Science.gov

Sample records for additional diagnostic procedures

  1. Diagnostic procedures in immunodermatology.

    PubMed

    Cormane, R H; Asghar, S S

    1976-07-01

    gold or radiolabeled glucosamine. In contact allergic dermatitis, an increase in the IgD-bearing lymphocytes and granulocytes has also been correlated with cellular hypersensitivity. Lymphocytes and polymorphonuclear leukocytes coated with antibodies mainly directed against nuclear antigens of the basal layer cells of the noninvolved epidermis have invariably been encountered in psoriasis. The use of these findings for diagnostic purposes and for understanding the mechanisms of certain diseases is being explored.

  2. Diagnostic procedures for osteoporosis in the elderly.

    PubMed

    Delmas, P D

    1995-01-01

    Several recent studies show that bone loss continues in the elderly, and that various regimens are still effective in the elderly to stop bone loss. Thus, diagnostic procedures for osteoporosis should be considered in elderly women, i.e. measurement of bone mass by dual energy X-ray absorptiometry of the hip, spine or forearm that have been shown to predict the subsequent risk of fractures. The rate of bone turnover, and therefore of bone loss, is quite variable from patient to patient and can be assessed with improved sensitivity and specificity with the new markers that are specific for bone formation and bone resorption.

  3. Diagnostic Procedures to Detect Chlamydia trachomatis Infections

    PubMed Central

    Meyer, Thomas

    2016-01-01

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections. PMID:27681919

  4. Diagnostic Procedures to Detect Chlamydia trachomatis Infections.

    PubMed

    Meyer, Thomas

    2016-08-05

    The intracellular life style of chlamydia and the ability to cause persistent infections with low-grade replication requires tests with high analytical sensitivity to directly detect C. trachomatis (CT) in medical samples. Nucleic acid amplification tests (NAATs) are the most sensitive assays with a specificity similar to cell culture and are considered the method of choice for CT detection. In addition, NAATs can be performed on various clinical specimens that do not depend on specific transport and storage conditions, since NAATs do not require infectious bacteria. In the case of lower genital tract infections, first void urine and vaginal swabs are the recommended specimens for testing males and females, respectively. Infections of anorectal, oropharyngeal and ocular epithelia should also be tested by NAAT analysis of corresponding mucosal swabs. In particular, anorectal infections of men who have sex with men (MSM) should include evaluation of lymphogranuloma venereum (LGV) by identification of genotypes L1, L2 or L3. Detection of CT antigens by enzyme immunoassay (EIAs) or rapid diagnostic tests (RDTs) are unsuitable due to insufficient sensitivity and specificity. Recent PCR-based RDTs, however, are non-inferior to standard NAATs, and might be used at the point-of-care. Serology finds application in the diagnostic work-up of suspected chronic CT infection but is inappropriate to diagnose acute infections.

  5. Cancer Risks Associated with External Radiation From Diagnostic Imaging Procedures

    PubMed Central

    Linet, Martha S.; Slovis, Thomas L.; Miller, Donald L.; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; de Gonzalez, Amy Berrington

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate widespread use of evidence-based appropriateness criteria for decisions about imaging procedures, oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives, development of electronic lifetime records of imaging procedures for patients and their physicians, and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. PMID:22307864

  6. Cancer risks associated with external radiation from diagnostic imaging procedures.

    PubMed

    Linet, Martha S; Slovis, Thomas L; Miller, Donald L; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; Berrington de Gonzalez, Amy

    2012-01-01

    The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but increased potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate the widespread use of evidence-based appropriateness criteria for decisions about imaging procedures; oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives; development of electronic lifetime records of imaging procedures for patients and their physicians; and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures.

  7. Unproven diagnostic procedures in IgE-mediated allergic diseases.

    PubMed

    Niggemann, B; Grüber, C

    2004-08-01

    A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.

  8. Dynamic diagnostic and decision procedures under uncertainty

    SciTech Connect

    Baranov, V.V.

    1995-01-01

    In this paper, we consider uncertainty that arises when the true state x {element_of} E is not accessible to direct observation and remains unknown. Instead, we observe some features {theta} {element_of} {Theta} that carry a certain information about the true state. This information is described by the conditional distribution P({Theta}{vert_bar}E), which we call the linkage distribution. Regarding this distribution we assume that it exists but is unknown. This leads to uncertainty with respect to states from E and the linkage distribution P({Theta}{vert_bar}E), which we denote by NEP. The substantive problem can be stated as follows: from observations of the features {theta}{element_of}{Theta} made at each time instant n = 1,2,...,recognize the state x {element_of} E, identify the linkage distribution P, and use the results of recognition and identification to choose a decision y {element_of} Y so that the decision process is optimal in some sense. State recognition is the subject of diagnostics. The uncertainty NEP thus generates a problem of diagnostics and dynamic decision making.

  9. Peritoneal lavage and other diagnostic procedures in blunt abdominal trauma

    SciTech Connect

    Burney, R.E.

    1986-08-01

    Diagnostic procedures such as peritoneal lavage, computed tomography, emergency angiography, nuclear scintigraphy, and contrast studies of the gastrointestinal and urinary tracts can assist in the identification, quantification, and localization of injury after blunt abdominal trauma. Use of these procedures should be determined by careful clinically assessment as part of an aggressive approach to the diagnosis of the injured patient. 22 references.

  10. Cardiovascular procedures/diagnostic techniques and therapeutic procedures

    SciTech Connect

    Tilkian, A.G.; Daily, E.K.

    1986-01-01

    This book covers the technical and therapeutic aspects of cardiovascular procedures in immense detail. There are large and appropriate diagrams and tables. The topics of the chapters are tools for catheterization, venous access, arterial access, hemodynamic monitoring, cardiac catheterization and coronary arteriography, ergonovine provocation testing for coronary artery spasm, pulmonary angiography, endomyocredial biopsy, electrophysiologic studies, pericardiocentesis and drainage, intraaortic balloon pumping, direct current cardioversion and defibrilaltion, pacemaker implantation of the automatic implantable cardioverter/defibrillator, coronary angioplasty, thrombolytic therapy, transluminal catheter extraction and resolution of intracardiac catheter knots, cardiopulmonary resuscitation, contrast media toxicity and allergic reactions, radiation hazards, and medicolegal concerns. An appendix and index follow these chapters. In general, each chapter covers historical aspects, indications, complications, techniques, and preoperative and postoperative care.

  11. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  12. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  13. 10 CFR 590.310 - Opportunity for additional procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Opportunity for additional procedures. 590.310 Section 590.310 Energy DEPARTMENT OF ENERGY (CONTINUED) NATURAL GAS (ECONOMIC REGULATORY ADMINISTRATION) ADMINISTRATIVE PROCEDURES WITH RESPECT TO THE IMPORT AND EXPORT OF NATURAL GAS Procedures § 590.310...

  14. Diagnostic procedures for submucosal tumors in the gastrointestinal tract

    PubMed Central

    Ponsaing, Laura Graves; Kiss, Katalin; Loft, Annika; Jensen, Lise Ingemann; Hansen, Mark Berner

    2007-01-01

    This review is part one of three, which will present an update on diagnostic procedures for gastrointestinal (GI) submucosal tumors (SMTs). Part two identifies the classification and part three the therapeutic methods regarding GI SMTs. Submucosal tumors are typically asymptomatic and therefore encountered incidentally. Advances in diagnostic tools for gastrointestinal submucosal tumors have emerged over the past decade. The aim of this paper is to provide the readers with guidelines for the use of diagnostic procedures, when a submucosal tumor is suspected. Literature searches were performed to find information on diagnostics for gastrointestinal submucosal tumors. Based on the searches, the optimal diagnostic procedures and specific features of the submucosal tumors could be outlined. Standard endoscppy, capsule endoscopy and push-and-pull enteroscopy (PPE) together with barium contrast X-ray do not alone provide sufficient information, when examining submucosal tumors. Endoscopic ultrasound (EUS), computed tomography (CT), magnetic resonance imaging (MRI) and fluorodeoxyglucose-labeled positron emission tomography (FDG-PET) are recommended as supplementary tools. PMID:17659668

  15. 40 CFR 85.2222 - Onboard diagnostic test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Tests § 85.2222 Onboard diagnostic test procedures. The test sequence for the OBD inspection shall consist of the following steps: (a) The OBD inspection shall be conducted with the key-on/engine running... Mode $01, PID $01 request in accordance with 40 CFR 86.1806 to determine the OBD evaluation status....

  16. Diagnostic Procedures for Detecting Nonlinear Relationships between Latent Variables

    ERIC Educational Resources Information Center

    Bauer, Daniel J.; Baldasaro, Ruth E.; Gottfredson, Nisha C.

    2012-01-01

    Structural equation models are commonly used to estimate relationships between latent variables. Almost universally, the fitted models specify that these relationships are linear in form. This assumption is rarely checked empirically, largely for lack of appropriate diagnostic techniques. This article presents and evaluates two procedures that can…

  17. 5 CFR 179.309 - Additional administrative procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Additional administrative procedures. 179.309 Section 179.309 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.309 Additional administrative procedures....

  18. Overview of the impact of noninvasive prenatal testing on diagnostic procedures.

    PubMed

    Warsof, Steven L; Larion, Sebastian; Abuhamad, Alfred Z

    2015-10-01

    Noninvasive prenatal testing (NIPT) has had a profound influence in the field of prenatal diagnosis since the 1997 discovery of cell-free fetal DNA in maternal blood. Research has progressed rapidly, with clinical data supporting laboratory studies showing that NIPT is highly sensitive and specific for fetal aneuploidy, resulting in marked uptake in the high-risk patient population. The superior accuracy of NIPT compared with conventional screening methods has led to significant decreases in the number of invasive diagnostic procedures, in addition to a concomitant decrease in the number of procedure-related fetal losses. Yet, NIPT has been described as a 'disruptive innovation' due to the considerable changes the technology has commanded on current prenatal screening and diagnostic practices. This review summarizes both institutional and global experience with NIPT uptake, its effect on reducing diagnostic invasive procedures, and the unique challenges that reduced procedural volume may have on physician and trainee proficiency, cytogenetic laboratories, and neonatal outcome.

  19. Developments in the diagnostic procedures for von Willebrand disease.

    PubMed

    De Jong, A; Eikenboom, J

    2016-03-01

    Von Willebrand disease (VWD) is the most common inherited bleeding disorder but its diagnosis can be challenging due to the heterogeneity of the disease. VWD is mainly associated with mild mucocutaneous bleeding, although there are more severe phenotypes with bleeding from the gastrointestinal tract or even the joints. Also, surgical interventions and trauma may lead to critical bleeding events. These bleeding episodes are all related to quantitative or qualitative defects of von Willebrand factor (VWF), a multimeric glycoprotein produced by endothelial cells and megakaryocytes, which mediates platelet adhesion and aggregation and binds factor VIII (FVIII) in the circulation. This review describes the diagnostic procedures required for correct diagnosis. Accurate diagnosis and classification is required for proper treatment and counseling. Assessment of bleeding starts with the medical history. After a positive bleeding or family history, subsequent laboratory investigations will start with a panel of standard screening tests for hemostatic defects. Patients suspected of having VWD will be tested for plasma VWF antigen levels, the ability of VWF to bind platelets and FVIII activity. When VWD is confirmed, a set of subtyping tests can classify the patients as VWD types 1, 2 (A, B, M or N) or 3. The performance of some additional assays and analyses, such as VWF propeptide measurement or genetic analysis, may help in identifying the pathological mechanism behind certain defects or can guide in the choice of treatment.

  20. Clonal complexity in Mycobacterium tuberculosis can hamper diagnostic procedures.

    PubMed

    Pérez-Lago, Laura; Herranz, Marta; Navarro, Yurena; Ruiz Serrano, María Jesús; Miralles, Pilar; Bouza, Emilio; García-de-Viedma, Darío

    2017-02-15

    Clonal complexity is increasingly accepted in Mycobacterium tuberculosis infection, including mixed infections by ≥2 strains, which usually occur in settings with a high burden of tuberculosis and/or a high risk of overexposure to infected patients. Mixed infections can hamper diagnostic procedures: obtaining an accurate antibiogram is difficult when the susceptibility patterns of the strains differ. Here, we show how mixed infections can also prove challenging for other diagnostic procedures, even outside settings where mixed infections are traditionally expected. We show how an unnoticed mixed infection in an HIV-positive patient diagnosed in Madrid, Spain, with differences in the representativeness of the coinfecting strains in different sputum samples, markedly complicated the resolution of a laboratory cross-contamination false-positivity alert.

  1. Ventilation of neck breathers undergoing a diagnostic procedure or surgery.

    PubMed

    Brook, Itzhak

    2012-06-01

    Receiving sedation while undergoing a diagnostic procedure or general anesthesia for surgery is challenging for neck breathers including laryngectomees. Unfortunately, most medical personnel including nurses, medical technicians, surgeons, and anesthesiologists caring for laryngectomees before, during, and after surgery are not familiar with their unique anatomy, how they speak, and how to manage their airways during and after the operation. Methods to improve the care are discussed. Educating medical personnel about these issues can improve the care of neck breathers.

  2. Enzyme immunoassays and related procedures in diagnostic medical virology

    PubMed Central

    Kurstak, Edouard; Tijssen, Peter; Kurstak, Christine; Morisset, Richard

    1986-01-01

    This review article describes several applications of the widely used enzyme immunoassay (EIA) procedure. EIA methods have been adapted to solve problems in diagnostic virology where sensitivity, specificity, or practicability is required. Concurrent developments in hybridoma and conjugation methods have increased significantly the use of these assays. A general overview of EIA methods is given together with typical examples of their use in diagnostic medical virology; attention is drawn to possible pitfalls. Recent advances in recombinant DNA technology have made it possible to produce highly specific nucleic acid probes that have a sensitivity approximately 100 times greater than that of EIA. Some applications of these probes are described. Although the non-labelled nucleic acid probes for use in the field are not as refined as non-labelled immunoassays, their range of applications is expected to expand rapidly in the near future. ImagesFig. 4 PMID:3533302

  3. Test Procedure - pumping system for caustic addition project

    SciTech Connect

    Leshikar, G.A.

    1994-10-01

    This test procedure provides the requirements for sub-system testing and integrated operational testing of the submersible mixer pump and caustic addition equipment by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E).

  4. Neonatal Cholestasis – Differential Diagnoses, Current Diagnostic Procedures, and Treatment

    PubMed Central

    Götze, Thomas; Blessing, Holger; Grillhösl, Christian; Gerner, Patrick; Hoerning, André

    2015-01-01

    Cholestatic jaundice in early infancy is a complex diagnostic problem. Misdiagnosis of cholestasis as physiologic jaundice delays the identification of severe liver diseases. In the majority of infants, prolonged physiologic jaundice represent benign cases of breast milk jaundice, but few among them are masked and caused by neonatal cholestasis (NC) that requires a prompt diagnosis and treatment. Therefore, a prolonged neonatal jaundice, longer than 2 weeks after birth, must always be investigated because an early diagnosis is essential for appropriate management. To rapidly identify the cases with cholestatic jaundice, the conjugated bilirubin needs to be determined in any infant presenting with prolonged jaundice at 14 days of age with or without depigmented stool. Once NC is confirmed, a systematic approach is the key to reliably achieve the diagnosis in order to promptly initiate the specific, and in many cases, life-saving therapy. This strategy is most important to promptly identify and treat infants with biliary atresia, the most common cause of NC, as this requires a hepatoportoenterostomy as soon as possible. Here, we provide a detailed work-up approach including initial treatment recommendations and a clinically oriented overview of possible differential diagnoses in order to facilitate the early recognition and a timely diagnosis of cholestasis. This approach warrants a broad spectrum of diagnostic procedures and investigations including new methods that are described in this review. PMID:26137452

  5. Galactography: the diagnostic procedure of choice for nipple discharge

    SciTech Connect

    Tabar, L.; Dean, P.B.; Pentek, Z.

    1983-10-01

    Galactogrpahy was performed in 204 women with a nipple discharge and the secretion confirmed histopathologically. All 116 intraductal tumors (papilloma, papillomatosis, carcinoma), which were associated with a serous or bloody discharge, were detected preoperatively. A palpable mass had little diagnostic significance, and exfoliative cytology was positive in only 11% (2/18) of the patients with carcinoma. The authors recommend that all patients with a spontaneous bloody or serous discharge from a single lactiferous orifice undergo galactography in addition to physical, cytological, and mammographic examination. Intraductal injection of methylene blue dye will demonstrate the affected duct system to the surgeon and can often make surgery less radical or even unnecessary.

  6. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  7. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  8. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  9. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  10. 42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of this section— (i) Radiology services include diagnostic and therapeutic radiology, nuclear medicine, CAT scan procedures, magnetic resonance imaging, ultrasound and other imaging services; and...

  11. Eating Disorder Diagnostic Scale: Additional Evidence of Reliability and Validity

    ERIC Educational Resources Information Center

    Stice, Eric; Fisher, Melissa; Martinez, Erin

    2004-01-01

    The authors conducted 4 studies investigating the reliability and validity of the Eating Disorder Diagnostic Scale (HDDS; E. Stice, C. F. Telch, & S. L. Rizvi, 2000), a brief self-report measure for diagnosing anorexia nervosa, bulimia nervosa, and binge eating disorder. Study 1 found that the HDDS showed criterion validity with interview-based…

  12. Delaying diagnostic procedure significantly increases mortality in patients with invasive mucormycosis.

    PubMed

    Jeong, Su Jin; Lee, Ji Un; Song, Young Goo; Lee, Kyoung Hwa; Lee, Min Joo

    2015-12-01

    Invasive mucormycosis is an uncommon but increasing life-threatening fungal infection. The present study investigated clinical characteristics and mortality among patients diagnosed as invasive mucormycosis infection. We retrospectively reviewed a total of 24 histologically proven cases of invasive mucormycosis at two tertiary care referral hospitals between November 2005 and February 2014. Overall survival was 50% (n = 12). The time between onset of symptom and diagnostic procedure proved to be associated with mortality (P = 0.009). In addition, preexisting renal failure and thrombocytopenia demonstrated trends toward a poor outcome in our study (P = 0.089 and 0.065, respectively). On multivariate regression analysis, delayed diagnostic procedure (more than 16 days after the onset of symptoms) was an independent predictor of mortality (OR= 12.34, 95% CI, 1.43-10.64; P = 0.022). Mucormycosis is a destructive fungal infection that is associated with high mortality rates, ranging from 40% to 100% depending on the form of disease. When a clinician suspects invasive mucormycosis infection, an early diagnostic procedure performed within 16 days from the onset of symptom and early initiation of antifungal therapy will lead to successful management of this highly fatal disease.

  13. Optimized and Automated design of Plasma Diagnostics for Additive Manufacture

    NASA Astrophysics Data System (ADS)

    Stuber, James; Quinley, Morgan; Melnik, Paul; Sieck, Paul; Smith, Trevor; Chun, Katherine; Woodruff, Simon

    2016-10-01

    Despite having mature designs, diagnostics are usually custom designed for each experiment. Most of the design can be now be automated to reduce costs (engineering labor, and capital cost). We present results from scripted physics modeling and parametric engineering design for common optical and mechanical components found in many plasma diagnostics and outline the process for automated design optimization that employs scripts to communicate data from online forms through proprietary and open-source CAD and FE codes to provide a design that can be sent directly to a printer. As a demonstration of design automation, an optical beam dump, baffle and optical components are designed via an automated process and printed. Supported by DOE SBIR Grant DE-SC0011858.

  14. Broken rotor bars detection by a new non-invasive diagnostic procedure

    NASA Astrophysics Data System (ADS)

    Eltabach, Mario; Antoni, Jerome; Shanina, Galyna; Sieg-Zieba, Sophie; Carniel, Xavier

    2009-05-01

    A new technique of diagnosing data for broken rotor bars in induction motors derived from two of the three stator currents, the Beirut diagnostic procedure (BDP) is presented in this paper. The theoretical principles directly related to the application of this diagnostic technique are described, emphasizing the use of a severity factor in order to evaluate the extension of the fault. Defining the severity factor as the normalized amplitude of the fault characteristic frequency enables us to draw up a table of comparison of several usual electric diagnostic methods. Besides the traditional one-phase current spectrum analysis, values of the severity factor related to electrical signals like the instantaneous powers, the current space vector modulus and finally related to the new Beirut diagnostic method are analyzed with respect to the variation of the power factor angle and of the sum of the two current side-band angular displacement. The BDP offers several advantages over the usual motor current signature analyses (MCSA) methods: it is shown how the proposed severity factor applied to the new diagnostic technique is not dependent on motor parameters such as the power factor angle and the fault type which is not the case of the instantaneous powers. In addition, the BDP has the advantage of detecting easily fault characteristic frequencies, which is not possible via diagnostic methods that use the detection of two side-band components as in the simple current spectrum. By theoretical analysis, computer simulations, and laboratory experiments, it is shown that the new method enhances the reliability of diagnostics of broken rotor bars in induction motor.

  15. 78 FR 20103 - Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... AGENCY Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures AGENCY..., on Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures. This document is Federal Guidance Report No. 14. It replaces Federal Guidance Report No. 9, ``Radiation Protection...

  16. An Additional Step in the Guided Lecture Procedure.

    ERIC Educational Resources Information Center

    Toole, Robert J.

    2000-01-01

    Describes the Guided Lecture Procedure (GLP), a procedure that requires students to suspend all notetaking and listen carefully during an approximately 20-minute lecture, followed by an active notetaking and small group interaction phase. Adds one extra requirement in the active notetaking phase: requiring each learner to write a question for the…

  17. Effects on Diagnostic Parameters After Removing Additional Synchronous Gear Meshes

    NASA Technical Reports Server (NTRS)

    Decker, Harry J.

    2003-01-01

    Gear cracks are typically difficult to diagnose with sufficient time before catastrophic damage occurs. Significant damage must be present before algorithms appear to be able to detect the damage. Frequently there are multiple gear meshes on a single shaft. Since they are all synchronous with the shaft frequency, the commonly used synchronous averaging technique is ineffective in removing other gear mesh effects. Carefully applying a filter to these extraneous gear mesh frequencies can reduce the overall vibration signal and increase the accuracy of commonly used vibration metrics. The vibration signals from three seeded fault tests were analyzed using this filtering procedure. Both the filtered and unfiltered vibration signals were then analyzed using commonly used fault detection metrics and compared. The tests were conducted on aerospace quality spur gears in a test rig. The tests were conducted at speeds ranging from 2500 to 5000 revolutions per minute and torques from 184 to 228 percent of design load. The inability to detect these cracks with high confidence results from the high loading which is causing fast fracture as opposed to stable crack growth. The results indicate that these techniques do not currently produce an indication of damage that significantly exceeds experimental scatter.

  18. Diagnostic Models for Procedural Bugs in Basic Mathematics Skills.

    ERIC Educational Resources Information Center

    Brown, John Seely; Burton, Richard R.

    A new diagnostic modeling system for automatically synthesizing a deep structure model of a student's misconceptions or bugs in his/her basic mathematics skills provides a mechanism for explaining why a student is making a mistake as opposed to simply identifying the mistake. This report consists of four sections. The first provides examples of…

  19. Refining Diagnostic Procedures for Adults With Symptoms of ADHD.

    PubMed

    Sibley, Margaret H; Coxe, Stefany; Molina, Brooke S G

    2017-04-01

    Attention deficit/hyperactivity disorder (ADHD) is a chronic disorder that afflicts individuals into adulthood. The field continues to refine diagnostic standards for ADHD in adults, complicated by the disorder's heterogeneous presentation, subjective symptoms, and overlap with other disorders. Two key diagnostic questions are from whom to collect diagnostic information and which symptoms should be contained on an adult diagnostic checklist. Using a trifactor model, Martel et al. examine these questions in a sample of adults with and without self-identified ADHD symptoms. In this response, we highlight the importance of their finding that self and informant symptom reports differ in a sample of adults who acknowledge ADHD symptoms. We also review issues that continue to face the field related to model specification, evaluating symptom utility, and sample composition, discussing how these issues influence conclusions that may be drawn from Martel et al. and similar investigations. We conclude that the article makes an important research contribution about the nature of self and informant ADHD symptom reports but emphasize that symptom checklist refinement must occur through a broad lens that considers work from a range of sample types and clinically informative analytic strategies.

  20. Model-Based Assurance of Diagnostic Procedures for Complex Systems

    DTIC Science & Technology

    2010-10-01

    this knowledge for fault detection and isolation . In parallel developments, different communities have found value in analytic state-based models...that are used for fault detection and isolation . Figure 2. The schematic of the Electrical Power System (EPS) in the Advanced Diagnostics and

  1. Hypnosis before diagnostic or therapeutic medical procedures: a systematic review.

    PubMed

    Cheseaux, Nicole; de Saint Lager, Alix Juillet; Walder, Bernhard

    2014-01-01

    The aim of this systematic review was to estimate the efficiency of hypnosis prior to medical procedures. Different databases were analyzed to identify randomized controlled trials (RCTs) comparing hypnosis to control interventions. All RCTs had to report pain or anxiety. Eighteen RCTs with a total of 968 patients were included; study size was from 20 to 200 patients (14 RCTs ≤ 60 patients). Fourteen RCTs included 830 adults and 4 RCTs included 138 children. Twelve of 18 RCTs had major quality limitations related to unclear allocation concealments, provider's experience in hypnosis, patient's adherence to hypnotic procedures, and intention-to-treat design. This systematic review observed major methodological limitations in RCTs on hypnosis prior to medical procedures.

  2. A systematic review on diagnostic procedures for specific language impairment: The sensitivity and specificity issues

    PubMed Central

    Shahmahmood, Toktam Maleki; Jalaie, Shohreh; Soleymani, Zahra; Haresabadi, Fatemeh; Nemati, Parvin

    2016-01-01

    Background: Identification of children with specific language impairment (SLI) has been viewed as both necessity and challenge. Investigators and clinicians use different tests and measures for this purpose. Some of these tests/measures have good psychometric properties, but it is not sufficient for diagnostic purposes. A diagnostic procedure can be used for identification a specific population with confidence only when its sensitivity and specificity are acceptable. In this study, we searched for tests/measures with predefined sensitivity and specificity for identification of preschool children with SLI from their typically developing peers. Materials and Methods: A computerized search in bibliographic databases from 2000 to August 2015 was performed with the following keywords: “specific language impairment” or SLI” and “primary language impairment” or ‘PLI’ with at least one of the followings: “diagnosis,” “identification,” “accuracy,” “sensitivity,” and “specificity.” In addition, the related citations and reference lists of the selected articles were considered. Results: The results of reviewing 23 included studies show that the index measures used in studies vary in accuracy with the sensitivity ranging from 16% to 100% and the specificity ranging from 14% to 100%. Conclusion: These varieties in sensitivity and specificity of different tests/measures confirm the necessity of attention to the diagnostic power of tests/measures before their use as diagnostic tool. Further, the results indicate there are some promising tests/measures that the available evidence supports their performances in the diagnosis of SLI in preschool-aged children, yet the place of a reference standard for the diagnosis of SLI is vacant among investigations. PMID:27904612

  3. Computer-Aided Performance Training for Diagnostic and Procedural Tasks.

    ERIC Educational Resources Information Center

    Rigney, Joseph W.; And Others

    Two computer programs for computer-assisted performance training were developed to give the students the opportunity for concentrated practice of troubleshooting and procedural tasks in naval electronics. In contrast to the usual approach taken in computer-assisted instruction (CAI), these programs simulate essential aspects of devices and tasks…

  4. Surprise, p-value, s-value and a diagnostic procedure to detect not informative experiments

    NASA Astrophysics Data System (ADS)

    Recchia, Daniela R.; Ostermann, Thomas; Garcia, Jesus E.

    2016-06-01

    In this paper, examples of diverse measures of significance are studied in the frame of Neyman-Pearson hypothesis tests. A diagnostic procedure is proposed, to detect non informative experiments where the p-value procedure might fail to measure the significance of the outcome of an experiment.

  5. [An aphasic man with high fever; difficulty with diagnostic procedure].

    PubMed

    Potjewijd, J; Buijs, J

    2008-07-12

    A 73-year-old man, with known motor aphasia presented with high fever, dyspnoea, and vomiting. Only after several days it appeared that these signs were due to a sepsis as a consequence of a phlegmon of the neck, caused by an aspired part of his set of false teeth. The delay before diagnosis was due to the fact that adequate medical history taking was difficult because of the aphasia and attempts at non-verbal communication were poorly understood. The localization of the corpus alienum was a second pitfall, because it could not be visualized during physical examination or on the initial chest X-ray. The increased risk of colonization of dentures with pathogenic micro-organisms in nursing home residents may have played a role in the severe course of this infection. This case illustrates the diagnostic problems that may exist in patients who are unable to communicate adequately.

  6. [Fetus radiation doses from nuclear medicine and radiology diagnostic procedures. Potential risks and radiation protection instructions].

    PubMed

    Markou, Pavlos

    2007-01-01

    Although in pregnancy it is strongly recommended to avoid diagnostic nuclear medicine and radiology procedures, in cases of clinical necessity or when pregnancy is not known to the physician, these diagnostic procedures are to be applied. In such cases, counseling based on accurate information and comprehensive discussion about the risks of radiation exposure to the fetus should follow. In this article, estimations of the absorbed radiation doses due to nuclear medicine and radiology diagnostic procedures during the pregnancy and their possible risk effects to the fetus are examined and then discussed. Stochastic and detrimental effects are evaluated with respect to other risk factors and related to the fetus absorbed radiation dose and to the post-conception age. The possible termination of a pregnancy, due to radiation exposure is discussed. Special radiation protection instructions are given for radiation exposures in cases of possible, confirmed or unknown pregnancies. It is concluded that nuclear medicine and radiology diagnostic procedures, if not repeated during the pregnancy, are rarely an indication for the termination of pregnancy, because the dose received by the fetus is expected to be less than 100 mSv, which indicates the threshold dose for having deterministic effects. Therefore, the risk for the fetus due to these diagnostic procedures is low. However, stochastic effects are still possible but will be minimized if the radiation absorbed dose to the fetus is kept as low as possible.

  7. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  8. Diagnostic x-ray procedures and risk of leukemia, lymphoma, and multiple myeloma

    SciTech Connect

    Boice, J.D. Jr.; Morin, M.M.; Glass, A.G.; Friedman, G.D.; Stovall, M.; Hoover, R.N.; Fraumeni, J.F. Jr. )

    1991-03-13

    Exposure to diagnostic x-rays and the risk of leukemia, non-Hodgkin's lymphoma (NHL), and multiple myeloma were studied within two prepaid health plans. Adult patients with leukemia (n = 565), NHL (n = 318), and multiple myeloma (n = 208) were matched to controls (n = 1390), and over 25,000 x-ray procedures were abstracted from medical records. Dose response was evaluated by assigning each x-ray procedure a score based on estimated bone marrow dose. X-ray exposure was not associated with chronic lymphocytic leukemia, one of the few malignant conditions never linked to radiation (relative risk (RR), 0.66). For all other forms of leukemia combined (n = 358), there was a slight elevation in risk (RR, 1.17) but no evidence of a dose-response relationship when x-ray procedures near the time of diagnosis were excluded. Similarly, patients with NHL were exposed to diagnostic x-ray procedures more often than controls (RR, 1.32), but the RR fell to 0.99 when the exposure to diagnostic x-ray procedures within 2 years of diagnosis was ignored. For multiple myeloma, overall risk was not significantly high (RR, 1.14), but there was consistent evidence of increasing risk with increasing numbers of diagnostic x-ray procedures. These data suggest that persons with leukemia and NHL undergo x-ray procedures frequently just prior to diagnosis for conditions related to the development or natural history of their disease. There was little evidence that diagnostic x-ray procedures were causally associated with leukemia or NHL. The risk for multiple myeloma, however, was increased among those patients who were frequently exposed to x-rays.

  9. Diagnostic and therapeutic-restorative procedures for masticatory dysfunctions

    PubMed Central

    Freesmeyer, Wolfgang B.; Fussnegger, M. R.; Ahlers, M. O.

    2005-01-01

    Temporomandibular disorders (TMD) or craniomandibular disorders, respectively, involve diseases of the teeth and periodontia as well as the masticatory muscles, temporomandibular joints and associated structures. It has been shown in recent years that psychological, social and general medical influences are of enormous importance in the etiology of TMD in addition to anatomical, physiological, parafunctional and other biological causes. This signifies that therapists confronted with TMD should already include at an early stage other specialists such as pain therapists, neurologists, ENT physicians, psychotherapists and physiotherapists. Patients need to be referred to dentists specializing in TMD when ENT examinations yield no pathological findings. The treatment of TMD is subdivided into the following steps that are always related to underlying diagnoses: informing patients, self-observation, relaxation therapy, behavioral therapy, physiotherapy, drug therapy, therapeutic local anesthesia, splint therapy, and, if necessary, prosthetic and/or orthodontic therapy to restore a stable occlusion. PMID:22073067

  10. Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study

    PubMed Central

    Ihn, Yon Kwon; Byun, Jun Soo; Suh, Sang Hyun; Won, Yoo Dong; Lee, Deok Hee; Kim, Byung Moon; Kim, Young Soo; Jeon, Pyong; Ryu, Chang-Woo; Suh, Sang-il; Choi, Dae Seob; Choi, See Sung; Choi, Jin Wook; Chang, Hyuk Won; Lee, Jae-Wook; Kim, Sang Heum; Lee, Young Jun; Shin, Shang Hun; Lim, Soo Mee; Yoon, Woong; Jeong, Hae Woong; Han, Moon Hee

    2016-01-01

    Purpose To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). Materials and Methods We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. Results Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm2, 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm2 for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm2 for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. Conclusion Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. PMID:27621943

  11. Addition of Digital Breast Tomosynthesis to Full-Field Digital Mammography in the Diagnostic Setting: Additional Value and Cancer Detectability

    PubMed Central

    Seo, Mirinae; Kim, Sun Ah; Kim, Won Hwa; Lim, Ji He; Lee, Su Hyun; Bae, Min Sun; Koo, Hye Ryoung; Cho, Nariya; Moon, Woo Kyung

    2016-01-01

    Purpose The purpose of this study was to assess the value of adding digital breast tomosynthesis (DBT) to full-field digital mammography (FFDM) in the diagnostic workup of breast cancer and to determine which lesion variables affect cancer detectability in the combined modality. Methods Between March and May 2012, paired FFDM and DBT images were obtained from 203 women as part of a diagnostic workup for breast cancer. Images from FFDM alone, DBT alone, and DBT combined with FFDM were reviewed in separate sessions by six blinded readers. Jackknife alternative free-response receiver operating characteristic (JAFROC) figure of merit (FOM), sensitivity, and specificity were compared between the modalities. Lesion characteristics affecting the cancer detection rate when using the combined modality were also analyzed. Results Among the 203 women, 126 women had a total of 129 malignancies and 77 women had total of 77 benign lesions. The overall JAFROC FOM of the combined modality was higher than that of FFDM alone (0.827 vs. 0.775, p<0.001) and that of DBT alone was higher than that of FFDM alone (0.807 vs. 0.775, p=0.027). The overall sensitivity of the combined modality was higher than that of FFDM alone (80.0% vs. 73.2%, p<0.001) and that of DBT alone was higher than that of FFDM alone (78.3% vs. 73.2%, p=0.007). Compared to FFDM alone, the combined modality detected an additional 48 cancers. Using the combined modality, the presence of masses or microcalcifications was significantly associated with the cancer detection rate (p<0.001). Conclusion The combination of DBT with FFDM results in a higher diagnostic yield than FFDM alone. Additionally, DBT alone performs better than FFDM alone. However, even when DBT is combined with FFDM, breast cancers with no discernible masses and those lacking calcifications are difficult to detect. PMID:28053633

  12. An Example of the Application of the Assessment and Diagnostic Procedures of a Comprehensive Accountability Plan.

    ERIC Educational Resources Information Center

    Marco, Gary L.

    The assessment and diagnostic procedures of a comprehensive accountability plan were applied to several elementary schools from a large midwestern state. Pretest and posttest Word Knowledge and Reading scores from the Primary II Metropolitan Achievement Test administered in 1970-71 to third-graders were used. These data were used to compute…

  13. Additive manufacture (3d printing) of plasma diagnostic components and assemblies for fusion experiments

    NASA Astrophysics Data System (ADS)

    Sieck, Paul; Woodruff, Simon; Stuber, James; Romero-Talamas, Carlos; Rivera, William; You, Setthivoine; Card, Alexander

    2015-11-01

    Additive manufacturing (or 3D printing) is now becoming sufficiently accurate with a large range of materials for use in printing sensors needed universally in fusion energy research. Decreasing production cost and significantly lowering design time of energy subsystems would realize significant cost reduction for standard diagnostics commonly obtained through research grants. There is now a well-established set of plasma diagnostics, but these expensive since they are often highly complex and require customization, sometimes pace the project. Additive manufacturing (3D printing) is developing rapidly, including open source designs. Basic components can be printed for (in some cases) less than 1/100th costs of conventional manufacturing. We have examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques to determine costs of components and labor costs associated with getting the diagnostic to work as intended. With that information in hand, we set about optimizing the design to exploit the benefits of AM. Work performed under DOE Contract DE-SC0011858.

  14. Use and abuse of eight widely-used diagnostic procedures in clinical immunology: a WHO Memorandum*

    PubMed Central

    1981-01-01

    This Memorandum assesses eight widely-used diagnostic procedures with the aim of establishing their usefulness in patient care. For each procedure, the main methods that can be recommended at present are outlined and their pitfalls discussed. For each procedure, recommendations are made as to the clinical conditions for which the test is essential for diagnosis, the conditions for which the test will help in assessing and monitoring disease activity, and the conditions for which the test is useful for research purposes only. PMID:7032736

  15. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 3 2011-07-01 2011-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education... Additional procedures certain institutional accreditors must have. If the agency is an...

  16. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 3 2014-07-01 2014-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education... Additional procedures certain institutional accreditors must have. If the agency is an...

  17. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 3 2012-07-01 2012-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education... Additional procedures certain institutional accreditors must have. If the agency is an...

  18. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education... Additional procedures certain institutional accreditors must have. If the agency is an...

  19. 34 CFR 602.24 - Additional procedures certain institutional accreditors must have.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 3 2013-07-01 2013-07-01 false Additional procedures certain institutional accreditors must have. 602.24 Section 602.24 Education Regulations of the Offices of the Department of Education... Additional procedures certain institutional accreditors must have. If the agency is an...

  20. An Overview of Models of Speaking Performance and Its Implications for the Development of Procedural Framework for Diagnostic Speaking Tests

    ERIC Educational Resources Information Center

    Zhao, Zhongbao

    2013-01-01

    This paper aims at developing a procedural framework for the development and validation of diagnostic speaking tests. The researcher reviews the current available models of speaking performance, analyzes the distinctive features and then points out the implications for the development of a procedural framework for diagnostic speaking tests. On…

  1. Additive Manufacture (3D Printing) of Plasma Diagnostic Components and Assemblies for Fusion Experiments

    NASA Astrophysics Data System (ADS)

    Quinley, Morgan; Chun, Katherine; Melnik, Paul; Sieck, Paul; Smith, Trevor; Stuber, James; Woodruff, Simon; Romero-Talamas, Carlos; Rivera, William; Card, Alexander

    2016-10-01

    We are investigating the potential impact of additive manufacturing (3D printing) on the cost and complexity of plasma diagnostics. We present a survey of the current state-of-the-art in additive manufacture of metals, as well as the design of diagnostic components that have been optimized for and take advantage of these processes. Included among these is a set of retarding field analyzer probe heads that have been printed in tungsten with internal heat sinks and cooling channels. Finite element analysis of these probe heads shows the potential for a 750K reduction in peak temperature, allowing the probe to take data twice as often without melting. Results of the evaluation of these probe heads for mechanical strength and outgassing, as well as their use on Alcator C-Mod will be presented. Supported by DOE SBIR Grant DE-SC0011858.

  2. Activities identification for activity-based cost/management applications of the diagnostics outpatient procedures.

    PubMed

    Alrashdan, Abdalla; Momani, Amer; Ababneh, Tamador

    2012-01-01

    One of the most challenging problems facing healthcare providers is to determine the actual cost for their procedures, which is important for internal accounting and price justification to insurers. The objective of this paper is to find suitable categories to identify the diagnostic outpatient medical procedures and translate them from functional orientation to process orientation. A hierarchal task tree is developed based on a classification schema of procedural activities. Each procedure is seen as a process consisting of a number of activities. This makes a powerful foundation for activity-based cost/management implementation and provides enough information to discover the value-added and non-value-added activities that assist in process improvement and eventually may lead to cost reduction. Work measurement techniques are used to identify the standard time of each activity at the lowest level of the task tree. A real case study at a private hospital is presented to demonstrate the proposed methodology.

  3. The Role of Number Words in Preschoolers' Addition Concepts and Problem-Solving Procedures

    ERIC Educational Resources Information Center

    Patel, Pooja; Canobi, Katherine Helen

    2010-01-01

    Preschoolers' conceptual understanding and procedural skills were examined so as to explore the role of number-words and concept-procedure interactions in their additional knowledge. Eighteen three- to four-year-olds and 24 four- to five-year-olds judged commutativity and associativity principles and solved two-term problems involving number words…

  4. Risk and safety requirements for diagnostic and therapeutic procedures in allergology: World Allergy Organization Statement.

    PubMed

    Kowalski, Marek L; Ansotegui, Ignacio; Aberer, Werner; Al-Ahmad, Mona; Akdis, Mubeccel; Ballmer-Weber, Barbara K; Beyer, Kirsten; Blanca, Miguel; Brown, Simon; Bunnag, Chaweewan; Hulett, Arnaldo Capriles; Castells, Mariana; Chng, Hiok Hee; De Blay, Frederic; Ebisawa, Motohiro; Fineman, Stanley; Golden, David B K; Haahtela, Tari; Kaliner, Michael; Katelaris, Connie; Lee, Bee Wah; Makowska, Joanna; Muller, Ulrich; Mullol, Joaquim; Oppenheimer, John; Park, Hae-Sim; Parkerson, James; Passalacqua, Giovanni; Pawankar, Ruby; Renz, Harald; Rueff, Franziska; Sanchez-Borges, Mario; Sastre, Joaquin; Scadding, Glenis; Sicherer, Scott; Tantilipikorn, Pongsakorn; Tracy, James; van Kempen, Vera; Bohle, Barbara; Canonica, G Walter; Caraballo, Luis; Gomez, Maximiliano; Ito, Komei; Jensen-Jarolim, Erika; Larche, Mark; Melioli, Giovanni; Poulsen, Lars K; Valenta, Rudolf; Zuberbier, Torsten

    2016-01-01

    One of the major concerns in the practice of allergy is related to the safety of procedures for the diagnosis and treatment of allergic disease. Management (diagnosis and treatment) of hypersensitivity disorders involves often intentional exposure to potentially allergenic substances (during skin testing), deliberate induction in the office of allergic symptoms to offending compounds (provocation tests) or intentional application of potentially dangerous substances (allergy vaccine) to sensitized patients. These situations may be associated with a significant risk of unwanted, excessive or even dangerous reactions, which in many instances cannot be completely avoided. However, adverse reactions can be minimized or even avoided if a physician is fully aware of potential risk and is prepared to appropriately handle the situation. Information on the risk of diagnostic and therapeutic procedures in allergic diseases has been accumulated in the medical literature for decades; however, except for allergen specific immunotherapy, it has never been presented in a systematic fashion. Up to now no single document addressed the risk of the most commonly used medical procedures in the allergy office nor attempted to present general requirements necessary to assure the safety of these procedures. Following review of available literature a group of allergy experts within the World Allergy Organization (WAO), representing various continents and areas of allergy expertise, presents this report on risk associated with diagnostic and therapeutic procedures in allergology and proposes a consensus on safety requirements for performing procedures in allergy offices. Optimal safety measures including appropriate location, type and required time of supervision, availability of safety equipment, access to specialized emergency services, etc. for various procedures have been recommended. This document should be useful for allergists with already established practices and experience as well

  5. Patient Radiation Dose in Diagnostic and Interventional Procedures for Intracranial Aneurysms: Experience at a Single Center

    PubMed Central

    Chun, Chang Woo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong-Sam

    2014-01-01

    Objective To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. Materials and Methods We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Results Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 ± 44.8 Gy-cm2, and 251 ± 49 frames for diagnostic procedures, 52.9 minutes, 226.0 ± 129.2 Gy-cm2, and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 ± 184.6 Gy-cm2, and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 ± 3.2 Gy-cm2. On average, rotational angiography was used 1.4 ± 0.6 times/session (range, 1-4; n = 580). Conclusion Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level. PMID:25469098

  6. Gene technology in medical diagnostics and criminal procedure and liability for malpractice in Germany.

    PubMed

    Deutsch, E; Füllmich, R; Poppe, H

    1990-01-01

    The increasing employment of gene technological procedures in medical diagnostics and criminal procedure has forced both the medical and the legal professions to focus their attention on the complex question of liability of physicians, lab technicians, and other personnel involved in applying these measures. This article gives an outline, by citing practical cases, of the major aspects of liability for malpractice that are relevant under German law. Bearing in mind that this article will be read predominantly by members of the Anglo-American common-law legal system, the legal aspects - even though they are German legal aspects - are viewed in the light of the common law. The article examines three major issues: (a) liability for diagnoses employing gene technological procedures: (b) liability for wrong testimony based on 'genetic finger-printing': and (c) the donor's rights concerning his or her DNA-probe.

  7. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  8. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  9. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  10. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  11. 40 CFR 75.75 - Additional ozone season calculation procedures for special circumstances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Additional ozone season calculation... § 75.75 Additional ozone season calculation procedures for special circumstances. (a) The owner or operator of a unit that is required to calculate ozone season heat input for purposes of providing...

  12. Activity based costing of diagnostic procedures at a nuclear medicine center of a tertiary care hospital

    PubMed Central

    Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha

    2014-01-01

    Context: Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. Aim: The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. Materials and Methods: A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. Results: The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. Conclusion: ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments. PMID:25400363

  13. Triggering radiation alarm at security checks. Patients should be informed even after diagnostic nuclear medicine procedures.

    PubMed

    Palumbo, Barbara; Neumann, Irmgard; Havlik, Ernst; Palumbo, Renato; Sinzinger, Helmut

    2009-01-01

    During the last few years an increasing number of nuclear medicine patients in various countries evoked a radiation alarm after therapeutic or diagnostic procedures, and even after passive exposure. A prospective calculation of activity retention in the patient's body is difficult due to extremely high variation of uptake and kinetics. Furthermore, different sensitivities and distances of the detectors make a prospective calculation even more difficult. In this article a number of cases are being reported, related problems are discussed and the surprisingly very limited literature reviewed. In order to minimize problems after eventually triggering alarms, we strongly recommend that each patient receives a certificate providing personal data, tracer, dose, half-life of the radionuclide, type and date of procedure applied as well as the nuclear medicine unit to contact for further information. Furthermore, a closer cooperation and exchange of information between the authorities and local nuclear medicine societies, would be welcome.

  14. The Australian experiment: the use of evidence based medicine for the reimbursement of surgical and diagnostic procedures (1998–2004)

    PubMed Central

    O'Malley, Sue P

    2006-01-01

    Background In 1998 a formal process using the criteria of safety, effectiveness and cost-effectiveness (evidence based medicine) on the introduction and use of new medical procedures was implemented in Australia. As part of this process an expert panel, the Medical Services Advisory Committee (MSAC) was set up. This paper examines the effectiveness of this process based on the original criteria, that is, evidence based medicine. Method The data for this analysis was sourced primarily from that made available in the public domain. The MSAC web site provided Minutes from MSAC meetings; Annual Reports; Assessment and Review reports; Progress status; and Archived material. Results The total number of applications submitted to the MSAC has been relatively low averaging approximately only fourteen per year. Additionally, the source of applications has quickly shifted to the medical devices, equipment and diagnostic industry as being the major source of applications. An overall average time for the processing of an application is eighteen months. Negative recommendations were in most cases based on insufficient clinical evidence rather than clinical evidence that clearly demonstrated a lack of clinical effectiveness. It was rare for a recommendation, either positive or negative, to be based on cost-effectiveness. Conclusion New medical procedures are often the result of a process of experimentation rather than formally conducted research. Affordability and the question of who should pay for the generation, collection and analysis of the clinical evidence is perhaps the most difficult to answer. This is especially the case where the new procedure is the result of a process of experimentation with an old procedure. A cost-effective way needs to be found to collect acceptable levels of evidence proving the clinical effectiveness of these new procedures, otherwise the formal processes of evaluation such as that used by the Australian MSAC since 1998 will continue to run the

  15. Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey

    PubMed Central

    Cavdar, Iffet; Seven, Mehmet; Uslu, Lebriz; Yeyin, Nami; Tanyildizi, Handan; Abuqbeitah, Mohammad; Acikgoz, A. Serdar; Tuten, Abdullah; Demir, Mustafa

    2015-01-01

    Objective We intended to calculate approximate fetal doses in pregnant women who underwent diagnostic radiology procedures and to evaluate the safety of their pregnancies. Materials and Methods We contacted hospitals in different cities in Turkey where requests for fetal dose calculation are usually sent. Fetal radiation exposure was calculated for 304 cases in 218 pregnant women with gestational ages ranging from 5 days to 19 weeks, 2 days. FetDose software (ver. 4.0) was used in fetal dose calculations for radiographic and computed tomography (CT) procedures. The body was divided into three zones according to distance from the fetus. The first zone consisted of the head area, the lower extremities below the knee, and the upper extremities; the second consisted of the cervicothoracic region and upper thighs; and the third consisted of the abdominopelvic area. Fetal doses from radiologic procedures between zones were compared using the Kruskal-Wallis test and a Bonferroni-corrected Mann-Whitney U-test. Results The average fetal doses from radiography and CT in the first zone were 0.05 ± 0.01 mGy and 0.81 ± 0.04 mGy, respectively; 0.21 ± 0.05 mGy and 1.77 ± 0.22 mGy, respectively, in the second zone; and 6.42 ± 0.82 mGy and 22.94 ± 1.28 mGy, respectively, in the third zone (p < 0.001). Our results showed that fetal radiation exposures in our group of pregnant women did not reach the level (50 mGy) that is known to increase risk for congenital anomalies. Conclusion Fetal radiation exposure in the diagnostic radiology procedures in our study did not reach risk levels that might have indicated abortion. PMID:26576117

  16. A Comparative Analysis of British and Taiwanese Students' Conceptual and Procedural Knowledge of Fraction Addition

    ERIC Educational Resources Information Center

    Li, Hui-Chuan

    2014-01-01

    This study examines students' procedural and conceptual achievement in fraction addition in England and Taiwan. A total of 1209 participants (561 British students and 648 Taiwanese students) at ages 12 and 13 were recruited from England and Taiwan to take part in the study. A quantitative design by means of a self-designed written test is adopted…

  17. 24 CFR 570.711 - State borrowers; additional requirements and application procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... requirements and application procedures. 570.711 Section 570.711 Housing and Urban Development Regulations... following: (1) A copy of the State's CDBG method of distribution in the action plan most recently submitted or amended pursuant to 24 CFR part 91. In addition to the requirements of 24 CFR part 91, such...

  18. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 1 2012-01-01 2012-01-01 false Additional requirements; Federal policies and procedures. 291.6 Section 291.6 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE...

  19. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 1 2014-01-01 2014-01-01 false Additional requirements; Federal policies and procedures. 291.6 Section 291.6 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE...

  20. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 1 2011-01-01 2011-01-01 false Additional requirements; Federal policies and procedures. 291.6 Section 291.6 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE...

  1. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 1 2013-01-01 2013-01-01 false Additional requirements; Federal policies and procedures. 291.6 Section 291.6 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE...

  2. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Additional requirements; Federal policies and procedures. 291.6 Section 291.6 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE...

  3. Development of procedures to ensure quality and integrity in Tandem Mirror Experiment-Upgrade (TMX-U) diagnostics systems

    SciTech Connect

    Coutts, G.W.; Coon, M.L.; Hinz, A.F.; Hornady, R.S.; Lang, D.D.; Lund, N.P.

    1983-11-30

    The diagnostic systems for Tandem Mirror Experiment-Upgrade (TMX-U) have grown from eleven initial systems to more than twenty systems. During operation, diagnostic system modifications are sometimes required to complete experimental objectives. Also, during operations new diagnostic systems are being developed and implemented. To ensure and maintain the quality and integrity of the data signals, a set of plans and systematic actions are being developed. This paper reviews the procedures set in place to maintain the integrity of existing data systems and ensure the performance objectives of new diagnostics being added.

  4. Reliability and Validity of a Procedure to Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    1990-01-01

    The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…

  5. Highly Reliable Procedural Teams: The Journey to Spread the Universal Protocol in Diagnostic Imaging

    PubMed Central

    Ross, Julie; Wolf, Debby; Reece, Kimberly

    2014-01-01

    Context: The Joint Commission’s Universal Protocol has been widely implemented in surgical settings since publication in 2003. The elements improved patient safety in operating rooms, and the same rigor is being applied to procedures occurring in other health care arenas, in particular, diagnostic imaging. Objective: In 2011, Kaiser Permanente West Los Angeles’s Diagnostic Imaging Department desired to adapt previous work on Universal Protocol implementation to improve patient safety in interventional radiology and mammography procedures. Design: The teams underwent human factors training and then adapted key interventions used in surgical suites to their workflows. Time-out posters, use of whiteboards, “glitch books,” and regular audits provided structure to overcome the risks that human factors present. Main Outcome Measures: Staff and physician perceptions of the teamwork and safety climates in their modalities were measured using the Safety Attitudes Questionnaire at baseline and at 18 months after training. Unusual Occurrence Reports were also reviewed to identify events and near misses that could be prevented. Implementation of key process changes were identified as process measures. Results: Perception of the safety climate improved 25% in interventional radiology and 4.5% in mammography. Perception of the teamwork climate decreased 5.4% in interventional radiology and 16.6% in mammography. Unusual occurrences were underreported at baseline, and there is ongoing reluctance to document near misses. Conclusion: This work provides important considerations of the impact of departmental cultures for the implementation of the Universal Protocol in procedural areas. It also reveals unexpected challenges, and requires long-term effort and focus. PMID:24626070

  6. Serum concentrations of prostate-specific antigen after diagnostic procedures and transurethral microwave thermotherapy of benign prostatic hyperplasia.

    PubMed

    Daehlin, L; Frugård, J; Farstad, M

    1996-05-01

    The objective was to study the effects of diagnostic and therapeutic procedures on serum prostate-specific antigen (PSA) concentration. Urethrocystoscopy in combination with digital rectal examination was followed by a moderate increase of serum PSA for 7-10 days. At 1 day after transurethral microwave thermotherapy (TUMT), an acute and pronounced effect on PSA was observed, which returned to baseline level after 4 weeks. The initial rise in serum PSA corresponded to a PSA density of 1.11, compared to 0.07 at baseline. The present data should be taken into consideration in conjunction with endoscopic evaluation of the lower urinary tract. Additionally, the acute effect on PSA after TUMT strongly suggests the ability of thermotherapy to induce cellular injury and death. One-year follow-up, however, was associated with increased PSA levels, indicating that only a minor part of the PSA-producing compartment was lost in the acute phase.

  7. Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India.

    PubMed

    Saravanakumar, A; Vaideki, K; Govindarajan, K N; Jayakumar, S

    2014-01-01

    Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level.

  8. Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India

    PubMed Central

    Saravanakumar, A.; Vaideki, K.; Govindarajan, K. N.; Jayakumar, S.

    2014-01-01

    Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level. PMID:24600173

  9. Non-inferiority test and confidence interval for the difference in correlated proportions in diagnostic procedures based on multiple raters.

    PubMed

    Saeki, Hiroyuki; Tango, Toshiro

    2011-12-10

    The efficacy of diagnostic procedures is generally evaluated on the basis of the results from multiple raters. However, there are few adequate methods of performing non-inferiority tests with confidence intervals to compare the accuracies (sensitivities or specificities) when multiple raters are considered. We propose new statistical methods for comparing the accuracies of two diagnostic procedures in a non-inferiority trial, on the basis of the results from multiple independent raters who are also independent of the study centers. We consider a study design in which each patient is subjected to two diagnostic procedures and all images are read by all raters. By assuming a multinomial distribution for matched-pair categorical data arising from the study design, we derive a score-based full menu, that is, a non-inferiority test, confidence interval and sample size formula, for inference of the difference in correlated proportions between the two diagnostic procedures. We conduct Monte Carlo simulation studies to examine the validity of the proposed methods, which showed that the proposed test has a size closer to the nominal significance level than a Wald-type test and that the proposed confidence interval has better empirical coverage probability than a Wald-type confidence interval. We illustrate the proposed methods with data from a study of diagnostic procedures for the diagnosis of oesophageal carcinoma infiltrating the tracheobronchial tree.

  10. Radiation Dose to the Skin and to the Gonads from Diagnostic X-Ray Procedures

    PubMed Central

    Duggan, H. E.; Olde, G. L.

    1963-01-01

    The design of a study to assess the hazard to patients from radiation received during diagnostic radiological procedures is described. The long-term accumulation of data relating to the skin and gonadal doses received by patients in a large x-ray department has been initiated. This will serve as a model for any situation involving small recurrent radiation doses to a significant proportion of the population. A description is given of the basic dose measurements made and the method used in calculating and recording the skin and gonadal doses for each patient. Although no definite conclusions concerning the presence or absence of a radiation hazard have yet been made, the proposed future course of this study is discussed. ImagesFig. 3Fig. 4 PMID:14079142

  11. Use of diagnostic imaging procedures and fetal monitoring devices in the care of pregnant women.

    PubMed Central

    Moore, R M; Jeng, L L; Kaczmarek, R G; Placek, P J

    1990-01-01

    Medical devices and diagnostic imaging procedures such as ultrasound, X-rays, and electronic fetal monitoring devices are used in the medical care of many pregnant women today. The responsibility for the safety and effectiveness of these diagnostic technologies is shared by a number of Public Health Service agencies, one of which is the Center for Devices and Radiological Health (CDRH), a unit within the Food and Drug Administration. The CDRH collaborated with the National Center for Health Statistics (NCHS) in conducting a study of recent trends in the uses of diagnostic ultrasound, medical X-rays, and electronic fetal monitoring devices in the medical care of pregnant women. This study used data from the 1980 National Natality and Fetal Mortality Surveys and the 1987 pretest to the National Maternal and Infant Health Survey. Hospitals and prenatal care providers of the pregnant women contributed information regarding the use of these medical devices. Between 1980 and 1987, ultrasound use more than doubled, increasing from 33.5 percent of pregnancies in 1980 to 78.8 percent in 1987 (P less than 0.001). More ultrasound examinations were performed earlier in gestation in 1987 than in 1980, with 10.1 percent being performed during the first trimester in 1987, compared with 6.9 percent in 1980 (P less than 0.001). Use of external electronic fetal monitoring devices during delivery also increased significantly between 1980 and 1987, from 33.5 percent to 74.6 percent (P less than 0.001). Use of medical X-rays among women with live births remained relatively unchanged, 15.0 percent in 1980 and 15.3 percent in 1987 (P = .282). The implications of these trends are discussed. PMID:2120723

  12. The German Competence Net Dementias: standard operating procedures for the neurochemical dementia diagnostics.

    PubMed

    Lewczuk, P; Kornhuber, J; Wiltfang, J

    2006-08-01

    Aging of population results in an increasing number of patients with dementia. Therefore, recently a BMBF-supported project, Competence Net Dementia, was launched to reveal diagnostic, therapeutic, and epidemiologic aspects of demential disorders. In this project, our task was to establish and maintain human body fluids (HBF) bank to collect cerebrospinal fluid, plasma, serum, and full blood of patients enrolled into the study. As the pre-analytical sample handling is a prerequisite of all studies aiming at finding novel disease biomarkers, standard operating procedures (SOPs) were launched by our group to allow standardized collection, storage, and shipment of the samples among all 14 University centers involved in HBF collection. Currently, to our best knowledge the CND HBF bank represents one of the largest prospectively collected set of the samples from subjects with mild cognitive impairment and early dementias. With the samples collected in the HBF bank, recently introduced analytical technologies (like e.g. surface enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS), differential gel electrophoresis (DIGE), and multiplexing) can be promptly tested with regard to their potential usefulness in neurochemical dementia diagnostics.

  13. Lost in Translation? Ethical Challenges of Implementing a New Diagnostic Procedure.

    PubMed

    Schmitz, Dagmar

    2016-01-01

    Since cell-free DNA (cfDNA) fragments of placental origin can be isolated and analyzed from the blood of pregnant women. Applications of this finding have been developed and implemented in clinical care pathways worldwide at an unprecedented pace and manner. Implementation patterns, however, exhibit considerable insufficiencies. Different "motors" of implementation processes, like the market or various regulatory institutions, can be identified at a national level. Each "motor" entails characteristic ethical challenges which are exemplified impressively by a rising number of case reports.Empirical data demonstrate that there are significant "losses" in the respective translational processes, especially when the results from clinical research are to be translated into the clinical reality of NIPT (the so called "second roadblock" (T2)). These "losses" are perceived in the fields of knowledge transfer, professional standardization and ethical debate. Recommendations of professional organizations often fail to reach general practitioners. Blindsided by the new diagnostic procedure in their clinical practice, professionals in prenatal care express their insecurities with regard to its handling. Ethical debate appears to adhere to pre-existing (and partly already proven to be insufficient) normative frameworks for prenatal testing. While all of these deficits are typical for the implementation processes of many new molecular diagnostic procedures, especially in NIPT, they show a high variability between different nations.A critical assessment of the preferred strategy of implementation against the background of already existing national ethical frameworks is indispensable, if potential adverse effects are to be diminished. The described translational losses seem to be significantly reducible by granting the translational process in roadblock T2 more time.

  14. Diagnostic procedures for non-small-cell lung cancer (NSCLC): recommendations of the European Expert Group

    PubMed Central

    Dietel, Manfred; Bubendorf, Lukas; Dingemans, Anne-Marie C; Dooms, Christophe; Elmberger, Göran; García, Rosa Calero; Kerr, Keith M; Lim, Eric; López-Ríos, Fernando; Thunnissen, Erik; Van Schil, Paul E; von Laffert, Maximilian

    2016-01-01

    Background There is currently no Europe-wide consensus on the appropriate preanalytical measures and workflow to optimise procedures for tissue-based molecular testing of non-small-cell lung cancer (NSCLC). To address this, a group of lung cancer experts (see list of authors) convened to discuss and propose standard operating procedures (SOPs) for NSCLC. Methods Based on earlier meetings and scientific expertise on lung cancer, a multidisciplinary group meeting was aligned. The aim was to include all relevant aspects concerning NSCLC diagnosis. After careful consideration, the following topics were selected and each was reviewed by the experts: surgical resection and sampling; biopsy procedures for analysis; preanalytical and other variables affecting quality of tissue; tissue conservation; testing procedures for epidermal growth factor receptor, anaplastic lymphoma kinase and ROS proto-oncogene 1, receptor tyrosine kinase (ROS1) in lung tissue and cytological specimens; as well as standardised reporting and quality control (QC). Finally, an optimal workflow was described. Results Suggested optimal procedures and workflows are discussed in detail. The broad consensus was that the complex workflow presented can only be executed effectively by an interdisciplinary approach using a well-trained team. Conclusions To optimise diagnosis and treatment of patients with NSCLC, it is essential to establish SOPs that are adaptable to the local situation. In addition, a continuous QC system and a local multidisciplinary tumour-type-oriented board are essential. PMID:26530085

  15. [Use of levofloxacin in the antibiotic prophylaxis for diagnostic procedures in urology].

    PubMed

    Trinchieri, Alberto; Mangiarotti, Barbara; Lizzano, Renata

    2002-03-01

    Chemoprophylaxis is the use of antimicrobial agents before contamination in the hope of preventing infections. The need for prophylaxis depends on the type of procedure and the risk for each individual patient. The risk for infection from urethral catheterization in a hospital setting is 5% for men and 10-20% for women, after routine cystoscopy is 4.7%, after transurethral resection of the bladder (TURB) is 39%, after transurethral resection of the prostate (TURP) is 6-43%, after transrectal biopsy of the prostate is 6.2-87%, and after shock wave lithotripsy is 5.7%. On this basis prophylactic treatment is recommended in all patients for transrectal prostate biopsy and transurethral surgery and in patients with increased risk of infection for diagnostic endoscopy of the urinary tract and SWL. Risk factors such as age, immunosuppression, metabolic dysfunction (e.g., diabetes), reduced general condition, prolonged operative time and bleeding, should be considered. Broad-spectrum cephalosporin, penicillins and fluoroquinolones are most often used. The choice of the drug also depends on its pharmacokinetic properties that should secure effective tissue levels during the procedure. Levofloxacin meets these criteria and reduces the incidence of infection after transrectal prostate biopsy and endoscopy of the urinary tract.

  16. Evaluation of additional lead shielding in protecting the physician from radiation during cardiac interventional procedures.

    PubMed

    Chida, Koichi; Morishima, Yoshiaki; Katahira, Yoshiaki; Chiba, Hiroo; Zuguchi, Masayuki

    2005-12-20

    Since cardiac interventional procedures deliver high doses of radiation to the physician, radiation protection for the physician in cardiac catheterization laboratories is very important. One of the most important means of protecting the physician from scatter radiation is to use additional lead shielding devices, such as tableside lead drapes and ceiling-mounted lead acrylic protection. During cardiac interventional procedures (cardiac IVR), however, it is not clear how much lead shielding reduces the physician dose. This study compared the physician dose [effective dose equivalent (EDE) and dose equivalent (DE)] with and without additional shielding during cardiac IVR. Fluoroscopy scatter radiation was measured using a human phantom, with an ionization chamber survey meter, with and without additional shielding. With the additional shielding, fluoroscopy scatter radiation measured with the human phantom was reduced by up to 98%, as compared with that without. The mean EDE (whole body, mean+/-SD) dose to the operator, determined using a Luxel badge, was 2.55+/-1.65 and 4.65+/-1.21 mSv/year with and without the additional shielding, respectively (p=0.086). Similarly, the mean DE (lens of the eye) to the operator was 15.0+/-9.3 and 25.73+/-5.28 mSv/year, respectively (p=0.092). In conclusion, although tableside drapes and lead acrylic shields suspended from the ceiling provided extra protection to the physician during cardiac IVR, the reduction in the estimated physician dose (EDE and DE) during cardiac catheterization with additional shielding was lower than we expected. Therefore, there is a need to develop more ergonomically useful protection devices for cardiac IVR.

  17. Toxicity Minimized Cryoprotectant Addition and Removal Procedures for Adherent Endothelial Cells

    PubMed Central

    Davidson, Allyson Fry; Glasscock, Cameron; McClanahan, Danielle R.; Benson, James D.; Higgins, Adam Z.

    2015-01-01

    Ice-free cryopreservation, known as vitrification, is an appealing approach for banking of adherent cells and tissues because it prevents dissociation and morphological damage that may result from ice crystal formation. However, current vitrification methods are often limited by the cytotoxicity of the concentrated cryoprotective agent (CPA) solutions that are required to suppress ice formation. Recently, we described a mathematical strategy for identifying minimally toxic CPA equilibration procedures based on the minimization of a toxicity cost function. Here we provide direct experimental support for the feasibility of these methods when applied to adherent endothelial cells. We first developed a concentration- and temperature-dependent toxicity cost function by exposing the cells to a range of glycerol concentrations at 21°C and 37°C, and fitting the resulting viability data to a first order cell death model. This cost function was then numerically minimized in our state constrained optimization routine to determine addition and removal procedures for 17 molal (mol/kg water) glycerol solutions. Using these predicted optimal procedures, we obtained 81% recovery after exposure to vitrification solutions, as well as successful vitrification with the relatively slow cooling and warming rates of 50°C/min and 130°C/min. In comparison, conventional multistep CPA equilibration procedures resulted in much lower cell yields of about 10%. Our results demonstrate the potential for rational design of minimally toxic vitrification procedures and pave the way for extension of our optimization approach to other adherent cell types as well as more complex systems such as tissues and organs. PMID:26605546

  18. Six additional cases of the KBG syndrome: clinical reports and outline of the diagnostic criteria.

    PubMed

    Zollino, M; Battaglia, A; D'Avanzo, M G; Della Bruna, M M; Marini, R; Scarano, G; Cappa, M; Neri, G

    1994-09-01

    A diagnosis of KBG syndrome was made in six unrelated patients. They presented with slight mental retardation, macrodontia, and skeletal abnormalities. Microcephaly, short stature, facial anomalies, and syndactylies were also noted. The diagnostic criteria of the KBG syndrome are discussed.

  19. Diagnostical mistakes in ablation procedures associated with a high placement of the leads V1-V3.

    PubMed

    Longo, Damián; Poliserpi, Claudio; Toscano Quilon, Francisco; Díaz Uberti, Pedro; López, Carlos; García-Niebla, Javier; Ramella, Irma

    2017-02-20

    The misplacement of electrodes for surface electrocardiogram (ECG) recording that we use daily as a reference for mapping precise locations in invasive procedures may, besides inducing diagnostical mistakes, greatly increase the duration of the procedure and making more feasible the incidence of complications, especially in ablation of arrhythmic substrates of ventricular outflow tracts such as premature ventricular contractions (PVC's) and accessory pathways, if the right precordial electrodes (V1-V3) are higher positioned.

  20. Can diagnostic and procedural skills required to practice cardiology as a specialist be mastered in 3 years?

    PubMed

    Yu, Eric H C; Nair, Parvathy; Sibbald, Matthew G; Lee, Douglas S; Dorian, Paul

    2015-01-01

    Cognitive and procedural skills required of cardiologists have increased in the past 10 years. What is unknown is whether residents consistently meet recommended volumes during training and what their own subjective assessments of their competency are after training. The purpose of this study was to (1) determine whether current training provides residents with opportunities to develop skills to function independently and (2) identify whether residents perceive gaps in their skills. We surveyed current and recent graduates of adult cardiology programs in Canada. One hundred ten responses from 425 surveys were received. Procedural and diagnostic test interpretation volumes were recorded, as were the optimum number the respondents believed were important to complete to function independently. These volumes were compared with the 2008 American College of Cardiology Core Cardiology Training Symposium (COCATS 3) and the Canadian Cardiovascular Society (CCS) recommendations for training. The proportion of residents meeting recommended volumes for diagnostic test interpretation ranged from 7% (Holter monitors) to 91% (echocardiograms). For procedures, the range was from 71% (echocardiography) to 100% (cardioversion). The ratio of residents' perceived minimum numbers believed to be required for proficiency for diagnostic test interpretation to those recommended ranged from 14% (electrocardiograms) to 116% (echocardiograms), and for procedures, the ratio was 66% (temporary pacemaker placement) to 116% (echocardiography). Recent graduates' perception of minimum required numbers to achieve competency is underestimated compared with COCATS 3 and CCS recommendations. Few graduates achieved the recommended volume targets suggested for diagnostic test interpretation.

  1. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Procedures for public consultation for payment for a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... establishing payment amounts for the list of codes made available to the public. (c) Not fewer than 30...

  2. A comparative analysis of British and Taiwanese students' conceptual and procedural knowledge of fraction addition

    NASA Astrophysics Data System (ADS)

    Li, Hui-Chuan

    2014-10-01

    This study examines students' procedural and conceptual achievement in fraction addition in England and Taiwan. A total of 1209 participants (561 British students and 648 Taiwanese students) at ages 12 and 13 were recruited from England and Taiwan to take part in the study. A quantitative design by means of a self-designed written test is adopted as central to the methodological considerations. The test has two major parts: the concept part and the skill part. The former is concerned with students' conceptual knowledge of fraction addition and the latter is interested in students' procedural competence when adding fractions. There were statistically significant differences both in concept and skill parts between the British and Taiwanese groups with the latter having a higher score. The analysis of the students' responses to the skill section indicates that the superiority of Taiwanese students' procedural achievements over those of their British peers is because most of the former are able to apply algorithms to adding fractions far more successfully than the latter. Earlier, Hart [1] reported that around 30% of the British students in their study used an erroneous strategy (adding tops and bottoms, for example, 2/3 + 1/7 = 3/10) while adding fractions. This study also finds that nearly the same percentage of the British group remained using this erroneous strategy to add fractions as Hart found in 1981. The study also provides evidence to show that students' understanding of fractions is confused and incomplete, even those who are successfully able to perform operations. More research is needed to be done to help students make sense of the operations and eventually attain computational competence with meaningful grounding in the domain of fractions.

  3. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    NASA Astrophysics Data System (ADS)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  4. Indiana Reading Diagnostic Assessment: Resource & Intervention Guide, Kindergarten. Additional Activities and Assessments

    ERIC Educational Resources Information Center

    Indiana Department of Education, 2006

    2006-01-01

    The materials included in this manual are organized according to the Indiana's Kindergarten Academic Standards for English/Language Arts. In each section teachers will find: (1) Indiana's Kindergarten Academic Standards for English/Language Arts Assessments: Black Line Masters of diagnostic/practice pages for skill areas, checklists, and rubrics;…

  5. Different procedures of diphenyleneiodonium chloride addition affect neutrophil extracellular trap formation.

    PubMed

    Ostafin, Magdalena; Pruchniak, Michal Przemyslaw; Ciepiela, Olga; Reznick, Abraham Zeev; Demkow, Urszula

    2016-09-15

    A unique strategy, in which invading microorganisms are being caught in web-like structures composed mainly of DNA, involves a recently described phenomenon called NETosis. This process seems to be related to the production of reactive oxygen species (ROS). In our study, the influence of diphenyleneiodonium chloride (DPI), which diminishes ROS production, was assessed in the context of neutrophil extracellular trap (NET) release. According to protocol, two distinguished procedures were compared, the first one involving DPI elimination from sample before cell activation and the second one proceeding without the step of inhibitor washout. The kinetics of DNA release was monitored by fluorometric assay, and NET formation was observed by fluorescent microscopy. The addition of DPI to the sample led to a reduction of extracellular DNA release. The strongest inhibition was noticed after treatment with 10 μM DPI, which was removed from medium before stimulation with phorbol-12-myristate-13-acetate (PMA). Our findings confirmed that DPI is able to block NET creation. However, the addition of DPI together with PMA or the addition of inhibitor initially and then washing it out before stimulation resulted in different levels of NET formation. Finally, DPI that remained in the system induced specific morphological changes in the neutrophils' nuclei that was not observed in the DPI washed out from sample.

  6. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  7. Influence of crushing and additive irradiation procedures on EPR dosimetry of tooth enamel

    SciTech Connect

    Shalom, S.V.; Chumak, V.V.; Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1996-01-01

    The effect of the crushing and additive dose procedures used in EPR dosimetry of enamel was studied on the signals with g-factors of 2. 0045 and g, = 2.0018, g. = 1.9975. Eight fractions, ranging in size from <75 micrometers to 2 mm, were prepared from one tooth. Two cases were investigated: crushing of a non-irradiated sample and of a sample previously irradiated (6 Gy from `Co gamma ray source). In the non-irradiated study, the intensity of the native signal at 2.0045 in by circa 1.75 times as the grain size decreased from maximum to minimum. A small in radiation sensitivity (< 8%) was also observed with decreasing grain size. In the irradiated samples, crushing resulted in slight variations of reconstructed doses from expected values, but the worst possible case (grain sizes < 75 micron) showed that additional errors were less than 10%. The radiation sensitivity of enamel measured immediately after exposure is underestimated. It increases by about 15% in the first month. Based on the decomposition of the observed spectra, a new interpretation of transient signals 1108 is proposed which explains the above phenomena. Recommendations about how to use this interpretation in retrospective EPR dosimetry are given.

  8. Impact of contacting study authors to obtain additional data for systematic reviews: diagnostic accuracy studies for hepatic fibrosis

    PubMed Central

    2014-01-01

    Background Seventeen of 172 included studies in a recent systematic review of blood tests for hepatic fibrosis or cirrhosis reported diagnostic accuracy results discordant from 2 × 2 tables, and 60 studies reported inadequate data to construct 2 × 2 tables. This study explores the yield of contacting authors of diagnostic accuracy studies and impact on the systematic review findings. Methods Sixty-six corresponding authors were sent letters requesting additional information or clarification of data from 77 studies. Data received from the authors were synthesized with data included in the previous review, and diagnostic accuracy sensitivities, specificities, and positive and likelihood ratios were recalculated. Results Of the 66 authors, 68% were successfully contacted and 42% provided additional data for 29 out of 77 studies (38%). All authors who provided data at all did so by the third emailed request (ten authors provided data after one request). Authors of more recent studies were more likely to be located and provide data compared to authors of older studies. The effects of requests for additional data on the conclusions regarding the utility of blood tests to identify patients with clinically significant fibrosis or cirrhosis were generally small for ten out of 12 tests. Additional data resulted in reclassification (using median likelihood ratio estimates) from less useful to moderately useful or vice versa for the remaining two blood tests and enabled the calculation of an estimate for a third blood test for which previously the data had been insufficient to do so. We did not identify a clear pattern for the directional impact of additional data on estimates of diagnostic accuracy. Conclusions We successfully contacted and received results from 42% of authors who provided data for 38% of included studies. Contacting authors of studies evaluating the diagnostic accuracy of serum biomarkers for hepatic fibrosis and cirrhosis in hepatitis C patients

  9. CT-guided percutaneous aspiration of Tarlov cyst as a useful diagnostic procedure prior to operative intervention.

    PubMed

    Lee, J-Y; Impekoven, P; Stenzel, W; Löhr, M; Ernestus, R-I; Klug, N

    2004-07-01

    Tarlov or perineural cysts are lesions of the nerve root most often found in the sacral region. Several authors recommend surgical treatment of symptomatic Tarlov cysts. However, successful surgical treatment is dependent on appropriate patient selection. In this article, we report three cases of a sacral perineural cyst, causing sciatic pain, and emphasize the usefulness of CT-guided percutaneous aspiration as an important diagnostic and prognostic procedure prior to definitive operative treatment.

  10. Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures

    NASA Astrophysics Data System (ADS)

    Liu, Haikuan; Gu, Jianwei; Caracappa, Peter F.; Xu, X. George

    2010-03-01

    The rapidly increasing number of diagnostic computed tomography (CT) procedures in the recent decades has spurred heightened concern over the potential risk to patients. Although an accurate organ dose assessment tool has now become highly desirable, existing software packages depend on stylized computational phantoms that were originally developed more than 40 years ago, exhibiting very large discrepancies when compared with phantoms that are anatomically realistic. However, past comparative studies did not focus on CT protocols for adult patients. This study was designed to quantitatively compare two types of phantoms, the stylized phantoms and a pair of recently developed RPI-adult male and adult female (RPI-AM and RPI-AF) phantoms, for various CT scanning protocols involving the chest, abdomen-pelvis and chest-abdomen-pelvis. Organ doses were based on Monte Carlo simulations using the MCNPX code and a detailed CT scanner model for the GE LightSpeed 16. Results are presented as ratios of organ doses from the stylized phantoms to those from the RPI phantoms. It is found that, for most organs contained in the scan volume, the ratios were within the range of 0.75-1.16. However, the stomach doses are significantly different and the ratio is found to be up to 1.86 in male phantoms and 2.29 in the female phantoms due to the anatomical differences between the two types of phantoms. Organs that lie near a scan boundary also exhibit a significant relative difference in organ doses between the two types of phantoms. This study concludes that, due to relatively low x-ray energies, CT doses are very sensitive to organ shape, size and position, and thus anatomically realistic phantoms should be used to avoid the dose uncertainties caused by the lack of anatomical realism. The new phantoms, such as the RPI-AM and AF phantoms that are designed using advanced surface meshes, are deformable and will make it possible to match the anatomy of a specific patient leading to further

  11. Incorrect Procedures Used by Primary Grade Pupils in Solving Open Addition and Subtraction Sentences.

    ERIC Educational Resources Information Center

    Lindvall, C. Mauritz; Ibarra, Cheryl Gibbons

    1980-01-01

    An exploratory investigation of various incorrect solution procedures used by students attempting to solve a variety of forms of open sentences is reported. The study identifies specific incorrect strategies, indicates their relative frequency of occurrence, and attempts to offer some explanation for certain of the incorrect procedures used. (MK)

  12. 75 FR 2122 - Additional Guidance Regarding Application of Current Procedures for Testing Energy Consumption of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-14

    ... ensure the consistent application of DOE's current test procedure to refrigerator-freezers with French doors, bottom-mounted freezers, and through-the-door (TTD) ice service (French door TTD models). This... application of the current test procedure to refrigerator- freezers with French doors, bottom-mounted...

  13. Italian Frontotemporal Dementia Network (FTD Group-SINDEM): sharing clinical and diagnostic procedures in Frontotemporal Dementia in Italy.

    PubMed

    Borroni, B; Turrone, R; Galimberti, D; Nacmias, B; Alberici, A; Benussi, A; Caffarra, P; Caltagirone, C; Cappa, S F; Frisoni, G B; Ghidoni, R; Marra, C; Padovani, A; Rainero, I; Scarpini, E; Silani, V; Sorbi, S; Tagliavini, F; Tremolizzo, L; Bruni, A C

    2015-05-01

    In the prospect of improved disease management and future clinical trials in Frontotemporal Dementia, it is desirable to share common diagnostic procedures. To this aim, the Italian FTD Network, under the aegis of the Italian Neurological Society for Dementia, has been established. Currently, 85 Italian Centers involved in dementia care are part of the network. Each Center completed a questionnaire on the local clinical procedures, focused on (1) clinical assessment, (2) use of neuroimaging and genetics; (3) support for patients and caregivers; (4) an opinion about the prevalence of FTD. The analyses of the results documented a comprehensive clinical and instrumental approach to FTD patients and their caregivers in Italy, with about 1,000 newly diagnosed cases per year and 2,500 patients currently followed by the participating Centers. In analogy to other European FTD consortia, future aims will be devoted to collect data on epidemiology of FTD and its subtypes and to provide harmonization of procedures among Centers.

  14. The London Procedure: A Screening Diagnostic and Teaching Guide for Adult Learning Problems.

    ERIC Educational Resources Information Center

    Travis, George Y.; And Others

    1978-01-01

    Describes development, composition, and interpretation of a series of individually administered tests to identify adult basic education learning problems. Test areas include screening for visual/auditory functions and diagnostic evaluation of visual/auditory perceptions and dyslexia. Results can provide basis for referral to medical or visual…

  15. Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures; Federal Guidance Report No. 14

    EPA Science Inventory

    Federal Guidance Report No. 14 provides federal facilities that use diagnostic and interventional x-ray equipment with updated recommendations for keeping doses as low as reasonably achievable without compromising the quality of patient care, This guidance is an update of Federal...

  16. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests.

    PubMed

    Shan, Guogen; Amei, Amei; Young, Daniel

    2015-01-01

    Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003). However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  17. Number Words in Young Children's Conceptual and Procedural Knowledge of Addition, Subtraction and Inversion

    ERIC Educational Resources Information Center

    Canobi, Katherine H.; Bethune, Narelle E.

    2008-01-01

    Three studies addressed children's arithmetic. First, 50 3- to 5-year-olds judged physical demonstrations of addition, subtraction and inversion, with and without number words. Second, 20 3- to 4-year-olds made equivalence judgments of additions and subtractions. Third, 60 4- to 6-year-olds solved addition, subtraction and inversion problems that…

  18. Theoretical modelling of experimental diagnostic procedures employed during pre-dose dosimetry of quartz.

    PubMed

    Pagonis, Vasilis; Chen, Reuven; Kitis, George

    2006-01-01

    The pre-dose technique in thermoluminescence (TL) is used for dating archaeological ceramics and for accident dosimetry. During routine applications of this technique, the sensitisation of the quartz samples is measured as a function of the annealing temperature, yielding the so-called thermal activation characteristic (TAC). The measurement of multiple TACs and the study of the effect of UV-radiation on the TL sensitivity of quartz are important analytical and diagnostic tools. In this paper, it is shown that a modified Zimmerman model for quartz can successfully model the experimental steps undertaken during a measurement of multiple TACs.

  19. Procedures to minimize diagnostic x-ray exposure of the human embryo and fetus. Final report

    SciTech Connect

    Not Available

    1980-08-01

    The recommendations published here are intended for the attending physician, the radiologist, the technologist, and the patient, delineating their respective roles in optimizing the x-ray exposure of pregnant or potentially pregnant women. These recommendations emphasize the necessity for attending physicians to determine whether or not their patients might be pregnant and to use this information in deciding on the need for an x-ray examination. The recommendations also stress the need to reduce x-ray exposure throughout gestation, and suggest ways in which this can be accomplished. X-ray exposure of the developing embryo and fetus has been a matter of concern for many years. Several national and international organizations have developed guidelines or policy statements on the subject. The BRH recommendations are expansions of the conceptual foundations provided by these other organizations, and they clarify the ways in which medical radiation exposure can be minimized without compromising the medical care of the mother. These recommendations are based on the principle that unnecessary or unproductive medical radiation exposure should be avoided or reduced to the extent possible, while preserving and improving the anticipated benefits of radiological diagnostic information. As with all medical applications of ionizing radiation, the physician's decision to obtain a diagnostic x-ray examination of a pregnant or potentially pregnant patient should be based on the judgment that the medical information obtained is likely to be important for appropriate patient management.

  20. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures

    PubMed Central

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P.

    2012-01-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging. PMID:22639482

  1. Towards A Discretely Actuated Steerable Cannula for Diagnostic and Therapeutic Procedures.

    PubMed

    Ayvali, Elif; Liang, Chia-Pin; Ho, Mingyen; Chen, Yu; Desai, Jaydev P

    2012-04-01

    We have designed, developed, and evaluated the performance of a multi-degree-of-freedom discretely actuated steerable cannula with shape memory alloy (SMA)actuators. This will enable us to deliver diagnostic as well as therapeutic devices to the target location through the hollow inner core of the cannula. We propose to use SMAs to generate bending forces due to its small size and high power density. We annealed the SMA wires through a customized training process in arc shape and mounted them at discrete locations on the outer surface of the cannula to enable joint motion. A pulse width modulation(PWM)-based control scheme was implemented to control all SMA actuators simultaneously to enable multiple joint motion using a single power supply. The proposed controller was validated through an experiment inside gelatin to mimic the motion of the cannula inside a medium which requires a significant amount of force to move the joints of the cannula. Trajectory planning using a suitable metric and trajectory execution were successfully implemented. To demonstrate the delivery of a diagnostic tool through our cannula, we demonstrate that we can pass an optical coherence tomography probe through the cannula and perform in situ micro-scale imaging.

  2. A World Allergy Organization International Survey on Diagnostic Procedures and Therapies in Drug Allergy/Hypersensitivity

    PubMed Central

    Mirakian, Rita; Castells, Mariana; Pichler, Werner; Romano, Antonino; Bonadonna, Patrizia; Diana, Deleanu; Kowalski, Marek; Yanez, Anahi; Lleonart, Ramon; Sanchez-Borges, Mario; Demoly, Pascal

    2011-01-01

    Objective To study the diagnostic and treatment modalities used in drug allergy/hypersensitivity among members of the World Allergy Organization (WAO). Methods A questionnaire comprising 39 questions was circulated electronically to member societies, associate member societies, and regional and affiliate organizations of WAO between June 29, 2009, and August 9, 2009. Results Eighty-two responses were received. Skin testing was used by 74.7%, with only 71.4% having access to penicillin skin test reagents. In vitro–specific IgE tests were used by 67.4%, and basophil activation test was used by 54.4%. Lymphocyte transformation tests were used by 36.8% and patch tests by 54.7%. Drug provocation tests were used by 68.4%, the most common indication being to exclude hypersensitivity where history/symptoms were not suggestive of drug hypersensitivity/allergy (76.9%). Rapid desensitization for chemotherapy, antibiotics, or biologic agents was used by 69.6%. Systemic corticosteroid was used in the treatment of Stevens–Johnson syndrome by 72.3%, and high-dose intravenous immunoglobulins in toxic epidermal necrolysis by 50.8%. Human leukocyte antigen screening before prescription of abacavir was used by 92.9% and before prescription of carbamazepine by 21.4%. Conclusions Results of this survey form a useful framework for developing educational and training needs and for improving access to drug allergy diagnostic and treatment modalities across WAO member societies. PMID:23268453

  3. Work-related stress and bullying: gender differences and forensic medicine issues in the diagnostic procedure

    PubMed Central

    2011-01-01

    Background The attention of international agencies and scientific community on bullying and work-related stress is increasing. This study describes the gender differences found in victims of bullying and work-related stress in an Italian case series and analyzes the critical issues in the diagnostic workup. Methods Between 2001 and 2009 we examined 345 outpatients (148 males, 197 females; mean age: 41 ± 10.49) for suspected psychopathological work-related problems. Diagnosis of bullying was established using international criteria (ICD-10 and DSM-IV). Results After interdisciplinary diagnostic evaluation (Occupational Medicine Unit, Psychology and Psychiatry Service), the diagnosis of bullying was formulated in 35 subjects, 12 males and 23 females (2 cases of Post-Traumatic Stress Disorder and 33 of Adjustment Disorder). Fifty-four (20 males, 34 females) suffered from work-related anxiety, while work-unrelated Adjustment Disorder and other psychiatric disorders were diagnosed in 7 and 112 subjects, respectively. Women between 34 and 45 years showed a high prevalence (65%) of "mobbing syndrome" or other work-related stress disorders. Conclusions At work, women are more subject to harassment (for personal aspects related to emotional and relational factors) than men. The knowledge of the phenomenon is an essential requisite to contrast bullying; prevention can be carried out only through effective information and training of workers and employers, who have the legal obligation to preserve the integrity of the mental and physical status of their employees during work. PMID:22088163

  4. [Quantitative measures for assessing the functional state of the human body during diagnostic procedure].

    PubMed

    Artemenko, M V

    2008-01-01

    Two approaches to calculation of the qualitative measures for assessing the functional state level of human body are considered. These approaches are based on image and fuzzy set recognition theories and are used to construct diagnostic decision rules. The first approach uses the data on deviation of detected parameters from those for healthy persons; the second approach analyzes the degree of deviation of detected parameters from the approximants characterizing the correlation differences between the parameters. A method for synthesis of decision rules and the results of blood count-based research for a number of diseases (hemophilia, thrombocytopathy, hypertension, arrhythmia, hepatic cirrhosis, trichophytia) are considered. An effect of a change in the functional link between the cholesterol content in blood and the relative rate of variation of AST and ALT enzymes in blood from direct proportional (healthy state) to inverse proportional (hepatic cirrhosis) is discussed. It is shown that analysis of correlation changes in detected parameters of the human body state during diagnostic process is more effective for application in decision support systems than the state space analysis.

  5. An Analysis of Incorrect Procedures Used by Primary Grade Pupils in Solving Open Addition and Subtraction Sentences.

    ERIC Educational Resources Information Center

    Lindvall, C. Mauritz; Ibarra, Cheryl Gibbons

    This study involved the extensive testing and interviewing of 102 primary grade pupils, representing a sampling from diverse school environments, to study the capabilities and difficulties evidenced by primary-grade pupils in solving open addition and subtraction sentences. Phase 1 of the study identified the specific incorrect procedures commonly…

  6. 21 CFR 330.14 - Additional criteria and procedures for classifying OTC drugs as generally recognized as safe and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Additional criteria and procedures for classifying OTC drugs as generally recognized as safe and effective and not misbranded. 330.14 Section 330.14 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS...

  7. Evaluating Generalization of Addition-Fact Fluency Using the Taped-Problems Procedure in a Second-Grade Classroom

    ERIC Educational Resources Information Center

    Miller, Kelli C.; Skinner, Christopher H.; Gibby, Lana; Galyon, Charles E.; Meadows-Allen, Sadonya

    2011-01-01

    A multiple-baseline design across math-fact sets was used to evaluate the effects of a taped-problems intervention on students' performance with addition facts and their inverses in an intact, rural, second-grade classroom. Results suggested that the procedure was effective in improving fluency on math facts as well as their inverses. Across 3…

  8. 13 CFR 108.1940 - Procedures for designation of additional Low-Income Geographic Areas

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) as LI Areas. (b) Criteria. SBA will consider one or more of the following factors in determining whether to designate a particular census tract (or equivalent county division) as an additional LI Area... designation of an additional LI Area, SBA will publish in the Federal Register a notice that it is...

  9. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) The test system shall send a Mode $01, PID $01 request in accordance with SAE J1979 to determine the... in accordance with SAE J1979. The procedure shall be done in accordance with SAE J1979 “E/E... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of SAE J1979 may be obtained from...

  10. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) The test system shall send a Mode $01, PID $01 request in accordance with SAE J1979 to determine the... in accordance with SAE J1979. The procedure shall be done in accordance with SAE J1979 “E/E... Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of SAE J1979 may be obtained from...

  11. Diagnostic procedures in tularaemia with special focus on molecular and immunological techniques.

    PubMed

    Splettstoesser, W D; Tomaso, H; Al Dahouk, S; Neubauer, H; Schuff-Werner, P

    2005-08-01

    Tularaemia is a severe bacterial zoonosis caused by the highly infectious agent Francisella tularensis. It is endemic in countries of the northern hemisphere ranging from North America to Europe, Asia and Japan. Very recently, Francisella-like strains causing disease in humans were described from tropical northern Australia. In the last decade, efforts have been made to develop sensitive and specific immunological and molecular techniques for the laboratory diagnosis of tularaemia and also for the definite identification of members of the species F. tularensis and its four subspecies. Screening for the keyword 'Francisella' a Medline search over the last decade was performed and articles describing diagnostic methods for tularaemia and its causative agent were selected. Besides classical microbiological techniques (cultivation, biochemical profiling, susceptibility testing) several new immunological and molecular approaches to identify F. tularensis have been introduced employing highly specific antibodies and various polymerase chain reaction (PCR)-based methods. Whereas direct antigen detection by enzyme-linked immunosorbent assay (ELISA) or immunofluorescence might allow early presumptive diagnosis of tularaemia, these methods--like all PCR techniques--still await further evaluation. Therefore, diagnosis of tularaemia still relies mainly on the demonstration of specific antibodies in the host. ELISA and immunoblot methods started to replace the standard tube or micro-agglutination assays. However, the diagnostic value of antibody detection in the very early clinical phase of tularaemia is limited. Francisella tularensis is regarded as a 'highest priority' biological agent (category 'A' according to the CDC, Atlanta, GA, USA), thus rapid and reliable diagnosis of tularaemia is required not only for a timely onset of therapy, the handling of outbreak investigations but also for the surveillance of endemic foci. Only very recently, evaluated test kits for

  12. Rapid sandwich ELISA-based in vitro diagnostic procedure for the highly-sensitive detection of human fetuin A.

    PubMed

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2015-05-15

    A rapid sandwich enzyme-linked immunosorbent assay (ELISA)-based in vitro diagnostic (IVD) procedure has been developed for human fetuin A (HFA), an important disease biomarker for inflammatory diseases as well as malignancies. In this simplified and cost-effective procedure, the EDC-activated anti-HFA antibody (Ab) was admixed with 1% (v/v) 3-aminopropyltriethoxysilane (APTES) in 1:1 (v/v) and dispensed in a KOH-pretreated microtiter plate (MTP). APTES formed a stable complex with the capture antibody that was in turn covalently bonded on the KOH-treated surface in 30 min. The resulting immunoassay (IA) format detects HFA with a dynamic range of 0.1-243 ng mL(-1), and a limit of detection (LOD) and analytical sensitivity of 0.3 ng mL(-1) and 1.0 ng mL(-1), respectively. For the determination of HFA spiked in diluted human whole blood and serum, and HFA in ethylenediaminetetraacetic acid (EDTA)-plasma of patients, the obtained analytical precision is similar to that of the conventional sandwich ELISA. The anti-HFA Ab-bound MTPs, stored at 4 °C in 0.1M PBS, pH 7.4, retained its biological activity for 8 weeks, thereby demonstrating excellent storage stability. This generic sandwich ELISA procedure can be extended for rapid, simplified and cost-effective detection of other disease biomarkers.

  13. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures.

    PubMed

    Brahme, Anders; Nyman, Peter; Skatt, Björn

    2008-05-01

    A four-dimensional (4D) laser camera (LC) has been developed for accurate patient imaging in diagnostic and therapeutic radiology. A complementary metal-oxide semiconductor camera images the intersection of a scanned fan shaped laser beam with the surface of the patient and allows real time recording of movements in a three-dimensional (3D) or four-dimensional (4D) format (3D +time). The LC system was first designed as an accurate patient setup tool during diagnostic and therapeutic applications but was found to be of much wider applicability as a general 4D photon "tag" for the surface of the patient in different clinical procedures. It is presently used as a 3D or 4D optical benchmark or tag for accurate delineation of the patient surface as demonstrated for patient auto setup, breathing and heart motion detection. Furthermore, its future potential applications in gating, adaptive therapy, 3D or 4D image fusion between most imaging modalities and image processing are discussed. It is shown that the LC system has a geometrical resolution of about 0, 1 mm and that the rigid body repositioning accuracy is about 0, 5 mm below 20 mm displacements, 1 mm below 40 mm and better than 2 mm at 70 mm. This indicates a slight need for repeated repositioning when the initial error is larger than about 50 mm. The positioning accuracy with standard patient setup procedures for prostate cancer at Karolinska was found to be about 5-6 mm when independently measured using the LC system. The system was found valuable for positron emission tomography-computed tomography (PET-CT) in vivo tumor and dose delivery imaging where it potentially may allow effective correction for breathing artifacts in 4D PET-CT and image fusion with lymph node atlases for accurate target volume definition in oncology. With a LC system in all imaging and radiation therapy rooms, auto setup during repeated diagnostic and therapeutic procedures may save around 5 min per session, increase accuracy and allow

  14. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship With Respect to Cervical and Cranial Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle

    2012-01-01

    Objective: The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Methods: Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009–2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. Results: In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and “muscle” adjustments. Conclusion: There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction PMID:22778531

  15. 77 FR 26314 - National Environmental Policy Act: Implementing Procedures; Addition to Categorical Exclusions...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ... single- family homesites on Indian land, including associated improvements and easements, which encompass... with single-family homes by preparing EAs; the addition of a categorical exclusion to cover these... leases or funds for single-family homesites, including associated improvements and easements on...

  16. Smart on-board diagnostic decision trees for quantitative aviation equipment and safety procedures validation

    NASA Astrophysics Data System (ADS)

    Ali, Ali H.; Markarian, Garik; Tarter, Alex; Kölle, Rainer

    2010-04-01

    The current trend in high-accuracy aircraft navigation systems is towards using data from one or more inertial navigation subsystem and one or more navigational reference subsystems. The enhancement in fault diagnosis and detection is achieved via computing the minimum mean square estimate of the aircraft states using, for instance, Kalman filter method. However, this enhancement might degrade if the cause of a subsystem fault has some effect on other subsystems that are calculating the same measurement. One instance of such case is the tragic incident of Air France Flight 447 in June, 2009 where message transmissions in the last moment before the crash indicated inconsistencies in measured airspeed as reported by Airbus. In this research, we propose the use of mathematical aircraft model to work out the current states of the airplane and in turn, using these states to validate the readings of the navigation equipment throughout smart diagnostic decision tree network. Various simulated equipment failures have been introduced in a controlled environment to proof the concept of operation. The results have showed successful detection of the failing equipment in all cases.

  17. [The syndrome of increased upper airways resistance: What are the clinical features and diagnostic procedures?].

    PubMed

    M'saad, S; Yangui, I; Feki, W; Abid, N; Bahloul, N; Marouen, F; Chakroun, A; Kammoun, S

    2015-12-01

    The upper airway resistance syndrome "UARS" is a poorly defined entity, often described as a moderate variant of the obstructive sleep apnea syndrome. It is associated with respiratory effort-related arousal, absence of obstructive sleep apnea, and absence of significant desaturation. It is a relatively common condition that predominantly affects non-obese young adults, with no predominance in either sex. The degree of upper airway collapsibility during sleep of patients with UARS is intermediate between that of normal subjects and that of patients with mild-to-moderate sleep apnea syndrome. Craniofacial and palatal abnormalities are often noted. Patients frequently complain of a functional somatic syndrome, especially daytime sleepiness and chronic fatigue. Polysomnography with esophageal pressure measurements remains the gold standard diagnostic test. The absence of any neurological abnormality gives UARS a good prognosis and it is potentially reversible if treated early. However, some studies suggest that untreated UARS has an increased risk of arterial hypertension. It can also evolve into obstructive sleep apnea.

  18. To amend the National Security Act of 1947 to provide additional procedures for congressional oversight.

    THOMAS, 111th Congress

    Rep. Thornberry, Mac [R-TX-13

    2009-12-10

    12/10/2009 Referred to the Committee on Intelligence (Permanent Select), and in addition to the Committee on Rules, for a period to be subsequently determined by the Speaker, in each case for consideration of such provisions as fall within the jurisdiction of the committee concerned. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  19. Fructose breath hydrogen test--is it really a harmless diagnostic procedure?

    PubMed

    Müller, P; Meier, C; Böhme, H J; Richter, T

    2003-01-01

    Usage of hydrogen breath tests has become one of the standard procedures in diagnosing chronic unspecific abdominal pain. These tests are said to be of sufficient specificity and sensitivity, are easily done, non-invasive and are more often practiced in outpatients. A 13-year-old boy is reported with chronic unspecific abdominal pain and growth retardation and so far misdiagnosed hereditary fructose intolerance (HFI), who developed life-threatening adverse effects during the fructose breath hydrogen test. It is concluded that the possibility of HFI should be excluded first by a carefully explored dietary history before the fructose breath test is performed under medical supervision. If there is any suspicion of HFI, a molecular genetic analysis should be preferred.

  20. Application of Routine Diagnostic Procedure, VITEK 2 Compact, MALDI-TOF MS, and PCR Assays in Identification Procedure of Bacterial Strain with Ambiguous Phenotype.

    PubMed

    Książczyk, Marta; Kuczkowski, Maciej; Dudek, Bartłomiej; Korzekwa, Kamila; Tobiasz, Anna; Korzeniowska-Kowal, Agnieszka; Paluch, Emil; Wieliczko, Alina; Bugla-Płoskońska, Gabriela

    2016-05-01

    In diagnostic microbiology as well as in microbiological research, the identification of a microorganism is a crucial and decisive stage. A broad choice of methods is available, based on both phenotypic and molecular properties of microbes. The aim of this study was to compare the application of phenotypic and molecular tools in bacterial identification on the example of Gram-negative intestine rod with an ambiguous phenotype. Different methods of identification procedure, which based on various properties of bacteria, were applied, e.g., microscopic observation of single-bacterial cells, macroscopic observation of bacterial colonies morphology, the automated system of microorganism identification (biochemical tests), the mass spectrometry method (analysis of bacterial proteome), and genetic analysis with PCR reactions. The obtained results revealed discrepancies in the identification of the tested bacterial strain with an atypical phenotype: mucous morphology of colonies, not characteristic for either E. coli and Citrobacter spp., mass spectrometry analysis of proteome initially assigned the tested strain to Citrobacter genus (C. freundii) and biochemical profiles pointed to Escherichia coli. A decisive method in the current study was genetic analysis with PCR reactions which identified conserved genetic sequences highly specific to E. coli species in the genome of the tested strain.

  1. Pulmonary infiltrates in non-HIV immunocompromised patients: a diagnostic approach using non-invasive and bronchoscopic procedures

    PubMed Central

    Rano, A; Agusti, C; Jimenez, P; Angrill, J; Benito, N; Danes, C; Gonzalez, J; Rovira, M; Pumarola, T; Moreno, A; Torres, A

    2001-01-01

    %); and TBAS 35/55 (65%). Bronchoscopic techniques led to the diagnosis of pulmonary infiltrates in 59% of the cases in which they were used: FBAS 16/28 (57%), BAL 68/135 (51%), and PSB 30/125 (24%). The results obtained with the different techniques led to a change in antibiotic treatment in 93 cases (46%). Although changes in treatment did not have an impact on the overall mortality, patients with pulmonary infiltrates of an infectious aetiology in whom the change was made during the first 7 days had a better outcome (29% mortality) than those in whom treatment was changed later (71% mortality; p=0.001).
CONCLUSIONS—Non-invasive and bronchoscopic procedures are useful techniques for the diagnosis of pulmonary infiltrates in immunocompromised patients. Bronchial aspirates (FBAS and TBAS) and BAL have the highest diagnostic yield and impact on therapeutic decisions.

 PMID:11312407

  2. Evolving American Society for Testing and Materials (ASTM) Procedures On Use Of Infrared (IR) Imaging Devices For Building Diagnostics

    NASA Astrophysics Data System (ADS)

    Wood, James T.

    1981-01-01

    In the summer of 1979 a task group was formed under ASTM Subcommittee C16.30 Section 7. The task group was asked to develop standard practices for the utilization of infrared (IR) imaging devices for the in-situ evaluation of building insulation systems. The group's work to date has concentrated on bounding the problem and prioritizing the needs for standard procedures. Most recently, the group has concentrated on a very specific utilization of infrared (IR) imaging as a qualitative instrument for building retrofit insulation inspections. White papers on equipment specifications and interpretation of imagery were generated as guides to writing the first draft of a standard practice document on this insulation retrofit inspection problem. The first draft describes the knowledge level of the inspector, the procedures for the inspection and the instrumentation required for various levels of diagnostics. Care has been taken to insure compatibility with ASHRAE Draft Standard 101P and to insure that the document will serve the user community as a guide to proper application of infrared in this infrared (IR) applications area.

  3. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software.

    PubMed

    Poulet, Axel; Privat, Maud; Ponelle, Flora; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S; Uhrhammer, Nancy; Bignon, Yves-Jean; Bidet, Yannick

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts.

  4. Improved Efficiency and Reliability of NGS Amplicon Sequencing Data Analysis for Genetic Diagnostic Procedures Using AGSA Software

    PubMed Central

    Poulet, Axel; Privat, Maud; Viala, Sandrine; Decousus, Stephanie; Perin, Axel; Lafarge, Laurence; Ollier, Marie; El Saghir, Nagi S.

    2016-01-01

    Screening for BRCA mutations in women with familial risk of breast or ovarian cancer is an ideal situation for high-throughput sequencing, providing large amounts of low cost data. However, 454, Roche, and Ion Torrent, Thermo Fisher, technologies produce homopolymer-associated indel errors, complicating their use in routine diagnostics. We developed software, named AGSA, which helps to detect false positive mutations in homopolymeric sequences. Seventy-two familial breast cancer cases were analysed in parallel by amplicon 454 pyrosequencing and Sanger dideoxy sequencing for genetic variations of the BRCA genes. All 565 variants detected by dideoxy sequencing were also detected by pyrosequencing. Furthermore, pyrosequencing detected 42 variants that were missed with Sanger technique. Six amplicons contained homopolymer tracts in the coding sequence that were systematically misread by the software supplied by Roche. Read data plotted as histograms by AGSA software aided the analysis considerably and allowed validation of the majority of homopolymers. As an optimisation, additional 250 patients were analysed using microfluidic amplification of regions of interest (Access Array Fluidigm) of the BRCA genes, followed by 454 sequencing and AGSA analysis. AGSA complements a complete line of high-throughput diagnostic sequence analysis, reducing time and costs while increasing reliability, notably for homopolymer tracts. PMID:27656653

  5. A Comparison of Six Different Diagnostic Procedures Used To Check Raw Quantitative Data for Outliers in a Generic Science Education Study.

    ERIC Educational Resources Information Center

    McGinnis, James Randy

    This generic science education study demonstrates the contrast of findings obtained through analyzing all the raw data as opposed to removing various combinations of identified potential outliers provided through the application of six diagnostic procedures. Outliers are defined as extreme data points with large residuals. It is argued that an…

  6. Should excretory urography be used as a routine diagnostic procedure in patients with acute ureteric colic: a single center study.

    PubMed

    Samara, Osama A; Haroun, Dina A; Ashour, Do'a Z; Tarawneh, Emad S; Haroun, Azmi A

    2011-05-01

    The aim of this study was to find an accurate, easily available and safe imaging modality as an alternative to intravenous urography for the diagnosis of acute urinary obstruction. This retrospective study included 332 patients, who underwent both excretory urography (EU) preceeded by plain radiograph as well as ultrasonography for evaluation of acute flank pain. There were 198 male and 134 female patients. The presence or absence of urinary stones, level of obstruction, excretion delay on EU and dilated excretory system on either or both techniques were recorded. The sensitivity, specificity, predictive values, and accuracy for plain radiograph, ultrasonography, and for both modalities together were measured considering EU as a standard reference. The sensitivity and specificity of combined plain radiograph and ultrasound were 97% and 67%, respectively, with positive and negative predictive values and accuracy rates of 92%, 99%, and 97%, respectively. Our study suggests that the combination of plain radiograph and ultrasonography yields a high sensitivity, negative predictive value, and accuracy in depiction of urinary stones. Thus, EU need not be used as a routine diagnostic procedure in patients with acute obstructive uropathy.

  7. Diagnostic Tests and Procedures

    MedlinePlus

    ... your heart with a stethoscope. This is called auscultation, which means the study of heart sounds. Doctors ... diagnose some types of heart valve disease by listening to any abnormal heart sounds that they hear ...

  8. SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

    SciTech Connect

    Mahmood, U; Erdi, Y

    2015-06-15

    Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

  9. Longitudinal Slit Procedure in Addition to Negative Pressure Wound Therapy for a Refractory Wound With Exposed Achilles Tendon

    PubMed Central

    Ohata, Erika; Mishima, Yoshito; Matsuo, Kiyoshi

    2015-01-01

    Objective: This case report reviews features of negative pressure wound therapy, particularly for the exposed Achilles tendon, and describes an additional effective procedure. Methods: An 87-year-old man presented with a soft-tissue defect measuring 3×5 cm with the exposed Achilles tendon as a sequela of deep burn. The condition of his affected leg was ischemic because of arteriosclerosis. We used negative pressure wound therapy and made 2 longitudinal slits penetrating the tendon to induce blood flow from the ventral side to the dorsal surface. Results: By this combination therapy, the surface of the exposed Achilles tendon was completely epithelialized and the tendon was spared without disuse syndrome. Conclusions: The authors conclude that this combination therapy is useful for covering the widely exposed tendon in aged patients. PMID:25848445

  10. Randomized pilot study and qualitative evaluation of a clinical decision support system for brain tumour diagnosis based on SV ¹H MRS: evaluation as an additional information procedure for novice radiologists.

    PubMed

    Sáez, Carlos; Martí-Bonmatí, Luis; Alberich-Bayarri, Angel; Robles, Montserrat; García-Gómez, Juan M

    2014-02-01

    The results of a randomized pilot study and qualitative evaluation of the clinical decision support system Curiam BT are reported. We evaluated the system's feasibility and potential value as a radiological information procedure complementary to magnetic resonance (MR) imaging to assist novice radiologists in diagnosing brain tumours using MR spectroscopy (1.5 and 3.0T). Fifty-five cases were analysed at three hospitals according to four non-exclusive diagnostic questions. Our results show that Curiam BT improved the diagnostic accuracy in all the four questions. Additionally, we discuss the findings of the users' feedback about the system, and the further work to optimize it for real environments and to conduct a large clinical trial.

  11. Nuclear medicine practices in the 1950s through the mid-1970s and occupational radiation doses to technologists from diagnostic radioisotope procedures.

    PubMed

    Drozdovitch, Vladimir; Brill, Aaron B; Mettler, Fred A; Beckner, William M; Goldsmith, Stanley J; Gross, Milton D; Hays, Marguerite T; Kirchner, Peter T; Langan, James K; Reba, Richard C; Smith, Gary T; Bouville, André; Linet, Martha S; Melo, Dunstana R; Lee, Choonsik; Simon, Steven L

    2014-10-01

    Data on occupational radiation exposure from nuclear medicine procedures for the time period of the 1950s through the 1970s is important for retrospective health risk studies of medical personnel who conducted those activities. However, limited information is available on occupational exposure received by physicians and technologists who performed nuclear medicine procedures during those years. To better understand and characterize historical radiation exposures to technologists, the authors collected information on nuclear medicine practices in the 1950s, 1960s, and 1970s. To collect historical data needed to reconstruct doses to technologists, a focus group interview was held with experts who began using radioisotopes in medicine in the 1950s and the 1960s. Typical protocols and descriptions of clinical practices of diagnostic radioisotope procedures were defined by the focus group and were used to estimate occupational doses received by personnel, per nuclear medicine procedure, conducted in the 1950s to 1960s using radiopharmaceuticals available at that time. The radionuclide activities in the organs of the reference patient were calculated using the biokinetic models described in ICRP Publication 53. Air kerma rates as a function of distance from a reference patient were calculated by Monte Carlo radiation transport calculations using a hybrid computational phantom. Estimates of occupational doses to nuclear medicine technologists per procedure were found to vary from less than 0.01 μSv (thyroid scan with 1.85 MBq of administered I-iodide) to 0.4 μSv (brain scan with 26 MBq of Hg-chlormerodin). Occupational doses for the same diagnostic procedures starting in the mid-1960s but using Tc were also estimated. The doses estimated in this study show that the introduction of Tc resulted in an increase in occupational doses per procedure.

  12. Prenatal Diagnosis Procedures and Techniques to Obtain a Diagnostic Fetal Specimen or Tissue: Maternal and Fetal Risks and Benefits.

    PubMed

    Wilson, R Douglas; Gagnon, Alain; Audibert, François; Campagnolo, Carla; Carroll, June

    2015-07-01

    Objectif : Offrir aux fournisseurs de soins de maternité et à leurs patientes des lignes directrices factuelles contemporaines en ce qui concerne les services de counseling traitant des risques et des avantages maternels propres à la tenue des interventions diagnostiques prénatales orientées par échographie (et/ou des techniques permettant l’établissement d’un diagnostic génétique) nécessaires dans les cas où il a été établi pendant la période prénatale que la grossesse serait exposée à des risques, ainsi qu’en ce qui concerne la prise de décisions subséquentes quant à la prise en charge de la grossesse (questions abordant des aspects tels que le niveau du fournisseur de soins obstétricaux, la surveillance prénatale, le lieu où devraient se dérouler les soins et l’accouchement, et la décision de poursuivre ou d’interrompre la grossesse). La présente directive clinique se limite aux services de counseling traitant des risques et des avantages maternels, et aux décisions en matière de prise en charge de la grossesse pour les femmes qui nécessitent (ou qui envisagent) la mise en œuvre d’une intervention ou d’une technique effractive orientée par échographie aux fins de l’établissement d’un diagnostic prénatal. Population de patientes : Femmes enceintes identifiées, à la suite de la mise en œuvre de protocoles établis de dépistage prénatal (taux sériques maternels ± imagerie, résultats d’analyse de l’ADN acellulaire indiquant des risques élevés, résultats anormaux au moment de l’imagerie fœtale diagnostique ou antécédents familiaux de troubles héréditaires), comme étant exposées à un risque accru d’anomalie génétique fœtale. Ces femmes pourraient nécessiter ou demander des services de counseling au sujet des risques et des avantages pour la grossesse de la tenue d’une intervention effractive orientée par échographie visant à déterminer l’étiologie, le diagnostic, et/ou la

  13. Degree of Vertical Integration Between the Undergraduate Program and Clinical Internship with Respect to Lumbopelvic Diagnostic and Therapeutic Procedures Taught at the Canadian Memorial Chiropractic College

    PubMed Central

    Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J.

    2010-01-01

    Purpose: The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. Methods: A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Results: Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. Conclusion: This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college. PMID:20480014

  14. [First guidelines of Croatian interest group in diagnosing and treating lower back and radicular pain using minimally invasive diagnostic and therapeutic procedures].

    PubMed

    Houra, Karlo; Perović, Darko; Kvesić, Drazen; Rados, Ivan; Kovac, Damir; Kapural, Leonardo

    2013-01-01

    Low back and radicular pain recently became a major public health problem. Medical expenses in general, and surgical procedures associated with overall care for the lower back pain are high and growing. Furthermore, these two chronic pain conditions are also leading causes for missed workdays. Degenerative changes of the intervertebral disc, facet joints, sacroiliac joint or disc herniation as described during imaging diagnostics may or may not be the cause of patients' lower back pain. Diagnostic blocks often precede further interventions in order to confirm or dispute a source of the lower back pain. Chronic lower back pain caused by painful intervertebral disc should be treated using biacuplasty. If the pain of the lumbar spine is caused by facet joints or sacroiliac joint, patient can be offered neuroablative procedures using radiofrequency. In cases where the low back and radicular pain are caused by the central and foraminal spinal stenosis patients are advised epidural steroid injections, unless claudications are present. Patients suffering from the chronic radicular pain may be treated with various nucleoplasty procedures or they may be offered percutaneous radiofrequent neuromodulation. The purpose of above advised procedures is to relieve patients' pain, allow optimal physical therapy, and improved functional capacity, consequently providing better quality of life.

  15. Assessment procedures for narcissistic personality disorder: a comparison of the personality diagnostic questionnaire-4 and best-estimate clinical judgments.

    PubMed

    Miller, Joshua D; Campbell, W Keith; Pilkonis, Paul A; Morse, Jennifer Q

    2008-12-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD) methodology. NPD scores demonstrated moderate convergence for the total scores but weak convergence for the individual criteria. The authors also examined the correlates created by each set of NPD scores using Cloninger's Temperament and Character Inventory (TCI). The NPD scores demonstrated areas of convergence (e.g., Cooperativeness, Self-directedness) and divergence (i.e., Harm Avoidance, Novelty Seeking) with these personality scores. These divergences may be due to the wording of certain items on the Personality Diagnostic Questionnaire-4 NPD scale, which may require rewriting if it is to provide an assessment that is more highly convergent with the Diagnostic and Statistical Manual of Mental Disorders NPD construct.

  16. Interrelation of Evaluation and Self-Evaluation in the Diagnostic Procedures to Assess Teachers' Readiness for Innovation

    ERIC Educational Resources Information Center

    Tyunnikov, Yurii S.

    2016-01-01

    The paper solves the problem of the relationship of external diagnosis and self-diagnosis of readiness of teachers to innovative activity. It highlights major disadvantages of measurement tools that are used to this process. The author demonstrates an alternative approach to harmonizing the diagnosis, based on a modular diagnostic model, general…

  17. Reliability and Validity of a Procedure To Measure Diagnostic Reasoning and Problem-Solving Skills Taught in Predoctoral Orthodontic Education.

    ERIC Educational Resources Information Center

    Albanese, Mark A.; Jacobs, Richard M.

    Preliminary psychometric data assessing the reliability and validity of a method used to measure the diagnostic reasoning and problem-solving skills of predoctoral students in orthodontia are described. The measurement approach consisted of sets of patient demographic data and dental photos and x-rays, accompanied by a set of 33 multiple-choice…

  18. Assessment Procedures for Narcissistic Personality Disorder: A Comparison of the Personality Diagnostic Questionnaire-4 and Best-Estimate Clinical Judgments

    ERIC Educational Resources Information Center

    Miller, Joshua D.; Campbell, W. Keith; Pilkonis, Paul A.; Morse, Jennifer Q.

    2008-01-01

    This study examined the degree of correspondence between two assessments for narcissistic personality disorder (NPD) in a mixed clinical and community sample--one using a self-report measure (Personality Diagnostic Questionnaire-4) and the other using clinical judgments derived from an assessment based on the longitudinal, expert, all data (LEAD)…

  19. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  20. Spinal palpatory diagnostic procedures utilized by practitioners of spinal manipulation: annotated bibliography of content validity and reliability studies

    PubMed Central

    Seffinger, Michael; Adams, Alan; Najm, Wadie; Dickerson, Vivian; Mishra, Shiraz I; Reinsch, Sibylle; Murphy, Linda

    2003-01-01

    The diagnosis of spinal neuro-musculoskeletal dysfunction is a pre-requisite for application of spinal manual therapy. Different disciplines rely on palpatory procedures to establish this diagnosis and design treatment plans. Over the past 30 years, the osteopathic, chiropractic, physical therapy and allopathic professions have investigated the validity and reliability of spinal palpatory procedures. We explored the literature from all four disciplines looking for scientific papers studying the content validity and reliability of spinal palpatory procedures. Thirteen databases were searched for relevant papers between January 1966 and October 2001. An annotated bibliography of these articles is presented and organized by the type of test used.

  1. Patients benefit from the addition of KIR repertoire data to the donor selection procedure for unrelated haematopoietic stem cell transplantation.

    PubMed

    Schellekens, Jennifer; Rozemuller, Erik H; Petersen, Eefke J; van den Tweel, Jan G; Verdonck, Leo F; Tilanus, Marcel G J

    2008-02-01

    Killer cell immunoglobulin-like receptors (KIRs) expressed on donor natural killer (NK) cells are important for induction of NK cell alloreactivity in haematopoietic stem cell transplantation (HSCT). Current criteria in the selection procedure of an unrelated donor do not account for this potential NK alloresponse. In this study the KIR gene repertoire of 21 HSCT patients and all their potential, unrelated donors (N=64) has been identified by the sequence-specific priming (SSP) procedure. KIR genotype characteristics are correlated with HLA and clinical data. These data show that for 16 cases an HLA compatible alternative donor was available. Among those 16 were 8 donors with a favourable predicted NK alloreactivity directed against the leukaemic cells. In conclusion, it is feasible and clinically relevant to add the KIR repertoire to the unrelated donor selection procedure.

  2. ‘Double Trouble’: Diagnostic Challenges in Duchenne Muscular Dystrophy in Patients with an Additional Hereditary Skeletal Dysplasia

    PubMed Central

    Donkervoort, Sandra; Schindler, Alice; Tesi-Rocha, Carolina; Schreiber, Allison; Leach, Meganne E.; Dastgir, Jahannaz; Hu, Ying; Mankodi, Ami; Wagner, Kathryn R.; Friedman, Neil R.; Bönnemann, Carsten G.

    2015-01-01

    Duchenne muscular dystrophy (DMD) is caused by mutations Dystrophin and affects 1 in 3600-6000 males. It is characterized by progressive weakness, leading to loss of ambulation, respiratory insufficiency, cardiomyopathy, and scoliosis. We describe the unusual phenotype of 3 patients with skeletal dysplasias in whom an additional diagnosis of DMD was later established. Two unrelated boys presented with osteogenesis imperfecta due to point mutations in COL1A1 and were both subsequently found to have a 1bp frameshift deletion in the Dystrophin gene at age 3 and age 15, respectively. The third patient had a diagnosis of pseudoachondroplasia caused by a mutation in the COMP gene and was found to have a deletion of exons 48-50 in Dystrophin at age 9. We discuss the atypical presentation caused by the concomitant presence of 2 conditions affecting the musculoskeletal system, emphasizing aspects that may confound the presentation of a well-characterized disease like DMD. Additional series of patients with DMD and a secondary inherited condition are necessary to establish the natural history in this “double trouble” population. The recognition and accurate diagnosis of patients with two independent genetic disease processes is essential for management, prognosis, genetic risk assessment, and discussion regarding potential therapeutic interventions. PMID:24070816

  3. Entonox® inhalation to reduce pain in common diagnostic and therapeutic outpatient urological procedures: a review of the evidence

    PubMed Central

    Young, A; Ismail, M; Papatsoris, AG; Barua, JM; Calleary, JG; Masood, J

    2012-01-01

    INTRODUCTION Entonox® (50% nitrous oxide and 50% oxygen; BOC Healthcare, Manchester, UK) is an analgesic and anxiolytic agent that is used to successfully reduce pain and anxiety during dental, paediatric and emergency department procedures. In this article we review the application and efficacy of Entonox® in painful local anaesthesia urological procedures by performing a systematic review of the literature. METHODS A MEDLINE® search was performed using the terms ‘nitrous oxide’, ‘Entonox’, ‘prostate biopsy’, ‘flexible cystoscopy’ and ‘extracorporeal shock wave lithotripsy’. English language publications of randomised studies were identified and reviewed. RESULTS The search yielded five randomised studies that investigated the clinical efficacy of Entonox® as an analgesic for day case urological procedures. Three randomised controlled trials (RCTs) investigated Entonox® in transrectal ultrasonography guided prostate biopsy. All three reported significant reductions in pain score in the Entonox® versus control groups. One RCT reported significant reduction in pain during male flexible cystoscopy in the Entonox® group compared with the control group. One RCT, which examined the use of Entonox® during extracorporeal shock wave lithotripsy, found its use significantly decreased the pain score compared with the control group and this was comparable to intravenous pethidine. CONCLUSIONS Evidence from varied adult and paediatric procedures has shown Entonox® to be an effective, safe and patient acceptable form of analgesia. All published studies of its use in urological day case procedures have found it to significantly reduce procedural pain. There is huge potential to use this cheap, safe, effective analgesic in our current practice. PMID:22524905

  4. Additive Manufacturing/Diagnostics via the High Frequency Induction Heating of Metal Powders: The Determination of the Power Transfer Factor for Fine Metallic Spheres

    SciTech Connect

    Rios, Orlando; Radhakrishnan, Balasubramaniam; Caravias, George; Holcomb, Matthew

    2015-03-11

    Grid Logic Inc. is developing a method for sintering and melting fine metallic powders for additive manufacturing using spatially-compact, high-frequency magnetic fields called Micro-Induction Sintering (MIS). One of the challenges in advancing MIS technology for additive manufacturing is in understanding the power transfer to the particles in a powder bed. This knowledge is important to achieving efficient power transfer, control, and selective particle heating during the MIS process needed for commercialization of the technology. The project s work provided a rigorous physics-based model for induction heating of fine spherical particles as a function of frequency and particle size. This simulation improved upon Grid Logic s earlier models and provides guidance that will make the MIS technology more effective. The project model will be incorporated into Grid Logic s power control circuit of the MIS 3D printer product and its diagnostics technology to optimize the sintering process for part quality and energy efficiency.

  5. Additional criteria and procedures for classifying over-the-counter drugs as generally recognized as safe and effective and not misbranded. Final rule.

    PubMed

    2002-01-23

    The Food and Drug Administration (FDA) is issuing a final rule establishing additional criteria and procedures by which over-the- counter (OTC) conditions may become eligible for consideration in the OTC drug monograph system. The criteria and procedures address how OTC drugs initially marketed in the United States after the OTC drug review began in 1972, and OTC drugs without any U.S. marketing experience, can meet the statutory definition of marketing to a "material extent" and "for a material time" and become eligible. If found eligible, the condition would be evaluated for general recognition of safety and effectiveness in accordance with FDA's OTC drug monograph regulations. FDA is also changing the current OTC drug monograph procedures to streamline the process and provide additional information in the review.

  6. The Additive Effects of Values Clarification Training to an Online Goal-Setting Procedure on Measures of Student Retention and Performance

    ERIC Educational Resources Information Center

    Chase, Jared A.

    2010-01-01

    The purpose of this study was to provide individuals with online tutorials to help participants generate strategies to achieve their academic goals and clarify their academic values to assess the additive effects of values clarification training to an online goal-setting training procedure on (1) measures of academic performance and (2) student…

  7. Characteristics of gastrointestinal stromal tumours, diagnostic procedure and therapeutic management and main directions of nursing practice in gastrointestinal stromal tumours

    PubMed Central

    Głuszek, Stanisław; Kozieł, Dorota

    2014-01-01

    Gastrointestinal stromal tumours (GIST) constitute a separate group of mesenchymal neoplasms of the gastrointestinal tract. They have been commonly recognized for a few years, they have created a new problem in medical practice. GIST are more often centred in the stomach. They equally affect female and male patients and occur mainly in patients older than 50 years of age. The clinical picture of the tumour is non-specific. Radical surgical treatment and molecularly targeted therapy with tyrosine kinase inhibitors are used in GIST treatment. Nursing practice with reference to GIST danger is connected with biopsychosocial interventions of perioperative, oncological and palliative procedures and involves the area of health education mainly oriented towards shaping preventive procedures which favour early disease detection and support therapy and recovery. PMID:25784835

  8. Recorded gonorrhoea rates in Denmark, 1900–2010: the impact of clinical testing activity and laboratory diagnostic procedures

    PubMed Central

    Lind, Inga; Hoffmann, Steen

    2015-01-01

    Objectives Assessment of the relations between recorded gonorrhoea rates and clinical testing activity and disposable diagnostic tests. Methods In Denmark, two sources of information on the epidemiology of gonorrhoea are available: (1) a mandatory clinical notification system (since 1867) comprising summary information about geographic distribution, season, age group and gender; in 1994, more detailed anonymous individualised epidemiological information was included; (2) a voluntary countrywide laboratory surveillance system for culture-confirmed cases (since 1957) comprising information about patient's age and gender, infected anatomical sites and medical setting attended. Results Both surveillance systems showed marked simultaneous changes in gonorrhoea rates, although periodically considerable under-reporting or under-diagnosing was demonstrated. The annual incidence of notified cases peaked in 1919 (474/100 000), in 1944 (583/100 000) and in 1972 (344/100 000). Since 1995, the incidence has been at a low endemic level (1.5–10/100 000) and the total male/female incidence ratios were from 3 to 7 times higher than previously recorded. Among approximately 2 million persons tested during 1974–1988 78 213 men and 63 143 women with culture-confirmed gonorrhoea were identified. During this period, pharyngeal sampling was performed in 36% of men and 25% of women with gonorrhoea; pharyngeal gonorrhoea was found in 10% and 16%, respectively; 40% and 30% of these patients had no concomitant urogenital gonorrhoea. Among men with gonorrhoea, 34% were sampled from the rectum; 9% had rectal gonorrhoea, among whom the rectum was the only infected site in 67%. Conclusions Crucial factors for case finding are clinical sampling tradition and appropriate laboratory diagnostic facilities. When case finding is insufficient, a reservoir of asymptomatic rectal or pharyngeal gonorrhoea remains unrecognised. PMID:26621510

  9. Follow-up study of persons who had iodine-131 and other diagnostic procedures during childhood and adolescence

    SciTech Connect

    Hamilton, P.M.; Chiacchierini, R.P.; Kaczmarek, R.G.

    1989-08-01

    A prospective study of 3,503 children and adolescents who received diagnostic doses of iodine-131 was conducted to evaluate the risk of radiation-induced thyroid neoplasia. The exposed group was followed for a total of 93,442 person-years. Thyroid doses received by the exposed group ranged from less than 10 rads to slightly more than 2,000 rads. The majority received less than 100 rads. A group of 2,594 children and adolescents who were not exposed to radioactive iodine comprised the control group for the study. Members of the control group were followed for a total of 66,797 person-years. An elevated risk of malignant thyroid tumors was observed in the exposed group. An increased risk of benign thyroid conditions was also noted in the exposed group. The results described above failed to fulfill the requirements for statistical significance because of the small number of cases but are suggestive of a radiation effect.

  10. The crystallinity of calcium phosphate powders influenced by the conditions of neutralized procedure with citric acid additions

    SciTech Connect

    Li Chengfeng

    2009-05-06

    Calcium phosphate powders with nano-sized crystallinity were synthesized by neutralization using calcium hydroxide and orthophosphoric acid with the assistance of citric acid. The influence of processing parameters, such as free or additive citric acid, synthetic temperature and ripening time, on the crystallinity of hydroxyapatite were investigated. The results of X-ray diffraction and microstructure observations showed that the crystallinity and morphology of nano-sized hydroxyapatite particles were influenced by the presence or absence of citric acid. It was found that the crystallinities and crystallite sizes of hydroxyapatite powders prepared with the additive citric acid increased with increasing synthetic temperature and ripening time. Especially, the crystallinities of (h k 0) planes were raised and more homogeneously grown particles were obtained with increasing synthetic temperature.

  11. An economic and rapid diagnostic procedure for the detection of salmonella/shigella using the polyvalent salmonella phage O-1.

    PubMed

    Fey, H; Bürgi, E; Margadant, A; Boller, E

    1978-01-01

    An easy, rapid and economic two-step procedure is described for the detection of Salmonella/Shigella. In the first step the susceptibility of suspected colonies for the phage O-1 of FELIX and CALLOW is tested. Positive cultures are serologically confirmed. The test is performed on Triple Sugar Iron Agar and lasts 4-6 hrs. Phage negative cultures which are lactose- and sucrose negative are tested for lysine decarboxylase and, if Shigella is possible (i.e. in human material on primary plates), for indol production and motility in a semisolid tryptophane agar. Of 22880 Salmonella straine 21977, i.e. 96.1% were phage-sensitive. Strains belonging to certain O-groups (OE) or species are lysed at a lower percentage. However, since they are lysine decarboxylase positive they are not lost and can be submitted to a serological examination.

  12. Population radiation dose from diagnostic nuclear medicine procedures in the Tehran population in 1999-2003: striking changes in only one decade.

    PubMed

    Tabeie, Faraj; Mohammadi, Hooshang; Asli, Isa Neshandar

    2013-02-01

    Use of unsealed radiopharmaceuticals in Iran's nuclear medicine centers has expanded rapidly in the last decade. As part of a nationwide survey, this study was undertaken to estimate the radiation risk due to the diagnostic nuclear medicine procedures performed in Tehran in 1999-2003. During the five years of the study, the data of 101,540 yearly examinations of diagnostic nuclear medicine were obtained for 34 (out of 40) active nuclear medicine centers in Tehran. The patients studied were aged 1 y, 5 y, 10 y, 15 y, and adults (>15 y). Compared to an earlier investigation in 1989 (which was published in 1995), striking changes were found to be occurring in the trends of nuclear medicine in Tehran in a matter of a decade. The frequency of cardiac examinations increased from less than 1% in 1989 to 43.2% (mean of 5 y) in 2003; thyroid examinations, with the relative frequency of higher than 80% in 1989, decreased to 26.7% in the current investigation (averaged for 2001); and the number of overall examinations per 1,000 population of Tehran increased from 1.9 in 1989 to 8.8 in this study (about fourfold). The decrease in relative frequency of thyroid examinations could be attributed to the lower referral policy (mainly by specialists), decreased incidence of goiter due to implementation of programs for iodine enrichment diets, introduction of fine needle aspiration (FNA), and sonography techniques for diagnosis of thyroid disease. The large increase in relative frequency of cardiac examinations could be due to the increase in the number of single photon emission computerized tomography (SPECT) systems in recent years as compared to 1989 in Tehran. The collective effective dose increased from 400 (person-Sv) in 1999 to 529 (person-Sv) in 2003, and the effective dose per capita increased from 34.80 μSv in 1999 to 44.06 μSv in 2003 (average, 35.60 μSv).

  13. The role of a labial salivary gland biopsy in the diagnostic procedure for Sjögren’s syndrome; a study of 94 cases

    PubMed Central

    van Stein-Callenfels, Dewi; Tan, Jonathan; Bloemena, Elisabeth; van Vugt, Richard M.; Voskuyl, Alexandre E.; Santana, Nathalie T.Y.

    2014-01-01

    Objectives: The purpose of the present study is to examine the role of the outcome of the labial salivary gland biopsy (LSGB) in the diagnostic procedure of patients suspected of suffering from Sjögren’s syndrome (SS). Material and Methods: In a retrospective study the result of histopathological assessment of 94 consecutively taken labial salivary gland biopsies has been examined. For the diagnosis of SS the American-European Consensus Group classification (AECG, 2002) have been used. The outcome of the assessment has been discussed in relation to a recently reported classification provided by the American College of Rheumatology (ACR, 2012). Results: In the 94 LSGBs support for a diagnosis of SS has been encountered in 24 out of 26 patients with SS. In the 68 patients with a negative diagnosis of SS only six positive LSGBs were observed. The sensitivity of the labial biopsy amounted 0.92; the specificity was 0.91, while the positive predictive value and the negative predictive value amounted 0.80 and 0.97 respectively. LSGBs taken by or on the request of the departments of Rheumatology or Internal Medicine had a significant higher yield compared to LSGBs taken in other clinical departments. Conclusions: The LSGB may play a role in the diagnostic procedure of Sjögren’s syndrome when using either the AECG classification or the ACR classification. A LSGB should preferably taken after counseling for the possible presence of SS by a department of Rheumatology or Internal Medicine since the yield of such biopsies is much higher than in patients who have not been counseled by these departments prior to the taking of a LSGB. When using the ACR classification, a positive serologic result and a positive ocular test make the taking of a LSGB redundant. Only in case of a negative serologic outcome or a negative result of the ocular test a LSGB is indicated. Since both the serologic test and the ocular test carry hardly any morbidity, these tests should, indeed, be

  14. Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures

    SciTech Connect

    Brady, Samuel; Yoshizumi, Terry; Toncheva, Greta; Frush, Donald; and others

    2010-09-15

    the main axis of the CT beam. The consistency in dose response difference allowed for a tissue specific correction to be applied. Once corrected, the average film response agreed to better than 3%(SD{+-}2%) for the CTDI scans, and for the anthropomorphic phantom scans: 3%(SD{+-}3%) for the lungs, 5%(SD{+-}3%) for the liver, and 4%(SD{+-}3%) for the kidneys. Additionally, XRQA film measured a heterogeneous dose distribution within the organ volumes. The extent of the dose distribution heterogeneity was not measurable with the TLDs due to the limitation on the number of TLDs loadable in the regions of the phantom organs. In this regard, XRQA film demonstrated an advantage over the TLD method by discovering a 15% greater maximum dose to lung in a region unmeasured by TLDs. Conclusions: The films demonstrated a lower sensitivity to absorbed dose measurements due to the geometric inefficiency of measuring dose from a beam situated end-on to the film. Once corrected, the film demonstrated equivalent dose measurement accuracy as TLD detectors with the added advantage of relatively simple measurement of high-resolution dose distributions throughout organ volumes.

  15. Neurological Diagnostic Tests and Procedures

    MedlinePlus

    ... Thermography uses infrared sensing devices to measure small temperature changes between the two sides of the body ... called ultrasound scanning or sonography, uses high-frequency sound waves to obtain images inside the body. Neurosonography ( ...

  16. Monitoring Impact of a Pesticide Treatment on Bacterial Soil Communities by Metabolic and Genetic Fingerprinting in Addition to Conventional Testing Procedures

    PubMed Central

    Engelen, Bert; Meinken, Kristin; von Wintzingerode, Friedrich; Heuer, Holger; Malkomes, Hans-Peter; Backhaus, Horst

    1998-01-01

    Herbogil (dinoterb), a reference herbicide, the mineral oil Oleo (paraffin oil used as an additive to herbicides), and Goltix (metamitron) were taken as model compounds for the study of impacts on microbial soil communities. After the treatment of soil samples, effects on metabolic sum parameters were determined by monitoring substrate-induced respiration (SIR) and dehydrogenase activity, as well as carbon and nitrogen mineralization. These conventional ecotoxicological testing procedures are used in pesticide registration. Inhibition of biomass-related activities and stimulation of nitrogen mineralization were the most significant effects caused by the application of Herbogil. Even though Goltix and Oleo were used at a higher dosage (10 times higher), the application of Goltix resulted in smaller effects and the additive Oleo was the least-active compound, with minor stimulation of test parameters at later observation times. The results served as a background for investigation of the power of “fingerprinting” methods in microbial ecology. Changes in catabolic activities induced by treatments were analyzed by using the 95 carbon sources provided by the BIOLOG system. Variations in the complex metabolic fingerprints demonstrated inhibition of many catabolic pathways after the application of Herbogil. Again, the effects of the other compounds were expressed at much lower levels and comprised stimulations as well as inhibitions. Testing for significance by a multivariate t test indicated that the sensitivity of this method was similar to the sensitivities of the conventional testing procedures. The variation of sensitive carbon sources, as determined by factor weights at different observation times, indicated the dynamics of the community shift induced by the Herbogil treatment in more detail. DNA extractions from soil resulted in a collection of molecules representing the genetic composition of total bacterial communities. Distinct and highly reproducible

  17. Sensitivity of Symptomatology Versus Diagnostic Procedures and Concentration of CEA and CA19–9 in the Early Detection of Colorectal Cancer

    PubMed Central

    Vukobrat-Bijedic, Zora; Husic-Selimovic, Azra; Bijedic, Nina; Mujkic, Admir; Sofic, Amela; Gogov, Bisera; Mehmedovic, Amila; Bjelogrlic, Ivana; Glavas, Sanjin; Djuran, Aleksandra

    2014-01-01

    important symptom. We can say that after the age of 74 years cancer of the rectum and sigmoid is more common in men and in women dominate sigma and other locations in the colon. In patients under the 70 years of age with short time of bleeding, cancer predominates in rectum. In patients younger than 63 years can be concluded that weight loss is greater than 8 kg follows rectal cancer. In patients with bleeding that lasted one month or more as classifier occurring the age and gender. Patients younger than 74 years have rectal cancer, while older than 73 years have cancer at other sites. In women these locations are sigma and rectum. Conclusion: Based on this study we can conclude that regardless of the technical advances in medicine must pay special attention to the symptoms that doctors will refer to the localization of the tumor, stenosis of the intestine and possibly metastasis. Key words: Colorectal cancer, diagnostic procedures, concentration of CEA and CA19-9. PMID:24825931

  18. Mild cognitive impairment (MCI) in medical practice: a critical review of the concept and new diagnostic procedure. Report of the MCI Working Group of the European Consortium on Alzheimer's Disease.

    PubMed

    Portet, F; Ousset, P J; Visser, P J; Frisoni, G B; Nobili, F; Scheltens, Ph; Vellas, B; Touchon, J

    2006-06-01

    Mild cognitive impairment (MCI) was proposed as a nosological entity referring to elderly people with mild cognitive deficit but no dementia. MCI is a heterogeneous clinical entity with multiple sources of heterogeneity. The concept of MCI was reviewed and a diagnostic procedure with three different stages was proposed by the European Consortium on Alzheimer's Disease Working Group on MCI. Firstly, MCI should correspond to cognitive complaints coming from the patients or their families; the reporting of a relative decline in cognitive functioning during the past year by a patient or informant; cognitive disorders as evidenced by clinical evaluation; absence of major repercussions on daily life; and absence of dementia. These criteria, similar to those defined during an international workshop in Stockholm, make it possible to identify an MCI syndrome, which is the first stage of the diagnostic procedure. Secondly, subtypes of MCI had to be recognised. Finally, the aetiopathogenic subtype could be identified. Identifying patients at a high risk for progression to dementia and establishing more specific and adapted therapeutic strategies at an early stage, together with more structured overall management, is made possible by the diagnostic procedure proposed.

  19. A comparison of the boomerang wire vascular access management system versus manual compression alone during percutaneous diagnostic and interventional cardiovascular procedures.

    PubMed

    Echeverria, Angela; Krajcer, Zvonimir

    2016-01-01

    Vascular closure devices allow for early sheath removal, allowing for earlier patient mobilization The Boomerang vascular access management system does not alter arterial integrity for future interventions Access site complications provide significant morbidity in diagnostic and therapeutic interventions.

  20. Combined complementary plasma diagnostics to characterize a 2f plasma with additional DC current with conditioning effects at the chamber wall

    NASA Astrophysics Data System (ADS)

    Klick, Michael; Rothe, Ralf; Baek, Kye Hyun; Lee, Eunwoo

    2016-09-01

    Multiple frequencies and DC current used in a low-pressure plasma rf discharge result in an increased complexity. This needs plasma diagnostics applied, in particular in a plasma process chamber. That is done under manufacturing conditions which restrict the applicable plasma diagnostics to non-invasive methods with small footprint. So plasma chamber parameters, optical emission spectroscopy (OES), and self-excited electron spectroscopy (SEERS) are used to characterize the plasma and to understand chamber wall conditioning effects in an Ar plasma. The parameters are classified according to their origin--the region they are representative for. The center ion density is estimated from the DC current and compared to the SEERS electron density reflecting the electron density close to that at the chamber wall. The conditioning effects are caused by Si sputtering at a Si wafer changing the chamber wall state only when the chamber is clean, subsequent plasmas in the same chamber are not affected in that way. Through the combination of the complementary methods it can be shown that the chamber wall condition finally changes the radial plasma density distribution. Also the heating of electrons in the sheath is shown to be influenced by conditioning effects.

  1. Isoflurane versus sevoflurane with interscalene block for shoulder arthroscopic procedures: Value of process capability indices as an additional tool for data analysis

    PubMed Central

    Tantry, Thrivikrama Padur; Karanth, Harish; Shenoy, Sunil P; Ayya, Shreekantha V; Shetty, Pramal K; Adappa, Karunakara K

    2016-01-01

    Background and Aims: Hypotensive anaesthesia reduces intra-articular bleed and promotes visualisation during arthroscopy. The haemodynamic effects of inhalational agents isoflurane and sevoflurane were studied extensively, and both were found to reduce mean arterial pressures (MBP) to an equivalent magnitude. We investigated the relative ability of isoflurane vis-a-vis sevoflurane to maintain the target systolic blood pressure (SBP) in patients undergoing shoulder arthroscopic procedures. Methods: In a prospective randomised study, 59 patients in two groups of 30 and 29 patients each received concomitant general anaesthesia (1.2–1.5 MAC of isoflurane and sevoflurane) and interscalene brachial plexus block. Nitrous oxide was used in both groups. Intraoperatively, serial blood pressure recordings of SBP, diastolic blood pressure (DBP), MBP and heart rates were done at every 3rd min intervals. The manipulations needed to achieve target SBP (T = 90 mmHg) for optimal arthroscopic visualisation and treat unacceptable hypotensive episodes were noted. Conventional statistical tests and process capability index (PCI) evaluation were both deployed for data analysis. Results: Lower mean SBP and DBPs were recorded for isoflurane patients as compared to sevoflurane (P < 0.05, for mean, maximum and minimum recordings). Higher mean heart rates were recorded for isoflurane (P < 0.05). PCIs indicated that isoflurane was superior to sevoflurane in the ease of achieving target SBP of 90 mmHg as well as maintaining blood pressures in the range of 80–100 mmHg. Conclusion: Isoflurane provides better intraoperative haemodynamic status vis-a-vis sevoflurane in patients undergoing shoulder arthroscopic surgery with preliminary interscalene blockade. The PCI can be a useful additional medical data analysis tool. PMID:28003697

  2. Prevalence and monthly distribution of head lice using two diagnostic procedures in several age groups in Uberlândia, State of Minas Gerais, Southeastern Brazil.

    PubMed

    Borges, Raquel; Silva, Juliana J; Rodrigues, Rosângela M; Mendes, Júlio

    2007-01-01

    Some epidemiological characteristics of head lice, Pediculus capitis, were studied using two procedures: cut hair analysis and head inspection. Higher prevalence rates were observed in the middle and at the end of the school terms. Both procedures indicated that children were the main reservoir for this type of pediculosis in Uberlândia.

  3. PROcess Based Diagnostics PROBE

    NASA Technical Reports Server (NTRS)

    Clune, T.; Schmidt, G.; Kuo, K.; Bauer, M.; Oloso, H.

    2013-01-01

    Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

  4. A Statistical Test of the Validity of Diagnostic Categories Used in Childhood Language Disorders: Implications for Assessment Procedures. Papers and Reports on Child Language Development, No. 4.

    ERIC Educational Resources Information Center

    Rosenthal, William S.; And Others

    This paper examines the validity of diagnostic categories frequently used to classify children with severe language disorders by determining the relationship of the categories to independently derived developmental, psychological, and medical variables. It is argued that the classification systems currently available too often fail to achieve the…

  5. Usefulness of Cardiac MIBG Scintigraphy, Olfactory Testing and Substantia Nigra Hyperechogenicity as Additional Diagnostic Markers for Distinguishing between Parkinson’s Disease and Atypical Parkinsonian Syndromes

    PubMed Central

    Fujita, Hiroaki; Numao, Ayaka; Watanabe, Yuji; Uchiyama, Tomoyuki; Miyamoto, Tomoyuki; Miyamoto, Masayuki; Hirata, Koichi

    2016-01-01

    Background We aimed to evaluate the utility of the combined use of cardiac 123I-metaiodobenzylguanidine (MIBG) scintigraphy, olfactory testing, and substantia nigra (SN) hyperechogenicity on transcranial sonography (TCS) in differentiating Parkinson’s disease (PD) from atypical parkinsonian syndromes (APSs), such as multiple system atrophy (MSA) and progressive supranuclear palsy (PSP). Methods Cardiac MIBG scintigraphy, card-type odor identification testing (Open Essence (OE), Wako, Japan), and TCS were performed with 101 patients with PD and 38 patients with APSs (MSA and PSP). Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of these batteries for diagnosing PD from APSs. The diagnostic accuracy of the three tests was also assessed among patients at the early disease stage (drug-naïve patients with a disease duration of 3 years or less). Results In differentiating PD from APSs, the area under the ROC curve was 0.74 (95% CI, 0.65–0.83), 0.8 (95% CI, 0.73–0.87), and 0.75 (95% CI, 0.67–0.82) for TCS, cardiac MIBG scintigraphy, and olfactory testing, respectively. The diagnostic sensitivity and specificity were 53.1% and 91.7%, respectively, for TCS, 70.3% and 86.8%, respectively, for cardiac MIBG scintigraphy, 58.4% and 76.3%, respectively, for OE. Among early-stage patients, sensitivity and specificity were 50.0% and 93.8%, respectively, for TCS, 57.1% and 87.5%, respectively, for cardiac MIBG scintigraphy, and 54.8% and 79.2%, respectively, for OE. At least one positive result from 3 tests improved sensitivity (86.1%) but decreased specificity (63.2%). In contrast, at least 2 positive results from 3 tests had good discrimination for both early-stage patients (50.0% sensitivity and 93.8% specificity) and patients overall (57.8% sensitivity and 95.8% specificity). Positive results for all 3 tests yielded 100% specificity but low sensitivity (25%). Conclusions At least 2 positive results from among

  6. A Critical Review of Screening and Diagnostic Instruments for Autism Spectrum Disorders in People with Sensory Impairments in Addition to Intellectual Disabilities

    ERIC Educational Resources Information Center

    de Vaan, Gitta; Vervloed, Mathijs P. J.; Hoevenaars-van den Boom, Marella; Antonissen, Anneke; Knoors, Harry; Verhoeven, Ludo

    2016-01-01

    Instruments that are used for diagnosing of, or screening for, autism spectrum disorder (ASD) may not be applicable to people with sensory disabilities in addition to intellectual disabilities. First, because they do not account for equifinality, the possibility that different conditions may lead to the same outcome. Second, because they do not…

  7. Patient satisfaction and quality of care at four diagnostic imaging procedures: mammography, double-contrast barium enema, abdominal ultrasonography and vaginal ultrasonography.

    PubMed

    Loken, K; Steine, S; Laerum, E

    1999-01-01

    The objective of this study was to measure patient satisfaction and to investigate the practical implications of monitoring the quality of care at four radiology procedures. A survey was conducted immediately after the examinations in eight radiology departments: 550 patients attending for mammography, 110 for double-contrast barium enema (DCBE), 97 for abdominal ultrasonography and 90 for vaginal ultrasonography. Outcome measures were seven questionnaire scales: pain, emotional distress, information received, staff's punctuality and technical ability, facilities, and general satisfaction. Response rate was 87 %. Multivariate regression analysis showed significant differences between procedures on all scales (p < 0.001). Differences considered to be of practical importance, i. e. >/= 7 scale points, were detected on five of the scales. Mammography and DCBE caused the most pain, and vaginal US and DCBE caused the most distress. The US procedures entailed dissatisfaction with information about the procedures. The DCBE patients recorded dissatisfaction with the staff's lack of punctuality, and these and the mammography patients recorded dissatisfaction with the facilities. The findings indicate a potential for improving patients' experiences. Several aspects of care, i. e. pain management, attention to the patient's emotional concerns, explanation of procedures, punctuality and quality of the facilities, can be improved.

  8. SCAI/CCAS/SPA expert consensus statement for anesthesia and sedation practice: Recommendations for patients undergoing diagnostic and therapeutic procedures in the pediatric and congenital cardiac catheterization laboratory.

    PubMed

    Odegard, Kirsten C; Vincent, Robert; Baijal, Rahul; Daves, SuAnne; Gray, Robert; Javois, Alex; Love, Barry; Moore, Phil; Nykanen, David; Riegger, Lori; Walker, Scott G; Wilson, Elizabeth C

    2016-11-15

    Current practice of sedation and anesthesia for patients undergoing pediatric congenital cardiac catheterization laboratory (PCCCL) procedures is known to vary among institutions, a multi-society expert panel with representatives from the Congenital Heart Disease Council of the Society for Cardiovascular Angiography and Interventions (SCAI), the Society for Pediatric Anesthesia (SPA) and the Congenital Cardiac Anesthesia Society (CCAS) was convened to evaluate the types of sedation and personnel necessary for procedures performed in the PCCCL. The goal of this panel was to provide practitioners and institutions performing these procedures with guidance consistent with national standards and to provide clinicians and institutions with consensus-based recommendations and the supporting references to encourage their application in quality improvement programs. Recommendations can neither encompass all clinical circumstances nor replace the judgment of individual clinicians in the management of each patient. The science of medicine is rooted in evidence, and the art of medicine is based on the application of this evidence to the individual patient. This expert consensus statement has adhered to these principles for optimal management of patients requiring sedation and anesthesia. What follows are recommendations for patient monitoring in the PCCCL regardless of whether minimal or no sedation is being used or general anesthesia is being provided by an anesthesiologist. © 2016 Wiley Periodicals Inc.

  9. [Optimisation of diagnostics and differential diagnostics disseminated pulmonary tuberculosis].

    PubMed

    Demikhova, O V; Karpina, N L; Lepekha, L N; Bagirov, M A; Amansakhedov, R B

    2012-01-01

    One of the reasons of dramatic situation with tuberculosis in Russia is untimely diagnostics of tuberculosis. The aim of the study was to identify the causes of diagnostic mistakes when we deal with disseminated pulmonary tuberculosis at current stage and to modernize the diagnostic process. The analysis of the diagnostic activity of the consultative diagnostic center of Central Tuberculosis Research Institute of Russian Academy Medical Sciences for 2011 was performed with special attention on the results of the survey of 505 patients with pulmonary dissemination. The frequency of discrepancies of disseminated pulmonary tuberculosis diagnostics was 96.1%. Based on the studies carried out the main causes diagnostic mistakes in patients with disseminated pulmonary tuberculosis were determined. New directions of improving of tuberculosis diagnostics were developed: overall high-technology examination of patient, adherence to the diagnostic procedure, developed by consultative diagnostic center of Central Tuberculosis Research Institute (CTRI), timely performing fiber-optic bronchoscopy with complex biopsy and diagnostic surgery procedures, further training of primary health care doctors. Implementation of proposed activities will significantly (by 3-5 times) reduce the time for diagnostics of respiratory system disease.

  10. Establishment of an on-site diagnostic procedure for detection of orf virus from oral lesions of Japanese serows (Capricornis crispus) by loop-mediated isothermal amplification

    PubMed Central

    INOSHIMA, Yasuo; TAKASU, Masaki; ISHIGURO, Naotaka

    2016-01-01

    Orf virus infection has been prevalent continuously in the population of wild Japanese serows (Capricornis crispus), goat-like grazing cloven-hoofed mammal species that live mainly in mountainous areas of Japan. Currently, definitive diagnosis of infection requires time-consuming laboratory work. To diagnose rapidly on-site, we developed a field-friendly procedure for the detection of orf virus from oral cavity lesions. DNA was extracted from goat saliva spiked with orf virus as a proxy for Japanese serows by a commercial kit without the use of electricity, and the quality of the extracted DNA was evaluated by conventional polymerase chain reaction (PCR). Extracted DNA was amenable to DNA amplification, the same as when extracted in a laboratory. Next, to find optimal conditions for DNA amplification by loop-mediated isothermal amplification (LAMP), Bst and Csa DNA polymerases and 3 colorimetric indicators for visual diagnosis, hydroxy naphthol blue (HNB), malachite green and D-QUICK, were compared using a portable cordless incubator. The combination of Bst or Csa DNA polymerase with HNB was found to be easiest for visual diagnosis by the naked eye, and viral DNA was successfully amplified from all orf virus strains used. These results suggest that the procedure established here can work completely on-site and can be useful for definitive diagnosis and differentiation of orf virus infection in Japanese serows in remote mountainous areas. PMID:27628591

  11. Current Trends and Healthcare Resource Usage in the Hospital Treatment of Primary Malignant Brain Tumor in Japan: A National Survey Using the Diagnostic Procedure Combination Database (J-ASPECT Study-Brain Tumor)

    PubMed Central

    YOSHIMOTO, Koji; KADA, Akiko; KUGA, Daisuke; HATAE, Ryusuke; MURATA, Hideki; AKAGI, Yojiro; NISHIMURA, Kunihiro; KUROGI, Ryota; NISHIMURA, Ataru; HATA, Nobuhiro; MIZOGUCHI, Masahiro; SAYAMA, Tetsuro; IIHARA, Koji

    2016-01-01

    We conducted this study to clarify the current trends and healthcare resource usage in the treatment of inpatients with primary malignant brain tumors. The Diagnostic Procedure Combination (DPC) data of all inpatients treated between 2013 and 2014 in the 370 core and branch hospitals enrolled in the Japanese Neurosurgical Society training program were collected. DPC is a discharge abstract and administrative claims database of inpatients. We assessed 6,142 primary, malignant brain tumor patients. Patient information, diagnostic information, treatment procedure, and healthcare resource usage were analyzed. Chemotherapy was the most frequent treatment (27% of cases), followed by surgery (13%) and surgery + chemo-radiotherapy (11%). Temozolomide (TMZ), the most frequently used chemotherapeutic drug, was administered to 1,236 patients. Concomitant TMZ and radiotherapy was administered to 816 patients, and was performed according to the Stupp regimen in many cases. The mean length of hospital stay (LOS) was 16 days, and the mean medical cost was 1,077,690 yen. The average medical cost of TMZ-only treatment was 1,138,620 yen whilst it was 4,424,300 yen in concomitant TMZ patients. The LOS was significantly shorter in high-volume than in low-volume hospitals, and the medical cost was higher in hospitals treating 21–50 patients compared to those treating 1–10 patients. However, the direct medical cost of TMZ treatment was the same across different volume hospitals. This is the first report of current trends and healthcare resource usage in the treatment of primary malignant brain tumor inpatients in the TMZ era in Japan. PMID:27680329

  12. Current Trends and Healthcare Resource Usage in the Hospital Treatment of Primary Malignant Brain Tumor in Japan: A National Survey Using the Diagnostic Procedure Combination Database (J-ASPECT Study-Brain Tumor).

    PubMed

    Yoshimoto, Koji; Kada, Akiko; Kuga, Daisuke; Hatae, Ryusuke; Murata, Hideki; Akagi, Yojiro; Nishimura, Kunihiro; Kurogi, Ryota; Nishimura, Ataru; Hata, Nobuhiro; Mizoguchi, Masahiro; Sayama, Tetsuro; Iihara, Koji

    2016-11-15

    We conducted this study to clarify the current trends and healthcare resource usage in the treatment of inpatients with primary malignant brain tumors. The Diagnostic Procedure Combination (DPC) data of all inpatients treated between 2013 and 2014 in the 370 core and branch hospitals enrolled in the Japanese Neurosurgical Society training program were collected. DPC is a discharge abstract and administrative claims database of inpatients. We assessed 6,142 primary, malignant brain tumor patients. Patient information, diagnostic information, treatment procedure, and healthcare resource usage were analyzed. Chemotherapy was the most frequent treatment (27% of cases), followed by surgery (13%) and surgery + chemo-radiotherapy (11%). Temozolomide (TMZ), the most frequently used chemotherapeutic drug, was administered to 1,236 patients. Concomitant TMZ and radiotherapy was administered to 816 patients, and was performed according to the Stupp regimen in many cases. The mean length of hospital stay (LOS) was 16 days, and the mean medical cost was 1,077,690 yen. The average medical cost of TMZ-only treatment was 1,138,620 yen whilst it was 4,424,300 yen in concomitant TMZ patients. The LOS was significantly shorter in high-volume than in low-volume hospitals, and the medical cost was higher in hospitals treating 21-50 patients compared to those treating 1-10 patients. However, the direct medical cost of TMZ treatment was the same across different volume hospitals. This is the first report of current trends and healthcare resource usage in the treatment of primary malignant brain tumor inpatients in the TMZ era in Japan.

  13. Attendance at Cervical Cancer Screening and Use of Diagnostic and Therapeutic Procedures on the Uterine Cervix Assessed from Individual Health Insurance Data (Belgium, 2002-2006)

    PubMed Central

    Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy

    2014-01-01

    Objective To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. Methods The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25–64 that had a Pap smear within the last 3 years. Results Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004–2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25–34 year old women, 67% for those aged 35–39 years, and decreased to 44% in the age group of 60–64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004–2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. Conclusion The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population. PMID:24690620

  14. Integrated diagnostics

    NASA Technical Reports Server (NTRS)

    Hunthausen, Roger J.

    1988-01-01

    Recently completed projects in which advanced diagnostic concepts were explored and/or demonstrated are summarized. The projects begin with the design of integrated diagnostics for the Army's new gas turbine engines, and advance to the application of integrated diagnostics to other aircraft subsystems. Finally, a recent project is discussed which ties together subsystem fault monitoring and diagnostics with a more complete picture of flight domain knowledge.

  15. Additive Similarity Trees

    ERIC Educational Resources Information Center

    Sattath, Shmuel; Tversky, Amos

    1977-01-01

    Tree representations of similarity data are investigated. Hierarchical clustering is critically examined, and a more general procedure, called the additive tree, is presented. The additive tree representation is then compared to multidimensional scaling. (Author/JKS)

  16. 12 CFR 509.104 - Additional procedures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... this part shall be filed with the Director, to the attention of the Secretary. (h) Presence of cameras and other recording devices. The use of cameras and other recording devices, other than those used...

  17. Collective effective dose from diagnostic radiology in Ukraine.

    PubMed

    Stadnyk, L; Shalopa, O; Nosyk, O

    2015-07-01

    The frequencies and effective doses for the most common X-ray diagnostic examinations in Ukraine were assessed in the frame of the European Commission (EC) Study on European Population Doses from Medical Exposure (Dose Datamed 2). The average effective doses for all radiographic procedures were estimated using the ODS-60 software (Finland). The estimation of the effective doses for the chest film fluorography was carried out from the results of own representative measurements with thermoluminescent (TL) dosimetry and a standard Alderson-Rando phantom. The effective doses for fluoroscopy procedures were assessed using the Russian guidelines for estimation of effective doses. For all other X-ray examinations and procedures [computed tomography (CT), angiography and interventional procedures], typical effective dose values were taken from the EC Guidance RP154. The most frequently performed in Ukraine is chest film fluorography, with 389 examinations per 1000 population annually, reflecting in the greatest contribution to the total collective effective dose (CED) of 428 mSv per 1000 population (44 %). The total frequency and CED from all X-ray diagnostic examinations and procedures were estimated to be 1218 examinations and 1060 mSv per 1000 populations, respectively. The expected additional cancer risk from X-ray diagnostic examinations and interventional procedures is 2680 cases per year, with 1200 of them due to the contribution of chest fluorography. The main important action in radiation protection of patients in diagnostic radiology is the organisation of the monitoring of patient doses for different types of X-ray diagnostic examinations and replacement of chest film fluorography with digital X-ray systems.

  18. Recent advances in diagnostic bronchoscopy

    PubMed Central

    Ong, Philip G.; Debiane, Labib G.

    2016-01-01

    The field of diagnostic bronchoscopy has been revolutionized in the last decade primarily with the advent of endobronchial ultrasound (EBUS) but also with the addition of multiple different techniques for “guided-bronchoscopy”. These advances have had a substantial impact in the management of lung cancer with bronchoscopy now providing both diagnosis and mediastinal staging in a single procedure. EBUS has, in fact, become the first choice for staging of the mediastinum over cervical mediastinoscopy (CM). Although EBUS is now a well-established technique, there are continuous efforts from the scientific community to improve its diagnostic performance, and these will be reviewed in this manuscript. The term “guided-bronchoscopy” was recently coined to describe a myriad of techniques that guide our bronchoscopes or bronchoscopic tools into the periphery of the lungs in addition to our conventional fluoroscopy. Electromagnetic and non-electromagnetic navigation, thin and ultrathin scopes, as well as radial-probe EBUS have collectively increased our yield for smaller peripheral lung lesions and continue to evolve. Despite this improved diagnostic yield, there is still ample room for improvement and newer techniques are under way. With new therapies available for patients with interstitial lung disease, achieving a specific histologic diagnosis is now of paramount importance. Given the high morbidity and mortality of surgical biopsies, bronchoscopic cryobiopsy is being rapidly adopted as a safer and effective alternative, and it is likely going to play a major role in the management of these diseases in the near future. This manuscript we will focus on recent advances in EBUS, guided-bronchoscopy, and the use of cryobiopsy. PMID:28149581

  19. Production Pathways and Separation Procedures for High-Diagnostic-Value Activation Species, Fission Products, and Actinides Required for Preparation of Realistic Synthetic Post-Detonation Nuclear Debris: Status Report and FY16 Project Plan

    SciTech Connect

    Faye, S. A.; Shaughnessy, D. A.

    2015-08-19

    The objective of this project is to provide a comprehensive study on the production routes and chemical separation requirements for activation products, fission products, and actinides required for the creation of realistic post-detonation surrogate debris. Isotopes that have been prioritized by debris diagnosticians will be examined for their ability to be produced at existing irradiation sources, production rates, and availability of target materials, and chemical separation procedures required to rapidly remove the products from the bulk target matrix for subsequent addition into synthetic debris samples. The characteristics and implications of the irradiation facilities on the isotopes of interest will be addressed in addition to a summary of the isotopes that are already regularly produced. This is a planning document only.

  20. [Thalassaemia diagnostics].

    PubMed

    Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P

    2014-01-01

    The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.

  1. Cable Diagnostic Focused Initiative

    SciTech Connect

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  2. [Intolerance to food additives: an update].

    PubMed

    Cardinale, F; Mangini, F; Berardi, M; Sterpeta Loffredo, M; Chinellato, I; Dellino, A; Cristofori, F; Di Domenico, F; Mastrototaro, M F; Cappiello, A; Centoducati, T; Carella, F; Armenio, L

    2008-12-01

    Contrary to common believing, the prevalence of the intolerance to food additives in the general population is rather low. Nowadays many doubts persist with regard both to the pathogenetic mechanisms and to the clinical and diagnostic aspects in this field. Symptoms due to, or exacerbated from, food additives usually involve non-IgE-mediate mechanisms (pseudo-allergic reactions, PAR) and are usually less severe of those induced by food allergy. The most frequent clinical feature of the intolerance to food additives still remains the urticaria-angioedema syndrome, although these substances are really involved only in a minority of patients. Other possible clinical features include anaphylaxis, atopic eczema, behaviour disturbances, asthma and non-allergic rhinitis. The diagnostic approach consists in diary cards, reporting symptoms and food habits, elimination diet and double blinded placebo-controlled oral challenge with suspected additives. However, such procedure still remains poorly standardized and numerous uncertainties persist with regard to optimal conditions for performing and interpret the challenge results. The therapeutic approach consists in the exclusion of foods and products containing the additive involved, and, in patients not compliant to the diet, in treatment with symptomatic drugs.

  3. Children’s Exposure to Diagnostic Medical Radiation and Cancer Risk: Epidemiologic and Dosimetric Considerations

    PubMed Central

    Linet, Martha S.; Kim, Kwang pyo; Rajaraman, Preetha

    2009-01-01

    While the etiology of most childhood cancers is largely unknown, epidemiologic studies have consistently found an association between exposure to medical radiation during pregnancy and risk of childhood cancer in offspring. The relation between early life diagnostic radiation exposure and occurrence of pediatric cancer risks is less clear. This review summarizes current and historical estimated doses for common diagnostic radiologic procedures as well as the epidemiologic literature on the role of maternal prenatal, children’s postnatal and parental preconception diagnostic radiologic procedures on subsequent risk of childhood malignancies Risk estimates are presented according to factors such as the year of birth of the child, trimester and medical indication for the procedure, and the number of films taken. The paper also discusses limitations of the methods employed in epidemiologic studies to assess pediatric cancer risks, the effects on clinical practice of the results reported from the epidemiologic studies, and clinical and public health policy implications of the findings. Gaps in understanding and additional research needs are identified. Important research priorities include nationwide surveys to estimate fetal and childhood radiation doses from common diagnostic procedures, and epidemiologic studies to quantify pediatric and lifetime cancer risks from prenatal and early childhood exposures to diagnostic radiography, computed tomography, and fluoroscopically-guided procedures. PMID:19083224

  4. Combining principles of Cognitive Load Theory and diagnostic error analysis for designing job aids: Effects on motivation and diagnostic performance in a process control task.

    PubMed

    Kluge, Annette; Grauel, Britta; Burkolter, Dina

    2013-03-01

    Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control.

  5. Astrovirus Diagnostics

    PubMed Central

    Pérot, Philippe; Lecuit, Marc; Eloit, Marc

    2017-01-01

    Various methods exist to detect an astrovirus infection. Current methods include electron microscopy (EM), cell culture, immunoassays, polymerase chain reaction (PCR) and various other molecular approaches that can be applied in the context of diagnostic or in surveillance studies. With the advent of metagenomics, novel human astrovirus (HAstV) strains have been found in immunocompromised individuals in association with central nervous system (CNS) infections. This work reviews the past and current methods for astrovirus detection and their uses in both research laboratories and for medical diagnostic purposes. PMID:28085120

  6. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  7. 42 CFR 410.33 - Independent diagnostic testing facility.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... performs a test he or she is authorized by the State to perform, or an independent diagnostic testing... furnishes diagnostic procedures in a physician's office. (2) Exceptions. The following diagnostic tests that... Drug Administration. (ii) Diagnostic tests personally furnished by a qualified audiologist as...

  8. Diagnostic imaging in pediatric emergencies

    SciTech Connect

    Heller, R.M.; Coulam, C.M.; Allen, J.H.; Fleischer, A.; Lee, G.S.; Kirchner, S.G.; James A.E. Jr.

    1980-07-01

    Evaluation of pediatric emergencies by diagnostic imaging technics can involve both invasive and noninvasive procedures. Nuclear medicine, conventional radiography, ultrasound, computerized axial tomography, and xeroradiography are the major nonangiographic diagnostic technics available for patient evaluation. We will emphasize the use of computerized axial tomography, nuclear medicine, xeroradiography, and ultrasound in the evaluation of emergencies in the pediatric age group. Since the radiologist is the primary consultant with regard to diagnostic imaging, his knowledge of these modulities can greatly influence patient care and clinical results.

  9. Knowledge based jet engine diagnostics

    NASA Technical Reports Server (NTRS)

    Jellison, Timothy G.; Dehoff, Ronald L.

    1987-01-01

    A fielded expert system automates equipment fault isolation and recommends corrective maintenance action for Air Force jet engines. The knowledge based diagnostics tool was developed as an expert system interface to the Comprehensive Engine Management System, Increment IV (CEMS IV), the standard Air Force base level maintenance decision support system. XMAM (trademark), the Expert Maintenance Tool, automates procedures for troubleshooting equipment faults, provides a facility for interactive user training, and fits within a diagnostics information feedback loop to improve the troubleshooting and equipment maintenance processes. The application of expert diagnostics to the Air Force A-10A aircraft TF-34 engine equipped with the Turbine Engine Monitoring System (TEMS) is presented.

  10. Revisiting Tversky's diagnosticity principle

    PubMed Central

    Evers, Ellen R. K.; Lakens, Daniël

    2013-01-01

    Similarity is a fundamental concept in cognition. In 1977, Amos Tversky published a highly influential feature-based model of how people judge the similarity between objects. The model highlights the context-dependence of similarity judgments, and challenged geometric models of similarity. One of the context-dependent effects Tversky describes is the diagnosticity principle. The diagnosticity principle determines which features are used to cluster multiple objects into subgroups. Perceived similarity between items within clusters is expected to increase, while similarity between items in different clusters decreases. Here, we present two pre-registered replications of the studies on the diagnosticity effect reported in Tversky (1977). Additionally, one alternative mechanism that has been proposed to play a role in the original studies, an increase in the choice for distractor items (a substitution effect, see Medin et al., 1995), is examined. Our results replicate those found by Tversky (1977), revealing an average diagnosticity-effect of 4.75%. However, when we eliminate the possibility of substitution effects confounding the results, a meta-analysis of the data provides no indication of any remaining effect of diagnosticity. PMID:25161638

  11. Cotton-based Diagnostic Devices

    PubMed Central

    Lin, Shang-Chi; Hsu, Min-Yen; Kuan, Chen-Meng; Wang, Hsi-Kai; Chang, Chia-Ling; Tseng, Fan-Gang; Cheng, Chao-Min

    2014-01-01

    A good diagnostic procedure avoids wasting medical resources, is easy to use, resists contamination, and provides accurate information quickly to allow for rapid follow-up therapies. We developed a novel diagnostic procedure using a “cotton-based diagnostic device” capable of real-time detection, i.e., in vitro diagnostics (IVD), which avoids reagent contamination problems common to existing biomedical devices and achieves the abovementioned goals of economy, efficiency, ease of use, and speed. Our research reinforces the advantages of an easy-to-use, highly accurate diagnostic device created from an inexpensive and readily available U.S. FDA-approved material (i.e., cotton as flow channel and chromatography paper as reaction zone) that adopts a standard calibration curve method in a buffer system (i.e., nitrite, BSA, urobilinogen and uric acid assays) to accurately obtain semi-quantitative information and limit the cross-contamination common to multiple-use tools. Our system, which specifically targets urinalysis diagnostics and employs a multiple biomarker approach, requires no electricity, no professional training, and is exceptionally portable for use in remote or home settings. This could be particularly useful in less industrialized areas. PMID:25393975

  12. Food additives

    PubMed Central

    Spencer, Michael

    1974-01-01

    Food additives are discussed from the food technology point of view. The reasons for their use are summarized: (1) to protect food from chemical and microbiological attack; (2) to even out seasonal supplies; (3) to improve their eating quality; (4) to improve their nutritional value. The various types of food additives are considered, e.g. colours, flavours, emulsifiers, bread and flour additives, preservatives, and nutritional additives. The paper concludes with consideration of those circumstances in which the use of additives is (a) justified and (b) unjustified. PMID:4467857

  13. Rocket Engine Oscillation Diagnostics

    NASA Technical Reports Server (NTRS)

    Nesman, Tom; Turner, James E. (Technical Monitor)

    2002-01-01

    Rocket engine oscillating data can reveal many physical phenomena ranging from unsteady flow and acoustics to rotordynamics and structural dynamics. Because of this, engine diagnostics based on oscillation data should employ both signal analysis and physical modeling. This paper describes an approach to rocket engine oscillation diagnostics, types of problems encountered, and example problems solved. Determination of design guidelines and environments (or loads) from oscillating phenomena is required during initial stages of rocket engine design, while the additional tasks of health monitoring, incipient failure detection, and anomaly diagnostics occur during engine development and operation. Oscillations in rocket engines are typically related to flow driven acoustics, flow excited structures, or rotational forces. Additional sources of oscillatory energy are combustion and cavitation. Included in the example problems is a sampling of signal analysis tools employed in diagnostics. The rocket engine hardware includes combustion devices, valves, turbopumps, and ducts. Simple models of an oscillating fluid system or structure can be constructed to estimate pertinent dynamic parameters governing the unsteady behavior of engine systems or components. In the example problems it is shown that simple physical modeling when combined with signal analysis can be successfully employed to diagnose complex rocket engine oscillatory phenomena.

  14. Crew procedures development techniques

    NASA Technical Reports Server (NTRS)

    Arbet, J. D.; Benbow, R. L.; Hawk, M. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.

    1975-01-01

    The study developed requirements, designed, developed, checked out and demonstrated the Procedures Generation Program (PGP). The PGP is a digital computer program which provides a computerized means of developing flight crew procedures based on crew action in the shuttle procedures simulator. In addition, it provides a real time display of procedures, difference procedures, performance data and performance evaluation data. Reconstruction of displays is possible post-run. Data may be copied, stored on magnetic tape and transferred to the document processor for editing and documentation distribution.

  15. Procedural knowledge

    NASA Technical Reports Server (NTRS)

    Georgeff, Michael P.; Lansky, Amy L.

    1986-01-01

    Much of commonsense knowledge about the real world is in the form of procedures or sequences of actions for achieving particular goals. In this paper, a formalism is presented for representing such knowledge using the notion of process. A declarative semantics for the representation is given, which allows a user to state facts about the effects of doing things in the problem domain of interest. An operational semantics is also provided, which shows how this knowledge can be used to achieve particular goals or to form intentions regarding their achievement. Given both semantics, the formalism additionally serves as an executable specification language suitable for constructing complex systems. A system based on this formalism is described, and examples involving control of an autonomous robot and fault diagnosis for NASA's Space Shuttle are provided.

  16. Diagnostics development plan for ZR.

    SciTech Connect

    Hanson, David Lester

    2003-09-01

    The Z Refurbishment (ZR) Project is a program to upgrade the Z machine at SNL with modern durable pulsed power technology, providing additional shot capacity and improved reliability as well as advanced capabilities for both pulsed x-ray production and high pressure generation. The development of enhanced diagnostic capabilities is an essential requirement for ZR to meet critical mission needs. This report presents a comprehensive plan for diagnostic instrument and infrastructure development for the first few years of ZR operation. The focus of the plan is on: (1) developing diagnostic instruments with high spatial and temporal resolution, capable of low noise operation and survival in the severe EMP, bremsstrahlung, and blast environments of ZR; and (2) providing diagnostic infrastructure improvements, including reduced diagnostic trigger signal jitter, more and flexible diagnostic line-of-sight access, and the capability for efficient exchange of diagnostics with other laboratories. This diagnostic plan is the first step in an extended process to provide enhanced diagnostic capabilities for ZR to meet the diverse programmatic needs of a broad range of defense, energy, and general science programs of an international user community into the next decade.

  17. A randomized controlled trial to assess the impact of dietary energy sources, feed supplements, and the presence of super-shedders on the detection of Escherichia coli O157:H7 in feedlot cattle using different diagnostic procedures.

    PubMed

    Cernicchiaro, Natalia; Pearl, David L; McEwen, Scott A; Zerby, Henry N; Fluharty, Francis L; Loerch, Steve C; Kauffman, Michael D; Bard, Jaime L; LeJeune, Jeffrey T

    2010-09-01

    Alteration of the gastro-intestinal tract through manipulation of cattle diets has been proposed as a preharvest control measure to reduce fecal shedding of Escherichia coli O157:H7. The objective of this study was to examine the effects of the energy source's moisture content (high moisture corn and dry whole-shelled corn), two natural feed supplements (Saccaromyces cerevisiae boulardii CNCM 1079-Levucell and Aspergillus oryzae-Amaferm), and two levels of vitamin A (2200 IU/kg and no supplementation) on the fecal excretion of E. coli O157:H7 in naturally infected cattle. One hundred sixty-eight Angus-cross beef steers were randomly allocated to 24 pens, and each pen was assigned 1 of 12 dietary treatments in a randomized complete block design. E. coli O157:H7 was detected by rectoanal mucosal swab (RAMS) and fecal grab samples using immunomagnetic separation (IMS) and standard microbiological techniques. On the basis of multivariable multilevel logistic regression models, we found a statistically significant (p < 0.05) increase in the prevalence of E. coli O157:H7 in animals fed dry whole-shelled corn in models based on fecal-IMS, and this effect was increased if a super-shedding animal (shedding > 10(4) colony forming units of E. coli O157:H7 per gram of feces) was present in the pen at the time of testing relative to animals fed high moisture corn and nonexposed to super-shedders. However, in similar models based on RAMS-IMS testing, the effect of corn type on the prevalence of E. coli O157:H7 varied with the type of feed additive used. Being exposed to a super-shedding pen-mate also increased the odds of being positive to E. coli O157:H7 in the RAMS-IMS models. These models demonstrate that the impact of different supplements may vary with the diagnostic test used, and that further research into the biological significance of differences between RAMS- and fecal-IMS test results is warranted.

  18. Salivary diagnostics

    PubMed Central

    Lee, J.M.; Garon, E.; Wong, D.T.

    2010-01-01

    The ability to monitor health status, disease onset and progression, and treatment outcome through non-invasive means is a most desirable goal in the health care promotion and delivery. There are three prerequisites to materialize this goal: specific biomarkers associated with a health or disease state; a non-invasive approach to detect and monitor the biomarkers; and the technologies to discriminate the biomarkers. A national initiative catalyzed by the National Institute of Dental & Craniofacial Research (NIDCR) has created a roadmap to achieve these goals through the use of oral fluids as the diagnostic medium to scrutinize the health and/or disease status of individuals. Progress has shown this is an ideal opportunity to bridge state of the art saliva-based biosensors, optimized to disease discriminatory salivary biomarkers, for diagnostic applications. Oral fluid being the ‘mirror of body’ is a perfect medium to be explored for health and disease surveillance. The translational applications and opportunities are enormous. PMID:19627522

  19. Food additives

    MedlinePlus

    ... or natural. Natural food additives include: Herbs or spices to add flavor to foods Vinegar for pickling ... Certain colors improve the appearance of foods. Many spices, as well as natural and man-made flavors, ...

  20. Rotorcraft Diagnostics

    NASA Technical Reports Server (NTRS)

    Haste, Deepak; Azam, Mohammad; Ghoshal, Sudipto; Monte, James

    2012-01-01

    Health management (HM) in any engineering systems requires adequate understanding about the system s functioning; a sufficient amount of monitored data; the capability to extract, analyze, and collate information; and the capability to combine understanding and information for HM-related estimation and decision-making. Rotorcraft systems are, in general, highly complex. Obtaining adequate understanding about functioning of such systems is quite difficult, because of the proprietary (restricted access) nature of their designs and dynamic models. Development of an EIM (exact inverse map) solution for rotorcraft requires a process that can overcome the abovementioned difficulties and maximally utilize monitored information for HM facilitation via employing advanced analytic techniques. The goal was to develop a versatile HM solution for rotorcraft for facilitation of the Condition Based Maintenance Plus (CBM+) capabilities. The effort was geared towards developing analytic and reasoning techniques, and proving the ability to embed the required capabilities on a rotorcraft platform, paving the way for implementing the solution on an aircraft-level system for consolidation and reporting. The solution for rotorcraft can he used offboard or embedded directly onto a rotorcraft system. The envisioned solution utilizes available monitored and archived data for real-time fault detection and identification, failure precursor identification, and offline fault detection and diagnostics, health condition forecasting, optimal guided troubleshooting, and maintenance decision support. A variant of the onboard version is a self-contained hardware and software (HW+SW) package that can be embedded on rotorcraft systems. The HM solution comprises components that gather/ingest data and information, perform information/feature extraction, analyze information in conjunction with the dependency/diagnostic model of the target system, facilitate optimal guided troubleshooting, and offer

  1. Whipple Procedure

    MedlinePlus

    ... Blog Patient Education Pancreas News Basics of Pancreatic Cancer FAQs The Pancreas Types of Tumors Causes Hereditary Factors Known Risk Factors Symptoms and Side Effects Screening Questions Palliative Care Diagnosis Diagnostic Tests Metastasis Staging Treatment and Care Surgical ...

  2. Training for advanced endoscopic procedures.

    PubMed

    Feurer, Matthew E; Draganov, Peter V

    2016-06-01

    Advanced endoscopy has evolved from diagnostic ERCP to an ever-increasing array of therapeutic procedures including EUS with FNA, ablative therapies, deep enteroscopy, luminal stenting, endoscopic suturing and endoscopic mucosal resection among others. As these procedures have become increasingly more complex, the risk of potential complications has also risen. Training in advanced endoscopy involves more than obtaining a minimum number of therapeutic procedures. The means of assessing a trainee's competence level and ability to practice independently continues to be a matter of debate. The use of quality indicators to measure performance levels may be beneficial as more advanced techniques and procedures become available.

  3. FEL-accelerator related diagnostics

    SciTech Connect

    Kevin Jordan; David Douglas; Stephen V. Benson; Pavel Evtuschenko

    2007-08-02

    Free Electron Lasers (FEL) present a unique set of beam parameters to the diagnostics suite. The FEL requires characterization of the full six dimensional phase space of the electron beam at the wiggler and accurate alignment of the electron beam to the optical mode of the laser. In addition to the FEL requirements on the diagnostics suite, the Jefferson Lab FEL is operated as an Energy Recovered Linac (ERL) which imposes additional requirements on the diagnostics. The ERL aspect of the Jefferson Lab FEL requires that diagnostics operate over a unique dynamic range and operate with simultaneous transport of the accelerated and energy recovered beams. This talk will present how these challenges are addressed at the Jefferson Lab FEL.

  4. GENOSENSE Diagnostics GmbH.

    PubMed

    Schneeberger, Christian

    2004-07-01

    GENOSENSE Diagnostics GmbH, a company specialized in preventive genetic diagnostics, has committed itself to applying molecular medical knowledge to realizing the vision of individual, preventive and patient-tailored medicine. GENOSENSE offers a unique line of preventive genomic diagnostic profiles. Each profile focuses on a carefully selected set of polymorphisms associated with particular diseases or physiologic imbalances. GENOSENSE does not only provide the genetic test results, but highly capable medical experts 'translate' the results into a clinical language and assist the customer with established support regarding their medical interpretation. In addition, the company provides academic institutions and pharmaceutical companies with turnkey solutions for research-based projects.

  5. Procedural pediatric dermatology.

    PubMed

    Metz, Brandie J

    2013-04-01

    Due to many factors, including parental anxiety, a child's inability to understand the necessity of a procedure and a child's unwillingness to cooperate, it can be much more challenging to perform dermatologic procedures in children. This article reviews pre-procedural preparation of patients and parents, techniques for minimizing injection-related pain and optimal timing of surgical intervention. The risks and benefits of general anesthesia in the setting of pediatric dermatologic procedures are discussed. Additionally, the surgical approach to a few specific types of birthmarks is addressed.

  6. Viral Hemorrhagic Fever Diagnostics

    PubMed Central

    Racsa, Lori D.; Kraft, Colleen S.; Olinger, Gene G.; Hensley, Lisa E.

    2016-01-01

    There are 4 families of viruses that cause viral hemorrhagic fever (VHF), including Filoviridae. Ebola virus is one virus within the family Filoviridae and the cause of the current outbreak of VHF in West Africa. VHF-endemic areas are found throughout the world, yet traditional diagnosis of VHF has been performed in large reference laboratories centered in Europe and the United States. The large amount of capital needed, as well as highly trained and skilled personnel, has limited the availability of diagnostics in endemic areas except in conjunction with governmental and nongovernmental entities. However, rapid diagnosis of VHF is essential to efforts that will limit outbreaks. In addition, increased global travel suggests VHF diagnoses may be made outside of the endemic areas. Thus, understanding how to diagnose VHF is imperative for laboratories worldwide. This article reviews traditional and current diagnostic modalities for VHF. PMID:26354968

  7. Advances in diagnostic radiology.

    PubMed

    Runge, Val M

    2010-12-01

    Recent advances in diagnostic radiology are discussed on the basis of current publications in Investigative Radiology. Publications in the journal during 2009 and 2010 are reviewed, evaluating developments by modality and anatomic region. Technological advances continue to play a major role in the evolution and clinical practice of diagnostic radiology, and as such constitute a major publication focus. In the past 2 years, this includes advances in both magnetic resonance and computed tomography (in particular, the advent of dual energy computed tomography). An additional major focus of publications concerns contrast media, and in particular continuing research involving nephrogenic systemic fibrosis, its etiology, and differentiation of the gadolinium chelates on the basis of in vivo stability.

  8. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  9. Additive Manufacturing of Medical Models--Applications in Rhinology.

    PubMed

    Raos, Pero; Klapan, Ivica; Galeta, Tomislav

    2015-09-01

    In the paper we are introducing guidelines and suggestions for use of 3D image processing SW in head pathology diagnostic and procedures for obtaining physical medical model by additive manufacturing/rapid prototyping techniques, bearing in mind the improvement of surgery performance, its maximum security and faster postoperative recovery of patients. This approach has been verified in two case reports. In the treatment we used intelligent classifier-schemes for abnormal patterns using computer-based system for 3D-virtual and endoscopic assistance in rhinology, with appropriate visualization of anatomy and pathology within the nose, paranasal sinuses, and scull base area.

  10. Potlining Additives

    SciTech Connect

    Rudolf Keller

    2004-08-10

    In this project, a concept to improve the performance of aluminum production cells by introducing potlining additives was examined and tested. Boron oxide was added to cathode blocks, and titanium was dissolved in the metal pool; this resulted in the formation of titanium diboride and caused the molten aluminum to wet the carbonaceous cathode surface. Such wetting reportedly leads to operational improvements and extended cell life. In addition, boron oxide suppresses cyanide formation. This final report presents and discusses the results of this project. Substantial economic benefits for the practical implementation of the technology are projected, especially for modern cells with graphitized blocks. For example, with an energy savings of about 5% and an increase in pot life from 1500 to 2500 days, a cost savings of $ 0.023 per pound of aluminum produced is projected for a 200 kA pot.

  11. Phosphazene additives

    DOEpatents

    Harrup, Mason K; Rollins, Harry W

    2013-11-26

    An additive comprising a phosphazene compound that has at least two reactive functional groups and at least one capping functional group bonded to phosphorus atoms of the phosphazene compound. One of the at least two reactive functional groups is configured to react with cellulose and the other of the at least two reactive functional groups is configured to react with a resin, such as an amine resin of a polycarboxylic acid resin. The at least one capping functional group is selected from the group consisting of a short chain ether group, an alkoxy group, or an aryloxy group. Also disclosed are an additive-resin admixture, a method of treating a wood product, and a wood product.

  12. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    PubMed

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics.

  13. Distribution of certain drug products by registered blood establishments and comprehensive hemophilia diagnostic treatment centers that qualify as health care entities; Prescription Drug Marketing Act of 1987; Prescription Drug Amendments of 1992; policies, requirements and administrative procedures. Final rule.

    PubMed

    2008-10-09

    The Food and Drug Administration (FDA) is amending its regulations to allow certain registered blood establishments and comprehensive hemophilia diagnostic treatment centers that are also health care entities to distribute certain drug products. The final rule amends limited provisions of the regulations implementing the Prescription Drug Marketing Act of 1987 (PDMA), as modified by the Prescription Drug Amendments of 1992 (PDA). These regulations, among other things, restrict the sale, purchase, or trade of, or the offer to sell, purchase, or trade, prescription drugs purchased by hospitals and other health care entities.

  14. [Novel methods for dementia diagnostics].

    PubMed

    Wiltfang, J

    2015-04-01

    Novel diagnostic methods, such as cerebrospinal fluid-based neurochemical dementia diagnostics (CSF-NDD) and [18F] amyloid positron emission tomography (PET) are meanwhile recommended for specific indications by international guidelines for the improved early and differential diagnostics of multigenic (sporadic) Alzheimer's dementia (AD). In the case of CSF-NDD the German neuropsychiatric guidelines have already been validated on the S3 level of evidence (http://www.DGPPN.de) and the additional consideration of [18F] amyloid-PET in the current update of the guidelines is to be expected. By means of CSF-NDD and/or [18F] amyloid-PET a predictive diagnosis of incipient (preclinical) AD is also possible for patients at high risk for AD who are in prodromal stages, such as mild cognitive impairment (MCI). As accompanying (secondary) preventive therapy of AD cannot be offered a predictive molecular dementia diagnostics is not recommended by the German neuropsychiatric dementia guidelines (http://www.DGPPN.de). However, novel diagnostic approaches, which offer molecular positive diagnostics of AD have already gained high relevance in therapy research as they allow promising preventive treatment avenues to be validated directly in the clinical trial. Moreover, future blood-based dementia diagnostics by means of multiplex assays is becoming increasingly more feasible; however, so far corresponding proteomic or epigenetic assays could not be consistently validated in independent studies.

  15. Appropriate use of diagnostic imaging

    SciTech Connect

    Palmer, P.E.S.; Cockshott, W.P.

    1984-11-16

    This article discusses ways in which more appropriate use can be made of roentgenography with a resulting decrease in radiation doses to the patient population. The authors recommend that fewer films be made and that traditional roentgenography be replaced with endoscopy, ultrasound, computerized tomography, or angiography where appropriate. They also recommend that medical schools and medical subspecialty groups study the World Health Organization document which provides indications for diagnostic imaging, the choice of procedure and the limitations of each.

  16. [Molecular diagnostics in neuropathology].

    PubMed

    Dietmaier, W; Lorenz, J; Riemenschneider, M J

    2015-03-01

    As in only few other areas of oncology, molecular markers in neurooncology have become an integral part of clinical decision-making. This development is driven by a bustling scientific activity exploring the molecular basis and pathogenesis of human brain tumors. In addition, a high percentage of brain tumor patients are included in clinical studies in which molecular markers are assessed and linked with clinical informativeness. First steps towards more differentiated therapeutic strategies against brain tumors have thus been taken. The implementation in the clinical and diagnostic routine requires a detailed knowledge and a close collaboration between all medical disciplines involved.

  17. Procedural learning and dyslexia.

    PubMed

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken.

  18. Procedural sedation analgesia

    PubMed Central

    Sheta, Saad A

    2010-01-01

    The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades.Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA). The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED) usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation) is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy. PMID:20668560

  19. Microarray Technologies in Fungal Diagnostics.

    PubMed

    Rupp, Steffen

    2017-01-01

    Microarray technologies have been a major research tool in the last decades. In addition they have been introduced into several fields of diagnostics including diagnostics of infectious diseases. Microarrays are highly parallelized assay systems that initially were developed for multiparametric nucleic acid detection. From there on they rapidly developed towards a tool for the detection of all kind of biological compounds (DNA, RNA, proteins, cells, nucleic acids, carbohydrates, etc.) or their modifications (methylation, phosphorylation, etc.). The combination of closed-tube systems and lab on chip devices with microarrays further enabled a higher automation degree with a reduced contamination risk. Microarray-based diagnostic applications currently complement and may in the future replace classical methods in clinical microbiology like blood cultures, resistance determination, microscopic and metabolic analyses as well as biochemical or immunohistochemical assays. In addition, novel diagnostic markers appear, like noncoding RNAs and miRNAs providing additional room for novel nucleic acid based biomarkers. Here I focus an microarray technologies in diagnostics and as research tools, based on nucleic acid-based arrays.

  20. SDQ: discriminative validity and diagnostic potential

    PubMed Central

    Silva, Thaysa B. F.; Osório, Flávia L.; Loureiro, Sonia R.

    2015-01-01

    The Strengths and Difficulties Questionnaire (SDQ) was designed to screen for behavioral problems in youths based on cutoff points that favor the instrument's diagnostic sensitivity. The present study aimed to analyze the discriminative validity of the SDQ to identify behavioral difficulties and prosocial resources in school-age children compared with the diagnostic data collected by the corresponding sections of the Development and Well-being Assessment (DAWBA). In addition, new cutoff points that value specificity were defined for the SDQ scales, exploring its diagnostic potential. This study was conducted in Brazil and assessed a community convenience sample that consisted of 120 children aged 6–12 years who were not under psychological/psychiatric treatment. The mothers of the participants also completed a sociodemographic questionnaire. Descriptive statistics were used to clinically characterize the sample. A ROC curve was used to assess the discriminant validity of the SDQ, and new cutoff points were established to maximize the instrument's specificity. The new cutoff points enabled a significant increase in specificity without a significant loss of sensitivity, which favors approaches based on measures of screening and diagnosis yet does not damage the instrument's screening capacity. The following increases were observed: 100% for the depressive disorder scale (cutoff point = 7), 95.1% for the generalized anxiety disorder scale (cutoff point = 7), 46.6% for the conduct disorder scale (cutoff point = 6), 19.2% for the hyperactive disorder scale (cutoff point = 8), and 27.6% for the antisocial personality disorder scale (cutoff point = 6). A cutoff point of 8 was applied to the prosocial behavior scale, which exhibited a 62.1% increase in specificity. The use of more specific cutoff points generated more accurate results and favored SDQ's use, particularly in contexts of care that require more precise and faster procedures for identification of problems

  1. Far infrared fusion plasma diagnostics

    SciTech Connect

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-01-01

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer's importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA's CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  2. Beam diagnostics

    SciTech Connect

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-08-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the {open_quotes}Booster{close_quotes} and {open_quotes}ATLAS{close_quotes} linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates.

  3. Nucleic acid probes in diagnostic medicine

    NASA Technical Reports Server (NTRS)

    Oberry, Phillip A.

    1991-01-01

    The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

  4. Laboratory Diagnostics and Quality of Blood Collection

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Picheth, Geraldo; Guidi, Gian Cesare

    2015-01-01

    Summary Diagnostic blood samples collected by phlebotomy are the most common type of biological specimens drawn and sent to laboratory medicine facilities for being analyzed, thus supporting caring physicians in patient diagnosis, follow-up and/or therapeutic monitoring. Phlebotomy, a relatively invasive medical procedure, is indeed critical for the downstream procedures accomplished either in the analytical phase made in the laboratory or in the interpretive process done by the physicians. Diagnosis, management, treatment of patients and ultimately patient safety itself can be compromised by poor phlebotomy quality. We have read with interest a recent article where the authors addressed important aspects of venous blood collection for laboratory medicine analysis. The authors conducted a phlebotomy survey based on the Clinical and Laboratory Standard Institute (CLSI) H03-A6 document (presently replaced by the GP41-A6 document) in three government hospitals in Ethiopia to evaluate 120 professionals (101 non-laboratory professionals vs. 19 laboratory professionals) as regards the venous blood collection practice. The aim of this mini (non-systematic) review is to both take a cue from the above article and from current practices we had already observed in other laboratory settings, and discuss four questionable activities performed by health care professionals during venous blood collection. We refer to: i) diet restriction assessment; ii) puncture site cleansing; iii) timing of tourniquet removal and; iv) mixing specimen with additives. PMID:28356839

  5. Surgical Procedures. Second Edition. Teacher Edition.

    ERIC Educational Resources Information Center

    Baker, Beverly; And Others

    This teacher's guide contains 13 units of instruction for a course that will prepare students with the entry-level competencies needed by a surgical technologist. The course covers the following topics: introduction to surgical procedures; diagnostic procedures; general surgery; gastrointestinal surgery; obstetrics and gynecological surgery;…

  6. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  7. Dental Procedures.

    PubMed

    Ramponi, Denise R

    2016-01-01

    Dental problems are a common complaint in emergency departments in the United States. There are a wide variety of dental issues addressed in emergency department visits such as dental caries, loose teeth, dental trauma, gingival infections, and dry socket syndrome. Review of the most common dental blocks and dental procedures will allow the practitioner the opportunity to make the patient more comfortable and reduce the amount of analgesia the patient will need upon discharge. Familiarity with the dental equipment, tooth, and mouth anatomy will help prepare the practitioner for to perform these dental procedures.

  8. Invasive mycoses: diagnostic challenges.

    PubMed

    Ostrosky-Zeichner, Luis

    2012-01-01

    Despite the availability of newer antifungal drugs, outcomes for patients with invasive fungal infections (IFIs) continue to be poor, in large part due to delayed diagnosis and initiation of appropriate antifungal therapy. Standard histopathologic diagnostic techniques are often untenable in at-risk patients, and culture-based diagnostics typically are too insensitive or nonspecific, or provide results after too long a delay for optimal IFI management. Newer surrogate markers of IFIs with improved sensitivity and specificity are needed to enable earlier diagnosis and, ideally, to provide prognostic information and/or permit therapeutic monitoring. Surrogate assays should also be accessible and easy to implement in the hospital. Several nonculture-based assays of newer surrogates are making their way into the medical setting or are currently under investigation. These new or up-and-coming surrogates include antigens/antibodies (mannan and antimannan antibodies) or fungal metabolites (d-arabinitol) for detection of invasive candidiasis, the Aspergillus cell wall component galactomannan used to detect invasive aspergillosis, or the fungal cell wall component and panfungal marker β-glucan. In addition, progress continues with use of polymerase chain reaction- or other nucleic acid- or molecular-based assays for diagnosis of either specific or generic IFIs, although the various methods must be better standardized before any of these approaches can be more fully implemented into the medical setting. Investigators are also beginning to explore the possibility of combining newer surrogate markers with each other or with more standard diagnostic approaches to improve sensitivity, specificity, and capacity for earlier diagnosis, at a time when fungal burden is still relatively low and more responsive to antifungal therapy.

  9. Optical Diagnostics in Medicine

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor

    2003-03-01

    Light has a unique potential for non-invasive tissue diagnosis. The relatively short wavelength of light allows imaging of tissue at the resolution of histopathology. While strong multiple scattering of light in tissue makes attainment of this resolution difficult for thick tissues, most pathology emanates from epithelial surfaces. Therefore, high-resolution diagnosis of many important diseases may be achieved by transmitting light to the surface of interest. The recent fiber-optic implementation of technologies that reject multiple scattering, such as confocal microscopy and optical low coherence interferometry, have brought us one step closer to realizing non-invasive imaging of architectural and cellular features of tissue. Optical coherence tomography (OCT) can produce high-resolution cross-sectional images of biological structures. Clinical OCT studies conducted in the gastrointestinal tract and cardiovascular system have shown that OCT is capable of providing images of the architectural (> 20 µm) microanatomy of a variety of epithelial tissues, including the layered structure of squamous epithelium and arterial vessels. Fine Needle Aspiration- Low Coherence Interferometry (FNA-LCI) is another optical diagnostics technique, which is a suitable solution to increase the effectiveness of the FNA procedures. LCI is capable of measuring depth resolved (axial, z) tissue structure, birefringence, flow (Doppler shift), and spectra at a resolution of several microns. Since LCI systems are fiber-optic based, LCI probes may easily fit within the bore of a fine gauge needle, allowing diagnostic information to be obtained directly from the FNA biopsy site. Fiber optic spectrally encoded confocal microscopy (SECM) is a new confocal microscopy method, which eliminates the need for rapid beam scanning within the optical probe. This advance enables confocal microscopy to be performed through small diameter probes and will allow assessment of internal human tissues in vivo at

  10. Short Nuss bar procedure

    PubMed Central

    2016-01-01

    The Nuss procedure is now the preferred operation for surgical correction of pectus excavatum (PE). It is a minimally invasive technique, whereby one to three curved metal bars are inserted behind the sternum in order to push it into a normal position. The bars are left in situ for three years and then removed. This procedure significantly improves quality of life and, in most cases, also improves cardiac performance. Previously, the modified Ravitch procedure was used with resection of cartilage and the use of posterior support. This article details the new modified Nuss procedure, which requires the use of shorter bars than specified by the original technique. This technique facilitates the operation as the bar may be guided manually through the chest wall and no additional stabilizing sutures are necessary. PMID:27747185

  11. [Diagnostic Management of Exophthalmos].

    PubMed

    Klingenstein, A; Hintschich, C

    2017-01-01

    Exophthalmos is a common and important symptom in orbital consultation. It can be either uni- or bilateral. A wide spectrum of benign and malignant diseases has to be considered and evaluated for differential diagnosis, in order to maintain complete ocular function and to lead the patient to adequate therapy. Exophthalmos can be accompanied by variable symptoms, ranging from neurogenic or myogenic to corneal alterations. Symptoms at presentation depend on the underlying disease and may manifest systemically. Interdisciplinary teamwork is essential for diagnostics and therapy of exophthalmos. In addition to ophthalmological routine diagnostics, various supplementary examinations are available which are of importance for disease monitoring. Exact radiological imaging is important for the detailed visualisation of the pathology, surgery as well as treatment planning. Magnetic resonance imaging (MRI) and computed tomography (CT) are the standard imaging techniques used. Contrast enhancement and specific sequences can answer specific problems in detail. Combined positron emission tomography (PET) with CT permits evaluation of metabolic and morphological data and is employed in diagnosis of meningioma, lymphoma and metastases. In summary, the reader should learn important differential diagnoses and accompanying symptoms of exophthalmos, thus enabling essential clinical examinations and adequate imaging.

  12. Diagnostic errors in interactive telepathology.

    PubMed

    Stauch, G; Schweppe, K W; Kayser, K

    2000-01-01

    Telepathology (TP) as a service in pathology at a distance is now widely used. It is integrated in the daily workflow of numerous pathologists. Meanwhile, in Germany 15 departments of pathology are using the telepathology technique for frozen section service; however, a common recognised quality standard in diagnostic accuracy is still missing. In a first step, the working group Aurich uses a TP system for frozen section service in order to analyse the frequency and sources of errors in TP frozen section diagnoses for evaluating the quality of frozen section slides, the important components of image quality and their influences an diagnostic accuracy. The authors point to the necessity of an optimal training program for all participants in this service in order to reduce the risk of diagnostic errors. In addition, there is need for optimal cooperation of all partners involved in TP service.

  13. Total cholesterol performance of Abell–Levy–Brodie–Kendall reference measurement procedure: Certification of Japanese in-vitro diagnostic assay manufacturers through CDC’s Cholesterol Reference Method Laboratory Network☆

    PubMed Central

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Kiyama, Masahiko; Yokoyama, Shinji; Kayamori, Yuzo; Koyama, Isao; Nishimura, Kunihiro; Nakai, Michikazu; Dasti, Mahnaz; Vesper, Hubert W.; Teramoto, Tamio; Miyamoto, Yoshihiro

    2015-01-01

    Background Accurate measurement of total cholesterol (TC) is important for cardiovascular disease risk management. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform Abell–Levy–Brodie–Kendall (AK) reference measurement procedure (RMP) for TC as a secondary reference method, and implement Certification Protocol for Manufacturers. Japanese CRMLN laboratory at Osaka performed the AK RMP for 22 years, and conducted TC certification for reagent/calibrator/instrument systems of six Japanese manufacturers every 2 years for 16 years. Osaka TC performance was examined and compared to CDC’s reference values. Methods AK RMP involved sample hydrolysis, cholesterol extraction, and determination of cholesterol levels by spectrophotometry. The Certification Protocol for Manufacturers includes comparison with AK RMP using at least 40 fresh specimens. Demonstration of average bias ≤3% and total coefficient of variation ≤3% qualified an analytical system for certification. Results In the AK RMP used in the Osaka CRMLN laboratory, the regression equation for measuring TC was y (Osaka) = 1.000x (CDC) + 0.032 (n = 619, R2 = 1.000). Six Japanese manufacturers had allowable performance for certification. Conclusions The AK RMP for TC measurement was accurate, precise, and stable for 22 years. Six Japanese manufacturers were certified for 16 years. PMID:25818239

  14. Numerical Boundary Condition Procedures

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Topics include numerical procedures for treating inflow and outflow boundaries, steady and unsteady discontinuous surfaces, far field boundaries, and multiblock grids. In addition, the effects of numerical boundary approximations on stability, accuracy, and convergence rate of the numerical solution are discussed.

  15. Pediatric Procedural Pain

    ERIC Educational Resources Information Center

    Blount, Ronald L.; Piira, Tiina; Cohen, Lindsey L.; Cheng, Patricia S.

    2006-01-01

    This article reviews the various settings in which infants, children, and adolescents experience pain during acute medical procedures and issues related to referral of children to pain management teams. In addition, self-report, reports by others, physiological monitoring, and direct observation methods of assessment of pain and related constructs…

  16. Balloon gondola diagnostics package

    NASA Astrophysics Data System (ADS)

    Cantor, K. M.

    1986-10-01

    In order to define a new gondola structural specification and to quantify the balloon termination environment, NASA developed a balloon gondola diagnostics package (GDP). This addition to the balloon flight train is comprised of a large array of electronic sensors employed to define the forces and accelerations imposed on a gondola during the termination event. These sensors include the following: a load cell, a three-axis accelerometer, two three-axis rate gyros, two magnetometers, and a two axis inclinometer. A transceiver couple allows the data to be telemetered across any in-line rotator to the gondola-mounted memory system. The GDP is commanded 'ON' just prior to parachute deployment in order to record the entire event.

  17. Diagnostic Algorithm Benchmarking

    NASA Technical Reports Server (NTRS)

    Poll, Scott

    2011-01-01

    A poster for the NASA Aviation Safety Program Annual Technical Meeting. It describes empirical benchmarking on diagnostic algorithms using data from the ADAPT Electrical Power System testbed and a diagnostic software framework.

  18. Prenatal Genetic Diagnostic Tests

    MedlinePlus

    ... Education & Events Advocacy For Patients About ACOG Prenatal Genetic Diagnostic Tests Home For Patients Search FAQs Prenatal ... Pamphlets - Spanish FAQ164, September 2016 PDF Format Prenatal Genetic Diagnostic Tests Pregnancy What is prenatal genetic testing? ...

  19. Diagnostics for ITER

    SciTech Connect

    Donne, A. J. H.; Hellermann, M. G. von; Barnsley, R.

    2008-10-22

    After an introduction into the specific challenges in the field of diagnostics for ITER (specifically high level of nuclear radiation, long pulses, high fluxes of particles to plasma facing components, need for reliability and robustness), an overview will be given of the spectroscopic diagnostics foreseen for ITER. The paper will describe both active neutral-beam based diagnostics as well as passive spectroscopic diagnostics operating in the visible, ultra-violet and x-ray spectral regions.

  20. Interventional procedures in the chest.

    PubMed

    Vollmer Torrubiano, I; Sánchez González, M

    2016-05-01

    Many thoracic conditions will require an interventional procedure for diagnosis and/or treatment. For this reason, radiologists need to know the indications and the technique for each procedure. In this article, we review the various interventional procedures that radiologists should know and the indications for each procedure. We place special emphasis on the potential differences in the diagnostic results and complications between fine-needle aspiration and biopsy. We also discuss the indications for radiofrequency ablation of lung tumors and review the concepts related to the drainage of pulmonary abscesses. We devote special attention to the management of pleural effusion, covering the indications for thoracocentesis and when to use imaging guidance, and to the protocol for pleural drainage. We also discuss the indications for percutaneous treatment of pericardial effusion and the possible complications of this treatment. Finally, we discuss the interventional management of mediastinal lesions and provide practical advice about how to approach these lesions to avoid serious complications.

  1. Intelligent diagnostics systems

    NASA Technical Reports Server (NTRS)

    Mcquiston, Barbara M.; Dehoff, Ronald L.

    1992-01-01

    Intelligent systems have been applied to today's problems and could also be applied to space operations integrity. One of these systems is the XMAN tool designed for 'troubleshooting' jet engines. XMAN is the eXpert MAiNtenance tool developed to be an expert information analysis tool which stores trending and diagnostic data on Air Force engines. XMAN operates with a 'network topology' which follows a flow chart containing engine management information reports required by the governments technical order procedures. With XMAN technology, the user is able to identify engine problems by presenting the assertions of the fault isolation logic and attempting to satisfy individual assertions by referring to the databases created by an engine monitoring system. The troubleshooting process requires interaction between the technician and the computer to acquire new evidence form auxiliary maintenance tests corroboration of analytical results to accurately diagnose equipment malfunctions. This same technology will be required for systems which are functioning in space either with an onboard crew, or with an unmanned system. The technology and lessons learned developing this technology while suggesting definite applications for its use with developing space systems are addressed.

  2. [Schizophrenia diagnostic announcement in a French psychiatric unit].

    PubMed

    Rocamora, J F; Benadhira, R; Saba, G; Stamatadis, L; Kalalaou, K; Dumortier, G; Plaze, M; Aubriot-Delmas, B; Glikman, J; Januel, D

    2005-01-01

    satisfactory information in order to gain the cooperation of the patient and its relative (10). Atkinson has classified four main types of arguments, the ethical principle to be informed, talk to explain and give sense to the symptoms, reduce the feeling of guilt perceived by the patient and his relative and enhance the collaboration between the patient and the nursing staff. According to Ferreri and Bayle studies French psychiatrists reluctance to announce schizophrenia diagnostic are the following: lack of request or of interrogations asked by the patient about their disease, diagnostic and prognosis uncertainty and irreversibility of the disease, complexity of the pathology and its origin which hinder an accessible explanation, cognitive disorders frequently observed with schizophrenic patients which may be associated with difficulties of understanding information, destabilization of the patient-nursing staff relationship and social stigmatisation risks. Other arguments like reluctance to give a "label" to the disease, too abstract diagnostic, a negative social vision and the possibility of discouragement for the relative are classically retrieved in French literature. In fact, divulgation of the term schizophrenia involves a panel of negative representations and is hindered by the confusion in the social imagination of such a term related with lost of control, quintessence of madness, dangerous behaviour possibilities, evil and incurability. Some psychiatrists do not transmit information arguing that significant obstruction of the future may be consecutive to the information. They prefer to use vague terms more socially acceptable like "nervous breakdown or depression, atypical or emotional disorder, dissociative troubles...". Information to the patient about his mental disorder is more frequent in psychiatry for affective, anxious and additive troubles than for schizophrenia. Our procedure of diagnostic announcement has been elaborated after preliminary discussion with

  3. Pneumoperitoneum, Retropneumoperitoneum, Pneumomediastinum, and Diffuse Subcutaneous Emphysema following Diagnostic Colonoscopy

    PubMed Central

    Falidas, Evangelos; Anyfantakis, Georgios; Vlachos, Konstantinos; Goudeli, Christina; Stavros, Boutzouvis; Villias, Constantinos

    2012-01-01

    Colonoscopy is a widely used diagnostic and curative procedure. Extraperitoneal perforation with pneumoretroperitoneum, pneumomediastinum and subcutaneous emphysema combined with intraperitoneal perforation is an extremely rare complication. We report a case of a 78-year-old woman presented to the emergency department with abdominal pain and diffuse abdominal, chest, neck, and facial swelling appeared after a diagnostic colonoscopy. Diagnostic and therapeutic modalities are discussed. PMID:23024878

  4. Prospective pilot trial of dexmedetomidine sedation for awake diagnostic flexible bronchoscopy.

    PubMed

    Lee, Keat; Orme, Ruari; Williams, Daryl; Segal, Reny

    2010-10-01

    Dexmedetomidine has the favorable properties of sedation, sympatholysis, analgesia, and a low risk of apnea. These properties suggest that dexmedetomidine may be useful in procedural sedation. In view of this, we conducted a pilot trial to determine the feasibility of using dexmedetomidine as a sole agent for providing sedation during awake diagnostic flexible bronchoscopy. Patients presenting for awake diagnostic flexible bronchoscopy consented to participate in a trial of dexmedetomidine sedation for the procedure. In addition to local anesthetic topicalization of the airways, dexmedetomidine was infused at 0.5 μg/kg over 10 minutes followed by an infusion of 0.2 to 0.7 μg/kg/h titrating to a Ramsay Sedation Scale score of 3. Hemodynamic parameters (heart rate, blood pressure), oxygenation status (pulse oximetry), adverse events, use of rescue sedation, and patient and proceduralist satisfaction were recorded during the trial. Five of 9 recruited patients required rescue sedation to allow the procedure to proceed. Dexmedetomidine as a sole agent at an infusion of 0.5 μg/kg over 10 minutes followed by an infusion of 0.2 to 0.7 μg/kg/h is unable to provide adequate sedation for awake diagnostic flexible bronchoscopy without the need for rescue sedation in a large proportion of patients.

  5. Oral vs. salivary diagnostics

    NASA Astrophysics Data System (ADS)

    Marques, Joana; Corby, Patricia M.; Barber, Cheryl A.; Abrams, William R.; Malamud, Daniel

    2015-05-01

    The field of "salivary diagnostics" includes studies utilizing samples obtained from a variety of sources within the oral cavity. These samples include; whole unstimulated saliva, stimulated whole saliva, duct saliva collected directly from the parotid, submandibular/sublingual glands or minor salivary glands, swabs of the buccal mucosa, tongue or tonsils, and gingival crevicular fluid. Many publications state "we collected saliva from subjects" without fully describing the process or source of the oral fluid. Factors that need to be documented in any study include the time of day of the collection, the method used to stimulate and collect the fluid, and how much fluid is being collected and for how long. The handling of the oral fluid during and post-collection is also critical and may include addition of protease or nuclease inhibitors, centrifugation, and cold or frozen storage prior to assay. In an effort to create a standard protocol for determining a biomarker's origin we carried out a pilot study collecting oral fluid from 5 different sites in the mouth and monitoring the concentrations of pro- and anti-inflammatory cytokines detected using MesoScaleDiscovery (MSD) electrochemiluminesence assays. Our data suggested that 3 of the cytokines are primarily derived from the submandibular gland, while 7 of the cytokines come from a source other than the major salivary glands such as the minor salivary glands or cells in the oral mucosae. Here we review the literature on monitoring biomarkers in oral samples and stress the need for determining the blood/saliva ratio when a quantitative determination is needed and suggest that the term oral diagnostic be used if the source of an analyte in the oral cavity is unknown.

  6. Molecular diagnostics and parasitic disease.

    PubMed

    Vasoo, Shawn; Pritt, Bobbi S

    2013-09-01

    Molecular parasitology represents an emerging field in microbiology diagnostics. Although most assays use nonstandardized, laboratory-developed methods, a few commercial systems have recently become available and are slowly being introduced into larger laboratories. In addition, a few methodologies show promise for use in field settings in which parasitic infections are endemic. This article reviews the available techniques and their applications to major parasitic diseases such as malaria, leishmaniasis, and trichomoniasis.

  7. Optimal Spectral Regions For Laser Excited Fluorescence Diagnostics For Point Of Care Application

    NASA Astrophysics Data System (ADS)

    Vaitkuviene, A.; Gėgžna, V.; Varanius, D.; Vaitkus, J.

    2011-09-01

    The tissue fluorescence gives the response of light emitting molecule signature, and characterizes the cell composition and peculiarities of metabolism. Both are useful for the biomedical diagnostics, as reported in previous our and others works. The present work demonstrates the results of application of laser excited autofluorescence for diagnostics of pathology in genital tissues, and the feasibility for the bedside at "point of care—off lab" application. A portable device using the USB spectrophotometer, micro laser (355 nm Nd:YAG, 0,5 ns pulse, repetition rate 10 kHz, output power 15 mW), three channel optical fiber and computer with diagnostic program was designed and ready for clinical trial to be used for cytology and biopsy specimen on site diagnostics, and for the endoscopy/puncture procedures. The biopsy and cytology samples, as well as intervertebral disc specimen were evaluated by pathology experts and the fluorescence spectra were investigated in the fresh and preserved specimens. The spectra were recorded in the spectral range 350-900 nm. At the initial stage the Gaussian components of spectra were found and the Mann-Whitney test was used for the groups' differentiation and the spectral regions for optimal diagnostics purpose were found. Then a formal dividing of spectra in the components or the definite width bands, where the main difference of the different group spectra was observed, was used to compare these groups. The ROC analysis based diagnostic algorithms were created for medical prognosis. The positive prognostic values and negative prediction values were determined for cervical Liquid PAP smear supernatant sediment diagnosis of being Cervicitis and Norma versus CIN2+. In a case of intervertebral disc the analysis allows to get the additional information about the disc degeneration status. All these results demonstrated an efficiency of the proposed procedure and the designed device could be tested at the point-of-care site or for

  8. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  9. Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics

    NASA Technical Reports Server (NTRS)

    Sowers, T. Shane; Kopasakis, George; Simon, Donald L.

    2008-01-01

    The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.

  10. TFTR diagnostic vacuum controller

    SciTech Connect

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller.

  11. Diagnostic Development on NSTX

    SciTech Connect

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-12-16

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted.

  12. Towards increase of diagnostic efficacy in gynecologic OCT

    NASA Astrophysics Data System (ADS)

    Kirillin, Mikhail; Panteleeva, Olga; Eliseeva, Darya; Kachalina, Olga; Sergeeva, Ekaterina; Dubasova, Lyubov; Agrba, Pavel; Mikailova, Gyular; Prudnikov, Maxim; Shakhova, Natalia

    2013-06-01

    Gynecologic applications of optical coherence tomography (OCT) are usually performed in combination with routine diagnostic procedures: laparoscopy and colposcopy. In combination with laparoscopy OCT is employed for inspection of fallopian tubes in cases of unrecognized infertility while in colposcopy it is used to identify cervix pathologies including cancer. In this paper we discuss methods for increasing diagnostic efficacy of OCT application in these procedures. For OCT-laparoscopy we demonstrate independent criteria for pathology recognition which allow to increase accuracy of diagnostics. For OCT-colposcopy we report on application of device for controlled compression allowing to sense the elasticity of the inspected cervix area and distinguish between neoplasia and inflammatory processes.

  13. BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

    SciTech Connect

    R. C. York; X. Wu; Q. Zhao

    2011-12-21

    End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

  14. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Official records or evidence compiled or created in the regular course of business, other than DoD... who has been engaged in obtaining intelligence information for the Government and that disclosure...

  15. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Official records or evidence compiled or created in the regular course of business, other than DoD... who has been engaged in obtaining intelligence information for the Government and that disclosure...

  16. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Official records or evidence compiled or created in the regular course of business, other than DoD... who has been engaged in obtaining intelligence information for the Government and that disclosure...

  17. 32 CFR Appendix A to Part 155 - Additional Procedural Guidance

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... request a hearing. It shall also explain the adverse consequences for failure to respond to the SOR within... answer is insufficient. To be entitled to a hearing, the applicant must specifically request a hearing in.... If the applicant has not requested a hearing with his or her answer to the SOR and Department...

  18. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  19. What Is Diagnostic Testing?

    MedlinePlus

    ... Primary care providers Specialists Getting covered Research Basic science research Research in people ... screening Diagnostic testing Direct-to-consumer genetic testing Newborn screening Pharmacogenomic testing ...

  20. Improving Model Performance through Process-Based Diagnostics

    NASA Astrophysics Data System (ADS)

    Clune, T.; Kuo, K.; Schmidt, G. A.; Bauer, M. P.; Oloso, A. O.

    2013-12-01

    Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models -- most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted. We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.

  1. Tuberculosis diagnostics: innovating to make an impact.

    PubMed

    Ghanashyam, Bharathi

    2011-04-01

    The 'International Symposium on TB Diagnostics: Innovating to Make an Impact' was organized by the International Centre for Genetic Engineering & Biotechnology, New Delhi, India, on December 16-17, 2010, with sponsorship support from the Bill & Melinda Gates Foundation, Foundation for Innovative New Diagnostics and AERAS Global TB Vaccine Foundation. This highly successful symposium attracted more than 300 participants from India and several other countries and covered several aspects of TB diagnostics, including recent scientific advances in TB diagnostics, progress made in expanding the TB diagnostics pipeline including a portfolio of WHO-endorsed, validated new tools and improved technologies, the successful development of newer molecular assays that have the potential to be used at the point of treatment and the growing contributions of emerging economies such as India. In addition to highlighting the positive aspects of TB diagnostics, the symposium speakers also highlighted the need to focus on worrisome aspects of TB diagnosis, including widespread abuse of inappropriate tests that can prevent the use of good diagnostics, lack of quality assurance in laboratories, lack of adequate regulation of diagnostics and how these can pose a major challenge for roll-out and implementation of new tools. The symposium ended with a very stimulating discussion on how India can become a global leader in TB innovations.

  2. Defining the diagnostic algorithm in pancreatic cancer.

    PubMed

    Horwhat, John David; Gress, Frank G

    2004-07-01

    Most patients with pancreatic cancer present with a mass on radiologic studies, however, not every pancreatic mass is cancer. Since radiological studies alone are insufficient to establish the diagnosis of a pancreatic mass and patient management depends on a definitive diagnosis; confirmatory cytology or histology is usually required. As a minimally invasive procedure, EUS and EUS FNA avoid the risk of cutaneous or peritoneal contamination that may occur with CT or US-guided investigations and is less invasive than surgical interventions. As a result, EUS FNA of pancreatic masses is becoming the standard for obtaining cytological diagnosis. This chapter presents an EUS-based diagnostic algorithm for the evaluation of pancreatic lesions and is based upon a review of the pertinent literature in the field of pancreatic endosonography that has been the most influential in helping to guide this evolving field. Realizing there is much overlap among the EUS characteristics of various pancreatic lesions, for the sake of simplicity we have structured our discussion in broad terms of solid versus cystic lesions and discuss various pancreatic lesions within this framework. The additional contributors to this round table discussion have been asked to provide a more dedicated, focused discussion of the various subcategories of pancreatic lesions in greater detail than we could hope to achieve here. We provide this final contribution to the round table as a means of bringing the discussion back to the big picture of pancreatic lesions, rather than trying to hone in on the fine details of any one subclass.

  3. TFTR diagnostic control and data acquisition system

    SciTech Connect

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  4. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  5. National Ignition Facility (NIF) operations procedures plan

    SciTech Connect

    Mantrom, D.

    1998-05-06

    The purpose of this Operations Procedures Plan is to establish a standard procedure which outlines how NIF Operations procedures will be developed (i.e , written, edited, reviewed, approved, published, revised) and accessed by the NIF Operations staff who must use procedures in order to accomplish their tasks. In addition, this Plan is designed to provide a guide to the NIF Project staff to assist them in planning and writing procedures. Also, resource and scheduling information is provided.

  6. Evaluation of the diagnostic utility of fiberoptic bronchoscopy for smear-negative pulmonary tuberculosis in routine clinical practice.

    PubMed

    Soto, Alonso; Salazar, Daniela; Acurio, Vilma; Segura, Patricia; Van der Stuyft, Patrick

    2012-01-01

    We evaluated the diagnostic yield of fiberoptic bronchoscopy for the diagnosis of smear-negative pulmonary tuberculosis in patients treated at a referral hospital in Lima, Peru. Of the 611 patients who underwent the procedure, 140 (23%) were diagnosed with tuberculosis based on the analysis of BAL samples. Being young and being male were significantly associated with positive cultures. In addition, 287 patients underwent post-bronchoscopic sputum smear testing for AFB, the results of which increased the diagnostic yield by 22% over that obtained through the analysis of BAL samples alone. We conclude that the analysis of BAL samples and post-bronchoscopic sputum samples provides a high diagnostic yield in smear-negative patients suspected of having pulmonary tuberculosis.

  7. Acute dizziness in rural practice: Proposal of a diagnostic procedure

    PubMed Central

    Eid, Ehab; Dastan, Sajed; Heckmann, Josef G.

    2015-01-01

    Acute dizziness is a frequent index symptom in the emergency department as well as in the rural practice office. Most acute dizziness, however, is not dangerous, but some types are highly dangerous. Clinical routine acute dizziness can be separated into frequent benign syndromes including benign paroxysmal positional vertigo (BPPV), vestibular neuritis, Meniθre's disease or vestibular migraine, and what is here referred to as the “white shark” of dizziness, i.e. a stroke in the posterior circulation or more rarely a tumor in the posterior fossa. A practical concept is presented to clarify most frequent acute dizziness syndromes using clinical and low budget methods. PMID:25883501

  8. Acute dizziness in rural practice: Proposal of a diagnostic procedure.

    PubMed

    Eid, Ehab; Dastan, Sajed; Heckmann, Josef G

    2015-01-01

    Acute dizziness is a frequent index symptom in the emergency department as well as in the rural practice office. Most acute dizziness, however, is not dangerous, but some types are highly dangerous. Clinical routine acute dizziness can be separated into frequent benign syndromes including benign paroxysmal positional vertigo (BPPV), vestibular neuritis, Meniθre's disease or vestibular migraine, and what is here referred to as the "white shark" of dizziness, i.e. a stroke in the posterior circulation or more rarely a tumor in the posterior fossa. A practical concept is presented to clarify most frequent acute dizziness syndromes using clinical and low budget methods.

  9. Development of a Sampling Collection Device with Diagnostic Procedures.

    PubMed

    Cheng, Jhih-Yan; Feng, Mow-Jung; Wu, Chia-Chi; Wang, Jane; Chang, Ting-Chang; Cheng, Chao-Min

    2016-08-02

    Cervicovaginal fluid plays an important role in the detection of many female genital diseases, but the lack of suitable collection devices in the market severely challenges test success rate. Appropriate clinical sampling devices for cervicovaginal fluid collection would help physicians detect diseases and disease states more rapidly, efficiently, and accurately. The objective of this study was to develop a readily usable sampling collection device that would eliminate macromolecular interference and accurately provide specimens for further studies. This study was designed to develop an effective device to collect cervicovaginal fluid from women with symptoms of endometrial lesions, women appearing in the clinic for a routine Papanicolaou smear, and/or women seeking a routine gynecologic checkup. Paper-based assay, ELISA, and qNano were used to provide accurate diagnoses. A total of 103 patients successfully used the developed device to collect cervicovaginal fluid. Some of the collected specimens were used to detect glycogen, lactate, and pH for determining pathogen infection. Other specimen samples were tested for the presence of female genital cancer by comparing interleukin 6 concentration and microvesicle concentration. We proposed a noninvasive screening test for the diagnosis of female genital diseases using a dual-material collection device. The outer, nonwoven fabric portion of this device was designed to filter macromolecules, and the inner cotton portion was designed to absorb cervicovaginal fluid.

  10. Combined procedures in laparoscopic surgery.

    PubMed

    Wadhwa, Atul; Chowbey, Pradeep K; Sharma, Anil; Khullar, Rajesh; Soni, Vandana; Baijal, Manish

    2003-12-01

    With advancements in minimal access surgery, combined laparoscopic procedures are now being performed for treating coexisting abdominal pathologies at the same surgery. In our center, we performed 145 combined surgical procedures from January 1999 to December 2002. Of the 145 procedures, 130 were combined laparoscopic/endoscopic procedures and 15 were open procedures combined with endoscopic procedures. The combination included laparoscopic cholecystectomy, various hernia repairs, and gynecological procedures like hysterectomy, salpingectomy, ovarian cystectomy, tubal ligation, urological procedures, fundoplication, splenectomy, hemicolectomy, and cystogastrostomy. In the same period, 40 patients who had undergone laparoscopic cholecystectomy and 40 patients who had undergone ventral hernia repair were randomly selected for comparison of intraoperative outcomes with a combined procedure group. All the combined surgical procedures were performed successfully. The most common procedure was laparoscopic cholecystectomy with another endoscopic procedure in 129 patients. The mean operative time was 100 minutes (range 30-280 minutes). The longest time was taken for the patient who had undergone laparoscopic splenectomy with renal transplant (280 minutes). The mean hospital stay was 3.2 days (range 1-21 days). The pain experienced in the postoperative period measured on the visual analogue scale ranged from 2 to 5 with a mean of 3.1. Of 145 patients who underwent combined surgical procedures, 5 patients developed fever in the immediate postoperative period, 7 patients had port site hematoma, 5 patients developed wound sepsis, and 10 patients had urinary retention. As long as the basic surgical principles and indications for combined procedures are adhered to, more patients with concomitant pathologies can enjoy the benefit of minimal access surgery. Minimal access surgery is feasible and appears to have several advantages in simultaneous management of two different

  11. Target Diagnostics Supports NIF's Path to Ignition

    SciTech Connect

    Shelton, R

    2011-12-07

    the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

  12. Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.

    ERIC Educational Resources Information Center

    Clancey, William J.

    This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…

  13. [Diagnostic reference levels in interventional radiology].

    PubMed

    Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I

    2013-12-01

    This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures.

  14. Magnetic Diagnostics in LDX

    NASA Astrophysics Data System (ADS)

    Karim, I.; Kesner, J.; Garnier, D.; Hansen, A.; Mauel, M.

    2003-10-01

    Magnetic diagnostics will play an essential role in understanding the equilibrium and stability of LDX plasmas. Flux loops, poloidal field coils, Hall probes, and Mirnov coils have been installed and tested for the first experimental campaign. These measurements will provide the boundary field and flux values needed as inputs to a Grad-Shafranov solver for equilibrium reconstruction. Specifically, the boundary magnetic signals constrain the location and shape of the pressure function, p(ψ). The sensors, excluding the Mirnov coils, have been installed in accordance with an optimization scheme that maximizes their sensitivity to diamagnetic currents. The Mirnov coils have been designed to detect plasma fluctuations up to MHz range to characterize MHD activity. Initial testing and calibration of the sensors have been performed in-laboratorio using a medium-sized Helmholtz pair, and the results have subsequently been compared to data obtained in-loco with a large Helmholtz pair installed on the LDX vacuum chamber. Additionally, an equilibrium reconstruction model that incorporates pressure models more appropriate for the LDX plasmas than the more common polynomial expansion has been completed.

  15. Automotive Diagnostic Technologies.

    ERIC Educational Resources Information Center

    Columbus State Community Coll., OH.

    This document contains materials developed for and about the automotive diagnostic technologies tech prep program of the South-Western City Schools in Ohio. Part 1 begins with a map of the program, which begins with an automotive/diagnostic technologies program in grades 11 and 12 that leads to entry-level employment or a 2-year automotive…

  16. Huntington Disease: Molecular Diagnostics Approach.

    PubMed

    Bastepe, Murat; Xin, Winnie

    2015-10-06

    Huntington disease (HD) is caused by expansion of a CAG trinucleotide repeat in the first exon of the Huntingtin (HTT) gene. Molecular testing of Huntington disease for diagnostic confirmation and disease prediction requires detection of the CAG repeat expansion. There are three main types of HD genetic testing: (1) diagnostic testing to confirm or rule out disease, (2) presymptomatic testing to determine whether an at-risk individual inherited the expanded allele, and (3) prenatal testing to determine whether the fetus has inherited the expanded allele. This unit includes protocols that describe the complementary use of polymerase chain reactions (PCR) and Southern blot hybridization to accurately measure the CAG trinucleotide repeat size and interpret the test results. In addition, an indirect linkage analysis that does not reveal the unwanted parental HD status in a prenatal testing will also be discussed.

  17. A Review of the Diagnostic Methods Reported in the Journal of Autism and Developmental Disorders.

    ERIC Educational Resources Information Center

    Waller, Stacey A.; Armstrong, Kevin J.; McGrath, Ann M.; Sullivan, Cristin L.

    1999-01-01

    This review summarizes subject selection and diagnostic procedures documented in 142 empirical articles published between 1993 and 1997. Although most researchers reported use of standard diagnostic criteria in classifying subjects, numerous studies did not report diagnostic methods and there was often a lack of specification of inclusion and…

  18. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  19. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  20. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  1. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within...

  2. Diagnostics of Nanodusty Plasma

    NASA Astrophysics Data System (ADS)

    Greiner, Franko; Groth, Sebastian; Tadsen, Bejamin; Piel, Alexander

    2015-11-01

    The diagnostic of nanodusty plasmas, i.e. plasmas including nano-sized dust particles, is a challenging task. For both, the diagnostic of the nanodusty plasma itself, and the in-situ diagnostic of the nanoparticles, no standard diagnostic exist. Nanodust particle size and density can be estimated using light scattering techniques, namely kinetic Mie ellipsometry and extinction measurements. The charge of the nanoparticles can be estimated from the analysis of dust density waves (DDW). Parameters like the electron density, which give information about the plasma itself, may be deduced from the DDW analysis. We present detailed investigations on nanodust in a reactive Argon-Acetylene plasma created in an rf-driven parallel plate reactor at low pressure using the above mentioned portfolio of diagnostic. Funded by DFG under contract SFB TR-24/A2.

  3. Rayleigh Scattering Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard (Compiler)

    1996-01-01

    The Rayleigh Scattering Diagnostics Workshop was held July 25-26, 1995 at the NASA Lewis Research Center in Cleveland, Ohio. The purpose of the workshop was to foster timely exchange of information and expertise acquired by researchers and users of laser based Rayleigh scattering diagnostics for aerospace flow facilities and other applications. This Conference Publication includes the 12 technical presentations and transcriptions of the two panel discussions. The first panel was made up of 'users' of optical diagnostics, mainly in aerospace test facilities, and its purpose was to assess areas of potential applications of Rayleigh scattering diagnostics. The second panel was made up of active researchers in Rayleigh scattering diagnostics, and its purpose was to discuss the direction of future work.

  4. System diagnostic builder

    NASA Technical Reports Server (NTRS)

    Nieten, Joseph L.; Burke, Roger

    1992-01-01

    The System Diagnostic Builder (SDB) is an automated software verification and validation tool using state-of-the-art Artificial Intelligence (AI) technologies. The SDB is used extensively by project BURKE at NASA-JSC as one component of a software re-engineering toolkit. The SDB is applicable to any government or commercial organization which performs verification and validation tasks. The SDB has an X-window interface, which allows the user to 'train' a set of rules for use in a rule-based evaluator. The interface has a window that allows the user to plot up to five data parameters (attributes) at a time. Using these plots and a mouse, the user can identify and classify a particular behavior of the subject software. Once the user has identified the general behavior patterns of the software, he can train a set of rules to represent his knowledge of that behavior. The training process builds rules and fuzzy sets to use in the evaluator. The fuzzy sets classify those data points not clearly identified as a particular classification. Once an initial set of rules is trained, each additional data set given to the SDB will be used by a machine learning mechanism to refine the rules and fuzzy sets. This is a passive process and, therefore, it does not require any additional operator time. The evaluation component of the SDB can be used to validate a single software system using some number of different data sets, such as a simulator. Moreover, it can be used to validate software systems which have been re-engineered from one language and design methodology to a totally new implementation.

  5. Efficacy and Safety of Pancreatobiliary Endoscopic Procedures during Pregnancy

    PubMed Central

    Lee, Jae Joon; Lee, Sung Koo; Kim, Sang Hyung; Kim, Ga Hee; Park, Do Hyun; Lee, Sangsoo; Seo, Dongwan; Kim, Myung-Hwan

    2015-01-01

    Background/Aims Endoscopic therapy with endoscopic retrograde cholangiopancreatography (ERCP) has been suggested as an effective diagnostic and therapeutic tool for biliary and pancreatic disorders during pregnancy. In this report, we describe our experiences with pancreatobiliary endoscopic procedures during pregnancy. Methods We reviewed ERCP and endoscopic ultrasonography (EUS) procedures that were performed at a single tertiary care referral center between January 2002 and October 2013. Medical records were reviewed for the procedure indication, the duration of fluoroscopy, postprocedure complications, etc. Pregnancy outcomes and fetal complications were identified by chart review and phone calls to patients. Results A total of 10 ER-CPs and five EUSs were performed in 13 pregnant patients: four of whom underwent the procedure in the first trimester, eight in the second trimester, and one in the third trimester. Indications for endoscopic therapy included gallstone pancreatitis, obstructive jaundice with common bile duct (CBD) stone, asymptomatic CBD stone, pancreatic cyst, choledochal cyst, and acute cholecystitis. Only one patient had a complication, which was postprocedural hyperamylasemia. Two patients underwent an artificial abortion, one according to her own decision and the other due to an adverse drug reaction. Conclusions ERCP seems to be effective and safe for pregnant women. Additionally, EUS can be an alternative to ERCP during pregnancy. PMID:26087783

  6. Diagnostics on Z (invited)

    NASA Astrophysics Data System (ADS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.; Hurst, M.; Jobe, D.; Torres, J.; Seaman, J.; Struve, K.; Lazier, S.; Gilliland, T.; Ruggles, L. A.; Simpson, W. A.; Adams, R.; Seaman, J. A.; Wenger, D.; Nielsen, D.; Riley, P.; French, R.; Stygar, B.; Wagoner, T.; Sanford, T. W. L.; Mock, R.; Asay, J.; Hall, C.; Knudson, M.; Armijo, J.; McKenney, J.; Hawn, R.; Schroen-Carey, D.; Hebron, D.; Cutler, T.; Dropinski, S.; Deeney, C.; LePell, P. D.; Coverdale, C. A.; Douglas, M.; Cuneo, M.; Hanson, D.; Bailey, J. E.; Lake, P.; Carlson, A.; Wakefield, C.; Mills, J.; Slopek, J.; Dinwoodie, T.; Idzorek, G.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12° above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them.

  7. [Role of cytology in hematopathological diagnostics].

    PubMed

    Bode, B; Tinguely, M

    2012-07-01

    The role of cytology has so far been underrecognized in the diagnostic process of hematopathological questions. This article presents an algorithm which allows a stepwise work-up of cytology specimens obtained by minimally invasive ultrasound-guided fine needle aspiration in patients with unexplained lymph node swelling. Moreover, it is shown how the selective separation of cytology specimens allows the application of immunophenotypic analysis including flow cytometry and immunohistochemistry as well as molecular analyses, such as fluorescence in situ hybridization (FISH) and polymerase chain reaction (PCR) strategies. With the integrative procedure presented, cytology offers an excellent cost-effective tool for the diagnostic approach of patients with suspected hematopathological malignancies allowing a high diagnostic accuracy, ideal for initial diagnosis or follow-up.

  8. Cryptosporidiosis: multiattribute evaluation of six diagnostic methods.

    PubMed Central

    MacPherson, D W; McQueen, R

    1993-01-01

    Six diagnostic methods (Giemsa staining, Ziehl-Neelsen staining, auramine-rhodamine staining, Sheather's sugar flotation, an indirect immunofluorescence procedure, and a modified concentration-sugar flotation method) for the detection of Cryptosporidium spp. in stool specimens were compared on the following attributes: diagnostic yield, cost to perform each test, ease of handling, and ability to process large numbers of specimens for screening purposes by batching. A rank ordering from least desirable to most desirable was then established for each method by using the study attributes. The process of decision analysis with respect to the laboratory diagnosis of cryptosporidiosis is discussed through the application of multiattribute utility theory to the rank ordering of the study criteria. Within a specific health care setting, a diagnostic facility will be able to calculate its own utility scores for our study attributes. Multiattribute evaluation and analysis are potentially powerful tools in the allocation of resources in the laboratory. PMID:8432802

  9. Video integrated measurement system. [Diagnostic display devices

    SciTech Connect

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  10. Melioidosis Diagnostic Workshop, 20131

    PubMed Central

    AuCoin, David; Baccam, Prasith; Baggett, Henry C.; Baird, Rob; Bhengsri, Saithip; Blaney, David D.; Brett, Paul J.; Brooks, Timothy J.G.; Brown, Katherine A.; Chantratita, Narisara; Cheng, Allen C.; Dance, David A.B.; Decuypere, Saskia; Defenbaugh, Dawn; Gee, Jay E.; Houghton, Raymond; Jorakate, Possawat; Lertmemongkolchai, Ganjana; Limmathurotsakul, Direk; Merlin, Toby L.; Mukhopadhyay, Chiranjay; Norton, Robert; Peacock, Sharon J.; Rolim, Dionne B.; Simpson, Andrew J.; Steinmetz, Ivo; Stoddard, Robyn A.; Stokes, Martha M.; Sue, David; Tuanyok, Apichai; Whistler, Toni; Wuthiekanun, Vanaporn; Walke, Henry T.

    2015-01-01

    Melioidosis is a severe disease that can be difficult to diagnose because of its diverse clinical manifestations and a lack of adequate diagnostic capabilities for suspected cases. There is broad interest in improving detection and diagnosis of this disease not only in melioidosis-endemic regions but also outside these regions because melioidosis may be underreported and poses a potential bioterrorism challenge for public health authorities. Therefore, a workshop of academic, government, and private sector personnel from around the world was convened to discuss the current state of melioidosis diagnostics, diagnostic needs, and future directions. PMID:25626057

  11. Pediatric diagnostic imaging

    SciTech Connect

    Gyll, C.; Blake, N.S.

    1986-01-01

    This book treats the practical problems of pediatric radiography and radiological procedures. Written jointly by a radiographer and a radiologist, it covers pediatric positioning and procedures. An extended chapter covers neonatal radiography and radiology.

  12. [Validation of a diagnostic scoring system (Ohmann score) in acute appendicitis].

    PubMed

    Zielke, A; Sitter, H; Rampp, T A; Schäfer, E; Hasse, C; Lorenz, W; Rothmund, M

    1999-07-01

    A diagnostic scoring system, recently published by Ohmann et al. in this journal, was validated by analyzing the clinicopathological data of a consecutive series of 2,359 patients, admitted for suspicion of acute appendicitis. The results of the scoring system were compared to the results of clinical evaluation by junior (provisional) and senior surgeons (final clinical diagnosis). To assess the diagnostic ability of the score, the accuracy and positive predictive value were defined as the major diagnostic performance parameters; the rate of theoretical negative laparotomies and that of diagnostic errors served as the major procedural performance parameters. Of 2,359 patients admitted for suspected acute appendicitis, 662 were proven to have acute appendicitis by histology, for a prevalence of 28%. The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the provisional clinical diagnosis were 0.50, 0.94, 0.77, 0.83, and 0.82; 0.93, for the score 0.63, 0.93, 0.77, 0.86 and 0.84, and for the final clinical diagnosis 0.90, 0.94, 0.85, 0.96, and 0.93, respectively. Of the main diagnostic performance parameter, the accuracy of the score was significantly better than that of provisional clinical diagnosis (P < 0.05, chi 2 test). The score yielded a rate of negative appendecomies and laparotomies of 14.3 and 12.3%. With respect to the rate of overlooked cases of acute apendicitis, the score demonstrated a superior performance, with only 6 cases missed (0.9%). However, the number of patients with acute appendicitis, including those with perforated disease, who were not identified by the score, was almost four times that of the final clinical diagnosis (245 vs 63). With regard to the main procedural performance parameter, the score resulted in a significantly smaller number of diagnostic errors than the provisional clinical investigator (P < 0.05, chi 2 test). The results of this study indicate that the diagnostic scoring

  13. Sonography: the leading diagnostic tool for diseases of the salivary glands.

    PubMed

    Zengel, P; Schrötzlmair, F; Reichel, C; Paprottka, P; Clevert, D A

    2013-06-01

    Ultrasound examination is the imaging procedure with the best predictive diagnostic capability for the salivary glands. Due to the salivary glands' relatively superficial anatomical location, clear boundary from surrounding tissue and comparatively typical echogenicity, therefore sonography is ideal for diagnosis. In addition, the technical advances in recent years, including higher resolution, color Doppler sonography, contrast-enhanced ultrasound, elastography, and tissue harmonic have lead to an improvement in diagnostic accuracy of sonography further resulting in an expansion of the range of indications. Sonography allows detection of obstructive salivary gland diseases such as stenosis or sialolithiasis, as well as sialadenosis such as Sjögren syndrome. Ultrasound examination alone is sufficient to diagnose benign tumors. However, in the case of malignant tumors, computer tomography or MRI may be also required, especially to determine the question of infiltration of the skull base.

  14. Invasive diagnostic techniques in idiopathic interstitial pneumonias.

    PubMed

    Poletti, Venerino; Ravaglia, Claudia; Gurioli, Carlo; Piciucchi, Sara; Dubini, Alessandra; Cavazza, Alberto; Chilosi, Marco; Rossi, Andrea; Tomassetti, Sara

    2016-01-01

    Fibrosing interstitial lung diseases (f-ILDs) represent a heterogeneous group of disorders in which the aetiology may be identified or, not infrequently, remain unknown. Establishing a correct diagnosis of a distinct f-ILD requires a multidisciplinary approach, integrating clinical profile, physiological and laboratory data, radiological appearance and, when appropriate, histological findings. Surgical lung biopsy is still considered the most important diagnostic tool as it is able to provide lung samples large enough for identification of complex patterns such as usual interstitial pneumonitis (UIP) and nonspecific interstitial pneumonitis. However, this procedure is accompanied by significant morbidity and mortality. Bronchoalveolar lavage is still a popular diagnostic tool allowing identification of alternative diagnoses in patients with suspected idiopathic pulmonary fibrosis (IPF) when an increase in lymphocytes is detected. Conventional transbronchial lung biopsy has a very low sensitivity in detecting the UIP pattern and its role in this clinical-radiological context is marginal. The introduction of less invasive methods such as transbronchial cryobiopsy show great promise to clinical practice as they can be used to obtain samples large enough to morphologically support a diagnosis of IPF or other idiopathic interstitial pneumonias, along with fewer complications. Recent advances in the field suggest that less invasive methods of lung sampling, without significant side effects, in combination with other diagnostic methods could replace the need for surgical lung biopsy in the future. Indeed, these new multidisciplinary procedures may become the main diagnostic work-up method for patients with suspected idiopathic interstitial pneumonia.

  15. Malaria Diagnostics in Clinical Trials

    PubMed Central

    Murphy, Sean C.; Shott, Joseph P.; Parikh, Sunil; Etter, Paige; Prescott, William R.; Stewart, V. Ann

    2013-01-01

    Malaria diagnostics are widely used in epidemiologic studies to investigate natural history of disease and in drug and vaccine clinical trials to exclude participants or evaluate efficacy. The Malaria Laboratory Network (MLN), managed by the Office of HIV/AIDS Network Coordination, is an international working group with mutual interests in malaria disease and diagnosis and in human immunodeficiency virus/acquired immunodeficiency syndrome clinical trials. The MLN considered and studied the wide array of available malaria diagnostic tests for their suitability for screening trial participants and/or obtaining study endpoints for malaria clinical trials, including studies of HIV/malaria co-infection and other malaria natural history studies. The MLN provides recommendations on microscopy, rapid diagnostic tests, serologic tests, and molecular assays to guide selection of the most appropriate test(s) for specific research objectives. In addition, this report provides recommendations regarding quality management to ensure reproducibility across sites in clinical trials. Performance evaluation, quality control, and external quality assessment are critical processes that must be implemented in all clinical trials using malaria tests. PMID:24062484

  16. DNA Microarray-Based Diagnostics.

    PubMed

    Marzancola, Mahsa Gharibi; Sedighi, Abootaleb; Li, Paul C H

    2016-01-01

    The DNA microarray technology is currently a useful biomedical tool which has been developed for a variety of diagnostic applications. However, the development pathway has not been smooth and the technology has faced some challenges. The reliability of the microarray data and also the clinical utility of the results in the early days were criticized. These criticisms added to the severe competition from other techniques, such as next-generation sequencing (NGS), impacting the growth of microarray-based tests in the molecular diagnostic market.Thanks to the advances in the underlying technologies as well as the tremendous effort offered by the research community and commercial vendors, these challenges have mostly been addressed. Nowadays, the microarray platform has achieved sufficient standardization and method validation as well as efficient probe printing, liquid handling and signal visualization. Integration of various steps of the microarray assay into a harmonized and miniaturized handheld lab-on-a-chip (LOC) device has been a goal for the microarray community. In this respect, notable progress has been achieved in coupling the DNA microarray with the liquid manipulation microsystem as well as the supporting subsystem that will generate the stand-alone LOC device.In this chapter, we discuss the major challenges that microarray technology has faced in its almost two decades of development and also describe the solutions to overcome the challenges. In addition, we review the advancements of the technology, especially the progress toward developing the LOC devices for DNA diagnostic applications.

  17. Sequencing Needs for Viral Diagnostics

    SciTech Connect

    Gardner, S N; Lam, M; Mulakken, N J; Torres, C L; Smith, J R; Slezak, T

    2004-01-26

    We built a system to guide decisions regarding the amount of genomic sequencing required to develop diagnostic DNA signatures, which are short sequences that are sufficient to uniquely identify a viral species. We used our existing DNA diagnostic signature prediction pipeline, which selects regions of a target species genome that are conserved among strains of the target (for reliability, to prevent false negatives) and unique relative to other species (for specificity, to avoid false positives). We performed simulations, based on existing sequence data, to assess the number of genome sequences of a target species and of close phylogenetic relatives (''near neighbors'') that are required to predict diagnostic signature regions that are conserved among strains of the target species and unique relative to other bacterial and viral species. For DNA viruses such as variola (smallpox), three target genomes provide sufficient guidance for selecting species-wide signatures. Three near neighbor genomes are critical for species specificity. In contrast, most RNA viruses require four target genomes and no near neighbor genomes, since lack of conservation among strains is more limiting than uniqueness. SARS and Ebola Zaire are exceptional, as additional target genomes currently do not improve predictions, but near neighbor sequences are urgently needed. Our results also indicate that double stranded DNA viruses are more conserved among strains than are RNA viruses, since in most cases there was at least one conserved signature candidate for the DNA viruses and zero conserved signature candidates for the RNA viruses.

  18. Multilayer Thin Film Sensors for Damage Diagnostics

    NASA Astrophysics Data System (ADS)

    Protasov, A. G.; Gordienko, Y. G.; Zasimchuk, E. E.

    2006-03-01

    The new innovative approach to damage diagnostics within the production and maintenance/servicing procedures in industry is proposed. It is based on the real-time multiscale monitoring of the smart-designed multilayer thin film sensors of fatigue damage with the standard electrical input/output interfaces which can be connected to the embedded and on-board computers. The multilayer thin film sensors supply information about the actual unpredictable deformation damage, actual fatigue life, strain localization places, damage spreading, etc.

  19. Evolution of diagnostic criteria for multiple sclerosis.

    PubMed

    Przybek, Joanna; Gniatkowska, Inga; Mirowska-Guzel, Dagmara; Członkowska, Anna

    2015-01-01

    Multiple sclerosis is a chronic demyelinating disease of the central nervous system that occurs primarily in young adults. There is no single diagnostic test to recognize the disease. The diagnostic criteria, based on clinical examination and laboratory tests, have changed considerably over time. The first guidelines involved only the results of the patient's neurological examination. The diagnostic criteria developed by Poser in 1983 were based largely on the results of additional tests, including visual evoked potentials and analysis of cerebrospinal fluid. The McDonald criteria, developed in 2001 and updated in 2005 and 2010, reflected the diagnostic breakthrough caused by widespread use of magnetic resonance imaging (MRI). Currently, the diagnosis depends largely on the results of the MRI examination. An early diagnosis is particularly important for starting disease-modifying treatments.

  20. DEVELOPMENT OF SIGNAL PROCESSING TOOLS AND HARDWARE FOR PIEZOELECTRIC SENSOR DIAGNOSTIC PROCESSES

    SciTech Connect

    OVERLY, TIMOTHY G.; PARK, GYUHAE; FARRAR, CHARLES R.

    2007-02-09

    This paper presents a piezoelectric sensor diagnostic and validation procedure that performs in -situ monitoring of the operational status of piezoelectric (PZT) sensor/actuator arrays used in structural health monitoring (SHM) applications. The validation of the proper function of a sensor/actuator array during operation, is a critical component to a complete and robust SHM system, especially with the large number of active sensors typically involved. The method of this technique used to obtain the health of the PZT transducers is to track their capacitive value, this value manifests in the imaginary part of measured electrical admittance. Degradation of the mechanical/electric properties of a PZT sensor/actuator as well as bonding defects between a PZT patch and a host structure can be identified with the proposed procedure. However, it was found that temperature variations and changes in sensor boundary conditions manifest themselves in similar ways in the measured electrical admittances. Therefore, they examined the effects of temperature variation and sensor boundary conditions on the sensor diagnostic process. The objective of this study is to quantify and classify several key characteristics of temperature change and to develop efficient signal processing techniques to account for those variations in the sensor diagnostis process. In addition, they developed hardware capable of making the necessary measurements to perform the sensor diagnostics and to make impedance-based SHM measurements. The paper concludes with experimental results to demonstrate the effectiveness of the proposed technique.

  1. Radiation Safety in Nuclear Medicine Procedures.

    PubMed

    Cho, Sang-Geon; Kim, Jahae; Song, Ho-Chun

    2017-03-01

    Since the nuclear disaster at the Fukushima Daiichi Nuclear Power Plant in 2011, radiation safety has become an important issue in nuclear medicine. Many structured guidelines or recommendations of various academic societies or international campaigns demonstrate important issues of radiation safety in nuclear medicine procedures. There are ongoing efforts to fulfill the basic principles of radiation protection in daily nuclear medicine practice. This article reviews important principles of radiation protection in nuclear medicine procedures. Useful references, important issues, future perspectives of the optimization of nuclear medicine procedures, and diagnostic reference level are also discussed.

  2. Radioactive diagnostic agent

    SciTech Connect

    Shigematsu, A.; Aihara, M.; Matsuda, M.; Suzuki, A.; Tsuya, A.

    1984-02-07

    A radioactive diagnostic agent for renal cortex, adrenal cortex, myocardium, brain stem, spinal nerve, etc., which comprises as an essential component monoiodoacetic acid wherein the iodine atom is radioactive.

  3. Fermilab recycler diagnostics

    SciTech Connect

    Martin Hu

    2001-07-24

    The Fermilab Recycler Ring is a permanent magnet storage ring for the storage and cooling of antiprotons. The following note describes the diagnostic tools currently available for commissioning, as well as the improvements and upgrades planned for the near future.

  4. Principles of plasma diagnostics

    NASA Astrophysics Data System (ADS)

    Hutchinson, Ian H.

    The physical principles, techniques, and instrumentation of plasma diagnostics are examined in an introduction and reference work for students and practicing scientists. Topics addressed include basic plasma properties, magnetic diagnostics, plasma particle flux, and refractive-index measurements. Consideration is given to EM emission by free and bound electrons, the scattering of EM radiation, and ion processes. Diagrams, drawings, graphs, sample problems, and a glossary of symbols are provided.

  5. Laser fluorescence diagnostics

    NASA Astrophysics Data System (ADS)

    Kozlov, V. K.; Krasilnikov, D. M.; Turkin, V. V.

    1995-01-01

    This paper descsribes the development of an apparatus, method, and practical recommendation on using fluorescence diagnostics in alimentary-intestinal tract surgery and analyses of blood serum and plasma for investigating influence of various drug preparations on a human organism. The report of the firm Israel Aircraft Industries on the high efficiency of using fluorescent analysis in early diagnostics of rectum, lung, and breast cancer has stimulated our publication.

  6. [Flat-detector computed tomography in diagnostic and interventional neuroradiology].

    PubMed

    Struffert, T; Doerfler, A

    2009-09-01

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with film-screen and phosphor luminescence, radiography flat detector technology is now widely accepted for neuroangiographic imaging. Especially flat-detector computed tomography (FD-CT), which uses rotational C-arm mounted flat-panel detector technology, is capable of volumetric imaging with a high spatial resolution. As "angiographic CT" FD-CT may be helpful in many diagnostic and neurointerventional procedures, e.g. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolization of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angiography suite FD-CT allows rapid visualization of periprocedural hemorrhaging and may thus improve rapid complication management without the need of patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single modality. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. Imaging of the temporal bone may also develop into an important field of FD-CT. This paper briefly reviews the technical principles of FD technology and the potential applications in diagnostic and interventional neuroradiology.

  7. Loop-mediated isothermal amplification with the Procedure for Ultra Rapid Extraction kit for the diagnosis of pneumocystis pneumonia.

    PubMed

    Kawano, Shuichi; Maeda, Takuya; Suzuki, Takefumi; Abe, Tatsuhiro; Mikita, Kei; Hamakawa, Yusuke; Ono, Takeshi; Sonehara, Wataru; Miyahira, Yasushi; Kawana, Akihiko

    2015-03-01

    Loop-mediated isothermal amplification (LAMP) is an innovative molecular technique requiring only a heating device and isothermal conditions to amplify a specific target gene. The results of current microscopic diagnostic tools for pneumocystis pneumonia are not sufficiently consistent for detecting infection with a low-density of Pneumocystis jirovecii. Although polymerase chain reaction (PCR) is highly sensitive, it is not suitable for resource-limited facilities. LAMP is a potential diagnostic replacement for PCR in such settings but a critical disadvantage of DNA extraction was still remained. Therefore, we employed the Procedure for Ultra Rapid Extraction (PURE) kit, which uses a porous material, to isolate the DNA from clinical samples in a simple way in combination with previously reported LAMP procedure for diagnosing PCP. The detection limit of the PURE-LAMP method applied to artificial bronchoalveolar lavage fluid samples was 100 copies/tube, even with the use of massive blood-contaminated solutions. In addition, we concluded the diagnostic procedure within 1 h without the need for additional equipment. PURE-LAMP coupled with suitable primers for specific pathogens has good potential for diagnosing various infectious diseases.

  8. Needle track seeding following percutaneous procedures for hepatocellular carcinoma

    PubMed Central

    Cabibbo, Giuseppe; Craxì, Antonio

    2009-01-01

    Neoplastic seeding may arise after diagnostic or therapeutic percutaneous procedures for hepatocellular carcinoma. The true incidence of seeding with hepatocellular carcinoma is difficult to assess precisely, but a significant risk of seeding exists and is greater when performing diagnostic biopsy as compared to therapeutic percutaneous procedures [radiofrequency ablation, radiofrequency ablation (RFA); percutaneous ethanol injection, Percutaneous ethanol injection (PEI)]. Whenever liver transplantation is feasible, diagnostic needle biopsies should be avoided, but RFA and PEI are often needed as “bridge” treatments. The role of adjuvant treatments in reducing the incidence of seeding following RFA or PEI requires further evaluation. PMID:21160966

  9. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    SciTech Connect

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  10. Advanced smile diagnostics using CAD/CAM mock-ups.

    PubMed

    Sancho-Puchades, Manuel; Fehmer, Vincent; Hämmerle, Christoph; Sailer, Irena

    2015-01-01

    Diagnostics are essential for predictable restorative dentistry. Both patient and clinician must agree on a treatment goal before the final restorations are delivered to avoid future disappointments. However, fully understanding the patient's desires is difficult. A useful tool to overcome this problem is the diagnostic wax-up and mock-up. A potential treatment outcome is modeled in wax prior to treatment and transferred into the patient's mouth using silicon indexes and autopolymerizing resin to obtain the patient's approval. Yet, this time-consuming procedure only produces a single version of the possible treatment outcome, which can be unsatisfactory for both the patient and the restorative team. Contemporary digital technologies may provide advantageous features to aid in this diagnostic treatment step. This article reviews opportunities digital technologies offer in the diagnostic phase, and presents clinical cases to illustrate the procedures.

  11. The Evolution of Diagnostic and Interventional Ultrasound in Sports Medicine.

    PubMed

    Finnoff, Jonathan T

    2016-03-01

    Diagnostic and interventional ultrasound is a rapidly evolving field in sports medicine. The use of ultrasound has increased exponentially during the past decades. This imaging modality is appealing to sports medicine physicians because of its broad diagnostic and interventional capabilities. In sports medicine, the indications for diagnostic ultrasound extend well beyond the musculoskeletal realm to include other conditions such as ocular trauma, thoracoabdominal trauma, and cardiac morphology. Thus, the term "sports ultrasound" has been adopted as a more accurate representation of the broad and unique applications of ultrasound in this specialty. Ultrasound-guided procedures also have evolved from the commonly performed joint and tendon sheath injections to include ultrasound-guided surgical procedures. This article will discuss the evolution of diagnostic and interventional ultrasound in sports medicine using a case-based approach to highlight its many new applications.

  12. Quality control for diagnostic oral microbiology laboratories in European countries.

    PubMed

    Rautemaa-Richardson, Riina; der Reijden Wa, Wil A Van; Dahlen, Gunnar; Smith, Andrew J

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB) Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135) number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections.

  13. Diagnostic validity of basic symptoms.

    PubMed

    Klosterkötter, J; Ebel, H; Schultze-Lutter, F; Steinmeyer, E M

    1996-01-01

    Although the Bonn Scale for the Assessment of Basic Symptoms (BSABS) [13] has come into use in several European countries, its diagnostic validity has not yet been sufficiently examined. That is why we have assessed BSABS items on a sample of 243 consecutive admissions to the Department of Psychiatry at the RWTH University, Aachen, and 79 psychologically healthy persons. Then, a cluster analysis was calculated to identify the empirical item-grouping. Five well-interpretable BSABS subsyndromes were found. In addition, uni- and multivariate analyses were computed to evaluate the diagnostic validity of these subsyndromes. We were able to show that every BSABS subsyndrome separates at least schizophrenic, organic mental and affective disorders from personality, neurotic and substance-induced disorders, as well as from psychological health. Furthermore, the subsyndrome "information processing disturbances" differentiates between schizophrenic and organic mental disorders, on the one hand, and affective disorders, on the other, and additionally, the subsyndrome "interpersonal irritation" between schizophrenics and all other persons examined.

  14. [Diagnostic imaging of splenic disease].

    PubMed

    Völk, M; Strotzer, M

    2006-03-01

    Primary diseases of the spleen are relatively rare. More frequently, the spleen is involved secondarily in hematological, oncological, infectious, immunological, vascular, and other systemic diseases. The spleen is the most commonly injured organ in blunt abdominal trauma. Anatomical and physiological basics are explained, in addition to embryological facts with resulting abnormalities, such as accessory and "wandering" spleen, and polysplenia. The most frequent primary and secondary diseases of the spleen, including rare diagnoses, are presented and illustrated. Hemangioma represents the most common primary benign tumor, and lymphoma the most common primary malignant tumor of the spleen. Diagnostic imaging does not a allow safe differentiation between Hodgkin's and non-Hodgkin's lymphoma. One section deals with the clinical value and diagnostic workup of incidentally detected lesions. Simple cysts and calcifications need neither clarification nor a follow-up examination. Atypical cysts should be controlled within 3-6 months. Additional clarification using CT or MRT should be reserved for cases with a strong suspicion of clinically relevant primary or secondary splenic disease.

  15. Standard procedures for adults in accredited sleep medicine centres in Europe.

    PubMed

    Fischer, Jürgen; Dogas, Zoran; Bassetti, Claudio L; Berg, Søren; Grote, Ludger; Jennum, Poul; Levy, Patrick; Mihaicuta, Stefan; Nobili, Lino; Riemann, Dieter; Puertas Cuesta, F Javier; Raschke, Friedhart; Skene, Debra J; Stanley, Neil; Pevernagie, Dirk

    2012-08-01

    The present paper describes standardized procedures within clinical sleep medicine. As such, it is a continuation of the previously published European guidelines for the accreditation of sleep medicine centres and European guidelines for the certification of professionals in sleep medicine, aimed at creating standards of practice in European sleep medicine. It is also part of a broader action plan of the European Sleep Research Society, including the process of accreditation of sleep medicine centres and certification of sleep medicine experts, as well as publishing the Catalogue of Knowledge and Skills for sleep medicine experts (physicians, non-medical health care providers, nurses and technologists), which will be a basis for the development of relevant educational curricula. In the current paper, the standard operational procedures sleep medicine centres regarding the diagnostic and therapeutic management of patients evaluated at sleep medicine centres, accredited according to the European Guidelines, are based primarily on prevailing evidence-based medicine principles. In addition, parts of the standard operational procedures are based on a formalized consensus procedure applied by a group of Sleep Medicine Experts from the European National Sleep Societies. The final recommendations for standard operational procedures are categorized either as 'standard practice', 'procedure that could be useful', 'procedure that is not useful' or 'procedure with insufficient information available'. Standard operational procedures described here include both subjective and objective testing, as well as recommendations for follow-up visits and for ensuring patients' safety in sleep medicine. The overall goal of the actual standard operational procedures is to further develop excellence in the practice and quality assurance of sleep medicine in Europe.

  16. Development of companion diagnostics

    SciTech Connect

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; Pryma, Daniel A.

    2015-12-12

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. Lastly, the review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.

  17. Development of companion diagnostics

    DOE PAGES

    Mankoff, David A.; Edmonds, Christine E.; Farwell, Michael D.; ...

    2015-12-12

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient’s cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods asmore » companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has “hit” the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2–targeted therapy. Lastly, the review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.« less

  18. Development of Companion Diagnostics.

    PubMed

    Mankoff, David A; Edmonds, Christine E; Farwell, Michael D; Pryma, Daniel A

    2016-01-01

    The goal of individualized and targeted treatment and precision medicine requires the assessment of potential therapeutic targets to direct treatment selection. The biomarkers used to direct precision medicine, often termed companion diagnostics, for highly targeted drugs have thus far been almost entirely based on in vitro assay of biopsy material. Molecular imaging companion diagnostics offer a number of features complementary to those from in vitro assay, including the ability to measure the heterogeneity of each patient's cancer across the entire disease burden and to measure early changes in response to treatment. We discuss the use of molecular imaging methods as companion diagnostics for cancer therapy with the goal of predicting response to targeted therapy and measuring early (pharmacodynamic) response as an indication of whether the treatment has "hit" the target. We also discuss considerations for probe development for molecular imaging companion diagnostics, including both small-molecule probes and larger molecules such as labeled antibodies and related constructs. We then describe two examples where both predictive and pharmacodynamic molecular imaging markers have been tested in humans: endocrine therapy for breast cancer and human epidermal growth factor receptor type 2-targeted therapy. The review closes with a summary of the items needed to move molecular imaging companion diagnostics from early studies into multicenter trials and into the clinic.

  19. MJO Simulation Diagnostics

    SciTech Connect

    Waliser, D; Sperber, K; Hendon, H; Kim, D; Maloney, E; Wheeler, M; Weickmann, K; Zhang, C; Donner, L; Gottschalck, J; Higgins, W; Kang, I; Legler, D; Moncrieff, M; Schubert, S; Stern, W; Vitart, F; Wang, B; Wang, W; Woolnough, S

    2008-06-02

    The Madden-Julian Oscillation (MJO) interacts with, and influences, a wide range of weather and climate phenomena (e.g., monsoons, ENSO, tropical storms, mid-latitude weather), and represents an important, and as yet unexploited, source of predictability at the subseasonal time scale. Despite the important role of the MJO in our climate and weather systems, current global circulation models (GCMs) exhibit considerable shortcomings in representing this phenomenon. These shortcomings have been documented in a number of multi-model comparison studies over the last decade. However, diagnosis of model performance has been challenging, and model progress has been difficult to track, due to the lack of a coherent and standardized set of MJO diagnostics. One of the chief objectives of the US CLIVAR MJO Working Group is the development of observation-based diagnostics for objectively evaluating global model simulations of the MJO in a consistent framework. Motivation for this activity is reviewed, and the intent and justification for a set of diagnostics is provided, along with specification for their calculation, and illustrations of their application. The diagnostics range from relatively simple analyses of variance and correlation, to more sophisticated space-time spectral and empirical orthogonal function analyses. These diagnostic techniques are used to detect MJO signals, to construct composite life-cycles, to identify associations of MJO activity with the mean state, and to describe interannual variability of the MJO.

  20. Recent improvements of the JET lithium beam diagnostic

    SciTech Connect

    Brix, M.; Morgan, P.; Stamp, M.; Zastrow, K.-D.; Dunai, D.; Meszaros, B.; Petravich, G.; Refy, D. I.; Szabolics, T.; Zoletnik, S.; Lupelli, I.; Marsen, S.; Melson, T. F.; Silva, C. [EURATOM Collaboration: JET-EFDA Contributors

    2012-10-15

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  1. Beamlet laser diagnostics

    SciTech Connect

    Burkhart, S.C.; Behrendt, W.C.; Smith, I.

    1996-06-01

    Beamlet is instrumented extensively to monitor the performance of the overall laser system and many of its subsystems. Beam diagnostics, installed in key locations, are used to fully characterize the beam during its propagation through the multipass cavity and the laser`s output section. This article describes the diagnostics stations located on Beamlet and discusses the design, calibration, and performance of the Beamlet calorimeters. The authors used Nova`s diagnostics packages to develop the Beamlet design to determine beam energy, spatial profile, temporal profile, and other beam parameters. Technologic improvements within the last several years in controls, charge-coupled device (CCD) cameras, and fast oscilloscopes have allowed the authors to obtain more accurate measurements on the Beamlet laser system. They briefly cover some of these techniques, including a description of their LabVIEW based data acquisition system.

  2. [Peripheral neuropathies: Diagnostic strategy].

    PubMed

    Magy, L

    2017-02-28

    Diagnosing a peripheral neuropathy is sometimes challenging, as the causes are diverse and the clinical pictures heterogeneous. Overall, diagnosing a patient with peripheral neuropathy will require some knowledge in almost every field of medicine. Therefore, it appears crucial to adopt a diagnostic strategy that is based on solid clinical and neurophysiological grounds. The present paper describes a three-step diagnostic strategy: (1) to delineate a clinico-pathologic entity from clinical and electrodiagnostic findings; (2) to propose a list of plausible causes based on step one, history and clinical context; (3) to use appropriate workup in order to determine the cause or mechanism of the neuropathy. The three steps of this diagnostic strategy necessitate a high level of expertise and interaction between physicians is highly desirable. Finally, an aggressive course and a severe impairment should lead to relentlessly look for a curable cause.

  3. [Molecular diagnostics in pathology].

    PubMed

    Stenzinger, A; Penzel, R; Endris, V; Weichert, W

    2013-05-01

    Tissue-based molecular diagnostics is a fast growing diagnostic field, which already complements morphologic classifications in many cases. Pathology based molecular diagnosis is performed almost exclusively on paraffin embedded material and always in conjunction with histopathology. Besides the classic field of tissue based detection of pathogenic organisms such as bacteria, viruses and fungi, molecular diagnostics of tumor tissue is one of the current hot topics in oncology. In this context the detection of predictive molecular biomarkers, such as specific mutations, allows patient stratification for individually tailored treatment strategies and thereby is one of the key components of individualized patient care in oncology. The rapidly growing number of clinically relevant predictive biomarkers together with impressive technical advances, specifically the development of massive parallel sequencing, will modify the care of patients with malignant diseases. Pathology, therefore, has returned in the very center of interdisciplinary patient care.

  4. ORION laser target diagnostics.

    PubMed

    Bentley, C D; Edwards, R D; Andrew, J E; James, S F; Gardner, M D; Comley, A J; Vaughan, K; Horsfield, C J; Rubery, M S; Rothman, S D; Daykin, S; Masoero, S J; Palmer, J B; Meadowcroft, A L; Williams, B M; Gumbrell, E T; Fyrth, J D; Brown, C R D; Hill, M P; Oades, K; Wright, M J; Hood, B A; Kemshall, P

    2012-10-01

    The ORION laser facility is one of the UK's premier laser facilities which became operational at AWE in 2010. Its primary mission is one of stockpile stewardship, ORION will extend the UK's experimental plasma physics capability to the high temperature, high density regime relevant to Atomic Weapons Establishment's (AWE) program. The ORION laser combines ten laser beams operating in the ns regime with two sub ps short pulse chirped pulse amplification beams. This gives the UK a unique combined long pulse/short pulse laser capability which is not only available to AWE personnel but also gives access to our international partners and visiting UK academia. The ORION laser facility is equipped with a comprehensive suite of some 45 diagnostics covering optical, particle, and x-ray diagnostics all able to image the laser target interaction point. This paper focuses on a small selection of these diagnostics.

  5. Evaluation of User Performance in Simulation-Based Diagnostic Cerebral Angiography Training.

    PubMed

    Zaika, Oleksiy; Nguyen, Ngan; Boulton, Mel; Eagleson, Roy; de Ribaupierre, Sandrine

    2016-01-01

    Simulation of anatomically complex procedures, such as angiography, is becoming more practical, however, computer-based modules require extensive research to assess their effectiveness. We organized two training schemas - alternating cases and consistent cases - and hypothesized that the alternating practice cases would be beneficial to test performance. Eight residents (4 radiology/4 neurosurgery) and 8 anatomy graduate students were trained on the Simbionix™ simulator in order to assess skill acquisition in diagnostic cerebral angiography over 8 sessions. We found that participants improve on total procedure time and total fluoroscopy time (p<0.05), but not on contrast injected or roadmaps created. There were no significant differences between alternating and consistent training types. Additional work needs to be done with higher sample numbers and visuospatial scores as criteria.

  6. Automatic Generation of Conditional Diagnostic Guidelines.

    PubMed

    Baldwin, Tyler; Guo, Yufan; Syeda-Mahmood, Tanveer

    2016-01-01

    The diagnostic workup for many diseases can be extraordinarily nuanced, and as such reference material text often contains extensive information regarding when it is appropriate to have a patient undergo a given procedure. In this work we employ a three task pipeline for the extraction of statements indicating the conditions under which a procedure should be performed, given a suspected diagnosis. First, we identify each instance in the text where a procedure is being recommended. Next we examine the context around these recommendations to extract conditional statements that dictate the conditions under which the recommendation holds. Finally, corefering recommendations across the document are linked to produce a full recommendation summary. Results indicate that each underlying task can be performed with above baseline performance, and the output can be used to produce concise recommendation summaries.

  7. Automatic Generation of Conditional Diagnostic Guidelines

    PubMed Central

    Baldwin, Tyler; Guo, Yufan; Syeda-Mahmood, Tanveer

    2016-01-01

    The diagnostic workup for many diseases can be extraordinarily nuanced, and as such reference material text often contains extensive information regarding when it is appropriate to have a patient undergo a given procedure. In this work we employ a three task pipeline for the extraction of statements indicating the conditions under which a procedure should be performed, given a suspected diagnosis. First, we identify each instance in the text where a procedure is being recommended. Next we examine the context around these recommendations to extract conditional statements that dictate the conditions under which the recommendation holds. Finally, corefering recommendations across the document are linked to produce a full recommendation summary. Results indicate that each underlying task can be performed with above baseline performance, and the output can be used to produce concise recommendation summaries. PMID:28269823

  8. Bariatric Surgery Procedures

    MedlinePlus

    ... Center Access to Care Toolkit EHB Access Toolkit Bariatric Surgery Procedures Bariatric surgical procedures cause weight loss by ... minimally invasive techniques (laparoscopic surgery). The most common bariatric surgery procedures are gastric bypass, sleeve gastrectomy, adjustable gastric ...

  9. [Complex diagnostics of osteosarcomas].

    PubMed

    Muradov, Kh K; Sadykhova, G G

    2014-01-01

    It was analyzed the examination results of 156 patients with osteosarcoma. The data show that definition of histogenetic source, diagnostics and prognosis of treatment results are possible and expedient in case of analysis of signs reflecting tumor cells specificity. These signs may be determined by using of clinical parameters, X-ray imaging and light microscopy in case of moderately and highly differentiated sarcomas. Ample opportunities of flow citometry and immunohistochemistry allow to perform histogenetic identification, differential diagnostics and prognosis for low-grade sarcomas.

  10. Diagnostic hematology of reptiles.

    PubMed

    Stacy, Nicole I; Alleman, A Rick; Sayler, Katherine A

    2011-03-01

    The hematologic evaluation of reptiles is an indispensable diagnostic tool in exotic veterinary practice. The diversity of reptile species, their characteristic physiologic features, and effects of intrinsic and extrinsic factors present unique challenges for accurate interpretation of the hemogram. Combining the clinical presentation with hematologic findings provides valuable information in the diagnosis and monitoring of disease and helps guide the clinician toward therapy and further diagnostic testing. This article outlines the normal and pathologic morphology of blood cells of reptile species. The specific comparative aspects of reptiles are emphasized, and structural and functional abnormalities in the reptilian hemogram are described.

  11. Performance of advanced trauma life support procedures in microgravity

    NASA Technical Reports Server (NTRS)

    Campbell, Mark R.; Billica, Roger D.; Johnston, Smith L 3rd; Muller, Matthew S.

    2002-01-01

    BACKGROUND: Medical operations on the International Space Station will emphasize the stabilization and transport of critically injured personnel and so will need to be capable of advanced trauma life support (ATLS). METHODS: We evaluated the ATLS invasive procedures in the microgravity environment of parabolic flight using a porcine animal model. Included in the procedures evaluated were artificial ventilation, intravenous infusion, laceration closure, tracheostomy, Foley catheter drainage, chest tube insertion, peritoneal lavage, and the use of telemedicine methods for procedural direction. RESULTS: Artificial ventilation was performed and appeared to be unaltered from the 1-G environment. Intravenous infusion, laceration closure, percutaneous dilational tracheostomy, and Foley catheter drainage were achieved without difficulty. Chest tube insertion and drainage were performed with no more difficulty than in the 1-G environment due to the ability to restrain patient, operator and supplies. A Heimlich valve and Sorenson drainage system were both used to provide for chest tube drainage collection with minimal equipment, without the risk of atmospheric contamination, and with the capability to auto-transfuse blood drained from a hemothorax. The use of telemedicine in chest tube insertion was demonstrated to be useful and feasible. Peritoneal lavage using a percutaneous technique, although requiring less training to perform, was found to be dangerous in weightlessness due to the additional pressure of the bowel on the anterior abdominal wall creating a high risk of bowel perforation. CONCLUSIONS: The performance of ATLS procedures in microgravity appears to be feasible with the exception of diagnostic peritoneal lavage. Minor modifications to equipment and techniques are required in microgravity to effect surgical drainage in the presence of altered fluid dynamics, to prevent atmospheric contamination, and to provide for the restraint requirements. A parabolic

  12. Radial access for cerebrovascular procedures: Case report and technical note

    PubMed Central

    Vance, Ansar Z; Sivapatham, Thinesh

    2015-01-01

    Background Advantages of radial access over brachial/axillary or femoral access have been well described for several decades and include decreased cost, patient preference, and decreased major access site complications. Despite these advantages, radial access is rarely employed or even considered for neurointerventional procedures. This attitude should be reconsidered given several recent large, randomized, controlled trials from the cardiovascular literature proving that radial access is associated with statistically lower costs, decreased incidence of myocardial infarctions, strokes, and even decreased mortality. Radial access is now considered the standard of care for percutaneous coronary interventions in most US centers. Although radial access has been described for neurovascular procedures in the past, overall experience is limited. The two major challenges are the unique anatomy required to access the cerebral vasculature given very acute angles between the arm and craniocervical vessels and limitations in available technology. Methods We present a simplified approach to radial access for cerebrovascular procedures and provide a concise step-by-step approach for patient selection, ultrasound-guided single-wall access, recommended catheters/wires, and review of patent hemostasis. Additionally, we present a complex cerebrovascular intervention in which standard femoral access was unsuccessful, while radial access was quickly achieved to highlight the importance of familiarity with the radial approach for all neurointerventionalists. Results We have found that the learning curve is not too steep and that the radial access approach can be adopted smoothly for a large percentage of diagnostic and interventional neuroradiologic procedures. Conclusions Radial access should be considered in all patients undergoing a cerebrovascular procedure. PMID:26659807

  13. Practical Diagnostics for Evaluating Residential Commissioning Metrics

    SciTech Connect

    Wray, Craig; Walker, Iain; Siegel, Jeff; Sherman, Max

    2002-06-11

    In this report, we identify and describe 24 practical diagnostics that are ready now to evaluate residential commissioning metrics, and that we expect to include in the commissioning guide. Our discussion in the main body of this report is limited to existing diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. Appendix C describes the 83 other diagnostics that we have examined in the course of this project, but that are not ready or are inappropriate for residential commissioning. Combined with Appendix B, Table 1 in the main body of the report summarizes the advantages and disadvantages of all 107 diagnostics. We first describe what residential commissioning is, its characteristic elements, and how one might structure its process. Our intent in this discussion is to formulate and clarify these issues, but is largely preliminary because such a practice does not yet exist. Subsequent sections of the report describe metrics one can use in residential commissioning, along with the consolidated set of 24 practical diagnostics that the building industry can use now to evaluate them. Where possible, we also discuss the accuracy and usability of diagnostics, based on recent laboratory work and field studies by LBNL staff and others in more than 100 houses. These studies concentrate on evaluating diagnostics in the following four areas: the DeltaQ duct leakage test, air-handler airflow tests, supply and return grille airflow tests, and refrigerant charge tests. Appendix A describes those efforts in detail. In addition, where possible, we identify the costs to purchase diagnostic equipment and the amount of time required to conduct the diagnostics. Table 1 summarizes these data. Individual equipment costs for the 24

  14. [Enuresis and pediatric urinary incontinence : Diagnostics and therapy].

    PubMed

    Schultz-Lampel, D; Goepel, M; Reitz, A; Braun, P

    2016-12-01

    Differentiated non-invasive diagnostic procedures allow a discrimination between nocturnal enuresis and behavior-linked urinary incontinence in children with daytime symptoms, which are different entities of a pathological pediatric micturition syndrome. The article describes the diagnostic procedure as well as the therapeutic approach to all forms of micturition disorders in childhood. All behavioral, medical and biofeedback therapeutic methods according to the recently published S2k guidelines from the Association of the Scientific Medical Societies in Germany (AWMF) on enuresis and non-organic (functional) incontinence in children and adolescents are mentioned and discussed.

  15. EMC Recent Additions

    EPA Pesticide Factsheets

    This page has information about recent changes to promulgated and proposed test methods, perfomance specifications, and quality assurance procedures. It also includes updates and changes to all other approved and proposed test methods.

  16. Studies and analyses of the Space Shuttle Main Engine: SSME failure data review, diagnostic survey and SSME diagnostic evaluation

    NASA Technical Reports Server (NTRS)

    Glover, R. C.; Kelley, B. A.; Tischer, A. E.

    1986-01-01

    The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.

  17. Equivalent Diagnostic Classification Models

    ERIC Educational Resources Information Center

    Maris, Gunter; Bechger, Timo

    2009-01-01

    Rupp and Templin (2008) do a good job at describing the ever expanding landscape of Diagnostic Classification Models (DCM). In many ways, their review article clearly points to some of the questions that need to be answered before DCMs can become part of the psychometric practitioners toolkit. Apart from the issues mentioned in this article that…

  18. Sexual Addiction: Diagnostic Problems

    ERIC Educational Resources Information Center

    Giugliano, John R.

    2009-01-01

    In recent years clinicians report a great deal of concern about definition, diagnostic assessment, and treatment modalities when dealing with what might be called out-of-control sexual behavior. Many terms have been used to describe the phenomenon of problematic sexual behavior. Many of these concepts overlap, some are no longer popular, and some…

  19. Tele diagnostic by web

    NASA Astrophysics Data System (ADS)

    Sugiyama, Shigeki

    2006-03-01

    Because of the development of multimedia technologies like Web and Internet, it now becomes possible to think about Tele Medicine and Tele Diagnostic for a distant place where no doctors and no nurses are situated at or are available. And also some kind of intelligence can be added onto them, which makes possible to give certain kind of medical treatment assistance or suggestions for a patient from a computer diagnostic base through the Internetworking. For doing this, here considers about a basic system of "Tele Diagnostic for a remote place" where it dose not have a doctor and a medical assistance. In order to implement the system, JAVA, VRML, HTML, and CORTONA are used as a basic language and a viewer. And also in order to add a kind of intelligence, Augmented Knowledge In Agent (AKIA) by using Back Propagation Neural Networks (BPNN) is used. And by this study, here can introduce the system that has the following basic mechanisms; By inputting physical data like temperature or blood pressure, the system would show a diagnostic assistance by TEXT. And also the bad place of body would be shown graphically if there were any. The system can be put onto Web, so that anybody could have this assistance at any place ubiquitously only if a person has Internetworking access.

  20. ESPC Integrated Skill Diagnostics

    DTIC Science & Technology

    2015-09-30

    monitoring systems for gauging performance of the ESPC. This is an integral part of the overall ESPC goal of developing a global coupled system between...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. ESPC Integrated Skill Diagnostics Maria Flatau Naval...quantitative skill metrics to assess the advancements in the Earth System Prediction Capability (ESPC). This work will also implement automated

  1. Diagnostic peritoneal lavage - slideshow

    MedlinePlus

    ... Indication URL of this page: //medlineplus.gov/ency/presentations/100159.htm Diagnostic peritoneal lavage - series—Indication To use the sharing features on this page, please enable JavaScript. Go to slide 1 out of 4 Go to slide 2 ...

  2. Diagnostics for induction accelerators

    SciTech Connect

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960`s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore`s Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail.

  3. Diagnosing Diagnostic Language Assessment

    ERIC Educational Resources Information Center

    Lee, Yong-Won

    2015-01-01

    Diagnostic language assessment (DLA) is gaining a lot of attention from language teachers, testers, and applied linguists. With a recent surge of interest in DLA, there seems to be an urgent need to assess where the field of DLA stands at the moment and develop a general sense of where it should be moving in the future. The current article, as the…

  4. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  5. General considerations and updates in pediatric gastrointestinal diagnostic endoscopy

    PubMed Central

    2010-01-01

    Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965

  6. [Classification and diagnostics of multiresistant bacteria].

    PubMed

    Schneider, C M; Serr, A

    2010-04-01

    Multidrug-resistant organisms are spreading worldwide. Chromosomally encoded resistance mechanisms are spread by clonal expansion, e.g., methicillin-resistant Staphylococcus aureus strains. Plasmid-encoded mechanisms such as extended-spectrum beta-lactamases spread even more efficiently because they can also be horizontally transferred into other species. Acquisition of additional resistance genes minimizes therapeutic options and leads to frequent treatment failure. Laboratory diagnostics is laborious and time-consuming and requires combinations of different phenotypic and molecular methods. Increasing knowledge of treatment and diagnostics is essential for physicians.

  7. [Inflammatory bowel diseases--imaging diagnostics].

    PubMed

    Gil, Jerzy; Wojtuń, Stanisław; Stec-Michalska, Krystyna; Chojnacki, Cezary

    2004-01-01

    The basic diagnostic procedure in ulcerative colitis is an endoscopy of gastrointestinal tract. It allows the macroscopic evaluation as well as the specimen taking for histological assessment what is the basis for ultimate diagnosis. In case of Crohn's disease the radiological diagnostics is of equal importance as endoscope evaluation. The imaging of inflammatory changes in Crohn's disease still poses some difficulties, especially, that located in the small intestine. Lately, the range of accessible examinations has been wider. We have in disposal the ultrasonography, the computed tomography, the magnetic resonance imaging and the capsular endoscopy. All of them are of great use in the diagnosis of Crohn's disease. In case of microscopic colitis all the imaging diagnostics has no use. The only one mean to establish the diagnosis is a histological assessment. What is more, in the period of remission the colon tissue could be normal. In this paper we discussed the traditional and contemporary intestine imaging methods in inflammatory bowel diseases. The conclusion is that the further progress in science offers a better imaging and, what is even more important, the more efficient diagnostics and treatment of these diseases.

  8. Personalized Medicine’s Bottleneck: Diagnostic Test Evidence and Reimbursement

    PubMed Central

    Cohen, Joshua P.; Felix, Abigail E.

    2014-01-01

    Background: Personalized medicine is gradually emerging as a transformative field. Thus far, seven co-developed drug-diagnostic combinations have been approved and several dozen post-hoc drug-diagnostic combinations (diagnostic approved after the drug). However, barriers remain, particularly with respect to reimbursement. Purpose, methods: This study analyzes barriers facing uptake of drug-diagnostic combinations. We examine Medicare reimbursement in the U.S. of 10 drug-diagnostic combinations on the basis of a formulary review and a survey. Findings: We found that payers reimburse all 10 drugs, but with variable and relatively high patient co-insurance, as well as imposition of formulary restrictions. Payer reimbursement of companion diagnostics is limited and highly variable. In addition, we found that the body of evidence on the clinical- and cost-effectiveness of therapeutics is thin and even less robust for diagnostics. Conclusions, discussion: The high cost of personalized therapeutics and dearth of evidence concerning the comparative clinical effectiveness of drug-diagnostic combinations appear to contribute to high patient cost sharing, imposition of formulary restrictions, and limited and variable reimbursement of companion diagnostics. Our findings point to the need to increase the evidence base supportive of establishing linkage between diagnostic testing and positive health outcomes. PMID:25563222

  9. Radiation injuries after fluoroscopic procedures.

    PubMed

    Mettler, Fred A; Koenig, Titus R; Wagner, Louis K; Kelsey, Charles A

    2002-10-01

    Fluoroscopically guided diagnostic and interventional procedures have become much more commonplace over the last decade. Current fluoroscopes are easily capable of producing dose rates in the range of 0.2 Gy (20 rads) per minute. The dose rate often changes dramatically with patient positioning and size. Most machines currently in use have no method to display approximate patient dose other than the rough surrogate of total fluoroscopy time. This does not include patient dose incurred during fluorography (serial imaging or cine runs), which can be considerably greater than dose during fluoroscopy. There have been over 100 cases of documented radiation skin and underlying tissue injury, a large portion of which resulted in dermal necrosis. The true number of injuries is undoubtedly much higher. The highest dose procedures are complex interventions such as those involving percutaneous angioplasties, stent placements, embolizations, and TIPS. In some cases skin doses have been in excess of 60 Gy (6000 rads). In many instances the procedures have been performed by physicians with little training in radiation effects, little appreciation of the radiation injuries that are possible or the strategies that could have been used to reduce both patient and staff doses. Almost all of the severe injuries that have occurred were avoidable.

  10. Phylogenetic characterisation of feline immunodeficiency virus in naturally infected cats in Croatia indicates additional heterogeneity of subtype B in Europe.

    PubMed

    Perharić, Matko; Biđin, Marina; Starešina, Vilim; Milas, Zoran; Turk, Nenad; Štritof, Zrinka; Hađina, Suzana; Habuš, Josipa; Stevanović, Vladimir; Mojčec-Perko, Vesna; Kovač, Snježana; Martinković, Krešimir; Barbić, Ljubo

    2016-09-01

    This study was performed on 29 domestic cats with a variety of clinical signs, possibly related to FIV infection. Blood samples were tested by a rapid immunochromatographic (ICA) procedure for detection of FIV antibodies. Subsequently, polymerase chain reaction (PCR) was performed to amplify a portion of the proviral gag gene. All 11 positive PCR products were sequenced and compared with previously reported FIV sequences. Croatian proviral isolates that could be amplified were clustered within subtype B, and additional heterogeneity was confirmed by the formation of three separate clusters. Phylogenetic analysis of circulating strains in Croatia and in southeast Europe is necessary to improve diagnostic methods and selection of the appropriate vaccinal strains.

  11. Intraepidermal Nerve Fiber Density: Diagnostic and Therapeutic Relevance in the Management of Chronic Pruritus: a Review.

    PubMed

    Pereira, Manuel P; Mühl, Sebastian; Pogatzki-Zahn, Esther M; Agelopoulos, Konstantin; Ständer, Sonja

    2016-12-01

    In recent years, measurement of the intraepidermal nerve fiber (IENF) density has gained relevance in the diagnostics of chronic pruritus. This method allows the objectification and quantification of a small-fiber neuropathy, which may manifest clinically with pruritus, pain or dysesthetic sensory symptoms, such as burning, stinging and tingling sensations or numbness. Upon suspicion of a small-fiber neuropathy as a cause for chronic pruritus, targeted diagnostic procedures are essential for the early detection of the neuroanatomical changes. After a punch biopsy of the lower leg, the obtained tissue undergoes an immunofluorescence staining process with a primary antibody against the protein gene product 9.5. The IENFs can thus be detected and are quantified according to pre-determined guidelines based on an international consensus. In addition to morphological changes, functional impairment of small-fibers can be assessed using quantitative sensory testing by assessing detection and pain thresholds of various thermal and mechanic modalities. This method, however, is time-consuming and requires a specialized investigator, and thus it is not routinely used in the diagnostic investigation of chronic pruritus. Diagnosing a small-fiber neuropathy underlying chronic pruritus has therapeutic relevance. If possible, the underlying cause of the neuropathy should be treated. Alternatively, symptomatic therapy options include topical (capsaicin) and systemic (anticonvulsants and/or antidepressants) agents. Chronification processes may lead to refractory pruritus, and thus treatment should be initiated as soon as possible. The aim of this review is to present and discuss the measurement of the IENF density as a diagnostic tool and its role in the management of patients with chronic pruritus. A brief case report is presented to better illustrate the role of this diagnostic method in the clinical setting.

  12. DIAGNOSTICS OF BNL ERL

    SciTech Connect

    POZDEYEV,E.; BEN-ZVI, I.; CAMERON, P.; GASSNER, D.; KAYRAN, D.; ET AL.

    2007-06-25

    The ERL Prototype project is currently under development at the Brookhaven National Laboratory. The ERL is expected to demonstrate energy recovery of high-intensity beams with a current of up to a few hundred milliamps, while preserving the emittance of bunches with a charge of a few nanocoulombs produced by a high-current SRF gun. To successfully accomplish this task the machine will include beam diagnostics that will be used for accurate characterization of the three dimensional beam phase space at the injection and recirculation energies, transverse and longitudinal beam matching, orbit alignment, beam current measurement, and machine protection. This paper outlines requirements on the ERL diagnostics and describes its setup and modes of operation.

  13. ICF diagnostics. Revision 1

    SciTech Connect

    Coleman, L.W.

    1982-12-17

    In the past several years there have been significant advances and accomplishments in the field of Inertial Confinement Fusion (ICF) research which are directly attributable to an active experimental program supported by the development and applications of sophisticated and specialized diagnostics instruments and techniques. The continued development of high temporal-and spatial-resolution diagnostics, although with a somewhat different technical emphasis than previously, is essential for maintaining progress in ICF. With the generation of inertial fusion drivers now becoming available progress toward higher density compression of fusion fuel will be attained at the expense of temperature, and consequently emissions from the targets will be limited. At the same time since the targets are being driven to higher density they are more opaque to the low-to-moderate energy x-rays (up to a few keV) and particles (alpha particles, protons, and knock-on charged particles) that have been utilized for diagnosing target performance.

  14. Cardiovascular modeling and diagnostics

    SciTech Connect

    Kangas, L.J.; Keller, P.E.; Hashem, S.; Kouzes, R.T.

    1995-12-31

    In this paper, a novel approach to modeling and diagnosing the cardiovascular system is introduced. A model exhibits a subset of the dynamics of the cardiovascular behavior of an individual by using a recurrent artificial neural network. Potentially, a model will be incorporated into a cardiovascular diagnostic system. This approach is unique in that each cardiovascular model is developed from physiological measurements of an individual. Any differences between the modeled variables and the variables of an individual at a given time are used for diagnosis. This approach also exploits sensor fusion to optimize the utilization of biomedical sensors. The advantage of sensor fusion has been demonstrated in applications including control and diagnostics of mechanical and chemical processes.

  15. Bronchoscopic procedures and lung biopsies in pediatric lung transplant recipients.

    PubMed

    Wong, Jackson Y; Westall, Glen P; Snell, Gregory I

    2015-12-01

    Bronchoscopy remains a pivotal diagnostic and therapeutic intervention in pediatric patients undergoing lung transplantation (LTx). Whether performed as part of a surveillance protocol or if clinically indicated, fibre-optic bronchoscopy allows direct visualization of the transplanted allograft, and in particular, an assessment of the patency of the bronchial anastomosis (or tracheal anastomosis following heart-lung transplantation). Additionally, bronchoscopy facilitates differentiation of infective processes from rejection episodes through collection and subsequent assessment of bronchoalveolar lavage (BAL) and transbronchial biopsy (TBBx) samples. Indeed, the diagnostic criteria for the grading of acute cellular rejection is dependent upon the histopathological assessment of biopsy samples collected at the time of bronchoscopy. Typically, performed in an out-patient setting, bronchoscopy is generally a safe procedure, although complications related to hemorrhage and pneumothorax are occasionally seen. Airway complications, including stenosis, malacia, and dehiscence are diagnosed at bronchoscopy, and subsequent management including balloon dilatation, laser therapy and stent insertion can also be performed bronchoscopically. Finally, bronchoscopy has been and continues to be an important research tool allowing a better understanding of the immuno-biology of the lung allograft through the collection and analysis of collected BAL and TBBx samples. Whilst new investigational tools continue to evolve, the simple visualization and collection of samples within the lung allograft by bronchoscopy remains the gold standard in the evaluation of the lung allograft. This review describes the use and experience of bronchoscopy following lung transplantation in the pediatric setting.

  16. Endodontic diagnostic terminology update.

    PubMed

    McClannahan, Scott B; Baisden, Michael K; Bowles, Walter R

    2011-01-01

    Determination of the etiology of the patient's chief complaint and a correct diagnosis are paramount prior to a recommendation of endodontic therapy. Reproduction of the patient's chief complaint is critical. If the chief complaint cannot be reproduced, consider consultation with or referral to an endodontist or orofacial pain specialist. The diagnostic terminology presented in this update provides for a more accurate description and communication of the health or pathological conditions of both pulpal and apical tissues. This information is summarized in Table I.

  17. Microsphere based saliva diagnostics

    NASA Astrophysics Data System (ADS)

    Rissin, David M.; DiCesare, Christopher; Hayman, Ryan B.; Blicharz, Timothy M.; Walt, David R.

    2005-11-01

    Saliva presents a minimally invasive alternative medium to blood for performing diagnostics1. Microsphere sensors for ions, small organic molecules, and proteins are currently being developed and optical microarrays containing thousands of these sensors will be used for simultaneous multi-analyte analysis. The fiber bundle platform in use is 1mm in diameter and contains approximately 50,000 individually addressable 3.1μm fibers, each with an etched well capable of housing a single 3.1μm microsphere sensor. Micron-sized bead-based chemistries are produced in house, followed by deposition onto a fiber-optic bundle platform, allowing for multiplexed analysis. The ultimate goal is to develop a universal diagnostic system using saliva as the diagnostic medium. This platform will permit multiplexed analysis of a sample by integrating microfluidics with the optical arrays loaded with sensors capable of detecting relevant biomarkers associated with a wide range of disease states. Disease states that are currently under investigation include end stage renal disease (ESRD) and Sjoegrens Syndrome (SS).

  18. Microgravity Combustion Diagnostics Workshop

    NASA Technical Reports Server (NTRS)

    Santoro, Gilbert J. (Editor); Greenberg, Paul S. (Editor); Piltch, Nancy D. (Editor)

    1988-01-01

    Through the Microgravity Science and Applications Division (MSAD) of the Office of Space Science and Applications (OSSA) at NASA Headquarters, a program entitled, Advanced Technology Development (ATD) was promulgated with the objective of providing advanced technologies that will enable the development of future microgravity science and applications experimental flight hardware. Among the ATD projects one, Microgravity Combustion Diagnostics (MCD), has the objective of developing advanced diagnostic techniques and technologies to provide nonperturbing measurements of combustion characteristics and parameters that will enhance the scientific integrity and quality of microgravity combustion experiments. As part of the approach to this project, a workshop was held on July 28 and 29, 1987, at the NASA Lewis Research Center. A small group of laser combustion diagnosticians met with a group of microgravity combustion experimenters to discuss the science requirements, the state-of-the-art of laser diagnostic technology, and plan the direction for near-, intermediate-, and long-term programs. This publication describes the proceedings of that workshop.

  19. [Histopathological meniscus diagnostic].

    PubMed

    Fisseler-Eckhoff, A; Müller, K-M

    2009-06-01

    Menisci fulfill many functions within the complex biomechanics of the knee joint. In the case of meniscus lesions, sparing arthroscopic resections and operative refixation are the treatments of choice. With regard to diagnostics, this means that in general terms, the histopathologic diagnostics are carried out on detached meniscus fragments of between 5 mm and 2 cm in size. An experienced pathologist's knowledge of physiologically possible cellular and fibrous histological meniscus damage, as opposed to nonphysiological change regarded as normal with respect to age, is essential during a diagnostic meniscus evaluation. The clinician expects clear statements from the pathologist regarding the severity of previous or secondary degenerative meniscus damage, the age and type of traumatic tears, and appraisal of the relationship between trauma and meniscus damage from an insurance point of view. Close cooperation between the clinician and the pathologist allows for fast and unambiguous correlation of anamnesis, the clinical picture, and morphological reporting so that cases involving insurance problems - which are numerous, often long-term, and often unsatisfactory - can be clarified quickly.

  20. Alpha Particle Diagnostic

    SciTech Connect

    Fisher, Ray, K.

    2009-05-13

    The study of burning plasmas is the next frontier in fusion energy research, and will be a major objective of the U.S. fusion program through U.S. collaboration with our international partners on the ITER Project. For DT magnetic fusion to be useful for energy production, it is essential that the energetic alpha particles produced by the fusion reactions be confined long enough to deposit a significant fraction of their initial ~3.5 MeV energy in the plasma before they are lost. Development of diagnostics to study the behavior of energetic confined alpha particles is a very important if not essential part of burning plasma research. Despite the clear need for these measurements, development of diagnostics to study confined the fast confined alphas to date has proven extremely difficult, and the available techniques remain for the most part unproven and with significant uncertainties. Research under this grant had the goal of developing diagnostics of fast confined alphas, primarily based on measurements of the neutron and ion tails resulting from alpha particle knock-on collisions with the plasma deuterium and tritium fuel ions. One of the strengths of this approach is the ability to measure the alphas in the hot plasma core where the interesting ignition physics will occur.

  1. Microwave diagnostics of atmospheric plasmas

    NASA Astrophysics Data System (ADS)

    Scott, David

    Plasma treatment of biological tissues has tremendous potential due to the wide range of applications. Most plasmas have gas temperatures which greatly exceed room temperature. These are often utilized in electro-surgery for cutting and coagulating tissue. Another type of plasma, referred to as cold atmospheric plasma, or CAP, is characterized by heavy particle temperatures which are at or near room temperature. Due to this lack of thermal effect, CAP may provide less invasive medical procedures. Additionally, CAP have been demonstrated to be effective at targeting cancer cells while minimizing damage to the surrounding tissue. A recently fabricated Microwave Electron Density Device (MEDD) utilizes microwave scattering on small atmospheric plasmas to determine the electron plasma density. The MEDD can be utilized on plasmas which range from a fraction of a millimeter to several centimeters at atmospheric pressure when traditional methods cannot be applied. Microwave interferometry fails due to the small size of the plasma relative to the microwave wavelength which leads to diffraction and negligible phase change; electrostatic probes introduce very strong perturbation and are associated with difficulties of application in strongly-collisional atmospheric conditions; and laser Thomson scattering is not sensitive enough to measure plasma densities less than 1012 cm-3. The first part of this dissertation provides an overview of two types of small atmospheric plasma objects namely CAPs and plasmas utilized in the electro-surgery. It then goes on to describe the fabrication, testing and calibration of the MEDD facility. The second part of this dissertation is focused on the application of the MEDD and other diagnostic techniques to both plasma objects. A series of plasma images that illustrate the temporal evolution of a discharge created by an argon electrosurgical device operating in the coagulation mode and its behavior was analyzed. The discharge of the argon

  2. A New Diagnostic Test for Endometrial Cancer?

    PubMed Central

    Guralp, Onur; Sheridan, Susan M.; Harter, Josephine; Hinshaw, James Louis; Seo, Songwon; Hartenbach, Ellen M.; Lindheim, Steven; Stewar, Sarah; Kushner, David M.

    2014-01-01

    Objective During saline-infused sonohysterography (SIS), the distension fluid is typically discarded. If cytology analysis could identify those patients with endometrial cancer, many women would be spared from further procedures. Methods Thirty consecutive patients with clinical stage I or II endometrial adenocarcinoma were prospectively recruited preoperatively. Saline-infused sonohysterography was performed by instilling 5 mL of saline, withdrawing and sending for analysis. Saline was reinfused until complete SIS images were obtained and sent separately for cytology. Results Of the 30 women enrolled, SIS was technically successful in 29. Demographics included mean age (60.5 ± 6.99 years), body mass index (35.55 ± 8.18 kg/m2), endometrioid histology (76%), and grade (grade 1, 67%). Prestudy diagnostic method included biopsy (70%), dilatation and curettage (17%), and hysteroscopy (10%). Adequate cytology specimens were obtained in 66% of the 5mL flushes and 72% of the complete SIS collections. Of adequate specimens, the sensitivities to detect endometrial cancer for the 5-mL, complete, and combined fluid samples were 26% (95% confidence interval, 9%–51%), 36% (17%–59%), and 42% (22%–63%). Sensitivity based on the whole study sample (N = 30) was 33% (17%–53%). Statistical significance was not found in the association between a positive test and age, body mass index, grade, diagnostic method, or volume instilled or aspirated. Conclusions Most patients with early endometrial cancer can undergo SIS procedures with adequate cytology specimens obtained from distention media. However, the sensitivity is low, and refinements are necessary before utilizing as a diagnostic test. In cases with positive results, the patient may be able to avoid other costly and painful procedures. PMID:23881100

  3. Photovoltaic array space power plus diagnostics experiment

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1990-01-01

    The objective is to summarize the five years of hardware development and fabrication represented by the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) Instrument. The original PASP Experiment requirements and background is presented along with the modifications which were requested to transform the PASP Experiment into the PASP Plus Instrument. The PASP Plus hardware and software is described. Test results for components and subsystems are given as well as final system tests. Also included are appendices which describe the major subsystems and present supporting documentation such as block diagrams, schematics, circuit board artwork, drawings, test procedures and test reports.

  4. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    PubMed

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  5. Computerized procedures system

    DOEpatents

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  6. Designing Flightdeck Procedures

    NASA Technical Reports Server (NTRS)

    Barshi, Immanuel; Mauro, Robert; Degani, Asaf; Loukopoulou, Loukia

    2016-01-01

    The primary goal of this document is to provide guidance on how to design, implement, and evaluate flight deck procedures. It provides a process for developing procedures that meet clear and specific requirements. This document provides a brief overview of: 1) the requirements for procedures, 2) a process for the design of procedures, and 3) a process for the design of checklists. The brief overview is followed by amplified procedures that follow the above steps and provide details for the proper design, implementation and evaluation of good flight deck procedures and checklists.

  7. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES

    EPA Science Inventory

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  8. Case-Deletion Diagnostics for Nonlinear Structural Equation Models

    ERIC Educational Resources Information Center

    Lee, Sik-Yum; Lu, Bin

    2003-01-01

    In this article, a case-deletion procedure is proposed to detect influential observations in a nonlinear structural equation model. The key idea is to develop the diagnostic measures based on the conditional expectation of the complete-data log-likelihood function in the EM algorithm. An one-step pseudo approximation is proposed to reduce the…

  9. Assessing Fit of Cognitive Diagnostic Models: A Case Study

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Almond, Russell G.

    2007-01-01

    A cognitive diagnostic model uses information from educational experts to describe the relationships between item performances and posited proficiencies. When the cognitive relationships can be described using a fully Bayesian model, Bayesian model checking procedures become available. Checking models tied to cognitive theory of the domains…

  10. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  11. Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures.

    PubMed

    Zuguchi, Masayuki; Chida, Koichi; Taura, Masaaki; Inaba, Yohei; Ebata, Ayako; Yamada, Shogo

    2008-01-01

    At present, interventional radiology (IVR) tends to involve long procedures (long radiation duration), and physicians are near to the source of scattered radiation. Hence, shielding is critical in protecting physicians from radiation. Protective aprons and additional lead-shielding devices, such as tableside lead drapes, are important means of protecting the physician from scattered radiation. The purpose of this study was to evaluate whether non-lead aprons are effective in protecting physicians from radiation during IVR procedures. In this study, the radiation protection effects of commercially available protective lead and non-lead aprons, when exposed to diagnostic X rays, are compared. The performance of these non-lead and lead aprons was similar for scattered X rays at tube voltages of 60-120 kV. Properly designed non-lead aprons are thus more suitable for physicians because they weigh approximately 20% less than the lead aprons, and are non-toxic.

  12. The IHS diagnostic X-ray equipment radiation protection program

    SciTech Connect

    Knapp, A.; Byrns, G.; Suleiman, O.

    1994-05-01

    The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using the National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload.

  13. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Pratt, J. R.; St. Clair, T. L.; Burks, H. D.; Stoakley, D. M.

    1987-01-01

    A method has been found for enhancing the melt flow of thermoplastic polyimides during processing. A high molecular weight 422 copoly(amic acid) or copolyimide was fused with approximately 0.05 to 5 pct by weight of a low molecular weight amic acid or imide additive, and this melt was studied by capillary rheometry. Excellent flow and improved composite properties on graphite resulted from the addition of a PMDA-aniline additive to LARC-TPI. Solution viscosity studies imply that amic acid additives temporarily lower molecular weight and, hence, enlarge the processing window. Thus, compositions containing the additive have a lower melt viscosity for a longer time than those unmodified.

  14. [Food additives and healthiness].

    PubMed

    Heinonen, Marina

    2014-01-01

    Additives are used for improving food structure or preventing its spoilage, for example. Many substances used as additives are also naturally present in food. The safety of additives is evaluated according to commonly agreed principles. If high concentrations of an additive cause adverse health effects for humans, a limit of acceptable daily intake (ADI) is set for it. An additive is a risk only when ADI is exceeded. The healthiness of food is measured on the basis of nutrient density and scientifically proven effects.

  15. Saliva diagnostics - Current views and directions.

    PubMed

    Kaczor-Urbanowicz, Karolina Elżbieta; Martin Carreras-Presas, Carmen; Aro, Katri; Tu, Michael; Garcia-Godoy, Franklin; Wong, David Tw

    2017-03-01

    In this review, we provide an update on the current and future applications of saliva for diagnostic purposes. There are many advantages of using saliva as a biofluid. Its collection is fast, easy, inexpensive, and non-invasive. In addition, saliva, as a "mirror of the body," can reflect the physiological and pathological state of the body. Therefore, it serves as a diagnostic and monitoring tool in many fields of science such as medicine, dentistry, and pharmacotherapy. Introduced in 2008, the term "Salivaomics" aimed to highlight the rapid development of knowledge about various "omics" constituents of saliva, including: proteome, transcriptome, micro-RNA, metabolome, and microbiome. In the last few years, researchers have developed new technologies and validated a wide range of salivary biomarkers that will soon make the use of saliva a clinical reality. However, a great need still exists for convenient and accurate point-of-care devices that can serve as a non-invasive diagnostic tool. In addition, there is an urgent need to decipher the scientific rationale and mechanisms that convey systemic diseases to saliva. Another promising technology called liquid biopsy enables detection of circulating tumor cells (CTCs) and fragments of tumor DNA in saliva, thus enabling non-invasive early detection of various cancers. The newly developed technology-electric field-induced release and measurement (EFIRM) provides near perfect detection of actionable mutations in lung cancer patients. These recent advances widened the salivary diagnostic approach from the oral cavity to the whole physiological system, and thus point towards a promising future of salivary diagnostics for personalized individual medicine applications including clinical decisions and post-treatment outcome predictions. Impact statement The purpose of this mini-review is to make an update about the present and future applications of saliva as a diagnostic biofluid in many fields of science such as dentistry

  16. In-vitro and in-vivo diagnostic techniques for prostate cancer: a review.

    PubMed

    McClure, Patrick; Elnakib, Ahmed; Abou El-Ghar, Mohamed; Khalifa, Fahmi; Soliman, Ahmed; El-Diasty, Tarek; Suri, Jasjit S; Elmaghraby, Adel; El-Baz, Ayman

    2014-10-01

    This paper overviews one of the most important, interesting, and challenging problems in oncology, early diagnosis of prostate cancer. Developing effective diagnostic techniques for prostate cancer is of great clinical importance and can improve the effectiveness of treatment and increase the patient's chance of survival. The main focus of this study is to overview the different in-vitro and in-vivo technologies for diagnosing prostate cancer. This review discusses the current clinically used in-vitro cancer diagnostic tools, such as biomarker tests and needle biopsies and including their applications, advantages, and limitations. Moreover, the current in-vitro research tools that focus on the role of nanotechnology in prostate cancer diagnosis have been detailed. In addition to the in-vitro techniques, the current study discusses in detail developed in-vivo non-invasive state-of-the-art Computer-Aided Diagnosis (CAD) systems for prostate cancer based on analyzing Transrectal Ultrasound (TRUS) and different types of magnetic resonance imaging (MRI), e.g., T2-MRI, Diffusion Weighted Imaging (DWI), Dynamic Contrast Enhanced (DCE)-MRI, and multi-parametric MRI, focusing on their implementation, experimental procedures, and reported outcomes. Furthermore, the paper addresses the limitations of the current prostate cancer diagnostic techniques, outlines the challenges that these techniques face, and introduces the recent trends to solve these challenges, which include biomarkers used in in-vitro lab-on-a-chip nanotechnology-based methods.

  17. HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES

    SciTech Connect

    Ronald L. Boring; David I. Gertman; Katya Le Blanc

    2011-09-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  18. National diagnostic reference level initiative for computed tomography examinations in Kenya

    PubMed Central

    Korir, Geoffrey K.; Wambani, Jeska S.; Korir, Ian K.; Tries, Mark A.; Boen, Patrick K.

    2016-01-01

    The purpose of this study was to estimate the computed tomography (CT) examination frequency, patient radiation exposure, effective doses and national diagnostic reference levels (NDRLs) associated with CT examinations in clinical practice. A structured questionnaire-type form was developed for recording examination frequency, scanning protocols and patient radiation exposure during CT procedures in fully equipped medical facilities across the country. The national annual number of CT examinations per 1000 people was estimated to be 3 procedures. The volume-weighted CT dose index, dose length product, effective dose and NDRLs were determined for 20 types of adult and paediatric CT examinations. Additionally, the CT annual collective effective dose and effective dose per capita were approximated. The radiation exposure during CT examinations was broadly distributed between the facilities that took part in the study. This calls for a need to develop and implement diagnostic reference levels as a standardisation and optimisation tool for the radiological protection of patients at all the CT facilities nationwide. PMID:25790825

  19. Alternative Refractive Surgery Procedures

    MedlinePlus

    ... LASIK Alternative Refractive Surgery Procedures Laser Surgery Recovery Alternative Refractive Surgery Procedures Dec. 12, 2015 Today's refractive ... that releases controlled amounts of radio frequency (RF) energy, instead of a laser, to apply heat to ...

  20. Cosmetic Procedure Questions

    MedlinePlus

    ... Stretch Marks Sun-damaged Skin Unwanted Hair Unwanted Tattoos Varicose Veins Vitiligo Wrinkles Treatments and Procedures Ambulatory ... Stretch Marks Sun-damaged Skin Unwanted Hair Unwanted Tattoos Varicose Veins Vitiligo Wrinkles Treatments and Procedures Ambulatory ...

  1. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James F.

    1968-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.

  2. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James E.; Cobb, E.D.; Kilpatrick, F.A.

    1984-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The outstanding characteristics of dye tracing are: (1) the low detection and measurement limits, and (2) the simplicity and accuracy of measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a general guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section is included on aerial photography because of its possible use to supplement ground-level fluorometry. (USGS)

  3. Fluorometric procedures for dye tracing

    USGS Publications Warehouse

    Wilson, James F.; Cobb, Ernest D.; Kilpatrick, F.A.

    1986-01-01

    This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.

  4. System Related Interventions to Reduce Diagnostic Error: A Narrative Review

    PubMed Central

    Singh, Hardeep; Graber, Mark L.; Kissam, Stephanie M.; Sorensen, Asta V.; Lenfestey, Nancy F.; Tant, Elizabeth M.; Henriksen, Kerm; LaBresh, Kenneth A.

    2013-01-01

    Background Diagnostic errors (missed, delayed, or wrong diagnosis) have gained recent attention and are associated with significant preventable morbidity and mortality. We reviewed the recent literature to identify interventions that have been, or could be, implemented to address systems-related factors that contribute directly to diagnostic error. Methods We conducted a comprehensive search using multiple search strategies. We first identified candidate articles in English between 2000 and 2009 from a PubMed search that exclusively evaluated for articles related to diagnostic error or delay. We then sought additional papers from references in the initial dataset, searches of additional databases, and subject matter experts. Articles were included if they formally evaluated an intervention to prevent or reduce diagnostic error; however, we also included papers if interventions were suggested and not tested in order to inform the state-of-the science on the topic. We categorized interventions according to the step in the diagnostic process they targeted: patient-provider encounter, performance and interpretation of diagnostic tests, follow-up and tracking of diagnostic information, subspecialty and referral-related; and patient-specific. Results We identified 43 articles for full review, of which 6 reported tested interventions and 37 contained suggestions for possible interventions. Empirical studies, though somewhat positive, were non-experimental or quasi-experimental and included a small number of clinicians or health care sites. Outcome measures in general were underdeveloped and varied markedly between studies, depending on the setting or step in the diagnostic process involved. Conclusions Despite a number of suggested interventions in the literature, few empirical studies have tested interventions to reduce diagnostic error in the last decade. Advancing the science of diagnostic error prevention will require more robust study designs and rigorous definitions

  5. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The procedure shall be done in accordance with SAE J1962 “Diagnostic Connector” (JUN92). This incorporation of... part 51. Copies of SAE J1962 may be obtained from the Society of Automotive Engineers, Inc.,...

  6. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The procedure shall be done in accordance with SAE J1962 “Diagnostic Connector” (JUN92). This incorporation of... part 51. Copies of SAE J1962 may be obtained from the Society of Automotive Engineers, Inc.,...

  7. Diagnostic Care: Grade 9. Technology Learning Activity. Teacher Edition. Level 2. Technology Education Series.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…

  8. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    ERIC Educational Resources Information Center

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  9. Patient radiation exposure in diagnostic radiology examinations: an overview. Summary report

    SciTech Connect

    Burkhart, R.L.

    1983-08-01

    The report surveys the published data on entrance skin exposure received by patients during diagnostic radiology examinations. It provides a reference source to aid radiology facilities in determining whether the amount of exposure received by their patients is appropriate for the diagnostic procedures employed.

  10. Procedures for numerical analysis of circadian rhythms

    PubMed Central

    REFINETTI, ROBERTO; LISSEN, GERMAINE CORNÉ; HALBERG, FRANZ

    2010-01-01

    This article reviews various procedures used in the analysis of circadian rhythms at the populational, organismal, cellular and molecular levels. The procedures range from visual inspection of time plots and actograms to several mathematical methods of time series analysis. Computational steps are described in some detail, and additional bibliographic resources and computer programs are listed. PMID:23710111

  11. Planetary Transmission Diagnostics

    NASA Technical Reports Server (NTRS)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  12. Diagnostic and vaccine chapter.

    PubMed

    Wolfram, J H; Kokanov, S K; Verkhovsky, O A

    2010-10-01

    The first report in this chapter describes the development of a killed composite vaccine. This killed vaccine is non-infectious to humans, other animals, and the environment. The vaccine has low reactivity, is non-abortive, and does not induce pathomorphological alterations to the organs of vaccinated animals. The second report of this chapter describes the diagnostic value of a competitive enzyme-linked immunosorbent assay for detecting Brucella-specific antibodies and its ability to discriminate vaccinated cattle from infected cattle. The results indicated that the competitive enzyme-linked immunosorbent assay is more sensitive than traditional tests for detecting antibodies to Brucella abortus in naturally and experimentally infected cattle.

  13. Diagnostics for hybrid reactors

    NASA Astrophysics Data System (ADS)

    Orsitto, Francesco Paolo

    2012-06-01

    The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

  14. Diagnostic Antigens of Leishmania.

    DTIC Science & Technology

    1994-01-31

    braziliensis (MHOM/BR/75/M2903), L. chagasi (MJOM/BR/82/BA-2,C 1), L. donovani (MHOMiEt/67iHU3), Leishmania guyanensis (MIHOMJBR/75/M4147), L. infantum (IPT-1...comparative test to a variety of other recombinant Leishmania antigens including L. chagasi hsp70, L. braziliensis hsp83/90, L. braziliensis eIF4A, L...34 4. AD CONTRACT NO: DAMD17-92-C-2082 EC•£ 2 j 994 ’i, L TITLE: DIAGNOSTIC ANTIGENS OF LEISHMANIA L PRINCIPAL INVESTIGATOR: Steven G. Reed, Ph.D

  15. Diagnostics for hybrid reactors

    SciTech Connect

    Orsitto, Francesco Paolo

    2012-06-19

    The Hybrid Reactor(HR) can be considered an attractive actinide-burner or a fusion assisted transmutation for destruction of transuranic(TRU) nuclear waste. The hybrid reactor has two important subsystems: the tokamak neutron source and the blanket which includes a fuel zone where the TRU are placed and a tritium breeding zone. The diagnostic system for a HR must be as simple and robust as possible to monitor and control the plasma scenario, guarantee the protection of the machine and monitor the transmutation.

  16. Molecular diagnostics for low resource settings

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.

    2010-03-01

    As traditional high quality diagnostic laboratories are not widely available or affordable in developing country health care settings, microfluidics-based point-of-care diagnostics may be able to address the need to perform complex assays in under-resourced areas. Many instrument-based as well as non-instrumented microfluidic prototype diagnostics are currently being developed. In addition to various engineering challenges, the greatest remaining issue is the search for truly low-cost disposable manufacturing methods. Diagnostics for global health, and specifically microfluidics and molecular-based low resource diagnostics, have become a very active research area over the last five years, thanks in part to new funding that became available from the Bill and Melinda Gates Foundation, the National Institutes of Health, and other sources. This has led to a number of interesting prototype devices that are now in advanced development or clinical validation. These devices include disposables and instruments that perform multiplexed PCR-based lab-on-a-chips for enteric, febrile, and vaginal diseases, as well as immunoassays for diseases such as malaria, HIV, and various sexually transmitted diseases. More recently, instrument-free diagnostic disposables based on isothermal nucleic acid amplification have been developed as well. Regardless of platform, however, the search for truly low-cost manufacturing methods that would result in cost of goods per disposable of around US1/unit at volume remains a big challenge. This talk will give an overview over existing platform development efforts as well as present some original research in this area at PATH.

  17. Assessing use of a standardized dental diagnostic terminology in an electronic health record.

    PubMed

    Tokede, Oluwabunmi; White, Joel; Stark, Paul C; Vaderhobli, Ram; Walji, Muhammad F; Ramoni, Rachel; Schoonheim-Klein, Meta; Kimmes, Nicole; Tavares, Anamaria; Kalenderian, Elsbeth

    2013-01-01

    Although standardized terminologies such as the International Classification of Diseases have been in use in medicine for over a century, efforts in the dental profession to standardize dental diagnostic terms have not achieved widespread acceptance. To address this gap, a standardized dental diagnostic terminology, the EZCodes, was developed in 2009. Fifteen dental education institutions in the United States and Europe have implemented the EZCodes dental diagnostic terminology. This article reports on the utilization and valid entry of the EZCodes at three of the dental schools that have adopted this standardized dental diagnostic terminology. Electronic data on the use of procedure codes with diagnostic terms from the three schools over a period from July 2010 to June 2011 were aggregated. The diagnostic term and procedure code pairs were adjudicated by three calibrated dentists. Analyses were conducted to gain insight into the utilization and valid entry of the EZCodes diagnostic terminology in the one-year period. Error proportions in the entry of diagnostic term (and by diagnostic category) were also computed. In the twelve-month period, 29,965 diagnostic terms and 249,411 procedure codes were entered at the three institutions resulting in a utilization proportion of 12 percent. Caries and periodontics were the most frequently used categories. More than 1,000 of the available 1,321 diagnostic terms were never used. Overall, 60.5 percent of the EZCodes entries were found to be valid. The results demonstrate low utilization of EZCodes in an electronic health record and raise the need for specific training of dental providers on the importance of using dental diagnostic terminology and specifically how to use the terms in the electronic record. These findings will serve to increase the use/correct use of the EZCodes dental diagnostic terminology and ultimately create a reliable platform for undertaking clinical, outcomes, and quality improvement-related research.

  18. Advances in paper-based point-of-care diagnostics.

    PubMed

    Hu, Jie; Wang, ShuQi; Wang, Lin; Li, Fei; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng

    2014-04-15

    Advanced diagnostic technologies, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA), have been widely used in well-equipped laboratories. However, they are not affordable or accessible in resource-limited settings due to the lack of basic infrastructure and/or trained operators. Paper-based diagnostic technologies are affordable, user-friendly, rapid, robust, and scalable for manufacturing, thus holding great potential to deliver point-of-care (POC) diagnostics to resource-limited settings. In this review, we present the working principles and reaction mechanism of paper-based diagnostics, including dipstick assays, lateral flow assays (LFAs), and microfluidic paper-based analytical devices (μPADs), as well as the selection of substrates and fabrication methods. Further, we report the advances in improving detection sensitivity, quantification readout, procedure simplification and multi-functionalization of paper-based diagnostics, and discuss the disadvantages of paper-based diagnostics. We envision that miniaturized and integrated paper-based diagnostic devices with the sample-in-answer-out capability will meet the diverse requirements for diagnosis and treatment monitoring at the POC.

  19. Diagnostic Coding for Epilepsy.

    PubMed

    Williams, Korwyn; Nuwer, Marc R; Buchhalter, Jeffrey R

    2016-02-01

    Accurate coding is an important function of neurologic practice. This contribution to Continuum is part of an ongoing series that presents helpful coding information along with examples related to the issue topic. Tips for diagnosis coding, Evaluation and Management coding, procedure coding, or a combination are presented, depending on which is most applicable to the subject area of the issue.

  20. [Over diagnostic imaging in cardiology].

    PubMed

    Carpeggiani, Clara

    2014-03-01

    Medical imaging is one of the major cause of rising health care costs. Diagnostic imaging has increased more rapidly than any other component of medical care. About 5 billion imaging tests are performed worldwide each year. According to recent estimates, at least one-third of all examinations are partially or totally inappropriate. Two out of 3 imaging tests employ ionizing radiations with radiology or nuclear medicine. The medical use of radiation is the largest man-made source of radiation exposure. Medical X-rays and γ-rays are a proven human carcinogen. The attributable long-term extra-risk of cancer due to diagnostic testing is around 10% in industrialized countries. Cardiologists prescribe and/or directly perform >50% of all imaging examinations, accounting for about two-thirds of the total effective dose given to patients. The dose of common cardiological examinations may be significant: 500 chest X-rays= a stress scintigraphy with sestamibi, 750 chest X-rays= a Multislice Computed Tomography, 1,000 chest X-rays= a coronary angiography and stenting. Unfortunately, few doctors are aware of the level of radiation their patients are exposed to during radiological tests and more intensive use of ionizing testing was not associated with greater awareness. Also as a consequence of unawareness, the rate of inappropriate examinations is unacceptably high in cardiology, even for procedures with high radiation load. Higher exposure doses correspond to higher long-term risks; there are no safe doses, and all doses add up in determining the cumulative risks over a lifetime. Doctors should make every effort so that «each patient should get the right imaging exam, at the right time, with the right radiation dose», as suggested by US Food and Drug Administration in the 2010 initiative to reduce unnecessary radiation exposure from medical imaging. This is best obtained through a systematic implementation of the "3 A's strategy" proposed by the International Atomic Energy

  1. [Safety of food additives in Japan].

    PubMed

    Ito, Sumio

    2011-01-01

    Recently, many accidents relating to food happened in Japan. The consumer's distrust for food, food companies, and the administration is increasing. The consumer especially has an extreme refusal feeling for chemicals such as food additives and agricultural chemicals, and begins to request agricultural chemical-free vegetables and food additive-free food. Food companies also state no agricultural chemicals and no food additives to correspond with consumers' request and aim at differentiating. The food additive is that the Ministry of Health, Labour and Welfare specifies the one that person's health might not be ruined by providing for Food Sanitation Law Article 10 in our country. The standard for food additives and standard for use of food additives are provided according to regulations of Food Sanitation Law Article 11. Therefore, it is thought that the food additive used is safe now. Then, it reports on the procedure and the safety examination, etc. in our country for designation for food additive this time.

  2. NIO1 diagnostics

    NASA Astrophysics Data System (ADS)

    Zaniol, B.; Barbisan, M.; Cavenago, M.; De Muri, M.; Mimo, A.; Pasqualotto, R.; Serianni, G.

    2015-04-01

    The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm2. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

  3. Laboratory Diagnostics of Botulism

    PubMed Central

    Lindström, Miia; Korkeala, Hannu

    2006-01-01

    Botulism is a potentially lethal paralytic disease caused by botulinum neurotoxin. Human pathogenic neurotoxins of types A, B, E, and F are produced by a diverse group of anaerobic spore-forming bacteria, including Clostridium botulinum groups I and II, Clostridium butyricum, and Clostridium baratii. The routine laboratory diagnostics of botulism is based on the detection of botulinum neurotoxin in the patient. Detection of toxin-producing clostridia in the patient and/or the vehicle confirms the diagnosis. The neurotoxin detection is based on the mouse lethality assay. Sensitive and rapid in vitro assays have been developed, but they have not yet been appropriately validated on clinical and food matrices. Culture methods for C. botulinum are poorly developed, and efficient isolation and identification tools are lacking. Molecular techniques targeted to the neurotoxin genes are ideal for the detection and identification of C. botulinum, but they do not detect biologically active neurotoxin and should not be used alone. Apart from rapid diagnosis, the laboratory diagnostics of botulism should aim at increasing our understanding of the epidemiology and prevention of the disease. Therefore, the toxin-producing organisms should be routinely isolated from the patient and the vehicle. The physiological group and genetic traits of the isolates should be determined. PMID:16614251

  4. NIO1 diagnostics

    SciTech Connect

    Zaniol, B. Barbisan, M.; Pasqualotto, R.; Serianni, G.; Cavenago, M.; De Muri, M.; Mimo, A.

    2015-04-08

    The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

  5. Thioaptamer Diagnostic System (TDS)

    NASA Technical Reports Server (NTRS)

    Yang, Xianbin

    2015-01-01

    AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

  6. Instrumentation and diagnostics

    SciTech Connect

    Nakaishi, C.V.; Bedick, R.C.

    1990-12-01

    This Technology Status Report describes research and accomplishments for the Instrumentation and Diagnostics (I D) Projects within the Advanced Research and Technology Development (AR TD) Program of the United States Department of Energy (DOE) Office of Fossil Energy (FE). Process understanding and control can be improved through the development of advanced instrumentation and diagnostics. The thrust of the I D Projects is to further develop existing measurement and control techniques for application to advanced coal-based technologies. Project highlights are: an inductively coupled plasma (ICP) instrument has been developed to analyze trace elements in gasification and combustion process streams. An in situ two-color Mie scattering technique with LSS can simultaneously measure the size, velocity, and elemental composition of coal particles during combustion. A high-temperature, fluorescence thermometry technique has accurately measured gas temperatures during field testing in combustion and gasification environments. Expert systems have been developed to improve the control of advanced coal-based processes. Capacitance flowmeters were developed to determine the mass flowrate, solid volume fraction, and particle velocities of coal slurries. 32 refs., 9 figs.

  7. Diagnostic Oligonucleotide Microarray Fingerprinting of Bacillus Isolates

    SciTech Connect

    Chandler, Darrell P.; Alferov, Oleg; Chernov, Boris; Daly, Don S.; Golova, Julia; Perov, Alexander N.; Protic, Miroslava; Robison, Richard; Shipma, Matthew; White, Amanda M.; Willse, Alan R.

    2006-01-01

    A diagnostic, genome-independent microbial fingerprinting method using DNA oligonucleotide microarrays was used for high-resolution differentiation between closely related Bacillus strains, including two strains of Bacillus anthracis that are monomorphic (indistinguishable) via amplified fragment length polymorphism fingerprinting techniques. Replicated hybridizations on 391-probe nonamer arrays were used to construct a prototype fingerprint library for quantitative comparisons. Descriptive analysis of the fingerprints, including phylogenetic reconstruction, is consistent with previous taxonomic organization of the genus. Newly developed statistical analysis methods were used to quantitatively compare and objectively confirm apparent differences in microarray fingerprints with the statistical rigor required for microbial forensics and clinical diagnostics. These data suggest that a relatively simple fingerprinting microarray and statistical analysis method can differentiate between species in the Bacillus cereus complex, and between strains of B. anthracis. A synthetic DNA standard was used to understand underlying microarray and process-level variability, leading to specific recommendations for the development of a standard operating procedure and/or continued technology enhancements for microbial forensics and diagnostics.

  8. Interventional MSK procedures: the hip

    PubMed Central

    Lefebvre, Guillaume; Cockenpot, Eric; Chastanet, Patrick; Cotten, Anne

    2016-01-01

    Percutaneous musculoskeletal procedures are widely accepted as low invasive, highly effective, efficient and safe methods in a vast amount of hip pathologies either in diagnostic or in therapeutic management. Hip intra-articular injections are used for the symptomatic treatment of osteoarthritis. Peritendinous or intrabursal corticosteroid injections can be used for the symptomatic treatment of greater trochanteric pain syndrome and anterior iliopsoas impingement. In past decades, the role of interventional radiology has rapidly increased in metastatic disease, thanks to the development of many ablative techniques. Image-guided percutaneous ablation of skeletal metastases provides a minimally invasive treatment option that appears to be a safe and effective palliative treatment for localized painful lytic lesion. Methods of tumour destruction based on temperature, such as radiofrequency ablation (RFA) and cryotherapy, are performed for the management of musculoskeletal metastases. MR-guided focused ultrasound surgery provides a non-invasive alternative to these ablative methods. Cementoplasty is now widely used for pain management and consolidation of acetabular metastases and can be combined with RFA. RFA is also used to treat benign tumours, namely osteoid osteomas. New interventional procedures such as percutaneous screw fixation are also proposed to treat non-displaced or minimally displaced acetabular roof fractures. PMID:26317896

  9. Evaluation and Interventional Management of Pain After Vertebral Augmentation Procedures

    PubMed Central

    Granville, Michelle; Jacobson, Robert E

    2017-01-01

     required blocks performed within the first six weeks after vertebral augmentation. In this case, the blocks included those at non-adjacent levels. A total of 4/12 cases (33%) had a block within 12 weeks of the original vertebral augmentation procedure. Lumbar spine imaging showed that at least 9/12 patients had pre-existing significant lumbar pathology at the time of fracture treatment. This may have contributed to the later development of pain. Conclusion Pain after a successful vertebral augmentation is typically non-acute (i.e., beyond six weeks). Mechanisms other than the primary VCF are usually responsible for non-adjacent level pain, which are present a majority of the time on reviewing the patients' diagnostic studies. These mechanisms usually take many weeks to develop and subsequently elicit pain that requires additional interventional pain procedures. In our study, the pain is usually related to the pre-existing degenerative spondylosis and stenosis rather than the fracture site. This study shows that the facet joints in closely related lumbar degenerative changes are the cause of pain in this patient group. These procedures should be explored with pain after vertebral augmentation, especially in those patients with known or suspected spinal degeneration and/or poor biomechanics.

  10. Polylactides in additive biomanufacturing.

    PubMed

    Poh, Patrina S P; Chhaya, Mohit P; Wunner, Felix M; De-Juan-Pardo, Elena M; Schilling, Arndt F; Schantz, Jan-Thorsten; van Griensven, Martijn; Hutmacher, Dietmar W

    2016-12-15

    New advanced manufacturing technologies under the alias of additive biomanufacturing allow the design and fabrication of a range of products from pre-operative models, cutting guides and medical devices to scaffolds. The process of printing in 3 dimensions of cells, extracellular matrix (ECM) and biomaterials (bioinks, powders, etc.) to generate in vitro and/or in vivo tissue analogue structures has been termed bioprinting. To further advance in additive biomanufacturing, there are many aspects that we can learn from the wider additive manufacturing (AM) industry, which have progressed tremendously since its introduction into the manufacturing sector. First, this review gives an overview of additive manufacturing and both industry and academia efforts in addressing specific challenges in the AM technologies to drive toward AM-enabled industrial revolution. After which, considerations of poly(lactides) as a biomaterial in additive biomanufacturing are discussed. Challenges in wider additive biomanufacturing field are discussed in terms of (a) biomaterials; (b) computer-aided design, engineering and manufacturing; (c) AM and additive biomanufacturing printers hardware; and (d) system integration. Finally, the outlook for additive biomanufacturing was discussed.

  11. Additive Manufactured Product Integrity

    NASA Technical Reports Server (NTRS)

    Waller, Jess; Wells, Doug; James, Steve; Nichols, Charles

    2017-01-01

    NASA is providing key leadership in an international effort linking NASA and non-NASA resources to speed adoption of additive manufacturing (AM) to meet NASA's mission goals. Participants include industry, NASA's space partners, other government agencies, standards organizations and academia. Nondestructive Evaluation (NDE) is identified as a universal need for all aspects of additive manufacturing.

  12. An overview of nuclear medicine imaging procedures.

    PubMed

    Hogg, Peter; Lawson, Richard

    2015-11-25

    Nuclear medicine imaging is not generally well understood by nurses who work outside this area. Consequently, nurses can find themselves unable to answer patients' questions about nuclear medicine imaging procedures or give them proper information before they attend for a test. This article aims to explain what is involved in some common diagnostic nuclear medicine imaging procedures so that nurses are able to discuss this with patients. It also addresses some common issues about radiation protection that nurses might encounter in their usual working routine. The article includes links to videos showing some typical nuclear medicine imaging procedures from a patient's point of view and links to an e-Learning for Healthcare online resource that provides detailed information for nurses.

  13. Aesthetic Surgical Crown Lengthening Procedure

    PubMed Central

    de Oliveira, Pablo Santos; Chiarelli, Fabio; Rodrigues, José A.; Shibli, Jamil A.; Zizzari, Vincenzo Luca; Piattelli, Adriano; Iezzi, Giovanna; Perrotti, Vittoria

    2015-01-01

    The aim of this case report was to describe the surgical sequence of crown lengthening to apically reposition the dentogingival complex, in addition to an esthetic restorative procedure. Many different causes can be responsible for short clinical crown. In these cases, the correct execution of a restorative or prosthetic rehabilitation requires an increasing of the crown length. According to the 2003 American Academy of Periodontology (Practice Profile Survey), crown lengthening is the most habitual surgical periodontal treatment. PMID:26609452

  14. 24 CFR 10.12 - Additional rulemaking proceedings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Additional rulemaking proceedings. 10.12 Section 10.12 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development RULEMAKING: POLICY AND PROCEDURES Procedures § 10.12 Additional rulemaking...

  15. Diagnostics for first plasma and development plan on KSTAR

    SciTech Connect

    Lee, J. H.; Na, H. K.; Lee, S. G.; Bak, J. G.; Seo, D. C.; Seo, S. H.; Oh, S. T.; Ko, W. H.; Chung, J.; Nam, Y. U.; Lee, K. D.; Ka, E. M.; Oh, Y. K.; Kwon, M.; Jeong, S. H.

    2010-06-15

    The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H{sub {alpha}}, visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

  16. Procedure: Ensuring EPA Public Content in the EPA Web Environment

    EPA Pesticide Factsheets

    This document outlines the procedures for ensuring access to EPA information by hosting EPA data and information on the epa.gov server. Additionally, it provides the procedures for obtaining waivers of this requirement.

  17. [Dealing with diagnostic uncertainty in general practice].

    PubMed

    Wübken, Magdalena; Oswald, Jana; Schneider, Antonius

    2013-01-01

    In general, the prevalence of diseases is low in primary care. Therefore, the positive predictive value of diagnostic tests is lower than in hospitals where patients are highly selected. In addition, the patients present with milder forms of disease; and many diseases might hide behind the initial symptom(s). These facts lead to diagnostic uncertainty which is somewhat inherent to general practice. This narrative review discusses different sources of and reasons for uncertainty and strategies to deal with it in the context of the current literature. Fear of uncertainty correlates with higher diagnostic activities. The attitude towards uncertainty correlates with the choice of medical speciality by vocational trainees or medical students. An intolerance of uncertainty, which still increases as medicine is making steady progress, might partly explain the growing shortage of general practitioners. The bio-psycho-social context appears to be important to diagnostic decision-making. The effect of intuition and heuristics are investigated by cognitive psychologists. It is still unclear whether these aspects are prone to bias or useful, which might depend on the context of medical decisions. Good communication is of great importance to share uncertainty with the patients in a transparent way and to alleviate shared decision-making. Dealing with uncertainty should be seen as an important core component of general practice and needs to be investigated in more detail to improve the respective medical decisions.

  18. Unique passive diagnostic for slapper detonators

    NASA Technical Reports Server (NTRS)

    Brigham, William P.; Schwartz, John J.

    1994-01-01

    The objective of this study was to find a material and configuration that could reliably detect the proper functioning of a slapper (non-explosive) detonator. Because of the small size of the slapper geometry (on the order of a 15 mils), most diagnostic techniques are not suitable. This program has the additional requirements that the device would be used on centrifuge so that it could not use any electrical power or output signals. This required that the diagnostic be completely passive. The paper describes the three facets of the development effort: complete characterization of the slapper using VISAR measurements, selection of the diagnostic material and configuration, and testing of the prototype designs. The VISAR testing required that use of a special optical probe to allow the laser light to reach both bridges of the dual-slapper detonator. Results are given in the form of flyer velocity as a function of the initiating charge voltage level. The selected diagnostic design functions in a manner similar to a dent block except that the impact of the Kapton disk from a properly-functioning slapper causes a fracture pattern. A quick visual inspection is all that is needed to determine if the flyer velocity exceeded the threshold value. Sub-threshold velocities produce a substantially different appearance.

  19. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Fletcher, James C. (Inventor); Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1992-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  20. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1993-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of the additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  1. Breast ductal endoscopy: how many procedures qualify?

    PubMed Central

    Zagouri, Flora; Sergentanis, Theodoros N; Giannakopoulou, Georgia; Panopoulou, Effrosyni; Chrysikos, Dimosthenis; Bletsa, Garifallia; Flessas, John; Filippakis, George; Papalabros, Alexandros; Bramis, Kostas J; Zografos, George C

    2009-01-01

    Background Breast ductal endoscopy is a relatively new diagnostic method with ever growing importance in the work-up of patients with bloody nipple discharge. The ability to perform ductal endoscopy is very important and useful for breast fellows. Learning curve in breast ductal endoscopy remains a terra incognita, since no systematic studies have addressed this topic. The purpose of this study is to determine the point (number of procedures during training) beyond which ductal endoscopy is successfully performed. Findings Ten breast fellows received training in our Breast Unit. For the training process, an ex vivo model was adopted. Fellows were trained on 20 surgical specimens derived from modified radical mastectomy for breast cancer. The target of the education program was to acquire proficiency in performing ductoscopy. The achievement of four consecutively successful ductal endoscopies was determined as the point beyond which proficiency had been achieved. The number of procedures needed for the achievement of proficiency as defined above ranged between 9 and 17 procedures. The median value was 13 procedures; i.e. 50% of trainees had achieved proficiency at the 13th procedure or earlier. Conclusion These pilot findings point to approximately 13 procedures as a point beyond which ductal endoscopy is successfully performed; studies on a larger number of fellows are nevertheless needed. Further research, focusing on the learning curves of different training models of ductal endoscopy, seems desirable. PMID:19566939

  2. Diagnostic strategies in osteomyelitis

    SciTech Connect

    Wheat, J.

    1985-06-28

    Technetium-/sup 99/ pyrophosphate bone scanning often identifies patients with osteomyelitis before roentgenographic findings appear. However, recent studies have shown that /sup 99/Tc bone scanning often gives false-negative results, especially in neonates. The accuracy of computed tomographic scanning and indium-111 leukocyte scanning for diagnosis of early osteomyelitis has not been established. /sup 99/Tc bone scanning often gives false-positive results in patients with other conditions leading to bone injury and repair, such as trauma or recent surgery, further limiting the usefulness of this imaging procedure. Newer imaging techniques have not been adequately evaluated to establish their specificity. Because of their high cost and unproved accuracy, these new imaging procedures should not be routinely applied until their usefulness has been established. Bone biopsy remains the procedure of choice for establishing the diagnosis in patients suspected clinically to have osteomyelitis with negative findings on roentgenography and /sup 99/Tc bone scanning. Although Staphylococcus aureus is the leading cause of osteomyelitis, other pathogens cause 30 to 40 percent of cases. Aspiration or biopsy of the involved bone is usually required to choose appropriate antibiotic therapy. Bone biopsy is essential in chronic osteomyelitis, since cultures of sinus drainage are unreliable. Osteomyelitis in diabetics with foot infection and in association with decubitus ulcers presents special problems. Radionuclide scanning often give false-positive results in these patients. Proper diagnosis usually requires careful assessment of clinical and roentgenographic findings. 33 references.

  3. [Bloody diarrhoea - causes, diagnostics and therapy].

    PubMed

    Heinrich, Henriette; Vavricka, Stephan R

    2014-09-01

    Bloody diarrhoea is always a warning sign and should prompt a more thorough history on duration and accompanying symptoms as well as current medications (antibiotics, NSAR) and diseases (HIV, IBD, transplant organ recipients). In this review the most common bacterial, viral and parasitical causes of bloody diarrhoea as well as radiation and ischemic colitis will be discussed. Additionally important diagnostic tools such as stool cultures and calprotectin for infectious causes auf diarrhoea and imaging tools (CT and endoscopy) for ischemic disease are presented. The causes of bloody diarroea in immunosuppressed patients and IBD are additionally addressed.

  4. Food Additives and Hyperkinesis

    ERIC Educational Resources Information Center

    Wender, Ester H.

    1977-01-01

    The hypothesis that food additives are causally associated with hyperkinesis and learning disabilities in children is reviewed, and available data are summarized. Available from: American Medical Association 535 North Dearborn Street Chicago, Illinois 60610. (JG)

  5. Smog control fuel additives

    SciTech Connect

    Lundby, W.

    1993-06-29

    A method is described of controlling, reducing or eliminating, ozone and related smog resulting from photochemical reactions between ozone and automotive or industrial gases comprising the addition of iodine or compounds of iodine to hydrocarbon-base fuels prior to or during combustion in an amount of about 1 part iodine per 240 to 10,000,000 parts fuel, by weight, to be accomplished by: (a) the addition of these inhibitors during or after the refining or manufacturing process of liquid fuels; (b) the production of these inhibitors for addition into fuel tanks, such as automotive or industrial tanks; or (c) the addition of these inhibitors into combustion chambers of equipment utilizing solid fuels for the purpose of reducing ozone.

  6. Rig Diagnostic Tools

    NASA Technical Reports Server (NTRS)

    Soileau, Kerry M.; Baicy, John W.

    2008-01-01

    Rig Diagnostic Tools is a suite of applications designed to allow an operator to monitor the status and health of complex networked systems using a unique interface between Java applications and UNIX scripts. The suite consists of Java applications, C scripts, Vx- Works applications, UNIX utilities, C programs, and configuration files. The UNIX scripts retrieve data from the system and write them to a certain set of files. The Java side monitors these files and presents the data in user-friendly formats for operators to use in making troubleshooting decisions. This design allows for rapid prototyping and expansion of higher-level displays without affecting the basic data-gathering applications. The suite is designed to be extensible, with the ability to add new system components in building block fashion without affecting existing system applications. This allows for monitoring of complex systems for which unplanned shutdown time comes at a prohibitive cost.

  7. Diagnostics and Microelectronics

    SciTech Connect

    Balch, J.W.

    1993-03-01

    This report discusses activities of the Diagnostics and Microelectronics thrust area which conducts activities in semiconductor devices and semiconductor fabrication technology for programs at Lawrence Livermore National Laboratory. Our multidisciplinary engineering and scientific staff use modern computational tools and semi-conductor microfabrication equipment to develop high-performance devices. Our work concentrates on three broad technologies of semiconductor microdevices: (1) silicon on III-V semiconductor microeletronics, (2) lithium niobate-based and III-V semiconductor-based photonics, and (3) silicon-based micromaching for application to microstructures and microinstruments. In FY-92, we worked on projects in seven areas, described in this report: novel photonic detectors; a wideband phase modulator; an optoelectronic terahertz beam system; the fabrication of microelectrode electrochemical sensors; diamond heatsinks; advanced micromachining technologies; and electrophoresis using silicon microchannels.

  8. Diagnostic paediatric imaging

    SciTech Connect

    Hall, C.M.; Lingam, S.

    1986-01-01

    This book is a case study teaching manual presenting radiographs and examples of other imaging modalities from 100 paediatric patients. The material comes from the radiological teaching collection at the Hospital for Sick Children at Great Ormond Street in London and was compiled over a ten year period. With each case a short clinical history is given and a series of questions posed, similar to those encountered in postgraduate medical examinations. Sample answers with comments and more illustrations are presented on the following page. The last decade has seen a rapid expansion in the range and sophistication of diagnostic imaging modalities which are available to clinicians. Since it is impossible to achieve comprehensive coverage in a book of this size, the authors have selected examples of cases which illustrate the range of imaging modalities currently available and which may be encountered in both clinical practice and in examinations.

  9. Alpha-particle diagnostics

    SciTech Connect

    Young, K.M.

    1991-01-01

    This paper will focus on the state of development of diagnostics which are expected to provide the information needed for {alpha}- physics studies in the future. Conventional measurement of detailed temporal and spatial profiles of background plasma properties in DT will be essential for such aspects as determining heating effectiveness, shaping of the plasma profiles and effects of MHD, but will not be addressed here. This paper will address (1) the measurement of the neutron source, and hence {alpha}-particle birth profile, (2) measurement of the escaping {alpha}-particles and (3) measurement of the confined {alpha}-particles over their full energy range. There will also be a brief discussion of (4) the concerns about instabilities being generated by {alpha}-particles and the methods necessary for measuring these effects. 51 refs., 10 figs.

  10. Diagnostic Evaluation of Rhabdomyolysis

    PubMed Central

    Nance, Jessica R.; Mammen, Andrew L.

    2015-01-01

    Rhabdomyolysis is characterized by severe acute muscle injury resulting in muscle pain, weakness, and/or swelling with release of myofiber contents into the bloodstream. Symptoms develop over hours to days following an inciting factor and may be associated with dark pigmentation of the urine. Serum creatine kinase and urine myoglobin levels are markedly elevated. The clinical examination, history, laboratory studies, muscle biopsy, and genetic testing are useful tools for diagnosis of rhabdomyolysis, and they can help differentiate acquired from inherited causes of rhabdomyolysis. Acquired causes include substance abuse, medication or toxic exposures, electrolyte abnormalities, endocrine disturbance, and autoimmune myopathies. Inherited predisposition to rhabdomyolysis can occur with disorders of glycogen metabolism, fatty acid beta-oxidation, and mitochondrial oxidative phosphorylation. Less common inherited causes of rhabdomyolysis include structural myopathies, channelopathies, and sickle cell disease. This review focuses on the differentiation of acquired and inherited causes of rhabdomyolysis and proposes a practical diagnostic algorithm. PMID:25678154

  11. Identification of factors associated with diagnostic error in primary care

    PubMed Central

    2014-01-01

    Background Missed, delayed or incorrect diagnoses are considered to be diagnostic errors. The aim of this paper is to describe the methodology of a study to analyse cognitive aspects of the process by which primary care (PC) physicians diagnose dyspnoea. It examines the possible links between the use of heuristics, suboptimal cognitive acts and diagnostic errors, using Reason’s taxonomy of human error (slips, lapses, mistakes and violations). The influence of situational factors (professional experience, perceived overwork and fatigue) is also analysed. Methods Cohort study of new episodes of dyspnoea in patients receiving care from family physicians and residents at PC centres in Granada (Spain). With an initial expected diagnostic error rate of 20%, and a sampling error of 3%, 384 episodes of dyspnoea are calculated to be required. In addition to filling out the electronic medical record of the patients attended, each physician fills out 2 specially designed questionnaires about the diagnostic process performed in each case of dyspnoea. The first questionnaire includes questions on the physician’s initial diagnostic impression, the 3 most likely diagnoses (in order of likelihood), and the diagnosis reached after the initial medical history and physical examination. It also includes items on the physicians’ perceived overwork and fatigue during patient care. The second questionnaire records the confirmed diagnosis once it is reached. The complete diagnostic process is peer-reviewed to identify and classify the diagnostic errors. The possible use of heuristics of representativeness, availability, and anchoring and adjustment in each diagnostic process is also analysed. Each audit is reviewed with the physician responsible for the diagnostic process. Finally, logistic regression models are used to determine if there are differences in the diagnostic error variables based on the heuristics identified. Discussion This work sets out a new approach to studying the

  12. 10 CFR 781.53 - Additional licenses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Additional licenses. 781.53 Section 781.53 Energy DEPARTMENT OF ENERGY DOE PATENT LICENSING REGULATIONS Types of Licenses and Conditions for Licensing § 781.53... Energy Organization Act or other law. Procedures...

  13. 10 CFR 781.53 - Additional licenses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Additional licenses. 781.53 Section 781.53 Energy DEPARTMENT OF ENERGY DOE PATENT LICENSING REGULATIONS Types of Licenses and Conditions for Licensing § 781.53... Energy Organization Act or other law. Procedures...

  14. 10 CFR 781.53 - Additional licenses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Additional licenses. 781.53 Section 781.53 Energy DEPARTMENT OF ENERGY DOE PATENT LICENSING REGULATIONS Types of Licenses and Conditions for Licensing § 781.53... Energy Organization Act or other law. Procedures...

  15. Dental indications for the instrumental functional analysis in additional consideration of health-economic aspects

    PubMed Central

    Tinnemann, Peter; Stöber, Yvonne; Roll, Stephanie; Vauth, Christoph; Willich, Stefan N.; Greiner, Wolfgang

    2010-01-01

    Background Besides clinical and radiological examination instrumental functional analyses are performed as diagnostic procedures for craniomandibular dysfunctions. Instrumental functional analyses cause substantial costs and shows a considerable variability between individual dentist practices. Objectives On the basis of published scientific evidence the validity of the instrumental functional analysis for the diagnosis of craniomandibular dysfunctions compared to clinical diagnostic procedures; the difference of the various forms of the instrumental functional analysis; the existence of a dependency on additional other factors and the need for further research are determined in this report. In addition, the cost effectiveness of the instrumental functional analysis is analysed in a health-policy context, and social, legal and ethical aspects are considered. Methods A literature search is performed in over 27 databases and by hand. Relevant companies and institutions are contacted concerning unpublished studies. The inclusion criteria for publications are (i) diagnostic studies with the indication “craniomandibular malfunction”, (ii) a comparison between clinical and instrumental functional analysis, (iii) publications since 1990, (iv) publications in English or German. The identified literature is evaluated by two scientists regarding the relevance of content and methodical quality. Results The systematic database search resulted in 962 hits. 187 medical and economic complete publications are evaluated. Since the evaluated studies are not relevant enough to answer the medical or health economic questions no study is included. Discussion The inconsistent terminology concerning craniomandibular dysfunctions and instrumental functional analyses results in a broad literature search in databases and an extensive search by hand. Since no relevant results concerning the validity of the instrumental functional analysis in comparison to the clinical functional analysis

  16. Patient dose monitoring in Dubai in radiography and interventional procedures.

    PubMed

    AlSuwaidi, J S; AlMazrouei, N K; Pottybindu, S; Siraj, M; Mathew, D; Al Blooshi, A A; Kuriakose, V P

    2015-06-01

    This paper presents ongoing actions in Dubai on patient dose monitoring in digital radiographic examinations, mammography, interventional procedures, and dental radiological procedures. The aim of Dubai Health Authority (DHA) is to move towards the establishment of local diagnostic reference levels. DHA has participated in national and regional projects under the umbrella of the International Atomic Energy Agency. The need for local radiation protection educational programmes and wider patient dosimetry monitoring and recording emerged from this work.

  17. Pyroshock prediction procedures

    NASA Astrophysics Data System (ADS)

    Piersol, Allan G.

    2002-05-01

    Given sufficient effort, pyroshock loads can be predicted by direct analytical procedures using Hydrocodes that analytically model the details of the pyrotechnic explosion and its interaction with adjacent structures, including nonlinear effects. However, it is more common to predict pyroshock environments using empirical procedures based upon extensive studies of past pyroshock data. Various empirical pyroshock prediction procedures are discussed, including those developed by the Jet Propulsion Laboratory, Lockheed-Martin, and Boeing.

  18. Candidate CDTI procedures study

    NASA Technical Reports Server (NTRS)

    Ace, R. E.

    1981-01-01

    A concept with potential for increasing airspace capacity by involving the pilot in the separation control loop is discussed. Some candidate options are presented. Both enroute and terminal area procedures are considered and, in many cases, a technologically advanced Air Traffic Control structure is assumed. Minimum display characteristics recommended for each of the described procedures are presented. Recommended sequencing of the operational testing of each of the candidate procedures is presented.

  19. Diagnostic of fusion neutrons on JET tokamak using diamond detector

    SciTech Connect

    Nemtsev, G.; Amosov, V.; Marchenko, N.; Meshchaninov, S.; Rodionov, R.; Popovichev, S.; Collaboration: JET EFDA Conbributors

    2014-08-21

    In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

  20. [Prospects of endoscopic technology for diagnostics of inflammatory periodontal disease].

    PubMed

    Orekhova, L Yu; Neizberg, D M; Demchenko, T V; Artem'ev, N A; Loboda, E S

    The aim of the study was to analyze research methods for periodontitis severity and elaborate the most effective diagnostic combination. Twenty patients with moderate periodontal disease were included in the study. In addition to conventional diagnostic methods depth of periodontal pockets (PP) was measured by means of endoscopic system and cone bean CT. Differences in PP depth estimated by probing and endoscopic evaluation was 1.2±0.4 mm proving endoscopic method to be useful and most precise tool for periodontal diagnostics.

  1. Diagnostic Imaging of Dental Disease in Pet Rabbits and Rodents.

    PubMed

    Capello, Vittorio

    2016-09-01

    Diagnostic imaging techniques are of paramount importance for dentistry and oral disorders of rabbits, rodents, and other exotic companion mammals. Aside from standard radiography, stomatoscopy is a complementary tool allowing a thorough and detailed inspection of the oral cavity. Computed tomography (CT) generates multiple 2-dimensional views and 3-dimensional reconstructions providing superior diagnostic accuracy also useful for prognosis and treatment of advanced dental disease and its related complications. MRI is a diagnostic imaging technique additional to CT used primarily to enhance soft tissues, including complex odontogenic abscesses.

  2. Modified arthroscopic Brostrom procedure.

    PubMed

    Lui, Tun Hing

    2015-09-01

    The open modified Brostrom anatomic repair technique is widely accepted as the reference standard for lateral ankle stabilization. However, there is high incidence of intra-articular pathologies associated with chronic lateral ankle instability which may not be addressed by an isolated open Brostrom procedure. Arthroscopic Brostrom procedure with suture anchor has been described for anatomic repair of chronic lateral ankle instability and management of intra-articular lesions. However, the complication rates seemed to be higher than open Brostrom procedure. Modification of the arthroscopic Brostrom procedure with the use of bone tunnel may reduce the risk of certain complications.

  3. Progress of development of Thomson scattering diagnostic system on COMPASS.

    PubMed

    Bilkova, P; Melich, R; Aftanas, M; Böhm, P; Sestak, D; Jares, D; Weinzettl, V; Stöckel, J; Hron, M; Panek, R; Scannell, R; Walsh, M J

    2010-10-01

    A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

  4. Group Sparse Additive Models

    PubMed Central

    Yin, Junming; Chen, Xi; Xing, Eric P.

    2016-01-01

    We consider the problem of sparse variable selection in nonparametric additive models, with the prior knowledge of the structure among the covariates to encourage those variables within a group to be selected jointly. Previous works either study the group sparsity in the parametric setting (e.g., group lasso), or address the problem in the nonparametric setting without exploiting the structural information (e.g., sparse additive models). In this paper, we present a new method, called group sparse additive models (GroupSpAM), which can handle group sparsity in additive models. We generalize the ℓ1/ℓ2 norm to Hilbert spaces as the sparsity-inducing penalty in GroupSpAM. Moreover, we derive a novel thresholding condition for identifying the functional sparsity at the group level, and propose an efficient block coordinate descent algorithm for constructing the estimate. We demonstrate by simulation that GroupSpAM substantially outperforms the competing methods in terms of support recovery and prediction accuracy in additive models, and also conduct a comparative experiment on a real breast cancer dataset.

  5. Additive Manufacturing Infrared Inspection

    NASA Technical Reports Server (NTRS)

    Gaddy, Darrell

    2014-01-01

    Additive manufacturing is a rapid prototyping technology that allows parts to be built in a series of thin layers from plastic, ceramics, and metallics. Metallic additive manufacturing is an emerging form of rapid prototyping that allows complex structures to be built using various metallic powders. Significant time and cost savings have also been observed using the metallic additive manufacturing compared with traditional techniques. Development of the metallic additive manufacturing technology has advanced significantly over the last decade, although many of the techniques to inspect parts made from these processes have not advanced significantly or have limitations. Several external geometry inspection techniques exist such as Coordinate Measurement Machines (CMM), Laser Scanners, Structured Light Scanning Systems, or even traditional calipers and gages. All of the aforementioned techniques are limited to external geometry and contours or must use a contact probe to inspect limited internal dimensions. This presentation will document the development of a process for real-time dimensional inspection technique and digital quality record of the additive manufacturing process using Infrared camera imaging and processing techniques.

  6. Quantitation of intracranial aneurysm neck size from diagnostic angiograms based on a biomathematical model.

    PubMed

    Hademenos, G J; Massoud, T F; Viñuela, F

    1995-10-01

    Accurate measurement of the aneurysm neck size from diagnostic angiograms is crucial in the consideration and implementation of interventional embolotherapeutic procedures. Due to inherent problems in angiography, aneurysm morphology and location, and obstruction by overlying structures, accurate measurement of the aneurysm neck size is difficult. We are proposing a method for the angiographic measurement of aneurysm neck size based on a biomathematical model of an aneurysm. A biomathematical model of an intracranial saccular aneurysm was developed based on Laplace's law for a spherical elastic object, given by: Stress = Pressure x Radius/2 x Wall thickness. In addition, another biomechanical parameter used to describe an elastic sphere is the strain: Strain = delta R/Ri = (R-Ri)/Ri where R is the current aneurysm radius and Ri is the initial radius prior to aneurysm development. The stress and strain of an elastic structure are used to describe the elastic modulus, E: E = stress/strain = [PR/2h]/[(R-Ri)/Ri] = [PRRi]/[2hR-2hri]. It is assumed at this point that no additional tissue growth occurs through the developmental course of the aneurysm. The expression for E is now solved for Ri which, in essence, represents the radius of the aneurysm neck: Ri = [2hER]/[PR + 2hE]. Thus, the diameter of the neck, Dn, is given by Dn = 2 + i = 2 ([2hER]/[PR + 2hE]). During diagnostic angiography, the radius, R, and pressure, P, are easily obtained during the examination procedure. However, it is not possible to angiographically determine the elastic modulus, E, and the wall thickness, h. In this case, the following average values are used: E = 1.0 MPa and h = 50 microns. From the diagnostic angiograms and hospital records of 23 patients, the aneurysm neck size was determined using the biomathematical model and compared to the results obtained from the correlative relationship between the measured and accepted ratios of neck size to diameter of parent artery. The neck diameter

  7. Phenylethynyl Containing Reactive Additives

    NASA Technical Reports Server (NTRS)

    Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor)

    2002-01-01

    Phenylethynyl containing reactive additives were prepared from aromatic diamine, containing phenylethvnvl groups and various ratios of phthalic anhydride and 4-phenylethynviphthalic anhydride in glacial acetic acid to form the imide in one step or in N-methyl-2-pvrrolidinone to form the amide acid intermediate. The reactive additives were mixed in various amounts (10% to 90%) with oligomers containing either terminal or pendent phenylethynyl groups (or both) to reduce the melt viscosity and thereby enhance processability. Upon thermal cure, the additives react and become chemically incorporated into the matrix and effect an increase in crosslink density relative to that of the host resin. This resultant increase in crosslink density has advantageous consequences on the cured resin properties such as higher glass transition temperature and higher modulus as compared to that of the host resin.

  8. Fused Lasso Additive Model

    PubMed Central

    Petersen, Ashley; Witten, Daniela; Simon, Noah

    2016-01-01

    We consider the problem of predicting an outcome variable using p covariates that are measured on n independent observations, in a setting in which additive, flexible, and interpretable fits are desired. We propose the fused lasso additive model (FLAM), in which each additive function is estimated to be piecewise constant with a small number of adaptively-chosen knots. FLAM is the solution to a convex optimization problem, for which a simple algorithm with guaranteed convergence to a global optimum is provided. FLAM is shown to be consistent in high dimensions, and an unbiased estimator of its degrees of freedom is proposed. We evaluate the performance of FLAM in a simulation study and on two data sets. Supplemental materials are available online, and the R package flam is available on CRAN. PMID:28239246

  9. Phenylethynyl Containing Reactive Additives

    NASA Technical Reports Server (NTRS)

    Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor)

    2002-01-01

    Phenylethynyl containing reactive additives were prepared from aromatic diamines containing phenylethynyl groups and various ratios of phthalic anhydride and 4-phenylethynylphthalic anhydride in glacial acetic acid to form the imide in one step or in N-methyl-2-pyrrolidi none to form the amide acid intermediate. The reactive additives were mixed in various amounts (10% to 90%) with oligomers containing either terminal or pendent phenylethynyl groups (or both) to reduce the melt viscosity and thereby enhance processability. Upon thermal cure, the additives react and become chemically incorporated into the matrix and effect an increase in crosslink density relative to that of the host resin. This resultant increase in crosslink density has advantageous consequences on the cured resin properties such as higher glass transition temperature and higher modulus as compared to that of the host resin.

  10. Piezo-sensor self-diagnostics using electrical impedance measurements.

    SciTech Connect

    Park, G. H.; Farrar, C. R.; Rutherford, A. C.; Robertson, A. N.

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  11. Additives in plastics.

    PubMed Central

    Deanin, R D

    1975-01-01

    The polymers used in plastics are generally harmless. However, they are rarely used in pure form. In almost all commercial plastics, they are "compounded" with monomeric ingredients to improve their processing and end-use performance. In order of total volume used, these monomeric additives may be classified as follows: reinforcing fibers, fillers, and coupling agents; plasticizers; colorants; stabilizers (halogen stabilizers, antioxidants, ultraviolet absorbers, and biological preservatives); processing aids (lubricants, others, and flow controls); flame retardants, peroxides; and antistats. Some information is already available, and much more is needed, on potential toxicity and safe handling of these additives during processing and manufacture of plastics products. PMID:1175566

  12. Additives in plastics.

    PubMed

    Deanin, R D

    1975-06-01

    The polymers used in plastics are generally harmless. However, they are rarely used in pure form. In almost all commercial plastics, they are "compounded" with monomeric ingredients to improve their processing and end-use performance. In order of total volume used, these monomeric additives may be classified as follows: reinforcing fibers, fillers, and coupling agents; plasticizers; colorants; stabilizers (halogen stabilizers, antioxidants, ultraviolet absorbers, and biological preservatives); processing aids (lubricants, others, and flow controls); flame retardants, peroxides; and antistats. Some information is already available, and much more is needed, on potential toxicity and safe handling of these additives during processing and manufacture of plastics products.

  13. Endoscopic ultrasound guided interventional procedures

    PubMed Central

    Sharma, Vishal; Rana, Surinder S; Bhasin, Deepak K

    2015-01-01

    Endoscopic ultrasound (EUS) has emerged as an important diagnostic and therapeutic modality in the field of gastrointestinal endoscopy. EUS provides access to many organs and lesions which are in proximity to the gastrointestinal tract and thus giving an opportunity to target them for therapeutic and diagnostic purposes. This modality also provides a real time opportunity to target the required area while avoiding adjacent vascular and other structures. Therapeutic EUS has found role in management of pancreatic fluid collections, biliary and pancreatic duct drainage in cases of failed endoscopic retrograde cholangiopancreatography, drainage of gallbladder, celiac plexus neurolysis/blockage, drainage of mediastinal and intra-abdominal abscesses and collections and in targeted cancer chemotherapy and radiotherapy. Infact, therapeutic EUS has emerged as the therapy of choice for management of pancreatic pseudocysts and recent innovations like fully covered removable metallic stents have improved results in patients with organised necrosis. Similarly, EUS guided drainage of biliary tract and pancreatic duct helps drainage of these systems in patients with failed cannulation, inaccessible papilla as with duodenal/gastric obstruction or surgically altered anatomy. EUS guided gall bladder drainage is a useful emergent procedure in patients with acute cholecystitis who are not fit for surgery. EUS guided celiac plexus neurolysis and blockage is more effective and less morbid vis-à-vis the percutaneous technique. The field of interventional EUS is rapidly advancing and many more interventions are being continuously added. This review focuses on the current status of evidence vis-à-vis the established indications of therapeutic EUS. PMID:26078831

  14. Antiphospholipid syndrome: A diagnostic challenge.

    PubMed

    Mallhi, R S; Kushwaha, Neerja; Chatterjee, T; Philip, J

    2016-12-01

    The antiphospholipid syndrome (APS) is an acquired autoimmune thrombophilic disorder that is characterized by thrombosis (venous, arterial and microvascular) and obstetric morbidity due to a diverse family of antibodies against phospholipid-binding proteins present in plasma. The term antiphospholipid antibody is actually a misnomer as the antibodies are not against the phospholipid per se, but target the plasma protein co-factors, which bind to anionic PLs. The exact etiology has not been elucidated and is multifactorial. The initial guidelines for the diagnosis of APS were laid down in Sapporo, 1999, which were subsequently revised as the Sydney Consensus Conference criteria in 2006. Major changes were the inclusion of β2GPI as independent laboratory criteria, addition of ischemic stroke and transient cerebral ischemia as established clinical criteria and the requirement of repeating the test after 12 weeks. The laboratory tests recommended are coagulation assays, which study the effect of lupus anticoagulant on the clotting time and immunological assays, mostly ELISAs to detect IgG and IgM antibodies against cardiolipin and/or β2 glycoprotein I. For the diagnosis of APS, at least one clinical criterion and one laboratory criterion should be present. Limitations pertaining to the standardization, reproducibility and robustness of the currently recommended diagnostic tests still remain. Despite elaborate guidelines and syndrome defining criteria, the diagnosis of APS still remains a challenge. A greater interaction between the clinicians and the laboratory professionals is necessary for arriving at the correct diagnosis as a misdiagnosis of APS can have grave consequences.

  15. Spectroscopic diagnostics of dusty plasmas

    NASA Astrophysics Data System (ADS)

    Ouaras, Karim

    2014-10-01

    The formation of carbon nanoparticles particles in low pressure magnetized hydrocarbon plasmas is investigated using infrared quantum cascade laser absorption spectroscopy (QCLAS), mass spectrometry (MS) and laser extinction spectroscopy (LES). Results showed that dust formation is correlated to the presence of a large amount of large positively charged hydrocarbon ions. Large negative ions or neutral species were not observed. These results, along with a qualitative comparison of diffusion and reaction characteristic, suggest that a positive ion may contribute to the growth of nanoparticles in hydrocarbon magnetized plasmas. Growth of carbon nanoparticles has been widely studied in RF plasma. Our aim is to complete these studies in different discharge system, in which the growth mechanisms may be different. In particular, we focus our work on dipolar ECR microwave discharge. The magnetic field of the plasma source is likely to trap carbon-containing charged particles and then modify the dust growth kinetics. In the present study the combination of these diagnostics gives us the tools to study the kinetics of plasma processes. In this way both qualitative and quantitative characteristics could be obtained. An outstanding role may be attributed to the positive ions in the monitored magnetized plasmas, whereas usually formation of dust is supposed driven by negative ions. In addition, we focus our work in tungsten nanoparticle in particular with LES, this noninvasive technique provide us the tool to follow the dynamics and concentration dust. K. Ouaras, L. Colina Delacqua, G. Lombardi, K. Hassouni, and X. Bonnin.

  16. Student Interpretations of Diagnostic Feedback

    ERIC Educational Resources Information Center

    Doe, Christine

    2015-01-01

    Diagnostic assessment is increasingly being recognized as a potentially beneficial tool for teaching and learning (Jang, 2012). There have been calls in the research literature for students to receive diagnostic feedback and for researchers to investigate how such feedback is used by students. Therefore, this study examined how students…

  17. Dual Processing and Diagnostic Errors

    ERIC Educational Resources Information Center

    Norman, Geoff

    2009-01-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical,…

  18. Motor neurone disease: diagnostic pitfalls.

    PubMed

    Williams, Timothy L

    2013-02-01

    The misdiagnosis of MND (particularly of the ALS phenotype), is uncommon. Atypical presentations, particularly of focal onset and with pure LMN or UMN signs, present a more difficult diagnostic challenge, although perhaps reassuringly, treatable mimics are rare. A working knowledge of potential alternative conditions and MND diagnostic pitfalls should help to reduce the misdiagnosis rate, particularly if the key points are considered.

  19. Ellipsoidal reflectors in biomedical diagnostic

    NASA Astrophysics Data System (ADS)

    Bezuglyi, M. A.; Bezuglaya, N. V.

    2013-11-01

    In this work were considered photometric tools for biomedical diagnostics, which contain a mirror ellipsoid of revolution. Proposed schemes with ellipsoidal reflectors for diagnostics in reflected and in reflected and transmitted light. A comparative analysis of measurement standards scattering surfaces was held.

  20. Status of US ITER Diagnostics

    NASA Astrophysics Data System (ADS)

    Stratton, B.; Delgado-Aparicio, L.; Hill, K.; Johnson, D.; Pablant, N.; Barnsley, R.; Bertschinger, G.; de Bock, M. F. M.; Reichle, R.; Udintsev, V. S.; Watts, C.; Austin, M.; Phillips, P.; Beiersdorfer, P.; Biewer, T. M.; Hanson, G.; Klepper, C. C.; Carlstrom, T.; van Zeeland, M. A.; Brower, D.; Doyle, E.; Peebles, A.; Ellis, R.; Levinton, F.; Yuh, H.

    2013-10-01

    The US is providing 7 diagnostics to ITER: the Upper Visible/IR cameras, the Low Field Side Reflectometer, the Motional Stark Effect diagnostic, the Electron Cyclotron Emission diagnostic, the Toroidal Interferometer/Polarimeter, the Core Imaging X-Ray Spectrometer, and the Diagnostic Residual Gas Analyzer. The front-end components of these systems must operate with high reliability in conditions of long pulse operation, high neutron and gamma fluxes, very high neutron fluence, significant neutron heating (up to 7 MW/m3) , large radiant and charge exchange heat flux (0.35 MW/m2) , and high electromagnetic loads. Opportunities for repair and maintenance of these components will be limited. These conditions lead to significant challenges for the design of the diagnostics. Space constraints, provision of adequate radiation shielding, and development of repair and maintenance strategies are challenges for diagnostic integration into the port plugs that also affect diagnostic design. The current status of design of the US ITER diagnostics is presented and R&D needs are identified. Supported by DOE contracts DE-AC02-09CH11466 (PPPL) and DE-AC05-00OR22725 (UT-Battelle, LLC).

  1. Automated diagnostic kiosk for diagnosing diseases

    DOEpatents

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  2. Extensive phlegmon and pyoderma gangrenosum: diagnostic difficulties

    PubMed Central

    Wcisło-Dziadecka, Dominika; Brzezińska-Wcisło, Ligia; Arasiewicz, Hubert

    2015-01-01

    Pyoderma gangrenosum (PG) is a relatively rare neutrophilic dermatosis, characterized by progressive skin necrosis. It typically has a chronic course, of unknown etiology. Pyoderma gangrenosum diagnosis can be difficult because both histopathological examination and results of additional laboratory tests are not specific and the clinical state is conclusive, as for other physicians it poses a number of diagnostic dilemmas. Therefore, this condition should be treated interdisciplinary. We present a case of a 40-year-old patient with a diagnosis of PG, which in the early stages of the disease was treated as an extensive phlegmon by physicians of other specialties and it presented a serious diagnostic as well as therapeutic problem. PMID:25821427

  3. [Advances in the diagnostics of Alzheimer's disease].

    PubMed

    Fiedler, U; Wiltfang, J; Peters, N; Benninghoff, J

    2012-05-01

    Due to the demographic developments, diagnosis and treatment, dementia constitutes an increasing medical challenge and is likely to have an increasing socioeconomic impact. Dementia does not reflect a single disease but encompasses a variety of underlying conditions, heterogeneous clinical courses and therapeutic approaches, among which Alzheimer's disease represents the most common cause. Therefore, a thorough differential diagnosis of dementia is of major importance. To date the current diagnosis of dementia according to ICD-10/DMS-IV is based on clinical criteria. In addition, the concept of mild cognitive impairment comprises early cognitive dysfunction without clinically apparent dementia. Alzheimer's disease is more and more conceptualized as a disease continuum with mild cognitive impairment as an early and manifest dementia as the later stage of the disease. This review gives an overview on the current diagnostic approaches and the proposed revisions of diagnostic and research criteria for Alzheimer's disease.

  4. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  5. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  6. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  7. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions. 410.32 Section 410.32 Public Health CENTERS FOR MEDICARE... (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic...

  8. Biobased lubricant additives

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Fully biobased lubricants are those formulated using all biobased ingredients, i.e. biobased base oils and biobased additives. Such formulations provide the maximum environmental, safety, and economic benefits expected from a biobased product. Currently, there are a number of biobased base oils that...

  9. More Than Additional Space...

    ERIC Educational Resources Information Center

    CEFP Journal, 1973

    1973-01-01

    A much needed addition to the Jamestown Elementary School turned out to be more than an expansion of walls for more space. A new educational program, a limited budget, and a short time line were tackled on a team approach basis and were successfully resolved. (Author)

  10. Surgical procedures in pinniped and cetacean species.

    PubMed

    Higgins, Jennifer L; Hendrickson, Dean A

    2013-12-01

    Significant advances in veterinary diagnostic and surgical techniques have been made over the past several decades. Many of these advances, however, have not reached the field of marine mammal medicine. A number of limitations exist: risks of anesthesia, anatomical challenges, difficulties with wound closure, environmental constraints, equipment limitations, and perceived risks. Despite these limitations, surgical treatments have been successfully utilized in marine mammals. While surgery is performed in pinnipeds more frequently than in cetaceans, studies conducted in the 1960s and 1970s on dolphin sleep and hearing demonstrated that general anesthesia can be successfully induced in cetaceans. Since this pioneering work, a small number of successful surgeries have been performed in dolphins under both general anesthesia and heavy sedation. While these surgical procedures in pinnipeds and cetaceans have typically been limited to wound management, dentistry, ophthalmic procedures, fracture repair, and superficial biopsy, a number of abdominal surgeries have also been performed. Recently there have been pioneering successes in the application of minimally invasive surgery in marine mammals. Many of the anatomical challenges that almost prohibit traditional laparotomies in cetacean species and present challenges in pinnipeds can be overcome through the use of laparoscopic techniques. Due to the limited number of pinnipeds and cetaceans in captivity and, thus, the limited case load for veterinarians serving marine mammal species, it is vital for knowledge of surgical procedures to be shared among those in the field. This paper reviews case reports of surgical procedures, both traditional and laparoscopic, in pinnipeds and cetaceans. Limitations to performing surgical procedures in marine mammals are discussed and surgical case reports analyzed in an effort to determine challenges that must be overcome in order to make surgery a more feasible diagnostic and treatment

  11. Procedural Learning and Dyslexia

    ERIC Educational Resources Information Center

    Nicolson, R. I.; Fawcett, A. J.; Brookes, R. L.; Needle, J.

    2010-01-01

    Three major "neural systems", specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed ("Trends Neurosci.",30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief…

  12. Enucleation Procedure Manual.

    ERIC Educational Resources Information Center

    Davis, Kevin; Poston, George

    This manual provides information on the enucleation procedure (removal of the eyes for organ banks). An introductory section focuses on the anatomy of the eye and defines each of the parts. Diagrams of the eye are provided. A list of enucleation materials follows. Other sections present outlines of (1) a sterile procedure; (2) preparation for eye…

  13. Connectionist Learning Procedures.

    ERIC Educational Resources Information Center

    Hinton, Geoffrey E.

    A major goal of research on networks of neuron-like processing units is to discover efficient learning procedures that allow these networks to construct complex internal representations of their environment. The learning procedures must be capable of modifying the connection strengths in such a way that internal units which are not part of the…

  14. Diagnostics for emission-control-system malfunction on three-way catalyst-equipped vehicles. Final report, November 1983-November 1985

    SciTech Connect

    Duleep, K.G.

    1985-11-01

    The report presents the results of a two part study. In Phase I, the contractor reviewed current manufacturer recommended diagnostic procedures for identifying vehicular emission control malfunctions on three-way catalyst-equipped gasoline-fueled automobiles and also surveyed diagnostic techniques used in the field. Diagnosis of malperformance was limited to the following systems: exhaust gas recirculating, secondary air, fuel, and catalyst. In Phase II, the contractor developed generalized diagnostic procedures for malfunctioning emission control systems and validated these procedures on 52 vehicles. Two mechanics alternatively disabled and repaired the vehicles using the diagnostic and repair procedures. The report also describes inspection procedures developed for the control of smoke emissions from light-duty diesel vehicles. Two types of procedures were developed, for component testing and for inspection/maintenance programs. These procedures were validated on six light-duty vehicles.

  15. Verification of Loop Diagnostics

    NASA Technical Reports Server (NTRS)

    Winebarger, A.; Lionello, R.; Mok, Y.; Linker, J.; Mikic, Z.

    2014-01-01

    Many different techniques have been used to characterize the plasma in the solar corona: density-sensitive spectral line ratios are used to infer the density, the evolution of coronal structures in different passbands is used to infer the temperature evolution, and the simultaneous intensities measured in multiple passbands are used to determine the emission measure. All these analysis techniques assume that the intensity of the structures can be isolated through background subtraction. In this paper, we use simulated observations from a 3D hydrodynamic simulation of a coronal active region to verify these diagnostics. The density and temperature from the simulation are used to generate images in several passbands and spectral lines. We identify loop structures in the simulated images and calculate the loop background. We then determine the density, temperature and emission measure distribution as a function of time from the observations and compare with the true temperature and density of the loop. We find that the overall characteristics of the temperature, density, and emission measure are recovered by the analysis methods, but the details of the true temperature and density are not. For instance, the emission measure curves calculated from the simulated observations are much broader than the true emission measure distribution, though the average temperature evolution is similar. These differences are due, in part, to inadequate background subtraction, but also indicate a limitation of the analysis methods.

  16. [Diagnostic imaging of lying].

    PubMed

    Lass, Piotr; Sławek, Jarosław; Sitek, Emilia; Szurowska, Edyta; Zimmermann, Agnieszka

    2013-01-01

    Functional diagnostic imaging has been applied in neuropsychology for more than two decades. Nowadays, the functional magnetic resonance (fMRI) seems to be the most important technique. Brain imaging in lying has been performed and discussed since 2001. There are postulates to use fMRI for forensic purposes, as well as commercially, e.g. testing the loyalty of employees, especially because of the limitations of traditional polygraph in some cases. In USA fMRI is performed in truthfulness/lying assessment by at least two commercial companies. Those applications are a matter of heated debate of practitioners, lawyers and specialists of ethics. The opponents of fMRI use for forensic purposes indicate the lack of common agreement on it and the lack of wide recognition and insufficient standardisation. Therefore it cannot serve as a forensic proof, yet. However, considering the development of MRI and a high failure rate of traditional polygraphy, forensic applications of MRI seem to be highly probable in future.

  17. ISM Diagnostics: Dust

    NASA Astrophysics Data System (ADS)

    Onaka, Takashi

    2013-03-01

    Infrared (IR) observations provide significant information on the lifecycle of dust grains in the interstellar medium (ISM), which is crucial for the understanding of the evolution of matter in the universe. The IR spectral energy distribution (SED) of the dust emission tells us the relative abundance of sub-micron grains, very small grains, and carriers of the unidentified infrared (UIR) emission bands, since they emit the far-IR, the mid-IR, and the UIR bands from the near- to mid-IR, respectively. On the other hand, the UIR emission bands themselves offer a useful means to probe the physical conditions from which the band emission arises because each band is assigned to a specific C-H or C-C vibration mode and because its relative intensity should reflect the properties of the band carriers and the physical conditions of the environment. Here the two diagnostic methods using IR observations are briefly described together with examples of the observational results. Implications for the dust lifecycle are also discussed.

  18. The tissue diagnostic instrument

    NASA Astrophysics Data System (ADS)

    Hansma, Paul; Yu, Hongmei; Schultz, David; Rodriguez, Azucena; Yurtsev, Eugene A.; Orr, Jessica; Tang, Simon; Miller, Jon; Wallace, Joseph; Zok, Frank; Li, Cheng; Souza, Richard; Proctor, Alexander; Brimer, Davis; Nogues-Solan, Xavier; Mellbovsky, Leonardo; Peña, M. Jesus; Diez-Ferrer, Oriol; Mathews, Phillip; Randall, Connor; Kuo, Alfred; Chen, Carol; Peters, Mathilde; Kohn, David; Buckley, Jenni; Li, Xiaojuan; Pruitt, Lisa; Diez-Perez, Adolfo; Alliston, Tamara; Weaver, Valerie; Lotz, Jeffrey

    2009-05-01

    Tissue mechanical properties reflect extracellular matrix composition and organization, and as such, their changes can be a signature of disease. Examples of such diseases include intervertebral disk degeneration, cancer, atherosclerosis, osteoarthritis, osteoporosis, and tooth decay. Here we introduce the tissue diagnostic instrument (TDI), a device designed to probe the mechanical properties of normal and diseased soft and hard tissues not only in the laboratory but also in patients. The TDI can distinguish between the nucleus and the annulus of spinal disks, between young and degenerated cartilage, and between normal and cancerous mammary glands. It can quantify the elastic modulus and hardness of the wet dentin left in a cavity after excavation. It can perform an indentation test of bone tissue, quantifying the indentation depth increase and other mechanical parameters. With local anesthesia and disposable, sterile, probe assemblies, there has been neither pain nor complications in tests on patients. We anticipate that this unique device will facilitate research on many tissue systems in living organisms, including plants, leading to new insights into disease mechanisms and methods for their early detection.

  19. Diagnostic of Horndeski theories

    NASA Astrophysics Data System (ADS)

    Perenon, Louis; Marinoni, Christian; Piazza, Federico

    2017-01-01

    We study the effects of Horndeski models of dark energy on the observables of the large-scale structure in the late time universe. A novel classification into Late dark energy, Early dark energy and Early modified gravity scenarios is proposed, according to whether such models predict deviations from the standard paradigm persistent at early time in the matter domination epoch. We discuss the physical imprints left by each specific class of models on the effective Newton constant μ, the gravitational slip parameter η, the light deflection parameter Σ and the growth function fσ8 and demonstrate that a convenient way to dress a complete portrait of the viability of the Horndeski accelerating mechanism is via two, redshift-dependent, diagnostics: the μ(z) ‑ Σ(z) and the fσ8(z) ‑ Σ(z) planes. If future, model-independent, measurements point to either Σ ‑ 1 < 0 at redshift zero or μ ‑ 1 < 0 with Σ ‑ 1 > 0 at high redshifts or μ ‑ 1 > 0 with Σ ‑ 1 < 0 at high redshifts, Horndeski theories are effectively ruled out. If fσ8 is measured to be larger than expected in a ΛCDM model at z > 1.5 then Early dark energy models are definitely ruled out. On the opposite case, Late dark energy models are rejected by data if Σ < 1, while, if Σ > 1, only Early modifications of gravity provide a viable framework to interpret data.

  20. Magnetic Diagnostics in LDX

    NASA Astrophysics Data System (ADS)

    Karim, Ishtak; Kesner, Jay; Garnier, Darren; Mauel, Mike

    2001-10-01

    The Levitated Dipole Experiment (LDX) will investigate the stability and equilibrium of a high-beta plasma confined in a dipolar magnetic field. One of the principal goals of the experiment is to understand the effect of the plasma pressure profile on its global stability. We describe our plan to characterize the pressure profile by iteratively fitting solutions of the Grad-Shafranov equation to the magnetic inputs obtained from various magnetic sensors. Equilibrium fields will be measured using coils and loops placed outside the vacuum vessel. A poloidal array of pairs of orthogonally oriented B_p-coils will be placed at nine positions, and ten poloidal flux loops will be placed at optimal locations. Hall probes will be placed outside of the vessel to supplement the coil measurements. A toroidal array of Mirnov coils will be installed inside the vessel to measure fast (MHz) plasma oscillations caused by instability and to deduce their mode numbers. A detailed design of the proposed diagnostics and the current progress on their construction will be presented. Calibration test results of the B_p-coils will also be given. A general overview of the reconstruction algorithm will be shown.