tested. Our results lend support to social norms approaches designed to correct the biased misperceptions of non-testers to promote men’s HIV testing. PMID:26880322

  6. The actual citation impact of European oncological research.

    PubMed

    López-Illescas, Carmen; de Moya-Anegón, Félix; Moed, Henk F

    2008-01-01

    This study provides an overview of the research performance of major European countries in the field Oncology, the most important journals in which they published their research articles, and the most important academic institutions publishing them. The analysis was based on Thomson Scientific's Web of Science (WoS) and calculated bibliometric indicators of publication activity and actual citation impact. Studying the time period 2000-2006, it gives an update of earlier studies, but at the same time it expands their methodologies, using a broader definition of the field, calculating indicators of actual citation impact, and analysing new and policy relevant aspects. Findings suggest that the emergence of Asian countries in the field Oncology has displaced European articles more strongly than articles from the USA; that oncologists who have published their articles in important, more general journals or in journals covering other specialties, rather than in their own specialist journals, have generated a relatively high actual citation impact; and that universities from Germany, and--to a lesser extent--those from Italy, the Netherlands, UK, and Sweden, dominate a ranking of European universities based on number of articles in oncology. The outcomes illustrate that different bibliometric methodologies may lead to different outcomes, and that outcomes should be interpreted with care.

  7. SELF-ACTUALIZATION AND THE UTILIZATION OF TALENT.

    ERIC Educational Resources Information Center

    FRENCH, JOHN R.P.; MILLER, DANIEL R.

    THIS STUDY ATTEMPTED (1) TO DEVELOP A THEORY OF THE CAUSES AND CONSEQUENCES OF SELF-ACTUALIZATION AS RELATED TO THE UTILIZATION OF TALENT, (2) TO FIT THE THEORY TO EXISTING DATA, AND (3) TO PLAN ONE OR MORE RESEARCH PROJECTS TO TEST THE THEORY. TWO ARTICLES ON IDENTITY AND MOTIVATION AND SELF-ACTUALIZATION AND SELF-IDENTITY THEORY REPORTED THE…

  8. Useful field of view test.

    PubMed

    Wood, Joanne M; Owsley, Cynthia

    2014-01-01

    The useful field of view test was developed to reflect the visual difficulties that older adults experience with everyday tasks. Importantly, the useful field of view test (UFOV) is one of the most extensively researched and promising predictor tests for a range of driving outcomes measures, including driving ability and crash risk as well as other everyday tasks. Currently available commercial versions of the test can be administered using personal computers; these measure the speed of visual processing for rapid detection and localization of targets under conditions of divided visual attention and in the presence and absence of visual clutter. The test is believed to assess higher-order cognitive abilities, but performance also relies on visual sensory function because in order for targets to be attended to, they must be visible. The format of the UFOV has been modified over the years; the original version estimated the spatial extent of useful field of view, while the latest version measures visual processing speed. While deficits in the useful field of view are associated with functional impairments in everyday activities in older adults, there is also emerging evidence from several research groups that improvements in visual processing speed can be achieved through training. These improvements have been shown to reduce crash risk, and can have a positive impact on health and functional well-being, with the potential to increase the mobility and hence the independence of older adults. © 2014 S. Karger AG, Basel

  9. Field testing a soil site field guide for Allegheny hardwoods

    Treesearch

    S.B. Jones

    1991-01-01

    A site quality evaluation decision model, developed for Allegheny hardwoods on the non-glaciated Allegheny Plateau of Pennsylvania and New York, was field tested by International Paper (IP) foresters and the author, on sites within the region of derivation and on glaciated sites north and west of the Wisconsin drift line. Results from the field testing are presented...

  10. A laboratory and field evaluation of a portable immunoassay test for triazine herbicides in environmental water samples

    USGS Publications Warehouse

    Schulze, P.A.; Capel, P.D.; Squillace, P.J.; Helsel, D.R.

    1993-01-01

    The usefulness and sensitivity, of a portable immunoassay test for the semiquantitative field screening of water samples was evaluated by means of laboratory and field studies. Laboratory results indicated that the tests were useful for the determination of atrazine concentrations of 0.1 to 1.5 μg/L. At a concentration of 1 μg/L, the relative standard deviation in the difference between the regression line and the actual result was about 40 percent. The immunoassay was less sensitive and produced similar errors for other triazine herbicides. After standardization, the test results were relatively insensitive to ionic content and variations in pH (range, 4 to 10), mildly sensitive to temperature changes, and quite sensitive to the timing of the final incubation step, variances in timing can be a significant source of error. Almost all of the immunoassays predicted a higher atrazine concentration in water samples when compared to results of gas chromatography. If these tests are used as a semiquantitative screening tool, this tendency for overprediction does not diminish the tests' usefulness. Generally, the tests seem to be a valuable method for screening water samples for triazine herbicides.

  11. Fault Tree Based Diagnosis with Optimal Test Sequencing for Field Service Engineers

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; George, Laurence L.; Patterson-Hine, F. A.; Lum, Henry, Jr. (Technical Monitor)

    1994-01-01

    When field service engineers go to customer sites to service equipment, they want to diagnose and repair failures quickly and cost effectively. Symptoms exhibited by failed equipment frequently suggest several possible causes which require different approaches to diagnosis. This can lead the engineer to follow several fruitless paths in the diagnostic process before they find the actual failure. To assist in this situation, we have developed the Fault Tree Diagnosis and Optimal Test Sequence (FTDOTS) software system that performs automated diagnosis and ranks diagnostic hypotheses based on failure probability and the time or cost required to isolate and repair each failure. FTDOTS first finds a set of possible failures that explain exhibited symptoms by using a fault tree reliability model as a diagnostic knowledge to rank the hypothesized failures based on how likely they are and how long it would take or how much it would cost to isolate and repair them. This ordering suggests an optimal sequence for the field service engineer to investigate the hypothesized failures in order to minimize the time or cost required to accomplish the repair task. Previously, field service personnel would arrive at the customer site and choose which components to investigate based on past experience and service manuals. Using FTDOTS running on a portable computer, they can now enter a set of symptoms and get a list of possible failures ordered in an optimal test sequence to help them in their decisions. If facilities are available, the field engineer can connect the portable computer to the malfunctioning device for automated data gathering. FTDOTS is currently being applied to field service of medical test equipment. The techniques are flexible enough to use for many different types of devices. If a fault tree model of the equipment and information about component failure probabilities and isolation times or costs are available, a diagnostic knowledge base for that device can be

  12. Actual Condition of Paddy Field Levee Maintenance by Various Farm Households including Large-scale Farming in the Developed Land Renting Area

    NASA Astrophysics Data System (ADS)

    Sakata, Yasuyo

    The survey of interview, resource acquisition, photographic operation, and questionnaire were carried out in the “n” Community in the “y” District in Hakusan City in Ishikawa Prefecture to investigate the actual condition of paddy field levee maintenance in the area where land-renting market was proceeding, large-scale farming was dominant, and the problems of geographically scattered farm-land existed. In the study zone, 1) an agricultural production legal person rent-cultivated some of the paddy fields and maintained the levees, 2) another agricultural production legal person rent-cultivated some of the soy bean fields for crop changeover and land owners maintained the levees. The results indicated that sufficient maintenance was executed on the levees of the paddy fields cultivated by the agricultural production legal person, the soy bean fields for crop changeover, and the paddy fields cultivated by the land owners. Each reason is considered to be the managerial strategy, the economic incentive, the mutual monitoring and cross-regulatory mechanism, etc.

  13. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE PAGES

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    2017-10-24

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating

  14. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating

  15. Analyzing Educational Testing Service Graduate Major Field Test Results

    ERIC Educational Resources Information Center

    Thornton, Barry; Arbogast, Gordon

    2012-01-01

    The Educational Testing Service (ETS) created the Graduate Major Field Test in Business (GMFT-B) for MBA students. This test is administered to all MBA classes at Jacksonville University for the purpose of measuring student academic achievement and growth, as well as to assess educational outcomes. The test is given in the capstone course,…

  16. 47 CFR 73.1515 - Special field test authorizations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Special field test authorizations. 73.1515 Section 73.1515 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1515 Special field test authorizations. (a) A special field test...

  17. 47 CFR 73.1515 - Special field test authorizations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Special field test authorizations. 73.1515 Section 73.1515 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1515 Special field test authorizations. (a) A special field test...

  18. Trip Report-Produced-Water Field Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Enid J.

    2012-05-25

    Los Alamos National Laboratory (LANL) conducted field testing of a produced-water pretreatment apparatus with assistance from faculty at the Texas A&M University (TAMU) protein separation sciences laboratory located on the TAMU main campus. The following report details all of the logistics surrounding the testing. The purpose of the test was to use a new, commercially-available filter media housing containing modified zeolite (surfactant-modified zeolite or SMZ) porous medium for use in pretreatment of oil and gas produced water (PW) and frac-flowback waters. The SMZ was tested previously in October, 2010 in a lab-constructed configuration ('old multicolumn system'), and performed well formore » removal of benzene, toluene, ethylbenzene, and xylenes (BTEX) from PW. However, a less-expensive, modular configuration is needed for field use. A modular system will allow the field operator to add or subtract SMZ filters as needed to accommodate site specific conditions, and to swap out used filters easily in a multi-unit system. This test demonstrated the use of a commercial filter housing with a simple flow modification and packed with SMZ for removing BTEX from a PW source in College Station, Texas. The system will be tested in June 2012 at a field site in Pennsylvania for treating frac-flowback waters. The goals of this test are: (1) to determine sorption efficiency of BTEX in the new configuration; and (2) to observe the range of flow rates, backpressures, and total volume treated at a given flow rate.« less

  19. Termiticide Field Tests - 1989 Update

    Treesearch

    Bradford M. Kard; Joe K. Mauldin

    1993-01-01

    For several years, organophosphate and pyrethroid termiticides have undergone field evaluation as treatments to soil for control of subterranean termites. These termiticides remained effective at some application rates for 5 or more years. Field data are reported for ground-board and concrete slab tests at sites in the continental United States. Generally, pyrethroids...

  20. Descent advisor preliminary field test

    NASA Technical Reports Server (NTRS)

    Green, Steven M.; Vivona, Robert A.; Sanford, Beverly

    1995-01-01

    A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were to evaluate the accuracy of DA trajectory predictions for conventional- and flight-management-system-equipped jet transports, to identify significant sources of trajectory prediction error, and to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 sec late with a standard deviation of 13.1 sec. This paper describes the field test and presents preliminary results for the commercial flights.

  1. Descent Advisor Preliminary Field Test

    NASA Technical Reports Server (NTRS)

    Green, Steven M.; Vivona, Robert A.; Sanford, Beverly

    1995-01-01

    A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were: (1) to evaluate the accuracy of DA trajectory predictions for conventional and flight-management system equipped jet transports, (2) to identify significant sources of trajectory prediction error, and (3) to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 seconds late with a standard deviation of 13.1 seconds. This paper describes the field test and presents preliminary results for the commercial flights.

  2. Whiteheadian Actual Entitities and String Theory

    NASA Astrophysics Data System (ADS)

    Bracken, Joseph A.

    2012-06-01

    In the philosophy of Alfred North Whitehead, the ultimate units of reality are actual entities, momentary self-constituting subjects of experience which are too small to be sensibly perceived. Their combination into "societies" with a "common element of form" produces the organisms and inanimate things of ordinary sense experience. According to the proponents of string theory, tiny vibrating strings are the ultimate constituents of physical reality which in harmonious combination yield perceptible entities at the macroscopic level of physical reality. Given that the number of Whiteheadian actual entities and of individual strings within string theory are beyond reckoning at any given moment, could they be two ways to describe the same non-verifiable foundational reality? For example, if one could establish that the "superject" or objective pattern of self- constitution of an actual entity vibrates at a specific frequency, its affinity with the individual strings of string theory would be striking. Likewise, if one were to claim that the size and complexity of Whiteheadian 'societies" require different space-time parameters for the dynamic interrelationship of constituent actual entities, would that at least partially account for the assumption of 10 or even 26 instead of just 3 dimensions within string theory? The overall conclusion of this article is that, if a suitably revised understanding of Whiteheadian metaphysics were seen as compatible with the philosophical implications of string theory, their combination into a single world view would strengthen the plausibility of both schemes taken separately. Key words: actual entities, subject/superjects, vibrating strings, structured fields of activity, multi-dimensional physical reality.

  3. Predicting psychopharmacological drug effects on actual driving performance (SDLP) from psychometric tests measuring driving-related skills.

    PubMed

    Verster, Joris C; Roth, Thomas

    2012-03-01

    There are various methods to examine driving ability. Comparisons between these methods and their relationship with actual on-road driving is often not determined. The objective of this study was to determine whether laboratory tests measuring driving-related skills could adequately predict on-the-road driving performance during normal traffic. Ninety-six healthy volunteers performed a standardized on-the-road driving test. Subjects were instructed to drive with a constant speed and steady lateral position within the right traffic lane. Standard deviation of lateral position (SDLP), i.e., the weaving of the car, was determined. The subjects also performed a psychometric test battery including the DSST, Sternberg memory scanning test, a tracking test, and a divided attention test. Difference scores from placebo for parameters of the psychometric tests and SDLP were computed and correlated with each other. A stepwise linear regression analysis determined the predictive validity of the laboratory test battery to SDLP. Stepwise regression analyses revealed that the combination of five parameters, hard tracking, tracking and reaction time of the divided attention test, and reaction time and percentage of errors of the Sternberg memory scanning test, together had a predictive validity of 33.4%. The psychometric tests in this test battery showed insufficient predictive validity to replace the on-the-road driving test during normal traffic.

  4. Field-Based Video Pre-Test Counseling, Oral Testing, and Telephonic Post-Test Counseling: Implementation of an HIV Field Testing Package among High-Risk Indian Men

    ERIC Educational Resources Information Center

    Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.

    2012-01-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling…

  5. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  6. Field tests of a chemiresistor sensor for in-situ monitoring of vapor-phase contaminants

    NASA Astrophysics Data System (ADS)

    Ho, C.; McGrath, L.; Wright, J.

    2003-04-01

    An in-situ chemiresistor sensor has been developed that can detect volatile organic compounds in subsurface environmental applications. Several field tests were conducted in 2001 and 2002 to test the reliability, operation, and performance of the in-situ chemiresistor sensor system. The chemiresistor consists of a carbon-loaded polymer deposited onto a microfabricated circuit. The polymer swells reversibly in the presence of volatile organic compounds as vapor-phase molecules absorb into the polymer, causing a change in the electrical resistance of the circuit. The change in resistance can be calibrated to known concentrations of analytes, and arrays of chemiresistors can be used on a single chip to aid in discrimination. A waterproof housing was constructed to allow the chemiresistor to be used in a variety of media including air, soil, and water. The integrated unit, which can be buried in soils or emplaced in wells, is connected via cable to a surface-based solar-powered data logger. A cell-phone modem is used to automatically download the data from the data logger on a periodic basis. The field tests were performed at three locations: (1) Edwards Air Force Base, CA; (2) Nevada Test Site; and (3) Sandia's Chemical Waste Landfill near Albuquerque, NM. The objectives of the tests were to evaluate the ruggedness, longevity, operation, performance, and engineering requirements of these sensors in actual field settings. Results showed that the sensors could be operated continuously for long periods of time (greater than a year) using remote solar-powered data-logging stations with wireless telemetry. The sensor housing, which was constructed of 304 stainless steel, showed some signs of corrosion when placed in contaminated water for several months, but the overall integrity was maintained. The detection limits of the chemiresistors were generally found to be near 0.1% of the saturated vapor pressure of the target analyte in controlled laboratory conditions (e

  7. Natural and Artificial Playing Fields: Characteristics and Safety Features.

    ERIC Educational Resources Information Center

    Schmidt, Roger C., Ed.; Hoerner, Earl F., Ed.; Milner, Edward M., Ed.; Morehouse, C. A., Ed.

    These papers are on the subjects of playing field standards, surface traction, testing and correlation to actual field experience, and state-of-the-art natural and artificial surfaces. The papers, presented at the Symposium on the Characteristics and Safety of Playing Surfaces (Artificial and Natural) for Field Sports in 1998, cover the…

  8. Termiticide field test report: New termiticides & emerging technologies

    Treesearch

    Bradford M. Kard

    2000-01-01

    Testing at our nationwide field sites detemines the years-of-effectiveness of currently marketed and potentially new termiticides as treatments to soil under long-term field conditions. Several new termiticide candidates and formulations have been placed in the field during the past four years and will be reported on after they complete five years of testing.

  9. Field Testing of Electronic Registering Fareboxes

    DOT National Transportation Integrated Search

    1987-02-01

    This report presents the findings of an evaluation of electronic registering fareboxes in field testing at the Detroit Department of Transportation. Thirty-two fareboxes were tested on one bus route, Woodward Avenue, which was selected because it gen...

  10. Field testing of fugitive dust control techniques at a uranium mill tailings pile - 1982 Field Test, Gas Hills, Wyoming.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elmore, M.R.; Hartley, J.N.

    A field test was conducted on a uranium tailings pile to evaluate the effectiveness of 15 chemical stabilizers for control of fugitive dust from uranium mill tailings. A tailings pile at the Federal American Partners (FAP) Uranium Mill, Gas Hills, Wyoming, was used for the field test. Preliminary laboratory tests using a wing tunnel were conducted to select the more promising stabilizers for field testing. Fourteen of the chemical stabilizers were applied with a field spray system pulled behind a tractor; one--Hydro Mulch--was applied with a hydroseeder. A portable weather station and data logger were installed to record the weathermore » conditions at the test site. After 1 year of monitoring (including three site visits), all of the stabilizers have degraded to some degree; but those applied at the manufacturers' recommended rate are still somewhat effective in reducing fugitive emissions. The following synthetic polymer emulsions appear to be the more effective stabilizers: Wallpol 40-133 from Reichold Chemicals, SP-400 from Johnson and March Corporation, and CPB-12 from Wen Don Corporation. Installed costs for the test plots ranged from $8400 to $11,300/ha; this range results from differences in stabilizer costs. Large-scale stabilization costs of the test materials are expected to range from $680 to $3600/ha based on FAP experience. Evaluation of the chemical stabilizers will continue for approximately 1 year. 2 references, 33 figures, 22 tables.« less

  11. Mechanical testing and development of the helical field coil joint for the Advanced Toroidal Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, B.E.; Bryan, W.E.; Goranson, P.L.

    1985-01-01

    The helical field (HF) coil set for the Advanced Toroidal Facility (ATF) is an M = 12, l = 2, constant-ratio torsatron winding consisting of 2 coils, each with 14 turns of heavy copper conductor. The coils are divided into 24 identical segments to facilitate fabrication and minimize the assembly schedule. The segments are connected across through-bolted lap joints that must carry up to 124,000 A per turn for 5 s or 62,500 A steady-state. In addition, the joints must carry the high magnetic and thermal loads induced in the conductor and still fit within the basic 140- by 30-mmmore » copper envelope. Extensive testing and development were undertaken to verify and refine the basic joint design. Tests included assembly force and clamping force for various types of misalignment; joint resistance as a function of clamping force; clamp bolt relaxation due to thermal cycling; fatigue testing of full-size, multiturn joint prototypes; and low-cycle fatigue and tensile tests of annealed CDA102 copper. The required performance parameters and actual test results, as well as the final joint configuration, are presented. 2 refs., 9 figs., 4 tabs.« less

  12. Comparison of field olfactometers in a controlled chamber using hydrogen sulfide as the test odorant.

    PubMed

    McGinley, M A; McGinley, C M

    2004-01-01

    A standard method for measuring and quantifying odour in the ambient air utilizes a portable odour detecting and measuring device known as a field olfactometer (US Public Health Service Project Grant A-58-541). The field olfactometer dynamically dilutes the ambient air with carbon-filtered air in distinct ratios known as "Dilutions-to-Threshold" dilution factors (D/Ts), i.e. 2, 4, 7, 15, etc. Thirteen US states and several cities in North America currently utilize field olfactometry as a key component of determining compliance to odour regulations and ordinances. A controlled environmental chamber was utilized, with hydrogen sulfide as the known test odorant. A hydrogen sulfide environment was created in this controlled chamber using an Advanced Calibration Designs, Inc. Cal2000 Hydrogen Sulfide Generator. The hydrogen sulfide concentration inside the chamber was monitored using an Arizona Instruments, Inc. Jerome Model 631 H2S Analyzer. When the environmental chamber reached a desired test concentration, test operators entered the chamber. The dilution-to-threshold odour concentration was measured using a Nasal Ranger Field Olfactometer (St Croix Sensory, Inc.) and a Barnebey Sutcliffe Corp. Scentometer. The actual hydrogen sulfide concentration was also measured at the location in the room where the operators were standing while using the two types of field olfactometers. This paper presents a correlation between dilution-to-threshold values (D/T) and hydrogen sulfide ambient concentration. For example, a D/T of 7 corresponds to ambient H2S concentrations of 5.7-15.6 microg/m3 (4-11 ppbv). During this study, no significant difference was found between results obtained using the Scentometer or the Nasal Ranger (r = 0.82). Also, no significant difference was found between results of multiple Nasal Ranger users (p = 0.309). The field olfactometers yielded hydrogen sulfide thresholds of 0.7-3.0 microg/m3 (0.5-2.0 ppbv). Laboratory olfactometry yielded comparable

  13. Herald : field operational test evaluation final report

    DOT National Transportation Integrated Search

    2000-09-01

    The Herald Field Operational Test (FOT) tested AM radio as a low-cost way to broadcast traveler information in rural areas. It tested the feasibility of broadcasting data on the inaudible portion of an existing AM broadcast. Two systems were tested, ...

  14. Herald Field Operation Test Evaluation : Final Report

    DOT National Transportation Integrated Search

    2000-09-01

    The Herald Field Operational Test (FOT) tested AM radio as a low-cost way to broadcast traveler information in rural areas. It tested the feasibility of broadcasting data on the inaudible portion of an existing AM broadcast. Two systems were tested, ...

  15. Effects of Motion in the Far Peripheral Visual Field on Cognitive Test Performance and Cognitive Load.

    PubMed

    Bevilacqua, Andy; Paas, Fred; Krigbaum, Genomary

    2016-04-01

    Cognitive load theory posits that limited attention is in actuality a limitation in working memory resources. The load theory of selective attention and cognitive control sees the interplay between attention and awareness as separate modifying functions that act on working memory. Reconciling the theoretical differences in these two theories has important implications for learning. Thirty-nine adult participants performed a cognitively demanding test, with and without movement in the far peripheral field. Although the results for movement effects on cognitive load in this experiment were not statistically significant, men spent less time on the cognitive test in the peripheral movement condition than in the conditions without peripheral movement. No such difference was found for women. The implications of these results and recommendations for future research that extends the present study are presented. © The Author(s) 2016.

  16. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhlman, Kristopher L.; Brady, Patrick V.; MacKinnon, Robert J.

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuelmore » and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).« less

  17. Redding Responder Field Test - UTC

    DOT National Transportation Integrated Search

    2008-10-30

    This UTC project facilitated field testing and evaluation of the "Responder" system between Phases 1 and 2 of the Redding Responder Project, sponsored by the California Department of Transportation. A pilot system, with hardware purchased by Caltrans...

  18. Field Testing of Cryogenic Carbon Capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sayre, Aaron; Frankman, Dave; Baxter, Andrew

    Sustainable Energy Solutions has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time two processes have been developed, the External Cooling Loop and Compressed Flue Gas Cryogenic Carbon Capture processes (CCC ECL™ and CCC CFG™ respectively). The CCC ECL™ process has been scaled up to a 1TPD CO2 system. In this process the flue gas is cooled by an external refrigerant loop. SES has tested CCC ECL™ on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cementmore » kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC CFG™ process has been scaled up to a .25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC CFG™ was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC, the results of field testing and the future steps surrounding the development of this technology.« less

  19. Direct Field Acoustic Testing

    NASA Technical Reports Server (NTRS)

    Larkin, Paul; Goldstein, Bob

    2008-01-01

    This paper presents an update to the methods and procedures used in Direct Field Acoustic Testing (DFAT). The paper will discuss some of the recent techniques and developments that are currently being used and the future publication of a reference standard. Acoustic testing using commercial sound system components is becoming a popular and cost effective way of generating a required acoustic test environment both in and out of a reverberant chamber. This paper will present the DFAT test method, the usual setup and procedure and the development and use of a closed-loop, narrow-band control system. Narrow-band control of the acoustic PSD allows all standard techniques and procedures currently used in random control to be applied to acoustics and some examples are given. The paper will conclude with a summary of the development of a standard practice guideline that is hoped to be available in the first quarter of next year.

  20. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    NASA Astrophysics Data System (ADS)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  1. DESTRUCTION OF TETRAPHENYLBORATE IN TANK 48H USING WET AIR OXIDATION BATCH BENCH SCALE AUTOCLAVE TESTING WITH ACTUAL RADIOACTIVE TANK 48H WASTE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adu-Wusu, K; Paul Burket, P

    2009-03-31

    Wet Air Oxidation (WAO) is one of the two technologies being considered for the destruction of Tetraphenylborate (TPB) in Tank 48H. Batch bench-scale autoclave testing with radioactive (actual) Tank 48H waste is among the tests required in the WAO Technology Maturation Plan. The goal of the autoclave testing is to validate that the simulant being used for extensive WAO vendor testing adequately represents the Tank 48H waste. The test objective was to demonstrate comparable test results when running simulated waste and real waste under similar test conditions. Specifically: (1) Confirm the TPB destruction efficiency and rate (same reaction times) obtainedmore » from comparable simulant tests, (2) Determine the destruction efficiency of other organics including biphenyl, (3) Identify and quantify the reaction byproducts, and (4) Determine off-gas composition. Batch bench-scale stirred autoclave tests were conducted with simulated and actual Tank 48H wastes at SRNL. Experimental conditions were chosen based on continuous-flow pilot-scale simulant testing performed at Siemens Water Technologies Corporation (SWT) in Rothschild, Wisconsin. The following items were demonstrated as a result of this testing. (1) Tetraphenylborate was destroyed to below detection limits during the 1-hour reaction time at 280 C. Destruction efficiency of TPB was > 99.997%. (2) Other organics (TPB associated compounds), except biphenyl, were destroyed to below their respective detection limits. Biphenyl was partially destroyed in the process, mainly due to its propensity to reside in the vapor phase during the WAO reaction. Biphenyl is expected to be removed in the gas phase during the actual process, which is a continuous-flow system. (3) Reaction byproducts, remnants of MST, and the PUREX sludge, were characterized in this work. Radioactive species, such as Pu, Sr-90 and Cs-137 were quantified in the filtrate and slurry samples. Notably, Cs-137, boron and potassium were shown as soluble as

  2. Photovoltaic-Powered Vaccine Refrigerator: Freezer Systems Field Test Results

    NASA Technical Reports Server (NTRS)

    Ratajczak, A. F.

    1985-01-01

    A project to develop and field test photovoltaic-powered refrigerator/freezers suitable for vaccine storage was undertaken. Three refrigerator/freezers were qualified; one by Solar Power Corp. and two by Solvolt. Follow-on contracts were awarded for 19 field test systems and for 10 field test systems. A total of 29 systems were installed in 24 countries between October 1981 and October 1984. The project, systems descriptions, installation experiences, performance data for the 22 systems for which field test data was reported, an operational reliability summary, and recommendations relative to system designs and future use of such systems are explained. Performance data indicate that the systems are highly reliable and are capable of maintaining proper vaccine storage temperatures in a wide range of climatological and user environments.

  3. Collection of quantitative chemical release field data.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.; Macha, S.; Loyola Univ.

    1999-01-01

    Detection and quantitation of chemicals in the environment requires Fourier-transform infrared (FTIR) instruments that are properly calibrated and tested. This calibration and testing requires field testing using matrices that are representative of actual instrument use conditions. Three methods commonly used for developing calibration files and training sets in the field are a closed optical cell or chamber, a large-scale chemical release, and a small-scale chemical release. There is no best method. The advantages and limitations of each method should be considered in evaluating field results. Proper calibration characterizes the sensitivity of an instrument, its ability to detect a component inmore » different matrices, and the quantitative accuracy and precision of the results.« less

  4. A comparison of blood alcohol levels as determined by breath and blood tests taken in actual field operations.

    DOT National Transportation Integrated Search

    1972-01-01

    During its 1972 session, the General Assembly of Virginia enacted Senate Bill 104, which authorizes the breath test, as well as the blood test used previously, as a proper chemical test to determine the alcoholic content of the blood. Any person arre...

  5. A prototype tap test imaging system: Initial field test results

    NASA Astrophysics Data System (ADS)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  6. Construct validity of tests that measure kick performance for young soccer players based on cluster analysis: exploring the relationship between coaches rating and actual measures.

    PubMed

    Palucci Vieira, Luiz H; de Andrade, Vitor L; Aquino, Rodrigo L; Moraes, Renato; Barbieri, Fabio A; Cunha, Sérgio A; Bedo, Bruno L; Santiago, Paulo R

    2017-12-01

    The main aim of this study was to verify the relationship between the classification of coaches and actual performance in field tests that measure the kicking performance in young soccer players, using the K-means clustering technique. Twenty-three U-14 players performed 8 tests to measure their kicking performance. Four experienced coaches provided a rating for each player as follows: 1: poor; 2: below average; 3: average; 4: very good; 5: excellent as related to three parameters (i.e. accuracy, power and ability to put spin on the ball). The scores interval established from k-means cluster metric was useful to originating five groups of performance level, since ANOVA revealed significant differences between clusters generated (P<0.01). Accuracy seems to be moderately predicted by the penalty kick, free kick, kicking the ball rolling and Wall Volley Test (0.44≤r≤0.56), while the ability to put spin on the ball can be measured by the free kick and the corner kick tests (0.52≤r≤0.61). Body measurements, age and PHV did not systematically influence the performance. The Wall Volley Test seems to be a good predictor of other tests. Five tests showed reasonable construct validity and can be used to predict the accuracy (penalty kick, free kick, kicking a rolling ball and Wall Volley Test) and ability to put spin on the ball (free kick and corner kick tests) when kicking in soccer. In contrast, the goal kick, kicking the ball when airborne and the vertical kick tests exhibited low power of discrimination and using them should be viewed with caution.

  7. Testing of Photomultiplier Tubes in a Magnetic Field

    NASA Astrophysics Data System (ADS)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  8. Who is Self-Actualized?

    ERIC Educational Resources Information Center

    Roweton, William E.

    1981-01-01

    In an attempt to clarify Maslow's concept of self-actualization as it relates to human motivation, a class of educational psychology students wrote essays describing a self-actualized person and then attempted to decide whether public schools contribute to the production of self-actualized persons. Two-thirds of the students decided that schools…

  9. Digital Audio Radio Field Tests

    NASA Technical Reports Server (NTRS)

    Hollansworth, James E.

    1997-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the beginning of phase two of Digital Audio Radio testing conducted by the Consumer Electronic Manufacturers Association (a sector of the Electronic Industries Association and the National Radio Systems Committee) and cosponsored by the Electronic Industries Association and the National Association of Broadcasters. The bulk of the field testing of the four systems should be complete by the end of October 1996, with results available soon thereafter. Lewis hosted phase one of the testing process, which included laboratory testing of seven proposed digital audio radio systems and modes (see the following table). Two of the proposed systems operate in two modes, thus making a total of nine systems for testing. These nine systems are divided into the following types of transmission: in-band on channel (IBOC), in-band adjacent channel (IBAC), and new bands - the L-band (1452 to 1492 MHz) and the S-band (2310 to 2360 MHz).

  10. Portable Imagery Quality Assessment Test Field for Uav Sensors

    NASA Astrophysics Data System (ADS)

    Dąbrowski, R.; Jenerowicz, A.

    2015-08-01

    Nowadays the imagery data acquired from UAV sensors are the main source of all data used in various remote sensing applications, photogrammetry projects and in imagery intelligence (IMINT) as well as in other tasks as decision support. Therefore quality assessment of such imagery is an important task. The research team from Military University of Technology, Faculty of Civil Engineering and Geodesy, Geodesy Institute, Department of Remote Sensing and Photogrammetry has designed and prepared special test field- The Portable Imagery Quality Assessment Test Field (PIQuAT) that provides quality assessment in field conditions of images obtained with sensors mounted on UAVs. The PIQuAT consists of 6 individual segments, when combined allow for determine radiometric, spectral and spatial resolution of images acquired from UAVs. All segments of the PIQuAT can be used together in various configurations or independently. All elements of The Portable Imagery Quality Assessment Test Field were tested in laboratory conditions in terms of their radiometry and spectral reflectance characteristics.

  11. Collaborative Research: Bringing Problem Solving in the Field into the Classroom: Developing and Assessing Virtual Field Trips for Teaching Sedimentary and Introductory Geology

    NASA Astrophysics Data System (ADS)

    Wang, P.; Caldwell, M.

    2012-12-01

    Coastal Florida offers a unique setting for the facilitation of learning about a variety of modern sedimentary environments. Despite the conflicting concept of "virtual" and "actual" field trip, and the uncertainties associated with the implementation and effectiveness, virtual trips provide likely the only way to reach a large diversified student population and eliminate travel time and expenses. In addition, with rapidly improving web and visualization technology, field trips can be simulated virtually. It is therefore essential to systematically develop and assess the educational effectiveness of virtual field trips. This project is developing, implementing, and assessing a series of virtual field trips for teaching undergraduate sedimentary geology at a large four-year research university and introductory geology at a large two-year community college. The virtual field trip is based on a four-day actual field trip for a senior level sedimentary geology class. Two versions of the virtual field trip, one for advanced class and one for introductory class, are being produced. The educational outcome of the virtual field trip will be compared to that from actual field trip. This presentation summarizes Year 1 achievements of the three-year project. The filming, editing, and initial production of the virtual field trip have been completed. Formative assessments were conducted by the Coalition for Science Literacy at the University of South Florida. Once tested and refined, the virtual field trips will be disseminated through broadly used web portals and workshops at regional and national meetings.

  12. Quantitative muscle strength testing: a comparison of job strength requirements and actual worker strength among military technicians.

    PubMed

    Pedersen, D M; Clark, J A; Johns, R E; White, G L; Hoffman, S

    1989-01-01

    In this study the authors investigate the percentage of mismatch between job demands and worker physical capacity in Utah National Guard mechanics. This population had demonstrated a higher incidence of low back trouble than other job descriptions reviewed. The authors utilized onsite still and videotape photography and a computerized biomechanical strength prediction model to assess loads on the lumbosacral spine due to various job tasks. Job demands were then compared to the actual physical capacity of the individual workers based on static strength testing in job-related positions. A load cell on the testing apparatus entered the force generated into a computer which averaged the force of the last three seconds of a five-second lift. It was determined that as much as a 38% mismatch existed within this population for some job tasks which these workers were exposed to. Suggestions for preventing job-related low back cumulative trauma disorders are presented, including: engineering redesign, worker selection programs, work hardening, and others.

  13. [New visual field testing possibilities (a preliminary report)].

    PubMed

    Erichev, V P; Ermolaev, A P; Antonov, A A; Grigoryan, G L; Kosova, D V

    2018-01-01

    There are currently no portable mobile perimeters that allow visual field testing outside ophthalmologist's examination rooms. To develop a mobile perimetry technique based on use of a virtual reality headset (VR). The study involved 26 patients (30 eyes) with II-III stage primary open-angle glaucoma (POAG) with compensated IOP. Perimetry was performed for each patient twice - on Humphrey analyzer (test 30-2, 76 points) and employing similar strategy on a perimeter integrated into VR headset (Total Vision, Russia). Visual field testing was performed with an interval from 1 hour to 3 days. The results were comparatively analyzed. Patients tolerated the examination well. Comparative analysis of preliminary perimetry results obtained with both methods showed high degree of identity, so the results were concluded to be comparable. By visually isolating the wearer, VR headset achieves elimination of distractions and stable light conditions for visual field testing. The headset-perimeter is compact, mobile, easily transportable, can be used in the work of visiting medical teams and for examination at home.

  14. Field-testing UV disinfection of drinking water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gadgil, A.; Drescher, A.; Greene, D.

    A recently invented device, ``UV Waterworks,`` uses ultraviolet (UV) light to disinfect drinking water. Its novel features are: low cost, robust design, rapid disinfection, low electricity use, low maintenance, high flow rate and ability to work with unpressurized water sources. The device could service a community of 1,000 persons, at an annual total cost of less than 10 US cents per person. UV Waterworks has been successfully tested in the laboratory. Limited field trials of an early version of the device were conducted in India in 1994--95. Insights from these trials led to the present design. Extended field trials ofmore » UV Waterworks, initiated in South Africa in February 1997, will be coordinated by the South African Center for Essential Community Services (SACECS), with technical and organizational support from Lawrence Berkeley National Laboratory(LBNL) and the Natural Resources Defense Council (both US). The first of the eight planned sites of the year long trial is an AIDS hospice near Durban. Durban metro Water and LBNL lab-tested a UV Waterworks unit prior to installing it at the hospice in August, 1997. The authors describe the field test plans and preliminary results from Durban.« less

  15. Validity of Selected Lab and Field Tests of Physical Working Capacity.

    ERIC Educational Resources Information Center

    Burke, Edmund J.

    The validity of selected lab and field tests of physical working capacity was investigated. Forty-four male college students were administered a series of lab and field tests of physical working capacity. Lab tests include a test of maximum oxygen uptake, the PWC 170 test, the Harvard Step Test, the Progressive Pulse Ratio Test, Margaria Test of…

  16. Superconductor shields test chamber from ambient magnetic fields

    NASA Technical Reports Server (NTRS)

    Hildebrandt, A. F.

    1965-01-01

    Shielding a test chamber for magnetic components enables it to maintain a constant, low magnetic field. The chamber is shielded from ambient magnetic fields by a lead foil cylinder maintained in a superconducting state by liquid helium.

  17. Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?

    PubMed Central

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = −0.81) and barbell shoulder press (rs = −0.77), for Pulling: IE shoulder extension (rs = −0.82) and bench press (rs = −0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = −0.83) and bench press (rs = −0.82), and for the Terrain work task: IE trunk flexion (rs = −0.58) and upright barbell row (rs = −0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity. PMID:24614596

  18. Laboratory or field tests for evaluating firefighters' work capacity?

    PubMed

    Lindberg, Ann-Sofie; Oksa, Juha; Malm, Christer

    2014-01-01

    Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) and part-time (N = 10) male firefighters and civilian men (N = 8) and women (N = 12), and also to give recommendations as to which field tests might be useful for evaluating firefighters' physical work capacity. Laboratory tests of isokinetic maximal (IM) and endurance (IE) muscle power and dynamic balance, field tests including maximal and endurance muscle performance, and simulated firefighting work tasks were performed. Correlations with work capacity were analyzed with Spearman's rank correlation coefficient (rs). The highest significant (p<0.01) correlations with laboratory and field tests were for Cutting: IE trunk extension (rs = 0.72) and maximal hand grip strength (rs = 0.67), for Stairs: IE shoulder flexion (rs = -0.81) and barbell shoulder press (rs = -0.77), for Pulling: IE shoulder extension (rs = -0.82) and bench press (rs = -0.85), for Demolition: IE knee extension (rs = 0.75) and bench press (rs = 0.83), for Rescue: IE shoulder flexion (rs = -0.83) and bench press (rs = -0.82), and for the Terrain work task: IE trunk flexion (rs = -0.58) and upright barbell row (rs = -0.70). In conclusion, field tests may be used instead of laboratory tests. Maximal hand grip strength, bench press, chin ups, dips, upright barbell row, standing broad jump, and barbell shoulder press were strongly correlated (rs≥0.7) with work capacity and are therefore recommended for evaluating firefighters work capacity.

  19. RESOLVE 2010 Field Test

    NASA Technical Reports Server (NTRS)

    Captain, J.; Quinn, J.; Moss, T.; Weis, K.

    2010-01-01

    This slide presentation reviews the field tests conducted in 2010 of the Regolith Environment Science & Oxygen & Lunar Volatile Extraction (RESOLVE). The Resolve program consist of several mechanism: (1) Excavation and Bulk Regolith Characterization (EBRC) which is designed to act as a drill and crusher, (2) Regolith Volatiles Characterization (RVC) which is a reactor and does gas analysis,(3) Lunar Water Resources Demonstration (LWRD) which is a fluid system, water and hydrogen capture device and (4) the Rover. The scientific goal of this test is to demonstrate evolution of low levels of hydrogen and water as a function of temperature. The Engineering goals of this test are to demonstrate:(1) Integration onto new rover (2) Miniaturization of electronics rack (3) Operation from battery packs (elimination of generator) (4) Remote command/control and (5) Operation while roving. Views of the 2008 and the 2010 mechanisms, a overhead view of the mission path, a view of the terrain, the two drill sites, and a graphic of the Master Events Controller Graphical User Interface (MEC GUI) are shown. There are descriptions of the Gas chromatography (GC), the operational procedure, water and hydrogen doping of tephra. There is also a review of some of the results, and future direction for research and tests.

  20. Mission control team structure and operational lessons learned from the 2009 and 2010 NASA desert RATS simulated lunar exploration field tests

    NASA Astrophysics Data System (ADS)

    Bell, Ernest R.; Badillo, Victor; Coan, David; Johnson, Kieth; Ney, Zane; Rosenbaum, Megan; Smart, Tifanie; Stone, Jeffry; Stueber, Ronald; Welsh, Daren; Guirgis, Peggy; Looper, Chris; McDaniel, Randall

    2013-10-01

    team the opportunity to gain insight into functional hardware requirements via lessons learned from executing the Desert RATS field test missions. This paper will detail the mission control team structure that was used during the 2009 and 2010 Desert RATS Lunar analog missions. It will also present a number of the lessons learned by the operations team during these field tests. Major lessons learned involved Mission Control Center (MCC) operations, pre-mission planning and training processes, procedure requirements, communication requirements, and logistic support for analogs. This knowledge will be applied to future Desert RATS field tests, and other Earth based analog testing for space exploration, to continue the evolution of manned space operations in preparation for human planetary exploration. It is important that operational knowledge for human space exploration missions be obtained during Earth-bound field tests to the greatest extent possible. This allows operations personnel the ability to examine various flight control and crew operations scenarios in preparation for actual space missions.

  1. [Status and actualization of tasks to improve the scientific-methodological and regulatory frameworks in the field of human ecology and environmental health].

    PubMed

    Rakhmanin, Iu A; Sinitsyna, O O

    2013-01-01

    Contemporary factors that affect the health of the population have been analyzed. There was shown the growing activity of chemical pollution of the environment. Therefore, in order to prevent the growth of negative health and environment consequences caused by increased levels of exposure to chemicals preventive potential for solutions of this complex problem and all strenuous efforts to assist possibly of the sound management of the chemicals should be enhanced. Problematic issues of harmonization of the Russian normative and guidance documents have been actualized. Perspective directions of science development in the field of human ecology and environmental health are suggested.

  2. Field-based video pre-test counseling, oral testing, and telephonic post-test counseling: implementation of an HIV field testing package among high-risk Indian men.

    PubMed

    Snyder, Hannah; Yeldandi, Vijay V; Prem Kumar, G; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A

    2012-08-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. A total of 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one-third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care.

  3. Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martino, C.; Newell, D.; Woodham, W.

    To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solutionmore » excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing.« less

  4. The accuracy of confrontation visual field test in comparison with automated perimetry.

    PubMed Central

    Johnson, L. N.; Baloh, F. G.

    1991-01-01

    The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764

  5. Comparative Field Tests of Pressurised Rover Prototypes

    NASA Astrophysics Data System (ADS)

    Mann, G. A.; Wood, N. B.; Clarke, J. D.; Piechochinski, S.; Bamsey, M.; Laing, J. H.

    The conceptual designs, interior layouts and operational performances of three pressurised rover prototypes - Aonia, ARES and Everest - were field tested during a recent simulation at the Mars Desert Research Station in Utah. A human factors experiment, in which the same crew of three executed the same simulated science mission in each of the three vehicles, yielded comparative data on the capacity of each vehicle to safely and comfortably carry explorers away from the main base, enter and exit the vehicle in spacesuits, perform science tasks in the field, and manage geological and biological samples. As well as offering recommendations for design improvements for specific vehicles, the results suggest that a conventional Sports Utility Vehicle (SUV) would not be suitable for analog field work; that a pressurised docking tunnel to the main habitat is essential; that better provisions for spacesuit storage are required; and that a crew consisting of one driver/navigator and two field science crew specialists may be optimal. From a field operations viewpoint, a recurring conflict between rover and habitat crews at the time of return to the habitat was observed. An analysis of these incidents leads to proposed refinements of operational protocols, specific crew training for rover returns and again points to the need for a pressurised docking tunnel. Sound field testing, circulating of results, and building the lessons learned into new vehicles is advocated as a way of producing ever higher fidelity rover analogues.

  6. Vadose Zone Transport Field Study: Detailed Test Plan for Simulated Leak Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Anderson L.; Gee, Glendon W.

    2000-06-23

    This report describes controlled transport experiments at well-instrumented field tests to be conducted during FY 2000 in support of DOE?s Vadose Zone Transport Field Study (VZTFS). The VZTFS supports the Groundwater/Vadose Zone Integration Project Science and Technology Initiative. The field tests will improve understanding of field-scale transport and lead to the development or identification of efficient and cost-effective characterization methods. These methods will capture the extent of contaminant plumes using existing steel-cased boreholes. Specific objectives are to 1) identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford?s waste disposal sites; 2) reduce uncertainty in conceptualmore » models; 3) develop a detailed and accurate data base of hydraulic and transport parameters for validation of three-dimensional numerical models; and 4) identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. Pacific Northwest National Laboratory (PNNL) manages the VZTFS for DOE.« less

  7. Baseline performance of solar collectors for NASA Langley solar building test facility

    NASA Technical Reports Server (NTRS)

    Knoll, R. H.; Johnson, S. M.

    1977-01-01

    The solar collector field contains seven collector designs. Before operation in the field, the experimental performances (thermal efficiencies) of the seven collector designs were measured in an indoor solar simulator. The resulting data provided a baseline for later comparison with actual field test data. The simulator test results are presented for the collectors as received, and after several weeks of outdoor exposure with no coolant (dry operation). Six of the seven collector designs tested showed substantial reductions in thermal efficiency after dry operation.

  8. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a

  9. I-55 OGFC field permeability testing.

    DOT National Transportation Integrated Search

    2009-12-01

    An OGFC test section was constructed on I-55 in Copiah County, MS during the : spring/summer of 2007. As part of the study, literature was reviewed and a falling head : permeability device was identified that has been used in laboratory and field stu...

  10. Field testing of aquifer thermal energy storage

    NASA Astrophysics Data System (ADS)

    Kannberg, L. D.; Allen, R. D.

    1984-03-01

    Results of field and laboratory studies of aquifer thermal energy storage (ATES) indicate both the problems and promise of the concept. Geohydrothermal modeling and field testing demonstrated the ability to recover substantial quantities of aquifer stored energy. However, the local hydrologic conditions play an important role in determining the recovery temperature and storage efficiency. Geochemistry is also an important factor, particularly for higher temperature ATES systems.

  11. Testing the Effect of Cropping Practices on Soil Erosion Rates - Application of Field Rainfall Simulator

    NASA Astrophysics Data System (ADS)

    Dostál, Tomáš; Zumr, David; Krása, Josef; Kavka, Petr; Strouhal, Luděk

    2017-04-01

    C factor, the protection effect of the vegetation cover, is a key parameter which is introduced in the basic empirical soil erosion relationships (e.g. USLE). The C factor values for various crops in various grow stages are usually estimated based on the catalogue values. As these values often do not fit to the observed data from the plot experiments or do not represent actually grown crops, we decided to validate and extend the database. We present a methodology and primary results of tens of the field rainfall simulation experiments conducted on several agricultural crops with different BBCH. The rainfall simulations were done with the mobile field rainfall simulator of the Czech Technical University. The tested plots of the size 2 x 8,7 m were repeatedly exposed to the artificial rainfalls with intensity of 60 mm/h and duration of 30 to 60 minutes. The experiments were always performed twice on a bare soil and twice on the vegetated plots (to mimic dry and wet initial soil conditions). The tests were done on several slopes in the Czech Republic, the soils were mostly Cambisols with various organic matter content and stoniness. Based on the results we will be able to correct and validate the C factor values for the currently most widely grown crops in the conditions of the Central Europe. The presentation is funded by Ministry of Agriculture of the Czech Republic (research project QJ1530181) and an internal student CTU grant.

  12. Field-based video pre-test counseling, oral testing and telephonic post-test counseling: Implementation of an HIV field testing package among high-risk Indian men

    PubMed Central

    Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.

    2013-01-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. Those who had previously been tested preferred traditional methods to video counseling. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care. PMID:22827901

  13. Dancers' Perceived and Actual Knowledge of Anatomy.

    PubMed

    Kotler, Dana H; Lynch, Meaghan; Cushman, Daniel; Hu, Jason; Garner, Jocelyn

    2017-06-15

    Dancers are highly susceptible to musculoskeletal injuries and frequently require interaction with medical professionals. While many dancers have a finely tuned awareness of their bodies, their knowledge of the fundamentals of human anatomy is not uniform. There is a paucity of literature on the benefits of human anatomy education in dancers, though it seems intuitive that there should be a relationship. The purpose of this study was to assess dancers' perceived and actual knowledge of basic musculoskeletal anatomy and its relationship to function. Adult dancers at the undergraduate, pre-professional, and professional levels were surveyed through an anonymous online questionnaire. Questions included demographic information, dance techniques studied, anatomy training, and injury history. Subjects rated their perceived knowledge of anatomy and were tested with 15 multiple-choice questions on basic musculoskeletal anatomy. Four hundred seventy-five surveys were completed. Ordinal regression showed a correlation of perceived to actual knowledge of anatomy (p < 0.001). Factors that correlated with increases in both perceived and actual knowledge of anatomy included having taken an anatomy course of any type (p < 0.001) and increased age (p ≤ 0.001). Years of dance training and professional dancer status both significantly correlated with increased knowledge of anatomy (p < 0.001) but not perceived knowledge. Chi-square analysis showed that dancers with training in either modern or jazz dance had a significantly higher perceived, but not actual, knowledge when compared to those without training in those styles of dance (p < 0.001 and p = 0.011, respectively). In conclusion, dancers generally scored well on questions pertaining to basic musculoskeletal anatomy, and their perception correlated with their actual knowledge of anatomy. Factors that contribute to dancers' knowledge of anatomy include age, years of experience, professional dancer status, and anatomy training.

  14. Antarctic field tests of SARSAT personal locater beacons

    NASA Technical Reports Server (NTRS)

    Bindschadler, Robert

    1987-01-01

    Field tests of SARSAT personal locater beacons were conducted in the Antarctic to assess the viability of using these beacons to increase the safety of Antarctic field parties. Data were collected on the extent to which dry or wet snow, melting conditions, crevasse walls and snow bridges affected the ability of the SARSAT satellite to calculate an accurate position of the beacon. Average response time between beacon turn on and alert reception in McMurdo was between 4 and 5 hours for these tests. It is concluded that the SARSAT system is viable for Antarctic operations and it is recommended that it be implemented for future field operations. Because of obstruction of line-of-sight between beacon and satellite degrades the accuracy of the location calculation (particularly in wet snow), it is further recommended that field parties have sufficient numbers of beacons to insure that in an emergency, one will be able to operate from the surface.

  15. Deep Borehole Field Test Conceptual Design Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, Ernest L.

    This report documents conceptual design development for the Deep Borehole Field Test (DBFT), including test packages (simulated waste packages, not containing waste) and a system for demonstrating emplacement and retrieval of those packages in the planned Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system. This document therefore identifies key options for a DBD system, describes an updated reference DBD concept, and derives a recommended concept for the DBFT demonstration. The objective of the DBFT is to confirm the safety and feasibility of the DBDmore » concept for long-term isolation of radioactive waste. The conceptual design described in this report will demonstrate equipment and operations for safe waste handling and downhole emplacement of test packages, while contributing to an evaluation of the overall safety and practicality of the DBD concept. The DBFT also includes drilling and downhole characterization investigations that are described elsewhere (see Section 1). Importantly, no radioactive waste will be used in the DBFT, nor will the DBFT site be used for disposal of any type of waste. The foremost performance objective for conduct of the DBFT is to demonstrate safe operations in all aspects of the test.« less

  16. Idaho out-of-service verification field operational test

    DOT National Transportation Integrated Search

    2000-02-01

    The Out-of-Service Verification Field Operational Test Project was initiated in 1994. The purpose of the project was to test the feasibility of using sensors and a computerized tracking system to augment the ability of inspectors to monitor and contr...

  17. Effect of a patient training video on visual field test reliability

    PubMed Central

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-01-01

    Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740

  18. Effect of a patient training video on visual field test reliability.

    PubMed

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-02-01

    To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarize them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye.

  19. 40 CFR 35.2262 - Funding of field testing.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Funding of field testing. 35.2262 Section 35.2262 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2262 Funding of field...

  20. 40 CFR 35.2262 - Funding of field testing.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Funding of field testing. 35.2262 Section 35.2262 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2262 Funding of field...

  1. 40 CFR 35.2262 - Funding of field testing.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Funding of field testing. 35.2262 Section 35.2262 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2262 Funding of field...

  2. Field testing of a lightweight relocatable structure in a desert environment

    NASA Astrophysics Data System (ADS)

    Kao, A.; Lane, S.; Carr, J. S.; Wahlgren, L.; Klause, P.

    1984-09-01

    This report describes the field tests of a commercially available, off-the-shelf lightweight relocatable structure (LRS) systems selected for possible military application in a theater or operations. The structural system selected for the field tests was a panelized system manufactured by Kelly Klosure, Inc. The purpose of the tests was to determine the constructibility and habitability of the building system. The tests are being conducted in two stages: Stage 1 tests were conducted in a desert environment, and Stage 2 tests are being conducted in a temperate environment. This report documents the results of the Stage 1 tests. The test results showed that the 20-ft-wide and 8-ft-high building can be erected manually by unskilled troop labor using only hand tools. However, for a 12-ft-high building assembled using 4- x 8-ft panels, a crane is needed to help lift assembled components for the erection. Based on overall constructibility and environmental performance, the fiberboard panel system is the better choice. Several modifications were made to the system during the field tests. It is recommended that these modifications be incorporated into system design and further field tests conducted before making a final evaluation.

  3. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Actual Waste Testing with SRS Tank 5F Sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, William D.; Hay, Michael S.

    Solubility testing with actual High Level Waste tank sludge has been conducted in order to evaluate several alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge sluicing efforts. Tests were conducted with archived Savannah River Site (SRS) radioactive sludge solids that had been retrieved from Tank 5F in order to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent toward dissolving the bulk non-radioactive waste components. Solubility tests were performed by direct sludge contact with the oxalic/nitric acid reagent and with sludge that had beenmore » pretreated and acidified with dilute nitric acid. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid following current baseline tank chemical cleaning methods. One goal of testing with the optimized reagent was to compare the total amounts of oxalic acid and water required for sludge dissolution using the baseline and optimized cleaning methods. A second objective was to compare the two methods with regard to the dissolution of actinide species known to be drivers for SRS tank closure Performance Assessments (PA). Additionally, solubility tests were conducted with Tank 5 sludge using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species.« less

  4. Field Performance versus Standard Test Condition Efficiency of Tandem Solar Cells and the Singular Case of Perovskites/Silicon Devices.

    PubMed

    Dupré, Olivier; Niesen, Bjoern; De Wolf, Stefaan; Ballif, Christophe

    2018-01-18

    Multijunction cells may offer a cost-effective route to boost the efficiency of industrial photovoltaics. For any technology to be deployed in the field, its performance under actual operating conditions is extremely important. In this perspective, we evaluate the impact of spectrum, light intensity, and module temperature variations on the efficiency of tandem devices with crystalline silicon bottom cells with a particular focus on perovskite top cells. We consider devices with different efficiencies and calculate their energy yields using field data from Denver. We find that annual losses due to differences between operating conditions and standard test conditions are similar for single-junction and four-terminal tandem devices. The additional loss for the two-terminal tandem configuration caused by current mismatch reduces its performance ratio by only 1.7% when an optimal top cell bandgap is used. Additionally, the unusual bandgap temperature dependence of perovskites is shown to have a positive, compensating effect on current mismatch.

  5. Does the Cognitive Reflection Test actually capture heuristic versus analytic reasoning styles in older adults?

    PubMed

    Hertzog, Christopher; Smith, R Marit; Ariel, Robert

    2018-01-01

    Background/Study Context: This study evaluated adult age differences in the original three-item Cognitive Reflection Test (CRT; Frederick, 2005, The Journal of Economic Perspectives, 19, 25-42) and an expanded seven-item version of that test (Toplak et al., 2013, Thinking and Reasoning, 20, 147-168). The CRT is a numerical problem-solving test thought to capture a disposition towards either rapid, intuition-based problem solving (Type I reasoning) or a more thoughtful, analytical problem-solving approach (Type II reasoning). Test items are designed to induce heuristically guided errors that can be avoided if using an appropriate numerical representation of the test problems. We evaluated differences between young adults and old adults in CRT performance and correlates of CRT performance. Older adults (ages 60 to 80) were paid volunteers who participated in experiments assessing age differences in self-regulated learning. Young adults (ages 17 to 35) were students participating for pay as part of a project assessing measures of critical thinking skills or as a young comparison group in the self-regulated learning study. There were age differences in the number of CRT correct responses in two independent samples. Results with the original three-item CRT found older adults to have a greater relative proportion of errors based on providing the intuitive lure. However, younger adults actually had a greater proportion of intuitive errors on the long version of the CRT, relative to older adults. Item analysis indicated a much lower internal consistency of CRT items for older adults. These outcomes do not offer full support for the argument that older adults are higher in the use of a "Type I" cognitive style. The evidence was also consistent with an alternative hypothesis that age differences were due to lower levels of numeracy in the older samples. Alternative process-oriented evaluations of how older adults solve CRT items will probably be needed to determine

  6. Digital servo control of random sound fields

    NASA Technical Reports Server (NTRS)

    Nakich, R. B.

    1973-01-01

    It is necessary to place number of sensors at different positions in sound field to determine actual sound intensities to which test object is subjected. It is possible to determine whether specification is being met adequately or exceeded. Since excitation is of random nature, signals are essentially coherent and it is impossible to obtain true average.

  7. Field trip to Nevada test site

    USGS Publications Warehouse

    ,

    1976-01-01

    Two road logs guide the reader through the geologic scene from Las Vegas to Mercury and from Mercury through eight stops on the Nevada Test Site. Maps and cross sections depict the geology and hydrology of the area. Included among the tables is one showing the stratigraphic units in the southwestern Nevada volcanic field and another that lists the geologic maps covering the Nevada Test Site and vicinity. The relation of the geologic environment to nuclear-explosion effects is alluded to in brief discussions of collapse, surface subsidence, and cratering resulting from underground nuclear explosions.

  8. Preliminary Study on the Radar Vegetation Index (RVI) Application to Actual Paddy Fields by ALOS/PALSAR Full-polarimetry SAR Data

    NASA Astrophysics Data System (ADS)

    Yamada, Y.

    2015-04-01

    Kim and van Zyl (2001) proposed a kind of radar vegetation index (RVI). RVI = 4*min(λ1, λ2, λ3) / (λ1 + λ2 + λ3) They modified the equation as follows. (2009) RVI = 8 * σ0hv / (σ0hh + σ0vv +σ0hv ) by L-band full-polarimetric SAR data. They applied it into rice crop and soybean. (Y.Kim, T.Jackson et al., 2012) They compared RVI for L-, C- and X-bands to crop growth data, LAI and NDVI. They found L-band RVI was well correlated with Vegetation Water Content, LAI and NDVI. But the field data were collected by the multifrequency polarimetric scatterometer. The platform height was 4.16 meters from the ground. The author tried to apply the method to actual paddy fields near Tsukuba science city in Japan using ALOS/PALSAR, full-polarimetry L-band SAR data. The staple crop in Eastern Asia is rice and paddy fields are dominant land use. A rice-planting machine comes into wide use in this areas. The young rice plants were bedded regularly ridged line in the paddy fields by the machine. The space between two ridges of rice plants is about 30 cm and the wave length of PALSAR sensor is about 23 cm. Hence the Bragg scattering will appear depending upon the direction of the ridges of paddy fields. Once the Bragg scattering occurs, the backscattering values from the pixels should be very high comparing the surrounding region. Therefore the radar vegetation index (RVI) would be saturated. The RVI did not follow the increasing of vegetation anymore. Japan has launched ALOS-2 satellite and it has PALSAR-2, L-band SAR. Therefore RVI application product by PALSAR-2 will be watched with deep interest.

  9. Field-test of a date-rape drug detection device.

    PubMed

    Quest, Dale W; Horsley, Joanne

    2007-01-01

    Drink Safe Technology Version 1.2 is an inexpensive color-change reagent test marketed internationally for use by consumers in settings such as a night club to detect potentially incapacitating concentrations of gamma-hydroxybutyric acid (GHB) and ketamine in beverages. The objective of this study was to compare product performance in the laboratory and performance in the hands of consumers in the field. Product performance in the laboratory adhered to the protocol defined by the manufacturer. Product performance in the hands of consumers in field settings allowed browsing participants to pipette an aliquot of their own drinks into randomly coded vials containing authentic drugs, or pure water, so as to yield the same concentrations of GHB or ketamine specified in the manufacturer-defined protocol, or blanks. Consumers were to proceed according to the directions printed on the product, and to record their results on a card with a code corresponding with the vial to which they had added an aliquot of their beverage. Diagnostic performance was calculated using two-way analysis. In the laboratory, Drink Safe Technology Version 1.2 reliably detected GHB and ketamine at concentrations specified by the manufacturer's protocol. The reactive color change denoting a positive test for GHB was rapid, but a positive test for ketamine required substantially more time to resolve. Nonetheless, test accuracy following the manufacturer's protocol in the laboratory was 100%. In the field, based on 101 paired-test results recorded by consumers, the test efficiency was 65.1%, sensitivity 50%, and specificity 91.6%. The product performed much better in the laboratory than it did in the hand of consumers in the field. There seems to be considerable potential for consumers to misinterpret a test result. The potential for consumers to record a false-negative test result for a spiked drink is cause for concern.

  10. How Are Mate Preferences Linked with Actual Mate Selection? Tests of Mate Preference Integration Algorithms Using Computer Simulations and Actual Mating Couples

    PubMed Central

    Conroy-Beam, Daniel; Buss, David M.

    2016-01-01

    Prior mate preference research has focused on the content of mate preferences. Yet in real life, people must select mates among potentials who vary along myriad dimensions. How do people incorporate information on many different mate preferences in order to choose which partner to pursue? Here, in Study 1, we compare seven candidate algorithms for integrating multiple mate preferences in a competitive agent-based model of human mate choice evolution. This model shows that a Euclidean algorithm is the most evolvable solution to the problem of selecting fitness-beneficial mates. Next, across three studies of actual couples (Study 2: n = 214; Study 3: n = 259; Study 4: n = 294) we apply the Euclidean algorithm toward predicting mate preference fulfillment overall and preference fulfillment as a function of mate value. Consistent with the hypothesis that mate preferences are integrated according to a Euclidean algorithm, we find that actual mates lie close in multidimensional preference space to the preferences of their partners. Moreover, this Euclidean preference fulfillment is greater for people who are higher in mate value, highlighting theoretically-predictable individual differences in who gets what they want. These new Euclidean tools have important implications for understanding real-world dynamics of mate selection. PMID:27276030

  11. How Are Mate Preferences Linked with Actual Mate Selection? Tests of Mate Preference Integration Algorithms Using Computer Simulations and Actual Mating Couples.

    PubMed

    Conroy-Beam, Daniel; Buss, David M

    2016-01-01

    Prior mate preference research has focused on the content of mate preferences. Yet in real life, people must select mates among potentials who vary along myriad dimensions. How do people incorporate information on many different mate preferences in order to choose which partner to pursue? Here, in Study 1, we compare seven candidate algorithms for integrating multiple mate preferences in a competitive agent-based model of human mate choice evolution. This model shows that a Euclidean algorithm is the most evolvable solution to the problem of selecting fitness-beneficial mates. Next, across three studies of actual couples (Study 2: n = 214; Study 3: n = 259; Study 4: n = 294) we apply the Euclidean algorithm toward predicting mate preference fulfillment overall and preference fulfillment as a function of mate value. Consistent with the hypothesis that mate preferences are integrated according to a Euclidean algorithm, we find that actual mates lie close in multidimensional preference space to the preferences of their partners. Moreover, this Euclidean preference fulfillment is greater for people who are higher in mate value, highlighting theoretically-predictable individual differences in who gets what they want. These new Euclidean tools have important implications for understanding real-world dynamics of mate selection.

  12. The new car assessment program: does it predict the relative safety of vehicles in actual crashes?

    PubMed

    Nirula, Ram; Mock, Charles N; Nathens, Avery B; Grossman, David C

    2004-10-01

    Federal motor vehicle safety standards are based on crash test dummy analyses that estimate the relative risk of traumatic brain injury (TBI) and severe thoracic injury (STI) by quantifying head (Head Injury Criterion [HIC]) and chest (Chest Gravity Score [CGS]) acceleration. The New Car Assessment Program (NCAP) combines these probabilities to yield the vehicle's five-star rating. The validity of the NCAP system as it relates to an actual motor vehicle crash (MVC) remains undetermined. We therefore sought to determine whether HIC and CGS accurately predict TBI and STI in actual crashes, and compared the NCAP five-star rating system to the rates of TBI and/or STI in actual MVCs. We analyzed frontal crashes with restrained drivers from the 1994 to 1998 National Automotive Sampling System. The relationship of HIC and CGS to the probabilities of TBI and STI derived from crash tests were respectively compared with the HIC-TBI and CGS-STI risk relationships observed in actual crashes while controlling for covariates. Receiver operating characteristic curves determined the sensitivity and specificity of HIC and CGS as predictors of TBI and STI, respectively. Estimates of the likelihood of TBI and/or STI (in actual MVCs) were compared with the expected probabilities of TBI and STI (determined by crash test analysis), as they relate to NCAP ratings. The crash tests overestimate TBI likelihood at HIC scores >800 and underestimate it at scores <500. STI likelihood is overestimated when CGS exceeds 40 g. Receiver operating characteristic curves demonstrated poor sensitivity and specificity of HIC and CGS in predicting injury. The actual MVC injury probability estimates did not vary between vehicles of different NCAP rating. HIC and CGS are poor predictors of TBI and STI in actual MVCs. The NCAP five-star rating system is unable to differentiate vehicles of varying crashworthiness in actual MVCs. More sensitive parameters need to be developed and incorporated into vehicle

  13. Comparison of Actual Surgical Outcomes and 3D Surgical Simulations

    PubMed Central

    Tucker, Scott; Cevidanes, Lucia; Styner, Martin; Kim, Hyungmin; Reyes, Mauricio; Proffit, William; Turvey, Timothy

    2009-01-01

    Purpose The advent of imaging software programs have proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3D surgical simulation still needs to be tested. This study was conducted to determine if the virtual surgery performed on 3D models constructed from Cone-beam CT (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. Methods Construction of pre- and post-surgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had one-piece maxillary advancement surgery was performed. The post-surgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling T-test were used to assess the differences between simulated and actual surgical outcomes. Results For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing two- and one-jaw surgeries. Conclusions Virtual surgical methods were reliably reproduced, oral surgery residents could benefit from virtual surgical training, and computer simulation has the potential to increase predictability in the operating room. PMID:20591553

  14. Development of a Pediatric Visual Field Test

    PubMed Central

    Miranda, Marco A.; Henson, David B.; Fenerty, Cecilia; Biswas, Susmito; Aslam, Tariq

    2016-01-01

    Purpose We describe a pediatric visual field (VF) test based on a computer game where software and hardware combine to provide an enjoyable test experience. Methods The test software consists of a platform-based computer game presented to the central VF. A storyline was created around the game as was a structure surrounding the computer monitor to enhance patients' experience. The patient is asked to help the central character collect magic coins (stimuli). To collect these coins a series of obstacles need to be overcome. The test was presented on a Sony PVM-2541A monitor calibrated from a central midpoint with a Minolta CS-100 photometer placed at 50 cm. Measurements were performed at 15 locations on the screen and the contrast calculated. Retinal sensitivity was determined by modulating stimulus in size. To test the feasibility of the novel approach 20 patients (4–16 years old) with no history of VF defects were recruited. Results For the 14 subjects completing the study, 31 ± 15 data points were collected on 1 eye of each patient. Mean background luminance and stimulus contrast were 9.9 ± 0.3 cd/m2 and 27.9 ± 0.1 dB, respectively. Sensitivity values obtained were similar to an adult population but variability was considerably higher – 8.3 ± 9.0 dB. Conclusions Preliminary data show the feasibility of a game-based VF test for pediatric use. Although the test was well accepted by the target population, test variability remained very high. Translational Relevance Traditional VF tests are not well tolerated by children. This study describes a child-friendly approach to test visual fields in the targeted population. PMID:27980876

  15. Self-perceived health versus actual cardiovascular disease risks.

    PubMed

    Ko, Young; Boo, Sunjoo

    2016-01-01

    Self-perceived poor health is related to cardiovascular disease (CVD) risk perception, cardiovascular event, hospital readmission, and death from CVD. This study evaluated the associations between self-perceived health and actual CVD risk in South Koreans as well as the influence of sociodemographic and cardiovascular risk factors on self-perceived poor health. This is a secondary data analysis of the 2010 Korea National Health and Nutrition Examination Survey. The sample was 4535 South Koreans aged 30-74 years without CVD. Self-perceived health status was compared with actual cardiovascular risk separately by sex using χ(2) -tests. Logistic regressions were used to identify potential sociodemographic and cardiovascular risk factors of self-perceived poor health. Self-perceived poor health was related to higher CVD risk but there were substantial gaps between them. Among cardiovascular risk factors, dyslipidemia, obesity, smoking, and a family history of CVD did not affect self-perceived health. Gaps between perceived health and actual CVD risk should be closed to optimize cardiovascular health of South Koreans. Koreans need to increase risk perception to a level commensurate with their actual risk. Healthcare providers should try to provide individuals at increased CVD risk with better information more frequently, especially those who have favorable perceptions of their health but smoke or have elevated cholesterol levels and bodyweight. © 2015 Japan Academy of Nursing Science.

  16. Deep Borehole Field Test Research Activities at LBNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobson, Patrick; Tsang, Chin-Fu; Kneafsey, Timothy

    The goal of the U.S. Department of Energy Used Fuel Disposition’s (UFD) Deep Borehole Field Test is to drill two 5 km large-diameter boreholes: a characterization borehole with a bottom-hole diameter of 8.5 inches and a field test borehole with a bottom-hole diameter of 17 inches. These boreholes will be used to demonstrate the ability to drill such holes in crystalline rocks, effectively characterize the bedrock repository system using geophysical, geochemical, and hydrological techniques, and emplace and retrieve test waste packages. These studies will be used to test the deep borehole disposal concept, which requires a hydrologically isolated environment characterizedmore » by low permeability, stable fluid density, reducing fluid chemistry conditions, and an effective borehole seal. During FY16, Lawrence Berkeley National Laboratory scientists conducted a number of research studies to support the UFD Deep Borehole Field Test effort. This work included providing supporting data for the Los Alamos National Laboratory geologic framework model for the proposed deep borehole site, conducting an analog study using an extensive suite of geoscience data and samples from a deep (2.5 km) research borehole in Sweden, conducting laboratory experiments and coupled process modeling related to borehole seals, and developing a suite of potential techniques that could be applied to the characterization and monitoring of the deep borehole environment. The results of these studies are presented in this report.« less

  17. Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results

    DTIC Science & Technology

    1988-09-01

    Test and Evaluation Report Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results by .0 Joseph J...PROGRAM PROJECT TASK WORK UNIT Washington, D.C. 20361 ELEMENT NO. NO. NO. ACCESSION NO. OMN 1820 11. TITLE (Include Security Classification) TEST AND...EVALUATION OF THE NAVY TECHNICAL INFORMATION PRESENTATION SYSTEM (NTIPS) F-14A FIELD TEST RESULTS 12. PERSONAL AUTHOR(S) Fuller, Joseph F. (DTRC) Post

  18. Computational Investigation of Helical Traveling Wave Tube Transverse RF Field Forces

    NASA Technical Reports Server (NTRS)

    Kory, Carol L.; Dayton, James A.

    1998-01-01

    In a previous study using a fully three-dimensional (3D) helical slow-wave circuit cold- test model it was found, contrary to classical helical circuit analyses, that transverse FF electric fields have significant amplitudes compared with the longitudinal component. The RF fields obtained using this helical cold-test model have been scaled to correspond to those of an actual TWT. At the output of the tube, RF field forces reach 61%, 26% and 132% for radial, azimuthal and longitudinal components, respectively, compared to radial space charge forces indicating the importance of considering them in the design of electron beam focusing.

  19. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  20. Test Bench for Coupling and Shielding Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Jordan, J.; Esteve, V.; Dede, E.; Sanchis, E.; Maset, E.; Ferreres, A.; Ejea, J. B.; Cases, C.

    2016-05-01

    This paper describes a test bench for training purposes, which uses a magnetic field generator to couple this magnetic field to a victim circuit. It can be very useful to test for magnetic susceptibility as well. The magnetic field generator consists of a board, which generates a variable current that flows into a printed circuit board with spiral tracks (noise generator). The victim circuit consists of a coaxial cable concentric with the spiral tracks and its generated magnetic field. The coaxial cable is part of a circuit which conducts a signal produced by a signal generator and a resistive load. In the paper three cases are studied. First, the transmitted signal from the signal generator uses the central conductor of the coaxial cable and the shield is floating. Second, the shield is short circuited at its ends (and thus forming a loop). Third, when connecting the shield in series with the inner conductor and therefore having the current flowing into the coax via the inner conductor and returning via the shield.

  1. IN SITU FIELD TESTING OF PROCESSES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J.S.Y. YANG

    2004-11-08

    The purpose of this scientific analysis report is to update and document the data and subsequent analyses from ambient field-testing activities performed in underground drifts and surface-based boreholes through unsaturated zone (UZ) tuff rock units. In situ testing, monitoring, and associated laboratory studies are conducted to directly assess and evaluate the waste emplacement environment and the natural barriers to radionuclide transport at Yucca Mountain. This scientific analysis report supports and provides data to UZ flow and transport model reports, which in turn contribute to the Total System Performance Assessment (TSPA) of Yucca Mountain, an important document for the license applicationmore » (LA). The objectives of ambient field-testing activities are described in Section 1.1. This report is the third revision (REV 03), which supercedes REV 02. The scientific analysis of data for inputs to model calibration and validation as documented in REV 02 were developed in accordance with the Technical Work Plan (TWP) ''Technical Work Plan for: Performance Assessment Unsaturated Zone'' (BSC 2004 [DIRS 167969]). This revision was developed in accordance with the ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Section 1.2.4) for better integrated, consistent, transparent, traceable, and more complete documentation in this scientific analysis report and associated UZ flow and transport model reports. No additional testing or analyses were performed as part of this revision. The list of relevant acceptance criteria is provided by ''Technical Work Plan for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654]), Table 3-1. Additional deviations from the TWP regarding the features, events, and processes (FEPs) list are discussed in Section 1.3. Documentation in this report includes descriptions of how, and under what conditions, the tests were conducted. The descriptions

  2. Field joint protection system rain qualification test report

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    This report documents the procedures, performance, and results obtained from the Field Joint Protection System (FJPS) rain test. This test was performed to validate that the flight configuration FJPS prevents the accumulation of moisture in the redesigned solid rocket motor (RSRM) field joints when subjected to simulated prelaunch natural rain environments. The FJPS test article was exposed to rain simulation for approximately 50 minutes. During the test, water entered through the open upper end of the systems tunnel and was funneled down between the tunnel and case. A sealant void at the moisture seal butt splice allowed this water to flow underneath the FJPS. The most likely cause of voids was improper bondline preparation, particularly on the moisture seal surface. In total, water penetrated underneath approximately 60 percent of the FJPS circumference. Because the test article was substantially different from flight configuration (no systems tunnel closeout), results of this test will not affect current flight motors. Due to the omission of systems tunnel covers and systems tunnel floor plate closeout, the test assembly was not representative of flight hardware and resulted in a gross overtest. It is therefore recommended that the test be declared void. It is also recommended that the test be repeated with a complete closeout of the systems tunnel, sealed systems tunnel ends, and improved adhesive bondline preparation.

  3. Genesis field operational test : final evaluation report

    DOT National Transportation Integrated Search

    1997-09-01

    This document is the Final Evaluation Report for the Genesis Advanced Traveler Information System (ATIS) Field Operational Test (FOT). Genesis was one of the early projects sponsored by the US Department of Transportation (USDOT) Intelligent Transpor...

  4. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    DOT National Transportation Integrated Search

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  5. Field evaluation of ventilation system performance in enclosed parking garages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ayari, A.M.; Grot, D.A.; Krarti, M.

    2000-07-01

    This paper summarizes the results of a field study to determine the ventilation requirements and the contaminant levels in existing enclosed parking garages. The testing was conducted in seven parking garages with different sizes, traffic flow patterns, vehicle types, and locations. In particular, the study compares the actual ventilation rates measured using the tracer gas technique with the ventilation requirements of ANSI/ASHRAE Standard 62-1989. In addition, the field test evaluated the effectiveness of the existing ventilation systems in maintaining acceptable contaminant levels within enclosed parking garages.

  6. Relative Cost and Training Effectiveness of the 6883 Three-Dimensional Simulator and Actual Equipment.

    DTIC Science & Technology

    1980-09-01

    evaluated. The objectis e of this study was to isolate classroom and field performance differences as a function of the training equipnment used and to...THIS PAtICmmUn bat. Saelrwo Item 20 (Continued): ausperviser followup questionnaires were administered in the field to provide additional feedback about...competent maintenance technicians to the field . As a train- ing device, actual equipment does not readily permit the controlled presentation of

  7. The nonrelativistic limit of (central-extended) Poincaré group and some consequences for quantum actualization

    NASA Astrophysics Data System (ADS)

    Ardenghi, Juan S.; Castagnino, M.; Campoamor-Stursberg, R.

    2009-10-01

    The nonrelativistic limit of the centrally extended Poincaré group is considered and their consequences in the modal Hamiltonian interpretation of quantum mechanics are discussed [O. Lombardi and M. Castagnino, Stud. Hist. Philos. Mod. Phys 39, 380 (2008); J. Phys, Conf. Ser. 128, 012014 (2008)]. Through the assumption that in quantum field theory the Casimir operators of the Poincaré group actualize, the nonrelativistic limit of the latter group yields to the actualization of the Casimir operators of the Galilei group, which is in agreement with the actualization rule of previous versions of modal Hamiltonian interpretation [Ardenghi et al., Found. Phys. (submitted)].

  8. Testing an Energy Balance Model for Estimating Actual Evapotranspiration Using Remotely Sensed Data. [Hannover, West Germany barley and wheat fields

    NASA Technical Reports Server (NTRS)

    Gurney, R. J.; Camillo, P. J.

    1985-01-01

    An energy-balance model is used to estimate daily evapotranspiration for 3 days for a barley field and a wheat field near Hannover, Federal Republic of Germany. The model was calibrated using once-daily estimates of surface temperatures, which may be remotely sensed. The evaporation estimates were within the 95% error bounds of independent eddy correlation estimates for the daytime periods for all three days for both sites, but the energy-balance estimates are generally higher; it is unclear which estimate is biassed. Soil moisture in the top 2 cm of soil, which may be remotely sensed, may be used to improve these evaporation estimates under partial ground cover. Sensitivity studies indicate the amount of ground data required is not excessive.

  9. Goldstone field test activities: Target search

    NASA Technical Reports Server (NTRS)

    Tarter, J.

    1986-01-01

    In March of this year prototype SETI equipment was installed at DSS13, the 26 meter research and development antenna at NASA's Goldstone complex of satellite tracking dishes. The SETI equipment will remain at this site at least through the end of the summer so that the hardware and software developed for signal detection and recognition can be fully tested in a dynamic observatory environment. The field tests are expected to help understand which strategies for observing and which signal recognition algorithms perform best in the presence of strong man-made interfering signals (RFI) and natural astronomical sources.

  10. A new method of field MRTD test

    NASA Astrophysics Data System (ADS)

    Chen, Zhibin; Song, Yan; Liu, Xianhong; Xiao, Wenjian

    2014-09-01

    MRTD is an important indicator to measure the imaging performance of infrared camera. In the traditional laboratory test, blackbody is used as simulated heat source which is not only expensive and bulky but also difficult to meet field testing requirements of online automatic infrared camera MRTD. To solve this problem, this paper introduces a new detection device for MRTD, which uses LED as a simulation heat source and branded plated zinc sulfide glass carved four-bar target as a simulation target. By using high temperature adaptability cassegrain collimation system, the target is simulated to be distance-infinite so that it can be observed by the human eyes to complete the subjective test, or collected to complete objective measurement by image processing. This method will use LED to replace blackbody. The color temperature of LED is calibrated by thermal imager, thereby, the relation curve between the LED temperature controlling current and the blackbody simulation temperature difference is established, accurately achieved the temperature control of the infrared target. Experimental results show that the accuracy of the device in field testing of thermal imager MRTD can be limited within 0.1K, which greatly reduces the cost to meet the project requirements with a wide application value.

  11. Automotive collision avoidance system field operational test

    DOT National Transportation Integrated Search

    2005-03-01

    The Automotive Collision Avoidance System field operational test (or ACAS FOT) program was led by General Motors (GM) under a cooperative agreement with the U.S. Department of Transportation. This report summarizes the activities of the entire progra...

  12. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  13. Aircraft electric field measurements: Calibration and ambient field retrieval

    NASA Technical Reports Server (NTRS)

    Koshak, William J.; Bailey, Jeff; Christian, Hugh J.; Mach, Douglas M.

    1994-01-01

    An aircraft locally distorts the ambient thundercloud electric field. In order to determine the field in the absence of the aircraft, an aircraft calibration is required. In this work a matrix inversion method is introduced for calibrating an aircraft equipped with four or more electric field sensors and a high-voltage corona point that is capable of charging the aircraft. An analytic, closed form solution for the estimate of a (3 x 3) aircraft calibration matrix is derived, and an absolute calibration experiment is used to improve the relative magnitudes of the elements of this matrix. To demonstrate the calibration procedure, we analyze actual calibration date derived from a Lear jet 28/29 that was equipped with five shutter-type field mill sensors (each with sensitivities of better than 1 V/m) located on the top, bottom, port, starboard, and aft positions. As a test of the calibration method, we analyze computer-simulated calibration data (derived from known aircraft and ambient fields) and explicitly determine the errors involved in deriving the variety of calibration matrices. We extend our formalism to arrive at an analytic solution for the ambient field, and again carry all errors explicitly.

  14. San Diego field operational test of smart call boxes : institutional issues

    DOT National Transportation Integrated Search

    1997-01-01

    Important institutional lessons learned in the course of the San Diego smart call box field operational test are presented. These lessons relate both to the conduct of the field test itself and to requirements for deployment of intelligent transporta...

  15. US Highway 84 chip seal field trials and laboratory test results.

    DOT National Transportation Integrated Search

    2009-03-23

    This report contains laboratory and field testing of US Highway 84 in Lincoln county Mississippi. A full scale field test consisting of seven polymer modified asphalt emulsions and a CRS-2 control emulsion was constructed in September of 1989 and sub...

  16. Evaluation of TravInfo field operational test

    DOT National Transportation Integrated Search

    2000-04-25

    This document constitutes the final report of the evaluation of the TravInfo field operational test. TravInfo is a regional traveler information system in operation in the San Francisco Bay Area. The focus of the evaluation was on three areas: instit...

  17. Field test of coordinated ramp metering (CRM).

    DOT National Transportation Integrated Search

    2017-03-15

    This project has focused on field implementation and testing of a Coordinated Ramp Metering (CRM) algorithm at California State Route 99 : Northbound corridor in Sacramento between Calvine Road and the SR50 interchange after 12th Ave. It is a 9 mile ...

  18. A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-14-2-0195 TITLE: A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis PRINCIPAL INVESTIGATOR...Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...Month % completion Aim 1: To use simulated field conditions to optimize and produce the established RPA lateral flow diagnostic test for POC

  19. Actual Risk and Perceived Risk: Implications for Teaching Judgement and Decision-Making to Leaders.

    ERIC Educational Resources Information Center

    Guthrie, Steven P.

    This paper begins by presenting three tests, which are included in the appendix, of one's awareness of physical risks. This exercise leads to a discussion of the differences between actual and perceived risk, why people participate in outdoor activities, and the inaccurate perception of actual risks. Complicating the issue of accurately perceiving…

  20. Exaggerating Accessible Differences: When Gender Stereotypes Overestimate Actual Group Differences.

    PubMed

    Eyal, Tal; Epley, Nicholas

    2017-09-01

    Stereotypes are often presumed to exaggerate group differences, but empirical evidence is mixed. We suggest exaggeration is moderated by the accessibility of specific stereotype content. In particular, because the most accessible stereotype contents are attributes perceived to differ between groups, those attributes are most likely to exaggerate actual group differences due to regression to the mean. We tested this hypothesis using a highly accessible gender stereotype: that women are more socially sensitive than men. We confirmed that the most accessible stereotype content involves attributes perceived to differ between groups (pretest), and that these stereotypes contain some accuracy but significantly exaggerate actual gender differences (Experiment 1). We observe less exaggeration when judging less accessible stereotype content (Experiment 2), or when judging individual men and women (Experiment 3). Considering the accessibility of specific stereotype content may explain when stereotypes exaggerate actual group differences and when they do not.

  1. The Center-TRACON Automation System: Simulation and field testing

    NASA Technical Reports Server (NTRS)

    Denery, Dallas G.; Erzberger, Heinz

    1995-01-01

    A new concept for air traffic management in the terminal area, implemented as the Center-TRACON Automation System, has been under development at NASA Ames in a cooperative program with the FAA since 1991. The development has been strongly influenced by concurrent simulation and field site evaluations. The role of simulation and field activities in the development process will be discussed. Results of recent simulation and field tests will be presented.

  2. Field evaluation of a behavioral test battery for DWI

    DOT National Transportation Integrated Search

    1983-09-01

    This paper presents initial findings from a recently conducted field evaluation of a sobriety test battery. Police officers from four jurisdictions were trained in the use of the sobriety test battery. They then administered the battery to drivers st...

  3. Preliminary Report on Free Flight Tests

    NASA Technical Reports Server (NTRS)

    Warner, E P; Norton, F H

    1920-01-01

    Results are presented for a series of tests made by the Advisory Committee's staff at Langley Field during the summer of 1919 with the objectives of determining the characteristics of airplanes in flight and the extent to which the actual characteristics differ from those predicted from tests on models in the wind tunnel, and of studying the balance of the machines and the forces which must be applied to the controls in order to maintain longitudinal equilibrium.

  4. Environmental testing of terrestrial flat plate photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Hoffman, A.; Griffith, J.

    1979-01-01

    The Low-Cost Solar Array (LSA) Project at the Jet Propulsion Laboratory has as one objective: the development and implementation of environmental tests for flat plate photovoltaic modules as part of the Department of Energy's terrestrial photovoltaic program. Modules procured under this program have been subjected to a variety of laboratory tests intended to simulate service environments, and the results of these tests have been compared to available data from actual field service. This comparison indicates that certain tests (notably temperature cycling, humidity cycling, and cyclic pressure loading) are effective indicators of some forms of field failures. Other tests have yielded results useful in formulating module design guidelines. Not all effects noted in field service have been successfully reproduced in the laboratory, however, and work is continuing in order to improve the value of the test program as a tool for evaluating module design and workmanship. This paper contains a review of these ongoing efforts and an assessment of significant test results to date.

  5. Actual drawing of histological images improves knowledge retention.

    PubMed

    Balemans, Monique C M; Kooloos, Jan G M; Donders, A Rogier T; Van der Zee, Catharina E E M

    2016-01-01

    Medical students have to process a large amount of information during the first years of their study, which has to be retained over long periods of nonuse. Therefore, it would be beneficial when knowledge is gained in a way that promotes long-term retention. Paper-and-pencil drawings for the uptake of form-function relationships of basic tissues has been a teaching tool for a long time, but now seems to be redundant with virtual microscopy on computer-screens and printers everywhere. Several studies claimed that, apart from learning from pictures, actual drawing of images significantly improved knowledge retention. However, these studies applied only immediate post-tests. We investigated the effects of actual drawing of histological images, using randomized cross-over design and different retention periods. The first part of the study concerned esophageal and tracheal epithelium, with 384 medical and biomedical sciences students randomly assigned to either the drawing or the nondrawing group. For the second part of the study, concerning heart muscle cells, students from the previous drawing group were now assigned to the nondrawing group and vice versa. One, four, and six weeks after the experimental intervention, the students were given a free recall test and a questionnaire or drawing exercise, to determine the amount of knowledge retention. The data from this study showed that knowledge retention was significantly improved in the drawing groups compared with the nondrawing groups, even after four or six weeks. This suggests that actual drawing of histological images can be used as a tool to improve long-term knowledge retention. © 2015 American Association of Anatomists.

  6. Impact of Acoustic Standing Waves on Structural Responses: Reverberant Acoustic Testing (RAT) vs. Direct Field Acoustic Testing (DFAT)

    NASA Technical Reports Server (NTRS)

    Kolaini, Ali R.; Doty, Benjamin; Chang, Zensheu

    2012-01-01

    Loudspeakers have been used for acoustic qualification of spacecraft, reflectors, solar panels, and other acoustically responsive structures for more than a decade. Limited measurements from some of the recent speaker tests used to qualify flight hardware have indicated significant spatial variation of the acoustic field within the test volume. Also structural responses have been reported to differ when similar tests were performed using reverberant chambers. To address the impact of non-uniform acoustic field on structural responses, a series of acoustic tests were performed using a flat panel and a 3-ft cylinder exposed to the field controlled by speakers and repeated in a reverberant chamber. The speaker testing was performed using multi-input-single-output (MISO) and multi-input-multi-output (MIMO) control schemes with and without the test articles. In this paper the spatial variation of the acoustic field due to acoustic standing waves and their impacts on the structural responses in RAT and DFAT (both using MISO and MIMO controls for DFAT) are discussed in some detail.

  7. Full-Scale Field Test of Wake Steering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, Paul; Annoni, Jennifer; Scholbrock, Andrew

    Wind farm control, in which turbine controllers are coordinated to improve farmwide performance, is an active field of research. One form of wind farm control is wake steering, in which a turbine is yawed to the inflow to redirect its wake away from downstream turbines. Wake steering has been studied in depth in simulations as well as in wind tunnels and scaled test facilities. This work performs a field test of wake steering on a full-scale turbine. In the campaign, the yaw controller of the turbine has been set to track different yaw misalignment set points while a nacelle-mounted lidarmore » scans the wake at several ranges downwind. The lidar measurements are combined with turbine data, as well as measurements of the inflow made by a highly instrumented meteorological mast. In conclusion, these measurements are then compared to the predictions of a wind farm control-oriented model of wakes.« less

  8. Full-Scale Field Test of Wake Steering

    DOE PAGES

    Fleming, Paul; Annoni, Jennifer; Scholbrock, Andrew; ...

    2017-06-13

    Wind farm control, in which turbine controllers are coordinated to improve farmwide performance, is an active field of research. One form of wind farm control is wake steering, in which a turbine is yawed to the inflow to redirect its wake away from downstream turbines. Wake steering has been studied in depth in simulations as well as in wind tunnels and scaled test facilities. This work performs a field test of wake steering on a full-scale turbine. In the campaign, the yaw controller of the turbine has been set to track different yaw misalignment set points while a nacelle-mounted lidarmore » scans the wake at several ranges downwind. The lidar measurements are combined with turbine data, as well as measurements of the inflow made by a highly instrumented meteorological mast. In conclusion, these measurements are then compared to the predictions of a wind farm control-oriented model of wakes.« less

  9. Field testing energy-saving hermetic compressors in residential refrigerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauber, R.S.; Middleton, M.G.

    The design of an energy-saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy-saving compressor. The preparation of the refrigerators used in the field test is discussed, along with the criteria used in selecting the instrumentation for the project. Results of the energy-saving compressor in the field test, along with a comparison to a standard production compressor, are presented. Some conclusions are drawn, basedmore » on the data, in relation to important factors in residential refrigerator power consumption.« less

  10. Field testing energy-saving hermetic compressors in residential refrigerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauber, R.S.; Middleton, M.G.

    The design of an energy saving compressor for low back pressure applications is reviewed. Calorimeter performance results are stated for two sizes of the efficient design and compared with performance test results for a standard compressor. Power consumption of a refrigerator-freezer is given with a standard compressor and with the energy saving compressor. The preparation of the refrigerators used in the field test are discussed along with the criteria used in selecting the instrumentation for the project. Results of the energy saving compressor in the field test along with a comparison to a standard production compressor are presented. Some conclusionsmore » are drawn, based on the data, in relation to important factors in residential refrigerator power consumption.« less

  11. Marijuana and actual driving performance

    DOT National Transportation Integrated Search

    1993-11-01

    This report concerns the effects of marijuana smoking on actual driving performance. It presents the results of one pilot and three actual driving studies. The pilot study's major purpose was to establish the THC dose current marijuana users smoke to...

  12. Prototype Engineered Barrier System Field Test (PEBSFT); Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez, A.L.; Buscheck, T.; Carlson, R.

    1991-08-01

    This final report represents a summary of data and interpretations obtained from the Prototype Engineered Barrier System Field Test (PEBSFT) performed in G-Tunnel within the Nevada Test Site. The PEBSFT was conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for future field tests that will be conducted in the Exploratory Studies Facilities (ESF) at Yucca Mountain. The primary objective of the test was to provide a basis for determining whether tests planned for the ESF have the potential to be successful. Chapter 1 on high frequency electromagnetic tomography discusses the rock mass electromagnetic permittivity andmore » attenuation rate changes that were measured to characterize the water distribution in the near field of a simulated waste container. The data are used to obtain quantitative estimates of how the moisture content in the rock mass changes during heating and to infer properties of the spatial variability of water distribution, leading to conclusions about the role of fractures in the system. Chapter 2 discusses the changes in rock moisture content detected by the neutron logging probe. Chapter 3 permeability tests discusses the characterization of the in-situ permeability of the fractured tuff around the borehole. The air permeability testing apparatus, the testing procedures, and the data analysis are presented. Chapter 4 describes the moisture collection system installed in the heater borehole to trap and measure the moisture volumes. Chapter 5 describes relative humidity measurements made with the thermocouple psychrometer and capacitance sensors. Chapter 6 discusses gas pressure measurements in the G-Tunnel, addressing the calibration and installation of piezoresistive-gaged transducers. Chapter 7 describes the calibration and installation of thermocouples for temperature measurements. Chapter 8 discusses the results of the PEBSFT.« less

  13. Comparison of simulated and actual wind shear radar data products

    NASA Technical Reports Server (NTRS)

    Britt, Charles L.; Crittenden, Lucille H.

    1992-01-01

    Prior to the development of the NASA experimental wind shear radar system, extensive computer simulations were conducted to determine the performance of the radar in combined weather and ground clutter environments. The simulation of the radar used analytical microburst models to determine weather returns and synthetic aperture radar (SAR) maps to determine ground clutter returns. These simulations were used to guide the development of hazard detection algorithms and to predict their performance. The structure of the radar simulation is reviewed. Actual flight data results from the Orlando and Denver tests are compared with simulated results. Areas of agreement and disagreement of actual and simulated results are shown.

  14. 7 CFR 1437.101 - Actual production history.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Actual production history. 1437.101 Section 1437.101... Determining Yield Coverage Using Actual Production History § 1437.101 Actual production history. Actual production history (APH) is the unit's record of crop yield by crop year for the APH base period. The APH...

  15. 7 CFR 1437.101 - Actual production history.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Actual production history. 1437.101 Section 1437.101... Determining Yield Coverage Using Actual Production History § 1437.101 Actual production history. Actual production history (APH) is the unit's record of crop yield by crop year for the APH base period. The APH...

  16. 7 CFR 1437.101 - Actual production history.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 10 2014-01-01 2014-01-01 false Actual production history. 1437.101 Section 1437.101... Determining Yield Coverage Using Actual Production History § 1437.101 Actual production history. Actual production history (APH) is the unit's record of crop yield by crop year for the APH base period. The APH...

  17. 7 CFR 1437.101 - Actual production history.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 10 2013-01-01 2013-01-01 false Actual production history. 1437.101 Section 1437.101... Determining Yield Coverage Using Actual Production History § 1437.101 Actual production history. Actual production history (APH) is the unit's record of crop yield by crop year for the APH base period. The APH...

  18. 7 CFR 1437.101 - Actual production history.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Actual production history. 1437.101 Section 1437.101... Determining Yield Coverage Using Actual Production History § 1437.101 Actual production history. Actual production history (APH) is the unit's record of crop yield by crop year for the APH base period. The APH...

  19. A coupled remote sensing and simplified surface energy balance approach to estimate actual evapotranspiration from irrigated fields

    USGS Publications Warehouse

    Senay, G.B.; Budde, Michael; Verdin, J.P.; Melesse, Assefa M.

    2007-01-01

    Accurate crop performance monitoring and production estimation are critical for timely assessment of the food balance of several countries in the world. Since 2001, the Famine Early Warning Systems Network (FEWS NET) has been monitoring crop performance and relative production using satellite-derived data and simulation models in Africa, Central America, and Afghanistan where ground-based monitoring is limited because of a scarcity of weather stations. The commonly used crop monitoring models are based on a crop water-balance algorithm with inputs from satellite-derived rainfall estimates. These models are useful to monitor rainfed agriculture, but they are ineffective for irrigated areas. This study focused on Afghanistan, where over 80 percent of agricultural production comes from irrigated lands. We developed and implemented a Simplified Surface Energy Balance (SSEB) model to monitor and assess the performance of irrigated agriculture in Afghanistan using a combination of 1-km thermal data and 250m Normalized Difference Vegetation Index (NDVI) data, both from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor. We estimated seasonal actual evapotranspiration (ETa) over a period of six years (2000-2005) for two major irrigated river basins in Afghanistan, the Kabul and the Helmand, by analyzing up to 19 cloud-free thermal and NDVI images from each year. These seasonal ETa estimates were used as relative indicators of year-to-year production magnitude differences. The temporal water-use pattern of the two irrigated basins was indicative of the cropping patterns specific to each region. Our results were comparable to field reports and to estimates based on watershed-wide crop water-balance model results. For example, both methods found that the 2003 seasonal ETa was the highest of all six years. The method also captured water management scenarios where a unique year-to-year variability was identified in addition to water-use differences between

  20. A Coupled Remote Sensing and Simplified Surface Energy Balance Approach to Estimate Actual Evapotranspiration from Irrigated Fields

    PubMed Central

    Senay, Gabriel B.; Budde, Michael; Verdin, James P.; Melesse, Assefa M.

    2007-01-01

    Accurate crop performance monitoring and production estimation are critical for timely assessment of the food balance of several countries in the world. Since 2001, the Famine Early Warning Systems Network (FEWS NET) has been monitoring crop performance and relative production using satellite-derived data and simulation models in Africa, Central America, and Afghanistan where ground-based monitoring is limited because of a scarcity of weather stations. The commonly used crop monitoring models are based on a crop water-balance algorithm with inputs from satellite-derived rainfall estimates. These models are useful to monitor rainfed agriculture, but they are ineffective for irrigated areas. This study focused on Afghanistan, where over 80 percent of agricultural production comes from irrigated lands. We developed and implemented a Simplified Surface Energy Balance (SSEB) model to monitor and assess the performance of irrigated agriculture in Afghanistan using a combination of 1-km thermal data and 250-m Normalized Difference Vegetation Index (NDVI) data, both from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor. We estimated seasonal actual evapotranspiration (ETa) over a period of six years (2000-2005) for two major irrigated river basins in Afghanistan, the Kabul and the Helmand, by analyzing up to 19 cloud-free thermal and NDVI images from each year. These seasonal ETa estimates were used as relative indicators of year-to-year production magnitude differences. The temporal water-use pattern of the two irrigated basins was indicative of the cropping patterns specific to each region. Our results were comparable to field reports and to estimates based on watershed-wide crop water-balance model results. For example, both methods found that the 2003 seasonal ETa was the highest of all six years. The method also captured water management scenarios where a unique year-to-year variability was identified in addition to water-use differences between

  1. Hazardous material transportation safety and security field operational test final detailed test plans : executive summary

    DOT National Transportation Integrated Search

    2003-09-16

    The objective of this Hazardous Material (HazMat) Transportation Safety and Security Field Operational Test (FOT) Final Detailed Test Plans evaluation is to measure the impact of technology solutions on the safety, security, and operational efficienc...

  2. 40 CFR 1065.295 - PM inertial balance for field-testing analysis.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false PM inertial balance for field-testing... inertial balance for field-testing analysis. (a) Application. You may use an inertial balance to quantify... balance that meets the specifications in Table 1 of § 1065.205. Note that your balance-based system must...

  3. 40 CFR 1065.295 - PM inertial balance for field-testing analysis.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false PM inertial balance for field-testing... inertial balance for field-testing analysis. (a) Application. You may use an inertial balance to quantify... balance that meets the specifications in Table 1 of § 1065.205. Note that your balance-based system must...

  4. Travel Time Data Collection Field Tests - Lessons Learned

    DOT National Transportation Integrated Search

    1999-06-28

    The Los Angeles Spread Spectrum Radio (SSR) Traffic Signal Interconnect Field Operational Test (FOT) investigated the feasibility of using wireless communications as an alternative to traditional hard-wire interconnection, to extend the coverage of c...

  5. Eyewitness identification in actual criminal cases: an archival analysis.

    PubMed

    Behrman, B W; Davey, S L

    2001-10-01

    This study analyzed 271 actual police cases in order to address several prevalent issues in the eyewitness literature. Suspect identification (SI) rates were obtained for 289 photographic lineups, 258 field showups, 58 live lineups, and 66 lineup identifications preceded by earlier identifications. SI rates were assessed for 3 levels of extrinsic evidence: no extrinsic evidence, evidence of minimal probative value, and evidence of substantial probative value. The SI rates for the photographic lineups were assessed as a function of delay, same vs. cross-race conditions, witness type, and weapon presence. SI rates declined significantly over time; SI rates were significantly greater for the same-race condition. SI rates were much greater for field showups than photographic lineups, 76% vs. 48%. The SI rates for the field showups did not vary as a function of eyewitness conditions. The relation between confidence and suspect/foil identifications for the live lineups was significant and moderately high. The utility of archival identification studies for eyewitness testimony research is discussed.

  6. ''Football'' test coil: a simulated service test of internally-cooled, cabled superconductor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marston, P.G.; Iwasa, Y.; Thome, R.J.

    Internally-cooled, cabled superconductor, (ICCS), appears from small-scale tests to be a viable alternative to pool-boiling cooled superconductors for large superconducting magnets. Potential advantages may include savings in helium inventory, smaller structure and ease of fabrication. Questions remain, however, about the structural performance of these systems. The ''football'' test coil has been designed to simulate the actual ''field-current-stress-thermal'' operating conditions of a 25 ka ICCS in a commercial scale MHD magnet. The test procedure will permit demonstration of the 20 year cyclic life of such a magnet in less than 20 days. This paper describes the design, construction and test ofmore » that coil which is wound of copper-stabilized niobium-titanium cable in steel conduit. 2 refs.« less

  7. Geological Characterization of Remote Field Sites Using Visible and Infrared Spectroscopy: Results from the 1999 Marsokhod Field Test

    NASA Technical Reports Server (NTRS)

    Johnson, J. R.; Ruff, S. W.; Moersch, J.; Roush, T.; Horton, K.; Bishop, J.; Cabrol, N. A.; Cockell, C.; Gazis, P.; Newsom, H. E.

    2000-01-01

    The 1999 Marsokhod Field Experiment (MFE) provided an opportunity to test the suitability of rover-borne visible/near-infrared and thermal infrared field spectrometers to contribute to the remote geological exploration of a Mars analog field site.

  8. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  9. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  10. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  11. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  12. 40 CFR 270.63 - Permits for land treatment demonstrations using field test or laboratory analyses.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... demonstrations using field test or laboratory analyses. 270.63 Section 270.63 Protection of Environment... using field test or laboratory analyses. (a) For the purpose of allowing an owner or operator to meet... the field test or laboratory analyses, or as a two-phase facility permit covering the field tests, or...

  13. Smart Park : Truck Parking Field Operation Test Results

    DOT National Transportation Integrated Search

    2011-10-15

    As part of its SmartPark program, the Federal Motor Carrier Safety Administration (FMCSA) conducted a field operations test of two technologies, video imaging and magnetometry, to assess their suitability for determining the occupancy of truck parkin...

  14. Intelligent cruise control field operational test : interim report

    DOT National Transportation Integrated Search

    1997-03-01

    This interim document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The overarching goal of the work is to characterize safety and comfort issues that are fundamenta...

  15. Statistical analysis of Turbine Engine Diagnostic (TED) field test data

    NASA Astrophysics Data System (ADS)

    Taylor, Malcolm S.; Monyak, John T.

    1994-11-01

    During the summer of 1993, a field test of turbine engine diagnostic (TED) software, developed jointly by U.S. Army Research Laboratory and the U.S. Army Ordnance Center and School, was conducted at Fort Stuart, GA. The data were collected in conformance with a cross-over design, some of whose considerations are detailed. The initial analysis of the field test data was exploratory, followed by a more formal investigation. Technical aspects of the data analysis insights that were elicited are reported.

  16. Differential Gender Performance on the Major Field Test-Business

    ERIC Educational Resources Information Center

    Bielinska-Kwapisz, Agnieszka; Brown, F. William

    2013-01-01

    The Major Field Test in Business (MFT-B), a standardized assessment test of business knowledge among undergraduate business seniors, is widely used to measure student achievement. Many previous studies analyzing scores on the MFT-B report gender differences on the exam even after controlling for student's aptitude, general intellectual ability,…

  17. Reactive transport studies at the Raymond Field Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freifeld, B.; Karasaki, K.; Solbau, R.

    1995-12-01

    To ensure the safety of a nuclear waste repository, an understanding of the transport of radionuclides from the repository nearfield to the biosphere is necessary. At the Raymond Field Site, in Raymond, California, tracer tests are being conducted to test characterization methods for fractured media and to evaluate the equipment and tracers that will be used for Yucca Mountain`s fracture characterization. Recent tracer tests at Raymond have used reactive cations to demonstrate transport with sorption. A convective-dispersive model was used to simulate a two-well recirculating test with reasonable results. However, when the same model was used to simulate a radiallymore » convergent tracer test, the model poorly predicted the actual test data.« less

  18. Deep Borehole Field Test Requirements and Controlled Assumptions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, Ernest

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientificmore » characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.« less

  19. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote somemore » relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.« less

  20. Conducting field studies for testing pesticide leaching models

    USGS Publications Warehouse

    Smith, Charles N.; Parrish, Rudolph S.; Brown, David S.

    1990-01-01

    A variety of predictive models are being applied to evaluate the transport and transformation of pesticides in the environment. These include well known models such as the Pesticide Root Zone Model (PRZM), the Risk of Unsaturated-Saturated Transport and Transformation Interactions for Chemical Concentrations Model (RUSTIC) and the Groundwater Loading Effects of Agricultural Management Systems Model (GLEAMS). The potentially large impacts of using these models as tools for developing pesticide management strategies and regulatory decisions necessitates development of sound model validation protocols. This paper offers guidance on many of the theoretical and practical problems encountered in the design and implementation of field-scale model validation studies. Recommendations are provided for site selection and characterization, test compound selection, data needs, measurement techniques, statistical design considerations and sampling techniques. A strategy is provided for quantitatively testing models using field measurements.

  1. Description and test results of a variable speed, constant frequency generating system

    NASA Astrophysics Data System (ADS)

    Brady, F. J.

    1985-12-01

    The variable-speed, constant frequency generating system developed for the Mod-0 wind turbine is presented. This report describes the system as it existed at the conclusion of the project. The cycloconverter control circuit is described including the addition of field-oriented control. The laboratory test and actual wind turbine test results are included.

  2. Initial Field Testing for Forest Tree Improvement

    Treesearch

    C. B. Briscoe

    1963-01-01

    Initial field testing for forest tree improvement is essentially a comparison of genetic groups whether the level of comparison is of species, provenances, or individual trees. A good study design should be as economical as possible, for a given precision, and must be accurate. The latter is simply obtained by restricting the study to a specified set of conditions,...

  3. Psychopharmacology curriculum field test.

    PubMed

    Zisook, Sidney; Balon, Richard; Benjamin, Sheldon; Beresin, Eugene; Goldberg, David A; Jibson, Michael D; Thrall, Grace

    2009-01-01

    As part of an effort to improve psychopharmacology training in psychiatric residency programs, a committee of residency training directors and associate directors adapted an introductory schizophrenia presentation from the American Society of Clinical Psychopharmacology's Model Psychopharmacology Curriculum to develop a multimodal, interactive training module. This article describes the module, its development, and the results of a field trial to test its feasibility and usefulness. Nineteen residency programs volunteered to use the module during the first half of the 2007-2008 academic year. Evaluation consisted of a structured phone interview with the training director or teaching faculty of participating programs during February and early March 2008, asking whether and how they used the curriculum, which components they found most useful, and how it was received by faculty and residents. Of the 19 programs, 14 used the module and 13 participated in the evaluation. The most commonly used components were the pre- and postmodule questions, video-enhanced presentation, standard presentation, problem- or team-based teaching module, and other problem-based teaching modules. No two programs used the module in the same fashion, but it was well received by instructors and residents regardless of use. The results of this field trial suggest that a dynamic, adult-centered curriculum that is exciting, innovative, and informative enough for a wide variety of programs can be developed; however, the development and programmatic barriers require considerable time and effort to overcome.

  4. Evaluation and field load testing of timber railroad bridge

    Treesearch

    Terry J. Wipf; Michael A. Ritter; Douglas L. Wood

    2000-01-01

    Several spans of a 60-year-old open-deck timber railroad bridge on the Southern Pacific Railroad Line (now the Union Pacific) in Southwest Texas were field tested. The tests were conducted with the sponsorship and cooperation of the Association of American Railroads to determine the vertical live load distribution characteristics of the...

  5. Flow-Field Survey in the Test Region of the SR-71 Aircraft Test Bed Configuration

    NASA Technical Reports Server (NTRS)

    Mizukami, Masashi; Jones, Daniel; Weinstock, Vladimir D.

    2000-01-01

    A flat plate and faired pod have been mounted on a NASA SR-71A aircraft for use as a supersonic flight experiment test bed. A test article can be placed on the flat plate; the pod can contain supporting systems. A series of test flights has been conducted to validate this test bed configuration. Flight speeds to a maximum of Mach 3.0 have been attained. Steady-state sideslip maneuvers to a maximum of 2 deg have been conducted, and the flow field in the test region has been surveyed. Two total-pressure rakes, each with two flow-angle probes, have been placed in the expected vicinity of an experiment. Static-pressure measurements have been made on the flat plate. At subsonic and low supersonic speeds with no sideslip, the flow in the surveyed region is quite uniform. During sideslip maneuvers, localized flow distortions impinge on the test region. Aircraft sideslip does not produce a uniform sidewash over the test region. At speeds faster than Mach 1.5, variable-pressure distortions were observed in the test region. Boundary-layer thickness on the flat plate at the rake was less than 2.1 in. For future experiments, a more focused and detailed flow-field survey than this one would be desirable.

  6. Self-Perceived and Actual Motor Competence in Young British Children.

    PubMed

    Duncan, Michael J; Jones, Victoria; O'Brien, Wesley; Barnett, Lisa M; Eyre, Emma L J

    2018-04-01

    Children's perception of their own motor competence is an important correlate of their actual motor competence. The current study is the first to examine this association in British children and the first to use both product and process measures of actual motor competence. A total of 258 children (139 boys and 119 girls; aged 4 to 7 years, Mean = 5.6, SD = .96) completed measures of self-perceived motor competence using the Pictorial Scale for Perceived Movement Competence in Young Children. Children were classified as "Low," "Medium," or "High" perceived competence based on tertile analysis. Actual motor competence was assessed with the Test of Gross Motor Development-2 (a process measure) and a composite of 10-m sprint run time, standing long jump distance, and 1-kg seated medicine ball throw (collectively, a product measure). Data for process and product measures were analyzed using a 2 (sex) × 3 (high, medium, low perceived competence) analysis of covariance, with body mass index, calculated from height and mass, and age controlled. Boys obtained significantly higher scores than girls for both the process ( p = .044) and product ( p = .001) measures of actual motor competence. Boys had significantly ( p = .04) higher scores for perceived competence compared to girls. Compared to children classified as medium and high self-perceived competence, children classified as low self-perceived competence had lower process ( p = .001) and product scores (i.e., medium, p = .009 and high, p = .0001) of actual motor competence. Age ( p = .0001) and body mass index ( p = .0001) were significantly associated with product motor competence. Strategies to enhance actual motor competence may benefit children's self-perceived motor competence.

  7. Dangers of "confirmatory" cancer trials that fail to actually test the original hypothesis.

    PubMed

    Markman, Maurie

    2014-04-01

    The concept of "confirmatory" studies is a standard and important component of the overall clinical trials strategy in oncology. However, it is critical that such studies are similar enough in basic design and how they are conducted that they actually have the realistic potential to confirm, or refute, objectively the findings of the original study. In this commentary, two examples of clinical studies in the gynecologic oncology arena suggested by some to serve as "confirmatory" trials for the original reports demonstrate both the dangers and potential inappropriateness of such conclusions.

  8. Air resistance measurements on actual airplane parts

    NASA Technical Reports Server (NTRS)

    Weiselsberger, C

    1923-01-01

    For the calculation of the parasite resistance of an airplane, a knowledge of the resistance of the individual structural and accessory parts is necessary. The most reliable basis for this is given by tests with actual airplane parts at airspeeds which occur in practice. The data given here relate to the landing gear of a Siemanms-Schuckert DI airplane; the landing gear of a 'Luftfahrzeug-Gesellschaft' airplane (type Roland Dlla); landing gear of a 'Flugzeugbau Friedrichshafen' G airplane; a machine gun, and the exhaust manifold of a 269 HP engine.

  9. In Situ Biological Treatment Test at Kelly Air Force Base. Volume 2. Field Test Results and Cost Model

    DTIC Science & Technology

    1987-07-01

    Groundwater." Developments in Industrial Microbiology, Volume 24, pp. 225-234. Society of Industrial Microbiology, Arlington, Virginia. 18. Product ...ESL-TR-85-52 cv) VOLUME II CN IN SITU BIOLOGICAL TREATMENT TEST AT KELLY AIR FORCE BASE, VOLUME !1: FIELD TEST RESULTS AND COST MODEL R.S. WETZEL...Kelly Air Force Base, Volume II: Field Test Results and Cost Model (UNCLASSIFIED) 12 PERSONAL AUTHOR(S) Roger S. Wetzel, Connie M. Durst, Donald H

  10. Clinical learning environments (actual and expected): perceptions of Iran University of Medical Sciences nursing students

    PubMed Central

    Bigdeli, Shoaleh; Pakpour, Vahid; Aalaa, Maryam; Shekarabi, Robabeh; Sanjari, Mahnaz; Haghani, Hamid; Mehrdad, Neda

    2015-01-01

    Background: Educational clinical environment has an important role in nursing students' learning. Any difference between actual and expected clinical environment will decrease nursing students’ interest in clinical environments and has a negative correlation with their clinical performance. Methods: This descriptive cross-sectional study is an attempt to compare nursing students' perception of the actual and expected status of clinical environments in medical-surgical wards. Participants of the study were 127 bachelor nursing students of Iran University of Medical Sciences in the internship period. Data gathering instruments were a demographic questionnaire (including sex, age, and grade point average), and the Clinical Learning Environment Inventory (CLEI) originally developed by Professor Chan (2001), in which its modified Farsi version (Actual and Preferred forms) consisting 42 items, 6 scales and 7 items per scale was used. Descriptive and inferential statistics (t-test, paired t-test, ANOVA) were used for data analysis through SPSS version 16. Results: The results indicated that there were significant differences between the preferred and actual form in all six scales. In other word, comparing with the actual form, the mean scores of all items in the preferred form were higher. The maximum mean difference was in innovation and the highest mean difference was in involvement scale. Conclusion: It is concluded that nursing students do not have a positive perception of their actual clinical teaching environment and this perception is significantly different from their perception of their expected environment. PMID:26034726

  11. Hazardous material transportation safety and security field operational test beta test and baseline data report : executive summary

    DOT National Transportation Integrated Search

    2003-10-29

    The Beta Test and Baseline Data Collection efforts ensured that the test technologies would successfully operate during the field operational test (FOT) in the designed scenario configurations. These efforts also ensured that FOT systems would succes...

  12. Test Plan of the Anticipatory Wirelss Sensor Network for the Critical Energy Infrastructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlos Rentel

    2006-09-01

    The test plan for the performance of the Anticipatory Wireless Sensor Network (A-WSN) is presented. The results of the test campaigns will be obtained after actual measurements are taken in the field with the Wireless Sensor Network developed by The Innovation Center-Eaton Corp., and the Anticipatory algorithms developed by ORNL.

  13. 40 CFR 35.2211 - Field testing for Innovative and Alternative Technology Report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Treatment Works § 35.2211 Field testing for Innovative and Alternative Technology Report. The grantee shall... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Field testing for Innovative and Alternative Technology Report. 35.2211 Section 35.2211 Protection of Environment ENVIRONMENTAL PROTECTION...

  14. 40 CFR 35.2211 - Field testing for Innovative and Alternative Technology Report.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Treatment Works § 35.2211 Field testing for Innovative and Alternative Technology Report. The grantee shall... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Field testing for Innovative and Alternative Technology Report. 35.2211 Section 35.2211 Protection of Environment ENVIRONMENTAL PROTECTION...

  15. 40 CFR 35.2211 - Field testing for Innovative and Alternative Technology Report.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Treatment Works § 35.2211 Field testing for Innovative and Alternative Technology Report. The grantee shall... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Field testing for Innovative and Alternative Technology Report. 35.2211 Section 35.2211 Protection of Environment ENVIRONMENTAL PROTECTION...

  16. 40 CFR 35.2211 - Field testing for Innovative and Alternative Technology Report.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Treatment Works § 35.2211 Field testing for Innovative and Alternative Technology Report. The grantee shall... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Field testing for Innovative and Alternative Technology Report. 35.2211 Section 35.2211 Protection of Environment ENVIRONMENTAL PROTECTION...

  17. 40 CFR 35.2211 - Field testing for Innovative and Alternative Technology Report.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Treatment Works § 35.2211 Field testing for Innovative and Alternative Technology Report. The grantee shall... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Field testing for Innovative and Alternative Technology Report. 35.2211 Section 35.2211 Protection of Environment ENVIRONMENTAL PROTECTION...

  18. The Relationship of Self-Disclosure to Personality, Adjustment and Self-Actualization

    ERIC Educational Resources Information Center

    Lombardo, John P.; Fantasia, Saverio C.

    1976-01-01

    Tested the hypothesis that a high level of self-disclosure is indicative of psychological adjustment and self-actualization. The self-disclosure scale, Social Avoidance and Distress, Fear of Negative Evaluation, Alienation and Repression-Sensitization scales were administered to 60 introductory psychology students. (Editor/RK)

  19. Does nurses'perceived burn prevention knowledge and ability to teach burn prevention correlate with their actual burn prevention knowledge?

    PubMed

    Lehna, Carlee; Myers, John

    2010-01-01

    The purpose of this study was to explore the relationship among nurses'perceived burn prevention knowledge, their perceived ability to teach about burn prevention, and their actual burn prevention knowledge and to test if their actual burn knowledge could be predicted by these perceived measures. A two-page, anonymous survey that included a 10-item burn prevention knowledge test and an assessment of nurses'perceived knowledge of burn prevention and their perceived ability to teach burn prevention was administered to 313 nurses. Actual burn prevention knowledge was determined and the correlation among actual burn prevention knowledge, perceived knowledge, and perceived ability to teach was determined. Differences in these outcome variables based on specialty area were tested using analysis of variance techniques. Generalized linear modeling techniques were used to investigate which variables significantly predict a nurse's actual burn prevention knowledge. Test for interaction effects were performed, and significance was set at .05. Responding nurses (N = 265) described practicing in a variety of settings, such as pediatric settings (40.2%, n = 105), emergency departments (25.4%, n = 86), medical/surgical settings (8.4%, n = 22), and one pediatric burn setting (4.1%, n = 14), with all specialty areas as having similar actual burn prevention knowledge (P = .052). Seventy-seven percent of the nurses said they never taught about burn prevention (n = 177). Perceived knowledge and actual knowledge (r = .124, P = .046) as well as perceived knowledge and perceived ability were correlated (r = .799, P < .001). Significant predictors of actual knowledge were years in practice (beta = -0.063, P = .034), years in current area (beta = 0.072, P = .003), perceived knowledge (beta = 0.109, P = .042), and perceived ability (beta = 0.137, P = .019). All nurses, regardless of specialty area, have poor burn prevention knowledge, which is correlated with their perceived lack of

  20. How important is young children's actual and perceived movement skill competence to their physical activity?

    PubMed

    Slykerman, Sarah; Ridgers, Nicola D; Stevenson, Christopher; Barnett, Lisa M

    2016-06-01

    To determine the associations between young children's actual and perceived object control and locomotor skills and physical activity and whether associations differ by sex. Cross sectional study. A total of 136 children consented. Children had actual skill (Test of Gross Motor Development-2), perceived skill (Pictorial Scale of Perceived Movement Skill Competence for Young Children), and moderate- to vigorous-intensity physical activity (MVPA) (accelerometers) assessed. Independent t-tests assessed sex differences. A regression (with MVPA as the outcome) was performed with all predictor variables (i.e. Actual Object Control, Actual Locomotor, Perceived Object Control, and Perceived Locomotor). Model 2 also adjusted for age, sex, accelerometer wear time and whether the child was from an English speaking background. Interaction terms between the respective actual or perceived skill factor and sex were added to assess sex differences. Analyses were conducted on 109 children (59 boys, 50 girls; mean age=6.5 years, SD=1.0). Boys had higher actual and perceived object control skill and were more active by an average of 19min per day. There were no sex differences in locomotor skills. There were no associations between skill factors and MVPA, except for girls, where locomotor skill was a significant predictor of MVPA (B=3.66, p=0.016). Actual rather than perceived skill competence was more important to MVPA in this sample. Locomotor skill competence may be more important than object control skill competence for girls as they may engage in types of physical activity that do not require object control mastery. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. The Field Relevance of NHTSA's Oblique Research Moving Deformable Barrier Tests.

    PubMed

    Prasad, Priya; Dalmotas, Dainius; German, Alan

    2014-11-01

    A small overlap frontal crash test has been recently introduced by the Insurance Institute for Highway Safety in its frontal rating scheme. Another small overlap frontal crash test is under development by the National Highway Traffic Safety Administration (NHTSA). Whereas the IIHS test is conducted against a fixed rigid barrier, the NHTSA test is conducted with a moving deformable barrier that overlaps 35% of the vehicle being tested and the angle between the longitudinal axis of the barrier and the longitudinal axis of the test vehicle is 15 degrees. The field relevance of the IIHS test has been the subject of a paper by Prasad et al. (2014). The current study is aimed at examining the field relevance of the NHTSA test. The field relevance is indicated by the frequency of occurrence of real world crashes that are simulated by the test conditions, the proportion of serious-to-fatal real world injuries explained by the test condition, and rates of serious injury to the head, chest and other body regions in the real world crashes resembling the test condition. The database examined for real world crashes is NASS. Results of the study indicate that 1.4% of all frontal 11-to-1 o'clock crashes are simulated by the test conditions that account for 2.4% to 4.5% of all frontal serious-to-fatal (MAIS3+F) injuries. Injury rates of the head and the chest are substantially lower in far-side than in near-side frontal impacts. Crash test ATD rotational responses of the head in the tests overpredict the real world risk of serious-to-fatal brain injuries.

  2. Onsite 40-kilowatt fuel cell power plant manufacturing and field test program

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A joint Gas Research Institute and U.S. Department of Energy Program was initiated in 1982 to evaluate the use of fuel cell power systems for on-site energy service. Forty-six 40 kW fuel cell power plants were manufactured at the United Technologies Corporation facility in South Windsor, Connecticut, and are being delivered to host utilities and other program participants in the United States and Japan for field testing. The construction of the 46 fully-integrated power plants was completed in January 1985 within the constraints of the contract plan. The program has provided significant experience in the manufacture, acceptance testing, deployment, and support of on-site fuel cell systems. Initial field test results also show that these experimental power plants meet the performance and environmental requirements of a commercial specification. This Interim Report encompasses the design and manufacturing phases of the 40 kW Power Plant Manufacturing and Field Test program. The contract between UTC and NASA also provides UTC field engineering support to the host utilities, training programs and associated manuals for utility operating and maintenance personnel, spare parts support for a defined test period, and testing at UTC of a power plant made available from a preceding program phase. These activities are ongoing and will be reported subsequently.

  3. Preliminary Results of Field Emission Cathode Tests

    NASA Technical Reports Server (NTRS)

    Sovey, James S.; Kovaleski, Scott D.

    2001-01-01

    Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

  4. An experimental evaluation of field sobriety tests in the marine environment

    DOT National Transportation Integrated Search

    1987-08-01

    This Report describes an investigation of the accuracy of Field Sobriety Tests (FSTs) : when used in the marine environment. FSPs are non-chemical tests of intoxication : which are used in highway law enforcement. These tests rely on the observation ...

  5. Are Human Mating Preferences with Respect to Height Reflected in Actual Pairings?

    PubMed Central

    Stulp, Gert; Buunk, Abraham P.; Pollet, Thomas V.; Nettle, Daniel; Verhulst, Simon

    2013-01-01

    Pair formation, acquiring a mate to form a reproductive unit, is a complex process. Mating preferences are a step in this process. However, due to constraining factors such as availability of mates, rival competition, and mutual mate choice, preferred characteristics may not be realised in the actual partner. People value height in their partner and we investigated to what extent preferences for height are realised in actual couples. We used data from the Millennium Cohort Study (UK) and compared the distribution of height difference in actual couples to simulations of random mating to test how established mate preferences map on to actual mating patterns. In line with mate preferences, we found evidence for: (i) assortative mating (r = .18), (ii) the male-taller norm, and, for the first time, (iii) for the male-not-too-tall norm. Couples where the male partner was shorter, or over 25 cm taller than the female partner, occurred at lower frequency in actual couples than expected by chance, but the magnitude of these effects was modest. We also investigated another preference rule, namely that short women (and tall men) prefer large height differences with their partner, whereas tall women (and short men) prefer small height differences. These patterns were also observed in our population, although the strengths of these associations were weaker than previously reported strength of preferences. We conclude that while preferences for partner height generally translate into actual pairing, they do so only modestly. PMID:23342102

  6. Are human mating preferences with respect to height reflected in actual pairings?

    PubMed

    Stulp, Gert; Buunk, Abraham P; Pollet, Thomas V; Nettle, Daniel; Verhulst, Simon

    2013-01-01

    Pair formation, acquiring a mate to form a reproductive unit, is a complex process. Mating preferences are a step in this process. However, due to constraining factors such as availability of mates, rival competition, and mutual mate choice, preferred characteristics may not be realised in the actual partner. People value height in their partner and we investigated to what extent preferences for height are realised in actual couples. We used data from the Millennium Cohort Study (UK) and compared the distribution of height difference in actual couples to simulations of random mating to test how established mate preferences map on to actual mating patterns. In line with mate preferences, we found evidence for: (i) assortative mating (r = .18), (ii) the male-taller norm, and, for the first time, (iii) for the male-not-too-tall norm. Couples where the male partner was shorter, or over 25 cm taller than the female partner, occurred at lower frequency in actual couples than expected by chance, but the magnitude of these effects was modest. We also investigated another preference rule, namely that short women (and tall men) prefer large height differences with their partner, whereas tall women (and short men) prefer small height differences. These patterns were also observed in our population, although the strengths of these associations were weaker than previously reported strength of preferences. We conclude that while preferences for partner height generally translate into actual pairing, they do so only modestly.

  7. Field Test of Route Planning Software for Lunar Polar Missions

    NASA Astrophysics Data System (ADS)

    Horchler, A. D.; Cunningham, C.; Jones, H. L.; Arnett, D.; Fang, E.; Amoroso, E.; Otten, N.; Kitchell, F.; Holst, I.; Rock, G.; Whittaker, W.

    2017-10-01

    A novel field test paradigm has been developed to demonstrate and validate route planning software in the stark low-angled light and sweeping shadows a rover would experience at the poles of the Moon. Software, ConOps, and test results are presented.

  8. A model for field toxicity tests

    USGS Publications Warehouse

    Kaiser, Mark S.; Finger, Susan E.

    1996-01-01

    Toxicity tests conducted under field conditions present an interesting challenge for statistical modelling. In contrast to laboratory tests, the concentrations of potential toxicants are not held constant over the test. In addition, the number and identity of toxicants that belong in a model as explanatory factors are not known and must be determined through a model selection process. We present one model to deal with these needs. This model takes the record of mortalities to form a multinomial distribution in which parameters are modelled as products of conditional daily survival probabilities. These conditional probabilities are in turn modelled as logistic functions of the explanatory factors. The model incorporates lagged values of the explanatory factors to deal with changes in the pattern of mortalities over time. The issue of model selection and assessment is approached through the use of generalized information criteria and power divergence goodness-of-fit tests. These model selection criteria are applied in a cross-validation scheme designed to assess the ability of a model to both fit data used in estimation and predict data deleted from the estimation data set. The example presented demonstrates the need for inclusion of lagged values of the explanatory factors and suggests that penalized likelihood criteria may not provide adequate protection against overparameterized models in model selection.

  9. Interaction between Stray Electrostatic Fields and a Charged Free-Falling Test Mass

    NASA Astrophysics Data System (ADS)

    Antonucci, F.; Cavalleri, A.; Dolesi, R.; Hueller, M.; Nicolodi, D.; Tu, H. B.; Vitale, S.; Weber, W. J.

    2012-05-01

    We present an experimental analysis of force noise caused by stray electrostatic fields acting on a charged test mass inside a conducting enclosure, a key problem for precise gravitational experiments. Measurement of the average field that couples to the test mass charge, and its fluctuations, is performed with two independent torsion pendulum techniques, including direct measurement of the forces caused by a change in electrostatic charge. We analyze the problem with an improved electrostatic model that, coupled with the experimental data, also indicates how to correctly measure and null the stray field that interacts with the test mass charge. Our measurements allow a conservative upper limit on acceleration noise, of 2(fm/s2)/Hz1/2 for frequencies above 0.1 mHz, for the interaction between stray fields and charge in the LISA gravitational wave mission.

  10. Interaction between stray electrostatic fields and a charged free-falling test mass.

    PubMed

    Antonucci, F; Cavalleri, A; Dolesi, R; Hueller, M; Nicolodi, D; Tu, H B; Vitale, S; Weber, W J

    2012-05-04

    We present an experimental analysis of force noise caused by stray electrostatic fields acting on a charged test mass inside a conducting enclosure, a key problem for precise gravitational experiments. Measurement of the average field that couples to the test mass charge, and its fluctuations, is performed with two independent torsion pendulum techniques, including direct measurement of the forces caused by a change in electrostatic charge. We analyze the problem with an improved electrostatic model that, coupled with the experimental data, also indicates how to correctly measure and null the stray field that interacts with the test mass charge. Our measurements allow a conservative upper limit on acceleration noise, of 2  (fm/s2)/Hz(1/2) for frequencies above 0.1 mHz, for the interaction between stray fields and charge in the LISA gravitational wave mission.

  11. Validation of the Puumala virus rapid field test for bank voles in Germany.

    PubMed

    Reil, D; Imholt, C; Rosenfeld, U M; Drewes, S; Fischer, S; Heuser, E; Petraityte-Burneikiene, R; Ulrich, R G; Jacob, J

    2017-02-01

    Puumala virus (PUUV) causes many human infections in large parts of Europe and can lead to mild to moderate disease. The bank vole (Myodes glareolus) is the only reservoir of PUUV in Central Europe. A commercial PUUV rapid field test for rodents was validated for bank-vole blood samples collected in two PUUV-endemic regions in Germany (North Rhine-Westphalia and Baden-Württemberg). A comparison of the results of the rapid field test and standard ELISAs indicated a test efficacy of 93-95%, largely independent of the origin of the antigens used in the ELISA. In ELISAs, reactivity for the German PUUV strain was higher compared to the Swedish strain but not compared to the Finnish strain, which was used for the rapid field test. In conclusion, the use of the rapid field test can facilitate short-term estimation of PUUV seroprevalence in bank-vole populations in Germany and can aid in assessing human PUUV infection risk.

  12. Field Test of Driven Pile Group under Lateral Loading

    NASA Astrophysics Data System (ADS)

    Gorska, Karolina; Rybak, Jaroslaw; Wyjadlowski, Marek

    2017-12-01

    All the geotechnical works need to be tested because the diversity of soil parameters is much higher than in other fields of construction. Horizontal load tests are necessary to determine the lateral capacity of driven piles subject to lateral load. Various load tests were carried out altogether on the test field in Kutno (Poland). While selecting the piles for load tests, different load combinations were taken into account. The piles with diverse length were chosen, on the basis of the previous tests of their length and integrity. The subsoil around the piles consisted of mineral soils: clays and medium compacted sands with the density index ID>0.50. The pile heads were free. The points of support of the “base” to which the dial gauges (displacement sensors) were fastened were located at the distance of 0.7 m from the side surface of the pile loaded laterally. In order to assure the independence of measurement, additional control (verifying) geodetic survey of the displacement of the piles subject to the load tests was carried out (by means of the alignment method). The trial load was imposed in stages by means of a hydraulic jack. The oil pressure in the actuator was corrected by means of a manual pump in order to ensure the constant value of the load in the on-going process of the displacement of the pile under test. On the basis of the obtained results it is possible to verify the numerical simulations of the behaviour of piles loaded by a lateral force.

  13. Field Test on the Feasibility of Remoting HF Antenna with Fiber Optics

    DTIC Science & Technology

    2008-07-31

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5652--08-9137 Field Test on the Feasibility of Remoting HF Antenna with Fiber Optics July...NUMBER (include area code) b. ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Field Test on the Feasibility of Remoting HF Antenna...optic link was employed to remote a high-frequency ( HF , 2-30 MHz) direction-finding (DF) array. The test link comprised a seven-element “L” array

  14. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less

  15. Emotionality in growing pigs: is the open field a valid test?

    PubMed

    Donald, Ramona D; Healy, Susan D; Lawrence, Alistair B; Rutherford, Kenneth M D

    2011-10-24

    The ability to assess emotionality is important within animal welfare research. Yet, for farm animals, few tests of emotionality have been well validated. Here we investigated the construct validity of behavioural measures of pig emotionality in an open-field test by manipulating the experiences of pigs in three ways. In Experiment One (pharmacological manipulation), pigs pre-treated with Azaperone, a drug used to reduce stress in commercial pigs, were more active, spent more time exploring and vocalised less than control pigs. In Experiment Two (social manipulation), pigs that experienced the open-field arena with a familiar companion were also more exploratory, spent less time behaviourally idle, and were less vocal than controls although to a lesser degree than in Experiment One. In Experiment Three (novelty manipulation), pigs experiencing the open field for a second time were less active, explored less and vocalised less than they had done in the first exposure to the arena. A principal component analysis was conducted on data from all three trials. The first two components could be interpreted as relating to the form (cautious to exploratory) and magnitude (low to high arousal) of the emotional response to open-field testing. Based on these dimensions, in Experiment One, Azaperone pigs appeared to be less fearful than saline-treated controls. However, in Experiment Two, exposure to the arena with a conspecific did not affect the first two dimensions but did affect a third behavioural dimension, relating to oro-nasal exploration of the arena floor. In Experiment Three, repeat exposure altered the form but not the magnitude of emotional response: pigs were less exploratory in the second test. In conclusion, behavioural measures taken from pigs in an open-field test are sensitive to manipulations of their prior experience in a manner that suggests they reflect underlying emotionality. Behavioural measures taken during open-field exposure can be useful for making

  16. A New Facility for Testing Superconducting Solenoid Magnets with Large Fringe Fields at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orris, D.; Carcagno, R.; Nogiec, J.

    2013-09-01

    Testing superconducting solenoid with no iron flux return can be problematic for a magnet test facility due to the large magnetic fringe fields generated. These large external fields can interfere with the operation of equipment while precautions must be taken for personnel supporting the test. The magnetic forces between the solenoid under test and the external infrastructure must also be taken under consideration. A new test facility has been designed and built at Fermilab specifically for testing superconducting magnets with large external fringe fields. This paper discusses the test stand design, capabilities, and details of the instrumentation and controls withmore » data from the first solenoid tested in this facility: the Muon Ionization Cooling Experiment (MICE) coupling coil.« less

  17. Field-testing a portable wind tunnel for fine dust emissions

    USDA-ARS?s Scientific Manuscript database

    A protable wind tunnel has been developed to allow erodibility and dust emissions testing of soil surfaces with the premise that dust concentration and properties are highly correlated with surface soil properties, as modified by crop management system. In this study we report on the field-testing ...

  18. On-site cell field test support program

    NASA Astrophysics Data System (ADS)

    Staniunas, J. W.; Merten, G. P.

    1982-09-01

    Utility sites for data monitoring were reviewed and selected. Each of these sites will be instrumented and its energy requirements monitored and analyzed for one year prior to the selection of 40 Kilowatt fuel cell field test sites. Analyses in support of the selection of sites for instrumentation shows that many building sectors offered considerable market potential. These sectors include nursing home, health club, restaurant, industrial, hotel/motel and apartment.

  19. Large Field Photogrammetry Techniques in Aircraft and Spacecraft Impact Testing

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.

    2010-01-01

    The Landing and Impact Research Facility (LandIR) at NASA Langley Research Center is a 240 ft. high A-frame structure which is used for full-scale crash testing of aircraft and rotorcraft vehicles. Because the LandIR provides a unique capability to introduce impact velocities in the forward and vertical directions, it is also serving as the facility for landing tests on full-scale and sub-scale Orion spacecraft mass simulators. Recently, a three-dimensional photogrammetry system was acquired to assist with the gathering of vehicle flight data before, throughout and after the impact. This data provides the basis for the post-test analysis and data reduction. Experimental setups for pendulum swing tests on vehicles having both forward and vertical velocities can extend to 50 x 50 x 50 foot cubes, while weather, vehicle geometry, and other constraints make each experimental setup unique to each test. This paper will discuss the specific calibration techniques for large fields of views, camera and lens selection, data processing, as well as best practice techniques learned from using the large field of view photogrammetry on a multitude of crash and landing test scenarios unique to the LandIR.

  20. InterGeo II: International Geographical Achievement Test. Field Trials Report and Test (Secondary Schools, Grade 8).

    ERIC Educational Resources Information Center

    Niemz, Gunter; Stoltman, Joseph P.

    InterGeo II, a project of the Commission on Geographical Education (CGE) of the International Geographical Union (IGU), has developed a broadly based, field-trialed testing instrument for making cross-national comparisons of achievement in geography. Field trials of InterGeo II were held in 23 countries. Data were analyzed for national achievement…

  1. Antioxidant effects of nerolidol in mice hippocampus after open field test.

    PubMed

    Nogueira Neto, José Damasceno; de Almeida, Antonia Amanda Cardoso; da Silva Oliveira, Johanssy; Dos Santos, Pauline Sousa; de Sousa, Damião Pergentino; de Freitas, Rivelilson Mendes

    2013-09-01

    The aim of this study was to evaluate the neuroprotective effects of nerolidol in mice hippocampus against oxidative stress in neuronal cells compared to ascorbic acid (positive control) as well as evaluated the nerolidol sedative effects by open field test compared to diazepam (positive control). Thirty minutes prior to behavioral observation on open field test, mice were intraperitoneally treated with vehicle, nerolidol (25, 50 and 75 mg/kg), diazepam (1 mg/kg) or ascorbic acid (250 mg/kg). To clarify the action mechanism of of nerolidol on oxidative stress in animals subjected to the open field test, Western blot analysis of Mn-superoxide dismutase and catalase in mice hippocampus were performed. In nerolidol group, there was a significant decrease in lipid peroxidation and nitrite levels when compared to negative control (vehicle). However, a significant increase was observed in superoxide dismutase and catalase activities in this group when compared to the other groups. Vehicle, diazepam, ascorbic acid and nerolidol groups did not affected Mn-superoxide dismutase, catalase mRNA or protein levels. Our findings strongly support the hypothesis that oxidative stress occurs in hippocampus. Nerolidol showed sedative effects in animals subjected to the open field test. Oxidative process plays a crucial role on neuronal pathological consequence, and implies that antioxidant effects could be achieved using this sesquiterpene.

  2. Evaluation of a Commercial Field Test to Detect African Swine Fever.

    PubMed

    Cappai, Stefano; Loi, Federica; Coccollone, Annamaria; Cocco, Manuele; Falconi, Caterina; Dettori, Giovanna; Feliziani, Francesco; Sanna, Maria Luisa; Oggiano, Annalisa; Rolesu, Sandro

    2017-07-01

    African swine fever (ASF) is one of the most important and complex infectious diseases affecting pigs ( Sus scrofa ). The disease has been present in Sardinia, Italy, since 1978. Factors influencing the presence of the disease on the island are the presence of illegally bred pigs, uncontrolled movements of animals, and local traditions. Implementation of public health programs is essential for controlling ASF. The use of new diagnostic techniques on both wild boar (WB) and illegally bred pigs would provide tools for faster and more inexpensive control of the disease. We evaluated a commercial serological test kit (Pen-side [PS]) for use in the field. We sampled 113 hunter-harvested WB during the 2014-15 season, collecting blood and lung samples to conduct serological analyses and to screen for the ASF virus. Although the sensitivity (81.8%) and specificity (95.9%) of tests performed in the field were reduced compared to the same test in laboratory, they nevertheless allowed for rapid diagnosis and reduced unnecessary carcass destruction. The test, conducted in the field, was less expensive than in the laboratory and required less manpower. Therefore, we conclude that the combined use of antibody PS test and antigen PS test may be a valuable emergency management method during an outbreak as well as a useful tool for conducting regular monitoring activities as a preventive policy.

  3. SERDP AND NRMRL SPONSOR FIELD TEST OF COSOLVENT-ENHANCED DNAPL REMOVAL

    EPA Science Inventory

    A field test of multicomponent cosolvent flooding for in-situ remediation of DNAPL source zones was conducted at the Dover National Test Site (DNTS) at Dover Air Force Base, Delaware, in July, 2001. The test was part of an Enhanced Source Removal (ESR) demonstration project fund...

  4. Beta Testing StraboSpot: Perspectives on mobile field mapping and data collection

    NASA Astrophysics Data System (ADS)

    Bunse, E.; Graham, K. A.; Rufledt, C.; Walker, J. D.; Müller, A.; Tikoff, B.

    2017-12-01

    Geologic field mapping has recently transitioned away from traditional techniques (e.g. field notebooks, paper mapping, Brunton compasses) and towards mobile `app' mapping technology. The StraboSpot system (Strabo) is an open-source solution for collection and storage for geologic field, microstructural, and lab-based data. Strabo's mission is to "enable recording and sharing data within the geoscience community, encourage interdisciplinary research, and facilitate the investigation of scientific questions that cannot currently be addressed" (Walker et al., 2015). Several mobile application beta tests of the system, on both Android and Apple iOS platforms using smartphones and tablets, began in Summer 2016. Students at the 2016 and 2017 University of Kansas Field Camps used Strabo in place of ArcGIS for Desktop on Panasonic Toughbooks, to field map two study areas. Strabo was also field tested by students of graduate and undergraduate level for both geo/thermochronologic sample collection and reconnaissance mapping associated with regional tectonic analysis in California. Throughout this period of testing, the app was geared toward structural and tectonic geologic data collection, but is versatile enough for other communities to currently use and is expanding to accommodate the sedimentology and petrology communities. Overall, users in each of the beta tests acclimated quickly to using Strabo for field data collection. Some key advantages to using Strabo over traditional mapping methods are: (1) Strabo allows for consolidation of materials in the field; (2) helps students track their position in the field with integrated GPS; and (3) Strabo data is in a uniform format making it simple for geologists to collaborate. While traditional field methods are not likely to go out of style in the near future, Strabo acts as a bridge between professional and novice geologists by providing a tool that is intuitive on all levels of geological and technological experience and

  5. Field Accuracy Test of Rpas Photogrammetry

    NASA Astrophysics Data System (ADS)

    Barry, P.; Coakley, R.

    2013-08-01

    Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV) photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS). We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This finding has shown

  6. Normal Threshold Size of Stimuli in Children Using a Game-Based Visual Field Test.

    PubMed

    Wang, Yanfang; Ali, Zaria; Subramani, Siddharth; Biswas, Susmito; Fenerty, Cecilia; Henson, David B; Aslam, Tariq

    2017-06-01

    The aim of this study was to demonstrate and explore the ability of novel game-based perimetry to establish normal visual field thresholds in children. One hundred and eighteen children (aged 8.0 ± 2.8 years old) with no history of visual field loss or significant medical history were recruited. Each child had one eye tested using a game-based visual field test 'Caspar's Castle' at four retinal locations 12.7° (N = 118) from fixation. Thresholds were established repeatedly using up/down staircase algorithms with stimuli of varying diameter (luminance 20 cd/m 2 , duration 200 ms, background luminance 10 cd/m 2 ). Relationships between threshold and age were determined along with measures of intra- and intersubject variability. The Game-based visual field test was able to establish threshold estimates in the full range of children tested. Threshold size reduced with increasing age in children. Intrasubject variability and intersubject variability were inversely related to age in children. Normal visual field thresholds were established for specific locations in children using a novel game-based visual field test. These could be used as a foundation for developing a game-based perimetry screening test for children.

  7. Analysis of Actual Soil Degradation by Erosion Using Satellite Imagery and Terrain Attributes in the Czech Republic

    NASA Astrophysics Data System (ADS)

    Zizala, Daniel

    2015-04-01

    Soil water and wind erosion (possibly tillage erosion) is the most significant soil degradation factor in the Czech Republic. Moreover, this phenomenon also affects seriously quality of water sources., About 50 % of arable land are endangered by water erosion and about 10 % of arable land are endangered wind erosion in the Czech Republic. These processes have been accelerated by human activity. Specific condition of agriculture land in the Czech Republic including highland relief and particularly size of land parcel and intensification of agriculture does not enable to reduce flow of runoff water. Insufficient protection against accelerated erosion processes is related to lack of landscape and hydrographic elements and large area of agricultural plots. Currently, this issue is solved at plot scale by field investigation or at regional scale using numerical and empirical erosion models. Nevertheless, these models enable only to predict the potential of soil erosion. Large scale assessment of actual degradation level of soils is based on expert knowledge. However, there are still many uncertainties in this issue. Therefore characterization of actual degradation level of soil is required especially for assessment of long-term impact of soil erosion on soil fertility. Soil degradation by erosion can be effectively monitored or quantified by modern tools of remote sensing with variable level of detail accessible. Aims of our study is to analyse the applicability of remote sensing for monitoring of actual soil degradation by erosion. Satellite and aerial image data (multispectral and hyperspectral), terrain attributes and data from field investigation are the main source for this analyses. The first step was the delimitation of bare soils using supervised classification of the set of Landsat scenes from 2000 - 2014. The most suitable period of time for obtaining spectral image data with the lowest vegetation cover of soil was determined. The results were verified by

  8. A PLAN FOR FIELD TESTING R/I UNITS.

    ERIC Educational Resources Information Center

    WARDROP, JAMES L.; AND OTHERS

    THIS PAPER DISCUSSES THE FIELD TESTING OF RESEARCH AND INSTRUCTION UNITS IN OPERATION IN A NUMBER OF WISCONSIN SCHOOLS. THE UNIT IS A REORGANIZED SCHOOL STRUCTURE WHICH IS MADE UP OF A LEARNING SPECIALIST LEADER, TEACHERS, PARAPROFESSIONALS, AND STUDENTS. THE MAJOR AIMS OF THIS EDUCATIONAL INNOVATION ARE (1) TO DEVELOP AND MAINTAIN AN…

  9. Ambassador Bridge Border Crossing System (ABBCS) : field operational test

    DOT National Transportation Integrated Search

    2000-05-01

    The purpose of the Ambassador Bridge Border Crossing System (ABBCS) field operational test (FOT) was to demonstrate the ability of ITS technology to expedite safe and legal international border crossings between Detroit, Michigan, and Windsor, Ontari...

  10. [Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work].

    PubMed

    Renner, Gerolf; Irblich, Dieter

    2016-11-01

    Test Reviews in Child Psychology: Test Users Wish to Obtain Practical Information Relevant to their Respective Field of Work This study investigated to what extent diagnosticians use reviews of psychometric tests for children and adolescents, how they evaluate their quality, and what they expect concerning content. Test users (n = 323) from different areas of work (notably social pediatrics, early intervention, special education, speech and language therapy) rated test reviews as one of the most important sources of information. Readers of test reviews value practically oriented descriptions and evaluations of tests that are relevant to their respective field of work. They expect independent reviews that critically discuss opportunities and limits of the tests under scrutiny. The results show that authors of test reviews should not only have a background in test theory but should also be familiar with the practical application of tests in various settings.

  11. Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras

    DTIC Science & Technology

    2017-10-01

    ARL-TR-8185 ● OCT 2017 US Army Research Laboratory Field Test Data for Detecting Vibrations of a Building Using High -Speed Video...Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras by Caitlin P Conn and Geoffrey H Goldman Sensors and...June 2016 – October 2017 4. TITLE AND SUBTITLE Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras 5a. CONTRACT

  12. Field test comparison of an autocorrelation technique for determining grain size using a digital 'beachball' camera versus traditional methods

    USGS Publications Warehouse

    Barnard, P.L.; Rubin, D.M.; Harney, J.; Mustain, N.

    2007-01-01

    This extensive field test of an autocorrelation technique for determining grain size from digital images was conducted using a digital bed-sediment camera, or 'beachball' camera. Using 205 sediment samples and >1200 images from a variety of beaches on the west coast of the US, grain size ranging from sand to granules was measured from field samples using both the autocorrelation technique developed by Rubin [Rubin, D.M., 2004. A simple autocorrelation algorithm for determining grain size from digital images of sediment. Journal of Sedimentary Research, 74(1): 160-165.] and traditional methods (i.e. settling tube analysis, sieving, and point counts). To test the accuracy of the digital-image grain size algorithm, we compared results with manual point counts of an extensive image data set in the Santa Barbara littoral cell. Grain sizes calculated using the autocorrelation algorithm were highly correlated with the point counts of the same images (r2 = 0.93; n = 79) and had an error of only 1%. Comparisons of calculated grain sizes and grain sizes measured from grab samples demonstrated that the autocorrelation technique works well on high-energy dissipative beaches with well-sorted sediment such as in the Pacific Northwest (r2 ??? 0.92; n = 115). On less dissipative, more poorly sorted beaches such as Ocean Beach in San Francisco, results were not as good (r2 ??? 0.70; n = 67; within 3% accuracy). Because the algorithm works well compared with point counts of the same image, the poorer correlation with grab samples must be a result of actual spatial and vertical variability of sediment in the field; closer agreement between grain size in the images and grain size of grab samples can be achieved by increasing the sampling volume of the images (taking more images, distributed over a volume comparable to that of a grab sample). In all field tests the autocorrelation method was able to predict the mean and median grain size with ???96% accuracy, which is more than

  13. Do Persistence and Passion Matter: Evidence from the Educational Testing Service Major Field Test in Business

    ERIC Educational Resources Information Center

    Ketcham, David; Nigro, Peter; Roberto, Michael

    2018-01-01

    The authors examined the determinants of success on the Educational Testing Service Major Field Test in Business. The authors find that gender, SAT performance, and concentration are significant predictors of performance. Additionally, they derive proxies for student passion and persistence, and find that the greater the student's passion for…

  14. Echoes from the Field: An Ethnographic Investigation of Outdoor Science Field Trips

    ERIC Educational Resources Information Center

    Boxerman, Jonathan Zvi

    2013-01-01

    As popular as field trips are, one might think they have been well-studied. Nonetheless, field trips have not been heavily studied, and little research has mapped what actually transpires during field trips. Accordingly, to address this research gap, I asked two related research questions. The first question is a descriptive one: What happens on…

  15. Field Testing Vocational Education Metric Modules. Final Report.

    ERIC Educational Resources Information Center

    Oldsen, Carl F.

    A project was conducted for the following purposes: (1) to develop a workshop training package to prepare vocational education teachers to use vocational subject-specific modules; (2) to train those teachers to use the workshop package; (3) to conduct field tests of the metric modules with experimental and control groups; (4) to analyze, describe,…

  16. Performance evaluation of infrared imaging system in field test

    NASA Astrophysics Data System (ADS)

    Wang, Chensheng; Guo, Xiaodong; Ren, Tingting; Zhang, Zhi-jie

    2014-11-01

    Infrared imaging system has been applied widely in both military and civilian fields. Since the infrared imager has various types and different parameters, for system manufacturers and customers, there is great demand for evaluating the performance of IR imaging systems with a standard tool or platform. Since the first generation IR imager was developed, the standard method to assess the performance has been the MRTD or related improved methods which are not perfect adaptable for current linear scanning imager or 2D staring imager based on FPA detector. For this problem, this paper describes an evaluation method based on the triangular orientation discrimination metric which is considered as the effective and emerging method to evaluate the synthesis performance of EO system. To realize the evaluation in field test, an experiment instrument is developed. And considering the importance of operational environment, the field test is carried in practical atmospheric environment. The test imagers include panoramic imaging system and staring imaging systems with different optics and detectors parameters (both cooled and uncooled). After showing the instrument and experiment setup, the experiment results are shown. The target range performance is analyzed and discussed. In data analysis part, the article gives the range prediction values obtained from TOD method, MRTD method and practical experiment, and shows the analysis and results discussion. The experimental results prove the effectiveness of this evaluation tool, and it can be taken as a platform to give the uniform performance prediction reference.

  17. Acadia National Park ITS field operational test : visitor survey

    DOT National Transportation Integrated Search

    2003-02-01

    In 2002, as part of the Acadia National Park Field Operational Test, Intelligent Transportation Systems (ITS) components were deployed to help visitors travel around Mount Desert Island and in Acadia National Park. Using data from surveys of visitors...

  18. Using biodynamic models to reconcile differences between laboratory toxicity tests and field biomonitoring with aquatic insects

    USGS Publications Warehouse

    Buchwalter, D.B.; Cain, D.J.; Clements, W.H.; Luoma, S.N.

    2007-01-01

    Aquatic insects often dominate lotic ecosystems, yet these organisms are under-represented in trace metal toxicity databases. Furthermore, toxicity data for aquatic insects do not appear to reflect their actual sensitivities to metals in nature, because the concentrations required to elicit toxicity in the laboratory are considerably higher than those found to impact insect communities in the field. New approaches are therefore needed to better understand how and why insects are differentially susceptible to metal exposures. Biodynamic modeling is a powerful tool for understanding interspecific differences in trace metal bioaccumulation. Because bioaccumulation alone does not necessarily correlate with toxicity, we combined biokinetic parameters associated with dissolved cadmium exposures with studies of the subcellular compartmentalization of accumulated Cd. This combination of physiological traits allowed us to make predictions of susceptibility differences to dissolved Cd in three aquatic insect taxa: Ephemerella excrucians, Rhithrogena morrisoni, and Rhyacophila sp. We compared these predictions with long-term field monitoring data and toxicity tests with closely related taxa: Ephemerella infrequens, Rhithrogena hageni, and Rhyacophila brunea. Kinetic parameters allowed us to estimate steady-state concentrations, the time required to reach steady state, and the concentrations of Cd projected to be in potentially toxic compartments for different species. Species-specific physiological traits identified using biodynamic models provided a means for better understanding why toxicity assays with insects have failed to provide meaningful estimates for metal concentrations that would be expected to be protective in nature. ?? 2007 American Chemical Society.

  19. Direct-to-consumer personalized genomic testing

    PubMed Central

    Bloss, Cinnamon S.; Darst, Burcu F.; Topol, Eric J.; Schork, Nicholas J.

    2011-01-01

    Over the past 18 months, there have been notable developments in the direct-to-consumer (DTC) genomic testing arena, in particular with regard to issues surrounding governmental regulation in the USA. While commentaries continue to proliferate on this topic, actual empirical research remains relatively scant. In terms of DTC genomic testing for disease susceptibility, most of the research has centered on uptake, perceptions and attitudes toward testing among health care professionals and consumers. Only a few available studies have examined actual behavioral response among consumers, and we are not aware of any studies that have examined response to DTC genetic testing for ancestry or for drug response. We propose that further research in this area is desperately needed, despite challenges in designing appropriate studies given the rapid pace at which the field is evolving. Ultimately, DTC genomic testing for common markers and conditions is only a precursor to the eventual cost-effectiveness and wide availability of whole genome sequencing of individuals, although it remains unclear whether DTC genomic information will still be attainable. Either way, however, current knowledge needs to be extended and enhanced with respect to the delivery, impact and use of increasingly accurate and comprehensive individualized genomic data. PMID:21828075

  20. ITC field test memorandum for Independence National Historical Park.

    DOT National Transportation Integrated Search

    2000-12-01

    This memorandum documents a field test conducted on October 26, 2000 in Philadelphia, PA for the proposed Independence Transportation Center (ITC). The ITC is a bus depot to support visitation to the National Constitution Center (NCC) and the Nationa...

  1. Pilot Field Test: Results of Tandem Walk Performance Following Long-Duration Spaceflight

    NASA Technical Reports Server (NTRS)

    Cerisano, J. M.; Reschke, M. F.; Kofman, I. S.; Fisher, E. A.; Gadd, N. E.; Phillips, T. R.; Lee, S. M. C.; Laurie, S. S.; Stenger, M. B.; Bloomberg, J. J.; hide

    2016-01-01

    Coordinated locomotion has proven to be challenging for many astronauts following long duration spaceflight. As NASA's vision for spaceflight points toward interplanetary travel and missions to distant objects, astronauts will not have assistance once they land. Thus, it is vital to develop a knowledge base from which operational guidelines can be written that define when astronauts can be expected to safely perform certain tasks. Data obtained during the Field Test experiment will add important insight to this knowledge base. Specifically, we aim to develop a recovery timeline of functional sensorimotor performance during the first 24 hours and several days after landing. A forerunner of the full Field Test study, the Pilot Field Test (PFT) comprised a subset of the tasks and measurements to be included in the ultimate set.

  2. Relationship between the Handball-Specific Complex-Test and Intermittent Field Test performance in professional players.

    PubMed

    Hermassi, Souhail; Hoffmeyer, Birgit; Irlenbusch, Lars; Fieseler, Georg; Noack, Frank; Delank, Karl-Stefan; Gabbett, Tim J; Souhaiel Chelly, Mohamed; Schwesig, René

    2018-01-01

    We investigated the relationship between the Handball Complex-Test (HBCT) and two selected field performance tests (the repeated sprint ability [RSA], and the Yo-Yo Intermittent Recovery Test) in elite handball players. Nineteen handball players (age: 25.7±5.1 years) were drawn from the First Professional German League. The HBCT consists of four activity series (AS): agility parcours, defensive action, sprint (10 m, 20 m) and throw-on-goal parcours; these activities were completed twice, with five active pauses of 30-35 s, and a follow-up of recovery over the subsequent 10 minutes. The RSA comprised 6 x (15+15 m) sprints starting every 20 s; scoring noted best time (RSAbest), total time (RSATT) and decrement (RSAdec). In the Yo-Yo Intermittent Recover, we recorded the total distance covered (TD). Heart rates (HR) were recorded throughout and recovery was assessed for measurements immediately post-test (R0) and 10 minutes after completing the test (R10). A strong correlation was found between HBCT and fastest 10 m and 20 m RSA sprint times (r=0.811, r=0.815, respectively). Also, the HBCT total 10 m and 20 m sprint times showed a strong positive association with RSATT (r=0.70; r=0.63, respectively), and the RSA heart rate post-test was strongly correlated with the HBCT heart rate after round two (r=0.865). Data from the match-specific HBCT Test shows a strong positive association with other more generic intermittent field test measurements. These observations support the validity of using the generic tests to monitor current fitness and responses to training in team handball players.

  3. A FIELD VALIDATION OF TWO SEDIMENT-AMPHIPOD TOXICITY TESTS

    EPA Science Inventory

    A field validation study of two sediment-amphipod toxicity tests was conducted using sediment samples collected subtidally in the vicinity of a polycyclic aromatic hydrocarbon (PAH)-contaminated Superfund site in Elliott Bay, WA, USA. Sediment samples were collected at 30 stati...

  4. Acadia National Park ITS field operational test : parking report

    DOT National Transportation Integrated Search

    2003-04-01

    An important goal of the Field Operational Test of ITS at Acadia National Park is to reduce vehicle congestion in the Park. Reduced congestion will have the added benefits of increased mobility of visitors and residents, aesthetic and environmental b...

  5. Testing the Wisconsin Phosphorus Index with year-round, field-scale runoff monitoring.

    PubMed

    Good, Laura W; Vadas, Peter; Panuska, John C; Bonilla, Carlos A; Jokela, William E

    2012-01-01

    The Wisconsin Phosphorus Index (WPI) is one of several P indices in the United States that use equations to describe actual P loss processes. Although for nutrient management planning the WPI is reported as a dimensionless whole number, it is calculated as average annual dissolved P (DP) and particulate P (PP) mass delivered per unit area. The WPI calculations use soil P concentration, applied manure and fertilizer P, and estimates of average annual erosion and average annual runoff. We compared WPI estimated P losses to annual P loads measured in surface runoff from 86 field-years on crop fields and pastures. As the erosion and runoff generated by the weather in the monitoring years varied substantially from the average annual estimates used in the WPI, the WPI and measured loads were not well correlated. However, when measured runoff and erosion were used in the WPI field loss calculations, the WPI accurately estimated annual total P loads with a Nash-Sutcliffe Model Efficiency (NSE) of 0.87. The DP loss estimates were not as close to measured values (NSE = 0.40) as the PP loss estimates (NSE = 0.89). Some errors in estimating DP losses may be unavoidable due to uncertainties in estimating on-farm manure P application rates. The WPI is sensitive to field management that affects its erosion and runoff estimates. Provided that the WPI methods for estimating average annual erosion and runoff are accurately reflecting the effects of management, the WPI is an accurate field-level assessment tool for managing runoff P losses. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  6. Flowpath evaluation and reconnaissance by remote field Eddy current testing (FERRET)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smoak, A.E.; Zollinger, W.T.

    1993-12-31

    This document describes the design and development of FERRET (Flowpath Evaluation and Reconnaisance by Remote-field Eddy current Testing). FERRET is a system for inspecting the steel pipes which carry cooling water to underground nuclear waste storage tanks. The FERRET system has been tested in a small scale cooling pipe mock-up, an improved full scale mock-up, and in flaw detection experiments. Early prototype designs of FERRET and the FERRET launcher (a device which inserts, moves, and retrieves probes from a piping system) as well as the field-ready design are discussed.

  7. Yes I can: Expected success promotes actual success in emotion regulation.

    PubMed

    Bigman, Yochanan E; Mauss, Iris B; Gross, James J; Tamir, Maya

    2016-11-01

    People who expect to be successful in regulating their emotions tend to experience less frequent negative emotions and are less likely to suffer from depression. It is not clear, however, whether beliefs about the likelihood of success in emotion regulation can shape actual emotion regulation success. To test this possibility, we manipulated participants' beliefs about the likelihood of success in emotion regulation and assessed their subsequent ability to regulate their emotions during a negative emotion induction. We found that participants who were led to expect emotion regulation to be more successful were subsequently more successful in regulating their emotional responses, compared to participants in the control condition. Our findings demonstrate that expected success can contribute to actual success in emotion regulation.

  8. Field evaluation of a malaria rapid diagnostic test (ICT Pf).

    PubMed

    Moonasar, Devanand; Goga, Ameena E; Kruger, Philip S; La Cock, Christine; Maharaj, Rajendra; Frean, John; Chandramohan, Daniel

    2009-11-01

    Malaria rapid diagnostic tests (MRDTs) are quick and easy to perform and useful for diagnosing malaria in primary health care settings. In South Africa most malaria infections are due to Plasmodium falciparurrm, and HRPII-based MRDTs have been used since 2001. Previous studies in Africa showed variability in sensitivity and specificity of HRPII-based MRDTs; hence, we conducted a field evaluation in Limpopo province to determine the accuracy of the MRDT currently used in public sector clinics and hospitals. A cross-sectional observational study was conducted to determine the sensitivity and specificity of an ICT Pf MRDT. We tested 405 patients with fever with ICT Pf MRDT and compared the results with blood film microscopy (the gold standard). RESULTS. The overall sensitivity of the ICT Pf MRDT was 99.48% (95% confidence interval (CI) 96.17-100%), while specificity was 96.26% (95% CI 94.7-100%). The positive predictive value of the test was 98.48 (99% CI 98.41-100%), and the negative predictive value was 99.52% (95% CI 96.47-100%). The ICT Pf MRDT is an appropriate test to use in the field in South Africa where laboratory facilities are not available. It has a high degree of sensitivity and acceptable level of specificity in accordance with the World Health Organization criteria. However, sensitivity of MRDT at low levels of parasitaemia (<100 parasites/microl of blood) in field conditions must still be established.

  9. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    DOT National Transportation Integrated Search

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  10. Operation of agricultural test fields for study of stressed crops by remote sensing

    NASA Technical Reports Server (NTRS)

    Toler, R. W.

    1974-01-01

    A test site for the study of winter wheat development and collection of ERTS data was established in September of 1973. The test site is a 10 mile square area located 12.5 miles west of Amarillo, Texas on Interstate Hwy. 40, in Randall and Potter counties. The center of the area is the Southwestern Great Plains Research Center at Bushland, Texas. Within the test area all wheat fields were identified by ground truth and designated irrigated or dryland. The fields in the test area other than wheat were identified as to pasture or the crop that was grown. A ground truth area of hard red winter wheat was established west of Hale Center, Texas. Maps showing the location of winter wheat fields in excess of 40 acres in size within a 10 mile radius were supplied NASA. Satellite data was collected for this test site (ERTS-1).

  11. Habituation of medaka (Oryzias latipes) demonstrated by open-field testing.

    PubMed

    Matsunaga, Wataru; Watanabe, Eiji

    2010-10-01

    Habituation to novel environments is frequently studied to analyze cognitive phenotypes in animals, and an open-field test is generally conducted to investigate the changes that occur in animals during habituation. The test has not been used in behavioral studies of medaka (Oryzias latipes), which is recently being used in behavioral research. Therefore, we examined the open-field behavior of medaka on the basis of temporal changes in 2 conventional indexes of locomotion and position. The findings of our study clearly showed that medaka changed its behavior through multiple temporal phases as it became more familiar with new surroundings; this finding is consistent with those of other ethological studies in animals. During repeated open-field testing on 2 consecutive days, we observed that horizontal locomotion on the second day was less than that on the first day, which suggested that habituation is retained in fish for days. This temporal habituation was critically affected by water factors or visual cues of the tank, thereby suggesting that fish have spatial memory of their surroundings. Thus, the data from this study will afford useful fundamental information for behavioral phenotyping of medaka and for elucidating cognitive phenotypes in animals. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  12. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    DOT National Transportation Integrated Search

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  13. Field tests prove microscale NRU to upgrade low-btu gas

    USGS Publications Warehouse

    Bhattacharya, Saibal; Newell, K. David; Watney, W. Lynn; Sigel, Micael

    2009-01-01

    The Kansas Geological Survey (University of Kansas) and the American Energies Corp., Wichita, have conducted field tests of a scalable, microscale, N2-rejection unit (NRU) to demonstrate its effectiveness to upgrade low-pressure ((<100 psig) and low-volume (=100 Mcfd) low-btu gas to pipeline quality. The tests aim to develop inexpensive NRU technology, which is designed for low- volume, low-pressure gas wells, to significantly increase the contribution of marginal low-btu gas to the gas supply of the US. The NRU uses two towers and uses three stages, namely, adsorption under pressure, venting to 2 psig, and desorption under vacuum. The modular design allows additional sets of towers to be added or removed to handle increases or decreases in feed volumes. The field tests also reveal that a strong compressor, which is capable of evacuating the tower (volume) as quickly as possible, should be employed to reduce process cycle time and increase plant throughput.

  14. Retesting The Validity Of A Specific Field Test For Judo Training

    PubMed Central

    Santos, Luis; González, Vicente; Iscar, Marta; Brime, Juan I.; Fernández-Río, Javier; Rodríguez, Blanca; Montoliu, Mª Ángeles

    2011-01-01

    The main goal of this research project was to retest the validity of a specifically designed judo field test (Santos Test) in a different group of judokas. Eight (n=8) national-level male judokas underwent laboratory and field testing. The mean data (mean +/− SD) obtained in the laboratory tests was: HRmax: 200 ± 4.0 beats × min−1, VO2 max: 52.8 ± 7.9 ± ml × kg−1 × min−1, lactate max: 12 ± 2.5 mmol × l−1, HR at the anaerobic threshold: 174.2 ± 9.4 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 87 ± 3.6 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 17.2 ± 1.0. The mean data obtained in the field test (Santos) was: HRmax: 201.3 ± 4.1 beats × min−1, VO2 max: 55.6 ± 5.8 ml × kg−1 × min−1, lactate max: 15.6 ± 2.8 mmol × l−1, HR at the anaerobic threshold: 173.2 ± 4.3 beats × min−1, percentage of maximum heart rate at which the anaerobic threshold appears: 86 ± 2.5 %, lactate threshold: 4.0 ± 0.2 mmol × l−1, and RPE: 16.7 ± 1.0. There were no significant differences between the data obtained on both tests in any of the parameters, except for maximum lactate concentration. Therefore, the Santos test can be considered a valid tool specific for judo training. PMID:23486994

  15. Smoldering Remediation of Coal-Tar-Contaminated Soil: Pilot Field Tests of STAR.

    PubMed

    Scholes, Grant C; Gerhard, Jason I; Grant, Gavin P; Major, David W; Vidumsky, John E; Switzer, Christine; Torero, Jose L

    2015-12-15

    Self-sustaining treatment for active remediation (STAR) is an emerging, smoldering-based technology for nonaqueous-phase liquid (NAPL) remediation. This work presents the first in situ field evaluation of STAR. Pilot field tests were performed at 3.0 m (shallow test) and 7.9 m (deep test) below ground surface within distinct lithological units contaminated with coal tar at a former industrial facility. Self-sustained smoldering (i.e., after the in-well ignition heater was terminated) was demonstrated below the water table for the first time. The outward propagation of a NAPL smoldering front was mapped, and the NAPL destruction rate was quantified in real time. A total of 3700 kg of coal tar over 12 days in the shallow test and 860 kg over 11 days in the deep test was destroyed; less than 2% of total mass removed was volatilized. Self-sustaining propagation was relatively uniform radially outward in the deep test, achieving a radius of influence of 3.7 m; strong permeability contrasts and installed barriers influenced the front propagation geometry in the shallow test. Reductions in soil hydrocarbon concentrations of 99.3% and 97.3% were achieved in the shallow and deep tests, respectively. Overall, this provides the first field evaluation of STAR and demonstrates that it is effective in situ and under a variety of conditions and provides the information necessary for designing the full-scale site treatment.

  16. Vadose zone transport field study: Detailed test plan for simulated leak tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AL Ward; GW Gee

    2000-06-23

    to: identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford's waste disposal sites; reduce uncertainty in conceptual models; develop a detailed and accurate database of hydraulic and transport parameters for validation of three-dimensional numerical models; identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. This plan provides details for conducting field tests during FY 2000 to accomplish these objectives. Details of additional testing during FY 2001 and FY 2002 will be developed as part of the work planning process implemented by the Integration Project.« less

  17. Cable testing for Fermilab's high field magnets using small racetrack coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feher, S.; Ambrosio, G.; Andreev, N.

    As part of the High Field Magnet program at Fermilab simple magnets have been designed utilizing small racetrack coils based on a sound mechanical structure and bladder technique developed by LBNL. Two of these magnets have been built in order to test Nb{sub 3}Sn cables used in cos-theta dipole models. The powder-in-tube strand based cable exhibited excellent performance. It reached its critical current limit within 14 quenches. Modified jelly roll strand based cable performance was limited by magnetic instabilities at low fields as previously tested dipole models which used similar cable.

  18. 40 CFR 1065.295 - PM inertial balance for field-testing analysis.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false PM inertial balance for field-testing analysis. 1065.295 Section 1065.295 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Pm Measurements § 1065.295 PM...

  19. 40 CFR 1065.295 - PM inertial balance for field-testing analysis.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false PM inertial balance for field-testing analysis. 1065.295 Section 1065.295 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Pm Measurements § 1065.295 PM...

  20. 40 CFR 1065.295 - PM inertial balance for field-testing analysis.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false PM inertial balance for field-testing analysis. 1065.295 Section 1065.295 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Pm Measurements § 1065.295 PM...

  1. Hypochondria as an actual neurosis.

    PubMed

    Nissen, Bernd

    2017-09-27

    Freud defined hypochondria as an actual neurosis. In this paper the actual neurosis will be interpreted as unbound traumatic elements which threaten the self. In severe hypochondria, breakdowns have occurred, as outlined by Winnicott. The nameless traumatic elements of the breakdown have been encapsulated. The moment these encapsulated elements are liberated, an actual dynamic takes place which threatens the self with annihilation. Projective identification is not possible because no idea of containment exists. The self tries to evacuate these elements projectively, thus triggering a disintegrative regression. However, the object of this projection, which becomes a malign introject, is felt to remove the remaining psychical elements, forcing the worthless residue back into the self. In a final re-introjection, the self is threatened by unintegration. To save the self, these elements are displaced into an organ which becomes hypochondriacal, an autistoid object, protecting itself against unintegration and decomposition. An autistoid dynamic develops between the hypochondriac organ, the ego and the introject. Two short clinical vignettes illustrate the regressive dynamical and metapsychological considerations. Copyright © 2017 Institute of Psychoanalysis.

  2. A Simple Soil Percolation Test Device for Field Environmentalists

    ERIC Educational Resources Information Center

    Smith, William H.; Stark, Phillip E.

    1977-01-01

    A primary responsibility of field environmental health workers is evaluation of individual sewage disposal system sites. The authors of this article developed a practical, accurate, and inexpensive measurement device for obtaining reliable percolation test results. Directions for the construction and use of the device are detailed. Drawings…

  3. First-time mothers' birth beliefs, preferences, and actual birth: A longitudinal observational study.

    PubMed

    Preis, Heidi; Eisner, Michal; Chen, Rony; Benyamini, Yael

    2018-05-09

    Birth preferences, such as mode and place of birth and other birth options, have important individual and societal implications, yet few studies have investigated the mechanism which predicts a wide range of childbirth options simultaneously. Basic beliefs about birth as a natural and as a medical process are both predictive factors for childbirth preferences. Studies investigating birth beliefs, preferences, and actual birth are rare. To test a predictive model of how these beliefs translate into birth preferences and into actual birth related-options. Longitudinal observational study including 342 first-time expectant mothers recruited at women's health centres and natural birth communities in Israel. All women filled out questionnaires including basic birth beliefs and preferred birth options. Two months postpartum, they filled out a questionnaire including detailed questions regarding actual birth. Stronger beliefs about birth being natural were related to preferring a more natural place and mode of birth and preferring more natural birth-related options. Stronger beliefs about birth being medical were associated with opposite options. The preferences mediated the association between the birth beliefs and actual birth. The beliefs predicted the preferences better than they predicted actual birth. Birth beliefs are pivotal in the decision-making process regarding preferred and actual birth options. In a medicalized obstetric system, where natural birth is something women need to actively seek out and insist on, the predictive powers of beliefs and of preferences decrease. Women's beliefs should be recognized and birth preferences respected. Copyright © 2018 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  4. Free Field Word recognition test in the presence of noise in normal hearing adults.

    PubMed

    Almeida, Gleide Viviani Maciel; Ribas, Angela; Calleros, Jorge

    In ideal listening situations, subjects with normal hearing can easily understand speech, as can many subjects who have a hearing loss. To present the validation of the Word Recognition Test in a Free Field in the Presence of Noise in normal-hearing adults. Sample consisted of 100 healthy adults over 18 years of age with normal hearing. After pure tone audiometry, a speech recognition test was applied in free field condition with monosyllables and disyllables, with standardized material in three listening situations: optimal listening condition (no noise), with a signal to noise ratio of 0dB and a signal to noise ratio of -10dB. For these tests, an environment in calibrated free field was arranged where speech was presented to the subject being tested from two speakers located at 45°, and noise from a third speaker, located at 180°. All participants had speech audiometry results in the free field between 88% and 100% in the three listening situations. Word Recognition Test in Free Field in the Presence of Noise proved to be easy to be organized and applied. The results of the test validation suggest that individuals with normal hearing should get between 88% and 100% of the stimuli correct. The test can be an important tool in measuring noise interference on the speech perception abilities. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Test operation of a real-time tsunami inundation forecast system using actual data observed by S-net

    NASA Astrophysics Data System (ADS)

    Suzuki, W.; Yamamoto, N.; Miyoshi, T.; Aoi, S.

    2017-12-01

    If the tsunami inundation information can be rapidly and stably forecast before the large tsunami attacks, the information would have effectively people realize the impeding danger and necessity of evacuation. Toward that goal, we have developed a prototype system to perform the real-time tsunami inundation forecast for Chiba prefecture, eastern Japan, using off-shore ocean bottom pressure data observed by the seafloor observation network for earthquakes and tsunamis along the Japan Trench (S-net) (Aoi et al., 2015, AGU). Because tsunami inundation simulation requires a large computation cost, we employ a database approach searching the pre-calculated tsunami scenarios that reasonably explain the observed S-net pressure data based on the multi-index method (Yamamoto et al., 2016, EPS). The scenario search is regularly repeated, not triggered by the occurrence of the tsunami event, and the forecast information is generated from the selected scenarios that meet the criterion. Test operation of the prototype system using the actual observation data started in April, 2017 and the performance and behavior of the system during non-tsunami event periods have been examined. It is found that the treatment of the noises affecting the observed data is the main issue to be solved toward the improvement of the system. Even if the observed pressure data are filtered to extract the tsunami signals, the noises in ordinary times or unusually large noises like high ocean waves due to storm affect the comparison between the observed and scenario data. Due to the noises, the tsunami scenarios are selected and the tsunami is forecast although any tsunami event does not actually occur. In most cases, the selected scenarios due to the noises have the fault models in the region along the Kurile or Izu-Bonin Trenches, far from the S-net region, or the fault models below the land. Based on the parallel operation of the forecast system with a different scenario search condition and

  6. Cross-cutting study of advanced rural transportation system ITS field operational tests

    DOT National Transportation Integrated Search

    1998-08-01

    USDOT has funded seven Advanced Rural Transportation System (ARTS) projects focused on traveler safety under the ITS Field Operational Test Program. Booz-Allen & Hamilton was contracted to oversee the evaluation of these (as well as 50+ other) field ...

  7. Medicinal Δ(9) -tetrahydrocannabinol (dronabinol) impairs on-the-road driving performance of occasional and heavy cannabis users but is not detected in Standard Field Sobriety Tests.

    PubMed

    Bosker, Wendy M; Kuypers, Kim P C; Theunissen, Eef L; Surinx, Anke; Blankespoor, Roos J; Skopp, Gisela; Jeffery, Wayne K; Walls, H Chip; van Leeuwen, Cees J; Ramaekers, Johannes G

    2012-10-01

    The acute and chronic effects of dronabinol [medicinal Δ(9) -tetrahydrocannabinol (THC)] on actual driving performance and the Standard Field Sobriety Test (SFST) were assessed. It was hypothesized that occasional users would be impaired on these tests and that heavy users would show less impairment due to tolerance. Double-blind, placebo-controlled, randomized, three-way cross-over study. Twelve occasional and 12 heavy cannabis users (14 males/10 females) received single doses of placebo, 10 and 20 mg dronabinol. Standard deviation of lateral position (SDLP; i.e. weaving) is the primary measure of road-tracking control. Time to speed adaptation (TSA) is the primary reaction-time measure in the car-following test. Percentage of impaired individuals on the SFST and subjective high on a visual analogue scale were secondary measures. Superiority tests showed that SDLP (P = 0.008) and TSA (P = 0.011) increased after dronabinol in occasional users. Equivalence tests demonstrated that dronabinol-induced increments in SDLP were bigger than impairment associated with BAC of 0.5 mg/ml in occasional and heavy users, although the magnitude of driving impairment was generally less in heavy users. The SFST did not discriminate between conditions. Levels of subjective high were comparable in occasional and heavy users. Dronabinol (medicinal tetrahydrocannabinol) impairs driving performance in occasional and heavy users in a dose-dependent way, but to a lesser degree in heavy users due possibly to tolerance. The Standard Field Sobriety Test is not sensitive to clinically relevant driving impairment caused by oral tetrahydrocannabinol. © 2012 The Authors. Addiction © 2012 Society for the Study of Addiction.

  8. Field Tests of a Portable MEMS Gravimeter

    PubMed Central

    Bramsiepe, Steven G.; Douglas, Rebecca; Hough, James; Hammond, Giles D.

    2017-01-01

    Gravimeters are used to measure density anomalies under the ground. They are applied in many different fields from volcanology to oil and gas exploration, but present commercial systems are costly and massive. A new type of gravity sensor has been developed that utilises the same fabrication methods as those used to make mobile phone accelerometers. In this study, we describe the first results of a field-portable microelectromechanical system (MEMS) gravimeter. The stability of the gravimeter is demonstrated through undertaking a multi-day measurement with a standard deviation of 5.58×10−6 ms−2. It is then demonstrated that a change in gravitational acceleration of 4.5×10−5 ms−2 can be measured as the device is moved between the top and the bottom of a 20.7 m lift shaft with a signal-to-noise ratio (SNR) of 14.25. Finally, the device is demonstrated to be stable in a more harsh environment: a 4.5×10−4 ms−2 gravity variation is measured between the top and bottom of a 275-m hill with an SNR of 15.88. These initial field-tests are an important step towards a chip-sized gravity sensor. PMID:29117099

  9. Field Tests of a Portable MEMS Gravimeter.

    PubMed

    Middlemiss, Richard P; Bramsiepe, Steven G; Douglas, Rebecca; Hough, James; Paul, Douglas J; Rowan, Sheila; Hammond, Giles D

    2017-11-08

    Gravimeters are used to measure density anomalies under the ground. They are applied in many different fields from volcanology to oil and gas exploration, but present commercial systems are costly and massive. A new type of gravity sensor has been developed that utilises the same fabrication methods as those used to make mobile phone accelerometers. In this study, we describe the first results of a field-portable microelectromechanical system (MEMS) gravimeter. The stability of the gravimeter is demonstrated through undertaking a multi-day measurement with a standard deviation of 5.58 × 10 - 6 ms - 2 . It is then demonstrated that a change in gravitational acceleration of 4.5 × 10 - 6 ms - 2 can be measured as the device is moved between the top and the bottom of a 20.7 m lift shaft with a signal-to-noise ratio (SNR) of 14.25. Finally, the device is demonstrated to be stable in a more harsh environment: a 4.5 × 10 - 4 ms - 2 gravity variation is measured between the top and bottom of a 275-m hill with an SNR of 15.88. These initial field-tests are an important step towards a chip-sized gravity sensor.

  10. Performance changes and relationship between vertical jump measures and actual sprint performance in elite sprinters with visual impairment throughout a Parapan American games training season

    PubMed Central

    Loturco, Irineu; Winckler, Ciro; Kobal, Ronaldo; Cal Abad, Cesar C.; Kitamura, Katia; Veríssimo, Amaury W.; Pereira, Lucas A.; Nakamura, Fábio Y.

    2015-01-01

    The aims of this study were to estimate the magnitude of variability and progression in actual competitive and field vertical jump test performances in elite Paralympic sprinters with visual impairment in the year leading up to the 2015 Parapan American Games, and to investigate the relationships between loaded and unloaded vertical jumping test results and actual competitive sprinting performance. Fifteen Brazilian Paralympic sprinters with visual impairment attended seven official competitions (four national, two international and the Parapan American Games 2015) between April 2014 and August 2015, in the 100- and 200-m dash. In addition, they were tested in five different periods using loaded (mean propulsive power [MPP] in jump squat [JS] exercise) and unloaded (squat jump [SJ] height) vertical jumps within the 3 weeks immediately prior to the main competitions. The smallest important effect on performances was calculated as half of the within-athlete race-to-race (or test-to-test) variability and a multiple regression analysis was performed to predict the 100- and 200-m dash performances using the vertical jump test results. Competitive performance was enhanced during the Parapan American Games in comparison to the previous competition averages, overcoming the smallest worthwhile enhancement in both the 100- (0.9%) and 200-m dash (1.43%). In addition, The SJ and JS explained 66% of the performance variance in the competitive results. This study showed that vertical jump tests, in loaded and unloaded conditions, could be good predictors of the athletes' sprinting performance, and that during the Parapan American Games the Brazilian team reached its peak competitive performance. PMID:26594181

  11. Associations between young children's perceived and actual ball skill competence and physical activity.

    PubMed

    Barnett, Lisa M; Ridgers, Nicola D; Salmon, Jo

    2015-03-01

    The relationship between actual and perceived object control competence (ball skills) and the contribution to young children's physical activity is not known. Cross sectional study. The Test Gross Motor Development-2 assessed actual object control competence and a modified version of the Pictorial Scale of Perceived Competence and Social Acceptance for Young Children assessed perceived object control competence. Moderate- to vigorous-intensity physical activity was measured via accelerometry. Three mixed regression models were performed: (i) object control competence as the predictor and the outcome as perceived object control, (ii) perceived object control competence as the predictor and the outcome moderate to vigorous physical activity and (iii) actual object control as the predictor and the outcome moderate to vigorous physical activity. Models adjusted for school clustering, monitor wear time, sex and age. Interactions between respective predictor variables and sex were performed if warranted. A total of 102 children (56% boys, 44% girls) aged 4-8 years (M 6.3, SD 0.92) completed assessments. Girls had lower perceived and actual object control competence and were less active than boys. Actual object control competence was positively associated with perceived object control competence (B=0.11, t(96)=2.25, p<0.001, p=0.027) and this relationship did not differ by sex (p=0.449); however, neither actual (p=0.092) nor perceived object control competence (p=0.827) were associated with moderate to vigorous physical activity. Young children's perceived ball skill abilities appear to relate to actual competence; however, these measures were not associated with physical activity. In older children, object control skill is associated with physical activity so targeting young children's object control skills is an intervention priority. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  12. Actual change and inaccurate recall contribute to posttraumatic growth following radiotherapy.

    PubMed

    Ransom, Sean; Sheldon, Kennon M; Jacobsen, Paul B

    2008-10-01

    People with cancer often report that they experience personal growth as a result of the disease, but such reports have unclear validity. Some suggest such growth results from Rogers's (1951) hypothesized organismic valuing process (OVP), an innate tendency for people to gravitate toward well-being; others suggest this growth may be a positive illusion resulting from temporal self-comparisons. To test these conceptualizations, the authors examined 83 individuals with Stages 0-III breast or prostate cancer. Patients completed measures of positive attributes and personal life goals before radiotherapy (Time 1) and after radiotherapy (Time 2). At Time 2, participants also attempted to recreate their Time 1 responses and completed a posttraumatic growth (PTG) measure. PTG was significantly related with actual increases (but not perceived increases) in the relative importance of intrinsic goals versus extrinsic goals and with perceived increases (but not actual increases) in positive attributes. These measures were unrelated to one another and thus explained unique variance in PTG. Data suggest that both actual change processes related to the OVP and biases in autobiographic recall may independently contribute to PTG reports. (c) 2008 APA, all rights reserved.

  13. Associations between skill perceptions and young children's actual fundamental movement skills.

    PubMed

    Liong, Grace H E; Ridgers, Nicola D; Barnett, Lisa M

    2015-04-01

    Given that children with low movement skill competence engage in less physical activity, it is important to understand how children's perceptions relate to actual movement competence. This study examined relationships between (i) children's self-perception and objective assessments of their movement skills (object control and locomotor) and (ii) parents' perceptions of the children's movement skills and objective assessment. Children's skill perceptions were assessed using the Pictorial Scale of Perceived Movement Skill Competence for Young Children. Parent perceptions of their child's skills were assessed using a modified version of this instrument. The Test of Gross Motor Development-2nd edition assessed children's skills objectively. Participants were 136 Australian children (51% boys; M=6.5 yr., SD=1.1) and 133 parents. Regression analyses (by sex) examined the relationship between perceptions and children's scores for actual skilled performance. Boys' perceptions were associated with their actual object control ability. Parents accurately perceived boys' object control ability and girls' locomotor ability, but not the reverse. This suggests interventions aiming to improve children's movement skills could target parents and be designed to teach parents how to recognize good and poor skill performance in their children.

  14. Characterization of instrumented sites for the onsite fuel-cell field-test project. Volume 4. Topical report, 1983-1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Racine, W.C.; Campillo, C.J.

    During the site-selection phase of the Onsite Fuel-Cell Field Test, nearly one hundred sites throughout the U.S. were each instrumented with a standard data-acquisition system (DAS) to collect hourly electrical and thermal data for one year. Seventy of those sites are included in the report. Each site's electrical and thermal systems were instrumented including ambient temperature, electrical demands, building gas usage, and other parameters necessary to calculate building thermal loads. Multifamily residential, commercial, and light industrial sites were instrumented. Approximately twenty market sectors were represented including restaurants, hospitals, hotels, apartments, health clubs, nursing homes, and food-processing plants. The primary usemore » of the data was to determine site compatibility for the installation of 40-kW fuel-cell power plants. However, the collected energy data and site-specific information summarized in this comprehensive report may also be useful for other applications such as market characterization and simulation of new or improved energy-utilization equipment in actual sites. This volume covers metal-plating facilities, nurseries, nursing homes, office buildings and other industrial applications.« less

  15. Early detection of glaucoma by means of a novel 3D computer‐automated visual field test

    PubMed Central

    Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald

    2007-01-01

    Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of

  16. Field testing existence values for riparian ecosystems

    Treesearch

    John W. Duffield; Chris J. Neher; David A. Patterson; Patricia A. Champ

    2007-01-01

    This paper presents preliminary findings on a cash and contingent valuation (cv) experiment. The study replicates major elements of an earlier (1990) experiment, which solicited hypothetical and actual donations to benefit instream flows for Montana fisheries. Extensions of the earlier work include: repeat contacts to increase response rate, follow-up of the contingent...

  17. Field Test of Wake Steering at an Offshore Wind Farm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, Paul; Annoni, Jennifer; Shah, Jigar J.

    In this paper, a field test of wake steering control is presented. The field test is the result of a collaboration between the National Renewable Energy Laboratory (NREL) and Envision Energy, a smart energy management company and turbine manufacturer. In the campaign, an array of turbines within an operating commercial offshore wind farm in China have the normal yaw controller modified to implement wake steering according to a yaw control strategy. The strategy was designed using NREL wind farm models, including a computational fluid dynamics model, SOWFA, for understanding wake dynamics and an engineering model, FLORIS, for yaw control optimization.more » Results indicate that, within the certainty afforded by the data, the wake-steering controller was successful in increasing power capture, by amounts similar to those predicted from the models.« less

  18. Field Test of Wake Steering at an Offshore Wind Farm

    DOE PAGES

    Fleming, Paul; Annoni, Jennifer; Shah, Jigar J.; ...

    2017-02-06

    In this paper, a field test of wake steering control is presented. The field test is the result of a collaboration between the National Renewable Energy Laboratory (NREL) and Envision Energy, a smart energy management company and turbine manufacturer. In the campaign, an array of turbines within an operating commercial offshore wind farm in China have the normal yaw controller modified to implement wake steering according to a yaw control strategy. The strategy was designed using NREL wind farm models, including a computational fluid dynamics model, SOWFA, for understanding wake dynamics and an engineering model, FLORIS, for yaw control optimization.more » Results indicate that, within the certainty afforded by the data, the wake-steering controller was successful in increasing power capture, by amounts similar to those predicted from the models.« less

  19. Results from Field Testing the RIMFAX GPR on Svalbard.

    NASA Astrophysics Data System (ADS)

    Hamran, S. E.; Amundsen, H. E. F.; Berger, T.; Carter, L. M.; Dypvik, H.; Ghent, R. R.; Kohler, J.; Mellon, M. T.; Nunes, D. C.; Paige, D. A.; Plettemeier, D.; Russell, P.

    2017-12-01

    The Radar Imager for Mars' Subsurface Experiment - RIMFAX is a Ground Penetrating Radar being developed for NASÁs MARS 2020 rover mission. The principal goals of the RIMFAX investigation are to image subsurface structures, provide context for sample sites, derive information regarding subsurface composition, and search for ice or brines. In meeting these goals, RIMFAX will provide a view of the stratigraphic section and a window into the geological and environmental history of Mars. To verify the design an Engineering Model (EM) of the radar was tested in the field in the spring 2017. Different sounding modes on the EM were tested in different types of subsurface geology on Svalbard. Deep soundings were performed on polythermal glaciers down to a couple of hundred meters. Shallow soundings were used to map a ground water table in the firn area of a glacier. A combination of deep and shallow soundings was used to image buried ice under a sedimentary layer of a couple of meters. Subsurface sedimentary layers were imaged down to more than 20 meters in sand stone permafrost. This presentation will give an overview of the RIMFAX investigation, describe the development of the radar system, and show results from field tests of the radar.

  20. Active tower damping and pitch balancing - design, simulation and field test

    NASA Astrophysics Data System (ADS)

    Duckwitz, Daniel; Shan, Martin

    2014-12-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.

  1. Developing Mathematical Processes (DMP). Field Test Evaluation, 1973-1974.

    ERIC Educational Resources Information Center

    Schall, William; And Others

    The Developing Mathematical Processes (DMP) program was field-tested in the kindergarten and first three grades of one parochial and five public schools. DMP is an activity-based program developed around a comprehensive list of behavioral objectives. The program is concerned with the development of intuitive geometric concepts as well as…

  2. Developing Mathematical Processes (DMP). Field Test Evaluation, 1972-1973.

    ERIC Educational Resources Information Center

    Schall, William E.; And Others

    The field test of the Developing Mathematical Processes (DMP) program was conducted jointly by the Falconer Central School, St. Mary's Elementary School in Dunkirk, New York, and the Teacher Education Research Center at the State University College in Fredonia, New York. DMP is a research-based, innovative, process-oriented elementary mathematics…

  3. SMART operational field test evaluation : dispatchers survey report : final report

    DOT National Transportation Integrated Search

    1997-06-01

    The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automaticscheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans toimplement ITS as a site for an operational field test. The purpo...

  4. Multibar sawless lint cleaner: fiber quality analysis after 3rd year of field testing

    USDA-ARS?s Scientific Manuscript database

    After two years of field testing a prototype spiked-tooth lint cleaner, the Multibar Sawless Lint Cleaner (MBSLC), a final year of field evaluation was conducted at commercial cotton gin in West Texas located approximately 30 miles Southwest of Lubbock, Texas.The cotton lint cleaner was tested in a ...

  5. What State Tests Test.

    ERIC Educational Resources Information Center

    McGee, Glenn W.

    What the Illinois Goal Assessment Program (IGAP) test actually tests and the consequences of these tests for funding decisions were studied with a random sample of 100 school districts in the Cook County suburbs of Chicago. Eighth-grade IGAP scores for reading were obtained from the state report card, a document prepared by each school district…

  6. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    NASA Astrophysics Data System (ADS)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  7. Creating a testing field where delta technology and water innovations are tested and demonstrated with the help of citizen science methods

    NASA Astrophysics Data System (ADS)

    de Vries, Sandra; Rutten, Martine; de Vries, Liselotte; Anema, Kim; Klop, Tanja; Kaspersma, Judith

    2017-04-01

    In highly populated deltas, much work is to be done. Complex problems ask for new and knowledge driven solutions. Innovations in delta technology and water can bring relief to managing the water rich urban areas. Testing fields form a fundamental part of the knowledge valorisation for such innovations. In such testing fields, product development by start-ups is coupled with researchers, thus supplying new scientific insights. With the help of tests, demonstrations and large-scale applications by the end-users, these innovations find their way to the daily practices of delta management. More and more cities embrace the concept of Smart Cities to tackle the ongoing complexity of urban problems and to manage the city's assets - such as its water supply networks and other water management infrastructure. Through the use of new technologies and innovative systems, data are collected from and with citizens and devices - then processed and analysed. The information and knowledge gathered are keys to enabling a better quality of life. By testing water innovations together with citizens in order to find solutions for water management problems, not only highly spatial amounts of data are provided by and/or about these innovations, they are also improved and demonstrated to the public. A consortium consisting of a water authority, a science centre, a valorisation program and two universities have joined forces to create a testing field for delta technology and water innovations using citizen science methods. In this testing field, the use of citizen science for water technologies is researched and validated by facilitating pilot projects. In these projects, researchers, start-ups and citizens work together to find the answer to present-day water management problems. The above mentioned testing field tests the use of crowd-sourcing data as for example hydrological model inputs, or to validate remote sensing applications, or improve water management decisions. Currently the

  8. Pressure and temperature fields associated with aero-optics tests. [transonic wind tunnel tests

    NASA Technical Reports Server (NTRS)

    Raman, K. R.

    1980-01-01

    The experimental investigation carried out in a 6 x 6 ft wind tunnel on four model configurations in the aero-optics series of tests are described. The data obtained on the random pressures (static and total pressures) and total temperatures are presented. In addition, the data for static pressure fluctuations on the Coelostat turret model are presented. The measurements indicate that the random pressures and temperature are negligible compared to their own mean (or steady state) values for the four models considered, thus allowing considerable simplification in the calculations to obtain the statistical properties of the density field. In the case of the Coelostat model tests these simplifications cannot be assumed a priori and require further investigation.

  9. Guidelines on Pilot and Field Testing of Curriculum Products.

    ERIC Educational Resources Information Center

    Contract Research Corp., Belmont, MA.

    This booklet is intended to aid curriculum developers in designing and conducting pilot or field tests that yield useful information and sound evidence about the effectiveness of new curricula. Although it was prepared specifically for use by projects funded by the Curriculum Development Branch of the federal Bureau of Occupational and Adult…

  10. Experimental field test of proposed pedestrian safety messages. Volume 3

    DOT National Transportation Integrated Search

    1983-11-01

    Author's abstract: A detailed re-analysis of available pedestrian accident data was utilized to define three sets of pedestrian safety public information and education (PI&E) Messages. These messages were then produced and field tested. The objective...

  11. Vibrational multiconfiguration self-consistent field theory: implementation and test calculations.

    PubMed

    Heislbetz, Sandra; Rauhut, Guntram

    2010-03-28

    A state-specific vibrational multiconfiguration self-consistent field (VMCSCF) approach based on a multimode expansion of the potential energy surface is presented for the accurate calculation of anharmonic vibrational spectra. As a special case of this general approach vibrational complete active space self-consistent field calculations will be discussed. The latter method shows better convergence than the general VMCSCF approach and must be considered the preferred choice within the multiconfigurational framework. Benchmark calculations are provided for a small set of test molecules.

  12. Comparisons of Field Tests with Simulations: Abrams Program Lessons Learned

    DTIC Science & Technology

    1990-03-01

    observed field out conme. Thiirtv-.-ixI\\ (3(-) of thle com parisons resulted in complete iuj .muatchves: thatif -. S ~u,-VSII inever )in its J000...2.REPORT DAE j3 EOTTP ~ AE OEE IMairch 1990 I-Final Jul 87 - Oct 89 4. TitE AND SUBTMTE S . PUNOING NUMBWERS (Comparisons or Field Tests with...Simulations: Abrams Program Lessons Learned 6. AUTHOR( S ) lPaul 11. lDcvtz, Jill I[. Smith. John 11. Stickling 7. PERFORMING ORGANIZATION NAME( S ) AND AIDDRESS

  13. Synchrotron Intensity Gradients as Tracers of Interstellar Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Lazarian, A.; Yuen, Ka Ho; Lee, Hyeseung; Cho, J.

    2017-06-01

    On the basis of the modern understanding of MHD turbulence, we propose a new way of using synchrotron radiation: using synchrotron intensity gradients (SIGs) for tracing astrophysical magnetic fields. We successfully test the new technique using synthetic data obtained with 3D MHD simulations and provide the demonstration of the practical utility of the technique by comparing the directions of magnetic fields that are obtained with PLANCK synchrotron intensity data to the directions obtained with PLANCK synchrotron polarization data. We demonstrate that the SIGs can reliably trace magnetic fields in the presence of noise and can provide detailed maps of magnetic field directions. We also show that the SIGs are relatively robust for tracing magnetic fields while the low spatial frequencies of the synchrotron image are removed. This makes the SIGs applicable to the tracing of magnetic fields using interferometric data with single-dish measurement absent. We discuss the synergy of using the SIGs together with synchrotron polarization in order to find the actual direction of the magnetic fields and quantify the effects of Faraday rotation as well as with other ways of studying astrophysical magnetic fields. We test our method in the presence of noise and the resolution effects. We stress the complementary nature of the studies using the SIG technique and those employing the recently introduced velocity gradient techniques that trace magnetic fields using spectroscopic data.

  14. SMART operational field test evaluation : scheduler survey report : final report

    DOT National Transportation Integrated Search

    1997-06-01

    The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automatic scheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans to implement ITS as a site for an operational field test. The pur...

  15. Minimal detectable change of the actual amount of use test and the motor activity log: the EXCITE Trial.

    PubMed

    Chen, Shuya; Wolf, Steven L; Zhang, Qin; Thompson, Paul A; Winstein, Carolee J

    2012-06-01

    Efficacy of task-oriented training can be reliably trusted only when the inherent measurement variability is determined. The Actual Amount of Use Test (AAUT) and the Motor Activity Log (MAL) have been used together as measures of spontaneous arm use after an intervention; however, the minimal detectable change (MDC) of AAUT and MAL has not been addressed. To compare the MDC₉₀ of the AAUT and the MAL in the context of a randomized controlled trial of a neurorehabilitation intervention, the Extremity Constraint-Induced Therapy Evaluation trial. A preplanned secondary analysis was conducted using pre-post test data from the control group. Estimated MDC₉₀ were normalized to the maximum value of the scale of the AAUT and the MAL for each subscale: amount of use (AAUTa, MALa) and quality of movement (AAUTq, MALq). . The MDC₉₀ of the AAUTq and the MALq were 14.4% and 15.4%, respectively. However, the MDC₉₀ required greater change for the AAUTa (24.2%) than the MALa (16.8%). The training-induced spontaneous arm use exceeded the MDC₉₀ for the MAL but fell below that for the AAUT immediately after the intervention and at 1-year follow-up visit. The greater variability and insensitivity to treatment effect for the AAUTa is likely because of the low resolution of its scoring system. As such, there is a considerable need to develop valid and reliable tools that capture purposeful arm use outside the laboratory, perhaps through leveraging new sensing technologies with objective activity monitoring.

  16. Minimal Detectable Change of the Actual Amount of Use Test and the Motor Activity Log: The EXCITE Trial

    PubMed Central

    Chen, Shuya; Wolf, Steven L.; Zhang, Qin; Thompson, Paul A.; Winstein, Carolee J.

    2013-01-01

    Background Efficacy of task-oriented training can be reliably trusted only when the inherent measurement variability is determined. The Actual Amount of Use Test (AAUT) and the Motor Activity Log (MAL) have been used together as measures of spontaneous arm use after an intervention; however, the minimal detectable change (MDC) of AAUT and MAL has not been addressed. Objective To compare the MDC90 of the AAUT and the MAL in the context of a randomized controlled trial of a neurorehabilitation intervention, the Extremity Constraint-Induced Therapy Evaluation trial. Methods A preplanned secondary analysis was conducted using pre–post test data from the control group. Estimated MDC90 were normalized to the maximum value of the scale of the AAUT and the MAL for each subscale: amount of use (AAUTa, MALa) and quality of movement (AAUTq, MALq). Results The MDC90 of the AAUTq and the MALq were 14.4% and 15.4%, respectively. However, the MDC90 required greater change for the AAUTa (24.2%) than the MALa (16.8%). The training-induced spontaneous arm use exceeded the MDC90 for the MAL but fell below that for the AAUT immediately after the intervention and at 1-year follow-up visit. Conclusions The greater variability and insensitivity to treatment effect for the AAUTa is likely because of the low resolution of its scoring system. As such, there is a considerable need to develop valid and reliable tools that capture purposeful arm use outside the laboratory, perhaps through leveraging new sensing technologies with objective activity monitoring. PMID:22275157

  17. Intelligent cruise control field operational test. Volume I, Technical report

    DOT National Transportation Integrated Search

    1998-05-01

    This document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The main goal of the work is to characterize safety and comfort issues that are fundamental to human inte...

  18. Comprehensive visual field test & diagnosis system in support of astronaut health and performance

    NASA Astrophysics Data System (ADS)

    Fink, Wolfgang; Clark, Jonathan B.; Reisman, Garrett E.; Tarbell, Mark A.

    Long duration spaceflight, permanent human presence on the Moon, and future human missions to Mars will require autonomous medical care to address both expected and unexpected risks. An integrated non-invasive visual field test & diagnosis system is presented for the identification, characterization, and automated classification of visual field defects caused by the spaceflight environment. This system will support the onboard medical provider and astronauts on space missions with an innovative, non-invasive, accurate, sensitive, and fast visual field test. It includes a database for examination data, and a software package for automated visual field analysis and diagnosis. The system will be used to detect and diagnose conditions affecting the visual field, while in space and on Earth, permitting the timely application of therapeutic countermeasures before astronaut health or performance are impaired. State-of-the-art perimetry devices are bulky, thereby precluding application in a spaceflight setting. In contrast, the visual field test & diagnosis system requires only a touchscreen-equipped computer or touchpad device, which may already be in use for other purposes (i.e., no additional payload), and custom software. The system has application in routine astronaut assessment (Clinical Status Exam), pre-, in-, and post-flight monitoring, and astronaut selection. It is deployable in operational space environments, such as aboard the International Space Station or during future missions to or permanent presence on the Moon and Mars.

  19. Ten years later: Evaluation of the effectiveness of 12.5% amitraz against a field population of Rhipicephalus (Boophilus) microplus using field studies, artificial infestation (Stall tests) and adult immersion tests.

    PubMed

    Maciel, Willian Giquelin; Lopes, Welber Daniel Zanetti; Cruz, Breno Cayeiro; Gomes, Lucas Vinicius Costa; Teixeira, Weslen Fabrício Pires; Buzzulini, Carolina; Bichuette, Murilo Abud; Campos, Gabriel Pimentel; Felippelli, Gustavo; Soares, Vando Edésio; de Oliveira, Gilson Pereira; da Costa, Alvimar José

    2015-12-15

    Using field trials, artificial infestations (Stall tests) and in vitro adult immersion tests, the present study evaluated the acaricidal efficacy of 12.5% amitraz administered via whole body spraying against a Rhipicephalus (Boophilus) microplus population that did not have any contact with chemical products belonging to this acaricide family for 10 years (approximately 40 generations). Two natural infestation trials, two artificial infestation trials (Stall tests) and two adult immersion tests were performed in two different stages in 2005 and 2015. Between 2002 and 2015, the bovine herd of this property was formed by approximately 450 animals from the Simmental breed that were divided into nine paddocks formed by Cynodon dactylon (L.) Pers. For the natural infestation experiments in 2005 and 2015, we selected nearly 70 animals naturally infested with ticks from the same herd that belonged to the "São Paulo" farm located in São José do Rio Pardo, São Paulo, Brazil. Field studies were performed in the same paddock (9). To evaluate anti-R. (B.) microplus activity in the artificially infested cattle (Stall tests) and adult immersion tests, two experiments of each methodology were performed at CPPAR (the Center of Research in Animal Health located on the FCAV/UNESP campus in Jaboticabal, São Paulo, Brazil) in 2005 and 2015. R. (B.) microplus used in the artificial infestation, and adult immersion test experiments were obtained from paddocks 1-9 in 2005 and 2015 from the commercial farm where the field studies were performed. Based on the obtained results, it was possible to conclude that amitraz use in rotation with pyrethroids every 28 days for three consecutive years (2002-2004) previous to the beginning of the first trial (2005) was sufficient to generate a R. (B.) microplus strain resistant to amitraz. Moreover, using field trials, artificial infestations (Stall tests) and adult immersion tests, we verified that 40 generations of the tick species with no

  20. Has the connection between polyploidy and diversification actually been tested?

    PubMed

    Kellogg, Elizabeth A

    2016-04-01

    Many major clades of angiosperms have several whole genome duplications (polyploidization events) in their distant past, suggesting that polyploidy drives or at least permits diversification. However, data on recently diverged groups are more equivocal, finding little evidence of elevated diversification following polyploidy. The discrepancy may be attributable at least in part to methodology. Many studies use indirect methods, such as chromosome numbers, genome size, and Ks plots, to test polyploidy, although these approaches can be misleading, and often lack sufficient resolution. A direct test of diversification following polyploidy requires a sequence-based approach that traces the history of nuclear genomes rather than species. These methods identify the point of coalescence of ancestral genomes, but may be misleading about the time and thus the extent of diversification. Limitations of existing methods mean that the connection between polyploidy and diversification has not been rigorously tested and remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Pretest Caluculations of Temperature Changes for Field Thermal Conductivity Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N.S. Brodsky

    A large volume fraction of the potential monitored geologic repository at Yucca Mountain may reside in the Tptpll (Tertiary, Paintbrush Group, Topopah Spring Tuff, crystal poor, lower lithophysal) lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters. A series of thermal conductivity field tests are planned in the Enhanced Characterization of the Repository Block (ECRB) Cross Drift. The objective of the pretest calculation described in this document is to predict changes in temperatures in the surrounding rock for these tests for a given heater power and a set of thermal transportmore » properties. The calculation can be extended, as described in this document, to obtain thermal conductivity, thermal capacitance (density x heat capacity, J {center_dot} m{sup -3} {center_dot} K{sup -1}), and thermal diffusivity from the field data. The work has been conducted under the ''Technical Work Plan For: Testing and Monitoring'' (BSC 2001). One of the outcomes of this analysis is to determine the initial output of the heater. This heater output must be sufficiently high that it will provide results in a reasonably short period of time (within several weeks or a month) and be sufficiently high that the heat increase is detectable by the instruments employed in the test. The test will be conducted in stages and heater output will be step increased as the test progresses. If the initial temperature is set too high, the experiment will not have as many steps and thus fewer thermal conductivity data points will result.« less

  2. First annual report : automotive collision avoidance system field operational test

    DOT National Transportation Integrated Search

    2002-05-01

    In June of 1999, the National Highway Traffic Safety Administration entered into a cooperative research agreement with General Motors to advance the state-of-the-art of rear-end collision warning technology and conduct a field operational test of a f...

  3. WSDOT intermodal data linkages : ITS field operational test evaluation plan

    DOT National Transportation Integrated Search

    2001-03-28

    In mid-1999, the U.S. Department of Transportation (USDOT) awarded funding for an Intermodal ITS Field Operational Test (FOT) to a regional consortium led by the Washington State DOT (WSDOT). The primary focus of this WSDOT Intermodal FOT is to...

  4. Acadia National Park ITS field operational test : key informant interviews

    DOT National Transportation Integrated Search

    2003-03-01

    This document reflects the ideas and opinions of a group of key informants and stakeholders involved in the Field Operational Test of ITS components in and around Acadia National Park from 1999 through 2002. The stakeholders were involved in the plan...

  5. Ecopa: actual status and plans.

    PubMed

    Rogiers, Vera

    2003-01-01

    Ecopa, the European Consensus Platform on alternatives, is an international not-for-profit organization, based in Belgium and complying with Belgium law. It is the only quadripartite organization at EU level, which is promoting the 3R-Alternatives at the European level. Ecopa brings together National Consensus Platforms on alternative methods. Consensus means that all parties concerned are represented: animal welfare, industry, academia and governmental institutions. Ecopa actually counts 14 National Platforms of Member States (or future Member States), (8 full members, platforms of Austria, Belgium, Finland, Germany, The Netherlands, Spain, Switzerland and United Kingdom and six associate members being Czech Republic, Denmark, Italy, Norway, Poland and Sweden) and has three working groups. The fields of interest of these working groups change according to the needs and were until now concerned with (i) the 6th Framework Programme of the EC for Research, Technological Development and Demonstration Activities, (ii) the EC White Paper Strategy for a Future EU Chemicals Policy and (iii) the formation & educational programmes on alternative methods. Ecopa is thus uniquely placed and has huge expertise to offer to the debate around scientific and politically-linked topics. It has to be considered a key stakeholder by the European Commission and Parliament (http://ecopa.vub.ac.be) or http://ecopa.tsx.org).

  6. Field Test to Evaluate Deep Borehole Disposal.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, Ernest; Brady, Patrick Vane.; Clark, Andrew Jordan

    The U.S. Department of Energy (DOE) has embarked on the Deep Borehole Field Test (DBFT), which will investigate whether conditions suitable for disposal of radioactive waste can be found at a depth of up to 5 km in the earth’s crust. As planned, the DBFT will demonstrate drilling and construction of two boreholes, one for initial scientific characterization, and the other at a larger diameter such as could be appropriate for waste disposal (the DBFT will not involve radioactive waste). A wide range of geoscience activities is planned for the Characterization Borehole, and an engineering demonstration of test package emplacementmore » and retrieval is planned for the larger Field Test Borehole. Characterization activities will focus on measurements and samples that are important for evaluating the long-term isolation capability of the Deep Borehole Disposal (DBD) concept. Engineering demonstration activities will focus on providing data to evaluate the concept’s operational safety and practicality. Procurement of a scientifically acceptable DBFT site and a site management contractor is now underway. The concept of deep borehole disposal (DBD) for radioactive wastes is not new. It was considered by the National Academy of Science (NAS 1957) for liquid waste, studied in the 1980’s in the U.S. (Woodward–Clyde 1983), and has been evaluated by European waste disposal R&D programs in the past few decades (for example, Grundfelt and Crawford 2014; Grundfelt 2010). Deep injection of wastewater including hazardous wastes is ongoing in the U.S. and regulated by the Environmental Protection Agency (EPA 2001). The DBFT is being conducted with a view to use the DBD concept for future disposal of smaller-quantity, DOE-managed wastes from nuclear weapons production (i.e., Cs/Sr capsules and granular solid wastes). However, the concept may also have broader applicability for nations that have a need to dispose of limited amounts of spent fuel from nuclear power reactors

  7. The relation between open-field and emergence tests in a hyperactive mouse model.

    PubMed

    Lalonde, R; Strazielle, C

    2009-12-01

    The relation between open-field and emergence tests was examined in mice with idiopathic hypertension. Spontaneous hypertensive mice (SHM) crossed more segments and reared more often in the open-field than normotensive controls at both age levels. In contrast, grooming episodes decreased only in the older SHM cohort. While young SHM emerged more quickly from a toy object only partially, complete emergence was faster only in the older SHM cohort. In the entire series, open-field segments were inversely correlated with 2- and 4-paw emergence latencies. There was also an inverse correlation between rears and 2-paw emergence but a positive correlation between grooming episodes and both types of emergence. In view of its association with open-field activity, the emergence test may have value in screening potential ADHD therapies.

  8. FSA field test

    NASA Technical Reports Server (NTRS)

    Jaffe, P.; Weaver, R. W.; Lee, R. E.

    1981-01-01

    The 12 continental remote sites were decommissioned. Testing was consolidated into a five-site network consisting of the four Southern California sites and a new Florida site. 16 kW of new state-of-the-art modules were deployed at the five sites. Testing of the old modules continued at the Goldstone site but as a low-priority item. Array testing of modules is considered. Additional new testing capabilities were added. A battery-powered array data logger is discussed. A final set of failure and degradation data was obtained from the modules.

  9. Detailed field test of yaw-based wake steering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fleming, Paul; Churchfield, Matt; Scholbrock, Andrew

    This study describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental design and setup. Lastly, all data collected as partmore » of this field experiment will be archived and made available to the public via the U.S. Department of Energy's Atmosphere to Electrons Data Archive and Portal.« less

  10. Detailed field test of yaw-based wake steering

    DOE PAGES

    Fleming, Paul; Churchfield, Matt; Scholbrock, Andrew; ...

    2016-10-03

    This study describes a detailed field-test campaign to investigate yaw-based wake steering. In yaw-based wake steering, an upstream turbine intentionally misaligns its yaw with respect to the inflow to deflect its wake away from a downstream turbine, with the goal of increasing total power production. In the first phase, a nacelle-mounted scanning lidar was used to verify wake deflection of a misaligned turbine and calibrate wake deflection models. In the second phase, these models were used within a yaw controller to achieve a desired wake deflection. This paper details the experimental design and setup. Lastly, all data collected as partmore » of this field experiment will be archived and made available to the public via the U.S. Department of Energy's Atmosphere to Electrons Data Archive and Portal.« less

  11. Evaluation of the Field Test of Project Information Packages: Volume III--Resource Cost Analysis.

    ERIC Educational Resources Information Center

    Al-Salam, Nabeel; And Others

    The third of three volumes evaluating the first year field test of the Project Information Packages (PIPs) provides a cost analysis study as a key element in the total evaluation. The resource approach to cost analysis is explained and the specific resource methodology used in the main cost analysis of the 19 PIP field-test projects detailed. The…

  12. Evaluation of Actual Nitrogen Losses From a Watershed Preliminary Results of a Case Study in the Po Vally (Northern Italy)

    Treesearch

    Maurizio Borin; Tomaso Bisol; Gabriele Bonaiti; Francesco Morari; Devendra M. Amatya

    2004-01-01

    The evaluation of potential N losses from individual fields is not sufficient to provide an estimate of the actual nitrogen loads reaching the main watercourses and therefore becoming a relevant source of pollution. Along the travel path from a field to the outlet of a watershed several biogeochemical processes may occur, leading to significant changes in the N amount...

  13. 19 CFR 162.79b - Recovery of actual loss of duties, taxes and fees or actual loss of revenue.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Recovery of actual loss of duties, taxes and fees or actual loss of revenue. 162.79b Section 162.79b Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) INSPECTION, SEARCH, AND SEIZURE...

  14. Three-Dimensional Imaging in Rhinoplasty: A Comparison of the Simulated versus Actual Result.

    PubMed

    Persing, Sarah; Timberlake, Andrew; Madari, Sarika; Steinbacher, Derek

    2018-05-22

    Computer imaging has become increasingly popular for rhinoplasty. Three-dimensional (3D) analysis permits a more comprehensive view from multiple vantage points. However, the predictability and concordance between the simulated and actual result have not been morphometrically studied. The purpose of this study was to aesthetically and quantitatively compare the simulated to actual rhinoplasty result. A retrospective review of 3D images (VECTRA, Canfield) for rhinoplasty patients was performed. Images (preop, simulated, and actual) were randomized. A blinded panel of physicians rated the images (1 = poor, 5 = excellent). The image series considered "best" was also recorded. A quantitative assessment of nasolabial angle and tip projection was compared. Paired and two-sample t tests were performed for statistical analysis (P < 0.05 as significant). Forty patients were included. 67.5% of preoperative images were rated as poor (mean = 1.7). The simulation received a mean score of 2.9 (good in 60% of cases). 82.5% of actual cases were rated good to excellent (mean 3.4) (P < 0.001). Overall, the panel significantly preferred the actual postoperative result in 77.5% of cases compared to the simulation in 22.5% of cases (P < 0.001). The actual nasal tip was more projected compared to the simulations for both males and females. There was no significant difference in nasal tip rotation between simulated and postoperative groups. 3D simulation is a powerful communication and planning tool in rhinoplasty. In this study, the actual result was deemed more aesthetic than the simulated image. Surgeon experience is important to translate the plan and achieve favorable postoperative results. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  15. SMART empirical approaches for predicting field performance of PV modules from results of reliability tests

    NASA Astrophysics Data System (ADS)

    Hardikar, Kedar Y.; Liu, Bill J. J.; Bheemreddy, Venkata

    2016-09-01

    Gaining an understanding of degradation mechanisms and their characterization are critical in developing relevant accelerated tests to ensure PV module performance warranty over a typical lifetime of 25 years. As newer technologies are adapted for PV, including new PV cell technologies, new packaging materials, and newer product designs, the availability of field data over extended periods of time for product performance assessment cannot be expected within the typical timeframe for business decisions. In this work, to enable product design decisions and product performance assessment for PV modules utilizing newer technologies, Simulation and Mechanism based Accelerated Reliability Testing (SMART) methodology and empirical approaches to predict field performance from accelerated test results are presented. The method is demonstrated for field life assessment of flexible PV modules based on degradation mechanisms observed in two accelerated tests, namely, Damp Heat and Thermal Cycling. The method is based on design of accelerated testing scheme with the intent to develop relevant acceleration factor models. The acceleration factor model is validated by extensive reliability testing under different conditions going beyond the established certification standards. Once the acceleration factor model is validated for the test matrix a modeling scheme is developed to predict field performance from results of accelerated testing for particular failure modes of interest. Further refinement of the model can continue as more field data becomes available. While the demonstration of the method in this work is for thin film flexible PV modules, the framework and methodology can be adapted to other PV products.

  16. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24

  17. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary M. Blythe

    2006-03-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive

  18. Testing strong-field gravity with tidal Love numbers

    NASA Astrophysics Data System (ADS)

    Cardoso, Vitor; Franzin, Edgardo; Maselli, Andrea; Pani, Paolo; Raposo, Guilherme

    2017-04-01

    The tidal Love numbers (TLNs) encode the deformability of a self-gravitating object immersed in a tidal environment and depend significantly both on the object's internal structure and on the dynamics of the gravitational field. An intriguing result in classical general relativity is the vanishing of the TLNs of black holes. We extend this result in three ways, aiming at testing the nature of compact objects: (i) we compute the TLNs of exotic compact objects, including different families of boson stars, gravastars, wormholes, and other toy models for quantum corrections at the horizon scale. In the black-hole limit, we find a universal logarithmic dependence of the TLNs on the location of the surface. (ii) We compute the TLNs of black holes beyond vacuum general relativity, including Einstein-Maxwell, Brans-Dicke, and Chern-Simons gravity. (iii) We assess the ability of present and future gravitational-wave detectors to measure the TLNs of these objects, including the first analysis of TLNs with LISA. Both LIGO, ET, and LISA can impose interesting constraints on boson stars, while LISA is able to probe even extremely compact objects. We argue that the TLNs provide a smoking gun of new physics at the horizon scale and that future gravitational-wave measurements of the TLNs in a binary inspiral provide a novel way to test black holes and general relativity in the strong-field regime.

  19. 40 CFR 74.22 - Actual SO2 emissions rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Actual SO2 emissions rate. 74.22... (CONTINUED) SULFUR DIOXIDE OPT-INS Allowance Calculations for Combustion Sources § 74.22 Actual SO2 emissions... actual SO2 emissions rate shall be 1985. (2) For combustion sources that commenced operation after...

  20. Wind-Tunnel Survey of an Oscillating Flow Field for Application to Model Helicopter Rotor Testing

    NASA Technical Reports Server (NTRS)

    Mirick, Paul H.; Hamouda, M-Nabil H.; Yeager, William T., Jr.

    1990-01-01

    A survey was conducted of the flow field produced by the Airstream Oscillator System (AOS) in the Langley Transonic Dynamics Tunnel (TDT). The magnitude of a simulated gust field was measured at 15 locations in the plane of a typical model helicopter rotor when tested in the TDT using the Aeroelastic Rotor Experimental System (ARES) model. These measurements were made over a range of tunnel dynamic pressures typical of those used for an ARES test. The data indicate that the gust field produced by the AOS is non-uniform across the tunnel test section, but should be sufficient to excite a model rotor.

  1. Benchmarking the Performance of Mobile Laser Scanning Systems Using a Permanent Test Field

    PubMed Central

    Kaartinen, Harri; Hyyppä, Juha; Kukko, Antero; Jaakkola, Anttoni; Hyyppä, Hannu

    2012-01-01

    The performance of various mobile laser scanning systems was tested on an established urban test field. The test was connected to the European Spatial Data Research (EuroSDR) project “Mobile Mapping—Road Environment Mapping Using Mobile Laser Scanning”. Several commercial and research systems collected laser point cloud data on the same test field. The system comparisons focused on planimetric and elevation errors using a filtered digital elevation model, poles, and building corners as the reference objects. The results revealed the high quality of the point clouds generated by all of the tested systems under good GNSS conditions. With all professional systems properly calibrated, the elevation accuracy was better than 3.5 cm up to a range of 35 m. The best system achieved a planimetric accuracy of 2.5 cm over a range of 45 m. The planimetric errors increased as a function of range, but moderately so if the system was properly calibrated. The main focus on mobile laser scanning development in the near future should be on the improvement of the trajectory solution, especially under non-ideal conditions, using both improvements in hardware and software. Test fields are relatively easy to implement in built environments and they are feasible for verifying and comparing the performance of different systems and also for improving system calibration to achieve optimum quality.

  2. Discussion of comparison study of hydraulic fracturing models -- Test case: GRI Staged Field Experiment No. 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleary, M.P.

    This paper provides comments to a companion journal paper on predictive modeling of hydraulic fracturing patterns (N.R. Warpinski et. al., 1994). The former paper was designed to compare various modeling methods to demonstrate the most accurate methods under various geologic constraints. The comments of this paper are centered around potential deficiencies in the former authors paper which include: limited actual comparisons offered between models, the issues of matching predictive data with that from related field operations was lacking or undocumented, and the relevance/impact of accurate modeling on the overall hydraulic fracturing cost and production.

  3. Artificial testing targets with controllable blur for adaptive optics microscopes

    NASA Astrophysics Data System (ADS)

    Hattori, Masayuki; Tamada, Yosuke; Murata, Takashi; Oya, Shin; Hasebe, Mitsuyasu; Hayano, Yutaka; Kamei, Yasuhiro

    2017-08-01

    This letter proposes a method of configuring a testing target to evaluate the performance of adaptive optics microscopes. In this method, a testing slide with fluorescent beads is used to simultaneously determine the point spread function and the field of view. The point spread function is reproduced to simulate actual biological samples by etching a microstructure on the cover glass. The fabrication process is simplified to facilitate an onsite preparation. The artificial tissue consists of solid materials and silicone oil and is stable for use in repetitive experiments.

  4. 29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. PLAN OF THE ARVFS FIELD TEST FACILITY SHOWING BUNKER, CABLE CHASE, SHIELDING TANK AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-1. INEL INDEX CODE NUMBER: 075 0701 851 151970. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  5. 'I didn't see that coming': simulated visual fields and driving hazard perception test performance.

    PubMed

    Glen, Fiona C; Smith, Nicholas D; Jones, Lee; Crabb, David P

    2016-09-01

    Evidence is limited regarding specific types of visual field loss associated with unsafe driving. We use novel gaze-contingent software to examine the effect of simulated visual field loss on computer-based driving hazard detection with the specific aim of testing the impact of scotomata located to the right and left of fixation. The 'hazard perception test' is a component of the UK driving licence examination, which measures speed of detecting 15 different hazards in a series of real-life driving films. We have developed a novel eye-tracking and computer set up capable of generating a realistic gaze-contingent scotoma simulation (GazeSS) overlaid on film content. Thirty drivers with healthy vision completed three versions of the hazard perception test in a repeated measures experiment. In two versions, GazeSS simulated a scotoma in the binocular field of view to the left or right of fixation. A third version was unmodified to establish baseline performance. Participants' mean baseline hazard perception test score was 51 ± 7 (out of 75). This reduced to 46 ± 9 and 46 ± 11 when completing the task with a binocular visual field defect located to the left and right of fixation, respectively. While the main effect of simulated visual field loss on performance was statistically significant (p = 0.007), there were no average differences in the experimental conditions where a scotoma was located in the binocular visual field to the right or left of fixation. Simulated visual field loss impairs driving hazard detection on a computer-based test. There was no statistically significant difference in average performance when the simulated scotoma was located to the right or left of fixation of the binocular visual field, but certain types of hazard caused more difficulties than others. © 2016 Optometry Australia.

  6. Field test of the superconducting gravimeter as a hydrologic sensor.

    PubMed

    Wilson, Clark R; Scanlon, Bridget; Sharp, John; Longuevergne, Laurent; Wu, Hongqiu

    2012-01-01

    We report on a field test of a transportable version of a superconducting gravimeter (SG) intended for groundwater storage monitoring. The test was conducted over a 6-month period at a site adjacent to a well in the recharge zone of the karstic Edwards Aquifer, a major groundwater resource in central Texas. The purpose of the study was to assess requirements for unattended operation of the SG in a field setting and to obtain a gravimetric estimate of aquifer specific yield. The experiment confirmed successful operation of the SG, but water level changes were small (<0.3 m) leading to uncertainty in the estimate of specific yield. Barometric pressure changes were the dominant cause of both water level variations and non-tidal gravity changes. The specific yield estimate (0.26) is larger than most published values and dependent mainly on low frequency variations in residual gravity and water level time series. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  7. The Impact of Congruency Between Preferred and Actual Learning Environments on Tenth Graders' Science Literacy in Taiwan

    NASA Astrophysics Data System (ADS)

    Chang, Chun-Yen; Yeh, Ting-Kuang; Lin, Chun-Yen; Chang, Yueh-Hsia; Chen, Chia-Li D.

    2010-08-01

    This study explored the effects of congruency between preferred and actual learning environment (PLE & ALE) perceptions on students' science literacy in terms of science concepts, attitudes toward science, and the understanding of the nature of science in an innovative curriculum of High Scope Project, namely Sci-Tech Mind and Humane Heart (STMHH). A pre-/post-treatment experiment was conducted with 34 Taiwanese tenth graders involved in this study. Participating students' preferred learning environment perception and pre-instruction scientific literacy were evaluated before the STMHH curriculum. Their perceptions toward the actual STMHH learning environment and post-instruction scientific literacy were also examined after the STMHH. Students were categorized into two groups; "preferred alignment with actual learning environment" (PAA) and "preferred discordant with actual learning environment" (PDA), according to their PLEI and ALEI scores. The results of this study revealed that most of the students in this study preferred learning in a classroom environment where student-centered and teacher-centered learning environments coexisted. Furthermore, the ANCOVA analysis showed marginally statistically significant difference between groups in terms of students' post-test scores on scientific literacy with the students' pre-test scores as the covariate. As a pilot study with a small sample size aiming to probe the research direction of this problem, the result of marginally statistically significant and approaching large sized effect magnitude is likely to implicate that the congruency between preferred and actual learning environments on students' scientific literacy is noteworthy. Future study of this nature appears to merit further replications and investigations.

  8. Finding Kids with Special Needs: the Background, Development, Field Test and Validation.

    ERIC Educational Resources Information Center

    Resource Management Systems, Inc., Carmel, CA.

    Described are the development of "Findings Kids with Special Needs" (FKSN), a instrument to identify children's learning problems and gifted students; results of field testing with 24,825 children, kindergarten through grade 8, in 110 schools; and validation procedures. Discussed is test construction, including incorporation of 12…

  9. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    NASA Technical Reports Server (NTRS)

    Trout, Dawn; Burford, Janessa

    2012-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite . a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  10. Model to Test Electric Field Comparisons in a Composite Fairing Cavity

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Burford, Janessa

    2013-01-01

    Evaluating the impact of radio frequency transmission in vehicle fairings is important to sensitive spacecraft. This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. This work is an extension of the bare aluminum fairing perfect electric conductor (PEC) model. Test and model data correlation is shown.

  11. Intelligent transportation systems field operational test cross-cutting study : emergency notification and response.

    DOT National Transportation Integrated Search

    1998-09-01

    Emergency Notification and Response report summarizes and interprets the results of two Field Operational Tests (FOTs) that included emergency notification and response system components. The tests included in this report are: Colorado Mayday and Pug...

  12. Synchrotron Intensity Gradients as Tracers of Interstellar Magnetic Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazarian, A.; Yuen, Ka Ho; Lee, Hyeseung

    On the basis of the modern understanding of MHD turbulence, we propose a new way of using synchrotron radiation: using synchrotron intensity gradients (SIGs) for tracing astrophysical magnetic fields. We successfully test the new technique using synthetic data obtained with 3D MHD simulations and provide the demonstration of the practical utility of the technique by comparing the directions of magnetic fields that are obtained with PLANCK synchrotron intensity data to the directions obtained with PLANCK synchrotron polarization data. We demonstrate that the SIGs can reliably trace magnetic fields in the presence of noise and can provide detailed maps of magneticmore » field directions. We also show that the SIGs are relatively robust for tracing magnetic fields while the low spatial frequencies of the synchrotron image are removed. This makes the SIGs applicable to the tracing of magnetic fields using interferometric data with single-dish measurement absent. We discuss the synergy of using the SIGs together with synchrotron polarization in order to find the actual direction of the magnetic fields and quantify the effects of Faraday rotation as well as with other ways of studying astrophysical magnetic fields. We test our method in the presence of noise and the resolution effects. We stress the complementary nature of the studies using the SIG technique and those employing the recently introduced velocity gradient techniques that trace magnetic fields using spectroscopic data.« less

  13. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured bymore » the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.« less

  14. Students' performance in accounting: differential effect of field dependence-independence as a learning style.

    PubMed

    Bernardi, Richard A

    2003-08-01

    This study examined the differential moderating effects associated with field dependence-independence and perceptions of stress on students' performance after controlling for SAT Mathematics and Verbal scores as well as students' actual effort on homework. The average performance of 178 third-year accounting majors over three examinations was used to evaluate their understanding of financial accounting. The students also took the Group Embedded Figures Test. While the data indicate that the most significant variables were students' effort, SAT Verbal scores, and their perceptions of stress, these variables were differentially associated with students' performance depending upon whether the student was classified as a field-independent or field-dependent learner.

  15. NEPP Update of Independent Single Event Upset Field Programmable Gate Array Testing

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; Label, Kenneth; Campola, Michael; Pellish, Jonathan

    2017-01-01

    This presentation provides a NASA Electronic Parts and Packaging (NEPP) Program update of independent Single Event Upset (SEU) Field Programmable Gate Array (FPGA) testing including FPGA test guidelines, Microsemi RTG4 heavy-ion results, Xilinx Kintex-UltraScale heavy-ion results, Xilinx UltraScale+ single event effect (SEE) test plans, development of a new methodology for characterizing SEU system response, and NEPP involvement with FPGA security and trust.

  16. Direct-field acoustic testing of a flight system : logistics, challenges, and results.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stasiunas, Eric Carl; Gurule, David Joseph; Babuska, Vit

    2010-10-01

    Before a spacecraft can be considered for launch, it must first survive environmental testing that simulates the launch environment. Typically, these simulations include vibration testing performed using an electro-dynamic shaker. For some spacecraft however, acoustic excitation may provide a more severe loading environment than base shaker excitation. Because this was the case for a Sandia Flight System, it was necessary to perform an acoustic test prior to launch in order to verify survival due to an acoustic environment. Typically, acoustic tests are performed in acoustic chambers, but because of scheduling, transportation, and cleanliness concerns, this was not possible. Instead, themore » test was performed as a direct field acoustic test (DFAT). This type of test consists of surrounding a test article with a wall of speakers and controlling the acoustic input using control microphones placed around the test item, with a closed-loop control system. Obtaining the desired acoustic input environment - proto-flight random noise input with an overall sound pressure level (OASPL) of 146.7 dB-with this technique presented a challenge due to several factors. An acoustic profile with this high OASPL had not knowingly been obtained using the DFAT technique prior to this test. In addition, the test was performed in a high-bay, where floor space and existing equipment constrained the speaker circle diameter. And finally, the Flight System had to be tested without contamination of the unit, which required a contamination bag enclosure of the test unit. This paper describes in detail the logistics, challenges, and results encountered while performing a high-OASPL, direct-field acoustic test on a contamination-sensitive Flight System in a high-bay environment.« less

  17. FIELD TEST OF AIR SPARGING COUPLED WITH SOIL VAPOR EXTRACTION

    EPA Science Inventory

    A controlled field study was designed and conducted to assess the performance of air sparging for remediation of petroleum fuel and solvent contamination in a shallow (3-m deep) groundwater aquifer. Sparging was performed in an insolation test cell (5 m by 3 m by 8-m deep). A soi...

  18. Development and Field Tests of the Army Work Environment Questionnaire

    DTIC Science & Technology

    1987-05-01

    from the low teens to the mid-twenties), a number of consistent trends were found in the pattern of relationships. In both field tests, the largest...identifying impediments to productivity (UPRDC TR-81-18). San Diego, CA: Navy Personnel Research and Development Center. 39 Appendix A iiOONMwc IUCIDU PORN

  19. Impact of Different Visual Field Testing Paradigms on Sample Size Requirements for Glaucoma Clinical Trials.

    PubMed

    Wu, Zhichao; Medeiros, Felipe A

    2018-03-20

    Visual field testing is an important endpoint in glaucoma clinical trials, and the testing paradigm used can have a significant impact on the sample size requirements. To investigate this, this study included 353 eyes of 247 glaucoma patients seen over a 3-year period to extract real-world visual field rates of change and variability estimates to provide sample size estimates from computer simulations. The clinical trial scenario assumed that a new treatment was added to one of two groups that were both under routine clinical care, with various treatment effects examined. Three different visual field testing paradigms were evaluated: a) evenly spaced testing, b) United Kingdom Glaucoma Treatment Study (UKGTS) follow-up scheme, which adds clustered tests at the beginning and end of follow-up in addition to evenly spaced testing, and c) clustered testing paradigm, with clusters of tests at the beginning and end of the trial period and two intermediary visits. The sample size requirements were reduced by 17-19% and 39-40% using the UKGTS and clustered testing paradigms, respectively, when compared to the evenly spaced approach. These findings highlight how the clustered testing paradigm can substantially reduce sample size requirements and improve the feasibility of future glaucoma clinical trials.

  20. Casting the Coronal Magnetic Field Reconstructions with Magnetic Field Constraints above the Photosphere in 3D Using MHD Bifrost Model

    NASA Astrophysics Data System (ADS)

    Fleishman, G. D.; Anfinogentov, S.; Loukitcheva, M.; Mysh'yakov, I.; Stupishin, A.

    2017-12-01

    Measuring and modeling coronal magnetic field, especially above active regions (ARs), remains one of the central problems of solar physics given that the solar coronal magnetism is the key driver of all solar activity. Nowadays the coronal magnetic field is often modelled using methods of nonlinear force-free field reconstruction, whose accuracy has not yet been comprehensively assessed. Given that the coronal magnetic probing is routinely unavailable, only morphological tests have been applied to evaluate performance of the reconstruction methods and a few direct tests using available semi-analytical force-free field solution. Here we report a detailed casting of various tools used for the nonlinear force-free field reconstruction, such as disambiguation methods, photospheric field preprocessing methods, and volume reconstruction methods in a 3D domain using a 3D snapshot of the publicly available full-fledged radiative MHD model. We take advantage of the fact that from the realistic MHD model we know the magnetic field vector distribution in the entire 3D domain, which enables us to perform "voxel-by-voxel" comparison of the restored magnetic field and the true magnetic field in the 3D model volume. Our tests show that the available disambiguation methods often fail at the quiet sun areas, where the magnetic structure is dominated by small-scale magnetic elements, while they work really well at the AR photosphere and (even better) chromosphere. The preprocessing of the photospheric magnetic field, although does produce a more force-free boundary condition, also results in some effective `elevation' of the magnetic field components. The effective `elevation' height turns out to be different for the longitudinal and transverse components of the magnetic field, which results in a systematic error in absolute heights in the reconstructed magnetic data cube. The extrapolation performed starting from actual AR photospheric magnetogram (i.e., without preprocessing) are

  1. Development and proposed implementation of a field permeability test for a asphalt concrete.

    DOT National Transportation Integrated Search

    2001-07-01

    The objectives of this study were as follows: : 1) To review research performed by others and determine the state-of-the-art of field permeability measurements; : 2) To review current laboratory permeability testing devices and their testing procedur...

  2. Analyzing actual risk in malaria-deferred donors through selective serologic testing.

    PubMed

    Nguyen, Megan L; Goff, Tami; Gibble, Joan; Steele, Whitney R; Leiby, David A

    2013-08-01

    Approximately 150,000 US blood donors are deferred annually for travel to malaria-endemic areas. However, the majority do not travel to the high-risk areas of Africa associated with transfusion-transmitted malaria (TTM) but visit low-risk areas such as Mexico. This study tests for Plasmodium infection among malaria-deferred donors, particularly those visiting Mexico. Blood donors deferred for malaria risk (travel, residence, or previous infection) provided blood samples and completed a questionnaire. Plasma was tested for Plasmodium antibodies by enzyme immunoassay (EIA); repeat-reactive (RR) samples were considered positive and tested by real-time polymerase chain reaction (PCR). Accepted donors provided background testing data. During 2005 to 2011, a total of 5610 malaria-deferred donors were tested by EIA, including 5412 travel deferrals. Overall, 88 (1.6%) were EIA RR; none were PCR positive. Forty-nine (55.7%) RR donors previously had malaria irrespective of deferral category, including 34 deferred for travel. Among 1121 travelers to Mexico, 90% visited Quintana Roo (no or very low risk), but just 2.2% visited Oaxaca/Chiapas (moderate or high risk). Only two Mexican travelers tested RR; both previously had malaria not acquired in Mexico. Travel to Mexico represents a large percentage of US donors deferred for malaria risk; however, these donors primarily visit no- or very-low-risk areas. No malaria cases acquired in Mexico were identified thereby supporting previous risk estimates. Consideration should be given to allowing blood donations from U.S. donors who travel to Quintana Roo and other low-risk areas in Mexico. A more effective approach to preventing TTM would be to defer all donors with a history of malaria, even if remote. © 2012 American Association of Blood Banks.

  3. A microcomputer-based testing station for dynamic and static testing of protective relay systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, W.J.; Li, R.J.; Gu, J.C.

    1995-12-31

    Dynamic and static relay performance testing before installation in the field is a subject of great interest to utility relay engineers. The common practice in utility testing of new relays is to put the new unit to be tested in parallel with an existing functioning relay in the system, wait until an actual transient occurs and then observe and analyze the performance of new relay. It is impossible to have a thorough test of the protective relay system through this procedure. An equipment, Microcomputer-Based Testing Station (or PC-Based Testing Station), that can perform both static and dynamic testing of themore » relay is described in this paper. The Power System Simulation Laboratory at the University of Texas at Arlington is a scaled-down, three-phase, physical power system which correlates well with the important components for a real power system and is an ideal facility for the dynamic and static testing of protective relay systems. A brief introduction to the configuration of this laboratory is presented. Test results of several protective functions by using this laboratory illustrate the usefulness of this test set-up.« less

  4. The Frictional Force with Respect to the Actual Contact Surface

    NASA Technical Reports Server (NTRS)

    Holm, Ragnar

    1944-01-01

    Hardy's statement that the frictional force is largely adhesion, and to a lesser extent, deformation energy is proved by a simple experiment. The actual contact surface of sliding contacts and hence the friction per unit of contact surface was determined in several cases. It was found for contacts in normal atmosphere to be about one-third t-one-half as high as the macroscopic tearing strength of the softest contact link, while contacts annealed in vacuum and then tested, disclosed frictional forces which are greater than the macroscopic strength.

  5. Field relevance of a suite of rollover tests to real-world crashes and injuries.

    PubMed

    Parenteau, Chantal S; Viano, David C; Shah, Minoo; Gopal, Madana; Davies, John; Nichols, David; Broden, Johan

    2003-01-01

    The objective of this study was to assess the distribution of rollover accidents occurring in the field and to compare the vehicle kinematics in the predominant field crash modes with available laboratory tests. For this purpose, US accident data were analyzed to identify types and circumstances for vehicle rollovers. Rollovers were most commonly induced when the lateral motion of the vehicle was suddenly slowed or stopped. This type of rollover mechanism is referred to as "trip-over". Trip-overs accounted for 57% of passenger car and 51% of light truck vehicle (LTV) rollovers. More than 90% of trip-overs were initiated by ground contact. Fall-overs were the second most common rollover type, accounting for 13% of passenger car and 15% of LTV rollovers. Bounce-overs only accounted for 8% of both passenger car and LTV rollovers. The FMVSS 208 dolly and the ADAC corkscrew rollover tests are well-known laboratory tests, but do not simulate many of the real-world rollovers. Three additional tests have been devised to more fully address the field relevant conditions identified in this study. To do so, assumptions were made and adding the new laboratory tests (soil-trip, curb-trip and ditch fall-over) increases representativeness to 83% of passenger car and 75% of LTV rollovers reported in the field. Accident data were also used to identify injuries in belted drivers so the information could later be used to better understand occupant kinematics in various roll conditions. The injury distribution for belted/non-ejected drivers was assessed for trip-over, fall-over and bounce-over accidents. Serious injuries (AIS 3+) were most common to the head and thorax, in particular for bounce-overs. Head injuries occurred from contact with the roof, pillar and the interior, while thoracic injuries resulted from contact with the interior and steering wheel assembly. Field data are useful in the development of laboratory test conditions for rollovers as it provides insights on the

  6. From Test Takers to Test Makers

    ERIC Educational Resources Information Center

    Smith, Kari

    2009-01-01

    As a classroom teacher, Kari Smith realized that traditional objective tests don't always assess what students actually know. But tests are so deeply embedded in the education system that it would be difficult to do away with them entirely. Smith decided to make tests into learning tools. In this article, Smith describes three strategies for…

  7. Acoustical characteristics of the NASA Langley full scale wind tunnel test section

    NASA Technical Reports Server (NTRS)

    Abrahamson, A. L.; Kasper, P. K.; Pappa, R. S.

    1975-01-01

    The full-scale wind tunnel at NASA-Langley Research Center was designed for low-speed aerodynamic testing of aircraft. Sound absorbing treatment has been added to the ceiling and walls of the tunnel test section to create a more anechoic condition for taking acoustical measurements during aerodynamic tests. The results of an experimental investigation of the present acoustical characteristics of the tunnel test section are presented. The experimental program included measurements of ambient nosie levels existing during various tunnel operating conditions, investigation of the sound field produced by an omnidirectional source, and determination of sound field decay rates for impulsive noise excitation. A comparison of the current results with previous measurements shows that the added sound treatment has improved the acoustical condition of the tunnel test section. An analysis of the data indicate that sound reflections from the tunnel ground-board platform could create difficulties in the interpretation of actual test results.

  8. Motivators to participation in actual HIV vaccine trials.

    PubMed

    Dhalla, Shayesta; Poole, Gary

    2014-02-01

    An examination of actual HIV vaccine trials can contribute to an understanding of motivators for participation in these studies. Analysis of these motivators reveals that they can be categorized as social and personal benefits. Social benefits are generally altruistic, whereas personal benefits are psychological, physical, and financial. In this systematic review, the authors performed a literature search for actual preventive HIV vaccine trials reporting motivators to participation. Of studies conducted in the Organization for Economic Co-operation and Development (OECD) countries, the authors retrieved 12 studies reporting on social benefits and seven reporting on personal benefits. From the non-OECD countries, nine studies reported on social benefits and eight studies on personal benefits. Social benefits were most frequently described on macroscopic, altruistic levels. Personal benefits were most frequently psychological in nature. Rates of participation were compared between the OECD and the non-OECD countries. Knowledge of actual motivators in specific countries and regions can help target recruitment in various types of actual HIV vaccine trials.

  9. Inferring electric fields and currents from ground magnetometer data - A test with theoretically derived inputs

    NASA Technical Reports Server (NTRS)

    Wolf, R. A.; Kamide, Y.

    1983-01-01

    Advanced techniques considered by Kamide et al. (1981) seem to have the potential for providing observation-based high time resolution pictures of the global ionospheric current and electric field patterns for interesting events. However, a reliance on the proposed magnetogram-inversion schemes for the deduction of global ionospheric current and electric field patterns requires proof that reliable results are obtained. 'Theoretical' tests of the accuracy of the magnetogram inversion schemes have, therefore, been considered. The present investigation is concerned with a test, involving the developed KRM algorithm and the Rice Convection Model (RCM). The test was successful in the sense that there was overall agreement between electric fields and currents calculated by the RCM and KRM schemes.

  10. Field Test Advisor Perceptions of Center Operations: An Occasional Paper.

    ERIC Educational Resources Information Center

    Goldstein, Marjorie T.

    A 1974 survey was undertaken to determine the extent to which the Curriculum Research and Development Center in Mental Retardation was responsive to the needs of the Social Learning Curriculum field test advisors (FTA's). Thirty-eight FTA's responded. Among the results was a significant positive change in FTA's perceptions of Center functioning.…

  11. 30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. ELEVATION OF ARVFS FIELD TEST FACILITY SHOWING VIEW OF SOUTH SIDE OF FACILITY, INCLUDING BUNKER, CABLE CHASE, SHIELDING TANK, AND FRAME ASSEMBLY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-701-2. INEL INDEX CODE NUMBER: 075 0701 851 151971. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  12. Field test of a motorcycle safety education course for novice riders

    DOT National Transportation Integrated Search

    1982-07-01

    The purpose of this study was to subject the Motorcycle Safety Foundation's Motorcycle Rider Course (MRC) to a large-scale field test designed to evaluate the following aspects of the course: (1) Instructional Effectiveness, (2) User Acceptance, and ...

  13. Field test and finite element of I-345 bridge in Dallas.

    DOT National Transportation Integrated Search

    2009-07-01

    This report documents a field test to determine the stresses at areas where fatigue cracks had formed in the : bridges. Two bridges were instrumented and subjected to controlled truck traffic. In addition, the service fatigue : stresses were evaluate...

  14. Chip and scrub seal field test results for Hwy 17 and Hwy 35.

    DOT National Transportation Integrated Search

    2009-11-09

    This report contains field test results from two pavements located in Mississippi containing chip seals and scrub seals. Limestone aggregate from the same source was used with PASS-CR emulsion. The pavements were tested at three intervals. One or bot...

  15. Rational Behavioral Training and Changes in Self-Actualization.

    ERIC Educational Resources Information Center

    Johnson, Norbert; And Others

    1982-01-01

    Examined the effects on self-actualization of CETA supervisors who participated in a Rational Behavioral Training (RBT) group. The Personal Orientation Inventory (POI) was administered to experimental and control groups before and after the group. Results indicated the RBT experience enabled participants to move toward self-actualization. (RC)

  16. Self-Actualization Effects Of A Marathon Growth Group

    ERIC Educational Resources Information Center

    Jones, Dorothy S.; Medvene, Arnold M.

    1975-01-01

    This study examined the effects of a marathon group experience on university student's level of self-actualization two days and six weeks after the experience. Gains in self-actualization as a result of marathon group participation depended upon an individual's level of ego strength upon entering the group. (Author)

  17. Evaluation of the Mack Intelligent Vehicle Field Operational Test: September 2006

    DOT National Transportation Integrated Search

    2006-09-01

    This report presents the final results of an independent evaluation of the U.S. Department of Transportation (USDOT) Mack Intelligent Vehicle Initiative (IVI) Field Operational Test (FOT). The IVI is a cooperative effort to conduct FOTs of advanced i...

  18. Integrated vehicle-based safety systems field operational test final program report.

    DOT National Transportation Integrated Search

    2011-06-01

    "This document presents results from the light-vehicle and heavy-truck field operational tests performed as part of the Integrated Vehicle-Based Safety Systems (IVBSS) program. The findings are the result of analyses performed by the University of Mi...

  19. Integrated Vehicle-Based Safety Systems Field Operational Test : Final Program Report

    DOT National Transportation Integrated Search

    2011-06-01

    This document presents results from the light-vehicle and heavy-truck field operational tests performed as part of the Integrated Vehicle-Based Safety Systems (IVBSS) program. The findings are the result of analyses performed by the University of Mic...

  20. Intelligent cruise control field operational test. Vol II, Appendices A-F

    DOT National Transportation Integrated Search

    1998-05-01

    This document reports on a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). The main goal of the work is to characterize safety and comfort issues that are fundamental to human inte...

  1. Automotive collision avoidance field operational test : warning cue implementation summary report

    DOT National Transportation Integrated Search

    2002-05-23

    This report documents the human factors work conducted from January to June 2001 to design and evaluate the driver-vehicle-interface (DVI) for the Automotive Collision Avoidance System Field Operational Test (ACAS FOT) program. The objective was to d...

  2. Tracing Actual Causes

    DTIC Science & Technology

    2016-08-08

    actual values for variables in the SEM ), and an event e with M ,~u |= e, our definition answers the question : Which paths of the causal network G( M ...for each variable and a directed edge from vari- able X to Y if the equation for computing X uses Y . Given an SEM M , a context ~u (that supplies the...caused the event e1? Our definition answers this question as a set of causal slices, where each causal slice is a subgraph of G( M ). All paths in each

  3. Non-specific physical symptoms in relation to actual and perceived proximity to mobile phone base stations and powerlines

    PubMed Central

    2011-01-01

    Background Evidence about a possible causal relationship between non-specific physical symptoms (NSPS) and exposure to electromagnetic fields (EMF) emitted by sources such as mobile phone base stations (BS) and powerlines is insufficient. So far little epidemiological research has been published on the contribution of psychological components to the occurrence of EMF-related NSPS. The prior objective of the current study is to explore the relative importance of actual and perceived proximity to base stations and psychological components as determinants of NSPS, adjusting for demographic, residency and area characteristics. Methods Analysis was performed on data obtained in a cross-sectional study on environment and health in 2006 in the Netherlands. In the current study, 3611 adult respondents (response rate: 37%) in twenty-two Dutch residential areas completed a questionnaire. Self-reported instruments included a symptom checklist and assessment of environmental and psychological characteristics. The computation of the distance between household addresses and location of base stations and powerlines was based on geo-coding. Multilevel regression models were used to test the hypotheses regarding the determinants related to the occurrence of NSPS. Results After adjustment for demographic and residential characteristics, analyses yielded a number of statistically significant associations: Increased report of NSPS was predominantly predicted by higher levels of self-reported environmental sensitivity; perceived proximity to base stations and powerlines, lower perceived control and increased avoidance (coping) behavior were also associated with NSPS. A trend towards a moderator effect of perceived environmental sensitivity on the relation between perceived proximity to BS and NSPS was verified (p = 0.055). There was no significant association between symptom occurrence and actual distance to BS or powerlines. Conclusions Perceived proximity to BS, psychological

  4. Results of the long range position-determining system tests. [Field Army system

    NASA Technical Reports Server (NTRS)

    Rhode, F. W.

    1973-01-01

    The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

  5. Membrane Accelerated Stress Test Development for Polymer Electrolyte Fuel Cell Durability Validated Using Field and Drive Cycle Testing

    DOE PAGES

    Mukundan, Rangachary; Baker, Andrew M.; Kusoglu, Ahmet; ...

    2018-03-01

    A combined chemical/mechanical accelerated stress test (AST) was developed for proton exchange membrane (PEM) fuel cells based on relative humidity cycling (RHC) between dry and saturated gases at open circuit voltage (OCV). Membrane degradation and failure were investigated using scanning electron microscopy and small- and wide-angle X-ray scattering. Changes to membrane thickness, hydrophilic domain spacing, and crystallinity were observed to be most similar between field-operated cells and OCV RHC ASTs, where local thinning and divot-type defects are the primary failure modes. While RHC in air also reproduces these failure modes, it is not aggressive enough to differentiate between different membranemore » types in >1,333 hours (55 days) of testing. Conversely, steady-state OCV tests result in significant ionomer morphology changes and global thinning, which do not replicate field degradation and failure modes. It is inferred that during the OCV RHC AST, the decay of the membrane's mechanical properties is accelerated such that materials can be evaluated in hundreds, instead of thousands, of hours, while replicating the degradation and failure modes of field operation; associated AST protocols are recommended as OCV RHC at 90°C for 500 hours with wet/dry cycle durations of 30s/45s and 2m/2m for automotive and bus operation, respectively.« less

  6. Membrane Accelerated Stress Test Development for Polymer Electrolyte Fuel Cell Durability Validated Using Field and Drive Cycle Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukundan, Rangachary; Baker, Andrew M.; Kusoglu, Ahmet

    A combined chemical/mechanical accelerated stress test (AST) was developed for proton exchange membrane (PEM) fuel cells based on relative humidity cycling (RHC) between dry and saturated gases at open circuit voltage (OCV). Membrane degradation and failure were investigated using scanning electron microscopy and small- and wide-angle X-ray scattering. Changes to membrane thickness, hydrophilic domain spacing, and crystallinity were observed to be most similar between field-operated cells and OCV RHC ASTs, where local thinning and divot-type defects are the primary failure modes. While RHC in air also reproduces these failure modes, it is not aggressive enough to differentiate between different membranemore » types in >1,333 hours (55 days) of testing. Conversely, steady-state OCV tests result in significant ionomer morphology changes and global thinning, which do not replicate field degradation and failure modes. It is inferred that during the OCV RHC AST, the decay of the membrane's mechanical properties is accelerated such that materials can be evaluated in hundreds, instead of thousands, of hours, while replicating the degradation and failure modes of field operation; associated AST protocols are recommended as OCV RHC at 90°C for 500 hours with wet/dry cycle durations of 30s/45s and 2m/2m for automotive and bus operation, respectively.« less

  7. 27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. AERIAL VIEW OF ARVFS FIELD TEST SITE AS IT LOOKED IN 1983. OBLIQUE VIEW FACING EAST. BUNKER IS IN FOREGROUND, PROTECTIVE SHED FOR WFRP AT TOP OF IMAGE. INEL PHOTO NUMBER 83-574-12-1, TAKEN IN 1983. PHOTOGRAPHER: ROMERO. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  8. The applicability of a computer model for predicting head injury incurred during actual motor vehicle collisions.

    PubMed

    Moran, Stephan G; Key, Jason S; McGwin, Gerald; Keeley, Jason W; Davidson, James S; Rue, Loring W

    2004-07-01

    Head injury is a significant cause of both morbidity and mortality. Motor vehicle collisions (MVCs) are the most common source of head injury in the United States. No studies have conclusively determined the applicability of computer models for accurate prediction of head injuries sustained in actual MVCs. This study sought to determine the applicability of such models for predicting head injuries sustained by MVC occupants. The Crash Injury Research and Engineering Network (CIREN) database was queried for restrained drivers who sustained a head injury. These collisions were modeled using occupant dynamic modeling (MADYMO) software, and head injury scores were generated. The computer-generated head injury scores then were evaluated with respect to the actual head injuries sustained by the occupants to determine the applicability of MADYMO computer modeling for predicting head injury. Five occupants meeting the selection criteria for the study were selected from the CIREN database. The head injury scores generated by MADYMO were lower than expected given the actual injuries sustained. In only one case did the computer analysis predict a head injury of a severity similar to that actually sustained by the occupant. Although computer modeling accurately simulates experimental crash tests, it may not be applicable for predicting head injury in actual MVCs. Many complicating factors surrounding actual MVCs make accurate computer modeling difficult. Future modeling efforts should consider variables such as age of the occupant and should account for a wider variety of crash scenarios.

  9. 7 CFR 400.51 - Availability of actual production history program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Availability of actual production history program. 400.51 Section 400.51 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP... History § 400.51 Availability of actual production history program. An Actual Production History (APH...

  10. 7 CFR 400.51 - Availability of actual production history program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 6 2011-01-01 2011-01-01 false Availability of actual production history program. 400.51 Section 400.51 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP... History § 400.51 Availability of actual production history program. An Actual Production History (APH...

  11. 7 CFR 400.51 - Availability of actual production history program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 6 2012-01-01 2012-01-01 false Availability of actual production history program. 400.51 Section 400.51 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP... History § 400.51 Availability of actual production history program. An Actual Production History (APH...

  12. 7 CFR 400.51 - Availability of actual production history program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 6 2014-01-01 2014-01-01 false Availability of actual production history program. 400.51 Section 400.51 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP... History § 400.51 Availability of actual production history program. An Actual Production History (APH...

  13. 7 CFR 400.51 - Availability of actual production history program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 6 2013-01-01 2013-01-01 false Availability of actual production history program. 400.51 Section 400.51 Agriculture Regulations of the Department of Agriculture (Continued) FEDERAL CROP... History § 400.51 Availability of actual production history program. An Actual Production History (APH...

  14. Phase I interim report : automotive collision avoidance system field operational test

    DOT National Transportation Integrated Search

    2002-05-30

    In June of 1999, the National Highway Traffic Safety Administration entered into a cooperative research agreement with General Motors to advance the state-of-the-art of rear-end collision warning technology and conduct a field operational test of a f...

  15. Baseline Field Testing of BB-2590 Lithium-Ion Batteries using an iRobot FasTac 510 Robot

    DTIC Science & Technology

    2010-09-17

    No. 21320 Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot FasTac 510 Robot U.S. Army Tank...SEP 2010 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an iRobot...COVERED (From - To) Baseline Field Testing of BB-2590 Lithium - Ion Batteries using an 4. TITLE AND SUBTITLE iRobot FasTac 510 Robot 5a. CONTRACT

  16. The Self-Actualization of Polk Community College Students.

    ERIC Educational Resources Information Center

    Pearsall, Howard E.; Thompson, Paul V., Jr.

    This article investigates the concept of self-actualization introduced by Abraham Maslow (1954). A summary of Maslow's Needs Hierarchy, along with a description of the characteristics of the self-actualized person, is presented. An analysis of humanistic education reveals it has much to offer as a means of promoting the principles of…

  17. A Preliminary Field Test of an Employee Work Passion Model

    ERIC Educational Resources Information Center

    Zigarmi, Drea; Nimon, Kim; Houson, Dobie; Witt, David; Diehl, Jim

    2011-01-01

    Four dimensions of a process model for the formulation of employee work passion, derived from Zigarmi, Nimon, Houson, Witt, and Diehl (2009), were tested in a field setting. A total of 447 employees completed questionnaires that assessed the internal elements of the model in a corporate work environment. Data from the measurements of work affect,…

  18. Electronic intermodal supply chain manifest ITS field operational test evaluation plan

    DOT National Transportation Integrated Search

    2000-09-25

    This document is an evaluation plan for a field operational test (FOT) that is based at O'Hare International Airport in Chicago and which will focus on the air cargo component of intermodal freight movements. The objectives of the FOT are to develop,...

  19. Evaluation of anthropometric, physiological, and skill-related tests for talent identification in female field hockey.

    PubMed

    Keogh, Justin W L; Weber, Clare L; Dalton, Carl T

    2003-06-01

    The purpose of the present study was to develop an effective testing battery for female field hockey by using anthropometric, physiological, and skill-related tests to distinguish between regional representative (Rep, n = 35) and local club level (Club, n = 39) female field hockey players. Rep players were significantly leaner and recorded faster times for the 10-m and 40-m sprints as well as the Illinois Agility Run (with and without dribbling a hockey ball). Rep players also had greater aerobic and lower body muscular power and were more accurate in the shooting accuracy test, p < 0.05. No significant differences between groups were evident for height, body mass, speed decrement in 6 x 40-m repeated sprints, handgrip strength, or pushing speed. These results indicate that %BF, sprinting speed, agility, dribbling control, aerobic and muscular power, and shooting accuracy can distinguish between female field hockey players of varying standards. Therefore talent identification programs for female field hockey should include assessments of these physical parameters.

  20. Field spectrometer (S191H) preprocessor tape quality test program design document

    NASA Technical Reports Server (NTRS)

    Campbell, H. M.

    1976-01-01

    Program QA191H performs quality assurance tests on field spectrometer data recorded on 9-track magnetic tape. The quality testing involves the comparison of key housekeeping and data parameters with historic and predetermined tolerance limits. Samples of key parameters are processed during the calibration period and wavelength cal period, and the results are printed out and recorded on an historical file tape.

  1. Estimation of the level of anxiety in rats: differences in results of open-field test, elevated plus-maze test, and Vogel's conflict test.

    PubMed

    Sudakov, S K; Nazarova, G A; Alekseeva, E V; Bashkatova, V G

    2013-07-01

    We compared individual anxiety assessed by three standard tests, open-field test, elevated plus-maze test, and Vogel conflict drinking test, in the same animals. No significant correlations between the main anxiety parameters were found in these three experimental models. Groups of animals with high and low anxiety rats were formed by a single parameter and subsequent selection of two extreme groups (10%). It was found that none of the tests could be used for reliable estimation of individual anxiety in rats. The individual anxiety level with high degree of confidence was determined in high-anxiety and low-anxiety rats demonstrating behavioral parameters above and below the mean values in all tests used. Therefore, several tests should be used for evaluation of the individual anxiety or sensitivity to emotional stress.

  2. Development and field testing of a smartphone "App" for tinnitus management.

    PubMed

    Henry, James A; Thielman, Emily; Zaugg, Tara; Kaelin, Christine; Choma, Christie; Chang, Bill; Hahn, Shira; Fuller, Bret

    2017-10-01

    This study's objective was to develop and test a smartphone app that supports learning and using coping skills for managing tinnitus. The app's content was based on coping skills that are taught as a part of progressive tinnitus management (PTM). The study involved three phases: (1) develop a prototype app and conduct usability testing; (2) conduct two focus groups to obtain initial feedback from individuals representing potential users; and (3) conduct a field study to evaluate the app, with three successive groups of participants. Participants were adults with bothersome tinnitus. For Phase 2, two focus groups were attended by a total of 17 participants. Phase 3 involved three consecutive rounds of participants: five from the focus groups followed by two rounds with 10 participants each who had not seen the app previously. In both the focus groups and field studies, participants responded favourably to the content. Certain features, however, were deemed too complex. Completion of this project resulted in the development and testing of the delivery of PTM coping skills via a smartphone app. This new approach has the potential to improve access to coping skills for those with bothersome tinnitus.

  3. Do subjective measures of attention and memory predict actual performance? Metacognition in older couples.

    PubMed

    Volz-Sidiropoulou, Eftychia; Gauggel, Siegfried

    2012-06-01

    Older individuals who recognize their cognitive difficulties are more likely to adjust their everyday life to their actual cognitive functioning, particularly when they are able to estimate their abilities accurately. We assessed self- and spouse-ratings of memory and attention difficulties in everyday life of healthy, older individuals and compared them with the respective test performance. Eighty-four older individuals (women's age, M = 67.4 years, SD = 5.2; men's age, M = 68.5 years, SD = 4.9) completed both the self and the spouse versions of the Attention Deficit Questionnaire and the Everyday Memory Questionnaire and completed two neuropsychological tests. Using the residual score approach, subjective metacognitive measures of memory and attention were created and compared with actual test performance. Significant associations between subjective and objective scores were found only for men and only for episodic memory measures. Men who underreported memory difficulties performed more poorly; men who overreported memory difficulties performed better. Men's recognition performance was best predicted by subjective measures (R² = .25), followed by delayed recall (R² = .14) and forgetting rate (R² = .13). The results indicate gender-specific differences in metacognitive accuracy and predictive validity of subjective ratings. PsycINFO Database Record (c) 2012 APA, all rights reserved

  4. Examination of the Structural Response of the Orion European Service Module to Reverberant and Direct Field Acoustic Testing

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Hughes, William O.; Larko, Jeffrey M.; Bittinger, Samantha A.; Le-Plenier, Cyprien; Fogt, Vincent A.; Ngan, Ivan; Thirkettle, Anthony C.; Skinner, Mitch; Larkin, Paul

    2017-01-01

    The NASA Orion Multi-Purpose Crew Vehicle (MPCV), comprised of the Service Module, the Crew Module, and the Launch Abort System, is the next generation human spacecraft designed and built for deep space exploration. Orion will launch on NASAs new heavy-lift rocket, the Space Launch System. The European Space Agency (ESA) is responsible for providing the propulsion sub-assembly of the Service Module to NASA, called the European Service Module (ESM). The ESM is being designed and built by Airbus Safran Launchers for ESA. Traditionally, NASA has utilized reverberant acoustic testing for qualification of spaceflight hardware. The ESM Structural Test Article (E-STA) was tested at the NASA Plum Brook Stations (PBS) Reverberant Acoustic Test Facility in April-May 2016. However, Orion is evaluating an alternative acoustic test method, using direct field acoustic excitation, for the MPCVs Service Module and Crew Module. Lockheed Martin is responsible for the Orion proof-of-concept direct field acoustic test program. The E-STA was exposed to direct field acoustic testing at NASA PBS in February 2017. This paper compares the dynamic response of the E-STA structure and its components to both the reverberant and direct field acoustic test excitations. Advantages and disadvantages of direct field acoustic test excitation method are discussed.

  5. Measurement of physical performance by field tests in programs of cardiac rehabilitation: a systematic review and meta-analysis.

    PubMed

    Travensolo, Cristiane; Goessler, Karla; Poton, Roberto; Pinto, Roberta Ramos; Polito, Marcos Doederlein

    2018-04-13

    The literature concerning the effects of cardiac rehabilitation (CR) on field tests results is inconsistent. To perform a systematic review with meta-analysis on field tests results after programs of CR. Studies published in PubMed and Web of Science databases until May 2016 were analyzed. The standard difference in means correct by bias (Hedges' g) was used as effect size (g) to measure que amount of modifications in performance of field tests after CR period. Potential differences between subgroups were analyzed by Q-test based on ANOVA. Fifteen studies published between 1996 e 2016 were included in the review, 932 patients and age ranged 54,4 - 75,3 years old. Fourteen studies used the six-minutes walking test to evaluate the exercise capacity and one study used the Shuttle Walk Test. The random Hedges's g was 0.617 (P<0.001), representing a drop of 20% in the performance of field test after CR. The meta-regression showed significantly association (P=0.01) to aerobic exercise duration, i.e., for each 1-min increase in aerobic exercise duration, there is a 0.02 increase in effect size for performance in the field test. Field tests can detect physical modification after CR, and the large duration of aerobic exercise during CR was associated with a better result. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. ADX: a high field, high power density, Advanced Divertor test eXperiment

    NASA Astrophysics Data System (ADS)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Shiraiwa, S.; Terry, J.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; ADX Team

    2014-10-01

    The MIT PSFC and collaborators are proposing an advanced divertor experiment (ADX) - a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to FNSF/DEMO. This high field (6.5 tesla, 1.5 MA), high power density (P/S ~ 1.5 MW/m2) facility would utilize Alcator magnet technology to test innovative divertor concepts for next-step DT fusion devices (FNSF, DEMO) at reactor-level boundary plasma pressures and parallel heat flux densities while producing high performance core plasma conditions. The experimental platform would also test advanced lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators and wave physics at the plasma densities and magnetic field strengths of a DEMO, with the unique ability to deploy launcher structures both on the low-magnetic-field side and the high-field side - a location where energetic plasma-material interactions can be controlled and wave physics is most favorable for efficient current drive, heating and flow drive. This innovative experiment would perform plasma science and technology R&D necessary to inform the conceptual development and accelerate the readiness-for-deployment of FNSF/DEMO - in a timely manner, on a cost-effective research platform. Supported by DE-FC02-99ER54512.

  7. Impact of plant-soil feedback on plant traits at field scale, testing the use of UAV-based optical sensors

    NASA Astrophysics Data System (ADS)

    De Deyn, Gerlinde B.; van der Meij, Bob; Barel, Janna M.; Suomalainen, Juha; Kooistra, Lammert

    2017-04-01

    Plant responses to biotic and abiotic legacies left in soil by preceding plants is known as plant-soil feedback (PSF). PSF is an important mechanism to explain plant community dynamics and plant performance in natural and agricultural systems. However, most PSF studies are short-term and small-scale due to practical constraints for field scale quantification of PSF effects, yet field experiments are warranted to asses actual PSF effects under less controlled conditions. Here we used Unmanned Aerial Vehicle (UAV)-based optical sensors to test whether PSF effects on plant traits can be quantified remotely. We established a randomized agro-ecological field experiment in which six different cover crop species and species combinations from three different plant families (Poaceae, Fabaceae, Brassicaceae) were grown. The feedback effects on plant traits were tested in oat (Avena sativa) by quantifying the cover crop legacy effects on key plant traits: height, fresh biomass, nitrogen content and leaf chlorophyll content. Prior to destructive sampling, hyperspectral data was acquired and used for calibration and independent validation of regression models to retrieve plant traits from optical data. Subsequently, for each trait the model with highest precision and accuracy was selected. We used the hyperspectral analyses to predict the directly measured plant height (RMSE= 5.12 cm, R2= 0.79), chlorophyll content (RMSE= 0.11 g m-2, R2= 0.80), N-content (RMSE= 1.94 g m-2, R2= 0.68), and fresh biomass (RMSE= 0.72 kg m-2, R2=0.56). Overall the PSF effects of the different cover crop treatments based on the remote sensing data matched the results based on in situ measurements. The average oat canopy was tallest and its leaf chlorophyll content highest in response to legacy of Vicia sativa monocultures (100 cm, 0.95 g m-2, respectively) and in mixture with Raphanus sativus (100 cm, 1.09 g m-2, respectively), while the lowest values (76 cm, 0.41 g m-2, respectively) were found in

  8. Actual waste demonstration of the nitric-glycolic flowsheet for sludge batch 9 qualification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newell, D.; Pareizs, J.; Martino, C.

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch is processable. Based on the results of this actual-waste qualification and previous simulant studies, SRNL recommends implementation of the nitric-glycolic acid flowsheet in DWPF. Other recommendations resulting from this demonstration are reported in section 5.0.

  9. Nondestructive testing and characterization of residual stress field using an ultrasonic method

    NASA Astrophysics Data System (ADS)

    Song, Wentao; Xu, Chunguang; Pan, Qinxue; Song, Jianfeng

    2016-03-01

    To address the difficulty in testing and calibrating the stress gradient in the depth direction of mechanical components, a new technology of nondestructive testing and characterization of the residual stress gradient field by ultrasonic method is proposed based on acoustoelasticity theory. By carrying out theoretical analysis, the sensitivity coefficients of different types of ultrasonic are obtained by taking the low carbon steel(12%C) as a research object. By fixing the interval distance between sending and receiving transducers, the mathematical expressions of the change of stress and the variation of time are established. To design one sending-one receiving and oblique incidence ultrasonic detection probes, according to Snell law, the critically refracted longitudinal wave (LCR wave) is excited at a certain depth of the fixed distance of the tested components. Then, the relationship between the depth of LCR wave detection and the center frequency of the probe in Q235 steel is obtained through experimental study. To detect the stress gradient in the depth direction, a stress gradient LCR wave detection model is established, through which the stress gradient formula is derived by the relationship between center frequency and detecting depth. A C-shaped stress specimen of Q235 steel is designed to conduct stress loading tests, and the stress is measured with the five group probes at different center frequencies. The accuracy of ultrasonic testing is verified by X-ray stress analyzer. The stress value of each specific depth is calculated using the stress gradient formula. Accordingly, the ultrasonic characterization of residual stress field is realized. Characterization results show that the stress gradient distribution is consistent with the simulation in ANSYS. The new technology can be widely applied in the detection of the residual stress gradient field caused by mechanical processing, such as welding and shot peening.

  10. Field monitoring of static, dynamic, and statnamic pile loading tests using fibre Bragg grating strain sensors

    NASA Astrophysics Data System (ADS)

    Li, Jin; Correia, Ricardo P.; Chehura, Edmon; Staines, Stephen; James, Stephen W.; Tatam, Ralph; Butcher, Antony P.; Fuentes, Raul

    2009-10-01

    Pile loading test plays an important role in the field of piling engineering. In order to gain further insight into the load transfer mechanism, strain gauges are often used to measure local strains along the piles. This paper reports a case whereby FBG strain sensors was employed in a field trial conducted on three different types of pile loading tests in a glacial till. The instrumentation systems were configured to suit the specific characteristic of each type of test. Typical test results are presented. The great potential of using FBG sensors for pile testing is shown.

  11. Comparison of Field and Laboratory-Based Tests for Behavioral Response of Aedes aegypti (Diptera: Culicidae) to Repellents.

    PubMed

    Sathantriphop, Sunaiyana; Kongmee, Monthathip; Tainchum, Krajana; Suwansirisilp, Kornwika; Sanguanpong, Unchalee; Bangs, Michael J; Chareonviriyaphap, Theeraphap

    2015-12-01

    The repellent and irritant effects of three essential oils-clove, hairy basil, and sweet basil-were compared using an excito-repellency test system against an insecticide-resistant strain of Aedes aegypti (L.) females from Pu Teuy, Kanchanaburi Province. DEET was used as the comparison standard compound. Tests were conducted under field and controlled laboratory conditions. The most marked repellent effect (spatial noncontact assay) among the three test essential oils was exhibited by sweet basil, Ocimum basilicum L. (53.8% escaped mosquitoes in 30-min exposure period) under laboratory conditions while hairy basil, Ocimum americanum L. and clove, Syzygium aromaticum (L.) Merill et. L.M. Perry from laboratory tests and sweet basil from field tests were the least effective as repellents (0-14%). In contrast, the contact assays measuring combined irritancy (excitation) and repellency effects found the best contact irritant response to hairy basil and DEET in field tests, whereas all others in laboratory and field were relatively ineffective in stimulating mosquitoes to move out the test chambers (0-5.5%). All three essential oils demonstrated significant differences in behavioral responses between field and laboratory conditions, whereas there was no significant difference in contact and noncontact assays for DEET between the two test conditions (P > 0.05). © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Workplace field testing of the pressure drop of particulate respirators using welding fumes.

    PubMed

    Cho, Hyun-Woo; Yoon, Chung-Sik

    2012-10-01

    In a previous study, we concluded that respirator testing with a sodium chloride aerosol gave a conservative estimate of filter penetration for welding fume aerosols. A rapid increase in the pressure drop (PD) of some respirators was observed as fumes accumulated on the filters. The present study evaluated particulate respirator PD based on workplace field tests. A field PD tester was designed and validated using the TSI 8130 Automatic Filter Tester, designed in compliance with National Institute for Occupational and Safety and Health regulation 42 CFR part 84. Three models (two replaceable dual-type filters and one replaceable single-type filter) were evaluated against CO(2) gas arc welding on mild steel in confined booths in the workplace. Field tests were performed under four airborne concentrations (27.5, 15.4, 7.9, and 2.1 mg m(-3)). The mass concentration was measured by the gravimetric method, and number concentration was monitored using P-Trak (Model 8525, TSI, USA). Additionally, photos and scanning electron microscopy-energy dispersive X-ray spectroscopy were used to visualize and analyze the composition of welding fumes trapped in the filters. The field PD tester showed no significant difference compared with the TSI tester. There was no significant difference in the initial PD between laboratory and field results. The PD increased as a function of fume load on the respirator filters for all tested models. The increasing PD trend differed by models, and PD increased rapidly at high concentrations because greater amount of fumes accumulated on the filters in a given time. The increase in PD as a function of fume load on the filters showed a similar pattern as fume load varied for a particular model, but different patterns were observed for different models. Images and elemental analyses of fumes trapped on the respirator filters showed that most welding fumes were trapped within the first layer, outer web cover, and second layer, in order, while no fumes

  13. Field test of a new Australian method of rangeland monitoring

    Treesearch

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...

  14. Near-field Testing of the 15-meter Model of the Hoop Column Antenna

    NASA Technical Reports Server (NTRS)

    Hoover, J.; Kefauver, N.; Cencich, T.; Osborn, J.; Osmanski, J.

    1986-01-01

    The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are documented. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 1) covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas. This volume discusses the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, gives the test program outline, and gives a synopsis of antenna electromagnetic performance. Three techniques for measuring surface mechanical tolerances were used (theodolites, metric cameras, and near-field phase), but only the near-field phase approach is included. The report also includes an error analysis. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume 3 of this report, and for all other feeds in Volume 2.

  15. Understanding spatio-temporal strategies of adult zebrafish exploration in the open field test.

    PubMed

    Stewart, Adam Michael; Gaikwad, Siddharth; Kyzar, Evan; Kalueff, Allan V

    2012-04-27

    Zebrafish (Danio rerio) are emerging as a useful model organism for neuroscience research. Mounting evidence suggests that various traditional rodent paradigms may be adapted for testing zebrafish behavior. The open field test is a popular rodent test of novelty exploration, recently applied to zebrafish research. To better understand fish novelty behavior, we exposed adult zebrafish to two different open field arenas for 30 min, assessing the amount and temporal patterning of their exploration. While (similar to rodents) zebrafish scale their locomotory activity depending on the size of the tank, the temporal patterning of their activity was independent of arena size. These observations strikingly parallel similar rodent behaviors, suggesting that spatio-temporal strategies of animal exploration may be evolutionarily conserved across vertebrate species. In addition, we found interesting oscillations in zebrafish exploration, with the per-minute distribution of their horizontal activity demonstrating sinusoidal-like patterns. While such patterning is not reported for rodents and other higher vertebrates, a nonlinear regression analysis confirmed the oscillation patterning of all assessed zebrafish behavioral endpoints in both open field arenas, revealing a potentially important aspect of novelty exploration in lower vertebrates. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Narrow-field-of-view bathymetrical lidar: theory and field test

    NASA Astrophysics Data System (ADS)

    Feygels, Viktor I.; Wright, C. Wayne; Kopilevich, Yuri I.; Surkov, Alexey I.

    2003-11-01

    The purpose of this paper is to derive a reliable theory to predict the performance of a narrow-FOV bathymetric lidar. A fundamental discrepancy between the theoretical estimate and experimental results was the inspiration for the work presented here Meeting oceanographic mapping requirements is a critically important goal for littoral laser bathymetry. In contrast to traditional airborne lidar system which are optimized for recovering signals from the deepest possible waters , the above challenge may be met with a radical narrowing to the lidar transmit beam and receiver field of view (FOV) employed in EAARL (Experimental Advanced Airborne Research Lidar, NASA). In this paper we discuss theoretical analysis carried out on the basis of a sophisticated "multiple-forward scattering and single-backscattering model" for lidar return signals allows a quantitative estimation of the advantages of a narrow-FOV system over traditional bathymetric lidars (SHOALS-400, SHOALS-100, LADS Mk II) when used in clear shallow-water cases. Some of those advantages are: ¸ Increase in bottom definition (or reduced false-alarm probability) due to the enhanced contrast of the bottom return over the background backscatter from the water column, ¸ Enhancement in depth measurement accuracy resulting from narrower bottom return pulse width, ¸ Reduction of post-surface return effects in the lidar photo-multiplier detector due to a more rapid decay of water column backscatter, ¸ Greatly improved rejection of ambient light permitting lidar operations in all zenith sun angles and flight directions. The model computations make it possible to estimate the maximal operational depth for the system under consideration by the implementation of statistical theory of detectability. These computations depend on the prevailing seawater optical properties and lidar parameters. The theoretical predictions are compared with results obtained in the field test of the EAARL system carried out in Florida Keys

  17. To Be or Want to Be: Disentangling the Role of Actual versus Ideal Self in Implicit Self-Esteem

    PubMed Central

    De Houwer, Jan; De Raedt, Rudi

    2014-01-01

    A growing body of work suggests that both depressed and non-depressed individuals display implicit positivity towards the self. In the current study, we examined whether this positivity can be underpinned by two qualitatively distinct propositions related to actual (‘I am good’) or ideal (‘I want to be good’) self-esteem. Dysphoric and non-dysphoric participants completed a self-esteem Implicit Association Test (IAT) as well an Implicit Relational Assessment Procedure (IRAP) targeting their actual self-esteem and an IRAP targeting ideal self-esteem. Both groups demonstrated similar and positive IAT effects. A more complex picture emerged with regard to the IRAP effects. Whereas non-dysphorics did not differ in their actual and ideal self-esteem, their dysphoric counterparts demonstrated lower actual than ideal self-esteem. Our results suggest that closer attention to the role of propositional processes in implicit measures may unlock novel insight into the relationship between implicit self-esteem and depression. PMID:25268889

  18. Demonstration and Field Test of airjacket technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faulkner, D.; Fisk, W.J.; Gadgil, A.J.

    1998-06-01

    There are approximately 600,000 paint spray workers in the United States applying paints and coatings with some type of sprayer. Approximately 5% of these spray workers are in the South Coast Air Quality Management District (SCAQMD). These spray workers apply paints or other coatings to products such as bridges, houses, automobiles, wood and metal furniture, and other consumer and industrial products. The materials being sprayed include exterior and interior paints, lacquers, primers, shellacs, stains and varnishes. Our experimental findings indicate that the Airjacket does not significantly reduce the exposure of spray workers to paint fumes during HVLP spraying. The differencemore » between ideal and actual spray paint procedures influence the mechanisms driving spray workers exposures to paint fumes and influence the viability of the Airjacket technology. In the ideal procedure, for which the Airjacket was conceived, the spray worker's exposure to paint fumes is due largely to the formation of a recirculating eddy between the spray worker and the object painted. The Airjacket ejects air to diminish and ventilate this eddy. In actual practice, exposures may result largely from directing paint upstream and from the bounce-back of the air/paint jet of the object being painted. The Airjacket, would not be expected to dramatically reduce exposures to paint fumes when the paint is not directed downstream or when the bounce-back of paint on the object creates a cloud of paint aerosols around the spray worker.« less

  19. Implementing the Mars Science Laboratory Terminal Descent Sensor Field Test Campaign

    NASA Technical Reports Server (NTRS)

    Montgomery, James F.; Bodie, James H.; Brown, Joseph D.; Chen, Allen; Chen, Curtis W.; Essmiller, John C.; Fisher, Charles D.; Goldberg, Hannah R.; Lee, Steven W.; Shaffer, Scott J.

    2012-01-01

    The Mars Science Laboratory (MSL) will deliver a 900 kg rover to the surface of Mars in August 2012. MSL will utilize a new pulse-Doppler landing radar, the Terminal Descent Sensor (TDS). The TDS employs six narrow-beam antennas to provide unprecedented slant range and velocity performance at Mars to enable soft touchdown of the MSL rover using a unique sky crane Entry, De-scent, and Landing (EDL) technique. Prior to use on MSL, the TDS was put through a rigorous verification and validation (V&V) process. A key element of this V&V was operating the TDS over a series of field tests, using flight-like profiles expected during the descent and landing of MSL over Mars-like terrain on Earth. Limits of TDS performance were characterized with additional testing meant to stress operational modes outside of the expected EDL flight profiles. The flight envelope over which the TDS must operate on Mars encompasses such a large range of altitudes and velocities that a variety of venues were neces-sary to cover the test space. These venues included an F/A-18 high performance aircraft, a Eurocopter AS350 AStar helicopter and 100-meter tall Echo Towers at the China Lake Naval Air Warfare Center. Testing was carried out over a five year period from July 2006 to June 2011. TDS performance was shown, in gen-eral, to be excellent over all venues. This paper describes the planning, design, and implementation of the field test campaign plus results and lessons learned.

  20. Electrodermal responses to implied versus actual violence on television.

    PubMed

    Kalamas, A D; Gruber, M L

    1998-01-01

    The electrodermal response (EDR) of children watching a violent show was measured. Particular attention was paid to the type of violence (actual or implied) that prompted an EDR. In addition, the impact of the auditory component (sounds associated with violence) of the show was evaluated. Implied violent stimuli, such as the villain's face, elicited the strongest EDR. The elements that elicited the weakest responses were the actual violent stimuli, such as stabbing. The background noise and voices of the sound track enhanced the total number of EDRs. The results suggest that implied violence may elicit more fear (as measured by EDRs) than actual violence does and that sounds alone contribute significantly to the emotional response to television violence. One should not, therefore, categorically assume that a show with mostly actual violence evokes less fear than one with mostly implied violence.

  1. Perceived Motor Competence Differs From Actual Performance in 8-Year-Old Neonatal ECMO Survivors.

    PubMed

    Toussaint, Leontien C C; van der Cammen-van Zijp, Monique H M; Janssen, Anjo J; Tibboel, Dick; van Heijst, Arno F; IJsselstijn, Hanneke

    2016-03-01

    To assess perceived motor competence, social competence, self-worth, health-related quality of life, and actual motor performancein 8-year-old survivors of neonatal extracorporeal membrane oxygenation (ECMO). In a prospective nationwide study, 135 children completed the extended version of the "athletic competence" domain of the Self Perception Profile for Children (SPPC) called the m-CBSK (Motor supplement of the Competentie BelevingsSchaal voor Kinderen) to assess perceived motor competence, the SPPC, and the Pediatric Quality of Life Inventory (PedsQL), andwere tested with the Movement Assessment Battery for Children. SD scores (SDS) were used to compare with the norm. The mean (SD) SDS for perceived motor competence, social competence, and self-worth were all significantly higher than the norm: 0.18 (0.94), P = .03; 0.35 (1.03), P < .001; and 0.32 (1.08), P < .001, respectively. The total PedsQL score was significantly below the norm: mean (SD) SDS: -1.26 (1.53), P < .001. Twenty-two percent of children had actual motor problems. The SDS m-CBSK and actual motor performance did not correlate (r = 0.12; P = .17). The SDS m-CBSK significantly correlated with the athletic competence domain of the SPPC (r = 0.63; P < .001). Eight-year-old ECMO survivors feel satisfied with their motor- and social competence, despite impaired PedsQL scores and motor problems. Because motor problems in ECMO survivorsdeteriorate throughout childhood, clinicians should be aware that these patients may tend to "overrate" their actual motor performance. Education andstrict monitoring of actual motor performanceare important to enable timelyintervention. Copyright © 2016 by the American Academy of Pediatrics.

  2. Self-Actualization and the Human Tendency for Varied Experience

    ERIC Educational Resources Information Center

    Schwartz, Marilyn M.; Gaines, Lawrence S.

    1974-01-01

    Examines the hypothesis that a significant correlate of self-actualization may be the subjective expression of the tendency towards novelty experiencing and examines the interaction of self-actualization level and specific components of the novelty experiencing construct. (Author/RC)

  3. Paradigms of Evaluation in Natural Language Processing: Field Linguistics for Glass Box Testing

    ERIC Educational Resources Information Center

    Cohen, Kevin Bretonnel

    2010-01-01

    Although software testing has been well-studied in computer science, it has received little attention in natural language processing. Nonetheless, a fully developed methodology for glass box evaluation and testing of language processing applications already exists in the field methods of descriptive linguistics. This work lays out a number of…

  4. U.S. Army RDECOM-ARDEC's results of the TG-53 experiment and field test

    NASA Astrophysics Data System (ADS)

    Desai, Sachi V.; Morcos, Amir

    2009-05-01

    Herein is described the U.S. Army RDECOM-ARDEC's purpose and series of activities conducted at the 2008 NATO SET-093 TG-53 experiment and field test. The overall purpose of the field test as stated by SET-093 panel was to provide a baseline test capable of providing relevant scenarios and data regarding a variety of impulsive generated acoustic events. As organized, the field experiment also allowed the room o study sensor interoperability across multiple platforms and multi-national users via the spider communication framework/reporting structure. This multinational network maintained by the host ETBS with a standardized messaging format with specific goals for each participating organization. ARDEC's role and purpose for the test was to provide situational awareness via the Spider and associated messaging format to the ETBS command center while continuing to gather unique acoustic data from various vantage points. ARDEC had several deliverables for the TG-53 field experiment derived from the mission and spirit of the field test. The most relevant deliverable was to demonstrate sensor interoperability via the Spider network and provide situational awareness by describing the said mortar/artillery events. The second purpose revolved around a relevant environment algorithm validation of the muzzle blast discrimination for future UGS transition in particular the UTAMS II. The algorithm validation information remained internal to the specific data acquisition system and not broadcasted out on the Spider network. The TG-53 field experiments provided the added opportunity to further test and refine the algorithm based on the discrete wavelet transform (DWT) and multiresolution analysis. These techniques are used to classify and reliably discriminates between launch and impact artillery and/or mortar events via acoustic signals produced during detonation. Distinct characteristics are found within the acoustic signatures since impact events emphasize concussive and

  5. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 3 Full-scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe

    2007-05-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project is conducting pilot- and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB cofired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems to be tested. IPL, an AES company, provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Degussa Corporation is providing the TMT-15 additive and technical support to the test program as cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive

  6. Consistency across Repeated Eyewitness Interviews: Contrasting Police Detectives’ Beliefs with Actual Eyewitness Performance

    PubMed Central

    Krix, Alana C.; Sauerland, Melanie; Lorei, Clemens; Rispens, Imke

    2015-01-01

    In the legal system, inconsistencies in eyewitness accounts are often used to discredit witnesses’ credibility. This is at odds with research findings showing that witnesses frequently report reminiscent details (details previously unrecalled) at an accuracy rate that is nearly as high as for consistently recalled information. The present study sought to put the validity of beliefs about recall consistency to a test by directly comparing them with actual memory performance in two recall attempts. All participants watched a film of a staged theft. Subsequently, the memory group (N = 84) provided one statement immediately after the film (either with the Self-Administered Interview or free recall) and one after a one-week delay. The estimation group (N = 81) consisting of experienced police detectives estimated the recall performance of the memory group. The results showed that actual recall performance was consistently underestimated. Also, a sharp decline of memory performance between recall attempts was assumed by the estimation group whereas actual accuracy remained stable. While reminiscent details were almost as accurate as consistent details, they were estimated to be much less accurate than consistent information and as inaccurate as direct contradictions. The police detectives expressed a great concern that reminiscence was the result of suggestive external influences. In conclusion, it seems that experienced police detectives hold many implicit beliefs about recall consistency that do not correspond with actual recall performance. Recommendations for police trainings are provided. These aim at fostering a differentiated view on eyewitness performance and the inclusion of more comprehensive classes on human memory structure. PMID:25695428

  7. Consistency across repeated eyewitness interviews: contrasting police detectives' beliefs with actual eyewitness performance.

    PubMed

    Krix, Alana C; Sauerland, Melanie; Lorei, Clemens; Rispens, Imke

    2015-01-01

    In the legal system, inconsistencies in eyewitness accounts are often used to discredit witnesses' credibility. This is at odds with research findings showing that witnesses frequently report reminiscent details (details previously unrecalled) at an accuracy rate that is nearly as high as for consistently recalled information. The present study sought to put the validity of beliefs about recall consistency to a test by directly comparing them with actual memory performance in two recall attempts. All participants watched a film of a staged theft. Subsequently, the memory group (N = 84) provided one statement immediately after the film (either with the Self-Administered Interview or free recall) and one after a one-week delay. The estimation group (N = 81) consisting of experienced police detectives estimated the recall performance of the memory group. The results showed that actual recall performance was consistently underestimated. Also, a sharp decline of memory performance between recall attempts was assumed by the estimation group whereas actual accuracy remained stable. While reminiscent details were almost as accurate as consistent details, they were estimated to be much less accurate than consistent information and as inaccurate as direct contradictions. The police detectives expressed a great concern that reminiscence was the result of suggestive external influences. In conclusion, it seems that experienced police detectives hold many implicit beliefs about recall consistency that do not correspond with actual recall performance. Recommendations for police trainings are provided. These aim at fostering a differentiated view on eyewitness performance and the inclusion of more comprehensive classes on human memory structure.

  8. Predicting occupational personality test scores.

    PubMed

    Furnham, A; Drakeley, R

    2000-01-01

    The relationship between students' actual test scores and their self-estimated scores on the Hogan Personality Inventory (HPI; R. Hogan & J. Hogan, 1992), an omnibus personality questionnaire, was examined. Despite being given descriptive statistics and explanations of each of the dimensions measured, the students tended to overestimate their scores; yet all correlations between actual and estimated scores were positive and significant. Correlations between self-estimates and actual test scores were highest for sociability, ambition, and adjustment (r = .62 to r = .67). The results are discussed in terms of employers' use and abuse of personality assessment for job recruitment.

  9. Automated water monitor system field demonstration test report. Volume 2: Technical summary

    NASA Technical Reports Server (NTRS)

    Brooks, R. L.; Jeffers, E. L.; Perreira, J.; Poel, J. D.; Nibley, D.; Nuss, R. H.

    1981-01-01

    The NASA Automatic Water Monitor System was installed in a water reclamation facility to evaluate the technical and cost feasibility of producing high quality reclaimed water. Data gathered during this field demonstration test are reported.

  10. Exploratory rearing: a context- and stress-sensitive behavior recorded in the open-field test.

    PubMed

    Sturman, Oliver; Germain, Pierre-Luc; Bohacek, Johannes

    2018-02-16

    Stressful experiences are linked to anxiety disorders in humans. Similar effects are observed in rodent models, where anxiety is often measured in classic conflict tests such as the open-field test. Spontaneous rearing behavior, in which rodents stand on their hind legs to explore, can also be observed in this test yet is often ignored. We define two forms of rearing, supported rearing (in which the animal rears against the walls of the arena) and unsupported rearing (in which the animal rears without contacting the walls of the arena). Using an automated open-field test, we show that both rearing behaviors appear to be strongly context dependent and show clear sex differences, with females rearing less than males. We show that unsupported rearing is sensitive to acute stress, and is reduced under more averse testing conditions. Repeated testing and handling procedures lead to changes in several parameters over varying test sessions, yet unsupported rearing appears to be rather stable within a given animal. Rearing behaviors could therefore provide an additional measure of anxiety in rodents relevant for behavioral studies, as they appear to be highly sensitive to context and may be used in repeated testing designs.

  11. Influence of movable test section elements configuration on its drag and flow field uniformity at transonic speeds

    NASA Astrophysics Data System (ADS)

    Glazkov, S. A.; Gorbushin, A. R.; Osipova, S. L.; Semenov, A. V.

    2016-10-01

    The report describes the results of flow field experimental research in TsAGI T-128 transonic wind tunnel. During the tests Mach number, stagnation pressure, test section wall perforation ratio, angles between the test section panels and mixing chamber flaps varied. Based on the test results one determined corrections to the free-stream Mach number related to the flow speed difference in the model location and in the zone of static pressure measurement on the test section walls, nonuniformity of the longitudinal velocity component in the model location, optimal position of the movable test section elements to provide flow field uniformity in the test section and minimize the test leg drag.

  12. A petroleum discovery-rate forecast revisited-The problem of field growth

    USGS Publications Warehouse

    Drew, L.J.; Schuenemeyer, J.H.

    1992-01-01

    A forecast of the future rates of discovery of crude oil and natural gas for the 123,027-km2 Miocene/Pliocene trend in the Gulf of Mexico was made in 1980. This forecast was evaluated in 1988 by comparing two sets of data: (1) the actual versus the forecasted number of fields discovered, and (2) the actual versus the forecasted volumes of crude oil and natural gas discovered with the drilling of 1,820 wildcat wells along the trend between January 1, 1977, and December 31, 1985. The forecast specified that this level of drilling would result in the discovery of 217 fields containing 1.78 billion barrels of oil equivalent; however, 238 fields containing 3.57 billion barrels of oil equivalent were actually discovered. This underestimation is attributed to biases introduced by field growth and, to a lesser degree, the artificially low, pre-1970's price of natural gas that prevented many smaller gas fields from being brought into production at the time of their discovery; most of these fields contained less than 50 billion cubic feet of producible natural gas. ?? 1992 Oxford University Press.

  13. The Self-Actualizing Case Method.

    ERIC Educational Resources Information Center

    Gunn, Bruce

    1980-01-01

    Presents a case procedure designed to assist trainees in perfecting their problem-solving skills. Elements of that procedure are the rationale behind this "self-actualizing" case method; the role that the instructor, case leaders, and participants play in its execution; and the closed-loop grading system used for peer evaluation. (CT)

  14. Linguistic Theory and Actual Language.

    ERIC Educational Resources Information Center

    Segerdahl, Par

    1995-01-01

    Examines Noam Chomsky's (1957) discussion of "grammaticalness" and the role of linguistics in the "correct" way of speaking and writing. It is argued that the concern of linguistics with the tools of grammar has resulted in confusion, with the tools becoming mixed up with the actual language, thereby becoming the central…

  15. Evaluation plan : the Branson Travel and Recreational Information Program field operational test

    DOT National Transportation Integrated Search

    1998-02-25

    The Branson Travel and Recreational Information Program (TRIP) is a Field Operational Test (FOT) of Traveler Information Services in Tourism Areas funded through the National Advanced Rural Transportation Systems Program. Over the past ten years, Bra...

  16. Moving from the laboratory to the field: Adding natural environmental conditions to toxicology testing

    EPA Science Inventory

    While laboratory toxicology tests are generally easy to perform, cost effective and readily interpreted, they have been criticized for being unrealistic. In contrast, field tests are considered realistic while producing results that are difficult to interpret and expensive. To ...

  17. Field Test: Results from the One Year Mission

    NASA Technical Reports Server (NTRS)

    Reschke, M. F.; Kozlovskaya, I. B.; Kofman, I. S.; Tomilovskaya, E. S.; Cerisano, J. M.; Rosenberg, M. J. F.; Bloomberg, J. J.; Stenger, M. B.; Lee, S. M. C.; Laurie, S. S.; hide

    2017-01-01

    The One Year Mission was designed to aid in determining the effect that extending the duration on orbit aboard the International Space Station (ISS) would have on a number of biological and physiological systems. Two crewmembers were selected to participate in this endeavor, one U.S. On-Orbit Segment (USOS) astronaut and one Russian cosmonaut. The Neuroscience and Cardiovascular and Vision Laboratories at the Johnson Space Center and the Sensory-Motor and Countermeasures Division within the Institute for Biomedical Problems were selected to investigate vestibular, sensorimotor and cardiovascular function with the two long-duration crewmembers using the established methodology developed for the Field Test (FT).

  18. Field kit and method for testing for the presence of gunshot residue

    DOEpatents

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  19. Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Baxter, Van D.; Abdelaziz, Omar

    2017-03-01

    This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

  20. Taiwanese Parents' Beliefs Regarding Young Children's Art Education and the Actual Art Achievements of Children

    ERIC Educational Resources Information Center

    Hsiao, Ching-Yuan; Pai, Tzu-Chi

    2014-01-01

    The research goal is to ascertain the current beliefs of the parents of preschool children regarding art education in Taiwan. Background factors on the parents were tested to show the differences between the parents' beliefs regarding art education and the actual art achievements of the children. From there, relationships between the beliefs and…

  1. Field Tests of a Tractor Rollover Detection and Emergency Notification System.

    PubMed

    Liu, B; Koc, A B

    2015-04-01

    The objective of this research was to assess the feasibility of a rollover detection and emergency notification system for farm tractors using field tests. The emergency notification system was developed based on a tractor stability model and implemented on a mobile electronic device with the iOS operating system. A complementary filter was implemented to combine the data from the accelerometer and gyroscope sensors to improve their accuracies in calculating the roll and pitch angles and the roll and pitch rates. The system estimates a stability index value during tractor operation, displays feedback messages when the stability index is lower than a preset threshold value, and transmits emergency notification messages when an overturn happens. Ten tractor rollover tests were conducted on a field track. The developed system successfully monitored the stability of the tractor during all of the tests. The iOS application was able to detect rollover accidents and transmit emergency notifications in the form of a phone call and email when an accident was detected. The system can be a useful tool for training and education in safe tractor operation. The system also has potential for stability monitoring and emergency notification of other on-road and off-road motorized vehicles.

  2. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    USGS Publications Warehouse

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  3. Experimental field test of proposed pedestrian safety messages. Volume 2, Child messages

    DOT National Transportation Integrated Search

    1983-11-01

    Author's abstract: A detailed re-analysis of available pedestrian accident data was utilized to define three sets of pedestrian safety public information and education (PI&E) messages. These messages were then produced and field tested. The objective...

  4. Ethical Issues and Questions about Testing for Test Publishers.

    ERIC Educational Resources Information Center

    Fitzgibbon, Thomas J.

    The test publisher's responsibility is discussed. "Right and good conduct" of the publisher in relation to the desires of the test user is related to the actual age of the test--old versus new materials. Other issues confronting the test publisher are the conflict between the needs for personal privacy and the claims of the community in relation…

  5. Field test of wavelength-saving quantum key distribution network.

    PubMed

    Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Zhang, Yang; Zhang, Tao; Li, Hong-Wei; Xu, Fang-Xing; Zhou, Zheng; Yang, Yang; Huang, Da-Jun; Zhang, Li-Jun; Li, Fang-Yi; Liu, Dong; Wang, Yong-Gang; Guo, Guang-Can; Han, Zheng-Fu

    2010-07-15

    We propose a wavelength-saving topology of a quantum key distribution (QKD) network based on passive optical elements, and we report on the field test of this network on commercial telecom optical fiber at the frequency of 20 MHz. In this network, five nodes are supported with two wavelengths, and every two nodes can share secure keys directly at the same time. We also characterized the insertion loss and cross talk effects on the point-to-point QKD system after introducing this QKD network.

  6. Determination of antenna factors using a three-antenna method at open-field test site

    NASA Astrophysics Data System (ADS)

    Masuzawa, Hiroshi; Tejima, Teruo; Harima, Katsushige; Morikawa, Takao

    1992-09-01

    Recently NIST has used the three-antenna method for calibration of the antenna factor of an antenna used for EMI measurements. This method does not require the specially designed standard antennas which are necessary in the standard field method or the standard antenna method, and can be used at an open-field test site. This paper theoretically and experimentally examines the measurement errors of this method and evaluates the precision of the antenna-factor calibration. It is found that the main source of the error is the non-ideal propagation characteristics of the test site, which should therefore be measured before the calibration. The precision of the antenna-factor calibration at the test site used in these experiments, is estimated to be 0.5 dB.

  7. Comparing Derived and Actual Upwelling Longwave Measurements at the CERES Ocean Validation Experiment (COVE)

    NASA Astrophysics Data System (ADS)

    Fabbri, B. E.; Schuster, G. L.; Denn, F. M.; Arduini, R. F.; Madigan, J. J.

    2017-12-01

    One of the parameters measured from the Clouds and the Earth's Radiant Energy System (CERES) satellite is Earth emitted or longwave (LW) radiation. One validation site to compare this quantity is the CERES Ocean Validation Experiment (COVE), located at Chesapeake Light Station, approximately 25 kilometers east of Virginia Beach, Virginia (coordinates: 36.90N, 75.71W). However, the upwelling measurement is complicated due to the Light Station tower being in the LW instruments field of view. A negative outcome of the tower being in the field of view is a tower radiating effect, especially noticeable on clear, sunny days. During these days, the tower tends to heat up and radiate extra heat energy that is measured by the LW instrument. To understand the extent of the problem, we derive upwelling longwave measurements at the surface using sea surface temperature, air temperature, and dewpoint to compare with the actual longwave measurement made with an Eppley Laboratory pyrgeometer. The data used in this study is over a four-year period (2009-2012). One result using only nighttime data (range: 15.0 =< sa <= 55.0) shows the relative error between actual versus derived being low. The resultant statistics produced a mean, median, standard deviation and standard error to be -0.378, -0.14, 1.906 and 0.005 respectively. This low error is not too surprising since there is no solar insolation creating the tower radiating effect. Other results comparing the diurnal scope are analyzed and presented.

  8. The Validity of the Major Field Test in Psychology as a Programme Assessment Tool

    ERIC Educational Resources Information Center

    Gallagher, Shawn P.; Cook, Shaun P.

    2013-01-01

    The Major Field Test in Psychology (MFT) is a standardised test designed to assess subject mastery at the conclusion of an undergraduate career. Eighty-one graduating majors completed the MFT and 56 of them also took a multiple-choice exam of questions drawn randomly from an introductory psychology test bank. Like the MFT, the constructed exam was…

  9. SafeTrip-21 : Federal ITS field tests to transform the traveler experience.

    DOT National Transportation Integrated Search

    2011-06-30

    SafeTrip-21 popularized transportation technology by making traffic and transit data available to the public via websites, smartphone apps, and other electronic media. Federal ITS field tests were carried out between November 2008 and November 2010 i...

  10. Reverberation Chamber Uniformity Validation and Radiated Susceptibility Test Procedures for the NASA High Intensity Radiated Fields Laboratory

    NASA Technical Reports Server (NTRS)

    Koppen, Sandra V.; Nguyen, Truong X.; Mielnik, John J.

    2010-01-01

    The NASA Langley Research Center's High Intensity Radiated Fields Laboratory has developed a capability based on the RTCA/DO-160F Section 20 guidelines for radiated electromagnetic susceptibility testing in reverberation chambers. Phase 1 of the test procedure utilizes mode-tuned stirrer techniques and E-field probe measurements to validate chamber uniformity, determines chamber loading effects, and defines a radiated susceptibility test process. The test procedure is segmented into numbered operations that are largely software controlled. This document is intended as a laboratory test reference and includes diagrams of test setups, equipment lists, as well as test results and analysis. Phase 2 of development is discussed.

  11. Remote sensing and field test capabilities at U.S. Army Dugway Proving Ground

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Herron, Joshua P.; Marshall, Martin S.

    2011-11-01

    U.S. Army Dugway Proving Ground (DPG) is a Major Range and Test Facility Base (MRTFB) with the mission of testing chemical and biological defense systems and materials. DPG facilities include state-of-the-art laboratories, extensive test grids, controlled environment calibration facilities, and a variety of referee instruments for required test measurements. Among these referee instruments, DPG has built up a significant remote sensing capability for both chemical and biological detection. Technologies employed for remote sensing include FTIR spectroscopy, UV spectroscopy, Raman-shifted eye-safe lidar, and other elastic backscatter lidar systems. These systems provide referee data for bio-simulants, chemical simulants, toxic industrial chemicals (TICs), and toxic industrial materials (TIMs). In order to realize a successful large scale open-air test, each type of system requires calibration and characterization. DPG has developed specific calibration facilities to meet this need. These facilities are the Joint Ambient Breeze Tunnel (JABT), and the Active Standoff Chamber (ASC). The JABT and ASC are open ended controlled environment tunnels. Each includes validation instrumentation to characterize simulants that are disseminated. Standoff systems are positioned at typical field test distances to measure characterized simulants within the tunnel. Data from different types of systems can be easily correlated using this method, making later open air test results more meaningful. DPG has a variety of large scale test grids available for field tests. After and during testing, data from the various referee instruments is provided in a visual format to more easily draw conclusions on the results. This presentation provides an overview of DPG's standoff testing facilities and capabilities, as well as example data from different test scenarios.

  12. Remote sensing and field test capabilities at U.S. Army Dugway Proving Ground

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Herron, Joshua P.; Marshall, Martin S.

    2012-05-01

    U.S. Army Dugway Proving Ground (DPG) is a Major Range and Test Facility Base (MRTFB) with the mission of testing chemical and biological defense systems and materials. DPG facilities include state-of-the-art laboratories, extensive test grids, controlled environment calibration facilities, and a variety of referee instruments for required test measurements. Among these referee instruments, DPG has built up a significant remote sensing capability for both chemical and biological detection. Technologies employed for remote sensing include FTIR spectroscopy, UV spectroscopy, Raman-shifted eye-safe lidar, and other elastic backscatter lidar systems. These systems provide referee data for bio-simulants, chemical simulants, toxic industrial chemicals (TICs), and toxic industrial materials (TIMs). In order to realize a successful large scale open-air test, each type of system requires calibration and characterization. DPG has developed specific calibration facilities to meet this need. These facilities are the Joint Ambient Breeze Tunnel (JABT), and the Active Standoff Chamber (ASC). The JABT and ASC are open ended controlled environment tunnels. Each includes validation instrumentation to characterize simulants that are disseminated. Standoff systems are positioned at typical field test distances to measure characterized simulants within the tunnel. Data from different types of systems can be easily correlated using this method, making later open air test results more meaningful. DPG has a variety of large scale test grids available for field tests. After and during testing, data from the various referee instruments is provided in a visual format to more easily draw conclusions on the results. This presentation provides an overview of DPG's standoff testing facilities and capabilities, as well as example data from different test scenarios.

  13. Testing neoclassical competitive market theory in the field.

    PubMed

    List, John A

    2002-11-26

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process.

  14. Testing neoclassical competitive market theory in the field

    PubMed Central

    List, John A.

    2002-01-01

    This study presents results from a pilot field experiment that tests predictions of competitive market theory. A major advantage of this particular field experimental design is that my laboratory is the marketplace: subjects are engaged in buying, selling, and trading activities whether I run an exchange experiment or am a passive observer. In this sense, I am gathering data in a natural environment while still maintaining the necessary control to execute a clean comparison between treatments. The main results of the study fall into two categories. First, the competitive model predicts reasonably well in some market treatments: the expected price and quantity levels are approximated in many market rounds. Second, the data suggest that market composition is important: buyer and seller experience levels impact not only the distribution of rents but also the overall level of rents captured. An unexpected result in this regard is that average market efficiency is lowest in markets that match experienced buyers and experienced sellers and highest when experienced buyers engage in bargaining with inexperienced sellers. Together, these results suggest that both market experience and market composition play an important role in the equilibrium discovery process. PMID:12432103

  15. ff14ipq: A Self-Consistent Force Field for Condensed-Phase Simulations of Proteins

    PubMed Central

    2015-01-01

    We present the ff14ipq force field, implementing the previously published IPolQ charge set for simulations of complete proteins. Minor modifications to the charge derivation scheme and van der Waals interactions between polar atoms are introduced. Torsion parameters are developed through a generational learning approach, based on gas-phase MP2/cc-pVTZ single-point energies computed of structures optimized by the force field itself rather than the quantum benchmark. In this manner, we sacrifice information about the true quantum minima in order to ensure that the force field maintains optimal agreement with the MP2/cc-pVTZ benchmark for the ensembles it will actually produce in simulations. A means of making the gas-phase torsion parameters compatible with solution-phase IPolQ charges is presented. The ff14ipq model is an alternative to ff99SB and other Amber force fields for protein simulations in programs that accommodate pair-specific Lennard–Jones combining rules. The force field gives strong performance on α-helical and β-sheet oligopeptides as well as globular proteins over microsecond time scale simulations, although it has not yet been tested in conjunction with lipid and nucleic acid models. We show how our choices in parameter development influence the resulting force field and how other choices that may have appeared reasonable would actually have led to poorer results. The tools we developed may also aid in the development of future fixed-charge and even polarizable biomolecular force fields. PMID:25328495

  16. Analysis of field size distributions, LACIE test sites 5029, 5033, and 5039, Anhwei Province, People's Republic of China

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.

    1976-01-01

    A study was made of the field size distributions for LACIE test sites 5029, 5033, and 5039, People's Republic of China. Field lengths and widths were measured from LANDSAT imagery, and field area was statistically modeled. Field size parameters have log-normal or Poisson frequency distributions. These were normalized to the Gaussian distribution and theoretical population curves were made. When compared to fields in other areas of the same country measured in the previous study, field lengths and widths in the three LACIE test sites were 2 to 3 times smaller and areas were smaller by an order of magnitude.

  17. The use of statistical tools in field testing of putative effects of genetically modified plants on nontarget organisms

    PubMed Central

    Semenov, Alexander V; Elsas, Jan Dirk; Glandorf, Debora C M; Schilthuizen, Menno; Boer, Willem F

    2013-01-01

    Abstract To fulfill existing guidelines, applicants that aim to place their genetically modified (GM) insect-resistant crop plants on the market are required to provide data from field experiments that address the potential impacts of the GM plants on nontarget organisms (NTO's). Such data may be based on varied experimental designs. The recent EFSA guidance document for environmental risk assessment (2010) does not provide clear and structured suggestions that address the statistics of field trials on effects on NTO's. This review examines existing practices in GM plant field testing such as the way of randomization, replication, and pseudoreplication. Emphasis is placed on the importance of design features used for the field trials in which effects on NTO's are assessed. The importance of statistical power and the positive and negative aspects of various statistical models are discussed. Equivalence and difference testing are compared, and the importance of checking the distribution of experimental data is stressed to decide on the selection of the proper statistical model. While for continuous data (e.g., pH and temperature) classical statistical approaches – for example, analysis of variance (ANOVA) – are appropriate, for discontinuous data (counts) only generalized linear models (GLM) are shown to be efficient. There is no golden rule as to which statistical test is the most appropriate for any experimental situation. In particular, in experiments in which block designs are used and covariates play a role GLMs should be used. Generic advice is offered that will help in both the setting up of field testing and the interpretation and data analysis of the data obtained in this testing. The combination of decision trees and a checklist for field trials, which are provided, will help in the interpretation of the statistical analyses of field trials and to assess whether such analyses were correctly applied. We offer generic advice to risk assessors and

  18. The use of statistical tools in field testing of putative effects of genetically modified plants on nontarget organisms.

    PubMed

    Semenov, Alexander V; Elsas, Jan Dirk; Glandorf, Debora C M; Schilthuizen, Menno; Boer, Willem F

    2013-08-01

    To fulfill existing guidelines, applicants that aim to place their genetically modified (GM) insect-resistant crop plants on the market are required to provide data from field experiments that address the potential impacts of the GM plants on nontarget organisms (NTO's). Such data may be based on varied experimental designs. The recent EFSA guidance document for environmental risk assessment (2010) does not provide clear and structured suggestions that address the statistics of field trials on effects on NTO's. This review examines existing practices in GM plant field testing such as the way of randomization, replication, and pseudoreplication. Emphasis is placed on the importance of design features used for the field trials in which effects on NTO's are assessed. The importance of statistical power and the positive and negative aspects of various statistical models are discussed. Equivalence and difference testing are compared, and the importance of checking the distribution of experimental data is stressed to decide on the selection of the proper statistical model. While for continuous data (e.g., pH and temperature) classical statistical approaches - for example, analysis of variance (ANOVA) - are appropriate, for discontinuous data (counts) only generalized linear models (GLM) are shown to be efficient. There is no golden rule as to which statistical test is the most appropriate for any experimental situation. In particular, in experiments in which block designs are used and covariates play a role GLMs should be used. Generic advice is offered that will help in both the setting up of field testing and the interpretation and data analysis of the data obtained in this testing. The combination of decision trees and a checklist for field trials, which are provided, will help in the interpretation of the statistical analyses of field trials and to assess whether such analyses were correctly applied. We offer generic advice to risk assessors and applicants that will

  19. Tests and applications of nonlinear force-free field extrapolations in spherical geometry

    NASA Astrophysics Data System (ADS)

    Guo, Y.; Ding, M. D.

    2013-07-01

    We test a nonlinear force-free field (NLFFF) optimization code in spherical geometry with an analytical solution from Low and Lou. The potential field source surface (PFSS) model is served as the initial and boundary conditions where observed data are not available. The analytical solution can be well recovered if the boundary and initial conditions are properly handled. Next, we discuss the preprocessing procedure for the noisy bottom boundary data, and find that preprocessing is necessary for NLFFF extrapolations when we use the observed photospheric magnetic field as bottom boundaries. Finally, we apply the NLFFF model to a solar area where four active regions interacting with each other. An M8.7 flare occurred in one active region. NLFFF modeling in spherical geometry simultaneously constructs the small and large scale magnetic field configurations better than the PFSS model does.

  20. Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 5 Full-Scale Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe; MariJon Owens

    2007-12-01

    This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from the FGD liquor and bulkmore » solid byproducts for separate disposal. The project is conducting pilot- and full-scale tests of the additives in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power has provided the Texas lignite/PRB co-fired test site for pilot FGD tests and cost sharing. Southern Company has provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation is providing the TMT-15 additive, and the Nalco Company is providing the Nalco 8034 additive. Both companies are also supplying technical support to the test program as in-kind cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves

  1. Report of the Field Testing and Validation of Expanding Career Horizons.

    ERIC Educational Resources Information Center

    Fink, Arlene; Kosecoff, Jacqueline

    A three-phase assessment was conducted to field test a curriculum developed to expand career horizons for both young men and young women and to help eliminate sex role stereotyping. Intended for grades 7-14, this curriculum emphasized the increasing options for women in vocational education programs and non-traditional careers. First, the…

  2. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12more » refs.)« less

  3. Nominal vs. actual supersaturation of solutions

    NASA Astrophysics Data System (ADS)

    Borisenko, Alexander

    2018-03-01

    Following the formalism of the Classical Nucleation Theory beyond the dilute solution approximation, this paper considers a difference between the actual solute supersaturation (given by the present-to-saturated solute activity ratio) and the nominal supersaturation (given by the present-to-saturated solute concentration ratio) due to formation of subcritical transient solute clusters, called heterophase fluctuations. Based on their distribution function, we introduce an algebraic equation of supersaturation that couples the nominal supersaturation of a binary metastable solution with its actual supersaturation and a function of the specific interface energy and temperature. The applicability of this approach is validated by comparison to simulation data [(Clouet et al., Phys. Rev. B 69, 064109 (2004)] on nucleation of Al3Zr and Al3Sc in model binary Al alloys.

  4. Self-Actualization in a Marathon Growth Group: Do the Strong Get Stronger?

    ERIC Educational Resources Information Center

    Kimball, Ronald; Gelso, Charles J.

    1974-01-01

    This study examined the effects of a weekend marathon on the level of self-actualization of college students and the relationship between ego strength and extent of change in self-actualization. The group experience did increase self-actualization, but participants' initial level of ego strength was unrelated to changes in self-actualization.…

  5. Development of TiO2 powder-coated food packaging film and its ability to inactivate Escherichia coli in vitro and in actual tests.

    PubMed

    Chawengkijwanich, Chamorn; Hayata, Yasuyoshi

    2008-04-30

    Titanium dioxide (TiO2) has attracted a great deal of attention as a photocatalytic disinfecting material in the food and environmental industry. TiO2 has been used to inactivate a wide variety of microorganisms in many applications. In the present study, we aimed to develop a TiO2 powder-coated packaging film and clarify its ability to inactivate Escherichia coli both in vitro and in actual tests, using two different particle sizes and two types of illumination at different intensities. No inhibition effect of the testing method itself on the growth of E. coli was observed. The cells of E. coli were found to have decreased 3 log CFU/ml after 180 min of illumination by two 20 W black-light bulbs (wavelength of 300-400 nm) on TiO2-coated oriented-polypropylene (OPP) film, while E. coli decreased 1 log CFU/m with black-light illumination of uncoated OPP film. The results showed that both ultraviolet A (UVA; wavelength of 315-400 nm) alone and TiO2-coated OPP film combined with UVA reduced the number of E. coli cell in vitro, but that the reduction of E. coli cell numbers was greater by TiO2-coated OPP film combined with UVA. The antimicrobial effect of TiO2-coated film is dependent on the UVA light intensity (0, <0.05 and 1 mW/cm2) and the kind of artificial light (black-light and daylight fluorescent bulbs), but it is independent of the particle size of TiO2 coating on the surface of OPP film. The surviving cell numbers of E. coli on TiO2-coated film decreased 3 log and 0.35 log CFU/ml after 180 min of illumination by two 20 W black bulbs and two 20 W daylight fluorescent bulbs, respectively. Despite the lesser efficacy of the photocatalytic method with fluorescent lights, the survival of E. coli cells using this method was 50% of that using fluorescent lights alone. In the actual test, the number of E. coli cells from cut lettuce stored in a TiO2-coated film bag irradiated with UVA light decreased from 6.4 on Day 0 to 4.9 log CFU/g on Day 1, while that of an

  6. Expected satiation alone does not predict actual intake of desserts.

    PubMed

    Guillocheau, Etienne; Davidenko, Olga; Marsset-Baglieri, Agnès; Darcel, Nicolas; Gaudichon, Claire; Tomé, Daniel; Fromentin, Gilles

    2018-04-01

    The degree to which consumers expect foods to satisfy hunger, referred to as expected satiation, has been reported to predict food intake. Yet this relationship has not been established precisely, at a quantitative level. We sought to explore this relationship in detail by determining whether expected satiation predicts the actual intake of semi-solid desserts. Two separate experiments were performed: the first used variations of a given food (eight apple purées), while the second involved a panel of different foods within a given category (eight desserts). Both experiments studied the consumption of two products assigned to volunteers based on their individual liking and expected satiation ratings, given ad libitum at the end of a standardised meal. A linear model was used to find predictors of food intake and included expected satiation scores, palatability scores, BMI, age, sex, TFEQ-R, TFEQ-D, water consumption during the meal, reported frequency of eating desserts, and reported frequency of consuming tested products as explanatory variables. Expected satiation was a significant predictor of actual food intake in both experiments (apple purée: F(1,97) = 18.60, P < .001; desserts: F(1,106) = 9.05, P < .01), along with other parameters such as product palatability and the volunteers' age, sex and food restriction (variation explained by the model/expected satiation in the experiments: 57%/23% and 36%/17%, respectively). However, we found a significant gap between expected and actual consumption of desserts, on group and on individual level. Our results confirm the importance of expected satiation as a predictor of subsequent food intake, but highlight the need to study individual consumption behaviour and preferences in order to fully understand the role of expected satiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Field Testing of a Wet FGD Additive for Enhanced Mercury Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary Blythe; MariJon Owens

    2007-12-31

    This document is the final report for DOE-NETL Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project has been to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project was intended to demonstrate whether such additives can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from themore » FGD liquor and bulk solid byproducts for separate disposal. The project involved pilot- and full-scale tests of the additives in wet FGD absorbers. The tests were intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power provided the Texas lignite/PRB co-fired test site for pilot FGD tests and project cost sharing. Southern Company provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested, and project cost sharing. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation provided the TMT-15 additive, and the Nalco Company provided the Nalco 8034 additive. Both companies also supplied technical support to the test program as in-kind cost sharing. The project was conducted in six tasks. Of the six tasks, Task 1 involved project planning and Task 6 involved

  8. Application of historical mobility testing to sensor-based robotic performance

    NASA Astrophysics Data System (ADS)

    Willoughby, William E.; Jones, Randolph A.; Mason, George L.; Shoop, Sally A.; Lever, James H.

    2006-05-01

    The USA Engineer Research and Development Center (ERDC) has conducted on-/off-road experimental field testing with full-sized and scale-model military vehicles for more than fifty years. Some 4000 acres of local terrain are available for tailored field evaluations or verification/validation of future robotic designs in a variety of climatic regimes. Field testing and data collection procedures, as well as techniques for quantifying terrain in engineering terms, have been developed and refined into algorithms and models for predicting vehicle-terrain interactions and resulting forces or speeds of military-sized vehicles. Based on recent experiments with Matilda, Talon, and Pacbot, these predictive capabilities appear to be relevant to most robotic systems currently in development. Utilization of current testing capabilities with sensor-based vehicle drivers, or use of the procedures for terrain quantification from sensor data, would immediately apply some fifty years of historical knowledge to the development, refinement, and implementation of future robotic systems. Additionally, translation of sensor-collected terrain data into engineering terms would allow assessment of robotic performance a priori deployment of the actual system and ensure maximum system performance in the theater of operation.

  9. Could Magnetic Fields Affect the Circadian Clock Function of Cryptochromes? Testing the Basic Premise of the Cryptochrome Hypothesis (ELF Magnetic Fields).

    PubMed

    Vanderstraeten, Jacques; Burda, Hynek; Verschaeve, Luc; De Brouwer, Christophe

    2015-07-01

    It has been suggested that weak 50/60 Hz [extremely low frequency (ELF)] magnetic fields (MF) could affect circadian biorhythms by disrupting the clock function of cryptochromes (the "cryptochrome hypothesis," currently under study). That hypothesis is based on the premise that weak (Earth strength) static magnetic fields affect the redox balance of cryptochromes, thus possibly their signaling state as well. An appropriate method for testing this postulate could be real time or short-term study of the circadian clock function of retinal cryptochromes under exposure to the static field intensities that elicit the largest redox changes (maximal "low field" and "high field" effects, respectively) compared to zero field. Positive results might encourage further study of the cryptochrome hypothesis itself. However, they would indicate the need for performing a similar study, this time comparing the effects of only slight intensity changes (low field range) in order to explore the possible role of the proximity of metal structures and furniture as a confounder under the cryptochrome hypothesis.

  10. Integrated vehicle-based safety systems : heavy-truck field operational test independent evaluation.

    DOT National Transportation Integrated Search

    2011-05-01

    This report presents results from the independent evaluation of a field operational test using a fleet of heavy trucks outfitted with a prototype integrated crash warning system. This effort was conducted as part of the U.S. DOT?s Integrated Vehicle-...

  11. Water Quality: A Field-Based Quality Testing Program for Middle Schools and High Schools.

    ERIC Educational Resources Information Center

    Massachusetts State Water Resources Authority, Boston.

    This manual contains background information, lesson ideas, procedures, data collection and reporting forms, suggestions for interpreting results, and extension activities to complement a water quality field testing program. Information on testing water temperature, water pH, dissolved oxygen content, biochemical oxygen demand, nitrates, total…

  12. Draft Test Guideline: Field Testing For Aquatic Organisms

    EPA Pesticide Factsheets

    The following draft test guideline is part of a series of test guidelines that have been developed by EPA for use in the testing of pesticides and toxic substances, and the development of test data for submission to the Agency for review.

  13. [Arizona] Field Test Report. Vol. 10. Learn to Earn. 1974-75.

    ERIC Educational Resources Information Center

    Small, Charles; And Others

    The field test report on the "Learn to Earn" instructional unit for grade 6 is one of a series of reports on the Arizona developed Career Education Curriculum Units. Presented is specific information as to the success of the units in terms of the learner's cognitive, affective, and psychomotor behavior according to expressed performance…

  14. Self-actualization: Its Use and Misuse in Teacher Education.

    ERIC Educational Resources Information Center

    Ivie, Stanley D.

    1982-01-01

    The writings of Abraham Maslow are analyzed to determine the meaning of the psychological term "self-actualization." After pointing out that self-actualization is a rare quality and that it has little to do with formal education, the author concludes that the concept has little practical relevance for teacher education. (PP)

  15. Case Studies of Self-Actualization.

    ERIC Educational Resources Information Center

    Brennan, Thomas P.; Piechowski, Michael M.

    Case studies of self-actualizing people according to the ideas of A. Maslow and the criteria of K. Dabrowski are presented. To find people meeting the criteria of Level 4 of the Dabrowski theory, a pool of 21 subjects was established by nomination. All subjects were given the Definition-Response Instrument to assess levels of emotional…

  16. 7 CFR 400.55 - Qualification for actual production history coverage program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 6 2014-01-01 2014-01-01 false Qualification for actual production history coverage... Production History § 400.55 Qualification for actual production history coverage program. (a) The approved... history is certified and T or D-Yields are not provided in the actuarial documents, (2) If actual yield...

  17. Characterization Efforts in a Deep Borehole Field Test

    NASA Astrophysics Data System (ADS)

    Kuhlman, K. L.; Sassani, D.; Freeze, G. A.; Hardin, E. L.; Brady, P. V.

    2016-12-01

    The US Department of Energy Office of Nuclear Energy is embarking on a Deep Borehole Field Test to investigate the feasibility of constructing and characterizing two boreholes in crystalline basement rock to a depth of 5 km (16,400 ft). The concept of deep borehole disposal for radioactive waste has some advantages, including incremental construction and loading and the enhanced natural barriers provided by deep continental crystalline basement. Site characterization activities will include geomechanical (i.e., hydrofracture stress measurements), geological (i.e., core and mud logging), hydrological (i.e., packer-based pulse and pumping tests), and chemical (i.e., fluids sampled in situ from packer intervals and extracted from cores) tests. Borehole-based characterization will be used to determine the variability of system state (i.e., stress, pressure, temperature, and chemistry) with depth and interpretation of material and system parameters relevant to numerical site simulation. We explore the effects fluid density and geothermal temperature gradients (i.e., thermohaline convection) have on characterization goals in light of expected downhole conditions, including a disturbed rock zone surrounding the borehole. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  18. Field testing of new-technology ambient air ozone monitors.

    PubMed

    Ollison, Will M; Crow, Walt; Spicer, Chester W

    2013-07-01

    Multibillion-dollar strategies control ambient air ozone (O3) levels in the United States, so it is essential that the measurements made to assess compliance with regulations be accurate. The predominant method employed to monitor O3 is ultraviolet (UV) photometry. Instruments employ a selective manganese dioxide or heated silver wool "scrubber" to remove O3 to provide a zero reference signal. Unfortunately, such scrubbers remove atmospheric constituents that absorb 254-nm light, causing measurement interference. Water vapor also interferes with the measurement under some circumstances. We report results of a 3-month field test of two new instruments designed to minimize interferences (2B Technologies model 211; Teledyne-API model 265E) that were operated in parallel with a conventional Thermo Scientific model 49C O3 monitor. The field test was hosted by the Houston Regional Monitoring Corporation (HRM). The model 211 photometer scrubs O3 with excess nitric oxide (NO) generated in situ by photolysis of added nitrous oxide (N2O) to provide a reference signal, eliminating the need for a conventional O3 scrubber. The model 265E analyzer directly measures O3-NO chemiluminescence from added excess NO to quantify O3 in the sample stream. Extensive quality control (QC) and collocated monitoring data are assessed to evaluate potential improvements to the accuracy of O3 compliance monitoring. Two new-technology ozone monitors were compared with a conventional monitor under field conditions. Over 3 months the conventional monitor reported more exceedances of the current standard than the new instruments, which could potentially result in an area being misjudged as "nonattainment." Instrument drift can affect O3 data accuracy, and the same degree of drift has a proportionally greater compliance effect as standard stringency is increased. Enhanced data quality assurance and data adjustment may be necessary to achieve the improved accuracy required to judge compliance with

  19. Lesion correlates of impairments in actual tool use following unilateral brain damage.

    PubMed

    Salazar-López, E; Schwaiger, B J; Hermsdörfer, J

    2016-04-01

    To understand how the brain controls actions involving tools, tests have been developed employing different paradigms such as pantomime, imitation and real tool use. The relevant areas have been localized in the premotor cortex, the middle temporal gyrus and the superior and inferior parietal lobe. This study employs Voxel Lesion Symptom Mapping to relate the functional impairment in actual tool use with extent and localization of the structural damage in the left (LBD, N=31) and right (RBD, N=19) hemisphere in chronic stroke patients. A series of 12 tools was presented to participants in a carousel. In addition, a non-tool condition tested the prescribed manipulation of a bar. The execution was scored according to an apraxic error scale based on the dimensions grasp, movement, direction and space. Results in the LBD group show that the ventro-dorsal stream constitutes the core of the defective network responsible for impaired tool use; it is composed of the inferior parietal lobe, the supramarginal and angular gyrus and the dorsal premotor cortex. In addition, involvement of regions in the temporal lobe, the rolandic operculum, the ventral premotor cortex and the middle occipital gyrus provide evidence of the role of the ventral stream in this task. Brain areas related to the use of the bar largely overlapped with this network. For patients with RBD data were less conclusive; however, a trend for the involvement of the temporal lobe in apraxic errors was manifested. Skilled bar manipulation depended on the same temporal area in these patients. Therefore, actual tool use depends on a well described left fronto-parietal-temporal network. RBD affects actual tool use, however the underlying neural processes may be more widely distributed and more heterogeneous. Goal directed manipulation of non-tool objects seems to involve very similar brain areas as tool use, suggesting that both types of manipulation share identical processes and neural representations. Copyright

  20. How to Conduct a Research Field Trip

    ERIC Educational Resources Information Center

    Wacker, David G.

    1974-01-01

    Discusses the three phases of a three-day intensive research study field trip: planning and pre-trip training; actual trip; and post-trip report, research and data organization, and final trip evaluation. Included is a sample program of the limnology field trip taken by the Grafton High School, Wisconsin. (CC)

  1. Debris Flow Risk mitigation by the means of flexible barriers. Experimental and field tests.

    NASA Astrophysics Data System (ADS)

    Canelli, L.; Ferrero, A. M.; Segalini, A.

    2012-04-01

    Debris flow risk mitigation using net barriers is an option that was not considered until few years ago, probably because of the lack of scientific evidences about their efficiency and solid guidelines for their design and construction. On site evidences (Segalini et al, 2008) showed that a rock fall deformable barrier can efficiently intercept the whole volume or just a portion of the mobilized debris without losing its stability and efficiency, actually performing a different task form that it was originally designed for. Although the final purpose of both types of barriers (rock fall and debris) is to reduce the impact energy of the moving mass by dissipating impact energy through the deformation of the net and of the dissipating elements, it is noteworthy that the physics of the impact is extremely different between the two phenomena. The rock fall barrier needs to dissipate the energy of a single block generally concentrated on the center of the net panel (design conditions). The debris flow barrier, generally installed inside a debris channel, should be able to dissipate the impact energy that the debris induces across the whole section of the channel. Moreover, the recurring characteristic of the debris flows will cause multiple impact on the barrier and therefore, the structure should be able to absorb a significant amount of energy even if partially filled and considerably deformed. In order to introduce useful guidelines for the design and production of debris flow net barriers, this paper describes: 1. Part of the results obtained from the laboratory experiment carried out in a scaled channel and aimed to estimate the most realistic thrust vs time relationship induced by a debris flow on a deformable and rigid structure; these results were partially presented last year at the EGU 2011; 2. A large scale field test carried out in a quarry located in Tambre d'Alpago (Belluno Province) on the Eastern Italian Dolomites for the analysis of the behavior of a

  2. Linking manipulative experiments to field data to test the dilution effect.

    PubMed

    Venesky, Matthew D; Liu, Xuan; Sauer, Erin L; Rohr, Jason R

    2014-05-01

    The dilution effect, the hypothesis that biodiversity reduces disease risk, has received support in many systems. However, few dilution effect studies have linked mechanistic experiments to field patterns to establish both causality and ecological relevance. We conducted a series of laboratory experiments and tested the dilution effect hypothesis in an amphibian-Batrachochytrium dendrobatidis (Bd) system and tested for consistency between our laboratory experiments and field patterns of amphibian species richness, host identity and Bd prevalence. In our laboratory experiments, we show that tadpoles can filter feed Bd zoospores and that the degree of suspension feeding was positively associated with their dilution potential. The obligate suspension feeder, Gastrophryne carolinensis, generally diluted the risk of chytridiomycosis for tadpoles of Bufo terrestris and Hyla cinerea, whereas tadpoles of B. terrestris (an obligate benthos feeder) generally amplified infections for the other species. In addition, G. carolinensis reduced Bd abundance on H. cinerea more so in the presence than absence of B. terrestris and B. terrestris amplified Bd abundance on H. cinerea more so in the absence than presence of G. carolinensis. Also, when ignoring species identity, species richness was a significant negative predictor of Bd abundance. In our analysis of field data, the presence of Bufo spp. and Gastrophryne spp. were significant positive and negative predictors of Bd prevalence, respectively, even after controlling for climate, vegetation, anthropogenic factors (human footprint), species richness and sampling effort. These patterns of dilution and amplification supported our laboratory findings, demonstrating that the results are likely ecologically relevant. The results from our laboratory and field data support the dilution effect hypothesis and also suggest that dilution and amplification are predictable based on host traits. Our study is among the first to link

  3. Cocaine phenomenology study: results of a third in a series of field trials

    NASA Astrophysics Data System (ADS)

    Su, Chih-Wu; Rigdon, Stephen W.; Ricard, Steve; Hoglund, David E.; Drolet, Gerry; Neudorfl, Pavel; Hupe, Michael; Kunz, Terry D.; Ulvick, Sydney J.; Demirgian, Jack C.; Shier, Patrick; Wingo, Jeff J.

    1997-01-01

    To form an understanding of the environment in which non- intrusive detection and inspection technologies are required to operate, the Narcotic Detection Technology assessment Team has undertaken a series of field studies. These field studies have focused on the phenomenology, fate and behavior of narcotic residue in real world environments. The overall goal of the tests is to give Law Enforcement officers the ability to accurately differentiate between individuals involved in the smuggling process and individuals innocently contaminated with narcotics. The latest filed study in this series was conducted in Miami, FL in February 1996. The field study comprised several individual tests. The first was a contamination and transfer study which focuses on human contamination resulting from contact with actual kilos of cocaine and the mechanism by which this contamination transfers to surrounding objects, if at all. The second was a secondary contamination study which focused on determining the conditions under which cocaine contamination transfers from objects touched by individuals who handled narcotics to innocent passerbys. The third was a persistence study which focused on the persistence of cocaine contamination on people under a variety of conditions. An overview of the tests and their preliminary results will be discussed.

  4. SmartPark Truck Parking Availability System: Magnetometer Technology Field Operational Test Results

    DOT National Transportation Integrated Search

    2011-01-01

    The purpose of FMCSAs SmartPark initiative is to determine the feasibility of a technology for providing truck parking space availability in real time to truckers on the road. SmartPark consists of two phases. Phase I was a field operational test ...

  5. SmartPark Truck Parking Availability System: Video Technology Field Operational Test Results

    DOT National Transportation Integrated Search

    2011-01-01

    The purpose of FMCSAs SmartPark initiative is to determine the feasibility of a technology for providing truck parking space availability in real time to truckers on the road. SmartPark consists of two phases. Phase I was a field operational test ...

  6. Objectives and first results of the NASA SETI sky survey field tests at Goldstone

    NASA Technical Reports Server (NTRS)

    Gulkis, S.; Klein, M. J.; Olsen, E. T.; Crow, R. B.; Gosline, R. M.; Downs, G. S.; Quirk, M. P.; Lokshin, A.; Solomon, J.

    1986-01-01

    Field tests of SETI (Search for Extraterrestrial Intelligence) prototype hardware and software began in March 1985 at Goldstone. With emphasis on the sky survey component of the NASA SETI search strategy, the article describes the survey characteristics, the detection strategy, and preliminary results of system tests.

  7. CFD analysis of a full-scale ceramic kiln module under actual operating conditions

    NASA Astrophysics Data System (ADS)

    Milani, Massimo; Montorsi, Luca; Stefani, Matteo; Venturelli, Matteo

    2017-11-01

    The paper focuses on the CFD analysis of a full-scale module of an industrial ceramic kiln under actual operating conditions. The multi-dimensional analysis includes the real geometry of a ceramic kiln module employed in the preheating and firing sections and investigates the heat transfer between the tiles and the burners' flame as well as the many components that comprise the module. Particular attention is devoted to the simulation of the convective flow field in the upper and lower chambers and to the effects of radiation on the different materials is addressed. The assessment of the radiation contribution to the tiles temperature is paramount to the improvement of the performance of the kiln in terms of energy efficiency and fuel consumption. The CFD analysis is combined to a lumped and distributed parameter model of the entire kiln in order to simulate the module behaviour at the boundaries under actual operating conditions. Finally, the CFD simulation is employed to address the effects of the module operating conditions on the tiles' temperature distribution in order to improve the temperature uniformity as well as to enhance the energy efficiency of the system and thus to reduce the fuel consumption.

  8. γ Pegasi: testing Vega-like magnetic fields in B stars

    NASA Astrophysics Data System (ADS)

    Neiner, C.; Monin, D.; Leroy, B.; Mathis, S.; Bohlender, D.

    2014-02-01

    Context. The bright B pulsator γ Peg shows both p and g modes of β Cep and SPB types. It has also been claimed that it is a magnetic star, while others do not detect any magnetic field. Aims: We check for the presence of a magnetic field, with the aim to characterise it if it exists, or else provide a firm upper limit of its strength if it is not detected. If γ Peg is magnetic as claimed, it would make an ideal asteroseismic target for testing various theoretical scenarios. If it is very weakly magnetic, it would be the first observation of an extension of Vega-like fields to early B stars. Finally, if it is not magnetic and we can provide a very low upper limit on its non-detected field, it would make an important result for stellar evolution models. Methods: We acquired high resolution, high signal-to-noise spectropolarimetric Narval data at Telescope Bernard Lyot (TBL). We also gathered existing dimaPol spectropolarimetric data from the Dominion Astrophysical Observatory (DAO) and Musicos spectropolarimetric data from TBL. We analysed the Narval and Musicos observations using the least-squares deconvolution (LSD) technique to derive the longitudinal magnetic field and Zeeman signatures in lines. The longitudinal field strength was also extracted from the Hβ line observed with the DAO. With a Monte Carlo simulation we derived the maximum strength of the field possibly hosted by γ Peg. Results: We find that no magnetic signatures are visible in the very high quality spectropolarimetric data. The average longitudinal field measured in the Narval data is Bl = -0.1 ± 0.4 G. We derive a very strict upper limit of the dipolar field strength of Bpol ~ 40 G. Conclusions: We conclude that γ Peg is not magnetic: it hosts neither a strong stable fossil field as observed in a fraction of massive stars nor a very weak Vega-like field. There is therefore no evidence that Vega-like fields exist in B stars, contrary to the predictions by fossil field dichotomy scenarios

  9. Biotechnology; Managing the Risks of Field Testing Genetically Engineered Organisms

    DTIC Science & Technology

    1988-06-01

    jurisdictional lines. The agencies’ principal regulatory tool for managing the risks of field testing genetically engineered organisms is the authority to...Regulatory authority has been established in numerous federal statutes designed to prevent the occurrence of harm to the environment and public health...would not be reviewed or regulated at all. According to the Insti- tute, "there are numerous organisms outside the confines of t he plant ST~( Iflt l l l

  10. Direct vision in minimally invasive epicardial procedures: preliminary tests of prototype instrumentation.

    PubMed

    Hack, B J; Ramon, S G; Hagen, Z A; Theran, M E; Burkhardt, J D; Gillies, G T

    2015-01-01

    This study investigated the use of direct visualization to enhance minimally invasive epicardial procedures. A commercially available miniature camera was placed in a prototype subxiphoid introducer needle and bench top, in vitro and in vivo tests of system performance were made during simulated and actual attempts at pericardial access and cardio-endoscopy. This system had an unshielded field of view of 100° and a resolution of 220 × 224 pixels. When a sleeve used to maintain depth of field was slid past the distal tip of the camera probe, the field of view would decrease by ≈15° per millimetre of sleeve extension, but without loss of image quality. While tests during in vivo subxiphoid access in a porcine model revealed that the pericardial membrane was difficult to localize, the results also showed excellent resolution of the coronary arteries on the epicardial surface. These findings and potential improvements are discussed in detail.

  11. Predictors of Home Radon Testing and Implications for Testing Promotion Programs.

    ERIC Educational Resources Information Center

    Sandman, Peter M.; Weinstein, Neil D.

    1993-01-01

    Analysis of 4 New Jersey studies of 3,329 homeowners found that (1) thinking about radon testing is predicted by general radon knowledge; (2) decision to test is related to perceived likelihood of risk; and (3) actual testing is influenced by situational factors such as locating and choosing test kits. (SK)

  12. Transport and attenuation of carboxylate-modified latex microspheres in fractured rock laboratory and field tracer tests

    USGS Publications Warehouse

    Becker, M.W.; Reimus, P.W.; Vilks, P.

    1999-01-01

    Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks of pathogen contamination in drinking water wells. Much has been learned through laboratory and field-scale colloid tracer tests, but progress has been hampered by a lack of consistent tracer testing methodology at different scales and fluid velocities. This paper presents laboratory and field tracer tests in fractured rock that use the same type of colloid tracer over an almost three orders-of-magnitude range in scale and fluid velocity. Fluorescently-dyed carboxylate-modified latex (CML) microspheres (0.19 to 0.98 ??m diameter) were used as tracers in (1) a naturally fractured tuff sample, (2) a large block of naturally fractured granite, (3) a fractured granite field site, and (4) another fractured granite/schist field site. In all cases, the mean transport time of the microspheres was shorter than the solutes, regardless of detection limit. In all but the smallest scale test, only a fraction of the injected microsphere mass was recovered, with the smaller microspheres being recovered to a greater extent than the larger microspheres. Using existing theory, we hypothesize that the observed microsphere early arrival was due to volume exclusion and attenuation was due to aggregation and/or settling during transport. In most tests, microspheres were detected using flow cytometry, which proved to be an excellent method of analysis. CML microspheres appear to be useful tracers for fractured rock in forced gradient and short-term natural gradient tests, but longer residence times may result in small microsphere recoveries.Understanding colloid transport in ground water is essential to assessing the migration of colloid-size contaminants, the facilitation of dissolved contaminant transport by colloids, in situ bioremediation, and the health risks

  13. Intelligent transportation systems field operational test cross-cutting study : commercial vehicle operations -- roadside

    DOT National Transportation Integrated Search

    1998-11-01

    Commercial Vehicle Operations - Roadside report discusses the findings and conclusions exclusively from Field Operational Tests (FOTs) of roadside Intelligent Transportation Systems (ITS) for Commercial Vehicle Operations (CVO). The FOTs considered i...

  14. A study of the electric field in an open magnetospheric model

    NASA Technical Reports Server (NTRS)

    Stern, D. P.

    1972-01-01

    The qualitative properties of an open magnetosphere and its electric field are examined and compared to a simple model of a dipole in a constant field and to actual observations. Many of these properties are found to depend on the separatrix, a curve connecting neutral points and separating different field-line regimes. In the simple model, the electric field in the central polar cap tends to point from dawn to dusk for a wide choice of external fields. Near the boundary of the polar cap electric equipotentials curve and become crescent-shaped, which may explain the correlation of polar magnetic variations with the azimuthal component of the interplanetary magnetic field, reported by Svalgaard. Modifications expected to occur in the actual magnetosphere are also investigated: in particular, it appears that bending of equipotentials may be reduced by cross-field flow during the merging of field lines and that open field lines connected to the polar caps emerge from a long and narrow slot extending along the tail.

  15. Perceived and actual social discrimination: the case of overweight and social inclusion.

    PubMed

    Hartung, Freda-Marie; Renner, Britta

    2013-01-01

    The present study examined the correspondence between perceived and actual social discrimination of overweight people. In total, 77 first-year students provided self-ratings about their height, weight, and perceived social inclusion. To capture actual social inclusion, each participant nominated those fellow students (a) she/he likes and dislikes and (b) about whom she/he is likely to hear social news. Students with lower Body Mass Index (BMI) felt socially included, irrespective of their actual social inclusion. In contrast, students with higher BMI felt socially included depending on the degree of their actual social inclusion. Specifically, their felt social inclusion accurately reflected whether they were actually liked/disliked, but only when they were part of social news. When not part of social news, they also showed insensitivity to their actual social inclusion status. Thus, students with a lower BMI tended to be insensitive, while students with a higher BMI showed a differential sensitivity to actual social discrimination.

  16. Realizing actual feedback control of complex network

    NASA Astrophysics Data System (ADS)

    Tu, Chengyi; Cheng, Yuhua

    2014-06-01

    In this paper, we present the concept of feedbackability and how to identify the Minimum Feedbackability Set of an arbitrary complex directed network. Furthermore, we design an estimator and a feedback controller accessing one MFS to realize actual feedback control, i.e. control the system to our desired state according to the estimated system internal state from the output of estimator. Last but not least, we perform numerical simulations of a small linear time-invariant dynamics network and a real simple food network to verify the theoretical results. The framework presented here could make an arbitrary complex directed network realize actual feedback control and deepen our understanding of complex systems.

  17. Marijuana, alcohol and actual driving performance

    DOT National Transportation Integrated Search

    1999-07-01

    The purpose of this study was to empirically determine the separate and combined effects of Delta-9-tetrahydrocannabinol (THC) and alcohol on actual driving performance. This was the first study ever in which the drugs' combined effects were measured...

  18. Education Longitudinal Study of 2002 (ELS:2002/12) Third Follow-up Field Test Report. Working Paper Series. NCES 2012-03

    ERIC Educational Resources Information Center

    Ingels, Steven J.; Pratt, Daniel J.; Jewell, Donna M.; Mattox, Tiffany; Dalton, Ben; Rosen, Jeffrey; Lauff, Erich; Hill, Jason

    2012-01-01

    This report describes the methodologies and results of the third follow-up Education Longitudinal Study of 2002 (ELS:2002/12) field test which was conducted in the summer of 2011. The field test report is divided into six chapters: (1) Introduction; (2) Field Test Survey Design and Preparation; (3) Data Collection Procedures and Results; (4) Field…

  19. Study optimizes gas lift in Gulf of Suez field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Waly, A.A.; Darwish, T.A.; Osman Salama, A.

    1996-06-24

    A study using PVT data combined with fluid and multiphase flow correlations optimized gas lift in the Ramadan field, Nubia C, oil wells, in the Gulf of Suez. Selection of appropriate correlations followed by multiphase flow calculations at various points of injection (POI) were the first steps in the study. After determining the POI for each well from actual pressure and temperature surveys, the study constructed lift gas performance curves for each well. Actual and optimum operating conditions were compared to determine the optimal gas lift. The study indicated a net 2,115 bo/d could be gained from implementing its recommendations.more » The actual net oil gained as a result of this optimization and injected gas reallocation was 2,024 bo/d. The paper discusses the Ramadan field, fluid properties, multiphase flow, production optimization, and results.« less

  20. Photogrammetric determination of discrepancies between actual and planned position of dental implants

    NASA Astrophysics Data System (ADS)

    Forlani, G.; Rivara, F.

    2014-05-01

    The paper describes the design and testing of a photogrammetric measurement protocol set up to determine the discrepancies between the planned and actual position of computer-guided template-based dental implants. Two moulds with the implants positioned in pre- and post- intervention are produced and separately imaged with a highly redundant block of convergent images; the model with the implants is positioned on a steel frame with control points and with suitable targets attached. The theoretical accuracy of the system is better than 20 micrometers and 0.3-0.4° respectively for positions of implants and directions of implant axes. In order to compare positions and angles between the planned and actual position of an implant, coordinates and axes directions are brought to a common reference system with a Helmert transformation. A procedure for comparison of positions and directions to identify out-of-tolerance discrepancies is presented; a numerical simulation study shows the effectiveness of the procedure in identifying the implants with significant discrepancies between pre- and post- intervention.