Sample records for additional blood samples

  1. Combinatorial Screening Of Inorganic And Organometallic Materials

    DOEpatents

    Li, Yi , Li, Jing , Britton, Ted W.

    2002-06-25

    A method for differentiating and enumerating nucleated red blood cells in a blood sample is described. The method includes the steps of lysing red blood cells of a blood sample with a lytic reagent, measuring nucleated blood cells by DC impedance measurement in a non-focused flow aperture, differentiating nucleated red blood cells from other cell types, and reporting nucleated red blood cells in the blood sample. The method further includes subtracting nucleated red blood cells and other interference materials from the count of remaining blood cells, and reporting a corrected white blood cell count of the blood sample. Additionally, the method further includes measuring spectrophotometric absorbance of the sample mixture at a predetermined wavelength of a hemoglobin chromogen formed upon lysing the blood sample, and reporting hemoglobin concentration of the blood sample.

  2. A micro-rheological method for determination of blood type.

    PubMed

    Makulska, Sylwia; Jakiela, Slawomir; Garstecki, Piotr

    2013-07-21

    The measurement of time and distance can be used for determining agglutination in small (nL) samples of liquid. We demonstrate the use of this new scheme of detection in typing and subtyping blood in a simple microfluidic system that monitors the speed of flow of microdroplets. The system (i) accepts small samples of liquids deposited directly onto the chip, (ii) forms droplets on demand from these samples, (iii) merges the droplets, and (iv) measures their speed in a microchannel. A sequence of measurements on different combinations of blood and antibodies can thus be used to determine blood type with the estimated probability of mistyping being less than 1 in a million tests. In addition, in the agglutinated samples, red blood cells concentrate at the rear of the droplets yielding an additional vista for detection and suggesting a possible mechanism for separations.

  3. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  4. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  5. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  6. Heat stabilization of blood spot samples for determination of metabolically unstable drug compounds

    PubMed Central

    Blessborn, Daniel; Sköld, Karl; Zeeberg, David; Kaewkhao, Karnrawee; Sköld, Olof; Ahnoff, Martin

    2014-01-01

    Background Sample stability is critical for accurate analysis of drug compounds in biosamples. The use of additives to eradicate the enzymatic activity causing loss of these analytes has its limitations. Results A novel technique for sample stabilization by rapid, high-temperature heating was used. The stability of six commercial drugs in blood and blood spots was investigated under various conditions with or without heat stabilization at 95°C. Oseltamivir, cefotaxime and ribavirin were successfully stabilized by heating whereas significant losses were seen in unheated samples. Amodiaquine was stable with and without heating. Artemether and dihydroartemisinin were found to be very heat sensitive and began to decompose even at 60°C. Conclusion Heat stabilization is a viable technique to maintain analytes in blood spot samples, without the use of chemical additives, by stopping the enzymatic activity that causes sample degradation. PMID:23256470

  7. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    PubMed

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.

  8. 21 CFR 660.36 - Samples and protocols.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... a cell panel intended for identification of unexpected antibodies. The sample shall be packaged as... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...

  9. Rapid and reliable determination of the halogenating peroxidase activity in blood samples.

    PubMed

    Flemmig, Jörg; Schwarz, Pauline; Bäcker, Ingo; Leichsenring, Anna; Lange, Franziska; Arnhold, Jürgen

    2014-12-15

    By combining easy and fast leukocyte enrichment with aminophenyl-fluorescein (APF) staining we developed a method to quickly and specifically address the halogenating activity of the immunological relevant blood heme peroxidases myeloperoxidase and eosinophil peroxidase, respectively. For leukocyte enrichment a two-fold hypotonic lysis procedure of the blood with Millipore water was chosen which represents a cheap, fast and reliable method to diminish the amount of erythrocytes in the samples. This procedure is shown to be suitable both to human and murine blood micro-samples, making it also applicable to small animal experiments with recurring blood sampling. As all types of leukocytes are kept in the sample during the preparation, they can be analysed separately after discrimination during the flow cytometry analysis. This also holds for all heme peroxidase-containing cells, namely neutrophils, eosinophils and monocytes. Moreover additional parameters (e.g. antibody staining) can be combined with the heme peroxidase activity determination to gain additional information about the different immune cell types. Based on previous results we applied APF for specifically addressing the halogenating activity of leukocyte peroxidases in blood samples. This dye is selectively oxidized by the MPO and EPO halogenation products hypochlorous and hypobromous acid. This approach may provide a suitable tool to gain more insights into the immune-physiological role of the halogenating activity of heme peroxidases. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Relationship between blood manganese and blood pressure in the Korean general population according to KNHANES 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Byung-Kook; Kim, Yangho, E-mail: yanghokm@nuri.net

    Introduction: We present data on the association of manganese (Mn) level with hypertension in a representative sample of the adult Korean population who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: This study was based on the data obtained by KNHANES 2008, which was conducted for three years (2007-2009) using a rolling sampling design involving a complex, stratified, multistage, probability-cluster survey of a representative sample of the noninstitutionalized civilian population of South Korea. Results: Multiple regression analysis after controlling for covariates, including gender, age, regional area, education level, smoking, drinking status, hemoglobin, and serum creatinine,more » showed that the beta coefficients of log blood Mn were 3.514, 1.878, and 2.517 for diastolic blood pressure, and 3.593, 2.449, and 2.440 for systolic blood pressure in female, male, and all participants, respectively. Multiple regression analysis including three other blood metals, lead, mercury, and cadmium, revealed no significant effects of the three metals on blood pressure and showed no effect on the association between blood Mn and blood pressure. In addition, doubling the blood Mn increased the risk of hypertension 1.828, 1.573, and 1.567 fold in women, men, and all participants, respectively, after adjustment for covariates. The addition of blood lead, mercury, and cadmium as covariates did not affect the association between blood Mn and the prevalence of hypertension. Conclusion: Blood Mn level was associated with an increased risk of hypertension in a representative sample of the Korean adult population. - Highlights: {yields} We showed the association of manganese with hypertension in Korean population. {yields} This study was based on the data obtained by KNHANES 2008. {yields} Blood manganese level was associated with an increased risk of hypertension.« less

  11. 21 CFR 640.23 - Testing the blood.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood...

  12. 21 CFR 640.23 - Testing the blood.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood...

  13. 21 CFR 640.23 - Testing the blood.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood...

  14. 21 CFR 640.23 - Testing the blood.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood...

  15. 21 CFR 640.23 - Testing the blood.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Testing the blood. 640.23 Section 640.23 Food and... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Platelets § 640.23 Testing the blood. (a) Blood from... this chapter and § 640.5 (a), (b), and (c). (b) The tests shall be performed on a sample of blood...

  16. Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations.

    PubMed

    Kang, Yang Jun; Ha, Young-Ran; Lee, Sang-Joon

    2016-01-07

    Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of subpopulations in RBCs.

  17. Isolating cells from female/male blood mixtures using florescence in situ hybridization combined with low volume PCR and its application in forensic science.

    PubMed

    Feng, Lei; Li, Cai-Xia; Han, Jun-Ping; Xu, Cheng; Hu, Lan

    2015-11-01

    To obtain single-source short tandem repeat (STR) profiles in trace female/male blood mixture samples, we combined florescence in situ hybridization (FISH), laser microdissection, and low volume PCR (LV-PCR) to isolate male/female cells and improve sensitivity. The results showed that isolation of as few as 10 leukocytes was sufficient to yield full STR profiles in fresh female or male blood samples for 32 independent tests with a low additional alleles rate (3.91%) and drop-out alleles rate (5.01%). Moreover, this procedure was tested in two fresh blood mixture series at three ratios (1:5, 1:10, and 1:20), two mock female/male blood mixture casework samples, and one practical casework sample. Male and female STR profiles were successfully detected in all of these samples, showing that this procedure could be used in forensic casework in the future.

  18. DNA methylation profiling for a confirmatory test for blood, saliva, semen, vaginal fluid and menstrual blood.

    PubMed

    Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin

    2016-09-01

    The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  20. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    PubMed Central

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  1. Silk-based blood stabilization for diagnostics.

    PubMed

    Kluge, Jonathan A; Li, Adrian B; Kahn, Brooke T; Michaud, Dominique S; Omenetto, Fiorenzo G; Kaplan, David L

    2016-05-24

    Advanced personalized medical diagnostics depend on the availability of high-quality biological samples. These are typically biofluids, such as blood, saliva, or urine; and their collection and storage is critical to obtain reliable results. Without proper temperature regulation, protein biomarkers in particular can degrade rapidly in blood samples, an effect that ultimately compromises the quality and reliability of laboratory tests. Here, we present the use of silk fibroin as a solid matrix to encapsulate blood analytes, protecting them from thermally induced damage that could be encountered during nonrefrigerated transportation or freeze-thaw cycles. Blood samples are recovered by simple dissolution of the silk matrix in water. This process is demonstrated to be compatible with a number of immunoassays and provides enhanced sample preservation in comparison with traditional air-drying paper approaches. Additional processing can remediate interactions with conformational structures of the silk protein to further enhance blood stabilization and recovery. This approach can provide expanded utility for remote collection of blood and other biospecimens empowering new modalities of temperature-independent remote diagnostics.

  2. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  3. Influence of blood sampling methods on dopamine-receptor-blocking activities as determined by a radioreceptor assay.

    PubMed

    Lai, A A; Fleck, R J; Patzke, J V; Glueck, B G; Shaskan, E G; Rosenberg, B J

    1982-01-01

    The influence of blood collection methods on dopamine-receptor-blocking activities as determined by a radioreceptor assay kit was investigated. Thirty-one patients treated with one of six neuroleptic drugs (thioridazine, trifluoperazine, haloperidol, chlorpromazine, thiothixene, or fluphenazine) participated in this study. Blood samples were drawn from each patient into five different evacuated blood collection tubes made by the same manufacturer (red-stoppered tube containing no additives, lavender-stoppered tube containing EDTA, green-stoppered tube containing heparin, dark blue-stoppered tube containing no additives, and dark blue-stoppered tube containing heparin). The results show that for five drugs (chlorpromazine, fluphenazine, haloperidol, thiothixene, and trifluoperazine), the dark blue-stoppered tubes without additives resulted in significantly higher dopamine-receptor-blocking activities than the red-, lavender-, or green-stoppered tubes. For thioridazine, the green-stoppered tubes resulted in significantly higher blocking activities than the blue- and red-stoppered tubes. The possible effect of tris(2-butoxyethyl) phosphate, a plasticizer, on dopamine-receptor-blocking activities by neuroleptic drugs is discussed.

  4. Induction of sister chromatid exchange in the presence of gadolinium-DTPA and its reduction by dimethyl sulfoxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamazaki, Etsuo; Fukuda, Hozumi; Shibuya, Hitoshi

    The authors investigate the frequency of sister chromatid exchange (SCE) after the addition of gadolinium (Gd)-DTPA to venous blood samples. Venous blood was obtained from nonsmokers. Samples were incubated with Gd-DTPA alone or in combination with mitomycin C, cytarabine, and dimethyl sulfoxide (DMSO), and then evaluated for SCEs. The frequency of SCE increased with the concentration of Gd-DTPA and as each chemotherapeutic agent was added. Sister chromatid exchange frequencies were lower when the blood was treated with a combination of Gd-DTPA and DMSO compared with Gd-DTPA alone. The increase in frequency of SCE seen after the addition of Gd-DTPA wasmore » decreased by the addition of DMSO, indicating the production of hydroxyl radicals. The effect likely is dissociation-related. 14 refs., 6 tabs.« less

  5. Detection of Merkel Cell Polyomavirus DNA in Serum Samples of Healthy Blood Donors

    PubMed Central

    Mazzoni, Elisa; Rotondo, John C.; Marracino, Luisa; Selvatici, Rita; Bononi, Ilaria; Torreggiani, Elena; Touzé, Antoine; Martini, Fernanda; Tognon, Mauro G.

    2017-01-01

    Merkel cell polyomavirus (MCPyV) has been detected in 80% of Merkel cell carcinomas (MCC). In the host, the MCPyV reservoir remains elusive. MCPyV DNA sequences were revealed in blood donor buffy coats. In this study, MCPyV DNA sequences were investigated in the sera (n = 190) of healthy blood donors. Two MCPyV DNA sequences, coding for the viral oncoprotein large T antigen (LT), were investigated using polymerase chain reaction (PCR) methods and DNA sequencing. Circulating MCPyV sequences were detected in sera with a prevalence of 2.6% (5/190), at low-DNA viral load, which is in the range of 1–4 and 1–5 copies/μl by real-time PCR and droplet digital PCR, respectively. DNA sequencing carried out in the five MCPyV-positive samples indicated that the two MCPyV LT sequences which were analyzed belong to the MKL-1 strain. Circulating MCPyV LT sequences are present in blood donor sera. MCPyV-positive samples from blood donors could represent a potential vehicle for MCPyV infection in receivers, whereas an increase in viral load may occur with multiple blood transfusions. In certain patient conditions, such as immune-depression/suppression, additional disease or old age, transfusion of MCPyV-positive samples could be an additional risk factor for MCC onset. PMID:29238698

  6. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  7. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  8. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  9. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  10. 21 CFR 640.92 - Tests on final product.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma Protein Fraction (Human) § 640.92 Tests on...) Heat stability. A final container sample of Plasma Protein Fraction (Human) shall remain unchanged, as...

  11. Maternal transfer of mercury to songbird eggs.

    PubMed

    Ackerman, Joshua T; Hartman, C Alex; Herzog, Mark P

    2017-11-01

    We evaluated the maternal transfer of mercury to eggs in songbirds, determined whether this relationship differed between songbird species, and developed equations for predicting mercury concentrations in eggs from maternal blood. We sampled blood and feathers from 44 house wren (Troglodytes aedon) and 34 tree swallow (Tachycineta bicolor) mothers and collected their full clutches (n = 476 eggs) within 3 days of clutch completion. Additionally, we sampled blood and feathers from 53 tree swallow mothers and randomly collected one egg from their clutches (n = 53 eggs) during mid to late incubation (6-10 days incubated) to evaluate whether the relationship varied with the timing of sampling the mother's blood. Mercury concentrations in eggs were positively correlated with mercury concentrations in maternal blood sampled at (1) the time of clutch completion for both house wrens (R 2  = 0.97) and tree swallows (R 2  = 0.97) and (2) during mid to late incubation for tree swallows (R 2  = 0.71). The relationship between mercury concentrations in eggs and maternal blood did not differ with the stage of incubation when maternal blood was sampled. Importantly, the proportion of mercury transferred from mothers to their eggs decreased substantially with increasing blood mercury concentrations in tree swallows, but increased slightly with increasing blood mercury concentrations in house wrens. Additionally, the proportion of mercury transferred to eggs at the same maternal blood mercury concentration differed between species. Specifically, tree swallow mothers transferred 17%-107% more mercury to their eggs than house wren mothers over the observed mercury concentrations in maternal blood (0.15-1.92 μg/g ww). In contrast, mercury concentrations in eggs were not correlated with those in maternal feathers and, likewise, mercury concentrations in maternal blood were not correlated with those in feathers (all R 2  < 0.01). We provide equations to translate mercury concentrations from maternal blood to eggs (and vice versa), which should facilitate comparisons among studies and help integrate toxicity benchmarks into a common tissue. Published by Elsevier Ltd.

  12. Maternal transfer of mercury to songbird eggs

    USGS Publications Warehouse

    Ackerman, Joshua T.; Hartman, C. Alex; Herzog, Mark

    2017-01-01

    We evaluated the maternal transfer of mercury to eggs in songbirds, determined whether this relationship differed between songbird species, and developed equations for predicting mercury concentrations in eggs from maternal blood. We sampled blood and feathers from 44 house wren (Troglodytes aedon) and 34 tree swallow (Tachycineta bicolor) mothers and collected their full clutches (n = 476 eggs) within 3 days of clutch completion. Additionally, we sampled blood and feathers from 53 tree swallow mothers and randomly collected one egg from their clutches (n = 53 eggs) during mid to late incubation (6–10 days incubated) to evaluate whether the relationship varied with the timing of sampling the mother's blood. Mercury concentrations in eggs were positively correlated with mercury concentrations in maternal blood sampled at (1) the time of clutch completion for both house wrens (R2 = 0.97) and tree swallows (R2 = 0.97) and (2) during mid to late incubation for tree swallows (R2 = 0.71). The relationship between mercury concentrations in eggs and maternal blood did not differ with the stage of incubation when maternal blood was sampled. Importantly, the proportion of mercury transferred from mothers to their eggs decreased substantially with increasing blood mercury concentrations in tree swallows, but increased slightly with increasing blood mercury concentrations in house wrens. Additionally, the proportion of mercury transferred to eggs at the same maternal blood mercury concentration differed between species. Specifically, tree swallow mothers transferred 17%–107% more mercury to their eggs than house wren mothers over the observed mercury concentrations in maternal blood (0.15–1.92 μg/g ww). In contrast, mercury concentrations in eggs were not correlated with those in maternal feathers and, likewise, mercury concentrations in maternal blood were not correlated with those in feathers (all R2 < 0.01). We provide equations to translate mercury concentrations from maternal blood to eggs (and vice versa), which should facilitate comparisons among studies and help integrate toxicity benchmarks into a common tissue.

  13. Quantitative Analysis of Therapeutic Drugs in Dried Blood Spot Samples by Paper Spray Mass Spectrometry: An Avenue to Therapeutic Drug Monitoring

    NASA Astrophysics Data System (ADS)

    Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham

    2011-09-01

    A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.

  14. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  15. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    NASA Astrophysics Data System (ADS)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  16. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    PubMed

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    PubMed

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  18. Algorithm-based arterial blood sampling recognition increasing safety in point-of-care diagnostics.

    PubMed

    Peter, Jörg; Klingert, Wilfried; Klingert, Kathrin; Thiel, Karolin; Wulff, Daniel; Königsrainer, Alfred; Rosenstiel, Wolfgang; Schenk, Martin

    2017-08-04

    To detect blood withdrawal for patients with arterial blood pressure monitoring to increase patient safety and provide better sample dating. Blood pressure information obtained from a patient monitor was fed as a real-time data stream to an experimental medical framework. This framework was connected to an analytical application which observes changes in systolic, diastolic and mean pressure to determine anomalies in the continuous data stream. Detection was based on an increased mean blood pressure caused by the closing of the withdrawal three-way tap and an absence of systolic and diastolic measurements during this manipulation. For evaluation of the proposed algorithm, measured data from animal studies in healthy pigs were used. Using this novel approach for processing real-time measurement data of arterial pressure monitoring, the exact time of blood withdrawal could be successfully detected retrospectively and in real-time. The algorithm was able to detect 422 of 434 (97%) blood withdrawals for blood gas analysis in the retrospective analysis of 7 study trials. Additionally, 64 sampling events for other procedures like laboratory and activated clotting time analyses were detected. The proposed algorithm achieved a sensitivity of 0.97, a precision of 0.96 and an F1 score of 0.97. Arterial blood pressure monitoring data can be used to perform an accurate identification of individual blood samplings in order to reduce sample mix-ups and thereby increase patient safety.

  19. Stability of carboxyhemoglobin in stored and mailed blood samples.

    PubMed

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  20. Geochemical survey of the Blood Mountain Roadless Area, Union and Lumpkin counties, Georgia

    USGS Publications Warehouse

    Koeppen, Robert P.; Nelson, Arthur E.

    1989-01-01

    The U.S. Geological Survey (USGS) made a reconnaissance geochemical survey of the Blood Mountain Roadless Area to search for unexposed mineral deposits which might be recognized by a geochemical signature in the abundance of distribution patterns of trace elements. Forty five fine-grained stream-sediment samples and 45 panned-concentrate samples were collected in the Blood Mountain study area (fig. 1). A.E. Nelson, in conjunction with detailed geologic mapping, collected 13 rock-chip samples for geochemical analysis, in addition to a large number of hand specimins for thin-section study. Nelson's geologic study (1983), combined with this geochemical survey, provide the basis for our mineral-resource assessment of the Blood Mountain Roadless Area (Koeppen and others, 1983).

  1. Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Todorov, T.I.; Xu, H.; Ejnik, J.W.; Mullick, F.G.; Squibb, K.; McDiarmid, M.A.; Centeno, J.A.

    2009-01-01

    In this study we report depleted uranium (DU) analysis in whole blood samples. Internal exposure to DU causes increased uranium levels as well as change in the uranium isotopic composition in blood specimen. For identification of DU exposure we used the 235U/238U ratio in blood samples, which ranges from 0.00725 for natural uranium to 0.002 for depleted uranium. Uranium quantification and isotopic composition analysis were performed by inductively coupled plasma mass spectrometry. For method validation we used eight spiked blood samples with known uranium concentrations and isotopic composition. The detection limit for quantification was determined to be 4 ng L-1 uranium in whole blood. The data reproduced within 1-5% RSD and an accuracy of 1-4%. In order to achieve a 235U/238U ratio range of 0.00698-0.00752% with 99.7% confidence limit a minimum whole blood uranium concentration of 60 ng L??1 was required. An additional 10 samples from a cohort of veterans exposed to DU in Gulf War I were analyzed with no knowledge of their medical history. The measured 235U/ 238U ratios in the blood samples were used to identify the presence or absence of DU exposure within this patient group. ?? 2009 The Royal Society of Chemistry.

  2. Riboflavin and ultraviolet light reduce the infectivity of Babesia microti in whole blood.

    PubMed

    Tonnetti, Laura; Thorp, Aaron M; Reddy, Heather L; Keil, Shawn D; Goodrich, Raymond P; Leiby, David A

    2013-04-01

    Babesia microti is the parasite most frequently transmitted by blood transfusion in the United States. Previous work demonstrated the efficacy of riboflavin (RB) and ultraviolet (UV) light to inactivate B.microti in apheresis plasma and platelet units. In this study we investigated the effectiveness of RB and UV light to reduce the levels of B.microti in whole blood (WB). WB units were spiked with B. microti-infected hamster blood. Spearman-Karber methods were used to calculate infectivity of each sample in terms of hamster infectious dose 50% (HID50 ) value. After RB addition, the units were illuminated with 80 J/mLRBC UV light. Two samples were collected: one before illumination and one after illumination. The samples were serially diluted and dilutions injected into a group of five naive hamsters. Four weeks postinoculation (PI), blood was collected from the animals and evaluated by microscopic observation. One pilot study showed a good dose response in the animals and demonstrated that sample infectivity could be calculated in terms of an HID50 . Three additional replicates were performed in the same manner as the pilot study, but with fewer dilutions. Infectivity values were consistent between the experiments and were used to calculate log reduction. The posttreatment reduction of B. microti for all the experiments was more than 5 log. The data collected indicate that use of RB and UV is able to decrease the parasite load in WB units thus reducing the risk of transfusion-transmitted B. microti from blood components containing B. microti-infected RBCs. © 2012 American Association of Blood Banks.

  3. Liquid biopsy - Performance of the PAXgene® Blood ccfDNA Tubes for the isolation and characterization of cell-free plasma DNA from tumor patients.

    PubMed

    Schmidt, Bernd; Reinicke, Dana; Reindl, Iris; Bork, Ines; Wollschläger, Bettina; Lambrecht, Nina; Fleischhacker, Michael

    2017-06-01

    In most research laboratories the use of EDTA tubes for the isolation of plasma DNA from tumor patients is standard. Unfortunately these tubes do not allow for an extended storage of samples before processing and prevent EDTA tubes from being shipped at ambient temperature. The aim of our study was to compare the quantity and quality of plasma DNA isolated from EDTA and PAXgene® Blood ccfDNA Tubes in different downstream applications. We enrolled 29 patients in our study. Blood samples were drawn into EDTA and PAXgene® Blood ccfDNA Tubes and were processed on day 0 and day 7 after storage at ambient temperature. The plasma DNA from 10 patients was isolated manually. For the DNA isolation from the plasma of 19 additional patients we used the automated QIAsymphony system. The total amount DNA from all samples was measured with a quantitative real-time PCR assay. In addition the amount of methylated mSHOX2 plasma DNA was determined. While the 7day storage lead to an increased amount of total DNA in almost all EDTA tubes, this effect was only seen in very few PAXgene® Blood ccfDNA Tubes. The stabilization solution which prevents the lysis of blood cells had no effect on the method for quantification of methylated sequences in these samples. The quantity and quality of plasma DNA from both types of blood draw tubes are comparable. DNA from PAXgene® Blood ccfDNA was successfully used for PCR-based quantification of total amount of cell-free DNA and for methylation analysis as well. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Methylation of Werner syndrome protein is associated with the occurrence and development of invasive meningioma via the regulation of Myc and p53 expression.

    PubMed

    Li, Puxian; Hao, Shuyu; Bi, Zhiyong; Zhang, Junting; Wu, Zhen; Ren, Xiaohui

    2015-08-01

    The aim of the present study was to investigate the positive rate of Werner syndrome protein (WRN) methylation in meningioma patients, and further assess the association between WRN methylation and the occurrence of meningioma. A total of 56 consecutive meningioma patients and 26 healthy individuals were enrolled in the study. A methylation-specific polymerase chain reaction assay was performed to detect the positive rate of WRN methylation in the peripheral blood and tissue samples collected from the recruited subjects. In addition, western blot analysis was performed to determine the protein expression levels of WRN, Myc and p53 in the peripheral blood and tissue samples. The positive rate of WRN methylation in the peripheral blood of the meningioma group was increased when compared with the control group (P<0.05). In addition, the protein expression levels of WRN were significantly decreased in the peripheral blood and tissue samples collected from the individuals with a positive WRN methylation status (P<0.05), as compared with the samples without WRN methylation. Furthermore, the protein expression levels of Myc and p53 were increased in the peripheral blood and tissue samples that exhibited positive WRN methylation when compared with those without WRN methylation (P<0.05). Therefore, WRN methylation was demonstrated to be associated with the occurrence and development of invasive meningioma, possibly through the regulation of Myc and p53 expression.

  5. Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations.

    PubMed

    Han, Ki-Ho; Frazier, A Bruno

    2006-02-01

    This paper presents the characterization of continuous single-stage and three-stage cascade paramagnetic capture (PMC) mode magnetophoretic microseparators for high efficiency separation of red and white blood cells from diluted whole blood based on their native magnetic properties. The separation mechanism for both PMC microseparators is based on a high gradient magnetic separation (HGMS) method. This approach enables separation of blood cells without the use of additives such as magnetic beads. Experimental results for the single-stage PMC microseparator show that 91.1% of red blood cells were continuously separated from the sample at a volumetric flow rate of 5 microl h-1. In addition, the three-stage cascade PMC microseparator continuously separated 93.5% of red blood cells and 97.4% of white blood cells from whole blood at a volumetric flow rate of 5 microl h-1.

  6. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    PubMed

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  8. Measurement of T1 of human arterial and venous blood at 7T.

    PubMed

    Rane, Swati D; Gore, John C

    2013-04-01

    Techniques for measuring cerebral perfusion require accurate longitudinal relaxation (T1) of blood, an MRI parameter that is field dependent. T1 of arterial and venous human blood was measured at 7T using three different sources - pathology laboratory, blood bank and in vivo. The T1 of venous blood was measured from sealed samples from a pathology lab and in vivo. Samples from a blood bank were oxygenated and mixed to obtain different physiological concentrations of hematocrit and oxygenation. T1 relaxation times were estimated using a three-point fit to a simple inversion recovery equation. At 37°C, the T1 of blood at arterial pO2 was 2.29±0.1s and 2.07±0.12 at venous pO2. The in vivo T1 of venous blood, in three subjects, was slightly longer at 2.45±0.11s. T1 of arterial and venous blood at 7T was measured and found to be significantly different. The T1 values were longer in vivo than in vitro. While the exact cause for the discrepancy is unknown, the additives in the blood samples, degradation during experiment, oxygenation differences, and the non-stagnant nature of blood in vivo could be potential contributors to the lower values of T1 in the venous samples. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.

    PubMed

    Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien

    2015-02-17

    Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

  10. Human Milk Oligosaccharides and Lewis Blood Group: Individual High-Throughput Sample Profiling to Enhance Conclusions From Functional Studies12

    PubMed Central

    Blank, Dennis; Dotz, Viktoria; Geyer, Rudolf; Kunz, Clemens

    2012-01-01

    Human milk oligosaccharides (HMO) are discussed to play a crucial role in an infant’s development. Lewis blood group epitopes, in particular, seem to remarkably contribute to the beneficial effects of HMO. In this regard, large-scale functional human studies could provide evidence of the variety of results from in vitro investigations, although increasing the amount and complexity of sample and data handling. Therefore, reliable screening approaches are needed. To predict the oligosaccharide pattern in milk, the routine serological Lewis blood group typing of blood samples can be applied due to the close relationship between the biosynthesis of HMO and the Lewis antigens on erythrocytes. However, the actual HMO profile of the individual samples does not necessarily correspond to the serological determinations. This review demonstrates the capabilities of merging the traditional serological Lewis blood group typing with the additional information provided by the comprehensive elucidation of individual HMO patterns by means of state-of-the-art analytics. Deduced from the association of the suggested HMO biosynthesis with the Lewis blood group, the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry profiles of oligosaccharides in individual milk samples exemplify the advantages and the limitations of sample assignment to distinct groups. PMID:22585923

  11. Detection of bacteraemias during non-surgicalroot canal treatment.

    PubMed

    Savarrio, L; Mackenzie, D; Riggio, M; Saunders, W P; Bagg, J

    2005-04-01

    Some dental procedures initiate a bacteraemia. In certain compromised patients, this bacteraemia may lead to distant site infections, most notably infective endocarditis. To investigate whether a detectable bacteraemia was produced during non-surgical root canal therapy. Thirty patients receiving non-surgical root canal therapy were studied. Three blood samples were taken per patient: pre-operatively, peri-operatively and post-operatively. In addition, a paper point sample was collected from the root canal. The blood samples were cultured by pour plate and blood bottle methods. The isolated organisms were identified by standard techniques. Blood samples were analysed for the presence of bacterial DNA by the polymerase chain reaction (PCR). In two cases where the same species of organism was identified in the root canal and the bloodstream, the isolates were typed by pulsed field gel electrophoresis (PFGE). By conventional culturing, a detectable bacteraemia was present in 9 (30%) of the 30 patients who had no positive pre-operative control blood sample. In 7 (23.3%) patients, the same species of organism was identified in both the bloodstream and in the paper point sample from the root canal system. Overall, PCR gave lower detection rates compared with conventional culture, with 10 of 90 (11%) of the blood samples displaying bacterial DNA. PFGE typing was undertaken for two pairs of culture isolates from blood and paper points; these were found to be genetically identical. Non-surgical root canal treatment may invoke a detectable bacteraemia.

  12. Maternal blood contamination of collected cord blood can be identified using DNA methylation at three CpGs.

    PubMed

    Morin, Alexander M; Gatev, Evan; McEwen, Lisa M; MacIsaac, Julia L; Lin, David T S; Koen, Nastassja; Czamara, Darina; Räikkönen, Katri; Zar, Heather J; Koenen, Karestan; Stein, Dan J; Kobor, Michael S; Jones, Meaghan J

    2017-01-01

    Cord blood is a commonly used tissue in environmental, genetic, and epigenetic population studies due to its ready availability and potential to inform on a sensitive period of human development. However, the introduction of maternal blood during labor or cross-contamination during sample collection may complicate downstream analyses. After discovering maternal contamination of cord blood in a cohort study of 150 neonates using Illumina 450K DNA methylation (DNAm) data, we used a combination of linear regression and random forest machine learning to create a DNAm-based screening method. We identified a panel of DNAm sites that could discriminate between contaminated and non-contaminated samples, then designed pyrosequencing assays to pre-screen DNA prior to being assayed on an array. Maternal contamination of cord blood was initially identified by unusual X chromosome DNA methylation patterns in 17 males. We utilized our DNAm panel to detect contaminated male samples and a proportional amount of female samples in the same cohort. We validated our DNAm screening method on an additional 189 sample cohort using both pyrosequencing and DNAm arrays, as well as 9 publically available cord blood 450K data sets. The rate of contamination varied from 0 to 10% within these studies, likely related to collection specific methods. Maternal blood can contaminate cord blood during sample collection at appreciable levels across multiple studies. We have identified a panel of markers that can be used to identify this contamination, either post hoc after DNAm arrays have been completed, or in advance using a targeted technique like pyrosequencing.

  13. One mouse, one pharmacokinetic profile: quantitative whole blood serial sampling for biotherapeutics.

    PubMed

    Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M

    2014-07-01

    The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.

  14. Partitioning behavior of heavy metals and persistent organic pollutants among feto-maternal bloods and tissues.

    PubMed

    Kim, Jun-Tae; Son, Min-Hui; Lee, Duk-Hee; Seong, Won Joon; Han, Seunghee; Chang, Yoon-Seok

    2015-06-16

    Heavy metals and persistent organic pollutants (POPs), including Pb, Cd, T-Hg, MeHg, PCDD/Fs, PCBs, PBDEs, PCNs, and PBDD/Fs, were analyzed in 20 paired samples of cord blood, maternal blood, maternal urine, and placenta. The samples were collected from pregnant mothers and neonates from South Korea in 2010. The distribution of heavy metals among the samples varied with their physicochemical characteristics. The concentrations of Pb and Hg in the maternal and the cord blood samples were significantly correlated each other, implying efficient transplacental transport (TPT). Cd and Hg were accumulated in the placenta, forming protein conjugates, and T-Hg was higher in the cord blood samples than the maternal blood samples due to the binding affinity of Hg with fetal proteins. POPs generally showed the highest concentrations in the maternal serum samples, and the POPs levels in the cord serum and the placenta samples were dependent on the degree of halogenation. The TPT of POPs was seemingly related to lipoprotein transportation. Some PBDE congeners, however, showed their highest concentrations in the cord serum samples, suggesting an additional TPT mechanism. This is the first study to detect PCNs and PBDD/Fs in the cord serum samples, showing that the PCN levels were comparable to other POPs. According to the principal component analysis (PCA) results of the contaminant levels, POPs and heavy metals showed significantly different characteristics, whereas PBDEs had an intermediate attribute. Despite the limited number of participants, the comprehensive analysis of trace contaminants in the paired sample sets enabled us to infer the distribution and TPT mechanism of various contaminants.

  15. Attitudes and Perceptions of Cancer Patients Toward Biospecimen Donation for Cancer Research: A Cross-Sectional Survey Among Chinese Cancer Patients.

    PubMed

    He, Na; Guo, Yan; He, Min; Qiang, Wanmin; Li, Haixin

    2017-08-01

    High-quality biospecimen collection from consented patients is crucial for cancer research activities. Patients' attitudes and willingness toward specimen donation influence high-quality biospecimen collection for cancer research activities. We carried out a cross-sectional study among randomly selected patients from 11 cancer departments of Tianjin Medical University Cancer Institute and Hospital between August 2014 and August 2015. A total of 784 patients were included to complete a 30-item self-administered survey. We evaluated the patients' willingness to consider providing leftover samples and additional samples for cancer research purposes. Among 784 patients, 683 (87.1%) and 653 (83.3%) were willing to donate leftover tissue and surplus blood after diagnosis, respectively. Six hundred thirty-one (80.5%) were favorably disposed to consider donating both tissue and blood samples for future cancer research. Female patients showed less willingness to donate biospecimens or related clinical data for research. First-hospitalized or older patients were less willing to provide leftover biospecimens or additional blood samples or even clinical data for research. By contrast, patients with a higher education level were more likely to donate leftover tissues after biopsy or surgery for research activities. Most Chinese cancer patients were willing to consider donating blood and tissue samples for cancer research. Several factors, including age, gender, first hospitalization, and education level, can influence their willingness to donate biospecimens. We need to provide proper education to increase understanding of patients in biobanking activities. This study provides novel empirical data on the likelihood of donating surplus and additional biospecimens and clinical health information among Chinese cancer patients.

  16. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study

    PubMed Central

    Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung

    2016-01-01

    Background To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. Objective In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. Methods We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants’ opinions regarding patient safety, timeliness, efficiency, and usability were recorded. Results In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Conclusions Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use. PMID:27784649

  17. Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study.

    PubMed

    Lee, Guna; Lee, Yura; Chong, Yong Pil; Jang, Seongsoo; Kim, Mi Na; Kim, Jeong Hoon; Kim, Woo Sung; Lee, Jae-Ho

    2016-10-26

    To evaluate patients with fever of unknown origin or those with suspected bacteremia, the precision of blood culture tests is critical. An inappropriate step in the test process or error in a parameter could lead to a false-positive result, which could then affect the direction of treatment in critical conditions. Mobile health apps can be used to resolve problems with blood culture tests, and such apps can hence ensure that point-of-care guidelines are followed and processes are monitored for blood culture tests. In this pilot project, we aimed to investigate the feasibility of using a mobile blood culture app to manage blood culture test quality. We implemented the app at a university hospital in South Korea to assess the potential for its utilization in a clinical environment by reviewing the usage data among a small group of users and by assessing their feedback and the data related to blood culture sampling. We used an iOS-based blood culture app that uses an embedded camera to scan the patient identification and sample number bar codes. A total of 4 medical interns working at 2 medical intensive care units (MICUs) participated in this project, which spanned 3 weeks. App usage and blood culture sampling parameters (including sampler, sampling site, sampling time, and sample volume) were analyzed. The compliance of sampling parameter entry was also measured. In addition, the participants' opinions regarding patient safety, timeliness, efficiency, and usability were recorded. In total, 356/644 (55.3%) of all blood culture samples obtained at the MICUs were examined using the app, including 254/356 (71.3%) with blood collection volumes of 5-7 mL and 256/356 (71.9%) with blood collection from the peripheral veins. The sampling volume differed among the participants. Sampling parameters were completely entered in 354/356 cases (99.4%). All the participants agreed that the app ensured good patient safety, disagreed on its timeliness, and did not believe that it was efficient. Although the bar code scanning speed was acceptable, the Wi-Fi environment required improvement. Moreover, the participants requested feedback regarding their sampling quality. Although this app could be used in the clinical setting, improvements in the app functions, environment network, and internal policy of blood culture testing are needed to ensure hospital-wide use.

  18. Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples.

    PubMed

    Nielsen, Betina Klint; Frederiksen, Tina; Friis-Hansen, Lennart; Larsen, Pia Bükmann

    2017-12-01

    Storage of blood samples after centrifugation, decapping and initial sampling allows ordering of additional blood tests. The pre-analytic stability of biochemistry and immunochemistry analytes has been studied in detail, but little is known about the post-analytical stability in incurred samples. We examined the stability of 23 routine analytes on the Dimension Vista® (Siemens Healthineers, Denmark): 42-60 routine samples in lithium-heparin gel tubes (Vacutainer, BD, USA) were centrifuged at 3000×g for 10min. Immediately after centrifugation, initial concentration of analytes were measured in duplicate (t=0). The tubes were stored decapped at room temperature and re-analyzed after 2, 4, 6, 8 and 10h in singletons. The concentration from reanalysis were normalized to initial concentration (t=0). Internal acceptance criteria for bias and total error were used to determine stability of each analyte. Additionally, evaporation from the decapped blood collection tubes and the residual platelet count in the plasma after centrifugation were quantified. We report a post-analytical stability of most routine analytes of ≥8h and do therefore - with few exceptions - suggest a standard 8hour-time limit for reordering and reanalysis of analytes in incurred samples. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Quantitative genetic analysis of the body composition and blood pressure association in two ethnically diverse populations.

    PubMed

    Ghosh, Sudipta; Dosaev, Tasbulat; Prakash, Jai; Livshits, Gregory

    2017-04-01

    The major aim of this study was to conduct comparative quantitative-genetic analysis of the body composition (BCP) and somatotype (STP) variation, as well as their correlations with blood pressure (BP) in two ethnically, culturally and geographically different populations: Santhal, indigenous ethnic group from India and Chuvash, indigenous population from Russia. Correspondently two pedigree-based samples were collected from 1,262 Santhal and1,558 Chuvash individuals, respectively. At the first stage of the study, descriptive statistics and a series of univariate regression analyses were calculated. Finally, multiple and multivariate regression (MMR) analyses, with BP measurements as dependent variables and age, sex, BCP and STP as independent variables were carried out in each sample separately. The significant and independent covariates of BP were identified and used for re-examination in pedigree-based variance decomposition analysis. Despite clear and significant differences between the populations in BCP/STP, both Santhal and Chuvash were found to be predominantly mesomorphic irrespective of their sex. According to MMR analyses variation of BP significantly depended on age and mesomorphic component in both samples, and in addition on sex, ectomorphy and fat mass index in Santhal and on fat free mass index in Chuvash samples, respectively. Additive genetic component contributes to a substantial proportion of blood pressure and body composition variance. Variance component analysis in addition to above mentioned results suggests that additive genetic factors influence BP and BCP/STP associations significantly. © 2017 Wiley Periodicals, Inc.

  20. Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

    PubMed

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-03-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.

  1. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    PubMed Central

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  2. Effect of storage conditions on the weight and appearance of dried blood spot samples on various cellulose-based substrates.

    PubMed

    Denniff, Philip; Spooner, Neil

    2010-11-01

    Before shipping and storage, dried blood spot (DBS) samples must be dried in order to protect the integrity of the spots. In this article, we examine the time required to dry blood spot samples and the effects of different environmental conditions on their integrity. Under ambient laboratory conditions, DBS samples on Whatman 903(®), FTA(®) and FTA(®) Elute substrates are dry within 90 min of spotting. An additional 5% of moisture is lost during subsequent storage with desiccant. When exposed to elevated conditions of temperature and relative humidity, the DBS samples absorb moisture. DBS samples on FTA lose this moisture on being returned to ambient conditions. DBS samples on 903 show no visible signs of deterioration when stored at elevated conditions. However, these conditions cause the DBS to diffuse through the FTA Elute substrate. Blood spots are dry within 90 min of spotting. However, the substrates examined behave differently when exposed to conditions of high relative humidity and temperature, in some cases resulting in the integrity of the substrate and DBS sample being compromised. It is recommended that these factors be investigated as part of method development and validation.

  3. A screening method for biotinidase deficiency in newborns.

    PubMed

    Heard, G S; Secor McVoy, J R; Wolf, B

    1984-01-01

    We describe a method for neonatal screening for biotinidase (EC 3.5.1.12) deficiency. Biotinidase activity is assessed colorimetrically from dried samples of whole blood spotted on the same filter papers as used in the neonatal screening for phenylketonuria. After the reaction, samples from normal infants are characteristically purple, whereas those from affected individuals are straw-colored. To confirm the deficiency, the enzyme is quantitatively assayed in additional blood spots or serum. A pilot study has been initiated with samples obtained by the Commonwealth of Virginia for phenylketonuria testing.

  4. [Study on the reproducibility of ACTH concentrations in plasma of horses with and without equine Cushing syndrome].

    PubMed

    Gehlen, Heidrun; Bradaric, Zrinkja

    2013-01-01

    The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.

  5. Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples

    NASA Astrophysics Data System (ADS)

    Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.; Sánchez-Gómez, R.

    2008-08-01

    The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.

  6. Correlation between Na/K ratio and electron densities in blood samples of breast cancer patients.

    PubMed

    Topdağı, Ömer; Toker, Ozan; Bakırdere, Sezgin; Bursalıoğlu, Ertuğrul Osman; Öz, Ersoy; Eyecioğlu, Önder; Demir, Mustafa; İçelli, Orhan

    2018-05-31

    The main purpose of this study was to investigate the relationship between the electron densities and Na/K ratio which has important role in breast cancer disease. Determinations of sodium and potassium concentrations in blood samples performed with inductive coupled plasma-atomic emission spectrometry. Electron density values of blood samples were determined via ZXCOM. Statistical analyses were performed for electron densities and Na/K ratio including Kolmogorov-Smirnov normality tests, Spearman's rank correlation test and Mann-Whitney U test. It was found that the electron densities significantly differ between control and breast cancer groups. In addition, statistically significant positive correlation was found between the electron density and Na/K ratios in breast cancer group.

  7. Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system.

    PubMed

    Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji

    2013-01-01

    To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI) was determined using IG-AUC and reference AUC measured by blood sampling. IG-AUC strongly correlated with reference AUC (R = 0.91), and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88). IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.

  8. Primary prevention of pediatric lead exposure requires new approaches to transfusion screening.

    PubMed

    Gehrie, Eric; Keiser, Amaris; Dawling, Sheila; Travis, James; Strathmann, Frederick G; Booth, Garrett S

    2013-09-01

    To facilitate further assessment of transfusion-associated lead exposure by designing a procedure to test packed red blood cells (pRBCs) prepared for transfusion. The relationship between pRBCs and whole blood lead concentration was investigated in 27 samples using a modified clinical assay. Lead concentrations were measured in 100 pRBC units. Our sample preparation method demonstrated a correlation between whole blood lead and pRBC lead concentrations (R(2) = 0.82). In addition, all 100 pRBC units tested had detectable lead levels. The median pRBC lead concentration was 0.8 μg/dL, with an SD of 0.8 μg/dL and a range of 0.2-4.1 μg/dL. In addition, after only a few days of storage, approximately 25% of whole blood lead was found in the supernatant plasma. Transfusion of pRBCs is a source of lead exposure. Here we report the quantification of lead concentration in pRBCs. We found a >20-fold range of lead concentrations in the samples tested. Pretransfusion testing of pRBC units according to our proposed approach or donor screening of whole blood lead and selection of below-average units for transfusion to children would diminish an easily overlooked source of pediatric lead exposure. Copyright © 2013 Mosby, Inc. All rights reserved.

  9. [Cross-sectional study on high-normal blood pressure and chronic kidney disease in occupational physical examination population in Changsha].

    PubMed

    Cao, Xia; Xie, Xiumei; Xu, Guo; Yuan, Hong; Chen, Zhiheng

    2014-06-01

    To investigate the relationship between high-normal blood pressure and chronic kidney disease (CKD) in occupational physical examination population in Changsha. With a convenient sampling method, a cross-sectional survey of representative sample of 11 274 white collar workers was conducted in Changsha between March 2011 and May 2011 in a large comprehensive hospital. All subjects were assigned into 4 groups: a normal blood pressure group, a high-normal blood pressure group, an undiagnosed hypertension group, and a diagnosed hypertension group. Anthropometry, blood pressure, blood sample and urine sample were measured with standard instruments and methodology for all the subjects. Multiple logistic regression analysis was used to identify risk factors for CKD. The prevalence of CKD in the normal blood pressure, high-normal blood pressure, undiagnosed hypertension, and diagnosed hypertension were 3.31%, 6.60%, 11.78%, and 17.35%, respectively. The prevalence of CKD in males was significantly higher than that in females (P<0.01). For males with high-normal blood pressure, the CKD risk was significantly greater (OR, 1.30; 95% CI:1.03 - 1.63) than those with optimal blood pressure. The logistic regression analysis showed that there was an additive effect of hyperuricemia on CKD risk in men with high-normal blood pressure compared with men with optimal blood pressure (OR, 2.25; 95% CI, 1.59 - 3.19; P<0.05). The prevalence of CKD in people with the high-normal blood pressure is 6.60% in occupational physical examination population in Changsha. CKD is a high risk for men with highnormal blood pressure and hyperuricemia is an independent risk factor.

  10. Quantification of Rifapentine, a Potent Antituberculosis Drug, from Dried Blood Spot Samples Using Liquid Chromatographic-Tandem Mass Spectrometric Analysis

    PubMed Central

    Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.

    2014-01-01

    The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637

  11. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  12. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE PAGES

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-04-07

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  13. A strategical re-thinking on National Blood Donor Pool: Anti-HBc positivity related re-entry mechanisms.

    PubMed

    Yilmaz, Soner; Unlu, Aytekin; Cetinkaya, Riza Aytac; Yapar, Mehmet; Avci, Ismail Yasar; Yilmaz, Sebahattin; Eyigun, Can Polat

    2016-04-01

    Screening of blood donations for antibodies against hepatitis B core antigen (anti-HBc) is used to prevent transfusion transmitted hepatitis B virus (HBV) infection. In this study, we studied the magnitude of blood donor gain by using a re-entry mechanism in our Blood Bank of Gulhane Military Academy of Medicine. Between January and May 2013, 5148 voluntary blood donors were screened by ELISA method for HBsAg, anti-HBc total and other screening markers, prospectively. Samples with repeated reactivity for the presence of anti-HBc were further tested with four supplemental assays. We detected 515 (10%) anti-HBc positive and 4612 (90%) anti-HBc negative cases in 5127 HBsAg negative serum samples. A total of 461 (89.5%) blood units were reactive for at least one additional serologic parameter and 54 were (10.5%) negative. Isolated anti-HBc positivity rate was 1.3% (69/5127). In the isolated anti-HBc positive samples, 54 were also anti-HBe and HBeAg negative. HBV DNA was not detected in any of the samples. Applying the EDQM criteria would decrease our blood donor loss from 10% to 5.4%. As alternative re-entry mechanisms have already been presented in the literature, institution of a new policy is needed to enhance the limited blood donor pool in our system. Copyright © 2016. Published by Elsevier Ltd.

  14. Expression in Whole Blood Samples of miRNA-191 and miRNA-455-3p in Patients with AAA and Their Relationship to Clinical Outcomes after Endovascular Repair.

    PubMed

    Tenorio, Emanuel Junio Ramos; Braga, Andre Felipe Farias; Tirapelli, Daniela Pretti Da Cunha; Ribeiro, Mauricio Serra; Piccinato, Carlos Eli; Joviliano, Edwaldo Edner

    2018-03-05

    The purpose of this study was to quantify and evaluate the expression response of miRNA-191 and miRNA-455-3p endovascular repair of abdominal aortic aneurysm (AAA) based in whole blood samples. This report describes a prospective study of a single center of 30 patients with AAA who underwent endovascular repair. Blood samples were collected preoperatively and 6 months postoperatively. The differential expression of the miRNAs was performed by the real-time polymerase chain reaction method, after extraction of the RNA from the blood samples at the 2 moments. In addition, bioinformatic tools were used to determine pathophysiological pathways related to AAA. The miR-191 and miR-455-3p were overexpressed preoperatively. After 6 months postoperatively, miR-191 (median 0.98, IQR 0.5-2.1, P < 0.0001) and miR-455-3p (median 1.4, IQR 0.6-3.1, P = 0.0003) presented a significant reduction in their expressions. There was no correlation between the diameter of the aneurysm and the expression of the miRNAs studied. In addition, analysis of the influence of the various types of devices used for the endovascular treatment of AAA showed no significant differences in the expression of miR-191 and miR-455-3p. Exclusion of the aneurysmal sac after endovascular treatment induces a decrease in the expression of the studied miRNAs in whole blood samples, which suggests a possible use of them as biomarkers of therapeutic success. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Effective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium salt

    PubMed Central

    Schuff-Werner, Peter; Steiner, Michael; Fenger, Sebastian; Gross, Hans-Jürgen; Bierlich, Alexa; Dreissiger, Katrin; Mannuß, Steffen; Siegert, Gabriele; Bachem, Maximilian; Kohlschein, Peter

    2013-01-01

    Pseudothrombocytopenia remains a challenge in the haematological laboratory. The pre-analytical problem that platelets tend to easily aggregate in vitro, giving rise to lower platelet counts, has been known since ethylenediamine-tetra acetic acid EDTA and automated platelet counting procedures were introduced in the haematological laboratory. Different approaches to avoid the time and temperature dependent in vitro aggregation of platelets in the presence of EDTA were tested, but none of them proved optimal for routine purposes. Patients with unexpectedly low platelet counts or flagged for suspected aggregates, were selected and smears were examined for platelet aggregates. In these cases patients were asked to consent to the drawing of an additional sample of blood anti-coagulated with a magnesium additive. Magnesium was used in the beginning of the last century as anticoagulant for microscopic platelet counts. Using this approach, we documented 44 patients with pseudothrombocytopenia. In all cases, platelet counts were markedly higher in samples anti-coagulated with the magnesium containing anticoagulant when compared to EDTA-anticoagulated blood samples. We conclude that in patients with known or suspected pseudothrombocytopenia the magnesium-anticoagulant blood samples may be recommended for platelet counting. PMID:23808903

  16. T2 Magnetic Resonance Assay-Based Direct Detection of Three Lyme Disease-Related Borrelia Species in Whole-Blood Samples.

    PubMed

    Snyder, Jessica L; Giese, Heidi; Bandoski-Gralinski, Cheryl; Townsend, Jessica; Jacobson, Beck E; Shivers, Robert; Schotthoefer, Anna M; Fritsche, Thomas R; Green, Clayton; Callister, Steven M; Branda, John A; Lowery, Thomas J

    2017-08-01

    In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii Clinical samples ( n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples. Copyright © 2017 American Society for Microbiology.

  17. T2 Magnetic Resonance Assay-Based Direct Detection of Three Lyme Disease-Related Borrelia Species in Whole-Blood Samples

    PubMed Central

    Giese, Heidi; Bandoski-Gralinski, Cheryl; Townsend, Jessica; Jacobson, Beck E.; Shivers, Robert; Schotthoefer, Anna M.; Fritsche, Thomas R.; Green, Clayton; Callister, Steven M.; Branda, John A.

    2017-01-01

    ABSTRACT In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii. Clinical samples (n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples. PMID:28566314

  18. Distinct Gene Expression Patterns between Nasal Mucosal Cells and Blood Collected from Allergic Rhinitis Sufferers.

    PubMed

    Watts, Annabelle M; West, Nicholas P; Cripps, Allan W; Smith, Pete K; Cox, Amanda J

    2018-06-19

    Investigations of gene expression in allergic rhinitis (AR) typically rely on invasive nasal biopsies (site of inflammation) or blood samples (systemic immunity) to obtain sufficient genetic material for analysis. New methodologies to circumvent the need for invasive sample collection offer promise to further the understanding of local immune mechanisms relevant in AR. A within-subject design was employed to compare immune gene expression profiles obtained from nasal washing/brushing and whole blood samples collected during peak pollen season. Twelve adults (age: 46.3 ± 12.3 years) with more than a 2-year history of AR and a confirmed grass pollen allergy participated in the study. Gene expression analysis was performed using a panel of 760 immune genes with the NanoString nCounter platform on nasal lavage/brushing cell lysates and compared to RNA extracted from blood. A total of 355 genes were significantly differentially expressed between sample types (9.87 to -9.71 log2 fold change). The top 3 genes significantly upregulated in nasal lysate samples were Mucin 1 (MUC1), Tight Junction Protein 1 (TJP1), and Lipocalin-2 (LCN2). The top 3 genes significantly upregulated in blood samples were cluster of differentiation 3e (CD3E), FYN Proto-Oncogene Src Family Tyrosine Kinase (FYN) and cluster of differentiation 3d (CD3D). Overall, the blood and nasal lavage samples showed vastly distinct gene expression profiles and functional gene pathways which reflect their anatomical and functional origins. Evaluating immune gene expression of the nasal mucosa in addition to blood samples may be beneficial in understanding AR pathophysiology and response to allergen challenge. © 2018 S. Karger AG, Basel.

  19. The combination of recombinant factor VIIa and fibrinogen correct clotting ex vivo in patient samples obtained following cardiopulmonary bypass surgery.

    PubMed

    Sørensen, Benny; Asvaldsdottir, Hanna S; Gudmundsdottir, Brynja R; Onundarson, Pall T

    2009-12-01

    Cardiac surgery involving cardio pulmonary bypass (CPB) may be associated with development of a coagulopathy that increases risk of bleeding. In the present ex vivo study we investigated the influence of fibrinogen and rFVIIa, alone or in combination, on whole blood coagulation thromboelastometry using pre- and postoperative blood samples from 18 consecutive adult patients undergoing CPB surgery. Dynamic thromboelastometric clotting profiles were recorded using citrated whole blood activated with trace amounts of tissue factor (Innovin, final dilution 1:17000). Blood samples were collected before surgery (control) and postoperative samples were obtained following in vivo neutralization of heparin with protamine sulphate. All blood samples were treated with heparinase to ensure neutralization of possible residual heparin effect. The post-operative blood samples were spiked with buffer, rFVIIa (2 microg/mL), fibrinogen (1 mg/mL), or the combination of rFVIIa and fibrinogen. Despite neutralization of heparin, CPB surgery left a measurable coagulopathy that was thromboelastometrically characterized by prolonged onset of clotting, reduced maximum velocity of clot formation (MaxVel), and decreased maximum clot firmness (MCF). Ex vivo spiking of the postoperative samples with rFVIIa shortened the clotting time. Fibrinogen also shortened the clotting time and, in addition, improved the MaxVel, and MCF. Finally, adding the combination of rFVIIa and fibrinogen to the postoperative samples corrected all thromboelastometric parameters to the preoperative range. In conclusion, the correction of whole blood clotting abnormalities that occurs with rFVIIa and/or fibrinogen suggests that future clinical trials on treatment of bleeding during CPB surgery should study the haemostatic effect of fibrinogen or possibly the combination of rFVIIa and fibrinogen.

  20. Effects of monosodium glutamate (umami taste) with and without guanosine 5'-monophosphate on rat autonomic responses to meals.

    PubMed

    Steffens, A B; Leuvenink, H; Scheurink, A J

    1994-07-01

    Monosodium glutamate (MSG) is used as a food additive to improve the taste of food. The effect of MSG on sweet taste is enhanced by guanosine 5'-monophosphate (GMP). Because increased palatability is known to increase the vagally mediated preabsorptive insulin response (PIR), we hypothesized that MSG and GMP will enhance the PIR. To study this, male Wistar rats were provided with permanent cannulas for venous blood sampling and intragastric drug administration. The MSG and GMP were either added to a test meal or infused into the stomach during a test meal. Blood samples were taken to measure concentrations of glucose, insulin, epinephrine (E), and norepinephrine (NE). Addition of 56 mg MSG to a control meal markedly reduced both phases of the meal-induced increase in plasma insulin and had no effects on blood glucose and plasma E and NE responses. Infusion of 56 mg MSG into the stomach at the onset of food intake reduced the PIR with no effect on glucose, E, NE, or the second phase insulin release. Addition of 2 mg MSG in combination with GMP to the test meal or gastric administration of these drugs did not affect the changes in any of the blood components measured. It is concluded that addition of a high dose of MSG to a test meal leads to a reduction in the vagal response to food.

  1. Phase 0 Trial of Itraconazole for Early-Stage Non-Small Cell Lung Cancer

    DTIC Science & Technology

    2016-10-01

    tissue and blood sampling in addition to magnetic resonance imaging ( MRI ) scans for biomarker analysis. At the time of surgery, resected tissue will...original proposal, these subjects underwent study-related MRI scans, skin biopsies, blood tests, treatment with itraconazole, and surgical resection...not complete serial MRIs scans. Task 2: Determine anti-angiogenic effects of itraconazole Subtask 2a: Blood-based PD studies As described in the

  2. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry.

    PubMed

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group.

  3. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.

    PubMed

    Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario

    2013-11-01

    Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.

  4. Dose Responses of Ibuprofen In Vitro on Platelet Aggregation and Coagulation in Human and Pig Blood Samples.

    PubMed

    Martini, Wenjun Z; Rodriguez, Cassandra M; Deguzman, Rodolfo; Guerra, Jessica B; Martin, Angela K; Pusateri, Anthony E; Cap, Andrew P; Dubick, Michael A

    2016-05-01

    Ibuprofen is commonly used by warfighters in the deployed environment. This study investigated its dose effects on in vitro coagulation in human and pig blood. Blood samples were collected from 6 normal volunteers and 6 healthy pigs and processed to make platelet-adjusted samples (100 × 10(3)/μL, common transfusion trigger in trauma). Ibuprofen was added to the samples at concentrations of 0 μg/mL (control), the concentration from the highest recommended oral dose (163 μg/mL, 1×), and 2×, 4×, 8×, 10×, 12×, 16×, and 20×. Platelet aggregation by Chrono-Log aggregometer and coagulation by rotational thrombelastogram (Rotem) were assessed at 15 minutes after the addition of ibuprofen. A robust inhibition of ibuprofen on arachidonic acid-induced platelet aggregation was observed at all doses tested in human or pig blood. Collagen-stimulated platelet aggregation was inhibited starting at 1× in human blood and 4× in pig blood. Rotem measurements were similarly compromised in pig and human blood starting at 16×, except clot formation time was prolonged at 1× in human blood (all p < 0.05). Ibuprofen inhibited platelet aggregation at recommended doses, and compromised coagulation at higher doses. Human blood was more sensitive to ibuprofen inhibition. Further effort is needed to investigate ibuprofen dose responses on coagulation in vivo. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  5. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode

    NASA Astrophysics Data System (ADS)

    Zhao, Zuomin; Myllylae, Risto A.

    2001-06-01

    The near-infrared photoacoustic technique is recognized as a potential method for the non-invasive determination of human glucose, because near-infrared light can incident a few millimeters into human tissue, where it produces an acoustic wave capable of carrying information about the composition of the tissue. This paper demonstrates a photoacoustic glucose measurement in a blood sample as a step toward a non-invasive measurement. The experimental apparatus consists of a near-infrared laser diode operating with 4 micro joules pulse energy at 905 nm, a roller pump connected to a silicon plastic tube and a cuvette for circulating the blood sample. In addition, the apparatus comprises a PZT piezoelectric transducer integrated with a battery-powered preamplifier to receive the photoacoustic signal. During the experiment, a glucose solution is mixed into a human blood sample to change its concentration. Although the absorption coefficient of glucose is much smaller than that of blood in the near-infrared region, the osmotic and hydrophilic properties of glucose decrease the reduced scattering coefficient of blood caused by the dissolved glucose surrounding the blood cells. This changes the distribution of the absorbed optical energy in blood, which, in turn, produces a change in the photoacoustic signal. Our experiment demonstrates that signal amplitudes in fresh and stored blood samples in crease about 7% and 10%, respectively, when the glucose concentration reaches the upper limit of the physiological region (500 mg/dl).

  6. Glycosyltransferases as marker genes for the quantitative polymerase chain reaction-based detection of circulating tumour cells from blood samples of patients with breast cancer undergoing adjuvant therapy.

    PubMed

    Kölbl, Alexandra C; Hiller, Roman A; Ilmer, Mathias; Liesche, Friederike; Heublein, Sabine; Schröder, Lennard; Hutter, Stefan; Friese, Klaus; Jeschke, Udo; Andergassen, Ulrich

    2015-08-01

    Altered glycosylation is a predominant feature of tumour cells; it serves for cell adhesion and detachment, respectively, and facilitates the immune escape of these cells. Therefore changes in the expression of glycosyltransferase genes could help to identify circulating tumour cells (CTCs) in the blood samples of cancer patients using a quantitative polymerase chain reaction (PCR) approach. Blood samples of healthy donors were inoculated with certain numbers of established breast cancer cell line cells, thus creating a model system. These samples were analysed by quantitative PCR for the expression of six different glycosyltransferase genes. The three genes with the best results in the model system were consecutively applied to samples from adjuvant breast cancer patients and of healthy donors. FUT3 and GALNT6 showed the highest increase in relative expression, while GALNT6 and ST3GAL3 were the first to reach statistically significant different ∆CT-values comparing the sample with and without addition of tumour cells. These three genes were applied to patient samples, but did not show any significant results that may suggest the presence of CTCs in the blood. Although the relative expression of some of the glycosyltransferase genes exhibited reasonable results in the model system, their application to breast cancer patient samples will have to be further improved, e.g. by co-analysis of patient blood samples by gold-standard methods.

  7. Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results.

    PubMed

    Iwersen, M; Klein-Jöbstl, D; Pichler, M; Roland, L; Fidlschuster, B; Schwendenwein, I; Drillich, M

    2013-01-01

    The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring β-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement procedures. Storage temperature of the devices and test strips did not influence the differences between the results of the laboratory and the devices, whereas the temperature of the blood samples caused significant differences. Although the level of agreement between the laboratory and the GLX device was lower than for the laboratory and the FSP device, both devices are useful tools for monitoring subclinical ketosis in dairy cows. Due to their effects on the determined results, the type and temperature of the tested sample should be considered. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Organic selenium supplementation increased selenium concentrations in ewe and newborn lamb blood and in slaughter lamb meat compared to inorganic selenium supplementation.

    PubMed

    Steen, Arvid; Strøm, Turid; Bernhoft, Aksel

    2008-03-31

    Selenium is part of the antioxidant defence system in animals and humans. The available selenium concentration in soil is low in many regions of the world. The purpose of this study was to evaluate the effect of organic versus inorganic selenium supplementation on selenium status of ewes, their lambs, and slaughter lambs. Ewes on four organic farms were allocated five or six to 18 pens. The ewes were given either 20 mg/kg inorganic selenium as sodium selenite or organic selenium as selenized nonviable yeast supplementation for the two last months of pregnancy. Stipulated selenium concentrations in the rations were below 0.40 mg/kg dry matter. In addition 20 male lambs were given supplements from November until they were slaughtered in March. Silage, hay, concentrates, and individual ewe blood samples were taken before and after the mineral supplementation period, and blood samples were taken from the newborn lambs. Blood samples from ewes and lambs in the same pens were pooled. Muscle samples were taken from slaughter lambs in March. Selenium concentrations were determined by atomic absorption spectrometry with a hydride generator system. In the ANOVA model, selenium concentration was the continuous response variable, and selenium source and farm were the nominal effect variables. Two-sample t-test was used to compare selenium concentrations in muscle samples from the slaughtered lambs that received either organic or inorganic selenium supplements. In all ewe pens the whole blood selenium concentrations increased during the experimental period. In addition, ewe pens that received organic selenium had significantly higher whole blood selenium concentrations (mean 0.28 microg/g) than ewe pens that received inorganic selenium (mean 0.24 microg/g). Most prominent, however, was the difference in their lambs; whole blood mean selenium concentration in lambs from mothers that received organic selenium (mean 0.27 microg/g) was 30% higher than in lambs from mothers that received inorganic selenium (mean 0.21 microg/g). Slaughter lambs that received organic selenium had 50% higher meat selenium concentrations (mean 0.12 mg/kg wet weight) than lambs that received inorganic selenium (mean 0.08 mg/kg wet weight). Organic selenium supplementation gave higher selenium concentration in ewe and newborn lamb blood and slaughter lamb meat than inorganic selenium supplementation.

  9. Organic selenium supplementation increased selenium concentrations in ewe and newborn lamb blood and in slaughter lamb meat compared to inorganic selenium supplementation

    PubMed Central

    Steen, Arvid; Strøm, Turid; Bernhoft, Aksel

    2008-01-01

    Background Selenium is part of the antioxidant defence system in animals and humans. The available selenium concentration in soil is low in many regions of the world. The purpose of this study was to evaluate the effect of organic versus inorganic selenium supplementation on selenium status of ewes, their lambs, and slaughter lambs. Methods Ewes on four organic farms were allocated five or six to 18 pens. The ewes were given either 20 mg/kg inorganic selenium as sodium selenite or organic selenium as selenized nonviable yeast supplementation for the two last months of pregnancy. Stipulated selenium concentrations in the rations were below 0.40 mg/kg dry matter. In addition 20 male lambs were given supplements from November until they were slaughtered in March. Silage, hay, concentrates, and individual ewe blood samples were taken before and after the mineral supplementation period, and blood samples were taken from the newborn lambs. Blood samples from ewes and lambs in the same pens were pooled. Muscle samples were taken from slaughter lambs in March. Selenium concentrations were determined by atomic absorption spectrometry with a hydride generator system. In the ANOVA model, selenium concentration was the continuous response variable, and selenium source and farm were the nominal effect variables. Two-sample t-test was used to compare selenium concentrations in muscle samples from the slaughtered lambs that received either organic or inorganic selenium supplements. Results In all ewe pens the whole blood selenium concentrations increased during the experimental period. In addition, ewe pens that received organic selenium had significantly higher whole blood selenium concentrations (mean 0.28 μg/g) than ewe pens that received inorganic selenium (mean 0.24 μg/g). Most prominent, however, was the difference in their lambs; whole blood mean selenium concentration in lambs from mothers that received organic selenium (mean 0.27 μg/g) was 30% higher than in lambs from mothers that received inorganic selenium (mean 0.21 μg/g). Slaughter lambs that received organic selenium had 50% higher meat selenium concentrations (mean 0.12 mg/kg wet weight) than lambs that received inorganic selenium (mean 0.08 mg/kg wet weight). Conclusion Organic selenium supplementation gave higher selenium concentration in ewe and newborn lamb blood and slaughter lamb meat than inorganic selenium supplementation. PMID:18377659

  10. Preanalytical considerations in detection of colorectal cancer in blood serum using Raman molecular imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Treado, Patrick J.; Stewart, Shona D.; Smith, Aaron; Kirschner, Heather; Post, Christopher; Overholt, Bergein F.

    2016-03-01

    Colorectal cancer (CRC) is the third most common cancer in men and women in the United States. Raman Molecular Imaging (RMI) is an effective technique to evaluate human tissue, cells and bodily fluids, including blood serum for disease diagnosis. ChemImage Corporation, in collaboration with clinicians, has been engaged in development of an in vitro diagnostic Raman assay focused on CRC detection. The Raman Assay for Colorectal Cancer (RACC) exploits the high specificity of Raman imaging to distinguish diseased from normal dried blood serum droplets without additional reagents. Pilot Study results from testing of hundreds of biobank patient samples have demonstrated that RACC detects CRC with high sensitivity and specificity. However, expanded clinical trials, which are ongoing, are revealing a host of important preanalytical considerations associated with sample collection, sample storage and stability, sample shipping, sample preparation and sample interferents, which impact detection performance. Results from recent clinical studies will be presented.

  11. Institutional practices and policies in acid-base testing: a self reported Croatian survey study on behalf of the Croatian society of medical biochemistry and laboratory medicine Working Group for acid-base balance.

    PubMed

    Dukić, Lora; Simundić, Ana-Maria

    2014-01-01

    The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.

  12. Near Infrared Optical Properties of Whole Human Blood and Blood Containing Nanoparticulates

    NASA Astrophysics Data System (ADS)

    Mimun, Lawrence C.; Yust, Brian; Nash, Kelly L.; Sardar, Dhiraj K.

    2010-10-01

    Whole human blood is optically characterized in the near infrared (NIR) with and without the addition of nanocrystals. The optical properties were obtained using the double-integrating sphere technique at the Nd excitation wavelength of 808 nm. Y2O3 and Nd^3+:Y2O3 nanoparticles were added in predetermined amounts to water, blood plasma, and whole blood samples, from which a computational analysis was conducted using the Kubelka-Munk calculational method, the Inverse Adding Doubling Method, and the Magic Light Monte Carlo Method to characterized the optical properties such as the absorption (μa) and scattering coefficients (μs) and the scattering anisotropy (g). Through comparison with control samples, the optical properties of each component (blood, plasma, and nanoparticles) can be determined individually, thus illuminating any changes due to the biological environment. The emission from the Nd^3+:Y2O3 particles through the blood is also detected thus exhibiting their usefulness as real world biological markers.

  13. Congruence of Additive and Non-Additive Effects on Gene Expression Estimated from Pedigree and SNP Data

    PubMed Central

    Powell, Joseph E.; Henders, Anjali K.; McRae, Allan F.; Kim, Jinhee; Hemani, Gibran; Martin, Nicholas G.; Dermitzakis, Emmanouil T.; Gibson, Greg

    2013-01-01

    There is increasing evidence that heritable variation in gene expression underlies genetic variation in susceptibility to disease. Therefore, a comprehensive understanding of the similarity between relatives for transcript variation is warranted—in particular, dissection of phenotypic variation into additive and non-additive genetic factors and shared environmental effects. We conducted a gene expression study in blood samples of 862 individuals from 312 nuclear families containing MZ or DZ twin pairs using both pedigree and genotype information. From a pedigree analysis we show that the vast majority of genetic variation across 17,994 probes is additive, although non-additive genetic variation is identified for 960 transcripts. For 180 of the 960 transcripts with non-additive genetic variation, we identify expression quantitative trait loci (eQTL) with dominance effects in a sample of 339 unrelated individuals and replicate 31% of these associations in an independent sample of 139 unrelated individuals. Over-dominance was detected and replicated for a trans association between rs12313805 and ETV6, located 4MB apart on chromosome 12. Surprisingly, only 17 probes exhibit significant levels of common environmental effects, suggesting that environmental and lifestyle factors common to a family do not affect expression variation for most transcripts, at least those measured in blood. Consistent with the genetic architecture of common diseases, gene expression is predominantly additive, but a minority of transcripts display non-additive effects. PMID:23696747

  14. Congruence of additive and non-additive effects on gene expression estimated from pedigree and SNP data.

    PubMed

    Powell, Joseph E; Henders, Anjali K; McRae, Allan F; Kim, Jinhee; Hemani, Gibran; Martin, Nicholas G; Dermitzakis, Emmanouil T; Gibson, Greg; Montgomery, Grant W; Visscher, Peter M

    2013-05-01

    There is increasing evidence that heritable variation in gene expression underlies genetic variation in susceptibility to disease. Therefore, a comprehensive understanding of the similarity between relatives for transcript variation is warranted--in particular, dissection of phenotypic variation into additive and non-additive genetic factors and shared environmental effects. We conducted a gene expression study in blood samples of 862 individuals from 312 nuclear families containing MZ or DZ twin pairs using both pedigree and genotype information. From a pedigree analysis we show that the vast majority of genetic variation across 17,994 probes is additive, although non-additive genetic variation is identified for 960 transcripts. For 180 of the 960 transcripts with non-additive genetic variation, we identify expression quantitative trait loci (eQTL) with dominance effects in a sample of 339 unrelated individuals and replicate 31% of these associations in an independent sample of 139 unrelated individuals. Over-dominance was detected and replicated for a trans association between rs12313805 and ETV6, located 4MB apart on chromosome 12. Surprisingly, only 17 probes exhibit significant levels of common environmental effects, suggesting that environmental and lifestyle factors common to a family do not affect expression variation for most transcripts, at least those measured in blood. Consistent with the genetic architecture of common diseases, gene expression is predominantly additive, but a minority of transcripts display non-additive effects.

  15. Efficacy of Cyto-Chex blood preservative for delayed manual CD4 testing using Dynal T4 Quant CD4 test among HIV-infected persons in Zambia.

    PubMed

    Truett, April A; Letizia, Andrew; Malyangu, Evans; Sinyangwe, Frank; Morales, Brandi N; Crum, Nancy F; Crowe, Suzanne M

    2006-02-01

    Manual CD4 tests such as Dynal T4 Quant (Dynabeads, Dynal Biotech, Oslo, Norway) are less expensive alternatives to flow cytometry in resource-limited countries. Whereas blood preservatives have proven useful for stabilizing blood samples to allow delayed CD4 testing by flow cytometry, they have not been verified for manual tests. A method for preservation of blood prior to manual CD4 testing is needed for long-distance transport or sample batching. Blood from HIV-positive Zambian military beneficiaries was mixed (1:1) with Cyto-Chex (Streck Laboratories, La Vista, NE) blood preservative, and the blood was stored at refrigerated, ambient, and incubator (37 degrees C) temperatures prior to Dynabeads CD4 testing at 0, 3, 6, and 9 days after collection. Baseline flow cytometry and Dynabeads testing without preservative were performed for comparison. Twenty-seven patient samples were analyzed. Dynabeads vs. flow cytometry had a correlation coefficient (r) of 0.84. There was excellent correlation (r = 0.96) between baseline Dynabeads testing and Cyto-Chex-preserved samples. Refrigerated samples showed strong correlation with baseline Dynabeads (r = 0.93-0.95) on days 3, 6, and 9 without decline in CD4 count (P = 0.73). Samples stored at ambient temperature yielded inferior results (r = 0.76-0.81), with a significant decline in CD4 count by day 3 (P < 0.001). The incubator arm had especially poor correlation (r = 0.30-0.49). Addition of Cyto-Chex to peripheral blood (1:1) adequately preserves refrigerated blood samples for up to 9 days for subsequent testing with Dynabeads CD4 test. Cyto-Chex, however, cannot be recommended for delayed Dynabeads CD4 testing with storage at 37 degrees C or ambient temperatures in tropical areas similar to the site of this study.

  16. Assessment of DNA extracted from FTA® cards for use on the Illumina iSelect BeadChip

    PubMed Central

    McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F

    2009-01-01

    Background As FTA® cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes ≥ 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. Findings An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. Conclusion We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform. PMID:19531223

  17. Assessment of DNA extracted from FTA cards for use on the Illumina iSelect BeadChip.

    PubMed

    McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F

    2009-06-16

    As FTA cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes >or= 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform.

  18. Duffy Blood Group Genotyping in Thai Blood Donors

    PubMed Central

    Intharanut, Kamphon; Siriphanthong, Kanokpol; Nathalang, Siriporn; Kupatawintu, Pawinee

    2015-01-01

    Background Duffy (FY) blood group genotyping is important in transfusion medicine because Duffy alloantibodies are associated with delayed hemolytic transfusion reactions and hemolytic disease of the fetus and newborn. In this study, FY allele frequencies in Thai blood donors were determined by in-house PCR with sequence-specific primers (PCR-SSP), and the probability of obtaining compatible blood for alloimmunized patients was assessed. Methods Five hundred blood samples from Thai blood donors of the National Blood Centre, Thai Red Cross Society, were included. Only 200 samples were tested with anti-Fya and anti-Fyb using the gel technique. All 500 samples and four samples from a Guinea family with the Fy(a-b-) phenotype were genotyped by using PCR-SSP. Additionally, the probability of obtaining antigen-negative red blood cells (RBCs) for alloimmunized patients was calculated according to the estimated FY allele frequencies. Results The FY phenotyping and genotyping results were in 100% concordance. The allele frequencies of FY*A and FY*B in 500 central Thais were 0.962 (962/1,000) and 0.038 (38/1,000), respectively. Although the Fy(a-b-) phenotype was not observed in this study, FY*BES/FY*BES was identified by PCR-SSP in the Guinea family and was confirmed by DNA sequencing. Conclusions Our results confirm the high frequency of the FY*A allele in the Thai population, similar to that of Asian populations. At least 500 Thai blood donors are needed to obtain two units of antigen-negative RBCs for the Fy(a-b+) phenotype. PMID:26354350

  19. Rapid Detection of Haptoglobin Gene Deletion in Alkaline-Denatured Blood by Loop-Mediated Isothermal Amplification Reaction

    PubMed Central

    Soejima, Mikiko; Egashira, Kouichi; Kawano, Hiroyuki; Kawaguchi, Atsushi; Sagawa, Kimitaka; Koda, Yoshiro

    2011-01-01

    Anhaptoglobinemic patients run the risk of severe anaphylactic transfusion reaction because they produce serum haptoglobin antibodies. Being homozygous for the haptoglobin gene deletion allele (HPdel) is the only known cause of congenital anhaptoglobinemia, and detection of HPdel before transfusion is important to prevent anaphylactic shock. In this study, we developed a loop-mediated isothermal amplification (LAMP)-based screening for HPdel. Optimal primer sets and temperature for LAMP were selected for HPdel and the 5′ region of the HP using genomic DNA as a template. Then, the effects of diluent and boiling on LAMP amplification were examined using whole blood as a template. Blood samples diluted 1:100 with 50 mmol/L NaOH without boiling gave optimal results as well as those diluted 1:2 with water followed by boiling. The results from 100 blood samples were fully concordant with those obtained by real-time PCR methods. Detection of the HPdel allele by LAMP using alkaline-denatured blood samples is rapid, simple, accurate, and cost effective, and is readily applicable in various clinical settings because this method requires only basic instruments. In addition, the simple preparation of blood samples using NaOH saves time and effort for various genetic tests. PMID:21497293

  20. Molecular identification of trypanosomatids in wild animals.

    PubMed

    Tenório, M S; Oliveira e Sousa, L; Alves-Martin, M F; Paixão, M S; Rodrigues, M V; Starke-Buzetti, W A; Araújo Junior, J P; Lucheis, S B

    2014-06-16

    Diverse wild animal species can be reservoirs of zoonotic flagellate parasites, which can cause pathologic Chagas disease. The present study aimed to detect the natural occurrence of flagellate parasites through direct microscopic examination of the parasites in blood samples and through PCR of whole blood and blood culture (haemoculture) samples from 38 captive and 65 free-living wild animals in the Centre for Conservation of Wild Fauna (CCWF), an area endemic for leishmaniasis. For this study, PCR was accomplished using primers for the ribosomal region (ITS-1) of the flagellate parasites. The amplified fragments were cloned and sequenced to identify DNA of the Trypanosomatid parasite species, observed in blood cultures from 3.9% (04/103) of the animals. Through these techniques, Trypanosoma cruzi was identified in haemoculture samples of the following three free-living species: common agouti (Dasyprocta aguti), white-eared opossum (Didelphis albiventris), and nine-banded armadillo (Dasypus novemcinctus). Furthermore, Trypanosoma minasense was identified in whole blood samples from 01 (0.9%) captive animal (black howler monkey-Alouatta caraya). These results demonstrated the first report of T. cruzi isolation in wild species from the CCWF using blood culture, which can be applied in addition to molecular tools for epidemiological studies and to identify trypanosomatids in wild animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Comparison of gel column, card, and cartridge techniques for dog erythrocyte antigen 1.1 blood typing

    PubMed Central

    Seth, Mayank; Jackson, Karen V.; Winzelberg, Sarah; Giger, Urs

    2012-01-01

    Objective To compare accuracy and ease of use of a card agglutination assay, an immunochromatographic cartridge method, and a gel-based method for canine blood typing. Sample Blood samples from 52 healthy blood donor dogs, 10 dogs with immune-mediated hemolytic anemia (IMHA), and 29 dogs with other diseases. Procedures Blood samples were tested in accordance with manufacturer guidelines. Samples with low PCVs were created by the addition of autologous plasma to separately assess the effects of anemia on test results. Results Compared with a composite reference standard of agreement between 2 methods, the gel-based method was found to be 100% accurate. The card agglutination assay was 89% to 91% accurate, depending on test interpretation, and the immunochromatographic cartridge method was 93% accurate but 100% specific. Errors were observed more frequently in samples from diseased dogs, particularly those with IMHA. In the presence of persistent autoagglutination, dog erythrocyte antigen (DEA) 1.1 typing was not possible, except with the immunochromatographic cartridge method. Conclusions and Clinical Relevance The card agglutination assay and immunochromatographic cartridge method, performed by trained personnel, were suitable for in-clinic emergency DEA 1.1 blood typing. There may be errors, particularly for samples from dogs with IMHA, and the immunochromatographic cartridge method may have an advantage of allowing typing of samples with persistent autoagglutination. The laboratory gel-based method would be preferred for routine DEA 1.1 typing of donors and patients if it is available and time permits. Current DEA 1.1 typing techniques appear to be appropriately standardized and easy to use. PMID:22280380

  2. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    PubMed

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Evaluation of pyramid training as a method to increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

    PubMed

    Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke

    2017-06-15

    OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.

  4. Environmental exposures to lead, mercury, and cadmium among South Korean teenagers (KNHANES 2010-2013): Body burden and risk factors.

    PubMed

    Kim, Nam-Soo; Ahn, Jaeouk; Lee, Byung-Kook; Park, Jungsun; Kim, Yangho

    2017-07-01

    Limited information is available on the association of age and sex with blood concentrations of heavy metals in teenagers. In addition, factors such as a shared family environment may have an association. We analyzed data from the Korean National Health and Nutrition Examination Survey (KNHANES, 2010-2013) to determine whether blood levels of heavy metals differ by risk factors such as age, sex, and shared family environment in a representative sample of teenagers. This study used data obtained in the KNHANES 2010-2013, which had a rolling sampling design that involved a complex, stratified, multistage, probability-cluster survey of a representative sample of the non-institutionalized civilian population in South Korea. Our cross-sectional analysis was restricted to teenagers and their parents who completed the health examination survey, and for whom blood measurements of cadmium, lead, and mercury were available. The final analytical sample consisted of 1585 teenagers, and 376 fathers and 399 mothers who provided measurements of blood heavy metal concentrations. Male teenagers had greater blood levels of lead and mercury, but sex had no association with blood cadmium level. There were age-related increases in blood cadmium, but blood lead decreased with age, and age had little association with blood mercury. The concentrations of cadmium and mercury declined from 2010 to 2013. The blood concentrations of lead, cadmium, and mercury in teenagers were positively associated with the levels in their parents after adjustment for covariates. Our results show that blood heavy metal concentrations differ by risk factors such as age, sex, and shared family environment in teenagers. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. 25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays

    PubMed Central

    Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li’an; Xia, Liangyu; Qiu, Ling

    2015-01-01

    Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy. PMID:26420221

  6. 25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays.

    PubMed

    Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li'an; Xia, Liangyu; Qiu, Ling

    2015-09-30

    Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy.

  7. Colour coding for blood collection tube closures - a call for harmonisation.

    PubMed

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  8. Frequency and Clinical Epidemiology of Canine Monocytic Ehrlichiosis in Dogs Infested with Ticks from Sinaloa, Mexico

    PubMed Central

    Sosa-Gutierrez, Carolina Guadalupe; Quintero Martinez, Maria Teresa; Gaxiola Camacho, Soila Maribel; Esteve-Gassent, Maria D.; Gordillo-Pérez, María-Guadalupe

    2013-01-01

    Ehrlichia canis is a rickettsial intracellular obligate bacterial pathogen and agent of canine monocytic ehrlichiosis. The prevalence of this disease in veterinary medicine can vary depending on the diagnostic method used and the geographic location. One hundred and fifty-two canine blood samples from six veterinary clinics and two shelters from Sinaloa State (Mexico) were analyzed in this study. All animals were suspected of having Canine Monocytic Ehrlichiosis (CME). The diagnostic methods used were the ELISA (Snap4Dx, IDEXX) together with blood smear and platelet count. From all dogs blood samples analyzed, 74.3% were positive to E. canis by ELISA and 40.1% were positive by blood smear. The sensitivity and specificity observed in the ELISA test were 78.8% and 86.7%. In addition, thrombocytopenia was presented in 87.6% of positive dogs. The predominant clinical manifestations observed were fever, anorexia, depression, lethargy, and petechiae. Consequently, this is the first report in which the morulae were visualized in the blood samples, and E. canis-specific antibodies were detected in dogs from Sinaloa, Northwest of Mexico. PMID:26464910

  9. IN VIVO KINETICS OF PHENYLGLUCURONIDE, A PHASE II CONJUGATE OF PHENOLE, IN BLOOD AND URINE OF RAINBOW TROUT

    EPA Science Inventory

    The kinetics of phenylglucuronide (PG) in blood and urine of spinally-transected rainbow trout were investigated using microdialysis sampling techniques. Trout weighing 0.9 to 1.3 kg were dosed continuously with PG for an additional 48 h. PG could not be detected in expired branc...

  10. Trace of heavy metals in maternal and umbilical cord blood samples in association with birth outcomes in Baghdad, Iraq

    NASA Astrophysics Data System (ADS)

    Hasan Rhaif Al-Sahlanee, Mayyadah; Maizan Ramli, Ramzun; Abdul Hassan Ali, Miami; Fadhil Tawfiq, Nada; Zahirah Noor Azman, Nurul; Abdul Rahman, Azhar; Shahrim Mustafa, Iskandar; Noor Ashikin Nik Abdul Razak, Nik; Zakiah Yahaya, Nor; Mohammed Al-Marri, Hana; Syuhada Ayob, Nur; Zakaria, Nabela

    2017-10-01

    Trace elements are essential nutritional components in humans and inconvenient tissue content that have a significant influence on infant size. The aim of this study is to evaluate the effects of concentration of elements (uranium (U), lead (Pb) and iron (Fe)) and absorption of Pb and Fe on maternal and umbilical cord blood samples. The concentration and absorption of Pb and Fe in blood samples were determined by using atomic absorption spectrophotometry device, while the uranium concentration was determined by using CR-39 detector. Fifty women of age 16-44 years are involved in this study. Results show that the maximum and minimum values of both concentration and absorption in the maternal samples were for Pb and Fe, respectively. In addition, for umbilical cord, the maximum values of concentration and absorption were for Fe and the minimum concentration and absorption were for U and Pb, respectively. A significant correlation between maternal and umbilical cord blood samples was found. This indicates that the Pb, U and Fe elements can easily transfer from maternal to the fetal body which impacts the growth of fetus.

  11. The detection of melanoma cells in peripheral blood by reverse transcription-polymerase chain reaction.

    PubMed Central

    Foss, A. J.; Guille, M. J.; Occleston, N. L.; Hykin, P. G.; Hungerford, J. L.; Lightman, S.

    1995-01-01

    Both cutaneous and uveal melanoma undergo haematogenous dissemination. Detection of tyrosinase mRNA by reverse transcription-polymerase chain reaction (RT-PCR) has been described as an extremely sensitive way of detecting circulating viable melanoma cells in the peripheral venous blood, and this technique may be of value in the early detection of dissemination. Also, it has been suggested that surgical manipulation of the eye, such as occurs during enucleation, can provoke uveal melanoma dissemination. The purpose of this study was to evaluate whether tyrosinase mRNA is detectable in the peripheral blood of patients with uveal and cutaneous melanoma and in patients with uveal melanoma undergoing surgical procedures on the eye harbouring the tumour. Venous blood samples from 36 patients diagnosed as having active uveal melanoma and from six patients with advanced metastatic cutaneous melanoma were analysed. In addition, blood samples were spiked with known numbers of cells from three cell lines and four primary uveal melanoma cultures. The reported sensitivity of the technique was confirmed, with an ability to detect down to one cell per ml of blood. All 51 blood samples from the 36 patients with uveal melanoma were negative, and this included 20 perioperative blood samples. The test was also negative for the six patients with advanced cutaneous melanoma. There were two positives among 31 control samples analysed. This study demonstrates that there are far fewer circulating viable melanocytes than has been previously supposed in patients with melanoma and that the RT-PCR is of no clinical value in detecting metastatic melanoma disease. There was no evidence for surgery causing a bolus of melanoma cells to enter the peripheral circulation. Images Figure 1 Figure 2 PMID:7599046

  12. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry

    PubMed Central

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Background: Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. Objective: The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Methods: Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. Results: The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Conclusions: Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group. PMID:27858671

  13. Routine screening of blood donations at Qingdao central blood bank, China, for hepatitis B virus (HBV) DNA with a real-time, multiplex nucleic acid test for HBV, hepatitis C virus, and human immunodeficiency virus Types 1 and 2.

    PubMed

    Yang, Zhongsi; Xu, Lei; Liu, Li; Feng, Qiuxia; Zhang, Longmu; Ma, Weijuan; Saldanha, John; Wang, Mingmin; Zhao, Lin

    2013-10-01

    The Roche cobas TaqScreen MPX test was used to evaluate the rate of hepatitis B surface antigen (HBsAg)-negative donations that were hepatitis B virus (HBV) DNA reactive from June 2010 to January 2011 in Qingdao, China. HBsAg-negative samples from 65,800 voluntary blood donors were tested with the cobas TaqScreen MPX test in pools of 6 on the Roche cobas s 201 blood screening platform. Samples positive for HBV DNA and negative for HBsAg were quantitated with the Roche COBAS AmpliPrep/COBAS TaqMan HBV test. In addition, serologic tests for HBsAg, hepatitis B surface antibody, anti-hepatitis B core antigen (anti-HBc), anti-hepatitis B e antigen (anti-HBe), and hepatitis B e antigen (HBe) were done using the Roche electrochemiluminescence immunoassay. A total of 80 nucleic acid amplification technology (NAT) test-reactive pools were identified and 59 pools (74%) resolved to a reactive sample. All samples were HBV DNA reactive and the viral load in each sample was quantitated. The viral loads of the samples ranged from less than 20 to 34,600 IU/mL; 13 samples (22%) had viral loads of more than 20 IU/mL, 27 samples (45.8%) had viral loads of less than 20 IU/mL, and 19 samples (32.2%) had undetectable viral loads. Of the 59 NAT-reactive samples, 40 (67.8%) were anti-HBc positive. Fifteen of the 59 samples could not be confirmed as NAT reactive either by an alternative NAT test or by serology. The HBV NAT yield in blood donors in Qingdao is 0.06% (38/65,800). This study confirmed the value of NAT for interdicting HBV-positive donations and preventing transfusion-transmitted HBV infections. © 2013 American Association of Blood Banks.

  14. Acoustic radiation force induced resonance elastography of coagulating blood: theoretical viscoelasticity modeling and ex vivo experimentation

    NASA Astrophysics Data System (ADS)

    Bhatt, Manish; Montagnon, Emmanuel; Destrempes, François; Chayer, Boris; Kazemirad, Siavash; Cloutier, Guy

    2018-03-01

    Deep vein thrombosis is a common vascular disease that can lead to pulmonary embolism and death. The early diagnosis and clot age staging are important parameters for reliable therapy planning. This article presents an acoustic radiation force induced resonance elastography method for the viscoelastic characterization of clotting blood. The physical concept of this method relies on the mechanical resonance of the blood clot occurring at specific frequencies. Resonances are induced by focusing ultrasound beams inside the sample under investigation. Coupled to an analytical model of wave scattering, the ability of the proposed method to characterize the viscoelasticity of a mimicked venous thrombosis in the acute phase is demonstrated. Experiments with a gelatin-agar inclusion sample of known viscoelasticity are performed for validation and establishment of the proof of concept. In addition, an inversion method is applied in vitro for the kinetic monitoring of the blood coagulation process of six human blood samples obtained from two volunteers. The computed elasticity and viscosity values of blood samples at the end of the 90 min kinetics were estimated at 411  ±  71 Pa and 0.25  ±  0.03 Pa · s for volunteer #1, and 387  ±  35 Pa and 0.23  ±  0.02 Pa · s for volunteer #2, respectively. The proposed method allowed reproducible time-varying thrombus viscoelastic measurements from samples having physiological dimensions.

  15. Identifying the potential of changes to blood sample logistics using simulation.

    PubMed

    Jørgensen, Pelle; Jacobsen, Peter; Poulsen, Jørgen Hjelm

    2013-01-01

    Using simulation as an approach to display and improve internal logistics at hospitals has great potential. This study shows how a simulation model displaying the morning blood-taking round at a Danish public hospital can be developed and utilized with the aim of improving the logistics. The focus of the simulation was to evaluate changes made to the transportation of blood samples between wards and the laboratory. The average- (AWT) and maximum waiting time (MWT) from a blood sample was drawn at the ward until it was received at the laboratory, and the distribution of arrivals of blood samples in the laboratory were used as the evaluation criteria. Four different scenarios were tested and compared with the current approach: (1) Using AGVs (mobile robots), (2) using a pneumatic tube system, (3) using porters that are called upon, or (4) using porters that come to the wards every 45 minutes. Furthermore, each of the scenarios was tested in terms of what amount of resources would give the optimal result. The simulations showed a big improvement potential in implementing a new technology/mean for transporting the blood samples. The pneumatic tube system showed the biggest potential lowering the AWT and MWT with approx. 36% and 18%, respectively. Additionally, all of the scenarios had a more even distribution of arrivals except for porters coming to the wards every 45 min. As a consequence of the results obtained in the study, the hospital decided to implement a pneumatic tube system.

  16. Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma

    PubMed Central

    Sonnenberg, Avery; Marciniak, Jennifer Y.; Skowronski, Elaine A.; Manouchehri, Sareh; Rassenti, Laura; Ghia, Emanuela M.; Widhopf, George F.; Kipps, Thomas J.; Heller, Michael J.

    2014-01-01

    Conventional methods for the isolation of cancer-related circulating cell-free (ccf) DNA from patient blood (plasma) are time consuming and laborious. A DEP approach utilizing a microarray device now allows rapid isolation of ccf-DNA directly from a small volume of unprocessed blood. In this study, the DEP device is used to compare the ccf-DNA isolated directly from whole blood and plasma from 11 chronic lymphocytic leukemia (CLL) patients and one normal individual. Ccf-DNA from both blood and plasma samples was separated into DEP high-field regions, after which cells (blood), proteins, and other biomolecules were removed by a fluidic wash. The concentrated ccf-DNA was detected on-chip by fluorescence, and then eluted for PCR and DNA sequencing. The complete process from blood to PCR required less than 10 min; an additional 15 min was required to obtain plasma from whole blood. Ccf-DNA from the equivalent of 5 µL of CLL blood and 5 µL of plasma was amplified by PCR using Ig heavy-chain variable (IGHV) specific primers to identify the unique IGHV gene expressed by the leukemic B-cell clone. The PCR and DNA sequencing results obtained by DEP from all 11 CLL blood samples and from 8 of the 11 CLL plasma samples were exactly comparable to the DNA sequencing results obtained from genomic DNA isolated from CLL patient leukemic B cells (gold standard). PMID:24723219

  17. Dielectrophoretic isolation and detection of cancer-related circulating cell-free DNA biomarkers from blood and plasma.

    PubMed

    Sonnenberg, Avery; Marciniak, Jennifer Y; Skowronski, Elaine A; Manouchehri, Sareh; Rassenti, Laura; Ghia, Emanuela M; Widhopf, George F; Kipps, Thomas J; Heller, Michael J

    2014-07-01

    Conventional methods for the isolation of cancer-related circulating cell-free (ccf) DNA from patient blood (plasma) are time consuming and laborious. A DEP approach utilizing a microarray device now allows rapid isolation of ccf-DNA directly from a small volume of unprocessed blood. In this study, the DEP device is used to compare the ccf-DNA isolated directly from whole blood and plasma from 11 chronic lymphocytic leukemia (CLL) patients and one normal individual. Ccf-DNA from both blood and plasma samples was separated into DEP high-field regions, after which cells (blood), proteins, and other biomolecules were removed by a fluidic wash. The concentrated ccf-DNA was detected on-chip by fluorescence, and then eluted for PCR and DNA sequencing. The complete process from blood to PCR required less than 10 min; an additional 15 min was required to obtain plasma from whole blood. Ccf-DNA from the equivalent of 5 μL of CLL blood and 5 μL of plasma was amplified by PCR using Ig heavy-chain variable (IGHV) specific primers to identify the unique IGHV gene expressed by the leukemic B-cell clone. The PCR and DNA sequencing results obtained by DEP from all 11 CLL blood samples and from 8 of the 11 CLL plasma samples were exactly comparable to the DNA sequencing results obtained from genomic DNA isolated from CLL patient leukemic B cells (gold standard). © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A microfluidic approach for hemoglobin detection in whole blood

    NASA Astrophysics Data System (ADS)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  19. The effects of hurricane Rita and subsequent drought on alligators in southwest Louisiana.

    PubMed

    Lance, Valentine A; Elsey, Ruth M; Butterstein, George; Trosclair, Phillip L; Merchant, Mark

    2010-02-01

    Hurricane Rita struck the coast of southwest Louisiana in September 2005. The storm generated an enormous tidal surge of approximately four meters in height that inundated many thousands of acres of the coastal marsh with full strength seawater. The initial surge resulted in the deaths of a number of alligators and severely stressed those who survived. In addition, a prolonged drought (the lowest rainfall in 111 years of recorded weather data) following the hurricane resulted in highly saline conditions that persisted in the marsh for several months. We had the opportunity to collect 11 blood samples from alligators located on Holly Beach less than a month after the hurricane, but were unable to collect samples from alligators on Rockefeller Wildlife Refuge until February 2006. Conditions at Rockefeller Refuge did not permit systematic sampling, but a total of 201 samples were collected on the refuge up through August 2006. The blood samples were analyzed for sodium, potassium, chloride, osmolality, and corticosterone. Blood samples from alligators sampled on Holly Beach in October 2005, showed a marked elevation in plasma osmolality, sodium, chloride, potassium, corticosterone, and an elevated heterophil/lymphocyte ratio. Blood samples from alligators on Rockefeller Refuge showed increasing levels of corticosterone as the drought persisted and elevated osmolality and electrolytes. After substantial rainfall in July and August, these indices of osmotic stress returned to within normal limits. (c) 2009 Wiley-Liss, Inc.

  20. The Blood Donation Ambivalence Survey: measuring conflicting attitudes about giving blood.

    PubMed

    Fox, K R; Himawan, L K; France, C R

    2017-05-18

    This study was designed to develop and conduct initial validation testing for a novel measure of ambivalence about donating blood. Previous studies of living organ, bone marrow and stem cell donors have identified donation-related ambivalence as a predictor of decisions about donation and post-donation outcomes. Ambivalence about blood donation has not received the same attention. In Study 1, a sample of young adults (N = 396) were administered test items of ambivalence, and exploratory (EFA) and confirmatory factor analyses (CFA) were performed to identify the Blood Donation Ambivalence Survey. In Study 2, a separate sample of young adults (N = 241) completed the Blood Donation Ambivalence Survey in addition to questionnaires assessing known predictors of blood donation. Exploratory and confirmatory factor analyses indicated a two-factor structure reflecting commitment to donating blood and indecision about giving blood. The commitment subscale was positively related to known predictors of increased donation behaviour (e.g. donation intention, self-efficacy), whereas the indecision subscale was positively related to known predictors of decreased donation behaviour (e.g. donation anxiety, negative affect). Furthermore, a history of blood donation was associated with greater commitment and less indecision. The present findings provide strong initial support for the reliability and validity of a novel measure of blood donor ambivalence. © 2017 British Blood Transfusion Society.

  1. A LC-MS/MS method to monitor the concentration of HYD-PEP06, a RGD-modified Endostar mimetic peptide in rat blood.

    PubMed

    Dong, Xiaona; Zhang, Yiwei; Meng, Zhiyun; Zhu, Xiaoxia; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Li, Jian; Zheng, Ying; Yang, Baofeng; Dou, Guifang

    2018-05-29

    HYD-PEP06 is a novel RGD-modified Endostar mimetic peptide with 30 amino acids that is intended to suppress the formation of neoplasm vessels. This assay was developed and validated to monitor the level of the peptide HYD-PEP06 in rat blood, using liquid chromatography tandem mass spectrometry (LC-MS/MS). HYD-PEP10, another peptide similar to the analyte, was used as an internal standard (IS). A triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode and an electrospray interface (ESI) in the positive mode were used for MS analysis. The analysis was optimized with addition of 0.3% formic acid (FA) into the mobile phase as well as with a needle washing solution to overcome the carryover effect. In addition, the carryover was reduced by optimizing the mobile phase gradient. Methanol was used as a diluent of working solutions to avoid any adsorption. Methanol:acetonitrile (1:1, v:v) containing 0.3% FA was employed to precipitate the blood samples. Unknown blood samples must be placed in ice bath immediately, and precipitating agents should be added within 30 min to ensure the stability of blood samples. The assay was established and validated. This method showed a good linear relationship for the HYD-PEP06 in the range of 10 ng·mL -1 to 2000 ng·mL -1 , with R > 0.99. HYD-PEP06 was determined with accuracy values (RE%) of -5.06%-8.54%, intra- and inter-day precisions (RSD%) of 3.13%-4.87% and 4.81%-9.42%. The method was successfully in monitoring the concentration of HYD-PEP06 in rat blood. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Effect of solvent/detergent-treated pooled plasma on fibrinolysis in reconstituted whole blood.

    PubMed

    Saadah, Nicholas H; van der Meer, Pieter F; Brinkman, Herm Jan M; de Korte, Dirk; Bontekoe, Ido J; Korsten, Herbert H; Middelburg, Rutger A; van der Bom, Johanna G; Schipperus, Martin R

    2017-10-01

    Hyperfibrinolysis has been observed in patients heavily transfused with solvent/detergent-treated pooled plasma (S/D plasma). We compared coagulation and fibrinolytic variables in blood containing S/D plasma with blood containing fresh-frozen plasma (FFP), with and without α2-antiplasmin or tranexamic acid (TXA) supplementation. Whole blood samples were reconstituted from red blood cells, platelet (PLT) concentrates, and varying mixtures of FFP and S/D plasma. Hematocrit and PLT count of reconstituted whole blood samples were varied. For a subset of runs, α2-antiplasmin or TXA was added to S/D plasma whole blood samples. Thromboelastography (TEG) analysis was performed to assess 50% clot lysis time (CLT 50% ), maximum amplitude (MA), and initial clotting time (R-time). The change in CLT 50% of whole blood as the plasma compartment transitions from FFP to S/D plasma was -52% (95% confidence interval [CI], -60% to -45%; p < 0.001). PLT count strengthened the effect, leading to an additional change in CLT 50% of -8% (95% CI, -14% to -2%; p = 0.012) as PLT count increased from 10 × 10 9 to 150 × 10 9 /L. MA and R-time were not associated with fraction of S/D plasma in whole blood. α2-Antiplasmin and TXA restored clot lysis time in S/D plasma whole blood. Whole blood with S/D plasma has shorter clot lysis times in vitro compared to whole blood with FFP. α2-Antiplasmin and TXA restore clot lysis time of S/D plasma whole blood to that of FFP whole blood. Clinicians should be aware of the decreased clot lysis time associated with S/D plasma transfusion. © 2017 AABB.

  3. Semi-automated in vivo solid-phase microextraction sampling and the diffusion-based interface calibration model to determine the pharmacokinetics of methoxyfenoterol and fenoterol in rats.

    PubMed

    Yeung, Joanne Chung Yan; de Lannoy, Inés; Gien, Brad; Vuckovic, Dajana; Yang, Yingbo; Bojko, Barbara; Pawliszyn, Janusz

    2012-09-12

    In vivo solid-phase microextraction (SPME) can be used to sample the circulating blood of animals without the need to withdraw a representative blood sample. In this study, in vivo SPME in combination with liquid-chromatography tandem mass spectrometry (LC-MS/MS) was used to determine the pharmacokinetics of two drug analytes, R,R-fenoterol and R,R-methoxyfenoterol, administered as 5 mg kg(-1) i.v. bolus doses to groups of 5 rats. This research illustrates, for the first time, the feasibility of the diffusion-based calibration interface model for in vivo SPME studies. To provide a constant sampling rate as required for the diffusion-based interface model, partial automation of the SPME sampling of the analytes from the circulating blood was accomplished using an automated blood sampling system. The use of the blood sampling system allowed automation of all SPME sampling steps in vivo, except for the insertion and removal of the SPME probe from the sampling interface. The results from in vivo SPME were compared to the conventional method based on blood withdrawal and sample clean up by plasma protein precipitation. Both whole blood and plasma concentrations were determined by the conventional method. The concentrations of methoxyfenoterol and fenoterol obtained by SPME generally concur with the whole blood concentrations determined by the conventional method indicating the utility of the proposed method. The proposed diffusion-based interface model has several advantages over other kinetic calibration models for in vivo SPME sampling including (i) it does not require the addition of a standard into the sample matrix during in vivo studies, (ii) it is simple and rapid and eliminates the need to pre-load appropriate standard onto the SPME extraction phase and (iii) the calibration constant for SPME can be calculated based on the diffusion coefficient, extraction time, fiber length and radius, and size of the boundary layer. In the current study, the experimental calibration constants of 338.9±30 mm(-3) and 298.5±25 mm(-3) are in excellent agreement with the theoretical calibration constants of 307.9 mm(-3) and 316.0 mm(-3) for fenoterol and methoxyfenoterol respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Enlarged leukocyte referent libraries can explain additional variance in blood-based epigenome-wide association studies.

    PubMed

    Kim, Stephanie; Eliot, Melissa; Koestler, Devin C; Houseman, Eugene A; Wetmur, James G; Wiencke, John K; Kelsey, Karl T

    2016-09-01

    We examined whether variation in blood-based epigenome-wide association studies could be more completely explained by augmenting existing reference DNA methylation libraries. We compared existing and enhanced libraries in predicting variability in three publicly available 450K methylation datasets that collected whole-blood samples. Models were fit separately to each CpG site and used to estimate the additional variability when adjustments for cell composition were made with each library. Calculation of the mean difference in the CpG-specific residual sums of squares error between models for an arthritis, aging and metabolic syndrome dataset, indicated that an enhanced library explained significantly more variation across all three datasets (p < 10(-3)). Pathologically important immune cell subtypes can explain important variability in epigenome-wide association studies done in blood.

  5. Extensive monitoring through multiple blood samples in professional soccer players.

    PubMed

    Heisterberg, Mette F; Fahrenkrug, Jan; Krustrup, Peter; Storskov, Anders; Kjær, Michael; Andersen, Jesper L

    2013-05-01

    The aim of this study was to make a comprehensive gathering of consecutive detailed blood samples from professional soccer players and to analyze different blood parameters in relation to seasonal changes in training and match exposure. Blood samples were collected 5 times during a 6-month period and analyzed for 37 variables in 27 professional soccer players from the best Danish league. Additionally, the players were tested for body composition, V[Combining Dot Above]O2max and physical performance by the Yo-Yo intermittent endurance submax test (IE2). Multiple variations in blood parameters occurred during the observation period, including a decrease in hemoglobin and an increase in hematocrit as the competitive season progressed. Iron and transferrin were stable, whereas ferritin showed a decrease at the end of the season. The immunoglobulin A (IgA) and IgM increased in the period with basal physical training and at the end of the season. Leucocytes decreased with increased physical training. Lymphocytes decreased at the end of the season. The V[Combining Dot Above]O2max decreased toward the end of the season, whereas no significant changes were observed in the IE2 test. The regular blood samples from elite soccer players reveal significant changes that may be related to changes in training pattern, match exposure, or length of the match season. Especially the end of the preparation season and at the end of the competitive season seem to be time points were the blood-derived values indicate that the players are under excessive physical strain and might be more subjected to a possible overreaching-overtraining conditions. We suggest that regular analyses of blood samples could be an important initiative to optimize training adaptation, training load, and game participation, but sampling has to be regular, and a database has to be built for each individual player.

  6. Quantitative photoacoustic characterization of blood clot in blood: A mechanobiological assessment through spectral information

    NASA Astrophysics Data System (ADS)

    Biswas, Deblina; Vasudevan, Srivathsan; Chen, George C. K.; Sharma, Norman

    2017-02-01

    Formation of blood clots, called thrombus, can happen due to hyper-coagulation of blood. Thrombi, while moving through blood vessels can impede blood flow, an important criterion for many critical diseases like deep vein thrombosis and heart attacks. Understanding mechanical properties of clot formation is vital for assessment of severity of thrombosis and proper treatment. However, biomechanics of thrombus is less known to clinicians and not very well investigated. Photoacoustic (PA) spectral response, a non-invasive technique, is proposed to investigate the mechanism of formation of blood clots through elasticity and also differentiate clots from blood. Distinct shift (increase in frequency) of the PA response dominant frequency during clot formation is reported. In addition, quantitative differentiation of blood clots from blood has been achieved through parameters like dominant frequency and spectral energy of PA spectral response. Nearly twofold increases in dominant frequency in blood clots compared to blood were found in the PA spectral response. Significant changes in energy also help in quantitatively differentiating clots from blood, in the blood. Our results reveal that increase in density during clot formation is reflected in the PA spectral response, a significant step towards understanding the mechanobiology of thrombus formation. Hence, the proposed tool, in addition to detecting thrombus formation, could reveal mechanical properties of the sample through quantitative photoacoustic spectral parameters.

  7. Increased frequency of sister chromatid exchanges and decrease in cell viability and proliferation kinetics in human peripheral blood lymphocytes after in vitro exposure to whole bee venom.

    PubMed

    Gajski, Goran; Garaj-Vrhovac, Vera

    2010-10-01

    The present study was aimed to investigate the impact of bee venom on frequency of sister chromatid exchanges (SCE) and viability in human peripheral blood lymphocytes in vitro. In addition, the proportion of lymphocytes that undergo one, two or three cell divisions as well as proliferative rate index (PRI) have been determined. Aqueous solution of whole bee venom was added to whole blood samples in concentrations ranging from 0.1 microg/mL to 20 microg/mL in different lengths of time. Results showed that whole bee venom inhibited cell viability, resulting in a 22.86 +/- 1.14% and 51.21 +/- 0.58% reduction of viable cells at 1 hour and 6 hours, respectively. The mean SCE per cell in all the exposed samples was significantly higher than in the corresponding controls. In addition, the percentage of high frequency cells (HFC) for each sample was estimated using the pooled distribution of all SCE measurements. This parameter was also significantly higher compared to the control. Inhibition of proliferation was statistically significant for both exposure times and concentrations and was time and dose dependent. These data indicate that whole bee venom inhibited cell proliferation, resulting in a 36.87 +/- 5.89% and 38.43 +/- 1.96% reduction of proliferation at 1 hour and 6 hours, respectively. In conclusion, this report demonstrated that whole bee venom is capable of inducing DNA alterations by virtue of increasing sister chromatid exchanges in addition to the cell viability decrease and inhibition of proliferation kinetics in human peripheral blood lymphocytes in vitro.

  8. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

    PubMed

    Arslan, Fatma Demet; Karakoyun, Inanc; Basok, Banu Isbilen; Aksit, Merve Zeytinli; Baysoy, Anil; Ozturk, Yasemin Kilic; Guclu, Yusuf Adnan; Duman, Can

    2017-10-15

    Although serum-providing blood tubes with a barrier are still widely used due to their significant advantages, the use of blood tubes with a barrier to provide plasma is becoming widespread. We compared 22 analytes in a BD Vacutainer® Barricor LH Plasma tube for local clinical validation of this new lithium heparin tube with a barrier. Samples from 44 volunteers were collected in different tubes (Becton Dickinson and Company): Z tube without additive (reference), clot-activator tube with gel (SST), lithium heparin tube without gel (LiH), and lithium heparin tube with barrier (Barricor). Analyte concentrations in different tubes were compared with the reference tube. All tubes were also evaluated according to additional testing (different centrifugation durations, blood-sampling techniques and individual differences). Aspartate aminotransferase (AST), glucose (Glc), potassium (K), lactate dehydrogenase (LD), sodium (Na), and total protein (TP) had a significant bias in Barricor (9.19%, - 3.24%, - 4.88%, 21.60%, - 0.40%, 5.03%, respectively) relative to the reference tube. There was no statistical difference between different centrifugation durations and individual differences for AST, K and LD in LiH and/or Barricor (P > 0.05). There was a significant bias for LD between LiH and Barricor in terms of blood-sampling techniques (21.2% and 12.4%, respectively). Recently, the use of plasma has become prominent due to some of its advantages. In this study, plasma AST, K, LD, Glc and TP levels in Barricor were clinically different in comparison to serum. The results of additional tests showed that higher levels of LD in Barricor did not result from haemolysis, and they might be related to other factors including number of platelets, cellular fragility, or functional environment.

  9. Effect of blood sampling schedule and method of calculating the area under the curve on validity and precision of glycaemic index values.

    PubMed

    Wolever, Thomas M S

    2004-02-01

    To evaluate the suitability for glycaemic index (GI) calculations of using blood sampling schedules and methods of calculating area under the curve (AUC) different from those recommended, the GI values of five foods were determined by recommended methods (capillary blood glucose measured seven times over 2.0 h) in forty-seven normal subjects and different calculations performed on the same data set. The AUC was calculated in four ways: incremental AUC (iAUC; recommended method), iAUC above the minimum blood glucose value (AUCmin), net AUC (netAUC) and iAUC including area only before the glycaemic response curve cuts the baseline (AUCcut). In addition, iAUC was calculated using four different sets of less than seven blood samples. GI values were derived using each AUC calculation. The mean GI values of the foods varied significantly according to the method of calculating GI. The standard deviation of GI values calculating using iAUC (20.4), was lower than six of the seven other methods, and significantly less (P<0.05) than that using netAUC (24.0). To be a valid index of food glycaemic response independent of subject characteristics, GI values in subjects should not be related to their AUC after oral glucose. However, calculating GI using AUCmin or less than seven blood samples resulted in significant (P<0.05) relationships between GI and mean AUC. It is concluded that, in subjects without diabetes, the recommended blood sampling schedule and method of AUC calculation yields more valid and/or more precise GI values than the seven other methods tested here. The only method whose results agreed reasonably well with the recommended method (ie. within +/-5 %) was AUCcut.

  10. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    PubMed

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Further evaluation of the NWF filter for the purification of Plasmodium vivax-infected erythrocytes.

    PubMed

    Li, Jiangyan; Tao, Zhiyong; Li, Qian; Brashear, Awtum; Wang, Ying; Xia, Hui; Fang, Qiang; Cui, Liwang

    2017-05-17

    Isolation of Plasmodium-infected red blood cells (iRBCs) from clinical blood samples is often required for experiments, such as ex vivo drug assays, in vitro invasion assays and genome sequencing. Current methods for removing white blood cells (WBCs) from malaria-infected blood are time-consuming or costly. A prototype non-woven fabric (NWF) filter was developed for the purification of iRBCs, which showed great efficiency for removing WBCs in a pilot study. Previous work was performed with prototype filters optimized for processing 5-10 mL of blood. With the commercialization of the filters, this study aims to evaluate the efficiency and suitability of the commercial NWF filter for the purification of Plasmodium vivax-infected RBCs in smaller volumes of blood and to compare its performance with that of Plasmodipur ® filters. Forty-three clinical P. vivax blood samples taken from symptomatic patients attending malaria clinics at the China-Myanmar border were processed using the NWF filters in a nearby field laboratory. The numbers of WBCs and iRBCs and morphology of P. vivax parasites in the blood samples before and after NWF filtration were compared. The viability of P. vivax parasites after filtration from 27 blood samples was examined by in vitro short-term culture. In addition, the effectiveness of the NWF filter for removing WBCs was compared with that of the Plasmodipur ® filter in six P. vivax blood samples. Filtration of 1-2 mL of P. vivax-infected blood with the NWF filter removed 99.68% WBCs. The densities of total iRBCs, ring and trophozoite stages before and after filtration were not significantly different (P > 0.05). However, the recovery rates of schizont- and gametocyte-infected RBCs, which were minor parasite stages in the clinical samples, were relatively low. After filtration, the P. vivax parasites did not show apparent morphological changes. Culture of 27 P. vivax-infected blood samples after filtration showed that parasites successfully matured into the schizont stage. The WBC removal rates and iRBC recovery rates were not significantly different between the NWF and Plasmodipur ® filters (P > 0.05). When tested with 1-2 mL of P. vivax-infected blood, the NWF filter could effectively remove WBCs and the recovery rates for ring- and trophozoite-iRBCs were high. P. vivax parasites after filtration could be successfully cultured in vitro to reach maturity. The performance of the NWF and Plasmodipur ® filters for removing WBCs and recovering iRBCs was comparable.

  12. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  13. Practical and quality-control aspects of multi-element analysis with quadrupole ICP-MS with special attention to urine and whole blood.

    PubMed

    De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert

    2004-07-01

    Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.

  14. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response.

    PubMed

    Mulloy, Deborah F; Lee, Susan M; Gregas, Matthew; Hoffman, Kate E; Ashley, Stanley W

    2018-04-01

    To evaluate the effect of daily PIV-based phlebotomy using the PIVO device on PIVC dwell times and replacement rates, as well as the reliability of blood sample collection, and patient response to this method of blood collection. Blood draws which are also known as phlebotomy for laboratory analyses are one of the most common experiences for hospitalized patients. When performed by venipuncture, they are often associated with pain and anxiety for patients. Most hospitals avoid phlebotomy from peripheral IV catheters due to sample hemolysis, sample dilution by fluids in PIVC line or infused medications, PIVC dislodgement or infiltration, and increased rates of phlebitis. A prospective, randomized- controlled study of 160 GI surgery patients was enrolled. Patients were randomized to either control evaluation of PIVC dwell or to receive daily PIVO blood collections in addition to evaluation of PIVC dwell. Daily PIVO blood collections did not negatively affect PIVC dwell or replacement rates. Overall 81% of blood collection attempts were successful and the likelihood of success was strongly associated with PIVC condition. Patients reported 0.7/10 pain for PIVO blood collection on a 0-10 pain scale and a 9.1/10 preference for PIVO on a 0 (strongly prefer needle) to 10 (strongly prefer PIVO) preference scale. Results suggest that use of a PIV based blood collection was a reliable and valid approach and was superior to routine phlebotomy in self-reported responses from patients. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Stable RNA markers for identification of blood and saliva stains revealed from whole genome expression analysis of time-wise degraded samples

    PubMed Central

    Zubakov, Dmitry; Hanekamp, Eline; Kokshoorn, Mieke; van IJcken, Wilfred

    2007-01-01

    Human body fluids such as blood and saliva represent the most common source of biological material found at a crime scene. Reliable tissue identification in forensic science can reveal significant insights into crime scene reconstruction and can thus contribute toward solving crimes. Limitations of existing presumptive tests for body fluid identification in forensics, which are usually based on chemoluminescence or protein analysis, are expected to be overcome by RNA-based methods, provided that stable RNA markers with tissue-specific expression patterns are available. To generate sets of stable RNA markers for reliable identification of blood and saliva stains we (1) performed whole-genome gene expression analyses on a series of time-wise degraded blood and saliva stain samples using the Affymetrix U133 plus2 GeneChip, (2) consulted expression databases to obtain additional information on tissue specificity, and (3) confirmed expression patterns of the most promising candidate genes by quantitative real-time polymerase chain reaction including additional forensically relevant tissues such as semen and vaginal secretion. Overall, we identified nine stable mRNA markers for blood and five stable mRNA markers for saliva detection showing tissue-specific expression signals in stains aged up to 180 days of age, expectedly older. Although, all of the markers were able to differentiate blood/saliva from semen samples, none of them could differentiate vaginal secretion because of the complex nature of vaginal secretion and the biological similarity of buccal and vaginal mucosa. We propose the use of these 14 stable mRNA markers for identification of blood and saliva stains in future forensic practice. Electronic supplementary material The online version of this article (doi:10.1007/s00414-007-0182-6) contains supplementary material, which is available to authorized users. PMID:17579879

  16. Performance characteristics of the ARCHITECT anti-HCV assay.

    PubMed

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  17. Placental cadmium as an additional noninvasive bioindicator of active maternal tobacco smoking.

    PubMed

    Piasek, Martina; Jurasović, Jasna; Sekovanić, Ankica; Brajenović, Nataša; Brčić Karačonji, Irena; Mikolić, Anja; Grgec, Antonija Sulimanec; Stasenko, Sandra

    2016-01-01

    Tobacco smoke (TS) is a mixture of chemicals that is known to exert carcinogenic and endocrine-disrupting effects, as well as adverse effects on various systems. In TS nicotine is the major alkaloid and cadmium (Cd) the most abundant metal ion. The aim of this investigation was to assess exposure to Cd attributed to TS in healthy postpartum subjects (mean age 28 years) after term vaginal delivery in a clinical hospital by determining metal levels in maternal blood, placenta, and cord blood in relation to nicotine in maternal hair (12-cm-long samples). Two study groups were compared based upon self-reporting data: smokers (n = 32; continual cigarette smoking 3 months before and 9 months during pregnancy) and nonsmokers (n = 54; including passive smokers whose parameters did not differ from unexposed nonsmokers). In smokers compared to nonsmokers maternal hair nicotine concentrations increased approximately sevenfold, while Cd levels rose fourfold in maternal blood and up to twofold in placenta. Significant positive correlations were noted between maternal hair nicotine and placental Cd, maternal hair nicotine and maternal blood Cd, and placental Cd and maternal blood Cd. Levels of cord blood Cd were low in both study groups (<0.1 ng/ml). Data indicate that Cd in placenta may serve as a noninvasive bioindicator in addition to commonly used noninvasive hair nicotine in maternal TS assessment, especially in cases where unavailable or inappropriate (short or chemically treated) hair samples occur.

  18. Blood pressure associated with sleep-disordered breathing in a population sample of children.

    PubMed

    Bixler, Edward O; Vgontzas, Alexandros N; Lin, Hung-Mo; Liao, Duanping; Calhoun, Susan; Fedok, Fred; Vlasic, Vukmir; Graff, Gavin

    2008-11-01

    The current criteria for sleep-disordered breathing (SDB) in children are not based on a clinically relevant outcome. The purpose of this study was to assess the association of blood pressure with SDB in a random sample of the local elementary school children (kindergarten through grade 5) using a 2-phased strategy. During phase 1, a brief questionnaire was completed for all of the children (N=5740) with a response rate of 78.5%. During phase 2, 700 randomly selected children from phase 1 with a response rate of 70.0% were assessed with a full polysomnograph and a history/physical, including an ECG; ear, nose, and throat; and pulmonary evaluation. We observed a significantly elevated systolic blood pressure associated with the apnea hypopnea index (AHI): AHI >or=1 (2.9 mm Hg); AHI >or=3 (7.1 mm Hg); and AHI >or=5 (12.9 mm Hg). The SDB and blood pressure association remained significant after adjusting for age, sex, race, body mass index percentile or waist circumference, sleep efficiency, percentage of rapid eye movement sleep, and snoring. In addition, older age, body mass index percentile, waist circumference, and snoring were significantly associated with blood pressure, independent of SDB. Based on these findings, our study suggests that SDB is significantly associated with higher levels of systolic blood pressure in children aged 5 to 12 years even after adjusting for the various confounding factors. Clinically, the data support the threshold of AHI >or=5 for the initiation of treatment for SDB. Additional research is indicated to assess the efficacy of SDB treatment on reducing blood pressure.

  19. Dog erythrocyte antigens (DEA) 1, 4, 7 and suspected naturally occurring anti-DEA 7 antibodies in Italian Corso dogs.

    PubMed

    Spada, E; Proverbio, D; Priolo, V; Ippolito, D; Baggiani, L; Perego, R; Pennisi, M G

    2017-04-01

    We sought to determine the prevalence of dog erythrocyte antigen (DEA) 1, 4 and 7 and naturally occurring anti-DEA7 antibodies in Italian Corso dogs. In addition, we correlated DEAs with different epidemiologic variables, compared the prevalence of DEAs against other canine populations and assessed the risk of sensitisation and transfusion reactions (TRs) following unmatched transfusion. Blood samples from 100 Corso dogs were evaluated for DEA 1, 4, 7 and naturally occurring anti-DEA 7 antibodies. Seventy-one percent of samples were DEA 1-negative, 100% tested DEA 4-positive, and 95% tested DEA 7-negative. Suspected anti-DEA7 antibodies were found in 32% dogs. The DEA 1 and 7-negative phenotypes were significantly more common than in most canine populations. When a previously tested Italian canine population was considered as blood donors for Corso dogs, the risk of DEA 1 sensitisation using DEA 1 untyped blood was 29%, and of acute haemolytic TRs after a second untyped DEA 1-incompatible transfusion was 8%. The potential for delayed TRs between DEA 7-negative Corso dogs with suspected naturally occurring anti-DEA 7 antibodies receiving untyped DEA 7-positive blood was 11%. Conversely, when Corso dogs were blood donors for the same population, the risk of DEA 1 sensitisation was 17% and the risk of an acute haemolytic TR after a second DEA 1-incompatible blood transfusion was 3%. Corso dogs can be suitable blood donors. Additional studies are needed to clarify whether the high prevalence of naturally occurring anti-DEA 7 antibodies in this breed could increase their risk of delayed TRs when they are blood recipients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Pleomorphic Structures in Human Blood Are Red Blood Cell-Derived Microparticles, Not Bacteria.

    PubMed

    Mitchell, Adam J; Gray, Warren D; Schroeder, Max; Yi, Hong; Taylor, Jeannette V; Dillard, Rebecca S; Ke, Zunlong; Wright, Elizabeth R; Stephens, David; Roback, John D; Searles, Charles D

    2016-01-01

    Red blood cell (RBC) transfusions are a common, life-saving therapy for many patients, but they have also been associated with poor clinical outcomes. We identified unusual, pleomorphic structures in human RBC transfusion units by negative-stain electron microscopy that appeared identical to those previously reported to be bacteria in healthy human blood samples. The presence of viable, replicating bacteria in stored blood could explain poor outcomes in transfusion recipients and have major implications for transfusion medicine. Here, we investigated the possibility that these structures were bacteria. Flow cytometry, miRNA analysis, protein analysis, and additional electron microscopy studies strongly indicated that the pleomorphic structures in the supernatant of stored RBCs were RBC-derived microparticles (RMPs). Bacterial 16S rDNA PCR amplified from these samples were sequenced and was found to be highly similar to species that are known to commonly contaminate laboratory reagents. These studies suggest that pleomorphic structures identified in human blood are RMPs and not bacteria, and they provide an example in which laboratory contaminants may can mislead investigators.

  1. Lead and trace element levels in milk and blood of buffaloes (Bubalus bubalis) from Hyderabad, India.

    PubMed

    Shailaja, M; Reddy, Yathapu Srinivasa; Kalakumar, B D P; Brinda, S A; Manohar, Gottimukkula; Kumar, B Dinesh

    2014-06-01

    The presence of lead (Pb) in milk and its interaction with trace elements is a serious health concern. Present study is aimed at determining Pb and trace element (Fe, Zn and Mg) levels in milk and blood/serum samples of lactating buffaloes (Bubalus bubalis) living in a market-area (Group-A) and a dairy-experimental station (Group-B), Hyderabad, India. In addition, kidney and liver function tests were assessed. Fodder, milk and blood Pb levels were significantly (p < 0.01) higher in Group-B. Elevated Pb levels correlated positively with reduced Fe and Zn levels in both serum and milk. A significant (p < 0.01) positive correlation between blood Pb and milk Pb levels was observed. Kidney and liver function markers were significantly higher in Group-B buffaloes. The results suggest that contaminated fodder might be one of the responsible factors for elevated Pb levels. In addition, lower levels of Fe and Zn might have led to bioaccumulation of Pb in blood and milk.

  2. Detection of Classical swine fever virus infection by individual oral fluid of pigs following experimental inoculation.

    PubMed

    Petrini, Stefano; Pierini, Ilaria; Giammarioli, Monica; Feliziani, Francesco; De Mia, Gian Mario

    2017-03-01

    We evaluated the use of oral fluid as an alternative to serum samples for Classical swine fever virus (CSFV) detection. Individual oral fluid and serum samples were collected at different times post-infection from pigs that were experimentally inoculated with CSFV Alfort 187 strain. We found no evidence of CSFV neutralizing antibodies in swine oral fluid samples under our experimental conditions. In contrast, real-time reverse transcription-polymerase chain reaction could detect CSFV nucleic acid from the oral fluid as early as 8 d postinfection, which also coincided with the time of initial detection in blood samples. The probability of CSFV detection in oral fluid was identical or even higher than in the corresponding blood sample. Our results support the feasibility of using this sampling method for CSFV genome detection, which may represent an additional cost-effective tool for CSF control.

  3. Simultaneous detection of 15 antibiotic growth promoters in bovine muscle, blood and urine by UPLC-MS/MS.

    PubMed

    Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode

    2017-12-01

    An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.

  4. Method for extending the useful shelf-life of refrigerated red blood cells by flushing with inert gas

    DOEpatents

    Bitensky, M.W.; Yoshida, Tatsuro

    1997-04-29

    A method is disclosed using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4 C storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4 C for prolonged periods of time is achieved by removing oxygen from the red blood cells at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate. 4 figs.

  5. Sources of Blood Meals of Sylvatic Triatoma guasayana near Zurima, Bolivia, Assayed with qPCR and 12S Cloning

    PubMed Central

    Lucero, David E.; Ribera, Wilma; Pizarro, Juan Carlos; Plaza, Carlos; Gordon, Levi W.; Peña, Reynaldo; Morrissey, Leslie A.; Rizzo, Donna M.; Stevens, Lori

    2014-01-01

    Background In this study we compared the utility of two molecular biology techniques, cloning of the mitochondrial 12S ribosomal RNA gene and hydrolysis probe-based qPCR, to identify blood meal sources of sylvatic Chagas disease insect vectors collected with live-bait mouse traps (also known as Noireau traps). Fourteen T. guasayana were collected from six georeferenced trap locations in the Andean highlands of the department of Chuquisaca, Bolivia. Methodology/Principal Findings We detected four blood meals sources with the cloning assay: seven samples were positive for human (Homo sapiens), five for chicken (Gallus gallus) and unicolored blackbird (Agelasticus cyanopus), and one for opossum (Monodelphis domestica). Using the qPCR assay we detected chicken (13 vectors), and human (14 vectors) blood meals as well as an additional blood meal source, Canis sp. (4 vectors). Conclusions/Significance We show that cloning of 12S PCR products, which avoids bias associated with developing primers based on a priori knowledge, detected blood meal sources not previously considered and that species-specific qPCR is more sensitive. All samples identified as positive for a specific blood meal source by the cloning assay were also positive by qPCR. However, not all samples positive by qPCR were positive by cloning. We show the power of combining the cloning assay with the highly sensitive hydrolysis probe-based qPCR assay provides a more complete picture of blood meal sources for insect disease vectors. PMID:25474154

  6. Utility of blood pressure genetic risk score in admixed Hispanic samples.

    PubMed

    Beecham, A H; Wang, L; Vasudeva, N; Liu, Z; Dong, C; Goldschmidt-Clermont, P J; Pericak-Vance, M A; Rundek, T; Seo, D; Blanton, S H; Sacco, R L; Beecham, G W

    2016-12-01

    Hypertension is strongly influenced by genetic factors. Although hypertension prevalence in some Hispanic sub-populations is greater than in non-Hispanic whites, genetic studies on hypertension have focused primarily on samples of European descent. A recent meta-analysis of 200 000 individuals of European descent identified 29 common genetic variants that influence blood pressure, and a genetic risk score derived from the 29 variants has been proposed. We sought to evaluate the utility of this genetic risk score in Hispanics. The sample set consists of 1994 Hispanics from 2 cohorts: the Northern Manhattan Study (primarily Dominican/Puerto Rican) and the Miami Cardiovascular Registry (primarily Cuban/South American). Risk scores for systolic and diastolic blood pressure were computed as a weighted sum of the risk alleles, with the regression coefficients reported in the European meta-analysis used as weights. Association of risk score with blood pressure was tested within each cohort, adjusting for age, age 2 , sex and body mass index. Results were combined using an inverse-variance meta-analysis. The risk score was significantly associated with blood pressure in our combined sample (P=5.65 × 10 -4 for systolic and P=1.65 × 10 -3 for diastolic) but the magnitude of the effect sizes varied by degree of European, African and Native American admixture. Further studies among other Hispanic sub-populations are needed to elucidate the role of these 29 variants and identify additional genetic and environmental factors contributing to blood pressure variability in Hispanics.

  7. Relationship between vapor intrusion and human exposure to trichloroethylene.

    PubMed

    Archer, Natalie P; Bradford, Carrie M; Villanacci, John F; Crain, Neil E; Corsi, Richard L; Chambers, David M; Burk, Tonia; Blount, Benjamin C

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥ 0.012 µg L(-1)) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (P = 0.0002 and P = 0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 µg m(-3) were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (P < .0001; 95% CI 10.4-236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting.

  8. Relationship between vapor intrusion and human exposure to trichloroethylene

    PubMed Central

    ARCHER, NATALIE P.; BRADFORD, CARRIE M.; VILLANACCI, JOHN F.; CRAIN, NEIL E.; CORSI, RICHARD L.; CHAMBERS, DAVID M.; BURK, TONIA; BLOUNT, BENJAMIN C.

    2015-01-01

    Trichloroethylene (TCE) in groundwater has the potential to volatilize through soil into indoor air where it can be inhaled. The purpose of this study was to determine whether individuals living above TCE-contaminated groundwater are exposed to TCE through vapor intrusion. We examined associations between TCE concentrations in various environmental media and TCE concentrations in residents. For this assessment, indoor air, outdoor air, soil gas, and tap water samples were collected in and around 36 randomly selected homes; blood samples were collected from 63 residents of these homes. Additionally, a completed exposure survey was collected from each participant. Environmental and blood samples were analyzed for TCE. Mixed model multiple linear regression analyses were performed to determine associations between TCE in residents' blood and TCE in indoor air, outdoor air, and soil gas. Blood TCE concentrations were above the limit of quantitation (LOQ; ≥0.012 μg/L) in 17.5% of the blood samples. Of the 36 homes, 54.3%, 47.2%, and >84% had detectable concentrations of TCE in indoor air, outdoor air, and soil gas, respectively. Both indoor air and soil gas concentrations were statistically significantly positively associated with participants' blood concentrations (p=0.0002 and p=0.04, respectively). Geometric mean blood concentrations of residents from homes with indoor air concentrations of >1.6 μg/m3 were approximately 50 times higher than geometric mean blood TCE concentrations in participants from homes with no detectable TCE in indoor air (p<.0001; 95% CI 10.4 – 236.4). This study confirms the occurrence of vapor intrusion and demonstrates the magnitude of exposure from vapor intrusion of TCE in a residential setting. PMID:26259926

  9. Integrated quantitative phase and birefringence microscopy for imaging malaria-infected red blood cells.

    PubMed

    Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng

    2016-09-01

    A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.

  10. Integrated quantitative phase and birefringence microscopy for imaging malaria-infected red blood cells

    NASA Astrophysics Data System (ADS)

    Li, Chengshuai; Chen, Shichao; Klemba, Michael; Zhu, Yizheng

    2016-09-01

    A dual-modality birefringence/phase imaging system is presented. The system features a crystal retarder that provides polarization mixing and generates two interferometric carrier waves in a single signal spectrum. The retardation and orientation of sample birefringence can then be measured simultaneously based on spectral multiplexing interferometry. Further, with the addition of a Nomarski prism, the same setup can be used for quantitative differential interference contrast (DIC) imaging. Sample phase can then be obtained with two-dimensional integration. In addition, birefringence-induced phase error can be corrected using the birefringence data. This dual-modality approach is analyzed theoretically with Jones calculus and validated experimentally with malaria-infected red blood cells. The system generates not only corrected DIC and phase images, but a birefringence map that highlights the distribution of hemozoin crystals.

  11. Boron detection from blood samples by ICP-AES and ICP-MS during boron neutron capture therapy.

    PubMed

    Linko, S; Revitzer, H; Zilliacus, R; Kortesniemi, M; Kouri, M; Savolainen, S

    2008-01-01

    The concept of boron neutron capture therapy (BNCT) involves infusion of a (10)B containing tracer into the patient's bloodstream followed by local neutron irradiation(s). Accurate estimation of the blood boron level for the treatment field before irradiation is required. Boron concentration can be quantified by inductively coupled plasma atomic emission spectrometry (ICP-AES), mass spectrometry (ICP-MS), spectrofluorometric and direct current atomic emission spectrometry (DCP-AES) or by prompt gamma photon detection methods. The blood boron concentrations were analysed and compared using ICP-AES and ICP-MS to ensure congruency of the results if the analysis had to be changed during the treatment, e.g. for technical reasons. The effect of wet-ashing on the results was studied in addition. The mean of all samples analysed with ICP-MS was 5.8 % lower than with ICP-AES coupled to wet-ashing (R (2) = 0.88). Without wet-ashing, the mean of all samples analysed with ICP-MS was 9.1 % higher than with ICP-AES (R (2) = 0.99). Boron concentration analysed from whole blood samples with ICP-AES correlated well with the values of ICP-MS with wet-ashing of the sample matrix, which is generally considered the reference method. When using these methods in parallel at certain intervals during the treatments, reliability of the blood boron concentration values remains satisfactory, taking into account the required accuracy of dose determination in the irradiation of cancer patients.

  12. First confirmed report of outbreak of theileriosis/anaplasmosis in a cattle farm in Henan, China.

    PubMed

    Cui, Yanyan; Wang, Xiaoxing; Zhang, Yan; Yan, Yaqun; Dong, Haiju; Jian, Fuchun; Shi, Ke; Zhang, Longxian; Wang, Rongjun; Ning, Changshen

    2018-01-01

    Tick-borne diseases (TBDs) impose a significant constraint to livestock production world widely. In this paper, we presented a case of TBD in a cattle farm in Henan, China. 35 blood samples (7 samples sent by veterinarian, 28 samples gathered by our colleagues) were collected from ill, surviving and asymptomatic cattle and microscopic observation and PCR assays were conducted to characterize the pathogens. Genus Ixodes feeding on these cattle were collected and identified. Theileria annulata-like and Anaplasma marginale-like pathogens were observed in the blood smears stained with Giemsa staining under microscope. Furthermore, 5 out of 7 cattle blood samples were found to be positive for T. annulata by PCR. In the 28 blood specimens, three were positive for T. annulata, while A. marginale DNA was detected in nine blood DNA samples. Besides, 56 ticks feeding on cattle were collected from this farm and were all identified as Rhipisephalus microplus, meanwhile, 10 of them were found to be positive for A. marginale. In addition, phylogenetic analysis of the msp4 gene sequences of A. marginale obtained in this study showed that the isolate from cattle (KX840009) fell in the same clade with that of R. microplus (KX904527), sharing 100% similarity. To the best of our knowledge, this is the first confirmed report of outbreak of theileriosis/anaplasmosis in cattle farms in Henan, China. Copyright © 2017. Published by Elsevier B.V.

  13. Blood as a route of transmission of uterine pathogens from the gut to the uterus in cows.

    PubMed

    Jeon, Soo Jin; Cunha, Federico; Vieira-Neto, Achilles; Bicalho, Rodrigo C; Lima, Svetlana; Bicalho, Marcela L; Galvão, Klibs N

    2017-08-25

    Metritis is an inflammatory disease of the uterus caused by bacterial infection, particularly Bacteroides, Porphyromonas, and Fusobacterium. Bacteria from the environment, feces, or vagina are believed to be the only sources of uterine contamination. Blood seeps into the uterus after calving; therefore, we hypothesized that blood could also be a seeding source of uterine bacteria. Herein, we compared bacterial communities from blood, feces, and uterine samples from the same cows at 0 and 2 days postpartum using deep sequencing and qPCR. The vaginal microbiome 7 days before calving was also compared. There was a unique structure of bacterial communities by sample type. Principal coordinate analysis revealed two distinct clusters for blood and feces, whereas vaginal and uterine bacterial communities were more scattered, indicating greater variability. Cluster analysis indicated that uterine bacterial communities were more similar to fecal bacterial communities than vaginal and blood bacterial communities. Nonetheless, there were core genera shared by all blood, feces, vaginal, and uterine samples. Major uterine pathogens such as Bacteroides, Porphyromonas, and Fusobacterium were part of the core genera in blood, feces, and vagina. Other uterine pathogens such as Prevotella and Helcococcus were not part of the core genera in vaginal samples. In addition, uterine pathogens showed a strong and significant interaction with each other in the network of blood microbiota, but not in feces or vagina. These microbial interactions in blood may be an important component of disease etiology. The copy number of total bacteria in blood and uterus was correlated; the same did not occur in other sites. Bacteroides heparinolyticus was more abundant in the uterus on day 0, and both B. heparinolyticus and Fusobacterium necrophorum were more abundant in the uterus than in the blood and feces on day 2. This indicates that B. heparinolyticus has a tropism for the uterus, whereas both pathogens thrive in the uterine environment early postpartum. Blood harbored a unique microbiome that contained the main uterine pathogens such as Bacteroides, Porphyromonas, and Fusobacterium. The presence of these pathogens in blood shortly after calving shows the feasibility of hematogenous spread of uterine pathogens in cows.

  14. Developing an Apicomplexan DNA Barcoding System to Detect Blood Parasites of Small Coral Reef Fishes.

    PubMed

    Renoux, Lance P; Dolan, Maureen C; Cook, Courtney A; Smit, Nico J; Sikkel, Paul C

    2017-08-01

    Apicomplexan parasites are obligate parasites of many species of vertebrates. To date, there is very limited understanding of these parasites in the most-diverse group of vertebrates, actinopterygian fishes. While DNA barcoding targeting the eukaryotic 18S small subunit rRNA gene sequence has been useful in identifying apicomplexans in tetrapods, identification of apicomplexans infecting fishes has relied solely on morphological identification by microscopy. In this study, a DNA barcoding method was developed that targets the 18S rRNA gene primers for identifying apicomplexans parasitizing certain actinopterygian fishes. A lead primer set was selected showing no cross-reactivity to the overwhelming abundant host DNA and successfully confirmed 37 of the 41 (90.2%) microscopically verified parasitized fish blood samples analyzed in this study. Furthermore, this DNA barcoding method identified 4 additional samples that screened negative for parasitemia, suggesting this molecular method may provide improved sensitivity over morphological characterization by microscopy. In addition, this PCR screening method for fish apicomplexans, using Whatman FTA preserved DNA, was tested in efforts leading to a more simplified field collection, transport, and sample storage method as well as a streamlining sample processing important for DNA barcoding of large sample sets.

  15. Periconceptional maternal micronutrient supplementation is associated with widespread gender related changes in the epigenome: a study of a unique resource in the Gambia.

    PubMed

    Khulan, Batbayar; Cooper, Wendy N; Skinner, Benjamin M; Bauer, Julien; Owens, Stephen; Prentice, Andrew M; Belteki, Gusztav; Constancia, Miguel; Dunger, David; Affara, Nabeel A

    2012-05-01

    In addition to the genetic constitution inherited by an organism, the developmental trajectory and resulting mature phenotype are also determined by mechanisms acting during critical windows in early life that influence and establish stable patterns of gene expression. This is the crux of the developmental origins of health and disease hypothesis that suggests undernutrition during gestation and infancy predisposes to ill health in later life. The hypothesis that periconceptional maternal micronutrient supplementation might affect fetal genome-wide methylation within gene promoters was explored in cord blood samples from offspring of Gambian women enrolled into a unique randomized, double blind controlled trial. Significant changes in the epigenome in cord blood DNA samples were further explored in a subset of offspring at 9 months. Gender-specific changes related to periconceptional nutritional supplementation were identified in cord blood DNA samples, some of which showed persistent changes in infant blood DNA samples. Significant effects of periconceptional micronutrient supplementation were also observed in postnatal samples which were not evident in cord blood. In this Gambian population, the increased death rate of individuals born in nutritionally poor seasons has been related to infection and it is of interest that we identified differential methylation at genes associated with defence against infection and immune response. Although the sample size was relatively small, these pilot data suggest that periconceptional nutrition in humans is an important determinant of newborn whole genome methylation patterns but may also influence postnatal developmental patterns of gene promoter methylation linking early with disease risk.

  16. Drop-to-drop solvent microextraction coupled with gas chromatography/mass spectrometry for rapid determination of trimeprazine in urine and blood of rats: application to pharmacokinetic studies.

    PubMed

    Agrawal, Kavita; Wu, Hui-Fen

    2007-01-01

    A simple and rapid method based on drop-to-drop solvent microextraction (DDSME) coupled with gas chromatography/mass spectrometry (GC/MS) has been successfully applied for the pharmacokinetic studies of trimeprazine in 8 microL of urine and blood samples of rats. Several factors that influenced the extraction efficiency of DDSME, such as selection of organic solvent, extraction time, exposure volume of organic phase, addition of salt and pH, were optimized. Linearity was obtained over the concentration ranges of 0.2-10, 0.25-7.0 and 0.5-6.0 microg/mL with correlation coefficients of 0.998, 0.996 and 0.993 in deionized water, urine and blood samples of rats, respectively. The limits of detection (LODs) of trimeprazine were 0.05, 0.06 and 0.1 microg/mL in deionized water, urine and blood samples. The concentrations of trimeprazine obtained in urine and blood samples of rats were 0.21-1.25 and 2.72-0.22 microg/mL, respectively, after a single intravenous administration of this drug. The enrichment factors and LOD values obtained by DDSME coupled to GC/MS were compared with those of hollow fiber liquid-phase microextraction (HF-LPME) combined with GC/MS. We believe that this novel approach can be very useful in clinical application since only one microdrop of biological samples was required to perform the pharmacokinetic studies from rats, so the sample pretreatments for animal experiments can be very easy too. Copyright (c) 2007 John Wiley & Sons, Ltd.

  17. Reducing the risk of fatal and disabling hypoglycaemia: a comparison of arterial blood sampling systems.

    PubMed

    Brennan, K A; Eapen, G; Turnbull, D

    2010-04-01

    In 2008, the National Patient Safety Agency (NPSA) published a report after 42 incidents and two deaths where glucose-containing flush solutions were attached to the arterial line. The molar concentration of 5% glucose is 277 mmol litre(-1). Only a tiny amount of sample contamination will lead to an artificially high glucose. As the NPSA sought a solution, a bench model was constructed to compare the performance of three open and three closed arterial line systems in limiting sample contamination. All arterial line systems were set up in a standard manner and pressurized to 300 mm Hg with 5% glucose used as the flush solution. This was connected to the 'radial artery' using an 18 G needle representing the radial cannula. The radial artery was simulated using a wide-bore extension set with 'blood' flow at 60 ml min(-1). Blood was simulated by the addition of red dye to Hartmann's solution. Increasing multiples of arterial line dead space were aspirated and discarded. Blood samples were then obtained and glucose concentration was measured. Significant glucose contamination (3 mmol litre(-1) +/-3.4) was detected in all open arterial line systems up to an aspiration volume of five times the dead space. No samples from the closed systems recorded glucose concentration >1 mmol litre(-1). Recommended minimal discard volumes are inadequate in the presence of glucose as the flush solution and can lead to high blood glucose readings, inappropriate insulin use, and iatrogenic neuroglycopaenia. Our study demonstrates that the closed-loop arterial sampling system could be the universal solution sought by the NPSA.

  18. Comparative analysis of blood and saliva expression profiles in chronic and refractory periodontitis patients.

    PubMed

    Zhang, Bin; Lin, Ting; He, Hong

    2015-12-24

    This study aimed to identify characteristic representative genes through a comparative analysis of gene expression profiles in the blood and saliva of chronic periodontitis (CP) and refractory periodontitis (RP) patients to provide new treatment strategies that may be helpful in the treatment of different forms of periodontitis. GSE43525 was downloaded from Gene Expression Omnibus. In the dataset, thirteen samples were from blood including 4 controls, 4 CP and 5 RP samples, and ten samples were from saliva including 3 controls, 4 CP and 3 RP samples. After comparing the CP and RP samples, differentially expressed genes (DEGs) between these two types of periodontitis in the blood and saliva samples were identified by an LIMMA package. Then, functional and pathway enrichment analyses were performed by DAVID and KOBAS, respectively. The significantly associated miRNAs in CP and RP were searched by WebGestalt. In total, 213 DEGs in CP and 45 DEGs in RP were identified. Functional enrichment showed that the DEGs of CP were mainly enriched in ribosome and regulation of apoptosis-related pathways in blood as well as saliva, while the DEGs of RP were significantly enriched in immune responses and response to organic substance-related pathways. Several miRNAs, such as miR-381 and miR-494, were identified as being closely associated with CP. In addition, CD24, EST1, MTSS1, ING3, CCND2 and SYNE2 might be potential targets for diagnosis and treatment of CP. The identified DEGs and miRNAs might be potential targets for the treatment of chronic and refractory periodontitis.

  19. Toxicodynamic analysis of the combined cholinesterase inhibition by paraoxon and methamidophos in human whole blood

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bosgra, Sieto; Eijkeren, Jan C.H. van; Schans, Marcel J. van der

    2009-04-01

    Theoretical work has shown that the isobole method is not generally valid as a method for testing the absence or presence of interaction (in the biochemical sense) between chemicals. The present study illustrates how interaction can be tested by fitting a toxicodynamic model to the results of a mixture experiment. The inhibition of cholinesterases (ChE) in human whole blood by various dose combinations of paraoxon and methamidophos was measured in vitro. A toxicodynamic model describing the processes related to both OPs in inhibiting AChE activity was developed, and fit to the observed activities. This model, not containing any interaction betweenmore » the two OPs, described the results from the mixture experiment well, and it was concluded that the OPs did not interact in the whole blood samples. While this approach of toxicodynamic modeling is the most appropriate method for predicting combined effects, it is not rapidly applicable. Therefore, we illustrate how toxicodynamic modeling can be used to explore under which conditions dose addition would give an acceptable approximation of the combined effects from various chemicals. In the specific case of paraoxon and methamidophos in whole blood samples, it was found that dose addition gave a reasonably accurate prediction of the combined effects, despite considerable difference in some of their rate constants, and mildly non-parallel dose-response curves. Other possibilities of validating dose-addition using toxicodynamic modeling are briefly discussed.« less

  20. Modelling antecedents of blood donation motivation among non-donors of varying age and education.

    PubMed

    Lemmens, K P H; Abraham, C; Ruiter, R A C; Veldhuizen, I J T; Dehing, C J G; Bos, A E R; Schaalma, H P

    2009-02-01

    Understanding blood donation motivation among non-donors is prerequisite to effective recruitment. Two studies explored the psychological antecedents of blood donation motivation and the generalisability of a model of donation motivation across groups differing in age and educational level. An older well-educated population and a younger less well-educated population were sampled. The studies assessed the role of altruism, fear of blood/needles and donation-specific cognitions including attitudes and normative beliefs derived from an extended theory of planned behaviour (TPB). Across both samples, results showed that affective attitude, subjective norm, descriptive norm, and moral norm were the most important correlates of blood donation intentions. Self-efficacy was more important among the younger less well-educated group. Altruism was related to donation motivation but only indirectly through moral norm. Similarly, fear of blood/needles only had an indirect effect on motivation through affective attitude and self-efficacy. Additional analyses with the combined data set found no age or education moderation effects, suggesting that this core model of donation-specific cognitions can be used to inform future practical interventions recruiting new blood donors in the general population.

  1. Transmission of molecularly undetectable circulating parasite clones leads to high infection complexity in mosquitoes post feeding.

    PubMed

    Grignard, Lynn; Gonçalves, Bronner P; Early, Angela M; Daniels, Rachel F; Tiono, Alfred B; Guelbéogo, Wamdaogo M; Ouédraogo, Alphonse; van Veen, Elke M; Lanke, Kjerstin; Diarra, Amidou; Nebie, Issa; Sirima, Sodiomon B; Targett, Geoff A; Volkman, Sarah K; Neafsey, Daniel E; Wirth, Dyann F; Bousema, Teun; Drakeley, Chris

    2018-05-05

    Plasmodium falciparum malaria infections often comprise multiple distinct parasite clones. Few datasets have directly assessed infection complexity in humans and mosquitoes they infect. Examining parasites using molecular tools may provide insights into the selective transmissibility of isolates. Using capillary electrophoresis genotyping and next generation amplicon sequencing, we analysed complexity of parasite infections in human blood and in the midguts of mosquitoes that became infected in membrane feeding experiments using the same blood material in two West African settings. Median numbers of clones in humans and mosquitoes were higher in samples from Burkina Faso (4.5, interquartile range 2-8 for humans; and 2, interquartile range 1-3 for mosquitoes) than in The Gambia (2, interquartile range 1-3 and 1, interquartile range 1-3, for humans and mosquitoes, respectively). Whilst the median number of clones was commonly higher in human blood samples, not all transmitted alleles were detectable in the human peripheral blood. In both study sample sets, additional parasite alleles were identified in mosquitoes compared with the matched human samples (10-88.9% of all clones/feeding assay, n = 73 feeding assays). The results are likely due to preferential amplification of the most abundant clones in peripheral blood but confirm the presence of low density clones that produce transmissible sexual stage parasites. Copyright © 2018. Published by Elsevier Ltd.

  2. Evaluation of automated loop-mediated amplification (LAMP) for routine malaria detection in blood samples of German travelers - A cross-sectional study.

    PubMed

    Frickmann, Hagen; Hinz, Rebecca; Rojak, Sandra; Bonow, Insa; Ruben, Stefanie; Wegner, Christine; Zielke, Iris; Hagen, Ralf Matthias; Tannich, Egbert

    2018-05-12

    We assessed a commercial loop-mediated amplification (LAMP) platform for its reliability as a screening tool for malaria parasite detection. A total of 1000 blood samples from patients with suspected or confirmed malaria submitted to the German National Reference Center for Tropical Pathogens were subjected to LAMP using the Meridian illumigene Malaria platform. Results were compared with microscopy from thick and thin blood films in all cases. In case of discordant results between LAMP and microscopy (n = 60), confirmation testing was performed with real-time PCR. Persistence of circulating parasite DNA was analyzed by serial assessments of blood samples following malaria treatment. Out of 1000 blood samples analyzed, 238 were positive for malaria parasites according to microscopy (n = 181/1000) or PCR (additional n = 57/60). LAMP demonstrated sensitivity of 98.7% (235/238), specificity of 99.6% (759/762), positive predictive value (PPV) of 98.7% (235/238) and negative predictive value (NPV) of 99.6% (759/762), respectively. For first slides of patients with malaria and for follow-up slides, sensitivity values were 99.1% (106/107) and 98.5% (129/131), respectively. The performance of the Meridian illumigene Malaria platform is suitable for initial screening of patients suspected of clinical malaria. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Manual versus automated blood sampling: impact of repeated blood sampling on stress parameters and behavior in male NMRI mice

    PubMed Central

    Kalliokoski, Otto; Sørensen, Dorte B; Hau, Jann; Abelson, Klas S P

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters measured, and expressed less anxious behavior. We conclude that repeated blood sampling by automated blood sampling and from the tail vein is less stressful than cheek blood sampling. The choice between automated blood sampling and tail blood sampling should be based on the study requirements, the resources of the laboratory and skills of the staff. PMID:24958546

  4. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    PubMed

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all p<0.05). Although alkaline phosphatase, total bilirubin and hemoglobin reached statistical significance (p=0.009, 0.027 and 0.012, respectively), all had very low average bias which ranged from 0.01% to 2%. Potassium, total hemoglobin and percent deoxyhemoglobin were statistically significant for the neonatal capillary tube study (p=0.011, 0.033 and 0.041, respectively) but no biases greater than ±4% were identified for these parameters. All observed differences of these 48 laboratory tests were not clinically significant. The modern PTS investigated in this study is acceptable for reliable sample delivery for routine chemistry, hematology, coagulation and blood gas (in syringe and capillary tube) laboratory tests.

  5. Quantitative analysis of genomic DNA degradation in whole blood under various storage conditions for molecular diagnostic testing.

    PubMed

    Permenter, Jessalyn; Ishwar, Arjun; Rounsavall, Angie; Smith, Maddie; Faske, Jennifer; Sailey, Charles J; Alfaro, Maria P

    2015-12-01

    Proper storage of whole blood is crucial for isolating nucleic acids from leukocytes and to ensure adequate performance of downstream assays in the molecular diagnostic laboratory. Short-term and long-term storage recommendations are lacking for successful isolation of genomic DNA (gDNA). Container type (EDTA or heparin), temperature (4 °C and room temperature) and time (1-130 days) were assessed as criterion for sample acceptance policies. The percentage of integrated area (%Ti) between 150 and 10,000 bp from the 2200 TapeStation electropherogram was calculated to measure gDNA degradation. Refrigerated EDTA samples yielded gDNA with low %Ti (high quality). Heparinized samples stored at room temperature yielded gDNA of worst quality. Downstream analysis demonstrated that the quality of the gDNA correlated with the quality of the data; samples with high %Ti generated significantly lower levels of high molecular weight amplicons. Recommendations from these analyses include storing blood samples intended for nucleic acid isolation in EDTA tubes at 4 °C for long term storage (>10 days). gDNA should be extracted within 3 days when blood is stored at room temperature regardless of the container. Finally, refrigerated heparinized samples should not be stored longer than 9 days if expecting high quality gDNA isolates. Laboratories should consider many factors, in addition to the results obtained herein, to update their policies for sample acceptance for gDNA extraction intended for molecular genetic testing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Rapid Point of Care Analyzer for the Measurement of Cyanide in Blood

    PubMed Central

    Ma, Jian; Ohira, Shin-Ichi; Mishra, Santosh K.; Puanngam, Mahitti; Dasgupta, Purnendu K.; Mahon, Sari B.; Brenner, Matthew; Blackledge, William; Boss, Gerry R.

    2011-01-01

    A simple, sensitive optical analyzer for the rapid determination of cyanide in blood in point of care applications is described. HCN is liberated by the addition of 20% H3PO4 and is absorbed by a paper filter impregnated with borate-buffered (pH 9.0) hydroxoaquocobinamide Hereinafter called cobinamide). Cobinamide on the filter changes color from orange (λmax = 510 nm) to violet (λmax = 583 nm) upon reaction with cyanide. This color change is monitored in the transmission mode by a light emitting diode (LED) with a 583 nm emission maximum and a photodiode detector. The observed rate of color change increases 10x when the cobinamide solution for filter impregnation is prepared in borate-buffer rather than in water. The use of a second LED emitting at 653 nm and alternate pulsing of the LEDs improve the limit of detection by 4x to ~ 0.5 μM for a 1 mL blood sample. Blood cyanide levels of imminent concern (≥ 10 μM) can be accurately measured in ~ 2 min. The response is proportional to the mass of cyanide in the sample – smaller sample volumes can be successfully used with proportionate change in the concentration LODs. Bubbling air through the blood-acid mixture was found effective for mixing of the acid with the sample and the liberation of HCN. A small amount of ethanol added to the top of the blood was found to be the most effective means to prevent frothing during aeration. The relative standard deviation (RSD) for repetitive determination of blood samples containing 9 μM CN was 1.09% (n=5). The technique was compared blind with a standard microdiffusion-spectrophotometric method used for the determination of cyanide in rabbit blood. The results showed good correlation (slope 1.05, r2 0.9257); independent calibration standards were used. PMID:21553921

  7. Universal pooled plasma (Uniplas(®)) does not induce complement-mediated hemolysis of human red blood cells in vitro.

    PubMed

    Heger, Andrea; Brandstätter, Hubert; Prager, Bettina; Brainovic, Janja; Cortes, Rhoda; Römisch, Jürgen

    2015-02-01

    Pooling of plasma of different blood groups before large scale manufacturing of Uniplas(®) results in the formation of low levels of soluble immune complexes (CIC). The aim of this study was to investigate the level and removal of CIC during Uniplas(®) manufacturing. In addition, an in vitro hemolysis assay should be developed and investigate if Uniplas(®) does induce complement-mediated hemolysis of human red blood cells (RBC). In-process samples from Uniplas(®) (universal plasma) and Octaplas(LG)(®) (blood group specific plasma) routine manufacturing batches were tested on CIC using commercially available ELISA test kits. In addition, CIC was produced by admixing heat-aggregated immunoglobulins or monoclonal anti-A/anti-B antibodies to plasma and removal of CIC was followed in studies of the Uniplas(®) manufacturing process under down-scale conditions. The extent of RBC lysis was investigated in plasma samples using the in-house hemolysis assay. Levels of CIC in Uniplas(®) are within the normal ranges for plasma and comparable to that found in Octaplas(LG)(®). Down-scale experiments showed that both IgG/IgM-CIC levels are significantly removed on average by 40-50% during Uniplas(®) manufacturing. Uniplas(®) does not induce hemolysis of RBCs in vitro. Hemolysis occurs only after spiking with high titers of anti-A/anti-B antibodies and depends on the antibody specificity (i.e. titer) in the plasma sample. The results of this study confirm the safety of Uniplas(®) regarding transfusion to patients of all ABO blood groups. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. American Black Bears as Hosts of Blacklegged Ticks (Acari: Ixodidae) in the Northeastern United States.

    PubMed

    Zolnik, Christine P; Makkay, Amanda M; Falco, Richard C; Daniels, Thomas J

    2015-09-01

    Ticks and whole blood were collected from American black bears (Ursus americanus Pallas) between October 2011 and October 2012 across four counties in northwestern New Jersey, an area where blacklegged ticks (Ixodes scapularis Say) and their associated tick-borne pathogens are prevalent. Adult American dog ticks (Dermacentor variabilis Say) were the most frequently collected tick species in late spring, whereas adult and nymphal blacklegged ticks were found in both the late spring and fall months. Additionally, for blacklegged ticks, we determined the quality of bloodmeals that females acquired from black bears compared with bloodmeals from white-tailed deer (Odocoileus virginianus Zimmerman), the most important host for the adult stage of this tick species. Measures of fecundity after feeding on each host species were not significantly different, suggesting that the bloodmeal a female blacklegged tick acquires from a black bear is of similar quality to that obtained from a white-tailed deer. These results establish the American black bear as both a host and quality bloodmeal source to I. scapularis. Thus, black bears may help support blacklegged tick populations in areas where they are both present. In addition, samples of black bear blood were tested for DNA presence of three tick-borne pathogens. Anaplasma phagocytophilum Foggie and Babesia microti Franca were found in 9.2 and 32.3% of blood samples, respectively. All blood samples were quantitative polymerase chain reaction-negative for Borrelia burgdorferi Johnson, Schmid, Hyde, Steigerwalt, & Brenner. Although circulating pathogens were found in blood, the status of black bears as reservoirs for these pathogens remains unknown. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Increased interleukin-11 levels in thoracic aorta and plasma from patients with acute thoracic aortic dissection.

    PubMed

    Xu, Yao; Ye, Jing; Wang, Menglong; Wang, Yuan; Ji, Qingwei; Huang, Ying; Zeng, Tao; Wang, Zhen; Ye, Di; Jiang, Huimin; Liu, Jianfang; Lin, Yingzhong; Wan, Jun

    2018-06-01

    Interleukin (IL) 11 is closely related to tumor and hematological system diseases. Recent studies have demonstrated that IL-11 also participates in cardiovascular diseases, including ischemia-reperfusion mediated heart injury and acute myocardial infarction. This study aimed to investigate whether IL-11 is involved in acute thoracic aortic dissection (TAD). Aortic tissue samples from normal donors and acute TAD patients were collected, and the expression of IL-11 in all aortic tissue was analyzed. In addition, blood samples from patients with chest pain were collected and divided into a non-AD (NAD) group and a TAD group according to the results of computed tomography angiography of the thoracic aorta. The plasma IL-11, IL-17 and interferon (IFN) γ in all blood samples were measured. Compared with aortic tissue of normal controls, IL-11 was significantly increased in aortic tissue of acute TAD patients, especially in the torn section. The IL-11 was derived from aorta macrophages in TAD. In addition, the plasma IL-11, IL-17 and IFN-γ were significantly higher in acute TAD patients than in NAD patients, and the correlation analysis showed that IL-11 levels were positively correlated with levels of IFN-γ, IL-17, glucose, systolic blood pressure, diastolic blood pressure, white blood cells, C-reactive proteins and D-dimers. Binary logistic regression analyses showed that elevated IL11 in patients who may have diagnostic value of TAD, but less that D-dimer. IL-11 was increased in thoracic aorta and plasma of TAD patients and may be a promising biomarker for diagnosis in patients with TAD. Copyright © 2018. Published by Elsevier B.V.

  10. Empirical modelling to predict the refractive index of human blood.

    PubMed

    Yahya, M; Saghir, M Z

    2016-02-21

    Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient's condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galvin, M.J.; MacNichols, G.L.; McRee, D.I.

    In this study, the influence of 2450 MHz CW microwave radiation on hematopoiesis in pregnant mice was examined. Dams (mice CD-1 strain) were irradiated during Days 1-6 or 6-15 of pregnancy. The animals were irradiated for a total of 8 hr per day at an average power density of 30 mW/cm/sup 2/. Peripheral blood and bone marrow samples were obtained on Day 18 of pregnancy. The total leukocyte and differential leukocyte counts of peripheral blood samples were not affected by either exposure regimen. In addition, no effects were noted in either the erythroid or myeloid mitotic indices of bone marrowmore » samples. Exposure of pregnant mice to microwave radiation under the conditions of these experiments had no effects on the investigated aspects of hematopoiesis.« less

  12. Pharmacokinetic Studies of Chinese Medicinal Herbs Using an Automated Blood Sampling System and Liquid Chromatography-mass Spectrometry.

    PubMed

    Wu, Yu-Tse; Wu, Ming-Tsang; Lin, Chia-Chun; Chien, Chao-Feng; Tsai, Tung-Hu

    2012-01-01

    The safety of herbal products is one of the major concerns for the modernization of traditional Chinese medicine, and pharmacokinetic data of medicinal herbs guide us to design the rational use of the herbal formula. This article reviews the advantages of the automated blood sampling (ABS) systems for pharmacokinetic studies. In addition, three commonly used sample preparative methods, protein precipitation, liquid-liquid extraction and solid-phase extraction, are introduced. Furthermore, the definition, causes and evaluation of matrix effects in liquid chromatography-mass spectrometry (LC/MS) analysis are demonstrated. Finally, we present our previous works as practical examples of the application of ABS systems and LC/MS for the pharmacokinetic studies of Chinese medicinal herbs.

  13. Cortisol in saliva and plasma of cattle after ACTH administration and milking.

    PubMed

    Negrão, J A; Porcionato, M A; de Passillé, A M; Rushen, J

    2004-06-01

    Interest in the measurement of salivary cortisol has increased recently because saliva can be easily collected before and after an imposed stress. This study evaluated the relationship between plasma and salivary concentrations of cortisol following ACTH administration in calves (experiment 1) and machine milking of adult cows (experiment 2). A catheter was inserted into the jugular vein of all animals 72 h before the beginning of experiments. Blood and saliva samples were collected before and after ACTH administration (0.6 IU/kg BW) in calves or before and after machine milking of cows. Using a cotton swab, each saliva sample was taken immediately following the blood sample. In general, cortisol profiles were similar in plasma and saliva and correlated in both experiments; however, plasma concentrations were significantly higher than salivary concentrations. In addition, the differences between cortisol concentrations measured in saliva and plasma within each experiment varied substantially between animals and samples. Furthermore, in experiment 2, nearly 10% of salivary samples were below limits of detection. The sharp peaks in cortisol after ACTH administration in both the plasma and saliva were reflected adrenal stimulation. In addition, increases in cortisol in response to milking in both the plasma and saliva suggest that salivary sampling is a reliable option when studying cortisol responses to normal physiological events.

  14. Measurement of β-hydroxybutyrate in capillary blood obtained from an ear to detect hyperketonemia in dairy cows by using an electronic handheld device.

    PubMed

    Süss, D; Drillich, M; Klein-Jöbstl, D; Wagener, K; Krieger, S; Thiel, A; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-09-01

    The primary objective of the present study was to test whether capillary blood obtained by puncturing the skin of an ear with a minimal invasive lancet technique is able to detect hyperketonemia (HYK) in dairy cows. Furthermore, test characteristics of a new available handheld device, the FreeStyle Precision Neo (FSP-Neo, Abbott GmbH & Co. KG, Wiesbaden, Germany) for determination of β-hydroxybutyrate (BHB) concentrations in bovine blood were evaluated by comparing the measurements with a laboratory reference. The BHB concentration was determined with the FSP-Neo device in 720 capillary blood samples from 3 different sampling sites (left, right ear, and repeated measurement) and in 240 samples from a coccygeal vessel. The concentration of BHB in serum harvested from the coccygeal blood samples was analyzed at the laboratory and was used as reference. The Spearman correlation coefficient (ρs) between the BHB concentrations in capillary blood measured with the handheld device and the reference test was between 0.76 and 0.81. Using capillary blood, the mean ± standard deviation BHB difference compared with the reference test was 0.20±0.47 mmol/L for all 3 sampling locations at the ears. The receiver operating characteristic analyses for the FSP-Neo device resulted in an optimized threshold for the detection of subclinical ketosis (SCK) in capillary blood of 1.3 mmol/L (left and right ear) and 1.2 mmol/L (repeated measurements). Applying these adjusted threshold sensitivities (Se) for all 3 capillary sampling sites at the ear were 100%, and specificities (Sp) ranged between 93 and 94%. Hence, we conclude that all sampling locations were suitable to identify cows suffering from SCK. The reference test compared with BHB measurements in coccygeal blood resulted in a ρs of 0.92 with a mean ± standard deviation of 0.02±0.21 mmol/L. The receiver operating characteristic analyses for the FSP-Neo device resulted in an optimized threshold for the detection of SCK in coccygeal blood of 1.1 mmol/L, with a corresponding Se and Sp of 100 and 95%, respectively. Because capillary blood is easily achievable from an ear, particularly if animals are fixed in headlocks for routine checkups, this technique is considered as an additional minimally invasive method for the identification of dairy cows suffering from HYK. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Comment on “Rapid visual detection of blood cyanide” by C. Männel-Croisé and F. Zelder, Analytical Methods, 2012, 4, 2632

    PubMed Central

    Kadjo, Akinde F.; Boss, Gerry R

    2015-01-01

    Cyanide poisoning from Inhaled HCN is all too common in victims of smoke inhalation in fires. While the toxic effects arise primarily from its inhibitory effects on cytochrome c oxidase, the majority of the cyanide binds to methemoglobin (metHb) in the blood. It can be considered as the detoxification mechanism: one of the antidotes used earlier was nitrite which primarily works by converting hemoglobin to metHb (normally present to the extent of ~1% of the total hemoglobin). Vitamin B12 (hydroxocobalamin) and related analogs have long been known to have high affinity for cyanide and has been used as antidotes – the binding of cyanide to many compounds in this general family also results in a significant change in color that can be used for analytical purposes. Männel Croisé and Zelder (Anal. Methods, 2012, 4, 2632) have advocated direct addition of a related compound to blood samples and isolating the colored measurand on a solid phase extraction cartridge. While they demonstrated attractive rapid measurement of cyanide in spiked blood samples, we believe that this is not a practically usable procedure regardless of the exact chromogenic reagent used. Cyanide bound to metHb dissociates too slowly for a 1 min reaction to work as suggested – we believe for reasons unknown (eg., metHb levels in their blood samples unusually low), cyanide added to their blood samples did not (have time to) bind to metHb and these samples may not resemble real situations where significant amount of the cyanide will be bound to metHb. PMID:26640525

  16. Rapid Diagnosis of Staphylococcal Catheter-Related Bacteraemia in Direct Blood Samples by Real-Time PCR

    PubMed Central

    Soto, Marcelo; Sampietro-Colom, Laura; Soriano, Alex; Alvarez-Martínez, Míriam José; Almela, Manel; Marco, Francesc; Arjona, Ruth; Cobos-Trigueros, Nazaret; Morata, Laura; Mensa, José; Martínez, José Antonio; Mira, Aurea

    2016-01-01

    Catheter-related bacteremia (CRB) is an important cause of morbidity and mortality among hospitalized patients, being staphylococci the main etiologic agents. The objective of this study was to assess the use of a PCR-based assay for detection of staphylococci directly from blood obtained through the catheter to diagnose CRB caused by these microorganisms and to perform a cost-effectiveness analysis. A total of 92 patients with suspected CRB were included in the study. Samples were obtained through the catheter. Paired blood cultures were processed by standard culture methods and 4 ml blood samples were processed by GeneXpert-MRSA assay for the detection of methicillin-susceptible (MSSA) or methicillin-resistant (MRSA) Staphylococcus aureus, and methicillin-resistant coagulase-negative staphylococci (MR-CoNS). Sixteen CRB caused by staphylococci were diagnosed among 92 suspected patients. GeneXpert detected 14 out of 16 cases (87.5%), including 4 MSSA and 10 MR-CoNS in approximately 1 hour after specimen receipt. The sensitivity and specificity of GeneXpert were 87.5% (CI 95%: 60.4–97.8) and 92.1% (CI 95%: 83–96.7), respectively, compared with standard culture methods. The sensitivity of GeneXpert for S. aureus was 100%. Regarding a cost-effectiveness analysis, the incremental cost of using GeneXpert was of 31.1€ per patient while the incremental cost-effectiveness ratio of GeneXpert compared with blood culture alones was about 180€ per life year gained. In conclusion, GeneXpert can be used directly with blood samples obtained through infected catheters to detect S. aureus and MR-CoNS in approximately 1h after sampling. In addition, it is cost-effective especially in areas with high prevalence of staphylococcal CRB. PMID:27571200

  17. Mercury in the blood and eggs of American kestrels fed methylmercury chloride

    USGS Publications Warehouse

    French, J.B.; Bennett, R.S.; Rossmann, R.

    2010-01-01

    American kestrels (Falco sparverius) were fed diets containing methylmercury chloride (MeHg) at 0, 0.6, 1.7, 2.8, 3.9, or 5.0 ??g/g (dry wt) starting approximately eight weeks before the onset of egg laying. Dietary treatment was terminated after 12 to 14 weeks, and unhatched eggs were collected for Hg analysis. Blood samples were collected after four weeks of treatment and the termination of the study (i.e., 12-14 weeks of treatment). Clutch size decreased at dietary concentrations above 2.8 ??g/g. The average total mercury concentration in clutches of eggs and in the second egg laid (i.e., egg B) increased linearly with dietary concentration. Mercury concentrations in egg B were approximately 25% lower than in the first egg laid and similar in concentration to the third egg laid. Mercury concentrations in whole blood and plasma also increased linearly with dietary concentration. Total Hg concentrations in June blood samples were lower than those in April, despite 8 to 10 weeks of additional dietary exposure to MeHg in the diet. This is likely because of excretion of Hg into growing flight feathers beginning shortly after the start of egg production. The strongest relationships between Hg concentrations in blood and eggs occurred when we used blood samples collected in April before egg laying and feather molt. ?? 2010 SETAC.

  18. Comparative study of two protocols for quantitative image-analysis of serotonin transporter clustering in lymphocytes, a putative biomarker of therapeutic efficacy in major depression.

    PubMed

    Romay-Tallon, Raquel; Rivera-Baltanas, Tania; Allen, Josh; Olivares, Jose M; Kalynchuk, Lisa E; Caruncho, Hector J

    2017-01-01

    The pattern of serotonin transporter clustering on the plasma membrane of lymphocytes extracted from human whole blood samples has been identified as a putative biomarker of therapeutic efficacy in major depression. Here we evaluated the possibility of performing a similar analysis using blood smears obtained from rats, and from control human subjects and depression patients. We hypothesized that we could optimize a protocol to make the analysis of serotonin protein clustering in blood smears comparable to the analysis of serotonin protein clustering using isolated lymphocytes. Our data indicate that blood smears require a longer fixation time and longer times of incubation with primary and secondary antibodies. In addition, one needs to optimize the image analysis settings for the analysis of smears. When these steps are followed, the quantitative analysis of both the number and size of serotonin transporter clusters on the plasma membrane of lymphocytes is similar using both blood smears and isolated lymphocytes. The development of this novel protocol will greatly facilitate the collection of appropriate samples by eliminating the necessity and cost of specialized personnel for drawing blood samples, and by being a less invasive procedure. Therefore, this protocol will help us advance the validation of membrane protein clustering in lymphocytes as a biomarker of therapeutic efficacy in major depression, and bring it closer to its clinical application.

  19. Diseases and parasites in wolves of the Riding Mountain National Park region, Manitoba, Canada.

    PubMed

    Stronen, Astrid V; Sallows, Tim; Forbes, Graham J; Wagner, Brent; Paquet, Paul C

    2011-01-01

    We examined wolf (Canis lupus) blood and fecal samples from the Riding Mountain National Park (RMNP) region of Manitoba, Canada. In 601 fecal samples collected during two study periods in RMNP and the Duck Mountain Provincial Park and Forest (DMPPF) we found gastrointestinal helminth eggs from Alaria sp. (15.5%), Capillaria sp. (1.0%), taeniid tapeworms (30.8%), Toxascaris sp. (1.7%), Toxocara sp. (0.2%), Trichuris sp. (2.2%), and Moniezia sp. (0.5%). In addition, we found Demodex sp. (0.2%) and the protozoal cysts/oocysts of Sarcocystis sp. (37.3%), Cryptosporidium sp. (1.2%), coccidia (Isospora sp. or Eimeria sp.) (1.7%), and Giardia sp. (29.5%). No fecal shedding of canine parvovirus (CPV, n=387) was detected. All 18 blood samples collected in RMNP showed CPV exposure and eight of 18 blood samples indicated canine distemper virus (CDV) exposure. One wolf died from CDV. Our results are consistent with previous findings on pathogens affecting wolves and with high Giardia sp. prevalence in wolves inhabiting agricultural regions.

  20. A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

    PubMed

    Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal

    2015-01-01

    Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.

  1. BloodSpot: a database of gene expression profiles and transcriptional programs for healthy and malignant haematopoiesis

    PubMed Central

    Bagger, Frederik Otzen; Sasivarevic, Damir; Sohi, Sina Hadi; Laursen, Linea Gøricke; Pundhir, Sachin; Sønderby, Casper Kaae; Winther, Ole; Rapin, Nicolas; Porse, Bo T.

    2016-01-01

    Research on human and murine haematopoiesis has resulted in a vast number of gene-expression data sets that can potentially answer questions regarding normal and aberrant blood formation. To researchers and clinicians with limited bioinformatics experience, these data have remained available, yet largely inaccessible. Current databases provide information about gene-expression but fail to answer key questions regarding co-regulation, genetic programs or effect on patient survival. To address these shortcomings, we present BloodSpot (www.bloodspot.eu), which includes and greatly extends our previously released database HemaExplorer, a database of gene expression profiles from FACS sorted healthy and malignant haematopoietic cells. A revised interactive interface simultaneously provides a plot of gene expression along with a Kaplan–Meier analysis and a hierarchical tree depicting the relationship between different cell types in the database. The database now includes 23 high-quality curated data sets relevant to normal and malignant blood formation and, in addition, we have assembled and built a unique integrated data set, BloodPool. Bloodpool contains more than 2000 samples assembled from six independent studies on acute myeloid leukemia. Furthermore, we have devised a robust sample integration procedure that allows for sensitive comparison of user-supplied patient samples in a well-defined haematopoietic cellular space. PMID:26507857

  2. Stress-induced suppression of testosterone secretion in male alligators.

    PubMed

    Lance, V A; Elsey, R M

    1986-08-01

    In order to test the effect of acute stress on gonadal hormone secretion in reptiles, six mature male alligators were captured, and a blood sample was taken within 5 min of capture. Additional blood samples were taken at timed intervals for up to 41 hr, and plasma testosterone and corticosterone were measured by radioimmunoassay. Plasma testosterone declined to 50% of the initial value by 4 hr and dropped to less than 10% of initial by 24 hr. Plasma corticosterone increased during the first 12 hr, declined at 24 hr, and rose again at 40 hr. Blood samples from male alligators collected in North and South Carolina, south Florida, and in south Louisiana in two consecutive breeding seasons were also assayed for testosterone and corticosterone. In these populations there were significant differences in mean plasma testosterone and corticosterone levels. Elevated corticosterone levels were consistently seen in alligators caught in traps and from which a blood sample was taken several hours later. Plasma testosterone, although consistently lower in trapped alligators, did not show a negative correlation with plasma corticosterone. Farm-reared alligators bled once, released, and bled again at 24 hr also showed a highly significant suppression of testosterone secretion. These results demonstrate that stress has a rapid and dramatic effect on testicular steroid secretion in both farm-reared and wild alligators.

  3. Sensitivity and specificity of a nested polymerase chain reaction for detection of lentivirus infection in lions (Panthera leo).

    PubMed

    Adams, Hayley; van Vuuren, Moritz; Kania, Stephen; Bosman, Anna-Mari; Keet, Dewald; New, John; Kennedy, Melissa

    2010-12-01

    Feline immunodeficiency virus (FIV) is a lentivirus in the Retroviridae family that causes lifelong infection in domestic cats. The lentivirus of African lions (Panthera leo), referred to as FIVple, is endemic in certain lion populations in eastern and southern Africa. Lentivirus infection leads to immunologic dysfunction and immunosuppressive disease in domestic cats; however, little is known about the pathogenic effects of infection in lions, nor about the epidemiologic impact on free-ranging and captive populations. Whole blood and serum samples were collected opportunistically from free-ranging lions in Kruger National Park, Republic of South Africa (RSA). Whole blood and serum samples were also collected from captive wild lions in the RSA. A nested polymerase chain reaction (PCR) assay for detection of FIV was performed on all whole blood samples. In addition, serum samples were tested for cross-reactive antibodies to domestic feline lentivirus antigens and puma lentivirus synthetic envelope peptide antigen. The PCR assay successfully amplified the lion lentivirus from African lions. The relative sensitivity and relative specificity were 79% and 100%, respectively, and the positive and negative predictive values were 100% and 67%, respectively. This research represents the first study to compare genetic material with antibody-based methods of lentivirus detection on lions in RSA. Using PCR as an additional diagnostic test for FIV in lions will increase screening sensitivity and will allow viral characterization among circulating isolates and monitoring of changes in the viral epidemiology within geographic regions and populations over time.

  4. Blood-Based Analyses of Cancer: Circulating Tumor Cells and Circulating Tumor DNA

    PubMed Central

    Haber, Daniel A.; Velculescu, Victor E.

    2015-01-01

    The ability to study nonhematologic cancers through noninvasive sampling of blood is one of the most exciting and rapidly advancing fields in cancer diagnostics. This has been driven both by major technologic advances, including the isolation of intact cancer cells and the analysis of cancer cell–derived DNA from blood samples, and by the increasing application of molecularly driven therapeutics, which rely on such accurate and timely measurements of critical biomarkers. Moreover, the dramatic efficacy of these potent cancer therapies drives the selection for additional genetic changes as tumors acquire drug resistance, necessitating repeated sampling of cancer cells to adjust therapy in response to tumor evolution. Together, these advanced noninvasive diagnostic capabilities and their applications in guiding precision cancer therapies are poised to change the ways in which we select and monitor cancer treatments. Significance Recent advances in technologies to analyze circulating tumor cells and circulating tumor DNA are setting the stage for real-time, noninvasive monitoring of cancer and providing novel insights into cancer evolution, invasion, and metastasis. PMID:24801577

  5. Clinical Usefulness of Real-Time Polymerase Chain Reaction for the Diagnosis of Vibrio vulnificus Infection Using Skin and Soft Tissues.

    PubMed

    Lee, Jun-Young; Kim, Seok Won; Kim, Dong-Min; Yun, Na Ra; Kim, Choon-Mee; Lee, Sang-Hong

    2017-08-01

    Vibrio vulnificus is a halophilic gram-negative bacillus isolated in seawater, fish, and shellfish. Infection by V. vulnificus is the most severe food-borne infection reported in the United States of America. Here, we aimed to examine the clinical usefulness of polymerase chain reaction (PCR) using tissue specimens other than blood samples as a diagnostic tool for V. vulnificus infection. A retrospective study was conducted with patients who underwent real-time PCR of toxR in both blood and skin tissues, including serum, bullae, swab, and operation room specimens, between 2006 and 2009. The median V. vulnificus DNA load of 14 patients in real-time PCR analysis of serum at the time of admission was 638.5 copies/mL blood, which was within the interquartile range (IQR: 37-3,225). In contrast, the median value by real-time PCR using the first tissue specimen at the time of admission was 16,650 copies/mL tissue fluid (IQR: 4,419-832,500). This difference was statistically significant ( P = 0.022). DNA copy numbers in tissues were less affected by short-term antibiotic administration than that in blood samples, and antibiotic administration increased the DNA copy number in some patients. We found, for the first time, that DNA copy numbers in tissues of patients infected by V. vulnificus were higher than those in blood samples. Additionally, skin lesions were more useful than blood samples as specimens for PCR analysis in patients administered antibiotics for V. vulnificus infection before admission.

  6. Analytical Validation of Quantitative Real-Time PCR Methods for Quantification of Trypanosoma cruzi DNA in Blood Samples from Chagas Disease Patients

    PubMed Central

    Ramírez, Juan Carlos; Cura, Carolina Inés; Moreira, Otacilio da Cruz; Lages-Silva, Eliane; Juiz, Natalia; Velázquez, Elsa; Ramírez, Juan David; Alberti, Anahí; Pavia, Paula; Flores-Chávez, María Delmans; Muñoz-Calderón, Arturo; Pérez-Morales, Deyanira; Santalla, José; Guedes, Paulo Marcos da Matta; Peneau, Julie; Marcet, Paula; Padilla, Carlos; Cruz-Robles, David; Valencia, Edward; Crisante, Gladys Elena; Greif, Gonzalo; Zulantay, Inés; Costales, Jaime Alfredo; Alvarez-Martínez, Miriam; Martínez, Norma Edith; Villarroel, Rodrigo; Villarroel, Sandro; Sánchez, Zunilda; Bisio, Margarita; Parrado, Rudy; Galvão, Lúcia Maria da Cunha; da Câmara, Antonia Cláudia Jácome; Espinoza, Bertha; de Noya, Belkisyole Alarcón; Puerta, Concepción; Riarte, Adelina; Diosque, Patricio; Sosa-Estani, Sergio; Guhl, Felipe; Ribeiro, Isabela; Aznar, Christine; Britto, Constança; Yadón, Zaida Estela; Schijman, Alejandro G.

    2015-01-01

    An international study was performed by 26 experienced PCR laboratories from 14 countries to assess the performance of duplex quantitative real-time PCR (qPCR) strategies on the basis of TaqMan probes for detection and quantification of parasitic loads in peripheral blood samples from Chagas disease patients. Two methods were studied: Satellite DNA (SatDNA) qPCR and kinetoplastid DNA (kDNA) qPCR. Both methods included an internal amplification control. Reportable range, analytical sensitivity, limits of detection and quantification, and precision were estimated according to international guidelines. In addition, inclusivity and exclusivity were estimated with DNA from stocks representing the different Trypanosoma cruzi discrete typing units and Trypanosoma rangeli and Leishmania spp. Both methods were challenged against 156 blood samples provided by the participant laboratories, including samples from acute and chronic patients with varied clinical findings, infected by oral route or vectorial transmission. kDNA qPCR showed better analytical sensitivity than SatDNA qPCR with limits of detection of 0.23 and 0.70 parasite equivalents/mL, respectively. Analyses of clinical samples revealed a high concordance in terms of sensitivity and parasitic loads determined by both SatDNA and kDNA qPCRs. This effort is a major step toward international validation of qPCR methods for the quantification of T. cruzi DNA in human blood samples, aiming to provide an accurate surrogate biomarker for diagnosis and treatment monitoring for patients with Chagas disease. PMID:26320872

  7. Development and performance test of an online blood sampling system for determination of the arterial input function in rats.

    PubMed

    Roehrbacher, Friedrich; Bankstahl, Jens P; Bankstahl, Marion; Wanek, Thomas; Stanek, Johann; Sauberer, Michael; Muellauer, Julia; Schroettner, Thales; Langer, Oliver; Kuntner, Claudia

    2015-12-01

    For positron emission tomography (PET) kinetic modelling, an accurate determination of the arterial input function is required. In this study, a blood sampling system was developed and tested using different radiotracers in rats. The detector consists of pairs of lutetium yttrium oxyorthosilicate (LYSO) detectors, photomultiplier tubes and lead shield assembled within a steel casing working in coincidence mode. Rats were cannulated with microtubes in the femoral artery and vein for arterial blood sampling as well as administration of the PET tracers. Connected PTFE microtubes were centred between the LYSO crystals using a special holder. To enhance sensitivity, three layers with two coils were used. A flexible tube pump was used to ensure a constant blood flow. Performance of the detector was assessed with [(18)F]fludeoxyglucose (FDG), [(18)F]ciprofloxacin, (R)-[(11)C]verapamil, [(11)C]tariquidar, [(11)C]mephobarbital and [(11)C]MC113. Obtained input function curves were compared with manual samples drawn every 5 s during the first 3 min and further on at 5, 10, 20, 30, 40, 50 and 60 min after radiotracer injection. After manual sampling, an arterio/venous shunt was established. Shape and area-under-the-curve (AUC; Bq/μl*h) of the input functions were evaluated. The developed detector system provided an absolute sensitivity of 6.5%. Maximum peak values agreed well between manual samples and the detector with a mean difference of -0.4% ± 7.0% (max 12.0%, min -9.9%). AUC values also exhibited an excellent correlation (R = 0.996) between manual sampling and detector measurements with a mean difference of 9.3% ± 9.7% (max 24.1%, min -3.2%). The system was able to measure peak blood activity concentration levels of 110 to 2,000 Bq/μl which corresponds to injected activities from 5.5 to 100 MBq depending on the used radiotracer, applied volume and weight of the animal. This study demonstrates that the developed blood sampling system can be used for in vivo small animal PET studies in rats in a reliable way. The usage of the systems enhances the accuracy of the input curve as handling of small blood samples especially with low activity (as for C-11) is prone to measurement errors. Additionally, the radiation dose of the experimenters can be reduced, as it is not required anymore to continuously draw samples where the personal is in close contact to the radioactive animals and blood.

  8. Blood and Plasma Biochemistry Reference Intervals for Wild Juvenile American Alligators ( Alligator mississippiensis ).

    PubMed

    Hamilton, Matthew T; Kupar, Caitlin A; Kelley, Meghan D; Finger, John W; Tuberville, Tracey D

    2016-07-01

    : American alligators ( Alligator mississippiensis ) are one of the most studied crocodilian species in the world, yet blood and plasma biochemistry information is limited for juvenile alligators in their northern range, where individuals may be exposed to extreme abiotic and biotic stressors. We collected blood samples over a 2-yr period from 37 juvenile alligators in May, June, and July to establish reference intervals for 22 blood and plasma analytes. We observed no effect of either sex or blood collection time on any analyte investigated. However, our results indicate a significant correlation between a calculated body condition index and aspartate aminotransferase and creatine kinase. Glucose, total protein, and potassium varied significantly between sampling sessions. In addition, glucose and potassium were highly correlated between the two point-of-care devices used, although they were significantly lower with the i-STAT 1 CG8+ cartridge than with the Vetscan VS2 Avian/Reptile Rotor. The reference intervals presented herein should provide baseline data for evaluating wild juvenile alligators in the northern portion of their range.

  9. Detection of Theileria annulata in blood samples of carrier cattle by PCR.

    PubMed Central

    d'Oliveira, C; van der Weide, M; Habela, M A; Jacquiet, P; Jongejan, F

    1995-01-01

    We report the detection of Theileria annulata, the causative agent of tropical theileriosis, by PCR in blood samples obtained from carrier cattle. The assay employs primers specific for the gene encoding the 30-kDa major merozoite surface antigen of T. annulata. A 721-bp fragment was amplified from blood samples taken monthly from calves experimentally infected with one of four different stocks of T. annulata originating in either Mauritania, Portugal, Spain, or Turkey. At the end of the experiment, five animals carried the infection for 12 months and two animals remained infected for 15 months. DNAs from six other Theileria species, T. parva, T. mutans, T. sergenti, T. buffeli, T. velifera, and T. taurotragi, were not amplified. Moreover, DNAs from four other hemoparasites (Anaplasma centrale, Anaplasma marginale, Babesia bovis, and Babesia bigemina) were also not amplified. As a control, primers derived from the small subunit rRNA gene of Theileria spp. amplified a 1.1-kb DNA fragment from all Theileria species examined but not from the other four hemoparasites. As few as two to three parasites per microliter of infected blood in a 50-microliters sample volume were detected by Southern or microplate hybridization with a T. annulata-specific cDNA probe. In addition, 92 field samples obtained from cattle in Spain were tested; 22% were positive in blood smears, 40% were positive by immunofluorescent antibody test, and 75% were positive for T. annulata by PCR. The method provides a useful diagnostic tool for detecting T. annulata carrier cattle. PMID:8567902

  10. An on-spot internal standard addition approach for accurately determining colistin A and colistin B in dried blood spots using ultra high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung

    2017-10-25

    Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were < 2min. The relative standard deviations of within-run and between-run precisions for peak area ratios were all < 17.3%. Accuracies were 91.5-111.2% for lower limit of quantification, low, medium, and high QC samples. The stability of the easily hydrolyzed prodrug, colistin methanesulfonate, was investigated in DBSs. Less than 4% of the prodrug was found to be hydrolyzed in DBSs at room temperature after 48h. The developed method applied an on-spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Lidocaine Concentration in Oral Tissue by the Addition of Epinephrine.

    PubMed

    Tanaka, Eri; Yoshida, Kenji; Kawaai, Hiroyoshi; Yamazaki, Shinya

    2016-01-01

    The vasoconstrictive effect due to the addition of epinephrine to local anesthetic has been clearly shown by measuring blood-flow volume or blood anesthetic concentration in oral mucosal tissue. However, there are no reports on the measurement of anesthetic concentration using samples directly taken from the jawbone and oral mucosal tissue. Consequently, in this study, the effect of lidocaine concentration in the jawbone and oral mucosal tissue by the addition of epinephrine to the local anesthetic lidocaine was considered by quantitatively measuring lidocaine concentration within the tissue. Japanese white male rabbits (n = 96) were used as test animals. General anesthesia was induced by sevoflurane and oxygen, and then cannulation to the femoral artery was performed while arterial pressure was constantly recorded. Infiltration anesthesia was achieved by 0.5 mL of 2% lidocaine containing 1 : 80,000 epinephrine in the upper jawbone (E(+)) and 0.5 mL of 2% of epinephrine additive-free lidocaine (E(0)) under the periosteum. At specified time increments (10, 20, 30, 40, 50, and 60 minutes), samples from the jawbone, oral mucosa, and blood were collected, and lidocaine concentration was directly measured by high-performance liquid chromatography. No significant differences in the change in blood pressure were observed either in E(+) or E(0). In both E(+) and E(0) groups, the serum lidocaine concentration peaked 10 minutes after local anesthesia and decreased thereafter. At all time increments, serum lidocaine concentration in E(+) was significantly lower than that in E(0). There were no significant differences in measured lidocaine concentration between jawbone and mucosa within either the E(+) or the E(0) groups at all time points, although the E(0) group had significantly lower jawbone and mucosa concentrations than the E(+) group at all time points when comparing the 2 groups to each other. Addition of epinephrine to the local anesthetic inhibited systemic absorption of local anesthetic into the blood such that a high concentration could be maintained in the tissue. Epinephrine-induced vasoconstrictive effect was observed not only in the oral mucosa but also in the jawbone.

  12. Blood characterization using UV/vis spectroscopy

    NASA Astrophysics Data System (ADS)

    Mattley, Yvette D.; Mitrani-Gold, F.; Orton, S.; Bacon, Christina P.; Leparc, German F.; Bayona, M.; Potter, Robert L.; Garcia-Rubio, Luis H.

    1995-05-01

    The current methods used for typing blood involve an agglutination reaction which results from the association of specific antibodies with antigens present on the erythrocyte cell surface. While this method is effective, it requires involved laboratory procedures to detect the cell surface antigens. As an alternative technique, uv/vis spectroscopy has been investigated as a novel way to characterize and differentiate the blood types. Typing with this technique is based on spectral differences which appear throughout portions of both the ultraviolet and visible range. The origin of these spectral differences is unknown and presently under investigation. They may be due to intrinsic absorption differences at the molecular level, and/or they may be due to scattering differences brought about by either subtle variation in cell surface characteristics, cell shape or state of aggregation. As the background optical density in these samples is identified and accounted for, the spectral differences become more defined. This work and the continuation of this project will be included in a general database encompassing a wide range of blood samples. In addition, long term goals involve the investigation of diseased blood with the potential of providing a more rapid diagnosis for blood borne pathogens.

  13. Short-Term Storage of Platelet-Rich Plasma at Room Temperature Does Not Affect Growth Factor or Catabolic Cytokine Concentration.

    PubMed

    Wilson, Brooke H; Cole, Brian J; Goodale, Margaret B; Fortier, Lisa A

    2018-04-01

    The aim of this study was to provide clinical recommendations about the use of platelet-rich plasma (PRP) that was subjected to short-term storage at room temperature. We determined bioactive growth factor and cytokine concentrations as indicators of platelet and white blood cell degranulation in blood and PRP. Additionally, this study sought to validate the use of manual, direct smear analysis as an alternative to automated methods for platelet quantification in PRP. Blood was used to generate low-leukocyte PRP (Llo PRP) or high-leukocyte PRP (Lhi PRP). Blood was either processed immediately or kept at room temperature for 2 or 4 hours prior to generation of PRP, which was then held at room temperature for 0, 1, 2, or 4 hours. Subsequently, bioactive transforming growth factor beta-1 and matrix metalloproteinase-9 were measured by ELISA (enzyme-linked immunosorbent assay). Manual and automated platelet counts were performed on all blood and PRP samples. There were no differences in growth factor or cytokine concentration when blood or Llo PRP or Lhi PRP was retained at room temperature for up to 4 hours. Manual, direct smear analysis for platelet quantification was not different from the use of automated machine counting for PRP samples, but in the starting blood samples, manual platelet counts were significantly higher than those generated using automated technology. When there is a delay of up to 4 hours in the generation of PRP from blood or in the application of PRP to the patient, bioactive growth factor and cytokine concentrations remain stable in both blood and PRP. A manual direct counting method is a simple, cost-effective, and valid method to measure the contents of the PRP product being delivered to the patient.

  14. Cryopreservation of umbilical cord blood with a novel freezing solution that mimics intracellular ionic composition.

    PubMed

    Nicoud, Ian B; Clarke, Dominic M; Taber, Greta; Stolowski, Kristin M; Roberge, Sarah E; Song, Melissa K; Mathew, Aby J; Reems, Jo-Anna

    2012-09-01

    Cryopreservation protocols have remained relatively unchanged since the first umbilical cord blood banking program was established. This study evaluated the preservation efficacy of a novel intracellular-like cryopreservation solution (CryoStor, BioLife Solutions, Inc.), the rate of addition of two cryopreservation solutions to cord blood units (CBUs), and reduced final dimethyl sulfoxide (DMSO) concentration of 5%. Split-sample CBUs were cryopreserved with either an in-house 20% DMSO-based cryopreservation solution or CryoStor CS10 at a rate of 1 mL/min (n = 10; i.e., slow addition) or as a bolus injection (n = 6; i.e., fast addition). Infrared images of exothermic effects of the cryopreservation solutions were monitored relative to the rate of addition. Prefreeze and postthaw colony-forming unit assays, total nucleated cells, and CD34+ cell counts were compared. Maximum temperature excursions observed were less than 6°C, regardless of the rate of solution addition. Fast addition resulted in peak excursions approximately twice that of slow addition but the magnitude and duration were minimal and transient. Slow addition of CryoStor CS10 (i.e., final concentration ≤ 5% DMSO) resulted in significantly better postthaw CD34+ cell recoveries; no other metrics were significantly different. Fast addition of CryoStor resulted in similar postthaw metrics compared to slow addition of the in-house solution. Slow and fast addition of cryopreservation solutions result in mean temperature changes of approximately 3.3 to 4.45°C. Postthaw recoveries with CryoStor were equivalent to or slightly better than with the in-house cryopreservation solution. CryoStor also provides several advantages including reduced processing time, formulation consistency, and reduced DMSO in the frozen product (≤ 5%). © 2012 American Association of Blood Banks.

  15. Personalized monitoring of therapeutic salicylic acid in dried blood spots using a three-layer setup and desorption electrospray ionization mass spectrometry.

    PubMed

    Siebenhaar, Markus; Küllmer, Kai; Fernandes, Nuno Miguel de Barros; Hüllen, Volker; Hopf, Carsten

    2015-09-01

    Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.

  16. Method for extending the useful shelf-life of refrigerated red blood cells by flushing with inert gas

    DOEpatents

    Bitensky, Mark W.; Yoshida, Tatsuro

    1997-01-01

    Method using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4.degree. C. storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4.degree. C. for prolonged periods of time is achieved by removing oxygen therefrom at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate.

  17. [Investigation of West Nile virus RNA in blood donors by real-time RT-PCR].

    PubMed

    Sahiner, Fatih; Avcı, Ismail Yaşar; Bedir, Orhan; Koru, Ozgür; Sener, Kenan; Yapar, Mehmet; Kubar, Ayhan

    2012-07-01

    West Nile virus (WNV), a member of Flaviviridae family, is an enveloped, icosahedral symmetric RNA virus. Primary reservoir hosts of WNV are birds, but the virus can cause various infections in humans and other mammals. The most common and natural transmission way of WNV infections is mosquito bites, however, humans can be infected by different routes. The most important non-mosquito transmission route is contaminated blood and blood products. In this study, we aimed to investigate the risk of WNV transmission through blood and blood products in Ankara, Turkey. The presence of WNV RNA was investigated by in house real-time reverse transcriptase-polymerase chain reaction (RT-PCR) in serum samples obtained from 729 healthy blood donors (mean age: 27.7 years; 711 were male), regardless of the donor's seropositivity status since the virus can be transmitted at the early stages of infection when seroconversion has not yet developed. Serum samples were collected in August-September 2009, the period when these infections are more frequent due to mosquito activity. The vast majority of donors (n= 702, 96.3%) have been inhabiting in Ankara and 569 (78%) of donors have had risk factors for arboviral infections (e.g. outdoor activity, mosquito and tick bites). WNV RNA was not detected by real-time RT-PCR analysis in any serum sample included in this study. According to the results of our study, it can be said that the risk of WNV transmission through blood and blood products is low in Ankara. However, WNV seropositivity was detected within the range of 0.56 to 2.4% among blood donors in previous studies and probable and confirmed WNV infections have been reported in our region. In addition, WNV outbreaks have emerged in some countries neighbouring Turkey recently. Thus, the risk of WNV transmission through blood and blood products should not be ignored and blood donor questionnaires should be evaluated in detail.

  18. Cryopreservation prevents iron-initiated highly unsaturated fatty acid loss during storage of human blood on chromatography paper at -20°C.

    PubMed

    Metherel, Adam H; Stark, Ken D

    2015-03-01

    Fingertip prick whole blood collection on chromatography paper is amenable to high-throughput fatty acid (FA) profiling for large clinical and field studies. However, sample storage is problematic because highly unsaturated FAs (HUFAs) in erythrocytes rapidly degrade in samples stored at -20°C. The aim of the current study was to determine the mechanism of HUFA degradation and to develop prevention protocols. Free fatty acid (FFA) standards and whole blood reference material from a single participant were used to examine sample storage at -20°C for up to 90 d in triplicate. Iron chelation with deferoxamine (0-5000 μg), antioxidant protection with butylated hydroxytoluene (50 μg), cryopreservation with glycerol, and blood drying were examined using whole blood on chromatography strips. Biological replicate blood samples from additional participants (n = 6) with a range of ω-3 (n-3) HUFA concentrations were similarly assessed. FFAs were relatively stable when stored on chromatography strips at -20°C. Glycerol treatment prevented HUFA degradation in whole blood reference material for 30 d (45 ± 0.4 to 46.8 ± 0.1, means ± SDs) compared to untreated saline controls (45.9 ± 1.0 to 6.8 ± 0.2). Pretreatment of paper for blood spots with deferoxamine and drying blood before storage slowed, but not entirely prevented, HUFA degradation over 30 d to 22% and 19% below baseline, respectively, compared to 86-92% in the controls. Protection against HUFA degradation with blood drying and glycerol treatment was confirmed in the biological replicate study and confirmed by prevention of cell lysis. HUFA degradation during storage at -20°C appears to be due to hemolysis and subsequent iron-initiated peroxidation. This degradation may be prevented by glycerol, iron chelation, and/or dried blood spotting. A more thorough understanding of methods to prevent degradation during storage is critical with increasing use of FA profiling in large clinical studies. © 2015 American Society for Nutrition.

  19. Detection of Babesia canis vogeli and Hepatozoon canis in canine blood by a single-tube real-time fluorescence resonance energy transfer polymerase chain reaction assay and melting curve analysis.

    PubMed

    Kongklieng, Amornmas; Intapan, Pewpan M; Boonmars, Thidarut; Thanchomnang, Tongjit; Janwan, Penchom; Sanpool, Oranuch; Lulitanond, Viraphong; Taweethavonsawat, Piyanan; Chungpivat, Sudchit; Maleewong, Wanchai

    2015-03-01

    A real-time fluorescence resonance energy transfer polymerase chain reaction (qFRET PCR) coupled with melting curve analysis was developed for detection of Babesia canis vogeli and Hepatozoon canis infections in canine blood samples in a single tube assay. The target of the assay was a region within the 18S ribosomal RNA gene amplified in either species by a single pair of primers. Following amplification from the DNA of infected dog blood, a fluorescence melting curve analysis was done. The 2 species, B. canis vogeli and H. canis, could be detected and differentiated in infected dog blood samples (n = 37) with high sensitivity (100%). The detection limit for B. canis vogeli was 15 copies of a positive control plasmid, and for H. canis, it was 150 copies of a positive control plasmid. The assay could simultaneously distinguish the DNA of both parasites from the DNA of controls. Blood samples from 5 noninfected dogs were negative, indicating high specificity. Several samples can be run at the same time. The assay can reduce misdiagnosis and the time associated with microscopic examination, and is not prone to the carryover contamination associated with the agarose gel electrophoresis step of conventional PCR. In addition, this qFRET PCR method would be useful to accurately determine the range of endemic areas or to discover those areas where the 2 parasites co-circulate. © 2015 The Author(s).

  20. The effects of transport by car on coagulation tests.

    PubMed

    Ergin, Merve; Erdogan, Serpil; Akturk, Onur; Erel, Ozcan

    2017-10-26

    This research investigated the effects of the transport of blood samples between centers/laboratories by car on coagulation tests. Five tubes of blood samples were taken from 20 healthy volunteers. The samples consisted of a baseline (control) group, centrifuged and noncentrifuged transported samples; centrifuged and noncentrifuged untransported samples. The groups of centrifuged and noncentrifuged samples were transported by car for 2 h. The centrifuged and noncentrifuged untransported samples were incubated in the laboratory until the transported samples arrived. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests were conducted for all samples. Significant differences between the baseline group and the centrifuged and noncentrifuged transported samples and the noncentrifuged untransported samples were found for APTT levels (p<0.05, for all). In addition, significant mean percentage differences in PT values were found between the baseline group and the noncentrifuged transported samples (p<0.001) and the noncentrifuged untransported samples (p=0.005). The mean level of PT in the noncentrifuged transported samples was outside the upper limit of the clinical decision level. Noncentrifuged transported samples showed clinically significant differences in PT test results that may have stemmed from mechanical agitation during transportation. Therefore, we recommend not transporting noncentrifuged specimens for PT testing by car.

  1. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl

    USGS Publications Warehouse

    Smith, Matthew M.; Schmutz, Joel A.; Apelgren, Chloe; Ramey, Andy M.

    2015-01-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n = 105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R2 = 0.694, P = 0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species.

  2. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    PubMed

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  3. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    PubMed

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  4. Evaluation of limited blood sampling population input approaches for kinetic quantification of [18F]fluorothymidine PET data.

    PubMed

    Contractor, Kaiyumars B; Kenny, Laura M; Coombes, Charles R; Turkheimer, Federico E; Aboagye, Eric O; Rosso, Lula

    2012-03-24

    Quantification of kinetic parameters of positron emission tomography (PET) imaging agents normally requires collecting arterial blood samples which is inconvenient for patients and difficult to implement in routine clinical practice. The aim of this study was to investigate whether a population-based input function (POP-IF) reliant on only a few individual discrete samples allows accurate estimates of tumour proliferation using [18F]fluorothymidine (FLT). Thirty-six historical FLT-PET data with concurrent arterial sampling were available for this study. A population average of baseline scans blood data was constructed using leave-one-out cross-validation for each scan and used in conjunction with individual blood samples. Three limited sampling protocols were investigated including, respectively, only seven (POP-IF7), five (POP-IF5) and three (POP-IF3) discrete samples of the historical dataset. Additionally, using the three-point protocol, we derived a POP-IF3M, the only input function which was not corrected for the fraction of radiolabelled metabolites present in blood. The kinetic parameter for net FLT retention at steady state, Ki, was derived using the modified Patlak plot and compared with the original full arterial set for validation. Small percentage differences in the area under the curve between all the POP-IFs and full arterial sampling IF was found over 60 min (4.2%-5.7%), while there were, as expected, larger differences in the peak position and peak height.A high correlation between Ki values calculated using the original arterial input function and all the population-derived IFs was observed (R2 = 0.85-0.98). The population-based input showed good intra-subject reproducibility of Ki values (R2 = 0.81-0.94) and good correlation (R2 = 0.60-0.85) with Ki-67. Input functions generated using these simplified protocols over scan duration of 60 min estimate net PET-FLT retention with reasonable accuracy.

  5. Assessment of the relationships among coagulopathy, hyperfibrinolysis, plasma lactate, and protein C in dogs with spontaneous hemoperitoneum.

    PubMed

    Fletcher, Daniel J; Rozanski, Elizabeth A; Brainard, Benjamin M; de Laforcade, Armelle M; Brooks, Marjory B

    2016-01-01

    To relate coagulation and fibrinolysis derangements to shock severity as reflected by plasma lactate concentrations in dogs with spontaneous hemoperitoneum (SHP) and determine the impact on transfusions. Prospective, observational, case-control study. Three veterinary teaching hospitals. Twenty-eight client-owned dogs with SHP and 28 breed- and age-matched control dogs. None. Blood samples for platelet counts, coagulation, and anticoagulant assays (prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and protein C, thromboelastography [TEG]), fibrinolysis testing (d-dimer and TEG lysis parameters with and without the addition of 50 U/mL of tissue plasminogen activator [TEG LY30 measured with the addition of 50 U/mL of tPA to the blood sample, LY3050 and TEG LY60 measured with the addition of 50 U/mL of tPA to the blood sample, LY6050 ; LY30 and LY60]), and plasma lactate as an indicator of severity of shock were collected from SHP dogs at the time of diagnosis. SHP dogs were hypocoagulable (prolonged prothrombin time and activated partial thromboplastin time, decreased TEG maximum amplitude) and hyperfibrinolytic (increased LY3050 and TEG LY6050 ) compared to controls. The severity of hypocoagulability was related to protein C activity, while the severity of hyperfibrinolysis was related to plasma lactate concentration. Among the 18 dogs discharged from the hospital, LY3050 was significantly associated with the dose of fresh frozen plasma administered, but none of the parameters were associated with the dose of red blood cells administered. Dogs with SHP have evidence of hypocoagulability, protein C deficiency, and hyperfibrinolysis. Parameters of hyperfibrinolysis were related to plasma lactate concentrations and volume of plasma transfused during hospitalization. These derangements resemble those found in people with acute coagulopathy of trauma and shock, and activation of protein C may be a common feature to both syndromes. © Veterinary Emergency and Critical Care Society 2015.

  6. Detection of lipopolysaccharides in serum using a waveguide-based optical biosensor

    NASA Astrophysics Data System (ADS)

    Noormohamed, Aneesa; Stromberg, Loreen R.; Anderson, Aaron S.; Karim, Zachary; Dighe, Priya; Kempaiah, Prakasha; Ong'echa, John M.; Perkins, Douglas J.; Doggett, Norman; McMahon, Benjamin; Mukundan, Harshini

    2017-02-01

    Direct ultra-sensitive detection of pathogen biomarkers in blood could provide a universal strategy for diagnosis of bacterial infections, which remain a leading cause of morbidity and mortality in many areas of the world. Many factors complicate diagnosis, including the presence of multiple co-infections in a given patient, and lack of infrastructure in rural settings. In some pediatric patients, such as those in areas with poor resources, an additional challenge exists with low sample volumes due to age and other health factors such as anemia and dehydration. Our team is working on developing novel diagnostic assays, with a waveguide-based biosensor platform, to rapidly and specifically identify pathogen biomarkers from small samples of serum or plasma, allowing for the timely and sensitive diagnosis of infection at the point of care. In addition to the platform, we have developed novel membrane insertion and lipoprotein capture assay methods, to capture lipidated pathogen biomarkers in aqueous blood, by virtue of their interactions with host lipoprotein carriers. Herein, we demonstrate our efforts to adapt the lipoprotein capture assay for the detection of small concentrations of pathogen-secreted lipopolysaccharides in aqueous blood, with the ultimate aim of diagnosing Gram-negative infections effectively.

  7. Differences in sampling techniques on total post-mortem tryptase.

    PubMed

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2018-05-01

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p < 0.05) between mean post-mortem tryptase by aspiration (10.87 ug/L) and by cut down (14.15 ug/L). The mean difference between the two methods was 3.28 ug/L (median, 1.4 ug/L; min, - 6.1 ug/L; max, 16.5 ug/L; 95% CI, 0.001-6.564 ug/L). Femoral total post-mortem tryptase is significantly different, albeit by a small amount, between the two sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  8. High-speed shaking of frozen blood clots for extraction of human and malaria parasite DNA.

    PubMed

    Lundblom, Klara; Macharia, Alex; Lebbad, Marianne; Mohammed, Adan; Färnert, Anna

    2011-08-08

    Frozen blood clots remaining after serum collection is an often disregarded source of host and pathogen DNA due to troublesome handling and suboptimal outcome. High-speed shaking of clot samples in a cell disruptor manufactured for homogenization of tissue and faecal specimens was evaluated for processing frozen blood clots for DNA extraction. The method was compared to two commercial clot protocols based on a chemical kit and centrifugation through a plastic sieve, followed by the same DNA extraction protocol. Blood clots with different levels of parasitaemia (1-1,000 p/μl) were prepared from parasite cultures to assess sensitivity of PCR detection. In addition, clots retrieved from serum samples collected within two epidemiological studies in Kenya (n = 630) were processed by high speed shaking and analysed by PCR for detection of malaria parasites and the human α-thalassaemia gene. High speed shaking succeeded in fully dispersing the clots and the method generated the highest DNA yield. The level of PCR detection of P. falciparum parasites and the human thalassaemia gene was the same as samples optimally collected with an anticoagulant. The commercial clot protocol and centrifugation through a sieve failed to fully dissolve the clots and resulted in lower sensitivity of PCR detection. High speed shaking was a simple and efficacious method for homogenizing frozen blood clots before DNA purification and resulted in PCR templates of high quality both from humans and malaria parasites. This novel method enables genetic studies from stored blood clots.

  9. Differences between blood donors and a population sample: implications for case-control studies.

    PubMed

    Golding, Jean; Northstone, Kate; Miller, Laura L; Davey Smith, George; Pembrey, Marcus

    2013-08-01

    Selecting appropriate controls for studies of genetic variation in case series is important. The two major candidates involve the use of blood donors or a random sample of the population. We compare and contrast the two different populations of controls for studies of genetic variation using data from parents enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC). In addition we compute different biases using a series of hypothetical assumptions. The study subjects who had been blood donors differed markedly from the general population in social, health-related, anthropometric, and personality-related variables. Using theoretical examples, we show that blood donors are a poor control group for non-genetic studies of diseases related to environmentally, behaviourally, or socially patterned exposures. However, we show that if blood donors are used as controls in genetic studies, these factors are unlikely to make a major difference in detecting true associations with relatively rare disorders (cumulative incidence through life of <10%). Nevertheless, for more common disorders, the reduction in accuracy resulting from the inclusion in any control population of individuals who have or will develop the disease in question can create a greater bias than can socially patterned factors. Information about the medical history of a control and the parents of the control (as a proxy for whether the control will develop the disease) is more important with regard to the choice of controls than whether the controls are a random population sample or blood donors.

  10. Barrier screens: a method to sample blood-fed and host-seeking exophilic mosquitoes

    PubMed Central

    2013-01-01

    Background Determining the proportion of blood meals on humans by outdoor-feeding and resting mosquitoes is challenging. This is largely due to the difficulty of finding an adequate and unbiased sample of resting, engorged mosquitoes to enable the identification of host blood meal sources. This is particularly difficult in the south-west Pacific countries of Indonesia, the Solomon Islands and Papua New Guinea where thick vegetation constitutes the primary resting sites for the exophilic mosquitoes that are the primary malaria and filariasis vectors. Methods Barrier screens of shade-cloth netting attached to bamboo poles were constructed between villages and likely areas where mosquitoes might seek blood meals or rest. Flying mosquitoes, obstructed by the barrier screens, would temporarily stop and could then be captured by aspiration at hourly intervals throughout the night. Results In the three countries where this method was evaluated, blood-fed females of Anopheles farauti, Anopheles bancroftii, Anopheles longirostris, Anopheles sundaicus, Anopheles vagus, Anopheles kochi, Anopheles annularis, Anopheles tessellatus, Culex vishnui, Culex quinquefasciatus and Mansonia spp were collected while resting on the barrier screens. In addition, female Anopheles punctulatus and Armigeres spp as well as male An. farauti, Cx. vishnui, Cx. quinquefasciatus and Aedes species were similarly captured. Conclusions Building barrier screens as temporary resting sites in areas where mosquitoes were likely to fly was an extremely time-effective method for collecting an unbiased representative sample of engorged mosquitoes for determining the human blood index. PMID:23379959

  11. Release from quiescence of CD34+ CD38- human umbilical cord blood cells reveals their potentiality to engraft adults.

    PubMed Central

    Cardoso, A A; Li, M L; Batard, P; Hatzfeld, A; Brown, E L; Levesque, J P; Sookdeo, H; Panterne, B; Sansilvestri, P; Clark, S C

    1993-01-01

    Using optimal culture conditions in which the transforming growth factor beta 1 (TGF-beta 1) inhibitory loop has been interrupted by antisense TGF-beta 1 oligonucleotides or anti-TGF-beta serum, we have compared the proliferative capacities and the abilities of the CD34+ CD38- cell populations from bone marrow and umbilical cord blood to generate early progenitors in long-term cultures. The CD34+ CD38- fraction of umbilical cord blood accounts for 4% of the CD34+ fraction compared to only 1% in bone marrow, indicating that umbilical cord blood may be relatively enriched in stem cells. We estimate that the CD34+ CD38- cells from a typical umbilical cord blood sample produce equivalent numbers of colony-forming units (CFU)-granulocyte/erythrocyte/macrophage/megakaryocyte, twice as many CFU-granulocyte/macrophage (GM) and 3 times as many burst-forming units-erythroid as the same population from an average bone marrow sample used in adult transplantation. In addition, the colonies resulting from the umbilical cord blood samples were significantly larger than those from bone marrow, indicating a greater growth potential. However, the content of later progenitors, which may be important for short-term reconstitution, was less in umbilical cord blood-derived than in bone marrow-derived cell preparations, as estimated by a 4-fold lower production of CFU-GM in long-term cultures of CD34+ CD38+ cells. This deficit is partially compensated by the higher growth capacity of the resulting CFU-GM. These studies suggest that umbilical cord blood is a suitable source of cells for adult transplantation. PMID:7690969

  12. Early changes of the anemia phenomenon in male 100-km ultramarathoners.

    PubMed

    Chiu, Yu-Hui; Lai, Jiun-I; Wang, Shih-Hao; How, Chorng-Kuang; Li, Li-Hua; Kao, Wei-Fong; Yang, Chen-Chang; Chen, Ray-Jade

    2015-02-01

    Sports anemia is a widely observed phenomenon after prolonged running. There are various factors that contribute to sports anemia, including hemodilution, exercise-induced oxidative stress, iron deficiency, gastrointestinal bleeding, hematuria, and hemolysis resulting from foot-strike and/or from compression of contracting muscles on capillaries. Until now, there has been no published report that describes the overall hematological, urinary, and fecal consequences in Asian male ultramarathoners after a 100-km (62.5-mile) ultramarathon event. A total of 25 male runners were recruited into our study. Blood was drawn 1 week before, immediately after, and then 24 hours subsequent to the race. Hematological samples were analyzed for the anemia phenomenon. Additionally, urinary and fecal samples were collected before and after the race for detection of occult blood. The blood hemoglobin and erythropoietin values of the recruited runners showed a statistically significant rise in the immediate post-race values and a rapid drop in values at 24 hours post-race. Blood concentrations of red blood cells and hematocrit were significantly lower at 24 hours post-race compared with pre-race. The white blood cell count, interleukin-6, tumor necrosis factor-alpha, high-sensitivity C-reactive protein, and ferritin all showed significant increases both immediately after and 24 hours post-race compared with pre-race hematological values. There were immediate decreases of both haptoglobin and iron, as well as an increase of total iron-binding capacity levels in post-race blood tests. For both urinary and fecal samples, there was a statistically significant difference between the pre- and post-race results in occult blood. Running a 100-km ultramarathon will induce substantial sports anemia, and oxidative stress response, hemolysis, hematuria, and gastrointestinal bleeding are typical factors that contribute to its onset. Copyright © 2014. Published by Elsevier Taiwan.

  13. Integration of targeted metabolomics and transcriptomics identifies deregulation of phosphatidylcholine metabolism in Huntington's disease peripheral blood samples.

    PubMed

    Mastrokolias, Anastasios; Pool, Rene; Mina, Eleni; Hettne, Kristina M; van Duijn, Erik; van der Mast, Roos C; van Ommen, GertJan; 't Hoen, Peter A C; Prehn, Cornelia; Adamski, Jerzy; van Roon-Mom, Willeke

    Metabolic changes have been frequently associated with Huntington's disease (HD). At the same time peripheral blood represents a minimally invasive sampling avenue with little distress to Huntington's disease patients especially when brain or other tissue samples are difficult to collect. We investigated the levels of 163 metabolites in HD patient and control serum samples in order to identify disease related changes. Additionally, we integrated the metabolomics data with our previously published next generation sequencing-based gene expression data from the same patients in order to interconnect the metabolomics changes with transcriptional alterations. This analysis was performed using targeted metabolomics and flow injection electrospray ionization tandem mass spectrometry in 133 serum samples from 97 Huntington's disease patients (29 pre-symptomatic and 68 symptomatic) and 36 controls. By comparing HD mutation carriers with controls we identified 3 metabolites significantly changed in HD (serine and threonine and one phosphatidylcholine-PC ae C36:0) and an additional 8 phosphatidylcholines (PC aa C38:6, PC aa C36:0, PC ae C38:0, PC aa C38:0, PC ae C38:6, PC ae C42:0, PC aa C36:5 and PC ae C36:0) that exhibited a significant association with disease severity. Using workflow based exploitation of pathway databases and by integrating our metabolomics data with our gene expression data from the same patients we identified 4 deregulated phosphatidylcholine metabolism related genes ( ALDH1B1 , MBOAT1 , MTRR and PLB1 ) that showed significant association with the changes in metabolite concentrations. Our results support the notion that phosphatidylcholine metabolism is deregulated in HD blood and that these metabolite alterations are associated with specific gene expression changes.

  14. Sample preparation prior to the LC-MS-based metabolomics/metabonomics of blood-derived samples.

    PubMed

    Gika, Helen; Theodoridis, Georgios

    2011-07-01

    Blood represents a very important biological fluid and has been the target of continuous and extensive research for diagnostic, or health and drug monitoring reasons. Recently, metabonomics/metabolomics have emerged as a new and promising 'omics' platform that shows potential in biomarker discovery, especially in areas such as disease diagnosis, assessment of drug efficacy or toxicity. Blood is collected in various establishments in conditions that are not standardized. Next, the samples are prepared and analyzed using different methodologies or tools. When targeted analysis of key molecules (e.g., a drug or its metabolite[s]) is the aim, enforcement of certain measures or additional analyses may correct and harmonize these discrepancies. In omics fields such as those performed by holistic analytical approaches, no such rules or tools are available. As a result, comparison or correlation of results or data fusion becomes impractical. However, it becomes evident that such obstacles should be overcome in the near future to allow for large-scale studies that involve the assaying of samples from hundreds of individuals. In this case the effect of sample handling and preparation becomes very serious, in order to avoid wasting months of work from experts and expensive instrument time. The present review aims to cover the different methodologies applied to the pretreatment of blood prior to LC-MS metabolomic/metabonomic studies. The article tries to critically compare the methods and highlight issues that need to be addressed.

  15. Resting cerebral blood flow, attention, and aging.

    PubMed

    Bertsch, Katja; Hagemann, Dirk; Hermes, Michael; Walter, Christof; Khan, Robina; Naumann, Ewald

    2009-04-24

    Aging is accompanied by a decline of fluid cognitive functions, e.g., a slowing of information processing, working memory, and division of attention. This is at least partly due to structural and functional changes in the aging brain. Although a decrement of resting cerebral blood flow (CBF) has been positively associated with cognitive functions in patients with brain diseases, studies with healthy participants have revealed inconsistent results. Therefore, we investigated the relation between resting cerebral blood flow and cognitive functions (tonic and phasic alertness, selective and divided attention) in two samples of healthy young and older participants. We found higher resting CBF and better cognitive performances in the young than in the older sample. In addition, resting CBF was inversely correlated with selective attention in the young and with tonic alertness in the elderly participants. This finding is discussed with regard to the neural efficiency hypothesis of human intelligence.

  16. Development of a high-sensitivity BGO well counter for small animal PET studies.

    PubMed

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun

    2012-01-01

    In quantitative measurements of small animal PET studies, blood sampling is limited due to the small amounts of blood such animals can provide. In addition, injection doses are quite limited. In this situation, a high-sensitivity well counter would be useful for reducing the amount of the blood sample needed from small animals. Bismuth germinate (BGO) has a high stopping power for high-energy gamma rays compared to NaI(Tl), which is commonly used for conventional well counters. We have developed a BGO well counter and have tested it for blood-sampling measurements in small animals. The BGO well counter uses a square BGO block (59 × 59 × 50 mm) with a square open space (27 × 27 × 34 mm) in the center of the block. The BGO block was optically coupled to a 59-mm square-shaped photomultiplier tube (PMT). Signals from the PMT were digitally processed for the integration and energy window setting. The results showed that the energy spectrum of the BGO well counter measured with a Na-22 point source provided counts that were about 6 times higher for a 1022-keV (511 keV × 2) gamma peak than the spectrum of a 2-in. NaI(Tl) well counter. The relative sensitivity of the developed BGO well counter was 3.4 times higher than that of a NaI(Tl) well counter. The time activity curve of arterial blood was obtained successfully with the BGO well counter for a F-18-FDG study on rat. The BGO well counter will contribute to reducing the amount of sampled blood and to improving the throughput of quantitative measurements in small animal PET studies.

  17. Effectiveness of saliva and fingerprints as alternative specimens to urine and blood in forensic drug testing.

    PubMed

    Kuwayama, Kenji; Miyaguchi, Hajime; Yamamuro, Tadashi; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Inoue, Hiroyuki

    2016-07-01

    In forensic drug testing, it is important to immediately take biological specimens from suspects and victims to prove their drug intake. We evaluated the effectiveness of saliva and fingerprints as alternative specimens to urine and blood in terms of ease of sampling, drug detection sensitivity, and drug detection periods for each specimen type. After four commercially available pharmaceutical products were administered to healthy subjects, each in a single dose, their urine, blood, saliva, and fingerprints were taken at predetermined sampling times over approximately four weeks. Fourteen analytes (the administered drugs and their main metabolites) were extracted from each specimen using simple pretreatments, such as dilution and deproteinization, and were analyzed using liquid chromatography/mass spectrometry (LC/MS). Most of the analytes were detected in saliva and fingerprints, as well as in urine and blood. The time-courses of drug concentrations were similar between urine and fingerprints, and between blood and saliva. Compared to the other compounds, the acidic compounds, for example ibuprofen, acetylsalicylic acid, were more difficult to detect in all specimens. Acetaminophen, dihydrocodeine, and methylephedrine were detected in fingerprints at later sampling times than in urine. However, a relationship between the drug structures and their detection periods in each specimen was not found. Saliva and fingerprints could be easily sampled on site without using special techniques or facilities. In addition, fingerprints could be immediately analyzed after simple and rapid treatment. In cases where it would be difficult to immediately obtain urine and blood, saliva and fingerprints could be effective alternative specimens for drug testing. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Drug residues in serum of dogs receiving anticancer chemotherapy.

    PubMed

    Knobloch, A; Mohring, S A I; Eberle, N; Nolte, I; Hamscher, G; Simon, D

    2010-01-01

    The presence of drug residues in blood samples can represent an occupational hazard. However, studies on cytotoxic drug residues in serum of dogs are lacking in veterinary oncology. To evaluate possible occupational hazards associated with handling of blood samples from dogs receiving oncolytic drugs 7 days after treatment. Twenty-seven client-owned dogs treated for lymphoma or mast cell tumors with vincristine, vinblastine, cyclophosphamide, or doxorubicin. Prospective, observational study. Serum samples were either taken 7 days after administration of vincristine, cyclophosphamide, doxorubicin (lymphoma), and vinblastine (mast cell tumor), or 1-2 days after the last concurrent oral administration of cyclophosphamide (mast cell tumor). Additionally, serum was collected within 5 minutes of treatment. Measurement of drug residues in serum was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS). In 33 samples collected within 5 minute of treatment, the median serum concentrations were vincristine: 37 microg/L (range: 11-87 microg/L), vinblastine: 13 microg/L (range: 13-35 microg/L), cyclophosphamide: 2,484 microg/L (range: 1,209-2,778 microg/L), doxorubicin: 404 microg/L (range: 234-528 microg/L). In 81 serum samples collected 7 days after treatment vinblastine (7 microg/L) was detected in 1 sample, and cyclophosphamide (7 and 9 microg/L) in 2 samples collected 1-2 days after oral administration of cyclophosphamide. Medications were not detected in any of the other samples. Handling of blood samples from dogs receiving oncolytic chemotherapy 7 days after treatment with vincristine, vinblastine, cyclophosphamide, and doxorubicin should not present a health hazard.

  19. BloodSpot: a database of gene expression profiles and transcriptional programs for healthy and malignant haematopoiesis.

    PubMed

    Bagger, Frederik Otzen; Sasivarevic, Damir; Sohi, Sina Hadi; Laursen, Linea Gøricke; Pundhir, Sachin; Sønderby, Casper Kaae; Winther, Ole; Rapin, Nicolas; Porse, Bo T

    2016-01-04

    Research on human and murine haematopoiesis has resulted in a vast number of gene-expression data sets that can potentially answer questions regarding normal and aberrant blood formation. To researchers and clinicians with limited bioinformatics experience, these data have remained available, yet largely inaccessible. Current databases provide information about gene-expression but fail to answer key questions regarding co-regulation, genetic programs or effect on patient survival. To address these shortcomings, we present BloodSpot (www.bloodspot.eu), which includes and greatly extends our previously released database HemaExplorer, a database of gene expression profiles from FACS sorted healthy and malignant haematopoietic cells. A revised interactive interface simultaneously provides a plot of gene expression along with a Kaplan-Meier analysis and a hierarchical tree depicting the relationship between different cell types in the database. The database now includes 23 high-quality curated data sets relevant to normal and malignant blood formation and, in addition, we have assembled and built a unique integrated data set, BloodPool. Bloodpool contains more than 2000 samples assembled from six independent studies on acute myeloid leukemia. Furthermore, we have devised a robust sample integration procedure that allows for sensitive comparison of user-supplied patient samples in a well-defined haematopoietic cellular space. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  20. Utility of capillary microsampling for rat pharmacokinetic studies: Comparison of tail-vein bleed to jugular vein cannula sampling.

    PubMed

    Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas

    2015-01-01

    Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Metabolomic differences in early and late lactation first-parity gilts

    USDA-ARS?s Scientific Manuscript database

    Investigating the metabolome provides the evaluation of all cellular processes occuring while accounting for environmental influence and may provide additional information for selection criteria to fully evolve. Blood samples and body condition measurements were acquired from 68, first-parity gilts ...

  2. Highly Sensitive Bacteriophage-Based Detection of Brucella abortus in Mixed Culture and Spiked Blood

    PubMed Central

    Sergueev, Kirill V.; Filippov, Andrey A.; Nikolich, Mikeljon P.

    2017-01-01

    For decades, bacteriophages (phages) have been used for Brucella species identification in the diagnosis and epidemiology of brucellosis. Traditional Brucella phage typing is a multi-day procedure including the isolation of a pure culture, a step that can take up to three weeks. In this study, we focused on the use of brucellaphages for sensitive detection of the pathogen in clinical and other complex samples, and developed an indirect method of Brucella detection using real-time quantitative PCR monitoring of brucellaphage DNA amplification via replication on live Brucella cells. This assay allowed the detection of single bacteria (down to 1 colony-forming unit per milliliter) within 72 h without DNA extraction and purification steps. The technique was equally efficient with Brucella abortus pure culture and with mixed cultures of B. abortus and α-proteobacterial near neighbors that can be misidentified as Brucella spp., Ochrobactrum anthropi and Afipia felis. The addition of a simple short sample preparation step enabled the indirect phage-based detection of B. abortus in spiked blood, with the same high sensitivity. This indirect phage-based detection assay enables the rapid and sensitive detection of live B. abortus in mixed cultures and in blood samples, and can potentially be applied for detection in other clinical samples and other complex sample types. PMID:28604602

  3. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    PubMed

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.

  4. Microchip Module for Blood Sample Preparation and Nucleic Acid Amplification Reactions

    PubMed Central

    Yuen, Po Ki; Kricka, Larry J.; Fortina, Paolo; Panaro, Nicholas J.; Sakazume, Taku; Wilding, Peter

    2001-01-01

    A computer numerical control-machined plexiglas-based microchip module was designed and constructed for the integration of blood sample preparation and nucleic acid amplification reactions. The microchip module is comprised of a custom-made heater-cooler for thermal cycling, a series of 254 μm × 254 μm microchannels for transporting human whole blood and reagents in and out of an 8–9 μL dual-purpose (cell isolation and PCR) glass-silicon microchip. White blood cells were first isolated from a small volume of human whole blood (<3 μL) in an integrated cell isolation–PCR microchip containing a series of 3.5-μm feature-sized “weir-type” filters, formed by an etched silicon dam spanning the flow chamber. A genomic target, a region in the human coagulation Factor V gene (226-bp), was subsequently directly amplified by microchip-based PCR on DNA released from white blood cells isolated on the filter section of the microchip mounted onto the microchip module. The microchip module provides a convenient means to simplify nucleic acid analyses by integrating two key steps in genetic testing procedures, cell isolation and PCR and promises to be adaptable for additional types of integrated assays. PMID:11230164

  5. Blood lead concentrations in wild birds from a polluted mining region at Villa de La Paz, San Luis Potosi, Mexico.

    PubMed

    Chapa-Vargas, Leonardo; Mejia-Saavedra, Jose J; Monzalvo-Santos, Karina; Puebla-Olivares, Fernando

    2010-01-01

    This investigation was undertaken to determine the concentrations of lead in bird blood samples from a mining region in central Mexico and to compare concentrations among several different feeding guilds. The study took place in the Mexican state of San Luis Potosi in a region known as "Villa de la Paz." This is one of the most intensely exploited mining regions in central Mexico and has been actively mined for over four centuries. Lead concentrations from bird blood samples taken from four polluted sites were significantly higher than those from a control, unpolluted site (F = 6.3, P < 0.0002). Similarly, mean blood lead concentrations in birds from a highly polluted site were higher than those from a site that has intermediate pollution levels (P < 0.05). In addition, samples from insectivorous birds had significantly lower lead concentrations compared to granivores, frugivores-insectivores, and omnivores (F = 4.86, P = 0.004), and a large proportion of all individuals had blood lead concentrations indicative of low, sub-lethal toxic effects. Finally, in two polluted sites, remarkably small numbers of insectivore-frugivores, and granivores were trapped, and in one polluted site a large number of insectivores was trapped (X(2) = 29.9, P = 0.03), and no differences in proportions of migrants and non-migrants were found among sampling sites (X(2) = 0.6, P = 0.96). To date, it has not been determined to what extent constant exposure to these levels of pollution can influence health at the individual level, lifespan, and, therefore, population demography of birds from this region.

  6. Rapid diagnosis of sepsis with TaqMan-Based multiplex real-time PCR.

    PubMed

    Liu, Chang-Feng; Shi, Xin-Ping; Chen, Yun; Jin, Ye; Zhang, Bing

    2018-02-01

    The survival rate of septic patients mainly depends on a rapid and reliable diagnosis. A rapid, broad range, specific and sensitive quantitative diagnostic test is the urgent need. Thus, we developed a TaqMan-Based Multiplex real-time PCR assays to identify bloodstream pathogens within a few hours. Primers and TaqMan probes were designed to be complementary to conserved regions in the 16S rDNA gene of different kinds of bacteria. To evaluate accurately, sensitively, and specifically, the known bacteria samples (Standard strains, whole blood samples) are determined by TaqMan-Based Multiplex real-time PCR. In addition, 30 blood samples taken from patients with clinical symptoms of sepsis were tested by TaqMan-Based Multiplex real-time PCR and blood culture. The mean frequency of positive for Multiplex real-time PCR was 96% at a concentration of 100 CFU/mL, and it was 100% at a concentration greater than 1000 CFU/mL. All the known blood samples and Standard strains were detected positively by TaqMan-Based Multiplex PCR, no PCR products were detected when DNAs from other bacterium were used in the multiplex assay. Among the 30 patients with clinical symptoms of sepsis, 18 patients were confirmed positive by Multiplex real-time PCR and seven patients were confirmed positive by blood culture. TaqMan-Based Multiplex real-time PCR assay with highly sensitivity, specificity and broad detection range, is a rapid and accurate method in the detection of bacterial pathogens of sepsis and should have a promising usage in the diagnosis of sepsis. © 2017 Wiley Periodicals, Inc.

  7. Application of DBS sampling in combination with LC-MS/MS for pharmacokinetic evaluation of a compound with species-specific blood-to-plasma partitioning.

    PubMed

    Xu, Guifen; Chen, Jiyun S; Phadnis, Ruta; Huang, Tom; Uyeda, Craig; Soto, Marcus; Stouch, Brian; Wells, Mary C; James, Christopher A; Carlson, Timothy J

    2012-08-01

    Dried blood spot (DBS) sampling in combination with LC-MS/MS has been used increasingly in drug discovery for quantitative analysis to support pharmacokinetic (PK) studies. In this study, we assessed the effect of blood-to-plasma (B:P) partitioning on the bioanalytical performance and PK data acquired by DBS for a compound AMG-1 with species and concentration-dependent B:P ratio. B:P partitioning did not adversely affect bioanalytical performance of DBS for AMG-1. For rat, (B:P ratio of 0.63), PK profiles from DBS and plasma methods were comparable. For dog, concentration-dependence of B:P ratio was observed both in vivo and in vitro. Additional studies demonstrated concentration-dependence of the compound's unbound fraction in plasma, which may contribute to the concentration-dependence of the B:P ratio. DBS is a promising sampling technique for preclinical pharmacokinetic studies. For compounds with high B:P ratio, caution needs to be applied for data comparison and interpretation between matrices.

  8. Determination of Δ9-tetrahydrocannabinolic acid A (Δ9-THCA-A) in whole blood and plasma by LC-MS/MS and application in authentic samples from drivers suspected of driving under the influence of cannabis.

    PubMed

    Raikos, Nikolaos; Schmid, Helene; Nussbaumer, Susanne; Ambach, Lars; Lanz, Stephan; Längin, Andreas; König, Stefan; Roth, Nadine; Auwärter, Volker; Weinmann, Wolfgang

    2014-10-01

    Delta-9-tetrahydrocannabinolic acid A (THCA-A) is the biosynthetic precursor of delta-9-tetrahydrocannabinol (THC) in cannabis plants, and has no psychotropic effects. THCA-A can be detected in blood and urine, and several metabolites have been identified. THCA-A was also shown to be incorporated in hair by side stream smoke to a minor extent, but incorporation via blood stream or sweat seems unlikely. The detection of THCA-A in biological fluids may serve as a marker for differentiating between the intake of prescribed THC medication - containing only pure THC - and cannabis products containing THC besides THC-acid A and other cannabinoids. However, the knowledge about its usefulness in forensic cases is very limited. The aim of the present work was the development of a reliable method for THCA-A determination in human blood or plasma using LC-MS/MS and application to cases of driving under the influence of drugs. Fifty eight (58) authentic whole blood and the respective plasma samples were collected from drivers suspected of driving under the influence of cannabis from the region of Bern (Switzerland). Samples were first tested for THC, 11-OH-THC and THC-COOH, and then additionally for THCA-A. For this purpose, the existing LC-MS/MS method was modified and validated, and found to be selective and linear over a range of 1.0 to 200ng/mL (the correlation coefficients were above 0.9980 in all validation runs). Limit of detection (LOD) and limit of quantification (LOQ) were 0.3ng/mL and 1.0ng/mL respectively. Intra- and inter-assay accuracy were equal or better than 90% and intra- and inter-assay precision were equal or better than 11.1%. The mean extraction efficiencies were satisfactory being equal or higher than 85.4%. THCA-A was stable in whole blood samples after 3 freeze/thaw cycles and storage at 4°C for 7 days. Re-injection (autosampler) stability was also satisfactory. THC was present in all blood samples with levels ranging from 0.7 to 51ng/mL. THCA-A concentrations ranged from 1.0 to 496ng/mL in blood samples and from 1.4 to 824ng/mL in plasma samples. The plasma:blood partition coefficient had a mean value of 1.7 (±0.21, SD). No correlation was found between the degree of intoxication or impairment stated in the police protocols or reports of medical examinations and the detected THCA-A-concentration in blood. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. A new morphologically distinct avian malaria parasite that fails detection by established polymerase chain reaction-based protocols for amplification of the cytochrome B gene.

    PubMed

    Zehtindjiev, Pavel; Križanauskienė, Asta; Bensch, Staffan; Palinauskas, Vaidas; Asghar, Muhammad; Dimitrov, Dimitar; Scebba, Sergio; Valkiūnas, Gediminas

    2012-06-01

    Plasmodium polymorphum n. sp. (Haemosporida, Plasmodiidae) was found in the skylark, Alauda arvensis (Passeriformes: Alaudidae), during autumnal migration in southern Italy. This organism is illustrated and described based on the morphology of its blood stages. The most distinctive feature of this malaria parasite is the clear preference of its blood stages (trophozoites, meronts, and gametocytes) for immature red blood cells, including erythroblasts. Based on preference of erythrocytic meronts for immature red blood cells, P. polymorphum is most similar to species of the subgenus Huffia . This parasite can be readily distinguished from all other bird malaria parasites, including Plasmodium ( Huffia ) spp., due to preferential development and maturation of its gametocytes in immature red blood cells, a unique character for avian Plasmodium spp. In addition, the margins of nuclei in blood stages of P. polymorphum are markedly smooth and distinct; this is also a distinct diagnostic feature of this parasite. Plasmodium polymorphum has been recorded only in the skylark; it is probably a rare parasite, whose host range and geographical distribution remain unclear. Microscopic examination detected a light infection of Plasmodium relictum (lineage GRW11, parasitemia of <0.01%) in the same sample with P. polymorphum ; the latter parasite clearly predominated (3.5% parasitemia). However, experienced researchers were unable to detect sequences of mitochondrial cytochrome b gene (cyt b ) of P. polymorphum from the microscopically positive sample by using published and newly designed primers for DNA amplification of avian Plasmodium spp. The light parasitemia of P. relictum was easily detectable using several polymerase chain reaction (PCR)-based assays, but P. polymorphum was undetectable in all applied assays. Quantitative PCR also showed the presence of light parasitemia (0.06%) of the lineage GRW11 in this sample. This supports the conclusion that the morphologically distinct parasite observed along with P. relictum and predominant in the sample is genetically dissimilar from the lineage GRW11 based on cyt b sequence. In samples with co-infections, general PCR protocols tend to favor the amplification of the parasite with the higher parasitemia or the amplification with the best matching sequence to the primers. Because the parasitemia of P. polymorphum was >50-fold higher than that of P. relictum and several different primers were tested, we suggest that the failure to amplify P. polymorphum is a more complex problem than why co-infections are commonly overlooked in PCR-based studies. We suggest possible explanations of these results and call for additional research on evolution of mitochondrial genome of hemosporidian parasites.

  10. Lidocaine Concentration in Oral Tissue by the Addition of Epinephrine

    PubMed Central

    Tanaka, Eri; Yoshida, Kenji; Kawaai, Hiroyoshi; Yamazaki, Shinya

    2016-01-01

    The vasoconstrictive effect due to the addition of epinephrine to local anesthetic has been clearly shown by measuring blood-flow volume or blood anesthetic concentration in oral mucosal tissue. However, there are no reports on the measurement of anesthetic concentration using samples directly taken from the jawbone and oral mucosal tissue. Consequently, in this study, the effect of lidocaine concentration in the jawbone and oral mucosal tissue by the addition of epinephrine to the local anesthetic lidocaine was considered by quantitatively measuring lidocaine concentration within the tissue. Japanese white male rabbits (n = 96) were used as test animals. General anesthesia was induced by sevoflurane and oxygen, and then cannulation to the femoral artery was performed while arterial pressure was constantly recorded. Infiltration anesthesia was achieved by 0.5 mL of 2% lidocaine containing 1 : 80,000 epinephrine in the upper jawbone (E+) and 0.5 mL of 2% of epinephrine additive–free lidocaine (E0) under the periosteum. At specified time increments (10, 20, 30, 40, 50, and 60 minutes), samples from the jawbone, oral mucosa, and blood were collected, and lidocaine concentration was directly measured by high-performance liquid chromatography. No significant differences in the change in blood pressure were observed either in E+ or E0. In both E+ and E0 groups, the serum lidocaine concentration peaked 10 minutes after local anesthesia and decreased thereafter. At all time increments, serum lidocaine concentration in E+ was significantly lower than that in E0. There were no significant differences in measured lidocaine concentration between jawbone and mucosa within either the E+ or the E0 groups at all time points, although the E0 group had significantly lower jawbone and mucosa concentrations than the E+ group at all time points when comparing the 2 groups to each other. Addition of epinephrine to the local anesthetic inhibited systemic absorption of local anesthetic into the blood such that a high concentration could be maintained in the tissue. Epinephrine-induced vasoconstrictive effect was observed not only in the oral mucosa but also in the jawbone. PMID:26866407

  11. Avian mercury exposure and toxicological risk across western North America: A synthesis

    USGS Publications Warehouse

    Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark; Hartman, Christopher; Peterson, Sarah; Evers, David C.; Jackson, Allyson K.; Elliott, John E.; Vander Pol, Stacy S.; Bryan, Colleen E.

    2016-01-01

    Methylmercury contamination of the environment is an important issue globally, and birds are useful bioindicators for mercury monitoring programs. The available data on mercury contamination of birds in western North America were synthesized. Original data from multiple databases were obtained and a literature review was conducted to obtain additional mercury concentrations. In total, 29219 original bird mercury concentrations from 225 species were compiled, and an additional 1712 mean mercury concentrations, representing 19998 individuals and 176 species, from 200 publications were obtained. To make mercury data comparable across bird tissues, published equations of tissue mercury correlations were used to convert all mercury concentrations into blood-equivalent mercury concentrations. Blood-equivalent mercury concentrations differed among species, foraging guilds, habitat types, locations, and ecoregions. Piscivores and carnivores exhibited the greatest mercury concentrations, whereas herbivores and granivores exhibited the lowest mercury concentrations. Bird mercury concentrations were greatest in ocean and salt marsh habitats and lowest in terrestrial habitats. Bird mercury concentrations were above toxicity benchmarks in many areas throughout western North America, and multiple hotspots were identified. Additionally, published toxicity benchmarks established in multiple tissues were summarized and translated into a common blood-equivalent mercury concentration. Overall, 66% of birds sampled in western North American exceeded a blood-equivalent mercury concentration of 0.2 μg/g wet weight (ww; above background levels), which is the lowest-observed effect level, 28% exceeded 1.0 μg/g ww (moderate risk), 8% exceeded 3.0 μg/g ww (high risk), and 4% exceeded 4.0 μg/g ww (severe risk). Mercury monitoring programs should sample bird tissues, such as adult blood and eggs, that are most-easily translated into tissues with well-developed toxicity benchmarks and that are directly relevant to bird reproduction. Results indicate that mercury contamination of birds is prevalent in many areas throughout western North America, and large-scale ecological attributes are important factors influencing bird mercury concentrations.

  12. Avian mercury exposure and toxicological risk across western North America: A synthesis

    PubMed Central

    Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark P.; Hartman, C. Alex; Peterson, Sarah H.; Evers, David C.; Jackson, Allyson K.; Elliott, John E.; Vander Pol, Stacy S.; Bryan, Colleen E.

    2017-01-01

    Methylmercury contamination of the environment is an important issue globally and birds are useful bioindicators for mercury monitoring programs. The available data on mercury contamination of birds in western North America were synthesized. Original data from multiple databases were obtained and a literature review was conducted to obtain additional mercury concentrations. In total, 29219 original bird mercury concentrations from 225 species were compiled, and an additional 1712 mean mercury concentrations, representing 19998 individuals and 176 species, from 200 publications were obtained. To make mercury data comparable across bird tissues, published equations of tissue mercury correlations were used to convert all mercury concentrations into blood-equivalent mercury concentrations. Blood-equivalent mercury concentrations differed among species, foraging guilds, habitat types, locations, and ecoregions. Piscivores and carnivores exhibited the greatest mercury concentrations, whereas herbivores and granivores exhibited the lowest mercury concentrations. Bird mercury concentrations were greatest in ocean and salt marsh habitats and lowest in terrestrial habitats. Bird mercury concentrations were above toxicity benchmarks in many areas throughout western North America, and multiple hotspots were identified. Additionally, published toxicity benchmarks established in multiple tissues were summarized and translated into a common blood-equivalent mercury concentration. Overall, 66% of birds sampled in western North American exceeded a blood-equivalent mercury concentration of 0.2 μg/g wet weight (ww; above background levels), which is the lowest-observed effect level, 28% exceeded 1.0 μg/g ww (moderate risk), 8% exceeded 3.0 μg/g ww (high risk), and 4% exceeded 4.0 μg/g ww (severe risk). Mercury monitoring programs should sample bird tissues, such as adult blood and eggs, that are most-easily translated into tissues with well-developed toxicity benchmarks and that are directly relevant to bird reproduction. Results indicate that mercury contamination of birds is prevalent in many areas throughout western North America, and large-scale ecological attributes are important factors influencing bird mercury concentrations. PMID:27093907

  13. Lice outbreak in buffaloes: evidence of Anaplasma marginale transmission by sucking lice Haematopinus tuberculatus.

    PubMed

    Da Silva, Aleksandro Schafer; Lopes, Leandro Sâmia; Diaz, Jorge Damian Stumpfs; Tonin, Alexandre Alberto; Stefani, Lenita Moura; Araújo, Denise Nunes

    2013-06-01

    Lice infestations are commonly seen in buffaloes, causing damage directly to the animal, i.e., itching, skin lesions, and anemia. In addition, these insects can also be vectors for infectious diseases. The present study describes an outbreak of lice in buffaloes as well as evidence for Haematopinus tuberculatus acting as a vector of anaplasmosis. Lice and blood were collected from 4 young buffaloes (2- to 4-mo-old) and a molecular analysis for the presence of Anaplasma marginale was conducted. DNA of A. marginale was detected in the blood of all 4 animals. Twelve lice were collected and separated in 4 groups, with 3 insects each, to comprise a pool of samples. After DNA extraction and molecular analysis, a positive PCR for A. marginale was found in all pooled samples. These results identify sucking lice as potential vectors of anaplasmosis. However, additional studies are necessary to fully evaluate the vector potential of H. tuberculatus for A. maginale transmission.

  14. Concentrations of cadmium, Cobalt, Lead, Nickel, and Zinc in Blood and Fillets of Northern Hog Sucker (Hypentelium nigricans) from streams contaminated by lead-Zinc mining: Implications for monitoring

    USGS Publications Warehouse

    Schmitt, C.J.; Brumbaugh, W.G.; May, T.W.

    2009-01-01

    Lead (Pb) and other metals can accumulate in northern hog sucker (Hypentelium nigricans) and other suckers (Catostomidae), which are harvested in large numbers from Ozark streams by recreational fishers. Suckers are also important in the diets of piscivorous wildlife and fishes. Suckers from streams contaminated by historic Pb-zinc (Zn) mining in southeastern Missouri are presently identified in a consumption advisory because of Pb concentrations. We evaluated blood sampling as a potentially nonlethal alternative to fillet sampling for Pb and other metals in northern hog sucker. Scaled, skin-on, bone-in "fillet" and blood samples were obtained from northern hog suckers (n = 75) collected at nine sites representing a wide range of conditions relative to Pb-Zn mining in southeastern Missouri. All samples were analyzed for cadmium (Cd), cobalt (Co), Pb, nickel (Ni), and Zn. Fillets were also analyzed for calcium as an indicator of the amount of bone, skin, and mucus included in the samples. Pb, Cd, Co, and Ni concentrations were typically higher in blood than in fillets, but Zn concentrations were similar in both sample types. Concentrations of all metals except Zn were typically higher at sites located downstream from active and historic Pb-Zn mines and related facilities than at nonmining sites. Blood concentrations of Pb, Cd, and Co were highly correlated with corresponding fillet concentrations; log-log linear regressions between concentrations in the two sample types explained 94% of the variation for Pb, 73-83% of the variation for Co, and 61% of the variation for Cd. In contrast, relations for Ni and Zn explained <12% of the total variation. Fillet Pb and calcium concentrations were correlated (r = 0.83), but only in the 12 fish from the most contaminated site; concentrations were not significantly correlated across all sites. Conversely, fillet Cd and calcium were correlated across the range of sites (r = 0.78), and the inclusion of calcium in the fillet-to-blood relation explained an additional 12% of the total variation in fillet Cd. Collectively, the results indicate that blood sampling could provide reasonably accurate and precise estimates of fillet Pb, Co, and Cd concentrations that would be suitable for identifying contaminated sites and for monitoring, but some fillet sampling might be necessary at contaminated sites for establishing consumption advisories. ?? 2009 US Government.

  15. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  16. Severe anaemia associated with Plasmodium falciparum infection in children: consequences for additional blood sampling for research.

    PubMed

    Kuijpers, Laura Maria Francisca; Maltha, Jessica; Guiraud, Issa; Kaboré, Bérenger; Lompo, Palpouguini; Devlieger, Hugo; Van Geet, Chris; Tinto, Halidou; Jacobs, Jan

    2016-06-02

    Plasmodium falciparum infection may cause severe anaemia, particularly in children. When planning a diagnostic study on children suspected of severe malaria in sub-Saharan Africa, it was questioned how much blood could be safely sampled; intended blood volumes (blood cultures and EDTA blood) were 6 mL (children aged <6 years) and 10 mL (6-12 years). A previous review [Bull World Health Organ. 89: 46-53. 2011] recommended not to exceed 3.8 % of total blood volume (TBV). In a simulation exercise using data of children previously enrolled in a study about severe malaria and bacteraemia in Burkina Faso, the impact of this 3.8 % safety guideline was evaluated. For a total of 666 children aged >2 months to <12 years, data of age, weight and haemoglobin value (Hb) were available. For each child, the estimated TBV (TBVe) (mL) was calculated by multiplying the body weight (kg) by the factor 80 (ml/kg). Next, TBVe was corrected for the degree of anaemia to obtain the functional TBV (TBVf). The correction factor consisted of the rate 'Hb of the child divided by the reference Hb'; both the lowest ('best case') and highest ('worst case') reference Hb values were used. Next, the exact volume that a 3.8 % proportion of this TBVf would present was calculated and this volume was compared to the blood volumes that were intended to be sampled. When applied to the Burkina Faso cohort, the simulation exercise pointed out that in 5.3 % (best case) and 11.4 % (worst case) of children the blood volume intended to be sampled would exceed the volume as defined by the 3.8 % safety guideline. Highest proportions would be in the age groups 2-6 months (19.0 %; worst scenario) and 6 months-2 years (15.7 %; worst case scenario). A positive rapid diagnostic test for P. falciparum was associated with an increased risk of violating the safety guideline in the worst case scenario (p = 0.016). Blood sampling in children for research in P. falciparum endemic settings may easily violate the proposed safety guideline when applied to TBVf. Ethical committees and researchers should be wary of this and take appropriate precautions.

  17. Ultrastructure of hybrid chitosan-glycerol phosphate blood clots by environmental scanning electron microscopy.

    PubMed

    Iliescu, M; Hoemann, C D; Shive, M S; Chenite, A; Buschmann, M D

    2008-03-01

    Chitosan-based polymers have been extensively studied for biomedical applications. Recently, liquid solutions of chitosan in a glycerol phosphate buffer (chitosan-GP) with physiological pH and osmolality were mixed with autologous blood to form hybrid chitosan-GP/blood implants that improved the repair of articular cartilage lesions in a large animal model. The mixture of chitosan-GP and blood forms a viscous liquid, which solidifies in minutes via normal blood coagulation as well as chitosan-mediated mechanisms. Here we have examined the ultrastructure of these chitosan-GP/blood clots as well as regular blood clots and chitosan-GP gels, the latter produced by heating. Both unfixed and fixed samples of chitosan-GP/blood clots, regular blood clots, and chitosan-GP gels were investigated by environmental scanning electron microscopy (ESEM) in conjunction with energy dispersive X-ray spectrometry (EDS), the former permitting direct observation of the ultrastructure in hydrated conditions simulating the natural state. By examination of unfixed specimens using ESEM we found that chitosan formed a network structure in both chitosan-GP gels and chitosan-GP/blood clots; however this structure was altered by aldehyde fixation to produce artifactual aggregates of chitosan microparticles. We were also able to identify chitosan in chitosan-GP/blood clots by washing samples in low concentration NaCl solutions followed by local EDS analyses to identify excess chloride versus sodium, and thus presence of cationic chitosan in analyzed features. Additional results indicated that the majority of glycerol phosphate diffuses freely from chitosan-GP gels (by EDS of phosphorus) and that hyperosmotic paraformaldehyde-based fixatives (i.e. 4% w/v) significantly disturb erythrocyte morphology in fixed whole blood clots. (c) 2007 Wiley-Liss, Inc.

  18. Noncontact discrimination of animal and human blood with vacuum blood vessel and factors affect the discrimination

    NASA Astrophysics Data System (ADS)

    Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Li, Hongxiao; Li, Yingxin; Fu, Zhigang; Guan, Yang; Li, Gang; Lin, Ling

    2017-03-01

    Discrimination of human and nonhuman blood is crucial for import-export ports and inspection and quarantine departments. Current methods are usually destructive, complicated and time-consuming. We had previously demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize human blood discrimination. In that research, the spectra were measured with the fiber probe under the surface of blood samples. However, open sampling may pollute the blood samples. Virulence factors in blood samples can also endanger inspectors. In this paper, we explored the classification effect with the blood samples measured in the original containers-vacuum blood vessel. Furthermore, we studied the impact of different conditions of blood samples, such as coagulation and hemolysis, on the prediction ability of the discrimination model. The calibration model built with blood samples in different conditions displayed a satisfactory prediction result. This research demonstrated that visible and near-infrared diffuse reflectance spectroscopy method was potential for noncontact discrimination of human blood.

  19. Cost-effectiveness of additional blood screening tests in the Netherlands.

    PubMed

    Borkent-Raven, Barbara A; Janssen, Mart P; van der Poel, Cees L; Bonsel, Gouke J; van Hout, Ben A

    2012-03-01

    During the past decade, blood screening tests such as triplex nucleic acid amplification testing (NAT) and human T-cell lymphotropic virus type I or I (HTLV-I/II) antibody testing were added to existing serologic testing for hepatitis B virus (HBV), human immunodeficiency virus (HIV), and hepatitis C virus (HCV). In some low-prevalence regions these additional tests yielded disputable benefits that can be valuated by cost-effectiveness analyses (CEAs). CEAs are used to support decision making on implementation of medical technology. We present CEAs of selected additional screening tests that are not uniformly implemented in the EU. Cost-effectiveness was analyzed of: 1) HBV, HCV, and HIV triplex NAT in addition to serologic testing; 2) HTLV-I/II antibody test for all donors, for first-time donors only, and for pediatric recipients only; and 3) hepatitis A virus (HAV) for all donations. Disease progression of the studied viral infections was described in five Markov models. In the Netherlands, the incremental cost-effectiveness ratio (ICER) of triplex NAT is €5.20 million per quality-adjusted life-year (QALY) for testing minipools of six donation samples and €4.65 million/QALY for individual donation testing. The ICER for anti-HTLV-I/II is €45.2 million/QALY if testing all donations, €2.23 million/QALY if testing new donors only, and €27.0 million/QALY if testing blood products for pediatric patients only. The ICER of HAV NAT is €18.6 million/QALY. The resulting ICERs are very high, especially when compared to other health care interventions. Nevertheless, these screening tests are implemented in the Netherlands and elsewhere. Policy makers should reflect more explicit on the acceptability of costs and effects whenever additional blood screening tests are implemented. © 2011 American Association of Blood Banks.

  20. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  1. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  2. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  3. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  4. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  5. The evaluation of a positive direct antiglobulin test (autocontrol) in pretransfusion testing revisited.

    PubMed

    Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H

    1986-01-01

    Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.

  6. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    PubMed

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  7. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl.

    PubMed

    Smith, Matthew M; Schmutz, Joel; Apelgren, Chloe; Ramey, Andrew M

    2015-04-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n=105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R(2)=0.694, P=0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species. Published by Elsevier B.V.

  8. Haematology and plasma chemistry of the red top ice blue mbuna cichlid (Metriaclima greshakei).

    PubMed

    Snellgrove, Donna L; Alexander, Lucille G

    2011-10-01

    Clinical haematology and blood plasma chemistry can be used as a valuable tool to provide substantial diagnostic information for fish. A wide range of parameters can be used to assess nutritional status, digestive function, disease identification, routine metabolic levels, general physiological status and even the assessment and management of wild fish populations. However to evaluate such data accurately, baseline reference intervals for each measurable parameter must be established for the species of fish in question. Baseline data for ornamental fish species are limited, as research is more commonly conducted using commercially cultured fish. Blood samples were collected from sixteen red top ice blue cichlids (Metriaclima greshakei), an ornamental freshwater fish, to describe a range of haematology and plasma chemistry parameters. Since this cichlid is fairly large in comparison with most tropical ornamental fish, two independent blood samples were taken to assess a large range of parameters. No significant differences were noted between sample periods for any parameter. Values obtained for a large number of parameters were similar to those established for other closely related fish species such as tilapia (Oreochromis spp.). In addition to reporting the first set of blood values for M. Greshakei, to our knowledge, this study highlights the possibility of using previously established data for cultured cichlid species in studies with ornamental cichlid fish.

  9. Clinical utility of an optimised multiplex real-time PCR assay for the identification of pathogens causing sepsis in Vietnamese patients.

    PubMed

    Tat Trung, Ngo; Van Tong, Hoang; Lien, Tran Thi; Van Son, Trinh; Thanh Huyen, Tran Thi; Quyen, Dao Thanh; Hoan, Phan Quoc; Meyer, Christian G; Song, Le Huu

    2018-02-01

    For the identification of bacterial pathogens, blood culture is still the gold standard diagnostic method. However, several disadvantages apply to blood cultures, such as time and rather large volumes of blood sample required. We have previously established an optimised multiplex real-time PCR method in order to diagnose bloodstream infections. In the present study, we evaluated the diagnostic performance of this optimised multiplex RT-PCR in blood samples collected from 110 septicaemia patients enrolled at the 108 Military Central Hospital, Hanoi, Vietnam. Positive results were obtained by blood culture, the Light Cylcler-based SeptiFast ® assay and our multiplex RT-PCR in 35 (32%), 31 (28%), and 31 (28%) samples, respectively. Combined use of the three methods confirmed 50 (45.5%) positive cases of bloodstream infection, a rate significantly higher compared to the exclusive use of one of the three methods (P=0.052, 0.012 and 0.012, respectively). The sensitivity, specificity and area under the curve (AUC) of our assay were higher compared to that of the SeptiFast ® assay (77.4%, 86.1% and 0.8 vs. 67.7%, 82.3% and 0.73, respectively). Combined use of blood culture and multiplex RT-PCR assay showed a superior diagnostic performance, as the sensitivity, specificity, and AUC reached 83.3%, 100%, and 0.95, respectively. The concordance between blood culture and the multiplex RT-PCR assay was highest for Klebsiella pneumonia (100%), followed by Streptococcus spp. (77.8%), Escherichia coli (66.7%), Staphylococcus spp. (50%) and Salmonella spp. (50%). In addition, the use of the newly established multiplex RT-PCR assay increased the spectrum of identifiable agents (Acintobacter baumannii, 1/32; Proteus mirabilis, 1/32). The combination of culture and the multiplex RT-PCR assay provided an excellent diagnostic accomplishment and significantly supported the identification of causative pathogens in clinical samples obtained from septic patients. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Successful downstream application of the Paxgene Blood RNA system from small blood samples in paediatric patients for quantitative PCR analysis

    PubMed Central

    Carrol, Enitan D; Salway, Fiona; Pepper, Stuart D; Saunders, Emma; Mankhambo, Limangeni A; Ollier, William E; Hart, C Anthony; Day, Phillip

    2007-01-01

    Background The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. Results Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). Conclusion We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis. PMID:17850649

  11. Inhibitory Effect of Flavonolignans on the P2Y12 Pathway in Blood Platelets.

    PubMed

    Bijak, Michal; Szelenberger, Rafal; Dziedzic, Angela; Saluk-Bijak, Joanna

    2018-02-10

    Adenosine diphosphate (ADP) is the major platelet agonist, which is important in the shape changes, stability, and growth of the thrombus. Platelet activation by ADP is associated with the G protein-coupled receptors P2Y1 and P2Y12. The pharmacologic blockade of the P2Y12 receptor significantly reduces the risk of peripheral artery disease, myocardial infarction, ischemic stroke, and vascular death. Recent studies demonstrated the inhibition of ADP-induced blood platelet activation by three major compounds of the flavonolignans group: silybin, silychristin, and silydianin. For this reason, the aim of the current work was to verify the effects of silybin, silychristin, and silydianin on ADP-induced physiological platelets responses, as well as mechanisms of P2Y12-dependent intracellular signal transduction. We evaluated the effect of tested flavonolignans on ADP-induced blood platelets' aggregation in platelet-rich plasma (PRP) (using light transmission aggregometry), adhesion to fibrinogen (using the static method), and the secretion of PF-4 (using the ELISA method). Additionally, using the double labeled flow cytometry method, we estimated platelet vasodilator-stimulated phosphoprotein (VASP) phosphorylation. We demonstrated a dose-dependent reduction of blood platelets' ability to perform ADP-induced aggregation, adhere to fibrinogen, and secrete PF-4 in samples treated with flavonolignans. Additionally, we observed that all of the tested flavonolignans were able to increase VASP phosphorylation in blood platelets samples, which is correlated with P2Y12 receptor inhibition. All of these analyses show that silychristin and silybin have the strongest inhibitory effect on blood platelet activation by ADP, while silydianin also inhibits the ADP pathway, but to a lesser extent. The results obtained in this study clearly demonstrate that silybin, silychristin, and silydianin have inhibitory properties against the P2Y12 receptor and block ADP-induced blood platelet activation.

  12. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    PubMed

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.

  13. Photothermal technique in cell microscopy studies

    NASA Astrophysics Data System (ADS)

    Lapotko, Dmitry; Chebot'ko, Igor; Kutchinsky, Georgy; Cherenkevitch, Sergey

    1995-01-01

    Photothermal (PT) method is applied for a cell imaging and quantitative studies. The techniques for cell monitoring, imaging and cell viability test are developed. The method and experimental set up for optical and PT-image acquisition and analysis is described. Dual- pulsed laser set up combined with phase contrast illumination of a sample provides visualization of temperature field or absorption structure of a sample with spatial resolution 0.5 micrometers . The experimental optics, hardware and software are designed using the modular principle, so the whole set up can be adjusted for various experiments: PT-response monitoring or photothermal spectroscopy studies. Sensitivity of PT-method provides the imaging of the structural elements of live (non-stained) white blood cells. The results of experiments with normal and subnormal blood cells (red blood cells, lymphocytes, neutrophyles and lymphoblasts) are reported. Obtained PT-images are different from optical analogs and deliver additional information about cell structure. The quantitative analysis of images was used for cell population comparative diagnostic. The viability test for red blood cell differentiation is described. During the study of neutrophyles in norma and sarcoidosis disease the differences in PT-images of cells were found.

  14. Diagnosis of Carrion’s Disease by Direct Blood PCR in Thin Blood Smear Negative Samples

    PubMed Central

    Tinco Valdez, Carmen; Pons, Maria J.; del Valle, Luis J.; Oré, Verónica Casabona; Michelena, Denisse Champin; Mayra, Jorge Bazán; Gavidea, Víctor Zavaleta; Vargas, Martha; Ruiz, Joaquim

    2014-01-01

    Bartonella bacilliformis is the etiologic agent of Carrion's disease. This disease has two well established phases, the most relevant being the so called Oroya Fever, in which B. bacilliformis infect the erythrocytes resulting in severe anemia and transient immunosuppression, with a high lethality in the absence of adequate antibiotic treatment. The presence of B. bacilliformis was studied in 113 blood samples suspected of Carrion’s disease based on clinical criteria, despite the absence of a positive thin blood smear, by two different PCR techniques (using Bartonella-specific and universal 16S rRNA gene primers), and by bacterial culture. The specific 16S rRNA gene primers revealed the presence of 21 B. bacilliformis and 1 Bartonella elizabethae, while universal primers showed both the presence of 3 coinfections in which a concomitant pathogen was detected plus Bartonella, in addition to the presence of infections by other microorganisms such as Agrobacterium or Bacillus firmus. These data support the need to implement molecular tools to diagnose Carrion’s disease. PMID:24651298

  15. Chemistry Testing on Plasma Versus Serum Samples in Dialysis Patients: Clinical and Quality Improvement Implications.

    PubMed

    Carey, Roger Neill; Jani, Chinu; Johnson, Curtis; Pearce, Jim; Hui-Ng, Patricia; Lacson, Eduardo

    2016-09-07

    Plasma samples collected in tubes containing separator gels have replaced serum samples for most chemistry tests in many hospital and commercial laboratories. Use of plasma samples for blood tests in the dialysis population eliminates delays in sample processing while waiting for clotting to complete, laboratory technical issues associated with fibrin formation, repeat sample collection, and patient care issues caused by delay of results because of incompletely clotted specimens. Additionally, a larger volume of plasma is produced than serum for the same amount of blood collected. Plasma samples are also acceptable for most chemical tests involved in the care of patients with ESRD. This information becomes very important when United States regulatory requirements for ESRD inadvertently limit the type of sample that can be used for government reporting, quality assessment, and value-based payment initiatives. In this narrative, we summarize the renal community experience and how the subsequent resolution of the acceptability of phosphorus levels measured from serum and plasma samples may have significant implications in the country's continued development of a value-based Medicare ESRD Quality Incentive Program. Copyright © 2016 by the American Society of Nephrology.

  16. Towards Clinical Applications of Blood-Borne miRNA Signatures: The Influence of the Anticoagulant EDTA on miRNA Abundance.

    PubMed

    Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart

    2015-01-01

    Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions.

  17. A Whole Methylome CpG-SNP Association Study of Psychosis in Blood and Brain Tissue.

    PubMed

    van den Oord, Edwin J C G; Clark, Shaunna L; Xie, Lin Ying; Shabalin, Andrey A; Dozmorov, Mikhail G; Kumar, Gaurav; Vladimirov, Vladimir I; Magnusson, Patrik K E; Aberg, Karolina A

    2016-07-01

    Mutated CpG sites (CpG-SNPs) are potential hotspots for human diseases because in addition to the sequence variation they may show individual differences in DNA methylation. We performed methylome-wide association studies (MWAS) to test whether methylation differences at those sites were associated with schizophrenia. We assayed all common CpG-SNPs with methyl-CpG binding domain protein-enriched genome sequencing (MBD-seq) using DNA extracted from 1408 blood samples and 66 postmortem brain samples (BA10) of schizophrenia cases and controls. Seven CpG-SNPs passed our FDR threshold of 0.1 in the blood MWAS. Of the CpG-SNPs methylated in brain, 94% were also methylated in blood. This significantly exceeded the 46.2% overlap expected by chance (P-value < 1.0×10(-8)) and justified replicating findings from blood in brain tissue. CpG-SNP rs3796293 in IL1RAP replicated (P-value = .003) with the same direction of effects. This site was further validated through targeted bisulfite pyrosequencing in 736 independent case-control blood samples (P-value < 9.5×10(-4)). Our top result in the brain MWAS (P-value = 8.8×10(-7)) was CpG-SNP rs16872141 located in the potential promoter of ENC1. Overall, our results suggested that CpG-SNP methylation may reflect effects of environmental insults and can provide biomarkers in blood that could potentially improve disease management. © The Author 2015. Published by Oxford University Press on behalf of the Maryland Psychiatric Research Center. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Assessing the toxic effects of DMSO on cord blood to determine exposure time limits and the optimum concentration for cryopreservation.

    PubMed

    Fry, L J; Querol, S; Gomez, S G; McArdle, S; Rees, R; Madrigal, J A

    2015-08-01

    Advantages of using cord blood (CB) over other sources of haematopoietic progenitor cells, such as bone marrow, include the ability to cryopreserve and bank the samples until requested for a transplant. Cryopreservation requires the addition of a cryoprotectant to prevent the formation of intracellular ice during freezing. Dimethyl sulphoxide (DMSO) is commonly used at a concentration of 10% (v/v); however, there is evidence to suggest this chemical is toxic to cells as well as to patients after infusion. The toxic effects of DMSO were assessed through cell viability and in vitro functional assays in fresh and post-thaw CB samples before determining the maximum exposure time and optimal concentration for cryopreservation. A dose-dependent toxicity of DMSO was observed in fresh samples with 40% removing all viable and functional haematopoietic progenitor cells (HPC). In fresh and post-thaw analysis, minimal toxic effect was observed when cryopreservation was delayed for up to 1 h after 10% DMSO addition. After thawing, DMSO washout was superior to dilution or unmanipulated when maintained for long periods (advantage observed 1 h after thawing). Finally, the optimum concentration for cryopreserving CB was found to be 7.5 to 10% with detrimental effects observed outside of this range. These results support the use of 7.5-10% as the optimal DMSO concentration and the maximum exposure time should be limited to <1 h prior to freezing and 30 min post-thaw. © 2015 International Society of Blood Transfusion.

  19. Antenatal blood pressure for prediction of pre-eclampsia, preterm birth, and small for gestational age babies: development and validation in two general population cohorts

    PubMed Central

    Silverwood, Richard J; de Stavola, Bianca L; Inskip, Hazel; Cooper, Cyrus; Godfrey, Keith M; Crozier, Sarah; Fraser, Abigail; Nelson, Scott M; Lawlor, Debbie A; Tilling, Kate

    2015-01-01

    Study question Can routine antenatal blood pressure measurements between 20 and 36 weeks’ gestation contribute to the prediction of pre-eclampsia and its associated adverse outcomes? Methods This study used repeated antenatal measurements of blood pressure from 12 996 women in the Avon Longitudinal Study of Parents and Children (ALSPAC) to develop prediction models and validated these in 3005 women from the Southampton Women’s Survey (SWS). A model based on maternal early pregnancy characteristics only (BMI, height, age, parity, smoking, existing and previous gestational hypertension and diabetes, and ethnicity) plus initial mean arterial pressure was compared with a model additionally including current mean arterial pressure, a model including the deviation of current mean arterial pressure from a stratified normogram, and a model including both at different gestational ages from 20-36 weeks. Study answer and limitations The addition of blood pressure measurements from 28 weeks onwards improved prediction models compared with use of early pregnancy risk factors alone, but they contributed little to the prediction of preterm birth or small for gestational age. Though multiple imputation of missing data was used to increase the sample size and minimise selection bias, the validation sample might have been slightly underpowered as the number of cases of pre-eclampsia was just below the recommended 100. Several risk factors were self reported, potentially introducing measurement error, but this reflects how information would be obtained in clinical practice. What this study adds The addition of routinely collected blood pressure measurements from 28 weeks onwards improves predictive models for pre-eclampsia based on blood pressure in early pregnancy and other characteristics, facilitating a reduction in scheduled antenatal care. Funding, competing interests, data sharing UK Wellcome Trust, US National Institutes of Health, and UK Medical Research Council. Other funding sources for authors are detailed in the full online paper. With the exceptions of CM-W, HMI, and KMG there were no competing interests. PMID:26578347

  20. Comparison of DNA extraction methods used to detect bacterial and yeast DNA from spiked whole blood by real-time PCR.

    PubMed

    Dalla-Costa, Libera M; Morello, Luis G; Conte, Danieli; Pereira, Luciane A; Palmeiro, Jussara K; Ambrosio, Altair; Cardozo, Dayane; Krieger, Marco A; Raboni, Sonia M

    2017-09-01

    Sepsis is the leading cause of death in intensive care units (ICUs) worldwide and its diagnosis remains a challenge. Blood culturing is the gold standard technique for blood stream infection (BSI) identification. Molecular tests to detect pathogens in whole blood enable early use of antimicrobials and affect clinical outcomes. Here, using real-time PCR, we evaluated DNA extraction using seven manual and three automated commercially available systems with whole blood samples artificially contaminated with Escherichia coli, Staphylococcus aureus, and Candida albicans, microorganisms commonly associated with BSI. Overall, the commercial kits evaluated presented several technical limitations including long turnaround time and low DNA yield and purity. The performance of the kits was comparable for detection of high microorganism loads (10 6 CFU/mL). However, the detection of lower concentrations was variable, despite the addition of pre-processing treatment to kits without such steps. Of the evaluated kits, the UMD-Universal CE IVD kit generated a higher quantity of DNA with greater nucleic acid purity and afforded the detection of the lowest microbial load in the samples. The inclusion of pre-processing steps with the kit seems to be critical for the detection of microorganism DNA directly from whole blood. In conclusion, future application of molecular techniques will require overcoming major challenges such as the detection of low levels of microorganism nucleic acids amidst the large quantity of human DNA present in samples or differences in the cellular structures of etiological agents that can also prevent high-quality DNA yields. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. High-speed shaking of frozen blood clots for extraction of human and malaria parasite DNA

    PubMed Central

    2011-01-01

    Background Frozen blood clots remaining after serum collection is an often disregarded source of host and pathogen DNA due to troublesome handling and suboptimal outcome. Methods High-speed shaking of clot samples in a cell disruptor manufactured for homogenization of tissue and faecal specimens was evaluated for processing frozen blood clots for DNA extraction. The method was compared to two commercial clot protocols based on a chemical kit and centrifugation through a plastic sieve, followed by the same DNA extraction protocol. Blood clots with different levels of parasitaemia (1-1,000 p/μl) were prepared from parasite cultures to assess sensitivity of PCR detection. In addition, clots retrieved from serum samples collected within two epidemiological studies in Kenya (n = 630) were processed by high speed shaking and analysed by PCR for detection of malaria parasites and the human α-thalassaemia gene. Results High speed shaking succeeded in fully dispersing the clots and the method generated the highest DNA yield. The level of PCR detection of P. falciparum parasites and the human thalassaemia gene was the same as samples optimally collected with an anticoagulant. The commercial clot protocol and centrifugation through a sieve failed to fully dissolve the clots and resulted in lower sensitivity of PCR detection. Conclusions High speed shaking was a simple and efficacious method for homogenizing frozen blood clots before DNA purification and resulted in PCR templates of high quality both from humans and malaria parasites. This novel method enables genetic studies from stored blood clots. PMID:21824391

  2. Post-mortem detection of gasoline residues in lung tissue and heart blood of fire victims.

    PubMed

    Pahor, Kevin; Olson, Greg; Forbes, Shari L

    2013-09-01

    The purpose of this study was to determine whether gasoline residues could be detected post-mortem in lung tissue and heart blood of fire victims. The lungs and heart blood were investigated to determine whether they were suitable samples for collection and could be collected without contamination during an autopsy. Three sets of test subjects (pig carcasses) were investigated under two different fire scenarios. Test subjects 1 were anaesthetized following animal ethics approval, inhaled gasoline vapours for a short period and then euthanized. The carcasses were clothed and placed in a house where additional gasoline was poured onto the carcass post-mortem in one fire, but not in the other. Test subjects 2 did not inhale gasoline, were clothed and placed in the house and had gasoline poured onto them in both fires. Test subjects 3 were clothed but had no exposure to gasoline either ante- or post-mortem. Following controlled burns and suppression with water, the carcasses were collected, and their lungs and heart blood were excised at a necropsy. The headspace from the samples was analysed using thermal desorption-gas chromatography-mass spectroscopy. Gasoline was identified in the lungs and heart blood from the subjects that were exposed to gasoline vapours prior to death (test subjects 1). All other samples were negative for gasoline residues. These results suggest that it is useful to analyse for volatile ignitable liquids in lung tissue and blood as it may help to determine whether a victim was alive and inhaling gases at the time of a fire.

  3. Sample preparation method influences direct identification of anaerobic bacteria from positive blood culture bottles using MALDI-TOF MS.

    PubMed

    Jeverica, Samo; Nagy, Elisabeth; Mueller-Premru, Manica; Papst, Lea

    2018-05-15

    Rapid detection and identification of anaerobic bacteria from blood is important to adjust antimicrobial therapy by including antibiotics with activity against anaerobic bacteria. Limited data is available about direct identification of anaerobes from positive blood culture bottles using MALDI-TOF mass spectrometry (MS). In this study, we evaluated the performance of two sample preparation protocols for direct identification of anaerobes from positive blood culture bottles, the MALDI Sepsityper kit (Sepsityper) and the in-house saponin (saponin) method. Additionally, we compared two blood culture bottle types designed to support the growth of anaerobic bacteria, the BacT/ALERT-FN Plus (FN Plus) and the BACTEC-Lytic (Lytic), and their influence on direct identification. A selection of 30 anaerobe strains belonging to 22 different anaerobic species (11 reference strains and 19 clinical isolates) were inoculated to 2 blood culture bottle types in duplicate. In total, 120 bottles were inoculated and 99.2% (n = 119) signalled growth within 5 days of incubation. The Sepsityper method correctly identified 56.3% (n = 67) of anaerobes, while the saponin method correctly identified 84.9% (n = 101) of anaerobes with at least log(score) ≥1.6 (low confidence correct identification), (p < 0.001). Gram negative anaerobes were better identified with the saponin method (100% vs. 46.5%; p < 0.001), while Gram positive anaerobes were better identified with the Sepsityper method (70.8% vs. 62.5%; p = 0.454). Average log(score) values among only those isolates that were correctly identified simultaneously by both sample preparation methods were 2.119 and 2.029 in favour of the Sepsityper method, (p = 0.019). The inoculated bottle type didn't influence the performance of the two sample preparation methods. We confirmed that direct identification from positive blood culture bottles with MALDI-TOF MS is reliable for anaerobic bacteria. However, the results are influenced by the sample preparation method used. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. An Acute Ocfentanil Fatality: A Case Report with Postmortem Concentrations.

    PubMed

    Dussy, F E; Hangartner, S; Hamberg, C; Berchtold, C; Scherer, U; Schlotterbeck, G; Wyler, D; Briellmann, T A

    2016-11-01

    A 24-year-old man known to consume illegal drugs was found dead in his apartment. A reclosable plastic zipper bag containing several hundred milligrams of a brown powder was found close to the dead body and the first assumption of the investigators was death due to heroin intoxication. Therefore, a legal autopsy was ordered. The following toxicological analysis revealed ocfentanil in urine and in the brown powder. Four different approaches for the determination of the ocfentanil concentrations in peripheral whole blood are described. Enrichment of ocfentanil from the powder was realized. With this reference, it was possible to determine the ocfentanil concentration in the seized powder to be 0.91%. Concentrations of ocfentanil were also determined in the sampled body fluids using the standard addition procedure. In peripheral blood 9.1 µg/L, in heart blood 27.9 µg/L and in urine 480 µg/L were measured. In addition, the antidepressant citalopram, the neuroleptic quetiapine and cannabinoids were found in urine and subsequently quantified in peripheral blood. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. [Automated procedures for microscopic analyses of blood smears: medical testing a MECOS-Ts2 complex].

    PubMed

    Pliasunova, S A; Balugian, R Sh; Khmel'nitskiĭ, K E; Medovyĭ, V S; Parpara, A A; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Dem'ianov, V L; Nikolaenko, D S

    2006-10-01

    The paper presents the results of medical tests of a group of computer-aided procedures for microscopic analysis by means of a MECOS-Ts2 complex (ZAO "MECOS", Russia), which have been conducted at the Republican Children's Clinical Hospital, the Research Institute of Emergency Pediatric Surgery and Traumatology, and Moscow City Clinical Hospital No. 23. Computer-aided procedures for calculating the differential count and for analyzing the morphology of red blood cells were tested on blood smears from a total of 443 patients and donors, computer-aided calculation of the count of reticulocytes was tested on 318 smears. The tests were carried out under the US standard NCCLS-H20A. Manual microscopy (443 smears) and flow blood analysis on a Coulter GEN*S (125 smears) were used as reference methods. The quality of collection of samples and laboriousness were additionally assessed. The certified MECOS-Ts2 subsystems were additionally used as reference tools. The tests indicated the advantage of computer-aided MECOS-Tsl2 complex microscopy over manual microscopy.

  6. Automated genomic DNA purification options in agricultural applications using MagneSil paramagnetic particles

    NASA Astrophysics Data System (ADS)

    Bitner, Rex M.; Koller, Susan C.

    2002-06-01

    The automated high throughput purification of genomic DNA form plant materials can be performed using MagneSil paramagnetic particles on the Beckman-Coulter FX, BioMek 2000, and the Tecan Genesis robot. Similar automated methods are available for DNA purifications from animal blood. These methods eliminate organic extractions, lengthy incubations and cumbersome filter plates. The DNA is suitable for applications such as PCR and RAPD analysis. Methods are described for processing traditionally difficult samples such as those containing large amounts of polyphenolics or oils, while still maintaining a high level of DNA purity. The robotic protocols have ben optimized for agricultural applications such as marker assisted breeding, seed-quality testing, and SNP discovery and scoring. In addition to high yield purification of DNA from plant samples or animal blood, the use of Promega's DNA-IQ purification system is also described. This method allows for the purification of a narrow range of DNA regardless of the amount of additional DNA that is present in the initial sample. This simultaneous Isolation and Quantification of DNA allows the DNA to be used directly in applications such as PCR, SNP analysis, and RAPD, without the need for separate quantitation of the DNA.

  7. Vector-Borne Diseases in Stray Dogs in Peninsular Malaysia and Molecular Detection of Anaplasma and Ehrlichia spp. from Rhipicephalus sanguineus (Acari: Ixodidae) Ticks.

    PubMed

    Koh, Fui Xian; Panchadcharam, Chandrawathani; Tay, Sun Tee

    2016-01-01

    Little data are available on the prevalence and transmission of vector-borne diseases in stray dogs in Peninsular Malaysia. This study was designed to determine the occurrence of vector-borne pathogens in Malaysian stray dogs using serological and molecular approaches. In total, 48 dog blood samples were subjected to serological analysis using SNAP 4Dx kit (IDEXX Laboratories, Westbrook, ME). The presence of Ehrlichia and Anaplasma DNA in the dog blood samples and Rhipicephalus sanguineus (Latreille) ticks was detected using nested polymerase chain reaction assays. Positive serological findings against Ehrlichia canis and Anaplasma phagocytophilum were obtained in 17 (39.5%) and four (9.3%) of 43 dog samples, respectively. None of the dog blood samples were positive for Borrelia burgdorferi and Dirofilaria immitis. DNA of E. canis and A. phagocytophilum was detected in 12 (25.5%) and two (4.3%) of 47 dog blood samples, and 17 (51.5%) and one (3.0%) of 33 R. sanguineus ticks, respectively. Additionally, DNA of Ehrlichia spp. closely related to Ehrlichia chaffeensis was detected in two (6.1%) R. sanguineus ticks. This study highlights the prevalence of anaplasmosis and ehrlichiosis in dogs in Malaysia. Due to the zoonotic potential of Ehrlichia and Anaplasma spp., appropriate measures should be instituted for prevention and control of vector-borne diseases in dogs. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Improved age determination of blood and teeth samples using a selected set of DNA methylation markers

    PubMed Central

    Kamalandua, Aubeline

    2015-01-01

    Age estimation from DNA methylation markers has seen an exponential growth of interest, not in the least from forensic scientists. The current published assays, however, can still be improved by lowering the number of markers in the assay and by providing more accurate models to predict chronological age. From the published literature we selected 4 age-associated genes (ASPA, PDE4C, ELOVL2, and EDARADD) and determined CpG methylation levels from 206 blood samples of both deceased and living individuals (age range: 0–91 years). This data was subsequently used to compare prediction accuracy with both linear and non-linear regression models. A quadratic regression model in which the methylation levels of ELOVL2 were squared showed the highest accuracy with a Mean Absolute Deviation (MAD) between chronological age and predicted age of 3.75 years and an adjusted R2 of 0.95. No difference in accuracy was observed for samples obtained either from living and deceased individuals or between the 2 genders. In addition, 29 teeth from different individuals (age range: 19–70 years) were analyzed using the same set of markers resulting in a MAD of 4.86 years and an adjusted R2 of 0.74. Cross validation of the results obtained from blood samples demonstrated the robustness and reproducibility of the assay. In conclusion, the set of 4 CpG DNA methylation markers is capable of producing highly accurate age predictions for blood samples from deceased and living individuals PMID:26280308

  9. Detection of sepsis in patient blood samples using CD64 expression in a microfluidic cell separation device.

    PubMed

    Zhang, Ye; Li, Wenjie; Zhou, Yun; Johnson, Amanda; Venable, Amanda; Hassan, Ahmed; Griswold, John; Pappas, Dimitri

    2017-12-18

    A microfluidic affinity separation device was developed for the detection of sepsis in critical care patients. An affinity capture method was developed to capture cells based on changes in CD64 expression in a single, simple microfluidic chip for sepsis detection. Both sepsis patient samples and a laboratory CD64+ expression model were used to validate the microfluidic assay. Flow cytometry analysis showed that the chip cell capture had a linear relationship with CD64 expression in laboratory models. The Sepsis Chip detected an increase in upregulated neutrophil-like cells when the upregulated cell population is as low as 10% of total cells spiked into commercially available aseptic blood samples. In a proof of concept study, blood samples obtained from sepsis patients within 24 hours of diagnosis were tested on the chip to further validate its performance. On-chip CD64+ cell capture from 10 patient samples (619 ± 340 cells per chip) was significantly different from control samples (32 ± 11 cells per chip) and healthy volunteer samples (228 ± 95 cells per chip). In addition, the on-chip cell capture has a linear relationship with CD64 expression indicating our approach can be used to measure CD64 expression based on total cell capture on Sepsis Chip. Our method has proven to be sensitive, accurate, rapid, and cost-effective. Therefore, this device is a promising detection platform for neutrophil activation and sepsis diagnosis.

  10. Postmortem memantine concentration in a non-intoxication case, and the possibility of postmortem redistribution: A case report.

    PubMed

    Nagasawa, Sayaka; Yajima, Daisuke; Torimitsu, Suguru; Chiba, Fumiko; Iwase, Hirotaro

    2015-12-01

    In this case study, we measured the concentration of memantine in the heart blood, peripheral blood, urine, liver, thigh muscle, and subcutaneous fat of a 64-year-old woman who was prescribed memantine for early-onset Alzheimer's disease. She died in hospital after an altercation with her husband. Cause of death was clearly not drug intoxication or overdose, so we investigated the postmortem redistribution (PMR) of memantine in the various tissues and blood ratios of the postmortem samples. Memantine concentrations detected were 1.31 μg/mL in the peripheral blood, 3.95 μg/mL in central blood, 2.09 μg/mL in the urine, 25.54 μg/g in the liver, 1.16 μg/g in the thigh muscle and 2.13 μg/g in the subcutaneous fat. In all samples, the concentrations were higher than the accepted therapeutic range (which is approximately 0.09-0.15 μg/mL). The central blood to peripheral blood (C/P) memantine ratio was 3.01 while the liver to peripheral blood (L/P) ratio was 19.5. It is documented that a C/P ratio exceeding 2 and L/P ratio exceeding 20 highlight a propensity for significant PMR. Although this is a single case study, our data suggest that memantine exhibits PMR. Additionally, a lowered pH was found in peripheral blood (pH 6.2) and central blood (pH 6.1). This postmortem reduction in blood pH may also promote the PMR of memantine. Because there is very little available postmortem toxicological data on memantine, our case study will serve as a foundation to assist in future forensic investigations. Copyright © 2015. Published by Elsevier Ireland Ltd.

  11. Performance Characteristics of Plasma Amyloid β 40 and 42 Assays

    PubMed Central

    Okereke, Olivia I.; Xia, Weiming; Irizarry, Michael C.; Sun, Xiaoyan; Qiu, Wei Q.; Fagan, Anne M.; Mehta, Pankaj D.; Hyman, Bradley T.; Selkoe, Dennis J.; Grodstein, Francine

    2009-01-01

    Background Identifying biomarkers of Alzheimer disease (AD) risk will be critical to effective AD prevention. Levels of circulating amyloid β (Aβ) 40 and 42 may be candidate biomarkers. However, properties of plasma Aβ assays must be established. Methods Using five different protocols, blinded samples were used to assess: intra-assay reproducibility; impact of EDTA vs. heparin anticoagulant tubes; and effect of time-to-blood processing. In addition, percent recovery of known Aβ concentrations in spiked samples was assessed. Results Median intra-assay coefficients of variation (CVs) for the assay protocols ranged from 6–24% for Aβ-40, and 8–14% for Aβ-42. There were no systematic differences in reproducibility by collection method. Plasma concentrations of Aβ (particularly Aβ-42) appeared stable in whole blood kept in ice packs and processed as long as 24 hours after collection. Recovery of expected concentrations was modest, ranging from -24% to 44% recovery of Aβ-40, and 17% to 61% of Aβ-42. Conclusions Across five protocols, plasma Aβ-40 and Aβ-42 levels were measured with generally low error, and measurements appeared similar in blood collected in EDTA vs. heparin. While these preliminary findings suggest that measuring plasma Aβ-40 and Aβ-42 may be feasible in varied research settings, additional work in this area is necessary. PMID:19221417

  12. Evaluation of a simple method for storage of blood samples that enables isolation of circulating tumor cells 96 h after sample collection.

    PubMed

    Apostolou, Panagiotis; Ntanovasilis, Dimitrios-Athanasios; Papasotiriou, Ioannis

    2017-12-01

    Minimizing the effects of transportation on the properties of biological material is a major challenge for the scientific community. The viability of cells is important in cases where their study is urgent for evaluation of treatment response or for the study of cancer progression. Circulating tumor cells (CTCs) constitute a cell subpopulation with great importance for oncologists, because of their prognostic value. Detection and isolation of CTCs from blood samples is a routine activity in many laboratories, but concerns exist with regard to the maintenance of the cells during transportation. In this study, experiments were conducted to determine the stability of gene and protein expression in CTCs over a period of 96 h. Blood samples collected from healthy individuals and patients with cancer were each divided into five aliquots, which were stored at 2-8 °C and analyzed after 0, 24, 48, 72 and 96 h of storage. CTCs from patients and CD45-negative cells from healthy individuals were isolated each day using enrichment protocols, and qPCR was performed to determine expression levels of genes encoding specific biological markers. In addition, cells from breast and colon cancer cell lines were spiked into blood samples from healthy individuals, and these samples were stored and analyzed over a period of 96 h by PCR and by flow cytometry. The markers that were studied included housekeeping genes and genes associated with the response to chemotherapy, as well as genes encoding transcription factors. The results demonstrated that the expression profiles of specific genes and proteins in CTCs were not significantly affected by 72 h of storage. After 96 h of storage, expression of some genes was altered. The transportation of blood at low temperature (2-8 °C) in the presence of the anticoagulant EDTA can protect CTCs from alteration of gene and protein expression for at least 72 h. Furthermore, under these conditions, CTCs can be detected and isolated 96 h after blood collection.

  13. Factors affecting Brucella spp. blood cultures positivity in children.

    PubMed

    Apa, Hurşit; Devrim, Ilker; Memur, Seyma; Günay, Ilker; Gülfidan, Gamze; Celegen, Mehmet; Bayram, Nuri; Karaarslan, Utku; Bağ, Ozlem; Işgüder, Rana; Oztürk, Aysel; Inan, Seyhan; Unal, Nurrettin

    2013-03-01

    Brucella infections have a wide spectrum of symptoms especially in children, making the diagnosis a complicated process. The gold standard for the final diagnosis for brucellosis is to identify the Brucella spp. isolated from blood or bone marrow cultures. The main purpose of this work was to evaluate the factors affecting the isolation of Brucella spp. from blood cultures. In our study, the ratio of fever, presence of hepatomegaly, and splenomegaly were found to be higher in the bacteremic group. In addition, C-reactive protein levels and liver function enzymes were found to be higher in the bacteremic group. In our opinion, while evaluating the febrile child with suspected Brucella infection, we highly recommend sampling blood cultures regardless of the history of previous antimicrobial therapy and duration of the symptoms.

  14. TH-C-18A-09: Exam and Patient Parameters Affecting the DNA Damage Response Following CT Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgart, S; Adibi, A; Bostani, M

    Purpose: To identify exam and patient parameters affecting the biological response to CT studies using in vivo and ex vivo blood samples. Methods: Blood samples were collected under IRB approval from 16 patients undergoing clinically-indicated CT exams. Blood was procured prior to, immediately after and 30minutes following irradiation. A sample of preexam blood was placed on the patient within the exam region for ex vivo analysis. Whole blood samples were fixed immediately following collection and stained for γH2AX to assess DNA damage response (DDR). Median fluorescence of treated samples was compared to non-irradiated control samples for each patient. Patients weremore » characterized by observed biological kinetic response: (a) fast — phosphorylation increased by 2minutes and fell by 30minutes, (b) slow — phosphorylation continued to increase to 30minutes and (c) none — little change was observed or irradiated samples fell below controls. Total dose values were normalized to exam time for an averaged dose-rate in dose/sec for each exam. Relationships between patient biological responses and patient and exam parameters were investigated. Results: A clearer dose response at 30minutes is observed for young patients (<61yoa; R2>0.5) compared to old patients (>61yoa; R{sup 2}<0.11). Fast responding patients were significantly younger than slow responding patients (p<0.05). Unlike in vivo samples, age did not significantly affect the patient response ex vivo. Additionally, fast responding patients received exams with significantly smaller dose-rate than slow responding patients (p<0.05). Conclusion: Age is a significant factor in the biological response suggesting that DDR may be more rapid in a younger population and slower as the population ages. Lack of an agerelated response ex vivo suggests a systemic response to radiation not present when irradiated outside the body. Dose-rate affects the biological response suggesting that patient response may be related to scan timing and dose delivery within an exam protocol. All authors receive(d) funding from a Master Research Agreement from Siemens Healthcare with UCLA Radiological Sciences.« less

  15. Trace elements in patients on continuous renal replacement therapy.

    PubMed

    Broman, M; Bryland, A; Carlsson, O

    2017-07-01

    Intensive care patients with acute kidney injury (AKI), treated with continuous renal replacement therapy (CRRT) are at great risk for disturbances in plasma levels of trace elements due to the underlying illness, AKI, and dialysis. This study was performed to increase our knowledge regarding eight different trace elements during CRRT. Thirty one stable patients with AKI, treated with CRRT, were included in the study. Blood, plasma and effluent samples were taken at the start of the study and 36 ± 12 h later. A group of 48 healthy volunteers were included as controls and exposed to one fasting blood sample. Samples were analysed for trace elements (Cr, Cu, Mn, Co, Zn, Rb, Mo, Se) and standard blood chemistry. Blood and plasma levels of selenium and rubidium were significantly reduced while the levels of chromium, cobalt, and molybdenum were significantly increased in the study group vs. healthy volunteers. There was an uptake of chromium, manganese, and zinc. Molybdenum mass balance was around zero. For selenium, copper, and rubidium there were a marked loss. The low levels of selenium and rubidium in blood and plasma from CRRT patients, together with the loss via CRRT effluent, raises the possibility of the need for selenium supplementation in this group of patients, despite the unchanged levels during the short study period. Further investigations on the effect of additional administration of trace elements to CRRT patients would be of interest. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Enhanced bactericidal activity against Escherichia coli in calves fed Morinda citrifolia (Noni) puree.

    PubMed

    Schäfer, M; Sharp, P; Brooks, V J; Xu, J; Cai, J; Keuler, N S; Peek, S F; Godbee, R G; Schultz, R D; Darien, B J

    2008-01-01

    Although adequate colostrum intake and properly used antibiotics can provide much protection for the bovine neonate, increased antibiotic scrutiny and consumer demand for organic products have prompted investigations of natural immunomodulators for enhancing calf health. One plant-based immunomodulator, Morinda citrifolia (noni) fruit, is a well-recognized natural product that has a broad range of immunomodulatory effects. Neonatal calves fed noni puree would demonstrate whole blood phagocytic capacity in Gram-negative and Gram-positive in vitro assays. Blood samples from 18 neonatal Holstein bull calves. Calves were divided into 2 groups: Group 1 comprised control calves, whereas Group 2 received 30 mL of noni puree twice a day in milk replacer. Day 0 blood samples were obtained between 36 and 48 hours of age before the first feeding of puree. Ethylenediaminetetraacetic acid anticoagulated blood was collected from each calf on days 0, 3, 7, and 14. Bactericidal assays were performed to estimate the percentage killing of Escherichia coli and Staphylococcus epidermidis. Blood samples from noni puree-fed calves displayed significantly more E. coli bacterial killing than did controls on day 14, and although differences were not significant on days 0, 3, and 7, bacterial killing progressively increased over time. There was no significant difference between the groups for S. epidermidis killing. The immunomodulatory effect of noni puree may prove valuable in the future as production animal antibiotic use becomes more restricted. Additional clinical trials are warranted to investigate the clinical application of noni puree in promoting calf health.

  17. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Detecting a wide range of environmental contaminants in human blood samples--combining QuEChERS with LC-MS and GC-MS methods.

    PubMed

    Plassmann, Merle M; Schmidt, Magdalena; Brack, Werner; Krauss, Martin

    2015-09-01

    Exposure to environmental pollution and consumer products may result in an uptake of chemicals into human tissues. Several studies have reported the presence of diverse environmental contaminants in human blood samples. However, previously developed multi-target methods for the analysis of human blood include a fairly limited amount of compounds stemming from one or two related compound groups. Thus, the sample preparation method QuEChERS (quick easy cheap effective rugged and safe) was tested for the extraction of 64 analytes covering a broad compound domain followed by detection using liquid and gas chromatography coupled to mass spectrometry (LC- and GC-MS). Forty-seven analytes showed absolute recoveries above 70% in the first QuEChERS step, being a simple liquid-liquid extraction (LLE) using acetonitrile and salt. The second QuEChERS step, being a dispersive solid phase extraction, did not result in an overall improvement of recoveries or removal of background signals. Using solely the LLE step, eight analytes could subsequently be detected in human blood samples from the German Environmental Specimen Bank. Using a LC-multiple reaction monitoring (MRM) method with a triple quadrupole instrument, better recoveries were achieved than with an older LC-high-resolution (HR) MS full scan orbitrap instrument, which required a higher concentration factor of the extracts. However, the application of HRMS full scan methods could be used for the detection of additional compounds retrospectively.

  19. Towards Clinical Applications of Blood-Borne miRNA Signatures: The Influence of the Anticoagulant EDTA on miRNA Abundance

    PubMed Central

    Leidinger, Petra; Backes, Christina; Rheinheimer, Stefanie; Keller, Andreas; Meese, Eckart

    2015-01-01

    Background Circulating microRNAs (miRNAs) from blood are increasingly recognized as biomarker candidates for human diseases. Clinical routine settings frequently include blood sampling in tubes with EDTA as anticoagulant without considering the influence of phlebotomy on the overall miRNA expression pattern. We collected blood samples from six healthy individuals each in an EDTA blood collection tube. Subsequently, the blood was transferred into PAXgeneTM tubes at three different time points, i.e. directly (0 min), 10 min, and 2 h after phlebotomy. As control blood was also directly collected in PAXgeneTM blood RNA tubes that contain a reagent to directly lyse blood cells and stabilize their content. For all six blood donors at the four conditions (24 samples) we analyzed the abundance of 1,205 miRNAs by human Agilent miRNA V16 microarrays. Results While we found generally a homogenous pattern of the miRNA abundance in all 24 samples, the duration of the EDTA treatment appears to influence the miRNA abundance of specific miRNAs. The most significant changes are observed after longer EDTA exposition. Overall, the impact of the different blood sample conditions on the miRNA pattern was substantially lower than intra-individual variations. While samples belonging to one of the six individuals mostly cluster together, there was no comparable clustering for any of the four tested blood sampling conditions. The most affected miRNA was miR-769-3p that was not detected in any of the six PAXgene blood samples, but in all EDTA 2h samples. Accordingly, hsa-miR-769-3p was also the only miRNA that showed a significantly different abundance between the 4 blood sample conditions by an ANOVA analysis (Benjamini-Hochberg adjusted p-value of 0.003). Validation by qRT-PCR confirmed this finding. Conclusion The pattern of blood-borne miRNA abundance is rather homogenous between the four tested blood sample conditions of six blood donors. There was a clustering between the miRNA profiles that belong to a specific blood donor, but not between any of the four tested blood sampling conditions. The results show a limited overall impact of the blood sampling conditions on the miRNA pattern. Notwithstanding, the abundance of single miRNAs can be significantly altered by different blood sampling conditions. PMID:26599228

  20. Factors affecting a cyanogen bromide-based assay of thiamin.

    PubMed

    Wyatt, D T; Lee, M; Hillman, R E

    1989-11-01

    We analyzed extensively a modified thiochrome method for thiamin analysis. Acid phosphatase (EC 3.1.3.2) from potato was superior to either alpha-amylase or acid phosphatase from wheat germ as a dephosphorylating agent. Timing of cyanogen bromide exposure was important, but the assay had good precision and accuracy. The standard curve was linear from 10 to 3000 nmol/L. The within-run and between-run coefficients of variation for total thiamin in whole blood were 3.6% and 7.4%, respectively. Analytical recoveries for low, intermediate, and high additions of thiamin to whole blood were 93-109%. Sample yield was increased by 41% (+/- 29% SD) with pre-assay freezing. Samples were stable for two days at room temperature, for seven days when refrigerated, and for two years when frozen. Previously unreported interference was seen with penicillin derivatives, and with several commonly used diuretic and antiepileptic medications. This assay may be suitable for population screening; 200 samples could be analyzed weekly at a cost of +0.20 per sample.

  1. CGG allele size somatic mosaicism and methylation in FMR1 premutation alleles

    PubMed Central

    Pretto, Dalyir I.; Mendoza-Morales, Guadalupe; Lo, Joyce; Cao, Ru; Hadd, Andrew; Latham, Gary J.; Durbin-Johnson, Blythe; Hagerman, Randi; Tassone, Flora

    2014-01-01

    Background Greater than 200 CGG repeats in the 5′UTR of the FMR1 gene leads to epigenetic silencing and lack of the FMR1 protein, causing Fragile X Syndrome. Individuals carriers of a premutation (PM) allele with 55–200 CGG repeats are typically unmethylated and can present with clinical features defined as FMR1 associated conditions. Methods Blood samples from 17 male PM carriers were assessed clinically and molecularly by Southern Blot, Western Blot, PCR and QRT-PCR. Blood and brain tissue from additional 18 PM males were also similarly examined. Continuous outcomes were modeled using linear regression and binary outcomes were modeled using logistic regression. Results Methylated alleles were detected in different fractions of blood cells in all PM cases (n= 17). CGG repeat numbers correlated with percent of methylation and mRNA levels and, especially in the upper PM range, with greater number of clinical involvements. Inter/intra- tissue somatic instability and differences in percent methylation were observed between blood and fibroblasts (n=4) and also observed between blood and different brain regions in three of the 18 premutation cases examined. CGG repeat lengths in lymphocytes remained unchanged over a period of time ranging from 2–6 years, three cases for whom multiple samples were available. Conclusion In addition to CGG size instability, individuals with a PM expanded alleles can exhibit methylation and display more clinical features likely due to RNA toxicity and/or FMR1 silencing. The observed association between CGG repeat length and percent of methylation with the severity of the clinical phenotypes underscores the potential value of methylation in affected PM to further understand penetrance, inform diagnosis and to expand treatment options. PMID:24591415

  2. Forensic SNP Genotyping with SNaPshot: Development of a Novel In-house SBE Multiplex SNP Assay.

    PubMed

    Zar, Mian Sahib; Shahid, Ahmad Ali; Shahzad, Muhammad Saqib; Shin, Kyoung-Jin; Lee, Hwan Young; Lee, Sang-Seob; Israr, Muhammad; Wiegand, Peter; Kulstein, Galina

    2018-04-10

    This study introduces a newly developed in-house SNaPshot single-base extension (SBE) multiplex assay for forensic single nucleotide polymorphism (SNP) genotyping of fresh and degraded samples. The assay was validated with fresh blood samples from four different populations. In addition, altogether 24 samples from skeletal remains were analyzed with the multiplex. Full SNP profiles could be obtained from 14 specimens, while ten remains showed partial SNP profiles. Minor allele frequencies (MAF) of bone samples and different populations were compared and used for association of skeletal remains with a certain population. The results reveal that the SNPs of the bone samples are genetically close to the Pathan population. The findings show that the new multiplex system can be utilized for SNP genotyping of degraded and forensic relevant skeletal material, enabling to provide additional investigative leads in criminal cases. © 2018 American Academy of Forensic Sciences.

  3. Factors affecting blood sample haemolysis: a cross-sectional study.

    PubMed

    Barnard, Ed B G; Potter, David L; Ayling, Ruth M; Higginson, Ian; Bailey, Andrew G; Smith, Jason E

    2016-04-01

    To determine the effect of blood sampling through an intravenous catheter compared with a needle in Emergency Department blood sampling. We undertook a prospective, cross-sectional study in a UK university teaching hospital Emergency Department. A convenience sample of 985 patients who required blood sampling via venepuncture was collected. A total of 844 complete sets of data were analysed. The median age was 63 years, and 57% of patients were male. The primary outcome measure was the incidence of haemolysis in blood samples obtained via a needle compared with samples obtained via an intravenous catheter. Secondary outcome measures defined the effect on sample haemolysis of the side of the patient the sample was obtained from, the anatomical location of sampling, the perceived difficulty in obtaining the sample, the order of sample tubes collected, estimated tourniquet time and bench time. Data were analysed with logistic regression, and expressed as odds ratios (95% confidence intervals; P-values). Blood samples obtained through an intravenous catheter were more likely to be haemolysed than those obtained via a needle, odds ratio 5.63 (95% confidence interval 2.49-12.73; P<0.001). Blood sampling via an intravenous catheter was significantly associated with an increase in the likelihood of sample haemolysis compared with sampling with a needle. Wherever practicable, blood samples should be obtained via a needle in preference to an intravenous catheter. Future research should include both an economic evaluation, and staff and patient satisfaction of separating blood sampling and intravenous catheter placement.

  4. Seroprevalence for hepatitis E virus (HEV) infection among volunteer blood donors of the Regional Blood Bank of Londrina, State of Paraná , Brazil.

    PubMed

    Bortoliero, André Luiz; Bonametti, Ana Maria; Morimoto, Helena Kaminami; Matsuo, Tiemi; Reiche, Edna Maria Vissoci

    2006-01-01

    A cross-sectional study was carried out among 996 volunteer blood donors enrolled from May 1999 to December 1999 to determine the seroprevalence of hepatitis E virus (HEV) infection among volunteer blood donors of the Regional Blood Bank of Londrina, State of Paraná, Brazil, and to evaluate whether the rate of seroprevalence of IgG anti-HEV antibodies is associated with sociodemographic variables and with seropositivity for hepatitis A virus (HAV) infection. All participants answered the questionnaire regarding the sociodemographic characteristics. Serum samples were tested for IgG antibodies to HEV (anti-HEV) by an enzyme linked immunoassay (ELISA). All serum samples positive for anti-HEV IgG and 237 serum samples negative for anti-HEV were also assayed for IgG anti-HAV antibodies by ELISA. Anti-HEV IgG was confirmed in 23/996 samples, resulting in a seroprevalence of 2.3% for HEV infection, similar to previous results obtained in developed countries. No significant association was found between the presence of anti-HEV IgG antibodies and the sociodemographic variables including gender, age, educational level, rural or urban areas, source of water, and sewer system (p > 0.05). Also, no association with seropositivity for anti-HAV IgG antibodies was observed (p > 0.05). Although this study revealed a low seroprevalence of HEV infection in the population evaluated, the results showed that this virus is circulating among the population from Londrina, South Brazil, and point out the need of further studies to define the clinical and epidemiological importance of HEV infection and to identify additional risk factors involved in the epidemiology and pathogenesis of this infection in this population.

  5. Assessing errors in the determination of base excess.

    PubMed

    Mentel, Alexander; Bach, Friedhelm; Schüler, Joerg; Herrmann, Walter; Koster, Andreas; Crystal, George J; Gatzounis, Georgios; Mertzlufft, Fritz

    2002-05-01

    We compared estimates for base excess of extracellular fluid (BE(ecf); mmol/L) obtained in five clinically used blood gas analyzers: AVL Compact 2 (Roche Diagnostics, Mannheim, Germany), Ciba-Corning 860 (Bayer Diagnostics, Fernwald, Germany), IL 1620 (Instrumentation Laboratories, Lexington, MA), Stat Profile Ultra (Nova Biomedical, Waltham, MA), and ABL 510 (Radiometer, Copenhagen, Denmark). A total of 134 measurements per analyzer were obtained in arterial and venous blood samples from 10 patients undergoing cardiac surgery and 65 measurements per analyzer in venous blood samples from 2 healthy volunteers. The blood samples were equilibrated in a tonometer with gases of known composition (37 degrees C). Additional theoretical studies were performed to evaluate the relationship between pH and calculated BE(ecf) value (with varied PCO(2)) using the formulas of the various analyzers. The standard deviations of repeated measurements were 0.24 mmol/L for ABL 510 and approximately 0.45 mmol/L for the other 4 analyzers. The maximal systematic difference between the average of all measurements of each analyzer was 3.7 mmol/L; this was primarily attributable to differences in measuring pH, and, to a lesser extent, to differences in calculation and determination of PCO(2). Comparison of the results from samples with different oxygen saturation showed that the relative alkalinity of deoxygenated hemoglobin (Haldane effect) can also influence the determinations of BE(ecf). A clinically useful way to quantify nonrespiratory disturbances of the acid-base balance is calculation of the base excess of extracellular fluid by using blood gas analyzers. In this study, we found significant variability in estimates of base excess of extracellular fluid obtained with five analyzers from different manufacturers. This variability is attributable to multiple factors, including lack of correction for deoxygenated hemoglobin (Haldane effect).

  6. Deproteinization assessment using isotopically enriched compounds to trace the coprecipitation of low-molecular-weight selenium species with proteins.

    PubMed

    Godin, Simon; Bouzas-Ramos, Diego; Fontagné-Dicharry, Stéphanie; Bouyssière, Brice; Bueno, Maïté

    2017-08-01

    Studies have shown that information related to the presence of low-molecular-weight metabolites is frequently lost after deproteinization of complex matrices, such as blood and plasma, during sample preparation. Therefore, the effect of several deproteinization reagents on low-molecular-weight selenium species has been compared by species-specific isotope labeling. Two isotopically enriched selenium tracers were used to mimic models of small inorganic anionic ( 77 Se-selenite) and organic zwitterionic ( 76 Se-selenomethionine) species. The results presented here show that the use of a methanol-acetonitrile-acetone (1:1:1 v/v/v) mixture provided approximately two times less tracer loss from plasma samples in comparison with the classic procedure using acetonitrile, which may not be optimal as it leads to important losses of low-molecular-weight selenium species. In addition, the possible interactions between selenium tracers and proteins were investigated, revealing that both coprecipitation phenomena and association with proteins were potentially responsible for selenite tracer losses during protein precipitation in blood samples. However, coprecipitation phenomena were found to be fully responsible for losses of both tracers observed in plasma samples and of the selenomethionine tracer in blood samples. This successfully applied strategy is anticipated to be useful for more extensive future studies in selenometabolomics. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. LPS-induced microvascular leukocytosis can be assessed by blue-field entoptic phenomenon.

    PubMed

    Kolodjaschna, Julia; Berisha, Fatmire; Lung, Solveig; Schaller, Georg; Polska, Elzbieta; Jilma, Bernd; Wolzt, Michael; Schmetterer, Leopold

    2004-08-01

    Administration of low doses of Escherichia coli endotoxin [a lipopolysaccharide (LPS)] to humans enables the study of inflammatory mechanisms. The purpose of the present study was to investigate whether the blue-field entoptic technique may be used to quantify the increase in circulating leukocytes in the ocular microvasculature after LPS infusion. In addition, combined laser Doppler velocimetry and retinal vessel size measurement were used to study red blood cell movement. Twelve healthy male volunteers received 20 IU/kg iv LPS as a bolus infusion. Outcome parameters were measured at baseline and 4 h after LPS administration. In the first protocol (n = 6 subjects), ocular hemodynamic effects were assessed with the blue-field entoptic technique, the retinal vessel analyzer, and laser Doppler velocimetry. In the second protocol (n = 6 subjects), white blood cell (WBC) counts from peripheral blood samples and blue-field entoptic technique measurements were performed. LPS caused peripheral blood leukocytosis and increased WBC density in ocular microvessels (by 49%; P = 0.036) but did not change WBC velocity. In addition, retinal venous diameter was increased (by 9%; P = 0.008), but red blood cell velocity remained unchanged. The LPS-induced changes in retinal WBC density and leukocyte counts were significantly correlated (r = 0.87). The present study indicates that the blue-field entoptic technique can be used to assess microvascular leukocyte recruitment in vivo. In addition, our data indicate retinal venous dilation in response to endotoxin.

  8. Omega-3 polyunsaturated fatty acid blood biomarkers increase linearly in men and women after tightly controlled intakes of 0.25, 0.5, and 1 g/d of EPA + DHA.

    PubMed

    Patterson, Ashley C; Chalil, Alan; Aristizabal Henao, Juan J; Streit, Isaac T; Stark, Ken D

    2015-12-01

    Blood levels of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) have been related to coronary heart disease risk. Understanding the response of EPA + DHA in blood to dietary intake of EPA + DHA would facilitate the use of blood measures as markers of adherence and enable the development of dietary recommendations. The objective of this study is examine the blood response to intakes of EPA + DHA ≤1 g/d with an intervention designed for dietary adherence. It was hypothesized this relationship would be linear and that intakes of EPA + DHA <1 g/d would result in blood levels below those associated with the highest level of protection for cardiovascular events. Background EPA + DHA intake of men and women (n = 20) was determined by food frequency questionnaire and adherence was monitored by weekly fingertip blood sampling for fatty acid determinations. Participants consumed nutraceuticals to achieve intakes of 0.25 g/d and 0.5 g/d EPA + DHA for successive four-week periods. A subgroup (n = 5) had intakes of 1.0 g/d EPA + DHA for an additional 4 weeks. Fatty acid composition of whole blood, erythrocytes, and plasma phospholipids were determined at each time point. Blood levels of EPA and DHA increased linearly in these pools. A comprehensive review of the literature was used to verify the blood-intake relationship. Blood levels of long chain omega-3 polyunsaturated fatty acids reached blood levels associated with the highest levels of primary cardiac arrest reduction and sudden cardiac death risk only with intakes of 1.0 g/d of EPA + DHA. The blood biomarker response to intakes of EPA + DHA ≤1 g/d is linear in a small but highly adherent study sample and this information can assist in determining adherence in clinical studies and help identify dietary intake targets from associations between blood and disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Determination of proflavine in rat whole blood without sample pretreatment by laser desorption postionization mass spectrometry.

    PubMed

    Chen, Jiaxin; Hu, Yongjun; Lu, Qiao; Wang, Pengchao; Zhan, Huaqi

    2017-04-01

    A novel pretreatment-free method involving laser desorption postionization (LDPI) coupled with time-of-flight mass spectrometry (MS) was developed for the monitoring of proflavine level in rat whole blood. It comprises a protocol for dosing via intravenous administration and collection of whole blood, followed by direct LDPI-MS analysis without any sample pretreatment. An intense ion signal at m/z 209 was observed from whole blood without any interference signals, except some background signals below m/z 100. The calibration curve was established with use of 9-phenylacridine as the internal standard for proflavine determination from the plotting of the peak ratios of proflavine to the internal standard, with a correlation coefficient (R 2 ) greater than 0.99. The limit of detection was estimated to be 0.48 pmol/mm 2 and the quantification range was 0.5-16.5 μg/mL for proflavine. In addition, only a minimal matrix effect was observed, as expected from considerations of the desorption and ionization mechanism. Interday and intraday accuracy and precision were calculated to be within 13% and 82-114%, respectively. Estimated concentrations of proflavine residue in whole blood were also successfully obtained at selected time points after dosing. The proposed method is simple, low cost, and sensitive, and should be seen as a complementary method for monitoring drug levels in blood. Graphical Abstract Monitoring proflavine levels in rat whole blood at different time points using laser desorption postionization mass spectrometry (LDPI-MS).

  10. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    PubMed

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  11. Performance testing of a semi-automatic card punch system, using direct STR profiling of DNA from blood samples on FTA™ cards.

    PubMed

    Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J

    2015-01-01

    The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.

  12. Aging: a portrait from gene expression profile in blood cells.

    PubMed

    Calabria, Elisa; Mazza, Emilia Maria Cristina; Dyar, Kenneth Allen; Pogliaghi, Silvia; Bruseghini, Paolo; Morandi, Carlo; Salvagno, Gian Luca; Gelati, Matteo; Guidi, Gian Cesare; Bicciato, Silvio; Schiaffino, Stefano; Schena, Federico; Capelli, Carlo

    2016-08-01

    The availability of reliable biomarkers of aging is important not only to monitor the effect of interventions and predict the timing of pathologies associated with aging but also to understand the mechanisms and devise appropriate countermeasures. Blood cells provide an easily available tissue and gene expression profiles from whole blood samples appear to mirror disease states and some aspects of the aging process itself. We report here a microarray analysis of whole blood samples from two cohorts of healthy adult and elderly subjects, aged 43±3 and 68±4 years, respectively, to monitor gene expression changes in the initial phase of the senescence process. A number of significant changes were found in the elderly compared to the adult group, including decreased levels of transcripts coding for components of the mitochondrial respiratory chain, which correlate with a parallel decline in the maximum rate of oxygen consumption (VO2max), as monitored in the same subjects. In addition, blood cells show age-related changes in the expression of several markers of immunosenescence, inflammation and oxidative stress. These findings support the notion that the immune system has a major role in tissue homeostasis and repair, which appears to be impaired since early stages of the aging process.

  13. Mineral elements and essential trace elements in blood of seals of the North Sea measured by total-reflection X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Griesel, S.; Mundry, R.; Kakuschke, A.; Fonfara, S.; Siebert, U.; Prange, A.

    2006-11-01

    Mineral and essential trace elements are involved in numerous physiological processes in mammals. Often, diseases are associated with an imbalance of the electrolyte homeostasis. In this study, the concentrations of mineral elements (P, S, K, Ca) and essential trace elements (Fe, Cu, Zn, Se, Rb, Sr) in whole blood of harbor seals ( Phoca vitulina) were determined using total-reflection X-ray fluorescence spectrometry (TXRF). Samples from 81 free-ranging harbor seals from the North Sea and two captive seals were collected during 2003-2005. Reference ranges and element correlations for health status determination were derived for P, S, K, Ca, Fe, Cu, and Zn level in whole blood. Grouping the seals by age, gender and sample location the concentration levels of the elements were compared. The blood from two captive seals with signs of diseases and four free-ranging seals showed reduced element levels of P, S, and Ca and differences in element correlation of electrolytes were ascertained. Thus, simultaneous measurements of several elements in only 500 μL volumes of whole blood provide the possibility to obtain information on both, the electrolyte balance and the hydration status of the seals. The method could therefore serve as an additional biomonitoring tool for the health assessment.

  14. The impact of lymphocyte isolation on induced DNA damage in human blood samples measured by the comet assay.

    PubMed

    Bausinger, Julia; Speit, Günter

    2016-09-01

    The comet assay is frequently used in human biomonitoring for the detection of exposure to genotoxic agents. Peripheral blood samples are most frequently used and tested either as whole blood or after isolation of lymphocytes (i.e. peripheral blood mononuclear cells, PBMC). To investigate a potential impact of lymphocyte isolation on induced DNA damage in human blood samples, we exposed blood ex vivo to mutagens with different modes of genotoxic action. The comet assay was performed either directly with whole blood at the end of the exposure period or with lymphocytes isolated directly after exposure. In addition to the recommended standard protocol for lymphocyte isolation, a shortened protocol was established to optimise the isolation procedure. The results indicate that the effects of induced DNA strand breaks and alkali-labile sites induced by ionising radiation and alkylants, respectively, are significantly reduced in isolated lymphocytes. In contrast, oxidative DNA base damage (induced by potassium bromate) and stable bulky adducts (induced by benzo[a]pyrene-7,8-dihydrodiol-9,10-epoxide; BPDE) seem to be less affected. Our findings suggest that in vivo-induced DNA damage might also be reduced in isolated lymphocytes in comparison with the whole blood depending of the types of DNA damage induced. Because only small genotoxic effects can generally be expected in human biomonitoring studies with the comet assay after occupational and environmental exposure to genotoxic agents, any loss might be relevant and should be avoided. The possibility of such effects and their potential impact on variability of comet assay results in human biomonitoring should be considered when performing or evaluating such kind of studies. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Methods of blood flow measurement in the arterial circulatory system.

    PubMed

    Tabrizchi, R; Pugsley, M K

    2000-01-01

    The most commonly employed techniques for the in vivo measurement of arterial blood flow to individual organs involve the use of flow probes or sensors. Commercially available systems for the measurement of in vivo blood flow can be divided into two categories: ultrasonic and electromagnetic. Two types of ultrasonic probes are used. The first type of flow probe measures blood flow-mediated Doppler shifts (Doppler flowmetry) in a vessel. The second type of flow probe measures the "transit time" required by an emitted ultrasound wave to traverse the vessel and are transit-time volume flow sensors. Measurement of blood flow in any vessel requires that the flow probe or sensor be highly accurate and exhibit signal linearity over the flow range in the vessel of interest. Moreover, additional desirable features include compact design, size, and weight. An additional important feature for flow probes is that they exhibit good biocompatability; it is imperative for the sensor to behave in an inert manner towards the biological system. A sensitive and reliable method to assess blood flow in individual organs in the body, other than by the use of probes/sensors, is the reference sample method that utilizes hematogeneously delivered microspheres. This method has been utilized to a large extend to assess regional blood flow in the entire body. Obviously, the purpose of measuring blood flow is to determine the amount of blood delivered to a given region per unit time (milliliters per minute) and it is desirable to achieve this goal by noninvasive methodologies. This, however, is not always possible. This review attempts to offer an overview of some of the techniques available for the assessment of regional blood flow in the arterial circulatory system and discusses advantages and disadvantages of these common techniques.

  16. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow.

    PubMed

    Volani, Chiara; Caprioli, Giulia; Calderisi, Giovanni; Sigurdsson, Baldur B; Rainer, Johannes; Gentilini, Ivo; Hicks, Andrew A; Pramstaller, Peter P; Weiss, Guenter; Smarason, Sigurdur V; Paglia, Giuseppe

    2017-10-01

    Volumetric absorptive microsampling (VAMS) is a novel approach that allows single-drop (10 μL) blood collection. Integration of VAMS with mass spectrometry (MS)-based untargeted metabolomics is an attractive solution for both human and animal studies. However, to boost the use of VAMS in metabolomics, key pre-analytical questions need to be addressed. Therefore, in this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. We first evaluated the best extraction procedure for the polar metabolome and found that the highest number and amount of metabolites were recovered upon extraction with acetonitrile/water (70:30). In contrast, basic conditions (pH 9) resulted in divergent metabolite profiles mainly resulting from the extraction of intracellular metabolites originating from red blood cells. In addition, the prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but once the VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months. The time used for drying the sample did also affect the metabolome. In fact, some metabolites were rapidly degraded or accumulated in the sample during the first 48 h at room temperature, indicating that a longer drying step will significantly change the concentration in the sample. Graphical abstract Volumetric absorptive microsampling (VAMS) is a novel technology that allows single-drop blood collection and, in combination with mass spectrometry (MS)-based untargeted metabolomics, represents an attractive solution for both human and animal studies. In this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. The latter revealed that prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but if VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months.

  17. Detection of Angiostrongylus cantonensis in the Blood and Peripheral Tissues of Wild Hawaiian Rats (Rattus rattus) by a Quantitative PCR (qPCR) Assay.

    PubMed

    Jarvi, Susan I; Pitt, William C; Farias, Margaret E; Shiels, Laura; Severino, Michael G; Howe, Kathleen M; Jacquier, Steven H; Shiels, Aaron B; Amano, Karis K; Luiz, Blaine C; Maher, Daisy E; Allison, Maureen L; Holtquist, Zachariah C; Scheibelhut, Neil T

    2015-01-01

    The nematode Angiostrongylus cantonensis is a rat lungworm, a zoonotic pathogen that causes human eosinophilic meningitis and ocular angiostrongyliasis characteristic of rat lungworm (RLW) disease. Definitive diagnosis is made by finding and identifying A. cantonensis larvae in the cerebral spinal fluid or by using a custom immunological or molecular test. This study was conducted to determine if genomic DNA from A. cantonensis is detectable by qPCR in the blood or tissues of experimentally infected rats. F1 offspring from wild rats were subjected to experimental infection with RLW larvae isolated from slugs, then blood or tissue samples were collected over multiple time points. Blood samples were collected from 21 rats throughout the course of two trials (15 rats in Trial I, and 6 rats in Trial II). In addition to a control group, each trial had two treatment groups: the rats in the low dose (LD) group were infected by approximately 10 larvae and the rats in the high dose (HD) group were infected with approximately 50 larvae. In Trial I, parasite DNA was detected in cardiac bleed samples from five of five LD rats and five of five HD rats at six weeks post-infection (PI), and three of five LD rats and five of five HD rats from tail tissue. In Trial II, parasite DNA was detected in peripheral blood samples from one of two HD rats at 53 minutes PI, one of two LD rats at 1.5 hours PI, one of two HD rats at 18 hours PI, one of two LD rats at five weeks PI and two of two at six weeks PI, and two of two HD rats at weeks five and six PI. These data demonstrate that parasite DNA can be detected in peripheral blood at various time points throughout RLW infection in rats.

  18. [Occupational exposure to methyl tert-butyl ether (MTBE) at an oil refinery].

    PubMed

    Perbellini, L; Pasini, F; Prigioni, P; Rosina, A

    2003-01-01

    Methyl tert-butyl ether (MTBE) is widely used as an additive to gasoline, to increase oxygen content and reduce tailpipe emission of carbon monoxide. Our research dealt with 37 refinery workers in order to measure their occupational exposure to MTBE during two different seasonal periods. They provided blood and urine samples before and after a work shift during which they wore an active charcoal sampler for solvents. All samples were analysed by a gas-chromatograph equipped with a mass spectrometer detector. The concentration in air of MTBE was very low (median: 25 micrograms/m3 in spring and 5 micrograms/m3 in autumn). The blood and urine concentrations of MTBE at the end of the work shift were higher than those found before the shift. The increment in biological samples confirmed a small intake of MTBE by refinery workers: the biological monitoring of occupational exposure to this solvent yielded reliable results. Blood and urinary concentrations of MTBE obtained from workers split in relation to their smoking habit did not give a statistic significance to say that cigarette smoke is not a confusion factor in monitoring exposure to MTBE.

  19. Dosimetric and microdosimetric analyses for blood exposed to reactor-derived thermal neutrons.

    PubMed

    Ali, F; Atanackovic, J; Boyer, C; Festarini, A; Kildea, J; Paterson, L C; Rogge, R; Stuart, M; Richardson, R B

    2018-06-06

    Thermal neutrons are found in reactor, radiotherapy, aircraft, and space environments. The purpose of this study was to characterise the dosimetry and microdosimetry of thermal neutron exposures, using three simulation codes, as a precursor to quantitative radiobiological studies using blood samples. An irradiation line was designed employing a pyrolytic graphite crystal or-alternatively-a super mirror to expose blood samples to thermal neutrons from the National Research Universal reactor to determine radiobiological parameters. The crystal was used when assessing the relative biological effectiveness for dicentric chromosome aberrations, and other biomarkers, in lymphocytes over a low absorbed dose range of 1.2-14 mGy. Higher exposures using a super mirror will allow the additional quantification of mitochondrial responses. The physical size of the thermal neutron fields and their respective wavelength distribution was determined using the McStas Monte Carlo code. Spinning the blood samples produced a spatially uniform absorbed dose as determined from Monte Carlo N-Particle version 6 simulations. The major part (71%) of the total absorbed dose to blood was determined to be from the 14 N(n,p) 14 C reaction and the remainder from the 1 H(n,γ) 2 H reaction. Previous radiobiological experiments at Canadian Nuclear Laboratories involving thermal neutron irradiation of blood yielded a relative biological effectiveness of 26 ± 7. Using the Particle and Heavy Ion Transport Code System, a similar value of ∼19 for the quality factor of thermal neutrons initiating the 14 N(n,p) 14 C reaction in soft tissue was determined by microdosimetric simulations. This calculated quality factor is of similar high value to the experimentally-derived relative biological effectiveness, and indicates the potential of thermal neutrons to induce deleterious health effects in superficial organs such as cataracts of the eye lens.

  20. Multiresidue analytical method using dispersive solid-phase extraction and gas chromatography/ion trap mass spectrometry to determine pharmaceuticals in whole blood.

    PubMed

    Plössl, Florian; Giera, Martin; Bracher, Franz

    2006-11-24

    A convenient analytical method for the simultaneous determination of more than 40 pharmaceuticals belonging to various therapeutic categories in whole blood has been developed. Exemplarily, the method was fully validated for eight different pharmaceuticals. The procedure entails addition of acetonitrile, magnesium sulfate and sodium chloride to a small amount of blood, then the mixture is shaken intensively and centrifuged for phase separation. An aliquot of the organic layer is cleaned up by dispersive solid-phase extraction employing bulk sorbents as well as magnesium sulfate for the removal of residual water. This method was based on the QuEChERS approach developed for pesticide residue analysis in food. Gas chromatography/ion trap mass spectrometry (GC/MS) with electron (EI) and chemical (CI) ionisation was then used for qualitative and quantitative determination of the pharmaceuticals. The dispersive SPE with PSA (sorbent functionalized with primary and secondary amines) was found more suitable than aminopropyl and a styrene-divinylbenzene sorbent for sample clean-up before drug level determination in whole blood and plasma, as it was found that most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 80%. Variation coefficients of the repeatability typically smaller than 10% have been achieved for a wide range of the investigated substances. The used analytical conditions allowed to separate successively a variety of drugs and poisons with the typical limit of detection at <20 ng mL(-1) levels using 1 microL injection of equivalent blood sample in whole blood. The method is simple, rapid, cheap and very effective for therapeutic drug monitoring and forensic chemistry.

  1. A uniform method for the simultaneous blood group phenotyping of Fya , Fyb , Jka , Jkb , S, s̅, P1, k applying lateral-flow technique.

    PubMed

    Caesar, A; Meyer, S; Trost, N; Neuenschwander, K; Geisen, C; Frey, B M; Gassner, C; Schwind, P

    2018-02-01

    A lateral flow assay for simultaneous blood group typing of ABO, RhD, C, E, c, e, Cw and K with stable end-point and without centrifugation is in routine use since several years (MDmulticard ® ). The typing of extended phenotype parameters belonging to the Duffy, Kidd, MNSs blood group systems and others, however, has not yet been demonstrated for this technique. Reliable detection of Fy x , a weak Fy b phenotype with a pronounced quantitative reduction of the number of Fy b antigens on the erythrocyte surface, remains a weakness of current serological blood grouping techniques. The performance characteristics of the following reagents were evaluated in donor and patient samples in lateral flow technology (MDmulticard ® ): Anti-Fy a , -Fy b , -Jk a , -Jk b , -S, -s̅, -P1 and -k. The sensitivity to detect Fy x was in addition evaluated with Fy x positive samples, which had been preselected by MALDI-TOF MS-based genotyping. All results obtained with the MDmulticard ® were in full accordance with those of the CE-certified reference products for all the eight reagent formulations used: Anti-Fy a , -Fy b , -Jk a , -Jk b , -S, -s̅, -P1 and -k. Also, all Fy x phenotypes of the selected population of 93 positive samples, originally identified by MALDI-TOF MS-based genotyping, were reliably detected by the lateral flow assay. Extended phenotype blood group parameters, including the serologically challenging Fy x phenotype, can be determined simultaneously, rapidly and accurately using the lateral flow (MDmulticard ® ) technology, even in cases when IgG class antibodies are the only source of diagnostic antibodies. © 2017 International Society of Blood Transfusion.

  2. Decrease in Ionized and Total Magnesium Blood Concentrations in Endurance Athletes Following an Exercise Bout Restores within Hours-Potential Consequences for Monitoring and Supplementation.

    PubMed

    Terink, Rieneke; Balvers, Michiel G J; Hopman, Maria T; Witkamp, Renger F; Mensink, Marco; Gunnewiek, Jacqueline M T Klein

    2017-06-01

    Magnesium is essential for optimal sport performance, generating an interest to monitor its status in athletes. However, before measuring magnesium status in blood could become routine, more insight into its diurnal fluctuations and effects of exercise itself is necessary. Therefore, we measured the effect of an acute bout of exercise on ionized (iMg) and total plasma magnesium (tMg) in blood obtained from 18 healthy well-trained endurance athletes (age, 31.1 ± 8.1 yr.; VO 2max , 50.9 ± 7.5 ml/kg/min) at multiple time points, and compared this with a resting situation. At both days, 7 blood samples were taken at set time points (8:30 fasted, 11:00, 12:30, 13:30, 15:00, 16:00, 18:30). The control day was included to correct for a putative diurnal fluctuation of magnesium. During the exercise day, athletes performed a 90 min bicycle ergometer test (70% VO 2max ) between 11:00 and 12:30. Whole blood samples were analyzed for iMg and plasma for tMg concentrations. Both concentrations decreased significantly after exercise (0.52 ± 0.04-0.45 ± 0.03 mmol/L and 0.81 ± 0.07-0.73 ± 0.06 mmol/L, respectively, p < .001) while no significant decline was observed during that time-interval on control days. Both, iMg and tMg, returned to baseline, on average, 2.5 hr after exercise. These findings suggest that timing of blood sampling to analyze Mg status is important. Additional research is needed to establish the recovery time after different types of exercise to come to a general advice regarding the timing of magnesium status assessment in practice.

  3. Effect of additive solutions on red blood cell (RBC) membrane properties of stored RBCs prepared from whole blood held for 24 hours at room temperature.

    PubMed

    Veale, Margaret F; Healey, Gerry; Sparrow, Rosemary L

    2011-01-01

    The quality of RBC components is influenced by collection, processing and storage conditions. Regulations require that whole blood (WB) units be refrigerated within 8 hours and processed into RBCs within 24 hours of collection. Overnight room temperature hold of WB has logistical advantages, but the effect on RBC quality has not been fully investigated. RBC additive solutions were compared for their ability to provide improved quality of RBCs prepared from WB held at room temperature for 24 hours. Leukocyte-reduced RBCs were prepared from WB held at 20°C on cooling plates for 24 hours prior to processing. RBCs were stored in additive solutions, SAG-M (control), Erythrosol-4, and PAGGSM, under standard blood banking conditions and sampled during 49 days of storage. Stored RBCs were evaluated for RBC shape and microparticle (MP) accumulation using flow cytometry. Osmotic fragility, adhesion of RBCs to endothelium under shear stress conditions (0.5 dyne/cm(2) ), and routine RBC quality parameters were assessed. RBCs stored in Erythrosol-4 and PAGGSM had decreased cell size, reduced osmotic fragility, and decreased accumulation of glycophorin A-positive MPs and annexin V-binding MPs compared with RBCs stored in SAG-M. RBCs stored in erythrosol-4 had increased adherence to endothelium at days 42 and 49 compared with RBCs stored in SAG-M or PAGGSM. RBCs stored in PAGGSM or Erythrosol-4 had improved retention of RBC membrane and osmotic resilience. The development of new additive solutions may offer improved quality of RBC components prepared from WB held overnight at room temperature. © 2010 American Association of Blood Banks.

  4. Immunocapture and microplate-based activity and quantity measurement of pyruvate dehydrogenase in human peripheral blood mononuclear cells.

    PubMed

    Liu, Xiaowen; Pervez, Hira; Andersen, Lars W; Uber, Amy; Montissol, Sophia; Patel, Parth; Donnino, Michael W

    2015-01-01

    Pyruvate dehydrogenase (PDH) activity is altered in many human disorders. Current methods require tissue samples and yield inconsistent results. We describe a modified method for measuring PDH activity from isolated human peripheral blood mononuclear cells (PBMCs). RESULTS/METHODOLOGY: We found that PDH activity and quantity can be successfully measured in human PBMCs. Freeze-thaw cycles cannot efficiently disrupt the mitochondrial membrane. Processing time of up to 20 h does not affect PDH activity with proteinase inhibitor addition and a detergent concentration of 3.3% showed maximum yield. Sample protein concentration is correlated to PDH activity and quantity in human PBMCs from healthy subjects. Measuring PDH activity from PBMCs is a novel, easy and less invasive way to further understand the role of PDH in human disease.

  5. [Intrapartum foetal monitoring: from stethoscope to ST analysis of the ECG].

    PubMed

    Westerhuis, Michelle E M H; Strasser, Sanne M; Moons, Karel G M; Mol, Ben Willem J; Visser, Gerard H A; Kwee, Anneke

    2009-01-01

    Since the 1970s, intrapartum monitoring of the distressed foetus has been managed by continuous registration of the foetal heart rate, together with uterine activity (cardiotocogram; CTG). Use of CTG without additional foetal information leads to unnecessary interventions because of the high number of false-positive signals. Foetal blood sampling (FBS) is a solution to this problem, but is not always consistently carried out. Automated ST analysis of the foetal electrocardiogram (STAN method), combined with the CTG, may lead to reduction of metabolic acidosis, fewer interventions and fewer foetal blood samples. A disadvantage of application of the STAN method is that it is based on visual interpretation of the CTG, with large inter- and intraobserver variability. In spite of this shortcoming the method may be promising.

  6. Parvovirus B19 infection transmitted by transfusion of red blood cells confirmed by molecular analysis of linked donor and recipient samples.

    PubMed

    Yu, Mei-Ying W; Alter, Harvey J; Virata-Theimer, Maria Luisa A; Geng, Yansheng; Ma, Li; Schechterly, Cathy A; Colvin, Camilla A; Luban, Naomi L C

    2010-08-01

    Extremely high viremic levels of parvovirus B19 (B19V) can be found in acutely infected, but asymptomatic donors. However, reports of transmission by single-donor blood components are rare. In this prospective study, paired donor-recipient samples were used to investigate the transfusion risk. Posttransfusion plasma or blood samples from recipients were tested for B19V DNA by polymerase chain reaction, generally at 4 and 8 weeks, and for anti-B19V immunoglobulin (Ig)G by enzyme immunoassay, at 12 and 24 weeks. To rule out infection unrelated to transfusion, pretransfusion samples and linked donor's samples for each B19V DNA-positive recipient were assayed for B19V DNA and anti-B19V IgG and IgM. To confirm transmission, sequencing and phylogenetic analysis were performed. A total of 14 of 869 (1.6%) recipients were B19V DNA positive, but only 1 of 869 (0.12%; 95% confidence interval, 0.0029%-0.6409%) was negative for B19V DNA and anti-B19V IgG before transfusion and seroconverted posttransfusion. This newly infected patient received 5 × 10(10) IU B19V DNA in one red blood cell (RBC) unit from an acutely infected anti-B19V-negative donor in addition to RBCs from three other donors that cumulatively contained 1320 IU of anti-B19V IgG. DNA sequencing and phylogenetic analysis showed that sequences from the linked donor and recipient were identical (Genotype 1), thus establishing transfusion transmission. The 0.12% transmission rate documented here, although low, could nonetheless result in hundreds or thousands of infections annually in the United States based on calculated confidence limits. Although most would be asymptomatic, some could have severe clinical outcomes, especially in neonates and those with immunocompromised or hemolytic states. © 2010 American Association of Blood Banks.

  7. A novel fast method for aqueous derivatization of THC, OH-THC and THC-COOH in human whole blood and urine samples for routine forensic analyses.

    PubMed

    Stefanelli, Fabio; Pesci, Federica Giorgia; Giusiani, Mario; Chericoni, Silvio

    2018-04-01

    A novel aqueous in situ derivatization procedure with propyl chloroformate (PCF) for the simultaneous, quantitative analysis of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxy-Δ 9 -tetrahydrocannabinol (OH-THC) and 11-nor-Δ 9 -tetrahydrocannabinol-carboxylic acid (THC-COOH) in human blood and urine is proposed. Unlike current methods based on the silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] added in an anhydrous environment, this new proposed method allows the addition of the derivatizing agent (propyl chloroformate, PCF) directly to the deproteinized blood and recovery of the derivatives by liquid-liquid extraction. This novel method can be also used for hydrolyzed urine samples. It is faster than the traditional method involving a derivatization with trimethyloxonium tetrafluoroborate. The analytes are separated, detected and quantified by gas chromatography-mass spectrometry in selected ion monitoring mode (SIM). The method was validated in terms of selectivity, capacity of identification, limits of detection (LOD) and quantification (LOQ), carryover, linearity, intra-assay precision, inter-assay precision and accuracy. The LOD and LOQ in hydrolyzed urine were 0.5 and 1.3 ng/mL for THC and 1.2 and 2.6 ng/mL for THC-COOH, respectively. In blood, the LOD and LOQ were 0.2 and 0.5 ng/mL for THC, 0.2 and 0.6 ng/mL for OH-THC, and 0.9 and 2.4 ng/mL for THC-COOH, respectively. This method was applied to 35 urine samples and 50 blood samples resulting to be equivalent to the previously used ones with the advantage of a simpler method and faster sample processing time. We believe that this method will be a more convenient option for the routine analysis of cannabinoids in toxicological and forensic laboratories. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Stability of Phosphatidylethanol in Dry Blood Spot Cards.

    PubMed

    Bakhireva, Ludmila N; Shrestha, Shikhar; Gutierrez, Hilda L; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee

    2016-05-01

    The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, -80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at -80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature-time interaction on PEth degradation over the first 9 months. The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  9. Stability of Phosphatidylethanol in Dry Blood Spot Cards

    PubMed Central

    Bakhireva, Ludmila N.; Shrestha, Shikhar; Gutierrez, Hilda L.; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee

    2016-01-01

    Background The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Methods Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, −80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at −80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature–time interaction on PEth degradation over the first 9 months. Results The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. Conclusions PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. PMID:26519350

  10. Whole Blood Cytokine Response to Local Traffic-Related Particulate Matter in Peruvian Children With and Without Asthma

    PubMed Central

    Negherbon, Jesse P.; Romero, Karina; Williams, D’Ann L.; Guerrero-Preston, Rafael E.; Hartung, Thomas; Scott, Alan L.; Breysse, Patrick N.; Checkley, William; Hansel, Nadia N.

    2017-01-01

    This study sought to investigate if acute phase immune responses of whole blood from Peruvian children with controlled and uncontrolled asthma differed from children without asthma, following exposure to traffic-related particulate matter (TRPM). TRPM, including particulate matter from diesel combustion, has been shown to stimulate acute airway inflammation in individuals with and without asthma. For this study, a whole blood assay (WBA) was used to test peripheral whole blood samples from 27 children with asthma, and 12 without asthma. Participant blood samples were stimulated, ex vivo, for 24-h with an aqueous extract of TRPM that was collected near study area highways in Lima, Peru. All participant blood samples were tested against the same TRPM extract, in addition to purified bacterial endotoxin and pyrogen-free water, which served as positive and negative WBA controls, respectively. The innate and adaptive cytokine responses were evaluated in cell-free supernatants of the whole blood incubations. Comparatively similar levels were recorded for nine out of the 10 cytokines measured [e.g., – Interleukin (IL)-1β, IL-6, IL-10], regardless of study participant asthma status. However, IL-8 levels in TRPM-stimulated blood from children with uncontrolled asthma were diminished, compared to subjects without asthma (633 pg/ml vs. 1,023 pg/ml, respectively; p < 0.01); IL-8 responses for subjects with controlled asthma were also reduced, but to a lesser degree (799 pg/ml vs. 1,023 pg/ml, respectively; p = 0.10). These relationships were present before, and after, adjusting for age, sex, obesity/overweight status, C-reactive protein levels, and residential proximity to the study area’s major roadway. For tests conducted with endotoxin, there were no discernible differences in cytokine response between groups, for all cytokines measured. The WBA testing conducted for this study highlighted the capacity of the TRPM extract to potently elicit the release of IL-8 from the human whole blood system. Although the small sample size of the study limits the capacity to draw definitive conclusions, the IL-8 responses suggest that that asthma control may be associated with the regulation of a key mediator in neutrophil chemotaxis, at a systemic level, following exposure to PM derived from traffic-related sources. PMID:28424616

  11. An experimental study of postmortem decomposition of methomyl in blood.

    PubMed

    Kawakami, Yuka; Fuke, Chiaki; Fukasawa, Maki; Ninomiya, Kenji; Ihama, Yoko; Miyazaki, Tetsuji

    2017-03-01

    Methomyl (S-methyl-1-N-[(methylcarbamoyl)oxy]thioacetimidate) is a carbamate pesticide. It has been noted that in some cases of methomyl poisoning, methomyl is either not detected or detected only in low concentrations in the blood of the victims. However, in such cases, methomyl is detected at higher concentrations in the vitreous humor than in the blood. This indicates that methomyl in the blood is possibly decomposed after death. However, the reasons for this phenomenon have been unclear. We have previously reported that methomyl is decomposed to dimethyl disulfide (DMDS) in the livers and kidneys of pigs but not in their blood. In addition, in the field of forensic toxicology, it is known that some compounds are decomposed or produced by internal bacteria in biological samples after death. This indicates that there is a possibility that methomyl in blood may be decomposed by bacteria after death. The aim of this study was therefore to investigate whether methomyl in blood is decomposed by bacteria isolated from human stool. Our findings demonstrated that methomyl was decomposed in human stool homogenates, resulting in the generation of DMDS. In addition, it was observed that three bacterial species isolated from the stool homogenates, Bacillus cereus, Pseudomonas aeruginosa, and Bacillus sp., showed methomyl-decomposing activity. The results therefore indicated that one reason for the difficulty in detecting methomyl in postmortem blood from methomyl-poisoning victims is the decomposition of methomyl by internal bacteria such as B. cereus, P. aeruginosa, and Bacillus sp. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Potential Use of Salivary Markers for Longitudinal Monitoring of Inflammatory Immune Responses to Vaccination

    PubMed Central

    Garssen, Johan; Sandalova, Elena

    2016-01-01

    Vaccination, designed to trigger a protective immune response against infection, is a trigger for mild inflammatory responses. Vaccination studies can address the question of inflammation initiation, levels, and resolution as well as its regulation for respective studied pathogens. Such studies largely based on analyzing the blood components including specific antibodies and cytokines were usually constrained by number of participants and volume of collected blood sample. Hence, blood-based studies may not be able to cover the full dynamic range of inflammation responses induced by vaccination. In this review, the potential of using saliva in addition to blood for studying the kinetics of inflammatory response studies was assessed. Saliva sampling is noninvasive and has a great potential to be used for studies aimed at analysing the magnitude, time course, and variance in immune responses, including inflammation after vaccination. Based on a literature survey of inflammatory biomarkers that can be determined in saliva and an analysis of how these biomarkers could help to understand the mechanisms and dynamics of immune reactivity and inflammation, we propose that the saliva-based approach might have potential to add substantial value to clinical studies, particularly in vulnerable populations such as infants, toddlers, and ill individuals. PMID:27022211

  13. Evaluation of two glucose meters and interference corrections for screening neonatal hypoglycemia.

    PubMed

    Wada, Yuka; Nakamura, Tomoo; Kaneshige, Masao; Takahashi, Shigehiro; Fujinaga, Hideshi; Tsukamoto, Keiko; Ito, Yushi; Sago, Haruhiko

    2015-08-01

    Many neonatal intensive care and maternal units still use self-monitoring of blood glucose (SMBG) devices as a tool to aid diagnosis despite the introduction of point-of-care testing (POCT) devices, which are known to have higher accuracy. We evaluated the performance of two glucose meters, the StatStrip (Nova Biomedical), a POCT device, and the Medisafe Mini (Terumo), an SMBG device, to detect hypoglycemia in neonates. In addition, we evaluated the interference of hematocrit, acetaminophen and ascorbic acid. Whole blood samples were drawn from neonates who were at risk of hypoglycemia and analyzed with the StatStrip and Medisafe Mini. The results were further confirmed with blood gas analyzers ABL825 and BM6050. To evaluate the interference of hematocrit, acetaminophen and ascorbic acid, concentrated solutions of glucose and interfering substances were gravimetrically prepared and analyzed. Among the 222 blood samples analyzed, results from the StatStrip were more closely aligned to those of the ABL825 at all levels of glucose than the Medisafe Mini. StatStrip appears to be unaffected by hematocrit, ascorbic acid or acetaminophen. We recommend its use in neonates in hospital. Further studies are required to identify other interference effects. © 2014 Japan Pediatric Society.

  14. Epstein-Barr virus DNA loads in adult human immunodeficiency virus type 1-infected patients receiving highly active antiretroviral therapy

    NASA Technical Reports Server (NTRS)

    Ling, Paul D.; Vilchez, Regis A.; Keitel, Wendy A.; Poston, David G.; Peng, Rong Sheng; White, Zoe S.; Visnegarwala, Fehmida; Lewis, Dorothy E.; Butel, Janet S.

    2003-01-01

    Patients with human immunodeficiency virus type 1 (HIV-1) infection are at high risk of developing Epstein-Barr virus (EBV)-associated lymphoma. However, little is known of the EBV DNA loads in patients receiving highly active antiretroviral therapy (HAART). Using a real-time quantitative polymerase chain reaction assay, we demonstrated that significantly more HIV-1-infected patients receiving HAART than HIV-1-uninfected volunteers had detectable EBV DNA in blood (57 [81%] of 70 vs. 11 [16%] of 68 patients; P=.001) and saliva (55 [79%] of 68 vs. 37 [54%] of 68 patients; P=.002). The mean EBV loads in blood and saliva samples were also higher in HIV-1-infected patients than in HIV-1-uninfected volunteers (P=.001). The frequency of EBV detection in blood was associated with lower CD4+ cell counts (P=.03) among HIV-1-infected individuals, although no differences were observed in the EBV DNA loads in blood or saliva samples in the HIV-1-infected group. Additional studies are needed to determine whether EBV-specific CD4+ and CD8+ cells play a role in the pathogenesis of EBV in HIV-1-infected patients receiving HAART.

  15. Quantification of all 209 PCB congeners in blood-Can indicators be used to calculate the total PCB blood load?

    PubMed

    Kraft, M; Rauchfuss, K; Sievering, S; Wöckner, M; Neugebauer, F; Fromme, H

    2017-03-01

    Polychlorinated biphenyls (PCBs) are a substance group of 209 theoretically possible compounds. The human body burden of PCBs is commonly calculated based on so-called indicator congeners such as PCB 138, PCB 153 and PCB 180, which are analyzed in human blood. The German "Human Biomonitoring (HBM) Commission" assumes that the sum of these indicator congeners multiplied by a factor of 2 represents the total PCB burden. This norm is based on data obtained from exposure studies after dietary intake. Data from indoor air shows a different congener pattern, which might lead to a relatively higher intake of lower chlorinated PCBs by inhalation. In two independent studies with adult participants from two regions in Germany, we measured all 209 PCB congeners in 44 whole blood and 42 plasma samples. Participants from the whole blood study group had additional exposure to PCBs via indoor air. With our analytical method, 141 individual PCB congeners, 27 coeluted pairs of PCB congeners and 2 records of 3 and 4 coeluted PCBs could be determined. Thus, 172 analysis results were reported per sample. In the whole blood samples, 50 congeners showed values below the limit of quantification (LOQ), whereas 94 congeners could not be detected in any of plasma samples. Total PCB concentrations (Σ 209 PCB congeners, incl. ½ LOQ) in the whole blood samples ranged from 99 to 2152ng PCB/g lipid (Median: 454ng/g lipid; 95th Percentile: 1404ng/g lipid). The sum of all 209 measured PCB (incl. ½ LOQ) in plasma samples showed levels between 52 and 933ng PCB/g lipid (Median: 226ng/g lipid; 95th Percentile: 642ng/g lipid). Our results show that the burden of PCBs on the human body is caused mainly by the three highly chlorinated indicator congeners PCB 138, PCB 153 and PCB 180. In median approximately 50% of the total PCB content in human whole blood or plasma samples can be attributed to these congeners. Total PCB, calculated by multiplying the sum of the three indicator congeners by 2, showed a strong and highly significant correlation to the sum of all 209 measured congeners for each sample. A slightly stronger correlation in the whole blood samples could be achieved by choosing six indicator congeners, including the lower chlorinated congeners (PCB 28, 52 and 101) into the calculation. Although this difference is very small, it must be considered that higher PCB levels in indoor air than those measured in the present study might be associated with a higher burden of indoor-air-related congeners in exposed individuals. For precautionary reasons, it could therefore be recommended that the assessment of individuals exposed to PCB via indoor air should be carried out based on the sum of the 6 indicator congeners PCB 28, PCB 52, PCB 101, PCB 138, PCB 153 and PCB 180 multiplied by a factor of 2. Copyright © 2016 Elsevier GmbH. All rights reserved.

  16. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  17. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    PubMed

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood from an ear vein and the v. jug. Cutoffs of 1.0 mmol/L (ear vein) and 1.1 mmol/L (v. jug.) BHBA were determined to detect animals at greater risk to develop severe hyperketonemia. Applying these thresholds, excellent test characteristics, with sensitivities of 1.00 for both samples and specificities of 0.98 for the ear vein and 0.97 for the v. jug. were determined. These results demonstrate that the PX is a useful tool for detection of hyperketonemia in ewes. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Biological Profiles of Korean Atomic Bomb Survivors in Residence at Daegu and Kyungbuk, Republic of Korea

    PubMed Central

    Jhun, Hyung-Joon; Kim, Byoung-Gwon; Kim, Su-Young; Koo, Bon-Min; Kim, Jin-Kook

    2008-01-01

    In 1945, many Koreans, in addition to Japanese, were killed or injured by the atomic bombs dropped on Hiroshima and Nagasaki, Japan. This study compared the biological profiles of Korean atomic bomb survivors in residence at Daegu and Kyungbuk, Republic of Korea with those of a representative sample of Koreans obtained during a similar period. We evaluated anthropometric measurements, blood pressure, blood cell counts, blood chemistry, and urinalysis of survivors (n=414) and age- and sex-matched controls (n=414) recruited from the third Korea National Health and Nutrition Examination Survey conducted in 2005. Univariate analyses revealed significantly higher systolic blood pressure, white blood cell count, and serum total cholesterol, triglycerides, high-density lipoprotein-cholesterol, and aspartate aminotransferase levels (p<0.01) in the survivors. Conversely, hemoglobin concentration, hematocrit, red blood cell count, and the proportion of positive urine occult blood (p<0.01) were lower in the survivors. Our findings suggest that biological profiles of Korean atomic bomb survivors were adversely affected by radiation exposure. PMID:19119455

  19. A refractometry-based glucose analysis of body fluids.

    PubMed

    Zirk, Kai; Poetzschke, Harald

    2007-05-01

    In principle, refractometry appears to be a suitable method for the measurement of glucose concentrations in body fluids (such as blood and the intercellular fluid), even though the refractive index of the measured samples, as an additive property, is not specific. But, if certain conditions are fulfilled, the glucose content can be calculated using the refractive index in combination with values from a further measurement. This study describes the determination of the glucose content using refractometry in human blood serum derivates, which were selected - due to their ready availability - to be used as a model for interstitial fluid. Refractometry of body fluids requires the elimination of disturbing components from the measurement sample. First of all, a homogenous fluid (i.e. consisting of one phase) is required, so that all cells and components in suspension need to be separated out. Furthermore, certain dissolved macromolecular components which are known to disturb the measurement process must also be removed. In human serum samples which had been ultrafiltrated with a range of ultrafilters of different pore sizes, a comparative evaluation showed that only ultrafiltration through a filter with a separation limit of between 3 and 30kDa resulted in maximal reduction of the refractive index (compared to native serum), whereas ultrafilters with greater separation limits did not. The total content of osmotically active solutes (the tonicity) also exerts a clear influence. However, exemplary measurements in blood plasma fluid from one volunteer showed that the electrical conductivity is (without an additive component) directly proportional to the osmolality: physiological changes in the state of body hydration (hyperhydration and dehydration) do not lead to any considerable changes in the relation between ionised and uncharged solute particles, but instead result in a sufficiently clear dilution or concentration of the blood fluid's low molecular components. This finding allows the use of the--technically easy to measure--electrical conductivity as a measure for the tonicity of the measurement samples. Using measurements of these two parameters--refractive index and electrical conductivity--in blood serum obtained from a healthy volunteer, a two-dimensional calibration function (calibration matrix) for the assessment of the glucose content of ultrafiltrated human blood serum was constructed, and the measurement of blood glucose levels in non-diabetic (four females and four males) volunteers in comparison to a reference method was evaluated showing (as a proof of concept) a linear association. Assessment of the inaccuracy of these measurements made with the described measuring devices and methods showed a deviation from the reference values of less than 10%. An estimation of the maximum possible error showed relative deviations (maximum measurement uncertainties) of up to 20%.

  20. Hemolysis area: A new parameter of erythrocyte osmotic fragility for screening of thalassemia trait

    PubMed Central

    Tatu, Thanusak; Sweatman, Denis

    2018-01-01

    BACKGROUND: One-tube osmotic fragility test (OFT) is widely used for screening thalassemia traits. Interobserver variation may occur with 0.36% NaCl-based OFT due to the naked eye result reading style. PURPOSE: The purpose of this study was to establish and evaluate the novel numerical OFT-based parameter, so-called hemolysis area (HA), in screening thalassemia traits. MATERIALS AND METHODS: The portable spectrophotometer was invented capable of calculating the HA values. The HA values were then compared among 69, 156, and 19 blood samples having positive, negative, and suspicious 0.36% NaCl-based OFT results, respectively; 109 and 135 blood samples having mean corpuscular volume (MCV) ≤80 fL and >80 fL, respectively; and 138 and 106 blood samples having mean corpuscular hemoglobin (MCH) ≤27 pg and >27 pg, respectively. In addition, the HA values were compared in 166 blood samples having different globin gene genotypes. Finally, the HA cutoff value was determined by receiver operation curve (ROC) analysis. RESULTS: The HA values in samples having positive, suspicious, and negative 0.36% NaCl-based OFT were 33.3 ± 14.4, 42.9 ± 10.5, and 65.3 ± 13.4, respectively; in sample having MCV ≤80 fL and >80 fL were 43.1 ± 19.6 and 63.8 ± 14.5, respectively; and in samples having MCH ≤27 pg and >27 pg were 46.7 ± 20.1 and 64.8 ± 14.2, respectively. The HA values in normal, hemoglobin E, SEA-α thalassemia 1, and β-thalassemia traits were 67.1 ± 12.6, 36.4 ± 13.9, 20.2 ± 4.8, and 18.6 ± 1.1, respectively. All were significantly different. ROC analysis established 52.4 as the HA cutoff that had comparable effectiveness to the conventional screening tests. CONCLUSION: The new HA value was effective and could be an alternative choice for screening thalassemia traits. PMID:29692590

  1. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  2. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    DOEpatents

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  3. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    PubMed

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  4. Glycaemic index and glycaemic load values of commonly consumed foods in the United Arab Emirates.

    PubMed

    Al Dhaheri, Ayesha S; Henry, C Jeyakumar K; Mohamad, Maysm N; Ohuma, Eric O; Ismail, Leila Cheikh; Al Meqbaali, Fatima T; Jarrar, Amjad H

    2017-04-01

    Glycaemic index (GI) and glycaemic load (GL) values of some commonly consumed foods in the United Arab Emirates were determined with an aim of adding these values to the existing international table of GI and GL values. In all, eighteen test foods categorised into breads (n 5), entrée dishes (n 3), main dishes (n 5) and sweet dishes (n 5) were tested. For each test food, at least fifteen healthy participants consumed 25 or 50 g available carbohydrate portions of a reference food (glucose), which was tested three times, and a test food after an overnight fast, was tested once, on separate occasions. Capillary blood samples were obtained by finger-prick and blood glucose was measured using clinical chemistry analyser. A fasting blood sample was obtained at baseline and before consumption of test foods. Additional blood samples were obtained at 15, 30, 45, 60, 90 and 120 min after the consumption of each test food. The GI value of each test food was calculated as the percentage of the incremental area under the blood glucose curve (IAUC) for the test food of each participant divided by the average IAUC for the reference food of the same participant. The GI values of tested foods ranged from low (55 or less) to high (70 or more). The GI values of various breads and rice-containing dishes were comparable with previously published values. This study provides GI and GL values of previously untested traditional Emirati foods which could provide a useful guide on dietary recommendations for the Emirati population.

  5. RNA-Stabilized Whole Blood Samples but Not Peripheral Blood Mononuclear Cells Can Be Stored for Prolonged Time Periods Prior to Transcriptome Analysis

    PubMed Central

    Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea

    2011-01-01

    Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280

  6. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe

    2013-01-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126

  7. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  8. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    PubMed

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  9. Characterization of the surface physico-chemistry of plasticized PVC used in blood bag and infusion tubing.

    PubMed

    Al Salloum, H; Saunier, J; Dazzi, A; Vigneron, J; Etcheberry, A; Marlière, C; Aymes-Chodur, C; Herry, J M; Bernard, M; Jubeli, E; Yagoubi, N

    2017-06-01

    Commercial infusion tubing and blood storage devices (tubing, blood and platelets bags) made of plasticized PVC were analyzed by spectroscopic, chromatographic and microscopic techniques in order to identify and quantify the additives added to the polymer (lubricants, thermal stabilizers, plasticizers) and to put into evidence their blooming onto the surface of the devices. For all the samples, deposits were observed on the surface but with different kinds of morphologies. Ethylene bis amide lubricant and metallic stearate stabilizers were implicated in the formation of these layers. In contact with aqueous media, these insoluble deposits were damaged, suggesting a possible particulate contamination of the infused solutions. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Validation of Marek's disease diagnosis and monitoring of Marek's disease vaccines from samples collected in FTA cards.

    PubMed

    Cortes, Aneg L; Montiel, Enrique R; Gimeno, Isabel M

    2009-12-01

    The use of Flinders Technology Associates (FTA) filter cards to quantify Marek's disease virus (MDV) DNA for the diagnosis of Marek's disease (MD) and to monitor MD vaccines was evaluated. Samples of blood (43), solid tumors (14), and feather pulp (FP; 36) collected fresh and in FTA cards were analyzed. MDV DNA load was quantified by real-time PCR. Threshold cycle (Ct) ratios were calculated for each sample by dividing the Ct value of the internal control gene (glyceraldehyde-3-phosphate dehydrogenase) by the Ct value of the MDV gene. Statistically significant correlation (P < 0.05) within Ct ratios was detected between samples collected fresh and in FTA cards by using Pearson's correlation test. Load of serotype 1 MDV DNA was quantified in 24 FP, 14 solid tumor, and 43 blood samples. There was a statistically significant correlation between FP (r = 0.95), solid tumor (r = 0.94), and blood (r = 0.9) samples collected fresh and in FTA cards. Load of serotype 2 MDV DNA was quantified in 17 FP samples, and the correlation between samples collected fresh and in FTA cards was also statistically significant (Pearson's coefficient, r = 0.96); load of serotype 3 MDV DNA was quantified in 36 FP samples, and correlation between samples taken fresh and in FTA cards was also statistically significant (r = 0.84). MDV DNA samples extracted 3 days (t0) and 8 months after collection (t1) were used to evaluate the stability of MDV DNA in archived samples collected in FTA cards. A statistically significant correlation was found for serotype 1 (r = 0.96), serotype 2 (r = 1), and serotype 3 (r = 0.9). The results show that FTA cards are an excellent media to collect, transport, and archive samples for MD diagnosis and to monitor MD vaccines. In addition, FTA cards are widely available, inexpensive, and adequate for the shipment of samples nationally and internationally.

  11. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    PubMed

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  12. Blood harmane, blood lead, and severity of hand tremor: evidence of additive effects.

    PubMed

    Louis, Elan D; Factor-Litvak, Pam; Gerbin, Marina; Slavkovich, Vesna; Graziano, Joseph H; Jiang, Wendy; Zheng, Wei

    2011-03-01

    Tremor is a widespread phenomenon in human populations. Environmental factors are likely to play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-β]indole) is a potent tremor-producing β-carboline alkaloid. Lead is another tremor-producing neurotoxicant. The effects of harmane and lead with respect to tremor have been studied in isolation. We tested the hypothesis that tremor would be particularly severe among individuals who had high blood concentrations of both of these toxicants. Blood concentrations of harmane and lead were each quantified in 257 individuals (106 essential tremor cases and 151 controls) enrolled in an environmental epidemiological study. Total tremor score (range = 0-36) was a clinical measure of tremor severity. The total tremor score ranged from 0 to 36, indicating that a full spectrum of tremor severities was captured in our sample. Blood harmane concentration correlated with total tremor score (p = 0.007), as did blood lead concentration (p = 0.045). The total tremor score was lowest in participants with both low blood harmane and lead concentrations (8.4 ± 8.2), intermediate in participants with high concentrations of either toxicant (10.5 ± 9.8), and highest in participants with high concentrations of both toxicants (13.7 ± 10.4) (p=0.01). Blood harmane and lead concentrations separately correlated with total tremor scores. Participants with high blood concentrations of both toxicants had the highest tremor scores, suggesting an additive effect of these toxicants on tremor severity. Given the very high population prevalence of tremor disorders, identifying environmental determinants is important for primary disease prevention. Copyright © 2010 Elsevier Inc. All rights reserved.

  13. Blood Harmane, Blood Lead, and Severity of Hand Tremor: Evidence of Additive Effects

    PubMed Central

    Louis, Elan D.; Factor-Litvak, Pam; Gerbin, Marina; Slavkovich, Vesna; Graziano, Joseph H; Jiang, Wendy; Zheng, Wei

    2010-01-01

    Background Tremor is a widespread phenomenon in human populations. Environmental factors are likely to play an etiological role. Harmane (1-methyl-9H-pyrido[3,4-β]indole) is a potent tremor-producing β-carboline alkaloid. Lead is another tremor-producing neurotoxicant. The effects of harmane and lead with respect to tremor have been studied in isolation. Objectives We tested the hypothesis that tremor would be particularly severe among individuals who had high blood concentrations of both of these toxicants. Methods Blood concentrations of harmane and lead were each quantified in 257 individuals (106 essential tremor cases and 151 controls) enrolled in an environmental epidemiological study. Total tremor score (range = 0 – 36) was a clinical measure of tremor severity. Results The total tremor score ranged from 0 – 36, indicating that a full spectrum of tremor severities was captured in our sample. Blood harmane concentration correlated with total tremor score (p = 0.007), as did blood lead concentration (p = 0.045). The total tremor score was lowest in participants with both low blood harmane and lead concentrations (8.4 ± 8.2), intermediate in participants with high concentrations of either toxicant (10.5 ± 9.8), and highest in participants with high concentrations of both toxicants (13.7 ± 10.4)(p = 0.01). Conclusions Blood harmane and lead concentrations separately correlated with total tremor scores. Participants with high blood concentrations of both toxicants had the highest tremor scores, suggesting an additive effect of these toxicants on tremor severity. Given the very high population prevalence of tremor disorders, identifying environmental determinants is important for primary disease prevention. PMID:21145352

  14. Miltenberger blood group typing by real-time polymerase chain reaction (qPCR) melting curve analysis in Thai population.

    PubMed

    Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T

    2015-12-01

    To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.

  15. A pilot study evaluating changes to haematological and biochemical tests after Flexible Ureterorenoscopy for the treatment of kidney stones.

    PubMed

    Moyes, Alyson Jayne; Lamb, Rebecca May; Ella-Tongwiis, Peter; Pushkaran, Anish; Ahmed, Issam; Shergill, Iqbal; Hughes, Stephen Fôn

    2017-01-01

    Currently there is limited research documenting the changes in blood parameters, following Flexible Ureterorenoscopy. This study aims to determine whether there are any changes in haematology and biochemistry parameters, following Flexible Ureterorenoscopy for the treatment of kidney stones. 40 consecutive patients aged between 27-87 years (median 49 years) undergoing Flexible Ureterorenoscopy for the treatment of kidney stones were recruited (26 male, 14 female). Blood samples were collected from each patient at four time points: baseline (pre-operatively) followed by 30 minutes, 120 minutes and 240 minutes post-operatively. On these samples, routine haematological and biochemistry tests were carried out. In addition to the assessment of clinical parameters prospectively from the medical notes. There was a significant decrease observed following Flexible Ureterorenoscopy in the following parameters: lymphocytes (p = 0.007), eosinophils (p = 0.001), basophils (p = 0.001), haemoglobin (p = 0.002), red blood cells (p = 0.001), platelet count (p = 0.001), fibrinogen concentration (p = 0.001), von Willebrand factor (p = 0.046), C reactive protein (p = 0.01), total protein (p = 0.001), albumin (p = 0.001), globulin (p = 0.001) and alkaline phosphatase (p = 0.001). In addition, there was a significant increase observed in the following parameters: white blood cells (p = 0.001), neutrophils (p = 0.001), activated partial thromboplastin time (p = 0.001), total bilirubin (p = 0.012), creatinine (p = 0.008), sodium (p = 0.002) and potassium (p = 0.001). Limiting factors for this study were the sample size, and restriction on the recruitment time points. Significant changes were noted to occur in haematology and biochemistry parameters following Flexible Ureterorenoscopy. Some of the data presented in this study may represent the 'normal' post-operative response following FURS, as no major complications occurred, in the majority of our patients. This data on the 'normal response' will need to be validated but may ultimately aid clinicians in distinguishing patients at risk of complications, if reproduced in larger multi-centre studies.

  16. Simian immunodeficiency virus (SIV)/immunoglobulin G immune complexes in SIV-infected macaques block detection of CD16 but not cytolytic activity of natural killer cells.

    PubMed

    Wei, Qing; Stallworth, Jackie W; Vance, Patricia J; Hoxie, James A; Fultz, Patricia N

    2006-07-01

    Natural killer cells are components of the innate immune system that play an important role in eliminating viruses and malignant cells. Using simian immunodeficiency virus (SIV) infection of macaques as a model, flow cytometry revealed a gradual loss of CD16+ NK cell numbers that was associated with disease progression. Of note, the apparent loss of NK cells was detected in whole-blood samples but not in isolated peripheral blood mononuclear cells (PBMC), suggesting that an inhibitor(s) of the antibody used to detect CD16, the low-affinity immunoglobulin G (IgG) receptor, was present in blood but was removed during PBMC isolation. (Actual decreases in CD16+ cell numbers in PBMC generally were not detected until animals became lymphopenic.) The putative decrease in CD16+ cell numbers in whole blood correlated with increasing SIV-specific antibody titers and levels of plasma virion RNA. With the addition of increasing amounts of plasma from progressor, but not nonprogressor, macaques to PBMC from an uninfected animal, the apparent percentage of CD16+ cells and the mean fluorescence intensity of antibodies binding to CD16 declined proportionately. A similar decrease was observed with the addition of monomeric IgG (mIgG) and IgG immune complexes (IgG-ICs) purified from the inhibitory plasma samples; some of the ICs contained SIV p27(gag) antigen and/or virions. Of interest, addition of purified IgG/IgG-ICs to NK cell lytic assays did not inhibit killing of K562 cells. These results indicate that during progressive SIV and, by inference, human immunodeficiency virus disease, CD16+ NK cell numbers can be underestimated, or the cells not detected at all, when one is using a whole-blood fluorescence-activated cell sorter assay and a fluorochrome-labeled antibody that can be blocked by mIgG or IgG-ICs. Although this blocking had no apparent effect on NK cell activity in vitro, the in vivo effects are unknown.

  17. Effect of amlodipine, efonidipine, and trichlormethiazide on home blood pressure and upper-normal microalbuminuria assessed by casual spot urine test in essential hypertensive patients.

    PubMed

    Hosaka, Miki; Inoue, Ryusuke; Satoh, Michihiro; Watabe, Daisuke; Hanazawa, Tomohiro; Ohkubo, Takayoshi; Asayama, Kei; Obara, Taku; Imai, Yutaka

    2018-01-01

    The aim of this study was to assess the effects of irbesartan alone and combined with amlodipine, efonidipine, or trichlormethiazide on blood pressure (BP) and urinary albumin (UA) excretion in hypertensive patients with microalbuminuria (30≤UA/creatinine (Cr) ratio [UACR] <300 mg/g Cr) and upper-normal microalbuminuria (10≤UACR<30 mg/g Cr). This randomized controlled trial enrolled 175 newly diagnosed and untreated hypertensive patients (home systolic blood pressure [SBP]≥135 mmHg; 10≤UACR<300 mg/g Cr of casual spot urine at the first visit to clinic). All patients were treated with irbesartan (week 0). Patients who failed to achieve home SBP ≤125 mmHg on 8-week irbesartan monotherapy (nonresponders, n = 115) were randomized into three additional drug treatment groups: trichlormethiazide (n = 42), efonidipine (n = 39), or amlodipine (n = 34). Irbesartan monotherapy decreased home SBP and first morning urine samples (morning UACR) for 8 weeks (p < 0.0001). At 8 weeks after randomization, all three additional drugs decreased home SBP (p < 0.0002) and trichlormethiazide significantly decreased morning UACR (p = 0.03). Amlodipine decreased morning UACR in patients with microalbuminuria based on casual spot urine samples (p = 0.048). However, multivariate analysis showed that only higher home SBP and UACR at week 8, but not any additional treatments, were significantly associated with UACR reduction between week 8 and week 16. In conclusion, crucial points of the effects of combination therapy on UACR were basal UACR and SBP levels. The effect of trichlormethiazide or amlodipine treatment in combination with irbesartan treatment on microalbuminuria needs to be reexamined based on a larger sample size after considering basal UACR and SBP levels.

  18. Concentrations of cadmium, lead, and zinc in fish from mining-influenced waters of northeastern Oklahoma: Sampling of blood, carcass, and liver for aquatic biomonitoring

    USGS Publications Warehouse

    Brumbaugh, W.G.; Schmitt, C.J.; May, T.W.

    2005-01-01

    The Tri-States Mining District (TSMD) of Missouri (MO), Kansas (KS), and Oklahoma (OK), USA, was mined for lead (Pb) and zinc (Zn) for more than a century. Mining ceased more than 30 years ago, but wastes remain widely distributed in the region, and there is evidence of surface- and groundwater contamination in the Spring River-Neosho River (SR-NR) system of northeastern OK. In October 2001, we collected a total of 74 fish from six locations in the SR-NR system that included common carp (Cyprinus carpio), channel- and flathead catfish (Ictalurus punctatus and Pylodictis olivaris), largemouth- and spotted bass (Micropterus salmoides and Micropterus punctulatus), and white crappie (Pomoxis annularis). We obtained additional fish from locations in MO that included three reference sites and one site that served as a "positive control" (heavily contaminated by Pb). Blood, carcass (headed, eviscerated, and scaled) and liver (carp only) samples were analyzed for cadmium (Cd), Pb, and Zn. Our objectives were to assess the degree to which fish from the OK portion of the SR-NR system are contaminated by these elements and to evaluate fish blood sampling for biomonitoring. Concentrations of Cd and Pb in carp and catfish from OK sites were elevated and Pb concentrations of some approached those of the highly contaminated site in MO, but concentrations in bass and crappie were relatively low. For Zn, correlations were weak among concentrations in the three tissues and none of the samples appeared to reflect site contamination. Variability was high for Cd in all three tissues of carp; differences between sites were statistically significant (p < 0.05) only for blood even though mean liver concentrations were at least 100-fold greater than those in blood. Blood concentrations of Cd and Pb were positively correlated (r 2 = 0.49 to 0.84) with the concentration of the same element in carp and catfish carcasses or in carp livers, and the corresponding multiple regression models were highly significant (p < 0.001). Our data indicate that potentially nonlethal blood sampling can be useful for monitoring of selected metals in carp, catfish, and perhaps other fishes. ?? 2005 Springer Science+Business Media, Inc.

  19. Value of molecular monitoring during the treatment of chronic myeloid leukemia: a Cancer and Leukemia Group B study.

    PubMed

    Stock, W; Westbrook, C A; Peterson, B; Arthur, D C; Szatrowski, T P; Silver, R T; Sher, D A; Wu, D; Le Beau, M M; Schiffer, C A; Bloomfield, C D

    1997-01-01

    Disappearance of the Philadelphia chromosome during treatment for chronic myeloid leukemia (CML) has become an important therapeutic end point. To determine the additional value of molecular monitoring during treatment for CML, we performed a prospective, sequential analysis using quantitative Southern blot monitoring of BCR gene rearrangements of blood and marrow samples from Cancer and Leukemia Group B (CALGB) study 8761. Sixty-four previously untreated adults with chronic-phase CML who were enrolled onto CALGB 8761, a molecular-monitoring companion study to a treatment study for adults with chronic-phase CML (CALGB 9013). Treatment consisted of repetitive cycles of interferon alfa and low-dose subcutaneous cytarabine. Blood and marrow Southern blot quantitation of BCR gene rearrangements was compared with marrow cytogenetic analysis before the initiation of treatment and of specified points during therapy. Reverse-transcriptase polymerase chain reaction (RT-PCR) analysis was performed to detect residual disease in patients who achieved a complete response by Southern blot or cytogenetic analysis. Quantitative molecular monitoring by Southern blot analysis of blood samples was found to be equivalent to marrow monitoring at all time points. Twelve of 62 (19%) follow-up samples studied by Southern blot analysis had a complete loss of BCR gene rearrangement in matched marrow and blood specimens. Southern blot monitoring of blood samples was also found to be highly correlated to marrow cytogenetic evaluation at all points, although there were four discordant cases in which Southern blot analysis of blood showed no BCR gene rearrangement, yet demonstrated from 12% to 20% Philadelphia chromosome-positive metaphase cells in the marrow. RT-PCR analysis detected residual disease in five of six patients in whom no malignant cells were detected using Southern blot or cytogenetic analyses. Quantitative Southern blot analysis of blood samples may be substituted for bone marrow to monitor the response to therapy in CML and results in the need for fewer bone marrow examinations. To avoid overestimating the degree of response, marrow cytogenetic analysis should be performed when patients achieve a complete response by Southern blot monitoring. This approach provides a rational, cost-effective strategy to monitor the effect of treatment of individual patients, as well as to analyze large clinical trials in CML.

  20. Comparison of the image-derived radioactivity and blood-sample radioactivity for estimating the clinical indicators of the efficacy of boron neutron capture therapy (BNCT): 4-borono-2-18F-fluoro-phenylalanine (FBPA) PET study.

    PubMed

    Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p < 0.001). Image-derived radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA injection was minimal. We conclude that the image-derived T/B ratio can be reliably used by setting the VOI on the left ventricle at 30 min after FBPA administration and correcting for underestimation due to partial volume effect and reduction of FBPA blood radioactivity.

  1. Effect of delayed serum separation and storage temperature on serum glucose concentration in horse, dog, alpaca, and sturgeon.

    PubMed

    Collicutt, Nancy B; Garner, Bridget; Berghaus, Roy D; Camus, Melinda S; Hart, Kelsey

    2015-03-01

    Although delays between blood sample collection and analysis are common in veterinary medicine, the effect of prolonged serum-clot contact time on serum glucose concentration is not well established and species differences have not been elucidated. The objective was to investigate the effect of storage time and temperature on serum glucose concentration in stored whole blood samples from horse, dog, alpaca, and sturgeon. Whole blood specimens were divided into 7 no-additive tubes and serum was separated from one sample within one hour, serving as the reference sample. The remaining samples were stored at 4°C and 25°C, then centrifuged and serum glucose measured by automated analysis at 2, 4, and 8 hours postcollection. Glucose concentrations were compared using linear mixed models. The decline in serum glucose concentration for all samples stored at 4°C was not statistically significant, except for the 8-hour samples from sturgeon and dog. At 25°C, serum glucose concentration was comparable to reference values at 2 hours in sturgeon and alpaca, but significantly lower at 4 and 8 hours in those species, and at all time points in equine and canine specimens, being most prominent after 8 hours of storage in canine specimens. Storage at 4°C limits serum glucose decline for at least 4 hours in all species tested and up to 8 hours in specimens of horse and alpaca. At 25°C, serum-clot contact time should not exceed 1 hour in equine and canine samples, and 2 hours in specimens from alpaca and sturgeon. © 2014 American Society for Veterinary Clinical Pathology.

  2. Survey of Slaughtered Pigs for Occurrence of Ochratoxin A and Porcine Nephropathy in Serbia

    PubMed Central

    Milićević, Dragan; Jurić, Verica; Stefanović, Srđan; Jovanović, Milijan; Janković, Saša

    2008-01-01

    Samples of blood, kidney and liver were randomly selected from slaughtered pigs (n=90) and analyzed for ochratoxin A by HPLC. In addition, in order to obtain information on the occurrence of nephropathy, histological examinations were carried out. Of the 90 liver samples, 26.6% contained OTA in the range of 0.22–14.5 ng/g. The incidence of OTA in serum and kidney were very similar (31%, 33.3%), with a maximum concentration of 220.8 ng/mL, and 52.5 ng/g, respectively. Histopathological examination of kidneys confirmed tubulopathies with edema and cell vacuolization. In addition, hemorrhages and necrosis of proximal kidney tubules’ cells were found. PMID:19330066

  3. Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review

    PubMed Central

    Stoot, Lauren J.; Cairns, Nicholas A.; Cull, Felicia; Taylor, Jessica J.; Jeffrey, Jennifer D.; Morin, Félix; Mandelman, John W.; Clark, Timothy D.; Cooke, Steven J.

    2014-01-01

    Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous calibration and validation of these units and appreciation of their limitations. PMID:27293632

  4. Strategies to assess systemic exposure of chemicals in subchronic/chronic diet and drinking water studies.

    PubMed

    Saghir, Shakil A; Mendrala, Alan L; Bartels, Michael J; Day, Sue J; Hansen, Steve C; Sushynski, Jacob M; Bus, James S

    2006-03-15

    Strategies were developed for the estimation of systemically available daily doses of chemicals, diurnal variations in blood levels, and rough elimination rates in subchronic feeding/drinking water studies, utilizing a minimal number of blood samples. Systemic bioavailability of chemicals was determined by calculating area under the plasma concentration curve over 24 h (AUC-24 h) using complete sets of data (> or =5 data points) and also three, two, and one selected time points. The best predictions of AUC-24 h were made when three time points were used, corresponding to Cmax, a mid-morning sample, and C(min). These values were found to be 103 +/- 10% of the original AUC-24 h, with 13 out of 17 values ranging between 96 and 105% of the original. Calculation of AUC-24 h from two samples (Cmax and Cmin) or one mid-morning sample afforded slightly larger variations in the calculated AUC-24 h (69-136% of the actual). Following drinking water exposure, prediction of AUC-24 h using 3 time points (Cmax, mid-morning, and Cmin) was very close to actual values (80-100%) among mice, while values for rats were only 63% of the original due to less frequent drinking behavior of rats during the light cycle. Collection and analysis of 1-3 blood samples per dose may provide insight into dose-proportional or non-dose-proportional differences in systemic bioavailability, pointing towards saturation of absorption or elimination or some other phenomenon warranting further investigation. In addition, collection of the terminal blood samples from rats, which is usually conducted after 18 h of fasting, will be helpful in rough estimation of blood/plasma half-life of the compound. The amount of chemical(s) and/or metabolite(s) in excreta and their possible use as biomarkers in predicting the daily systemic exposure levels are also discussed. Determining these parameters in the early stages of testing will provide critical information to improve the appropriate design of other longer-term toxicity studies.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saghir, Shakil A.; Mendrala, Alan L.; Bartels, Michael J.

    Strategies were developed for the estimation of systemically available daily doses of chemicals, diurnal variations in blood levels, and rough elimination rates in subchronic feeding/drinking water studies, utilizing a minimal number of blood samples. Systemic bioavailability of chemicals was determined by calculating area under the plasma concentration curve over 24 h (AUC-24 h) using complete sets of data ({>=}5 data points) and also three, two, and one selected time points. The best predictions of AUC-24 h were made when three time points were used, corresponding to C {sub max}, a mid-morning sample, and C {sub min}. These values were foundmore » to be 103 {+-} 10% of the original AUC-24 h, with 13 out of 17 values ranging between 96 and 105% of the original. Calculation of AUC-24 h from two samples (C {sub max} and C {sub min}) or one mid-morning sample afforded slightly larger variations in the calculated AUC-24 h (69-136% of the actual). Following drinking water exposure, prediction of AUC-24 h using 3 time points (C {sub max}, mid-morning, and C {sub min}) was very close to actual values (80-100%) among mice, while values for rats were only 63% of the original due to less frequent drinking behavior of rats during the light cycle. Collection and analysis of 1-3 blood samples per dose may provide insight into dose-proportional or non-dose-proportional differences in systemic bioavailability, pointing towards saturation of absorption or elimination or some other phenomenon warranting further investigation. In addition, collection of the terminal blood samples from rats, which is usually conducted after 18 h of fasting, will be helpful in rough estimation of blood/plasma half-life of the compound. The amount of chemical(s) and/or metabolite(s) in excreta and their possible use as biomarkers in predicting the daily systemic exposure levels are also discussed. Determining these parameters in the early stages of testing will provide critical information to improve the appropriate design of other longer-term toxicity studies.« less

  6. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) Study: Methodological Details

    PubMed Central

    Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Datta, Manjula; Sudha, Vasudevan; Unnikrishnan, Ranjit; Nath, Lalith M; Das, Ashok Kumar; Madhu, Sri Venkata; Rao, Paturi Vishnupriya; Shukla, Deepak Kumar; Kaur, Tanvir; Ali, Mohammed K; Mohan, Viswanathan

    2011-01-01

    Background Currently available estimates of diabetes prevalence in India are based on published data derived from very few studies. The Indian Council of Medical Research–India Diabetes (ICMR–INDIAB) study is a community-based survey conceived with the aim of obtaining the prevalence rates of diabetes in India as a whole, covering all 28 states, the National Capital Territory of Delhi, and two of the union territories in the mainland of India, with a total sample size of 124,000 individuals. Methods A stratified multistage sampling design has been used. In all study subjects, a structured questionnaire was administered and anthropometric parameters and blood pressure were measured. Fasting capillary blood glucose was first determined using a glucose meter. An oral glucose load was then administered to all subjects except those with self-reported diabetes, and the 2 h post-load capillary blood glucose was estimated. In every fifth subject, a fasting venous sample was collected for measurement of lipids and creatinine, a resting 12-lead electrocardiogram was performed, and dietary assessment questionnaire was administered. In all diabetic subjects, an additional diabetes questionnaire was used and a fasting venous sample drawn for glycated hemoglobin. Results All biological samples collected were analyzed in a central laboratory. All data collected were stored electronically. Quality control was achieved through multiple tiers of checks. Conclusions The ICMR–INDIAB study is the first of its kind attempting to provide accurate and comprehensive state- and national-level data on diabetes prevalence in India. PMID:21880233

  7. Polonium-210 and Caesium-137 in lynx (Lynx lynx), wolverine (Gulo gulo) and wolves (Canis lupus).

    PubMed

    Gjelsvik, Runhild; Holm, Elis; Kålås, John Atle; Persson, Bertil; Asbrink, Jessica

    2014-12-01

    Wolves, lynx and wolverines are on the top of the food-chain in northern Scandinavia and Finland. (210)Po and (137)Cs have been analysed in samples of liver, kidney and muscle from 28 wolves from Sweden. In addition blood samples were taken from 27 wolves. In 9 of the wolves, samples of muscle, liver and blood were analysed for (210)Po. Samples of liver and muscle were collected from 16 lynx and 16 wolverines from Norway. The liver samples were analysed for (210)Po and (137)Cs. Only (137)Cs analyses were carried out for the muscle samples. The wolves were collected during the winter 2010 and 2011, while the samples for lynx and wolverines were all from 2011. The activity concentrations of (210)Po in wolves were higher for liver (range 20-523 Bq kg(-1) d.w.) and kidney (range 24-942 Bq kg(-1) d.w.) than muscle (range 1-43 Bq kg(-1) d.w.) and blood (range 2-54 Bq kg(-1) d.w.). Activity ratios, (210)Po/(210)Pb, in wolf samples of muscle, liver and blood were in the ranges 2-77, 9-56 and 2-54. Using a wet weight ratio of 3.8 the maximal absorbed dose from (210)Po to wolf liver was estimated to 3500 μGy per year. Compared to wolf, the ranges of (210)Po in liver samples were lower in lynx (range 22-211 Bq kg(-1) d.w.) and wolverine (range16-160 Bq kg(-1) d.w.). Concentration of (137)Cs in wolf samples of muscle, liver, kidney and blood were in the ranges 70-8410 Bq kg(-1) d.w., 36-4050 Bq kg(-1) d.w., 31-3453 Bq kg(-1) d.w. and 4-959 Bq kg(-1) d.w., respectively. (137)Cs in lynx muscle and liver samples were in the ranges 44-13393 Bq kg(-1) d.w. and 125-10260 Bq kg(-1) d.w. The corresponding values for (137)Cs in wolverine were 22-3405 Bq kg(-1) d.w. for liver and 53-4780 Bq kg(-1) d.w. for muscle. The maximal absorbed dose from (137)Cs to lynx was estimated to 3000 μGy per year. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. A multiplex nested PCR for the detection and identification of Candida species in blood samples of critically ill paediatric patients

    PubMed Central

    2014-01-01

    Background Nosocomial candidaemia is associated with high mortality rates in critically ill paediatric patients; thus, the early detection and identification of the infectious agent is crucial for successful medical intervention. The PCR-based techniques have significantly increased the detection of Candida species in bloodstream infections. In this study, a multiplex nested PCR approach was developed for candidaemia detection in neonatal and paediatric intensive care patients. Methods DNA samples from the blood of 54 neonates and children hospitalised in intensive care units with suspected candidaemia were evaluated by multiplex nested PCR with specific primers designed to identify seven Candida species, and the results were compared with those obtained from blood cultures. Results The multiplex nested PCR had a detection limit of four Candida genomes/mL of blood for all Candida species. Blood cultures were positive in 14.8% of patients, whereas the multiplex nested PCR was positive in 24.0% of patients, including all culture-positive patients. The results obtained with the molecular technique were available within 24 hours, and the assay was able to identify Candida species with 100% of concordance with blood cultures. Additionally, the multiplex nested PCR detected dual candidaemia in three patients. Conclusions Our proposed PCR method may represent an effective tool for the detection and identification of Candida species in the context of candidaemia diagnosis in children, showing highly sensitive detection and the ability to identify the major species involved in this infection. PMID:25047415

  9. A multiplex nested PCR for the detection and identification of Candida species in blood samples of critically ill paediatric patients.

    PubMed

    Taira, Cleison Ledesma; Okay, Thelma Suely; Delgado, Artur Figueiredo; Ceccon, Maria Esther Jurfest Rivero; de Almeida, Margarete Teresa Gottardo; Del Negro, Gilda Maria Barbaro

    2014-07-21

    Nosocomial candidaemia is associated with high mortality rates in critically ill paediatric patients; thus, the early detection and identification of the infectious agent is crucial for successful medical intervention. The PCR-based techniques have significantly increased the detection of Candida species in bloodstream infections. In this study, a multiplex nested PCR approach was developed for candidaemia detection in neonatal and paediatric intensive care patients. DNA samples from the blood of 54 neonates and children hospitalised in intensive care units with suspected candidaemia were evaluated by multiplex nested PCR with specific primers designed to identify seven Candida species, and the results were compared with those obtained from blood cultures. The multiplex nested PCR had a detection limit of four Candida genomes/mL of blood for all Candida species. Blood cultures were positive in 14.8% of patients, whereas the multiplex nested PCR was positive in 24.0% of patients, including all culture-positive patients. The results obtained with the molecular technique were available within 24 hours, and the assay was able to identify Candida species with 100% of concordance with blood cultures. Additionally, the multiplex nested PCR detected dual candidaemia in three patients. Our proposed PCR method may represent an effective tool for the detection and identification of Candida species in the context of candidaemia diagnosis in children, showing highly sensitive detection and the ability to identify the major species involved in this infection.

  10. Bi-phasic trends in mercury concentrations in blood of Wisconsin common loons during 1992–2010

    USGS Publications Warehouse

    Meyer, Michael W.; Rasmussen, Paul W.; Watras, Carl J.; Fevold, Brick M.; Kenow, Kevin P.

    2011-01-01

    Wisconsin Department of Natural Resources (WDNR) assessed the ecological risk of mercury (Hg) in aquatic systems by monitoring common loon (Gavia immer) population dynamics and blood Hg concentrations. We report temporal trends in blood Hg concentrations based on 334 samples collected from adults recaptured in subsequent years (resampled 2-9 times) and from 421 blood samples of chicks collected at lakes resampled 2-8 times 1992-2010.. Temporal trends were identified with generalized additive mixed effects models (GAMMs) and mixed effects models to account for the potential lack of independence among observations from the same loon or same lake. Trend analyses indicated that Hg concentrations in the blood of Wisconsin loons declined over the period 1992-2000, and increased during 2002-2010, but not to the level observed in the early 1990s. The best fitting linear mixed effects model included separate trends for the two time periods. The estimated trend in Hg concentration among the adult loon population during 1992-2000 was -2.6% per year and the estimated trend during 2002-2010 was +1.8% per year; chick blood Hg concentrations decreased by -6.5% per year during 1992-2000, but increased 1.8% per year during 2002-2010. This bi-phasic pattern is similar to trends observed for concentrations of methylmercury (meHg) and SO4 in lake water of a well studied seepage lake (Little Rock Lake, Vilas County) within our study area. A cause-effect relationship between these independent trends is hypothesized.

  11. Presence of infective Epstein-Barr virus in the urine of patients with infectious mononucleosis.

    PubMed

    Landau, Z; Gross, R; Sanilevich, A; Friedmann, A; Mitrani-Rosenbaum, S

    1994-11-01

    The presence of Epstein-Barr virus (EBV) in the blood and urine of 20 patients with infectious mononucleosis (IM) was investigated together with the clinical course of the disease, and in 9 patients up to 2-7 months after recovery. EBV DNA, analyzed by the polymerase chain reaction (PCR), was detected in the blood of all 20 patients from the first sample obtained and detected between 3 to 42 days from the beginning of symptoms and up to 2-3 months after recovery. In the urine, EBV DNA was detected in 15 out of 16 (93%) patients in the first sample obtained and detected between 3 to 50 days during the clinical course of the disease. In four patients EBV DNA was detected in the urine up to 3 months after full recovery. Seventeen out of 26 (65%) urine samples including 3 which were obtained 2-7 months after recovery infected B cells as assessed by PCR. Nine out of 12 (75%) urine samples tested induced Epstein-Barr nuclear antigen (EBNA) in the infected B-cell line. In addition to the persistence of EBV in the blood of IM patients, these studies show for the first time the presence of infective EBV in the urine during the clinical course of the disease and up to 7 months after full clinical recovery.

  12. [Comparison of MPure-12 Automatic Nucleic Acid Purification and Chelex-100 Method].

    PubMed

    Shen, X; Li, M; Wang, Y L; Chen, Y L; Lin, Y; Zhao, Z M; Que, T Z

    2017-04-01

    To explore the forensic application value of MPure-12 automatic nucleic acid purification (MPure-12 Method) for DNA extraction by extracting and typing DNA from bloodstains and various kinds of biological samples with different DNA contents. Nine types of biological samples, such as bloodstains, semen stains, and saliva were collected. DNA were extracted using MPure-12 method and Chelex-100 method, followed by PCR amplification and electrophoresis for obtaining STR-profiles. The samples such as hair root, chutty, butt, muscular tissue, saliva stain, bloodstain and semen stain were typed successfully by MPure-12 method. Partial alleles were lacked in the samples of saliva, and the genotyping of contact swabs was unsatisfactory. Additional, all of the bloodstains (20 μL, 15 μL, 10 μL, 5 μL, 1 μL) showed good typing results using Chelex-100 method. But the loss of alleles occurred in 1 μL blood volume by MPure-12 method. MPure-12 method is suitable for DNA extraction of a certain concentration blood samples.Chelex-100 method may be better for the extraction of trace blood samples.This instrument used in nucleic acid extraction has the advantages of simplicity of operator, rapidity, high extraction efficiency, high rate of reportable STR-profiles and lower man-made pollution. Copyright© by the Editorial Department of Journal of Forensic Medicine

  13. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  14. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace.

    PubMed

    East, Christine E; Leader, Leo R; Sheehan, Penelope; Henshall, Naomi E; Colditz, Paul B; Lau, Rosalind

    2015-05-01

    Fetal scalp blood sampling for lactate estimation may be considered following identification of an abnormal or non-reassuring fetal heart rate pattern. The smaller volume of blood required for this test, compared with the more traditional pH estimation, may improve sampling rates. The appropriate use of this practice mandates systematic review of its safety and clinical effectiveness prior to widespread introduction. To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal well-being during labour, compared with no testing or alternative testing. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2015). All published and unpublished randomised and quasi-randomised trials that compared fetal scalp lactate testing with no testing or alternative testing to evaluate fetal status in the presence of a non-reassuring cardiotocograph during labour. We used the standard methodological procedures of the Cochrane Pregnancy and Childbirth Group. Two review authors independently assessed the studies. The search identified two completed randomised controlled trials (RCTs) and two ongoing trials. The two published RCTs considered outcomes for 3348 mother-baby pairs allocated to either lactate or pH estimation of fetal blood samples when clinically indicated in labour. Overall, the published RCTs were of low or unclear risk of bias. There was a high risk of performance bias, because it would not have been feasible to blind clinicians or participants.No statistically significant between-group differences were found for neonatal encephalopathy (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.32 to 3.09, one study, 2992 infants) or death. No studies reported neonatal seizures. We had planned to report death with other morbidities, for example, neonatal encephalopathy; however, the data were not available in a format suitable for this, therefore death due to congenital abnormality was considered alone. The three reported neonatal deaths occurred in babies with diaphragmatic hernias (n = 2) or congenital cardiac fibrosis (n = 1). All three babies had been randomised to the pH group and were not acidaemic at birth.There were no statistically significant differences for any of the pre-specified secondary fetal/neonatal/infant outcomes for which data were available. This included low Apgar score at five minutes (RR 1.13, 95% CI 0.76 to 1.68, two studies, 3319 infants) and admission to neonatal intensive care units (RR 1.02, 95% CI 0.83 to 1.25, one study, 2992 infants), or metabolic acidaemia (RR 0.91, 95% CI 0.60 to 1.36, one study, 2675 infants) considered within the studies, either overall or where data were available for those where fetal blood sampling had occurred within 60 minutes of delivery.Similar proportions of fetuses underwent additional tests to further evaluate well-being during labour, including scalp pH if in the lactate group or scalp lactate if in the pH group (RR 0.22, 95% CI 0.04 to 1.30, two studies, 3333 infants;Tau² 1.00, I² = 58%). Fetal blood sampling attempts for lactate and pH estimation were successful in 98.7% and 79.4% of procedures respectively in the one study that reported this outcome.There were no significant between-group differences in mode of birth or operative birth for non-reassuring fetal status, either for all women, or within the group where the fetal blood sample had been taken within 60 minutes of delivery (for example, caesarean section for all enrolled, RR 1.09, 95% CI 0.97 to 1.22, two studies, 3319 women; operative delivery for non-reassuring fetal status for all enrolled RR 1.02, 95% CI 0.93 to 1.11, one study, 2992 women).Neither study reported on adverse effects of fetal scalp lacerations or maternal anxiety. When further testing to assess fetal well-being in labour is indicated, fetal scalp blood lactate estimation is more likely to be successfully undertaken than pH estimation. Further studies may consider subgroup analysis by gestational age, the stage of labour and sampling within a prolonged second stage of labour. Additionally, we await the findings from the ongoing studies that compare allocation to no fetal blood sample with sampling for lactate and address longer-term neonatal outcomes, maternal satisfaction with intrapartum fetal monitoring and an economic analysis.

  15. Antibodies against canine parvovirus of wolves of Minnesota: A serologic study from 1975 through 1985

    USGS Publications Warehouse

    Goyal, S.M.; Mech, L.D.; Rademacher, R.A.; Khan, M.A.; Seal, U.S.

    1986-01-01

    Serum samples (n = 137) from 47 wild wolves (Canis lupus; 21 pups and 26 adults) were evaluated from 1975 to 1985 for antibodies against canine parvovirus, using the hemagglutination inhibition (HI) test. In addition, several blood samples (n = 35) from 14 of these wolves (6 pups and 8 adults) were evaluated simultaneously for erythrocyte and leukocyte counts, and for hemoglobin and blood urea nitrogen concentrations. Sixty-nine (50%) of the serum samples (35 wolves) had HI titers of greater than or equal to 256, whereas 68 (50%) of the samples (16 wolves) had HI titers of less than or equal to 128. Significant differences in the geometric mean titers were not found between pups and adults or between males and females. Of the 47 wolves evaluated, 12 (25%) developed a greater than or equal to fourfold increase in antibody titers during the 11-year period, with 2 wolves developing serologic conversions in 1976. The data indicate that canine parvovirus may have begun infecting wolves before or at the same time that it began infecting the dog population in the United States.

  16. Treatment of carprofen overdose with therapeutic plasma exchange in a dog.

    PubMed

    Kjaergaard, Astrid B; Davis, Jennifer L; Acierno, Mark J

    2018-06-13

    To report the use of therapeutic plasma exchange (TPE) in a dog with carprofen toxicosis. A 6-year-old female neutered Bichon Frise weighing 6.9 kg was examined after it had ingested 72 mg/kg carprofen. Mild dehydration without azotemia and with a urine specific gravity of 1.050 was noted at presentation. Treatment consisted of induction of emesis, symptomatic medical therapy, and TPE. The TPE achieved 1.5 plasma volume exchanges over 3 hours. Blood samples and effluent samples were collected every 30 minutes during TPE and additional blood samples were collected 11 and 35 hours after treatment. Carprofen concentrations in these samples were determined by high-pressure liquid chromatography. A 51% reduction in serum carprofen concentration was achieved following TPE. This report describes the successful reduction of plasma carprofen concentration in a dog using TPE. Although recent studies suggest that this particular dog may not have received a toxic dose, a 51% reduction of plasma carprofen concentration was achieved over 180 minutes, and TPE may be beneficial for treatment of dogs that have ingested higher doses. © Veterinary Emergency and Critical Care Society 2018.

  17. Serologic survey of domestic felids in the Petén region of Guatemala.

    PubMed

    Lickey, Adrienne L A; Kennedy, Melissa; Patton, Sharon; Ramsay, Edward C

    2005-03-01

    Blood samples were analyzed from 30 domestic cats (Felis domesticus) from the Petén region of Guatemala to determine the seroprevalence of common pathogens that may pose a potential risk to native wild felids. Eight of the cats had been vaccinated previously; however, owners were unable to fully describe the type of vaccine and date of administration. In addition, blood samples were obtained from two captive margays (Leopardus wiedii). Samples were tested for antibodies to feline immunodeficiency virus, Dirofilaria immitis, feline panleukopenia virus, feline herpesvirus, feline coronavirus, canine distemper virus, and Toxoplasma gondii and for feline leukemia virus (FeLV) antigen. Fifty percent or more of the cats sampled were seropositive for feline herpesvirus (22 of 30), feline panleukopenia (15 of 30), and T. gondii (16 of 30). Five cats were positive for FeLV antigen. Both margays were seropositive for feline coronavirus and one was strongly seropositive to T. gondii. All animals were seronegative for D. immitis. This survey provides preliminary information about feline diseases endemic to the Petén region.

  18. Rapid and effective processing of blood specimens for diagnostic PCR using filter paper and Chelex-100.

    PubMed Central

    Polski, J M; Kimzey, S; Percival, R W; Grosso, L E

    1998-01-01

    AIM: To provide a more efficient method for isolating DNA from peripheral blood for use in diagnostic DNA mutation analysis. METHODS: The use of blood impregnated filter paper and Chelex-100 in DNA isolation was evaluated and compared with standard DNA isolation techniques. RESULTS: In polymerase chain reaction (PCR) based assays of five point mutations, identical results were obtained with DNA isolated routinely from peripheral blood and isolated using the filter paper and Chelex-100 method. CONCLUSION: In the clinical setting, this method provides a useful alternative to conventional DNA isolation. It is easily implemented and inexpensive, and provides sufficient, stable DNA for multiple assays. The potential for specimen contamination is reduced because most of the steps are performed in a single microcentrifuge tube. In addition, this method provides for easy storage and transport of samples from the point of acquisition. PMID:9893748

  19. Rapid and effective processing of blood specimens for diagnostic PCR using filter paper and Chelex-100.

    PubMed

    Polski, J M; Kimzey, S; Percival, R W; Grosso, L E

    1998-08-01

    To provide a more efficient method for isolating DNA from peripheral blood for use in diagnostic DNA mutation analysis. The use of blood impregnated filter paper and Chelex-100 in DNA isolation was evaluated and compared with standard DNA isolation techniques. In polymerase chain reaction (PCR) based assays of five point mutations, identical results were obtained with DNA isolated routinely from peripheral blood and isolated using the filter paper and Chelex-100 method. In the clinical setting, this method provides a useful alternative to conventional DNA isolation. It is easily implemented and inexpensive, and provides sufficient, stable DNA for multiple assays. The potential for specimen contamination is reduced because most of the steps are performed in a single microcentrifuge tube. In addition, this method provides for easy storage and transport of samples from the point of acquisition.

  20. Data characterizing diurnal rhythms in the number of peripheral CD8α- and CD8α+ γδ T cells in domestic pigs.

    PubMed

    Engert, Larissa C; Weiler, Ulrike; Stefanski, Volker; Schmucker, Sonja S

    2018-02-01

    This data article is related to the original research article "Diurnal rhythms in peripheral blood immune cell numbers of domestic pigs" of Engert et al. [1] and describes diurnal rhythms in the number of CD8α - and CD8α + γδ T cells in peripheral blood of domestic pigs. Blood samples were taken from 18 animals over periods of up to 50 h and immune cell subtypes were determined by flow cytometry. Diurnal rhythmicity of cell numbers of γδ T cell subtypes was analyzed with cosinor analysis and different properties of rhythmicity (mesor, amplitude, and peak time) were calculated. In addition, associations between cell numbers of the investigated cell types in porcine blood with plasma cortisol concentration, hematocrit, and experimental conditions were identified with linear mixed model analysis.

  1. Blood Glucose Measurement in the Intensive Care Unit: What Is the Best Method?

    PubMed Central

    Le, Huong T.; Harris, Neil S.; Estilong, Abby J.; Olson, Arvid; Rice, Mark J.

    2013-01-01

    Abnormal glucose measurements are common among intensive care unit (ICU) patients for numerous reasons and hypoglycemia is especially dangerous because these patients are often sedated and unable to relate the associated symptoms. Additionally, wide swings in blood glucose have been closely tied to increased mortality. Therefore, accurate and timely glucose measurement in this population is critical. Clinicians have several choices available to assess blood glucose values in the ICU, including central laboratory devices, blood gas analyzers, and point-of-care meters. In this review, the method of glucose measurement will be reviewed for each device, and the important characteristics, including accuracy, cost, speed of result, and sample volume, will be reviewed, specifically as these are used in the ICU environment. Following evaluation of the individual measurement devices and after considering the many features of each, recommendations are made for optimal ICU glucose determination. PMID:23567008

  2. Broad-Range 16S rDNA PCR on Heart Valves in Infective Endocarditis.

    PubMed

    Müller Premru, Manica; Lejko Zupanc, Tatjana; Klokočovnik, Tomislav; Ruzić Sabljić, Eva; Cerar, Tjaša

    2016-03-01

    Infective endocarditis (IE) is diagnosed by blood and/or resected valve cultivation and echocardiographic findings, as defined by the Duke criteria. Unfortunately, cultures may be negative due to prior antibiotic therapy or fastidious or slow-growing microorganisms. The study aim was to investigate the value of the broad-range polymerase chain reaction (PCR) in addition to blood and valve culture for the detection of causative microorganisms. Between February 2012 and March 2015, valve samples from 36 patients undergoing cardiac surgery were analyzed; of these patients, 26 had a preoperative diagnosis of IE and 10 served as controls. Multiple blood cultures were obtained from 34 patients before antibiotic therapy was commenced. Valve samples were inoculated on bacteriological media and underwent analysis using broad-range PCR (16S rDNA). IE was confirmed microbiologically in 21 of the 26 patients (80.7%); in 20 cases (76.9%) this was by positive blood cultures and in 16 (61.5%) by positive valves. Valves were positive in 15 blood culturepositive patients, and in one blood-culture negative patient. Broad-range PCR detected a microorganism in valves significantly more frequently (n = 14; 53.8%) compared to valve culture (n = 8; 30.7%) (chisquare 11.5, p <0.001). The predominant microorganisms were Staphylococcus aureus, Streptococcus of the viridans group, coagulasenegative staphylococci and Enterococcus faecalis. Blood, valve cultures and broad-range PCR were negative in five patients (19.3%) with IE, and in all 10 subjects of the control group. Broad-range PCR on valves was more sensitive than valve culture. However, blood culture, if taken before the start of antibiotic therapy, was the best method for detecting IE.

  3. Impact of a Dietary Supplement Containing 1,3-Dimethylamylamine on Blood Pressure and Bloodborne Markers of Health: a 10-Week Intervention Study

    PubMed Central

    Whitehead, Paul N.; Schilling, Brian K.; Farney, Tyler M.; Bloomer, Richard J.

    2012-01-01

    Background: 1,3-dimethylamylamine is a commonly used ingredient within dietary supplements. Our prior work with this agent indicates a transient increase in blood pressure (systolic in particular) following oral ingestion of a single dosage, but no significant increase in resting blood pressure following chronic ingestion. Moreover, intervention studies involving both two and eight weeks of treatment with finished products containing 1,3-dimethylamylamine indicate minimal or no change in bloodborne markers of health. The present study sought to extend these findings by using a 10-week intervention trial to determine the change in selected markers of health in a sample of men. Methods: 25 healthy men were randomly assigned to either a placebo (n = 13) or to a supplement containing 1,3-dimethylamylamine (n = 12) for a period of 10 weeks. Before and after the intervention, resting blood pressure and heart rate were measured, and blood samples were collected for determination of complete blood count, metabolic panel, and lipid panel. Results: No significant differences were noted between conditions for blood pressure (P > 0.05), although systolic blood pressure increased approximately 6 mmHg with the supplement (diastolic blood pressure decreased approximately 4 mmHg). A main effect for time was noted for heart rate (P = 0.016), with values decreasing from pre to post intervention. There were significant main effects for time for creatinine (increased from pre to post intervention; P = 0.043) and alkaline phosphatase (decreased from pre to post intervention; P = 0.009), with no condition differences noted (P > 0.05). There was a significant interaction noted for low density lipoprotein cholesterol (LDL-C) (P = 0.043), with values decreasing in the supplement group from pre to post intervention approximately 7 mg · dL−1 (P = 0.034). No other effects of significance were noted for bloodborne variables. Conclusion: These data indicate that a dietary supplement containing 1,3-dimethylamylamine does not result in a statistically significant increase in resting heart rate or blood pressure (although systolic blood pressure is increased ∼6 mmHg with supplement use). The supplement does not negatively impact bloodborne markers of health. Further study is needed involving a longer intervention period, a larger sample size, and additional measures of health and safety. PMID:23882146

  4. Liquid Biopsy: A Future Tool for Posttreatment Surveillance in Head and Neck Cancer?

    PubMed

    van Ginkel, Joost H; Huibers, Manon M H; Noorlag, Rob; de Bree, Remco; van Es, Robert J J; Willems, Stefan M

    2017-01-01

    The prognosis of head and neck squamous cell carcinoma (HNSCC) is largely based on disease stage. Despite improvements in treatment, recurrence rates are still considered high. Currently, disease progression or regression after curative treatment is monitored by clinical evaluation combined with flexible endoscopy and/or imaging. However, specificity of imaging is low due to the posttreatment effects. Detection of circulating tumor DNA (ctDNA) from blood samples of HNSCC patients is a minimally invasive technique that could lead to an earlier detection of recurrence. In addition, digital droplet PCR (ddPCR) could be used to sensitively detect these mutational targets. Future study on ctDNA using ddPCR in blood samples of HNSCC patients is recommended during the follow-up stage to detect recurrences in a timely manner. © 2016 S. Karger AG, Basel.

  5. Immunocapture and microplate-based activity and quantity measurement of pyruvate dehydrogenase in human peripheral blood mononuclear cells

    PubMed Central

    Liu, Xiaowen; Pervez, Hira; Andersen, Lars W; Uber, Amy; Montissol, Sophia; Patel, Parth; Donnino, Michael W

    2015-01-01

    Background Pyruvate dehydrogenase (PDH) activity is altered in many human disorders. Current methods require tissue samples and yield inconsistent results. We describe a modified method for measuring PDH activity from isolated human peripheral blood mononuclear cells (PBMCs). Results/Methodology We found that PDH activity and quantity can be successfully measured in human PBMCs. Freeze-thaw cycles cannot efficiently disrupt the mitochondrial membrane. Processing time of up to 20 h does not affect PDH activity with proteinase inhibitor addition and a detergent concentration of 3.3% showed maximum yield. Sample protein concentration is correlated to PDH activity and quantity in human PBMCs from healthy subjects. Conclusion Measuring PDH activity from PBMCs is a novel, easy and less invasive way to further understand the role of PDH in human disease. PMID:25826140

  6. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros

    PubMed Central

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N.; Payne, Junaidi

    2013-01-01

    Objective To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Methods Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA® blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. Results BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. Conclusions This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases. PMID:23593586

  7. A rabbit model of non-typhoidal Salmonella bacteremia.

    PubMed

    Panda, Aruna; Tatarov, Ivan; Masek, Billie Jo; Hardick, Justin; Crusan, Annabelle; Wakefield, Teresa; Carroll, Karen; Yang, Samuel; Hsieh, Yu-Hsiang; Lipsky, Michael M; McLeod, Charles G; Levine, Myron M; Rothman, Richard E; Gaydos, Charlotte A; DeTolla, Louis J

    2014-09-01

    Bacteremia is an important cause of morbidity and mortality in humans. In this study, we focused on the development of an animal model of bacteremia induced by non-typhoidal Salmonella. New Zealand White rabbits were inoculated with a human isolate of non-typhoidal Salmonella strain CVD J73 via the intra-peritoneal route. Blood samples were collected at specific time points and at euthanasia from infected rabbits. Additionally, tissue samples from the heart, lungs, spleen, gastrointestinal tract, liver and kidneys were obtained at euthanasia. All experimentally infected rabbits displayed clinical signs of disease (fever, dehydration, weight loss and lethargy). Tissues collected at necropsy from the animals exhibited histopathological changes indicative of bacteremia. Non-typhoidal Salmonella bacteria were detected in the blood and tissue samples of infected rabbits by microbiological culture and real-time PCR assays. The development of this animal model of bacteremia could prove to be a useful tool for studying how non-typhoidal Salmonella infections disseminate and spread in humans. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. [Logistics of collection and transportation of biological samples and the organization of the central laboratory in the ELSA-Brasil].

    PubMed

    Fedeli, Ligia G; Vidigal, Pedro G; Leite, Claudia Mendes; Castilhos, Cristina D; Pimentel, Robércia Anjos; Maniero, Viviane C; Mill, Jose Geraldo; Lotufo, Paulo A; Pereira, Alexandre C; Bensenor, Isabela M

    2013-06-01

    The ELSA (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a multicenter cohort study which aims at the identification of risk factors associated with type 2 diabetes and cardiovascular diseases in the Brazilian population. The paper describes the strategies for the collection, processing, transportation, and quality control of blood and urine tests in the ELSA. The study decided to centralize the tests at one single laboratory. The processing of the samples was performed at the local laboratories, reducing the weight of the material to be transported, and diminishing the costs of transportation to the central laboratory at the Universidade de São Paulo Hospital. The study included tests for the evaluation of diabetes, insulin resistance, dyslipidemia, electrolyte abnormalities, thyroid hormones, uric acid, hepatic enzyme abnormalities, inflammation, and total blood cell count. In addition, leukocyte DNA, urine, plasma and serum samples were stored. The central laboratory performed approximately 375,000 tests.

  9. Effect of ascorbic acid on storage of Greyhound erythrocytes.

    PubMed

    Fontes, Jorge A; Banerjee, Uddyalok; Iazbik, M Cristina; Marín, Liliana M; Couto, C Guillermo; Palmer, Andre F

    2015-09-01

    To assess changes in biochemical and biophysical properties of canine RBCs during cold (1° to 6°C) storage in a licensed RBC additive solution (the RBC preservation solution designated AS-1) supplemented with ascorbic acid. Blood samples from 7 neutered male Greyhounds; all dogs had negative results when tested for dog erythrocyte antigen 1.1. Blood was collected into citrate-phosphate-dextrose and stored in AS-1. Stored RBCs were supplemented with 7.1mM ascorbic acid or with saline (0.9% NaCl) solution (control samples). Several biochemical and biophysical properties of RBCs were measured, including percentage hemolysis, oxygen-hemoglobin equilibrium, and the kinetic rate constants for O2 dissociation, carbon monoxide association, and nitric oxide dioxygenation. Greyhound RBCs stored in AS-1 supplemented with ascorbic acid did not have significantly decreased hemolysis, compared with results for the control samples, during the storage period. In this study, ascorbic acid did not reduce hemolysis during storage. Several changes in stored canine RBCs were identified as part of the hypothermic storage lesion.

  10. Effects of cryopreservation on microbial-contaminated cord blood.

    PubMed

    Clark, Pamela; Trickett, Annette; Saffo, Sandra; Stark, Damien

    2014-03-01

    Cord blood units (CBUs) are associated with significant risk of exposure to microbial contamination during collection and processing; however, the survival of bacteria within a CBU is poorly understood. This study aimed to determine whether contaminating organisms in CBU survive the cryopreservation, frozen storage, and subsequent thawing conditions before infusion. A total of 134 CBUs rejected from banking due to known contamination were thawed and rescreened using blood culture bottles (BacT/ALERT, bioMérieux). An additional 61 fresh CBUs were deliberately spiked with a range of microbial organisms and evaluated both before freeze and after thaw. Microbial contaminants were detected after thaw in 63% of stored contaminated CBUs and 85% of spiked CBUs. Postthaw organism detection in spiked cord blood (CB) was higher in adult culture bottles (80%) than pediatric culture bottles (61%). Twenty percent of spiked organisms, particularly Bacillus subtilis, Escherichia coli, Clostridium sporogenes, and Propionibacterium acnes, were not detected in prefreeze samples but were detectable after thaw. This study demonstrates that the majority of contaminating organisms isolated in a prefreeze sample of CB have the ability to survive cryopreservation, frozen storage, and thawing. Further, CBUs reported as microbial free may contain microbial contamination, which could result in transplantation of contaminated CB and be potentially deleterious to a patient. © 2013 The Sydney Children's Hospital Network. Transfusion © 2013 American Association of Blood Banks.

  11. Polarized Raman spectroscopic characterization of normal and oral cancer blood plasma

    NASA Astrophysics Data System (ADS)

    Pachaiappan, Rekha; Prakasarao, Aruna; Singaravelu, Ganesan

    2017-02-01

    In India oral cancer ranks the top due to the habitual usage of tobacco in its various forms and remains the major burden. Hence priority is given for early diagnosis as it is the better solution for cure or to improve the survival rate. For the past three decades, optical spectroscopic techniques have shown its capacity in the discrimination of normal and malignant samples. Many research works have conventional Raman in the effective detection of cancer using the variations in bond vibrations of the molecules. However in addition polarized Raman provides the orientation and symmetry of biomolecules. If so can polarized Raman be the better choice than the conventional Raman in the detection of cancer? The present study aimed to found the answer for the above query. The conventional and polarized Raman spectra were acquired for the same set of blood plasma samples of normal subjects and oral malignant (OSCC) patients. Thus, obtained Raman spectral data were compared using linear discriminant analysis coupled with artificial neural network (LDA-ANN). The depolarization ratio of biomolecules such as antioxidant, amino acid, protein and nucleic acid bases present in blood plasma was proven to be the best attributes in the categorization of the groups. The polarized Raman results were promising in discriminating oral cancer blood plasma from that of normal blood plasma with improved efficiency. The results will be discussed in detail.

  12. Molt-associated changes in hematologic and plasma biochemical values and stress hormone levels in African penguins (Spheniscus demersus).

    PubMed

    Mazzaro, Lisa M; Meegan, Jenny; Sarran, Delphine; Romano, Tracy A; Bonato, Vinicius; Deng, Shibing; Dunn, J Lawrence

    2013-12-01

    Handling, including blood collection, has often been discouraged in molting penguins because it is considered an additional stress imposed on birds already experiencing major physiologic stress associated with molting. To evaluate the degree of physiologic stress posed by molting, we compared the hematologic and plasma biochemical values and hormone levels of molting and nonmolting African penguins, Spheniscus demersus. Five male and 5 female penguins randomly chosen were given complete physical examinations, were weighed, and blood samples were taken at 7 time points before, during, and after the molt. Data were analyzed by linear mixed-model analysis of variance. Throughout the study, behavior and appetite remained normal. Catecholamine levels were highly variable within and among subjects, whereas mean corticosterone levels were significantly different between baseline, molt, and postmolt values. Significant differences from baseline values were observed in many of the hematologic analytes; however, only decreases in hematocrit and red blood cell count values were considered clinically significant. Anemia due to experimentally induced blood loss as a possible cause of the significant hematologic changes was ruled out based on results of a follow-up control study during the nonmolt season, which showed no significant changes in hematocrit level or total red blood cell counts when using similar sampling protocols, which indicates that these changes were associated with molt.

  13. A healthy volunteer study to investigate trace element contamination of blood samples by stainless steel venepuncture needles.

    PubMed

    Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D

    2012-02-01

    The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.

  14. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  15. 77 FR 37445 - Notice of Permit Modification Received Under the Antarctic Conservation Act of 1978 (Pub. L. 95-541)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... depth, swim speed, ambient temperature, and light levels, stomach temperature, heat flux and skin temperature. An additional stroke frequency sensor is glued to the base of the tail. These tests and... photogrammetric models and infrared analysis and ultrasound measurements of blubber depth, collect blood samples...

  16. Evaluation of red blood cell and platelet antigen genotyping platforms (ID CORE XT/ID HPA XT) in routine clinical practice.

    PubMed

    Finning, Kirstin; Bhandari, Radhika; Sellers, Fiona; Revelli, Nicoletta; Villa, Maria Antonietta; Muñiz-Díaz, Eduardo; Nogués, Núria

    2016-03-01

    High-throughput genotyping platforms enable simultaneous analysis of multiple polymorphisms for blood group typing. BLOODchip® ID is a genotyping platform based on Luminex® xMAP technology for simultaneous determination of 37 red blood cell (RBC) antigens (ID CORE XT) and 18 human platelet antigens (HPA) (ID HPA XT) using the BIDS XT software. In this international multicentre study, the performance of ID CORE XT and ID HPA XT, using the centres' current genotyping methods as the reference for comparison, and the usability and practicality of these systems, were evaluated under working laboratory conditions. DNA was extracted from whole blood in EDTA with Qiagen methodologies. Ninety-six previously phenotyped/genotyped samples were processed per assay: 87 testing samples plus five positive controls and four negative controls. Results were available for 519 samples: 258 with ID CORE XT and 261 with ID HPA XT. There were three "no calls" that were either caused by human error or resolved after repeating the test. Agreement between the tests and reference methods was 99.94% for ID CORE XT (9,540/9,546 antigens determined) and 100% for ID HPA XT (all 4,698 alleles determined). There were six discrepancies in antigen results in five RBC samples, four of which (in VS, N, S and Do(a)) could not be investigated due to lack of sufficient sample to perform additional tests and two of which (in S and C) were resolved in favour of ID CORE XT (100% accuracy). The total hands-on time was 28-41 minutes for a batch of 16 samples. Compared with the reference platforms, ID CORE XT and ID HPA XT were considered simpler to use and had shorter processing times. ID CORE XT and ID HPA XT genotyping platforms for RBC and platelet systems were accurate and user-friendly in working laboratory settings.

  17. Infrared Spectroscopy of Blood for Disease Identification

    NASA Astrophysics Data System (ADS)

    Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.

    2003-09-01

    Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.

  18. The positive effects of different platelet-rich plasma methods on human muscle, bone, and tendon cells.

    PubMed

    Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Dugdale, Evan M; Hansen, Derek; Cote, Mark P; Bradley, James P; Romeo, Anthony A; Arciero, Robert A; Beitzel, Knut

    2012-08-01

    Clinical application of platelet-rich plasma (PRP) in the realm of orthopaedic sports medicine has yielded variable results. Differences in separation methods and variability of the individual may contribute to these variable results. To compare the effects of different PRP separation methods on human bone, muscle, and tendon cells in an in vitro model. Controlled laboratory study. Blood collected from 8 participants (mean ± SD age 31.6 ± 10.9 years) was used to obtain PRP preparations. Three different PRP separation methods were used: a single-spin process yielding a lower platelet concentration (PRP(LP)), a single-spin process yielding high platelet and white blood cell concentrations (PRP(HP)), and a double-spin that produces a higher platelet concentration and lower white blood cell concentration (PRP(DS)). Human bone, muscle, and tendon cells obtained from discarded tissue samples during shoulder surgery were placed into culture and treated with the 3 PRP preparations, control media (2% fetal bovine serum [FBS] and 10% FBS), and native blood. Radioactive thymidine assays were obtained to examine cell proliferation, and testing with enzyme-linked immunosorbent assay was used to determine growth factor concentrations. Addition of PRP(LP) to osteocytes, myocytes, and tenocytes significantly increased cell proliferation (P ≤ .05) compared with the controls. Adding PRP(DS) to osteoblasts and tenocytes increased cell proliferation significantly (P ≤ .05), but no significance was shown for its addition to myocytes. The addition of PRP(HP) significantly increased cell proliferation compared with the controls only when added to tenocytes (P ≤ .05). Osteoblasts: Proliferation was significantly increased by addition of PRP(LP) compared with all controls (2% FBS, 10% FBS, native blood) (P ≤ .05). Addition of PRP(DS) led to significantly increased proliferation compared with all controls, native blood, and PRP(HP) (P ≤ .05). Proliferation was significantly less when PRP(HP) was added compared with PRP(DS) (P ≤ .05). Myocytes: Proliferation was significantly increased by addition of PRP(LP) compared with native blood (P ≤ .05). Adding PRP(HP) or PRP(DS) to myocytes showed no significant increase in proliferation compared with the controls or the other separations. Tenocytes: Proliferation was significantly increased by addition of PRP(LP) compared with all controls (2% FBS, 10% FBS, native blood) (P ≤ .05). Addition of PRP(DS) showed a significant increase compared with the controls and native blood. For tenocytes, there was a significant increase (P ≤ .05) seen when PRP(HP) was added compared with the controls and native blood but not compared with the other separations. The primary findings of this study suggest the application of different PRP separations may result in a potential beneficial effect on the clinically relevant target cells in vitro. However, it is unclear which platelet concentration or PRP preparation may be optimal for the treatment of various cell types. In addition, a "more is better" theory for the use of higher platelet concentrations cannot be supported. This study was not intended to prove efficacy but to provide a platform for future research to be built upon. The utilization of different PRP separations may result in a potentially beneficial effect on the clinically relevant target cells in vitro, but it is unclear which platelet concentration or PRP preparation may be optimal for the treatment of various cell types.

  19. Organohalogen concentrations in blood and adipose tissue of Southern Beaufort Sea polar bears.

    PubMed

    Bentzen, T W; Muir, D C G; Amstrup, S C; O'Hara, T M

    2008-11-15

    We analyzed 151 organohalogen chemicals (OHCs) in whole blood and subcutaneous fat of 57 polar bears sampled along the Alaskan Beaufort Sea coast in spring, 2003. All major organochlorine pesticides, PCBs, PBDEs and their congeners were assessed. Concentrations of most OHCs continue to be lower among Southern Beaufort Sea polar bears than reported for other populations. Additionally, toxaphenes and related compounds were assessed in adipose tissue, and 8 perflourinated compounds (PFCs) were examined in blood. Perfluorooctane sulfonate (PFOS) concentrations exceeded those of any other contaminant measured in blood. SigmaChlordane concentrations were higher in females, and both SigmaPCBs and SigmaChlordane concentrations in adipose tissue decreased significantly with age. The rank order of OHC mean concentrations; SigmaPCB>Sigma10PCB>PCB153>SigmaChlordane>Oxychlordane>PCB180>SigmaHCH>beta-HCH>SigmaDDT>p,p-DDE>SigmaPBDE>HCB>Toxaphene was similar for compounds above detection limits in both fat and blood. Although correlation between OHC concentrations in blood and adipose tissue was examined, the predictability of concentrations in one matrix for the other was limited.

  20. Organohalogen concentrations in blood and adipose tissue of Southern Beaufort Sea polar bears

    USGS Publications Warehouse

    Bentzen, T.W.; Muir, D.C.G.; Amstrup, Steven C.; O'Hara, T. M.

    2008-01-01

    We analyzed 151 organohalogen chemicals (OHCs) in whole blood and subcutaneous fat of 57 polar bears sampled along the Alaskan Beaufort Sea coast in spring, 2003. All major organochlorine pesticides, PCBs, PBDEs and their congeners were assessed. Concentrations of most OHCs continue to be lower among Southern Beaufort Sea polar bears than reported for other populations. Additionally, toxaphenes and related compounds were assessed in adipose tissue, and 8 perflourinated compounds (PFCs) were examined in blood. Perfluorooctane sulfonate (PFOS) concentrations exceeded those of any other contaminant measured in blood. ??Chlordane concentrations were higher in females, and both ??PCBs and ??Chlordane concentrations in adipose tissue decreased significantly with age. The rank order of OHC mean concentrations; ??PCB > ??10PCB > PCB153 > ??Chlordane > Oxychlordane > PCB180 > ??HCH > ??-HCH > ??DDT > p,p-DDE > ??PBDE > HCB > Toxaphene was similar for compounds above detection limits in both fat and blood. Although correlation between OHC concentrations in blood and adipose tissue was examined, the predictability of concentrations in one matrix for the other was limited. ?? 2008 Elsevier B.V.

  1. Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction

    NASA Astrophysics Data System (ADS)

    Johnsen, Elin; Leknes, Siri; Wilson, Steven Ray; Lundanes, Elsa

    2015-03-01

    Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.

  2. Screening of Critical Genes and MicroRNAs in Blood Samples of Patients with Ruptured Intracranial Aneurysms by Bioinformatic Analysis of Gene Expression Data.

    PubMed

    Bo, Lijuan; Wei, Bo; Wang, Zhanfeng; Kong, Daliang; Gao, Zheng; Miao, Zhuang

    2017-09-20

    BACKGROUND This study aimed to identify more potential genes and miRNAs associated with the pathogenesis of intracranial aneurysms (IAs). MATERIAL AND METHODS The dataset of GSE36791 (accession number) was downloaded from the Gene Expression Omnibus database. Differentially expressed genes (DEGs) were screened for in the blood samples from patients with ruptured IAs and controls, followed by functional and pathway enrichment analyses. In addition, gene co-expression network was constructed and significant modules were extracted from the network by WGCNA R package. Screening for miRNAs that could regulate DEGs in the modules was performed and an analysis of regulatory relationships was conducted. RESULTS A total of 304 DEGs (167 up-regulated and 137 down-regulated genes) were screened for in blood samples from patients with ruptured IAs compared with those from controls. Functional enrichment analysis showed that the up-regulated genes were mainly associated with immune response and the down-regulated DEGs were mainly concerned with the structure of ribosome and translation. Besides, six functional modules were significantly identified, including four modules enriched by up-regulated genes and two modules enriched by down-regulated genes. Thereinto, the blue, yellow, and turquoise modules of up-regulated genes were all linked with immune response. Additionally, 16 miRNAs were predicted to regulate DEGs in the three modules associated with immune response, such as hsa-miR-1304, hsa-miR-33b, hsa-miR-125b, and hsa-miR-125a-5p. CONCLUSIONS Several genes and miRNAs (such as miR-1304, miR-33b, IRS2 and KCNJ2) may take part in the pathogenesis of IAs.

  3. Assessing immune competence in pigs by immunization with tetanus toxoid.

    PubMed

    Gimsa, U; Tuchscherer, A; Gimsa, J; Tuchscherer, M

    2018-01-01

    Immune competence can be tested by challenging organisms with a set of infectious agents. However, disease control requirements impose restrictions on the infliction of infections upon domestic pigs. Alternatively, vaccinations induce detectable immune responses that reflect immune competence. Here, we tested this approach with tetanus toxoid (TT) in young domestic pigs. To optimize the vaccination protocol, we immunized the pigs with a commercial TT vaccine at the age of 21 or 35 days. Booster immunizations were performed either 14 or 21 days later. TT-specific antibodies in plasma as well as lymphoproliferative responses were determined both 7 and 14 days after booster immunization using ELISA and lymphocyte transformation tests, respectively. In addition, general IgG and IgM plasma concentrations and mitogen-induced proliferation were measured. The highest TT-specific antibody responses were detected when blood samples were collected 1 week after a booster immunization conducted 21 days after primary immunization. The pigs' age at primary immunization did not have a significant influence on TT-specific antibody responses. Similarly, the TT-specific proliferative responses were highest when blood samples were collected 1 week after booster immunization, while age and time of primary and booster immunization were irrelevant in our setup. While general IgG and IgM plasma levels were highly age dependent, there were no significant age effects for TT-specific immune responses. In addition, mitogen-induced proliferation was independent of immunization as well as blood sampling protocols. In summary, our model of TT vaccination provides an interesting approach for the assessment of immune competence in young pigs. The detected vaccination effects were not biased by age, even though our data were acquired from immune systems that were under development during our tests.

  4. NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...

  5. Development of blood-yolk-polymyxin B-trimethoprim agar for the enumeration of Bacillus cereus in various foods.

    PubMed

    Kim, Dong-Hyeon; Kim, Hyunsook; Chon, Jung-Whan; Moon, Jin-San; Song, Kwang-Young; Seo, Kun-Ho

    2013-07-15

    Blood-yolk-polymyxin B-trimethoprim agar (BYPTA) was developed by the addition of egg yolk, laked horse blood, sodium pyruvate, polymyxin B, and trimethoprim, and compared with mannitol-yolk-polymyxin B agar (MYPA) for the isolation and enumeration of Bacillus cereus (B. cereus) in pure culture and various food samples. In pure culture, there was no statistical difference (p>0.05) between the recoverability and sensitivity of MYPA and BYPTA, whereas BYPTA exhibited higher specificity (p<0.05). To evaluate BYPTA agar with food samples, B. cereus was experimentally spiked into six types of foods, triangle kimbab, sandwich, misugaru, Saengsik, red pepper powder, and soybean paste. No statistical difference was observed in recoverability (p>0.05) between MYPA and BYPTA in all tested foods, whereas BYPTA exhibited higher selectivity than MYPA, especially in foods with high background microflora, such as Saengsik, red pepper powder, and soybean paste. The newly developed selective medium BYPTA could be a useful enumeration tool to assess the level of B. cereus in foods, particularly with high background microflora. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. [Analysis of causes and whole microbial structure in a case of rampant caries].

    PubMed

    Hu, Xiao-Yu; Yao, Yu-Fei; Cui, Bo-Miao; Lv, Jun; Shen, Xin; Ren, Biao; Li, Ming-Yun; Guo, Qiang; Huang, Rui-Jie; Li, Yan

    2016-10-20

    To analyze the whole microbial structure in a case of rampant caries to provide evidence for its prevention and treatment. Clinical samples including blood, supragingival plaque, plaque in the caries cavity, saliva, and mucosal swabs were collected with the patient's consent. The blood sample was sent for routine immune test, and the others samples were stained using Gram method and cultured for identifying colonies and 16S rRNA sequencing. DNA was extracted from the samples and tested for the main cariogenic bacterium (Streptococcus mutans) with qPCR, and the whole microbial structure was analyzed using DGGE. The patient had a high levels of IgE and segmented neutrophils in his blood. Streptococci with extremely long chains were found in the saliva samples under microscope. Culture of the samples revealed the highest bacterial concentration in the saliva. The relative content of hemolytic bacterium was detected in the samples, the highest in the caries cavity; C. albicans was the highest in the dental plaque. In addition, 33 bacterial colonies were identified by VITEK system and 16S rDNA sequence phylogenetic analysis, and among them streptococci and Leptotrichia wade were enriched in the dental plaque sample, Streptococcus mutans, Fusobacterium nucleatum, and Streptococcus tigurinus in the caries cavity, and Lactobacillus in the saliva. S. mutans was significantly abundant in the mucosal swabs, saliva and plaque samples of the caries cavity as shown by qPCR. Compared to samples collected from a healthy individual and another two patients with rampant caries, the samples from this case showed a decreased bacterial diversity and increased bacterial abundance shown by PCR-DGGE profiling, and multiple Leptotrichia sp. were detected by gel sequencing. The outgrowth of such pathogenic microorganisms as S. mutans and Leptotrichia sp., and dysbiosis of oral microbial community might contribute to the pathogenesis of rampant caries in this case.

  7. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study

    PubMed Central

    Wahl, Simone; Kunze, Sonja; Molnos, Sophie; Volkova, Nadezda; Schramm, Katharina; Carstensen-Kirberg, Maren; Waldenberger, Melanie; Gieger, Christian; Peters, Annette; Illig, Thomas; Prokisch, Holger; Roden, Michael; Grallert, Harald

    2016-01-01

    Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H) method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10-5 and 0.047). In addition, DNA methylation at cg06500161 (annotated to ABCG1) was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10-5 and 3.0x10-3). Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI) (B-H-adjusted p-values = 0.047). Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1) was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10-9). Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and diabetes-related traits are associated and that these associations are partially BMI-dependent. Furthermore, the interaction of ABCG1 with glucose metabolism is modulated by epigenetic processes. PMID:27019061

  8. Visual detection of copper(II) ions in blood samples by controlling the leaching of protein-capped gold nanoparticles.

    PubMed

    Lee, Yen-Fei; Deng, Ting-Wei; Chiu, Wei-Jane; Wei, Tsao-Yen; Roy, Prathik; Huang, Chih-Ching

    2012-04-21

    We have developed a simple, low-cost, paper-based probe for the selective colorimetric detection of copper ions (Cu(2+)) in aqueous solutions. The bovine serum albumin (BSA)-modified 13.3-nm Au nanoparticle (BSA-Au NP) probe was designed to detect Cu(2+) ions using lead ions (Pb(2+)) and 2-mercaptoethanol (2-ME) as leaching agents in a glycine-NaOH (pH 12.0) solution. In addition, a nitrocellulose membrane (NCM) was used to trap the BSA-Au NPs, leading to the preparation of a nanocomposite film consisting of a BSA-Au NP-decorated membrane (BSA-Au NPs/NCM). The BSA-Au NPs probe operates on the principle that Cu deposition on the surface of the BSA-Au NPs inhibits their leaching ability, which is accelerated by Pb(2+) ions in the presence of 2-ME. Under optimal solution conditions (5 mM glycine-NaOH (pH 12.0), Pb(2+) (50 μM), and 2-ME (1.0 M)), the Pb(2+)/2-ME-BSA-Au NPs/NCM enabled the detection of Cu(2+) at nanomolar concentrations in aqueous solutions by the naked eye with high selectivity (at least 100-fold over other metal ions). In addition, this cost-effective probe allowed for the rapid and simple determination of Cu(2+) ions in not only natural water samples but also in a complex biological sample (in this case, blood sample).

  9. Quantitative, high-resolution epigenetic profiling of CpG loci identifies associations with cord blood plasma homocysteine and birth weight in humans

    PubMed Central

    Ismail, Khaled MK; Haworth, Kim E; Mein, Charles; Carroll, William D

    2011-01-01

    Supplementation with folic acid during pregnancy is known to reduce the risk of neural tube defects and low birth weight. It is thought that folate and other one-carbon intermediates might secure these clinical effects via DNA methylation. We examined the effects of folate on the human methylome using quantitative interrogation of 27,578 CpG loci associated with 14,496 genes at single-nucleotide resolution across 12 fetal cord blood samples. Consistent with previous studies, the majority of CpG dinucleotides located within CpG islands exhibited hypomethylation while those outside CpG islands showed mid-high methylation. However, for the first time in human samples, unbiased analysis of methylation across samples revealed a significant correlation of methylation patterns with plasma homocysteine, LINE-1 methylation and birth weight centile. Additionally, CpG methylation significantly correlated with either birth weight or LINE-1 methylation were predominantly located in CpG islands. These data indicate that levels of folate-associated intermediates in cord blood reflect their influence and consequences for the fetal epigenome and potentially on pregnancy outcome. In these cases, their influence might be exerted during late gestation or reflect those present during the peri-conceptual period. PMID:20864804

  10. Factors influencing European consumer uptake of personalised nutrition. Results of a qualitative analysis.

    PubMed

    Stewart-Knox, Barbara; Kuznesof, Sharron; Robinson, Jenny; Rankin, Audrey; Orr, Karen; Duffy, Maresa; Poínhos, Rui; de Almeida, Maria Daniel Vaz; Macready, Anna; Gallagher, Caroline; Berezowska, Aleksandra; Fischer, Arnout R H; Navas-Carretero, Santiago; Riemer, Martina; Traczyk, Iwona; Gjelstad, Ingrid M F; Mavrogianni, Christina; Frewer, Lynn J

    2013-07-01

    The aim of this research was to explore consumer perceptions of personalised nutrition and to compare these across three different levels of "medicalization": lifestyle assessment (no blood sampling); phenotypic assessment (blood sampling); genomic assessment (blood and buccal sampling). The protocol was developed from two pilot focus groups conducted in the UK. Two focus groups (one comprising only "older" individuals between 30 and 60 years old, the other of adults 18-65 yrs of age) were run in the UK, Spain, the Netherlands, Poland, Portugal, Ireland, Greece and Germany (N=16). The analysis (guided using grounded theory) suggested that personalised nutrition was perceived in terms of benefit to health and fitness and that convenience was an important driver of uptake. Negative attitudes were associated with internet delivery but not with personalised nutrition per se. Barriers to uptake were linked to broader technological issues associated with data protection, trust in regulator and service providers. Services that required a fee were expected to be of better quality and more secure. An efficacious, transparent and trustworthy regulatory framework for personalised nutrition is required to alleviate consumer concern. In addition, developing trust in service providers is important if such services to be successful. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Evidence for negative effects of elevated intra-abdominal pressure on pulmonary mechanics and oxidative stress.

    PubMed

    Davarcı, I; Karcıoğlu, M; Tuzcu, K; İnanoğlu, K; Yetim, T D; Motor, S; Ulutaş, K T; Yüksel, R

    2015-01-01

    To compare the effects of pneumoperitoneum on lung mechanics, end-tidal CO2 (ETCO2), arterial blood gases (ABG), and oxidative stress markers in blood and bronchoalveolar lavage fluid (BALF) during laparoscopic cholecystectomy (LC) by using lung-protective ventilation strategy. Forty-six patients undergoing LC and abdominal wall hernia (AWH) surgery were assigned into 2 groups. Measurements and blood samples were obtained before, during pneumoperitoneum, and at the end of surgery. BALF samples were obtained after anesthesia induction and at the end of surgery. Peak inspiratory pressure, ETCO2, and pCO2 values at the 30th minute were significantly increased, while there was a significant decrease in dynamic lung compliance, pH, and pO2 values in LC group. In BALF samples, total oxidant status (TOS), arylesterase, paraoxonase, and malondialdehyde levels were significantly increased; the glutathione peroxidase levels were significantly decreased in LC group. The serum levels of TOS and paraoxonase were significantly higher at the end of surgery in LC group. In addition, arylesterase level in the 30th minute was increased compared to baseline. Serum paraoxonase level at the end of surgery was significantly increased when compared to AWH group. Our study showed negative effects of pneumoperitoneum in both lung and systemic levels despite lung-protective ventilation strategy.

  12. Impact of electromagnetic radiation emitted by monitors on changes in the cellular membrane structure and protective antioxidant effect of vitamin A - In vitro study.

    PubMed

    Lewicka, Małgorzata; Henrykowska, Gabriela; Zawadzka, Magdalena; Rutkowski, Maciej; Pacholski, Krzysztof; Buczyński, Andrzej

    2017-07-14

    The increasing number of devices emitting electromagnetic radiation (EMR) in people's everyday life attracted the attention of researchers because of possible adverse effects of this factor on living organisms. One of the EMR effect may be peroxidation of lipid membranes formed as a result of free radical process. The article presents the results of in vitro studies aimed at identifying changes in malondialdehyde (MDA) concentration - a marker of lipid peroxidation and antioxidant role of vitamin A during the exposure of blood platelets to electromagnetic radiation generated by liquid-crystal-display (LCD) monitors. Electromagnetic radiation emitted by LCD monitors is characterized by parameters: 1 kHz frequency and 220 V/m intensity (15 cm from display screen). The time of exposure was 30 and 60 min. The study was conducted on porcine blood platelets. The samples were divided into 6 groups: unexposed to radiation, unexposed + vitamin A, exposed for 30 min, exposed for 30 min + vitamin A, exposed for 60 min, exposed for 60 min + vitamin A. The MDA concentration in blood platelets increases significantly as compared to control values after 60 min of exposure to EMR. A significant decrease in MDA concentration after the addition of vitamin A was noticed. In the blood samples exposed to EMR for 30 and 60 min the MDA concentration was significantly increased by addition of vitamin A. The results show the possibly negative effect of electromagnetic radiation on the cellular membrane structure manifested by changes in malondialdehyde concentration and indicate a possible protective role of vitamin A in this process. Int J Occup Med Environ Health 2017;30(5):695-703. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  13. Absence of Association between Cord Specific Antibody Levels and Severe Respiratory Syncytial Virus (RSV) Disease in Early Infants: A Case Control Study from Coastal Kenya.

    PubMed

    Nyiro, Joyce Uchi; Sande, Charles Jumba; Mutunga, Martin; Kiyuka, Patience Kerubo; Munywoki, Patrick Kioo; Scott, John Anthony G; Nokes, David James

    2016-01-01

    The target group for severe respiratory syncytial virus (RSV) disease prevention is infants under 6 months of age. Vaccine boosting of antibody titres in pregnant mothers could protect these young infants from severe respiratory syncytial virus (RSV) associated disease. Quantifying protective levels of RSV-specific maternal antibody at birth would inform vaccine development. A case control study nested in a birth cohort (2002-07) was conducted in Kilifi, Kenya; where 30 hospitalised cases of RSV-associated severe disease were matched to 60 controls. Participants had a cord blood and 2 subsequent 3-monthly blood samples assayed for RSV-specific neutralising antibody by the plaque reduction neutralisation test (PRNT). Two sample paired t test and conditional logistic regression were used in analyses of log2PRNT titres. The mean RSV log2PRNT titre at birth for cases and controls were not significantly different (P = 0.4) and remained so on age-stratification. Cord blood PRNT titres showed considerable overlap between cases and controls. The odds of RSV disease decreased with increase in log2PRNT cord blood titre. There was a 30% reduction in RSV disease per unit increase in log2PRNT titre (<3months age group) but not significant (P = 0.3). From this study, there is no strong evidence of protection by maternal RSV specific antibodies from severe RSV disease. Cord antibody levels show wide variation with considerable overlap between cases and controls. It is likely that, there are additional factors to specific PRNT antibody levels which determine susceptibility to severe RSV disease. In addition, higher levels of neutralizing antibody beyond the normal range may be required for protection; which it is hoped can be achieved by a maternal RSV vaccine.

  14. Ability of anti-glycoprotein IIb/IIIa agents to dissolve platelet thrombi formed on a collagen surface under blood flow conditions.

    PubMed

    Goto, Shinya; Tamura, Noriko; Ishida, Hideyuki

    2004-07-21

    We examined the lytic effects of anti-glycoprotein (GP) IIb/IIIa agents on platelet thrombi formed on the collagen surface under blood flow conditions. Anti-GP IIb/IIIa agents may influence platelet thrombi already formed. Blood samples were anticoagulated either by the specific antithrombin Argatroban (100 microM) or by unfractionated heparin (0.1 U/ml). After platelet thrombi were formed on a collagen surface following 6-min perfusion of whole blood obtained from eight adult donors containing fluorescinated platelets at a wall shear rate of 1,500 s(-1), additional blood samples from the same donors either containing or not containing anti-GP IIb/IIIa agents (abciximab, eptifibatide, or tirofiban) were perfused on these thrombi. The three-dimensional structures of the platelet thrombi were continuously observed by laser confocal microscopy equipped with a piezo-electric motor control unit and recorded. The platelet thrombi started to dissolve after perfusion of blood containing the anti-GP IIb/IIIa agents, whereas their growth resumed after subsequent perfusion of control blood. Only a single layer of platelets having heights of 3 +/- 1 microm, 3 +/- 2 microm, and 3 +/- 1 microm, respectively, could be seen after 6-min perfusion of blood containing abciximab, eptifibatide, and tirofiban, whereas the initial height of the platelet thrombi of 8 +/- 2 microm increased to 11 +/- 4 microm after subsequent perfusion of control blood (n = 8). The volume of the platelet thrombi, which was 3,352 +/- 1,045 microm(3) before starting the second perfusion, was reduced to 778 +/- 102 microm(3), 812 +/- 122 microm(3), and 856 +/- 144 microm(3) after 6-min perfusion of blood containing abciximab, eptifibatide, and tirofiban, respectively. We have shown in this study that anti-GP IIb/IIIa agents possess the ability to dissolve platelet thrombi.

  15. Blood culture contamination in Tanzania, Malawi, and the United States: a microbiological tale of three cities.

    PubMed

    Archibald, Lennox K; Pallangyo, Kisali; Kazembe, Peter; Reller, L Barth

    2006-12-01

    We conducted retrospective, comparative analyses of contamination rates for cultures of blood obtained in the emergency rooms of Muhimbili National Hospital (MNH) in Dar es Salaam, Tanzania; Lilongwe Central Hospital (LCH) in central Malawi; and the Duke University Medical Center (DUMC) in the United States. None of the emergency room patients had indwelling intravascular devices at the time that the blood samples for cultures were obtained. In addition, we reviewed the contamination rates for a cohort of patients already hospitalized in the DUMC inpatient medical service, most of whom had indwelling intravascular devices. The bloodstream infection rates among the patients at MNH (n=513) and LCH (n=486) were similar (approximately 28%); the contamination rates at the two hospitals were 1.3% (7/513) and 0.8% (4/486), respectively. Of 54 microorganisms isolated from cultures of blood collected in the DUMC emergency room, 26 (48%) were identified as skin contaminants. Cultures of blood collected in the DUMC emergency room were significantly more likely to yield growth of contaminants than the cultures of blood collected in the emergency rooms at MNH and LCH combined (26/332 versus 11/1,003; P<0.0001) or collected in the DUMC inpatient medical service (26/332 versus 7/283; P<0.01). For the MNH and LCH blood cultures, lower contamination rates were observed when skin was disinfected with isopropyl alcohol plus tincture of iodine rather than isopropyl alcohol plus povidone-iodine. In conclusion, blood culture contamination was minimized in sub-Saharan African hospitals with substantially limited resources through scrupulous attention to aseptic skin cleansing and improved venipuncture techniques. Application of these principles when blood samples for culture are obtained in U.S. hospital emergency rooms should help mitigate blood culture contamination rates and the unnecessary microbiology workup of skin contaminants.

  16. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  17. Application of Atomic Dielectric Resonance Spectroscopy for the screening of blood samples from patients with clinical variant and sporadic CJD

    PubMed Central

    Fagge, Timothy J; Barclay, G Robin; Stove, G Colin; Stove, Gordon; Robinson, Michael J; Head, Mark W; Ironside, James W; Turner, Marc L

    2007-01-01

    Background Sub-clinical variant Creutzfeldt-Jakob disease (vCJD) infection and reports of vCJD transmission through blood transfusion emphasise the need for blood screening assays to ensure the safety of blood and transplanted tissues. Most assays aim to detect abnormal prion protein (PrPSc), although achieving required sensitivity is a challenge. Methods We have used innovative Atomic Dielectric Resonance Spectroscopy (ADRS), which determines dielectric properties of materials which are established by reflectivity and penetration of radio/micro waves, to analyse blood samples from patients and controls to identify characteristic ADR signatures unique to blood from vCJD and to sCJD patients. Initial sets of blood samples from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) were screened as training samples to determine group-specific ADR characteristics, and provided a basis for classification of blinded sets of samples. Results Blood sample groups from vCJD, sCJD, non-CJD neurological diseases and normal healthy adults (blood donors) screened by ADRS were classified with 100% specificity and sensitivity, discriminating these by a co-variance expert analysis system. Conclusion ADRS appears capable of recognising and discriminating serum samples from vCJD, sCJD, non-CJD neurological diseases, and normal healthy adults, and might be developed to provide a system for primary screening or confirmatory assay complementary to other screening systems. PMID:17760958

  18. The effect of supportive E. coli mastitis treatment on PMN chemiluminescence and subpopulations of T lymphocytes.

    PubMed

    Markiewicz, H; Krumrych, W; Gehrke, M

    2013-01-01

    The aim of this field study was to assess the impact of a single i.m. injection of lysozyme dimer and flunixin meglumine in combination with intramammary and systemic antibiotic on chemiluminescence of PMN (polymorphonuclear leucocytes) and subpopulations of lymphocyte T in blood of cows with E. coli mastitis. Examinations were performed on 30 dairy cows affected with naturally occurring acute form of E. coli mastitis. Cows were randomly divided into three groups according to the method of treatment. The first group was treated with approved intramammary antibiotic product, the same antibiotic in i.m. injection and one injection of flunixin meglumine on the first day of therapy. Next group was treated with the same antibiotic and additionally one injection of lysozyme dimer on the first day of therapy. The third one was treated only with an antibiotic and served as a control group. Blood samples were taken before treatment and on days 3 and 7. In samples haematology indices were determined, spontaneous and opsonised zymosan stimulated CL and PMA measurements were performed and the subpopulations of T lymphocyte (CD2(+), CD4(+), CD8(+)) were assayed in whole blood. There was no effect of the applied supportive treatment on the value of morphological blood indices. A significant influence of the time of sample collection on the level of CL and dynamics of lymphocytes T subpopulation was demonstrated. A single injection of flunixin meglumine or lysozyme dimer on the day of the beginning of treatment of E. coli mastitis, does not affect the level of neutrophil chemiluminescence and the percentage of T lymphocytes in the blood of mastitic cows in the analysed period of time.

  19. Urinary sodium excretion after gastric bypass surgery.

    PubMed

    Docherty, Neil G; Fändriks, Lars; le Roux, Carel W; Hallersund, Peter; Werling, Malin

    2017-09-01

    Gut-kidney signaling is implicated in sodium homeostasis and thus blood pressure regulation. Roux-en-Y gastric bypass (RYGB) surgery for morbid obesity confers a pronounced and long-lasting blood pressure lowering effect in addition to significant weight loss. We set out to establish whether RYGB is associated with an intrinsic change in urinary sodium excretion that may contribute to the reported blood pressure lowering effects of the procedure. University hospital METHODS: Five female patients (age range: 28-50 yr) without metabolic or hypertensive co-morbidities were included in a study involving four 24-hour residential visits: once before surgery and 10 days, 3 months, and 20 months after surgery. Creatinine and sodium were measured in fasting plasma samples and 24-hour urine samples and creatinine clearance, estimated glomerular filtration rate, and indices of urinary sodium excretion were calculated. Fasting and 60-minute postprandial blood samples from each study day were assayed for pro-B-type natriuretic peptide (NT-proBNP). Increases in weight-normalized urinary sodium excretion of up to 2.3-fold in magnitude occurred at 20 months after surgery. Median fractional excretion of sodium at 20 months was double that seen before surgery. Fasting NT-proBNP levels were stable or increased (1.5- to 5-fold). Moreover, a small postprandial increase in NT-proBNP was observed after surgery. Renal fractional excretion of sodium is increased after RYGB. A shift toward increased postoperative basal and meal associated levels of NT-proBNP coincides with increased urinary sodium excretion. The data support a working hypothesis that an enhanced natriuretic gut-kidney signal after RYGB may be of mechanistic importance in the blood pressure lowering effects of this procedure. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  20. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    NASA Astrophysics Data System (ADS)

    Lüdemann, L.; Sreenivasa, G.; Michel, R.; Rosner, C.; Plotkin, M.; Felix, R.; Wust, P.; Amthauer, H.

    2006-06-01

    Assessment of perfusion with 15O-labelled water (H215O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF.

  1. Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system.

    PubMed

    D'Ilio, S; Violante, N; Di Gregorio, M; Senofonte, O; Petrucci, F

    2006-10-10

    A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulization system (APEX-IR) was employed to determine 17 elements (Al, As, Ba, Cd, Co, Cr, Li, Mn, Mo, Ni, Pb, Sb, Se, Sn, Sr, V, and Zr) in blood samples. Ammonia (for Al, Cr, Mn, and V) and O2 (for As and Se) were used as reacting gases. Selection of the best flow rate of the gases and optimization of the quadrupole dynamic bandpass tuning parameter (RPq) were carried out, using digested blood diluted 1+9 with deionized water and spiked with 1 microg L(-1) of Al, Cr, Mn, V and 5 microgL(-1) of As and Se. Detection limits were determined in digested blood using the 3sigma criterion. The desolvating system allowed a sufficient sensitivity to be achieved to determine elements at levels of ng L(-1) without detriment of signal stability. The accuracy of the method was tested with the whole blood certified reference material (CRM), certified for Al, As, Cd, Co, Cr, Mn, Mo, Ni, Pb, Sb, Se, and V, and with indicative values for Ba, Li, Sn, Sr, and Zr. The addition calibration approach was chosen for analysis. In order to confirm the DRC data, samples were also analyzed by means of sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), operating in medium (m/Deltam=4000) and high (m/Deltam=10,000) resolution mode and achieving a good agreement between the two techniques.

  2. Broad-Range PCR Coupled with Electrospray Ionization Time of Flight Mass Spectrometry for Detection of Bacteremia and Fungemia in Patients with Neutropenic Fever

    PubMed Central

    Maertens, J.; Bueselinck, K.; Lagrou, K.

    2016-01-01

    Infection is an important complication in patients with hematologic malignancies or solid tumors undergoing intensive cytotoxic chemotherapy. In only 20 to 30% of the febrile neutropenic episodes, an infectious agent is detected by conventional cultures. In this prospective study, the performance of broad-range PCR coupled with electrospray ionization time of flight mass spectrometry (PCR/ESI-MS) technology was compared to conventional blood cultures (BC) in a consecutive series of samples from high-risk hematology patients. In 74 patients, BC and a whole-blood sample for PCR/ESI-MS (Iridica BAC BSI; Abbott, Carlsbad, CA, USA) were collected at the start of each febrile neutropenic episode and, in case of persistent fever, also at day 5. During 100 different febrile episodes, 105 blood samples were collected and analyzed by PCR/ESI-MS. There was evidence of a bloodstream infection (BSI) in 36/105 cases (34%), based on 14 cases with both PCR/ESI-MS and BC positivity, 17 cases with BC positivity only, and 5 cases with PCR/ESI-MS positivity only. The sensitivity of PCR/ESI-MS was 45%, specificity was 93%, and the negative predictive value was 80% compared to blood culture. PCR/ESI-MS detected definite pathogens (Fusobacterium nucleatum and Streptococcus pneumoniae) missed by BC, whereas it missed both Gram-negative and Gram-positive organisms detected by BC. PCR/ESI-MS testing detected additional microorganisms but showed a low sensitivity (45%) compared to BC in neutropenic patients. Our results indicate a lower concordance between BC and PCR/ESI-MS in the neutropenic population than what has been previously reported in other patient groups with normal white blood cell distribution, and a lower sensitivity than other PCR-based methods. PMID:27440820

  3. Patient identification in blood sampling.

    PubMed

    Davidson, Anne; Bolton-Maggs, Paula

    The majority of adverse reports relating to blood transfusions result from human error, including misidentification of patients and incorrect labelling of samples. This article outlines best practice in blood sampling for transfusion (but is recommended for all pathology samples) and the role of patient empowerment in improving safety.

  4. Hospital-acquired Anemia in Critically Ill Dogs and Cats: A Multi-Institutional Study.

    PubMed

    Lynch, A M; Respess, M; Boll, A E; Bozych, M; McMichael, M; Fletcher, D J; De Laforcade, A M; Rozanski, E A

    2016-01-01

    Hospital-acquired anemia is commonly described in people but limited information currently is available regarding its prevalence in animals. Assess the prevalence of hospital-acquired anemia in hospitalized critically ill dogs and cats, and examine its relationship with phlebotomy practices, transfusion administration, and survival to discharge. Eight hundred and fifty-one client-owned animals (688 dogs and 163 cats). A multicenter, observational study was conducted in which packed cell volume (PCV) was recorded at the time of admission and on subsequent hospitalization days. Signalment, number of blood samples obtained, underlying disease, whether or not blood products were administered, duration of hospitalization, and survival to discharge were recorded. Admission anemia prevalence was 32%, with overall prevalence during the hospitalization period of 56%. The last recorded PCV was significantly lower than the admission PCV for both dogs (admission PCV, 42% [range, 6-67%]; last recorded PCV, 34% [range, 4-64%], P < .0001) and cats (admission PCV, 31% [range, 6-55%]; last recorded PCV, 26% [range, 10-46%], P < .0001). Patients that developed anemia had significantly more blood samples obtained (nonanemic, 5 blood samples [range, 2-54]; anemic, 7 blood samples [range, 2-49], P < .0001). Hospitalized cats were significantly more likely to develop anemia compared to dogs (P < .0001), but anemic dogs were significantly less likely to survive to discharge (P = .0001). Surgical patients were at higher risk of developing hospital-acquired anemia compared to medical patients (OR, 0.63; 95% CI, 0.4-0.9; P = .01). Hospital-acquired anemia occurred frequently, especially in surgical patients. Additional studies focused on the direct effect of phlebotomy practices on the likelihood of anemia development in hospitalized animals are warranted. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Characterization of the disposition of fostamatinib in Japanese subjects including pharmacokinetic assessment in dry blood spots: results from two phase I clinical studies.

    PubMed

    Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael

    2016-01-01

    The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.

  6. Collection and processing of whole blood for transformation of peripheral blood mononuclear cells and extraction of DNA: the Type 1 Diabetes Genetics Consortium

    PubMed Central

    Rosinger, Silke; Nutland, Sarah; Mickelson, Eric; Varney, Michael D; Boehm, Bernard O; Olsem, Gary J; Hansen, John A; Nicholson, Ian; Hilner, Joan E; Perdue, Letitia H; Pierce, June J; Akolkar, Beena; Nierras, Concepcion; Steffes, Michael W

    2010-01-01

    Background and Purpose To yield large amounts of DNA for many genotype analyses and to provide a renewable source of DNA, the Type 1 Diabetes Genetics Consortium (T1DGC) harvested DNA and peripheral blood mononuclear cells (PBMCs) from individuals with type 1 diabetes and their family members in several regions of the world. Methods DNA repositories were established in Asia-Pacific, Europe, North America, and the United Kingdom. To address region-specific needs, different methods and sample processing techniques were used among the laboratories to extract and to quantify DNA and to establish Epstein-Barr virus transformed cell lines. Results More than 98% of the samples of PBMCs were successfully transformed. Approximately 20–25 µg of DNA were extracted per mL of whole blood. Extraction of DNA from the cell pack ranged from 92 to 165 µg per cell pack. In addition, the extracted DNA from whole blood or transformed cells was successfully utilized in each regional human leukocyte antigen genotyping laboratory and by several additional laboratories performing consortium-wide genotyping projects. Limitations Although the isolation of PBMCs was consistent among sites, the measurement of DNA was difficult to harmonize. Conclusions DNA repositories can be established in different regions of the world and produce similar amounts of high-quality DNA for a variety of high-throughput genotyping techniques. Furthermore, even with the distances and time necessary for transportation, highly efficient transformation of PBMCs is possible. For future studies/trials involving several laboratories in different locations, the T1DGC experience includes examples of protocols that may be applicable. In summary, T1DGC has developed protocols that would be of interest to any scientific organization attempting to overcome the logistical problems associated with studies/trials spanning multiple research facilities, located in different regions of the world. PMID:20595244

  7. Molecular and Parasitological Survey of Bovine Piroplasms in the Black Sea Region, Including the First Report of Babesiosis Associated with Babesia divergens in Turkey.

    PubMed

    Aktas, M; Ozubek, S

    2015-11-01

    Clinical cases of babesiosis were evaluated, and the frequency of bovine Babesia and Theileria parasites was determined in cattle. Blood samples and thin blood smears were collected from 23 cattle exhibiting clinical signs of babesiosis. In addition, tick and blood samples were collected from 100 apparently healthy cattle cograzing from the same area. Egg masses obtained from fully engorged female ticks were included. DNA isolated from blood and tick samples was screened for Babesia and Theileria by reverse line blot assay. Piroplasms compatible with Babesia spp. were observed microscopically for symptomatic cattle as circular, oval, elongated, or pear-shaped bodies. Parasitemia ranged from 0.08 to 0.9% for Babesia bovis, 2.5 to 15.4% for Babesia bigemina, and 7.4% for Babesia divergens. Reverse line blot showed positivity in 13 (13%) of the sampled clinically normal cattle and revealed the presence of three Babesia species. Babesia bovis was the most prevalent (9/100, 9%), followed by Babesia occultans (3/100, 3%) and B. bigemina (1/100, 1%). One animal infected with B. bigemina was also infected with B. bovis. The single animal infected with B. divergens showed symptoms of babesiosis. Ticks were identified as Rhipicephalus annulatus, Rhipicephalus turanicus, and Ixodes ricinus. One female R. annulatus and its egg mass were infected with B. bigemina. Neither Theileria annulata nor Theileria buffeli/orientalis infections were observed in cattle or ticks. This is the first report of clinical babesiosis caused by B. divergens in cattle from Turkey. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Comparison of the quantification of acetaminophen in plasma, cerebrospinal fluid and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe

    2013-09-01

    Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Assessment of occupational exposure to welding fumes by inductively coupled plasma-mass spectroscopy and by the alkaline Comet assay.

    PubMed

    Botta, Céline; Iarmarcovai, Gwenaëlle; Chaspoul, Florence; Sari-Minodier, Irène; Pompili, Jocelyne; Orsière, Thierry; Bergé-Lefranc, Jean-Louis; Botta, Alain; Gallice, Philippe; De Méo, Michel

    2006-05-01

    Welding fumes are classified as possibly carcinogenic to humans (Group 2B) by the International Agency for Research on Cancer. In the current study, blood and urine concentrations of aluminum (Al), cadmium (Cd), cobalt (Co), chromium (Cr), manganese (Mn), nickel (Ni), lead (Pb), and zinc (Zn) were monitored by inductively coupled plasma-mass spectrometry (ICP-MS) in 30 welders and in 22 controls. In addition, DNA damage was examined in the lymphocytes of these subjects by the alkaline Comet assay. Two biological samples were taken from the welders at the beginning (BW) and at the end (EW) of a work week. In controls, collection of samples was limited to BW. Blood concentrations of Cd, Co, Cr, Ni, and Pb were higher in the welders than in the control group while higher concentrations of Al, Cd, Co, Cr, Ni, and Pb were detected in welder urines. There was no significant difference in the metal concentrations for the BW and EW welder samples. Increased levels of DNA damage were found in lymphocytes from welders as compared to the controls, and 20/30 welders had higher levels of DNA lesions in the EW than in the BW samples. Age had a significant effect on DNA damage in the control group. Spearman's rank correlation analysis indicated that there were positive correlations between blood concentrations of Al, Co, Ni, and Pb and the levels of DNA damage. A negative correlation was found between DNA damage and Mn in blood, while there was a positive correlation between urinary Mn concentration and DNA damage. These data indicate that occupational exposure to welding fumes increases DNA damage in lymphocytes. Copyright (c) 2006 Wiley-Liss, Inc.

  10. Dissecting Daily and Circadian Expression Rhythms of Clock-Controlled Genes in Human Blood.

    PubMed

    Lech, Karolina; Ackermann, Katrin; Revell, Victoria L; Lao, Oscar; Skene, Debra J; Kayser, Manfred

    2016-02-01

    The identification and investigation of novel clock-controlled genes (CCGs) has been conducted thus far mainly in model organisms such as nocturnal rodents, with limited information in humans. Here, we aimed to characterize daily and circadian expression rhythms of CCGs in human peripheral blood during a sleep/sleep deprivation (S/SD) study and a constant routine (CR) study. Blood expression levels of 9 candidate CCGs (SREBF1, TRIB1, USF1, THRA1, SIRT1, STAT3, CAPRIN1, MKNK2, and ROCK2), were measured across 48 h in 12 participants in the S/SD study and across 33 h in 12 participants in the CR study. Statistically significant rhythms in expression were observed for STAT3, SREBF1, TRIB1, and THRA1 in samples from both the S/SD and the CR studies, indicating that their rhythmicity is driven by the endogenous clock. The MKNK2 gene was significantly rhythmic in the S/SD but not the CR study, which implies its exogenously driven rhythmic expression. In addition, we confirmed the circadian expression of PER1, PER3, and REV-ERBα in the CR study samples, while BMAL1 and HSPA1B were not significantly rhythmic in the CR samples; all 5 genes previously showed significant expression in the S/SD study samples. Overall, our results demonstrate that rhythmic expression patterns of clock and selected clock-controlled genes in human blood cells are in part determined by exogenous factors (sleep and fasting state) and in part by the endogenous circadian timing system. Knowledge of the exogenous and endogenous regulation of gene expression rhythms is needed prior to the selection of potential candidate marker genes for future applications in medical and forensic settings. © 2015 The Author(s).

  11. Molecular detection of Theileria spp. and Babesia spp. in sheep and ixodid ticks from the northeast of Iran.

    PubMed

    Razmi, Gholamreza; Pourhosseini, Moslem; Yaghfouri, Saeed; Rashidi, Ahmad; Seidabadi, Mohsen

    2013-02-01

    Theilerioses and babesioses are important diseases in Iranian sheep. The present study was undertaken to identify and classify/specify Theileria spp. and Babesia spp. in sheep and vector ticks. Investigation was carried out from 2009 to 2011 in the Khorasan Razavi Province, Iran. In total, 302 sheep originating from 60 different flocks were clinically examined and their blood collected. In addition, from the same flocks, ixodid ticks were sampled. Stained blood smears were microscopically examined for the presence of Theileria and Babesia organisms, and a semi-nested PCR was used for subsequent molecular specification. From the ticks, salivary glands and uterus were isolated and subsequently analyzed by semi-nested PCR. Piroplasm organisms were observed in 29% of the blood smears with low parasitemia, whereas 65% of the blood samples yielded positive PCR findings. The presence of Theileria ovis (55.6%), Theileria lestoquardi, and mixed infection with Theileria spp. and Babesia ovis were detected by semi-nested PCR in 0.3%, 5.6%, and 0.99%, respectively. In total, 429 ixodid ticks were collected from different areas of the province. The most prevalent ticks were Rhipicephalus turanicus (n = 376; 87.6% of the total), followed by Hyalomma marginatum turanicum (n = 30; 7.0%), Dermacentor raskemensis (n = 12; 2.8%), Hyalomma anatolicum anatolicum (n = 7; 1.6%), Dermacentor marginatus (n = 2; 0.5%), Rhipicephalus bursa (n = 1; 0.2%), and Haemaphysalis sp. (n = 1; 0.2%). Of the positive R. turanicus samples, 5 (5.7%) were infected with T. ovis and 2 (2.9%) with T. lestoquardi. Neither Babesia ovis nor Babesia motasi infection was detected in salivary glands or uterine samples of the ticks. The results also suggest that R. turanicus could be the vector responsible for transmission of the 2 Theileria species.

  12. Significance of detecting circulating hepatocellular carcinoma cells in peripheral blood of hepatocellular carcinoma patients by nested reverse transcription-polymerase chain reaction and its clinical value: a retrospective study.

    PubMed

    Liu, Yang; Wang, Yue-ru; Wang, Long; Song, Rui-mei; Zhou, Bo; Song, Zhen-shun

    2014-01-01

    Circulating hepatocellular carcinoma cells may be detected by reverse transcription-polymerase chain reaction. We investigated the relationship between circulating hepatocellular carcinoma cells and hepatoma patient survival after different managements and survival periods. Peripheral vein blood (5 ml) samples were obtained from 113 patients with hepatocellular carcinoma and from 33 control subjects (9 with liver cirrhosis after hepatitis B, 14 with chronic hepatitis B, 10 healthy individuals) between January 1, 2009, and December 31, 2013. To detect circulating hepatocellular carcinoma cells in peripheral blood, alpha-fetoprotein messenger RNA was amplified from total RNA extracted from whole blood by reverse transcription-polymerase chain reaction. Alpha-fetoprotein messenger RNA was detected in 59 blood samples from the hepatocellular carcinoma patients (59/113, 52.2%). In contrast, there were no clinical control subjects whose samples showed detectable alpha-fetoprotein messenger RNA. The presence of alpha-fetoprotein messenger RNA in blood seemed to be correlated with the stage (by TNM classification) of hepatocellular carcinoma, serum alpha-fetoprotein value, and the presence of intrahepatic metastasis, portal vein thrombosis, tumor diameter and/or distant metastasis. In addition, alpha-fetoprotein messenger RNA was detected in the blood of 25 patients showing distant metastasis at extrahepatic organs (100%), in contrast to 32 of 88 cases without metastasis (36.4%). All the patients with hepatocellular carcinoma were followed. Seventeen patients with resection of a T 2 stage hepatocellular carcinoma had a survival of 3.2 years after surgical management, 38 cases with resection of a T3 stage hepatocellular carcinoma had a 1.3-year survival, and only 37 cases with T4 stage disease after different treatments except surgery survived for 0.6 years (P <0.01). The presence of alpha-fetoprotein messenger RNA in peripheral blood may be an indicator of circulating hepatocellular carcinoma cells, which might predict hematogenous spreading metastasis in patients with hepatocellular carcinoma and may be a poor prognostic factor for hepatocellular carcinoma patients.

  13. Sampling and storage of blood for pH and blood gas analysis.

    PubMed

    Haskins, S C

    1977-02-15

    Techniques used in sampling and storage of a blood sample for pH and gas measurements can have an important effect on the measured values. Observation of these techniques and principles will minimize in vitro alteration of the pH and blood gas values. To consider that a significant change has occurred in a pH or blood gas measurement from previous values, the change must exceed 0.015 for pH, 3 mm Hg for PCO2, 5 mm Hg for PO2, and 2 mEq/L for [HCO-3] or base excess/deficit. In vitro dilution of the blood sample with anticoagulant should be avoided because it will alter the measured PCO2 and base excess/deficit values. Arterial samples should be collected for meaningful pH and blood gas values. Central venous and free-flowing capillary blood can be used for screening procedures in normal patients but are subject to considerable error. A blood sample can be stored for up to 30 minutes at room temperature without significant change in acid-base values but only up to 12 minutes before significant changes occur in PO2. A blood sample can be stored for up to 3.5 hours in an ice-water bath without significant change in pH and for 6 hours without significant change in PCO2 or PO2. Variations of body temperatures from normal will cause a measurable change in pH and blood gas values when the blood is exposed to the normal water bath temperatures of the analyzer.

  14. Quantification of 18F-fluorocholine kinetics in patients with prostate cancer.

    PubMed

    Verwer, Eline E; Oprea-Lager, Daniela E; van den Eertwegh, Alfons J M; van Moorselaar, Reindert J A; Windhorst, Albert D; Schwarte, Lothar A; Hendrikse, N Harry; Schuit, Robert C; Hoekstra, Otto S; Lammertsma, Adriaan A; Boellaard, Ronald

    2015-03-01

    Choline kinase is upregulated in prostate cancer, resulting in increased (18)F-fluoromethylcholine uptake. This study used pharmacokinetic modeling to validate the use of simplified methods for quantification of (18)F-fluoromethylcholine uptake in a routine clinical setting. Forty-minute dynamic PET/CT scans were acquired after injection of 204 ± 9 MBq of (18)F-fluoromethylcholine, from 8 patients with histologically proven metastasized prostate cancer. Plasma input functions were obtained using continuous arterial blood-sampling as well as using image-derived methods. Manual arterial blood samples were used for calibration and correction for plasma-to-blood ratio and metabolites. Time-activity curves were derived from volumes of interest in all visually detectable lymph node metastases. (18)F-fluoromethylcholine kinetics were studied by nonlinear regression fitting of several single- and 2-tissue plasma input models to the time-activity curves. Model selection was based on the Akaike information criterion and measures of robustness. In addition, the performance of several simplified methods, such as standardized uptake value (SUV), was assessed. Best fits were obtained using an irreversible compartment model with blood volume parameter. Parent fractions were 0.12 ± 0.4 after 20 min, necessitating individual metabolite corrections. Correspondence between venous and arterial parent fractions was low as determined by the intraclass correlation coefficient (0.61). Results for image-derived input functions that were obtained from volumes of interest in blood-pool structures distant from tissues of high (18)F-fluoromethylcholine uptake yielded good correlation to those for the blood-sampling input functions (R(2) = 0.83). SUV showed poor correlation to parameters derived from full quantitative kinetic analysis (R(2) < 0.34). In contrast, lesion activity concentration normalized to the integral of the blood activity concentration over time (SUVAUC) showed good correlation (R(2) = 0.92 for metabolite-corrected plasma; 0.65 for whole-blood activity concentrations). SUV cannot be used to quantify (18)F-fluoromethylcholine uptake. A clinical compromise could be SUVAUC derived from 2 consecutive static PET scans, one centered on a large blood-pool structure during 0-30 min after injection to obtain the blood activity concentrations and the other a whole-body scan at 30 min after injection to obtain lymph node activity concentrations. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Identification of phlebotomine sand fly blood meals by real-time PCR.

    PubMed

    Sales, Kamila Gaudêncio da Silva; Costa, Pietra Lemos; de Morais, Rayana Carla Silva; Otranto, Domenico; Brandão-Filho, Sinval Pinto; Cavalcanti, Milena de Paiva; Dantas-Torres, Filipe

    2015-04-16

    Phlebotomine sand flies are blood-feeding insects of great medical and veterinary significance acting as vectors of Leishmania parasites. Studying the blood-feeding pattern of these insects may help in the understanding of their interactions with potential reservoir hosts of Leishmania parasites. In this study, we developed real time PCR assays for the identification of sand fly blood meal. Six pairs of primers were designed based on cytochrome b gene sequences available in GenBank of the following potential hosts: dog, cat, horse, chicken, black rat, and human. Firstly, SYBR Green-based real time PCR assays were conducted using a standard curve with eight different concentrations (i.e., 10 ng, 1 ng, 100 pg, 10 pg, 1 pg, 100 fg, 10 fg and 1 fg per 2 μl) of DNA samples extracted from EDTA blood samples from each target animal. Then, DNA samples extracted from field-collected engorged female sand flies belonging to three species (i.e., Lutzomyia longipalpis, L. migonei and L. lenti) were tested by the protocols standardized herein. Additionally, female sand flies were experimentally fed on a black rat (Rattus rattus) and used for evaluating the time course of the detection of the protocol targeting this species. The protocols performed well with detection limits of 10 pg to 100 fg. Field-collected female sand flies were fed on blood from humans (73%), chickens (23%), dogs (22%), horses (15%), black rats (11%) and cats (2%). Interestingly, 76.1% of the L. longipalpis females were positive for human blood. In total, 48% of the tested females were fed on single sources, 31% on two and 12% on three. The analysis of the time course showed that the real time PCR protocol targeting the black rat DNA was able to detect small amounts of the host DNA up to 5 days after the blood meal. The real time PCR assays standardized herein successfully detected small amounts of host DNA in female sand flies fed on different vertebrate species and, specifically for the black rats, up to 5 days after the blood meal. These assays represent promising tools for the identification of blood meal in field-collected female sand flies.

  16. Correlation Between Maternal and Fetal Insulin Resistance in Pregnant Women with Gestational Diabetes Mellitus.

    PubMed

    Wang, Xuqin; Yang, Ting; Miao, Jingkun; Liu, Huan; Wu, Kaifeng; Guo, Jing; Chen, Jie; Li, Tingyu

    2018-06-01

    Offspring of mothers with gestational diabetes mellitus (GDM) are far more likely to develop type 2 diabetes. The aim of this study was to investigate the effect of the insulin metabolism of pregnant women with GDM in late pregnancy on the insulin metabolism of the fetuses and their correlation. This study enrolled 55 pregnant women with GDM and 87 control subjects. Fasting venous blood samples and umbilical venous blood samples (reflecting fetal metabolism) were collected from the study subjects. All blood samples were used to evaluate the blood glucose and insulin concentrations. The blood glucose and insulin concentrations were measured using an automatic biochemical analyser and radioimmunoassay, respectively. The homeostasis model assessment (HOMA) was performed to assess the insulin resistance of mother and fetus. 1. The fasting blood glucose, fasting insulin, and HOMA-IR of pregnant women in the late pregnancy GDM group were all significantly higher than those in the control group (fasting blood glucose: 4.70 ± 0.11 vs. 4.11 ± 0.05 mmol/L, p < 0.001; fasting insulin: 44.1 ± 6.76 vs. 25.1 ± 3.58 µU/mL, p = 0.013; HOMA-IR: 8.92 ± 1.25 vs. 5.39 ± 0.83, p = 0.012); 2. The results of logistic regression analyses showed that maternal age, pre-pregnancy body mass index (BMI), and family history of diabetes were high-risk factors for the development of GDM in pregnant women. 3. The insulin level and HOMA-IR in the umbilical venous blood of the late pregnancy GDM group were both significantly higher than those in the control group (insulin: 10.1 ± 1.41 vs. 6.38 ± 0.49 µU/mL, p = 0.035; HOMA-IR: 1.60 ± 0.22 vs. 1.07 ± 0.08, p = 0.006). 4. The umbilical venous blood HOMA-IR in the GDM group positively correlated with the maternal HOMA-IR and fasting insulin level. The neonatal ponderal index (PI) in the GDM group positively correlated with the umbilical venous blood HOMA-IR and insulin level. The HOMA-IR was significantly higher in the late pregnancy GDM women and their fetuses than in the control group. In addition, fetal HOMA-IR positively correlated to maternal HOMA-IR in late pregnancy GDM women.

  17. Label-free cancer cell separation from human whole blood using inertial microfluidics at low shear stress.

    PubMed

    Lee, Myung Gwon; Shin, Joong Ho; Bae, Chae Yun; Choi, Sungyoung; Park, Je-Kyun

    2013-07-02

    We report a contraction-expansion array (CEA) microchannel device that performs label-free high-throughput separation of cancer cells from whole blood at low Reynolds number (Re). The CEA microfluidic device utilizes hydrodynamic field effect for cancer cell separation, two kinds of inertial effects: (1) inertial lift force and (2) Dean flow, which results in label-free size-based separation with high throughput. To avoid cell damages potentially caused by high shear stress in conventional inertial separation techniques, the CEA microfluidic device isolates the cells with low operational Re, maintaining high-throughput separation, using nondiluted whole blood samples (hematocrit ~45%). We characterized inertial particle migration and investigated the migration of blood cells and various cancer cells (MCF-7, SK-BR-3, and HCC70) in the CEA microchannel. The separation of cancer cells from whole blood was demonstrated with a cancer cell recovery rate of 99.1%, a blood cell rejection ratio of 88.9%, and a throughput of 1.1 × 10(8) cells/min. In addition, the blood cell rejection ratio was further improved to 97.3% by a two-step filtration process with two devices connected in series.

  18. Preliminary evidence of attenuated blood pressure reactivity to acute stress in adults following a recent marital separation.

    PubMed

    Grinberg, Austin M; O'Hara, Karey L; Sbarra, David A

    2018-03-01

    This study explores cardiovascular reactivity during an acute-stress task in a sample of recently separated adults. In a cross-sectional design, we examined the association between adults' subjective separation-related distress and changes in heart rate and blood pressure across the acute-stress laboratory paradigm in a sample of 133 (n = 49 men) recently separated adults. Heart rate (HR) and Blood pressure (BP) were recorded across a resting baseline period, a math stressor task, and a recovery period. Multilevel analyses revealed that adults who reported greater separation-related distress exhibited higher initial BP and a slower linear increase in BP across the study period. In addition, adults reporting greater separation-related distress evidenced significantly slower declines in diastolic blood pressure (DBP) following the acute-stress task. HR reactivity was not moderated by separation-related distress. In recently separated adults, preliminary evidence suggests that the context of the stressors may reveal differential patterns of problematic reactivity (exaggerated or blunted responding). Greater emotional intrusion and hyperactivity symptoms may index increased risk for blunted cardiovascular reactivity to general stressors. This pattern of reactivity is consistent with models of allostatic load that emphasise the deleterious effect of hyporesponsivity to environmental demands.

  19. Method of high-precision microsampled blood and plasma mass densitometry

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

  20. A technique for extracting blood samples from mice in fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  1. Cost Analysis of Various Low Pathogenic Avian Influenza Surveillance Systems in the Dutch Egg Layer Sector

    PubMed Central

    Rutten, Niels; Gonzales, José L.; Elbers, Armin R. W.; Velthuis, Annet G. J.

    2012-01-01

    Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. Methodology/Principal Findings The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood), sampling location (farm or packing station) and location of sample preparation (laboratory or packing station). It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393) a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. Conclusions/Significance This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards. PMID:22523543

  2. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...

  3. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia. PMID:26524965

  4. Capillary blood sampling: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Krleza, Jasna Lenicek; Dorotic, Adrijana; Grzunov, Ana; Maradin, Miljenka

    2015-01-01

    Capillary blood sampling is a medical procedure aimed at assisting in patient diagnosis, management and treatment, and is increasingly used worldwide, in part because of the increasing availability of point-of-care testing. It is also frequently used to obtain small blood volumes for laboratory testing because it minimizes pain. The capillary blood sampling procedure can influence the quality of the sample as well as the accuracy of test results, highlighting the need for immediate, widespread standardization. A recent nationwide survey of policies and practices related to capillary blood sampling in medical laboratories in Croatia has shown that capillary sampling procedures are not standardized and that only a small proportion of Croatian laboratories comply with guidelines from the Clinical Laboratory Standards Institute (CLSI) or the World Health Organization (WHO). The aim of this document is to provide recommendations for capillary blood sampling. This document has been produced by the Working Group for Capillary Blood Sampling within the Croatian Society of Medical Biochemistry and Laboratory Medicine. Our recommendations are based on existing available standards and recommendations (WHO Best Practices in Phlebotomy, CLSI GP42-A6 and CLSI C46-A2), which have been modified based on local logistical, cultural, legal and regulatory requirements. We hope that these recommendations will be a useful contribution to the standardization of capillary blood sampling in Croatia.

  5. Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul

    2000-03-01

    Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this technique are a reduction in reagents, higher sensitivity, minimal preparation of complex samples such as blood, real-time calibration, and extremely rapid analysis.

  6. Growth hormone suppression test

    MedlinePlus

    GH suppression test; Glucose loading test; Acromegaly - blood test; Gigantism - blood test ... At least 3 blood samples are taken. The test is done in the following way: The first blood sample is collected between 6 ...

  7. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?

    PubMed

    Rimac, V; Coen Herak, D

    2017-10-01

    Coagulation laboratories are faced on daily basis with requests for additional testing in already analyzed fresh plasma samples. This prompted us to examine whether plasma samples stored at room temperature (RT), and 4°C for 24 hours can be accepted for additional prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen (Fbg), antithrombin (AT), and D-dimer testing. We measured PT, aPTT, Fbg in 50 and AT in 30 plasma samples with normal and pathological values, within 4 hours of blood collection (baseline results) and after 24-hours storage at RT (primary tubes), and 4°C (aliquots). D-dimer stability was investigated in 20 samples stored in primary tubes at 4°C. No statistically significant difference between baseline results and results in samples stored at RT and 4°C was observed for PT (P=.938), aPTT (P=.186), Fbg (P=.962), AT (P=.713), and D-dimers (P=.169). The highest median percentage changes were found for aPTT, being more pronounced for samples stored at 4°C (13.0%) than at RT (8.7%). Plasma samples stored both at RT and 4°C for 24 hours are acceptable for additional PT, Fbg, and AT testing. Plasma samples stored 24 hours in primary tubes at 4°C are suitable for D-dimer testing. © 2017 John Wiley & Sons Ltd.

  8. Age-specific discrimination of blood plasma samples of healthy and ovarian cancer prone mice using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Melikechi, Noureddine; Markushin, Yuri; Connolly, Denise C.; Lasue, Jeremie; Ewusi-Annan, Ebo; Makrogiannis, Sokratis

    2016-09-01

    Epithelial ovarian cancer (EOC) mortality rates are strongly correlated with the stage at which it is diagnosed. Detection of EOC prior to its dissemination from the site of origin is known to significantly improve the patient outcome. However, there are currently no effective methods for early detection of the most common and lethal subtype of EOC. We sought to determine whether laser-induced breakdown spectroscopy (LIBS) and classification techniques such as linear discriminant analysis (LDA) and random forest (RF) could classify and differentiate blood plasma specimens from transgenic mice with ovarian carcinoma and wild type control mice. Herein we report results using this approach to distinguish blood plasma samples obtained from serially bled (at 8, 12, and 16 weeks) tumor-bearing TgMISIIR-TAg transgenic and wild type cancer-free littermate control mice. We have calculated the age-specific accuracy of classification using 18,000 laser-induced breakdown spectra of the blood plasma samples from tumor-bearing mice and wild type controls. When the analysis is performed in the spectral range 250 nm to 680 nm using LDA, these are 76.7 (± 2.6)%, 71.2 (± 1.3)%, and 73.1 (± 1.4)%, for the 8, 12 and 16 weeks. When the RF classifier is used, we obtain values of 78.5 (± 2.3)%, 76.9 (± 2.1)% and 75.4 (± 2.0)% in the spectral range of 250 nm to 680 nm, and 81.0 (± 1.8)%, 80.4 (± 2.1)% and 79.6 (± 3.5)% in 220 nm to 850 nm. In addition, we report, the positive and negative predictive values of the classification of the two classes of blood plasma samples. The approach used in this study is rapid, requires only 5 μL of blood plasma, and is based on the use of unsupervised and widely accepted multivariate analysis algorithms. These findings suggest that LIBS and multivariate analysis may be a novel approach for detecting EOC.

  9. Simultaneous determination of cocaine and opiates in dried blood spots by electrospray ionization tandem mass spectrometry.

    PubMed

    Antelo-Domínguez, Ángel; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2013-12-15

    A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry. © 2013 Elsevier B.V. All rights reserved.

  10. Application of Zeeman graphite furnace atomic absorption spectrometry with high-frequency modulation polarization for the direct determination of aluminum, beryllium, cadmium, chromium, mercury, manganese, nickel, lead, and thallium in human blood.

    PubMed

    Ivanenko, Natalya B; Solovyev, Nikolay D; Ivanenko, Anatoly A; Ganeev, Alexander A

    2012-10-01

    Determination of aluminum (Al), beryllium (Be), cadmium (Cd), chromium (Cr), mercury (Hg), manganese (Mn), nickel (Ni), lead (Pb), and thallium (Tl) concentrations in human blood using high-frequency modulation polarization Zeeman graphite furnace atomic absorption spectrometry (GFAAS) was performed. No sample digestion was used in the current study. Blood samples were diluted with deionized water or 0.1 % (m/v) Triton X-100 solution for Tl. Dilution factors ranged from 1/5 per volume for Be and Tl to 1/20 per volume for Cd and Pb. For Tl, Cd, and Hg, noble metals (gold, platinum, rhodium, etc.) were applied as surface modifiers. To mitigate chloride interference, 2 % (m/v) solution of NH(4)NO(3) was used as matrix modifier for Tl and Ni assessment. The use of Pd(NO(3))(2) as oxidative modifier was necessary for blood Hg and Tl measurement. Validation of the methods was performed by analyzing two-level reference material Seronorm. The precision of the designed methods as relative SD was between 4 and 12 % (middle of a dynamic range) depending on the element. For additional validation, spiked blood samples were analyzed. Limits of detection (LoDs, 3σ, n = 10) for undiluted blood samples were 2.0 μg L(-1) for Al, 0.08 μg L(-1) for Be, 0.10 μg L(-1) for Cd, 2.2 μg L(-1) for Cr, 7 μg L(-1) for Hg, 0.4 μg L(-1) for Mn, 2.3 μg L(-1) for Ni, 3.4 μg L(-1) for Pb, and 0.5 μg L(-1) for Tl. The LoDs achieved allowed determination of Al, Cd, Cr, Mn, Ni, and Pb at both toxic and background levels. Be, Hg, and Tl could be reliably measured at toxic levels only. The methods developed are used for clinical diagnostics and biological monitoring of work-related exposure.

  11. Determination of boron in blood, urine and bone by electrothermal atomic absorption spectrometry using zirconium and citric acid as modifiers

    NASA Astrophysics Data System (ADS)

    Burguera, Marcela; Burguera, José Luis; Rondón, Carlos; Carrero, Pablo

    2001-10-01

    A comparative study of various potential chemical modifiers (Au, Ba, Be, Ca, Cr, Ir, La, Lu, Mg, Ni, Pd, Pt, Rh, Ru, Sr, V, W, and Zr), and different 'coating' treatments (Zr, W, and W+Rh) of the pyrolytic graphite platform of a longitudinally heated graphite tube atomizer for thermal stabilization and determination of boron was undertaken. The use of Au, Ba, Be, Cr, Ir, Pt, Rh, Ru, Sr and V as modifiers, and of W+Rh coating produced erratic, and noisy signals, while the addition of La, Ni and Pd as modifiers, and the W coating had positive effects, but with too high background absorption signals, rendering their use unsuitable for boron determination even in aqueous solutions. The atomic absorption signal for boron was increased and stabilized when the platform was coated with Zr, and by the addition of Ca, Mg, Lu, W or Zr as modifiers. Only the addition of 10 μg of Zr as a modifier onto Zr-treated platforms allowed the use of a higher pyrolysis temperature without analyte losses. The memory effect was minimized by incorporating a cleaning step with 10 μl of 50 g l -1 NH 4F HF after every three boron measurements. The addition of 10 μl of 15 g l -1 citric acid together with Zr onto Zr-treated platforms significantly improved the characteristic mass to m0=282 pg, which is adequate for biological samples such as urine and bone, although the sensitivity was still inadequate for the determination of boron in blood of subjects without supplementary diet. Under optimized conditions, the detection limit (3σ) was 60 μg l -1. The amount of boron found in whole blood, urine and femur head samples from patients with osteoporosis was in agreement with values previously reported in the literature.

  12. [Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].

    PubMed

    Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N

    2011-01-01

    The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form the cubital vein. The counts for RBCs and blood platelets, as well as other qualitative haematological indices (haemoglobin, haematocrit, average volume of the RBC, erythrocytic diameter, etc.) in blood sampled form crural and ulnar veins in the same patient were identical, thus strongly suggesting the lack of either haemodynamic or haemorheological phenomena capable of leading to redistribution of the blood formed elements in varicose veins. Hence a decrease in the counts of leukocytes and their subpopulations in blood sampled from crural varicose veins might be associated with the «leukocytic trap» phenomenon.

  13. [Impact of current approaches to laboratory screening of donated blood and its components on hepatitis B virus infection in patients with blood system diseases].

    PubMed

    Ignatova, E N; Tupoleva, T A; Ovchinnikova, E N; Romanova, T Yu; Yaroslavtseva, N G; Filatov, F P; Troitskaya, V V; Kuzmina, L A; Parovichnikova, E N; Gaponova, T V; Savchenko, V G

    To evaluate the detection rate of markers for hepatitis B virus (HBV) in the blood samples taken from patients with blood system diseases, by applying the current approaches to examining donated blood and its components for markers of viral infections. The investigation included blood samples from patients with blood system diseases (n=364) and donors (n=5,011). The results of laboratory screening of donated blood samples (n=13,081) were retrospectively analyzed. Commercial kits of reagents were used for immunochemical assay and polymerase chain reaction. Patients with blood system diseases were recorded to have markers of active HBV infection in 12.6% of cases, anti-HBc in 31.3%, and anti-HBs in 37.6%. A retrospective analysis of the results of screening donated blood samples showed the presence of markers for active HBV infection in 0.28% of cases. A prospective examination of blood donors revealed markers of HBV infection in 4.83% of cases, including those of active forms in 0.54% and anti-HBc in 4.79%. The markers of active HBV infection in donors were only anti-HBc IgM in 0.42% of cases. The blood samples from donors with an anti-HBs titer of >200 mIU/ml contained anti-HBc IgM in 10.5%. In the last 5-7 years, the detection rate of markers of HBV infection in the blood samples of patients with blood system diseases have remained at a high level. Screening for decreed markers fails to identify people with inapparent infections among the donors. Even high anti-HBs concentrations in the donated blood may be a risk for HBV transmission by transfusion to a recipient.

  14. NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...

  15. NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...

  16. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    NASA Astrophysics Data System (ADS)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.

  17. Human blood RNA stabilization in samples collected and transported for a large biobank

    PubMed Central

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  18. DNA methylation-based measures of biological age: meta-analysis predicting time to death.

    PubMed

    Chen, Brian H; Marioni, Riccardo E; Colicino, Elena; Peters, Marjolein J; Ward-Caviness, Cavin K; Tsai, Pei-Chien; Roetker, Nicholas S; Just, Allan C; Demerath, Ellen W; Guan, Weihua; Bressler, Jan; Fornage, Myriam; Studenski, Stephanie; Vandiver, Amy R; Moore, Ann Zenobia; Tanaka, Toshiko; Kiel, Douglas P; Liang, Liming; Vokonas, Pantel; Schwartz, Joel; Lunetta, Kathryn L; Murabito, Joanne M; Bandinelli, Stefania; Hernandez, Dena G; Melzer, David; Nalls, Michael; Pilling, Luke C; Price, Timothy R; Singleton, Andrew B; Gieger, Christian; Holle, Rolf; Kretschmer, Anja; Kronenberg, Florian; Kunze, Sonja; Linseisen, Jakob; Meisinger, Christine; Rathmann, Wolfgang; Waldenberger, Melanie; Visscher, Peter M; Shah, Sonia; Wray, Naomi R; McRae, Allan F; Franco, Oscar H; Hofman, Albert; Uitterlinden, André G; Absher, Devin; Assimes, Themistocles; Levine, Morgan E; Lu, Ake T; Tsao, Philip S; Hou, Lifang; Manson, JoAnn E; Carty, Cara L; LaCroix, Andrea Z; Reiner, Alexander P; Spector, Tim D; Feinberg, Andrew P; Levy, Daniel; Baccarelli, Andrea; van Meurs, Joyce; Bell, Jordana T; Peters, Annette; Deary, Ian J; Pankow, James S; Ferrucci, Luigi; Horvath, Steve

    2016-09-28

    Estimates of biological age based on DNA methylation patterns, often referred to as "epigenetic age", "DNAm age", have been shown to be robust biomarkers of age in humans. We previously demonstrated that independent of chronological age, epigenetic age assessed in blood predicted all-cause mortality in four human cohorts. Here, we expanded our original observation to 13 different cohorts for a total sample size of 13,089 individuals, including three racial/ethnic groups. In addition, we examined whether incorporating information on blood cell composition into the epigenetic age metrics improves their predictive power for mortality. All considered measures of epigenetic age acceleration were predictive of mortality (p≤8.2x10 -9 ) , independent of chronological age, even after adjusting for additional risk factors (p<5.4x10 -4 ) , and within the racial/ethnic groups that we examined (non-Hispanic whites, Hispanics, African Americans). Epigenetic age estimates that incorporated information on blood cell composition led to the smallest p-values for time to death (p=7.5x10 -43 ). Overall, this study a) strengthens the evidence that epigenetic age predicts all-cause mortality above and beyond chronological age and traditional risk factors, and b) demonstrates that epigenetic age estimates that incorporate information on blood cell counts lead to highly significant associations with all-cause mortality.

  19. Umbilical Arterial Blood Sampling Alters Cerebral Tissue Oxygenation in Very Low Birth Weight Neonates.

    PubMed

    Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F

    2015-11-01

    To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Biochemical Changes in Human Erythrocyte Membranes during Prolonged Cold Storage Under Blood Bank Conditions

    DTIC Science & Technology

    1988-05-01

    per milliliter of protein ( 10 nM lowed by addition of egg lecithin and sodium band 3 dimer). Finally, liposomes con- cholate and extensive dialy is (9...Medicine. Samples pended and washed a second time in the same buffer followed by 3 ofprotein 10-120Mg) were hydrolyzed for 24 hat 110 ’C inconstant

  1. Childhood Exposure to Manganese and Postural Instability in Children living near a Ferromanganese Refinery in Southeastern Ohio

    PubMed Central

    Rugless, Fedoria; Bhattacharya, Amit; Succop, Paul; Dietrich, Kim N.; Cox, Cyndy; Alden, Jody; Kuhnell, Pierce; Barnas, Mary; Wright, Robert; Parsons, Patrick J.; Praamsma, Meredith L.; Palmer, Christopher D.; Beidler, Caroline; Wittberg, Richard; Haynes, Erin N.

    2014-01-01

    Airborne manganese (Mn) exposure can result in neurotoxicity and postural instability in occupationally exposed workers, yet few studies have explored the association ambient exposure to Mn in children and postural stability. The goal of this study was to determine the association between Mn and lead (Pb) exposure, as measured by blood Pb, blood and hair Mn and time weighted distance (TWD) from a ferromanganese refinery, and postural stability in children. A subset of children ages 7–9 years enrolled in the Marietta Community Actively Researching Exposure Study (CARES) were invited to participate. Postural balance was conducted on 55 children residing in Marietta, Ohio and the surrounding area. Samples of blood were collected and analyzed for Mn and Pb, and samples of hair were analyzed for Mn. Neuromotor performance was assessed using postural balance testing with a computer force platform system. Pearson correlations were calculated to identify key covariates. Associations between postural balance testing conditions and Mn and Pb exposure were estimated with linear regression analyses adjusting for gender, age, parent IQ, parent age. Mean blood Mn was 10 μg/L (SEM=0.36), mean blood Pb was 0.85 μg/dL (SEM=0.05), and mean hair Mn was 0.76 μg/g (SEM=0.16). Mean residential distance from the refinery was 11.5 km (SEM=0.46). All three measures of Mn exposure were significantly associated with poor postural balance. In addition, low-level blood Pb was also negatively associated with balance outcomes. We conclude that Mn exposure and low-level blood Pb are significantly associated with poor postural balance. PMID:24370548

  2. African Swine Fever Diagnosis Adapted to Tropical Conditions by the Use of Dried-blood Filter Papers.

    PubMed

    Randriamparany, T; Kouakou, K V; Michaud, V; Fernández-Pinero, J; Gallardo, C; Le Potier, M-F; Rabenarivahiny, R; Couacy-Hymann, E; Raherimandimby, M; Albina, E

    2016-08-01

    The performance of Whatman 3-MM filter papers for the collection, drying, shipment and long-term storage of blood at ambient temperature, and for the detection of African swine fever virus and antibodies was assessed. Conventional and real-time PCR, viral isolation and antibody detection by ELISA were performed on paired samples (blood/tissue versus dried-blood 3-MM filter papers) collected from experimentally infected pigs and from farm pigs in Madagascar and Côte d'Ivoire. 3-MM filter papers were used directly in the conventional and real-time PCR without previous extraction of nucleic acids. Tests that performed better with 3-MM filter papers were in descending order: virus isolation, real-time UPL PCR and conventional PCR. The analytical sensitivity of real-time UPL PCR on filter papers was similar to conventional testing (virus isolation or conventional PCR) on organs or blood. In addition, blood-dried filter papers were tested in ELISA for antibody detection and the observed sensitivity was very close to conventional detection on serum samples and gave comparable results. Filter papers were stored up to 9 months at 20-25°C and for 2 months at 37°C without significant loss of sensitivity for virus genome detection. All tests on 3-MM filter papers had 100% specificity compared to the gold standards. Whatman 3-MM filter papers have the advantage of being cheap and of preserving virus viability for future virus isolation and characterization. In this study, Whatman 3-MM filter papers proved to be a suitable support for the collection, storage and use of blood in remote areas of tropical countries without the need for a cold chain and thus provide new possibilities for antibody testing and virus isolation. © 2014 Blackwell Verlag GmbH.

  3. On-Chip Titration of an Anticoagulant Argatroban and Determination of the Clotting Time within Whole Blood or Plasma Using a Plug-Based Microfluidic System

    PubMed Central

    Song, Helen; Li, Hung-Wing; Munson, Matthew S.; Van Ha, Thuong G.; Ismagilov, Rustem F.

    2006-01-01

    This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0–1.5 μg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 °C) and physiological temperature (37 °C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor’s blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 °C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other. PMID:16841902

  4. Loss of chromosome Y in blood, but not in brain, of suicide completers.

    PubMed

    Kimura, Atsushi; Hishimoto, Akitoyo; Otsuka, Ikuo; Okazaki, Satoshi; Boku, Shuken; Horai, Tadasu; Izumi, Takeshi; Takahashi, Motonori; Ueno, Yasuhiro; Shirakawa, Osamu; Sora, Ichiro

    2018-01-01

    Men have a higher rate of completed suicide than women, which suggests that sex chromosome abnormalities may be related to the pathophysiology of suicide. Recent studies have found an aberrant loss of chromosome Y (LOY) in various diseases; however, no study has investigated whether there is an association between LOY and suicide. The purpose of this study was to determine whether LOY occurs in men who completed suicide. Our study consisted of 286 male Japanese subjects comprised of 140 suicide completers without severe physical illness (130 post-mortem samples of peripheral blood and 10 brains) and 146 age-matched control subjects (130 peripheral blood samples from healthy individuals and 16 post-mortem brains). LOY was measured as the chromosome Y/chromosome X ratio of the fluorescent signal of co-amplified short sequences from the Y-X homologous amelogenin genes (AMELY and AMELX). Regression analyses showed that LOY in the blood of suicide completers was significantly more frequent than that found in controls (odds ratio = 3.50, 95% confidence interval = 1.21-10.10), but not in the dorsolateral prefrontal cortex (DLPFC) region of brain. Normal age-dependent LOY in blood was found in healthy controls (r = -0.353, p < 0.001), which was not seen in suicide completers (r = -0.119, p = 0.177). DLPFC tissue had age-dependent LOY (B = -0.002, p = 0.015), which was independent of phenotype. To our knowledge, this is the first study demonstrating that LOY in blood is associated with suicide completion. In addition, our findings are the first to also indicate that age-dependent LOY may occur not only in blood, but also in specific brain regions.

  5. Event-free survival of infants and toddlers enrolled in the HR-NBL-1/SIOPEN trial is associated with the level of neuroblastoma mRNAs at diagnosis.

    PubMed

    Corrias, Maria V; Parodi, Stefano; Tchirkov, Andrei; Lammens, Tim; Vicha, Ales; Pasqualini, Claudia; Träger, Catarina; Yáñez, Yania; Dallorso, Sandro; Varesio, Luigi; Luksch, Roberto; Laureys, Genevieve; Valteau-Couanet, Dominique; Canete, Adela; Pöetschger, Ulrike; Ladenstein, Ruth; Burchill, Susan A

    2018-07-01

    The purpose of this study was to evaluate whether levels of neuroblastoma mRNAs in bone marrow and peripheral blood from stage M infants (≤12 months of age at diagnosis, MYCN amplified) and toddlers (between 12 and 18 months, any MYCN status) predict event-free survival (EFS). Bone marrow aspirates and peripheral blood samples from 97 infants/toddlers enrolled in the European High-Risk Neuroblastoma trial were collected at diagnosis in PAXgene ™ blood RNA tubes. Samples were analyzed by reverse transcription quantitative polymerase chain reaction according to standardized procedures. Bone marrow tyrosine hydroxylase (TH) or paired-like homeobox 2b (PHOX2B) levels in the highest tertile were associated with worse EFS; hazard ratios, adjusted for age and MYCN status, were 1.5 and 1.8 respectively. Expression of both TH and PHOX2B in the highest tertile predicted worse outcome (p = 0.015), and identified 20 (23%) infants/toddlers with 5-year EFS of 20% (95%CI: 4%-44%). Prognostic significance was maintained after adjusting for over-fitting bias (p = 0.038), age and MYCN status. In peripheral blood, PHOX2B levels in the highest tertile predicted a two-fold increased risk of an event (p = 0.032), and identified 23 (34%) infants/toddlers with 5-year EFS of 29% (95%CI: 12%-48%). Time-dependent receiver operating characteristic analysis confirmed the prognostic value of combined TH and PHOX2B in bone marrow and of PHOX2B in peripheral blood during the first year of follow-up. High levels of bone marrow TH and PHOX2B and of peripheral blood PHOX2B at diagnosis allow early identification of a group of high-risk infant and toddlers with neuroblastoma who may be candidates for alternative treatments. Integration with additional biomarkers, as well as validation in additional international trials is warranted. © 2018 Wiley Periodicals, Inc.

  6. [Contribution of nested PCR in the diagnosis of imported malaria in southern Algeria].

    PubMed

    Bouiba, L; Gassen, B; Gasmi, M; Hammadi, D; Harrat, Z

    2016-12-01

    The nested PCR was used to estimate its inputs in malaria diagnosis and in the performance of the microscope operators involved in the surveillance of malaria in remote areas of South Algeria. For the period 2010 to 2015, 112 patients (93 febrile and 19 asymptomatic) coming from sub-Saharan Africa were tested for malaria in the hospital of Tamanrasset. One part of the blood taken from fingertip was used for blood smears and the second part was absorbed in filter paper for molecular diagnosis. Overall, the infection was detected by nested PCR in 63 samples versus 53 by direct examination. In addition, 11 mixed infections and 6 positive asymptomatic cases not detected by microscopy were diagnosed by PCR. Moreover, two negative samples in nested PCR were tested positive by direct examination. The molecular tool is more sensitive than the direct examination in detecting infra-microscopic parasitaemia and mixed infections...

  7. Torque teno virus infection in male commercial sex workers in Surakarta Indonesia

    NASA Astrophysics Data System (ADS)

    Prasetyo, Afiono Agung; Luvi, Sabrina Damara; Hartono, Sari, Yulia

    2017-02-01

    The molecular epidemiology data of torque teno virus (TTV) in Indonesia is very rare. This study evaluated the prevalence of TTV in male commercial sex workers, as one of the high risk community for blood borne viruses pathogens in Surakarta, Indonesia. All blood samples collected from male commercial sex workers in Surakarta in 2009-2013 were tested by nested polymerase chain reaction (PCR). The amplified PCR products were molecularly cloned and subjected to sequence analysis. TTV DNA was detected in 80.9% (72/89) samples. Furthermore, the molecular characterization revealed that the most prevalent was genogroup 3, followed by genogroup 2 and l, respectively. TTV was detected in male commercial sex workers in Surakarta with high infection rate. Further investigation about TTV circulation in Indonesian population is needed in order to provide additional information about the genetic variability and TTV epidemiology in Indonesia, especially in the high risk communities.

  8. A "live" biopsy in a small-cell lung cancer patient by detection of circulating tumor cells.

    PubMed

    Bevilacqua, Simona; Gallo, Marianna; Franco, Renato; Rossi, Antonio; De Luca, Antonella; Rocco, Gaetano; Botti, Gerardo; Gridelli, Cesare; Normanno, Nicola

    2009-07-01

    A 71-year-old patient with a pulmonary lesion was diagnosed with a low-grade neuroendocrine tumor following examination of a fine needle aspiration biopsy. Analysis of a peripheral blood sample with the CellSearch system revealed the presence of putative circulating tumor cells (CTC) that were positive for EpCAM and cytokeratin (CK) expression. Since EpCAM is not usually expressed in neuroendocrine tumors, we performed a biopsy of liver metastases. Morphological and immunophenotypical characterization revealed that the patient had an EpCAM and CK positive small-cell lung cancer (SCLC). By using the CellSearch apparatus, EpCAM/CK positive CTC were detected in peripheral blood samples from 3 out of 4 additional SCLC patients. This study is the first to demonstrate that CTC can be identified in SCLC patients by using the CellSearch system.

  9. Isolation of human genomic DNA for genetic analysis from premature neonates: a comparison between newborn dried blood spots, whole blood and umbilical cord tissue

    PubMed Central

    2013-01-01

    Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095

  10. Rapid Diagnosis of Bloodstream Infections with PCR Followed by Mass Spectrometry

    PubMed Central

    Jordana-Lluch, Elena; Carolan, Heather E.; Giménez, Montserrat; Sampath, Rangarajan; Ecker, David J.; Quesada, M. Dolores; Mòdol, Josep M.; Arméstar, Fernando; Blyn, Lawrence B.; Cummins, Lendell L.; Ausina, Vicente; Martró, Elisa

    2013-01-01

    Achieving a rapid microbiological diagnosis is crucial for decreasing morbidity and mortality of patients with a bloodstream infection, as it leads to the administration of an appropriate empiric antimicrobial therapy. Molecular methods may offer a rapid alternative to conventional microbiological diagnosis involving blood culture. In this study, the performance of a new technology that uses broad-spectrum PCR coupled with mass spectrometry (PCR/ESI-MS) was evaluated for the detection of microorganisms directly from whole blood. A total of 247 whole blood samples and paired blood cultures were prospectively obtained from 175 patients with a suspicion of sepsis. Both sample types were analyzed using the PCR/ESI-MS technology, and the results were compared with those obtained by conventional identification methods. The overall agreement between conventional methods and PCR/ESI-MS performed in blood culture aliquots was 94.2% with 96.8% sensitivity and 98.5% specificity for the molecular method. When comparing conventional methods with PCR/ESI-MS performed in whole blood specimens, the overall agreement was 77.1% with 50% sensitivity and 93.8% specificity for the molecular method. Interestingly, the PCR/ESI-MS technology led to the additional identification of 13 pathogens that were not found by conventional methods. Using the PCR/ESI-MS technology the microbiological diagnosis of bloodstream infections could be anticipated in about half of the patients in our setting, including a small but significant proportion of patients newly diagnosed. Thus, this promising technology could be very useful for the rapid diagnosis of sepsis in combination with traditional methods. PMID:23626775

  11. Evaluation of Nucleic Acid Stabilization Products for Ambient Temperature Shipping and Storage of Viral RNA and Antibody in a Dried Whole Blood Format

    PubMed Central

    Dauner, Allison L.; Gilliland, Theron C.; Mitra, Indrani; Pal, Subhamoy; Morrison, Amy C.; Hontz, Robert D.; Wu, Shuenn-Jue L.

    2015-01-01

    Loss of sample integrity during specimen transport can lead to false-negative diagnostic results. In an effort to improve upon the status quo, we used dengue as a model RNA virus to evaluate the stabilization of RNA and antibodies in three commercially available sample stabilization products: Whatman FTA Micro Cards (GE Healthcare Life Sciences, Pittsburgh, PA), DNAstāble Blood tubes (Biomātrica, San Diego, CA), and ViveST tubes (ViveBio, Alpharetta, GA). Both contrived and clinical dengue-positive specimens were stored on these products at ambient temperature or 37°C for up to 1 month. Antibody and viral RNA levels were measured by enzyme-linked immunosorbent assay (ELISA) and quantitative reverse transcription polymerase chain reaction (qRT-PCR) assays, respectively, and compared with frozen unloaded controls. We observed reduced RNA and antibody levels between stabilized contrived samples and frozen controls at our earliest time point, and this was particularly pronounced for the FTA cards. However, despite some time and temperature dependent loss, a 94.6–97.3% agreement was observed between stabilized clinical specimens and their frozen controls for all products. Additional considerations such as cost, sample volume, matrix, and ease of use should inform any decision to incorporate sample stabilization products into a diagnostic testing workflow. We conclude that DNAstāble Blood and ViveST tubes are useful alternatives to traditional filter paper for ambient temperature shipment of clinical specimens for downstream molecular and serological testing. PMID:25940193

  12. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    PubMed Central

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640

  13. Season, molt, and body size influence mercury concentrations in grebes

    USGS Publications Warehouse

    Hartman, Christopher; Ackerman, Joshua T.; Herzog, Mark; Eagles-Smith, Collin A.

    2017-01-01

    We studied seasonal and physiological influences on mercury concentrations in western grebes (Aechmophorus occidentalis) and Clark's grebes (A. occidentalis) across 29 lakes and reservoirs in California, USA. Additionally, at three of these lakes, we conducted a time series study, in which we repeatedly sampled grebe blood mercury concentrations during the spring, summer, and early fall. Grebe blood mercury concentrations were higher among males (0.61 ± 0.12 μg/g ww) than females (0.52 ± 0.10 μg/g ww), higher among Clark's grebes (0.58 ± 0.12 μg/g ww) than western grebes (0.51 ± 0.10 μg/g ww), and exhibited a strong seasonal pattern (decreasing by 60% from spring to fall). Grebe blood THg concentrations exhibited a shallow, inverse U-shaped pattern with body size, and was lowest among the smallest and largest grebes. Further, the relationship between grebe blood mercury concentrations and wing primary feather molt exhibited a shallow U-shaped pattern, where mercury concentrations were highest among birds that had not yet begun molting, decreased approximately 24% between pre-molt and late molt, and increased approximately 19% from late molt to post-molt. Because grebes did not begin molting until mid-summer, lower grebe blood mercury concentrations observed in late summer and early fall were consistent with the onset of primary feather molt. However, because sampling date was a much stronger predictor of grebe mercury concentrations than molt, other seasonally changing environmental factors likely played a larger role than molt in the seasonal variation in grebe mercury concentrations. In the time series study, we found that seasonal trends in grebe mercury concentrations were not consistent among lakes, indicating that lake-specific variation in mercury dynamics influence the overall seasonal decline in grebe blood mercury concentrations. These results highlight the importance of accounting for sampling date, as well as ecological processes that may influence mercury concentrations, when developing monitoring programs to assess site-specific exposure risk of mercury to wildlife.

  14. Fundamental study on non-invasive blood glucose sensing.

    PubMed

    Xu, K; Li, Q; Lu, Z; Jiang, J

    2002-01-01

    Diabetes is a disease which severely threatens the health of human beings. Unfortunately, current monitoring techniques with finger sticks discourage the regular use. Noninvasive spectroscopic measurement of blood glucose is a simple and painless technique, and reduces the long-term health care costs of diabetic patients due to no reagents. It is suitable for home use. Moreover, the establishment of the methodology not only applies to blood glucose noninvasive measurement, but also can be extended to noninvasive measurement of other analytes in body fluid, which will be of important significance for the development of the technique of clinical analysis. In this paper, some fundamental researches, which have been achieved in our laboratory in the field of non-invasive blood glucose measurement, were introduced. 1. Fundamental research was done for the glucose concentrations from simple to complex samples with near and middle infrared spectroscopy: (1) the relationship between the instrument precision and prediction accuracy of the glucose measurement; (2) the change of the result of the quantitative measurement with the change of the complexity of samples; (3) the attempt of increasing the prediction accuracy of the glucose measurement by improving the methods of modeling. The research results showed that it is feasible for non-invasive blood glucose measurement with near and middle infrared spectroscopy in theory, and the experimental results, from simple to complex samples, proved that it is effective for the methodology consisting of hardware and software. 2. According to the characteristics of human body measurement, the effects of measuring conditions on measurement results, such as: (1) the effect of measurement position; (2) the effect of measurement pressure; (3) the effect of measurement site; (4) the effect of measured individual, were investigated. With the fundamental researches, the special problems of human body measurement were solved. In addition, the practical and effective method of noninvasive human blood glucose measurement was proposed.

  15. Fatal outcome of coinfection of Crimean-Congo hemorrhagic fever and malaria.

    PubMed

    Christova, Iva; Petrov, Andrei; Papa, Anna; Vutchev, Dimitar; Kalvatchev, Nikolay; Vatev, Nikolay; Stoycheva, Mariana

    2015-01-01

    Here, we report a case of a Bulgarian patient with imported falciparum malaria that manifested 6 days after his arrival in Bulgaria, which was complicated by bloody diarrhea 2 days later. Blood smear revealed high parasitemia, with annular forms and gametocytes of Plasmodium falciparum. In addition, RNA of the Crimean-Congo hemorrhagic fever (CCHF) virus was detected in the blood sample by real-time reverse transcription (RT)-PCR and nested RT-PCR. The obtained sequence was found to be clustered within the Europe 1 lineage close to the other Bulgarian strains. Notably, the two infectious diseases may appear with many similar symptoms that are difficult to distinguish.

  16. Table salt and blood pressure in Greek children.

    PubMed

    Adamopoulos, P N; Chaniotis, F; Kodoyianis, S; Boutsicakis, J; Madalos, P; Kassos, D; Gatos, A; Moulopoulos, S

    1987-12-01

    The habit of adding table salt was studied in a random sample of 2209 children 6-18 years old. Of these 10% routinely added table salt to prepared food before tasting it (group A), 29% after tasting it (group B) and 61% ate their food as it was prepared, without additional use of table salt (group C). Group A had higher blood pressure (BP), prevalence of systolic BP greater than or equal to 130 mmHG and body mass index (BMI) than groups B and C (P less than 0.0001). These differences were also observed in group B versus C (P less than 0.0001).

  17. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    NASA Technical Reports Server (NTRS)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  18. Antibody levels correlate with detection of Trypanosoma cruzi DNA by sensitive PCR assays in seropositive blood donors and possible resolution of infection over time

    PubMed Central

    Sabino, E.C.; Lee, T.H.; Montalvo, L.; Nguyen, M.L.; Leiby, D.A.; Carrick, D.M.; Otani, M.M.; Vinelli, E.; Wright, D.; Stramer, S.L.; Busch, M.

    2013-01-01

    Background The clinical significance of anti-T. cruzi low-level reactive samples is incompletely understood. PCR-positive rates and antibody levels among seropositive blood donors in three countries are described. Methods Follow-up whole blood and plasma samples were collected from T. cruzi-seropositive donors from 2008-2010 in the US (n=195) and Honduras (n=58). Also 143 samples from Brazil in 1996-2002, originally positive by three serological assays, were available and paired with contemporary follow-up samples from these donors. All samples were retested with the FDA-approved Ortho ELISA. PCR assays were performed on coded sample panels by two laboratories (BSRI and ARC) that amplified kinetoplast minicircle DNA sequences of T. cruzi. Results PCR testing at BSRI yielded slightly higher overall sensitivity and specificity (33% and 98%) compared with the ARC lab (28% and 94%). Among seropositive donors, PCR-positive rates varied by country (p<0.0001) for the BSRI laboratory: Brazil (57%), Honduras (32%) and the US (14%). ELISA signal/cutoff (S/CO) ratios were significantly higher for PCR-positive compared to PCR-negative donors (p<0.05 for all comparisons). Additionally, PCR-negative Brazilian donors exhibited greater frequencies of antibody decline over time versus PCR-positive donors (p=0.003). Conclusion For all three countries, persistent DNA positivity correlated with higher ELISA S/CO values, suggesting that high-level seroreactivity reflects chronic parasitemia. The higher rate of PCR positivity for Brazilian donors was likely attributable to required reactivity on three assays available a decade ago. Significant S/CO declines in 10% of the PCR-negative Brazilian donors may indicate seroreversion following parasite clearance in the absence of treatment. PMID:23002996

  19. Genomic DNA Methylation Changes in Response to Folic Acid Supplementation in a Population-Based Intervention Study among Women of Reproductive Age

    PubMed Central

    Berry, Robert J.; Hao, Ling; Li, Zhu; Maneval, David; Yang, Thomas P.; Rasmussen, Sonja A.; Yang, Quanhe; Zhu, Jiang-Hui; Hu, Dale J.; Bailey, Lynn B.

    2011-01-01

    Folate is a source of one-carbons necessary for DNA methylation, a critical epigenetic modification necessary for genomic structure and function. The use of supplemental folic acid is widespread however; the potential influence on DNA methylation is unclear. We measured global DNA methylation using DNA extracted from samples from a population-based, double-blind randomized trial of folic acid supplementation (100, 400, 4000 µg per day) taken for 6 months; including a 3 month post-supplementation sample. We observed no changes in global DNA methylation in response to up to 4,000 µg/day for 6 months supplementation in DNA extracted from uncoagulated blood (approximates circulating blood). However, when DNA methylation was determined in coagulated samples from the same individuals at the same time, significant time, dose, and MTHFR genotype-dependent changes were observed. The baseline level of DNA methylation was the same for uncoagulated and coagulated samples; marked differences between sample types were observed only after intervention. In DNA from coagulated blood, DNA methylation decreased (−14%; P<0.001) after 1 month of supplementation and 3 months after supplement withdrawal, methylation decreased an additional 23% (P<0.001) with significant variation among individuals (max+17%; min-94%). Decreases in methylation of ≥25% (vs. <25%) after discontinuation of supplementation were strongly associated with genotype: MTHFR CC vs. TT (adjusted odds ratio [aOR] 12.9, 95%CI 6.4, 26.0). The unexpected difference in DNA methylation between DNA extracted from coagulated and uncoagulated samples in response to folic acid supplementation is an important finding for evaluating use of folic acid and investigating the potential effects of folic acid supplementation on coagulation. PMID:22163281

  20. Seroprevalence of Helicobacter pylori in school-aged Chinese in Taipei City and relationship between ABO blood groups.

    PubMed

    Wu, Tzee-Chung; Chen, Liang-Kung; Hwang, Shinn-Jang

    2003-08-01

    To explore the seropositive rate of antibodies against H. pylori (anti-HP) in Taipei City and to compare the relationship of ABO blood groups and H. pylori infection. In 1993, high school students in Shih-Lin District were randomly selected for blood samplings by their registration number at school. In addition, similar procedures were performed on the well-children clinics of Taipei Veterans General Hospital. Besides, randomly selected sera from the adults who took the physical examination were recruited for evaluation. Informed consents were obtained from all the subjects before blood samplings and parents were simultaneously informed for those who were younger than 18-year-old. Blood tests for anti-HP and ABO blood groupings were performed by enzyme-linked immunosorbent assay. Chi square tests were used for the comparisons between seroprevalence of H. pylori and ABO blood groups. Totally, 685 subjects were recruited (260 children aged 1-14 years, 425 high school students aged 15-18 years) were evaluated, and another 88 adult healthy volunteers were studied as well for comparison. The age-specific seropositive rate of anti-HP was 1.3 % at age 1-5 years, 7.7 % at age 6-10 years, and 11.5 % at age 11-14 years. The seroprevalence of H. pylori infection was abruptly increased in young adolescence: 18.6 % at age 15 years, 28.1 % at age 16 years, 32.4 % at age 17 years and 41.0 % at age 18 years, respectively. In the 425 high school students, ABO blood groupings were performed, which disclosed 48.5 % (206/425) of blood group O, 24 % (102/425) of blood group A, 21.8 % (93/425) of blood group B and 5.6 % (24/425) of blood group AB. In comparison of the subjects with blood group O and the other blood groups, no statistical significance could be identified in the seroprevalence of H. pylori (P=0.99). The seroprevalence of H. pylori infection in Taipei City in adults is similar to the developed countries, and the abrupt increase of H. pylori during high school may be resulted from marked increase of interpersonal social activities. Although blood group O was reported to be related to H. pylori infection in previous literature, we found no association between H. pylori infection and ABO blood groups.

  1. Seroprevalence of Helicobacter pylori in school-aged Chinese in Taipei City and relationship between ABO blood groups

    PubMed Central

    Wu, Tzee-Chung; Chen, Liang-Kung; Hwang, Shinn-Jang

    2003-01-01

    AIM: To explore the seropositive rate of antibodies against H. pylori (anti-HP) in Taipei City and to compare the relationship of ABO blood groups and H. pylori infection. METHODS: In 1993, high school students in Shih-Lin District were randomly selected for blood samplings by their registration number at school. In addition, similar procedures were performed on the well-children clinics of Taipei Veterans General Hospital. Besides, randomly selected sera from the adults who took the physical examination were recruited for evaluation. Informed consents were obtained from all the subjects before blood samplings and parents were simultaneously informed for those who were younger than 18-year-old. Blood tests for anti-HP and ABO blood groupings were performed by enzyme-linked immunosorbent assay. Chi square tests were used for the comparisons between seroprevalence of H. pylori and ABO blood groups. RESULTS: Totally, 685 subjects were recruited (260 children aged 1-14 years, 425 high school students aged 15-18 years) were evaluated, and another 88 adult healthy volunteers were studied as well for comparison. The age-specific seropositive rate of anti-HP was 1.3% at age 1-5 years, 7.7% at age 6-10 years, and 11.5% at age 11-14 years. The seroprevalence of H. pylori infection was abruptly increased in young adolescence: 18.6% at age 15 years, 28.1% at age 16 years, 32.4% at age 17 years and 41.0% at age 18 years, respectively. In the 425 high school students, ABO blood groupings were performed, which disclosed 48.5% (206/425) of blood group O, 24% (102/425) of blood group A, 21.8% (93/425) of blood group B and 5.6% (24/425) of blood group AB. In comparison of the subjects with blood group O and the other blood groups, no statistical significance could be identified in the seroprevalence of H. pylori (P = 0.99). CONCLUSION: The seroprevalence of H. pylori infection in Taipei City in adults is similar to the developed countries, and the abrupt increase of H. pylori during high school may be resulted from marked increase of interpersonal social activities. Although blood group O was reported to be related to H. pylori infection in previous literature, we found no association between H. pylori infection and ABO blood groups. PMID:12918114

  2. Automated extraction of DNA from blood and PCR setup using a Tecan Freedom EVO liquid handler for forensic genetic STR typing of reference samples.

    PubMed

    Stangegaard, Michael; Frøslev, Tobias G; Frank-Hansen, Rune; Hansen, Anders J; Morling, Niels

    2011-04-01

    We have implemented and validated automated protocols for DNA extraction and PCR setup using a Tecan Freedom EVO liquid handler mounted with the Te-MagS magnetic separation device (Tecan, Männedorf, Switzerland). The protocols were validated for accredited forensic genetic work according to ISO 17025 using the Qiagen MagAttract DNA Mini M48 kit (Qiagen GmbH, Hilden, Germany) from fresh whole blood and blood from deceased individuals. The workflow was simplified by returning the DNA extracts to the original tubes minimizing the risk of misplacing samples. The tubes that originally contained the samples were washed with MilliQ water before the return of the DNA extracts. The PCR was setup in 96-well microtiter plates. The methods were validated for the kits: AmpFℓSTR Identifiler, SGM Plus and Yfiler (Applied Biosystems, Foster City, CA), GenePrint FFFL and PowerPlex Y (Promega, Madison, WI). The automated protocols allowed for extraction and addition of PCR master mix of 96 samples within 3.5h. In conclusion, we demonstrated that (1) DNA extraction with magnetic beads and (2) PCR setup for accredited, forensic genetic short tandem repeat typing can be implemented on a simple automated liquid handler leading to the reduction of manual work, and increased quality and throughput. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  3. Infectivity of pre-seroconversion donations: an analysis of lookback exercises in The Netherlands, 2000-2006.

    PubMed

    Lieshout-Krikke, R W; van 't Ende, E A; Slot, E; Karomi, S; Kivit, R M H; Zaaijer, H L

    2012-04-01

    Blood can be infectious if it is donated shortly before infection with hepatitis B virus (HBV), hepatitis C virus (HCV) or human immunodeficiency virus (HIV) becomes detectable. Lookback exercises may detect infection in recipients of pre-seroconversion donations. This study provides an analysis of the Dutch lookback exercises in the years 2000 through 2006. All lookback procedures, triggered by 50 repeat donors seroconverting for HBV (n=32), HCV (n=3), HIV (n=14) and HBV + HIV (n=1), were analysed. Recipients and archived samples of the 96 implicated donations were tested. For 76 donations, a stored sample was available for HBV, HCV, or HIV PCR testing, revealing two HBV-DNA-positive pre-seroconversion donations. Ninety-three lookback procedures were initiated, to which 91 of 93 hospitals responded. In 87 of 91 cases, the implicated blood product had been administered. In 39 of 87 cases, the recipient was tested, revealing one HIV and two HBV infections. The HIV infection was considered pre-existent. The two HBV-positive patients received components from the donation of which the repository sample tested positive for HBV-DNA. Components of the second HBV-positive pre-seroconversion donation had not been administered. Among 39 recipients of pre-seroconversion donations, 2 (5%) were found HBV infected by transfusion. The labour-intensive lookback procedures did not reveal any conclusive transmissions additional to the infections detected by PCR testing of repository pre-seroconversion samples. © 2011 The Author(s). Vox Sanguinis © 2011 International Society of Blood Transfusion.

  4. Hepatitis E virus RNA in Australian blood donations.

    PubMed

    Shrestha, Ashish C; Flower, Robert L P; Seed, Clive R; Keller, Anthony J; Harley, Robert; Chan, Hiu-Tat; Hoad, Veronica; Warrilow, David; Northill, Judith; Holmberg, Jerry A; Faddy, Helen M

    2016-12-01

    Hepatitis E virus (HEV) poses a risk to transfusion safety. In Australia, locally acquired HEV is rare and cases are mainly reported in travelers returning from countries endemic for HEV. The risk posed by HEV to transfusion safety in Australia is unknown; therefore, we aimed to measure the rate of current HEV infection in Australian blood donations. A total of 14,799 blood donations were tested for HEV RNA by transcription-mediated amplification, with confirmatory testing by reverse transcription-polymerase chain reaction. Viral load quantification and phylogenetic analysis was performed on HEV RNA-positive samples. One (0.0068%; 95% confidence interval [CI], 0.0002%-0.0376%) sample was confirmed positive for HEV RNA, resulting in a risk of collecting a HEV-viremic donation of 1 in 14,799 (95% CI, 1 in 584,530 to 1 in 2,657). The viral load in this sample was approximately 15,000 IU/mL, and it was determined to be Genotype 3. Our finding of 1 in 14,799 Australian donations positive for HEV RNA is lower than that from many other developed countries; this is consistent with the relatively low seroprevalence in Australia. As this HEV RNA-positive sample was Genotype 3, it seems likely that this infection was acquired through zoonotic transmission, either within Australia or overseas in a developed nation. HEV has the potential to pose a risk to transfusion safety in Australia; however, additional, larger studies are required to quantify the magnitude of this risk. © 2016 AABB.

  5. Advantages of analyzing postmortem brain samples in routine forensic drug screening-Case series of three non-natural deaths tested positive for lysergic acid diethylamide (LSD).

    PubMed

    Mardal, Marie; Johansen, Sys Stybe; Thomsen, Ragnar; Linnet, Kristian

    2017-09-01

    Three case reports are presented, including autopsy findings and toxicological screening results, which were tested positive for the potent hallucinogenic drug lysergic acid diethylamide (LSD). LSD and its main metabolites were quantified in brain tissue and femoral blood, and furthermore hematoma and urine when available. LSD, its main metabolite 2-oxo-3-hydroxy-LSD (oxo-HO-LSD), and iso-LSD were quantified in biological samples according to a previously published procedure involving liquid-liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). LSD was measured in the brain tissue of all presented cases at a concentration level from 0.34-10.8μg/kg. The concentration level in the target organ was higher than in peripheral blood. Additional psychoactive compounds were quantified in blood and brain tissue, though all below toxic concentration levels. The cause of death in case 1 was collision-induced brain injury, while it was drowning in case 2 and 3 and thus not drug intoxication. However, the toxicological findings could help explain the decedent's inability to cope with brain injury or drowning incidents. The presented findings could help establish reference concentrations in brain samples and assist in interpretation of results from forensic drug screening in brain tissue. This is to the author's knowledge the first report of LSD, iso-LSD, and oxo-HO-LSD measured in brain tissue samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Determination of paraldehyde by gas chromatography in whole blood from children.

    PubMed

    Githiga, Isaiah M; Muchohi, Simon N; Ogutu, Bernhards R; Newton, Charles R J C; Otieno, Godfrey O; Gitau, Evelyn N; Kokwaro, Gilbert O

    2004-06-15

    A rapid, sensitive and selective gas chromatographic method with flame ionization detection was developed for the determination of paraldehyde in small blood samples taken from children. Whole blood samples (300 microl) collected in a 3 ml Wheaton glass sample vial were spiked with acetone (internal standard: 15 ng) followed by addition of concentrated hydrochloric acid. The mixture was heated in the sealed airtight sample vial in a water bath (96 Celsius; 5 min) to depolymerize paraldehyde to acetaldehyde. A 2 ml aliquot of the headspace was analyzed by gas chromatography with flame ionization detector using a stainless steel column (3 m x 4 mm i.d.) packed with 10% Carbowax 20 M/ 2% KOH on 80/100 Chromosorb WAW. Calibration curves were linear from 1.0-20 microg (r2>0.99). The limit of detection was 1.5 microg/ml, while relative mean recoveries at 2 and 18 microg were 105.6 +/- 8.4 and 101.2 +/- 5.9%, respectively (n = 10 for each level). Intra- and inter-assay relative standard deviations at 2, 10 and 18 microg were <15%. There was no interference from other drugs concurrently used in children with severe malaria, such as anticonvulsants (diazepam, phenytoin, phenobarbitone), antipyretics/analgesics (paracetamol and salicylate), antibiotics (gentamicin, chloramphenicol, benzyl penicillin) and antimalarials (chloroquine, quinine, proguanil, cycloguanil, pyrimethamine and sulfadoxine). The method was successfully applied for pharmacokinetic studies of paraldehyde in children with convulsions associated with severe malaria.

  7. Maternal blood, plasma, and breast milk lead: lactational transfer and contribution to infant exposure.

    PubMed

    Ettinger, Adrienne S; Roy, Ananya; Amarasiriwardena, Chitra J; Smith, Donald; Lupoli, Nicola; Mercado-García, Adriana; Lamadrid-Figueroa, Hector; Tellez-Rojo, Martha Maria; Hu, Howard; Hernández-Avila, Mauricio

    2014-01-01

    Human milk is a potential source of lead exposure. Yet lactational transfer of lead from maternal blood into breast milk and its contribution to infant lead burden remains poorly understood. We explored the dose-response relationships between maternal blood, plasma, and breast milk to better understand lactational transfer of lead from blood and plasma into milk and, ultimately, to the breastfeeding infant. We measured lead in 81 maternal blood, plasma, and breast milk samples at 1 month postpartum and in 60 infant blood samples at 3 months of age. Milk-to-plasma (M/P) lead ratios were calculated. Multivariate linear, piecewise, and generalized additive models were used to examine dose-response relationships between blood, plasma, and milk lead levels. Maternal lead levels (mean±SD) were as follows: blood: 7.7±4.0 μg/dL; plasma: 0.1±0.1 μg/L; milk: 0.8±0.7 μg/L. The average M/P lead ratio was 7.7 (range, 0.6-39.8) with 97% of the ratios being >1. The dose-response relationship between plasma lead and M/P ratio was nonlinear (empirical distribution function=6.5, p=0.0006) with the M/P ratio decreasing by 16.6 and 0.6 per 0.1 μg/L of plasma lead, respectively, below and above 0.1 μg/L plasma lead. Infant blood lead level (3.4±2.2 μg/dL) increased by 1.8 μg/dL per 1 μg/L milk lead (p<0.0001, R2=0.3). The M/P ratio for lead in humans is substantially higher than previously reported, and transfer of lead from plasma to milk may be higher at lower levels of plasma lead. Breast milk is an important determinant of lead burden among breastfeeding infants.

  8. Serological and molecular investigation of Ehrlichia spp. and Anaplasma spp. in ticks and blood of dogs, in the Thrace Region of Turkey.

    PubMed

    Çetinkaya, Handan; Matur, Erdal; Akyazi, İbrahim; Ekiz, Elif Ergul; Aydin, Levent; Toparlak, Mufit

    2016-07-01

    In recent years, tick-borne diseases like ehrlichiosis and anaplasmosis became widespread worldwide threatening the health of both human and companion animals. Therefore, the aim of this study was to determine the presence of Anaplasma spp., and Ehrlichia spp. in dogs and ticks in the Thrace Region of Turkey. A total of 400 blood samples and 912 ticks were collected from dogs living in shelters that are located in four cities (Istanbul, Edirne, Tekirdag and Kirklareli) of the Thrace Region. Blood and buffy coat smears were prepared for microscopic examination. Hematologic and serologic analyses were performed using cell counter and commercial Snap3Dx test kit, respectively. Eight hundred fifty of collected ticks were classified as Rhipicephalus sanguineus, 33 as Rhipicephalus turanicus and 29 as Ixodes ricinus. After DNA extraction from blood samples and pooled ticks (127 tick pools, in total), nested PCR was performed to detect the DNA of Anaplasma spp., and Ehrlichia spp. The seroprevalence of Ehrlichia canis was 27.25% (109) by Snap3Dx test and the total molecular positivity was 11.75% (47) in dog blood samples and 21.25% (27) in tick pools by nested PCR. The frequencies of the infected blood samples with E. canis, Anaplasma phagocytophilum and Anaplasma platys were detected as 6%, 4% and 6%, respectively. E. canis and A. platys were detected in R. sanguineus pools with a ratio of 15.75% and 0.7%, respectively. In addition, A. platys was also detected in R. turanicus pools (0.7%). A. phagocytophilum was found only in I. ricinus pools (3.93%). Morulae of three species were detected in buffy coat and blood smears. While anemia was observed in dogs infected with E. canis and co-infected (with one or more species), thrombocytopenia was observed only in co-infected dogs. This is the first study providing evidence for the presence of Anaplasma spp. and Ehrlichia spp. in dogs and ticks in the Thrace Region of Turkey. Based on the results of the tests used in this study, we recommend the combined use of serologic, molecular, cytologic, hematologic analyses and physical examination of tick exposure for an accurate diagnosis of ehrlichiosis and anaplasmosis. Copyright © 2016 Elsevier GmbH. All rights reserved.

  9. A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.

    PubMed

    Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita

    2016-12-01

    Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements.

    PubMed

    Porter, Charlotte A; Bradley, Kevin M; McGowan, Daniel R

    2018-05-01

    The aim of this study was to verify, with a large dataset of 1394 Cr-EDTA glomerular filtration rate (GFR) studies, the equivalence of slope-intercept and single-sample GFR. Raw data from 1394 patient studies were used to calculate four-sample slope-intercept GFR in addition to four individual single-sample GFR values (blood samples taken at 90, 150, 210 and 270 min after injection). The percentage differences between the four-sample slope-intercept and each of the single-sample GFR values were calculated, to identify the optimum single-sample time point. Having identified the optimum time point, the percentage difference between the slope-intercept and optimal single-sample GFR was calculated across a range of GFR values to investigate whether there was a GFR value below which the two methodologies cannot be considered equivalent. It was found that the lowest percentage difference between slope-intercept and single-sample GFR was for the third blood sample, taken at 210 min after injection. The median percentage difference was 2.5% and only 6.9% of patient studies had a percentage difference greater than 10%. Above a GFR value of 30 ml/min/1.73 m, the median percentage difference between the slope-intercept and optimal single-sample GFR values was below 10%, and so it was concluded that, above this value, the two techniques are sufficiently equivalent. This study supports the recommendation of performing single-sample GFR measurements for GFRs greater than 30 ml/min/1.73 m.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...

  12. Modification of beta-cell response to different postprandial blood glucose concentrations by prandial repaglinide and combined acarbose/repaglinide application.

    PubMed

    Rosak, C; Hofmann, U; Paulwitz, O

    2004-06-01

    This study was designed to compare the effects of repaglinide plus acarbose combination treatment to repaglinide alone on postprandial glucose, serum insulin, C-peptide and proinsulin concentrations. A total of 40 patients with Type 2 diabetes (T2DM) (fasting blood glucose: 120-180 mg/dl; postprandial blood glucose: 140-240 mg/dl) were included in this single-centre, controlled, randomised, single-dose, cross-over study. On two consecutive days, patients either received 2 mg repaglinide 15 min before breakfast followed by 100 mg acarbose with breakfast or repaglinide alone. Two fasting (7.30 h, 8.00 h) and five postprandial blood samples (from 8.30 h to 12.00 h) were taken for blood glucose, serum insulin, C-peptide and proinsulin determination. Repaglinide plus acarbose treatment significantly reduced the mean increase in postprandial blood glucose levels (24.2+/-18.2 mg/dl) compared to repaglinide alone (51.1+/-29.0 mg/dl; p<0.001). Serum insulin, C-peptide and proinsulin levels [mean area under the curve (AUC7.30-12.00h)] were significantly lower than those observed with repaglinide monotherapy (e.g. insulin: 1089.2+/-604.5 hr x pmol/l and 1596.8+/-1080.6 hr x pmol/l, resp., p<0.001), suggesting that acarbose modifies the rapid insulin release induced by repaglinide. Prandial treatment with a combination of acarbose and repaglinide results in an additive glucose lowering effect and modified insulin secretion compared to repaglinide alone. Postprandial hyperglycaemia is not abolished by rapid stimulation of insulin release induced by repaglinide. Additional reduction of postprandial blood glucose by acarbose modifies the stimulation of insulin release.

  13. Community as client: reaching an underserved urban community and meeting unmet primary health care needs.

    PubMed

    Aponte, Judith; Nickitas, Donna M

    2007-01-01

    In a collaborative effort to address the health disparities within 1 urban underserved community, the Hunter-Bellevue School of Nursing, Hunter College, and the Mount Sinai Medical Center organized a health fair. Nursing faculty worked side by side with undergraduate nursing students to offer several health promotion activities, screening, and educational sessions for residents of East Harlem, New York. In addition, nursing students provided individual patient education on nutrition, hand washing hygiene, medication review, and glucometer usage. Educational materials on lifestyle issues (sample meals, maintaining normal blood glucose, blood pressure, cholesterol levels, and smoking cessation) were provided. To help bridge the gap between health education and health promotion activities, nursing students, many of whom were bilingual, served as translators for non-English speaking Spanish and Chinese residents. In addition to the new professional partnerships developed, new clinical placements for nursing students were established.

  14. The use of immunochromatographic rapid test for soft tissue remains identification in order to distinguish between human and non-human origin.

    PubMed

    Gascho, Dominic; Morf, Nadja V; Thali, Michael J; Schaerli, Sarah

    2017-05-01

    Clear identification of soft tissue remains as being of non-human origin may be visually difficult in some cases e.g. due to decomposition. Thus, an additional examination is required. The use of an immunochromatographic rapid tests (IRT) device can be an easy solution with the additional advantage to be used directly at the site of discovery. The use of these test devices for detecting human blood at crime scenes is a common method. However, the IRT is specific not only for blood but also for differentiation between human and non-human soft tissue remains. In the following this method is discussed and validated by means of two forensic cases and several samples of various animals. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  15. [Identification of Animal Whole Blood Based on Near Infrared Transmission Spectroscopy].

    PubMed

    Wan, Xiong; Wang, Jian; Liu, Peng-xi; Zhang, Ting-ting

    2016-01-01

    The inspection and classification for blood products are important but complicated in import-export ports or inspection and quarantine departments. For the inspection of whole blood products, open sampling can cause pollution and virulence factors in bloods samples may even endanger inspectors. Thus non-contact classification and identification methods for whole bloods of animals are needed. Spectroscopic techniques adopted in the flowcytometry need sampling blood cells during the detection; therefore they can not meet the demand of non-contact identification and classification for whole bloods of animals. Infrared absorption spectroscopy is a technique that can be used to analyze the molecular structure and chemical bonds of detected samples under the condition of non-contact. To find a feasible spectroscopic approach of non-contact detection for the species variation in whole blood samples, a near infrared transmitted spectra (NITS, 4 497.669 - 7 506.4 cm(-1)) experiment of whole blood samples of three common animals including chickens, dogs and cats has been conducted. During the experiment, the spectroscopic resolution is 5 cm(-1), and each spectrogram is an average of 5 measured spectral data. Experimental results show that all samples have a sharp absorption peak between 5 184 and 5 215 cm(-1), and a gentle absorption peak near 7 000 cm(-1). Besides, the NITS curves of different samples of same animals are similar, and only have slight differences in the whole transmittance. A correlation coefficient (CC) is induced to distinguish the differences of the three animals' whole bloods in NITS curves, and the computed CCs between NITS curves of different samples of the same animals, are greater than 0.99, whereas CCs between NITS curves of the whole bloods of different animals are from 0.509 48 to 0.916 13. Among which CCs between NITS curves of the whole bloods of chickens and cats are from 0.857 23 to 0.912 44, CCs between NITS curves of the whole bloods of chickens and dogs are from 0.509 48 to 0.664 82, and CCs between NITS curves of the whole bloods of cats and dogs are from 0.872 75 to 0.916 13. The cat and the dog belong to the class of mammal, and the CCs between their whole bloods NITS curves are greater than those between chickens and cats, or chickens and dogs, which are hetero-class animals. Namely, the whole bloods NITS curves of the cat and the dog have higher similarity. These results of NITS provide a feasible method of non-contact identification of animal whole bloods.

  16. The role of the medical laboratory technologist in drinking and driving cases. Part 1: The Criminal Code and blood collection for alcohol analysis.

    PubMed

    Westenbrink, W

    1992-01-01

    Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.

  17. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  18. NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...

  19. NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...

  20. Hepatitis B core antigen antibody as an indicator of a low grade carrier state for hepatitis B virus in a Saudi Arabian blood donor population.

    PubMed

    Bernvil, S S; Andrews, V; Kuhns, M C; McNamara, A L

    1997-03-01

    Blood donor screening for anti-hepatitis B core antigen (anti-HBc) was introduced as a surrogate marker of non-A, non-B hepatitis prior to the availability of a specific test for hepatitis C. In areas endemic for hepatitis B virus (HBV), such as Saudi Arabia, earlier studies indicated that up to 30% of blood donors might disqualify if screened for anti-HBc. The issue was readdressed in a study of 6035 consecutive first-time Saudi national blood donors in an attempt to identify a subgroup of anti-HBc positive donors who might be at high risk of being low grade carriers of HBV. An isolated anti-HBc of high titer in a donor with a low or absent anti-hepatitis B surface antigen (anti-HBsAg) was taken as an indicator of increased risk of a low grade carrier state. Using this algorithm, an additional 125 (2%) donors would disqualify. HBsAg immune complex assays and polymerase chain reaction of donor samples with an isolated anti-HBc identified two donors with immune complexes and two donors with HBV DNA. All four donor samples expressed over 90% neutralization in the anti-HBc supplementary testing, indicating high titer anti-HBc. These findings seem to support the suggested policy of donor exclusion based on the anti-HBc and anti-HBsAg serology as a means to eliminate low grade carriers of HBV in endemic areas without jeopardizing the blood supply.

  1. Effect of boron addition on injection molded 316L stainless steel: mechanical, corrosion properties and in vitro bioactivity.

    PubMed

    Bayraktaroglu, Esra; Gulsoy, H Ozkan; Gulsoy, Nagihan; Er, Ozay; Kilic, Hasan

    2012-01-01

    The research was investigated the effect of boron additions on sintering characteristics, mechanical, corrosion properties and biocompatibility of injection molded austenitic grade 316L stainless steel. Addition of boron is promoted to get high density of sintered 316L stainless steels. The amount of boron plays a role in determining the sintered microstructure and all properties. In this study, 316L stainless steel powders have been used with the elemental NiB powders. A feedstock containing 62.5 wt% powders loading was molded at different injection molded temperature. The binders were completely removed from molded components by solvent and thermal debinding at different temperature. The debinded samples were sintered at different temperature for 60 min. Mechanical property, microstructural characterization and electrochemical property of the sintered samples were performed using tensile testing, hardness, optical, scanning electron microscopy and electrochemical corrosion experiments. Sintered samples were immersed in a simulated body fluid (SBF) with elemental concentrations that were comparable to those of human blood plasma for a total period of 15 days. Both materials were implanted in fibroblast culture for biocompatibility evaluations were carried out. Results of study showed that sintered 316L and 316L with NiB addition samples exhibited high mechanical and corrosion properties in a physiological environment. Especially, 316L with NiB addition can be used in some bioapplications.

  2. Effects of sample handling methods on substance P concentrations and immunoreactivity in bovine blood samples.

    PubMed

    Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong

    2014-02-01

    To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.

  3. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  4. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    PubMed

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  5. Automation of DNA and miRNA co-extraction for miRNA-based identification of human body fluids and tissues.

    PubMed

    Kulstein, Galina; Marienfeld, Ralf; Miltner, Erich; Wiegand, Peter

    2016-10-01

    In the last years, microRNA (miRNA) analysis came into focus in the field of forensic genetics. Yet, no standardized and recommendable protocols for co-isolation of miRNA and DNA from forensic relevant samples have been developed so far. Hence, this study evaluated the performance of an automated Maxwell® 16 System-based strategy (Promega) for co-extraction of DNA and miRNA from forensically relevant (blood and saliva) samples compared to (semi-)manual extraction methods. Three procedures were compared on the basis of recovered quantity of DNA and miRNA (as determined by real-time PCR and Bioanalyzer), miRNA profiling (shown by Cq values and extraction efficiency), STR profiles, duration, contamination risk and handling. All in all, the results highlight that the automated co-extraction procedure yielded the highest miRNA and DNA amounts from saliva and blood samples compared to both (semi-)manual protocols. Also, for aged and genuine samples of forensically relevant traces the miRNA and DNA yields were sufficient for subsequent downstream analysis. Furthermore, the strategy allows miRNA extraction only in cases where it is relevant to obtain additional information about the sample type. Besides, this system enables flexible sample throughput and labor-saving sample processing with reduced risk of cross-contamination. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. The influence of bone and blood lead on plasma lead levels in environmentally exposed adults.

    PubMed Central

    Hernández-Avila, M; Smith, D; Meneses, F; Sanin, L H; Hu, H

    1998-01-01

    There is concern that previously accumulated bone lead stores may constitute an internal source of exposure, particularly during periods of increased bone mineral loss (e.g., pregnancy, lactation, and menopause). Furthermore, the contribution of lead mobilized from bone to plasma may not be adequately reflected by whole-blood lead levels. This possibility is especially alarming because plasma is the main circulatory compartment of lead that is available to cross cell membranes and deposit in soft tissues. We studied 26 residents of Mexico City who had no history of occupational lead exposure. Two samples of venous blood were collected from each individual. One sample was analyzed by inductively coupled plasma-magnetic sector mass spectrometry for whole-blood lead levels. The other sample was centrifuged to separate plasma, which was then isolated and analyzed for lead content by the same analytical technique. Bone lead levels in the tibia and patella were determined with a spot-source 109Cd K-X-ray fluorescence instrument. Mean lead concentrations were 0.54 microg/l in plasma, 119 microg/l in whole blood, and 23.27 and 11.71 microg/g bone mineral in the patella and tibia, respectively. The plasma-to-whole-blood lead concentration ratios ranged from 0.27% to 0.70%. Whole-blood lead level was highly correlated with plasma lead level and accounted for 95% of the variability of plasma lead concentrations. Patella and tibia lead levels were also highly correlated with plasma lead levels. The bivariate regression coefficients of patella and tibia on plasma lead were 0.034 (p<0. 001) and 0.053 (p<0.001), respectively. In a multivariate regression model of plasma lead levels that included whole-blood lead, patella lead level remained an independent predictor of plasma lead level (ss = 0.007, p<0.001). Our data suggest that although whole-blood lead levels are highly correlated with plasma lead levels, lead levels in bone (particularly trabecular bone) exert an additional independent influence on plasma lead levels. It will be important to determine whether the degree of this influence increases during times of heightened bone turnover (e.g., pregnancy and lactation). Images Figure 1 Figure 2 PMID:9681974

  7. Compression and flexural strength of bone cement mixed with blood.

    PubMed

    Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W

    2016-08-01

    To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.

  8. Integrated Blood Barcode Chips

    PubMed Central

    Fan, Rong; Vermesh, Ophir; Srivastava, Alok; Yen, Brian K.H.; Qin, Lidong; Ahmad, Habib; Kwong, Gabriel A.; Liu, Chao-Chao; Gould, Juliane; Hood, Leroy; Heath, James R.

    2008-01-01

    Blood comprises the largest version of the human proteome1. Changes of plasma protein profiles can reflect physiological or pathological conditions associated with many human diseases, making blood the most important fluid for clinical diagnostics2-4. Nevertheless, only a handful of plasma proteins are utilized in routine clinical tests. This is due to a host of reasons, including the intrinsic complexity of the plasma proteome1, the heterogeneity of human diseases and the fast kinetics associated with protein degradation in sampled blood5. Simple technologies that can sensitively sample large numbers of proteins over broad concentration ranges, from small amounts of blood, and within minutes of sample collection, would assist in solving these problems. Herein, we report on an integrated microfluidic system, called the Integrated Blood Barcode Chip (IBBC). It enables on-chip blood separation and the rapid measurement of a panel of plasma proteins from small quantities of blood samples including a fingerprick of whole blood. This platform holds potential for inexpensive, non-invasive, and informative clinical diagnoses, particularly, for point-of-care. PMID:19029914

  9. Haematological changes in the laboratory rat Rattus norvegicus infected with Echinostoma caproni (Trematoda: Echinostomatidae).

    PubMed

    Muñoz-Antoli, C; Cortés, A; Torres, D; Esteban, J G; Toledo, R

    2015-09-01

    To study possible indirect effects of the infection with intestinal helminths, 12 Rattus norvegicus (Wistar) were each experimentally exposed to 100 metacercariae of Echinostoma caproni, and blood samples were taken weekly up to 4 weeks post-exposure for comparison with control rats. Values of haematocrit (HCT), red blood cells (RBC), platelets (PLT), white blood cells (WBC), haemoglobin (HGB) and haematimatrix indices, and mean corpuscular haemoglobin concentrations (MCHC) were determined. In addition, leucocyte counts, including lymphocytes, neutrophils, monocytes, eosinophils and basophils were analysed. These parameters, including the leucocyte counts, showed no significant differences, except for MCHC at 4 weeks post-exposure. The present results indicate that in rats infected with E. caproni, although eosinophilia did not significantly increase, a significant reduction in MCHC was associated with an increase in the number of RBC.

  10. Hemoglobin Adducts of Benzene Oxide in Neonatal and Adult Dried Blood Spots

    PubMed Central

    Funk, William E.; Waidyanatha, Suramya; Chaing, Shu H.; Rappaport, Stephen M.

    2010-01-01

    Adducts of reactive chemicals with hemoglobin (Hb) or human serum albumin can be used as biomarkers of internal doses of carcinogens. Since dried blood spots (DBS) are easier to collect and store than conventional venous blood samples, they encourage applications of biomarkers of exposure in large epidemiology studies. Also, neonatal DBS can be used to investigate chemical exposures in utero. Here, we report a simple method to isolate Hb from DBS with high recovery and purity using the addition of ethanol to aqueous DBS extracts. To prove the concept that DBS-derived proteins can be used to assay for adducts, we measured Hb adducts of benzene oxide, a reactive metabolite of the ubiquitous air pollutant, benzene, in 9 neonatal and 9 adult DBS (from volunteer subjects), using a gas chromatography-mass spectrometry method that we had previously developed. For comparison, benzene oxide-Hb adducts (BO-Hb) were measured in the same 9 adult subjects, using Hb that had been isolated and purified using our conventional method for venous blood. The geometric mean BO-Hb levels in all DBS samples ranged from 27.7 to 33.1 pmol/g globin. Neither of the comparisons of mean (logged) BO-Hb levels between sources (adult conventional vs. adult DBS and adult DBS vs. newborn DBS) showed a significant difference. Based upon the estimated variance of the BO-Hb levels, we had 80% power to detect a 1.7-fold difference in geometric mean levels of BO-Hb in our samples of 9 subjects. PMID:18708378

  11. No positive influence of ingesting chia seed oil on human running performance.

    PubMed

    Nieman, David C; Gillitt, Nicholas D; Meaney, Mary Pat; Dew, Dustin A

    2015-05-15

    Runners (n = 24) reported to the laboratory in an overnight fasted state at 8:00 am on two occasions separated by at least two weeks. After providing a blood sample at 8:00 am, subjects ingested 0.5 liters flavored water alone or 0.5 liters water with 7 kcal kg-1 chia seed oil (random order), provided another blood sample at 8:30 am, and then started running to exhaustion (~70% VO2max). Additional blood samples were collected immediately post- and 1-h post-exercise. Despite elevations in plasma alpha-linolenic acid (ALA) during the chia seed oil (337%) versus water trial (35%) (70.8 ± 8.6, 20.3 ± 1.8 μg mL(-1), respectively, p < 0.001), run time to exhaustion did not differ between trials (1.86 ± 0.10, 1.91 ± 0.13 h, p = 0.577, respectively). No trial differences were found for respiratory exchange ratio (RER) (0.92 ± 0.01), oxygen consumption, ventilation, ratings of perceived exertion (RPE), and plasma glucose and blood lactate. Significant post-run increases were measured for total leukocyte counts, plasma cortisol, and plasma cytokines (Interleukin-6 (IL-6), Interleukin-8 (IL-8), Interleukin-10 (IL-10), and Tumor necrosis factors-α (TNF-α)), with no trial differences. Chia seed oil supplementation compared to water alone in overnight fasted runners before and during prolonged, intensive running caused an elevation in plasma ALA, but did not enhance run time to exhaustion, alter RER, or counter elevations in cortisol and inflammatory outcome measures.

  12. Inhibition of recombinase polymerase amplification by background DNA: a lateral flow-based method for enriching target DNA.

    PubMed

    Rohrman, Brittany; Richards-Kortum, Rebecca

    2015-02-03

    Recombinase polymerase amplification (RPA) may be used to detect a variety of pathogens, often after minimal sample preparation. However, previous work has shown that whole blood inhibits RPA. In this paper, we show that the concentrations of background DNA found in whole blood prevent the amplification of target DNA by RPA. First, using an HIV-1 RPA assay with known concentrations of nonspecific background DNA, we show that RPA tolerates more background DNA when higher HIV-1 target concentrations are present. Then, using three additional assays, we demonstrate that the maximum amount of background DNA that may be tolerated in RPA reactions depends on the DNA sequences used in the assay. We also show that changing the RPA reaction conditions, such as incubation time and primer concentration, has little effect on the ability of RPA to function when high concentrations of background DNA are present. Finally, we develop and characterize a lateral flow-based method for enriching the target DNA concentration relative to the background DNA concentration. This sample processing method enables RPA of 10(4) copies of HIV-1 DNA in a background of 0-14 μg of background DNA. Without lateral flow sample enrichment, the maximum amount of background DNA tolerated is 2 μg when 10(6) copies of HIV-1 DNA are present. This method requires no heating or other external equipment, may be integrated with upstream DNA extraction and purification processes, is compatible with the components of lysed blood, and has the potential to detect HIV-1 DNA in infant whole blood with high proviral loads.

  13. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  14. Whole blood analysis rotor assembly having removable cellular sedimentation bowl

    DOEpatents

    Burtis, C.A.; Johnson, W.F.

    1975-08-26

    A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)

  15. The continuing impact of lead dust on children's blood lead: comparison of public and private properties in New Orleans.

    PubMed

    Mielke, Howard W; Gonzales, Chris R; Mielke, Paul W

    2011-11-01

    Compared with a maximum collective lead (Pb) estimate of ∼1811 metric tons (MT) in exterior paint on 86,000 New Orleans houses, Pb additives in gasoline were estimated at ∼12,000 MT in New Orleans, yielding ∼9100 MT Pb exhausted as aerosols from vehicles; ∼4850 MT were particles>10 μm and ∼4200 MT were particles <0.25 μm. To evaluate pre-Hurricane Katrina soil Pb and children's blood Pb at public housing and private residential properties in the inner-city compared with the outer city of New Orleans. This study includes 224 soil samples from 10 public housing properties and 363 soil samples from residential private properties within an 800 m radius of centroids of public housing census tracts. The Louisiana Childhood Lead Poisoning Prevention Program data from 2000 to 2005 (pre-Hurricane Katrina) was the source for 9807 children's blood Pb (μg/dL) results. Soil and blood Pb data were grouped by public housing census tracts and private residential properties. This study uses Multi-Response Permutation Procedures for statistical analysis. Brick public properties in the city core had significantly more soil Pb contamination and higher prevalence of elevated children's blood Pb than same-aged brick public properties in the outer areas of the city. The pre-Hurricane Katrina New Orleans concentration of Pb dust in the inner-city soil displayed a median of 438 mg/kg or 3.7 times larger than Pb dust in outlying areas where the median soil Pb was 117 mg/kg (p-value=2.9×10(-15)). Also, the pre-Hurricane Katrina prevalence of children's blood Pb≥10 μg/dL was 22.9% within the inner-city compared with 9.1% in the outer areas of New Orleans (p-value=3.4×10(-74)). Comparing the quantities of Pb dust from paint and Pb additives to gasoline, this study supports the later source as a more plausible explanation for the differences in soil Pb and children's blood Pb within public and private housing in the higher traffic congested inner-city core compared with the lower traffic congested outer areas of New Orleans. Similar patterns of environmental Pb dust contamination and childhood Pb exposure are expected in all cities. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Mechanisms of red blood cells agglutination in antibody-treated paper.

    PubMed

    Jarujamrus, Purim; Tian, Junfei; Li, Xu; Siripinyanond, Atitaya; Shiowatana, Juwadee; Shen, Wei

    2012-05-07

    Recent reports on using bio-active paper and bio-active thread to determine human blood type have shown a tremendous potential of using these low-cost materials to build bio-sensors for blood diagnosis. In this work we focus on understanding the mechanisms of red blood cell agglutination in the antibody-loaded paper. We semi-quantitatively evaluate the percentage of antibody molecules that are adsorbed on cellulose fibres and can potentially immobilize red blood cells on the fibre surface, and the percentage of the molecules that can desorb from the cellulose fibre surface into the blood sample and cause haemagglutination reaction in the bulk of a blood sample. Our results show that 34 to 42% of antibody molecules in the papers treated with commercial blood grouping antibodies can desorb from the fibre surface. When specific antibody molecules are released into the blood sample via desorption, haemagglutination reaction occurs in the blood sample. The reaction bridges the red cells in the blood sample bulk to the layer of red cells immobilized on the fibre surface by the adsorbed antibody molecules. The desorbed antibody also causes agglutinated lumps of red blood cells to form. These lumps cannot pass through the pores of the filter paper. The immobilization and filtration of agglutinated red cells give reproducible identification of positive haemagglutination reaction. Results from this study provide information for designing new bio-active paper-based devices for human blood typing with improved sensitivity and specificity.

  17. Environmental health collaboration: United States and Russia.

    PubMed

    Rubin, C H; Jones, R L; Revich, B; Avaliani, S L; Gurvich, E

    2003-08-01

    Developed nations share similar challenges to human health from commercial and agricultural chemicals that are released into the environment. Although Russia and the United States are historically distinct and unique, both countries are geographically large and economically dependent on emission-producing surface transportation. This paper describes U.S.-Russian collaborative activities that grew from a 1995 conference in Moscow that brought together environmental health investigators from both countries to discuss common concerns about the human health impact of environmental pollutants. Lead, pesticides, volatile organic compounds, and mercury were identified as contaminants of greatest concern. Collaborative studies were initiated that included collecting blood and hair samples and splitting samples for analyses in both countries, and introducing and sharing new portable blood and environmental sample analyses instruments. The findings demonstrated that hair analysis was not a good predictor of BLL and that Russian children in the first city sampled had a mean BLL of 7.7 microg/dl. Although higher than the U.S. mean, this level was below the 10.0 microg/dl CDC level of concern. This manuscript summarizes additional study results and describes their impacts on Russian policy. On-going collaborative environmental investigations are described.

  18. From IEDs to AIDS? Detection of HIV in human corpses by rapid screening tests after suspected intentional transmission in terrorist attacks.

    PubMed

    Frickmann, Hagen; Wulff, B; Loderstædt, U; Hagen, R M; Sturm, D; Polywka, S

    2013-12-01

    We evaluated the feasibility of intentional transmission of HIV by means of suicide bombing and rape as a terrorist tactic in asymmetric conflicts by evaluating the recognised optimum conditions for biological warfare. We also estimated the suitability of a fourth-generation rapid test for HIV detection in the blood of dead terrorists killed in the completion of their mission. The feasibility of deliberate transmission of HIV for terroristic ends was evaluated on the basis of published experience from passive biological warfare research. In addition, blood from four recently deceased HIV-positive patients and four HIV-negative control corpses, stored at 4°C in a mortuary, was analysed at 12, 24, 36 and 48 h postmortem by rapid serological testing. The feasibility of HIV infection for terroristic purposes was established. The fourth-generation HIV rapid test we evaluated identified all HIV-positive samples and was negative for all HIV-negative samples. Rapid HIV testing from the remains of dead terrorists in the deployed military environment is possible. Samples should be acquired quickly, basic sample preparation is advisable and consequent decisions concerning postexposure prophylaxis should take into account the diagnostic gap in early infections.

  19. The application of silicon sol-gel technology to forensic blood substitute development: Mimicking aspects of whole human blood rheology.

    PubMed

    Stotesbury, Theresa; Illes, Mike; Wilson, Paul; Vreugdenhil, Andrew J

    2017-01-01

    Solution-gelation chemistry has promising applications in forensic synthetic blood substitute development. This research offers a silicon-based sol-gel approach to creating stable materials that share similar rheological properties to that of whole human blood samples. Room temperature, high water content, silicon sol-gels were created using the organosilane precursors 3-glycidoxypropyltrimethoxysilane and tetraethylorthosilicate along with various concentrations of filler and pigment. Shear-thinning non-Newtonian properties were observed within most formulations of the presented materials. The effects of colloidal concentration, temperature, age and filler addition on the viscosity of the sol-gels were investigated. SEM-EDS analysis was used to identify the behavior of the fillers within the film and support their inclusion for basic bloodstain pattern simulation. A final proposed candidate sol-gel was assessed using a previously reported passive drip simulation test on a hard, dry surface and passed. This works represents encouraging development in providing safe material alternatives to using whole human blood for forensic training and research. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Simple and Inexpensive Quantification of Ammonia in Whole Blood

    PubMed Central

    Ayyub, Omar B.; Behrens, Adam M.; Heligman, Brian T.; Natoli, Mary E.; Ayoub, Joseph J.; Cunningham, Gary; Summar, Marshall; Kofinas, Peter

    2015-01-01

    Quantification of ammonia in whole blood has applications in the diagnosis and management of many hepatic diseases, including cirrhosis and rare urea cycle disorders, amounting to more than 5 million patients in the United States. Current techniques for ammonia measurement suffer from limited range, poor resolution, false positives or large, complex sensor set-ups. Here we demonstrate a technique utilizing inexpensive reagents and simple methods for quantifying ammonia in 100 μl of whole blood. The sensor comprises a modified form of the indophenol reaction, which resists sources of destructive interference in blood, in conjunction with a cation-exchange membrane. The presented sensing scheme is selective against other amine containing molecules such as amino acids and has a shelf life of at least 50 days. Additionally, the resulting system has high sensitivity and allows for the accurate reliable quantification of ammonia in whole human blood samples at a minimum range of 25 to 500 μM, which is clinically for rare hyperammonemic disorders and liver disease. Furthermore, concentrations of 50 and 100 μM ammonia could be reliably discerned with p=0.0001. PMID:25936660

Top