Science.gov

Sample records for additional diagnostic procedures

  1. Astigmatism and diagnostic procedures.

    PubMed

    Visnjić, Mirna Belovari; Zrinsćak, Ognjen; Barisić, Freja; Iveković, Renata; Laus, Katia Novak; Mandić, Zdravko

    2012-06-01

    Astigmatism represents an inability of the cornea and lens to provide a sharp image onto the retina. Correcting astigmatic errors, whether congenital, contact lens induced or surgically induced, is now an integral part of modern cataract and refractive procedures. Development of modern technology has enabled accurate diagnosis and perfect opportunities for correction; however, while cataract and keratorefractive surgery have come a long way in the last decade, the treatment and diagnosis of astigmatism continue to challenge ophthalmologists. There are several diagnostic procedures and tools available today, some standard and some contemporary that include keratometry, corneal topography, apparatus using wavefront or Scheimpflug analysis like Orbscan, Pentacam, Wavescan, etc. With the introduction of several new diagnostic tools, measurements of astigmatism have become less of an issue, but in some cases it is still difficult to obtain consistent results. What remains still unanswered is the question of the best diagnostic tool on the market. Further research is needed to evaluate both tools as well as their clinical application for optimal use. PMID:23115957

  2. Diagnostic Procedures of Itch.

    PubMed

    Reich, Adam; Szepietowski, Jacek C

    2016-01-01

    A complex and multifactorial pathogenesis of itch makes the proper diagnosis of underlying disease a difficult and challenging clinical problem. The examination of every patient with itch should be started by gathering an accurate history. During the anamnesis it is important to obtain data about the beginning of the appearance of symptoms, its location, diurnal variation, and the factors influencing itch perception. After careful anamnesis the patient should undergo a detailed physical examination, with particular attention to the skin in order to look for any signs of skin lesions. Special attention should be paid to distinguish the primary lesion from the changes resulting from scratching. In patients in whom the etiology of the itch cannot be identified on the basis of the medical examination, a panel of primary screen laboratory examination may be required, and if necessary, depending on the results of basic laboratory results and data from medical history, additional diagnostic tests should be considered. In patients in whom an organic cause of itching has not been established, itch is most likely of undetermined origin; however, psychogenic causes should also be suspected and ruled out. In conclusion, it could be stated that itch is a common symptom of many skin diseases, systemic of neurological diseases. Despite the complex etiology of the disease, an exact cause of itch should be searched for in each patient, as successful therapy is largely dependent on the determination of the cause of the itching. PMID:27578067

  3. [Costing nuclear medicine diagnostic procedures].

    PubMed

    Markou, Pavlos

    2005-01-01

    To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges. PMID:15886748

  4. Diagnostic Procedures in Parasitic Diseases

    PubMed Central

    Seah, S. K. K.

    1976-01-01

    This article offers some guidelines for investigating patients with suspected tropical and parasitic diseases. The common symptoms of tropical diseases as seen in Canadians returning from the tropics are discussed and diagnostic approaches suggested. Simple office laboratory procedures for the diagnosis of the common intestinal and blood parasites are outlined. The value and pitfalls of serological tests in parasitic diseases are discussed. ImagesFigure 1Figure 2 PMID:21308049

  5. Caustic addition system operability test procedure

    SciTech Connect

    Parazin, R.E.

    1994-11-01

    This test procedure provides instructions for performing operational testing of the major components of the 241-AN-107 Caustic Addition System by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E).

  6. Diagnostic Procedures to Detect Chlamydia trachomatis Infections.

    PubMed

    Meyer, Thomas

    2016-08-05

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  7. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    PubMed Central

    Meyer, Thomas

    2016-01-01

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections. PMID:27681919

  8. Diagnostic Procedures to Detect Chlamydia trachomatis Infections.

    PubMed

    Meyer, Thomas

    2016-01-01

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections. PMID:27681919

  9. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    PubMed Central

    Meyer, Thomas

    2016-01-01

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  10. Psychoeducational Diagnostic Services for Learning Disabled Youths. Research Procedures.

    ERIC Educational Resources Information Center

    Barrows, Thomas S.; And Others

    A detailed explicit definition of learning disability (LD) is presented in terms of the diagnostic procedures and decision points used in identifying that category among a group of juvenile delinquent and control group adolescent males. The described procedures include a review of existing records, interviews, and diagnostic assessments.…

  11. Cancer Risks Associated with External Radiation From Diagnostic Imaging Procedures

    PubMed Central

    Linet, Martha S.; Slovis, Thomas L.; Miller, Donald L.; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; de Gonzalez, Amy Berrington

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate widespread use of evidence-based appropriateness criteria for decisions about imaging procedures, oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives, development of electronic lifetime records of imaging procedures for patients and their physicians, and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. PMID:22307864

  12. Dynamic diagnostic and decision procedures under uncertainty

    SciTech Connect

    Baranov, V.V.

    1995-01-01

    In this paper, we consider uncertainty that arises when the true state x {element_of} E is not accessible to direct observation and remains unknown. Instead, we observe some features {theta} {element_of} {Theta} that carry a certain information about the true state. This information is described by the conditional distribution P({Theta}{vert_bar}E), which we call the linkage distribution. Regarding this distribution we assume that it exists but is unknown. This leads to uncertainty with respect to states from E and the linkage distribution P({Theta}{vert_bar}E), which we denote by NEP. The substantive problem can be stated as follows: from observations of the features {theta}{element_of}{Theta} made at each time instant n = 1,2,...,recognize the state x {element_of} E, identify the linkage distribution P, and use the results of recognition and identification to choose a decision y {element_of} Y so that the decision process is optimal in some sense. State recognition is the subject of diagnostics. The uncertainty NEP thus generates a problem of diagnostics and dynamic decision making.

  13. [Takayasu disease. Diagnostic criteria and therapeutic procedure].

    PubMed

    Masmoudi, S; Frikha, I; Gdoura, M; Zouari, M H; Mnif, J; Sahnoun, Y

    1992-10-01

    A study of 11 cases of Takayasu's disease, collected from the cardio-vascular surgical service of Sfax, has been realized during the 4 year-period from 1988 to 1991. Womanly predominance was neat. The average age was 40 years, with extremes of 24 and 56 years. Dominant revealing symptoms was upper limb ischaemia found in 9 cases, a reno-vascular hypertension rebelled to medical treatment was noted in 2 cases. Arteriography have showed a preferential localization of lesions in the subclavian artery essentially at the post-vertebral segment. Lesions types were dominated by stenosis and obliteration, then aneurysms were rare. Operative indication was posed in 9 cases. 11 revascularisations procedures were performed of which 10 arterial by passes and one resection graft. Two bypasses were obstructed, the 9 remaining bypasses have a good previous checked clinically and by angiography (or echo-doppler) with a mean follow-up of 14 months.

  14. Cardiovascular procedures/diagnostic techniques and therapeutic procedures

    SciTech Connect

    Tilkian, A.G.; Daily, E.K.

    1986-01-01

    This book covers the technical and therapeutic aspects of cardiovascular procedures in immense detail. There are large and appropriate diagrams and tables. The topics of the chapters are tools for catheterization, venous access, arterial access, hemodynamic monitoring, cardiac catheterization and coronary arteriography, ergonovine provocation testing for coronary artery spasm, pulmonary angiography, endomyocredial biopsy, electrophysiologic studies, pericardiocentesis and drainage, intraaortic balloon pumping, direct current cardioversion and defibrilaltion, pacemaker implantation of the automatic implantable cardioverter/defibrillator, coronary angioplasty, thrombolytic therapy, transluminal catheter extraction and resolution of intracardiac catheter knots, cardiopulmonary resuscitation, contrast media toxicity and allergic reactions, radiation hazards, and medicolegal concerns. An appendix and index follow these chapters. In general, each chapter covers historical aspects, indications, complications, techniques, and preoperative and postoperative care.

  15. Diagnostic procedures for submucosal tumors in the gastrointestinal tract

    PubMed Central

    Ponsaing, Laura Graves; Kiss, Katalin; Loft, Annika; Jensen, Lise Ingemann; Hansen, Mark Berner

    2007-01-01

    This review is part one of three, which will present an update on diagnostic procedures for gastrointestinal (GI) submucosal tumors (SMTs). Part two identifies the classification and part three the therapeutic methods regarding GI SMTs. Submucosal tumors are typically asymptomatic and therefore encountered incidentally. Advances in diagnostic tools for gastrointestinal submucosal tumors have emerged over the past decade. The aim of this paper is to provide the readers with guidelines for the use of diagnostic procedures, when a submucosal tumor is suspected. Literature searches were performed to find information on diagnostics for gastrointestinal submucosal tumors. Based on the searches, the optimal diagnostic procedures and specific features of the submucosal tumors could be outlined. Standard endoscppy, capsule endoscopy and push-and-pull enteroscopy (PPE) together with barium contrast X-ray do not alone provide sufficient information, when examining submucosal tumors. Endoscopic ultrasound (EUS), computed tomography (CT), magnetic resonance imaging (MRI) and fluorodeoxyglucose-labeled positron emission tomography (FDG-PET) are recommended as supplementary tools. PMID:17659668

  16. Diagnostic Procedures for Detecting Nonlinear Relationships between Latent Variables

    ERIC Educational Resources Information Center

    Bauer, Daniel J.; Baldasaro, Ruth E.; Gottfredson, Nisha C.

    2012-01-01

    Structural equation models are commonly used to estimate relationships between latent variables. Almost universally, the fitted models specify that these relationships are linear in form. This assumption is rarely checked empirically, largely for lack of appropriate diagnostic techniques. This article presents and evaluates two procedures that can…

  17. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  18. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  19. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  20. 5 CFR 179.309 - Additional administrative procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Additional administrative procedures. 179.309 Section 179.309 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.309 Additional administrative procedures....

  1. Physician Knowledge of Risks of Surgical and Invasive Diagnostic Procedures

    PubMed Central

    Phillips, William R.; Kronlund, Scott F.

    1985-01-01

    Knowledge of the rates of major complications of surgical and invasive diagnostic procedures is essential to effective clinical decision making. A mail survey of 128 family or general physicians and general surgeons in Washington state tested their knowledge of the rates of death and major complications for ten procedures. Overall accuracy of physician knowledge was low, with 27% of responses correct, 26% underestimates, 27% overestimates and 21% admitting no knowledge. No significant differences in accuracy were found between specialty groups. Few associations were found between accuracy and physician board certification, years in practice or performance of the procedure. For every complication, many physicians made underestimation or overestimation errors by several orders of magnitude and a few consistently denied existence of any risk. Physicians could improve their knowledge of the rates of complications associated with procedures they carry out. PMID:4013275

  2. 29 CFR 1911.4 - Additional or alternative procedural requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Additional or alternative procedural requirements. 1911.4 Section 1911.4 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) RULES OF PROCEDURE FOR PROMULGATING, MODIFYING, OR...

  3. [List of diagnostic tests and procedures in leg ulcer].

    PubMed

    Spoljar, Sanja

    2013-10-01

    Many factors contribute to the pathogenesis of leg ulcer. Most patients have venous leg ulcer due to chronic venous insufficiency. Less often, patients have arterial leg ulcer resulting from peripheral arterial occlusive disease, the most common cause of which is arteriosclerosis. Leg ulcer may be of a mixed arteriovenous origin. In diabetic patients, distal symmetric neuropathy and peripheral vascular disease are probably the most important etiologic factors in the development of diabetic leg ulcer. Other causes of chronic leg ulcers are hematologic diseases, autoimmune diseases, genetic defects, infectious diseases, primary skin diseases, cutaneous malignant diseases, use of some medications and therapeutic procedures, and numerous exogenous factors. Diagnosis of leg ulcer is based on medical history, inspection, palpation of skin temperature, palpation of arteries, fascia holes, presence and degree of edema, firm painful cords, and functional testing to assess peripheral occlusive arterial disease or identify superficial and deep venous reflux of the legs. Knowledge of differential diagnosis is essential for ensuring treatment success in patients with leg ulcer. There are many possible etiologic factors of leg ulcers and sometimes, clinical findings are similar. Additional testing should be performed, e.g., serologic testing such as blood count, C-reactive protein, HBA1c, erythrocyte sedimentation rate, differential blood count, total proteins, electrolytes, coagulation parameters, circulating immune complex, cryoglobulins, homocysteins, AT, PAI-1, APC resistance, proteins C and S, paraproteins, ANA, ENA, ANCA, dsDNA, antiphospholipid antibodies, urea, creatinine, blood lipids, vitamins and trace elements. Also, biopsy of the lesion for histopathology, direct immunofluorescence, bacteriology and mycology should be included. Other tests are Raynaud (cold stimulation) test and pathergy test. Device-based diagnostic testing should be performed for future

  4. [Diagnostic invasive procedures in the diagnosis of primary lung cancer. Diagnostic value and complications].

    PubMed

    Almind, M; Faurschou, P; Viskum, K

    1996-12-30

    The invasive procedures used in the diagnosis of primary lung cancer are reviewed based on the literature. The choice of method should be related to its diagnostic accuracy, complications and cost. The chest x-ray provides the background for the further choice of diagnostic method. In central tumors, bronchoscopy meets the requirements and in peripheral lesions percutaneous transthoracic needle biopsy fulfils the conditions. In some centres, mediastinoscopy is preferred in all cases preoperatively, while others only perform this examination if a CT-scan shows mediastinal lymph nodes larger than 1 cm in diameter. If the latter procedure is followed, 10-30% of the patients will have lymph node metastases. Thoracoscopy is used when a pleural effusion remains undiagnosed after pleuracentesis. A considerable amount of patients will be shown to have pleural neoplastic spread even though cytological examination of the pleural fluid did not demonstrate malignant cells. The complication rates in all methods are low. PMID:9012072

  5. [ENDOCYTOSCOPY--NOVEL ENDOSCOPIC DIAGNOSTICS APPROACH: PRINCIPLES AND PROCEDURE].

    PubMed

    Pirogov, S S; Sokolov, V V; Kaprin, A D; Volchenko, N N; Karpova, E S; Pavlov, P V; Sukhin, D G; Pogorelov, N N; Ryabov, A B; Khomyakov, V M; Chulikov, I A

    2015-01-01

    Endocytoscopy is one of the most novel endoscopic diagnostic procedures, providing optical magnification up to 1150 times of gastrointestinal and respiratory tract mucosa. Such approach allows real-time tissue and cellular structure visualization. Endocytoscopy, along with confocal laser endomicroscopy, can be considered as "optical biopsy" in vivo. Of course, endocytoscopy currently is experimental diagnostic method, all available endocytoscopes are prototypes. According to published data, endocytoscopy can be used in precancerous conditions and early intramucosal cancer diagnostics in esophagus, stomach, colon and bronchial tree. Different types of endocytoscopes are used for examinations: some of them are baby-scopes, with fixed magnification 570-1150 times, introduced into accessory channel of the therapeutic parent-endoscope, others--are integrated type, providing scalable magnification from 80 to 380 times. As for traditional pathology ex vivo, for endocytoscopy mucosal cell nuclei stain is needed. For vital staining during endocytoscopy methylene blue, toluidine blue and crystal violet in different concentrations are more often used. In cases of squamous-cell dysplasia or cancer, it is recommended to use 1% methylene blue solution, whereas in intestinal type metaplasia, dysplastic changes and cancer (Barrett's esophagus, P. Correa precancerous cascade, colon adenomas), 1% toluidine blue is preferred. With endocytoscopy, after vital staining, we can visualize and estimate mucosa tissue and cell characteristics: papillae, crypt and gland shapes and sizes, their integrity (tissue markers); cell nuclei size and shape, polarity and nuclear dye intensity (cell markers). PMID:26415259

  6. Patient dose measurements in diagnostic radiology procedures in Montenegro.

    PubMed

    Milatović, Aleksandra; Ciraj-Bjelac, Olivera; Ivanović, Sonja; Jovanović, Slobodan; Spasić-Jokić, Vesna

    2012-05-01

    It was the aim of the study presented here to estimate for the first time patient dose levels in conventional diagnostic radiology in Montenegro. Measurements of patient dose in terms of entrance surface air kerma (ESAK) and kerma-area product (KAP) were performed on at least 10 patients for each examination type, in each of five randomly selected health institutions in Montenegro, so that a total of 872 patients for 16 different examination categories were included in the survey (817 patients for 1049 radiographies and 55 fluoroscopy patients). Exposure settings and individual data were recorded for each patient. Mean, median and third quartile values ESAK of patient doses are reported. The estimated mean ESAK values obtained are as follows: 4.7 mGy for pelvis anteroposterior (AP), 4.5 mGy for lumbar spine AP, 7.8 mGy for lumbar spine lateral (LAT), 3.1 mGy for thoracic spine AP and 4.3 mGy for thoracic spine LAT. When compared with the European diagnostic reference values, the mean ESAK for all studied examination types are found to be below the reference levels, except in chest radiography. Mean ESAK values for chest radiography are 0.9 mGy for posteroanterior (PA) projection and 2.0 mGy for LAT. The results exhibit a wide range of variation. For fluoroscopy examinations, the total KAP was measured. The mean KAP value per procedure for barium meal is found to be 22 Gy cm(2), 41 Gy cm(2) for barium enema and 19 Gy cm(2) for intravenous urography. Broad dose ranges for the same types of examinations indicate the necessity of applying practice optimisation in diagnostic radiology and establishment of national diagnostic reference levels.

  7. Test Procedure - pumping system for caustic addition project

    SciTech Connect

    Leshikar, G.A.

    1994-10-01

    This test procedure provides the requirements for sub-system testing and integrated operational testing of the submersible mixer pump and caustic addition equipment by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E).

  8. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 1 2012-07-01 2012-07-01 false Additional Procedural Guidance A Appendix A to Part 155 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE SECURITY DEFENSE... Guidance 1. When the DISCO cannot affirmatively find that it is clearly consistent with the...

  9. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 1 2011-07-01 2011-07-01 false Additional Procedural Guidance A Appendix A to Part 155 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE SECURITY DEFENSE... Guidance 1. When the DISCO cannot affirmatively find that it is clearly consistent with the...

  10. Neonatal Cholestasis – Differential Diagnoses, Current Diagnostic Procedures, and Treatment

    PubMed Central

    Götze, Thomas; Blessing, Holger; Grillhösl, Christian; Gerner, Patrick; Hoerning, André

    2015-01-01

    Cholestatic jaundice in early infancy is a complex diagnostic problem. Misdiagnosis of cholestasis as physiologic jaundice delays the identification of severe liver diseases. In the majority of infants, prolonged physiologic jaundice represent benign cases of breast milk jaundice, but few among them are masked and caused by neonatal cholestasis (NC) that requires a prompt diagnosis and treatment. Therefore, a prolonged neonatal jaundice, longer than 2 weeks after birth, must always be investigated because an early diagnosis is essential for appropriate management. To rapidly identify the cases with cholestatic jaundice, the conjugated bilirubin needs to be determined in any infant presenting with prolonged jaundice at 14 days of age with or without depigmented stool. Once NC is confirmed, a systematic approach is the key to reliably achieve the diagnosis in order to promptly initiate the specific, and in many cases, life-saving therapy. This strategy is most important to promptly identify and treat infants with biliary atresia, the most common cause of NC, as this requires a hepatoportoenterostomy as soon as possible. Here, we provide a detailed work-up approach including initial treatment recommendations and a clinically oriented overview of possible differential diagnoses in order to facilitate the early recognition and a timely diagnosis of cholestasis. This approach warrants a broad spectrum of diagnostic procedures and investigations including new methods that are described in this review. PMID:26137452

  11. 78 FR 20103 - Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... AGENCY Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures AGENCY..., on Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures. This document is... for Diagnostic X-rays,'' which was released in October 1976. The recommendations contained in...

  12. Eating Disorder Diagnostic Scale: Additional Evidence of Reliability and Validity

    ERIC Educational Resources Information Center

    Stice, Eric; Fisher, Melissa; Martinez, Erin

    2004-01-01

    The authors conducted 4 studies investigating the reliability and validity of the Eating Disorder Diagnostic Scale (HDDS; E. Stice, C. F. Telch, & S. L. Rizvi, 2000), a brief self-report measure for diagnosing anorexia nervosa, bulimia nervosa, and binge eating disorder. Study 1 found that the HDDS showed criterion validity with interview-based…

  13. A Complete Molecular Diagnostic Procedure for Applications in Surveillance and Subtyping of Avian Influenza Virus

    PubMed Central

    Tseng, Chun-Hsien; Tsai, Hsiang-Jung; Chang, Chung-Ming

    2014-01-01

    Introduction. The following complete molecular diagnostic procedure we developed, based on real-time quantitative PCR and traditional PCR, is effective for avian influenza surveillance, virus subtyping, and viral genome sequencing. Method. This study provides a specific and sensitive step-by-step procedure for efficient avian influenza identification of 16 hemagglutinin and 9 neuraminidase avian influenza subtypes. Result and Conclusion. This diagnostic procedure may prove exceedingly useful for virological and ecological advancements in global avian influenza research. PMID:25057497

  14. Effects on Diagnostic Parameters After Removing Additional Synchronous Gear Meshes

    NASA Technical Reports Server (NTRS)

    Decker, Harry J.

    2003-01-01

    Gear cracks are typically difficult to diagnose with sufficient time before catastrophic damage occurs. Significant damage must be present before algorithms appear to be able to detect the damage. Frequently there are multiple gear meshes on a single shaft. Since they are all synchronous with the shaft frequency, the commonly used synchronous averaging technique is ineffective in removing other gear mesh effects. Carefully applying a filter to these extraneous gear mesh frequencies can reduce the overall vibration signal and increase the accuracy of commonly used vibration metrics. The vibration signals from three seeded fault tests were analyzed using this filtering procedure. Both the filtered and unfiltered vibration signals were then analyzed using commonly used fault detection metrics and compared. The tests were conducted on aerospace quality spur gears in a test rig. The tests were conducted at speeds ranging from 2500 to 5000 revolutions per minute and torques from 184 to 228 percent of design load. The inability to detect these cracks with high confidence results from the high loading which is causing fast fracture as opposed to stable crack growth. The results indicate that these techniques do not currently produce an indication of damage that significantly exceeds experimental scatter.

  15. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for...

  16. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for...

  17. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for...

  18. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for...

  19. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for...

  20. [Influence of dry eye syndrome on glaucoma diagnostic procedures].

    PubMed

    Rüfer, F; Erb, C

    2012-11-01

    Approximately 50-60% of primary open angle glaucoma patients suffer from dry eye and ocular surface disease and have a reduced corneal thickness. The measurements by imaging procedures are weakened by signal noise and perimetry procedures are affected by generalized loss of sensitivity. In dry eye patients, possible influences on new perimetry procedures, such as frequency doubling technology (FDT), flicker-defined form (FDF) perimetry and pulsar perimetry (PP) potentially result from stray light and reduced contrast sensitivity. In glaucoma patients with ocular surface disturbances, measuring procedures with high sensitivity and low specificity should be carefully checked for plausibility by the examiner. Using these procedures uncritically involves the danger of over interpretation in terms of non-existent glaucoma progression. If necessary, eyes should be pretreated with lubricating eye drops or therapy should be switched to preservative-free pressure lowering drops. Afterwards, new control measurements should be taken to exclude glaucoma pseudoprogression. PMID:23179813

  1. Diagnosing Crohn's disease: an economic analysis comparing wireless capsule endoscopy with traditional diagnostic procedures.

    PubMed

    Goldfarb, Neil I; Pizzi, Laura T; Fuhr, Joseph P; Salvador, Christopher; Sikirica, Vanja; Kornbluth, Asher; Lewis, Blair

    2004-01-01

    The purpose of this study was to review economic considerations related to establishing a diagnosis of Crohn's disease, and to compare the costs of a diagnostic algorithm incorporating wireless capsule endoscopy (WCE) with the current algorithm for diagnosing Crohn's disease suspected in the small bowel. Published literature, clinical trial data on WCE in comparison to other diagnostic tools, and input from clinical experts were used as data sources for (1) identifying contributors to the costs of diagnosing Crohn's disease; (2) exploring where WCE should be placed within the diagnostic algorithm for Crohn's; and (3) constructing decision tree models with sensitivity analyses to explore costs (from a payor perspective) of diagnosing Crohn's disease using WCE compared to other diagnostic methods. Literature review confirms that Crohn's disease is a significant and growing public health concern from clinical, humanistic and economic perspectives, and results in a long-term burden for patients, their families, providers, insurers, and employers. Common diagnostic procedures include radiologic studies such as small bowel follow through (SBFT), enteroclysis, CT scans, ultrasounds, and MRIs, as well as serologic testing, and various forms of endoscopy. Diagnostic costs for Crohn's disease can be considerable, especially given the cycle of repeat testing due to the low diagnostic yield of certain procedures and the inability of current diagnostic procedures to image the entire small bowel. WCE has a higher average diagnostic yield than comparative procedures due to imaging clarity and the ability to visualize the entire small bowel. Literature review found the average diagnostic yield of SBFT and colonoscopy for work-up of Crohn's disease to be 53.87%, whereas WCE had a diagnostic yield of 69.59%. A simple decision tree model comparing two arms--colonoscopy and SBFT, or WCE--estimates that WCE produces a cost savings of 291dollars for each case presenting for diagnostic

  2. Hypnosis before diagnostic or therapeutic medical procedures: a systematic review.

    PubMed

    Cheseaux, Nicole; de Saint Lager, Alix Juillet; Walder, Bernhard

    2014-01-01

    The aim of this systematic review was to estimate the efficiency of hypnosis prior to medical procedures. Different databases were analyzed to identify randomized controlled trials (RCTs) comparing hypnosis to control interventions. All RCTs had to report pain or anxiety. Eighteen RCTs with a total of 968 patients were included; study size was from 20 to 200 patients (14 RCTs ≤ 60 patients). Fourteen RCTs included 830 adults and 4 RCTs included 138 children. Twelve of 18 RCTs had major quality limitations related to unclear allocation concealments, provider's experience in hypnosis, patient's adherence to hypnotic procedures, and intention-to-treat design. This systematic review observed major methodological limitations in RCTs on hypnosis prior to medical procedures.

  3. Computer-Aided Performance Training for Diagnostic and Procedural Tasks.

    ERIC Educational Resources Information Center

    Rigney, Joseph W.; And Others

    Two computer programs for computer-assisted performance training were developed to give the students the opportunity for concentrated practice of troubleshooting and procedural tasks in naval electronics. In contrast to the usual approach taken in computer-assisted instruction (CAI), these programs simulate essential aspects of devices and tasks…

  4. Managing Urban School System Resources: New Procedures, Addition Actors.

    ERIC Educational Resources Information Center

    Hentschke, Guilbert C.

    In recent years urban school systems have had to face unusually severe economic constraints. In the process of adjusting to these constraints, urban systems will likely seek new ways to reallocate existing resources and will undertake more cooperative ventures with other organizational entities to gain access to additional resources. Four…

  5. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  6. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    SciTech Connect

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr. )

    1991-03-13

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk (RR), 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays.

  7. Diagnostic and therapeutic-restorative procedures for masticatory dysfunctions

    PubMed Central

    Freesmeyer, Wolfgang B.; Fussnegger, M. R.; Ahlers, M. O.

    2005-01-01

    Temporomandibular disorders (TMD) or craniomandibular disorders, respectively, involve diseases of the teeth and periodontia as well as the masticatory muscles, temporomandibular joints and associated structures. It has been shown in recent years that psychological, social and general medical influences are of enormous importance in the etiology of TMD in addition to anatomical, physiological, parafunctional and other biological causes. This signifies that therapists confronted with TMD should already include at an early stage other specialists such as pain therapists, neurologists, ENT physicians, psychotherapists and physiotherapists. Patients need to be referred to dentists specializing in TMD when ENT examinations yield no pathological findings. The treatment of TMD is subdivided into the following steps that are always related to underlying diagnoses: informing patients, self-observation, relaxation therapy, behavioral therapy, physiotherapy, drug therapy, therapeutic local anesthesia, splint therapy, and, if necessary, prosthetic and/or orthodontic therapy to restore a stable occlusion. PMID:22073067

  8. [Differential diagnostic procedure in sonographically detected fetal cystic hygroma].

    PubMed

    Holzgreve, W

    1985-01-01

    A series of 5 consecutive cases of fetal cystic hygroma diagnosed prenatally in the second trimester by sonography within a year in an ultrasound screening program is presented. 3 fetuses had a 45,X karyotype, one fetus had a 47,XY,+21 chromosome constitution and in one case no cytogenetic abnormality could be found. Because there was a cleft palate present in this latter female fetus, it is possible that this was a case of the recently described malformation syndrome. 3 of the pregnancies with fetal cystic hygroma ended in spontaneous abortion, in the other 2 cases the parents decided after careful genetic counseling to have an elective termination of pregnancy. Although Turner syndrome is the most frequent finding in cases of nuchal hygroma detected in utero by ultrasound, careful sonographic and cytogenetic studies as well as a detailed family history have to be obtained to delineate the cause of the malformation. On autopsy in all 3 cases with 45,X karyotype there were streak gonads, in 2 cases an additional hypoplasia of the aortic arch was found. Amniotic fluid alpha-fetoprotein and acetylcholinesterase determinations did not prove to add any significant information to the ultrasound evaluation of fetal cystic hygroma.

  9. 21 CFR 14.145 - Procedures of a color additive advisory committee.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Procedures of a color additive advisory committee. 14.145 Section 14.145 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PUBLIC HEARING BEFORE A PUBLIC ADVISORY COMMITTEE Color Additive Advisory Committees § 14.145 Procedures of a color additive...

  10. Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study

    PubMed Central

    Ihn, Yon Kwon; Byun, Jun Soo; Suh, Sang Hyun; Won, Yoo Dong; Lee, Deok Hee; Kim, Byung Moon; Kim, Young Soo; Jeon, Pyong; Ryu, Chang-Woo; Suh, Sang-il; Choi, Dae Seob; Choi, See Sung; Choi, Jin Wook; Chang, Hyuk Won; Lee, Jae-Wook; Kim, Sang Heum; Lee, Young Jun; Shin, Shang Hun; Lim, Soo Mee; Yoon, Woong; Jeong, Hae Woong; Han, Moon Hee

    2016-01-01

    Purpose To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). Materials and Methods We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. Results Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm2, 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm2 for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm2 for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. Conclusion Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. PMID:27621943

  11. Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study

    PubMed Central

    Ihn, Yon Kwon; Byun, Jun Soo; Suh, Sang Hyun; Won, Yoo Dong; Lee, Deok Hee; Kim, Byung Moon; Kim, Young Soo; Jeon, Pyong; Ryu, Chang-Woo; Suh, Sang-il; Choi, Dae Seob; Choi, See Sung; Choi, Jin Wook; Chang, Hyuk Won; Lee, Jae-Wook; Kim, Sang Heum; Lee, Young Jun; Shin, Shang Hun; Lim, Soo Mee; Yoon, Woong; Jeong, Hae Woong; Han, Moon Hee

    2016-01-01

    Purpose To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). Materials and Methods We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. Results Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm2, 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm2 for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm2 for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. Conclusion Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures.

  12. Additive manufacture (3d printing) of plasma diagnostic components and assemblies for fusion experiments

    NASA Astrophysics Data System (ADS)

    Sieck, Paul; Woodruff, Simon; Stuber, James; Romero-Talamas, Carlos; Rivera, William; You, Setthivoine; Card, Alexander

    2015-11-01

    Additive manufacturing (or 3D printing) is now becoming sufficiently accurate with a large range of materials for use in printing sensors needed universally in fusion energy research. Decreasing production cost and significantly lowering design time of energy subsystems would realize significant cost reduction for standard diagnostics commonly obtained through research grants. There is now a well-established set of plasma diagnostics, but these expensive since they are often highly complex and require customization, sometimes pace the project. Additive manufacturing (3D printing) is developing rapidly, including open source designs. Basic components can be printed for (in some cases) less than 1/100th costs of conventional manufacturing. We have examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques to determine costs of components and labor costs associated with getting the diagnostic to work as intended. With that information in hand, we set about optimizing the design to exploit the benefits of AM. Work performed under DOE Contract DE-SC0011858.

  13. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Payment for hospital outpatient radiology services... SKILLED NURSING FACILITIES Specific Categories of Costs § 413.122 Payment for hospital outpatient... services and other diagnostic procedures performed by a hospital on an outpatient basis. (2) For...

  14. 28 CFR 34.4 - Additional competitive application requirements and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AND PEER REVIEW PROCEDURES Competition § 34.4 Additional competitive application requirements and... particular part C program area covered by the announced program (peer review). Supplementary application review procedures, in addition to internal review and peer review, may be used for each competitive...

  15. 28 CFR 34.4 - Additional competitive application requirements and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AND PEER REVIEW PROCEDURES Competition § 34.4 Additional competitive application requirements and... particular part C program area covered by the announced program (peer review). Supplementary application review procedures, in addition to internal review and peer review, may be used for each competitive...

  16. 28 CFR 34.4 - Additional competitive application requirements and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND PEER REVIEW PROCEDURES Competition § 34.4 Additional competitive application requirements and... particular part C program area covered by the announced program (peer review). Supplementary application review procedures, in addition to internal review and peer review, may be used for each competitive...

  17. 28 CFR 34.4 - Additional competitive application requirements and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AND PEER REVIEW PROCEDURES Competition § 34.4 Additional competitive application requirements and... particular part C program area covered by the announced program (peer review). Supplementary application review procedures, in addition to internal review and peer review, may be used for each competitive...

  18. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory...

  19. An Overview of Models of Speaking Performance and Its Implications for the Development of Procedural Framework for Diagnostic Speaking Tests

    ERIC Educational Resources Information Center

    Zhao, Zhongbao

    2013-01-01

    This paper aims at developing a procedural framework for the development and validation of diagnostic speaking tests. The researcher reviews the current available models of speaking performance, analyzes the distinctive features and then points out the implications for the development of a procedural framework for diagnostic speaking tests. On…

  20. The Impact of Procedural Sedation on Diagnostic Errors in Pediatric Echocardiography

    PubMed Central

    Stern, Kenan W.D.; Gauvreau, Kimberlee; Geva, Tal; Benavidez, Oscar J.

    2014-01-01

    Background Infants and young children frequently have difficulty remaining still for an echocardiogram, potentially leading to poor study quality, increasing the likelihood of diagnostic errors. Sedation is believed to improve echocardiography quality; however, its effectiveness has not been demonstrated. We hypothesized that sedation would improve study quality and reduce diagnostic errors. Methods We examined outpatient echocardiograms in children ≤ 36 months from January 2008 – June 2009. We collected variables related to image quality, report completeness and sedation use. Diagnostic errors were identified and categorized. Multivariable analysis identified the odds ratio (OR) and 95% confidence interval (CI) for risk factors for potentially preventable diagnostic errors and the impact of sedation on these errors. Results Among 2,003 echocardiograms, sedation was used in 498 (25%). The overall diagnostic error rate was 6.5%. Most errors (66%) were potentially preventable. Multivariable analysis identified the following risk factors for potentially preventable errors: pre-cardiac procedure (OR 2.19, 95% CI 1.05 to 4.59, P=0.04); moderate anatomic complexity (OR 3.91, 95% CI 2.25 to 6.81, P<0.001); and high anatomic complexity (OR 8.36; 95% CI 3.57 to 19.6, P<0.001). Sedation was independently associated with lower odds for potentially preventable diagnostic error (OR 0.47, 95% CI 0.27 to 0.80, P=0.006). Echocardiograms with sedation had fewer image quality concerns (22% vs. 60%) and fewer incomplete reports (3% vs. 20%) (P<0.001). Conclusions Most echocardiographic diagnostic errors among infants and young children are potentially preventable. Sedation is associated with a lower likelihood of these diagnostic errors, fewer imaging quality concerns, and fewer incomplete reports. PMID:24930122

  1. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Policies and procedures for determining the credit hours, as defined in 34 CFR 600.2, that the institution... 34 Education 3 2012-07-01 2012-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of...

  2. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Policies and procedures for determining the credit hours, as defined in 34 CFR 600.2, that the institution... 34 Education 3 2014-07-01 2014-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of...

  3. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Policies and procedures for determining the credit hours, as defined in 34 CFR 600.2, that the institution... 34 Education 3 2013-07-01 2013-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of...

  4. Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center

    PubMed Central

    Chun, Chang Woo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong-Sam

    2014-01-01

    Objective To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. Materials and Methods We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Results Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm2, and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm2, and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm2, and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm2. On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). Conclusion Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level. PMID:25469098

  5. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  6. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  7. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  8. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  9. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  10. 78 FR 50079 - National Environmental Policy Act: Implementing Procedures; Addition to Categorical Exclusions...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-16

    ... list under the Lacey Act. The addition of this categorical exclusion to the Department of the Interior... Office of the Secretary National Environmental Policy Act: Implementing Procedures; Addition to... proposed categorical exclusion under the National Environmental Policy Act (NEPA) for the U.S. Fish...

  11. 24 CFR 570.711 - State borrowers; additional requirements and application procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT BLOCK GRANTS Loan Guarantees § 570.711 State borrowers; additional requirements and application... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false State borrowers; additional requirements and application procedures. 570.711 Section 570.711 Housing and Urban Development...

  12. 21 CFR 14.145 - Procedures of a color additive advisory committee.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Procedures of a color additive advisory committee. 14.145 Section 14.145 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PUBLIC HEARING BEFORE A PUBLIC ADVISORY COMMITTEE Color Additive Advisory Committees §...

  13. Activity based costing of diagnostic procedures at a nuclear medicine center of a tertiary care hospital

    PubMed Central

    Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha

    2014-01-01

    Context: Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. Aim: The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. Materials and Methods: A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. Results: The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. Conclusion: ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments. PMID:25400363

  14. Translation in different diagnostic procedures---traditional Chinese medicine and Western medicine.

    PubMed

    Hsiao, Chin-Fu; Tsou, Hsiao-Hui; Wu, Yuh-Jenn; Lin, Chien-Hsiung; Chang, Yeu-Jhy

    2008-12-01

    Recently, the modernization of traditional Chinese medicines (TCM) for treatment of patients with critical and/or life-threatening diseases has attracted much attention in the pharmaceutical industry. However, there exist essential differences in the evaluation of the efficacy and safety of a TCM as compared with a typical Western medicine (WM), even though they are for the same indication. Therefore, the modernization of a TCM should be based on a scientific evaluation of the safety and effectiveness of the TCM in terms of well-established quantitative criteria. We propose a study design to study the calibration and validation of the Chinese diagnostic procedure for evaluation of a TCM, with respect to a well-established clinical endpoint for evaluation of a WM. Statistical validation of such an instrument is essential to have an accurate and reliable clinical assessment of the performance of the TCM. Similar to the validation of a typical quality of life instrument, some validation performance characteristics such as validity, reliability, and ruggedness are considered. In this article, a design for validation of a standard quantitative instrument to be commonly employed for diagnosis of patient function/activity, performance, disease signs and symptoms, and disease status and severity based on Chinese diagnostic practice is proposed. Methods for statistical validation of the standard instrument are derived. More specifically, for validation of the TCM diagnostic instrument, we consider the following validation performance characteristics (parameters): validity (or accuracy), reliability (or precision), and ruggedness (interrater variability). A numerical example is given to illustrate the proposed methods for validation of the Chinese diagnostic procedure.

  15. The use of procedural knowledge in simple addition and subtraction problems.

    PubMed

    Fayol, Michel; Thevenot, Catherine

    2012-06-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second experiment replicates these results on addition and multiplication and, moreover, shows that the priming effect in addition is observed for all problems, including very small ones such as 4+3. In fact, the only problems that were not primed by the addition sign were tie problems, which confirms that they have a special status in memory. Taken together, these results suggest that abstract procedures are pre-activated by the addition and subtraction signs and that these procedures are consequently used by adults to solve the problems. No such procedures would be pre-activated for multiplication, which are then most probably solved by retrieval of the result from memory. Moreover, while obviously two different strategies were used by individuals in order to solve addition and multiplication, solution times were similar when the problems were presented in their whole. These results, which question most of the conclusions of the current literature, support Anderson's model (1982) and Baroody's assumptions (1983) on the existence of compacted procedures that could be as fast as retrievals. PMID:22405923

  16. Cognitive and emotional aspects of polygraph diagnostic procedures: a comment on Palmatier and Rovner (2015).

    PubMed

    Elaad, Eitan

    2015-01-01

    Palmatier and Rovner (2015) suggested that the Preliminary Process Theory (PPT) is a plausible theoretical account for explaining the rationale underlying two major polygraph tests, the Comparison Question Test (CQT) and the Concealed Information Test (CIT). To support their suggestion they claimed that both tests detect deception while relying on orienting responses. This approach is critically discussed. It was concluded that application of current scientific theories to polygraph diagnostic procedures should be done separately for the CIT and for the CQT. Finally, a call was extended for more research on unanswered questions in polygraph testing. PMID:25093905

  17. Cognitive and emotional aspects of polygraph diagnostic procedures: a comment on Palmatier and Rovner (2015).

    PubMed

    Elaad, Eitan

    2015-01-01

    Palmatier and Rovner (2015) suggested that the Preliminary Process Theory (PPT) is a plausible theoretical account for explaining the rationale underlying two major polygraph tests, the Comparison Question Test (CQT) and the Concealed Information Test (CIT). To support their suggestion they claimed that both tests detect deception while relying on orienting responses. This approach is critically discussed. It was concluded that application of current scientific theories to polygraph diagnostic procedures should be done separately for the CIT and for the CQT. Finally, a call was extended for more research on unanswered questions in polygraph testing.

  18. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    PubMed

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome. PMID:19330183

  19. Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey

    PubMed Central

    Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    Objective We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. Materials and Methods We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. Results The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Conclusion Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion. PMID:26576117

  20. The Australian experiment: the use of evidence based medicine for the reimbursement of surgical and diagnostic procedures (1998–2004)

    PubMed Central

    O'Malley, Sue P

    2006-01-01

    Background In 1998 a formal process using the criteria of safety, effectiveness and cost-effectiveness (evidence based medicine) on the introduction and use of new medical procedures was implemented in Australia. As part of this process an expert panel, the Medical Services Advisory Committee (MSAC) was set up. This paper examines the effectiveness of this process based on the original criteria, that is, evidence based medicine. Method The data for this analysis was sourced primarily from that made available in the public domain. The MSAC web site provided Minutes from MSAC meetings; Annual Reports; Assessment and Review reports; Progress status; and Archived material. Results The total number of applications submitted to the MSAC has been relatively low averaging approximately only fourteen per year. Additionally, the source of applications has quickly shifted to the medical devices, equipment and diagnostic industry as being the major source of applications. An overall average time for the processing of an application is eighteen months. Negative recommendations were in most cases based on insufficient clinical evidence rather than clinical evidence that clearly demonstrated a lack of clinical effectiveness. It was rare for a recommendation, either positive or negative, to be based on cost-effectiveness. Conclusion New medical procedures are often the result of a process of experimentation rather than formally conducted research. Affordability and the question of who should pay for the generation, collection and analysis of the clinical evidence is perhaps the most difficult to answer. This is especially the case where the new procedure is the result of a process of experimentation with an old procedure. A cost-effective way needs to be found to collect acceptable levels of evidence proving the clinical effectiveness of these new procedures, otherwise the formal processes of evaluation such as that used by the Australian MSAC since 1998 will continue to run the

  1. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    SciTech Connect

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-11-30

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added.

  2. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  3. Causing Students to Choose More Language Arts Work: Enhancing the Validity of the Additive Interspersal Procedure

    ERIC Educational Resources Information Center

    Meadows, Sadonya F.; Skinner, Christopher H.

    2005-01-01

    Research on the additive interspersal procedure was extended by exposing seventh-grade students to curricula-based (e.g., educationally valid) language arts assignments. In Experiment I, each student was given a control language arts assignment containing 20 discrete target items and an experimental assignment containing 24 equivalent target…

  4. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 3 2011-07-01 2011-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION THE SECRETARY'S RECOGNITION OF ACCREDITING AGENCIES The Criteria...

  5. Determinants of contrast in the signal-key procedure: Evidence against additivity theory.

    PubMed

    Williams, B A; Heyneman, N

    1981-03-01

    Two experiments are reported that challenge the interpretation of previous results with the signal-key procedure, in which the discriminative stimuli are located on a response key different from the key associated with the operant response requirement. Experiment 1 replicated the procedure of Keller (1974), and found that contrast effects on the operant key occurred reliably for only one of four subjects. High rates to the signal key initially occurred for only one subject, but modifications of the procedure produced substantial rates to the signal key for all subjects. In all cases, however, signal-key behavior was greatly reduced by the addition of a changeover delay which prevented reinforcement within 2 seconds of the last peck to the signal key, suggesting that signal-key pecking was maintained primarily by adventitious reinforcement. Experiment 2 modified the signal-key procedure by using three response keys, so that the discriminative stimuli on the signal key controlled different responses during all phases of training. With this modification, reliable contrast effects on the operant key occurred for all subjects, suggesting that the failure to find contrast in previous studies has been due to the confounding of changes in the discrimination requirements with changes in relative rate of reinforcement. The results challenge the additivity theory of contrast, and suggest that "elicited" behavior plays a minor role, if any, in the determination of contrast effects in multiple schedules.

  6. Proposed preliminary diagnostic reference levels for three common interventional cardiology procedures in Ireland.

    PubMed

    D'Helft, C; McGee, A; Rainford, L; McFadden, S; Winder, J; Hughes, C; Brennan, P C

    2008-01-01

    This study has gathered data across Ireland to determine the range of radiation doses received during interventional cardiology (IC) investigations. Radiation doses for three common types of IC examinations where investigated: coronary angiography (CA), percutaneous coronary intervention (PCI) and pacemaker insertions (PPI). A total of 22 cardiac imaging suites participated in the study. Radiation dose was monitored for 1804 adult patients using dose area product (DAP) meters. Individual patient DAP values ranged from 136-23,101 cGy cm2, 475-41,038 cGy cm2 and 45-17,192 cGy cm2 for CA, PCI and PPI respectively, with third quartile values of 4654 cGy cm2, 10,650 cGy cm2 and 1686 cGy cm2. The importance of optimising radiation dose, while not compromising diagnostic efficacy is clear. Although setting reference levels for these complex procedures has some difficulties, it is important that some guideline values are available as a benchmark to guide the operators during these potentially high dose procedures. The third quartile values as described by this paper may offer such guidance.

  7. Toxicity Minimized Cryoprotectant Addition and Removal Procedures for Adherent Endothelial Cells

    PubMed Central

    Davidson, Allyson Fry; Glasscock, Cameron; McClanahan, Danielle R.; Benson, James D.; Higgins, Adam Z.

    2015-01-01

    Ice-free cryopreservation, known as vitrification, is an appealing approach for banking of adherent cells and tissues because it prevents dissociation and morphological damage that may result from ice crystal formation. However, current vitrification methods are often limited by the cytotoxicity of the concentrated cryoprotective agent (CPA) solutions that are required to suppress ice formation. Recently, we described a mathematical strategy for identifying minimally toxic CPA equilibration procedures based on the minimization of a toxicity cost function. Here we provide direct experimental support for the feasibility of these methods when applied to adherent endothelial cells. We first developed a concentration- and temperature-dependent toxicity cost function by exposing the cells to a range of glycerol concentrations at 21°C and 37°C, and fitting the resulting viability data to a first order cell death model. This cost function was then numerically minimized in our state constrained optimization routine to determine addition and removal procedures for 17 molal (mol/kg water) glycerol solutions. Using these predicted optimal procedures, we obtained 81% recovery after exposure to vitrification solutions, as well as successful vitrification with the relatively slow cooling and warming rates of 50°C/min and 130°C/min. In comparison, conventional multistep CPA equilibration procedures resulted in much lower cell yields of about 10%. Our results demonstrate the potential for rational design of minimally toxic vitrification procedures and pave the way for extension of our optimization approach to other adherent cell types as well as more complex systems such as tissues and organs. PMID:26605546

  8. Can diagnostic and procedural skills required to practice cardiology as a specialist be mastered in 3 years?

    PubMed

    Yu, Eric H C; Nair, Parvathy; Sibbald, Matthew G; Lee, Douglas S; Dorian, Paul

    2015-01-01

    Cognitive and procedural skills required of cardiologists have increased in the past 10 years. What is unknown is whether residents consistently meet recommended volumes during training and what their own subjective assessments of their competency are after training. The purpose of this study was to (1) determine whether current training provides residents with opportunities to develop skills to function independently and (2) identify whether residents perceive gaps in their skills. We surveyed current and recent graduates of adult cardiology programs in Canada. One hundred ten responses from 425 surveys were received. Procedural and diagnostic test interpretation volumes were recorded, as were the optimum number the respondents believed were important to complete to function independently. These volumes were compared with the 2008 American College of Cardiology Core Cardiology Training Symposium (COCATS 3) and the Canadian Cardiovascular Society (CCS) recommendations for training. The proportion of residents meeting recommended volumes for diagnostic test interpretation ranged from 7% (Holter monitors) to 91% (echocardiograms). For procedures, the range was from 71% (echocardiography) to 100% (cardioversion). The ratio of residents' perceived minimum numbers believed to be required for proficiency for diagnostic test interpretation to those recommended ranged from 14% (electrocardiograms) to 116% (echocardiograms), and for procedures, the ratio was 66% (temporary pacemaker placement) to 116% (echocardiography). Recent graduates' perception of minimum required numbers to achieve competency is underestimated compared with COCATS 3 and CCS recommendations. Few graduates achieved the recommended volume targets suggested for diagnostic test interpretation.

  9. Developmental Dyslexia: A Diagnostic Screening Procedure on Three Characteristic Patterns of Reading and Spelling. A Preliminary Report.

    ERIC Educational Resources Information Center

    Boder, Elena

    A diagnostic screening procedure for developmental dyslexia which analyzes how a child reads and writes rather than at what level, is outlined. Briefly, the test entails a presentation of a word list at each reading level to determine the child's sight vocabulary and his ability to employ word-attack skills. Following the administration of the…

  10. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  11. A comparative analysis of British and Taiwanese students' conceptual and procedural knowledge of fraction addition

    NASA Astrophysics Data System (ADS)

    Li, Hui-Chuan

    2014-10-01

    This study examines students' procedural and conceptual achievement in fraction addition in England and Taiwan. A total of 1209 participants (561 British students and 648 Taiwanese students) at ages 12 and 13 were recruited from England and Taiwan to take part in the study. A quantitative design by means of a self-designed written test is adopted as central to the methodological considerations. The test has two major parts: the concept part and the skill part. The former is concerned with students' conceptual knowledge of fraction addition and the latter is interested in students' procedural competence when adding fractions. There were statistically significant differences both in concept and skill parts between the British and Taiwanese groups with the latter having a higher score. The analysis of the students' responses to the skill section indicates that the superiority of Taiwanese students' procedural achievements over those of their British peers is because most of the former are able to apply algorithms to adding fractions far more successfully than the latter. Earlier, Hart [1] reported that around 30% of the British students in their study used an erroneous strategy (adding tops and bottoms, for example, 2/3 + 1/7 = 3/10) while adding fractions. This study also finds that nearly the same percentage of the British group remained using this erroneous strategy to add fractions as Hart found in 1981. The study also provides evidence to show that students' understanding of fractions is confused and incomplete, even those who are successfully able to perform operations. More research is needed to be done to help students make sense of the operations and eventually attain computational competence with meaningful grounding in the domain of fractions.

  12. Indiana Reading Diagnostic Assessment: Resource & Intervention Guide, Kindergarten. Additional Activities and Assessments

    ERIC Educational Resources Information Center

    Indiana Department of Education, 2006

    2006-01-01

    The materials included in this manual are organized according to the Indiana's Kindergarten Academic Standards for English/Language Arts. In each section teachers will find: (1) Indiana's Kindergarten Academic Standards for English/Language Arts Assessments: Black Line Masters of diagnostic/practice pages for skill areas, checklists, and rubrics;…

  13. A survey of close contact regimes between patients undergoing diagnostic radioisotope procedures and children.

    PubMed

    Greaves, C D; Tindale, W B; Flynn, P J

    1996-07-01

    When following diagnostic radioisotope procedures, UK legislation requires that we advise patients to avoid close contact with children [1, 2]. How does this advice affect the average nuclear medicine patient? Over a 4 month period, 90 patients in contact with children were asked about their home circumstances, how they coped with avoidance of close contact and the problems caused. On average, the patients were in contact with two children with a mean age of 7 years. Thirty-nine per cent of patients spent < 5 h per day and 30% between 5 and 10 h per day in close contact. However, 13% spent 20-24 h in close contact with children. For most patients (55%), it is easy to avoid close contact, but 25% found it difficult or very difficult. The average in-patient received one visit a day from children of 0.5-1 h duration and 65% of children sat on the patient's bed. Restriction of visits was a problem for 14% of patients. Initially, over one-third of the out-patients felt a medium level of anxiety or higher regarding close contact with children. Given more detailed written information and the opportunity to discuss any queries with a member of staff (70% wished to do so), the proportion fell to less than one-tenth. We found it important to question patients carefully, because home circumstances and levels of close contact cannot be deduced from the age of the child or the relationship between the child and the patient. PMID:8843113

  14. Evaluation of diagnostic procedures for subclinical mastitis in meat-producing sheep.

    PubMed

    Clements, Archie C A; Taylor, David J; Fitzpatrick, Julie L

    2003-05-01

    Samples of foremilk were collected from 261 clinically normal glands of 150 ewes, and tested using the California mastitis test (CMT). Further samples were collected from 195 of these glands for determination of automated somatic cell counts (SCC), and from 60 of these glands for bacteriological assessment. The sensitivity and specificity of CMT for detecting samples with SCC above different threshold levels and for CMT and SCC in determining bacteriological status were evaluated using two-graph receiver operating characteristics (TG-ROC). Milk samples were obtained subsequently from ten CMT positive, and five CMT negative first- and second-lactation ewes. Samples were cultured using a variety of media, incubation temperatures and atmospheric conditions, immediately after collection, and 1 week after storage at 4 degrees C and -21 degrees C. Results suggested that CMT is best used as a diagnostic test for ovine subclinical mastitis (SCM) with a cut-off of 3 (distinct gel formation), and that automated SCC thresholds of > 1200 x 10(3) cells/ml are appropriate, especially where low prevalences are expected (e.g. < 5%). Additionally, this study showed that routine bacteriological methods were appropriate for isolation of most species of pathogen responsible for ovine SCM, but storage of samples prior to culture, either at 4 degrees C or -21 degrees C, was detrimental to the isolation of several of these organisms.

  15. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  16. Impact of contacting study authors to obtain additional data for systematic reviews: diagnostic accuracy studies for hepatic fibrosis

    PubMed Central

    2014-01-01

    Background Seventeen of 172 included studies in a recent systematic review of blood tests for hepatic fibrosis or cirrhosis reported diagnostic accuracy results discordant from 2 × 2 tables, and 60 studies reported inadequate data to construct 2 × 2 tables. This study explores the yield of contacting authors of diagnostic accuracy studies and impact on the systematic review findings. Methods Sixty-six corresponding authors were sent letters requesting additional information or clarification of data from 77 studies. Data received from the authors were synthesized with data included in the previous review, and diagnostic accuracy sensitivities, specificities, and positive and likelihood ratios were recalculated. Results Of the 66 authors, 68% were successfully contacted and 42% provided additional data for 29 out of 77 studies (38%). All authors who provided data at all did so by the third emailed request (ten authors provided data after one request). Authors of more recent studies were more likely to be located and provide data compared to authors of older studies. The effects of requests for additional data on the conclusions regarding the utility of blood tests to identify patients with clinically significant fibrosis or cirrhosis were generally small for ten out of 12 tests. Additional data resulted in reclassification (using median likelihood ratio estimates) from less useful to moderately useful or vice versa for the remaining two blood tests and enabled the calculation of an estimate for a third blood test for which previously the data had been insufficient to do so. We did not identify a clear pattern for the directional impact of additional data on estimates of diagnostic accuracy. Conclusions We successfully contacted and received results from 42% of authors who provided data for 38% of included studies. Contacting authors of studies evaluating the diagnostic accuracy of serum biomarkers for hepatic fibrosis and cirrhosis in hepatitis C patients

  17. Influence of crushing and additive irradiation procedures on EPR dosimetry of tooth enamel

    SciTech Connect

    Shalom, S.V.; Chumak, V.V.; Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1996-01-01

    The effect of the crushing and additive dose procedures used in EPR dosimetry of enamel was studied on the signals with g-factors of 2. 0045 and g, = 2.0018, g. = 1.9975. Eight fractions, ranging in size from <75 micrometers to 2 mm, were prepared from one tooth. Two cases were investigated: crushing of a non-irradiated sample and of a sample previously irradiated (6 Gy from `Co gamma ray source). In the non-irradiated study, the intensity of the native signal at 2.0045 in by circa 1.75 times as the grain size decreased from maximum to minimum. A small in radiation sensitivity (< 8%) was also observed with decreasing grain size. In the irradiated samples, crushing resulted in slight variations of reconstructed doses from expected values, but the worst possible case (grain sizes < 75 micron) showed that additional errors were less than 10%. The radiation sensitivity of enamel measured immediately after exposure is underestimated. It increases by about 15% in the first month. Based on the decomposition of the observed spectra, a new interpretation of transient signals 1108 is proposed which explains the above phenomena. Recommendations about how to use this interpretation in retrospective EPR dosimetry are given.

  18. 13 CFR 302.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... policies and procedures. 302.6 Section 302.6 Business Credit and Assistance ECONOMIC DEVELOPMENT... requirements; Federal policies and procedures. Recipients are subject to all Federal laws and to Federal, Department and EDA policies, regulations and procedures applicable to Federal financial assistance...

  19. Antibodies to phosphatidylserine/prothrombin complex as an additional diagnostic marker of APS?

    PubMed

    Žigon, P; Čučnik, S; Ambrožič, A; Sodin Šemrl, S; Kveder, T; Božič, B

    2012-06-01

    Antiprothrombin antibodies can be measured by ELISA using either a prothrombin/phosphatidylserine complex (aPS/PT) or prothrombin alone (aPT) as antigen. We aimed to compare the clinical features of autoimmune patients with avidity of aPS/PT and determine the diagnostic efficiency of aPS/PT and aPT for assessing antiphospholipid syndrome (APS). aPS/PT were of low (n = 9), heterogeneous (n = 31) and high (n = 8) avidity out of 48 cases. None of the samples with low avidity were positive in aPT ELISA. Among patients with heterogeneous or high avidity aPS/PT, there was a significantly greater number of patients with APS as compared to patients with low avidity (38/39 vs. 7/9; p < 0.05). No SLE patients had high avidity antiprothrombin antibodies.

  20. Use of balloon flotation pacing catheters for prophylactic temporary pacing during diagnostic and therapeutic catheterization procedures.

    PubMed

    Harvey, J R; Wyman, R M; McKay, R G; Baim, D S

    1988-11-01

    The use of prophylactic temporary pacemakers during diagnostic catheterization, coronary angioplasty and percutaneous balloon valvuloplasty was investigated retrospectively over an 18-month period. Balloon flotation temporary pacemaker leads were placed in 193 (12%) of 1,609 patients undergoing diagnostic catheterization, 641 (65%) of 993 patients undergoing coronary angioplasty and 199 (100%) of 199 patients undergoing aortic or mitral valvuloplasty. There were no perforations or significant arrhythmic complications related to pacemaker placement in these 1,033 cases, and pacing was initiated promptly when required by withdrawal of the catheter tip into the right ventricle. Significant bradycardia or new conduction defects developed in 17 patients (1%) during diagnostic catheterization, 10 patients (1%) during angioplasty and 20 patients (10%) during valvuloplasty, but were severe enough to require initiation of temporary pacing in only 1 (0.06%), 4 (0.4%) and 5 (2.5%) patients, respectively. No patient undergoing diagnostic catheterization or angioplasty (but 5 patients undergoing valvuloplasty) required immediate pacing support to treat a life-threatening bradycardia. The total cost of prophylactic pacemakers was $103,300, with a cost per actual use of $19,300 for diagnostic cases, $16,025 for angioplasty and $3,980 for balloon valvuloplasty. These data suggest that prophylactic temporary pacing is not indicated during either diagnostic catheterization or coronary angioplasty, but should be used routinely during balloon valvuloplasty.

  1. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... REIMBURSEMENT; PAYMENT FOR END-STAGE RENAL DISEASE SERVICES; OPTIONAL PROSPECTIVELY DETERMINED PAYMENT RATES FOR... medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  2. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... REIMBURSEMENT; PAYMENT FOR END-STAGE RENAL DISEASE SERVICES; OPTIONAL PROSPECTIVELY DETERMINED PAYMENT RATES FOR... medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  3. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... REIMBURSEMENT; PAYMENT FOR END-STAGE RENAL DISEASE SERVICES; OPTIONAL PROSPECTIVELY DETERMINED PAYMENT RATES FOR... medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  4. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... REIMBURSEMENT; PAYMENT FOR END-STAGE RENAL DISEASE SERVICES; OPTIONAL PROSPECTIVELY DETERMINED PAYMENT RATES FOR... medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  5. Anti-phosphatidylserine/prothrombin antibodies: an additional diagnostic marker for APS?

    PubMed

    Pregnolato, Francesca; Chighizola, Cecilia B; Encabo, Susan; Shums, Zakera; Norman, Gary L; Tripodi, Armando; Chantarangkul, Veena; Bertero, Tiziana; De Micheli, Valeria; Borghi, Maria Orietta; Meroni, Pier Luigi

    2013-07-01

    Among the diagnostic assays for anti-phospholipid syndrome (APS), lupus anticoagulant (LA) is the strongest predictor of thrombosis; however, it presents several limitations as interference with anticoagulant therapy and poor inter-laboratory agreement. Two-thirds of LA activity is apparently due to antibodies against prothrombin (PT), usually detectable by ELISA. Binding of PT to phosphatidylserine (PS) has been shown to enhance solid-phase anti-PT assay sensitivity. To determine the prevalence of antibodies against PS/PT (aPS/PT) in APS, we tested the semiquantitative QUANTA Lite(®) aPS/PT ELISA in a cohort of 80 APS patients. The prevalence of aPS/PT was 81.3%, rising to 87.6% when considering LA-positive subjects only. We observed a strong correlation between aPS/PT and LA (p = 0.006). To note, APS patients with thrombotic manifestations displayed significantly higher IgG aPS/PT titers compared to 20 aPL asymptomatic carriers (p = 0.012). To rule out a possible cross-reactivity of anti-β2 glycoprotein I antibodies (aβ2GPI) with PS/PT complex, we tested two monoclonal aβ2GPI antibodies and an affinity-purified (AP) polyclonal aβ2GPI IgG obtained from the serum of a patient reacting against both β2GPI and PS/PT. The two monoclonal antibodies did not show any reactivity against PS/PT complex, similarly the AP IgGs did not react toward PS/PT antigen while preserved their aβ2GPI activity. Our findings suggest that aPS/PT are a definite antibody population in APS. Moreover, the good correlation between aPS/PT ELISA and LA may support its use as a surrogate test for LA, particularly useful to overcome the technical limitations of the functional assay.

  6. Diagnostic procedures for Trend Monitoring System (TMS) communications. [coaxial cable bus system

    NASA Technical Reports Server (NTRS)

    Brown, J. S.; Lenker, M. D.

    1979-01-01

    A prototype coaxial cable bus communications sytem was developed to support the trend monitoring system (TMS). Troubleshooting procedures are described at the system level. The procedures can be used by repair personnel to isolate a fault in the TMS and to restore the system to operation by swapping out failed components.

  7. Measuring the Academic Skills of University Students: Evaluation of a Diagnostic Procedure

    ERIC Educational Resources Information Center

    Erling, Elizabeth J.; Richardson, John T. E.

    2010-01-01

    Measuring the Academic Skills of University Students is a procedure developed in the 1990s at the University of Sydney's Language Centre to identify students in need of academic writing development by assessing examples of their written work against five criteria. This paper reviews the literature relating to the development of the procedure with…

  8. Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures; Federal Guidance Report No. 14

    EPA Science Inventory

    Federal Guidance Report No. 14 provides federal facilities that use diagnostic and interventional x-ray equipment with updated recommendations for keeping doses as low as reasonably achievable without compromising the quality of patient care, This guidance is an update of Federal...

  9. Taking a Closer Look at Writing. Education 5-14, English Language Diagnostic Procedures.

    ERIC Educational Resources Information Center

    Hall, John; And Others

    Offering guidance on diagnostic and developmental techniques, this teacher's guide helps teachers to assess pupils' understanding and day-to-day progress in writing and to identify appropriate next steps to help pupils make progress. The teacher's guide examines the process of writing, offering guidance on classroom activities relating to…

  10. 13 CFR 108.1940 - Procedures for designation of additional Low-Income Geographic Areas

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... BUSINESS ADMINISTRATION NEW MARKETS VENTURE CAPITAL (âNMVCâ) PROGRAM Miscellaneous § 108.1940 Procedures... equivalent county division) has a pattern of unmet needs for investment capital. (3) As adequately...

  11. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests.

    PubMed

    Shan, Guogen; Amei, Amei; Young, Daniel

    2015-01-01

    Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003). However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  12. Number Words in Young Children's Conceptual and Procedural Knowledge of Addition, Subtraction and Inversion

    ERIC Educational Resources Information Center

    Canobi, Katherine H.; Bethune, Narelle E.

    2008-01-01

    Three studies addressed children's arithmetic. First, 50 3- to 5-year-olds judged physical demonstrations of addition, subtraction and inversion, with and without number words. Second, 20 3- to 4-year-olds made equivalence judgments of additions and subtractions. Third, 60 4- to 6-year-olds solved addition, subtraction and inversion problems that…

  13. 78 FR 57587 - Environmental Impact and Related Procedures-Programmatic Agreements and Additional Categorical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... (23 CFR 771.117(b); 23 CFR 771.118(b)). The Agencies first issued their NEPA Procedures in 1980 (45 FR... issued the 1987 revisions (52 FR 3264, Aug. 28, 1987) as part of a departmentwide effort to streamline... previously listed by an agency could be considered for CE status on a case-by-case basis'' (52 FR 32651,...

  14. 75 FR 2122 - Additional Guidance Regarding Application of Current Procedures for Testing Energy Consumption of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-14

    ...) standard HRF-1-1979 (HRF-1). See Appendix A1, section 2.2; 47 FR 34517 (Aug. 10, 1982). HRF-1 specifies... ensure the consistent application of DOE's current test procedure to refrigerator-freezers with French doors, bottom-mounted freezers, and through-the-door (TTD) ice service (French door TTD models)....

  15. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures

    PubMed Central

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P.

    2012-01-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging. PMID:22639482

  16. Work-related stress and bullying: gender differences and forensic medicine issues in the diagnostic procedure

    PubMed Central

    2011-01-01

    Background The attention of international agencies and scientific community on bullying and work-related stress is increasing. This study describes the gender differences found in victims of bullying and work-related stress in an Italian case series and analyzes the critical issues in the diagnostic workup. Methods Between 2001 and 2009 we examined 345 outpatients (148 males, 197 females; mean age: 41 ± 10.49) for suspected psychopathological work-related problems. Diagnosis of bullying was established using international criteria (ICD-10 and DSM-IV). Results After interdisciplinary diagnostic evaluation (Occupational Medicine Unit, Psychology and Psychiatry Service), the diagnosis of bullying was formulated in 35 subjects, 12 males and 23 females (2 cases of Post-Traumatic Stress Disorder and 33 of Adjustment Disorder). Fifty-four (20 males, 34 females) suffered from work-related anxiety, while work-unrelated Adjustment Disorder and other psychiatric disorders were diagnosed in 7 and 112 subjects, respectively. Women between 34 and 45 years showed a high prevalence (65%) of "mobbing syndrome" or other work-related stress disorders. Conclusions At work, women are more subject to harassment (for personal aspects related to emotional and relational factors) than men. The knowledge of the phenomenon is an essential requisite to contrast bullying; prevention can be carried out only through effective information and training of workers and employers, who have the legal obligation to preserve the integrity of the mental and physical status of their employees during work. PMID:22088163

  17. A World Allergy Organization International Survey on Diagnostic Procedures and Therapies in Drug Allergy/Hypersensitivity

    PubMed Central

    Mirakian, Rita; Castells, Mariana; Pichler, Werner; Romano, Antonino; Bonadonna, Patrizia; Diana, Deleanu; Kowalski, Marek; Yanez, Anahi; Lleonart, Ramon; Sanchez-Borges, Mario; Demoly, Pascal

    2011-01-01

    Objective To study the diagnostic and treatment modalities used in drug allergy/hypersensitivity among members of the World Allergy Organization (WAO). Methods A questionnaire comprising 39 questions was circulated electronically to member societies, associate member societies, and regional and affiliate organizations of WAO between June 29, 2009, and August 9, 2009. Results Eighty-two responses were received. Skin testing was used by 74.7%, with only 71.4% having access to penicillin skin test reagents. In vitro–specific IgE tests were used by 67.4%, and basophil activation test was used by 54.4%. Lymphocyte transformation tests were used by 36.8% and patch tests by 54.7%. Drug provocation tests were used by 68.4%, the most common indication being to exclude hypersensitivity where history/symptoms were not suggestive of drug hypersensitivity/allergy (76.9%). Rapid desensitization for chemotherapy, antibiotics, or biologic agents was used by 69.6%. Systemic corticosteroid was used in the treatment of Stevens–Johnson syndrome by 72.3%, and high-dose intravenous immunoglobulins in toxic epidermal necrolysis by 50.8%. Human leukocyte antigen screening before prescription of abacavir was used by 92.9% and before prescription of carbamazepine by 21.4%. Conclusions Results of this survey form a useful framework for developing educational and training needs and for improving access to drug allergy diagnostic and treatment modalities across WAO member societies. PMID:23268453

  18. [Quantitative measures for assessing the functional state of the human body during diagnostic procedure].

    PubMed

    Artemenko, M V

    2008-01-01

    Two approaches to calculation of the qualitative measures for assessing the functional state level of human body are considered. These approaches are based on image and fuzzy set recognition theories and are used to construct diagnostic decision rules. The first approach uses the data on deviation of detected parameters from those for healthy persons; the second approach analyzes the degree of deviation of detected parameters from the approximants characterizing the correlation differences between the parameters. A method for synthesis of decision rules and the results of blood count-based research for a number of diseases (hemophilia, thrombocytopathy, hypertension, arrhythmia, hepatic cirrhosis, trichophytia) are considered. An effect of a change in the functional link between the cholesterol content in blood and the relative rate of variation of AST and ALT enzymes in blood from direct proportional (healthy state) to inverse proportional (hepatic cirrhosis) is discussed. It is shown that analysis of correlation changes in detected parameters of the human body state during diagnostic process is more effective for application in decision support systems than the state space analysis.

  19. 13 CFR 108.1940 - Procedures for designation of additional Low-Income Geographic Areas

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) as LI Areas. (b) Criteria. SBA will consider one or more of the following factors in determining whether to designate a particular census tract (or equivalent county division) as an additional LI Area... designation of an additional LI Area, SBA will publish in the Federal Register a notice that it is...

  20. The Use of Procedural Knowledge in Simple Addition and Subtraction Problems

    ERIC Educational Resources Information Center

    Fayol, Michel; Thevenot, Catherine

    2012-01-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second…

  1. Malignancies in blood-forming organs following diagnostic and therapeutic procedures: a review.

    PubMed

    Hodgin, J D; Webster, P D

    1976-10-01

    Ionizing radiation used for diagnosis or therapy has been associated with an increased incidence of malignancies of blood-forming organs. The increased incidence of hematopoietic malignancies following exposure to ionizing radiation obtained in the course of occupation, diagnosis and therapy of disease, or as a weapon of war is documented. The natural occurrence and the induced progression to acute leukemia of polycythemia rubra vera, Hodgkin's disease, multiple myeloma, Di Guglielmo's disease, and reticuloendothelial malignancies are discussed. The status of transplantation and immunodeficiency states and their relationship to acute leukemia is reviewed. Finally, drugs, toxins, and the use of cytotoxic radiomimetic agents for nonmalignant purposes are shown to lead to the development of acute leukemia. Background information relevant to the proper use of future diagnostic and therapeutic modalities is provided.

  2. A Comparative Analysis of British and Taiwanese Students' Conceptual and Procedural Knowledge of Fraction Addition

    ERIC Educational Resources Information Center

    Li, Hui-Chuan

    2014-01-01

    This study examines students' procedural and conceptual achievement in fraction addition in England and Taiwan. A total of 1209 participants (561 British students and 648 Taiwanese students) at ages 12 and 13 were recruited from England and Taiwan to take part in the study. A quantitative design by means of a self-designed written test is…

  3. Evaluating Generalization of Addition-Fact Fluency Using the Taped-Problems Procedure in a Second-Grade Classroom

    ERIC Educational Resources Information Center

    Miller, Kelli C.; Skinner, Christopher H.; Gibby, Lana; Galyon, Charles E.; Meadows-Allen, Sadonya

    2011-01-01

    A multiple-baseline design across math-fact sets was used to evaluate the effects of a taped-problems intervention on students' performance with addition facts and their inverses in an intact, rural, second-grade classroom. Results suggested that the procedure was effective in improving fluency on math facts as well as their inverses. Across 3…

  4. The utility and validity of current diagnostic procedures for defining temporomandibular disorder patients.

    PubMed

    Clark, G T; Delcanho, R E; Goulet, J P

    1993-08-01

    This paper describes the evolution of different concepts of classifying and defining Temporomandibular Disorders (TMD) for both clinical and research settings. The literature is reviewed with respect to the utility and validity of the different questionnaire and examination procedures that have been used to assess TMD patients. The presented view is that many of these procedures have not been validated, that there is a lack of standardization in the use of the procedures themselves, and that an ideal method of classifying this broad group of patients into better-defined subgroups has not yet been developed. More standardized and better-defined research by trained and calibrated researchers is needed worldwide to elucidate these subgroups so that a better and widely agreed upon research classification system can be developed for widespread use. It also seems clear that as research requirements for defining TMD patient subgroups become more stringent over time, it may not be practical for the clinician to implement them on a day-to-day basis in his or her practice. As such, a practical utilitarian definition of the common subtype of TMD patients is also needed which parallels any research grouping, so that data from research are valuable and generalizable to the practicing clinician.

  5. Diagnostic procedures in tularaemia with special focus on molecular and immunological techniques.

    PubMed

    Splettstoesser, W D; Tomaso, H; Al Dahouk, S; Neubauer, H; Schuff-Werner, P

    2005-08-01

    Tularaemia is a severe bacterial zoonosis caused by the highly infectious agent Francisella tularensis. It is endemic in countries of the northern hemisphere ranging from North America to Europe, Asia and Japan. Very recently, Francisella-like strains causing disease in humans were described from tropical northern Australia. In the last decade, efforts have been made to develop sensitive and specific immunological and molecular techniques for the laboratory diagnosis of tularaemia and also for the definite identification of members of the species F. tularensis and its four subspecies. Screening for the keyword 'Francisella' a Medline search over the last decade was performed and articles describing diagnostic methods for tularaemia and its causative agent were selected. Besides classical microbiological techniques (cultivation, biochemical profiling, susceptibility testing) several new immunological and molecular approaches to identify F. tularensis have been introduced employing highly specific antibodies and various polymerase chain reaction (PCR)-based methods. Whereas direct antigen detection by enzyme-linked immunosorbent assay (ELISA) or immunofluorescence might allow early presumptive diagnosis of tularaemia, these methods--like all PCR techniques--still await further evaluation. Therefore, diagnosis of tularaemia still relies mainly on the demonstration of specific antibodies in the host. ELISA and immunoblot methods started to replace the standard tube or micro-agglutination assays. However, the diagnostic value of antibody detection in the very early clinical phase of tularaemia is limited. Francisella tularensis is regarded as a 'highest priority' biological agent (category 'A' according to the CDC, Atlanta, GA, USA), thus rapid and reliable diagnosis of tularaemia is required not only for a timely onset of therapy, the handling of outbreak investigations but also for the surveillance of endemic foci. Only very recently, evaluated test kits for

  6. Endoscopic infrared diaphanoscopy: its use and feasibility in diagnostic and treatment procedure for paranasal sinus diseases

    NASA Astrophysics Data System (ADS)

    Prapavat, Viravuth; Linnarz, Marietta; Hopf, Juergen U. G.; Beuthan, Juergen; Becker, Michael; Mueller, Gerhard J.; Scherer, Hans H.

    1994-07-01

    In the upper respiratory tract, a new endoscopic procedure with ultra-thin and miniature fiberoptics (290 micrometers - 2 mm) finds a wide range of application in the differential diagnosis and treatment of pathological changes, especially within the nasal cavities and the paranasal sinuses. In order to restore the normal condition of ventilation and drainage of the paranasal sinuses or to remove internal inflammation the given foramina or ducts are widened mechanically. In case of the ostium nasomaxillaris `anatomical landmarks' can be used for orientation. But in case of the ostium nasofrontalis ((theta) 1 - 3 mm) or revision surgery where the anatomical conditions are not definitely defined or totally changed, problems can occur due to a lack of orientation. Dangerous complications which can occur due to surgical disorientation are the injury of the optic nerve and the dura mater. This paper presents an endoscopic variation of the infrared idaphanoscopy (IRD), a band-limited cw transillumination method, which enables localization of the foramina or ducts during the endoscopic procedure resulting in a reduction in the risk of disorientation.

  7. [The syndrome of increased upper airways resistance: What are the clinical features and diagnostic procedures?].

    PubMed

    M'saad, S; Yangui, I; Feki, W; Abid, N; Bahloul, N; Marouen, F; Chakroun, A; Kammoun, S

    2015-12-01

    The upper airway resistance syndrome "UARS" is a poorly defined entity, often described as a moderate variant of the obstructive sleep apnea syndrome. It is associated with respiratory effort-related arousal, absence of obstructive sleep apnea, and absence of significant desaturation. It is a relatively common condition that predominantly affects non-obese young adults, with no predominance in either sex. The degree of upper airway collapsibility during sleep of patients with UARS is intermediate between that of normal subjects and that of patients with mild-to-moderate sleep apnea syndrome. Craniofacial and palatal abnormalities are often noted. Patients frequently complain of a functional somatic syndrome, especially daytime sleepiness and chronic fatigue. Polysomnography with esophageal pressure measurements remains the gold standard diagnostic test. The absence of any neurological abnormality gives UARS a good prognosis and it is potentially reversible if treated early. However, some studies suggest that untreated UARS has an increased risk of arterial hypertension. It can also evolve into obstructive sleep apnea. PMID:26525135

  8. 40 CFR 86.1734-99 - Alternative procedure for notification of additions and changes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program... the Administrator within 10 working days of making an addition of a vehicle to a certified engine family or a change in a vehicle previously covered by certification. The manufacturer shall also...

  9. 40 CFR 86.1734-99 - Alternative procedure for notification of additions and changes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program... the Administrator within 10 working days of making an addition of a vehicle to a certified engine family or a change in a vehicle previously covered by certification. The manufacturer shall also...

  10. 40 CFR 86.1734-99 - Alternative procedure for notification of additions and changes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program... the Administrator within 10 working days of making an addition of a vehicle to a certified engine family or a change in a vehicle previously covered by certification. The manufacturer shall also...

  11. Appendix to the Brophy-Good Dyadic Interaction Coding Manual. Additional Coding Categories and Procedures.

    ERIC Educational Resources Information Center

    Brophy, Jere E.; Good Thomas L.

    This paper contains optional modifications and additions to the Brophy-Good Dyadic Interaction Coding Manual (ED 042 688). Included are 1) suggestions for changes in the way level-of-question is coded; 2) modifications of the child's answer categories for simplification or expansion; 3) new distinctions for coding the teacher's feedback following…

  12. Fast automated counting procedures in addition problem solving: When are they used and why are they mistaken for retrieval?

    PubMed

    Uittenhove, Kim; Thevenot, Catherine; Barrouillet, Pierre

    2016-01-01

    Contrary to a widespread assumption, a recent study suggested that adults do not solve very small additions by directly retrieving their answer from memory, but rely instead on highly automated and fast counting procedures (Barrouillet & Thevenot, 2013). The aim of the present study was to test the hypothesis that these automated compiled procedures are restricted to small quantities that do not exceed the size of the focus of attention (i.e., 4 elements). For this purpose, we analyzed the response times of ninety adult participants when solving the 81 additions with operands from 1 to 9. Even when focusing on small problems (i.e. with sums ⩽10) reported by participants as being solved by direct retrieval, chronometric analyses revealed a strong size effect. Response times increased linearly with the magnitude of the operands testifying for the involvement of a sequential multistep procedure. However, this size effect was restricted to the problems involving operands from 1 to 4, whereas the pattern of response times for other small problems was compatible with a retrieval hypothesis. These findings suggest that very fast responses routinely interpreted as reflecting direct retrieval of the answer from memory actually subsume compiled automated procedures that are faster than retrieval and deliver their answer while the subject remains unaware of their process, mistaking them for direct retrieval from long-term memory.

  13. Frequency of use of diagnostic and manual therapeutic procedures of the spine currently taught at the Canadian Memorial Chiropractic College: A preliminary survey of Ontario chiropractors. Part 2 – procedure usage rates

    PubMed Central

    Gleberzon, Brian; Stuber, Kent

    2013-01-01

    Objective: The purpose of this study was to determine which diagnostic and therapeutic procedures of the spine are most commonly utilized by chiropractors practicing in Ontario, based on a list of currently taught procedures at CMCC. In Part 1 of this study (published previously), the demographics and practice patterns of the respondents were presented. Part 2 of this study (presented here) reports on the utilization rates of spinal diagnostic and therapeutic procedures by the respondents. Methods: The study consisted of a paper-based survey that was sent to 500 randomly selected Ontario chiropractors who responded confidentially. Survey questions inquired into demographic and practice style characteristics as well as the frequency with which spinal diagnostic and therapeutic procedures were performed. Results: There were 108 respondents to the survey, giving a response rate of 22.4%. Frequency of use of diagnostic procedures fell into three broad categories: (i) those tests that are almost always performed, (ii) those tests that are almost always performed by two-thirds to one-half of patients, and (iii) those tests that are virtually never used. By comparison, respondents utilized the same therapeutic procedures for patients care less consistently. Conclusions: Despite a low response rate, respondents reported mostly relying on static and motion palpation, joint play, neurological tests, and ranges of motion when assessing their patients. Due to a low response rate, the results of this study may not be generalizable to all Ontario chiropractors. PMID:23754862

  14. 36 CFR 51.12 - Are there any other additional procedures that I must follow to apply for a concession contract?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Are there any other additional procedures that I must follow to apply for a concession contract? 51.12 Section 51.12 Parks... Solicitation, Selection and Award Procedures § 51.12 Are there any other additional procedures that I...

  15. National decline in invasive prenatal diagnostic procedures in association with uptake of combined first trimester and cell-free DNA aneuploidy screening.

    PubMed

    Robson, Stephen J; Hui, Lisa

    2015-10-01

    In late 2012, a new screening test for fetal aneuploidy based on circulating cell-free DNA (cfDNA) became available to Australian women. The introduction of this technology in the United States has led to a reduction in invasive diagnostic procedures. Analysis of the number of amniocentesis and chorionic villus sampling (CVS) procedures performed in Australia from 1994 to 2014 shows that the introduction of cfDNA testing has been associated with the most rapid decline in invasive procedures in the last 20 years. This change has important implications for training in, and maintenance of, the procedural skills of amniocentesis and CVS. PMID:26259499

  16. National decline in invasive prenatal diagnostic procedures in association with uptake of combined first trimester and cell-free DNA aneuploidy screening.

    PubMed

    Robson, Stephen J; Hui, Lisa

    2015-10-01

    In late 2012, a new screening test for fetal aneuploidy based on circulating cell-free DNA (cfDNA) became available to Australian women. The introduction of this technology in the United States has led to a reduction in invasive diagnostic procedures. Analysis of the number of amniocentesis and chorionic villus sampling (CVS) procedures performed in Australia from 1994 to 2014 shows that the introduction of cfDNA testing has been associated with the most rapid decline in invasive procedures in the last 20 years. This change has important implications for training in, and maintenance of, the procedural skills of amniocentesis and CVS.

  17. Diagnostic Performance of Endoscopic and Microscopic Procedures for Identifying Different Middle Ear Structures and Remaining Disease in Patients with Chronic Otitis Media: A Prospective Cohort Study

    PubMed Central

    Farahani, Farhad; Shariatpanahi, Elnaz; Jahanshahi, Javane; Poorolajal, Jalal

    2015-01-01

    Background The diagnostic performance of endoscopic and microscopic procedures for detecting diseases of the middle ear in patients with chronic otitis media (COM) has rarely been investigated. This study was conducted to compare the performance of these procedures for identifying middle ear structures and their associated diseases in COM patients. Methods In this prospective cohort study, 58 patients with chronic COM, who were candidates for tympanoplasty with or without a mastoidectomy, were enrolled. Before the surgical intervention, the middle ear was examined via an operating microscope and then through an endoscope to identify the middle ear structures as well as diseases associated with the middle ear. Results The patients were 15 years of age or older. The anatomical parts of the middle ear – the epitympanic, posterior mesotympanic, and hypotympanic structures – were more visible through an endoscope than through a microscope. In addition, the various segments of the mesotympanum, oval window, round window, and Eustachian tube were more visible via endoscopy. The post-operative endoscopic reevaluation of the middle ear revealed that a cholesteatoma had remained in four of 13 patients after surgery. Conclusion According to the results of this study, in cases in which there is poor visibility with the operating microscope or the surgeon suspects remaining disease within the middle ear, endoscopy could be utilized to improve the evaluation of more hidden middle ear pits and structures, particularly if there is a potentially recrudescent pathology. PMID:26167935

  18. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    PubMed Central

    Poulet, Axel; Privat, Maud; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S.

    2016-01-01

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts. PMID:27656653

  19. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    PubMed Central

    Poulet, Axel; Privat, Maud; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S.

    2016-01-01

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts.

  20. A Comparison of Six Different Diagnostic Procedures Used To Check Raw Quantitative Data for Outliers in a Generic Science Education Study.

    ERIC Educational Resources Information Center

    McGinnis, James Randy

    This generic science education study demonstrates the contrast of findings obtained through analyzing all the raw data as opposed to removing various combinations of identified potential outliers provided through the application of six diagnostic procedures. Outliers are defined as extreme data points with large residuals. It is argued that an…

  1. Should excretory urography be used as a routine diagnostic procedure in patients with acute ureteric colic: a single center study.

    PubMed

    Samara, Osama A; Haroun, Dina A; Ashour, Do'a Z; Tarawneh, Emad S; Haroun, Azmi A

    2011-05-01

    The aim of this study was to find an accurate, easily available and safe imaging modality as an alternative to intravenous urography for the diagnosis of acute urinary obstruction. This retrospective study included 332 patients, who underwent both excretory urography (EU) preceeded by plain radiograph as well as ultrasonography for evaluation of acute flank pain. There were 198 male and 134 female patients. The presence or absence of urinary stones, level of obstruction, excretion delay on EU and dilated excretory system on either or both techniques were recorded. The sensitivity, specificity, predictive values, and accuracy for plain radiograph, ultrasonography, and for both modalities together were measured considering EU as a standard reference. The sensitivity and specificity of combined plain radiograph and ultrasound were 97% and 67%, respectively, with positive and negative predictive values and accuracy rates of 92%, 99%, and 97%, respectively. Our study suggests that the combination of plain radiograph and ultrasonography yields a high sensitivity, negative predictive value, and accuracy in depiction of urinary stones. Thus, EU need not be used as a routine diagnostic procedure in patients with acute obstructive uropathy.

  2. [Patient compliance and efficacy of diagnostic procedures in the surveillance of colorectal cancer: experience from a cancer center].

    PubMed

    Riedl, S; Lux, T; Abel, U; Theuer, D

    2005-04-01

    Postoperative surveillance is an important part of the curative therapy of colorectal cancer patients. The effort and effectiveness of these surveillance programs are controversially discussed. We analyzed the practiced follow-up of patients who had undergone a curative resection of colorectal cancer to demonstrate the difficulty to validate the performed surveillance program and to point out possible improvements. For a follow-up period of 37 months (median) we included 530 patients with at least one postoperative examination. 70 patients ended the follow-up prematurely - out of these 56 % quit the surveillance during the first 18 months. Another 68 patients died during the follow-up period. Cancer recurred in 28 % of the patients (n = 109 metastasis, n = 26 local recurrences, 18 patients developed a secondary cancer). 90 % of these recurrences occurred within the first three years. 3525 follow-up examinations took place within 79 months. Patient histories and physical examinations were not helpful for the diagnosis of local recurrences; neither were laboratory routine screenings meaningful. Carcinoembryonic antigen (CEA) and CA 19 - 9 tests, ultrasonographic studies, chest XD-rays and colonoscopic procedures had a higher diagnostic value on the other hand. We demonstrated the problematic nature of the evaluation of different follow-up tests concerning their validity as they were part of a complex postoperative surveillance program. It is also important to point out that the success of the postoperative surveillance depends strongly on the compliance of the patients. To increase this compliance we suggest that the follow-up of patients should be more strongly oriented towards the incidence of recurrences.

  3. Randomized pilot study and qualitative evaluation of a clinical decision support system for brain tumour diagnosis based on SV ¹H MRS: evaluation as an additional information procedure for novice radiologists.

    PubMed

    Sáez, Carlos; Martí-Bonmatí, Luis; Alberich-Bayarri, Angel; Robles, Montserrat; García-Gómez, Juan M

    2014-02-01

    The results of a randomized pilot study and qualitative evaluation of the clinical decision support system Curiam BT are reported. We evaluated the system's feasibility and potential value as a radiological information procedure complementary to magnetic resonance (MR) imaging to assist novice radiologists in diagnosing brain tumours using MR spectroscopy (1.5 and 3.0T). Fifty-five cases were analysed at three hospitals according to four non-exclusive diagnostic questions. Our results show that Curiam BT improved the diagnostic accuracy in all the four questions. Additionally, we discuss the findings of the users' feedback about the system, and the further work to optimize it for real environments and to conduct a large clinical trial. PMID:24480160

  4. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory...

  5. Nuclear medicine practices in the 1950s through the mid-1970s and occupational radiation doses to technologists from diagnostic radioisotope procedures.

    PubMed

    Drozdovitch, Vladimir; Brill, Aaron B; Mettler, Fred A; Beckner, William M; Goldsmith, Stanley J; Gross, Milton D; Hays, Marguerite T; Kirchner, Peter T; Langan, James K; Reba, Richard C; Smith, Gary T; Bouville, André; Linet, Martha S; Melo, Dunstana R; Lee, Choonsik; Simon, Steven L

    2014-10-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, the authors collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s to 1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered I-iodide) to 0.4 μSv (brain scan with 26 MBq of Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using Tc were also estimated. The doses estimated in this study show that the introduction of Tc resulted in an increase in occupational doses per procedure.

  6. NUCLEAR MEDICINE PRACTICES IN THE 1950s THROUGH THE mid-1970s AND OCCUPATIONAL RADIATION DOSES TO TECHNOLOGISTS FROM DIAGNOSTIC RADIOISOTOPE PROCEDURES

    PubMed Central

    Drozdovitch, Vladimir; Brill, Aaron B.; Mettler, Fred A.; Beckner, William M.; Goldsmith, Stanley J.; Gross, Milton D.; Hays, Marguerite T.; Kirchner, Peter T.; Langan, James K.; Reba, Richard C.; Smith, Gary T.; Bouville, André; Linet, Martha S.; Melo, Dunstana R.; Lee, Choonsik; Simon, Steven L.

    2014-01-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, we collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s-1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered 131I-iodide) to 0.4 μSv (brain scan with 26 MBq of 203Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using 99mTc were also estimated. The doses estimated in this study show that the introduction of 99mTc resulted in an increase in occupational doses per procedure. PMID:25162420

  7. Prenatal Diagnosis Procedures and Techniques to Obtain a Diagnostic Fetal Specimen or Tissue: Maternal and Fetal Risks and Benefits.

    PubMed

    Wilson, R Douglas; Gagnon, Alain; Audibert, François; Campagnolo, Carla; Carroll, June; Brock, Jo-Ann; Chong, Karen; Johnson, Jo-Ann; MacDonald, William; Okun, Nanette; Pastuck, Melanie; Vallee-Pouliot, Karine

    2015-07-01

    Objectif : Offrir aux fournisseurs de soins de maternité et à leurs patientes des lignes directrices factuelles contemporaines en ce qui concerne les services de counseling traitant des risques et des avantages maternels propres à la tenue des interventions diagnostiques prénatales orientées par échographie (et/ou des techniques permettant l’établissement d’un diagnostic génétique) nécessaires dans les cas où il a été établi pendant la période prénatale que la grossesse serait exposée à des risques, ainsi qu’en ce qui concerne la prise de décisions subséquentes quant à la prise en charge de la grossesse (questions abordant des aspects tels que le niveau du fournisseur de soins obstétricaux, la surveillance prénatale, le lieu où devraient se dérouler les soins et l’accouchement, et la décision de poursuivre ou d’interrompre la grossesse). La présente directive clinique se limite aux services de counseling traitant des risques et des avantages maternels, et aux décisions en matière de prise en charge de la grossesse pour les femmes qui nécessitent (ou qui envisagent) la mise en œuvre d’une intervention ou d’une technique effractive orientée par échographie aux fins de l’établissement d’un diagnostic prénatal. Population de patientes : Femmes enceintes identifiées, à la suite de la mise en œuvre de protocoles établis de dépistage prénatal (taux sériques maternels ± imagerie, résultats d’analyse de l’ADN acellulaire indiquant des risques élevés, résultats anormaux au moment de l’imagerie fœtale diagnostique ou antécédents familiaux de troubles héréditaires), comme étant exposées à un risque accru d’anomalie génétique fœtale. Ces femmes pourraient nécessiter ou demander des services de counseling au sujet des risques et des avantages pour la grossesse de la tenue d’une intervention effractive orientée par échographie visant à déterminer l’étiologie, le diagnostic, et/ou la

  8. Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 - procedures for the collection of diagnostic blood specimens by venipuncture.

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Introduction: The activities involving phlebotomy, a critical task for obtaining diagnostic blood samples, are poorly studied as regards the major sources of errors and the procedures related to laboratory quality control. The aim of this study was to verify the compliance with CLSI documents of clinical laboratories from South America and to assess whether teaching phlebotomists to follow the exact procedure for blood collection by venipuncture from CLSI/NCCLS H03-A6 - Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture might improve the quality of the process. Materials and methods: A survey was sent by mail to 3674 laboratories from South America to verify the use of CLSI documents. Thirty skilled phlebotomists were trained with the CLSI H03-A6 document to perform venipuncture procedures for a period of 20 consecutive working days. The overall performances of the phlebotomists were further compared before and after the training program. Results: 2622 from 2781 laboratories that did answer our survey used CLSI documents to standardize their procedures and process. The phlebotomists’ training for 20 days before our evaluation completely eliminated non-conformity procedures for: i) incorrect friction of the forearm, during the cleaning of the venipuncture site to ease vein location; ii) incorrect sequence of vacuum tubes collection; and iii) inadequate mixing of the blood in primary vacuum tubes containing anticoagulants or clot activators. Unfortunately the CLSI H03-A6 document does not caution against both unsuitable tourniquet application time (i.e., for more than one minute) and inappropriate request to clench the fist repeatedly. These inadequate procedures were observed for all phlebotomists. Conclusion: We showed that strict observance of the CLSI H03-A6 document can remarkably improve quality, although the various steps for collecting diagnostic blood specimens are not a gold standard, since they may still permit errors. Tourniquet

  9. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  10. Assessment Procedures for Narcissistic Personality Disorder: A Comparison of the Personality Diagnostic Questionnaire-4 and Best-Estimate Clinical Judgments

    ERIC Educational Resources Information Center

    Miller, Joshua D.; Campbell, W. Keith; Pilkonis, Paul A.; Morse, Jennifer Q.

    2008-01-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD)…

  11. Interrelation of Evaluation and Self-Evaluation in the Diagnostic Procedures to Assess Teachers' Readiness for Innovation

    ERIC Educational Resources Information Center

    Tyunnikov, Yurii S.

    2016-01-01

    The paper solves the problem of the relationship of external diagnosis and self-diagnosis of readiness of teachers to innovative activity. It highlights major disadvantages of measurement tools that are used to this process. The author demonstrates an alternative approach to harmonizing the diagnosis, based on a modular diagnostic model, general…

  12. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  13. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical...

  14. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical...

  15. Detection of OXA-48-type carbapenemase-producing Enterobacteriaceae in diagnostic laboratories can be enhanced by addition of bicarbonates to cultivation media or reaction buffers.

    PubMed

    Studentova, Vendula; Papagiannitsis, Costas C; Izdebski, Radoslaw; Pfeifer, Yvonne; Chudackova, Eva; Bergerova, Tamara; Gniadkowski, Marek; Hrabak, Jaroslav

    2015-03-01

    Carbapenemase-mediated resistance to carbapenems in Enterobacteriaceae has become the main challenge in the treatment and prevention of infections recently. The partially unnoticed spread of OXA-48-type carbapenemase producers is usually assigned to low minimum inhibitory concentrations (MICs) of carbapenems that OXA-48-producing isolates often display. Therefore, there is an urgent need of specific and sensitive methods for isolation and detection of OXA-48 producers in clinical microbiology diagnostics. The influence of bicarbonates on carbapenem MICs against carbapenemase-producing Enterobacteriaceae was tested. We also checked whether the addition of bicarbonates to liquid media supplemented with meropenem may facilitate the selective enrichment of various carbapenemase producers in cultures. Furthermore, the sensitivity of carbapenemase confirmation by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) and spectrophotometric hydrolysis assays upon the addition of NH4HCO3 was examined. The addition of NaHCO3 significantly increased MICs of ertapenem and meropenem for OXA-48 producers. Furthermore, liquid media supplemented with NaHCO3 and meropenem were reliable for the selective enrichment of carbapenemase producers. The presence of NH4HCO3 in buffers used in the spectrophotometric and MALDI-TOF MS carbapenemase detection increased the sensitivity of that assay. Our results demonstrate that bicarbonates in media or reaction buffers can enhance the sensitivity of screening methods and diagnostic tests for carbapenemase producers.

  16. Microradiography of Microcalcifications in Breast Specimen: A New Histological Correlation Procedure and the Effect of Improved Resolution on Diagnostic Validity

    PubMed Central

    Langen, H.-J.; Koehler, S.; Bielmeier, J.; Jocher, R.; Kranzfelder, D.; Jagusch, N.; Treutlein, G.; Wetzler, Th.; Müller, J.; Ott, G.

    2012-01-01

    Introduction. Does high-resolution visualization of microcalcifications improve diagnostic reliability? Method. X-rays were taken of mamma specimens with microcalcifications in 32 patients (10 malignant; 22 benign) using conventional radiography (12 Lp/mm) and high-resolution radiography (2000 Lp/mm). Histological sections were subsequently prepared and correlated to the microradiographic image and every calcification was assigned an exact malignant or benign histological diagnosis. Five radiologists classified single groups of calcifications in both methods according to the BIRADS classification system. Results. Using microradiography microcalcifications can be shown in high resolution at the cell level including histological correlation. In some cases, the diagnostic validity was improved by the high resolution in microradiography. In other cases, the high resolution resulted in more visible calcifications, thus giving benign calcifications a malignant appearance. In the BIRADS 2 and 3 group, the probability of malignancy was 28.6% in the conventional radiography evaluation and 37.8% in the microradiography evaluation. In the BIRADS 4 and 5 group, the probability of malignancy was 34.2% in the conventional radiography evaluation and 24.4% in the microradiography evaluation. The differences were not significant. Summary. Overall, the improved resolution in microradiography did not show an improvement in diagnostic accuracy compared to conventional radiography. PMID:23097699

  17. ‘Double Trouble’: Diagnostic Challenges in Duchenne Muscular Dystrophy in Patients with an Additional Hereditary Skeletal Dysplasia

    PubMed Central

    Donkervoort, Sandra; Schindler, Alice; Tesi-Rocha, Carolina; Schreiber, Allison; Leach, Meganne E.; Dastgir, Jahannaz; Hu, Ying; Mankodi, Ami; Wagner, Kathryn R.; Friedman, Neil R.; Bönnemann, Carsten G.

    2015-01-01

    Duchenne muscular dystrophy (DMD) is caused by mutations Dystrophin and affects 1 in 3600-6000 males. It is characterized by progressive weakness, leading to loss of ambulation, respiratory insufficiency, cardiomyopathy, and scoliosis. We describe the unusual phenotype of 3 patients with skeletal dysplasias in whom an additional diagnosis of DMD was later established. Two unrelated boys presented with osteogenesis imperfecta due to point mutations in COL1A1 and were both subsequently found to have a 1bp frameshift deletion in the Dystrophin gene at age 3 and age 15, respectively. The third patient had a diagnosis of pseudoachondroplasia caused by a mutation in the COMP gene and was found to have a deletion of exons 48-50 in Dystrophin at age 9. We discuss the atypical presentation caused by the concomitant presence of 2 conditions affecting the musculoskeletal system, emphasizing aspects that may confound the presentation of a well-characterized disease like DMD. Additional series of patients with DMD and a secondary inherited condition are necessary to establish the natural history in this “double trouble” population. The recognition and accurate diagnosis of patients with two independent genetic disease processes is essential for management, prognosis, genetic risk assessment, and discussion regarding potential therapeutic interventions. PMID:24070816

  18. The modified ultrasound pattern sum score mUPSS as additional diagnostic tool for genetically distinct hereditary neuropathies.

    PubMed

    Grimm, Alexander; Rasenack, Maria; Athanasopoulou, Ioanna M; Dammeier, Nele Maria; Lipski, Christina; Wolking, Stefan; Vittore, Debora; Décard, Bernhard F; Axer, Hubertus

    2016-02-01

    The objective of this study is to evaluate the nerve ultrasound characteristics in genetically distinct inherited neuropathies, the value of the modified ultrasound pattern sum score (mUPSS) to differentiate between the subtypes and the correlation of ultrasound with nerve conduction studies (NCS), disease duration and severity. All patients underwent a standardized neurological examination, ultrasound, and NCS. In addition, genetic testing was performed. Consequently, mUPSS was applied, which is a sum-score of cross-sectional areas (CSA) at predefined anatomical points in different nerves. 31 patients were included (10xCharcot-Marie-Tooth (CMT)1a, 3xCMT1b, 3xCMTX, 9xCMT2, 6xHNPP [Hereditary neuropathy with liability to pressure palsies]). Generalized, homogeneous nerve enlargement and significantly increased UPS scores emphasized the diagnosis of demyelinating neuropathy, particularly CMT1a and CMT1b. The amount of enlargement did not depend on disease duration, symptom severity, height and weight. In CMTX the nerves were enlarged, as well, however, only in the roots and lower limbs, most prominent in men. In CMT2 no significant enlargement was detectable. In HNPP the CSA values were increased at entrapped sites, and not elsewhere. However, a distinction from CMT1, which also showed enlarged CSA values at entrapment sites, was only possible by calculating the entrapment ratios and entrapment score. The mUPSS allowed distinction between CMT1a (increased UPS scores, entrapment ratios <1.0) and HNPP (low UPS scores, entrapment ratios >1.4), while CMT1b and CMTX showed intermediate UPS types and entrapment ratios <1.0. Although based on few cases, ultrasound revealed consistent and homogeneous nerve alteration in certain inherited neuropathies. The modified UPSS is a quantitative tool, which may provide useful information for diagnosis, differentiation and follow-up evaluation in addition to NCS and molecular testing.

  19. Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016.

    PubMed

    Coté, Charles J; Wilson, Stephen

    2016-01-01

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical/dental supervision, careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications, appropriate fasting for elective procedures and a balance between the depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure, a focused airway examination for large (kissing) tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction, a clear understanding of the medication's pharmacokinetic and pharmacodynamic effects and drug interactions, appropriate training and skills in airway management to allow rescue of the patient, age- and size-appropriate equipment for airway management and venous access, appropriate medications and reversal agents, sufficient numbers of staff to both carry out the procedure and monitor the patient, appropriate physiologic monitoring during and after the procedure, a properly equipped and staffed recovery area, recovery to the presedation level of consciousness before discharge from medical/dental supervision, and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children. PMID:27557912

  20. Guidelines for monitoring and management of pediatric patients during and after sedation for diagnostic and therapeutic procedures: an update.

    PubMed

    Coté, Charles J; Wilson, Stephen

    2006-12-01

    The safe sedation of children for procedures requires a systematic approach that includes the following: no administration of sedating medication without the safety net of medical supervision; careful presedation evaluation for underlying medical or surgical conditions that would place the child at increased risk from sedating medications; appropriate fasting for elective procedures and a balance between depth of sedation and risk for those who are unable to fast because of the urgent nature of the procedure; a focused airway examination for large tonsils or anatomic airway abnormalities that might increase the potential for airway obstruction; a clear understanding of the pharmacokinetic and pharmacodynamic effects of the medications used for sedation, as well as an appreciation for drug interactions; appropriate training and skills in airway management to allow rescue of the patient; age- and size-appropriate equipment for airway management and venous access; appropriate medications and reversal agents; sufficient numbers of people to carry out the procedure and monitor the patient; appropriate physiologic monitoring during and after the procedure; a properly equipped and staffed recovery area; recovery to presedation level of consciousness before discharge from medical supervision; and appropriate discharge instructions. This report was developed through a collaborative effort of the American Academy of Pediatrics and the American Academy of Pediatric Dentistry to offer pediatric providers updated information and guidance in delivering safe sedation to children. PMID:17142550

  1. Additive Manufacturing/Diagnostics via the High Frequency Induction Heating of Metal Powders: The Determination of the Power Transfer Factor for Fine Metallic Spheres

    SciTech Connect

    Rios, Orlando; Radhakrishnan, Balasubramaniam; Caravias, George; Holcomb, Matthew

    2015-03-11

    Grid Logic Inc. is developing a method for sintering and melting fine metallic powders for additive manufacturing using spatially-compact, high-frequency magnetic fields called Micro-Induction Sintering (MIS). One of the challenges in advancing MIS technology for additive manufacturing is in understanding the power transfer to the particles in a powder bed. This knowledge is important to achieving efficient power transfer, control, and selective particle heating during the MIS process needed for commercialization of the technology. The project s work provided a rigorous physics-based model for induction heating of fine spherical particles as a function of frequency and particle size. This simulation improved upon Grid Logic s earlier models and provides guidance that will make the MIS technology more effective. The project model will be incorporated into Grid Logic s power control circuit of the MIS 3D printer product and its diagnostics technology to optimize the sintering process for part quality and energy efficiency.

  2. [Clinical relevance of unloading in cartilage therapy of the knee--shoe insoles, knee braces or additional operative procedure?].

    PubMed

    Kraus, T M; Imhoff, A B; Ateschrang, A; Stöckle, U; Schröter, S

    2015-02-01

    Restoration of a neutral biomechanical environment and reduction of overload is an important factor contributing to the success of any cartilage repair procedure. Reduction of overload can by achieved by so called unloading procedures in order to reduce intraarticular pressure from the repair zone. Unloading can be achieved via loss of weight, wedged shoe insoles, knee braces or via operations such as osteotomies around the knee joint. The cartilage therapy and the concomitant unloading procedure should be adapted to the individual pathology and realistic aims of the patient. Wedged insoles and braces are the least invasive treatment methods. In comparison, however, beneficial effects of braces outline those of laterally wedged heels. Nevertheless long-term compliance with insoles and braces is poor. Concerning braces either because the positive effects of the braces are too small or because the adverse effects are too large. Unloading in the long run may only be achieved through operative procedures. When an osteotomy seems to be too invasive the arthroscopic release of the posterior oblique ligament might be an option. Patients with an intact contralateral chondral status, medium to slight malalignment who want to remain at high activity levels, remain good candidates for unloading osteotomies.

  3. Evaluation of interpolation procedures to input turbulence fields from a prognostic model to a diagnostic mass consistent model

    NASA Astrophysics Data System (ADS)

    Trini Castelli, S.; Anfossi, D.

    2009-09-01

    An appropriate description of the meteorology in highly complex terrain encompasses atmospheric processes characterized by all scales of motion, from synoptic scale fronts and waves, through mesoscale mountain-valley circulations and gravity waves, till very small scale turbulence. To study the regional and local circulation at high resolutions (around 100 m) in complex terrain, we often couple a prognostic model (RAMS) to a mass-consistent diagnostic model (MINERVE). This downscaling approach allows representing both the mesoscale forcing and the peculiarities of the local flow in complex topography, since it combines the 3D gridded prognostic fields with local available measurements and it gives the possibility to include a high-resolution detailed topography, thus providing more spatially detailed meteorological fields. Diagnostic atmospheric mass-consistent models generally are used together with turbulence parameterisations defined for flat terrain, thus in principle not able to catch the variability of the turbulence field induced by the presence of complex terrain and inhomogeneous conditions. The possibility of using prognostic turbulence fields produced accounting for the topography is then an appealing approach in inhomogeneous conditions. In this work we investigate whether a proper interpolation from the coarser-resolution prognostic 3D-gridded turbulence fields, like diffusion coefficients, turbulent kinetic energy and its dissipation, might be used in mountainous and inhomogeneous terrain. The final goal is to evaluate if the shortcoming of using parameterised turbulent fields might be overcome when coupling the mass consistent model with a module calculating the turbulence fields at the high-resolution diagnostic grid points, by interpolating from the coarser prognostic grid.

  4. Puumala Hantavirus-Induced Hemorrhagic Fever with Renal Syndrome Must Be Considered across the Borders of Nephrology to Avoid Unnecessary Diagnostic Procedures

    PubMed Central

    Kitterer, Daniel; Segerer, Stephan; Alscher, M. Dominik; Braun, Niko; Latus, Joerg

    2015-01-01

    Background Nephropathia epidemica (NE), a milder form of hemorrhagic fever with renal syndrome, is caused by Puumala virus and is characterized by acute kidney injury and thrombocytopenia. Methods A cross-sectional prospective survey of 456 adult patients with serologically confirmed NE was performed. Results Of the 456 investigated patients, 335 had received inpatient treatment. At time of admission to hospital, 72% of the patients had still an AKI and thrombocytopenia was present in 64% of the patients. The 335 patients were treated in 29 different hospitals and 6 of which had nephrology departments. 10 out of 335 patients received treatment in university hospitals and 63% of patients admitted themselves to hospital. Initially, the patients were admitted to 12 different clinical departments (29% of the patients were referred to a nephrology department) and during the course of the disease, 8% of the patients were transferred to another department in the same hospital and 3% were transferred to a nephrology department at another hospital. Regarding diagnostic procedures, in 28% of the inpatients computed tomography to exclude pulmonary embolism or due to severe gastrointestinal symptoms, lumbar puncture to exclude meningitis, magnetic resonance tomography of the brain owing to suspected stroke because of visual disorders, gastroscopy, or colonoscopy due to gastrointestinal symptoms was performed at time of admission to hospital. Conclusions NE must be considered by physicians across the borders of nephrology to avoid unnecessary diagnostic procedures especially in areas where NE is endemic. PMID:26650941

  5. [Have Case Loads of Radical Surgery for Prostate Cancer Been Concentrated in Hospitals with Robotic Equipment ?--Analyses with Questionnaire Survey and Diagnostic Procedure Combination (DPC) Data].

    PubMed

    Tsukamoto, Taiji; Tanaka, Shigeru

    2016-04-01

    We investigated whether installation of robot-assisted surgical equipment in hospitals resulted in concentration of the case loads of radical prostatectomy. We selected 11 areas with populations of around 1 million or more where there were one or more hospitals with robotic equipment and 4 or more without it. In addition, annual changes of case loads for prostatectomy over 4 years from 2010 to 2013 were clearly determined in these areas. The case loads were determined based on the results of a questionnaire survey for the hospitals with robots and on the Diagnostic Procedures Combination data provided by the Ministry of Health, Labor and Wealth for those without such equipment. The concentration of the case loads was principally defined as when hospitals with robots had more predominant proportion of cases than those without them in the comparison between case loads prior to instillation of robots (or in the initial year of the study) and those in the final years. The 11 selected areas included 44 hospitals with robots and 156 without them. Concentration of case loads was found in 5 areas. In 4 areas, installation of robots did not have a specific relation to the distribution pattern s of case loads in hospitals with or without the equipment. The remaining 2 areas tended to have a weak but not definite concentration of case loads. In the areas in which installation did not influence case loads the further analysis revealed that their case loads had already been concentrated in the initial year (2010) of the study. Although the current results were found in a single department of the hospital, robotic installation may result in concentration of prostatectomy case loads for such hospitals in some areas. The current results are intriguing when we consider the future roles of acute care hospitals and beds in our country where the number of aged patients having chronic diseases will increase. In conclusion, installation of robotic equipment may result in concentration

  6. Characteristics of gastrointestinal stromal tumours, diagnostic procedure and therapeutic management and main directions of nursing practice in gastrointestinal stromal tumours

    PubMed Central

    Głuszek, Stanisław; Kozieł, Dorota

    2014-01-01

    Gastrointestinal stromal tumours (GIST) constitute a separate group of mesenchymal neoplasms of the gastrointestinal tract. They have been commonly recognized for a few years, they have created a new problem in medical practice. GIST are more often centred in the stomach. They equally affect female and male patients and occur mainly in patients older than 50 years of age. The clinical picture of the tumour is non-specific. Radical surgical treatment and molecularly targeted therapy with tyrosine kinase inhibitors are used in GIST treatment. Nursing practice with reference to GIST danger is connected with biopsychosocial interventions of perioperative, oncological and palliative procedures and involves the area of health education mainly oriented towards shaping preventive procedures which favour early disease detection and support therapy and recovery. PMID:25784835

  7. [SICI-GISE position paper on the requirements for diagnostic and interventional procedures in patients with peripheral arterial disease].

    PubMed

    Cremonesi, Alberto; Setacci, Carlo; Rubino, Paolo; Stabile, Eugenio; Castriota, Fausto; Reimers, Bernhard; Inglese, Luigi; Berti, Sergio; Sbarzaglia, Paolo; Biamino, Giancarlo; Guagliumi, Giulio

    2013-10-01

    Interventional procedures on peripheral vessels are the field of a novel specialty dedicated to the diagnosis and minimally invasive endovascular treatment of diseases involving the cerebral, thoracic and abdominal arteries (including renal and visceral arteries), as well as the peripheral arteries (femoro-popliteal arteries and the arteries below the knee). At present, physicians with three different types of medical training, each involving particular strengths and characteristics, specialize in endovascular treatment of patients with peripheral arterial disease: vascular surgeons, interventional radiologists and interventional cardiologists. Treatment of high-risk patients in terms of anatomical and clinical (serious comorbidities) complexity raised the need for the interventional cardiologist to face issues related to technical aspects of the procedure, multilevel pathology management and adequate indication. To achieve this goal, interventional cardiologists require particular facilities and clinical skills. The objectives of this position paper from the Italian Society of Interventional Cardiology (SICI-GISE) are (i) to define the theoretical background and practical training required to ensure that interventional cardiologists maintain high-quality standards also in the field of treatment of peripheral arterial disease, by establishing shared rules and drafting papers; (ii) to standardize the procedures of interventional cardiology operational units that treat patients with peripheral arterial disease in Italy on the basis of scientific evidence, and (iii) to establish common requirements in terms of facilities and regulations. PMID:24121895

  8. Recorded gonorrhoea rates in Denmark, 1900–2010: the impact of clinical testing activity and laboratory diagnostic procedures

    PubMed Central

    Lind, Inga; Hoffmann, Steen

    2015-01-01

    Objectives Assessment of the relations between recorded gonorrhoea rates and clinical testing activity and disposable diagnostic tests. Methods In Denmark, two sources of information on the epidemiology of gonorrhoea are available: (1) a mandatory clinical notification system (since 1867) comprising summary information about geographic distribution, season, age group and gender; in 1994, more detailed anonymous individualised epidemiological information was included; (2) a voluntary countrywide laboratory surveillance system for culture-confirmed cases (since 1957) comprising information about patient's age and gender, infected anatomical sites and medical setting attended. Results Both surveillance systems showed marked simultaneous changes in gonorrhoea rates, although periodically considerable under-reporting or under-diagnosing was demonstrated. The annual incidence of notified cases peaked in 1919 (474/100 000), in 1944 (583/100 000) and in 1972 (344/100 000). Since 1995, the incidence has been at a low endemic level (1.5–10/100 000) and the total male/female incidence ratios were from 3 to 7 times higher than previously recorded. Among approximately 2 million persons tested during 1974–1988 78 213 men and 63 143 women with culture-confirmed gonorrhoea were identified. During this period, pharyngeal sampling was performed in 36% of men and 25% of women with gonorrhoea; pharyngeal gonorrhoea was found in 10% and 16%, respectively; 40% and 30% of these patients had no concomitant urogenital gonorrhoea. Among men with gonorrhoea, 34% were sampled from the rectum; 9% had rectal gonorrhoea, among whom the rectum was the only infected site in 67%. Conclusions Crucial factors for case finding are clinical sampling tradition and appropriate laboratory diagnostic facilities. When case finding is insufficient, a reservoir of asymptomatic rectal or pharyngeal gonorrhoea remains unrecognised. PMID:26621510

  9. 26 CFR 1.23-6 - Procedure and criteria for additions to the approved list of energy-conserving components or...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... geothermal energy, the energy source must be an inexhaustible energy supply. Accordingly, wood and... approved list of energy-conserving components or renewable energy sources. 1.23-6 Section 1.23-6 Internal... During A Taxable Year § 1.23-6 Procedure and criteria for additions to the approved list of...

  10. 26 CFR 1.23-6 - Procedure and criteria for additions to the approved list of energy-conserving components or...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... geothermal energy, the energy source must be an inexhaustible energy supply. Accordingly, wood and... approved list of energy-conserving components or renewable energy sources. 1.23-6 Section 1.23-6 Internal... During A Taxable Year § 1.23-6 Procedure and criteria for additions to the approved list of...

  11. 26 CFR 1.23-6 - Procedure and criteria for additions to the approved list of energy-conserving components or...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... geothermal energy, the energy source must be an inexhaustible energy supply. Accordingly, wood and... approved list of energy-conserving components or renewable energy sources. 1.23-6 Section 1.23-6 Internal... During A Taxable Year § 1.23-6 Procedure and criteria for additions to the approved list of...

  12. 47 CFR 1.420 - Additional procedures in proceedings for amendment of the FM or TV Tables of Allotments, or for...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... amendment of the FM or TV Tables of Allotments, or for amendment of certain FM assignments. 1.420 Section 1... Proceedings Rulemaking Proceedings § 1.420 Additional procedures in proceedings for amendment of the FM or TV... a UHF TV station to a VHF channel in the same community in the course of the rule making...

  13. 47 CFR 1.420 - Additional procedures in proceedings for amendment of the FM or TV Tables of Allotments, or for...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... amendment of the FM or TV Tables of Allotments, or for amendment of certain FM assignments. 1.420 Section 1... Proceedings Rulemaking Proceedings § 1.420 Additional procedures in proceedings for amendment of the FM or TV... a UHF TV station to a VHF channel in the same community in the course of the rule making...

  14. 47 CFR 1.420 - Additional procedures in proceedings for amendment of the FM or TV Tables of Allotments, or for...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... amendment of the FM or TV Tables of Allotments, or for amendment of certain FM assignments. 1.420 Section 1... Proceedings Rulemaking Proceedings § 1.420 Additional procedures in proceedings for amendment of the FM or TV... a UHF TV station to a VHF channel in the same community in the course of the rule making...

  15. 47 CFR 1.420 - Additional procedures in proceedings for amendment of the FM or TV Tables of Allotments, or for...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... amendment of the FM or TV Tables of Allotments, or for amendment of certain FM assignments. 1.420 Section 1... Proceedings Rulemaking Proceedings § 1.420 Additional procedures in proceedings for amendment of the FM or TV... a UHF TV station to a VHF channel in the same community in the course of the rule making...

  16. Left Radial Access Is Preferable to Right Radial Access for the Diagnostic or Interventional Coronary Procedures: A Meta-Analysis Involving 22 Randomized Clinical Trials and 10287 Patients

    PubMed Central

    Guo, Xiaogang; Ding, Jie; Qi, Yue; Jia, Nan; Chu, Shaoli; Lin, Jinxiu; Su, Jinzi; Peng, Feng; Niu, Wenquan

    2013-01-01

    Objective The transradial approach has been used extensively for both diagnostic and interventional coronary procedures; however, there is no universal consensus hitherto on the optimal choice of radial access from either the left or the right artery. We therefore sought to meta-analyze available randomized clinical trials to compare the left with the right radial access for the diagnostic or interventional coronary procedures. Methods and Results Four electronic databases including the PubMed, EMBASE, Wanfang, and CNKI were searched up to April 2013. In total, there were 22 qualified randomized trials involving 5317 and 4970 patients assigned to the left and the right radial accesses, respectively. Data were extracted independently by two investigators. Analyses of the full data set indicated significant reductions in fluoroscopy time (seconds) (weighted mean difference; 95% confidence interval; P: −36.18; −53.28 to −18.53; <0.0005) and contrast use (mL) (−2.88; −5.41 to −0.34; 0.026) in patients with the left radial access compared to those with the right radial access, and there was strong evidence of heterogeneity but low probability of publication bias. The failure rate of radial access from the left was relatively lower than that from the right (odds ratio: 0.83; 95% confidence interval: 0.68−1.01; P = 0.064). Further in meta-regression analyses, body mass index was found to be a potential source of heterogeneity for both fluoroscopy time (regression coefficient: 35.85; P = 0.025) and catheter number (regression coefficient: 0.35; P = 0.018). Conclusions Our findings demonstrate that left radial access is preferable to right radial access in terms of fluoroscopy time and contrast use for the diagnostic or interventional coronary procedures. The import of this study lies in its great shock to the concept of convenient radial access from the right artery. PMID:24223815

  17. Follow-up study of persons who had iodine-131 and other diagnostic procedures during childhood and adolescence

    SciTech Connect

    Hamilton, P.M.; Chiacchierini, R.P.; Kaczmarek, R.G.

    1989-08-01

    A prospective study of 3,503 children and adolescents who received diagnostic doses of iodine-131 was conducted to evaluate the risk of radiation-induced thyroid neoplasia. The exposed group was followed for a total of 93,442 person-years. Thyroid doses received by the exposed group ranged from less than 10 rads to slightly more than 2,000 rads. The majority received less than 100 rads. A group of 2,594 children and adolescents who were not exposed to radioactive iodine comprised the control group for the study. Members of the control group were followed for a total of 66,797 person-years. An elevated risk of malignant thyroid tumors was observed in the exposed group. An increased risk of benign thyroid conditions was also noted in the exposed group. The results described above failed to fulfill the requirements for statistical significance because of the small number of cases but are suggestive of a radiation effect.

  18. NASPE expert consensus document: use of i.v. (conscious) sedation/analgesia by nonanesthesia personnel in patients undergoing arrhythmia specific diagnostic, therapeutic, and surgical procedures.

    PubMed

    Bubien, R S; Fisher, J D; Gentzel, J A; Murphy, E K; Irwin, M E; Shea, J B; Dick, M; Ching, E; Wilkoff, B L; Benditt, D G

    1998-02-01

    Use of IV (Conscious) Sedation/Analgesia by Nonanesthesia Personnel in Patients Undergoing Arrhythmia Specific Diagnostic, Therapeutic, and Surgical Procedures. This article is intended to inform practitioners, payers, and other interested parties of the opinion of the North American Society of Pacing and Electrophysiology (NASPE) concerning evolving areas of clinical practice or technologies or both, that are widely available or are new to the practice community. Expert consensus documents are so designated because the evidence base and experience with the technology or clinical practice are not yet sufficiently well developed, or rigorously controlled trials are not yet available that would support a more definitive statement. This article has been endorsed by the American College of Cardiology, October 1997. PMID:9507538

  19. The crystallinity of calcium phosphate powders influenced by the conditions of neutralized procedure with citric acid additions

    SciTech Connect

    Li Chengfeng

    2009-05-06

    Calcium phosphate powders with nano-sized crystallinity were synthesized by neutralization using calcium hydroxide and orthophosphoric acid with the assistance of citric acid. The influence of processing parameters, such as free or additive citric acid, synthetic temperature and ripening time, on the crystallinity of hydroxyapatite were investigated. The results of X-ray diffraction and microstructure observations showed that the crystallinity and morphology of nano-sized hydroxyapatite particles were influenced by the presence or absence of citric acid. It was found that the crystallinities and crystallite sizes of hydroxyapatite powders prepared with the additive citric acid increased with increasing synthetic temperature and ripening time. Especially, the crystallinities of (h k 0) planes were raised and more homogeneously grown particles were obtained with increasing synthetic temperature.

  20. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    SciTech Connect

    D'Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  1. Bovine tuberculosis: prevalence and diagnostic efficacy of routine meat inspection procedure in Woldiya municipality abattoir north Wollo zone, Ethiopia.

    PubMed

    Aylate, Alemu; Shah, Shahid Nazir; Aleme, Haileluel; Gizaw, Tarkegn Tintagu

    2013-03-01

    Bovine tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology, and molecular methods is not feasible due to lack of resources. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. A cross-sectional study was conducted at Woldiya municipal abattoir from April 1, 2009 to April 5, 2010 to estimate the prevalence of BTB in slaughtered cattle on the basis of detailed abattoir inspection and to compare efficacy of RA inspection with respect to detailed abattoir inspection and isolation and identification of Mycobacterium. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity). Agreement between RA and detailed abattoir inspections was measured using kappa statistics. Out of 1,029 slaughtered heads of cattle examined during the study period, 63 (6.12 %) and 15 (1.45 %) were diagnosed with gross tuberculous lesions by detailed abattoir meat inspections and RA meat inspections, respectively, making a prevalence of 6.12 % (95 % CI: 5.2-7.1) on the basis of detailed abattoir inspection. About 59.45 % of tuberculous lesions were observed in the lungs and associated lymph nodes, whereas 35.13 % lesions were from the lymph nodes of the head. From 63 cattle suspected with tuberculosis (TB) based on detailed abattoir meat inspection, nine (19.05 %) were identified as Mycobacterium bovis, while three (4.8 %) as Mycobacterium tuberculosis. The sensitivity of RA meat inspection was 23.8 % in comparison to the detailed abattoir meat inspection and 25 % in comparison to culture, respectively. Poor agreement (k = 0.37) was seen between RA meat examination and detailed abattoir meat examination methods. Similarly, poor agreement (k = 0.013) was seen between RA meat examination and culture results. In

  2. [Diagnostic and therapeutic procedure for two popular but quite distinct adverse reactions to food - fructose malabsorption and histamine intolerance].

    PubMed

    Reese, I

    2012-04-01

    Claiming to suffer from adverse food reactions is popular. In contrast to the classical food allergy, there are some pathomechanisms which are evidently dose-dependent. Thus the procedure in diagnosis and therapy must undoubtedly differ from the practice when food allergy is suspected or proven. Nevertheless many patients suffering from dose-dependent adverse reactions to food are given strict elimination diets, which is neither necessary nor helpful and decreases their quality of life broadly. This holds especially true for fructose malabsorption and histamine intolerance. For the latter, the term adverse reaction to ingested histamine is preferred, because histamine intolerance implies that symptoms are caused entirely by an enzyme defect. Why this is not very likely to be the only reason is discussed in this article. Both adverse reactions require an individual approach especially with regard to nutrition therapy. Therefore the task of diagnosis should be to establish an individual profile of tolerated and not tolerated foods taking into account that tolerance can greatly vary by meal composition, frequency and individual triggering factors. In view of this, therapeutic recommendations should not be based on the absolute quantities of the eliciting substance to be eliminated but on a feasible transfer into daily life. Thereby food restriction can be minimized and a high quality of life will be maintained.

  3. Acromegaly--a novel view of the patient. Polish proposals for diagnostic and therapeutic procedures in the light of recent reports.

    PubMed

    Bolanowski, Marek; Ruchała, Marek; Zgliczyński, Wojciech; Kos-Kudła, Beata; Bałdys-Waligórska, Agata; Zieliński, Grzegorz; Bednarczuk, Tomasz; Hubalewska-Dydejczyk, Alicja; Kamiński, Grzegorz; Marek, Bogdan; Daroszewski, Jacek; Waśko, Ryszard; Lewiński, Andrzej

    2014-01-01

    is usually delayed and is often associated with the development of various complications causing premature mortality. In patients with hypertension, heart failure, diabetes, and arthropathy that is non-specific for age, attention should be paid to the occurrence of somatic signs of acromegaly. As a screening test, insulin-like growth factor-1 (IGF-1) concentration should be assessed. Further diagnostic and treatment procedures are possible in specialised centres. The first-line therapy is selective transsphenoidal adenomectomy. Patients with a good prognosis related to a surgical removal of the pituitary tumour should be referred only to centres experienced in performing this type of procedure, after pharmacological preparation. Other patients, and those who have not recovered after surgical treatment, should be subjected to long-term pharmacotherapy with long-acting somatostatin analogues. In each case, the complications of acromegaly should be followed-up long-term and actively treated. This proposed new recommendation should be helpful for the management of patients with acromegaly.

  4. Optimization of diagnostic RT-PCR protocols and sampling procedures for the reliable and cost-effective detection of Cassava brown streak virus.

    PubMed

    Abarshi, M M; Mohammed, I U; Wasswa, P; Hillocks, R J; Holt, J; Legg, J P; Seal, S E; Maruthi, M N

    2010-02-01

    Sampling procedures and diagnostic protocols were optimized for accurate diagnosis of Cassava brown streak virus (CBSV) (genus Ipomovirus, family Potyviridae). A cetyl trimethyl ammonium bromide (CTAB) method was optimized for sample preparation from infected cassava plants and compared with the RNeasy plant mini kit (Qiagen) for sensitivity, reproducibility and costs. CBSV was detectable readily in total RNAs extracted using either method. The major difference between the two methods was in the cost of consumables, with the CTAB 10x cheaper (0.53 pounds sterling=US$0.80 per sample) than the RNeasy method (5.91 pounds sterling=US$8.86 per sample). A two-step RT-PCR (1.34 pounds sterling=US$2.01 per sample), although less sensitive, was at least 3-times cheaper than a one-step RT-PCR (4.48 pounds sterling=US$6.72). The two RT-PCR tests revealed consistently the presence of CBSV both in symptomatic and asymptomatic leaves and indicated that asymptomatic leaves can be used reliably for virus diagnosis. Depending on the accuracy required, sampling 100-400 plants per field is an appropriate recommendation for CBSD diagnosis, giving a 99.9% probability of detecting a disease incidence of 6.7-1.7%, respectively. CBSV was detected at 10(-4)-fold dilutions in composite sampling, indicating that the most efficient way to index many samples for CBSV will be to screen pooled samples. The diagnostic protocols described below are reliable and the most cost-effective methods available currently for detecting CBSV.

  5. An epidemiological survey of therapy and diagnostic procedures used by Norwegian small animal practitioners in cases of nasal mite (Pneumonyssoides caninum) infection in dogs.

    PubMed

    Bredal, W P

    1998-09-01

    Forty per cent of the members of the Norwegian Small Animal Veterinary Association (NSAVA) returned a questionnaire regarding the treatment and diagnosis of canine nasal mite infection in their practices in 1996. A total of 2392 dogs were treated for this infection by 156 NSAVA members in clinical practice in that year, averaging 15.3 treated dogs per veterinarian. An estimated minimum of 6000 Norwegian dogs were treated for nasal mite infection in 1996, at an estimated cost of treatment exceeding 3.3 million NOK. Fifty-nine per cent of the practitioners included at least a case history and clinical examination as diagnostic criteria prior to initiating treatment for nasal mite infection. Fewer than 10% routinely performed more thorough diagnostic procedures, and only 1.8% of the diagnoses were verified prior to treatment. A total of 27 different treatment regimens, involving either subcutaneously injected ivermectin or orally administered milbemycin oxime, were routinely used by NSAVA veterinarians to treat these dogs. Seventy-two (53%) of the veterinarians used ivermectin exclusively, 14 (10%) used milbemycin oxime exclusively, while 50 (37%) used both ivermectin and milbemycin oxime. No other drugs were used. Evaluation of treatment was made by assessing resolution of the clinical signs following treatment, and 97% of the veterinarians were satisfied with the effect of the treatment regimen they used. Adverse side-effects following treatment for nasal mite infection in 1996 were seen on 9 occasions; 4 following ivermectin administration and 2 following milbemycin oxime treatment, while in 3 cases no information on the drug used was provided. The risk of adverse reactions to treatment of nasal mite infection in dogs was 0.4%.

  6. The role of a labial salivary gland biopsy in the diagnostic procedure for Sjögren’s syndrome; a study of 94 cases

    PubMed Central

    van Stein-Callenfels, Dewi; Tan, Jonathan; Bloemena, Elisabeth; van Vugt, Richard M.; Voskuyl, Alexandre E.; Santana, Nathalie T.Y.

    2014-01-01

    Objectives: The purpose of the present study is to examine the role of the outcome of the labial salivary gland biopsy (LSGB) in the diagnostic procedure of patients suspected of suffering from Sjögren’s syndrome (SS). Material and Methods: In a retrospective study the result of histopathological assessment of 94 consecutively taken labial salivary gland biopsies has been examined. For the diagnosis of SS the American-European Consensus Group classification (AECG, 2002) have been used. The outcome of the assessment has been discussed in relation to a recently reported classification provided by the American College of Rheumatology (ACR, 2012). Results: In the 94 LSGBs support for a diagnosis of SS has been encountered in 24 out of 26 patients with SS. In the 68 patients with a negative diagnosis of SS only six positive LSGBs were observed. The sensitivity of the labial biopsy amounted 0.92; the specificity was 0.91, while the positive predictive value and the negative predictive value amounted 0.80 and 0.97 respectively. LSGBs taken by or on the request of the departments of Rheumatology or Internal Medicine had a significant higher yield compared to LSGBs taken in other clinical departments. Conclusions: The LSGB may play a role in the diagnostic procedure of Sjögren’s syndrome when using either the AECG classification or the ACR classification. A LSGB should preferably taken after counseling for the possible presence of SS by a department of Rheumatology or Internal Medicine since the yield of such biopsies is much higher than in patients who have not been counseled by these departments prior to the taking of a LSGB. When using the ACR classification, a positive serologic result and a positive ocular test make the taking of a LSGB redundant. Only in case of a negative serologic outcome or a negative result of the ocular test a LSGB is indicated. Since both the serologic test and the ocular test carry hardly any morbidity, these tests should, indeed, be

  7. Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures

    SciTech Connect

    Brady, Samuel; Yoshizumi, Terry; Toncheva, Greta; Frush, Donald; and others

    2010-09-15

    the main axis of the CT beam. The consistency in dose response difference allowed for a tissue specific correction to be applied. Once corrected, the average film response agreed to better than 3%(SD{+-}2%) for the CTDI scans, and for the anthropomorphic phantom scans: 3%(SD{+-}3%) for the lungs, 5%(SD{+-}3%) for the liver, and 4%(SD{+-}3%) for the kidneys. Additionally, XRQA film measured a heterogeneous dose distribution within the organ volumes. The extent of the dose distribution heterogeneity was not measurable with the TLDs due to the limitation on the number of TLDs loadable in the regions of the phantom organs. In this regard, XRQA film demonstrated an advantage over the TLD method by discovering a 15% greater maximum dose to lung in a region unmeasured by TLDs. Conclusions: The films demonstrated a lower sensitivity to absorbed dose measurements due to the geometric inefficiency of measuring dose from a beam situated end-on to the film. Once corrected, the film demonstrated equivalent dose measurement accuracy as TLD detectors with the added advantage of relatively simple measurement of high-resolution dose distributions throughout organ volumes.

  8. Proteinuria: diagnostic principles and procedures.

    PubMed

    Abuelo, J G

    1983-02-01

    Proteinuria has been thought of as the first sign of serious renal disease. However, in some patients proteinuria may last for years without other evidence of kidney damage, and in other patients it may only be an insignificant and transient laboratory finding. The nature and severity of renal involvement in a particular patient are often suggested by the clinical picture, and the pattern and amount of proteinuria. The physician should use this information in evaluating the severity of the patient's disease. An approach for such evaluations is offered by briefly reviewing the causes and prognosis of the various types of proteinuria and by suggesting steps to take in treating patients with increased protein excretion.

  9. Neurological Diagnostic Tests and Procedures

    MedlinePlus

    ... than an hour. Magnetic resonance imaging (MRI) uses computer-generated radio waves and a powerful magnetic field ... signal at different angles within the body. A computer processes this resonance into either a three-dimensional ...

  10. Diagnostic imaging.

    PubMed

    Morris, Peter; Perkins, Alan

    2012-04-21

    Physical techniques have always had a key role in medicine, and the second half of the 20th century in particular saw a revolution in medical diagnostic techniques with the development of key imaging instruments: x-ray imaging and emission tomography (nuclear imaging and PET), MRI, and ultrasound. These techniques use the full width of the electromagnetic spectrum, from gamma rays to radio waves, and sound. In most cases, the development of a medical imaging device was opportunistic; many scientists in physics laboratories were experimenting with simple x-ray images within the first year of the discovery of such rays, the development of the cyclotron and later nuclear reactors created the opportunity for nuclear medicine, and one of the co-inventors of MRI was initially attempting to develop an alternative to x-ray diffraction for the analysis of crystal structures. What all these techniques have in common is the brilliant insight of a few pioneering physical scientists and engineers who had the tenacity to develop their inventions, followed by a series of technical innovations that enabled the full diagnostic potential of these instruments to be realised. In this report, we focus on the key part played by these scientists and engineers and the new imaging instruments and diagnostic procedures that they developed. By bringing the key developments and applications together we hope to show the true legacy of physics and engineering in diagnostic medicine. PMID:22516558

  11. Fungal Diagnostics

    PubMed Central

    Kozel, Thomas R.; Wickes, Brian

    2014-01-01

    Early diagnosis of fungal infection is critical to effective treatment. There are many impediments to diagnosis such as a diminishing number of clinical mycologists, cost, time to result, and requirements for sensitivity and specificity. In addition, fungal diagnostics must meet the contrasting needs presented by the increasing diversity of fungi found in association with the use of immunosuppressive agents in countries with high levels of medical care and the need for diagnostics in resource-limited countries where large numbers of opportunistic infections occur in patients with AIDS. Traditional approaches to diagnosis include direct microscopic examination of clinical samples, histopathology, culture, and serology. Emerging technologies include molecular diagnostics and antigen detection in clinical samples. Innovative new technologies that use molecular and immunoassay platforms have the potential to meet the needs of both resource-rich and resource-limited clinical environments. PMID:24692193

  12. Extending Vaidyanathan's procedure to improve the performance of unitary filter banks with a fixed lowpass by using additional elementary building blocks

    NASA Astrophysics Data System (ADS)

    Steffen, Peter; Brandhuber, Wolfgang

    2007-09-01

    Wavelet decomposition of signals using the classical Daubechies-Wavelets could also be considered as a decomposition using a filter bank with two channels, a low pass and a high pass channel, represented by the father and mother wavelet, respectively. By generalizing this two channel approach filter banks with N >= 2 channels can be constructed. They possess one scaling function or father wavelet representing the low pass filter and one, two or more mother wavelets representing band pass filters. The resulting band pass filters do not show a satisfactory selective behavior, in general. Hence, a modification of the generalized design seems appropriate. Based on Vaidyanathan's procedure we developed a method to modify the modulation matrix under the condition that the low pass is unchanged and the degree of the band pass filters is not increased. This can be achieved by introducing one or more additional elementary building blocks under certain orthogonality constraints with respect to their generating vectors. While the (polynomial) degree of the modulation matrix remains unchanged, its complexity increases due to its increased McMillan degree.

  13. Diagnostic and forensic toxicology.

    PubMed

    Galey, F D

    1995-12-01

    In most competent veterinary diagnostic laboratories, analytical findings are interpreted by the veterinary toxicologist to determine the significance of the finding in view of historic, clinical, and pathologic findings. A veterinary toxicologist also will provide consultation about possible toxic rule-outs for a case, treatment of affected animals, and prevention of additional cases. Once all of the information is available, a complete summary of the findings can be provided to the client. When the procedures outlined are followed, including a systematic approach to collecting all the evidence (historic, clinical, pathologic, and analytic), proper sampling techniques, and good communication between the clinician and the client and laboratory, the usefulness of the toxicology investigation will be maximized.

  14. A Critical Review of Screening and Diagnostic Instruments for Autism Spectrum Disorders in People with Sensory Impairments in Addition to Intellectual Disabilities

    ERIC Educational Resources Information Center

    de Vaan, Gitta; Vervloed, Mathijs P. J.; Hoevenaars-van den Boom, Marella; Antonissen, Anneke; Knoors, Harry; Verhoeven, Ludo

    2016-01-01

    Instruments that are used for diagnosing of, or screening for, autism spectrum disorder (ASD) may not be applicable to people with sensory disabilities in addition to intellectual disabilities. First, because they do not account for equifinality, the possibility that different conditions may lead to the same outcome. Second, because they do not…

  15. A novel, non-invasive diagnostic clinical procedure for the determination of an oxygenation status of chronic lower leg ulcers using peri-ulceral transcutaneous oxygen partial pressure measurements: results of its application in chronic venous insufficiency (CVI).

    PubMed

    Barnikol, Wolfgang K R; Pötzschke, Harald

    2012-01-01

    The basis for the new procedure is the simultaneous transcutaneous measurement of the peri-ulceral oxygen partial pressure (tcPO(2)), using a minimum of 4 electrodes which are placed as close to the wound margin as possible, additionally, as a challenge the patient inhales pure oxygen for approximately 15 minutes. In order to evaluate the measurement data and to characterise the wounds, two new oxygen parameters were defined: (1) the oxygen characteristic (K-PO(2)), and (2) the oxygen inhomogeneity (I-PO(2)) of a chronic wound. The first of these is the arithmetic mean of the two lowest tcPO(2) measurement values, and the second is the variation coefficient of the four measurement values. Using the K-PO(2) parameter, a grading of wound hypoxia can be obtained. To begin with, the physiologically regulated (and still compensated) hypoxia with K-PO(2) values of between 35 and 40 mmHg is distinguished from the pathological decompensated hypoxia with K-PO(2) values of between 0 and 35 mmHg; the first of these still stimulates self-healing (within the limits of the oxygen balance). The decompensated hypoxia can be (arbitrarily) divided into "simple" hypoxia (Grade I), intense hypoxia (Grade II) and extreme hypoxia (Grade III), with the possibility of intermediate grades (I/II and II/III).Measurements were carried out using the new procedure on the skin of the right inner ankle of 21 healthy volunteers of various ages, and in 17 CVI (chronic venous insufficiency) wounds. Sixteen of the 17 CVI wounds (i.e., 94%) were found to be pathologically hypoxic, a state which was not found in any of the healthy volunteers. The oxygen inhomogeneity (I-PO(2)) of the individual chronic wounds increased exponentially as a function of the hypoxia grading (K-PO(2)), with a 10-fold increase with extreme hypoxia in contrast to a constant value of approximately 14% in the healthy volunteers. This pronounced oxygen inhomogeneity explains inhomogeneous wound healing, resulting in the so

  16. Frequency of use of diagnostic and manual therapeutic procedures of the spine taught at the Canadian Memorial Chiropractic College: A preliminary survey of Ontario chiropractors. Part 1 – practice characteristics and demographic profiles

    PubMed Central

    Gleberzon, Brian; Stuber, Kent

    2013-01-01

    Background: Students learn a plethora of physical examination and manual therapy procedures over the course of their chiropractic education. However, it is uncertain to what extent they continue to use these procedures in practice after graduation. Objective: The purpose of this study was to determine which diagnostic and therapeutic procedures of the spine are most commonly utilized by chiropractors practicing in Ontario. In Part 1 of this study (presented here), the demographics and practice patterns of the respondents are presented. Part 2 of this study will present the results of the utilization rates of diagnostic and therapeutic procedures used by respondents. Methods: The study consisted of a paper-based survey that was sent to 500 pseudo-randomly selected Ontario chiropractors who responded confidentially. Survey questions inquired into demographic and practice style characteristics. Results: There were 108 respondents to the survey, giving a response rate of 22.4%. Many chiropractors self-identified themselves with more than one practice style characteristic such as 72.4% of the self-described pain-based chiropractors who also described themselves as evidence-based, compared with 51.9% of subluxation-based chiropractors who also described themselves as evidence-based. Diversified technique was the most commonly employed technique used by 90.7% of respondents, followed by trigger point therapy indicated by 57.4% of respondents. Conclusions: Despite a low response rate, respondents reported practice characteristics in this study that were similar to practice characteristics previously published, particularly in terms of professional demographics and techniques employed. While Diversified was the most commonly used technique, respondents reported higher levels of use of proprietary soft tissue techniques systems and upper cervical techniques than have been previously reported. PMID:23482716

  17. Dermatofibrosarcoma protuberans: dealing with slow Mohs procedures employing formalin-fixed, paraffin wax-embedded tissue in a busy diagnostic laboratory.

    PubMed

    Orchard, G E; Shams, M

    2012-01-01

    Dermatofibrosarcoma protuberans (DFSP) is a relatively uncommon tumour that arises in the dermis and underlying soft tissue. Surgical removal is the preferred treatment, with relatively wide clearance margins of 3 cm or more. Slow Mohs procedures are often employed successfully to treat patients with such tumours. Slow Mohs procedures offer the benefit of improved cure rates and maximal tissue conservation. However, dealing with such tissue successfully presents the laboratory with a host of technical problems. This report advocates a set protocol to follow for slow Mohs, based on the experience acquired from dealing with 37 cases of DFSP over a 12-year period. The report establishes the benefits of slow Mohs paraffin wax-embedded tissue over frozen sections in terms of improved morphology, tissue preservation and immunocytochemical labelling with anti-CD34.

  18. Effect of whey protein concentrate and sodium chloride addition plus tumbling procedures on technological parameters, physical properties and visual appearance of sous vide cooked beef.

    PubMed

    Szerman, N; Gonzalez, C B; Sancho, A M; Grigioni, G; Carduza, F; Vaudagna, S R

    2007-07-01

    Beef muscles cooked by the sous vide system were evaluated for the effects of pre-injection tumbling, brine addition and post-injection tumbling on technological parameters, physical properties, visual appearance and tissue microstructure. The muscles were injected at 120% (over original weight) with a brine formulated to give a concentration of 3.5% whey protein concentrate and 0.7% sodium chloride on an injected raw product basis. Pre-injection tumbling did not affect most of the evaluated parameters. Brine addition reduced significantly the cooking and total weight losses. Total weight loss was 7.2% for injected muscles, and significantly higher (28.2%) for non-injected ones. Brine incorporation increased pH and reduced shear force values of cooked muscles. Extended post-injection tumbling (5rpm-10h) improved brine distribution and visual appearance, and also diminished the shear force values of cooked muscles. However, this treatment increased the weight losses of post-injection tumbling and cooking-pasteurization stages. PMID:22060988

  19. Effect of whey protein concentrate and sodium chloride addition plus tumbling procedures on technological parameters, physical properties and visual appearance of sous vide cooked beef.

    PubMed

    Szerman, N; Gonzalez, C B; Sancho, A M; Grigioni, G; Carduza, F; Vaudagna, S R

    2007-07-01

    Beef muscles cooked by the sous vide system were evaluated for the effects of pre-injection tumbling, brine addition and post-injection tumbling on technological parameters, physical properties, visual appearance and tissue microstructure. The muscles were injected at 120% (over original weight) with a brine formulated to give a concentration of 3.5% whey protein concentrate and 0.7% sodium chloride on an injected raw product basis. Pre-injection tumbling did not affect most of the evaluated parameters. Brine addition reduced significantly the cooking and total weight losses. Total weight loss was 7.2% for injected muscles, and significantly higher (28.2%) for non-injected ones. Brine incorporation increased pH and reduced shear force values of cooked muscles. Extended post-injection tumbling (5rpm-10h) improved brine distribution and visual appearance, and also diminished the shear force values of cooked muscles. However, this treatment increased the weight losses of post-injection tumbling and cooking-pasteurization stages.

  20. Application of flow injection gradient titration based on the standard addition and dilution procedure to the determination of total acidity in vinegars and soft drinks.

    PubMed

    Wójtowicz, Marzena; Kozak, Joanna; Górnacka, Dorota; Koscielniak, Pawel

    2008-12-01

    The proposed approach relies on successive dilution of a solution containing a sample with standard addition and on titration of the solutions obtained until receiving a signal lower than the signal measured for the sample alone. Equations are derived for subsequent dilution factors for the automatic flow injection system applied. The overall calibration strategy including the possibility of prediction of the number of required standard solutions and of positioning the sample signal within the calibration range is presented. The method has been tested on the spectrophotometric determination of hydrochloric acid at two concentration levels (0.193 and 1.21 mol L(-1)) with sodium hydroxide as titrant. The results of accuracy better than |3.9|% (RE) and repeatability better than 1.3% (RSD) were obtained. The method has been applied to the determination of total acidity in vinegars and soft drinks. The average time necessary to analyze one sample is about 10 min. PMID:19075470

  1. Antiserum raised in pigs against canine distemper virus and its utility in diagnostic procedures for morbillivirus infections (canine distemper, phocine distemper, rinderpest).

    PubMed

    Zaghawa, A; Liess, B; Frey, H R

    1990-07-01

    Antiserum against canine distemper virus (CDV) was raised in pigs by intranasal inoculation with CDV strains CND65 and ROCKBORN. Immunoglobulin fractions were conjugated with horseradish peroxidase. Peroxidase-conjugated anti-CDV immunoglobulin preparations were used for the detection and titration of CDV, seal-derived (phocine) distemper virus (PDV) and rinderpest virus (RPV) in Vero cell cultures. For the detection and titration of corresponding neutralizing antibodies a direct neutralizing peroxidase-linked antibody (NPLA) assay was established. The results were compared with those obtained with the conventional microtitre neutralization test (MNT) based on CPE reading. In addition the sensitivity of an indirect peroxidase-linked antibody (PLA) assay was tested in parallel with that of the NPLA assay using sera obtained from CDV-immunized pigs.

  2. Predictable diastema reduction with filled resin: diagnostic wax-up.

    PubMed

    Newitter, D A

    1986-03-01

    A method for predictably altering anterior esthetics with composite resins is presented. The diagnostic wax-up is the key element. It is used to make a patient presentation cast and to customize resin forms. The resin forms are used to reproduce the predicted tooth form in the mouth quickly and accurately. The method should alert the dentist to the technical feasibility of the planned treatment and the difficulties that may be encountered. In addition, it should alleviate potential misunderstanding and disappointment of the patient. Finally, diagnostic waxing is time saving and simplifies the chairside procedure.

  3. Production Pathways and Separation Procedures for High-Diagnostic-Value Activation Species, Fission Products, and Actinides Required for Preparation of Realistic Synthetic Post-Detonation Nuclear Debris: Status Report and FY16 Project Plan

    SciTech Connect

    Faye, S. A.; Shaughnessy, D. A.

    2015-08-19

    The objective of this project is to provide a comprehensive study on the production routes and chemical separation requirements for activation products, fission products, and actinides required for the creation of realistic post-detonation surrogate debris. Isotopes that have been prioritized by debris diagnosticians will be examined for their ability to be produced at existing irradiation sources, production rates, and availability of target materials, and chemical separation procedures required to rapidly remove the products from the bulk target matrix for subsequent addition into synthetic debris samples. The characteristics and implications of the irradiation facilities on the isotopes of interest will be addressed in addition to a summary of the isotopes that are already regularly produced. This is a planning document only.

  4. Molecular Diagnostics

    PubMed Central

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid, polymerase chain reaction–based detection of bacterial genes, and metabolomic determination of responses to orthopaedic infection. PMID:25808967

  5. Cable Diagnostic Focused Initiative

    SciTech Connect

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  6. Dosimetry in diagnostic radiology.

    PubMed

    Meghzifene, Ahmed; Dance, David R; McLean, Donald; Kramer, Hans-Michael

    2010-10-01

    Dosimetry is an area of increasing importance in diagnostic radiology. There is a realisation amongst health professionals that the radiation dose received by patients from modern X-ray examinations and procedures can be at a level of significance for the induction of cancer across a population, and in some unfortunate instances, in the acute damage to particular body organs such as skin and eyes. The formulation and measurement procedures for diagnostic radiology dosimetry have recently been standardised through an international code of practice which describes the methodologies necessary to address the diverging imaging modalities used in diagnostic radiology. Common to all dosimetry methodologies is the measurement of the air kerma from the X-ray device under defined conditions. To ensure the accuracy of the dosimetric determination, such measurements need to be made with appropriate instrumentation that has a calibration that is traceable to a standards laboratory. Dosimetric methods are used in radiology departments for a variety of purposes including the determination of patient dose levels to allow examinations to be optimized and to assist in decisions on the justification of examination choices. Patient dosimetry is important for special cases such as for X-ray examinations of children and pregnant patients. It is also a key component of the quality control of X-ray equipment and procedures. PMID:20655679

  7. The Use of Information Based Evaluation in Evaluating the Diagnostic Teaching Center.

    ERIC Educational Resources Information Center

    Poteet, James A.

    Information Based Evaluation (IBE) is identified as a design procedure for assessing a variety of projects, programs, and educational changes. IBE was used to evaluate a Comprehensive Diagnostic Teaching Center (DTC) which, in addition to providing teacher training and services to handicapped pupils, would bring together and focus all of the…

  8. [Intolerance to food additives: an update].

    PubMed

    Cardinale, F; Mangini, F; Berardi, M; Sterpeta Loffredo, M; Chinellato, I; Dellino, A; Cristofori, F; Di Domenico, F; Mastrototaro, M F; Cappiello, A; Centoducati, T; Carella, F; Armenio, L

    2008-12-01

    Contrary to common believing, the prevalence of the intolerance to food additives in the general population is rather low. Nowadays many doubts persist with regard both to the pathogenetic mechanisms and to the clinical and diagnostic aspects in this field. Symptoms due to, or exacerbated from, food additives usually involve non-IgE-mediate mechanisms (pseudo-allergic reactions, PAR) and are usually less severe of those induced by food allergy. The most frequent clinical feature of the intolerance to food additives still remains the urticaria-angioedema syndrome, although these substances are really involved only in a minority of patients. Other possible clinical features include anaphylaxis, atopic eczema, behaviour disturbances, asthma and non-allergic rhinitis. The diagnostic approach consists in diary cards, reporting symptoms and food habits, elimination diet and double blinded placebo-controlled oral challenge with suspected additives. However, such procedure still remains poorly standardized and numerous uncertainties persist with regard to optimal conditions for performing and interpret the challenge results. The therapeutic approach consists in the exclusion of foods and products containing the additive involved, and, in patients not compliant to the diet, in treatment with symptomatic drugs.

  9. Direct addition of cultures of tester bacteria into semi-permeable membrane devices (SPMDs) as a modified procedure for preliminary detection of mutagenic pollution of the marine environment by use of microbiological mutagenicity assays.

    PubMed

    Cheć, Ewa; Podgórska, Beata; Wegrzyn, Grzegorz

    2006-12-10

    Mutagenic pollution of the natural environment, including marine waters, is a very serious ecological problem. However, since chemical mutagens usually occur and act at low concentrations, their detection and identification is technically difficult, laborious and time-consuming. Therefore, preliminary detection of mutagenic pollution is commonly based on biological mutagenicity assays. On the other hand, triolein-containing semi-permeable membrane devices (SPMDs) provide a method for concentration of hydrophobic organic contaminants, including a large fraction of the mutagens. Combinations of SPMDs with microbiological toxicity and mutagenicity assays have already been described, but only SPMD-derived extracts, prepared with various organic solvents, were tested in such a way to date. We found that the presence of these solvents could interfere with the Vibrio harveyi bioluminescence-based mutagenicity assay. Moreover, preparation of the extracts from SPMD takes usually at least 48h. Here, we propose a modified procedure, based on direct addition of tester bacteria cultures into SPMD. We found that this procedure is significantly (at least two times) more rapid and several times more sensitive than that based on testing the extracts. This optimization is presented in this report. Moreover, we have performed preliminary studies on samples of marine waters. Positive results (i.e. detection of mutagenic activity) were obtained when test samples came from a region known to be highly contaminated by industrial pollution, while negative results were observed in the case of samples from a region supposed to be of low risk for mutagenic pollution.

  10. Children’s Exposure to Diagnostic Medical Radiation and Cancer Risk: Epidemiologic and Dosimetric Considerations

    PubMed Central

    Linet, Martha S.; Kim, Kwang pyo; Rajaraman, Preetha

    2009-01-01

    While the etiology of most childhood cancers is largely unknown, epidemiologic studies have consistently found an association between exposure to medical radiation during pregnancy and risk of childhood cancer in offspring. The relation between early life diagnostic radiation exposure and occurrence of pediatric cancer risks is less clear. This review summarizes current and historical estimated doses for common diagnostic radiologic procedures as well as the epidemiologic literature on the role of maternal prenatal, children’s postnatal and parental preconception diagnostic radiologic procedures on subsequent risk of childhood malignancies Risk estimates are presented according to factors such as the year of birth of the child, trimester and medical indication for the procedure, and the number of films taken. The paper also discusses limitations of the methods employed in epidemiologic studies to assess pediatric cancer risks, the effects on clinical practice of the results reported from the epidemiologic studies, and clinical and public health policy implications of the findings. Gaps in understanding and additional research needs are identified. Important research priorities include nationwide surveys to estimate fetal and childhood radiation doses from common diagnostic procedures, and epidemiologic studies to quantify pediatric and lifetime cancer risks from prenatal and early childhood exposures to diagnostic radiography, computed tomography, and fluoroscopically-guided procedures. PMID:19083224

  11. [Ultrasound diagnostics in ophthalmology (standardized echography): part 2: diseases of the orbit - ultrasound biomicroscopy diagnostics].

    PubMed

    Hasenfratz, G; Mardin, C

    2014-11-01

    Ultrasound diagnostics have been one of the most important noninvasive supplementary diagnostic procedures in ophthalmology for many decades and are indispensable for many intraocular and orbital diseases. When the echography examination and analysis of the echograms obtained are correctly carried out, ultrasound diagnostics are characterized by a high measure of specificity and sensitivity.

  12. Combining principles of Cognitive Load Theory and diagnostic error analysis for designing job aids: Effects on motivation and diagnostic performance in a process control task.

    PubMed

    Kluge, Annette; Grauel, Britta; Burkolter, Dina

    2013-03-01

    Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control.

  13. Myasthenia Gravis: Tests and Diagnostic Methods

    MedlinePlus

    ... Affiliations Foundation Focus Newsletter E-Update Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events Spring 2016 ...

  14. Knowledge based jet engine diagnostics

    NASA Technical Reports Server (NTRS)

    Jellison, Timothy G.; Dehoff, Ronald L.

    1987-01-01

    A fielded expert system automates equipment fault isolation and recommends corrective maintenance action for Air Force jet engines. The knowledge based diagnostics tool was developed as an expert system interface to the Comprehensive Engine Management System, Increment IV (CEMS IV), the standard Air Force base level maintenance decision support system. XMAM (trademark), the Expert Maintenance Tool, automates procedures for troubleshooting equipment faults, provides a facility for interactive user training, and fits within a diagnostics information feedback loop to improve the troubleshooting and equipment maintenance processes. The application of expert diagnostics to the Air Force A-10A aircraft TF-34 engine equipped with the Turbine Engine Monitoring System (TEMS) is presented.

  15. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  16. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  17. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  18. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  19. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  20. Diagnostic Imaging

    MedlinePlus

    Diagnostic imaging lets doctors look inside your body for clues about a medical condition. A variety of machines and techniques can create pictures of the structures and activities inside your body. The type of imaging your doctor uses depends on your symptoms and ...

  1. Chronic pancreatitis: A diagnostic dilemma

    PubMed Central

    Duggan, Sinead N; Ní Chonchubhair, Hazel M; Lawal, Oladapo; O’Connor, Donal B; Conlon, Kevin C

    2016-01-01

    Typical clinical symptoms of chronic pancreatitis are vague and non-specific and therefore diagnostic tests are required, none of which provide absolute diagnostic certainly, especially in the early stages of disease. Recently-published guidelines bring much needed structure to the diagnostic work-up of patients with suspected chronic pancreatitis. In addition, novel diagnostic modalities bring promise for the future. The assessment and diagnosis of pancreatic exocrine insufficiency remains challenging and this review contests the accepted perspective that steatorrhea only occurs with > 90% destruction of the gland. PMID:26900292

  2. Common rodent procedures.

    PubMed

    Klaphake, Eric

    2006-05-01

    Rodents are commonly owned exotic animal pets that may be seen by veterinary practitioners. Although most owners presenting their animals do care about their pets, they may not be aware of the diagnostic possibilities and challenges that can be offered by rodents to the veterinarian. Understanding clinical anatomy, proper hand-ling technique, realistic management of emergency presentations,correct and feasible diagnostic sampling, anesthesia, and humane euthanasia procedures is important to enhancing the doctor-client-patient relationship, especially when financial constraints may be imposed by the owner. PMID:16759953

  3. Progress on US ITER Diagnostics

    NASA Astrophysics Data System (ADS)

    Johnson, David; Feder, Russ

    2010-11-01

    There have been significant advances in the design concepts for the 8 ITER diagnostic systems being provided by the US. Concepts for integration of the diagnostics into the port plugs have also evolved. A prerequisite for the signoff of the procurement arrangements for these each diagnostic is a Conceptual Design Review organized by the ITER Organization. US experts under contract with the USIPO have been assisting the IO to prepare for these Reviews. In addition, a design team at PPPL has been working with these experts and designers from other ITER parties to package diagnostic front-ends into the 5 US plugs. Modular diagnostic shield modules are now being considered in order to simplify the interfaces between the diagnostics within each plug. Diagnostic first wall elements are envisioned to be integral with these shield modules. This simplifies the remote handling of the diagnostics and provides flexibility for future removal of one diagnostic minimally affecting others. Front-end configurations will be presented, along with lists of issues needing resolution prior to the start of preliminary design.

  4. Diagnostics development plan for ZR.

    SciTech Connect

    Hanson, David Lester

    2003-09-01

    The Z Refurbishment (ZR) Project is a program to upgrade the Z machine at SNL with modern durable pulsed power technology, providing additional shot capacity and improved reliability as well as advanced capabilities for both pulsed x-ray production and high pressure generation. The development of enhanced diagnostic capabilities is an essential requirement for ZR to meet critical mission needs. This report presents a comprehensive plan for diagnostic instrument and infrastructure development for the first few years of ZR operation. The focus of the plan is on: (1) developing diagnostic instruments with high spatial and temporal resolution, capable of low noise operation and survival in the severe EMP, bremsstrahlung, and blast environments of ZR; and (2) providing diagnostic infrastructure improvements, including reduced diagnostic trigger signal jitter, more and flexible diagnostic line-of-sight access, and the capability for efficient exchange of diagnostics with other laboratories. This diagnostic plan is the first step in an extended process to provide enhanced diagnostic capabilities for ZR to meet the diverse programmatic needs of a broad range of defense, energy, and general science programs of an international user community into the next decade.

  5. Food additives

    PubMed Central

    Spencer, Michael

    1974-01-01

    Food additives are discussed from the food technology point of view. The reasons for their use are summarized: (1) to protect food from chemical and microbiological attack; (2) to even out seasonal supplies; (3) to improve their eating quality; (4) to improve their nutritional value. The various types of food additives are considered, e.g. colours, flavours, emulsifiers, bread and flour additives, preservatives, and nutritional additives. The paper concludes with consideration of those circumstances in which the use of additives is (a) justified and (b) unjustified. PMID:4467857

  6. A randomized controlled trial to assess the impact of dietary energy sources, feed supplements, and the presence of super-shedders on the detection of Escherichia coli O157:H7 in feedlot cattle using different diagnostic procedures.

    PubMed

    Cernicchiaro, Natalia; Pearl, David L; McEwen, Scott A; Zerby, Henry N; Fluharty, Francis L; Loerch, Steve C; Kauffman, Michael D; Bard, Jaime L; LeJeune, Jeffrey T

    2010-09-01

    Alteration of the gastro-intestinal tract through manipulation of cattle diets has been proposed as a preharvest control measure to reduce fecal shedding of Escherichia coli O157:H7. The objective of this study was to examine the effects of the energy source's moisture content (high moisture corn and dry whole-shelled corn), two natural feed supplements (Saccaromyces cerevisiae boulardii CNCM 1079-Levucell and Aspergillus oryzae-Amaferm), and two levels of vitamin A (2200 IU/kg and no supplementation) on the fecal excretion of E. coli O157:H7 in naturally infected cattle. One hundred sixty-eight Angus-cross beef steers were randomly allocated to 24 pens, and each pen was assigned 1 of 12 dietary treatments in a randomized complete block design. E. coli O157:H7 was detected by rectoanal mucosal swab (RAMS) and fecal grab samples using immunomagnetic separation (IMS) and standard microbiological techniques. On the basis of multivariable multilevel logistic regression models, we found a statistically significant (p < 0.05) increase in the prevalence of E. coli O157:H7 in animals fed dry whole-shelled corn in models based on fecal-IMS, and this effect was increased if a super-shedding animal (shedding > 10(4) colony forming units of E. coli O157:H7 per gram of feces) was present in the pen at the time of testing relative to animals fed high moisture corn and nonexposed to super-shedders. However, in similar models based on RAMS-IMS testing, the effect of corn type on the prevalence of E. coli O157:H7 varied with the type of feed additive used. Being exposed to a super-shedding pen-mate also increased the odds of being positive to E. coli O157:H7 in the RAMS-IMS models. These models demonstrate that the impact of different supplements may vary with the diagnostic test used, and that further research into the biological significance of differences between RAMS- and fecal-IMS test results is warranted.

  7. Procedural knowledge

    SciTech Connect

    Georgeff, M.P.; Lansky, A.L.

    1986-10-01

    Much of commonsense knowledge about the real world is in the form of procedures or sequences of actions for achieving particular goals. In this paper, a formalism is presented for representing such knowledge using the notion of process. A declarative semantics for the representation is given, which allows a user to state facts about the effects of doing things in the problem domain of interest. An operational semantics is also provided, which shows how this knowledge can be used to achieve particular goals or to form intentions regarding their achievement. Given both semantics, our formalism additionally serves as an executable specification language suitable for constructing complex systems. A system based on this formalism is described, and examples involving control of an autonomous robot and fault diagnosis for NASA's space shuttle are provided.

  8. Rotorcraft Diagnostics

    NASA Technical Reports Server (NTRS)

    Haste, Deepak; Azam, Mohammad; Ghoshal, Sudipto; Monte, James

    2012-01-01

    Health management (HM) in any engineering systems requires adequate understanding about the system s functioning; a sufficient amount of monitored data; the capability to extract, analyze, and collate information; and the capability to combine understanding and information for HM-related estimation and decision-making. Rotorcraft systems are, in general, highly complex. Obtaining adequate understanding about functioning of such systems is quite difficult, because of the proprietary (restricted access) nature of their designs and dynamic models. Development of an EIM (exact inverse map) solution for rotorcraft requires a process that can overcome the abovementioned difficulties and maximally utilize monitored information for HM facilitation via employing advanced analytic techniques. The goal was to develop a versatile HM solution for rotorcraft for facilitation of the Condition Based Maintenance Plus (CBM+) capabilities. The effort was geared towards developing analytic and reasoning techniques, and proving the ability to embed the required capabilities on a rotorcraft platform, paving the way for implementing the solution on an aircraft-level system for consolidation and reporting. The solution for rotorcraft can he used offboard or embedded directly onto a rotorcraft system. The envisioned solution utilizes available monitored and archived data for real-time fault detection and identification, failure precursor identification, and offline fault detection and diagnostics, health condition forecasting, optimal guided troubleshooting, and maintenance decision support. A variant of the onboard version is a self-contained hardware and software (HW+SW) package that can be embedded on rotorcraft systems. The HM solution comprises components that gather/ingest data and information, perform information/feature extraction, analyze information in conjunction with the dependency/diagnostic model of the target system, facilitate optimal guided troubleshooting, and offer

  9. FEL-accelerator related diagnostics

    SciTech Connect

    Kevin Jordan; David Douglas; Stephen V. Benson; Pavel Evtuschenko

    2007-08-02

    Free Electron Lasers (FEL) present a unique set of beam parameters to the diagnostics suite. The FEL requires characterization of the full six dimensional phase space of the electron beam at the wiggler and accurate alignment of the electron beam to the optical mode of the laser. In addition to the FEL requirements on the diagnostics suite, the Jefferson Lab FEL is operated as an Energy Recovered Linac (ERL) which imposes additional requirements on the diagnostics. The ERL aspect of the Jefferson Lab FEL requires that diagnostics operate over a unique dynamic range and operate with simultaneous transport of the accelerated and energy recovered beams. This talk will present how these challenges are addressed at the Jefferson Lab FEL.

  10. Diagnostic agreement predicts treatment process and outcomes in youth mental health clinics.

    PubMed

    Jensen-Doss, Amanda; Weisz, John R

    2008-10-01

    Several studies have documented low rates of agreement between clinician- and researcher-generated diagnoses. However, little is known about whether this lack of agreement has implications for the processes and outcomes of subsequent treatment. To study this possibility, the authors used diagnostic agreement to predict therapy engagement and outcomes for 197 youths treated in 5 community mental health clinics. Diagnostic agreement predicted better therapy engagement, with the agree group having fewer therapy no-shows and cancellations and a decreased likelihood of therapy dropout. Additionally, support for a link between agreement and treatment outcomes was found, as the agree group obtained larger reductions in parent-reported internalizing problems during treatment. These findings suggest that diagnostic accuracy may be an important precursor to successful treatment and highlight the importance of future research to find ways to incorporate standardized diagnostic procedures into clinical care settings. PMID:18837589

  11. Diagnostic imaging in internal medicine

    SciTech Connect

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging.

  12. Measures of Diagnostic Accuracy: Basic Definitions

    PubMed Central

    Šimundić, Ana-Maria

    2009-01-01

    Diagnostic accuracy relates to the ability of a test to discriminate between the target condition and health. This discriminative potential can be quantified by the measures of diagnostic accuracy such as sensitivity and specificity, predictive values, likelihood ratios, the area under the ROC curve, Youden's index and diagnostic odds ratio. Different measures of diagnostic accuracy relate to the different aspects of diagnostic procedure: while some measures are used to assess the discriminative property of the test, others are used to assess its predictive ability. Measures of diagnostic accuracy are not fixed indicators of a test performance, some are very sensitive to the disease prevalence, while others to the spectrum and definition of the disease. Furthermore, measures of diagnostic accuracy are extremely sensitive to the design of the study. Studies not meeting strict methodological standards usually over- or under-estimate the indicators of test performance as well as they limit the applicability of the results of the study. STARD initiative was a very important step toward the improvement the quality of reporting of studies of diagnostic accuracy. STARD statement should be included into the Instructions to authors by scientific journals and authors should be encouraged to use the checklist whenever reporting their studies on diagnostic accuracy. Such efforts could make a substantial difference in the quality of reporting of studies of diagnostic accuracy and serve to provide the best possible evidence to the best for the patient care. This brief review outlines some basic definitions and characteristics of the measures of diagnostic accuracy.

  13. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  14. Procedural pediatric dermatology.

    PubMed

    Metz, Brandie J

    2013-04-01

    Due to many factors, including parental anxiety, a child's inability to understand the necessity of a procedure and a child's unwillingness to cooperate, it can be much more challenging to perform dermatologic procedures in children. This article reviews pre-procedural preparation of patients and parents, techniques for minimizing injection-related pain and optimal timing of surgical intervention. The risks and benefits of general anesthesia in the setting of pediatric dermatologic procedures are discussed. Additionally, the surgical approach to a few specific types of birthmarks is addressed.

  15. Phosphazene additives

    DOEpatents

    Harrup, Mason K; Rollins, Harry W

    2013-11-26

    An additive comprising a phosphazene compound that has at least two reactive functional groups and at least one capping functional group bonded to phosphorus atoms of the phosphazene compound. One of the at least two reactive functional groups is configured to react with cellulose and the other of the at least two reactive functional groups is configured to react with a resin, such as an amine resin of a polycarboxylic acid resin. The at least one capping functional group is selected from the group consisting of a short chain ether group, an alkoxy group, or an aryloxy group. Also disclosed are an additive-resin admixture, a method of treating a wood product, and a wood product.

  16. Potlining Additives

    SciTech Connect

    Rudolf Keller

    2004-08-10

    In this project, a concept to improve the performance of aluminum production cells by introducing potlining additives was examined and tested. Boron oxide was added to cathode blocks, and titanium was dissolved in the metal pool; this resulted in the formation of titanium diboride and caused the molten aluminum to wet the carbonaceous cathode surface. Such wetting reportedly leads to operational improvements and extended cell life. In addition, boron oxide suppresses cyanide formation. This final report presents and discusses the results of this project. Substantial economic benefits for the practical implementation of the technology are projected, especially for modern cells with graphitized blocks. For example, with an energy savings of about 5% and an increase in pot life from 1500 to 2500 days, a cost savings of $ 0.023 per pound of aluminum produced is projected for a 200 kA pot.

  17. Additive Manufacturing of Medical Models--Applications in Rhinology.

    PubMed

    Raos, Pero; Klapan, Ivica; Galeta, Tomislav

    2015-09-01

    In the paper we are introducing guidelines and suggestions for use of 3D image processing SW in head pathology diagnostic and procedures for obtaining physical medical model by additive manufacturing/rapid prototyping techniques, bearing in mind the improvement of surgery performance, its maximum security and faster postoperative recovery of patients. This approach has been verified in two case reports. In the treatment we used intelligent classifier-schemes for abnormal patterns using computer-based system for 3D-virtual and endoscopic assistance in rhinology, with appropriate visualization of anatomy and pathology within the nose, paranasal sinuses, and scull base area.

  18. Upgrading Diagnostic Diagrams

    NASA Astrophysics Data System (ADS)

    Proxauf, B.; Kimeswenger, S.; Öttl, S.

    2014-04-01

    Diagnostic diagrams of forbidden lines have been a useful tool for observers in astrophysics for many decades now. They are used to obtain information on the basic physical properties of thin gaseous nebulae. Moreover they are also the initial tool to derive thermodynamic properties of the plasma from observations to get ionization correction factors and thus to obtain proper abundances of the nebulae. Some diagnostic diagrams are in wavelengths domains which were difficult to take either due to missing wavelength coverage or low resolution of older spectrographs. Thus they were hardly used in the past. An upgrade of this useful tool is necessary because most of the diagrams were calculated using only the species involved as a single atom gas, although several are affected by well-known fluorescence mechanisms as well. Additionally the atomic data have improved up to the present time. The new diagnostic diagrams are calculated by using large grids of parameter space in the photoionization code CLOUDY. For a given basic parameter the input radiation field is varied to find the solutions with cooling-heating-equilibrium. Empirical numerical functions are fitted to provide formulas usable in e.g. data reduction pipelines. The resulting diagrams differ significantly from those used up to now and will improve the thermodynamic calculations.

  19. Diagnostics for Developing Countries.

    PubMed

    McNerney, Ruth

    2015-01-01

    Improving the availability of high quality diagnostic tests for infectious diseases is a global priority. Lack of access by people living in low income countries may deprive them of life saving treatment and reduces opportunities to prevent onward transmission and spread of the disease. Diagnostic laboratories are often poorly resourced in developing countries, and sparsely distributed. Improved access may be achieved by using tests that do not require laboratory support, including rapid tests for use at the point-of-care. Despite increased interest, few new in vitro diagnostic (IVD) products reach the majority populations in low income countries. Barriers to uptake include cost and lack of robustness, with reduced test performances due to environmental pressures such as high ambient temperatures or dust. In addition to environmental factors test developers must consider the local epidemiology. Confounding conditions such as immunosuppression or variations in antigen presentation or genotype can affect test performance. Barriers to product development include access to finance to establish manufacturing capacity and cover the costs of market entry for new devices. Costs and delays may be inflated by current regulatory preregistration processes to ensure product safety and quality, and more harmonized approaches are needed.

  20. Diagnostics for Developing Countries.

    PubMed

    McNerney, Ruth

    2015-01-01

    Improving the availability of high quality diagnostic tests for infectious diseases is a global priority. Lack of access by people living in low income countries may deprive them of life saving treatment and reduces opportunities to prevent onward transmission and spread of the disease. Diagnostic laboratories are often poorly resourced in developing countries, and sparsely distributed. Improved access may be achieved by using tests that do not require laboratory support, including rapid tests for use at the point-of-care. Despite increased interest, few new in vitro diagnostic (IVD) products reach the majority populations in low income countries. Barriers to uptake include cost and lack of robustness, with reduced test performances due to environmental pressures such as high ambient temperatures or dust. In addition to environmental factors test developers must consider the local epidemiology. Confounding conditions such as immunosuppression or variations in antigen presentation or genotype can affect test performance. Barriers to product development include access to finance to establish manufacturing capacity and cover the costs of market entry for new devices. Costs and delays may be inflated by current regulatory preregistration processes to ensure product safety and quality, and more harmonized approaches are needed. PMID:26854149

  1. Behavioral diagnostics.

    PubMed

    Bailey, J S; Pyles, D A

    1989-01-01

    The contemporary behavior analyst, to operate ethically and effectively, must be aware of many more factors affecting behavior than simple consequences. Although the literature demonstrating the effectiveness of active behavior management is impressive, a compelling argument can be made that a great number of behavior problem seen in individuals with developmental disabilities may be attributable to factors other than consequences. Our experience has been more often than not that physiological, organic, medication, or situational variables are the actual culprits in maladaptive behavior. Individuals with severe or profound retardation may respond to aversive features of their environment by displaying noncompliance, tantrums, aggression, or self-injurious behavior. These antecedents can affect their behavior just as powerfully as can the consequences of their behavior. Behavior analysts must become sensitive to these potential factors and be prepared to employ behavioral diagnostic strategies in the search for the causes of maladaptive behavior. Finally, they must be prepared to design rather unconventional passive behavior management treatment programs involving the manipulation of the antecedent environment. In the case of Carrie, from the example at the beginning of this paper, the analysis yielded the hypothesis that her face scratching was a reaction to sinus blockage caused by seasonal allergies. Her treatment involved daily dosages of antihistamines administered by our nurses and subsequent elimination of the scratching. Tom was found to be suffering from "wheelchair fatigue." When he was allowed to recline on other surfaces (e.g., bean bag chair, mat, bolster) on a regular basis, he did not attempt any form of self-injury. Melissa was found to have a severe case of Pre Menstrual Syndrome as well as seizure disorder, and was treated with the appropriate medications. Her headbanging was reduced to a few minor incidents per month. Walter's tantrums on closer

  2. Salivary biomarkers: toward future clinical and diagnostic utilities.

    PubMed

    Yoshizawa, Janice M; Schafer, Christopher A; Schafer, Jason J; Farrell, James J; Paster, Bruce J; Wong, David T W

    2013-10-01

    The pursuit of timely, cost-effective, accurate, and noninvasive diagnostic methodologies is an endeavor of urgency among clinicians and scientists alike. Detecting pathologies at their earliest stages can significantly affect patient discomfort, prognosis, therapeutic intervention, survival rates, and recurrence. Diagnosis and monitoring often require painful invasive procedures such as biopsies and repeated blood draws, adding undue stress to an already unpleasant experience. The discovery of saliva-based microbial, immunologic, and molecular biomarkers offers unique opportunities to bypass these measures by utilizing oral fluids to evaluate the condition of both healthy and diseased individuals. Here we discuss saliva and its significance as a source of indicators for local, systemic, and infectious disorders. We highlight contemporary innovations and explore recent discoveries that deem saliva a mediator of the body's physiological condition. Additionally, we examine the current state of salivary diagnostics and its associated technologies, future aspirations, and potential as the preferred route of disease detection, monitoring, and prognosis. PMID:24092855

  3. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  4. Tomographic diagnostics of nonthermal plasmas

    NASA Astrophysics Data System (ADS)

    Denisova, Natalia

    2009-10-01

    In the previous work [1], we discussed a ``technology'' of tomographic method and relations between the tomographic diagnostics in thermal (equilibrium) and nonthermal (nonequilibrium) plasma sources. The conclusion has been made that tomographic reconstruction in thermal plasma sources is the standard procedure at present, which can provide much useful information on the plasma structure and its evolution in time, while the tomographic reconstruction of nonthermal plasma has a great potential at making a contribution to understanding the fundamental problem of substance behavior in strongly nonequilibrium conditions. Using medical terminology, one could say, that tomographic diagnostics of the equilibrium plasma sources studies their ``anatomic'' structure, while reconstruction of the nonequilibrium plasma is similar to the ``physiological'' examination: it is directed to study the physical mechanisms and processes. The present work is focused on nonthermal plasma research. The tomographic diagnostics is directed to study spatial structures formed in the gas discharge plasmas under the influence of electrical and gravitational fields. The ways of plasma ``self-organization'' in changing and extreme conditions are analyzed. The analysis has been made using some examples from our practical tomographic diagnostics of nonthermal plasma sources, such as low-pressure capacitive and inductive discharges. [0pt] [1] Denisova N. Plasma diagnostics using computed tomography method // IEEE Trans. Plasma Sci. 2009 37 4 502.

  5. The optimal diagnostic workup for children with suspected food allergy.

    PubMed

    Berni Canani, Roberto; Di Costanzo, Mara; Troncone, Riccardo

    2011-10-01

    Food allergy is defined as an abnormal immunologic reaction to food proteins that causes an adverse clinical reaction. In addition to well-known acute allergic reactions and anaphylaxis triggered by immunoglobulin E antibody-mediated immune responses to food proteins, there is an increasing recognition of cell-mediated disorders such as eosinophilic esophagitis and food protein-induced enterocolitis syndrome. More than 90% of food allergies in childhood are caused by eight foods: cow's milk, hen's egg, soy, peanuts, tree nuts, wheat, fish, and shellfish. The diagnostic workup for a child with suspected food allergy includes a detailed medical history, physical examination, food allergy screening tests, and responses to an elimination diet and an oral food challenge. None of the screening tests, alone or in combination, can definitely diagnose or exclude a food allergy. Novel diagnostic methods including those that focus on immune responses to specific food proteins or epitopes of specific proteins are under active study. Unconventional diagnostic methods are increasingly used, but they lack scientific rationale, standardization, and reproducibility. In selected cases, such as eosinophilic esophageal gastroenteropathies or food protein-induced gastroesophageal reflux disease, invasive procedures are mandatory for an accurate diagnosis. Properly done, an oral food challenge is still the gold standard in the diagnostic workup. An incorrect diagnosis is likely to result in unnecessary dietary restrictions, which, if prolonged, may adversely affect the child's nutritional status and growth.

  6. Elevation of neuron specific enolase and brain iron deposition on susceptibility-weighted imaging as diagnostic clues for beta-propeller protein-associated neurodegeneration in early childhood: Additional case report and review of the literature.

    PubMed

    Takano, Kyoko; Shiba, Naoko; Wakui, Keiko; Yamaguchi, Tomomi; Aida, Noriko; Inaba, Yuji; Fukushima, Yoshimitsu; Kosho, Tomoki

    2016-02-01

    Beta-propeller protein-associated neurodegeneration (BPAN), also known as static encephalopathy of childhood with neurodegeneration in adulthood (SENDA), is a subtype of neurodegeneration with brain iron accumulation (NBIA). BPAN is caused by mutations in an X-linked gene WDR45 that is involved in autophagy. BPAN is characterized by developmental delay or intellectual disability until adolescence or early adulthood, followed by severe dystonia, parkinsonism, and progressive dementia. Brain magnetic resonance imaging (MRI) shows iron deposition in the bilateral globus pallidus (GP) and substantia nigra (SN). Clinical manifestations and laboratory findings in early childhood are limited. We report a 3-year-old girl with BPAN who presented with severe developmental delay and characteristic facial features. In addition to chronic elevation of serum aspartate transaminase, lactate dehydrogenase, creatine kinase, and soluble interleukin-2 receptor, she had persistent elevation of neuron specific enolase (NSE) in serum and cerebrospinal fluid. MRI using susceptibility-weighted imaging (SWI) demonstrated iron accumulation in the GP and SN bilaterally. Targeted next-generation sequencing identified a de novo splice-site mutation, c.831-1G>C in WDR45, which resulted in aberrant splicing evidenced by reverse transcriptase-PCR. Persistent elevation of NSE and iron deposition on SWI may provide clues for diagnosis of BPAN in early childhood.

  7. SDQ: discriminative validity and diagnostic potential

    PubMed Central

    Silva, Thaysa B. F.; Osório, Flávia L.; Loureiro, Sonia R.

    2015-01-01

    The Strengths and Difficulties Questionnaire (SDQ) was designed to screen for behavioral problems in youths based on cutoff points that favor the instrument's diagnostic sensitivity. The present study aimed to analyze the discriminative validity of the SDQ to identify behavioral difficulties and prosocial resources in school-age children compared with the diagnostic data collected by the corresponding sections of the Development and Well-being Assessment (DAWBA). In addition, new cutoff points that value specificity were defined for the SDQ scales, exploring its diagnostic potential. This study was conducted in Brazil and assessed a community convenience sample that consisted of 120 children aged 6–12 years who were not under psychological/psychiatric treatment. The mothers of the participants also completed a sociodemographic questionnaire. Descriptive statistics were used to clinically characterize the sample. A ROC curve was used to assess the discriminant validity of the SDQ, and new cutoff points were established to maximize the instrument's specificity. The new cutoff points enabled a significant increase in specificity without a significant loss of sensitivity, which favors approaches based on measures of screening and diagnosis yet does not damage the instrument's screening capacity. The following increases were observed: 100% for the depressive disorder scale (cutoff point = 7), 95.1% for the generalized anxiety disorder scale (cutoff point = 7), 46.6% for the conduct disorder scale (cutoff point = 6), 19.2% for the hyperactive disorder scale (cutoff point = 8), and 27.6% for the antisocial personality disorder scale (cutoff point = 6). A cutoff point of 8 was applied to the prosocial behavior scale, which exhibited a 62.1% increase in specificity. The use of more specific cutoff points generated more accurate results and favored SDQ's use, particularly in contexts of care that require more precise and faster procedures for identification of problems

  8. Nuclear Diagnostics of ICF

    SciTech Connect

    Izumi, N; Ierche, R A; Moran, M J; Phillips, T W; Sangster, T C; Schmid, G J; Stoyer, M A; Disdier, L; Bourgade, J L; Rouyer, A; Fisher, R K; Gerggren, R R; Caldwen, S E; Faulkner, J R; Mack, J M; Oertel, J A; Young, C S; Glebov, V Y; Jaanimagi, P A; Meyerhofer, D D; Soures, J M; Stockel, C; Frenje, J A; Li, C K; Petrasso, R D

    2001-10-18

    , a spatial resolution of {approx} 5 {micro}m is required for imaging systems. Fourth, the diagnostics operate in a harsh background. In implosion experiments, strong bursts of electromagnetic pulses, x-rays, neutrons, and neutron-induced radioactivity are produced. Therefore the diagnostics have to be designed to survive in these backgrounds. In addition, to prevent materials ablated from diagnostic components close to the target from being deposited on the laser optics, these components are excluded from a zone around the target with a radius in the range of 0.5 m to 5 m. This exclusion zone has a large impact on diagnostic design.

  9. Far infrared fusion plasma diagnostics

    SciTech Connect

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-01-01

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer's importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA's CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  10. Beam diagnostics

    SciTech Connect

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-08-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the {open_quotes}Booster{close_quotes} and {open_quotes}ATLAS{close_quotes} linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates.

  11. [Endosonographic diagnostics of hepatobiliary and pancreatic diseases].

    PubMed

    Starkov, Iu G; Solodinina, E N; Shishin, K V; Plotnikova, A S; Kobesova, T A; Dubova, E A

    2009-01-01

    Clinical use of endoscopic ultrasound (EUS) diagnostics of 550 patients with diseases of hepatobiliary and pancreas was analyzed. The procedure of the examination was thoroughly described. Ultrasound semiotics of the pancreas, papilla Vateri and bile ducts' lesions was defined. Accuracy of EUS in the diagnostics of solid pancreas tumors was 81,6%. Accuracy of the method in the diagnostics of the vessel invasion was 81,6%. EUS was considered to be leading in the diagnostics of papilla Vateri and duodenal tumors, its accuracy was up to 97,2%, which is much higher then other radiological and endoscopic methods. EUS was highly effective in diagnostics of choledocholithiasis and comprised 90,2%. The introduction of thin-needle biopsy, Doppler mapping and elastography in the EUS protocol permitted further increase of the accuracy and value of the method for the surgical practice.

  12. Nucleic acid probes in diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Oberry, Phillip A.

    1991-01-01

    The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

  13. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  14. Optical Diagnostics in Medicine

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor

    2003-03-01

    Light has a unique potential for non-invasive tissue diagnosis. The relatively short wavelength of light allows imaging of tissue at the resolution of histopathology. While strong multiple scattering of light in tissue makes attainment of this resolution difficult for thick tissues, most pathology emanates from epithelial surfaces. Therefore, high-resolution diagnosis of many important diseases may be achieved by transmitting light to the surface of interest. The recent fiber-optic implementation of technologies that reject multiple scattering, such as confocal microscopy and optical low coherence interferometry, have brought us one step closer to realizing non-invasive imaging of architectural and cellular features of tissue. Optical coherence tomography (OCT) can produce high-resolution cross-sectional images of biological structures. Clinical OCT studies conducted in the gastrointestinal tract and cardiovascular system have shown that OCT is capable of providing images of the architectural (> 20 µm) microanatomy of a variety of epithelial tissues, including the layered structure of squamous epithelium and arterial vessels. Fine Needle Aspiration- Low Coherence Interferometry (FNA-LCI) is another optical diagnostics technique, which is a suitable solution to increase the effectiveness of the FNA procedures. LCI is capable of measuring depth resolved (axial, z) tissue structure, birefringence, flow (Doppler shift), and spectra at a resolution of several microns. Since LCI systems are fiber-optic based, LCI probes may easily fit within the bore of a fine gauge needle, allowing diagnostic information to be obtained directly from the FNA biopsy site. Fiber optic spectrally encoded confocal microscopy (SECM) is a new confocal microscopy method, which eliminates the need for rapid beam scanning within the optical probe. This advance enables confocal microscopy to be performed through small diameter probes and will allow assessment of internal human tissues in vivo at

  15. New Diagnostics for Childhood Tuberculosis.

    PubMed

    Chiang, Silvia S; Swanson, Douglas S; Starke, Jeffrey R

    2015-09-01

    The challenge of diagnosing childhood tuberculosis (TB) results from its paucibacillary nature and the difficulties of sputum collection in children. Mycobacterial culture, the diagnostic gold standard, provides microbiological confirmation in only 30% to 40% of childhood pulmonary TB cases and takes up to 6 weeks to result. Conventional drug susceptibility testing requires an additional 2 to 4 weeks after culture confirmation. In response to the low sensitivity and long wait time of the traditional diagnostic approach, many new assays have been developed. These new tools have shortened time to result; however, none of them offer greater sensitivity than culture.

  16. Kindergarten Screening Procedures: Early Identification or Merely Early Labeling?

    ERIC Educational Resources Information Center

    Hillerich, Robert L.

    Concern about typical early identification procedures used with kindergarten children to predict potential reading failure is expressed in this paper. A diagnostic procedure for screening kindergarten children and then prescribing an individualized program for each child is described. The screening battery--Prediction with Diagnostic Qualities…

  17. Surgical Procedures. Second Edition. Teacher Edition.

    ERIC Educational Resources Information Center

    Baker, Beverly; And Others

    This teacher's guide contains 13 units of instruction for a course that will prepare students with the entry-level competencies needed by a surgical technologist. The course covers the following topics: introduction to surgical procedures; diagnostic procedures; general surgery; gastrointestinal surgery; obstetrics and gynecological surgery;…

  18. Advanced diagnostic methods in avionics

    NASA Astrophysics Data System (ADS)

    Popyack, Leonard Joseph, Jr.

    Advanced diagnostic systems facilitate further enhancement of reliability and safety of modern aircraft. Unlike classical reliability analyses, addressing specific classes of systems or devices, this research is aimed at the development of methods for assessment of the individual reliability characteristics of particular system components subjected to their unique histories of operational conditions and exposure to adverse environmental factors. Individual reliability characteristics are crucial for the implementation of the most efficient maintenance practice of flight-critical system components, known as "condition-based maintenance." The dissertation presents hardware and software aspects of a computer-based system, Time-Stress Monitoring Device, developed to record, store, and analyze raw data characterizing operational and environmental conditions and performance of electro-mechanical flight control system components and aircraft electronics (avionics). Availability of this data facilitates formulation and solution of such diagnostic problems as estimation of the probability of failure and life expectancy of particular components, failure detection, identification, and prediction. Statistical aspects of system diagnostics are considered. Particular diagnostic procedures utilizing cluster analysis, Bayes' technique, and regression analysis are formulated. Laboratory and simulation experiment that verify the obtained results are provided.

  19. Molecular diagnostics in tuberculosis.

    PubMed

    Cheng, V C C; Yew, W W; Yuen, K Y

    2005-11-01

    Molecular diagnostics in tuberculosis has enabled rapid detection of Mycobacterium tuberculosis complex in clinical specimens, identification of mycobacterial species, detection of drug resistance, and typing for epidemiological investigation. In the laboratory diagnosis of tuberculosis, the nucleic acid amplification (NAA) test is rapid and specific but not as sensitive as culture of mycobacteria. The primary determinant of successful NAA testing for tuberculosis depends on the shedding of mycobacterial DNA in secretions from caseating granulomas and its dissemination into sterile body fluids or tissue biopsies. In multibacillary diseases with a high mycobacterial load, a positive Ziehl-Neelsen smear with a positive NAA test is diagnostic of active tuberculosis, whereas a positive Ziehl-Neelsen smear with a negative NAA test in the absence of inhibitors would indicate nontuberculous mycobacterial disease. The role of the NAA test is more important in paucibacillary diseases with low mycobacterial loads. The presence of polymerase chain reaction (PCR) inhibitors, however, especially in extrapulmonary specimens, may produce false-negative results. Although this problem can be overcome to some extent by extra extraction steps, the additional processing invariably leads to the loss of mycobacterial DNA. To circumvent this problem, a brief culture augmentation step is carried out before the NAA test is performed, which can enhance the mycobacterial load while concomitantly diluting inhibitors, thereby maintaining the sensitivity of the test without excessively increasing turnaround time.

  20. [INITIAL RESULTS OF DIAGNOSTIC APPLICATION OF ENDOBRONCHIAL ULTRASOUND IN CLINICAL HOSPITAL DUBRAVA].

    PubMed

    Zivković, Nevenka Piskac; Ostović, Karmen Trutin; Bosnjak, Danica; Tudorić, Neven

    2016-01-01

    Endobronchial ultrasound (EBUS) enables visualization of mediastinal and hilar lymph nodes as well as, in case of clinical indication, its transbronchial needle aspiration (TBNA). Simultaneous application of color doppler gives the additional prospects to investigate the blood vessels. The primary indication for EBUS is radiographic finding of mediastinal and/or hilar lymph nodes enlargement as well as the staging of non-small cell lung cancer (NSCLC). In this article we present the initial results of application of this valuable diagnostic procedure performed at the Department for pulmonary diseases in Clinical hospital Dubrava in Zagreb. According to its high sensitivity and specificity, and being safe and well tolerated, EBUS-TBNA was positioned as basic diagnostic procedure in patients with mediastinal lymphadenopathy. PMID:27290812

  1. Dental Procedures.

    PubMed

    Ramponi, Denise R

    2016-01-01

    Dental problems are a common complaint in emergency departments in the United States. There are a wide variety of dental issues addressed in emergency department visits such as dental caries, loose teeth, dental trauma, gingival infections, and dry socket syndrome. Review of the most common dental blocks and dental procedures will allow the practitioner the opportunity to make the patient more comfortable and reduce the amount of analgesia the patient will need upon discharge. Familiarity with the dental equipment, tooth, and mouth anatomy will help prepare the practitioner for to perform these dental procedures. PMID:27482994

  2. [Diagnostic protocol and special tests].

    PubMed

    Bellia, M; Pennarola, R

    2008-01-01

    Diagnostic protocol and special tests to ionizing radiations have a preventive function in the medical surveillance of the exposed worker. This protocol must be provided with laboratory and special test assessing fitness for working at the risk of ionizing radiations. The health of workers must be compatible with working conditions and radiation risk. This healthiness of workers is evalued in the time to give an assessment fitness for working at ionizing radiations. For this purpose the basic diagnostic protocol must guarantee minimum information about state of organs and apparatus in addition to the normality of the metabolisms. The diagnostic protocol of the exposed worker to ionizing radiations must be adapted to the specific clinical situation so as to finally make a costs-benefits balance sheet. PMID:19288808

  3. Balloon gondola diagnostics package

    NASA Technical Reports Server (NTRS)

    Cantor, K. M.

    1986-01-01

    In order to define a new gondola structural specification and to quantify the balloon termination environment, NASA developed a balloon gondola diagnostics package (GDP). This addition to the balloon flight train is comprised of a large array of electronic sensors employed to define the forces and accelerations imposed on a gondola during the termination event. These sensors include the following: a load cell, a three-axis accelerometer, two three-axis rate gyros, two magnetometers, and a two axis inclinometer. A transceiver couple allows the data to be telemetered across any in-line rotator to the gondola-mounted memory system. The GDP is commanded 'ON' just prior to parachute deployment in order to record the entire event.

  4. A diagnostic wax-up technique.

    PubMed

    Morgan, D W; Comella, M C; Staffanou, R S

    1975-02-01

    A procedural outline has been presented for the accomplishment of a diagnostic wax-up as a preliminary step to actual preparation of the teeth as suggested by the proponents of gnathologic techniques. 8.9) The use of this technique will decrease the possibility of error in the construction of any extensive fixed partial denture prosthesis. The success of any procedure required the willingness of general dentists and specialists to, 'Spend more time planning than doing.'

  5. Total cholesterol performance of Abell–Levy–Brodie–Kendall reference measurement procedure: Certification of Japanese in-vitro diagnostic assay manufacturers through CDC’s Cholesterol Reference Method Laboratory Network☆

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Kiyama, Masahiko; Yokoyama, Shinji; Kayamori, Yuzo; Koyama, Isao; Nishimura, Kunihiro; Nakai, Michikazu; Dasti, Mahnaz; Vesper, Hubert W.; Teramoto, Tamio; Miyamoto, Yoshihiro

    2015-01-01

    Background Accurate measurement of total cholesterol (TC) is important for cardiovascular disease risk management. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform Abell–Levy–Brodie–Kendall (AK) reference measurement procedure (RMP) for TC as a secondary reference method, and implement Certification Protocol for Manufacturers. Japanese CRMLN laboratory at Osaka performed the AK RMP for 22 years, and conducted TC certification for reagent/calibrator/instrument systems of six Japanese manufacturers every 2 years for 16 years. Osaka TC performance was examined and compared to CDC’s reference values. Methods AK RMP involved sample hydrolysis, cholesterol extraction, and determination of cholesterol levels by spectrophotometry. The Certification Protocol for Manufacturers includes comparison with AK RMP using at least 40 fresh specimens. Demonstration of average bias ≤3% and total coefficient of variation ≤3% qualified an analytical system for certification. Results In the AK RMP used in the Osaka CRMLN laboratory, the regression equation for measuring TC was y (Osaka) = 1.000x (CDC) + 0.032 (n = 619, R2 = 1.000). Six Japanese manufacturers had allowable performance for certification. Conclusions The AK RMP for TC measurement was accurate, precise, and stable for 22 years. Six Japanese manufacturers were certified for 16 years. PMID:25818239

  6. 20 CFR 802.215 - Additional briefs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Additional briefs. 802.215 Section 802.215 Employees' Benefits BENEFITS REVIEW BOARD, DEPARTMENT OF LABOR RULES OF PRACTICE AND PROCEDURE Prereview Procedures Initial Processing § 802.215 Additional briefs. Additional briefs may be filed or ordered in...

  7. Diagnostics for ITER

    SciTech Connect

    Donne, A. J. H.; Hellermann, M. G. von; Barnsley, R.

    2008-10-22

    After an introduction into the specific challenges in the field of diagnostics for ITER (specifically high level of nuclear radiation, long pulses, high fluxes of particles to plasma facing components, need for reliability and robustness), an overview will be given of the spectroscopic diagnostics foreseen for ITER. The paper will describe both active neutral-beam based diagnostics as well as passive spectroscopic diagnostics operating in the visible, ultra-violet and x-ray spectral regions.

  8. Short Nuss bar procedure

    PubMed Central

    2016-01-01

    The Nuss procedure is now the preferred operation for surgical correction of pectus excavatum (PE). It is a minimally invasive technique, whereby one to three curved metal bars are inserted behind the sternum in order to push it into a normal position. The bars are left in situ for three years and then removed. This procedure significantly improves quality of life and, in most cases, also improves cardiac performance. Previously, the modified Ravitch procedure was used with resection of cartilage and the use of posterior support. This article details the new modified Nuss procedure, which requires the use of shorter bars than specified by the original technique. This technique facilitates the operation as the bar may be guided manually through the chest wall and no additional stabilizing sutures are necessary. PMID:27747185

  9. Intelligent diagnostics systems

    NASA Technical Reports Server (NTRS)

    Mcquiston, Barbara M.; Dehoff, Ronald L.

    1992-01-01

    Intelligent systems have been applied to today's problems and could also be applied to space operations integrity. One of these systems is the XMAN tool designed for 'troubleshooting' jet engines. XMAN is the eXpert MAiNtenance tool developed to be an expert information analysis tool which stores trending and diagnostic data on Air Force engines. XMAN operates with a 'network topology' which follows a flow chart containing engine management information reports required by the governments technical order procedures. With XMAN technology, the user is able to identify engine problems by presenting the assertions of the fault isolation logic and attempting to satisfy individual assertions by referring to the databases created by an engine monitoring system. The troubleshooting process requires interaction between the technician and the computer to acquire new evidence form auxiliary maintenance tests corroboration of analytical results to accurately diagnose equipment malfunctions. This same technology will be required for systems which are functioning in space either with an onboard crew, or with an unmanned system. The technology and lessons learned developing this technology while suggesting definite applications for its use with developing space systems are addressed.

  10. DIM and diagnostic placement for NIF experiments

    SciTech Connect

    Kalantar, D

    1999-09-14

    The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition.

  11. Numerical Boundary Condition Procedures

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Topics include numerical procedures for treating inflow and outflow boundaries, steady and unsteady discontinuous surfaces, far field boundaries, and multiblock grids. In addition, the effects of numerical boundary approximations on stability, accuracy, and convergence rate of the numerical solution are discussed.

  12. Interventional procedures in the chest.

    PubMed

    Vollmer Torrubiano, I; Sánchez González, M

    2016-05-01

    Many thoracic conditions will require an interventional procedure for diagnosis and/or treatment. For this reason, radiologists need to know the indications and the technique for each procedure. In this article, we review the various interventional procedures that radiologists should know and the indications for each procedure. We place special emphasis on the potential differences in the diagnostic results and complications between fine-needle aspiration and biopsy. We also discuss the indications for radiofrequency ablation of lung tumors and review the concepts related to the drainage of pulmonary abscesses. We devote special attention to the management of pleural effusion, covering the indications for thoracocentesis and when to use imaging guidance, and to the protocol for pleural drainage. We also discuss the indications for percutaneous treatment of pericardial effusion and the possible complications of this treatment. Finally, we discuss the interventional management of mediastinal lesions and provide practical advice about how to approach these lesions to avoid serious complications.

  13. Some results of multiwave in situ autofluorescence diagnostics

    NASA Astrophysics Data System (ADS)

    Tchernyi, V. V.; Rogatkin, D. A.; Bychenkov, O. A.; Polyakov, P. Y.

    2005-04-01

    The laser "in vivo" autofluorescence diagnostics is now widely studied and applied in different areas of medicine, such as an oncology, dermatology, etc. Recently we have reported of created new professional multiwave laser diagnostic system (MLDS) for this purpose under the international scientific research and development project #1001 supported by the International Scientific and Technology Center. This presentation lights some results of application of the MLDS in a real clinical practice at Moscow Regional Research and Clinical Institute "MONIKI", Department of Radiology. With the use of MLDS we investigated a skin and oral cavity cancer endogenous fluorescence before, during and after standard radiotherapy treatment. A statistical analysis showed that the best radiotherapy result was achieved for the patients with a small initial porfirines" autofluorescence and a great initial flavines" one from irradiated tumor tissues. It was shown that each radiotherapy procedure has an influence on a tissues" autofluorescence intensity. The tendencies in porfirines" fluorescence during a treatment course can be an additional prognostic factor for the prediction of the efficacy of a radiotherapy treatment. Moreover, it was estimated that a number of non-cancerous skin disease has a typical "cancer" initial autofluorescence, that makes it difficult to distinguish them one from another with the use of only the fluorescence diagnostics, but opens the way to investigate the non-cancerous tissues diseases with the help of tissues endogenous fluorescence phenomenon.

  14. 38 CFR 4.27 - Use of diagnostic code numbers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... residual condition is encountered, requiring rating by analogy, the diagnostic code number will be “built... conditions. This procedure will facilitate a close check of new and unlisted conditions, rated by analogy....

  15. 38 CFR 4.27 - Use of diagnostic code numbers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... residual condition is encountered, requiring rating by analogy, the diagnostic code number will be “built... conditions. This procedure will facilitate a close check of new and unlisted conditions, rated by analogy....

  16. The Slow Learner in Mathematics: Diagnostic-Prescriptive Teaching

    ERIC Educational Resources Information Center

    Glennon, Vincent J.; Wilson, John W.

    1973-01-01

    A content taxonomy for elementary school mathematics is presented. Some group and individualized procedures for diagnostic-prescriptive teaching are suggested. Sample lessons from a case study are presented based on the previously presented sections. (LS)

  17. Biosafety principles and practices for the veterinary diagnostic laboratory.

    PubMed

    Kozlovac, Joseph; Schmitt, Beverly

    2015-01-01

    Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques. PMID:25399086

  18. A Construct Validation of the Administrative Diagnostic Inventory.

    ERIC Educational Resources Information Center

    Creighton, Theodore B.

    In November 1996, the National Association of Elementary School Principals (NAESP) approved the revision of the Administrative Diagnostic Inventory (ADI), the diagnostic procedure conducted in their assessment center. To assist the NAESP in the use of the ADI for the assessment of current and prospective school principals, the construct validity…

  19. Oral vs. salivary diagnostics

    NASA Astrophysics Data System (ADS)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  20. [Radionuclide therapy and diagnostics in urology].

    PubMed

    Fendler, W P; Wenter, V; Stief, C G; Gratzke, C; Bartenstein, P

    2015-07-01

    In recent years there has been methodological improvement in established nuclear medicine procedures, such as renal and skeletal scintigraphy and new very specific probes for treatment and diagnosis of urological diseases have been introduced into the clinical routine. New diagnostic methods, such as positron emission tomography (PET) using prostate-specific membrane antigen (PSMA) ligands for highly accurate tumor localization in recurrent prostate cancer have become available in many centers. The very high and selective accumulation of these PSMA ligands in tumor tissue has shown promising therapeutic results. Moreover, since 2013 a new radiopharmaceutical agent, radium-223 dichloride, has been approved for treatment of symptomatic bone metastases of prostate cancer. Better knowledge of indications, benefits and limitations of these procedures will help clinicians to adequately introduce them into patient management. This article summarizes the state of the art in established nuclear medicine procedures for urological disorders and also reports on new diagnostic and therapeutic possibilities.

  1. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  2. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  3. DIAGNOSTIC METHODS IN AYURVEDA

    PubMed Central

    Thakar, V. J.

    1982-01-01

    This is an analytical study of the Diagnostic methods Prescribes in Ayurveda. As in the case of disease and treatments the concept of diagnosis also is unique in Ayurveda. It goes to the Nidana of Doshicimbalance by studying the physical, physiological, psychic and behavoural aspects of the patient. The paper gives an insight into the various diagnostic methods enunciated in Sastras which turns out to be a fore-runner of any of modern diagnostic methods. PMID:22556480

  4. Plasma diagnostics for FED

    SciTech Connect

    Nelson, W.D.

    1981-01-01

    An overview of the plasma diagnostic instruments recommended for the Fusion Engineering Device (FED) is described. First the role and need for plasma diagnostics is discussed. This is followed by an identification of particles and radiation eminating from the plasma. Next some design considerations are presented for the overall set of diagnostic instruments. Finally, instruments used for control and for plasma performance measurements are included in separate lists.

  5. Diagnostic Development on NSTX

    SciTech Connect

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-12-16

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted.

  6. TFTR diagnostic vacuum controller

    SciTech Connect

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  7. A laser-spectroscopy complex for fluorescent diagnostics and photodynamic therapy of age-related macula degeneration

    NASA Astrophysics Data System (ADS)

    Shevchik, S. A.; Meerovich, Gennadii A.; Budzinskaya, M. V.; Ermakova, N. A.; Kharnas, Sergey S.; Loschenov, Victor B.

    2004-06-01

    A laser-spectroscopy complex was developed for fluorescent diagnostics and photodynamic therapy of age related macula degeneration using the Russian photosensitizer Photosense. The complex is based on slit lamp which was additionally equipped with an optical adapter, and the video adapter allows to combine the procedure of photodynamic therapy and the control of its carrying in the frame work of one procedure. The sensitivity and spatial resolution of the complex were investigated using a special test object. The availability of the developed complex and Photosense itself was examined on experimental animals.

  8. [Diagnostic Errors in Medicine].

    PubMed

    Buser, Claudia; Bankova, Andriyana

    2015-12-01

    The recognition of diagnostic errors in everyday practice can help improve patient safety. The most common diagnostic errors are the cognitive errors, followed by system-related errors and no fault errors. The cognitive errors often result from mental shortcuts, known as heuristics. The rate of cognitive errors can be reduced by a better understanding of heuristics and the use of checklists. The autopsy as a retrospective quality assessment of clinical diagnosis has a crucial role in learning from diagnostic errors. Diagnostic errors occur more often in primary care in comparison to hospital settings. On the other hand, the inpatient errors are more severe than the outpatient errors.

  9. [Diagnostic Errors in Medicine].

    PubMed

    Buser, Claudia; Bankova, Andriyana

    2015-12-01

    The recognition of diagnostic errors in everyday practice can help improve patient safety. The most common diagnostic errors are the cognitive errors, followed by system-related errors and no fault errors. The cognitive errors often result from mental shortcuts, known as heuristics. The rate of cognitive errors can be reduced by a better understanding of heuristics and the use of checklists. The autopsy as a retrospective quality assessment of clinical diagnosis has a crucial role in learning from diagnostic errors. Diagnostic errors occur more often in primary care in comparison to hospital settings. On the other hand, the inpatient errors are more severe than the outpatient errors. PMID:26649954

  10. BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

    SciTech Connect

    R. C. York; X. Wu; Q. Zhao

    2011-12-21

    End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

  11. Optimal sampling ratios in comparative diagnostic trials

    PubMed Central

    Dong, Ting; Tang, Liansheng Larry; Rosenberger, William F.

    2014-01-01

    Summary A subjective sampling ratio between the case and the control groups is not always an efficient choice to maximize the power or to minimize the total required sample size in comparative diagnostic trials.We derive explicit expressions for an optimal sampling ratio based on a common variance structure shared by several existing summary statistics of the receiver operating characteristic curve. We propose a two-stage procedure to estimate adaptively the optimal ratio without pilot data. We investigate the properties of the proposed method through theoretical proofs, extensive simulation studies and a real example in cancer diagnostic studies. PMID:24948841

  12. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  13. TFTR diagnostic control and data acquisition system

    SciTech Connect

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  14. What is the diagnostic value of repeating a nondiagnostic video-EEG study?

    PubMed

    Elgavish, Rotem A; Cabaniss, Wyman W

    2011-06-01

    Repeat video-EEG (VEEG) may increase diagnostic yield, but the test is resource intensive, time-consuming, and expensive and poses some potential risks to patients. It is also relatively common to monitor a patient for several days without capturing any clinical events. The purpose of this study was to determine the diagnostic value of repeat admissions for VEEG and to determine if the commonly available clinical information could predict the diagnostic outcome, "diagnostic" or "nondiagnostic," of a repeat study. A study was deemed diagnostic if the admission resulted in a definitive diagnosis of the patient's typical events. The authors retrospectively reviewed the charts of 3,727 patients completing scalp VEEG at the University of Alabama at Birmingham Epilepsy Center from 2002 to 2009. Minors, mentally retarded patients, and patients readmitted for surgical procedures or presurgical localization were excluded. Single and multiple regressions were used to determine if any of the parameters could predict the diagnostic outcome of a repeat VEEG study. Only younger age was independently predictive of a diagnostic readmission (P < 0.05), while longer total duration of monitoring was suggestive (P = 0.07). A repeat VEEG study was useful in 55.2% of patients, most of whom were diagnosed after only 1 additional admission. In the patient population studied, 82.4% were diagnosed on the first admission (2,622 of 3,183), 52.9% on the second (46 of 87), and 40% on the third (2 of 5). Repeat VEEG admissions are useful, and clinical expertise may be the best tool for planning potential readmissions.

  15. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Guidance 1. When the DISCO cannot affirmatively find that it is clearly consistent with the national... processing the case, deny issuance of the requested security clearance, and direct the DISCO to revoke any... of the SOR and transmittal to the Director for notification of the DISCO for appropriate action....

  16. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... request a hearing. It shall also explain the adverse consequences for failure to respond to the SOR within... answer is insufficient. To be entitled to a hearing, the applicant must specifically request a hearing in.... If the applicant has not requested a hearing with his or her answer to the SOR and Department...

  17. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Official records or evidence compiled or created in the regular course of business, other than DoD... who has been engaged in obtaining intelligence information for the Government and that disclosure...

  18. Target Diagnostics Supports NIF's Path to Ignition

    SciTech Connect

    Shelton, R

    2011-12-07

    the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

  19. Automotive Diagnostic Technologies.

    ERIC Educational Resources Information Center

    Columbus State Community Coll., OH.

    This document contains materials developed for and about the automotive diagnostic technologies tech prep program of the South-Western City Schools in Ohio. Part 1 begins with a map of the program, which begins with an automotive/diagnostic technologies program in grades 11 and 12 that leads to entry-level employment or a 2-year automotive…

  20. Huntington Disease: Molecular Diagnostics Approach.

    PubMed

    Bastepe, Murat; Xin, Winnie

    2015-10-06

    Huntington disease (HD) is caused by expansion of a CAG trinucleotide repeat in the first exon of the Huntingtin (HTT) gene. Molecular testing of Huntington disease for diagnostic confirmation and disease prediction requires detection of the CAG repeat expansion. There are three main types of HD genetic testing: (1) diagnostic testing to confirm or rule out disease, (2) presymptomatic testing to determine whether an at-risk individual inherited the expanded allele, and (3) prenatal testing to determine whether the fetus has inherited the expanded allele. This unit includes protocols that describe the complementary use of polymerase chain reactions (PCR) and Southern blot hybridization to accurately measure the CAG trinucleotide repeat size and interpret the test results. In addition, an indirect linkage analysis that does not reveal the unwanted parental HD status in a prenatal testing will also be discussed.

  1. [Diagnostic workup of fragrance allergy].

    PubMed

    Geier, J; Uter, W

    2015-09-01

    The diagnostic workup of contact allergy to fragrances must not be limited to patch testing with the two well-established fragrance mixes. False-positive reactions to these mixes occur in up to 50 % of the patch tested patients. For the diagnostic work-up of positive reactions, and in cases of suspected fragrance allergy, patch testing with the single mix components and additional fragrances is mandatory. Frequently sensitizing fragrance materials are the 14 components of the two fragrance mixes and tree moss (Evernia furfuracea), ylang ylang oil (I + II; Cananga odorata), lemongrass oil (Cymbopogon schoenanthus), sandalwood oil (Santalum album), jasmine absolute (Jasminum spp.), and, less frequently, clove oil (Eugenia caryophyllus), cedarwood oil (Cedrus atlantica/deodara, Juniperus virginiana), Neroli oil (Citrus aurantium amara flower oil), salicylaldehyde, narcissus absolute (Narcissus spp.), and patchouli oil (Pogostemon cablin). PMID:26253114

  2. [Diagnostic workup of fragrance allergy].

    PubMed

    Geier, J; Uter, W

    2015-09-01

    The diagnostic workup of contact allergy to fragrances must not be limited to patch testing with the two well-established fragrance mixes. False-positive reactions to these mixes occur in up to 50 % of the patch tested patients. For the diagnostic work-up of positive reactions, and in cases of suspected fragrance allergy, patch testing with the single mix components and additional fragrances is mandatory. Frequently sensitizing fragrance materials are the 14 components of the two fragrance mixes and tree moss (Evernia furfuracea), ylang ylang oil (I + II; Cananga odorata), lemongrass oil (Cymbopogon schoenanthus), sandalwood oil (Santalum album), jasmine absolute (Jasminum spp.), and, less frequently, clove oil (Eugenia caryophyllus), cedarwood oil (Cedrus atlantica/deodara, Juniperus virginiana), Neroli oil (Citrus aurantium amara flower oil), salicylaldehyde, narcissus absolute (Narcissus spp.), and patchouli oil (Pogostemon cablin).

  3. A Diagnostic Procedural Model for Identifying Real Educational Needs.

    ERIC Educational Resources Information Center

    Londoner, Carroll

    This study evaluated educational problems and needs in the administrative management council of Bloomington Hospital, Bloomington, Indiana, in order to help produce a more effective task group within the hospital's institutional framework. Over a seven week period, the investigator observed department heads in their weekly conferences by means of…

  4. 40 CFR 85.2222 - Onboard diagnostic test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Mode $01, PID $01 request in accordance with 40 CFR 86.1806 to determine the OBD evaluation status. The... evaluation for applicable monitors in accordance with the requirements and specifications in 40 CFR 86.1806... with 40 CFR 86.1806 to determine the stored DTCs. The system shall repeat this cycle until the...

  5. Rayleigh Scattering Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard (Compiler)

    1996-01-01

    The Rayleigh Scattering Diagnostics Workshop was held July 25-26, 1995 at the NASA Lewis Research Center in Cleveland, Ohio. The purpose of the workshop was to foster timely exchange of information and expertise acquired by researchers and users of laser based Rayleigh scattering diagnostics for aerospace flow facilities and other applications. This Conference Publication includes the 12 technical presentations and transcriptions of the two panel discussions. The first panel was made up of 'users' of optical diagnostics, mainly in aerospace test facilities, and its purpose was to assess areas of potential applications of Rayleigh scattering diagnostics. The second panel was made up of active researchers in Rayleigh scattering diagnostics, and its purpose was to discuss the direction of future work.

  6. Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.

    ERIC Educational Resources Information Center

    Clancey, William J.

    This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…

  7. [Sedation using ketamine for pain procedures in Pediatric Oncology.].

    PubMed

    Ricard, C; Tichit, R; Troncin, R; Bernard, F

    2009-09-01

    Procedural sedation and analgesia for children is widely practiced. Since 2005 to 2007, we evaluated the safety and efficacy of ketamine to control pain induced by diagnostic procedures in pediatric oncology patients. Eight hundred fifty procedures were carried out in 125 patients aged 2 to 16 years. We associated EMNO (inhaled equimolar mixture of nitrous oxide and oxygen), atropin (oral or rectal), midazolam (oral or rectal) and ketamin (intravenous). An anesthesiologist injected ketamin. Average dose of ketamine was 0.33 to 2 mg/kg depending on number and invasiveness of procedures. This method requires careful monitoring and proper precautions. With these conditions, no complication was observed. All patients were effectively sedated. These results indicate that ketamine - in association with EMNO, atropine and midazolam - is safe and effective in pain management induced by diagnostic procedures in pediatric oncology patients. The sedative regimen of intravenous ketamine has greatly reduced patient, family and practitioners anxiety for diagnostic and therapeutic procedures.

  8. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  9. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  10. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  11. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  12. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  13. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    SciTech Connect

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-21

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  14. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    NASA Astrophysics Data System (ADS)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  15. Cryptosporidiosis: multiattribute evaluation of six diagnostic methods.

    PubMed

    MacPherson, D W; McQueen, R

    1993-02-01

    Six diagnostic methods (Giemsa staining, Ziehl-Neelsen staining, auramine-rhodamine staining, Sheather's sugar flotation, an indirect immunofluorescence procedure, and a modified concentration-sugar flotation method) for the detection of Cryptosporidium spp. in stool specimens were compared on the following attributes: diagnostic yield, cost to perform each test, ease of handling, and ability to process large numbers of specimens for screening purposes by batching. A rank ordering from least desirable to most desirable was then established for each method by using the study attributes. The process of decision analysis with respect to the laboratory diagnosis of cryptosporidiosis is discussed through the application of multiattribute utility theory to the rank ordering of the study criteria. Within a specific health care setting, a diagnostic facility will be able to calculate its own utility scores for our study attributes. Multiattribute evaluation and analysis are potentially powerful tools in the allocation of resources in the laboratory.

  16. Melioidosis Diagnostic Workshop, 20131

    PubMed Central

    AuCoin, David; Baccam, Prasith; Baggett, Henry C.; Baird, Rob; Bhengsri, Saithip; Blaney, David D.; Brett, Paul J.; Brooks, Timothy J.G.; Brown, Katherine A.; Chantratita, Narisara; Cheng, Allen C.; Dance, David A.B.; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E.; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L.; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J.; Rolim, Dionne B.; Simpson, Andrew J.; Steinmetz, Ivo; Stoddard, Robyn A.; Stokes, Martha M.; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T.

    2015-01-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions. PMID:25626057

  17. Plasma diagnostic reflectometry

    SciTech Connect

    Cohen, B.I.; Afeyan, B.B.; Garrison, J.C.; Kaiser, T.B.; Luhmann, N.C. Jr.; Domier, C.W.; Chou, A.E.; Baang, S.

    1996-02-26

    Theoretical and experimental studies of plasma diagnostic reflectometry have been undertaken as a collaborative research project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Plasma Diagnostics Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. Theoretical analyses have explored the basic principles of reflectometry to understand its limitations, to address specific gaps in the understanding of reflectometry measurements in laboratory experiments, and to explore extensions of reflectometry such as ultra-short-pulse reflectometry. The theory has supported basic laboratory reflectometry experiments where reflectometry measurements can be corroborated by independent diagnostic measurements.

  18. Efficacy and Safety of Pancreatobiliary Endoscopic Procedures during Pregnancy

    PubMed Central

    Lee, Jae Joon; Lee, Sung Koo; Kim, Sang Hyung; Kim, Ga Hee; Park, Do Hyun; Lee, Sangsoo; Seo, Dongwan; Kim, Myung-Hwan

    2015-01-01

    Background/Aims Endoscopic therapy with endoscopic retrograde cholangiopancreatography (ERCP) has been suggested as an effective diagnostic and therapeutic tool for biliary and pancreatic disorders during pregnancy. In this report, we describe our experiences with pancreatobiliary endoscopic procedures during pregnancy. Methods We reviewed ERCP and endoscopic ultrasonography (EUS) procedures that were performed at a single tertiary care referral center between January 2002 and October 2013. Medical records were reviewed for the procedure indication, the duration of fluoroscopy, postprocedure complications, etc. Pregnancy outcomes and fetal complications were identified by chart review and phone calls to patients. Results A total of 10 ER-CPs and five EUSs were performed in 13 pregnant patients: four of whom underwent the procedure in the first trimester, eight in the second trimester, and one in the third trimester. Indications for endoscopic therapy included gallstone pancreatitis, obstructive jaundice with common bile duct (CBD) stone, asymptomatic CBD stone, pancreatic cyst, choledochal cyst, and acute cholecystitis. Only one patient had a complication, which was postprocedural hyperamylasemia. Two patients underwent an artificial abortion, one according to her own decision and the other due to an adverse drug reaction. Conclusions ERCP seems to be effective and safe for pregnant women. Additionally, EUS can be an alternative to ERCP during pregnancy. PMID:26087783

  19. Malaria diagnostics in clinical trials.

    PubMed

    Murphy, Sean C; Shott, Joseph P; Parikh, Sunil; Etter, Paige; Prescott, William R; Stewart, V Ann

    2013-11-01

    Malaria diagnostics are widely used in epidemiologic studies to investigate natural history of disease and in drug and vaccine clinical trials to exclude participants or evaluate efficacy. The Malaria Laboratory Network (MLN), managed by the Office of HIV/AIDS Network Coordination, is an international working group with mutual interests in malaria disease and diagnosis and in human immunodeficiency virus/acquired immunodeficiency syndrome clinical trials. The MLN considered and studied the wide array of available malaria diagnostic tests for their suitability for screening trial participants and/or obtaining study endpoints for malaria clinical trials, including studies of HIV/malaria co-infection and other malaria natural history studies. The MLN provides recommendations on microscopy, rapid diagnostic tests, serologic tests, and molecular assays to guide selection of the most appropriate test(s) for specific research objectives. In addition, this report provides recommendations regarding quality management to ensure reproducibility across sites in clinical trials. Performance evaluation, quality control, and external quality assessment are critical processes that must be implemented in all clinical trials using malaria tests.

  20. Sequencing Needs for Viral Diagnostics

    SciTech Connect

    Gardner, S N; Lam, M; Mulakken, N J; Torres, C L; Smith, J R; Slezak, T

    2004-01-26

    We built a system to guide decisions regarding the amount of genomic sequencing required to develop diagnostic DNA signatures, which are short sequences that are sufficient to uniquely identify a viral species. We used our existing DNA diagnostic signature prediction pipeline, which selects regions of a target species genome that are conserved among strains of the target (for reliability, to prevent false negatives) and unique relative to other species (for specificity, to avoid false positives). We performed simulations, based on existing sequence data, to assess the number of genome sequences of a target species and of close phylogenetic relatives (''near neighbors'') that are required to predict diagnostic signature regions that are conserved among strains of the target species and unique relative to other bacterial and viral species. For DNA viruses such as variola (smallpox), three target genomes provide sufficient guidance for selecting species-wide signatures. Three near neighbor genomes are critical for species specificity. In contrast, most RNA viruses require four target genomes and no near neighbor genomes, since lack of conservation among strains is more limiting than uniqueness. SARS and Ebola Zaire are exceptional, as additional target genomes currently do not improve predictions, but near neighbor sequences are urgently needed. Our results also indicate that double stranded DNA viruses are more conserved among strains than are RNA viruses, since in most cases there was at least one conserved signature candidate for the DNA viruses and zero conserved signature candidates for the RNA viruses.

  1. DNA Microarray-Based Diagnostics.

    PubMed

    Marzancola, Mahsa Gharibi; Sedighi, Abootaleb; Li, Paul C H

    2016-01-01

    The DNA microarray technology is currently a useful biomedical tool which has been developed for a variety of diagnostic applications. However, the development pathway has not been smooth and the technology has faced some challenges. The reliability of the microarray data and also the clinical utility of the results in the early days were criticized. These criticisms added to the severe competition from other techniques, such as next-generation sequencing (NGS), impacting the growth of microarray-based tests in the molecular diagnostic market.Thanks to the advances in the underlying technologies as well as the tremendous effort offered by the research community and commercial vendors, these challenges have mostly been addressed. Nowadays, the microarray platform has achieved sufficient standardization and method validation as well as efficient probe printing, liquid handling and signal visualization. Integration of various steps of the microarray assay into a harmonized and miniaturized handheld lab-on-a-chip (LOC) device has been a goal for the microarray community. In this respect, notable progress has been achieved in coupling the DNA microarray with the liquid manipulation microsystem as well as the supporting subsystem that will generate the stand-alone LOC device.In this chapter, we discuss the major challenges that microarray technology has faced in its almost two decades of development and also describe the solutions to overcome the challenges. In addition, we review the advancements of the technology, especially the progress toward developing the LOC devices for DNA diagnostic applications.

  2. Properties of plasma radiation diagnostics

    SciTech Connect

    Idzorek, G.C.; Oona, H.

    1996-06-01

    A number of diagnostics utilizing the radiation emitted from high-temperature plasmas have been developed at Los Alamos. Photoemissive x-ray diodes with photon energy bandpass filters provide time resolved rough spectral data from bout 6 eV to > 10 keV photon energy. Filtered silicon photodiodes can be used down to 1 eV and offer the advantages of nominally flat response and ability to operate in poor vacuum conditions. Both types of diodes will provide a rough time resolved spectrum and both are relatively inexpensive, reliable, and passive (i.e. no synchronization problems). For higher energy resolution bent crystal spectrographs are used in the x-ray region. With the addition of streak cameras or gated microchannel plates these systems provide data with high energy and high time resolution. To measure the total energy output a thin foil bolometer is used that measures the change in foil resistance as it is heated by the plasma radiation. Information on the physical location of the plasma is provided by a suite of visible framing cameras and x-ray pinhole cameras. By combining these diagnostics into a complementary set good diagnostic information can be guaranteed on any plasma experiment.

  3. [Validation of a diagnostic scoring system (Ohmann score) in acute appendicitis].

    PubMed

    Zielke, A; Sitter, H; Rampp, T A; Schäfer, E; Hasse, C; Lorenz, W; Rothmund, M

    1999-07-01

    A diagnostic scoring system, recently published by Ohmann et al. in this journal, was validated by analyzing the clinicopathological data of a consecutive series of 2,359 patients, admitted for suspicion of acute appendicitis. The results of the scoring system were compared to the results of clinical evaluation by junior (provisional) and senior surgeons (final clinical diagnosis). To assess the diagnostic ability of the score, the accuracy and positive predictive value were defined as the major diagnostic performance parameters; the rate of theoretical negative laparotomies and that of diagnostic errors served as the major procedural performance parameters. Of 2,359 patients admitted for suspected acute appendicitis, 662 were proven to have acute appendicitis by histology, for a prevalence of 28%. The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the provisional clinical diagnosis were 0.50, 0.94, 0.77, 0.83, and 0.82; 0.93, for the score 0.63, 0.93, 0.77, 0.86 and 0.84, and for the final clinical diagnosis 0.90, 0.94, 0.85, 0.96, and 0.93, respectively. Of the main diagnostic performance parameter, the accuracy of the score was significantly better than that of provisional clinical diagnosis (P < 0.05, chi 2 test). The score yielded a rate of negative appendecomies and laparotomies of 14.3 and 12.3%. With respect to the rate of overlooked cases of acute apendicitis, the score demonstrated a superior performance, with only 6 cases missed (0.9%). However, the number of patients with acute appendicitis, including those with perforated disease, who were not identified by the score, was almost four times that of the final clinical diagnosis (245 vs 63). With regard to the main procedural performance parameter, the score resulted in a significantly smaller number of diagnostic errors than the provisional clinical investigator (P < 0.05, chi 2 test). The results of this study indicate that the diagnostic scoring

  4. Aging and social expertise: the impact of trait-diagnostic information on impressions of others.

    PubMed

    Hess, T M; Auman, C

    2001-09-01

    Two studies were conducted to examine the bases for age differences in the construction of social inferences. In each study, adults aged from 20 to 80 years were presented with an impression formation task in which they first read brief behavioral descriptions of fictitious people and then made a trait inference and likability judgment about each person. Results were generally consistent with previous findings in showing that aging was associated with an increase in the weighting of trait-diagnostic information in making trait attributions. In addition, the pattern of age effects was only minimally affected by situational factors that have been known to influence the use of trait-diagnostic information. The findings are interpreted as demonstrating an aging-related increase in social expertise in which knowledge regarding the underlying bases for the behaviors of others has been translated in specific procedural knowledge. PMID:11554526

  5. Aging and social expertise: the impact of trait-diagnostic information on impressions of others.

    PubMed

    Hess, T M; Auman, C

    2001-09-01

    Two studies were conducted to examine the bases for age differences in the construction of social inferences. In each study, adults aged from 20 to 80 years were presented with an impression formation task in which they first read brief behavioral descriptions of fictitious people and then made a trait inference and likability judgment about each person. Results were generally consistent with previous findings in showing that aging was associated with an increase in the weighting of trait-diagnostic information in making trait attributions. In addition, the pattern of age effects was only minimally affected by situational factors that have been known to influence the use of trait-diagnostic information. The findings are interpreted as demonstrating an aging-related increase in social expertise in which knowledge regarding the underlying bases for the behaviors of others has been translated in specific procedural knowledge.

  6. Radioactive diagnostic agent

    SciTech Connect

    Shigematsu, A.; Aihara, M.; Matsuda, M.; Suzuki, A.; Tsuya, A.

    1984-02-07

    A radioactive diagnostic agent for renal cortex, adrenal cortex, myocardium, brain stem, spinal nerve, etc., which comprises as an essential component monoiodoacetic acid wherein the iodine atom is radioactive.

  7. Manual of diagnostic imaging

    SciTech Connect

    Gaylord, G.; Baker, S.; Davis, L.

    1988-01-01

    This book is on ordering and understanding the results of radiologic studies. Main sections are (I) Diagnostic Radiology serves as a basic introduction; (II) Diagnostic Modalities dedicates a chapter to each imaging modality in a clinical context, with a brief technical description and patient preparation guidelines; and (III) Organ System Imaging contains a chapter on each major organ system, covering the abilities and limitations of each modality to image a specific organ system and the significance of anatomic, physiologic, and general pathologic information.

  8. Diagnostics for pulmonary tuberculosis

    PubMed Central

    Cudahy, Patrick

    2016-01-01

    Tuberculosis (TB) remains a leading cause of human suffering and mortality despite decades of effective treatment being available. Accurate and timely diagnosis remains an unmet goal. The HIV epidemic has also led to new challenges in the diagnosis of TB. Several new developments in TB diagnostics have the potential to positively influence the global campaign against TB. We aim to review the performance of both established as well as new diagnostics for pulmonary TB in adults, and discuss the ongoing challenges. PMID:27005271

  9. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    SciTech Connect

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  10. Face-off: A new identification procedure for child eyewitnesses.

    PubMed

    Price, Heather L; Fitzgerald, Ryan J

    2016-09-01

    In 2 experiments, we introduce a new "face-off" procedure for child eyewitness identifications. The new procedure, which is premised on reducing the stimulus set size, was compared with the showup and simultaneous procedures in Experiment 1 and with modified versions of the simultaneous and elimination procedures in Experiment 2. Several benefits of the face-off procedure were observed: it was significantly more diagnostic than the showup procedure; it led to significantly more correct rejections of target-absent lineups than the simultaneous procedures in both experiments, and it led to greater information gain than the modified elimination and simultaneous procedures. The face-off procedure led to consistently more conservative responding than the simultaneous procedures in both experiments. Given the commonly cited concern that children are too lenient in their decision criteria for identification tasks, the face-off procedure may offer a concrete technique to reduce children's high choosing rates. (PsycINFO Database Record PMID:27608069

  11. Hemoptysis with diagnostic dilemma.

    PubMed

    Pramanik, Bimalendu

    2013-02-01

    Hemoptysis is a common symptom. Although initial diagnostic workup, including a chest radiograph, often gives a clue to the cause, it provides no diagnostic hints in 3.0-42.2% of episodes of hemoptysis. To describe those cases with no diagnostic hints at initial investigations, experts have used different terms, including unexplained hemoptysis, idiopathic hemoptysis, cryptogenic hemoptysis and hemoptysis with normal chest radiographs. As hemoptysis is a common symptom of bronchogenic carcinoma, there is a concern of having underlying malignancy. Physicians value high-resolution computed tomography and fiberoptic bronchoscopy as the next investigations to establish diagnosis. These investigations however are expensive and nonspecific results are common in those cases of hemoptysis where initial diagnostic workup gives no clues to the cause. As a result, controversies exist with regard to their use. In this article, the author has proposed diagnostic approaches to evaluate those cases of hemoptysis with no diagnostic hints at initial investigation, after extensive review of published articles related to the case scenario. PMID:23362818

  12. Neutron Diagnostics for NIF

    NASA Astrophysics Data System (ADS)

    Barnes, Cris W.; Berggren, R.; Caldwell, S.; Chrien, R. C.; Cverna, F.; Faulkner, J.; Mack, J. M.; Morgan, G. L.; Murphy, T. J.; Oertel, J. A.; Tegtmeier, J.; Walton, R.; Wilke, M.; Wilson, D. C.; Young, C. S.

    1999-11-01

    The National Ignition Facility (NIF) will be a pre-emminent facility for research on burning plasmas. Los Alamos National Laboratory is developing a focus area of coordinating fusion reaction product diagnostics on NIF and studying fusion burn. We will be developing ``core'' diagnostics for NIF including neutron time-of-flight and single-hit systems for ion temperature and neutron spectra, measurements of ``bang-time'' (time of fusion burn relative to start of laser pulse), and support for activation measurements for high-yield and radiochemical analysis. We are also developing advanced Phase 2 diagnostics including a gas Cerenkov burn history diagnostic and work on apertures and detectors for neutron imaging. This will include tests of these diagnostic systems on the OMEGA laser in the coming years. The measurement requirements and system descriptions of these NIF diagnostics will be described. This work was performed under the auspices of the U. S. Department of Energy by the Los Alamos National Laboratory under contract No. W-7405-Eng-36.

  13. [Diagnostics in osteology].

    PubMed

    Jakob, F; Genest, F; Seefried, L; Tsourdi, E; Lapa, C; Hofbauer, L C

    2016-07-01

    Clinical diagnostics in metabolic bone diseases cover a broad spectrum of conventional and state of the art methods ranging from the medical history and clinical examination to molecular imaging. Patient treatment is carried out in an interdisciplinary team due to the multiple interactions of bone with other organ systems. Diagnosis of osteoporosis is supported by high level national guidelines. A paradigm shift concerning the clinical relevance of bone mineral density measurement renders this now to be a strong risk factor rather than a diagnostic parameter, while strengthening the value of other clinical factors for risk assessment. The impact of parameters for muscle mass, structure and function is steadily increasing in all age groups. In order to identify underlying diseases that influence bone metabolism a panel of general laboratory diagnostic parameters is recommended. Markers for bone formation and resorption and specific parameters for the regulation of calcium and phosphate metabolism should be evaluated by specialists because they require diligence in preanalytics and experience in interpretation. Genetic diagnosis is well established for rare bone diseases while diagnostic panels are not yet available for routine diagnostics in polygenetic diseases such as osteoporosis. Conventional radiology is still very important to identify, e. g. fractures, osteolytic and osteoblastic lesions and extraosseous calcifications; however tomography-based methods which combine, e. g. scintigraphy or positron emission technologies with anatomical imaging are of increasing significance. Clinical diagnostics in osteology require profound knowledge and are subject to a dynamic evolution. PMID:27307159

  14. DEVELOPMENT OF SIGNAL PROCESSING TOOLS AND HARDWARE FOR PIEZOELECTRIC SENSOR DIAGNOSTIC PROCESSES

    SciTech Connect

    OVERLY, TIMOTHY G.; PARK, GYUHAE; FARRAR, CHARLES R.

    2007-02-09

    This paper presents a piezoelectric sensor diagnostic and validation procedure that performs in -situ monitoring of the operational status of piezoelectric (PZT) sensor/actuator arrays used in structural health monitoring (SHM) applications. The validation of the proper function of a sensor/actuator array during operation, is a critical component to a complete and robust SHM system, especially with the large number of active sensors typically involved. The method of this technique used to obtain the health of the PZT transducers is to track their capacitive value, this value manifests in the imaginary part of measured electrical admittance. Degradation of the mechanical/electric properties of a PZT sensor/actuator as well as bonding defects between a PZT patch and a host structure can be identified with the proposed procedure. However, it was found that temperature variations and changes in sensor boundary conditions manifest themselves in similar ways in the measured electrical admittances. Therefore, they examined the effects of temperature variation and sensor boundary conditions on the sensor diagnostic process. The objective of this study is to quantify and classify several key characteristics of temperature change and to develop efficient signal processing techniques to account for those variations in the sensor diagnostis process. In addition, they developed hardware capable of making the necessary measurements to perform the sensor diagnostics and to make impedance-based SHM measurements. The paper concludes with experimental results to demonstrate the effectiveness of the proposed technique.

  15. Saliva as a non-invasive diagnostic tool for inflammation and insulin-resistance

    PubMed Central

    Desai, Gauri S; Mathews, Suresh T

    2014-01-01

    Saliva has been progressively studied as a non-invasive and relatively stress-free diagnostic alternative to blood. Currently, saliva testing is used for clinical assessment of hormonal perturbations, detection of HIV antibodies, DNA analysis, alcohol screening, and drug testing. Recently, there has been increasing interest in evaluating the diagnostic potential of saliva in obesity, inflammation, and insulin-resistance. Current literature has demonstrated elevated levels of inflammatory biomarkers including C-reactive protein, tumor necrosis factor-α, interleukin-6, and interferon-γ in saliva of obese/overweight children and adults. Salivary antioxidant status has also been studied as a measure of oxidative stress in individuals with type 2 diabetes. Further, several studies have demonstrated correlations of salivary markers of stress and insulin resistance including cortisol, insulin, adiponectin, and resistin with serum concentrations. These findings suggest the potential diagnostic value of saliva in health screening and risk stratification studies, particularly in the pediatric population, with implications for inflammatory, metabolic and cardiovascular conditions. However, additional studies are required to standardize saliva collection and storage procedures, validate analytical techniques for biomarker detection, and establish reference ranges for routine clinical use. The purpose of this review is to summarize and evaluate recent advancements in using saliva as a diagnostic tool for inflammation and insulin-resistance. PMID:25512775

  16. Effects of temperature variations on piezoelectric sensor diagnostics process based on impedance measurements (presentation video)

    NASA Astrophysics Data System (ADS)

    Jo, HyeJin; Park, Tong-il; Park, Gyehae

    2014-05-01

    A sensor diagnostic and validation process that performs in-situ monitoring of the operational status of piezoelectric (PZT) active-sensors in structural health monitoring (SHM) applications is presented. The basis of this process is to track the changes in the capacitive value of piezoelectric materials, which shows up in measured admittance. Both degradation of the mechanical/electrical properties of a PZT transducer and the bonding defects between a PZT patch and a host structure could be identified by the proposed process. Due to the temperature dependent nature of piezoelectric materials, we investigated the effects of temperature on sensor diagnostic process. The effect of temperature found to be remarkable, modifying the measured capacitive values significantly. This results indicates that there is need for developing a rigorous signal processing technique to normalizing the temperature effects. It has been also found that, as the temperature changes, the sensor diagnostic process was influenced not only by a sensor and a structure, but by a bonding materials that was used for attaching a piezoelectric transducers to a structure, which would be an important characteristic when designing an SHM system. This paper summarizes considerations needed to develop such sensor diagnostic processes, experimental procedures and results, and additional issues that can be used as guidelines for future investigations.

  17. Advanced smile diagnostics using CAD/CAM mock-ups.

    PubMed

    Sancho-Puchades, Manuel; Fehmer, Vincent; Hämmerle, Christoph; Sailer, Irena

    2015-01-01

    Diagnostics are essential for predictable restorative dentistry. Both patient and clinician must agree on a treatment goal before the final restorations are delivered to avoid future disappointments. However, fully understanding the patient's desires is difficult. A useful tool to overcome this problem is the diagnostic wax-up and mock-up. A potential treatment outcome is modeled in wax prior to treatment and transferred into the patient's mouth using silicon indexes and autopolymerizing resin to obtain the patient's approval. Yet, this time-consuming procedure only produces a single version of the possible treatment outcome, which can be unsatisfactory for both the patient and the restorative team. Contemporary digital technologies may provide advantageous features to aid in this diagnostic treatment step. This article reviews opportunities digital technologies offer in the diagnostic phase, and presents clinical cases to illustrate the procedures.

  18. [Diagnostic imaging of splenic disease].

    PubMed

    Völk, M; Strotzer, M

    2006-03-01

    Primary diseases of the spleen are relatively rare. More frequently, the spleen is involved secondarily in hematological, oncological, infectious, immunological, vascular, and other systemic diseases. The spleen is the most commonly injured organ in blunt abdominal trauma. Anatomical and physiological basics are explained, in addition to embryological facts with resulting abnormalities, such as accessory and "wandering" spleen, and polysplenia. The most frequent primary and secondary diseases of the spleen, including rare diagnoses, are presented and illustrated. Hemangioma represents the most common primary benign tumor, and lymphoma the most common primary malignant tumor of the spleen. Diagnostic imaging does not a allow safe differentiation between Hodgkin's and non-Hodgkin's lymphoma. One section deals with the clinical value and diagnostic workup of incidentally detected lesions. Simple cysts and calcifications need neither clarification nor a follow-up examination. Atypical cysts should be controlled within 3-6 months. Additional clarification using CT or MRT should be reserved for cases with a strong suspicion of clinically relevant primary or secondary splenic disease. PMID:16435091

  19. microRNA: Diagnostic Perspective

    PubMed Central

    Faruq, Omar; Vecchione, Andrea

    2015-01-01

    Biomarkers are biological measures of a biological state. An ideal marker should be safe and easy to measure, cost efficient, modifiable with treatment, and consistent across gender and ethnic groups. To date, none of the available biomarkers satisfy all of these criteria. In addition, the major limitations of these markers are low specificity, sensitivity, and false positive results. Recently identified, microRNAs (miRNAs) are endogenous, evolutionarily conserved small non-coding RNA (about 22–25 nt long), also known as micro-coordinators of gene expression, which have been shown to be an effective tools to study the biology of diseases and to have great potential as novel diagnostic and prognostic biomarkers with high specificity and sensitivity. In fact, it has been demonstrated that miRNAs play a pivotal role in the regulation of a wide range of developmental and physiological processes and their deficiencies have been related to a number of disease. In addition, miRNAs are stable and can be easily isolated and measured from tissues and body fluids. In this review, we provide a perspective on emerging concepts and potential usefulness of miRNAs as diagnostic markers, emphasizing the involvement of specific miRNAs in particular tumor types, subtypes, cardiovascular diseases, diabetes, infectious diseases, and forensic test. PMID:26284247

  20. Development of Companion Diagnostics.

    PubMed

    Mankoff, David A; Edmonds, Christine E; Farwell, Michael D; Pryma, Daniel A

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient's cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has "hit" the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2-targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.

  1. MJO Simulation Diagnostics

    SciTech Connect

    Waliser, D; Sperber, K; Hendon, H; Kim, D; Maloney, E; Wheeler, M; Weickmann, K; Zhang, C; Donner, L; Gottschalck, J; Higgins, W; Kang, I; Legler, D; Moncrieff, M; Schubert, S; Stern, W; Vitart, F; Wang, B; Wang, W; Woolnough, S

    2008-06-02

    The Madden-Julian Oscillation (MJO) interacts with, and influences, a wide range of weather and climate phenomena (e.g., monsoons, ENSO, tropical storms, mid-latitude weather), and represents an important, and as yet unexploited, source of predictability at the subseasonal time scale. Despite the important role of the MJO in our climate and weather systems, current global circulation models (GCMs) exhibit considerable shortcomings in representing this phenomenon. These shortcomings have been documented in a number of multi-model comparison studies over the last decade. However, diagnosis of model performance has been challenging, and model progress has been difficult to track, due to the lack of a coherent and standardized set of MJO diagnostics. One of the chief objectives of the US CLIVAR MJO Working Group is the development of observation-based diagnostics for objectively evaluating global model simulations of the MJO in a consistent framework. Motivation for this activity is reviewed, and the intent and justification for a set of diagnostics is provided, along with specification for their calculation, and illustrations of their application. The diagnostics range from relatively simple analyses of variance and correlation, to more sophisticated space-time spectral and empirical orthogonal function analyses. These diagnostic techniques are used to detect MJO signals, to construct composite life-cycles, to identify associations of MJO activity with the mean state, and to describe interannual variability of the MJO.

  2. Development of Companion Diagnostics.

    PubMed

    Mankoff, David A; Edmonds, Christine E; Farwell, Michael D; Pryma, Daniel A

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient's cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has "hit" the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2-targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic. PMID:26687857

  3. Development of Companion Diagnostics

    PubMed Central

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; Pryma, Daniel A.

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic. PMID:26687857

  4. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    SciTech Connect

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  5. Diagnostics for FIRE: A status report

    NASA Astrophysics Data System (ADS)

    Young, Kenneth M.

    2003-03-01

    The mission for the proposed fusion ignition research experiment (FIRE) device is to "attain, explore, understand and optimize fusion-dominated plasmas." Operation at Q⩾5, for 20 s with a fusion power output of ˜150 MW is the major goal. Attaining this mission sets demands for plasma measurement which are at least as comprehensive as on present tokamaks, with the additional capabilities needed for control of the plasma and for understanding the effects of the alpha-particles. Because of the planned operation in advanced tokamak scenarios, with steep transport barriers, the diagnostic instrumentation must be able to provide fine spatial and temporal resolution. It must also be able to withstand the impact of the intense neutron and gamma irradiation. There are practical engineering issues of minimizing radiation streaming while providing essential diagnostic access to the plasma. Many components will operate close to the first wall, e.g., ceramics and mineral insulated cable for magnetic diagnostics and mirrors for optical diagnostics; these components must be selected and mounted so that they will operate and survive in fluxes which require special material selection. The measurement requirements have been assessed so that the diagnostics for the FIRE device can be defined. Clearly, a better set of diagnostics of alpha-particles than that available for TFTR is essential, since the alpha-particles provide the dominant sources of heating and of instability-drive in the plasma.

  6. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    PubMed Central

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  7. Recent improvements of the JET lithium beam diagnostic

    SciTech Connect

    Brix, M.; Morgan, P.; Stamp, M.; Zastrow, K.-D.; Dunai, D.; Meszaros, B.; Petravich, G.; Refy, D. I.; Szabolics, T.; Zoletnik, S.; Lupelli, I.; Marsen, S.; Melson, T. F.; Silva, C. [EURATOM Collaboration: JET-EFDA Contributors

    2012-10-15

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  8. ORION laser target diagnostics.

    PubMed

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics. PMID:23126904

  9. Beamlet laser diagnostics

    SciTech Connect

    Burkhart, S.C.; Behrendt, W.C.; Smith, I.

    1996-06-01

    Beamlet is instrumented extensively to monitor the performance of the overall laser system and many of its subsystems. Beam diagnostics, installed in key locations, are used to fully characterize the beam during its propagation through the multipass cavity and the laser`s output section. This article describes the diagnostics stations located on Beamlet and discusses the design, calibration, and performance of the Beamlet calorimeters. The authors used Nova`s diagnostics packages to develop the Beamlet design to determine beam energy, spatial profile, temporal profile, and other beam parameters. Technologic improvements within the last several years in controls, charge-coupled device (CCD) cameras, and fast oscilloscopes have allowed the authors to obtain more accurate measurements on the Beamlet laser system. They briefly cover some of these techniques, including a description of their LabVIEW based data acquisition system.

  10. ORION laser target diagnostics.

    PubMed

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  11. ORION laser target diagnostics

    SciTech Connect

    Bentley, C. D.; Edwards, R. D.; Andrew, J. E.; James, S. F.; Gardner, M. D.; Comley, A. J.; Vaughan, K.; Horsfield, C. J.; Rubery, M. S.; Rothman, S. D.; Daykin, S.; Masoero, S. J.; Palmer, J. B.; Meadowcroft, A. L.; Williams, B. M.; Gumbrell, E. T.; Fyrth, J. D.; Brown, C. R. D.; Hill, M. P.; Oades, K.; and others

    2012-10-15

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  12. Reversed field pinch diagnostics

    SciTech Connect

    Weber, P.G.

    1986-01-01

    The Reversed Field Pinch (RFP) is a toroidal, axisymmetric magnetic confinement configuration characterized by a magnetic field configuration in which the toroidal magnetic field is of similar strength to the poloidal field, and is reversed at the edge compared to the center. The RFP routinely operates at high beta, and is a strong candidate for a compact fusion device. Relevant attributes of the configuration will be presented, together with an overview of present and planned experiments and their diagnostics. RFP diagnostics are in many ways similar to those of other magnetic confinement devices (such as tokamaks); these lectures will point out pertinent differences, and will present some diagnostics which provide special insights into unique attributes of the RFP.

  13. PDX diagnostic control system

    SciTech Connect

    Mika, R.

    1981-01-01

    This paper describes a computer-base diagnostic control system operating on the PDX Tokamak. The prime function of the system is to control mechanical positioning devices associated with various diagnostics including Thomson Scattering, X-Ray Pulse Height Analyzer, Rotating Scanning Monochromator, Fast Ion Detection Experiment, Bolometers and Plasma Limiters. The diagnostic control system consists of a PDP-11/34 computer, a CAMAC system partitioned between the PDX control room and the PDX machine area, and special electronic control modules developed at PPL. The special modules include a digital closed loop motor controller and user interface control panel for control and status display. A standard control panel was developed for interfacing each system user with the PDP-11/34 computer, through specially developed CAMAC modules.

  14. [Diagnostic models. 2. Fabrication].

    PubMed

    Lefèvre, M; Vincent, G; L'Official-Vincent, M

    1989-09-01

    After describing in Part I the preparation of diagnostic cast, the authors describe the Wax Up preparation. Most of the definition of centric relation agree that the position of the mandible is slightly behind its position in centric occlusion. The Hinge axis position is used for mounting the cast on articulator. The final restauration must reconstruct both position and the occlusion should be established in front the centric occlusion. After equilibration anterior guidance is studied and restaured if necessary. After creating the different curve of occlusion, the final Wax Up is settled. The use of the diagnostic cast so obtained will be presented in Part III.

  15. Diagnostic hematology of reptiles.

    PubMed

    Stacy, Nicole I; Alleman, A Rick; Sayler, Katherine A

    2011-03-01

    The hematologic evaluation of reptiles is an indispensable diagnostic tool in exotic veterinary practice. The diversity of reptile species, their characteristic physiologic features, and effects of intrinsic and extrinsic factors present unique challenges for accurate interpretation of the hemogram. Combining the clinical presentation with hematologic findings provides valuable information in the diagnosis and monitoring of disease and helps guide the clinician toward therapy and further diagnostic testing. This article outlines the normal and pathologic morphology of blood cells of reptile species. The specific comparative aspects of reptiles are emphasized, and structural and functional abnormalities in the reptilian hemogram are described.

  16. Practical Diagnostics for Evaluating Residential Commissioning Metrics

    SciTech Connect

    Wray, Craig; Walker, Iain; Siegel, Jeff; Sherman, Max

    2002-06-11

    In this report, we identify and describe 24 practical diagnostics that are ready now to evaluate residential commissioning metrics, and that we expect to include in the commissioning guide. Our discussion in the main body of this report is limited to existing diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. Appendix C describes the 83 other diagnostics that we have examined in the course of this project, but that are not ready or are inappropriate for residential commissioning. Combined with Appendix B, Table 1 in the main body of the report summarizes the advantages and disadvantages of all 107 diagnostics. We first describe what residential commissioning is, its characteristic elements, and how one might structure its process. Our intent in this discussion is to formulate and clarify these issues, but is largely preliminary because such a practice does not yet exist. Subsequent sections of the report describe metrics one can use in residential commissioning, along with the consolidated set of 24 practical diagnostics that the building industry can use now to evaluate them. Where possible, we also discuss the accuracy and usability of diagnostics, based on recent laboratory work and field studies by LBNL staff and others in more than 100 houses. These studies concentrate on evaluating diagnostics in the following four areas: the DeltaQ duct leakage test, air-handler airflow tests, supply and return grille airflow tests, and refrigerant charge tests. Appendix A describes those efforts in detail. In addition, where possible, we identify the costs to purchase diagnostic equipment and the amount of time required to conduct the diagnostics. Table 1 summarizes these data. Individual equipment costs for the 24

  17. Standard procedures for adults in accredited sleep medicine centres in Europe.

    PubMed

    Fischer, Jürgen; Dogas, Zoran; Bassetti, Claudio L; Berg, Søren; Grote, Ludger; Jennum, Poul; Levy, Patrick; Mihaicuta, Stefan; Nobili, Lino; Riemann, Dieter; Puertas Cuesta, F Javier; Raschke, Friedhart; Skene, Debra J; Stanley, Neil; Pevernagie, Dirk

    2012-08-01

    The present paper describes standardized procedures within clinical sleep medicine. As such, it is a continuation of the previously published European guidelines for the accreditation of sleep medicine centres and European guidelines for the certification of professionals in sleep medicine, aimed at creating standards of practice in European sleep medicine. It is also part of a broader action plan of the European Sleep Research Society, including the process of accreditation of sleep medicine centres and certification of sleep medicine experts, as well as publishing the Catalogue of Knowledge and Skills for sleep medicine experts (physicians, non-medical health care providers, nurses and technologists), which will be a basis for the development of relevant educational curricula. In the current paper, the standard operational procedures sleep medicine centres regarding the diagnostic and therapeutic management of patients evaluated at sleep medicine centres, accredited according to the European Guidelines, are based primarily on prevailing evidence-based medicine principles. In addition, parts of the standard operational procedures are based on a formalized consensus procedure applied by a group of Sleep Medicine Experts from the European National Sleep Societies. The final recommendations for standard operational procedures are categorized either as 'standard practice', 'procedure that could be useful', 'procedure that is not useful' or 'procedure with insufficient information available'. Standard operational procedures described here include both subjective and objective testing, as well as recommendations for follow-up visits and for ensuring patients' safety in sleep medicine. The overall goal of the actual standard operational procedures is to further develop excellence in the practice and quality assurance of sleep medicine in Europe.

  18. Diagnostic Lessons as Assessment.

    ERIC Educational Resources Information Center

    Walker, Barbara J.

    Embedded in a sensitive instructional context rather than a stifling testing atmosphere, diagnostic lessons provide assessment that is reliable, practical, valid, and efficient. In this type of assessment, there are several determiners of instructional placement: (1) students' propensity to adapt strategies as a result of specified instruction,…

  19. Sexual Addiction: Diagnostic Problems

    ERIC Educational Resources Information Center

    Giugliano, John R.

    2009-01-01

    In recent years clinicians report a great deal of concern about definition, diagnostic assessment, and treatment modalities when dealing with what might be called out-of-control sexual behavior. Many terms have been used to describe the phenomenon of problematic sexual behavior. Many of these concepts overlap, some are no longer popular, and some…

  20. Diagnostic Testing Project.

    ERIC Educational Resources Information Center

    McArthur, David L.

    This paper presents an explanation of the program design of the three separate Pascal-language programs which comprise UCLA's Diagnostic Testing Package "DX." The three parts of the DX test package are three closely interrelated programs--Editest, Runtest, and Summary. Editest serves the following functions: (1) the creation of a suitable…

  1. Equivalent Diagnostic Classification Models

    ERIC Educational Resources Information Center

    Maris, Gunter; Bechger, Timo

    2009-01-01

    Rupp and Templin (2008) do a good job at describing the ever expanding landscape of Diagnostic Classification Models (DCM). In many ways, their review article clearly points to some of the questions that need to be answered before DCMs can become part of the psychometric practitioners toolkit. Apart from the issues mentioned in this article that…

  2. Heterodyne laser diagnostic system

    DOEpatents

    Globig, Michael A.; Johnson, Michael A.; Wyeth, Richard W.

    1990-01-01

    The heterodyne laser diagnostic system includes, in one embodiment, an average power pulsed laser optical spectrum analyzer for determining the average power of the pulsed laser. In another embodiment, the system includes a pulsed laser instantaneous optical frequency measurement for determining the instantaneous optical frequency of the pulsed laser.

  3. Diagnostics for induction accelerators

    SciTech Connect

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960`s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore`s Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail.

  4. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  5. [Incontinence - Etiology, diagnostics and Therapy].

    PubMed

    Frieling, Thomas

    2016-08-01

    Fecal incontinence is defined by the unintentional loss of solid or liquid stool, and anal incontinence includes leakage of gas and / or fecal incontinence. Anal-fecal incontinence is not a diagnosis but a symptom. Many patients hide the problem from their families, friends, and even their doctors. Epidemiologic studies indicate a prevalence between 7-15 %, up to 30 % in hospitals and up to 70 % in longterm care settings. Anal-fecal incontinence causes a significant socio-economic burden. There is no widely accepted approach for classifying anal-fecal incontinence available. Anal-fecal continence is maintained by anatomical factors, rectoanal sensation, and rectal compliance. The diagnostic approach comprises muscle and nerve injuries by iatrogenic, obstetric or surgical trauma, descending pelvic floor or associated diseases. A basic diagnostic workup is sufficient to characterize the different manifestations of fecal incontinence in most of the cases. This includes patient history with a daily stool protocol and digital rectal investigation. Additional investigations may include anorectal manometry, anal sphincter EMG, conduction velocity of the pudendal nerve, needle EMG, barostat investigation, defecography and the dynamic MRI. Therapeutic interventions are focused on the individual symptoms and should be provided in close cooperation with gastroenterologists, surgeons, gynecologists, urologists, physiotherapeutics and psychologists (nutritional-training, food fibre content, pharmacological treatment of diarrhea/constipation, toilet training, pelvic floor gymnastic, anal sphincter training, biofeedback). Surgical therapy includes the STARR operation for rectoanal prolapse and sacral nerve stimulation for chronic constipation and anal-fecal incontinence. Surgery should not be applied unless the diagnostic work-up is complete and all conservative treatment options failed. PMID:27557074

  6. Diagnostic versus therapeutic second-look surgery in patients with ovarian cancer.

    PubMed

    Janisch, H; Schieder, K; Koelbl, H

    1989-03-01

    Between August 1982 and January 1988, 82 patient with epithelial ovarian cancer underwent second-look laparotomy. Before second-look surgery, 37 patients (45%) were in clinical complete remission. Eleven of these women who had previously received complete surgery received a diagnostic second-look operation. Whereas the clinical diagnosis of a complete response was confirmed by second-look procedure in eight of these patients, positive tumour findings were still evident in four women. The other 26 women who did not have clinical evidence of disease underwent staging second-look laparatomy to complete primary surgery. However, 11 patients revealed macroscopic evidence of tumour. In addition, the second-look operation was classified as a staging procedure in two women despite progressive disease classified preoperatively, but with negative intra-abdominal tumour findings. A therapeutic second-look laparotomy was performed in 37 patients with clinical evidence of disease to remove as much tumour as possible. Second-look laparatomy as a palliative procedure was necessary in six patients. Considering the type of second-look procedure, the 39 patients (48%) who underwent a diagnostic or staging procedure revealed a significantly longer median survival time of 62 months compared with the 43 women (52%) who underwent therapeutic or palliative second-look surgery and had a median survival of 19 months (P less than 0.0003, Log Rank Test). In patients with positive tumour findings at the time of second-look surgery, therapeutic cytoreduction was not associated with an improved survival time. We conclude that second-look surgery should be performed only in patients who are clinically free of disease to evaluate their intraperitoneal tumour status.

  7. Studies and analyses of the Space Shuttle Main Engine: SSME failure data review, diagnostic survey and SSME diagnostic evaluation

    NASA Technical Reports Server (NTRS)

    Glover, R. C.; Kelley, B. A.; Tischer, A. E.

    1986-01-01

    The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.

  8. Performance of advanced trauma life support procedures in microgravity

    NASA Technical Reports Server (NTRS)

    Campbell, Mark R.; Billica, Roger D.; Johnston, Smith L 3rd; Muller, Matthew S.

    2002-01-01

    BACKGROUND: Medical operations on the International Space Station will emphasize the stabilization and transport of critically injured personnel and so will need to be capable of advanced trauma life support (ATLS). METHODS: We evaluated the ATLS invasive procedures in the microgravity environment of parabolic flight using a porcine animal model. Included in the procedures evaluated were artificial ventilation, intravenous infusion, laceration closure, tracheostomy, Foley catheter drainage, chest tube insertion, peritoneal lavage, and the use of telemedicine methods for procedural direction. RESULTS: Artificial ventilation was performed and appeared to be unaltered from the 1-G environment. Intravenous infusion, laceration closure, percutaneous dilational tracheostomy, and Foley catheter drainage were achieved without difficulty. Chest tube insertion and drainage were performed with no more difficulty than in the 1-G environment due to the ability to restrain patient, operator and supplies. A Heimlich valve and Sorenson drainage system were both used to provide for chest tube drainage collection with minimal equipment, without the risk of atmospheric contamination, and with the capability to auto-transfuse blood drained from a hemothorax. The use of telemedicine in chest tube insertion was demonstrated to be useful and feasible. Peritoneal lavage using a percutaneous technique, although requiring less training to perform, was found to be dangerous in weightlessness due to the additional pressure of the bowel on the anterior abdominal wall creating a high risk of bowel perforation. CONCLUSIONS: The performance of ATLS procedures in microgravity appears to be feasible with the exception of diagnostic peritoneal lavage. Minor modifications to equipment and techniques are required in microgravity to effect surgical drainage in the presence of altered fluid dynamics, to prevent atmospheric contamination, and to provide for the restraint requirements. A parabolic

  9. [Companion Diagnostics for Solid Tumors].

    PubMed

    Watanabe, Atsushi

    2015-11-01

    Companion diagnostics (CoDx) will likely continue to rapidly increase in number and application to disease areas including solid tumors, for example EGFR for gefitinib and ALK fusion gene for crizotinib in non-small-cell lung cancer; KRAS against the use of cetuximab and panitumumab in colorectal cancer; HER2 for trastuzumab in breast cancer. CoDx are an indispensable part of personalized medicine and pharmacogenomics. In CoDx development, there are still many challenges, such as the business model promoting cooperation between diagnostics and pharmaceutical companies, and also the regulations related to CoDx. The FDA notice on the development of CoDx in 2011 recommended the co-development of a new drug and CoDx as the best practice, and the Ministry of Health, Labour and Welfare in Japan also issued a statement in 2013. In addition, the recent discovery of many novel variants in the DNA sequence, advances in sequencing and genomic technology, and improved analytic methods have enabled the impact of germline and somatic mutations to be determined using multiplex diagnosis. The complex challenges to develop CoDx necessitate a close collaboration among academic institutions, regulatory authorities, and pharmaceutical companies. [Review]. PMID:26995877

  10. [Companion Diagnostics for Solid Tumors].

    PubMed

    Watanabe, Atsushi

    2015-11-01

    Companion diagnostics (CoDx) will likely continue to rapidly increase in number and application to disease areas including solid tumors, for example EGFR for gefitinib and ALK fusion gene for crizotinib in non-small-cell lung cancer; KRAS against the use of cetuximab and panitumumab in colorectal cancer; HER2 for trastuzumab in breast cancer. CoDx are an indispensable part of personalized medicine and pharmacogenomics. In CoDx development, there are still many challenges, such as the business model promoting cooperation between diagnostics and pharmaceutical companies, and also the regulations related to CoDx. The FDA notice on the development of CoDx in 2011 recommended the co-development of a new drug and CoDx as the best practice, and the Ministry of Health, Labour and Welfare in Japan also issued a statement in 2013. In addition, the recent discovery of many novel variants in the DNA sequence, advances in sequencing and genomic technology, and improved analytic methods have enabled the impact of germline and somatic mutations to be determined using multiplex diagnosis. The complex challenges to develop CoDx necessitate a close collaboration among academic institutions, regulatory authorities, and pharmaceutical companies. [Review].

  11. Fielding of the on-axis diagnostic package at Z

    SciTech Connect

    Hurst, M.J.; Nash, T.J.; Derzon, M.; Kellogg, J.W.; Torres, J.; McGurn, J.; Seaman, J.; Jobe, D.; Lazier, S.E.

    1998-06-01

    The authors have developed a comprehensive diagnostic package for observing z-pinch radiation along the pinch axis on the Z accelerator. The instrumentation, which was fielded on the axial package, are x-ray diagnostics requiring direct lines of sight to the target. The diagnostics require vacuum access to the center of the accelerator. The environment is a hostile one, where one must deal with an intense, energetic photon flux (>100 keV), EMP, debris (e.g. bullets or shrapnel), and mechanical shock in order for the diagnostics to survive. In addition, practical constraints require the package be refurbished and utilized on a once a day shot schedule. In spite of this harsh environment, the authors have successfully fielded the diagnostic package with a high survivability of the data and the instruments. In this paper, they describe the environment and issues related to the re-entrant diagnostic package`s implementation and maintenance.

  12. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease

    PubMed Central

    Ellingford, Jamie M.; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G.; Sergouniotis, Panagiotis I.; O'Sullivan, James; Lamb, Janine A.; Perveen, Rahat; Hall, Georgina; Newman, William G.; Bishop, Paul N.; Roberts, Stephen A.; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C.; Nemeth, Andrea H.; Black, Graeme C.M.

    2016-01-01

    Purpose To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Design Case series. Participants A total of 562 patients diagnosed with IRD. Methods We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Main Outcome Measures Diagnostic yield of genomic testing. Results Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15–45) uplift in diagnostic yield. Conclusions We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. PMID:26872967

  13. Nuclear diagnostics in support of ICF experiments

    SciTech Connect

    Moran, M.J.; Hall, J.

    1996-06-05

    As the yields of Inertial Confinement Fusion (ICF) experiments increase to NIF levels new diagnostic techniques for studying details of fusion burn behavior will become feasible. The new techniques will provide improved measurements of fusion burn temperature and history. Improved temperature measurements might be achieved with magnetic spectroscopy of fusion neutrons. High-bandwidth fusion reaction history will be measured with fusion-specific {gamma}-ray diagnostics. Additional energy-resolved {gamma}-ray might be able to study a selection of specific behaviors during fusion burn. Present ICF yields greater than 10{sup 13} neutrons are sufficient to demonstrate the basic methods that underlie the new techniques. As ICF yields increase, the diagnostics designs adjusted accordingly in order to provide clear and specific data on fusion burn performance.

  14. Molecular Diagnostic Applications in Colorectal Cancer

    PubMed Central

    Huth, Laura; Jäkel, Jörg; Dahl, Edgar

    2014-01-01

    Colorectal cancer, a clinically diverse disease, is a leading cause of cancer-related death worldwide. Application of novel molecular diagnostic tests, which are summarized in this article, may lead to an improved survival of colorectal cancer patients. Distinction of these applications is based on the different molecular principles found in colorectal cancer (CRC). Strategies for molecular analysis of single genes (as KRAS or TP53) as well as microarray based techniques are discussed. Moreover, in addition to the fecal occult blood testing (FOBT) and colonoscopy some novel assays offer approaches for early detection of colorectal cancer like the multitarget stool DNA test or the blood-based Septin 9 DNA methylation test. Liquid biopsy analysis may also exhibit great diagnostic potential in CRC for monitoring developing resistance to treatment. These new diagnostic tools and the definition of molecular biomarkers in CRC will improve early detection and targeted therapy of colorectal cancer.

  15. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS How Grants Are Made Procedures to Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474)...

  16. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS How Grants Are Made Procedures to Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474)...

  17. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS How Grants Are Made Procedures to Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474)...

  18. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS How Grants Are Made Procedures to Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474)...

  19. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Office of the Secretary, Department of Education DIRECT GRANT PROGRAMS How Grants Are Made Procedures to Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474)...

  20. Diagnostic sonography in general surgery.

    PubMed

    Hill, B A; Yamaguchi, K; Flynn, J J; Miller, D R

    1975-09-01

    Eighty-seven patients who had sonographic examinations at the Orange County Medical Center were studied retrospectively to evaluate the usefulness and reliability of this noninvasive technique, and sonographic results were compared with findings at operation or findings made using other diagnostic methods. With a variety of lesions, the overall accuracy of diagnosis by sonography was 85%. In the remaining 15% of studies, false-positive or false-negative results were observed. The accuracy varied with the organ involved, the greatest being renal and hepatic masses. Ultrasound, when used in addition to careful surgical assessment of the patient, was found to be most useful in the diagnosis and follow-up of abdominal problems in surgical patients.

  1. Evaluating Prevention and Intervention Procedures.

    ERIC Educational Resources Information Center

    Sullivan, Arthur P.; And Others

    1986-01-01

    States the process-outcome research and evaluation paradigm applied to alcohol and substance abuse prevention and intervention programs. Shows its application to efforts to improve students' and patients' self-esteem to be deficient in certain aspects and advocates additions to the evaluation procedures, most notably analysis of in-session change.…

  2. ASSESSING THE USE OF A STANDARDIZED DENTAL DIAGNOSTIC TERMINOLOGY

    PubMed Central

    Tokede, Oluwabunmi; White, Joel M.; Stark, Paul C.; Vaderhobli, Ram; Walji, Muhammad F.; Ramoni, Rachel B.; Schoonheim-Klein, Meta E.; Kimmes, Nicole S.; Tavares, Anamaria

    2012-01-01

    Although standardized terminologies, such as the International Classification of Diseases (ICD), have been in use in medicine for over a century, in the dental profession, efforts to standardize dental diagnostic terms have not achieved widespread acceptance. To address this gap, a standardized dental diagnostic terminology - the ‘EZcodes’ terminology was developed in 2009. Fifteen dental practices and schools in the United States and Europe have implemented the ‘EZcodes’. In this paper we report on the utilization and valid entry of the EZcodes at three of the dental schools that have adopted this standardized dental diagnostic terminology. Electronic data on the use of procedure codes with diagnostic terms from the three schools over a one-year period between July 2010 and June 2011 were aggregated. The diagnostic term and procedure code pairs were adjudicated by three calibrated dentists. Analyses were conducted to gain insight into the utilization and valid entry of the EZcodes diagnostic terminology in the one-year period extending from 7/1/2010 through 6/30/2011. Error proportions in the entry of diagnostic term (and by diagnostic category) were also computed. Within the twelve-month period included in the analysis, a total of 29,965 diagnostic terms and 249,411 procedure codes were entered at the three institutions resulting in a utilization proportion of 12%. Caries and periodontics were the more frequently used categories. More than 1000 of the available 1321 diagnostic terms were never used at the three institutions. Overall, 60.5% of the EZcodes entries were found to be valid. In summary, our results demonstrate low utilization of EZ codes in an electronic dental record and raise the need for specific training of dental providers on the importance of using dental diagnostic terminology and specifically how to use the terms within the EHR. This will serve to increase the use/correct use of the EZcodes diagnostic terminology and ultimately create a

  3. Cardiovascular modeling and diagnostics

    SciTech Connect

    Kangas, L.J.; Keller, P.E.; Hashem, S.; Kouzes, R.T.

    1995-12-31

    In this paper, a novel approach to modeling and diagnosing the cardiovascular system is introduced. A model exhibits a subset of the dynamics of the cardiovascular behavior of an individual by using a recurrent artificial neural network. Potentially, a model will be incorporated into a cardiovascular diagnostic system. This approach is unique in that each cardiovascular model is developed from physiological measurements of an individual. Any differences between the modeled variables and the variables of an individual at a given time are used for diagnosis. This approach also exploits sensor fusion to optimize the utilization of biomedical sensors. The advantage of sensor fusion has been demonstrated in applications including control and diagnostics of mechanical and chemical processes.

  4. Blast wave energy diagnostic.

    PubMed

    Tierney, Thomas E; Tierney, Heidi E; Idzorek, George C; Watt, Robert G; Peterson, Robert R; Peterson, Darrell L; Fryer, Christopher L; Lopez, Mike R; Jones, Michael C; Sinars, Daniel; Rochau, Gregory A; Bailey, James E

    2008-10-01

    The distance radiation waves that supersonically propagate in optically thick, diffusive media are energy sensitive. A blast wave can form in a material when the initially diffusive, supersonic radiation wave becomes transonic. Under specific conditions, the blast wave is visible with radiography as a density perturbation. [Peterson et al., Phys. Plasmas 13, 056901 (2006)] showed that the time-integrated drive energy can be measured using blast wave positions with uncertainties less than 10% at the Z Facility. In some cases, direct measurements of energy loss through diagnostic holes are not possible with bolometric and x-ray radiometric diagnostics. Thus, radiography of high compression blast waves can serve as a complementary technique that provides time-integrated energy loss through apertures. In this paper, we use blast waves to characterize the energy emerging through a 2.4 mm aperture and show experimental results in comparison to simulations. PMID:19044574

  5. Nanodevices in diagnostics

    PubMed Central

    Hu, Ye; Fine, Daniel H.; Tasciotti, Ennio; Bouamrani, Ali; Ferrari, Mauro

    2010-01-01

    The real-time, personalized and highly sensitive early-stage diagnosis of disease remains an important challenge in modern medicine. With the ability to interact with matter at the nanoscale, the development of nanotechnology architectures and materials could potentially extend subcellular and molecular detection beyond the limits of conventional diagnostic modalities. At the very least, nanotechnology should be able to dramatically accelerate biomarker discovery, as well as facilitate disease monitoring, especially of maladies presenting a high degree of molecular and compositional heterogeneity. This article gives an overview of several of the most promising nanodevices and nanomaterials along with their applications in clinical practice. Significant work to adapt nanoscale materials and devices to clinical applications involving large interdisciplinary collaborations is already underway with the potential for nanotechnology to become an important enabling diagnostic technology. PMID:20229595

  6. DIAGNOSTICS OF BNL ERL

    SciTech Connect

    POZDEYEV,E.; BEN-ZVI, I.; CAMERON, P.; GASSNER, D.; KAYRAN, D.; ET AL.

    2007-06-25

    The ERL Prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high-intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high-current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This paper outlines requirements on the ERL diagnostics and describes its setup and modes of operation.

  7. Sonographic diagnostics in dermatology.

    PubMed

    Ulrich, Jens; Schwürzer-Voit, Markus; Jenderka, Klaus-Vitold; Voit, Christiane

    2014-12-01

    Ultrasonography non-invasively visualizes changes within the skin, skin appendages, subcutaneous tissue, subcutaneous (regional) lymph nodes and peripheral vessels. Thus it is an established diagnostic tool in dermatology. Compared to X-ray, MRI and PET, ultrasonography has some advantages; however, it is more dependent on the individual experience of the investigator. Therefore a structured education and continuous training are necessary. This review describes the physical and technical basics, the administrative requirements and the main indications in dermatology.

  8. PML diagnostic criteria

    PubMed Central

    Aksamit, Allen J.; Clifford, David B.; Davis, Larry; Koralnik, Igor J.; Sejvar, James J.; Bartt, Russell; Major, Eugene O.; Nath, Avindra

    2013-01-01

    Objective: To establish criteria for the diagnosis of progressive multifocal leukoencephalopathy (PML). Methods: We reviewed available literature to identify various diagnostic criteria employed. Several search strategies employing the terms “progressive multifocal leukoencephalopathy” with or without “JC virus” were performed with PubMed, SCOPUS, and EMBASE search engines. The articles were reviewed by a committee of individuals with expertise in the disorder in order to determine the most useful applicable criteria. Results: A consensus statement was developed employing clinical, imaging, pathologic, and virologic evidence in support of the diagnosis of PML. Two separate pathways, histopathologic and clinical, for PML diagnosis are proposed. Diagnostic classification includes certain, probable, possible, and not PML. Conclusion: Definitive diagnosis of PML requires neuropathologic demonstration of the typical histopathologic triad (demyelination, bizarre astrocytes, and enlarged oligodendroglial nuclei) coupled with the techniques to show the presence of JC virus. The presence of clinical and imaging manifestations consistent with the diagnosis and not better explained by other disorders coupled with the demonstration of JC virus by PCR in CSF is also considered diagnostic. Algorithms for establishing the diagnosis have been recommended. PMID:23568998

  9. ITER Diagnostic First Wal

    SciTech Connect

    G. Douglas Loesser, et. al.

    2012-09-21

    The ITER Diagnostic Division is responsible for designing and procuring the First Wall Blankets that are mounted on the vacuum vessel port plugs at both the upper and equatorial levels This paper will discuss the effects of the diagnostic aperture shape and configuration on the coolant circuit design. The DFW design is driven in large part by the need to conform the coolant arrangement to a wide variety of diagnostic apertures combined with the more severe heating conditions at the surface facing the plasma, the first wall. At the first wall, a radiant heat flux of 35W/cm2 combines with approximate peak volumetric heating rates of 8W/cm3 (equatorial ports) and 5W/cm3 (upper ports). Here at the FW, a fast thermal response is desirable and leads to a thin element between the heat flux and coolant. This requirement is opposed by the wish for a thicker FW element to accommodate surface erosion and other off-normal plasma events.

  10. [Acromegaly: reducing diagnostic delay].

    PubMed

    Giustina, Andrea

    2016-08-01

    Diagnostic delay of acromegaly is still very relevant (6-8 years on average) without substantial changes in last twenty years. Clinical impact of this diagnostic delay is significant: tumor growth (2/3 of the patients at diagnosis bear a pituitary macroadenoma), development of irreversible complications (arthropathy, sleep apnea) and in all increased mortality. Reasons for this delay are related to the disease itself (facial and acral changes are very slow and subtle) but also to medical unawareness. Simple tools based on a few sufficiently sensitive and specific signs and symptoms which can trigger the diagnostic suspect would be useful in clinical practice. Global evaluation during follow-up (tumor volume, signs and symptoms, complications, circulating levels of growth hormone and its peripheral mediator IGF-I) has become crucial for the therapeutic decision making. In this regard, tools like SAGIT are now under validation and are expected to improve management of acromegaly. In fact, in the last 30 years there has been a relevant growth of the medical options to treat acromegaly and in the near future there will be an expansion of the medical options. This will greatly help the needed personalization of treatment which necessarily should consider patient convenience and preference and control of complications such as diabetes mellitus. PMID:27571562

  11. Microsphere based saliva diagnostics

    NASA Astrophysics Data System (ADS)

    Rissin, David M.; DiCesare, Christopher; Hayman, Ryan B.; Blicharz, Timothy M.; Walt, David R.

    2005-11-01

    Saliva presents a minimally invasive alternative medium to blood for performing diagnostics1. Microsphere sensors for ions, small organic molecules, and proteins are currently being developed and optical microarrays containing thousands of these sensors will be used for simultaneous multi-analyte analysis. The fiber bundle platform in use is 1mm in diameter and contains approximately 50,000 individually addressable 3.1μm fibers, each with an etched well capable of housing a single 3.1μm microsphere sensor. Micron-sized bead-based chemistries are produced in house, followed by deposition onto a fiber-optic bundle platform, allowing for multiplexed analysis. The ultimate goal is to develop a universal diagnostic system using saliva as the diagnostic medium. This platform will permit multiplexed analysis of a sample by integrating microfluidics with the optical arrays loaded with sensors capable of detecting relevant biomarkers associated with a wide range of disease states. Disease states that are currently under investigation include end stage renal disease (ESRD) and Sjoegrens Syndrome (SS).

  12. Microgravity Combustion Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Santoro, Gilbert J. (Editor); Greenberg, Paul S. (Editor); Piltch, Nancy D. (Editor)

    1988-01-01

    Through the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications (OSSA) at NASA Headquarters, a program entitled, Advanced Technology Development (ATD) was promulgated with the objective of providing advanced technologies that will enable the development of future microgravity science and applications experimental flight hardware. Among the ATD projects one, Microgravity Combustion Diagnostics (MCD), has the objective of developing advanced diagnostic techniques and technologies to provide nonperturbing measurements of combustion characteristics and parameters that will enhance the scientific integrity and quality of microgravity combustion experiments. As part of the approach to this project, a workshop was held on July 28 and 29, 1987, at the NASA Lewis Research Center. A small group of laser combustion diagnosticians met with a group of microgravity combustion experimenters to discuss the science requirements, the state-of-the-art of laser diagnostic technology, and plan the direction for near-, intermediate-, and long-term programs. This publication describes the proceedings of that workshop.

  13. Alpha Particle Diagnostic

    SciTech Connect

    Fisher, Ray, K.

    2009-05-13

    The study of burning plasmas is the next frontier in fusion energy research, and will be a major objective of the U.S. fusion program through U.S. collaboration with our international partners on the ITER Project. For DT magnetic fusion to be useful for energy production, it is essential that the energetic alpha particles produced by the fusion reactions be confined long enough to deposit a significant fraction of their initial ~3.5 MeV energy in the plasma before they are lost. Development of diagnostics to study the behavior of energetic confined alpha particles is a very important if not essential part of burning plasma research. Despite the clear need for these measurements, development of diagnostics to study confined the fast confined alphas to date has proven extremely difficult, and the available techniques remain for the most part unproven and with significant uncertainties. Research under this grant had the goal of developing diagnostics of fast confined alphas, primarily based on measurements of the neutron and ion tails resulting from alpha particle knock-on collisions with the plasma deuterium and tritium fuel ions. One of the strengths of this approach is the ability to measure the alphas in the hot plasma core where the interesting ignition physics will occur.

  14. Disclosure analysis procedures: reliability issues.

    PubMed

    Hux, K; Sanger, D; Reid, R; Maschka, A

    1997-01-01

    Performing disclosure analyses to supplement assessment procedures and facilitate intervention planning is only valuable if the observations are reliable. The purpose of the present study was to evaluate and compare four methods of assessing reliability on one discourse analysis procedure--a modified version of Damico's Clinical Discourse Analysis (1985a, 1985b, 1992). The selected methods were: (a) Pearson product-moment correlations, (b) interobserver agreement, (c) Cohen's kappa, and (d) generalizability coefficients. Results showed high correlation coefficients and high percentages of interobserver agreement when error type was not taken into account. However, interobserver agreement percentages obtained solely for target behavior occurrences and Cohen's kappa revealed that much of the agreement between rates was due to chance and the high frequency of target behavior non-occurrence. Generalizability coefficients revealed that the procedure was fair to good for discriminating among persons with differing levels of language competency for some aspects of communication performance but was less than desirable for others; the aggregate score was below recommended standards for differentiating among people for diagnostic purposes.

  15. Microwave diagnostics of atmospheric plasmas

    NASA Astrophysics Data System (ADS)

    Scott, David

    Plasma treatment of biological tissues has tremendous potential due to the wide range of applications. Most plasmas have gas temperatures which greatly exceed room temperature. These are often utilized in electro-surgery for cutting and coagulating tissue. Another type of plasma, referred to as cold atmospheric plasma, or CAP, is characterized by heavy particle temperatures which are at or near room temperature. Due to this lack of thermal effect, CAP may provide less invasive medical procedures. Additionally, CAP have been demonstrated to be effective at targeting cancer cells while minimizing damage to the surrounding tissue. A recently fabricated Microwave Electron Density Device (MEDD) utilizes microwave scattering on small atmospheric plasmas to determine the electron plasma density. The MEDD can be utilized on plasmas which range from a fraction of a millimeter to several centimeters at atmospheric pressure when traditional methods cannot be applied. Microwave interferometry fails due to the small size of the plasma relative to the microwave wavelength which leads to diffraction and negligible phase change; electrostatic probes introduce very strong perturbation and are associated with difficulties of application in strongly-collisional atmospheric conditions; and laser Thomson scattering is not sensitive enough to measure plasma densities less than 1012 cm-3. The first part of this dissertation provides an overview of two types of small atmospheric plasma objects namely CAPs and plasmas utilized in the electro-surgery. It then goes on to describe the fabrication, testing and calibration of the MEDD facility. The second part of this dissertation is focused on the application of the MEDD and other diagnostic techniques to both plasma objects. A series of plasma images that illustrate the temporal evolution of a discharge created by an argon electrosurgical device operating in the coagulation mode and its behavior was analyzed. The discharge of the argon

  16. Minimally invasive procedures for neuropathic pain.

    PubMed

    Sdrulla, Andrei; Chen, Grace

    2016-04-01

    Neuropathic pain is "pain arising as a direct consequence of a lesion or disease affecting the somatosensory system". The prevalence of neuropathic pain ranges from 7 to 11% of the population and minimally invasive procedures have been used to both diagnose and treat neuropathic pain. Diagnostic procedures consist of nerve blocks aimed to isolate the peripheral nerve implicated, whereas therapeutic interventions either modify or destroy nerve function. Procedures that modify how nerves function include epidural steroid injections, peripheral nerve blocks and sympathetic nerve blocks. Neuroablative procedures include radiofrequency ablation, cryoanalgesia and neurectomies. Currently, neuromodulation with peripheral nerve stimulators and spinal cord stimulators are the most evidence-based treatments of neuropathic pain. PMID:26988024

  17. Numerical procedure for analyzing Langmuir probe data

    NASA Technical Reports Server (NTRS)

    Beattie, J. R.

    1975-01-01

    A numerical procedure is proposed for analyzing Langmuir probe data in the presence of a two-group plasma containing both primary and Maxwellian electrons. The procedure is known as a least-squares differential-correction technique for determining the unknown coefficients of the governing equation. It is shown that for a given set of input data the results of the analysis are unique and independent of the initial estimate of electron temperature, that convergence is fastest when electron temperature is overestimated, that the results are sensitive to the region of the curve used as input and also to the voltage increment, and that plasma properties determined by the proposed numerical procedure are either consistent with those determined graphically or closer to expected values. With a suitable data acquisition system, the Fortran IV program worked out for this procedure could be used to provide real-time plasma diagnostic information for an operating ion thruster.

  18. Current procedural terminology coding of nuclear medicine procedures.

    PubMed

    McKusick, K A; Quaife, M A

    1993-01-01

    The future of nuclear medicine is dependent on payment for new procedures. Today, the basis of payment by the federal government is a relative value unit (RVU) system; the RVUS employed in this system are for medical services and procedures listed and described in Physicians' Current Procedural Terminology, fourth edition. Current procedural terminology (CPT) is maintained by the AMA; annual revisions include adding new codes or revised or deleted old codes. This process involves all national medical specialty societies. Starting in 1992 a new process, the Relative Updating Committee, which was initiated by the AMA, organized medicine to formalize a method for recommending relative values for physician procedures and services. In this rapidly changing scenario, all nuclear medicine procedure codes are under review by the coding and nomenclature committees of the medical societies interested in imaging. Significant CPT changes and additions were made in the cardiovascular nuclear medicine codes in 1992, reflecting the current imaging protocols and pharmacological agents for performing cardiac stress testing and new codes that recognize combinations of ventricular function measurements in patients undergoing myocardial perfusion imaging with technetium-99m agents.

  19. [Munchausen's syndrome: a diagnostic challenge].

    PubMed

    Tlacuilo-Parra, J A; Guevara-Gutiérrez, E; Barrón-Pérez, E; Estrada-Contreras, M

    1999-01-01

    The Munchausen's syndrome is a variant of chronic factitious illness with predominantly physical signs and symptoms under the conscious control of the patient without any obvious gain. The disorder has also been called hospital addiction, professional patient syndrome and in the field of dermatology, dermatitis artefacta. Munchausen's syndrome may mimic many different conditions, especially acute abdominal pain, hemorrhagic disorders, rheumatologic manifestations, factitious fever, and injury of skin. We describe a 28-year-old woman, who was admitted at a local teaching hospital and studied during three years with complaints of a bleeding ulcer on the left knee, severe enough to require blood transfusions. Many procedures and tests were performed without pathologic findings. Afterward, she was seen at our institution; during the study, the suspicion had arisen that the patient had manipulated her ulcer, after the diagnosis of factitious disease was communicated, she admitted. Munchausen's syndrome may have a broad spectrum of manifestations; early recognition can avoid unnecessary treatments and invasive diagnostic studies, with their inherent risk of complications.

  20. Bronchoscopic procedures and lung biopsies in pediatric lung transplant recipients.

    PubMed

    Wong, Jackson Y; Westall, Glen P; Snell, Gregory I

    2015-12-01

    Bronchoscopy remains a pivotal diagnostic and therapeutic intervention in pediatric patients undergoing lung transplantation (LTx). Whether performed as part of a surveillance protocol or if clinically indicated, fibre-optic bronchoscopy allows direct visualization of the transplanted allograft, and in particular, an assessment of the patency of the bronchial anastomosis (or tracheal anastomosis following heart-lung transplantation). Additionally, bronchoscopy facilitates differentiation of infective processes from rejection episodes through collection and subsequent assessment of bronchoalveolar lavage (BAL) and transbronchial biopsy (TBBx) samples. Indeed, the diagnostic criteria for the grading of acute cellular rejection is dependent upon the histopathological assessment of biopsy samples collected at the time of bronchoscopy. Typically, performed in an out-patient setting, bronchoscopy is generally a safe procedure, although complications related to hemorrhage and pneumothorax are occasionally seen. Airway complications, including stenosis, malacia, and dehiscence are diagnosed at bronchoscopy, and subsequent management including balloon dilatation, laser therapy and stent insertion can also be performed bronchoscopically. Finally, bronchoscopy has been and continues to be an important research tool allowing a better understanding of the immuno-biology of the lung allograft through the collection and analysis of collected BAL and TBBx samples. Whilst new investigational tools continue to evolve, the simple visualization and collection of samples within the lung allograft by bronchoscopy remains the gold standard in the evaluation of the lung allograft. This review describes the use and experience of bronchoscopy following lung transplantation in the pediatric setting.

  1. Photovoltaic array space power plus diagnostics experiment

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1990-01-01

    The objective is to summarize the five years of hardware development and fabrication represented by the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) Instrument. The original PASP Experiment requirements and background is presented along with the modifications which were requested to transform the PASP Experiment into the PASP Plus Instrument. The PASP Plus hardware and software is described. Test results for components and subsystems are given as well as final system tests. Also included are appendices which describe the major subsystems and present supporting documentation such as block diagrams, schematics, circuit board artwork, drawings, test procedures and test reports.

  2. Assessing Fit of Cognitive Diagnostic Models: A Case Study

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Almond, Russell G.

    2007-01-01

    A cognitive diagnostic model uses information from educational experts to describe the relationships between item performances and posited proficiencies. When the cognitive relationships can be described using a fully Bayesian model, Bayesian model checking procedures become available. Checking models tied to cognitive theory of the domains…

  3. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES

    EPA Science Inventory

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  4. The Development of a Vocational Diagnostic Program. Interim Report.

    ERIC Educational Resources Information Center

    Barnard, William W.

    A five-phased project is described which was designed to develop more specific diagnostic procedures and instrumentation that would allow both the vocational counselor and the prospective student to determine more effectively specific occupational programs and occupational objectives for education at the postsecondary level. Phases of the project…

  5. Diagnostic utility of cholescintigraphy and ultrasonography in acute cholecystitis

    SciTech Connect

    Zeman, R.K.; Burrell, M.I.; Cahow, C.E.; Caride, V.

    1981-04-01

    When faced with a patient with possible acute cholecystitis, technetium-99m-HIDA scintigraphy should be the primary diagnostic procedure performed. If scintigraphy reveals a normal gallbladder, acute cholecystitis is excluded. If the scintigram fails to visualize the gallbladder, ultrasonography is deemed advisable to exclude potential false-positive scintigrams and confirm the presence of cholelithiasis.

  6. 40 CFR 35.1605-8 - Diagnostic-feasibility study.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... condition and to develop possible methods for lake restoration and protection. (a) The diagnostic portion of..., demographic, socio-economic, and other pertinent characteristics of the lake and its watershed. This... schedule for implementing pollution control measures and in-lake restoration procedures; and (4)...

  7. 40 CFR 35.1605-8 - Diagnostic-feasibility study.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condition and to develop possible methods for lake restoration and protection. (a) The diagnostic portion of..., demographic, socio-economic, and other pertinent characteristics of the lake and its watershed. This... schedule for implementing pollution control measures and in-lake restoration procedures; and (4)...

  8. 40 CFR 35.1605-8 - Diagnostic-feasibility study.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... condition and to develop possible methods for lake restoration and protection. (a) The diagnostic portion of..., demographic, socio-economic, and other pertinent characteristics of the lake and its watershed. This... schedule for implementing pollution control measures and in-lake restoration procedures; and (4)...

  9. 40 CFR 35.1605-8 - Diagnostic-feasibility study.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... condition and to develop possible methods for lake restoration and protection. (a) The diagnostic portion of..., demographic, socio-economic, and other pertinent characteristics of the lake and its watershed. This... schedule for implementing pollution control measures and in-lake restoration procedures; and (4)...

  10. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  11. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic

  12. Extension of the standard addition method by blank addition.

    PubMed

    Steliopoulos, Panagiotis

    2015-01-01

    Standard addition involves adding varying amounts of the analyte to sample portions of fixed mass or fixed volume and submitting those portions to the sample preparation procedure. After measuring the final extract solutions, the observed signals are linearly regressed on the spiked amounts. The original unknown amount is estimated by the opposite of the abscissa intercept of the fitted straight line [1]. A limitation of this method is that only data points with abscissa values equal to and greater than zero are available so that there is no information on whether linearity holds below the spiking level zero. An approach to overcome this limitation is introduced.•Standard addition is combined with blank addition.•Blank addition means that defined mixtures of blank matrix and sample material are subjected to sample preparation to give final extract solutions.•Equations are presented to estimate the original unknown amount and to calculate the 1-2α confidence interval about this estimate using the combined data set.

  13. Extension of the standard addition method by blank addition

    PubMed Central

    Steliopoulos, Panagiotis

    2015-01-01

    Standard addition involves adding varying amounts of the analyte to sample portions of fixed mass or fixed volume and submitting those portions to the sample preparation procedure. After measuring the final extract solutions, the observed signals are linearly regressed on the spiked amounts. The original unknown amount is estimated by the opposite of the abscissa intercept of the fitted straight line [1]. A limitation of this method is that only data points with abscissa values equal to and greater than zero are available so that there is no information on whether linearity holds below the spiking level zero. An approach to overcome this limitation is introduced.•Standard addition is combined with blank addition.•Blank addition means that defined mixtures of blank matrix and sample material are subjected to sample preparation to give final extract solutions.•Equations are presented to estimate the original unknown amount and to calculate the 1-2α confidence interval about this estimate using the combined data set. PMID:26844210

  14. MALDI-TOF MS in microbiological diagnostics-identification of microorganisms and beyond (mini review).

    PubMed

    Wieser, Andreas; Schneider, Lukas; Jung, Jette; Schubert, Sören

    2012-02-01

    Few developments in microbiological diagnostics have had such a rapid impact on species level identification of microorganisms as matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS). Conventional differentiation methods rely on biochemical criteria and require additional pre-testing and lengthy incubation procedures. In comparison, MALDI-TOF MS can identify bacteria and yeast within minutes directly from colonies grown on culture plates. This radically new, methodically simple approach profoundly reduces the cost of consumables and time spent on diagnostics. The reliability and accuracy of the method have been demonstrated in numerous studies and different systems are already commercially available. Novel applications of the system besides microbial species level identification are also being explored. This includes identification of pathogens from positive blood cultures or directly from patient samples, such as urine. Currently, intriguing MALDI-TOF MS developments are being made regarding the phenotypic detection of certain antibiotic resistance mechanisms, e.g., β-lactamases and carbapenemases. This mini review provides an overview of the literature in the field and also includes our own data and experiences gathered from over 4 years of routine MALDI-TOF MS use in a university hospital's microbiological diagnostics facility.

  15. A Framework for Determining the Value of Diagnostic Information for Instructional Decision-Making

    ERIC Educational Resources Information Center

    Armstrong, David G.

    1976-01-01

    A procedure designed to help instructional decision-makers evaluate individual sources of diagnostic information in terms of their functional utility may add a desirable measure of precision to their instructional prescriptions for learners. (Author)

  16. [Ultrasound diagnostics in ophthalmology (standardized echography): part 1: principles and diseases of the eyeball].

    PubMed

    Hasenfratz, G; Mardin, C

    2014-10-01

    Ultrasound diagnostics has been one of the most important additional diagnostic non-invasive techniques in ophthalmology for many decades and is essential for many intraocular and orbital diseases. When echographic investigations and analysis of the echograms obtained are correctly carried out, ultrasound diagnostics demonstrates a high degree of specificity and sensitivity.

  17. Surgical procedures for voice restoration

    PubMed Central

    Nawka, Tadeus; Hosemann, Werner

    2005-01-01

    Surgical procedures for voice restoration serve to improve oral communication by better vocal function. They comprise of phonomicrosurgery, with direct and indirect access to the larynx; laryngoplasty; laryngeal injections; and surgical laryngeal reinnervation. The basis for modern surgical techniques for voice disorders is the knowledge about the ultrastructure of the vocal folds and the increasing experience of surgeons in voice surgery, while facing high social and professional demands on the voice. Vocal activity limitation and participation restriction has become more important in the artistic and social areas. A number of surgical methods that have been developed worldwide for this reason, are presented in this article. Functional oriented surgery has to meet high standards. The diagnostics of vocal function has to be multi-dimensional in order to determine the indication and the appropriate surgical intervention. PMID:22073062

  18. Planetary Transmission Diagnostics

    NASA Technical Reports Server (NTRS)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  19. FASTBUS Snoop Diagnostic Module

    SciTech Connect

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table.

  20. [Frontal mass: diagnostic challenges].

    PubMed

    Rubino, Gina; Correia, Alexandre; Rodrigues, Fernanda

    2012-01-01

    Capnocytophaga spp. are part of the oral flora of humans and animals, being responsible for skin and soft tissues infections and invasive infections. Microbiological identification can be difficult due to its slow growth. We present a case of infection caused by this bacteria in the form of an extracerebral intracranial abscess, presenting as a frontal mass that posed some diagnostic challenges. A surgical drainage was performed together with antibiotic therapy with favourable outcome. This microorganism was identified in the second week of treatment and then a careful history revealed a dog bite days prior to the initial symptoms. This could have been the site of entry to a posterior focalization. PMID:23069241

  1. Diagnostics for hybrid reactors

    SciTech Connect

    Orsitto, Francesco Paolo

    2012-06-19

    The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

  2. System-related factors contributing to diagnostic errors.

    PubMed

    Thammasitboon, Satid; Thammasitboon, Supat; Singhal, Geeta

    2013-10-01

    Several studies in primary care, internal medicine, and emergency departments show that rates of errors in test requests and result interpretations are unacceptably high and translate into missed, delayed, or erroneous diagnoses. Ineffective follow-up of diagnostic test results could lead to patient harm if appropriate therapeutic interventions are not delivered in a timely manner. The frequency of system-related factors that contribute directly to diagnostic errors depends on the types and sources of errors involved. Recent studies reveal that the errors and patient harm in the diagnostic testing loop have occurred mainly at the pre- and post-analytic phases, which are directed primarily by clinicians who may have limited expertise in the rapidly expanding field of clinical pathology. These errors may include inappropriate test requests, failure/delay in receiving results, and erroneous interpretation and application of test results to patient care. Efforts to address system-related factors often focus on technical errors in laboratory testing or failures in delivery of intended treatment. System-improvement strategies related to diagnostic errors tend to focus on technical aspects of laboratory medicine or delivery of treatment after completion of the diagnostic process. System failures and cognitive errors, more often than not, coexist and together contribute to the incidents of errors in diagnostic process and in laboratory testing. The use of highly structured hand-off procedures and pre-planned follow-up for any diagnostic test could improve efficiency and reliability of the follow-up process. Many feedback pathways should be established so that providers can learn if or when a diagnosis is changed. Patients can participate in the effort to reduce diagnostic errors. Providers should educate their patients about diagnostic probabilities and uncertainties. The patient-safety strategies focusing on the interface between diagnostic system and therapeutic

  3. [Food additives and healthiness].

    PubMed

    Heinonen, Marina

    2014-01-01

    Additives are used for improving food structure or preventing its spoilage, for example. Many substances used as additives are also naturally present in food. The safety of additives is evaluated according to commonly agreed principles. If high concentrations of an additive cause adverse health effects for humans, a limit of acceptable daily intake (ADI) is set for it. An additive is a risk only when ADI is exceeded. The healthiness of food is measured on the basis of nutrient density and scientifically proven effects.

  4. Designing Flightdeck Procedures

    NASA Technical Reports Server (NTRS)

    Barshi, Immanuel; Mauro, Robert; Degani, Asaf; Loukopoulou, Loukia

    2016-01-01

    The primary goal of this document is to provide guidance on how to design, implement, and evaluate flight deck procedures. It provides a process for developing procedures that meet clear and specific requirements. This document provides a brief overview of: 1) the requirements for procedures, 2) a process for the design of procedures, and 3) a process for the design of checklists. The brief overview is followed by amplified procedures that follow the above steps and provide details for the proper design, implementation and evaluation of good flight deck procedures and checklists.

  5. Computerized procedures system

    DOEpatents

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  6. Molecular diagnostics for low resource settings

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.

    2010-03-01

    As traditional high quality diagnostic laboratories are not widely available or affordable in developing country health care settings, microfluidics-based point-of-care diagnostics may be able to address the need to perform complex assays in under-resourced areas. Many instrument-based as well as non-instrumented microfluidic prototype diagnostics are currently being developed. In addition to various engineering challenges, the greatest remaining issue is the search for truly low-cost disposable manufacturing methods. Diagnostics for global health, and specifically microfluidics and molecular-based low resource diagnostics, have become a very active research area over the last five years, thanks in part to new funding that became available from the Bill and Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based lab-on-a-chips for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic acid amplification have been developed as well. Regardless of platform, however, the search for truly low-cost manufacturing methods that would result in cost of goods per disposable of around US1/unit at volume remains a big challenge. This talk will give an overview over existing platform development efforts as well as present some original research in this area at PATH.

  7. Patient radiation exposure in diagnostic radiology examinations: an overview. Summary report

    SciTech Connect

    Burkhart, R.L.

    1983-08-01

    The report surveys the published data on entrance skin exposure received by patients during diagnostic radiology examinations. It provides a reference source to aid radiology facilities in determining whether the amount of exposure received by their patients is appropriate for the diagnostic procedures employed.

  8. Diagnostic Care: Grade 9. Technology Learning Activity. Teacher Edition. Level 2. Technology Education Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…

  9. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  10. [Over diagnostic imaging in cardiology].

    PubMed

    Carpeggiani, Clara

    2014-03-01

    Medical imaging is one of the major cause of rising health care costs. Diagnostic imaging has increased more rapidly than any other component of medical care. About 5 billion imaging tests are performed worldwide each year. According to recent estimates, at least one-third of all examinations are partially or totally inappropriate. Two out of 3 imaging tests employ ionizing radiations with radiology or nuclear medicine. The medical use of radiation is the largest man-made source of radiation exposure. Medical X-rays and γ-rays are a proven human carcinogen. The attributable long-term extra-risk of cancer due to diagnostic testing is around 10% in industrialized countries. Cardiologists prescribe and/or directly perform >50% of all imaging examinations, accounting for about two-thirds of the total effective dose given to patients. The dose of common cardiological examinations may be significant: 500 chest X-rays= a stress scintigraphy with sestamibi, 750 chest X-rays= a Multislice Computed Tomography, 1,000 chest X-rays= a coronary angiography and stenting. Unfortunately, few doctors are aware of the level of radiation their patients are exposed to during radiological tests and more intensive use of ionizing testing was not associated with greater awareness. Also as a consequence of unawareness, the rate of inappropriate examinations is unacceptably high in cardiology, even for procedures with high radiation load. Higher exposure doses correspond to higher long-term risks; there are no safe doses, and all doses add up in determining the cumulative risks over a lifetime. Doctors should make every effort so that «each patient should get the right imaging exam, at the right time, with the right radiation dose», as suggested by US Food and Drug Administration in the 2010 initiative to reduce unnecessary radiation exposure from medical imaging. This is best obtained through a systematic implementation of the "3 A's strategy" proposed by the International Atomic Energy

  11. Advances in paper-based point-of-care diagnostics.

    PubMed

    Hu, Jie; Wang, ShuQi; Wang, Lin; Li, Fei; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng

    2014-04-15

    Advanced diagnostic technologies, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA), have been widely used in well-equipped laboratories. However, they are not affordable or accessible in resource-limited settings due to the lack of basic infrastructure and/or trained operators. Paper-based diagnostic technologies are affordable, user-friendly, rapid, robust, and scalable for manufacturing, thus holding great potential to deliver point-of-care (POC) diagnostics to resource-limited settings. In this review, we present the working principles and reaction mechanism of paper-based diagnostics, including dipstick assays, lateral flow assays (LFAs), and microfluidic paper-based analytical devices (μPADs), as well as the selection of substrates and fabrication methods. Further, we report the advances in improving detection sensitivity, quantification readout, procedure simplification and multi-functionalization of paper-based diagnostics, and discuss the disadvantages of paper-based diagnostics. We envision that miniaturized and integrated paper-based diagnostic devices with the sample-in-answer-out capability will meet the diverse requirements for diagnosis and treatment monitoring at the POC.

  12. Instrumentation and diagnostics

    SciTech Connect

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  13. Radiation hardening of diagnostics

    SciTech Connect

    Siemon, R.E.

    1991-01-01

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10{sup 16} neutrons per second because of spallation'' reactions when the protons collide with the copper nuclei in the beam stop.

  14. Diagnostic Technologies in Practice

    PubMed Central

    Steinberg, Malcolm; Kwag, Michael; Chown, Sarah A.; Doupe, Glenn; Trussler, Terry; Rekart, Michael; Gilbert, Mark

    2015-01-01

    Diagnosing HIV-positive gay men through enhanced testing technologies that detect acute HIV infection (AHI) or recent HIV infection provides opportunities for individual and population health benefits. We recruited 25 men in British Columbia who received an acute (n = 13) or recent (n = 12) HIV diagnosis to engage in a longitudinal multiple-methods study over one year or longer. Our thematic analysis of baseline qualitative interviews revealed insights within men’s accounts of technologically mediated processes of HIV discovery and diagnosis. Our analysis illuminated the dialectic of new HIV technologies in practice by considering the relationship between advances in diagnostics (e.g., nucleic acid amplification tests) and the users of these medical technologies in clinical settings (e.g., clients and practitioners). Technological innovations and testing protocols have shifted experiences of learning of one’s HIV-positive status; these innovations have created new diagnostic categories that require successful interpretation and translation to be rendered meaningful, to alleviate uncertainty, and to support public health objectives. PMID:25201583

  15. NIO1 diagnostics

    SciTech Connect

    Zaniol, B. Barbisan, M.; Pasqualotto, R.; Serianni, G.; Cavenago, M.; De Muri, M.; Mimo, A.

    2015-04-08

    The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

  16. Thioaptamer Diagnostic System (TDS)

    NASA Technical Reports Server (NTRS)

    Yang, Xianbin

    2015-01-01

    AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

  17. [Hemophagocytic syndrome: diagnostic problems].

    PubMed

    Czogała, Małgorzata; Czogała, Wojciech; Balwierz, Walentyna

    2006-01-01

    Hemophagocytic syndrome (HS) is a rare but life-threatening disease caused by inappropriate activation of T-lymphocytes and histiocytes, hipercytokinemia and hemophagocytosis. The most common symptoms are fever, hepatosplenomegaly, unspecific neurological abnormalities, pancytopenia, coagulopathy, hiperferritinemia and lipid abnormalities. HS is classified into two forms: primary, inherited (Familial Hamophagocytic Lymphohistiocytosis--FHL) and secondary (associated with infection, malignancy, autoimmune disease). In spite of the fact that diagnostic guidelines are available it often remains unrecognised. Prognosis of HS depends on the form of disease and in case of secondary HS on the underlying disease. Development of the treatment protocols (HLH-94, HLH-2004) which combine immunochemiotherapy with hematopoietic stem cell transplantation has strongly improved prognosis in HS especially in the primary form. Three-year overall survival for children with HS is now over 50%. Early diagnosis and appropriate therapy is crucial for effectiveness of the treatment. Popularisation of the knowledge about the syndrome, diagnostic guidelines and treatment protocols can contribute to more frequent appropriate recognition of HS and to improvement of the treatment results. PMID:16892901

  18. HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES

    SciTech Connect

    Ronald L. Boring; David I. Gertman; Katya Le Blanc

    2011-09-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  19. Complications of the Latarjet procedure.

    PubMed

    Gupta, Ashish; Delaney, Ruth; Petkin, Kalojan; Lafosse, Laurent

    2015-03-01

    The Latarjet procedure is an operation performed either arthroscopically or open for recurrent anterior shoulder instability, in the setting of glenoid bone loss; with good to excellent functional results. Despite excellent clinical results, the complication rates are reported between 15 and 30 %. Intraoperative complications such as graft malpositioning, neurovascular injury, and graft fracture can all be mitigated with meticulous surgical technique and understanding of the local anatomy. Nonunion and screw breakage are intermediate-term complications that occur in less than 5 % of patients. The long-term complications such as graft osteolysis are still an unsolved problem, and future research is required to understand the etiology and best treatment option. Recurrent instability after the Latarjet procedure can be managed with iliac crest bone graft reconstruction of the anterior glenoid. Shoulder arthritis is another complication reported after the Latarjet procedure, which poses additional challenges to both the surgeon and patient.

  20. Appropriateness of Diagnostic Coronary Angiography as a Measure of Cardiac Ischemia Testing in Non-Emergency Patients – A Retrospective Cross-Sectional Analysis

    PubMed Central

    Chmiel, Corinne; Reich, Oliver; Signorell, Andri; Tandjung, Ryan; Rosemann, Thomas; Senn, Oliver

    2015-01-01

    Background Adequate application of guidelines concerning non-invasive ischemia testing (NIIT) could avoid inappropriate invasive testing in non-emergency situations. Hardly any data exists regarding frequency and appropriateness of diagnostic coronary angiography (CA). The aim of this study was to evaluate the proportion and predictors of patients without NIIT prior to elective purely diagnostic CA without therapeutic intervention. Methods Retrospective cross-sectional analysis of insurance claims data from 2012 and 2013. Patients <18 years, acute cardiac ischemia and emergency procedures and patients insured in a managed care model were excluded from analysis. The proportion of patients with NIIT procedures (stress-ECG, transthoracic echocardiography, stress echocardiography, scintigraphy, computer tomography, heart MRI) undertaken within two months before diagnostic CA was assessed. Multiple logistic regression analysis was applied to investigate independent determinants for receiving NIIT. Findings 2714 patients were included for analysis. 37.5% (1018) did not receive any NIIT before CA. When high risk patients (patients having received therapeutic cardiac intervention within one month after or 18 months prior to diagnostic CA, n = 766) were excluded 34.3% (669) did not receive NIIT before CA. High risk status as well as >6 chronic comorbidities were independently associated with a lower proportion of NIIT (p<0.0001, OR 0.607 and p = 0.0041, OR 0.648), when additionally controlled for age, sex, language area, insurance coverage, inpatient treatment, cardiovascular medication and lower number of chronic comorbidities. Age (p<0.05, OR 1.009) and intake of oral antiplatelet therapy (p<0.0001, OR 1.914) were independently associated with a higher proportion of NIIT when controlled for the mentioned cofactors. Conclusions Our data show that despite the existence of guidelines a substantial overuse of a potentially harmful and inappropriate diagnostic intervention is

  1. Diagnostic Oligonucleotide Microarray Fingerprinting of Bacillus Isolates

    SciTech Connect

    Chandler, Darrell P.; Alferov, Oleg; Chernov, Boris; Daly, Don S.; Golova, Julia; Perov, Alexander N.; Protic, Miroslava; Robison, Richard; Shipma, Matthew; White, Amanda M.; Willse, Alan R.

    2006-01-01

    A diagnostic, genome-independent microbial fingerprinting method using DNA oligonucleotide microarrays was used for high-resolution differentiation between closely related Bacillus strains, including two strains of Bacillus anthracis that are monomorphic (indistinguishable) via amplified fragment length polymorphism fingerprinting techniques. Replicated hybridizations on 391-probe nonamer arrays were used to construct a prototype fingerprint library for quantitative comparisons. Descriptive analysis of the fingerprints, including phylogenetic reconstruction, is consistent with previous taxonomic organization of the genus. Newly developed statistical analysis methods were used to quantitatively compare and objectively confirm apparent differences in microarray fingerprints with the statistical rigor required for microbial forensics and clinical diagnostics. These data suggest that a relatively simple fingerprinting microarray and statistical analysis method can differentiate between species in the Bacillus cereus complex, and between strains of B. anthracis. A synthetic DNA standard was used to understand underlying microarray and process-level variability, leading to specific recommendations for the development of a standard operating procedure and/or continued technology enhancements for microbial forensics and diagnostics.

  2. Procedures for numerical analysis of circadian rhythms

    PubMed Central

    REFINETTI, ROBERTO; LISSEN, GERMAINE CORNÉ; HALBERG, FRANZ

    2010-01-01

    This article reviews various procedures used in the analysis of circadian rhythms at the populational, organismal, cellular and molecular levels. The procedures range from visual inspection of time plots and actograms to several mathematical methods of time series analysis. Computational steps are described in some detail, and additional bibliographic resources and computer programs are listed. PMID:23710111

  3. 21 CFR 640.120 - Alternative procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Alternative procedures. 640.120 Section 640.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Alternative Procedures §...

  4. Diagnostics for first plasma and development plan on KSTAR

    SciTech Connect

    Lee, J. H.; Na, H. K.; Lee, S. G.; Bak, J. G.; Seo, D. C.; Seo, S. H.; Oh, S. T.; Ko, W. H.; Chung, J.; Nam, Y. U.; Lee, K. D.; Ka, E. M.; Oh, Y. K.; Kwon, M.; Jeong, S. H.

    2010-06-15

    The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

  5. Public Sector Impasse Procedures.

    ERIC Educational Resources Information Center

    Vadakin, James C.

    The subject of collective bargaining negotiation impasse procedures in the public sector, which includes public school systems, is a broad one. In this speech, the author introduces the various procedures, explains how they are used, and lists their advantages and disadvantages. Procedures discussed are mediation, fact-finding, arbitration,…

  6. Prosthetic procedure for simultaneous immediate loading of opposing edentulous arches.

    PubMed

    Biscaro, Leonello; Ferlin, Paolo; Becattelli, Alberto; Vigolo, Paolo

    2014-10-01

    For patients with complete edentulism, a significant problem is the transfer of diagnostic data to the definitive casts when an immediate loading technique is used. This article presents a prosthetic procedure to allow simultaneous treatment of opposing edentulous arches with immediate implant loading. This technique uses 2 occlusal acrylic resin devices to transfer the diagnostic cast information to the definitive casts. Esthetic and functional fixed dental prostheses are fabricated from diagnostic information acquired in the presurgical phase without any impression or recording of the maxillomandibular relationship during or after surgery. This methodology is applicable when the simultaneous immediate loading of implants in 2 edentulous arches is indicated.

  7. Unique passive diagnostic for slapper detonators

    NASA Technical Reports Server (NTRS)

    Brigham, William P.; Schwartz, John J.

    1994-01-01

    The objective of this study was to find a material and configuration that could reliably detect the proper functioning of a slapper (non-explosive) detonator. Because of the small size of the slapper geometry (on the order of a 15 mils), most diagnostic techniques are not suitable. This program has the additional requirements that the device would be used on centrifuge so that it could not use any electrical power or output signals. This required that the diagnostic be completely passive. The paper describes the three facets of the development effort: complete characterization of the slapper using VISAR measurements, selection of the diagnostic material and configuration, and testing of the prototype designs. The VISAR testing required that use of a special optical probe to allow the laser light to reach both bridges of the dual-slapper detonator. Results are given in the form of flyer velocity as a function of the initiating charge voltage level. The selected diagnostic design functions in a manner similar to a dent block except that the impact of the Kapton disk from a properly-functioning slapper causes a fracture pattern. A quick visual inspection is all that is needed to determine if the flyer velocity exceeded the threshold value. Sub-threshold velocities produce a substantially different appearance.

  8. Unique passive diagnostic for slapper detonators

    SciTech Connect

    Brigham, W.P.; Schwartz, J.J.

    1994-02-01

    The objective of this study was to find a material and configuration that could reliably detect the proper functioning of a current slapper detonator. Because of the small size of the slapper geometry (on the order of a 15 mils), most diagnostic techniques are not suitable. This program has the additional requirement that the device could not use any electrical power or output signals. This required that the diagnostic be completely passive. The paper describes the three facets of the development effort: complete characterization of the slapper using VISAR measurements, selection of the diagnostic material and configuration, and testing of the prototype designs. The VISAR testing required the use of a special optical probe to allow the laser light to reach both bridges of the slapper detonator. Results are given in the form of flyer velocity as a function of the initiating voltage level. The selected diagnostic design functions in a manner similar to a dent block except that the impact of the Kapton disk causes a fracture pattern. A quick visual inspection is all that is needed to determine if the flyer velocity exceeded the threshold value. Sub-threshold velocities produce a substantially different appearance.

  9. Diagnostics summary: Working group T9

    SciTech Connect

    Ralph J. Pasquinelli; Marc C. Ross

    2002-12-09

    The diagnostics T9 group was charged with reviewing the diagnostic requirements of the proposed accelerators for the future. The list includes the e+e- colliders, Muon Neutrino source, NLC, Proton Driver, Tesla, and the VLHC. While the machines vary widely on diagnostic requirements, there are many similarities that were discovered. The following sections will attempt to point out the similarities and requirements for R and D for these future accelerators. To answer the Charge to the group they organized joint sessions with most of the machine groups and several of the technical groups. In addition, due to their overwhelming importance, they held a special session on position monitor systems. For each of the joint machine group sessions they generated a table of required diagnostic systems, selected the highest priority items using a ranking based on need and RD effort, and pondered a RD path leading from the present state of the technology to a system satisfying the requirement. They used the joint technical group sessions to collect up to date RD plans and to assess the applicability of new ideas in a broad range of topics. As required by their Charge, they have also tried to include promising new ideas.

  10. [Safety of food additives in Japan].

    PubMed

    Ito, Sumio

    2011-01-01

    Recently, many accidents relating to food happened in Japan. The consumer's distrust for food, food companies, and the administration is increasing. The consumer especially has an extreme refusal feeling for chemicals such as food additives and agricultural chemicals, and begins to request agricultural chemical-free vegetables and food additive-free food. Food companies also state no agricultural chemicals and no food additives to correspond with consumers' request and aim at differentiating. The food additive is that the Ministry of Health, Labour and Welfare specifies the one that person's health might not be ruined by providing for Food Sanitation Law Article 10 in our country. The standard for food additives and standard for use of food additives are provided according to regulations of Food Sanitation Law Article 11. Therefore, it is thought that the food additive used is safe now. Then, it reports on the procedure and the safety examination, etc. in our country for designation for food additive this time.

  11. Current procedural terminology; a primer.

    PubMed

    Hirsch, Joshua A; Leslie-Mazwi, Thabele M; Nicola, Gregory N; Barr, Robert M; Bello, Jacqueline A; Donovan, William D; Tu, Raymond; Alson, Mark D; Manchikanti, Laxmaiah

    2015-04-01

    In 1966, The American Medical Association (AMA) working with multiple major medical specialty societies developed an iterative coding system for describing medical procedures and services using uniform language, the Current Procedural Terminology (CPT) system. The current code set, CPT IV, forms the basis of reporting most of the services performed by healthcare providers, physicians and non-physicians as well as facilities allowing effective, reliable communication among physician and other providers, third parties and patients. This coding system and its maintenance has evolved significantly since its inception, and now goes well beyond its readily perceived role in reimbursement. Additional roles include administrative management, tracking new and investigational procedures, and evolving aspects of 'pay for performance'. The system also allows for local, regional and national utilization comparisons for medical education and research. Neurointerventional specialists use CPT category I codes regularly--for example, 36,215 for first-order cerebrovascular angiography, 36,216 for second-order vessels, and 37,184 for acute stroke treatment by mechanical means. Additionally, physicians add relevant modifiers to the CPT codes, such as '-26' to indicate 'professional charge only,' or '-59' to indicate a distinct procedural service performed on the same day. PMID:24589819

  12. Developing policies and procedures.

    PubMed

    Randolph, Susan A

    2006-11-01

    The development of policies and procedures is an integral part of the occupational health nurse's role. Policies and procedures serve as the foundation for the occupational health service and are based on its vision, mission, culture, and values. The design and layout selected for the policies and procedures should be simple, consistent, and easy to use. The same format should be used for all existing and new policies and procedures. Policies and procedures should be reviewed periodically based on a specified time frame (i.e., annually). However, some policies may require a more frequent review if they involve rapidly changing external standards, ethical issues, or emerging exposures. PMID:17124968

  13. Diagnostics and Microelectronics

    SciTech Connect

    Balch, J.W.

    1993-03-01

    This report discusses activities of the Diagnostics and Microelectronics thrust area which conducts activities in semiconductor devices and semiconductor fabrication technology for programs at Lawrence Livermore National Laboratory. Our multidisciplinary engineering and scientific staff use modern computational tools and semi-conductor microfabrication equipment to develop high-performance devices. Our work concentrates on three broad technologies of semiconductor microdevices: (1) silicon on III-V semiconductor microeletronics, (2) lithium niobate-based and III-V semiconductor-based photonics, and (3) silicon-based micromaching for application to microstructures and microinstruments. In FY-92, we worked on projects in seven areas, described in this report: novel photonic detectors; a wideband phase modulator; an optoelectronic terahertz beam system; the fabrication of microelectrode electrochemical sensors; diamond heatsinks; advanced micromachining technologies; and electrophoresis using silicon microchannels.

  14. Diagnostic evaluation of rhabdomyolysis.

    PubMed

    Nance, Jessica R; Mammen, Andrew L

    2015-06-01

    Rhabdomyolysis is characterized by severe acute muscle injury resulting in muscle pain, weakness, and/or swelling with release of myofiber contents into the bloodstream. Symptoms develop over hours to days after an inciting factor and may be associated with dark pigmentation of the urine. Serum creatine kinase and urine myoglobin levels are markedly elevated. Clinical examination, history, laboratory studies, muscle biopsy, and genetic testing are useful tools for diagnosis of rhabdomyolysis, and they can help differentiate acquired from inherited causes of rhabdomyolysis. Acquired causes include substance abuse, medication or toxic exposures, electrolyte abnormalities, endocrine disturbances, and autoimmune myopathies. Inherited predisposition to rhabdomyolysis can occur with disorders of glycogen metabolism, fatty acid β-oxidation, and mitochondrial oxidative phosphorylation. Less common inherited causes of rhabdomyolysis include structural myopathies, channelopathies, and sickle-cell disease. This review focuses on the differentiation of acquired and inherited causes of rhabdomyolysis and proposes a practical diagnostic algorithm. Muscle Nerve 51: 793-810, 2015. PMID:25678154

  15. Rig Diagnostic Tools

    NASA Technical Reports Server (NTRS)

    Soileau, Kerry M.; Baicy, John W.

    2008-01-01

    Rig Diagnostic Tools is a suite of applications designed to allow an operator to monitor the status and health of complex networked systems using a unique interface between Java applications and UNIX scripts. The suite consists of Java applications, C scripts, Vx- Works applications, UNIX utilities, C programs, and configuration files. The UNIX scripts retrieve data from the system and write them to a certain set of files. The Java side monitors these files and presents the data in user-friendly formats for operators to use in making troubleshooting decisions. This design allows for rapid prototyping and expansion of higher-level displays without affecting the basic data-gathering applications. The suite is designed to be extensible, with the ability to add new system components in building block fashion without affecting existing system applications. This allows for monitoring of complex systems for which unplanned shutdown time comes at a prohibitive cost.

  16. Peritoneal tuberculosis: diagnostic options.

    PubMed Central

    Lal, N; Soto-Wright, V

    1999-01-01

    BACKGROUND: Extrapulmonary tuberculosis has vague symptoms and few signs. It is essential to recognize and diagnose this curable disease prior to performing definitive surgery. Newer tests such as DNA or RNA amplification allow for early diagnosis but have limitations. CASE: We report a case of peritoneal tuberculosis in an immigrant woman. She had vague symptoms of low-grade fever, mild abdominal pain, obstipation, and bloating. Diagnostic laparoscopy was performed to establish the diagnosis. Tuberculosis was confirmed by DNA extraction from the frozen section specimen with subsequent analysis using polymerase chain reaction. CONCLUSION: Peritoneal tuberculosis is a disease that often simulates malignancies. With the increasing prevalence of human immunodeficiency virus in developed countries, tuberculosis is also on the rise and should be considered in the differential diagnosis of a patient with an abdominal/pelvic mass and ascites. PMID:10524670

  17. Diagnostic Evaluation of Rhabdomyolysis

    PubMed Central

    Nance, Jessica R.; Mammen, Andrew L.

    2015-01-01

    Rhabdomyolysis is characterized by severe acute muscle injury resulting in muscle pain, weakness, and/or swelling with release of myofiber contents into the bloodstream. Symptoms develop over hours to days following an inciting factor and may be associated with dark pigmentation of the urine. Serum creatine kinase and urine myoglobin levels are markedly elevated. The clinical examination, history, laboratory studies, muscle biopsy, and genetic testing are useful tools for diagnosis of rhabdomyolysis, and they can help differentiate acquired from inherited causes of rhabdomyolysis. Acquired causes include substance abuse, medication or toxic exposures, electrolyte abnormalities, endocrine disturbance, and autoimmune myopathies. Inherited predisposition to rhabdomyolysis can occur with disorders of glycogen metabolism, fatty acid beta-oxidation, and mitochondrial oxidative phosphorylation. Less common inherited causes of rhabdomyolysis include structural myopathies, channelopathies, and sickle cell disease. This review focuses on the differentiation of acquired and inherited causes of rhabdomyolysis and proposes a practical diagnostic algorithm. PMID:25678154

  18. Diagnostic and vaccine chapter.

    PubMed

    Wolfram, J H; Kokanov, S K; Verkhovsky, O A

    2010-10-01

    The first report in this chapter describes the development of a killed composite vaccine. This killed vaccine is non-infectious to humans, other animals, and the environment. The vaccine has low reactivity, is non-abortive, and does not induce pathomorphological alterations to the organs of vaccinated animals. The second report of this chapter describes the diagnostic value of a competitive enzyme-linked immunosorbent assay for detecting Brucella-specific antibodies and its ability to discriminate vaccinated cattle from infected cattle. The results indicated that the competitive enzyme-linked immunosorbent assay is more sensitive than traditional tests for detecting antibodies to Brucella abortus in naturally and experimentally infected cattle. PMID:20850688

  19. Identification of factors associated with diagnostic error in primary care

    PubMed Central

    2014-01-01

    Background Missed, delayed or incorrect diagnoses are considered to be diagnostic errors. The aim of this paper is to describe the methodology of a study to analyse cognitive aspects of the process by which primary care (PC) physicians diagnose dyspnoea. It examines the possible links between the use of heuristics, suboptimal cognitive acts and diagnostic errors, using Reason’s taxonomy of human error (slips, lapses, mistakes and violations). The influence of situational factors (professional experience, perceived overwork and fatigue) is also analysed. Methods Cohort study of new episodes of dyspnoea in patients receiving care from family physicians and residents at PC centres in Granada (Spain). With an initial expected diagnostic error rate of 20%, and a sampling error of 3%, 384 episodes of dyspnoea are calculated to be required. In addition to filling out the electronic medical record of the patients attended, each physician fills out 2 specially designed questionnaires about the diagnostic process performed in each case of dyspnoea. The first questionnaire includes questions on the physician’s initial diagnostic impression, the 3 most likely diagnoses (in order of likelihood), and the diagnosis reached after the initial medical history and physical examination. It also includes items on the physicians’ perceived overwork and fatigue during patient care. The second questionnaire records the confirmed diagnosis once it is reached. The complete diagnostic process is peer-reviewed to identify and classify the diagnostic errors. The possible use of heuristics of representativeness, availability, and anchoring and adjustment in each diagnostic process is also analysed. Each audit is reviewed with the physician responsible for the diagnostic process. Finally, logistic regression models are used to determine if there are differences in the diagnostic error variables based on the heuristics identified. Discussion This work sets out a new approach to studying the

  20. An overview of nuclear medicine imaging procedures.

    PubMed

    Hogg, Peter; Lawson, Richard

    2015-11-25

    Nuclear medicine imaging is not generally well understood by nurses who work outside this area. Consequently, nurses can find themselves unable to answer patients' questions about nuclear medicine imaging procedures or give them proper information before they attend for a test. This article aims to explain what is involved in some common diagnostic nuclear medicine imaging procedures so that nurses are able to discuss this with patients. It also addresses some common issues about radiation protection that nurses might encounter in their usual working routine. The article includes links to videos showing some typical nuclear medicine imaging procedures from a patient's point of view and links to an e-Learning for Healthcare online resource that provides detailed information for nurses.

  1. Aesthetic Surgical Crown Lengthening Procedure.

    PubMed

    de Oliveira, Pablo Santos; Chiarelli, Fabio; Rodrigues, José A; Shibli, Jamil A; Zizzari, Vincenzo Luca; Piattelli, Adriano; Iezzi, Giovanna; Perrotti, Vittoria

    2015-01-01

    The aim of this case report was to describe the surgical sequence of crown lengthening to apically reposition the dentogingival complex, in addition to an esthetic restorative procedure. Many different causes can be responsible for short clinical crown. In these cases, the correct execution of a restorative or prosthetic rehabilitation requires an increasing of the crown length. According to the 2003 American Academy of Periodontology (Practice Profile Survey), crown lengthening is the most habitual surgical periodontal treatment.

  2. Aesthetic Surgical Crown Lengthening Procedure

    PubMed Central

    de Oliveira, Pablo Santos; Chiarelli, Fabio; Rodrigues, José A.; Shibli, Jamil A.; Zizzari, Vincenzo Luca; Piattelli, Adriano; Iezzi, Giovanna; Perrotti, Vittoria

    2015-01-01

    The aim of this case report was to describe the surgical sequence of crown lengthening to apically reposition the dentogingival complex, in addition to an esthetic restorative procedure. Many different causes can be responsible for short clinical crown. In these cases, the correct execution of a restorative or prosthetic rehabilitation requires an increasing of the crown length. According to the 2003 American Academy of Periodontology (Practice Profile Survey), crown lengthening is the most habitual surgical periodontal treatment. PMID:26609452

  3. 24 CFR 10.12 - Additional rulemaking proceedings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Additional rulemaking proceedings. 10.12 Section 10.12 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development RULEMAKING: POLICY AND PROCEDURES Procedures § 10.12 Additional rulemaking proceedings. The Secretary may invite interested...

  4. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Fletcher, James C. (Inventor); Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1992-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  5. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1993-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of the additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  6. Diagnostic Imaging of Dental Disease in Pet Rabbits and Rodents.

    PubMed

    Capello, Vittorio

    2016-09-01

    Diagnostic imaging techniques are of paramount importance for dentistry and oral disorders of rabbits, rodents, and other exotic companion mammals. Aside from standard radiography, stomatoscopy is a complementary tool allowing a thorough and detailed inspection of the oral cavity. Computed tomography (CT) generates multiple 2-dimensional views and 3-dimensional reconstructions providing superior diagnostic accuracy also useful for prognosis and treatment of advanced dental disease and its related complications. MRI is a diagnostic imaging technique additional to CT used primarily to enhance soft tissues, including complex odontogenic abscesses.

  7. Additional Types of Neuropathy

    MedlinePlus

    ... A A Listen En Español Additional Types of Neuropathy Charcot's Joint Charcot's Joint, also called neuropathic arthropathy, ... can stop bone destruction and aid healing. Cranial Neuropathy Cranial neuropathy affects the 12 pairs of nerves ...

  8. Food Additives and Hyperkinesis

    ERIC Educational Resources Information Center

    Wender, Ester H.

    1977-01-01

    The hypothesis that food additives are causally associated with hyperkinesis and learning disabilities in children is reviewed, and available data are summarized. Available from: American Medical Association 535 North Dearborn Street Chicago, Illinois 60610. (JG)

  9. Smog control fuel additives

    SciTech Connect

    Lundby, W.

    1993-06-29

    A method is described of controlling, reducing or eliminating, ozone and related smog resulting from photochemical reactions between ozone and automotive or industrial gases comprising the addition of iodine or compounds of iodine to hydrocarbon-base fuels prior to or during combustion in an amount of about 1 part iodine per 240 to 10,000,000 parts fuel, by weight, to be accomplished by: (a) the addition of these inhibitors during or after the refining or manufacturing process of liquid fuels; (b) the production of these inhibitors for addition into fuel tanks, such as automotive or industrial tanks; or (c) the addition of these inhibitors into combustion chambers of equipment utilizing solid fuels for the purpose of reducing ozone.

  10. Constructing empirical resolution diagnostics for kriging and minimum curvature gridding

    NASA Astrophysics Data System (ADS)

    Chiao, Ling-Yun; Chen, Ying-Nien; Gung, Yuancheng

    2014-05-01

    Resolution analysis is a crucial appraisal procedure in solving general estimation problems, especially for correctly interpreting the results of spatial analysis schemes. Resolution analyses based on the resolving kernels are typically applied to small inverse problems only when the inverse operators are explicitly accessible. Stochastic simulation schemes have been proposed to extract empirical resolution information for solving large inverse problem. In this study, we generalize the formulation of the empirical resolution length and derive the characteristic length of the point spread function for general estimation methods such as minimum curvature gridding and kriging interpolation schemes that are not equipped with explicitly accessible resolving kernels. The implementation of these resolution diagnostics has not been possible in the past and is demonstrated in this study to facilitate clarifying the advantages and limitations of these widely used methods. In addition, we compare these schemes, based on the resolution appraisal, with a multiscale gridding algorithm in the spatial analysis of the Pacific seafloor heat flow observations. By depicting the pattern of the resolution length variations of both the empirical averaging function and the point spread function for each of the estimated models, we demonstrate that schemes equipped with multiscale capability are more favorable for accommodating sparse, nonuniform data distribution than stationary schemes, such as the kriging method. Furthermore, the empirical resolution pattern constructed in this study facilitates the selection of an appropriate reference function and radii of influence for fitting the variogram, which is difficult but critical when using the kriging method.

  11. Diagnostic of fusion neutrons on JET tokamak using diamond detector

    NASA Astrophysics Data System (ADS)

    Nemtsev, G.; Amosov, V.; Marchenko, N.; Meshchaninov, S.; Rodionov, R.; Popovichev, S.; JET EFDA contributors

    2014-08-01

    In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

  12. Diagnostic of fusion neutrons on JET tokamak using diamond detector

    SciTech Connect

    Nemtsev, G.; Amosov, V.; Marchenko, N.; Meshchaninov, S.; Rodionov, R.; Popovichev, S.; Collaboration: JET EFDA Conbributors

    2014-08-21

    In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

  13. Progress of development of Thomson scattering diagnostic system on COMPASS

    SciTech Connect

    Bilkova, P.; Melich, R.; Aftanas, M.; Boehm, P.; Sestak, D.; Jares, D.; Weinzettl, V.; Stoeckel, J.; Hron, M.; Panek, R.; Walsh, M. J.

    2010-10-15

    A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

  14. 33 CFR 203.83 - Additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Additional requirements. 203.83 Section 203.83 Navigation and Navigable Waters CORPS OF ENGINEERS, DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE EMERGENCY EMPLOYMENT OF ARMY AND OTHER RESOURCES, NATURAL DISASTER PROCEDURES Local...

  15. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  16. Nonequilibrium diagnostics of plasma thrusters

    SciTech Connect

    Eddy, T.L.; Grandy, J.D.

    1990-01-01

    This paper describes possible techniques by which the state of plasma thruster operation for space propulsion can be determined from a minimum set of experimental data in the laboratory. The kinetic properties of the nonequilibrium plasma plume usually can not be directly related to the observed radiation; hence, appropriate nonequilibrium diagnostic techniques must be employed. A newly developed multithermal, multichemical equilibrium method is discussed that uses measured line emission intensities and N equations to solve for N unknowns. The effect of arbitrarily changing the number of selected N unknowns and how one determines the optimum (minimum) number to be used for a given composition is also presented. The chemical nonequilibrium aspects and the application to molecular species have not yet been published. The important conclusions are that (1) complete thermodynamic systems in nonequilibrium can be described by relatively few variables if appropriate choices and filtering methods are used, (2) a few radiation measurements can yield valid kinetic properties, and (3) the major question in the relations to be used is in the form of the law of mass action. The results are substantiated in the laboratory by additional alternative methods of measurement of some of the kinetic properties. 13 refs., 1 fig.

  17. Dual Processing and Diagnostic Errors

    ERIC Educational Resources Information Center

    Norman, Geoff

    2009-01-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical,…

  18. Saliva as a diagnostic fluid.

    PubMed

    Streckfus, C F; Bigler, L R

    2002-03-01

    In the last 10 years, the use of saliva as a diagnostic fluid has become somewhat of a translational research success story. Technologies are now available enabling saliva to be used to diagnose disease and predict disease progression. This review describes some important recent advances in salivary diagnostics and barriers to application and advancement. This review will also stimulate future research activity.

  19. Student Interpretations of Diagnostic Feedback

    ERIC Educational Resources Information Center

    Doe, Christine

    2015-01-01

    Diagnostic assessment is increasingly being recognized as a potentially beneficial tool for teaching and learning (Jang, 2012). There have been calls in the research literature for students to receive diagnostic feedback and for researchers to investigate how such feedback is used by students. Therefore, this study examined how students…

  20. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  1. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  2. Main challenges for ITER optical diagnostics

    SciTech Connect

    Vukolov, K. Yu.; Orlovskiy, I. I.; Alekseev, A. G.; Borisov, A. A.; Andreenko, E. N.; Kukushkin, A. B.; Lisitsa, V. S.; Neverov, V. S.

    2014-08-21

    The review is made of the problems of ITER optical diagnostics. Most of these problems will be related to the intensive neutron radiation from hot plasma. At a high level of radiation loads the most types of materials gradually change their properties. This effect is most critical for optical diagnostics because of degradation of optical glasses and mirrors. The degradation of mirrors, that collect the light from plasma, basically will be induced by impurity deposition and (or) sputtering by charge exchange atoms. Main attention is paid to the search of glasses for vacuum windows and achromatic lens which are stable under ITER irradiation conditions. The last results of irradiation tests in nuclear reactor of candidate silica glasses KU-1, KS-4V and TF 200 are presented. An additional problem is discussed that deals with the stray light produced by multiple reflections from the first wall of the intense light emitted in the divertor plasma.

  3. Automated diagnostic kiosk for diagnosing diseases

    DOEpatents

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  4. Main challenges for ITER optical diagnostics

    NASA Astrophysics Data System (ADS)

    Vukolov, K. Yu.; Orlovskiy, I. I.; Alekseev, A. G.; Borisov, A. A.; Andreenko, E. N.; Kukushkin, A. B.; Lisitsa, V. S.; Neverov, V. S.

    2014-08-01

    The review is made of the problems of ITER optical diagnostics. Most of these problems will be related to the intensive neutron radiation from hot plasma. At a high level of radiation loads the most types of materials gradually change their properties. This effect is most critical for optical diagnostics because of degradation of optical glasses and mirrors. The degradation of mirrors, that collect the light from plasma, basically will be induced by impurity deposition and (or) sputtering by charge exchange atoms. Main attention is paid to the search of glasses for vacuum windows and achromatic lens which are stable under ITER irradiation conditions. The last results of irradiation tests in nuclear reactor of candidate silica glasses KU-1, KS-4V and TF 200 are presented. An additional problem is discussed that deals with the stray light produced by multiple reflections from the first wall of the intense light emitted in the divertor plasma.

  5. Diagnostics For Recirculating And Energy Recovered Linacs

    SciTech Connect

    Geoffrey A. Krafft; Jean-Claude Denard

    2002-12-18

    In this paper, the electron beam diagnostics developed for recirculating electron accelerators will be reviewed. The main novelties in dealing with such accelerators are: to have sufficient information and control possibilities for the longitudinal phase space, to have means to accurately set the recirculation path length, and to have a means to distinguish the beam passes on measurements of position in the linac proper. The solutions to these problems obtained at Jefferson Laboratory and elsewhere will be discussed. In addition, more standard instrumentation (profiling and emittance measurements) will be reviewed in the context of recirculating linacs. Finally, and looking forward, electron beam diagnostics for applications to high current energy recovered linacs will be discussed.

  6. Piezo-sensor self-diagnostics using electrical impedance measurements.

    SciTech Connect

    Park, G. H.; Farrar, C. R.; Rutherford, A. C.; Robertson, A. N.

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  7. Diagnostic Errors Study Findings

    MedlinePlus

    ... ahrq.gov/professionals/quality-patient-safety/quality-resources/tools/office-testing-toolkit/ . Additionally, the Office of the National ... Assistance on Health Initiatives Measurement & Reporting Tools Research Tools & ... Centers & Programs Centers & Offices Initiatives About AHRQ Portfolios ...

  8. Patient dose monitoring in Dubai in radiography and interventional procedures.

    PubMed

    AlSuwaidi, J S; AlMazrouei, N K; Pottybindu, S; Siraj, M; Mathew, D; Al Blooshi, A A; Kuriakose, V P

    2015-06-01

    This paper presents ongoing actions in Dubai on patient dose monitoring in digital radiographic examinations, mammography, interventional procedures, and dental radiological procedures. The aim of Dubai Health Authority (DHA) is to move towards the establishment of local diagnostic reference levels. DHA has participated in national and regional projects under the umbrella of the International Atomic Energy Agency. The need for local radiation protection educational programmes and wider patient dosimetry monitoring and recording emerged from this work.

  9. Additive Manufacturing Infrared Inspection

    NASA Technical Reports Server (NTRS)

    Gaddy, Darrell

    2014-01-01

    Additive manufacturing is a rapid prototyping technology that allows parts to be built in a series of thin layers from plastic, ceramics, and metallics. Metallic additive manufacturing is an emerging form of rapid prototyping that allows complex structures to be built using various metallic powders. Significant time and cost savings have also been observed using the metallic additive manufacturing compared with traditional techniques. Development of the metallic additive manufacturing technology has advanced significantly over the last decade, although many of the techniques to inspect parts made from these processes have not advanced significantly or have limitations. Several external geometry inspection techniques exist such as Coordinate Measurement Machines (CMM), Laser Scanners, Structured Light Scanning Systems, or even traditional calipers and gages. All of the aforementioned techniques are limited to external geometry and contours or must use a contact probe to inspect limited internal dimensions. This presentation will document the development of a process for real-time dimensional inspection technique and digital quality record of the additive manufacturing process using Infrared camera imaging and processing techniques.

  10. Candidate CDTI procedures study

    NASA Technical Reports Server (NTRS)

    Ace, R. E.

    1981-01-01

    A concept with potential for increasing airspace capacity by involving the pilot in the separation control loop is discussed. Some candidate options are presented. Both enroute and terminal area procedures are considered and, in many cases, a technologically advanced Air Traffic Control structure is assumed. Minimum display characteristics recommended for each of the described procedures are presented. Recommended sequencing of the operational testing of each of the candidate procedures is presented.

  11. Focal masses in a non-cirrhotic liver: The additional benefit of CEUS over baseline imaging.

    PubMed

    Chiorean, L; Cantisani, V; Jenssen, C; Sidhu, P S; Baum, U; Dietrich, C F

    2015-09-01

    Incidentally detected focal liver lesions are commonly encountered in clinical practice presenting a challenge in the daily department work flow. Guidelines for the management of incidental focal liver lesions have been published but comments, illustrations and recommendations regarding practical issues are crucial. The unique features of contrast-enhanced ultrasound in non-invasive assessment of focal liver lesion enhancement throughout the vascular phases in real-time has allowed an impressive improvement in the diagnostic accuracy of ultrasound. We highlight the additional benefit of contrast-enhanced ultrasound over conventional B-mode ultrasound imaging in detection, characterization, differential and final diagnosis of focal liver lesions, as well as for liver metastases screening. The current roles of cross-sectional imaging are explained in detail, with indications and limitations for each procedure. The advantages of CEUS, such as non-ionizing radiation exposure, cost benefits, non-iodinate contrast agents, and repeatability are also described ultimately improving patient management.

  12. Diagnostic accuracy of the Whooley questions for the identification of depression: a diagnostic meta-analysis

    PubMed Central

    Bosanquet, Katharine; Bailey, Della; Gilbody, Simon; Harden, Melissa; Manea, Laura; Nutbrown, Sarah; McMillan, Dean

    2015-01-01

    Objectives To determine the diagnostic accuracy of the Whooley questions in the identification of depression; and, to examine the effect of an additional ‘help’ question. Design Systematic review with random effects bivariate diagnostic meta-analysis. Search strategies included electronic databases, examination of reference lists, and forward citation searches. Inclusion criteria Studies were included that provided sufficient data to calculate the diagnostic accuracy of the Whooley questions against a gold standard diagnosis of major depression. Data extraction Descriptive information, methodological quality criteria, and 2×2 contingency tables were extracted. Results Ten studies met inclusion criteria. Pooled sensitivity was 0.95 (95% CI 0.88 to 0.97) and pooled specificity was 0.65 (95% CI 0.56 to 0.74). Heterogeneity was low (I2=24.1%). Primary care subgroup analysis gave broadly similar results. Four of the ten studies provided information on the effect of an additional help question. The addition of this question did not consistently improve specificity while retaining high sensitivity as reported in the original validation study. Conclusions The two-item Whooley questions have high sensitivity and modest specificity in the detection of depression. The current evidence for the use of an additional help question is not consistent and there is, as yet, insufficient data to recommend its use for screening or case finding. Trial registration number CRD42014009695. PMID:26656018

  13. The tissue diagnostic instrument.

    PubMed

    Hansma, Paul; Yu, Hongmei; Schultz, David; Rodriguez, Azucena; Yurtsev, Eugene A; Orr, Jessica; Tang, Simon; Miller, Jon; Wallace, Joseph; Zok, Frank; Li, Cheng; Souza, Richard; Proctor, Alexander; Brimer, Davis; Nogues-Solan, Xavier; Mellbovsky, Leonardo; Peña, M Jesus; Diez-Ferrer, Oriol; Mathews, Phillip; Randall, Connor; Kuo, Alfred; Chen, Carol; Peters, Mathilde; Kohn, David; Buckley, Jenni; Li, Xiaojuan; Pruitt, Lisa; Diez-Perez, Adolfo; Alliston, Tamara; Weaver, Valerie; Lotz, Jeffrey

    2009-05-01

    Tissue mechanical properties reflect extracellular matrix composition and organization, and as such, their changes can be a signature of disease. Examples of such diseases include intervertebral disk degeneration, cancer, atherosclerosis, osteoarthritis, osteoporosis, and tooth decay. Here we introduce the tissue diagnostic instrument (TDI), a device designed to probe the mechanical properties of normal and diseased soft and hard tissues not only in the laboratory but also in patients. The TDI can distinguish between the nucleus and the annulus of spinal disks, between young and degenerated cartilage, and between normal and cancerous mammary glands. It can quantify the elastic modulus and hardness of the wet dentin left in a cavity after excavation. It can perform an indentation test of bone tissue, quantifying the indentation depth increase and other mechanical parameters. With local anesthesia and disposable, sterile, probe assemblies, there has been neither pain nor complications in tests on patients. We anticipate that this unique device will facilitate research on many tissue systems in living organisms, including plants, leading to new insights into disease mechanisms and methods for their early detection.

  14. [Diagnostic imaging of lying].

    PubMed

    Lass, Piotr; Sławek, Jarosław; Sitek, Emilia; Szurowska, Edyta; Zimmermann, Agnieszka

    2013-01-01

    Functional diagnostic imaging has been applied in neuropsychology for more than two decades. Nowadays, the functional magnetic resonance (fMRI) seems to be the most important technique. Brain imaging in lying has been performed and discussed since 2001. There are postulates to use fMRI for forensic purposes, as well as commercially, e.g. testing the loyalty of employees, especially because of the limitations of traditional polygraph in some cases. In USA fMRI is performed in truthfulness/lying assessment by at least two commercial companies. Those applications are a matter of heated debate of practitioners, lawyers and specialists of ethics. The opponents of fMRI use for forensic purposes indicate the lack of common agreement on it and the lack of wide recognition and insufficient standardisation. Therefore it cannot serve as a forensic proof, yet. However, considering the development of MRI and a high failure rate of traditional polygraphy, forensic applications of MRI seem to be highly probable in future. PMID:23888745

  15. The tissue diagnostic instrument

    PubMed Central

    Hansma, Paul; Yu, Hongmei; Schultz, David; Rodriguez, Azucena; Yurtsev, Eugene A.; Orr, Jessica; Tang, Simon; Miller, Jon; Wallace, Joseph; Zok, Frank; Li, Cheng; Souza, Richard; Proctor, Alexander; Brimer, Davis; Nogues-Solan, Xavier; Mellbovsky, Leonardo; Peña, M. Jesus; Diez-Ferrer, Oriol; Mathews, Phillip; Randall, Connor; Kuo, Alfred; Chen, Carol; Peters, Mathilde; Kohn, David; Buckley, Jenni; Li, Xiaojuan; Pruitt, Lisa; Diez-Perez, Adolfo; Alliston, Tamara; Weaver, Valerie; Lotz, Jeffrey

    2009-01-01

    Tissue mechanical properties reflect extracellular matrix composition and organization, and as such, their changes can be a signature of disease. Examples of such diseases include intervertebral disk degeneration, cancer, atherosclerosis, osteoarthritis, osteoporosis, and tooth decay. Here we introduce the tissue diagnostic instrument (TDI), a device designed to probe the mechanical properties of normal and diseased soft and hard tissues not only in the laboratory but also in patients. The TDI can distinguish between the nucleus and the annulus of spinal disks, between young and degenerated cartilage, and between normal and cancerous mammary glands. It can quantify the elastic modulus and hardness of the wet dentin left in a cavity after excavation. It can perform an indentation test of bone tissue, quantifying the indentation depth increase and other mechanical parameters. With local anesthesia and disposable, sterile, probe assemblies, there has been neither pain nor complications in tests on patients. We anticipate that this unique device will facilitate research on many tissue systems in living organisms, including plants, leading to new insights into disease mechanisms and methods for their early detection. PMID:19485522

  16. Gonorrhoea diagnostics: An update.

    PubMed

    Verma, R; Sood, S

    2016-01-01

    Diagnosis of gonorrhoea is an ongoing challenge. The organism is fastidious requiring meticulous collection and transport for successful cultivation. Asymptomatic infections are common which go undetected by conventional methods thereby leading to continued transmission and the risk of complications. The nucleic acid amplification tests, now increasingly used in developed countries, offer improved sensitivity compared to bacterial culture. However, these continue to suffer sequence related problems leading to false positive and false negative results. Further, these cannot be used for generation of data on antibiotic susceptibility because genetic markers of antibiotic resistance to recommended therapies have not been fully characterised. They are unaffordable in a setting like ours where reliance is placed on syndromic approach for sexually transmitted infection (STI) management. The use of syndromic approach has resulted in a considerable decline in the number of Neisseria gonorrhoeae isolates that have been cultured for diagnostic purposes. Many laboratories formerly doing so are no longer performing culture for gonococci, and the basic skills have been lost. There is a need to not only revive this skill but also adopt newer technologies that can aid in accurate diagnosis in a cost-effective manner. There is room for innovation that can facilitate the development of a point-of-care test for this bacterial STI. PMID:27080763

  17. The tissue diagnostic instrument

    NASA Astrophysics Data System (ADS)

    Hansma, Paul; Yu, Hongmei; Schultz, David; Rodriguez, Azucena; Yurtsev, Eugene A.; Orr, Jessica; Tang, Simon; Miller, Jon; Wallace, Joseph; Zok, Frank; Li, Cheng; Souza, Richard; Proctor, Alexander; Brimer, Davis; Nogues-Solan, Xavier; Mellbovsky, Leonardo; Peña, M. Jesus; Diez-Ferrer, Oriol; Mathews, Phillip; Randall, Connor; Kuo, Alfred; Chen, Carol; Peters, Mathilde; Kohn, David; Buckley, Jenni; Li, Xiaojuan; Pruitt, Lisa; Diez-Perez, Adolfo; Alliston, Tamara; Weaver, Valerie; Lotz, Jeffrey

    2009-05-01

    Tissue mechanical properties reflect extracellular matrix composition and organization, and as such, their changes can be a signature of disease. Examples of such diseases include intervertebral disk degeneration, cancer, atherosclerosis, osteoarthritis, osteoporosis, and tooth decay. Here we introduce the tissue diagnostic instrument (TDI), a device designed to probe the mechanical properties of normal and diseased soft and hard tissues not only in the laboratory but also in patients. The TDI can distinguish between the nucleus and the annulus of spinal disks, between young and degenerated cartilage, and between normal and cancerous mammary glands. It can quantify the elastic modulus and hardness of the wet dentin left in a cavity after excavation. It can perform an indentation test of bone tissue, quantifying the indentation depth increase and other mechanical parameters. With local anesthesia and disposable, sterile, probe assemblies, there has been neither pain nor complications in tests on patients. We anticipate that this unique device will facilitate research on many tissue systems in living organisms, including plants, leading to new insights into disease mechanisms and methods for their early detection.

  18. Molecular diagnostics in genodermatoses.

    PubMed

    Schaffer, Julie V

    2012-12-01

    In recent years, there has been tremendous progress in elucidating the molecular bases of genodermatoses. The interface between genetics and dermatology has broadened with the identification of "new" heritable disorders, improved recognition of phenotypic spectrums, and integration of molecular and clinical data to simplify disease categorization and highlight relationships between conditions. With the advent of next-generation sequencing and other technological advances, dermatologists have promising new tools for diagnosis of genodermatoses. This article first addresses phenotypic characterization and classification with the use of online databases, considering concepts of clinical and genetic heterogeneity. Indications for genetic testing related to medical care and patient/family decision making are discussed. Standard genetic testing is reviewed, including resources for finding specialized laboratories, methods of gene analysis, and patient/family counseling. The benefits and challenges associated with multigene panels, array-based analysis (eg, copy number variation, linkage, and homozygosity), and whole-exome or whole-genome sequencing are then examined. Specific issues relating to molecular analysis of mosaic skin conditions and prenatal/preimplantation diagnosis are also presented. Use of the modern molecular diagnostics described herein enhance our ability to counsel, monitor, and treat patients and families affected by genodermatoses, with broader benefits of providing insights into cutaneous physiology and multifactorial skin disorders.

  19. Phenylethynyl Containing Reactive Additives

    NASA Technical Reports Server (NTRS)

    Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor)

    2002-01-01

    Phenylethynyl containing reactive additives were prepared from aromatic diamine, containing phenylethvnvl groups and various ratios of phthalic anhydride and 4-phenylethynviphthalic anhydride in glacial acetic acid to form the imide in one step or in N-methyl-2-pvrrolidinone to form the amide acid intermediate. The reactive additives were mixed in various amounts (10% to 90%) with oligomers containing either terminal or pendent phenylethynyl groups (or both) to reduce the melt viscosity and thereby enhance processability. Upon thermal cure, the additives react and become chemically incorporated into the matrix and effect an increase in crosslink density relative to that of the host resin. This resultant increase in crosslink density has advantageous consequences on the cured resin properties such as higher glass transition temperature and higher modulus as compared to that of the host resin.

  20. Comparative analyses of plasma probe diagnostics techniques

    SciTech Connect

    Godyak, V. A.; Alexandrovich, B. M.

    2015-12-21

    The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.