Sample records for additional dose assessment

  1. TESTING FOR ADDITIVITY IN THE LOW DOSE REGION OF AN ENVIRONMENTALLY RELEVANT MIXTURE OF 18 OLYHALOGENATED AROMATIC HYDROCARBONS.

    EPA Science Inventory

    A common default assumption in risk assessment of chemical mixtures is that the chemicals combine additively in the low dose region. Under additivity, with information from single chemical dose-response data, the risk associated with the mixture can be estimated. The objective ...

  2. "The Dose Makes the Poison": Informing Consumers About the Scientific Risk Assessment of Food Additives.

    PubMed

    Bearth, Angela; Cousin, Marie-Eve; Siegrist, Michael

    2016-01-01

    Intensive risk assessment is required before the approval of food additives. During this process, based on the toxicological principle of "the dose makes the poison,ˮ maximum usage doses are assessed. However, most consumers are not aware of these efforts to ensure the safety of food additives and are therefore sceptical, even though food additives bring certain benefits to consumers. This study investigated the effect of a short video, which explains the scientific risk assessment and regulation of food additives, on consumers' perceptions and acceptance of food additives. The primary goal of this study was to inform consumers and enable them to construct their own risk-benefit assessment and make informed decisions about food additives. The secondary goal was to investigate whether people have different perceptions of food additives of artificial (i.e., aspartame) or natural origin (i.e., steviolglycoside). To attain these research goals, an online experiment was conducted on 185 Swiss consumers. Participants were randomly assigned to either the experimental group, which was shown a video about the scientific risk assessment of food additives, or the control group, which was shown a video about a topic irrelevant to the study. After watching the video, the respondents knew significantly more, expressed more positive thoughts and feelings, had less risk perception, and more acceptance than prior to watching the video. Thus, it appears that informing consumers about complex food safety topics, such as the scientific risk assessment of food additives, is possible, and using a carefully developed information video is a successful strategy for informing consumers. © 2015 Society for Risk Analysis.

  3. Applying Emax model and bivariate thin plate splines to assess drug interactions

    PubMed Central

    Kong, Maiying; Lee, J. Jack

    2014-01-01

    We review the semiparametric approach previously proposed by Kong and Lee and extend it to a case in which the dose-effect curves follow the Emax model instead of the median effect equation. When the maximum effects for the investigated drugs are different, we provide a procedure to obtain the additive effect based on the Loewe additivity model. Then, we apply a bivariate thin plate spline approach to estimate the effect beyond additivity along with its 95% point-wise confidence interval as well as its 95% simultaneous confidence interval for any combination dose. Thus, synergy, additivity, and antagonism can be identified. The advantages of the method are that it provides an overall assessment of the combination effect on the entire two-dimensional dose space spanned by the experimental doses, and it enables us to identify complex patterns of drug interaction in combination studies. In addition, this approach is robust to outliers. To illustrate this procedure, we analyzed data from two case studies. PMID:20036878

  4. Applying Emax model and bivariate thin plate splines to assess drug interactions.

    PubMed

    Kong, Maiying; Lee, J Jack

    2010-01-01

    We review the semiparametric approach previously proposed by Kong and Lee and extend it to a case in which the dose-effect curves follow the Emax model instead of the median effect equation. When the maximum effects for the investigated drugs are different, we provide a procedure to obtain the additive effect based on the Loewe additivity model. Then, we apply a bivariate thin plate spline approach to estimate the effect beyond additivity along with its 95 per cent point-wise confidence interval as well as its 95 per cent simultaneous confidence interval for any combination dose. Thus, synergy, additivity, and antagonism can be identified. The advantages of the method are that it provides an overall assessment of the combination effect on the entire two-dimensional dose space spanned by the experimental doses, and it enables us to identify complex patterns of drug interaction in combination studies. In addition, this approach is robust to outliers. To illustrate this procedure, we analyzed data from two case studies.

  5. Detection and original dose assessment of egg powders subjected to gamma irradiation by using ESR technique

    NASA Astrophysics Data System (ADS)

    Aydın, Talat

    2015-09-01

    ESR (electron spin resonance) techniques were applied for detection and original dose estimation to radiation-processed egg powders. The un-irradiated (control) egg powders showed a single resonance line centered at g=2.0086±0.0005, 2.0081±0.0005, 2.0082±0.0005 (native signal) for yolk, white and whole egg, respectively. Irradiation induced at least one additional intense singlet overlapping to the control signal and caused a significant increase in signal intensity without any changes in spectral patterns. Responses of egg powders to different gamma radiation doses in the range 0-10 kGy were examined. The stability of the radiation-induced ESR signal of irradiated egg powders were investigated over a storage period of about 5 months. Additive reirradiation of the egg powders produces a reproducible dose response function, which can be used to assess the initial dose by back-extrapolation. The additive dose method gives an estimation of the original dose within ±12% at the end of the 720 h storage period.

  6. Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program.

    PubMed

    Zelefsky, Michael J; Cohen, Gilad N; Taggar, Amandeep S; Kollmeier, Marisa; McBride, Sean; Mageras, Gig; Zaider, Marco

    Our purpose was to describe the process and outcome of performing postimplantation dosimetric assessment and intraoperative dose correction during prostate brachytherapy using a novel image fusion-based treatment-planning program. Twenty-six consecutive patients underwent intraoperative real-time corrections of their dose distributions at the end of their permanent seed interstitial procedures. After intraoperatively planned seeds were implanted and while the patient remained in the lithotomy position, a cone beam computed tomography scan was obtained to assess adequacy of the prescription dose coverage. The implanted seed positions were automatically segmented from the cone-beam images, fused onto a new set of acquired ultrasound images, reimported into the planning system, and recontoured. Dose distributions were recalculated based upon actual implanted seed coordinates and recontoured ultrasound images and were reviewed. If any dose deficiencies within the prostate target were identified, additional needles and seeds were added. Once an implant was deemed acceptable, the procedure was completed, and anesthesia was reversed. When the intraoperative ultrasound-based quality assurance assessment was performed after seed placement, the median volume receiving 100% of the dose (V100) was 93% (range, 74% to 98%). Before seed correction, 23% (6/26) of cases were noted to have V100 <90%. Based on this intraoperative assessment and replanning, additional seeds were placed into dose-deficient regions within the target to improve target dose distributions. Postcorrection, the median V100 was 97% (range, 93% to 99%). Following intraoperative dose corrections, all implants achieved V100 >90%. In these patients, postimplantation evaluation during the actual prostate seed implant procedure was successfully applied to determine the need for additional seeds to correct dose deficiencies before anesthesia reversal. When applied, this approach should significantly reduce intraoperative errors and chances for suboptimal dose delivery during prostate brachytherapy. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  7. Cumulative effects of antiandrogenic chemical mixtures and their relevance to human health risk assessment.

    PubMed

    Howdeshell, Kembra L; Hotchkiss, Andrew K; Gray, L Earl

    2017-03-01

    Toxicological studies of defined chemical mixtures assist human health risk assessment by establishing how chemicals interact with one another to induce an effect. This paper reviews how antiandrogenic chemical mixtures can alter reproductive tract development in rats with a focus on the reproductive toxicant phthalates. The reviewed studies compare observed mixture data to mathematical mixture model predictions based on dose addition or response addition to determine how the individual chemicals in a mixture interact (e.g., additive, greater, or less than additive). Phthalate mixtures were observed to act in a dose additive manner based on the relative potency of the individual phthalates to suppress fetal testosterone production. Similar dose additive effects have been reported for mixtures of phthalates with antiandrogenic pesticides of differing mechanisms of action. Overall, data from these phthalate experiments in rats can be used in conjunction with human biomonitoring data to determine individual hazard indices, and recent cumulative risk assessments in humans indicate an excess risk to antiandrogenic chemical mixtures that include phthalates only or phthalates in combination with other antiandrogenic chemicals. Published by Elsevier GmbH.

  8. Advances in Chemical Mixtures Risk Methods

    EPA Science Inventory

    This presentation is an overview of emerging issues for dose addition in chemical mixtures risk assessment. It is intended to give the participants a perspective of recent developments in methods for dose addition. The workshop abstract is as follows:This problems-based, half-day...

  9. A Four Step Approach to Evaluate Mixtures for Consistency with Dose Addition

    EPA Science Inventory

    We developed a four step approach for evaluating chemical mixture data for consistency with dose addition for use in environmental health risk assessment. Following the concepts in the U.S. EPA mixture risk guidance (EPA 2000a,b), toxicological interaction for a defined mixture (...

  10. Dose estimates for the solid waste performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rittman, P.D.

    1994-08-30

    The Solid Waste Performance Assessment calculations by PNL in 1990 were redone to incorporate changes in methods and parameters since then. The ten scenarios found in their report were reduced to three, the Post-Drilling Resident, the Post-Excavation Resident, and an All Pathways Irrigator. In addition, estimates of population dose to people along the Columbia River are also included. The attached report describes the methods and parameters used in the calculations, and derives dose factors for each scenario. In addition, waste concentrations, ground water concentrations, and river water concentrations needed to reach the performance objectives of 100 mrem/yr and 500 person-rem/yrmore » are computed. Internal dose factors from DOE-0071 were applied when computing internal dose. External dose rate factors came from the GENII Version 1.485 software package. Dose calculations were carried out on a spreadsheet. The calculations are described in detail in the report for 63 nuclides, including 5 not presently in the GENII libraries. The spreadsheet calculations were checked by comparison with GENII, as described in Appendix D.« less

  11. A Web-Based System for Bayesian Benchmark Dose Estimation.

    PubMed

    Shao, Kan; Shapiro, Andrew J

    2018-01-11

    Benchmark dose (BMD) modeling is an important step in human health risk assessment and is used as the default approach to identify the point of departure for risk assessment. A probabilistic framework for dose-response assessment has been proposed and advocated by various institutions and organizations; therefore, a reliable tool is needed to provide distributional estimates for BMD and other important quantities in dose-response assessment. We developed an online system for Bayesian BMD (BBMD) estimation and compared results from this software with U.S. Environmental Protection Agency's (EPA's) Benchmark Dose Software (BMDS). The system is built on a Bayesian framework featuring the application of Markov chain Monte Carlo (MCMC) sampling for model parameter estimation and BMD calculation, which makes the BBMD system fundamentally different from the currently prevailing BMD software packages. In addition to estimating the traditional BMDs for dichotomous and continuous data, the developed system is also capable of computing model-averaged BMD estimates. A total of 518 dichotomous and 108 continuous data sets extracted from the U.S. EPA's Integrated Risk Information System (IRIS) database (and similar databases) were used as testing data to compare the estimates from the BBMD and BMDS programs. The results suggest that the BBMD system may outperform the BMDS program in a number of aspects, including fewer failed BMD and BMDL calculations and estimates. The BBMD system is a useful alternative tool for estimating BMD with additional functionalities for BMD analysis based on most recent research. Most importantly, the BBMD has the potential to incorporate prior information to make dose-response modeling more reliable and can provide distributional estimates for important quantities in dose-response assessment, which greatly facilitates the current trend for probabilistic risk assessment. https://doi.org/10.1289/EHP1289.

  12. Assessment of diurnal systemic dose of agrochemicals in regulatory toxicity testing--an integrated approach without additional animal use.

    PubMed

    Saghir, Shakil A; Bartels, Michael J; Rick, David L; McCoy, Alene T; Rasoulpour, Reza J; Ellis-Hutchings, Robert G; Sue Marty, M; Terry, Claire; Bailey, Jason P; Billington, Richard; Bus, James S

    2012-07-01

    Integrated toxicokinetics (TK) data provide information on the rate, extent and duration of systemic exposure across doses, species, strains, gender, and life stages within a toxicology program. While routine for pharmaceuticals, TK assessments of non-pharmaceuticals are still relatively rare, and have never before been included in a full range of guideline studies for a new agrochemical. In order to better understand the relationship between diurnal systemic dose (AUC(24h)) and toxicity of agrochemicals, TK analyses in the study animals is now included in all short- (excluding acute), medium- and long-term guideline mammalian toxicity studies including reproduction/developmental tests. This paper describes a detailed procedure for the implementation of TK in short-, medium- and long-term regulatory toxicity studies, without the use of satellite animals, conducted on three agrochemicals (X11422208, 2,4-D and X574175). In these studies, kinetically-derived maximum doses (KMD) from short-term studies instead of, or along with, maximum tolerated doses (MTD) were used for the selection of the high dose in subsequent longer-term studies. In addition to leveraging TK data to guide dose level selection, the integrated program was also used to select the most appropriate method of oral administration (i.e., gavage versus dietary) of test materials for rat and rabbit developmental toxicity studies. The integrated TK data obtained across toxicity studies (without the use of additional/satellite animals) provided data critical to understanding differences in response across doses, species, strains, sexes, and life stages. Such data should also be useful in mode of action studies and to improve human risk assessments. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    PubMed

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. THE EFFECTS OF AN ORGANOPHOSPHATE (OP)-CARBAMATE (CB) PESTICIDE MIXTURE ON CORE TEMPERATURE AND MOTOR ACTIVITY IN THE RAT.

    EPA Science Inventory

    Pesticide risk assessment has traditionally been based on the toxicological response to single agents. Dose-additivity has been the default in risk assessment evaluations of pesticides with a common mechanism of action, but there could be supra-additive or infra-additive inter...

  15. A framework for the use of single-chemical transcriptomics data in predicting the hazards associated with complex mixtures of polycyclic aromatic hydrocarbons.

    PubMed

    Labib, Sarah; Williams, Andrew; Kuo, Byron; Yauk, Carole L; White, Paul A; Halappanavar, Sabina

    2017-07-01

    The assumption of additivity applied in the risk assessment of environmental mixtures containing carcinogenic polycyclic aromatic hydrocarbons (PAHs) was investigated using transcriptomics. MutaTMMouse were gavaged for 28 days with three doses of eight individual PAHs, two defined mixtures of PAHs, or coal tar, an environmentally ubiquitous complex mixture of PAHs. Microarrays were used to identify differentially expressed genes (DEGs) in lung tissue collected 3 days post-exposure. Cancer-related pathways perturbed by the individual or mixtures of PAHs were identified, and dose-response modeling of the DEGs was conducted to calculate gene/pathway benchmark doses (BMDs). Individual PAH-induced pathway perturbations (the median gene expression changes for all genes in a pathway relative to controls) and pathway BMDs were applied to models of additivity [i.e., concentration addition (CA), generalized concentration addition (GCA), and independent action (IA)] to generate predicted pathway-specific dose-response curves for each PAH mixture. The predicted and observed pathway dose-response curves were compared to assess the sensitivity of different additivity models. Transcriptomics-based additivity calculation showed that IA accurately predicted the pathway perturbations induced by all mixtures of PAHs. CA did not support the additivity assumption for the defined mixtures; however, GCA improved the CA predictions. Moreover, pathway BMDs derived for coal tar were comparable to BMDs derived from previously published coal tar-induced mouse lung tumor incidence data. These results suggest that in the absence of tumor incidence data, individual chemical-induced transcriptomics changes associated with cancer can be used to investigate the assumption of additivity and to predict the carcinogenic potential of a mixture.

  16. Review of reconstruction of radiation incident air kerma by measurement of absorbed dose in tooth enamel with EPR.

    PubMed

    Wieser, A

    2012-03-01

    Electron paramagnetic resonance dosimetry with tooth enamel has been proved to be a reliable method to determine retrospectively exposures from photon fields with minimal detectable doses of 100 mGy or lower, which is lower than achievable with cytogenetic dose reconstruction methods. For risk assessment or validating dosimetry systems for specific radiation incidents, the relevant dose from the incident has to be calculated from the total absorbed dose in enamel by subtracting additional dose contributions from the radionuclide content in teeth, natural external background radiation and medical exposures. For calculating organ doses or evaluating dosimetry systems the absorbed dose in enamel from a radiation incident has to be converted to air kerma using dose conversion factors depending on the photon energy spectrum and geometry of the exposure scenario. This paper outlines the approach to assess individual dose contributions to absorbed dose in enamel and calculate individual air kerma of a radiation incident from the absorbed dose in tooth enamel.

  17. Evidence for dose-additive effects of pyrethroids on motor activity in rats.

    PubMed

    Wolansky, Marcelo J; Gennings, Chris; DeVito, Michael J; Crofton, Kevin M

    2009-10-01

    Pyrethroids are neurotoxic insecticides used in a variety of indoor and outdoor applications. Previous research characterized the acute dose-effect functions for 11 pyrethroids administered orally in corn oil (1 mL/kg) based on assessment of motor activity. We used a mixture of these 11 pyrethroids and the same testing paradigm used in single-compound assays to test the hypothesis that cumulative neurotoxic effects of pyrethroid mixtures can be predicted using the default dose-addition theory. Mixing ratios of the 11 pyrethroids in the tested mixture were based on the ED30 (effective dose that produces a 30% decrease in response) of the individual chemical (i.e., the mixture comprised equipotent amounts of each pyrethroid). The highest concentration of each individual chemical in the mixture was less than the threshold for inducing behavioral effects. Adult male rats received acute oral exposure to corn oil (control) or dilutions of the stock mixture solution. The mixture of 11 pyrethroids was administered either simultaneously (2 hr before testing) or after a sequence based on times of peak effect for the individual chemicals (4, 2, and 1 hr before testing). A threshold additivity model was fit to the single-chemical data to predict the theoretical dose-effect relationship for the mixture under the assumption of dose additivity. When subthreshold doses of individual chemicals were combined in the mixtures, we found significant dose-related decreases in motor activity. Further, we found no departure from the predicted dose-additive curve regardless of the mixture dosing protocol used. In this article we present the first in vivo evidence on pyrethroid cumulative effects supporting the default assumption of dose addition.

  18. Assessment of intake and internal dose from iodine-131 for exposed workers handling radiopharmaceutical products.

    PubMed

    Bitar, A; Maghrabi, M; Doubal, A W

    2013-12-01

    Two methods for determination of internal dose due to (131)I intake during the preparation and handling of iodine radiopharmaceutical products have been compared. The first method was based on the measurement of (131)I in 24-hour urine samples while the second method was based on the measurement in vivo of (131)I in thyroid. The results have shown that urine analysis method can be used as a screening test but not for internal dose assessment of exposed workers. Thyroid monitoring method was found to be more reliable and accurate method for assessing internal dose from (131)I intake. In addition, the assessed internal dose showed that the annual internal effective dose for some workers was below 1 mSv with no risk classification, whereas the results of other group of workers were between 1 and 6 mSv with low risk classification. Only one worker reached 7.66 mSv with high risk classification; and this worker must be monitored individually. © 2013 Elsevier Ltd. All rights reserved.

  19. Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems.

    PubMed

    Bacher, Klaus; Smeets, Peter; Vereecken, Ludo; De Hauwere, An; Duyck, Philippe; De Man, Robert; Verstraete, Koenraad; Thierens, Hubert

    2006-09-01

    The aim of this study was to compare the image quality and radiation dose in chest imaging using an amorphous silicon flat-panel detector system and an amorphous selenium flat-panel detector system. In addition, the low-contrast performance of both systems with standard and low radiation doses was compared. In two groups of 100 patients each, digital chest radiographs were acquired with either an amorphous silicon or an amorphous selenium flat-panel system. The effective dose of the examination was measured using thermoluminescent dosimeters placed in an anthropomorphic Rando phantom. The image quality of the digital chest radiographs was assessed by five experienced radiologists using the European Guidelines on Quality Criteria for Diagnostic Radiographic Images. In addition, a contrast-detail phantom study was set up to assess the low-contrast performance of both systems at different radiation dose levels. Differences between the two groups were tested for significance using the two-tailed Mann-Whitney test. The amorphous silicon flat-panel system allowed an important and significant reduction in effective dose in comparison with the amorphous selenium flat-panel system (p < 0.0001) for both the posteroanterior and lateral views. In addition, clinical image quality analysis showed that the dose reduction was not detrimental to image quality. Compared with the amorphous selenium flat-panel detector system, the amorphous silicon flat-panel detector system performed significantly better in the low-contrast phantom study, with phantom entrance dose values of up to 135 muGy. Chest radiographs can be acquired with a significantly lower patient radiation dose using an amorphous silicon flat-panel system than using an amorphous selenium flat-panel system, thereby producing images that are equal or even superior in quality to those of the amorphous selenium flat-panel detector system.

  20. Dose accumulation of multiple high dose rate prostate brachytherapy treatments in two commercially available image registration systems.

    PubMed

    Poder, Joel; Yuen, Johnson; Howie, Andrew; Bece, Andrej; Bucci, Joseph

    2017-11-01

    The purpose of this study was to assess whether deformable image registration (DIR) is required for dose accumulation of multiple high dose rate prostate brachytherapy (HDRPBT) plans treated with the same catheter pattern on two different CT datasets. DIR was applied to 20 HDRPBT patients' planning CT images who received two treatment fractions on sequential days, on two different CT datasets, with the same implant. Quality of DIR in Velocity and MIM image registration systems was assessed by calculating the Dice Similarity Coefficient (DSC) and mean distance to agreement (MDA) for the prostate, urethra and rectum contours. Accumulated doses from each system were then calculated using the same DIR technique and dose volume histogram (DVH) parameters compared to manual addition with no DIR. The average DSC was found to be 0.83 (Velocity) and 0.84 (MIM), 0.80 (Velocity) and 0.80 (MIM), 0.80 (Velocity) and 0.81 (MIM), for the prostate, rectum and urethra contours, respectively. The average difference in calculated DVH parameters between the two systems using dose accumulation was less than 1%, and there was no statistically significant difference found between deformably accumulated doses in the two systems versus manual DVH addition with no DIR. Contour propagation using DIR in velocity and MIM was shown to be at least equivalent to inter-observer contouring variability on CT. The results also indicate that dose accumulation through manual addition of DVH parameters may be sufficient for HDRPBT treatments treated with the same catheter pattern on two different CT datasets. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  1. Margin estimation and disturbances of irradiation field in layer-stacking carbon-ion beams for respiratory moving targets.

    PubMed

    Tajiri, Shinya; Tashiro, Mutsumi; Mizukami, Tomohiro; Tsukishima, Chihiro; Torikoshi, Masami; Kanai, Tatsuaki

    2017-11-01

    Carbon-ion therapy by layer-stacking irradiation for static targets has been practised in clinical treatments. In order to apply this technique to a moving target, disturbances of carbon-ion dose distributions due to respiratory motion have been studied based on the measurement using a respiratory motion phantom, and the margin estimation given by the square root of the summation Internal margin2+Setup margin2 has been assessed. We assessed the volume in which the variation in the ratio of the dose for a target moving due to respiration relative to the dose for a static target was within 5%. The margins were insufficient for use with layer-stacking irradiation of a moving target, and an additional margin was required. The lateral movement of a target converts to the range variation, as the thickness of the range compensator changes with the movement of the target. Although the additional margin changes according to the shape of the ridge filter, dose uniformity of 5% can be achieved for a spherical target 93 mm in diameter when the upward range variation is limited to 5 mm and the additional margin of 2.5 mm is applied in case of our ridge filter. Dose uniformity in a clinical target largely depends on the shape of the mini-peak as well as on the bolus shape. We have shown the relationship between range variation and dose uniformity. In actual therapy, the upper limit of target movement should be considered by assessing the bolus shape. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  2. Evidence for Dose-Additive Effects of Pyrethroids on Motor Activity in Rats

    EPA Science Inventory

    BACKGROUND: Pyrethroids are neurotoxic insecticides used in a variety of indoor and outdoor applications. Previous research characterized the acute dose-effect functions for 11 pyrethroids administered orally in corn oil (1 mL/kg) based on assessment of motor activity. OBJECTIVES...

  3. Combined exposure to low doses of pesticides causes decreased birth weights in rats.

    PubMed

    Hass, Ulla; Christiansen, Sofie; Axelstad, Marta; Scholze, Martin; Boberg, Julie

    2017-09-01

    Decreased birth weight is a common effect of many pesticides in reproductive toxicity studies, but there are no empirical data on how pesticides act in combination on this endpoint. We hypothesized that a mixture of six pesticides (cyromazine, MCPB, pirimicarb, quinoclamine, thiram, and ziram) would decrease birth weight, and that these mixture effects could be predicted by the Dose Addition model. Data for the predictions were obtained from the Draft Assessment Reports of the individual pesticides. A mixture of equi-effective doses of these pesticides was tested in two studies in Wistar rats, showing mixture effects in good agreement with the additivity predictions. Significantly lower birth weights were observed when compounds were present at individual doses below their no-observed adverse effect levels (NOAELs). These results emphasize the need for cumulative risk assessment of pesticides to avoid potentially serious impact of mixed exposure on prenatal development and pregnancy in humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Modeling Rabbit Responses to Single and Multiple Aerosol ...

    EPA Pesticide Factsheets

    Journal Article Survival models are developed here to predict response and time-to-response for mortality in rabbits following exposures to single or multiple aerosol doses of Bacillus anthracis spores. Hazard function models were developed for a multiple dose dataset to predict the probability of death through specifying dose-response functions and the time between exposure and the time-to-death (TTD). Among the models developed, the best-fitting survival model (baseline model) has an exponential dose-response model with a Weibull TTD distribution. Alternative models assessed employ different underlying dose-response functions and use the assumption that, in a multiple dose scenario, earlier doses affect the hazard functions of each subsequent dose. In addition, published mechanistic models are analyzed and compared with models developed in this paper. None of the alternative models that were assessed provided a statistically significant improvement in fit over the baseline model. The general approach utilizes simple empirical data analysis to develop parsimonious models with limited reliance on mechanistic assumptions. The baseline model predicts TTDs consistent with reported results from three independent high-dose rabbit datasets. More accurate survival models depend upon future development of dose-response datasets specifically designed to assess potential multiple dose effects on response and time-to-response. The process used in this paper to dev

  5. Relationship between Individual External Doses, Ambient Dose Rates and Individuals' Activity-Patterns in Affected Areas in Fukushima following the Fukushima Daiichi Nuclear Power Plant Accident.

    PubMed

    Naito, Wataru; Uesaka, Motoki; Yamada, Chie; Kurosawa, Tadahiro; Yasutaka, Tetsuo; Ishii, Hideki

    2016-01-01

    The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses and the corresponding airborne monitoring-based ambient doses and time-activity patterns of individuals. Moreover, the results provide important information for predicting future cumulative doses after the return of residents to evacuation order areas in Fukushima.

  6. Relationship between Individual External Doses, Ambient Dose Rates and Individuals’ Activity-Patterns in Affected Areas in Fukushima following the Fukushima Daiichi Nuclear Power Plant Accident

    PubMed Central

    Kurosawa, Tadahiro; Yasutaka, Tetsuo; Ishii, Hideki

    2016-01-01

    The accident at Fukushima Daiichi Nuclear Power Plant on March 11, 2011, released radioactive material into the atmosphere and contaminated the land in Fukushima and several neighboring prefectures. Five years after the nuclear disaster, the radiation levels have greatly decreased due to physical decay, weathering, and decontamination operations in Fukushima. The populations of 12 communities were forced to evacuate after the accident; as of March 2016, the evacuation order has been lifted in only a limited area, and permanent habitation is still prohibited in most of the areas. In order for the government to lift the evacuation order and for individuals to return to their original residential areas, it is important to assess current and future realistic individual external doses. Here, we used personal dosimeters along with the Global Positioning System and Geographic Information System to understand realistic individual external doses and to relate individual external doses, ambient doses, and activity-patterns of individuals in the affected areas in Fukushima. The results showed that the additional individual external doses were well correlated to the additional ambient doses based on the airborne monitoring survey. The results of linear regression analysis suggested that the additional individual external doses were on average about one-fifth that of the additional ambient doses. The reduction factors, which are defined as the ratios of the additional individual external doses to the additional ambient doses, were calculated to be on average 0.14 and 0.32 for time spent at home and outdoors, respectively. Analysis of the contribution of various activity patterns to the total individual external dose demonstrated good agreement with the average fraction of time spent daily in each activity, but the contribution due to being outdoors varied widely. These results are a valuable contribution to understanding realistic individual external doses and the corresponding airborne monitoring-based ambient doses and time-activity patterns of individuals. Moreover, the results provide important information for predicting future cumulative doses after the return of residents to evacuation order areas in Fukushima. PMID:27494021

  7. Hemodialysis patients receiving a greater Kt dose than recommended have reduced mortality and hospitalization risk.

    PubMed

    Maduell, Francisco; Ramos, Rosa; Varas, Javier; Martin-Malo, Alejandro; Molina, Manuel; Pérez-Garcia, Rafael; Marcelli, Daniele; Moreso, Francesc; Aljama, Pedro; Merello, Jose Ignacio

    2016-12-01

    Achieving an adequate dialysis dose is one of the key goals for dialysis treatments. Here we assessed whether patients receiving the current cleared plasma volume (Kt), individualized for body surface area per recommendations, had improved survival and reduced hospitalizations at 2 years of follow-up. Additionally, we assessed whether patients receiving a greater dose gained more benefit. This prospective, observational, multicenter study included 6129 patients in 65 Fresenius Medical Care Spanish facilities. Patients were classified monthly into 1 of 10 risk groups based on the difference between achieved and target Kt. Patient groups with a more negative relationship were significantly older with a higher percentage of diabetes mellitus and catheter access. Treatment dialysis time, effective blood flow, and percentage of on-line hemodiafiltration were significantly higher in groups with a higher dose. The mortality risk profile showed a progressive increase when achieved minus target Kt became more negative but was significantly lower in the group with 1 to 3 L clearance above target Kt and in groups with greater increases above target Kt. Additionally, hospitalization risk appeared significantly reduced in groups receiving 9 L or more above the minimum target. Thus, prescribing an additional 3 L or more above the minimum Kt dose could potentially reduce mortality risk, and 9 L or more reduce hospitalization risk. As such, future prospective studies are required to confirm these dose effect findings. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  8. ADDITIVITY ASSESSMENT OF TRIHALOMETHANE MIXTURES BY PROPORTIONAL RESPONSE ADDITION

    EPA Science Inventory

    If additivity is known or assumed, the toxicity of a chemical mixture may be predicted from the dose response curves of the individual chemicals comprising the mixture. As single chemical data are abundant and mixture data sparse, mixture risk methods that utilize single chemical...

  9. Essentiality, toxicity, and uncertainty in the risk assessment of manganese.

    PubMed

    Boyes, William K

    2010-01-01

    Risk assessments of manganese by inhalation or oral routes of exposure typically acknowledge the duality of manganese as an essential element at low doses and a toxic metal at high doses. Previously, however, risk assessors were unable to describe manganese pharmacokinetics quantitatively across dose levels and routes of exposure, to account for mass balance, and to incorporate this information into a quantitative risk assessment. In addition, the prior risk assessment of inhaled manganese conducted by the U.S. Environmental Protection Agency (EPA) identified a number of specific factors that contributed to uncertainty in the risk assessment. In response to a petition regarding the use of a fuel additive containing manganese, methylcyclopentadienyl manganese tricarbonyl (MMT), the U.S. EPA developed a test rule under the U.S. Clean Air Act that required, among other things, the generation of pharmacokinetic information. This information was intended not only to aid in the design of health outcome studies, but also to help address uncertainties in the risk assessment of manganese. To date, the work conducted in response to the test rule has yielded substantial pharmacokinetic data. This information will enable the generation of physiologically based pharmacokinetic (PBPK) models capable of making quantitative predictions of tissue manganese concentrations following inhalation and oral exposure, across dose levels, and accounting for factors such as duration of exposure, different species of manganese, and changes of age, gender, and reproductive status. The work accomplished in response to the test rule, in combination with other scientific evidence, will enable future manganese risk assessments to consider tissue dosimetry more comprehensively than was previously possible.

  10. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol. 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines.more » In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios.« less

  11. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists.

    PubMed

    Farah, J; Struelens, L; Auvinen, A; Jacob, S; Koukorava, C; Schnelzer, M; Vanhavere, F; Clairand, I

    2015-04-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Radiotherapy for glioma during pregnancy: fetal dose estimates, risk assessment and clinical management.

    PubMed

    Haba, Y; Twyman, N; Thomas, S J; Overton, C; Dendy, P; Burnet, N G

    2004-05-01

    Cancer in pregnancy is relatively uncommon, but constitutes a major problem. We report the measurement of scatter dose to the fetus and the estimated fetal risk from that exposure in an illustrative case of a patient, 20 weeks pregnant, with a grade 3 anaplastic astrocytoma. A clinical decision was made to withhold radiotherapy, if possible, until after delivery. Sequential magnetic resonance imaging (MRI) showed no progression during the pregnancy. In the event, she was managed conservatively until the successful completion of her pregnancy. In case radiotherapy was required, an estimation of the fetal risk was made. Phantom measurements were undertaken to assess the likely fetal dose. Film badges were used to estimate the scattered radiation energy. Measurements were made on a Varian 600C at 6 MV and Asea Brown Boveri (ABB) accelerator at 8 and 16 MV. Doses were measured at 30, 45 and 60 cm from the isocentre; the fetus was assumed to lie at about 60 cm and not closer than 45 cm from the isocentre. Estimated doses to the position of the fetus were lowest with the 6 MV Varian accelerator. Using this machine without additional abdominal shielding, the estimated dose on the surface at 45 cm from the tumour volume was 2.2 cGy for a tumour dose of 54 Gy; using the ABB accelerator, the dose varied between 49-59 cGy. The energy of scattered radiation was in the range 208-688 keV, so that additional shielding would be practical to further reduce the fetal dose. The risk of cancer up to the age of 15 years attributable to radiation is 1 in 1700 per cGy, of which half will be fatal (i.e. 1 in 3300 per cGy). A dose of 2.2 cGy adds a risk of fatal cancer by the age 15 years of only 1 in 1500. Because the addition of shielding might halve the fetal dose, this risk should be reduced to 1 in 3000. For comparison, the overall UK risk of cancer up to the age 15 years is 1 in 650. In conclusion, careful choice of linear accelerator for the treatment of a pregnant woman and the use of additional shielding is valuable, as this can dramatically affect fetal dose.

  13. Biochemical and haematological assessment of toxic effects of the leaf ethanol extract of Petroselinum crispum (Mill) Nyman ex A.W. Hill (Parsley) in rats

    PubMed Central

    2013-01-01

    Background Petroselinum crispum, a bright green biennial shrub is widely used traditionally as a food additive and herbal remedies for many ailments. This study therefore aimed to assess the toxic effects of its leaf extract using some biochemical, haematological parameters. Methods The toxic effects were assessed by quantifying liver enzymes such as serum aspartate amino transferase (AST), alanine amino transferase (ALT), alkaline phosphatase (ALP), total serum protein and liver weight. Effects on haematological parameters were assessed by analysis of parked cell volume (PCV), red blood cell count (RBC), white blood cells (WBC) and haemoglobin (Hb) concentrations. Histopathological studies were done on the liver and kidneys. Results The extract caused significant increase in serum activity of alanine amino transferase and blood urea nitrogen (BUN) levels at the dose of 1000 mg/kg. Other biochemical and haematological parameters were not affected at lower doses. Conversely, the liver weight was not affected after eight weeks of treatment at the dose levels studied. The organs obtained for pathological study, were structurally unchanged under histopathological evaluation at lower doses but inflammatory and necrotic features were observed at doses ≥ 1000 mg/kg. Conclusion The results indicate that the leaf ethanol extract of Petroselinum crispum was hepatotoxic and nephrotoxic at continued oral doses equal to or more than 1000 mg/kg, but no obvious toxicity when used at lower doses. Therefore, there should be caution in its administration to avoid overdosing and known interaction with some medications. In addition, the plant should be kept away from pets and domestic animals and should not be cultivated on soil irrigated with waste water due to their ability to bio-accumulate toxic metals. PMID:23557241

  14. Biochemical and haematological assessment of toxic effects of the leaf ethanol extract of Petroselinum crispum (Mill) Nyman ex A.W. Hill (Parsley) in rats.

    PubMed

    Awe, Emmanuel Olorunju; Banjoko, S Olatunbosun

    2013-04-04

    Petroselinum crispum, a bright green biennial shrub is widely used traditionally as a food additive and herbal remedies for many ailments. This study therefore aimed to assess the toxic effects of its leaf extract using some biochemical, haematological parameters. The toxic effects were assessed by quantifying liver enzymes such as serum aspartate amino transferase (AST), alanine amino transferase (ALT), alkaline phosphatase (ALP), total serum protein and liver weight. Effects on haematological parameters were assessed by analysis of parked cell volume (PCV), red blood cell count (RBC), white blood cells (WBC) and haemoglobin (Hb) concentrations. Histopathological studies were done on the liver and kidneys. The extract caused significant increase in serum activity of alanine amino transferase and blood urea nitrogen (BUN) levels at the dose of 1000 mg/kg. Other biochemical and haematological parameters were not affected at lower doses. Conversely, the liver weight was not affected after eight weeks of treatment at the dose levels studied. The organs obtained for pathological study, were structurally unchanged under histopathological evaluation at lower doses but inflammatory and necrotic features were observed at doses ≥ 1000 mg/kg. The results indicate that the leaf ethanol extract of Petroselinum crispum was hepatotoxic and nephrotoxic at continued oral doses equal to or more than 1000 mg/kg, but no obvious toxicity when used at lower doses. Therefore, there should be caution in its administration to avoid overdosing and known interaction with some medications. In addition, the plant should be kept away from pets and domestic animals and should not be cultivated on soil irrigated with waste water due to their ability to bio-accumulate toxic metals.

  15. Evidence for Dose-Additive Effects of Pyrethroids on Motor Activity in Rats

    PubMed Central

    Wolansky, Marcelo J.; Gennings, Chris; DeVito, Michael J.; Crofton, Kevin M.

    2009-01-01

    Background Pyrethroids are neurotoxic insecticides used in a variety of indoor and outdoor applications. Previous research characterized the acute dose–effect functions for 11 pyrethroids administered orally in corn oil (1 mL/kg) based on assessment of motor activity. Objectives We used a mixture of these 11 pyrethroids and the same testing paradigm used in single-compound assays to test the hypothesis that cumulative neurotoxic effects of pyrethroid mixtures can be predicted using the default dose–addition theory. Methods Mixing ratios of the 11 pyrethroids in the tested mixture were based on the ED30 (effective dose that produces a 30% decrease in response) of the individual chemical (i.e., the mixture comprised equipotent amounts of each pyrethroid). The highest concentration of each individual chemical in the mixture was less than the threshold for inducing behavioral effects. Adult male rats received acute oral exposure to corn oil (control) or dilutions of the stock mixture solution. The mixture of 11 pyrethroids was administered either simultaneously (2 hr before testing) or after a sequence based on times of peak effect for the individual chemicals (4, 2, and 1 hr before testing). A threshold additivity model was fit to the single-chemical data to predict the theoretical dose–effect relationship for the mixture under the assumption of dose additivity. Results When subthreshold doses of individual chemicals were combined in the mixtures, we found significant dose-related decreases in motor activity. Further, we found no departure from the predicted dose-additive curve regardless of the mixture dosing protocol used. Conclusion In this article we present the first in vivo evidence on pyrethroid cumulative effects supporting the default assumption of dose addition. PMID:20019907

  16. Review and comparison between the Wells-Riley and dose-response approaches to risk assessment of infectious respiratory diseases.

    PubMed

    Sze To, G N; Chao, C Y H

    2010-02-01

    Infection risk assessment is very useful in understanding the transmission dynamics of infectious diseases and in predicting the risk of these diseases to the public. Quantitative infection risk assessment can provide quantitative analysis of disease transmission and the effectiveness of infection control measures. The Wells-Riley model has been extensively used for quantitative infection risk assessment of respiratory infectious diseases in indoor premises. Some newer studies have also proposed the use of dose-response models for such purpose. This study reviews and compares these two approaches to infection risk assessment of respiratory infectious diseases. The Wells-Riley model allows quick assessment and does not require interspecies extrapolation of infectivity. Dose-response models can consider other disease transmission routes in addition to airborne route and can calculate the infectious source strength of an outbreak in terms of the quantity of the pathogen rather than a hypothetical unit. Spatial distribution of airborne pathogens is one of the most important factors in infection risk assessment of respiratory disease. Respiratory deposition of aerosol induces heterogeneous infectivity of intake pathogens and randomness on the intake dose, which are not being well accounted for in current risk models. Some suggestions for further development of the risk assessment models are proposed. This review article summarizes the strengths and limitations of the Wells-Riley and the dose-response models for risk assessment of respiratory diseases. Even with many efforts by various investigators to develop and modify the risk assessment models, some limitations still persist. This review serves as a reference for further development of infection risk assessment models of respiratory diseases. The Wells-Riley model and dose-response model offer specific advantages. Risk assessors can select the approach that is suitable to their particular conditions to perform risk assessment.

  17. Application of the Extended Health Control Belief Model to Predict Hepatitis A and B Vaccinations.

    PubMed

    Reynolds, Grace L; Nguyen, Hannah H; Singh-Carlson, Savitri; Fisher, Dennis G; Odell, Anne; Xandre, Pamela

    2016-09-01

    Adult vaccination compliance rates vary according to sample and type of vaccine administered (influenza, pneumococcal). This study looked at vaccination of a community sample of low-income, minority adults. Nurses offered free vaccination for hepatitis A and B in the form of the combined Twinrix vaccine to adults on a walk-in basis. In addition to dosing information, participants completed the Risk Behavior Assessment, the Coping Strategies Indicator and the Cardiovascular Risk Assessment. Skaff's extended Health Belief Model was used as the theoretical framework. Count regression was used to model receipt of one, two, or three doses. The majority of participants were male with a mean age of 40 years. The distribution of doses was: 173 individuals (27.6%) received one dose only, 261 (41.7%) received two doses, and 191 (30.5%) received three doses of vaccine. The multivariate count regression model including being male, having previously been told by a health care provider that one has syphilis, having severe negative emotions, and perceived social support were associated with participants' receiving fewer doses of hepatitis vaccine. A greater problem-solving score was associated with a higher number of vaccine doses received. Despite free vaccinations offered in an easily accessible community setting, the majority of participants failed to complete the hepatitis vaccine series. More effort is needed to get adult men to participate in hepatitis vaccination clinics. Additional research is necessary to understand barriers other than cost to adults receiving vaccination. © 2016 Wiley Periodicals, Inc.

  18. Efficacy and safety of additional 200-mg dose of celecoxib in adult patients with postoperative pain following extraction of impacted third mandibular molar: a multicenter, randomized, double-blind, placebo-controlled, phase II study in Japan.

    PubMed

    Saito, Ken'ichi; Kaneko, Akihiro; Machii, Katsuyuki; Ohta, Hiroyoshi; Ohkura, Masayuki; Suzuki, Makoto

    2012-02-01

    Although third mandibular molar extraction is a widely used and validated model of acute pain for evaluating analgesic efficacy, a large proportion of patients experience moderate or severe pain following this procedure and require analgesia. Current treatment options have been associated with safety concerns and alternative therapies are sought. Our aim was to assess the efficacy and safety of an additional 200-mg dose of celecoxib, administered 5 to 12 hours after an initial 400-mg dose of the drug for the treatment of moderate or severe acute pain following extraction of an impacted third mandibular molar. This was a multicenter, randomized, double-blind, placebo-controlled, Phase II study. Patients experiencing moderate or severe pain within 1 to 2 hours following extraction of an impacted third mandibular molar received an initial 400-mg dose of celecoxib. Patients requiring additional analgesia were subsequently randomized to receive either an additional 200-mg dose of celecoxib or placebo 5 to 12 hours after the initial dose. The study was designed and conducted by Pfizer Inc. for approval of celecoxib in Japan for the indication of acute pain. The primary end point was the patient's impression of efficacy (4-category global evaluation scale). Secondary efficacy end points included pain intensity on a 4-category pain intensity scale, pain intensity on a 100-mm visual analog scale (VAS), and the pain intensity difference (100-mm VAS). In an exploratory analysis, use of rescue medication was evaluated. Primary and secondary end points were analyzed using the full analysis set. Assessment of the safety profile included a physical examination, measurement of pulse rate and blood pressure, standard 12-lead ECG, and laboratory tests. A total of 69 patients (celecoxib, 42/64 [65.6%]; placebo, 27/58 [46.6%]) received the additional dose of study medication; all completed the study without the need for rescue medication. A significantly higher proportion of patients in the celecoxib 200 mg group (41/64 [64.1%]) compared with the placebo group (15/58 [25.9%]) rated the study medication as "good" or "excellent" ≥ 2 hours after the additional dose (P < 0.0001). Pain intensity (VAS) 2 hours after the additional dose was significantly higher in the placebo group than in the celecoxib 200 mg group (P = 0.0003). The reduction in pain intensity from baseline to 2 hours after the additional dose of study medication was also significantly greater in the celecoxib 200 mg group than in the placebo group (P < 0.0001). The incidence of treatment-related, all-cause adverse events was slightly lower in patients receiving celecoxib 200 mg (20.3%) compared with placebo (31.0%). Overall, an additional 200-mg dose of celecoxib was well tolerated and efficacious in reducing the pain associated with extraction of an impacted third mandibular molar in the study population. ClinicalTrials.gov identifier: NCT01062113. Copyright © 2012 Elsevier HS Journals, Inc. All rights reserved.

  19. Case control study to assess the possibility of decrease the risk of osteoradionecrosis in relation to the dose of radiation absorbed by the jaw

    PubMed Central

    Carini, Fabrizio; Bucalo, Concetta; Saggese, Vito; Monai, Dario; Porcaro, Gianluca

    2012-01-01

    Summary Aims the assessment of the limit dose for the organs at risk in external radiotherapy is a fundamental step to guarantee an optimal risk-benefit ratio. The aim of this study was to assess, through contouring the single dental cavities, the absorbed radiation dose on irradiated alveolar bones during the treatment of cervico-facial tumours, so as to test the correlation between the absorbed dose of radiation at alveolar level and the level of individual surgical risk for osteonecrosis. Materials and methods we selected 45 out of 89 patients on the basis of different exclusion criteria. Nine of these patients showed evidence of osteoradionecrosis. The patients were treated either with 3D conformational radiation therapy (3D-CRT) or with intensity-modulated radiation therapy (IMRT), there after alveolar bones were contoured using computed axial tomography (CAT scans) carried out following oncological and dental treatment. The dose-volume histograms (DVH) were obtained on the basis of such data, which included those relating to the dental cavities in addition to those inherent to the tumours and the organs at risk. Results all patients, irrespective of type of treatment, received an average of 60 to 70 grays in 30/35 sittings. The patients treated with IMRT showed higher variation in absorbed radiation dose than those treated with 3D-CRT. The alveolar encirclement allowed the assessment of the absorbed radiation dose, and consequently it also allowed to assess the individual surgical risk for osteonecrosis in patients with head and neck tumours who underwent radiography treatment. Conclusions the study of DVH allows the assessment of limit dose and the detection of the areas at greater risk for osteoradionecrosis before dental surgery. PMID:23285316

  20. Defining an additivity framework for mixture research in inducible whole-cell biosensors

    NASA Astrophysics Data System (ADS)

    Martin-Betancor, K.; Ritz, C.; Fernández-Piñas, F.; Leganés, F.; Rodea-Palomares, I.

    2015-11-01

    A novel additivity framework for mixture effect modelling in the context of whole cell inducible biosensors has been mathematically developed and implemented in R. The proposed method is a multivariate extension of the effective dose (EDp) concept. Specifically, the extension accounts for differential maximal effects among analytes and response inhibition beyond the maximum permissive concentrations. This allows a multivariate extension of Loewe additivity, enabling direct application in a biphasic dose-response framework. The proposed additivity definition was validated, and its applicability illustrated by studying the response of the cyanobacterial biosensor Synechococcus elongatus PCC 7942 pBG2120 to binary mixtures of Zn, Cu, Cd, Ag, Co and Hg. The novel method allowed by the first time to model complete dose-response profiles of an inducible whole cell biosensor to mixtures. In addition, the approach also allowed identification and quantification of departures from additivity (interactions) among analytes. The biosensor was found to respond in a near additive way to heavy metal mixtures except when Hg, Co and Ag were present, in which case strong interactions occurred. The method is a useful contribution for the whole cell biosensors discipline and related areas allowing to perform appropriate assessment of mixture effects in non-monotonic dose-response frameworks

  1. Investigation of the practical aspects of an additional 0.1 mm copper x-ray spectral filter for cine acquisition mode imaging in a clinical care setting.

    PubMed

    Fetterly, Kenneth A

    2010-11-01

    Minimizing the x-ray radiation dose is an important aspect of patient safety during interventional fluoroscopy procedures. This work investigates the practical aspects of an additional 0.1 mm Cu x-ray beam spectral filter applied to cine acquisition mode imaging on patient dose and image quality. Measurements were acquired using clinical interventional imaging systems. Acquisition images of Solid Water phantoms (15-40 cm) were acquired using x-ray beams with the x-ray tube inherent filtration and using an additional 0.1 mm Cu x-ray beam spectral filter. The skin entrance air kerma (dose) rate was measured and the signal difference to noise ratio (SDNR) of an iodine target embedded into the phantom was calculated to assess image quality. X-ray beam parameters were recorded and analyzed and a primary x-ray beam simulation was performed to assess additional x-ray tube burden attributable to the Cu filter. For all phantom thicknesses, the 0.1 mm Cu filter resulted in a 40% reduction in the entrance air kerma rate to the phantoms and a 9% reduction in the SDNR of the iodine phantom. The expected additional tube load required by the 0.1 mm Cu filter ranged from 11% for a 120 kVp x-ray beam to 43% for a 60 kVp beam. For these clinical systems, use of the 0.1 mm Cu filter resulted in a favorable compromise between reduced skin dose rate and image quality and increased x-ray tube burden.

  2. No-threshold dose-response curves for nongenotoxic chemicals: Findings and applications for risk assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, Daniel M.

    2006-01-15

    We tested the hypothesis that no threshold exists when estradiol acts through the same mechanism as an active endogenous estrogen. A Michaelis-Menten (MM) equation accounting for response saturation, background effects, and endogenous estrogen level fit a turtle sex-reversal data set with no threshold and estimated the endogenous dose. Additionally, 31 diverse literature dose-response data sets were analyzed by adding a term for nonhormonal background; good fits were obtained but endogenous dose estimations were not significant due to low resolving power. No thresholds were observed. Data sets were plotted using a normalized MM equation; all 178 data points were accommodated onmore » a single graph. Response rates from {approx}1% to >95% were well fit. The findings contradict the threshold assumption and low-dose safety. Calculating risk and assuming additivity of effects from multiple chemicals acting through the same mechanism rather than assuming a safe dose for nonthresholded curves is appropriate.« less

  3. Comparison of current recommended regimens of atropinization in organophosphate poisoning.

    PubMed

    Connors, Nicholas J; Harnett, Zachary H; Hoffman, Robert S

    2014-06-01

    Atropine is the mainstay of therapy in organophosphate (OP) toxicity, though research and consensus on dosing is lacking. In 2004, as reported by Eddleston et al. (J Toxicol Clin Toxicol 42(6):865-75, 2004), they noted variation in recommended regimens. We assessed revisions of original references, additional citations, and electronic sources to determine the current variability in atropine dosing recommendations. Updated editions of references from Eddleston et al.'s work, texts of Internal and Emergency Medicine, and electronic resources were reviewed for atropine dosing recommendations. For comparison, recommendations were assessed using the same mean dose (23.4 mg) and the highest dose (75 mg) of atropine as used in the original paper. Recommendations were also compared with the dosing regimen from the World Health Organization (WHO). Thirteen of the original recommendations were updated and 15 additional references were added giving a convenience sample of 28. Sufficient information to calculate time to targeted dose was provided by 24 of these samples. Compared to 2004, current recommendations have greatly increased the speed of atropinization with 13/24 able to reach the mean and high atropine dose within 30 min compared to 1/36 in 2004. In 2004, there were 13 regimens where the maximum time to reach 75 mg was over 18 h, whereas now, there are 2. While only one recommendation called for doubling the dose for faster escalation in 2004, 15 of the 24 current works include dose doubling. In 2004, Eddleston et al. called for an evidence-based guideline for the treatment of OP poisoning that could be disseminated worldwide. Many current recommendations can adequately treat patients within 1 h. While the WHO recommendations remain slow to treat patients with OP poisoning, other authorities are close to a consensus on rapid atropinization.

  4. NP001 regulation of macrophage activation markers in ALS: A phase I clinical and biomarker study

    PubMed Central

    MILLER, ROBERT G.; ZHANG, RONGZHEN; BLOCK, GILBERT; KATZ, JONATHAN; BAROHN, RICHARD; KASARSKIS, EDWARD; FORSHEW, DALLAS; GOPALAKRISHNAN, VIDHYA; MCGRATH, MICHAEL S.

    2017-01-01

    This is a phase I, placebo-controlled, single ascending dose safety and tolerability study of NP001 in patients with ALS. NP001 is a novel regulator of inflammatory macrophages and monocytes. As ALS progression is thought to be related to neuroinflammation, an additional objective of the study was to assess the effects of NP001 administration on monocyte activation markers. Thirty-two ALS patients were enrolled and received either placebo (eight) or one of four (six at each dose) ascending single i.v. doses (0.2, 0.8, 1.6 and 3.2 mg/kg NP001). Patients were monitored for safety, and blood monocyte immune activation markers CD16 and HLA-DR were assessed pre- and 24 h post-dosing. Changes from baseline were calculated. Results showed that NP001 was generally safe and well tolerated. Importantly, a single dose of NP001 caused a dose-dependent reduction in expression of monocyte CD16, a marker of monocyte activation/inflammation. Additionally, monocyte HLA-DR expression was also decreased in those patients with elevated values at baseline. In conclusion, these data indicate that NP001 has an acute effect on inflammatory monocytes in ALS patient blood. The potential for modulation of inflammation in the context of ALS disease progression will require further study with long-term follow-up. PMID:25192333

  5. The incidence of acute oxaliplatin-induced neuropathy and its impact on treatment in the first cycle: a systematic review.

    PubMed

    Gebremedhn, Endale Gebreegziabher; Shortland, Peter John; Mahns, David Anthony

    2018-04-12

    Although acute oxaliplatin-induced neuropathy (OXIPN) is frequently regarded to be transient, recent studies have reported prolongation of infusion times, dose reduction and treatment cessation following the first dose of oxaliplatin in quarter of patients. Acute OXIPN is also a well-established risk factor for chronic neuropathy. However, there is underreporting of these parameters during the acute phase (≤ 14 days). This paper systematically reviews the incidence of acute OXIPN and its impact on treatment in the first cycle. A systematic literature search was performed using PubMed and Medline. Published original articles were included if they described details about prevalence of oxaliplatin-induced acute neuropathy. Fourteen studies, comprised of 6211 patients were evaluated. The majority of patients were treated with oxaliplatin in combination with leucovorin and fluorouracil (FOLFOX). Most studies used the National Cancer Institute Common Toxicity Criteria to assess acute neuropathy. Acute neuropathy (Grades 1-4) was the most common event with prevalence ranging from 4-98%, followed by haematological (1.4-81%) and gastrointestinal (1.2-67%) toxicities, respectively. Drug regimens, starting dose of oxaliplatin and neuropathy assessment tools varied across studies. In addition, moderate to severe toxicities were common in patients that received a large dose of oxaliplatin (> 85 mg/m 2 ) and/ or combined drugs. The majority of studies did not report the factors affecting acute neuropathy namely the range (minimal) doses required to evoke acute neuropathy, patient and clinical risk factors. In addition, there was no systematic reporting of the number of patients subjected to prolonged infusion, dose reduction, treatment delay and treatment cessation during the acute phase. Despite the heterogeneity of studies regarding oxaliplatin starting dose, drug regimen, neuropathy assessment tools and study design, a large number of patients developed acute neuropathy. To develop a better preventive and therapeutic guideline for acute/chronic neuropathy, a prospective study should be conducted in a large cohort of patients in relation to drug regimen, starting/ranges (minimal) of doses producing acute neuropathy, treatment compliance, patient and clinical risk factors using a standardised neuropathy assessment tool.

  6. Characterization of the disposition of fostamatinib in Japanese subjects including pharmacokinetic assessment in dry blood spots: results from two phase I clinical studies.

    PubMed

    Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael

    2016-01-01

    The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.

  7. [Diagnosis of cerebral metastasis with standard dose gadobutrol vs. a high dose protocol. Intraindividual evaluation of a phase II high dose study].

    PubMed

    Vogl, T J; Friebe, C E; Balzer, T; Mack, M G; Steiner, S; Schedel, H; Pegios, W; Lanksch, W; Banzer, D; Felix, R

    1995-08-01

    To assess the effectiveness and safety of normal and high doses of Gadobutrol versus a standard dose of Gadolinium DTPA in the MR evaluation of patients with brain metastases. In a clinical phase-II study 20 patients who had been diagnosed as having brain metastases with CT or MRT were studied prospectively with Gadobutrol, a new nonionic, low osmolality contrast agent. Each patient received an initial injection of 0.1 mmol/kg body weight and an additional dose of 0.2 mmol/kg Gadobutrol 10 min later. Spin-echo images were obtained before and after the two applications of Gadobutrol. Dynamic scanning (Turbo-FLASH) was performed for 3 min after each injection of the contrast agent. Both quantitative and qualitative data were intraindividually evaluated. The primary tumor was a bronchial carcinoma in 11 cases; in 9 other cases there were different primary tumors. Forty-eight hours after the use of Gadobutrol there were no adverse signs in the clinical examination, vital signs or blood and urine chemistry. Statistical analysis (Friedman test and Wilcoxon test) of the C/N ratios between tumor and white matter, percentage enhancement, and visual assessment rating revealed statistically significant superiority of high-dose Gadobutrol injection in comparison to the standard dose. The percentage enhancement increased on average from 104% after 0.1 mmol/kg to 162% after 0.3 mmol/kg Gadobutrol. Qualitative delineation and contrast of the lesions increased significantly. The use of high-dose Gadobutrol improved the detection of 36 additional lesions in 6 patients. The first in vivo results prove the excellent contrast capacity of the nonionic contrast agent Gadobutrol for the diagnosis of intracerebral metastases.

  8. Cumulative effects of anti-androgenic chemical mixtures and ...

    EPA Pesticide Factsheets

    Kembra L. Howdeshell and L. Earl Gray, Jr.Toxicological studies of defined chemical mixtures assist human health risk assessment by characterizing the joint action of chemicals. This presentation will review the effects of anti-androgenic chemical mixtures on reproductive tract development in rats with a special focus on the reproductive toxicant phthalates. Observed mixture data are compared to mathematical mixture model predictions to determine how the individual chemicals in a mixture interact (e.g., response addition – probabilities of response for each individual chemical are added; dose-addition – the doses of each individual chemical at a given mixture dose are combined together based on the relative potency of the individual chemicals). Phthalate mixtures are observed to act in a dose-additive manner based on the relative potency of the individual phthalates to suppress fetal testosterone production. Similar dose-additive effects have been reported for mixtures of phthalates with anti-androgenic pesticides of differing mechanisms. Data from these phthalate experiments in rats can be used in conjunction with human biomonitoring data to determine individual hazard ratios. Furthermore, data from the toxicological studies can inform the analysis of human biomonitoring data on the association of detected chemicals and their metabolites with measured health outcomes. Data from phthalate experiments in rats can be used in conjunction with human biomonit

  9. Introduction of risk size in the determination of uncertainty factor UFL in risk assessment

    NASA Astrophysics Data System (ADS)

    Xue, Jinling; Lu, Yun; Velasquez, Natalia; Yu, Ruozhen; Hu, Hongying; Liu, Zhengtao; Meng, Wei

    2012-09-01

    The methodology for using uncertainty factors in health risk assessment has been developed for several decades. A default value is usually applied for the uncertainty factor UFL, which is used to extrapolate from LOAEL (lowest observed adverse effect level) to NAEL (no adverse effect level). Here, we have developed a new method that establishes a linear relationship between UFL and the additional risk level at LOAEL based on the dose-response information, which represents a very important factor that should be carefully considered. This linear formula makes it possible to select UFL properly in the additional risk range from 5.3% to 16.2%. Also the results remind us that the default value 10 may not be conservative enough when the additional risk level at LOAEL exceeds 16.2%. Furthermore, this novel method not only provides a flexible UFL instead of the traditional default value, but also can ensure a conservative estimation of the UFL with fewer errors, and avoid the benchmark response selection involved in the benchmark dose method. These advantages can improve the estimation of the extrapolation starting point in the risk assessment.

  10. Multifaceted empathy of healthy volunteers after single doses of MDMA: A pooled sample of placebo-controlled studies

    PubMed Central

    Kuypers, Kim PC; Dolder, Patrick C; Ramaekers, Johannes G; Liechti, Matthias E

    2017-01-01

    Previous placebo-controlled experimental studies have shown that a single dose of MDMA can increase emotional empathy in the multifaceted empathy test (MET) without affecting cognitive empathy. Although sufficiently powered to detect main effects of MDMA, these studies were generally underpowered to also validly assess contributions of additional parameters, such as sex, drug use history, trait empathy and MDMA or oxytocin plasma concentrations. The present study examined the robustness of the MDMA effect on empathy and investigated the moderating role of these additional parameters. Participants (n = 118) from six placebo-controlled within-subject studies and two laboratories were included in the present pooled analysis. Empathy (MET), MDMA and oxytocin plasma concentrations were assessed after oral administration of MDMA (single dose, 75 or 125 mg). Trait empathy was assessed using the interpersonal reactivity index. We confirmed that MDMA increased emotional empathy at both doses without affecting cognitive empathy. This MDMA-related increase in empathy was most pronounced during presentation of positive emotions as compared with negative emotions. MDMA-induced empathy enhancement was positively related to MDMA blood concentrations measured before the test, but independent of sex, drug use history and trait empathy. Oxytocin concentrations increased after MDMA administration but were not associated with behavioral effects. The MDMA effects on emotional empathy were stable across laboratories and doses. Sex did not play a moderating role in this effect, and oxytocin levels, trait empathy and drug use history were also unrelated. Acute drug exposure was of significant relevance in the MDMA-induced emotional empathy elevation. PMID:28372480

  11. Multifaceted empathy of healthy volunteers after single doses of MDMA: A pooled sample of placebo-controlled studies.

    PubMed

    Kuypers, Kim Pc; Dolder, Patrick C; Ramaekers, Johannes G; Liechti, Matthias E

    2017-05-01

    Previous placebo-controlled experimental studies have shown that a single dose of MDMA can increase emotional empathy in the multifaceted empathy test (MET) without affecting cognitive empathy. Although sufficiently powered to detect main effects of MDMA, these studies were generally underpowered to also validly assess contributions of additional parameters, such as sex, drug use history, trait empathy and MDMA or oxytocin plasma concentrations. The present study examined the robustness of the MDMA effect on empathy and investigated the moderating role of these additional parameters. Participants ( n = 118) from six placebo-controlled within-subject studies and two laboratories were included in the present pooled analysis. Empathy (MET), MDMA and oxytocin plasma concentrations were assessed after oral administration of MDMA (single dose, 75 or 125 mg). Trait empathy was assessed using the interpersonal reactivity index. We confirmed that MDMA increased emotional empathy at both doses without affecting cognitive empathy. This MDMA-related increase in empathy was most pronounced during presentation of positive emotions as compared with negative emotions. MDMA-induced empathy enhancement was positively related to MDMA blood concentrations measured before the test, but independent of sex, drug use history and trait empathy. Oxytocin concentrations increased after MDMA administration but were not associated with behavioral effects. The MDMA effects on emotional empathy were stable across laboratories and doses. Sex did not play a moderating role in this effect, and oxytocin levels, trait empathy and drug use history were also unrelated. Acute drug exposure was of significant relevance in the MDMA-induced emotional empathy elevation.

  12. Mixture Toxicity of SN2-Reactive Soft Electrophiles: 2—Evaluation of Mixtures Containing Ethyl α-Halogenated Acetates

    PubMed Central

    Mooneyham, T.; Jeyaratnam, J.; Schultz, T. W.; Pöch, G.

    2011-01-01

    Four ethyl α-halogenated acetates were tested in (1) sham and (2) nonsham combinations and (3) with a nonreactive nonpolar narcotic. Ethyl iodoacetate (EIAC), ethyl bromoacetate (EBAC), ethyl chloroacetate (ECAC), and ethyl fluoroacetate (EFAC), each considered to be an SN2-H-polar soft electrophile, were selected for testing based on their differences in electro(nucleo)philic reactivity and time-dependent toxicity (TDT). Agent reactivity was assessed using the model nucleophile glutathione, with EIAC and EBAC showing rapid reactivity, ECAC being less reactive, and EFAC lacking reactivity at ≤250 mM. The model nonpolar narcotic, 3-methyl-2-butanone (3M2B), was not reactive. Toxicity of the agents alone and in mixture was assessed using the Microtox acute toxicity test at three exposure durations: 15, 30 and 45 min. Two of the agents alone (EIAC and EBAC) had TDT values >100%. In contrast, ECAC (74 to 99%) and EFAC (9 to 12%) had partial TDT, whereas 3M2B completely lacked TDT (<0%). In mixture testing, sham combinations of each agent showed a combined effect consistent with predicted effects for dose-addition at each time point, as judged by EC50 dose-addition quotient values. Mixture toxicity results for nonsham ethyl acetate combinations were variable, with some mixtures being inconsistent with the predicted effects for dose-addition and/or independence. The ethyl acetate–3M2B combinations were somewhat more toxic than predicted for dose-addition, a finding differing from that observed previously for α-halogenated acetonitriles with 3M2B. PMID:21452006

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, S; Green, G; Sehgal, V

    Purpose: The purpose of this study is to assess the dose response of radioembolization using yttrium-90 (Y-90) microspheres in patients treated for unresectable cholangiocarcinoma. This study utilized partition dosimetry model for the dose calculation. The results show survival benefit with dose escalation. Methods: Between February 2009 and March 2013, ten patients with pathology proven unresectable cholangiocarcinoma were radioembolized with Y-90 microspheres. Patients underwent initial pre-treatment angiographic assessment for blood flow and 99mTc- MAA for lung shunt evaluation. Activity of Y-90 administration was calculated using the Body Surface Area (BSA) and target volumes which were determined by contouring the pre-treatment MRI/CTmore » images using a radiation therapy treatment planning system. Medical Internal Radiation Dose (MIRD) method was used to assess the dosimetric results of Y90. Partition model based on the tumor to-liver activity uptake estimated from pretreatment 99mTc- MAA study was used to calculate the dose delivered to the target. The variables assessed included: administered dose, toxicity based on clinical changes, imaging based tumor response, and survival. Results: Ten patients were radioembolized with Y-90 microspheres to either one hepatic lobe or both left and right lobes. Patients were stratified by dose. Four patients who received dose greater than 140Gy (p < 0.05) all survived. The corresponding activity they received was greater than 35 mCi. Six out of ten patients died of disease with median survival of 18 weeks (range 12–81wks). Conclusion: Given the growing body of data for Y-90 microspheres in the context of cholangiocarcinoma, radioembolization may become an important treatment modality for an appropriately selected group of patients. Our study further substantiates past studies and shows additional evidence of a survival benefit with dose escalation.« less

  14. Biological characterization of a novel in vitro cell irradiator

    PubMed Central

    Fowler, Tyler L.; Fisher, Michael M.; Bailey, Alison M.; Bednarz, Bryan P.

    2017-01-01

    To evaluate the overall robustness of a novel cellular irradiator we performed a series of well-characterized, dose-responsive assays to assess the consequences of DNA damage. We used a previously described novel irradiation system and a traditional 137Cs source to irradiate a cell line. The generation of reactive oxygen species was assessed using chloromethyl-H2DCFDA dye, the induction of DNA DSBs was observed using the comet assay, and the initiation of DNA break repair was assessed through γH2AX image cytometry. A high correlation between physical absorbed dose and biologic dose was seen for the production of intracellular reactive oxygen species, physical DNA double strand breaks, and modulation of the cellular double stand break pathway. The results compared favorably to irradiation with a traditional 137Cs source. The rapid, straightforward tests described form a reasonable approach for biologic characterization of novel irradiators. These additional testing metrics go beyond standard physics testing such as Monte Carlo simulation and thermo-luminescent dosimeter evaluation to confirm that a novel irradiator can produce the desired dose effects in vitro. Further, assessment of these biological metrics confirms that the physical handling of the cells during the irradiation process results in biologic effects that scale appropriately with dose. PMID:29232400

  15. Potential uncertainty reduction in model-averaged benchmark dose estimates informed by an additional dose study.

    PubMed

    Shao, Kan; Small, Mitchell J

    2011-10-01

    A methodology is presented for assessing the information value of an additional dosage experiment in existing bioassay studies. The analysis demonstrates the potential reduction in the uncertainty of toxicity metrics derived from expanded studies, providing insights for future studies. Bayesian methods are used to fit alternative dose-response models using Markov chain Monte Carlo (MCMC) simulation for parameter estimation and Bayesian model averaging (BMA) is used to compare and combine the alternative models. BMA predictions for benchmark dose (BMD) are developed, with uncertainty in these predictions used to derive the lower bound BMDL. The MCMC and BMA results provide a basis for a subsequent Monte Carlo analysis that backcasts the dosage where an additional test group would have been most beneficial in reducing the uncertainty in the BMD prediction, along with the magnitude of the expected uncertainty reduction. Uncertainty reductions are measured in terms of reduced interval widths of predicted BMD values and increases in BMDL values that occur as a result of this reduced uncertainty. The methodology is illustrated using two existing data sets for TCDD carcinogenicity, fitted with two alternative dose-response models (logistic and quantal-linear). The example shows that an additional dose at a relatively high value would have been most effective for reducing the uncertainty in BMA BMD estimates, with predicted reductions in the widths of uncertainty intervals of approximately 30%, and expected increases in BMDL values of 5-10%. The results demonstrate that dose selection for studies that subsequently inform dose-response models can benefit from consideration of how these models will be fit, combined, and interpreted. © 2011 Society for Risk Analysis.

  16. Estimating the impact of grouping misclassification on risk prediction when using the relative potency factors method to assess mixtures risk

    EPA Science Inventory

    Environmental health risk assessments of chemical mixtures that rely on component approaches often begin by grouping the chemicals of concern according to toxicological similarity. Approaches that assume dose addition typically are used for groups of similarly-acting chemicals an...

  17. DNA Reactivity as a Mode of Action and Its Relevance to Cancer Risk Assessment

    EPA Science Inventory

    The ability of a chemical to induce mutations has long been a driver in the cancer risk assessment process. The default strategy has been that mutagenic chemicals demonstrate linear cancer dose responses, especially at low exposure levels. In the absence of additional confounding...

  18. Effect of increased CRM₁₉₇ carrier protein dose on meningococcal C bactericidal antibody response.

    PubMed

    Lee, Lucia H; Blake, Milan S

    2012-04-01

    New multivalent CRM(197)-based conjugate vaccines are available for childhood immunization. Clinical studies were reviewed to assess meningococcal group C (MenC) antibody responses following MenC-CRM(197) coadministration with CRM(197)-based pneumococcal or Haemophilus influenzae type b conjugate vaccines. Infants receiving a total CRM(197) carrier protein dose of ∼50 μg and concomitant diphtheria-tetanus-acellular pertussis (DTaP)-containing vaccine tended to have lower MenC geometric mean antibody titers and continued to have low titers after the toddler dose. Nevertheless, at least 95% of children in the reported studies achieved a MenC serum bactericidal antibody (SBA) titer of ≥ 1:8 after the last infant or toddler dose. SBA was measured using an assay with a baby rabbit or human complement source. Additional studies are needed to assess long-term antibody persistence and MenC CRM(197) conjugate vaccine immunogenicity using alternative dosing schedules.

  19. The use of ESR spectroscopy for the identification and dose assessment of irradiated pink shrimp (Parapenaeus longirostris) from Turkey

    NASA Astrophysics Data System (ADS)

    Aydaş, Canan; Tepe Çam, Semra; Engin, Birol; Aydın, Talat; Polat, Mustafa

    2013-03-01

    Turkish pink shrimp (Parapenaeus longirostris) samples were studied by electron spin resonance (ESR) spectroscopy for identification and dose assessment purposes. In this work, the calcified shells of shrimps were used as a sample material. Before irradiation, all shrimp shell samples exhibit one weak ESR singlet with a g-factor of 2.0047. After irradiation, all samples exhibit two asymmetric ESR signal components centered at g-values of 2.0013 and 1.9959. The dose-response curves of the samples exposed to gamma radiations were found to be described well by a single saturation exponential function. Variation of ESR signal intensity of irradiated samples at room and-20 °C temperatures with time in a long-term showed that free radicals responsible from the ESR spectrum of shrimp shells were not stable but still detectable after 87 days. Also, the kinetic behavior of signal at g=2.0013 was studied and the additive dose method was used to evaluate the dose in the product.

  20. Individualized texting for adherence building (iTAB): improving antiretroviral dose timing among HIV-infected persons with co-occurring bipolar disorder.

    PubMed

    Moore, David J; Poquette, Amelia; Casaletto, Kaitlin B; Gouaux, Ben; Montoya, Jessica L; Posada, Carolina; Rooney, Alexandra S; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L; Depp, Colin A; Grant, Igor; Atkinson, J Hampton

    2015-03-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff's d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff's d = -0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff's d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation.

  1. Individualized Texting for Adherence Building (iTAB): Improving Antiretroviral Dose Timing Among HIV-Infected Persons with Co-occurring Bipolar Disorder

    PubMed Central

    Poquette, Amelia; Casaletto, Kaitlin B.; Gouaux, Ben; Montoya, Jessica L.; Posada, Carolina; Rooney, Alexandra S.; Badiee, Jayraan; Deutsch, Reena; Letendre, Scott L.; Depp, Colin A.; Grant, Igor; Atkinson, J. Hampton

    2015-01-01

    HIV+ persons with co-occurring bipolar disorder (HIV+/BD+) have elevated rates of medication nonadherence. We conducted a 30-day randomized controlled trial of a two-way, text messaging system, iTAB (n = 25), compared to an active comparison (CTRL) (n = 25) to improve antiretroviral (ARV) and psychotropic (PSY) adherence and dose timing. Both groups received medication adherence psychoeducation and daily texts assessing mood. The iTAB group additionally received personalized medication reminder texts. Participants responded to over 90 % of the mood and adherence text messages. Mean adherence, as assessed via electronic monitoring caps, was high and comparable between groups for both ARV (iTAB 86.2 % vs. CTRL 84.8 %; p = 0.95, Cliff’s d = 0.01) and PSY (iTAB 78.9 % vs. CTRL 77.3 %; p = 0.43, Cliff’s d = −0.13) medications. However, iTAB participants took ARVs significantly closer to their intended dosing time than CTRL participants (iTAB: 27.8 vs. CTRL: 77.0 min from target time; p = 0.02, Cliff’s d = 0.37). There was no group difference on PSY dose timing. Text messaging interventions may represent a low-burden approach to improving timeliness of medication-taking behaviors among difficult-to-treat populations. The benefits of improved dose timing for long-term medication adherence require additional investigation. PMID:25504449

  2. Additivity of Pyrethroid Actions on Sodium Influx in Cerebrocortical Neurons in Primary Culture

    PubMed Central

    Cao, Zhengyu; Shafer, Timothy J.; Crofton, Kevin M.; Gennings, Chris

    2011-01-01

    Background: Pyrethroid insecticides bind to voltage-gated sodium channels and modify their gating kinetics, thereby disrupting neuronal function. Although previous work has tested the additivity of pyrethroids in vivo, this has not been assessed directly at the primary molecular target using a functional measure. Objectives: We investigated the potency and efficacy of 11 structurally diverse food-use pyrethroids to evoke sodium (Na+) influx in neurons and tested the hypothesis of dose additivity for a mixture of these same 11 compounds. Methods: We determined pyrethroid-induced increases in Na+ influx in primary cultures of cerebrocortical neurons using the Na+-sensitive dye sodium-binding benzofuran isophthalate (SBFI). Concentration-dependent responses for 11 pyrethroids were determined, and the response to dilutions of a mixture of all 11 compounds at an equimolar mixing ratio was assessed. Additivity was tested assuming a dose-additive model. Results: Seven pyrethroids produced concentration-dependent, tetrodotoxin-sensitive Na+ influx. The rank order of potency was deltamethrin > S-bioallethrin > β-cyfluthrin > λ-cyhalothrin > esfenvalerate > tefluthrin > fenpropathrin. Cypermethrin and bifenthrin produced modest increases in Na+ influx, whereas permethrin and resmethrin were inactive. When all 11 pyrethroids were present at an equimolar mixing ratio, their actions on Na+ influx were consistent with a dose-additive model. Conclusions: These data provide in vitro relative potency and efficacy measurements for 7 pyrethroid compounds in intact mammalian neurons. Despite differences in individual compound potencies, we found the action of a mixture of all 11 pyrethroids to be additive when we used an appropriate statistical model. These results are consistent with a previous report of the additivity of pyrethroids in vivo. PMID:21665567

  3. The Development of a Beta-Gamma Personnel Dosimeter

    NASA Astrophysics Data System (ADS)

    Tsakeres, Frank Steven

    The assessment of absorbed dose in mixed beta and gamma radiation fields is an extremely complex task. For many years, the assessment of the absorbed dose to tissue from the weakly penetrating components of a radiation field (i.e., beta particles, electrons) has been largely ignored. Beta radiation fields are encountered routinely in a nuclear facility and may represent the major radiation component under certain accident or emergency conditions. Many attempts have been made to develop an accurate mixed field personnel dosimeter. However, all of these dosimeters have exhibited numerous response problems which have limited their usefulness for personnel dose assessment. Consequently, the determination of the absorbed dose at the epidermal depth (i.e., 7 mg/cm('2)) has been difficult to measure accurately. The objective of this research project was to design, build, and test a sensitive and accurate personnel dosimeter for mixed field applications. The selection of the various dosimeter elements were determined by evaluating several types of phosphors, filters, and backscatter materials. After evaluating the various response characteristics of the badge components, a prototype dosimeter, the CHEMM (CaF(,2):Dy Highly Efficient Multiple Element Multiple Filter) personnel dosimeter, was developed and tested at Georgia Tech, Emory University and the National Bureau of Standards. This dosimeter was comprised of four large CaF(,2):Dy (TLD-200) TLD's and a standard LiF (TLD-100) chip. The weakly penetrating and penetrating components of a radiation field were separated using a series of TLD/filter combinations and a new dose assessment algorithm. The large TLD-200 chips, along with a series of tissue-equivalent filters, were used to determine the absorbed dose due to the weakly penetrating radiation while a LiF/filter combination was used to measure the penetrating component. In addition, a new backscatter material was included in the badge design to better simulate a tissue-equivalent response. The CHEMM personnel dosimeter performance tests were conducted to simulate actual mixed radiation field environments. This dosimeter provided a high degree of sensitivity with accuracies well within the ANSI recommended performance standards for personnel dosimeters. In addition, it was concluded that the CHEMM dosimetry system provided a practical dosimeter alternative with a higher dose assessment accuracy and measurement sensitivity than the personnel dosimetry systems presently used in the nuclear power industry.

  4. Dosimetric impact in the dose-volume histograms of rectal and vesical wall contouring in prostate cancer IMRT treatments.

    PubMed

    Gómez, Laura; Andrés, Carlos; Ruiz, Antonio

    2017-01-01

    The main purpose of this study was to evaluate the differences in dose-volume histograms of IMRT treatments for prostate cancer based on the delineation of the main organs at risk (rectum and bladder) as solid organs or by contouring their wall. Rectum and bladder have typically been delineated as solid organs, including the waste material, which, in practice, can lead to an erroneous assessment of the risk of adverse effects. A retrospective study was made on 25 patients treated with IMRT radiotherapy for prostate adenocarcinoma. 76.32 Gy in 36 fractions was prescribed to the prostate and seminal vesicles. In addition to the delineation of the rectum and bladder as solid organs (including their content), the rectal and bladder wall were also delineated and the resulting dose-volume histograms were analyzed for the two groups of structures. Data analysis shows statistically significant differences in the main parameters used to assess the risk of toxicity of a prostate radiotherapy treatment. Higher doses were received on the rectal and bladder walls compared to doses received on the corresponding solid organs. The observed differences in terms of received doses to the rectum and bladder based on the method of contouring could gain greater importance in inverse planning treatments, where the treatment planning system optimizes the dose in these volumes. So, one should take into account the method of delineating of these structures to make a clinical decision regarding dose limitation and risk assessment of chronic toxicity.

  5. Modelling PK/QT relationships from Phase I dose-escalation trials for drug combinations and developing quantitative risk assessments of clinically relevant QT prolongations.

    PubMed

    Sinclair, Karen; Kinable, Els; Grosch, Kai; Wang, Jixian

    2016-05-01

    In current industry practice, it is difficult to assess QT effects at potential therapeutic doses based on Phase I dose-escalation trials in oncology due to data scarcity, particularly in combinations trials. In this paper, we propose to use dose-concentration and concentration-QT models jointly to model the exposures and effects of multiple drugs in combination. The fitted models then can be used to make early predictions for QT prolongation to aid choosing recommended dose combinations for further investigation. The models consider potential correlation between concentrations of test drugs and potential drug-drug interactions at PK and QT levels. In addition, this approach allows for the assessment of the probability of QT prolongation exceeding given thresholds of clinical significance. The performance of this approach was examined via simulation under practical scenarios for dose-escalation trials for a combination of two drugs. The simulation results show that invaluable information of QT effects at therapeutic dose combinations can be gained by the proposed approaches. Early detection of dose combinations with substantial QT prolongation is evaluated effectively through the CIs of the predicted peak QT prolongation at each dose combination. Furthermore, the probability of QT prolongation exceeding a certain threshold is also computed to support early detection of safety signals while accounting for uncertainty associated with data from Phase I studies. While the prediction of QT effects is sensitive to the dose escalation process, the sensitivity and limited sample size should be considered when providing support to the decision-making process for further developing certain dose combinations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. 75 FR 24421 - Tebuconazole; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... Hearing Clerk as required by 40 CFR part 178 on or before July 6, 2010. In addition to filing an objection.... Effects on these target organs were seen in both rodent and non-rodent species. In addition, ocular... reference values for risk assessment. The POD may be defined as the highest dose at which no adverse effects...

  7. Technical Note: scuda: A software platform for cumulative dose assessment.

    PubMed

    Park, Seyoun; McNutt, Todd; Plishker, William; Quon, Harry; Wong, John; Shekhar, Raj; Lee, Junghoon

    2016-10-01

    Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (scuda) that can be seamlessly integrated into the clinical workflow. scuda consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

  8. Technical Note: SCUDA: A software platform for cumulative dose assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Seyoun; McNutt, Todd; Quon, Harry

    Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our imagemore » PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.« less

  9. The current state of knowledge on the use of the benchmark dose concept in risk assessment.

    PubMed

    Sand, Salomon; Victorin, Katarina; Filipsson, Agneta Falk

    2008-05-01

    This review deals with the current state of knowledge on the use of the benchmark dose (BMD) concept in health risk assessment of chemicals. The BMD method is an alternative to the traditional no-observed-adverse-effect level (NOAEL) and has been presented as a methodological improvement in the field of risk assessment. The BMD method has mostly been employed in the USA but is presently given higher attention also in Europe. The review presents a number of arguments in favor of the BMD, relative to the NOAEL. In addition, it gives a detailed overview of the several procedures that have been suggested and applied for BMD analysis, for quantal as well as continuous data. For quantal data the BMD is generally defined as corresponding to an additional or extra risk of 5% or 10%. For continuous endpoints it is suggested that the BMD is defined as corresponding to a percentage change in response relative to background or relative to the dynamic range of response. Under such definitions, a 5% or 10% change can be considered as default. Besides how to define the BMD and its lower bound, the BMDL, the question of how to select the dose-response model to be used in the BMD and BMDL determination is highlighted. Issues of study design and comparison of dose-response curves and BMDs are also covered. Copyright (c) 2007 John Wiley & Sons, Ltd.

  10. Acquisition and Retention of Sterile Compounding Accuracy Skills

    PubMed Central

    Brown, Michael C.; Valdovinos, Katie; Zavala, Pedro J.

    2017-01-01

    Objective. To determine the accuracy of dose of pharmacy students’ parenteral sterile preparation skills and to measure pharmacy students’ skill retention 1.5 years later. Methods. An exercise was designed to assess each student’s accuracy in compounding a sterile preparation with the correct potency during a second and then third year course. Results. Initially, the mean (standard deviation) of 141 students’ compounded preparation dose was not significantly different than the desired dose. Additionally, 91.5% of products were within 10% of the desired dose. In the follow-up activity the next academic year, the mean dose was not significantly different than the original compounded dose. Similarly 92.9% were within 10% of the desired dose. Conclusion. Students’ overall accuracy of sterile compounding was good initially and well-retained more than a year later, with more than 90% of students being within 10% of the desired dose in both courses. PMID:28970616

  11. Estimating the impact of grouping misclassification on risk prediction when using the relative potency factors method to assess mixtures risk -Presentation

    EPA Science Inventory

    Environmental health risk assessments of chemical mixtures that rely on component approaches often begin by grouping the chemicals of concern according to toxicological similarity. Approaches that assume dose addition typically are used for groups of similarly-acting chemicals an...

  12. Yellow Fever Vaccine Booster Doses: Recommendations of the Advisory Committee on Immunization Practices, 2015.

    PubMed

    Staples, J Erin; Bocchini, Joseph A; Rubin, Lorry; Fischer, Marc

    2015-06-19

    On February 26, 2015, the Advisory Committee on Immunization Practices (ACIP) voted that a single primary dose of yellow fever vaccine provides long-lasting protection and is adequate for most travelers. ACIP also approved recommendations for at-risk laboratory personnel and certain travelers to receive additional doses of yellow fever vaccine (Box). The ACIP Japanese Encephalitis and Yellow Fever Vaccines Workgroup evaluated published and unpublished data on yellow fever vaccine immunogenicity and safety. The evidence for benefits and risks associated with yellow fever vaccine booster doses was evaluated using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework. This report summarizes the evidence considered by ACIP and provides the updated recommendations for yellow fever vaccine booster doses.

  13. Dose commitments due to radioactive releases from nuclear power plant sites: Methodology and data base. Supplement 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, D.A.

    1996-06-01

    This manual describes a dose assessment system used to estimate the population or collective dose commitments received via both airborne and waterborne pathways by persons living within a 2- to 80-kilometer region of a commercial operating power reactor for a specific year of effluent releases. Computer programs, data files, and utility routines are included which can be used in conjunction with an IBM or compatible personal computer to produce the required dose commitments and their statistical distributions. In addition, maximum individual airborne and waterborne dose commitments are estimated and compared to 10 CFR Part 50, Appendix 1, design objectives. Thismore » supplement is the last report in the NUREG/CR-2850 series.« less

  14. Assessment of serum biomarkers in rats after exposure to pesticides of different chemical classes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moser, Virginia C., E-mail: Moser.ginger@epa.gov; Stewart, Nicholas; Freeborn, Danielle L.

    There is increasing emphasis on the use of biomarkers of adverse outcomes in safety assessment and translational research. We evaluated serum biomarkers and targeted metabolite profiles after exposure to pesticides (permethrin, deltamethrin, imidacloprid, carbaryl, triadimefon, fipronil) with different neurotoxic actions. Adult male Long–Evans rats were evaluated after single exposure to vehicle or one of two doses of each pesticide at the time of peak effect. The doses were selected to produce similar magnitude of behavioral effects across chemicals. Serum or plasma was analyzed using commercial cytokine/protein panels and targeted metabolomics. Additional studies of fipronil used lower doses (lacking behavioral effects),more » singly or for 14 days, and included additional markers of exposure and biological activity. Biomarker profiles varied in the number of altered analytes and patterns of change across pesticide classes, and discriminant analysis could separate treatment groups from control. Low doses of fipronil produced greater effects when given for 14 days compared to a single dose. Changes in thyroid hormones and relative amounts of fipronil and its sulfone metabolite also differed between the dosing regimens. Most cytokine changes reflected alterations in inflammatory responses, hormone levels, and products of phospholipid, fatty acid, and amino acid metabolism. These findings demonstrate distinct blood-based analyte profiles across pesticide classes, dose levels, and exposure duration. These results show promise for detailed analyses of these biomarkers and their linkages to biological pathways. - Highlights: • Pesticides typical of different classes produced distinct patterns of change in biomarker panels. • Based on the panels used, alterations suggest impacts on immune, metabolism, and homeostasis functions. • Some changes may reflect actions on neurotransmitter systems involved in immune modulation. • Fipronil effects on thyroid and kinetics differed with acute and repeated administration.« less

  15. Further assessment of the clinically effective dose range of etoricoxib: a randomized, double-blinded, placebo-controlled trial in rheumatoid arthritis.

    PubMed

    Greenwald, M; Peloso, P M; Mandel, D; Soto, O; Mehta, A; Frontera, N; Boice, J A; Zhan, X J; Curtis, S P

    2011-10-01

    To further assess the clinically active dose range of etoricoxib, a COX-2 selective inhibitor, in rheumatoid arthritis (RA). RA patients were randomized to etoricoxib 10, 30, 60, or 90 mg or placebo in a double-blind, 12-week study. DMARDs (methotrexate, biologics) or low-dose corticosteroids were allowed in stable doses. The primary endpoint was the proportion of patients completing the study and achieving an American College of Rheumatology 20% (ACR20) response. Secondary endpoints included individual components of the ACR index and Patient Global Assessment of Pain. Safety was assessed by physical exam and adverse experiences (AEs) occurrences. Etoricoxib 90 mg was the only dose to reach a statistically significant difference from placebo (p < 0.001) on the primary endpoint; etoricoxib 60 mg approached significance (p = 0.057). Significant pain improvement vs. placebo was observed with etoricoxib 90 mg (p < 0.001), 60 mg (p = 0.018), and 30 mg (p = 0.017). Despite the use of background biologics and corticosteroids, a dose response was still apparent. A higher proportion of etoricoxib 60 and 90 mg patients had renovascular AEs (i.e., edema and hypertension) compared with placebo, although discontinuations for renovascular AEs were rare. Etoricoxib 90 mg had a higher incidence of serious AEs (n = 5; 1 was considered drug-related) versus placebo (n = 0). The present study was not powered to detect differences in cardiovascular or gastrointestinal safety by dose. Additionally, further research is needed to clarify the role of doses less than the etoricoxib 90 mg dose for pain management in RA patients. Etoricoxib 90 mg demonstrated statistically superior efficacy (ACR20) compared with placebo and numerical superiority over the other doses of etoricoxib studied. Etoricoxib 30 and 60 mg demonstrated significant pain improvement versus placebo, suggesting utility for some patients.

  16. Human abuse liability assessment of oxycodone combined with ultra-low-dose naltrexone.

    PubMed

    Tompkins, David Andrew; Lanier, Ryan K; Harrison, Joseph A; Strain, Eric C; Bigelow, George E

    2010-07-01

    Prescription opioid abuse has risen dramatically in the United States as clinicians have increased opioid prescribing for alleviation of both acute and chronic pain. Opioid analgesics with decreased risk for abuse are needed. Preclinical and clinical studies have shown that opioids combined with ultra-low-dose naltrexone (NTX) may have increased analgesic potency and have suggested reduced abuse or dependence liability. This study addressed whether addition of ultra-low-dose naltrexone might decrease the abuse liability of oxycodone (OXY) in humans. This double-blind, placebo-controlled study systematically examined the subjective and physiological effects of combining oral OXY and ultra-low NTX doses in 14 experienced opioid abusers. Seven acute drug conditions given at least 5 days apart were compared in a within-subject crossover design: placebo, OXY 20 mg, OXY 40 mg, plus each of the active OXY doses combined with 0.0001 and 0.001 mg NTX. The methods were sensitive to detecting opioid effects on abuse liability indices, with significant differences between all OXY conditions and placebo as well as between 20 and 40 mg OXY doses on positive subjective ratings (e.g., "I feel a good drug effect" or "I like the drug"), on observer- and participant-rated opioid agonist effects, and on a drug-versus-money value rating. There were no significant differences or evident trends associated with the addition of either NTX dose on any abuse liability indices. The addition of ultra-low-dose NTX to OXY did not decrease abuse liability of acutely administered OXY in experienced opioid abusers.

  17. Twice-daily and three-times-daily dosing of a repaglinide/metformin fixed-dose combination tablet provide similar glycaemic control.

    PubMed

    Raskin, P; Lewin, A; Reinhardt, R; Lyness, W

    2009-10-01

    To assess the efficacy and safety of a new repaglinide/metformin fixed-dose combination (FDC) tablet administered either twice a day (BID) or three times a day (TID) for the management of type 2 diabetes. This was a 26-week, multicentre, open-label parallel trial in which subjects poorly controlled with mono- or dual-oral antidiabetic therapy were randomized 1 : 1 : 1 to instead receive repaglinide/metformin FDC either BID or TID or a rosiglitazone/metformin FDC BID. Two primary hypotheses were tested in a hierarchical manner: (i) treatment with the repaglinide/metformin FDC BID is non-inferior to that of the rosiglitazone/metformin FDC BID as measured by changes in haemoglobin A1c (HbA1c) (results presented in companion paper) and (ii) repaglinide/metformin BID is non-inferior to repaglinide/metformin TID (as measured by changes in HbA1c). Additional efficacy and safety end-points were also assessed. A total of 561 subjects were randomized; 383 completed the study. Repaglinide/metformin FDC BID was non-inferior to repaglinide/metformin FDC TID with respect to HbA1c. Additionally, changes in mean fasting plasma glucose values from baseline to end of study were not significantly different between the BID and the TID dose groups. There were no major hypoglycaemic episodes reported in either group during the trial, and overall adverse event profiles were similar. The efficacy of twice-daily dosing of a repaglinide/metformin FDC tablet was non-inferior to that of three-times-daily dosing.

  18. Assessment of the risk of solar ultraviolet radiation to amphibians. III. Prediction of impacts in selected northern midwestern wetlands.

    PubMed

    Diamond, Stephen A; Peterson, Gregory S; Tietge, Joseph E; Ankley, Gerald T

    2002-07-01

    Solar ultraviolet radiation, especially UVB (280-320 nm), has been hypothesized to be at least partially responsible for adverse effects (e.g., declines and malformations) in amphibian species throughout the world. Evaluation of this hypothesis has been limited by the paucity of high-quality UV dose-response data and reliable estimates of typical UV doses that occur in amphibian habitats. In this preliminary risk assessment for effects of UV radiation on amphibians, dose-response relationships quantified in outdoor experiments were compared with UV exposure estimates for 26 wetlands in northern Minnesota and Wisconsin. A comparison of wetland doses, derived from model prediction, historical data, and dissolved organic carbon (DOC) characterization, with experimental effects levels for green (R. clamitans), northern leopard (R. pipiens), and mink (R. septentrionalis) frogs indicated that the risk of mortality and malformations due to UV exposure is low for the majority of wetlands evaluated. Wetland UV dose, averaged over the entire breeding season, exceeded effects doses for mortality for all three species in two of the 26 wetlands examined and for one species in an additional wetland. On the basis of evidence that shorter term doses caused mortality in amphibian larvae, 3-day doses were also evaluated. In three of the wetlands examined, 3-day doses in excess of 85% of full sunlight (the level that appeared to trigger effects in controlled experimentation) occurred at frequencies ranging 22-100% for all three species and at frequencies ranging from 15% to 58% for R. pipiens and R. septentrionalis in three additional wetlands. Risk of malformation in R. pipiens was apparent in five of the 26 wetlands evaluated. Overall, estimated UVB doses in 21 of the wetlands never exceeded experimental effects doses for mortality or malformations. These results suggest that most amphibians are not currently at significant risk for UVB effects in northern Minnesota and Wisconsin wetlands. However, continued reduction of ozone and other global climate change effects may increase UV doses in wetlands, suggesting that the risk of UV to amphibians should continue to be monitored and studied.

  19. WE-AB-207B-06: Dose and Biological Uncertainties in Sarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marteinsdottir, M; University of Iceland, Reykjavik; Schuemann, J

    2016-06-15

    Purpose: To understand the clinical impact of key uncertainties in proton therapy potentially affecting the analysis of clinical trials, namely the assumption of using a constant relative biological effectiveness (RBE) of 1.1 compared to variable RBE for proton therapy and the use of analytical dose calculation (ADC) methods. Methods: Proton dose distributions were compared for analytical and Monte Carlo (TOPAS) dose calculations. In addition, differences between using a constant RBE of 1.1 (RBE-constant) were compared with four different RBE models (to assess model variations). 10 patients were selected from an ongoing clinical trial on IMRT versus scanned protons for sarcoma.more » Comparisons were performed using dosimetric indices based on dose-volume histogram analyses and γ-index analyses. Results: For three of the RBE-models the mean dose, D95, D50 and D02 (dose values covering 95%, 50% and 2% of the target volume, respectively) were up to 5% lower than for RBE-constant. The dosimetric indices for one of the RBE-models were around 9% lower than for the RBE-constant model. The differences for V90 (the percentage of the target volume covered by 90% of the prescription dose) were up to 40% for three RBE-models, whereas for one the difference was around 95%. All ADC dosimetric indices were up to 5% larger than for RBE-constant. The γ-index passing rate for the target volume with a 3%/3mm criterion was above 97% for all models except for one, which was below 24%. Conclusion: Interpretation of clinical trials on sarcoma may depend on dose calculation uncertainties (as assessed by Monte Carlo). In addition, the biological dose distribution depends notably on which RBE model is utilized. The current practice of using a constant RBE of 1.1 may overestimate the target dose by as much as 5% for biological dose calculations. Performing an RBE uncertainty analysis is recommended for trial analysis. U19 projects - U19 CA 021239. PI: Delaney.« less

  20. Locomotor activating effects of cocaine and scopolamine combinations in rats: isobolographic analysis

    PubMed Central

    Thomsen, Morgane

    2014-01-01

    Muscarinic cholinergic receptors are receiving renewed interest as viable targets for treating various psychiatric disorders. Dopaminergic and muscarinic systems interact in complex ways. The goal of this study was to quantify the interaction of a systemically administered psychomotor stimulant and muscarinic antagonist at the behavioral level. Using isobolographic analysis of locomotor activity data, we assessed the effects of three cocaine/scopolamine mixtures in terms of deviation from simple dose addition (additivity), at four effect levels. All three mixtures produced some more-than-additive (synergistic) effects, as lower doses were needed to produce given effects relative to the calculated effect of additive doses. A mixture with comparable contributions from cocaine and scopolamine produced significantly more-than-additive effects at all but the lowest effect level examined. A mostly-cocaine mixture was more-than-additive at low effect levels only, while a mostly-scopolamine mixture produced effects more consistent with additivity, with only the highest effect level barely reaching significant synergism. Our study confirms and quantifies previous findings that suggested synergistic effects of stimulants and muscarinic antagonists. The synergism implies that cocaine and scopolamine stimulate locomotor activity through non-identical pathways, and was most pronounced for a mixture containing cocaine and scopolamine in comparable proportions. PMID:24769455

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brock, K; Lee, C; Samuels, S

    Purpose: Tools are now available to perform daily dose assessment in radiotherapy, however, guidance is lacking as to when to replan to limit increase in normal tissue dose. This work performs statistical analysis to provide guidance for when adaptive replanning may be necessary for head/neck (HN) patients. Methods: Planning CT and daily kVCBCT images for 50 HN patients treated with VMAT were retrospectively evaluated. Twelve of 50 patients were replanned due to anatomical changes noted over their RT course. Daily dose assessment was performed to calculate the variation between the planned and delivered dose for the 38 patients not replannedmore » and the patients replanned using their delivered plan. In addition, for the replanned patients, the dose that would have been delivered if the plan was not modified was also quantified. Deviations in dose were analyzed before and after replanning, the daily variations in patients who were not replanned assessed, and the predictive power of the deviation after 1, 5, and 15 fractions determined. Results: Dose deviations were significantly reduced following replanning, compared to if the original plan would have been delivered for the entire course. Early deviations were significantly correlated with total deviations (p<0.01). Using the criteria that a 10% increase in the final delivered dose indicates a replan may be needed earlier in the treatment course, the following guidelines can be made with a 90% specificity after the first 5 fractions: deviations of 7% in the mean dose to the inferior constrictors and 5% in the mean dose to the parotid glands and submandibular glands. No significant dose deviations were observed in any patients for the CTV -70Gy (max deviation 4%). Conclusions: A 5–7% increase in mean dose to normal tissues within the first 5 fractions strongly correlate to an overall deviatios in the delivered dose for HN patients. This work is funded in part by NIH 2P01CA059827-16.« less

  2. CHOLINESTERASE INHIBITION AND HYPOTHERMIA FOLLOWING EXPOSURE TO BINARY MIXTURES OF ANTICHOLINESTERASE AGENTS: LACK OF EVIDENCE FOR CAUSE-AND-EFFECT

    EPA Science Inventory

    Dose-additivity has been the default assumption in risk assessments of pesticides with a common mechanism of action but it has been suspected that there could be non-additive effects. Inhibition of plasma cholinesterase (ChE) activity and hypothermia were used as benchmarks of e...

  3. Measuring and modeling of binary mixture effects of pharmaceuticals and nickel on cell viability/cytotoxicity in the human hepatoma derived cell line HepG2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudzok, S., E-mail: susanne.rudzok@ufz.d; Schlink, U., E-mail: uwe.schlink@ufz.d; Herbarth, O., E-mail: olf.herbarth@medizin.uni-leipzig.d

    2010-05-01

    The interaction of drugs and non-therapeutic xenobiotics constitutes a central role in human health risk assessment. Still, available data are rare. Two different models have been established to predict mixture toxicity from single dose data, namely, the concentration addition (CA) and independent action (IA) model. However, chemicals can also act synergistic or antagonistic or in dose level deviation, or in a dose ratio dependent deviation. In the present study we used the MIXTOX model (EU project ENV4-CT97-0507), which incorporates these algorithms, to assess effects of the binary mixtures in the human hepatoma cell line HepG2. These cells possess a liver-likemore » enzyme pattern and a variety of xenobiotic-metabolizing enzymes (phases I and II). We tested binary mixtures of the metal nickel, the anti-inflammatory drug diclofenac, and the antibiotic agent irgasan and compared the experimental data to the mathematical models. Cell viability was determined by three different methods the MTT-, AlamarBlue (registered) and NRU assay. The compounds were tested separately and in combinations. We could show that the metal nickel is the dominant component in the mixture, affecting an antagonism at low-dose levels and a synergism at high-dose levels in combination with diclofenac or irgasan, when using the NRU and the AlamarBlue assay. The dose-response surface of irgasan and diclofenac indicated a concentration addition. The experimental data could be described by the algorithms with a regression of up to 90%, revealing the HepG2 cell line and the MIXTOX model as valuable tool for risk assessment of binary mixtures for cytotoxic endpoints. However the model failed to predict a specific mode of action, the CYP1A1 enzyme activity.« less

  4. Decreased fetal hemoglobin over time among youth with sickle cell disease on hydroxyurea is associated with higher urgent hospital use.

    PubMed

    Green, Nancy S; Manwani, Deepa; Qureshi, Mahvish; Ireland, Karen; Sinha, Arpan; Smaldone, Arlene M

    2016-12-01

    Hydroxyurea (HU) induces dose-dependent increased fetal hemoglobin (HbF) for sickle cell disease (SCD). Large deviation from historical personal best (PBest) HbF, a clinic-based version of maximum dose, may identify a subset with suboptimal HU adherence over time. Retrospective clinical data from youth ages 10-18 years prescribed HU at two centers were extracted from medical records at three time points: pre-HU initiation, PBest and a recent assessment. Decrease from PBest HbF of 20% or more at recent assessment despite stable dosing was designated as high deviation from PBest. Acute hospital use was compared between 1-year periods, pre-HU and ±6 months for PBest and recent assessment. Groups were compared using descriptive and bivariate nonparametric statistics. Seventy-five youth, mean HU duration 5.9 years, met eligibility criteria. Mean ages of HU initiation, PBest and recent assessment were 8.0, 10.9 and 13.9 years, respectively. Despite stable dosing, average HbF of 19.5% at PBest overall declined by 31.8% at recent assessment. PBest HbF declined by 11.7 and 40.1% in two groups, the latter comprised 70.7% of the sample, had lower pre-HU and recent HbF and higher dosing. They experienced more urgent hospital use during the year framing recent assessment than during PBest; these findings were supported by sensitivity analysis. Decline from PBest HbF is a novel approach to assess HU effectiveness, is common among youth and may represent suboptimal adherence. Larger prospective studies using additional adherence measures are needed to confirm our approach of tracking HbF deviation over time and to define an appropriate cutoff. © 2016 Wiley Periodicals, Inc.

  5. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography.

    PubMed

    Treiber, O; Wanninger, F; Führ, H; Panzer, W; Regulla, D; Winkler, G

    2003-02-21

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  6. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography

    NASA Astrophysics Data System (ADS)

    Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.

    2003-02-01

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  7. Perinatal BPA exposure alters body weight and composition in a dose specific and sex specific manner: The addition of peripubertal exposure exacerbates adverse effects in female mice

    PubMed Central

    Rubin, Beverly S.; Paranjpe, Maneesha; DaFonte, Tracey; Schaeberle, Cheryl; Soto, Ana M.; Obin, Martin; Greenberg, Andrew S.

    2017-01-01

    Body weight (BW) and body composition were examined in CD-1 mice exposed perinatally or perinatally and peripubertally to 0, 0.25, 2.5, 25, or 250 μg BPA/kg BW/day. Our goal was to identify the BPA dose (s) and the exposure window(s) that increased BW and adiposity, and to assess potential sex differences in this response. Both perinatal exposure alone and perinatal plus peripubertal exposure to environmentally relevant levels of BPA resulted in lasting effects on body weight and body composition. The effects were dose specific and sex specific and were influenced by the precise window of BPA exposure. The addition of peripubertal BPA exposure following the initial perinatal exposure exacerbated adverse effects in the females but appeared to reduce differences in body weight and body composition between control and BPA exposed males. Some effects of BPA on body weight and body composition showed a non-linear dose response. PMID:27496714

  8. Meatballs with 3% and 6% dietary fibre from rye bran or pea fibre - Effects on sensory quality and subjective appetite sensations.

    PubMed

    Kehlet, Ursula; Pagter, Mette; Aaslyng, Margit D; Raben, Anne

    2017-03-01

    This study investigated dose-response effects of rye bran and pea fibre added to meatballs on sensory quality and subjective appetite sensations. Pea fibre or rye bran was added to meatballs in doses ranging from 3g to 6g dietary fibre per 100g. In a sensory profile, a trained panel (n=9) evaluated the meatballs in terms of odour, appearance, texture and flavour attributes. In a cross-over appetite study, 27 healthy men were served five test meals. Subjective appetite sensations were assessed over a 4-hour period. The addition of rye bran to the meatballs increased the grainy odour, texture and flavour. Pea fibre resulted in a more crumbly, firm and gritty texture with increasing doses of fibre. The sensory changes followed a dose-response relationship. Subjective appetite sensations were not affected by the addition of fibre. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Ocular allergy modulation to hi-dose antigen sensitization is a Treg-dependent process.

    PubMed

    Lee, Hyun Soo; Schlereth, Simona; Khandelwal, Payal; Saban, Daniel R

    2013-01-01

    A reproducible method to inhibit allergic immune responses is accomplished with hi-dose Ag sensitization, via intraperitoneal (IP) injection. However, the role of CD4+ CD25+ FoxP3+ T regulatory cells (Treg) in this process is unknown, as is whether such modulation extends to ocular allergy. We therefore determined herein whether hi-dose sensitization modulates ocular allergy, and whether CD4+ CD25+ FoxP3+ Treg are involved. C57BL/6 mice were IP sensitized via low-dose (100 µg) versus hi-dose (1000 µg) ovalbumin (OVA), in aluminum hydroxide (1 mg) and pertussis-toxin (300 ng). Other mice received anti-CD25 Ab (PC61) to ablate Treg during sensitization. In another experiment, Treg from hi-dose sensitized mice were adoptively transferred into low-dose sensitized mice. Once daily OVA challenges were administered. Clinical signs, IgE, T cell cytokines, and eosinophils were assessed. Data revealed that hi-dose, but not low-dose, sensitization led to allergy modulation, indicated by decreased clinical signs, serum IgE levels, Th2 recall responses, and eosinophil recruitment. T cells from hi-dose sensitized mice showed a robust increase in TGF-b production, and Treg from these mice were able to efficiently suppress effector T cell proliferation in vitro. In addition, in vivo Treg ablation in hi-dose sensitized mice revoked allergy modulation. Lastly, Treg from hi-dose sensitized mice were able to adoptively transfer allergy modulation to their low-dose sensitized counterparts. Collectively, these findings indicate that modulation to hi-dose sensitization, which is extended to ocular allergy, occurs in a Treg-dependent manner. In addition, our data suggest that hi-dose sensitization may henceforth facilitate the further examination of CD4+ CD25+ FoxP3+ Treg in allergic disease.

  10. Saw Palmetto for Symptom Management During Radiation Therapy for Prostate Cancer.

    PubMed

    Wyatt, Gwen K; Sikorskii, Alla; Safikhani, Abolfazl; McVary, Kevin T; Herman, James

    2016-06-01

    Lower urinary tract symptoms (LUTSs) affect 75%-80% of men undergoing radiation therapy (RT) for prostate cancer. To determine the safety, maximum tolerated dose (MTD), and preliminary efficacy of Serenoa repens commonly known as saw palmetto (SP) for management of LUTS during RT for prostate cancer. The dose finding phase used the time-to-event continual reassessment method to evaluate safety of three doses (320, 640, and 960 mg) of SP. Dose-limiting toxicities were assessed for 22 weeks using the Common Terminology Criteria for Adverse Events for nausea, gastritis, and anorexia. The exploratory randomized controlled trial phase assessed preliminary efficacy of the MTD against placebo. The primary outcome of LUTS was measured over 22 weeks using the International Prostate Symptom Score. Additional longitudinal assessments included quality of life measured with the Functional Assessment of Cancer Therapy-Prostate. The dose finding phase was completed by 27 men who reported no dose-limiting toxicities and with 20 participants at the MTD of 960 mg daily. The exploratory randomized controlled trial phase included 21 men, and no statistically significant differences in the International Prostate Symptom Score were observed. The prostate-specific concerns score of the Functional Assessment of Cancer Therapy-Prostate improved in the SP group (P = 0.03). Of 11 men in the placebo group, two received physician-prescribed medications to manage LUTS compared with none of the 10 men in the SP group. SP at 960 mg may be a safe herbal supplement, but its efficacy in managing LUTS during RT needs further investigation. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. Some considerations concerning the theory of combined toxicity: a case study of subchronic experimental intoxication with cadmium and lead.

    PubMed

    Varaksin, Anatoly N; Katsnelson, Boris A; Panov, Vladimir G; Privalova, Larisa I; Kireyeva, Ekaterina P; Valamina, Irene E; Beresneva, Olga Yu

    2014-02-01

    Rats were exposed intraperitoneally (3 times a week up to 20 injections) to either Cadmium and Lead salts in doses equivalent to their 0.05 LD50 separately or combined in the same or halved doses. Toxic effects were assessed by more than 40 functional, biochemical and morphometric indices. We analysed the results obtained aiming at determination of the type of combined toxicity using either common sense considerations based on descriptive statistics or two mathematical models based (a) on ANOVA and (b) on Mathematical Theory of Experimental Design, which correspond, respectively, to the widely recognised paradigms of effect additivity and dose additivity. Nevertheless, these approaches have led us unanimously to the following conclusions: (1) The above paradigms are virtually interchangeable and should be regarded as different methods of modelling the combined toxicity rather than as reflecting fundamentally differing processes. (2) Within both models there exist not merely three traditionally used types of combined toxicity (additivity, subadditivity and superadditivity) but at least 10 variants of it depending on exactly which effect is considered and on its level, as well as on the dose levels and their ratio. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Determinants of Hepatitis A Vaccine Immunity in a Cohort of Human Immunodeficiency Virus-Infected Children Living in Switzerland

    PubMed Central

    Crisinel, Pierre Alex; Posfay-Barbe, Klara Maria; Aebi, Christoph; Cheseaux, Jean-Jacques; Kahlert, Christian; Rudin, Christoph; Nadal, David

    2012-01-01

    Vaccination in HIV-infected children is often less effective than in healthy children. The goal of this study was to assess vaccine responses to hepatitis A virus (HAV) in HIV-infected children. Children of the Swiss Mother and Child HIV Cohort Study (MoCHiV) were enrolled prospectively. Recommendations for initial, catch-up, and additional HAV immunizations were based upon baseline antibody concentrations and vaccine history. HAV IgG was assessed by enzyme-linked immunosorbent assay (ELISA) with a protective cutoff value defined as ≥10 mIU/ml. Eighty-seven patients were included (median age, 11 years; range, 3.4 to 21.2 years). Forty-two patients were seropositive (48.3%) for HAV. Among 45 (51.7%) seronegative patients, 36 had not received any HAV vaccine dose and were considered naïve. Vaccine responses were assessed after the first dose in 29/35 naïve patients and after the second dose in 33/39 children (25 initially naïve patients, 4 seronegative patients, and 4 seropositive patients that had already received 1 dose of vaccine). Seroconversion was 86% after 1 dose and 97% after 2 doses, with a geometric mean concentration of 962 mIU/ml after the second dose. A baseline CD4+ T cell count below 750 cells/μl significantly reduced the post-2nd-dose response (P = 0.005). Despite a high rate of seroconversion, patients with CD4+ T cell counts of <750/μl had lower anti-HAV antibody concentrations. This may translate into a shorter protection time. Hence, monitoring humoral immunity may be necessary to provide supplementary doses as needed. PMID:22933400

  13. Pharmacokinetics and pharmacodynamics of the cathepsin S inhibitor, LY3000328, in healthy subjects.

    PubMed

    Payne, Christopher D; Deeg, Mark A; Chan, Melanie; Tan, Lai Hock; LaBell, Elizabeth Smith; Shen, Tong; DeBrota, David J

    2014-12-01

    The aim of this study was to assess the safety and tolerability, pharmacokinetics and pharmacodynamics of LY3000328 when administered as single escalating doses to healthy volunteers. This was a phase 1, placebo-controlled, dose escalation study with LY3000328 in 21 healthy male volunteers. Subjects were administered escalating LY3000328 doses up to 300 mg with food in this single dose study. Blood samples were collected at set times post-dose for the assessment of LY3000328 pharmacokinetics and the measurement of cathepsin S (CatS) activity, CatS mass and calculated CatS specific activity. All doses of LY3000328 were well tolerated, with linear pharmacokinetics up to the 300 mg dose. The pharmacodynamic activity of LY3000328 was measured ex vivo showing a biphasic response to LY3000328, where CatS activity declines, then returns to baseline, and then increases to a level above baseline. CatS mass was also assessed post-dose which increased in a dose-dependent manner, and continued to increase after LY3000328 had been cleared from the body. CatS specific activity was additionally calculated to normalize CatS activity for changes in CatS mass. This demonstrated the increase in CatS activity was attributable to the increase in CatS mass detected in plasma. A specific inhibitor of CatS which is cleared quickly from plasma may produce a transient decrease in plasma CatS activity which is followed by a more prolonged increase in plasma CatS mass which may have implications for the future clinical development of inhibitors of CatS. © 2014 The British Pharmacological Society.

  14. Pharmacokinetics and pharmacodynamics of the cathepsin S inhibitor, LY3000328, in healthy subjects

    PubMed Central

    Payne, Christopher D; Deeg, Mark A; Chan, Melanie; Tan, Lai Hock; LaBell, Elizabeth Smith; Shen, Tong; DeBrota, David J

    2014-01-01

    Aim The aim of this study was to assess the safety and tolerability, pharmacokinetics and pharmacodynamics of LY3000328 when administered as single escalating doses to healthy volunteers. Methods This was a phase 1, placebo-controlled, dose escalation study with LY3000328 in 21 healthy male volunteers. Subjects were administered escalating LY3000328 doses up to 300 mg with food in this single dose study. Blood samples were collected at set times post-dose for the assessment of LY3000328 pharmacokinetics and the measurement of cathepsin S (CatS) activity, CatS mass and calculated CatS specific activity. Results All doses of LY3000328 were well tolerated, with linear pharmacokinetics up to the 300 mg dose. The pharmacodynamic activity of LY3000328 was measured ex vivo showing a biphasic response to LY3000328, where CatS activity declines, then returns to baseline, and then increases to a level above baseline. CatS mass was also assessed post-dose which increased in a dose-dependent manner, and continued to increase after LY3000328 had been cleared from the body. CatS specific activity was additionally calculated to normalize CatS activity for changes in CatS mass. This demonstrated the increase in CatS activity was attributable to the increase in CatS mass detected in plasma. Conclusion A specific inhibitor of CatS which is cleared quickly from plasma may produce a transient decrease in plasma CatS activity which is followed by a more prolonged increase in plasma CatS mass which may have implications for the future clinical development of inhibitors of CatS. PMID:25039273

  15. Comparison of Points of Departure for Health Risk Assessment Based on High-Throughput Screening Data

    PubMed Central

    Sand, Salomon; Parham, Fred; Portier, Christopher J.; Tice, Raymond R.; Krewski, Daniel

    2016-01-01

    Background: The National Research Council’s vision for toxicity testing in the 21st century anticipates that points of departure (PODs) for establishing human exposure guidelines in future risk assessments will increasingly be based on in vitro high-throughput screening (HTS) data. Objectives: The aim of this study was to compare different PODs for HTS data. Specifically, benchmark doses (BMDs) were compared to the signal-to-noise crossover dose (SNCD), which has been suggested as the lowest dose applicable as a POD. Methods: Hill models were fit to > 10,000 in vitro concentration–response curves, obtained for > 1,400 chemicals tested as part of the U.S. Tox21 Phase I effort. BMDs and lower confidence limits on the BMDs (BMDLs) corresponding to extra effects (i.e., changes in response relative to the maximum response) of 5%, 10%, 20%, 30%, and 40% were estimated for > 8,000 curves, along with BMDs and BMDLs corresponding to additional effects (i.e., absolute changes in response) of 5%, 10%, 15%, 20%, and 25%. The SNCD, defined as the dose where the ratio between the additional effect and the difference between the upper and lower bounds of the two-sided 90% confidence interval on absolute effect was 1, 0.67, and 0.5, respectively, was also calculated and compared with the BMDLs. Results: The BMDL40, BMDL25, and BMDL18, defined in terms of extra effect, corresponded to the SNCD1.0, SNCD0.67, and SNCD0.5, respectively, at the median. Similarly, the BMDL25, BMDL17, and BMDL13, defined in terms of additional effect, corresponded to the SNCD1.0, SNCD0.67, and SNCD0.5, respectively, at the median. Conclusions: The SNCD may serve as a reference level that guides the determination of standardized BMDs for risk assessment based on HTS concentration–response data. The SNCD may also have application as a POD for low-dose extrapolation. Citation: Sand S, Parham F, Portier CJ, Tice RR, Krewski D. 2017. Comparison of points of departure for health risk assessment based on high-throughput screening data. Environ Health Perspect 125:623–633; http://dx.doi.org/10.1289/EHP408 PMID:27384688

  16. Identification of penetration path and deposition distribution of radionuclides in houses by experiments and numerical model

    NASA Astrophysics Data System (ADS)

    Hirouchi, Jun; Takahara, Shogo; Iijima, Masashi; Watanabe, Masatoshi; Munakata, Masahiro

    2017-11-01

    In order to lift of an evacuation order in evacuation areas and return residents to their homes, human dose assessments are required. However, it is difficult to exactly assess indoor external dose rate because the indoor distribution and infiltration pathways of radionuclides are unclear. This paper describes indoor and outdoor dose rates measured in eight houses in the difficult-to-return area in Fukushima Prefecture and identifies the distribution and main infiltration pathway of radionuclides in houses. In addition, it describes dose rates calculated with a Monte Carlo photon transport code to aid a thorough understanding of the measurements. The measurements and calculations indicate that radionuclides mainly infiltrate through visible openings such as vents, windows, and doors, and then deposit near these visible openings; however, they hardly infiltrate through sockets and air conditioning outlets. The measurements on rough surfaces such as bookshelves implies that radionuclides discharged from the Fukushima-Daiichi nuclear power plant did not deposit locally on rough surfaces.

  17. Image quality evaluation and patient dose assessment of medical fluoroscopic X-ray systems: a national study.

    PubMed

    Economides, S; Hourdakis, C J; Kalivas, N; Kalathaki, M; Simantirakis, G; Tritakis, P; Manousaridis, G; Vogiatzi, S; Kipouros, P; Boziari, A; Kamenopoulou, V

    2008-01-01

    This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm(-1). Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min(-1). Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min(-1).

  18. Radioactive impacts on nekton species in the Northwest Pacific and humans more than one year after the Fukushima nuclear accident.

    PubMed

    Men, Wu; Deng, Fangfang; He, Jianhua; Yu, Wen; Wang, Fenfen; Li, Yiliang; Lin, Feng; Lin, Jing; Lin, Longshan; Zhang, Yusheng; Yu, Xingguang

    2017-10-01

    This study investigated the radioactive impacts on 10 nekton species in the Northwest Pacific more than one year after the Fukushima Nuclear Accident (FNA) from the two perspectives of contamination and harm. Squids were especially used for the spatial and temporal comparisons to demonstrate the impacts from the FNA. The radiation doses to nekton species and humans were assessed to link this radioactivity contamination to possible harm. The total dose rates to nektons were lower than the ERICA ecosystem screening benchmark of 10μGy/h. Further dose-contribution analysis showed that the internal doses from the naturally occurring nuclide 210 Po were the main dose contributor. The dose rates from 134 Cs, 137 Cs, 90 Sr and 110m Ag were approximately three or four orders of magnitude lower than those from naturally occurring radionuclides. The 210 Po-derived dose was also the main contributor of the total human dose from immersion in the seawater and the ingestion of nekton species. The human doses from anthropogenic radionuclides were ~ 100 to ~ 10,000 times lower than the doses from naturally occurring radionuclides. A morbidity assessment was performed based on the Linear No Threshold assumptions of exposure and showed 7 additional cancer cases per 100,000,000 similarly exposed people. Taken together, there is no need for concern regarding the radioactive harm in the open ocean area of the Northwest Pacific. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    PubMed

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  20. A randomized two-by-two comparison of high-dose bolus tirofiban versus abciximab and unfractionated heparin versus bivalirudin during percutaneous coronary revascularization and stent placement: the tirofiban evaluation of novel dosing versus abciximab with clopidogrel and inhibition of thrombin (TENACITY) study trial.

    PubMed

    Moliterno, David J

    2011-06-01

    In the absence of high-dose thienopyridines, placebo-controlled trials have demonstrated a reduction in ischemic events with intravenous glycoprotein IIb/IIIa antagonists during percutaneous coronary intervention (PCI). One head-to-head trial comparing abciximab and tirofiban among PCI patients found tirofiban to be inferior, and laboratory evidence confirmed that the bolus dose of tirofiban tested in that trial to be less effective than abciximab. Whether a higher bolus dose of tirofiban would be as efficacious as abciximab during PCI is uncertain. Patients undergoing PCI were randomized equally to abciximab or to tirofiban, given as high-dose bolus (25 μg/kg) plus 12-hr infusion (0.15 μg/kg/min). All patients received aspirin and clopidogrel and were additionally randomized to unfractionated heparin or bivalirudin. Approximately 8,000 patients were to be studied, but after 383 were enrolled, the study sponsor discontinued the trial for financial reasons. The primary endpoint of 30-day death, myocardial infarction, or urgent target vessel revascularization occurred in 8.8% of patients randomized to abciximab and 6.9% of those randomized to tirofiban. The respective rates of major bleeding were 1.5 and 1.6%. Additionally, the primary endpoint occurred in 8.1% of patients randomized to unfractionated heparin and 7.6% of those randomized to bivalirudin. The respective rates of major bleeding were 2.5% and 0.5%. With limited assessment, this direct comparison of high-dose bolus tirofiban versus abciximab produced encouraging results and suggests that further study of this tirofiban dose regimen is warranted. The limited assessments comparing heparin and bivalirudin are consistent with prior observations. Copyright © 2010 Wiley-Liss, Inc.

  1. Assessing the possible radiological impact of routine radiological discharges from proposed nuclear power stations in England and Wales.

    PubMed

    Jones, Alison; Jones, Kelly; Holmes, Sheila; Ewers, Leon; Cabianca, Tiberio

    2013-03-01

    The aim of this work is to assess the possible radiological impact on the population of the United Kingdom (UK) from new nuclear power stations proposed for up to eight sites in England and Wales. The radiological impact was measured in terms of collective dose to the UK, European and world populations from a single year's discharge integrated to 500 and 100 000 years and the annual dose to an average member of the UK population (known as the per-caput dose). The doses were calculated for two reactor types, UK EPR™ and AP1000™, using the annual expected discharges estimated by the designers of the reactors and assuming two reactors per site. In addition, typical individual doses to adults living close to the sites were calculated on the basis of continuous discharges for 60 years (the assumed lifetime of the reactors). The dose to a representative person (previously known as the critical group) was not calculated, as this has been done elsewhere. The assessments were carried out using the software program PC-CREAM 08(®) which implements the updated European Commission methodology for assessing the radiological impact of routine releases of radionuclides to the environment. The collective dose truncated to 500 years to the UK population was estimated to be 0.5 manSv assuming UK EPR reactors on all sites and 0.6 manSv assuming AP1000s on three sites with UK EPRs on the other sites. The most significant contribution to the collective dose to the UK population is due to the global circulation of carbon-14 released to the atmosphere. The annual dose to an average member of the UK population from all sites was calculated to be around 10 nSv y(-1) and would therefore contribute little to an individual's total radiation dose. All the calculated doses to a typical adult living near the sites assuming continuous discharges for 60 years were found to be below 1 μSv y(-1).

  2. Ecological Dose Modeling of Aquatic and Riparian Receptors to Strontium-90 with an Emphasis on Radiosensitive Organs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poston, Ted M.; Traub, Richard J.; Antonio, Ernest J.

    2011-07-20

    The 100-NR-2 site is the location of elevated releases of strontium-90 to the Columbia River via contaminated groundwater. The resulting dose to aquatic and riparian receptors was evaluated in 2005 (DOE 2009) and compared to U.S. Department of Energy (DOE) dose guidance values. We have conducted additional dose assessments for a broader spectrum of aquatic and riparian organisms using RESRAD Biota and specific exposure scenarios. Because strontium-90 accumulates in bone, we have also modeled the dose to the anterior kidney, a blood-forming and immune system organ that lies close to the spinal column of fish. The resulting dose is primarilymore » attributable to the yttrium-90 progeny of strontium-90 and very little of the dose is associated with the beta emission from strontium-90. All dose modeling results were calculated with an assumption of secular equilibrium between strontium-90 and yttrum-90.« less

  3. An in vitro cytotoxic approach to assess the toxicity of heavy metals and their binary mixtures on hippocampal HT-22 cell line.

    PubMed

    Karri, Venkatanaidu; Kumar, Vikas; Ramos, David; Oliveira, Eliandre; Schuhmacher, Marta

    2018-01-05

    Humans are exposed to a cocktail of heavy metal toxicants in the environment. Though heavy metals are deleterious, there is a paucity of information on the toxicity of mixtures. In this study, four common neurotoxicity heavy metals lead (Pb) cadmium (Cd), arsenic (As), and methylmercury (MeHg) were exposed individually and as mixtures to HT-22 cell line for 8days. The study established that low dose exposures induced toxicity to the HT-22 cell line during 8days. The results indicates potency dependent response, the toxicity of single metals on the HT-22 cells; MeHg > As > Cd > Pb. The cytotoxicity data of single metals were used to determine the mixtures interaction profile by using the dose additivity and effect additivity method. Metal mixtures showed higher toxicities compared to individual metals. Synergistic, antagonistic or additive effects of the toxicity were observed in different mixtures in low dose exposure. The interactive responses of mixtures depend on the co-exposure metal and their respective concentration. We concluded that the combined effects should be considered in the risk assessment of heavy metal co-exposure and potency. In future, comprehensive mechanistic based investigations needed for understanding the real interactive mixtures effects at molecular level. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Organophosphates: Genetics Receptors and Antidotes.

    DTIC Science & Technology

    1986-08-01

    circumstances. Since muscarinic agonists, such as oxotremorine , are very poor inducers of seizures whereas nicotine is a potent inducer of such seizures, it...muscarinic agonist, oxotremorine (0.1 mg/kg), was assessed as was the response to a saline challenge. Responses were measured using a standard battery of...of naive animals to a 4 mg/kg dose of DFP, a 0.1 m,’ckg dose o oxotremorine , or saline, respectively. In addition, for all of these figures, solid

  5. Ovarian and endocrine responses in tropical sheep treated with reduced doses of cloprostenol.

    PubMed

    Contreras-Solis, Ignacio; Vasquez, B; Diaz, T; Letelier, C; Lopez-Sebastian, A; Gonzalez-Bulnes, A

    2009-09-01

    The present study aimed to assess the efficacy of reduced doses of cloprostenol for synchronizing estrus and ovulation in hair sheep. With the aim to evaluate the luteolytic activity of reduced cloprostenol doses, a first experiment was performed using a relatively large (group H: 126 microg; n=8), medium (group M: 68.25 microg; n=6) and small (group L: 38.5 microg; n=6) cloprostenol dose. Luteolysis was assessed at Days 3 and 6 after injection (Day 0) by progesterone concentrations (P(4)) and transrectal ultrasonography (US). In Experiment 2, sheep were randomly assigned to the same three doses to evaluate a protocol for estrous synchronization using two injections administered 9 days apart. A third trial was performed with ewes treated (9 days apart) with the large dose (H=126 microg; n=12) and with a small dose adjusted for facilitating volume management (LA=43.75 microg; n=12). Presence of estrous cycling was determined in all the ewes by US and P(4) assay, at Days -9, -6, -2, 0 (Day of second cloprostenol injection), 8 and 11. Bleeding and US were done every 4h from 16 h of the beginning of the estrus during the third trial to assess the preovulatory LH surge and timing of ovulation. Additionally, blood samples were drawn at Days 0, 1, 2 and 3 to assess estradiol (Experiments 2 and 3) and P(4) (Experiment 2) concentrations during the ovarian follicular phase. In all experiments, percentage of animals showing luteolysis, preovulatory follicular dynamics and function and percentage of ewes showing behavioral estrus in response to treatment was similar among groups. Timing of estrus for group H was earlier than group L (28.6+/-1.8h compared with 37.1+/-2.4h; P<0.05). In the third trial, the preovulatory LH peak was higher in the LA group than group H, in terms of maximum mean concentration during the surge (27.7+/-1.8 ng/mL compared with 21.3+/-2.2 ng/mL; P<0.05) and area under the curve (AUC; 183.4+/-12.7 ng/mL compared with 127.7+/-10.9 ng/mL; P<0.01). However, timing of ovulation was similar for H and LA groups. Thereafter, ovulation rate and luteal function at Day 11 were similar. Current results demonstrate that reduced doses of cloprostenol may be applied in a practical manner for reproductive management of sheep, with the additional advantage of reducing treatment costs.

  6. Ketamine as an adjuvant to opioids for cancer pain.

    PubMed

    Bell, Rae F; Eccleston, Christopher; Kalso, Eija A

    2017-06-28

    This is an update of a review first published in 2003 and updated in 2012.Ketamine is a commonly used anaesthetic agent, and in subanaesthetic doses is also given as an adjuvant to opioids for the treatment of refractory cancer pain, when opioids alone or in combination with appropriate adjuvant analgesics prove to be ineffective. Ketamine is known to have psychomimetic (including hallucinogenic), urological, and hepatic adverse effects. To determine the effectiveness and adverse effects of ketamine as an adjuvant to opioids for refractory cancer pain in adults. For this update, we searched MEDLINE (OVID) to December 2016. We searched CENTRAL (CRSO), Embase (OVID) and two clinical trial registries to January 2017. The intervention considered by this review was the addition of ketamine, given by any route of administration, in any dose, to pre-existing opioid treatment given by any route and in any dose, compared with placebo or active control. We included studies with a group size of at least 10 participants who completed the trial. Two review authors independently assessed the search results and performed 'Risk of bias' assessments. We aimed to extract data on patient-reported pain intensity, total opioid consumption over the study period; use of rescue medication; adverse events; measures of patient satisfaction/preference; function; and distress. We also assessed participant withdrawal (dropout) from trial. We assessed the quality of the evidence using GRADE (Grading of Recommendations Assessment, Development and Evaluation). One new study (185 participants) was identified by the updated search and included in the review. We included a total of three studies in this update.Two small studies, both with cross-over design, with 20 and 10 participants respectively, were eligible for inclusion in the original review. One study with 20 participants examined the addition of intrathecal ketamine to intrathecal morphine, compared with intrathecal morphine alone. The second study with 10 participants examined the addition of intravenous ketamine bolus in two different doses to ongoing morphine therapy, compared with placebo. Both of these studies reported reduction in pain intensity and reduction in morphine requirements when ketamine was added to opioid for refractory cancer pain. The new study identified by the updated search had a parallel group design and 185 participants. This placebo-controlled study examined rapid titration of subcutaneous ketamine to high dose (500 mg) in participants who were using different opioids. There were no differences between groups for patient-reported pain intensity.Pooling of the data from the three included trials was not appropriate because of clinical heterogeneity.The study examining intrathecal drug administration reported no adverse events related to ketamine. In the study using intravenous bolus administration, ketamine caused hallucinations in four of 10 participants. In the rapid dose escalation/high-dose subcutaneous ketamine study, there was almost twice the incidence of adverse events in the ketamine group, compared to the placebo group, with the most common adverse events being needle site irritation and cognitive disturbance. Two serious adverse events (bradyarrhythmia and cardiac arrest) thought to be related to ketamine were also reported in this trial.For all three studies there was an unclear risk of bias overall. Using GRADE, we judged the quality of the evidence to be very low due to study limitations and imprecision due to the small number of participants in all comparisons. Current evidence is insufficient to assess the benefits and harms of ketamine as an adjuvant to opioids for the relief of refractory cancer pain. The evidence was of very low quality, meaning that it does not provide a reliable indication of the likely effect, and the likelihood that the effect will be substantially different is high. Rapid dose escalation of ketamine to high dose (500 mg) does not appear to have clinical benefit and may be associated with serious adverse events. More randomised controlled trials (RCTs) examining specific low-dose ketamine clinical regimens in current use are needed.

  7. Delta/mu opioid receptor interactions in operant conditioning assays of pain-depressed responding and drug-induced rate suppression: assessment of therapeutic index in male Sprague Dawley rats.

    PubMed

    Cone, Katherine; Lanpher, Janell; Kinens, Abigail; Richard, Philomena; Couture, Sarah; Brackin, Rebecca; Payne, Emily; Harrington, Kylee; Rice, Kenner C; Stevenson, Glenn W

    2018-05-01

    Although delta/mu receptor interactions vary as a function of behavioral endpoint, there have been no assessments of these interactions using assays of pain-depressed responding. This is the first report of delta/mu interactions using an assay of pain-depressed behavior. A mult-cycle FR10 operant schedule was utilized in the presence of (nociception) and in the absence of (rate suppression) a lactic acid inflammatory pain-like manipulation. SNC80 and methadone were used as selective/high efficacy delta and mu agonists, respectively. Both SNC80 and methadone alone produced a dose-dependent restoration of pain-depressed responding and dose-dependent response rate suppression. Three fixed ratio mixtures, based on the relative potencies of the drugs in the nociception assay, also produced dose-dependent antinociception and sedation. Isobolographic analysis indicated that all three mixtures produced supra-additive antinociceptive effects and simply additive sedation effects. The therapeutic index (TI) inversely varied as a function of amount of SNC80 in the mixture, such that lower amounts of SNC80 produced a higher TI, and larger amounts produced a lower TI. Compared to literature using standard pain-elicited assays, the orderly relationship between SNC80 and TI reported here may be a unique function of assessing pain-depressed behavior.

  8. The Shigella human challenge model.

    PubMed

    Porter, C K; Thura, N; Ranallo, R T; Riddle, M S

    2013-02-01

    Shigella is an important bacterial cause of infectious diarrhoea globally. The Shigella human challenge model has been used since 1946 for a variety of objectives including understanding disease pathogenesis, human immune responses and allowing for an early assessment of vaccine efficacy. A systematic review of the literature regarding experimental shigellosis in human subjects was conducted. Summative estimates were calculated by strain and dose. While a total of 19 studies evaluating nine strains at doses ranging from 10 to 1 × 1010 colony-forming units were identified, most studies utilized the S. sonnei strain 53G and the S. flexneri strain 2457T. Inoculum solution and pre-inoculation buffering has varied over time although diarrhoea attack rates do not appear to increase above 75-80%, and dysentery rates remain fairly constant, highlighting the need for additional dose-ranging studies. Expansion of the model to include additional strains from different serotypes will elucidate serotype and strain-specific outcome variability.

  9. Effects of additional oxazepam in long-term users of oxazepam.

    PubMed

    Voshaar, Richard C Oude; Verkes, Robbert-Jan; van Luijtelaar, Gilles L J M; Edelbroek, Peter M; Zitman, Frans G

    2005-02-01

    Although additional dosages of benzodiazepines in long-term users of benzodiazepines are common, it is unknown whether these additional dosages resort any effect. The effects of an additional 20-mg dosage oxazepam were assessed in a double-blind, balanced-order, crossover randomized study comparing 16 long-term users of oxazepam (patients) with 18 benzodiazepine-naive controls (controls). The effects of 10 and 30 mg oxazepam were assessed at pretest and 2.5 hours after drug administration on: (a) saccadic eye movements as proxy for the sedative effect, (b) acoustic startle response (ASR) as proxy for the anxiolytic effects, (c) memory, (d) reaction time tasks, and (e) subjective measurements. Dose-related effects were found in patients on the peak velocity of saccadic eye movement and on response probability, respectively peak amplitude of the ASR. Comparison with controls, however, suggests that in patients the sedative effects might be mixed up with suppression of sedative withdrawal symptoms, whereas patients were as sensitive as benzodiazepine-naive controls for the effects of an additional dosage on the ASR. Neither 10 nor 30 mg oxazepam challenge affected the reaction time tasks in patients, whereas controls show a dose-related impairment. The memory impairing effects, however, did not differ significantly between patients and controls. In contrast to controls, patients could not discriminate between a 10- and 30-mg dosage as assessed by visual analogue scales and the STAI-DY-1, which might indicate a placebo effect in the 10-mg challenge in patients. We conclude that additional dosages of oxazepam still exert pronounced effects after daily use for more than 10 years.

  10. A 13-week dermal repeat-dose neurotoxicity study of hydrodesulfurized kerosene in rats.

    PubMed

    Breglia, Rudolph; Bui, Quang; Burnett, Donald; Koschier, Francis; Lapadula, Elizabeth; Podhasky, Paula; Schreiner, Ceinwen; White, Russell

    2014-01-01

    A 13-week dermal repeat-dose toxicity study was conducted with hydrodesulfurized (HDS) kerosene, a test material that also met the commercial specifications for aviation turbine fuel (jet A). The objectives were to assess the potential for target organ toxicity and neurotoxicity. The HDS kerosene was applied to the shaved backs of Sprague-Dawley CD rats, 12/sex/group, 6 h/d, 5 d/wk in doses of 0 (vehicle control), 165 mg/kg (20% HDS kerosene), 330 mg/kg (40% HDS kerosene), or 495 mg/kg (60% HDS kerosene). Additional rats (12/sex) from the control and the high-dose groups were held without treatment for 4 weeks to assess recovery. Standard parameters of toxicity were investigated during the in-life phase. At necropsy, organs were weighed and selected tissues were processed for microscopic evaluation. Neurobehavioral evaluations included tests of motor activity and functional observations that were conducted pretest, at intervals during the exposure period and after recovery. No test substance-related effects on mortality, clinical observations (except dermal irritation), body weight, or clinical chemistry values were observed. A dose-related increase in skin irritation, confirmed histologically as minimal, was evident at the dosing site. The only statistically significant change considered potentially treatment related was an increase in the neutrophil count in females at 13 weeks. No test article-related effects were observed in the neurobehavioral assessments or gross or microscopic findings in the peripheral or central nervous system tissues in any of the dose groups. Excluding skin irritation, the no observed adverse effect level value for all effects was considered 495 mg/kg/d.

  11. Anxiolytic effects of a combination of Melissa officinalis and Valeriana officinalis during laboratory induced stress.

    PubMed

    Kennedy, David O; Little, Wendy; Haskell, Crystal F; Scholey, Andrew B

    2006-02-01

    Melissa officinalis (lemon balm) and Valeriana officinalis (valerian) have been used both traditionally and contemporaneously as mild sedatives, anxiolytics and hypnotics. Recent research has suggested that both may attenuate laboratory induced stress. As the two herbs are most often sold in combination with each other the current study assessed the anxiolytic properties of such a combination during laboratory-induced stress. In this double-blind, placebo-controlled, randomized, balanced cross-over experiment, 24 healthy volunteers received three separate single doses (600 mg, 1200 mg, 1800 mg) of a standardized product containing M. officinalis and V. officinalis extracts, plus a placebo, on separate days separated by a 7 day wash out period. Modulation of mood and anxiety were assessed during pre-dose and 1 h, 3 h and 6 h post-dose completions of a 20 min version of the Defined Intensity Stressor Simulation (DISS) battery. Cognitive performance on the four concurrent tasks of the battery was also assessed. The results showed that the 600 mg dose of the combination ameliorated the negative effects of the DISS on ratings of anxiety. However, the highest dose (1800 mg) showed an increase in anxiety that was less marked but which reached significance during one testing session. In addition, all three doses led to decrements in performance on the Stroop task module within the battery, and the two lower doses led to decrements on the overall score generated on the DISS battery. These results suggest that a combination of Melissa officinalis and Valeriana officinalis possesses anxiolytic properties that deserve further investigation. Copyright 2006 John Wiley & Sons, Ltd.

  12. Developing and implementing a high precision setup system

    NASA Astrophysics Data System (ADS)

    Peng, Lee-Cheng

    The demand for high-precision radiotherapy (HPRT) was first implemented in stereotactic radiosurgery using a rigid, invasive stereotactic head frame. Fractionated stereotactic radiotherapy (SRT) with a frameless device was developed along a growing interest in sophisticated treatment with a tight margin and high-dose gradient. This dissertation establishes the complete management for HPRT in the process of frameless SRT, including image-guided localization, immobilization, and dose evaluation. The most ideal and precise positioning system can allow for ease of relocation, real-time patient movement assessment, high accuracy, and no additional dose in daily use. A new image-guided stereotactic positioning system (IGSPS), the Align RT3C 3D surface camera system (ART, VisionRT), which combines 3D surface images and uses a real-time tracking technique, was developed to ensure accurate positioning at the first place. The uncertainties of current optical tracking system, which causes patient discomfort due to additional bite plates using the dental impression technique and external markers, are found. The accuracy and feasibility of ART is validated by comparisons with the optical tracking and cone-beam computed tomography (CBCT) systems. Additionally, an effective daily quality assurance (QA) program for the linear accelerator and multiple IGSPSs is the most important factor to ensure system performance in daily use. Currently, systematic errors from the phantom variety and long measurement time caused by switching phantoms were discovered. We investigated the use of a commercially available daily QA device to improve the efficiency and thoroughness. Reasonable action level has been established by considering dosimetric relevance and clinic flow. As for intricate treatments, the effect of dose deviation caused by setup errors remains uncertain on tumor coverage and toxicity on OARs. The lack of adequate dosimetric simulations based on the true treatment coordinates from the treatment planning system (TPS) has limited adaptive treatments. A reliable and accurate dosimetric simulation using TPS and in-house software in uncorrected errors has been developed. In SRT, the calculated dose deviation is compared to the original treatment dose with the dose-volume histogram to investigate the dose effect of rotational errors. In summary, this work performed a quality assessment to investigate the overall accuracy of current setup systems. To reach the ideal HPRT, the reliable dosimetric simulation, an effective daily QA program and effective, precise setup systems were developed and validated.

  13. Additive anticonvulsant effects of agmatine and lithium chloride on pentylenetetrazole-induced clonic seizure in mice: involvement of α₂-adrenoceptor.

    PubMed

    Bahremand, Arash; Ziai, Pouya; Payandemehr, Borna; Rahimian, Reza; Amouzegar, Afsaneh; Khezrian, Mina; Montaser-Kouhsari, Laleh; Meibodi, Maryam Aghaei; Ebrahimi, Ali; Ghasemi, Abbas; Ghasemi, Mehdi; Dehpour, Ahmad Reza

    2011-09-01

    After 60 years, lithium is still the mainstay in the treatment of mood disorders and widely used in clinic. In addition to its mood stabilizer effects, lithium also shows some anticonvulsant properties. Similar to lithium, agmatine also plays a protective role in the CNS against seizures and has been reported to enhance the effect of different antiepileptic agents. Moreover, both agmatine and lithium have modulatory effects on α(2)-adrenoceptors. So, we designed this study: 1) to investigate whether agmatine and lithium show an additive effect against clonic seizures induced by pentylenetetrazole; 2) to assess whether this additive effect is mediated through the α(2)-adrenoceptor or not. In our study, acute administration of a single effective dose of lithium chloride (30 mg/kg, i.p.) increased the seizure threshold. Pre-treatment with low and, per se, non-effective doses of agmatine (1 and 3mg/kg) potentiated a sub-effective dose of lithium (10mg/kg). Interestingly, the anticonvulsant effects of these effective combinations of lithium and agmatine were prevented by pre-treatment with low and non-effective doses of yohimbine [α(2)-adrenoceptor antagonist] (0.1 and 0.5mg/kg). On the other hand, clonidine [α(2)-adrenoceptor agonist] augmented the anticonvulsant effect of a sub-effective combination of lithium (5mg/kg i.p.) and agmatine (1mg/kg) at relatively low doses (0.1 and 0.25mg/kg). In summary, our findings demonstrate that agmatine and lithium chloride exhibit additive anticonvulsant properties which seem to be mediated through α(2)-adrenoceptor. Copyright © 2011. Published by Elsevier B.V.

  14. IRIS Toxicological Review of Methanol (Noncancer) (Revised External Review Draft)

    EPA Science Inventory

    EPA is seeking additional public comment and external peer review of the scientific basis supporting the human health hazard and dose-response assessment of methanol (noncancer).

  1. Assessment of bioequivalence of rifampicin, isoniazid and pyrazinamide in a four drug fixed dose combination with separate formulations at the same dose levels.

    PubMed

    Agrawal, Shrutidevi; Kaur, Kanwal Jit; Singh, Inderjit; Bhade, Shantaram R; Kaul, Chaman Lal; Panchagnula, Ramesh

    2002-02-21

    Tuberculosis (TB) needs treatment with three to five different drugs simultaneously, depending on the patient category. These drugs can be given as single drug preparations or fixed dose combinations (FDCs) of two more drugs in a single formulation. World Health Organization and International Union against Tuberculosis and Lung Disease (IUATLD) recommend FDCs only of proven bioavailability. The relative bioavailability of rifampicin (RIF), isoniazid (INH) and pyrazinamide (PYZ) was assessed on a group of 13 healthy male subjects from a four drug FDC versus separate formulations at the same dose levels. The study was designed to be an open, crossover experiment. A total of nine blood samples each of 3 ml volume were collected over a period of 24-h. The concentrations of RIF, its main metabolite desacetyl RIF (DRIF), INH and PYZ in plasma were assessed by HPLC analysis. Pharmacokinetic parameters namely AUC(0-24), AUC(0-inf), C(max), T(max), were calculated and subjected to different statistical tests (Hauschke analysis, two way ANOVA, normal and log transformed confidence interval) at 90% confidence interval. In addition, elimination rate constant (K(el)) and absorption efficiencies for each drug were also calculated. It was concluded that four drugs FDC tablet is bioequivalent for RIF, INH and PYZ to separate formulation at the same dose levels.

  2. Dose response models and a quantitative microbial risk assessment framework for the Mycobacterium avium complex that account for recent developments in molecular biology, taxonomy, and epidemiology.

    PubMed

    Hamilton, Kerry A; Weir, Mark H; Haas, Charles N

    2017-02-01

    Mycobacterium avium complex (MAC) is a group of environmentally-transmitted pathogens of great public health importance. This group is known to be harbored, amplified, and selected for more human-virulent characteristics by amoeba species in aquatic biofilms. However, a quantitative microbial risk assessment (QMRA) has not been performed due to the lack of dose response models resulting from significant heterogeneity within even a single species or subspecies of MAC, as well as the range of human susceptibilities to mycobacterial disease. The primary human-relevant species and subspecies responsible for the majority of the human disease burden and present in drinking water, biofilms, and soil are M. avium subsp. hominissuis, M. intracellulare, and M. chimaera. A critical review of the published literature identified important health endpoints, exposure routes, and susceptible populations for MAC risk assessment. In addition, data sets for quantitative dose-response functions were extracted from published in vivo animal dosing experiments. As a result, seven new exponential dose response models for human-relevant species of MAC with endpoints of lung lesions, death, disseminated infection, liver infection, and lymph node lesions are proposed. Although current physical and biochemical tests used in clinical settings do not differentiate between M. avium and M. intracellulare, differentiating between environmental species and subspecies of the MAC can aid in the assessment of health risks and control of MAC sources. A framework is proposed for incorporating the proposed dose response models into susceptible population- and exposure route-specific QMRA models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    PubMed

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  4. Gastroprotective effects of arctigenin of Arctium lappa L. on a rat model of gastric ulcers

    PubMed Central

    Li, Xiao-Mei; Miao, Yu; Su, Qin-Yong; Yao, Jing-Chun; Li, Hong-Hua; Zhang, Gui-Min

    2016-01-01

    In the present study, the gastroprotective effects of arctigenin of Fructus Arctii were evaluated and the possible underlying mechanisms of action were elucidated. Arctigenin (high-performance liquid chromatography purity, >99.0%) was isolated and purified from the seeds of Arctium lappa L. The anti-ulcerogenic activity of arctigenin against ulcers induced by absolute ethanol and acetic acid was evaluated in a Sprague-Dawley rat model. In addition, the antioxidant activity was assessed by measuring malondialdehyde (MDA) levels in an ethanol-induced model and the anti-inflammatory effects were assessed by measuring five factors in an acetic acid-induced model. In the ethanol-induced model, arctigenin inhibited gastric lesions in a dose-dependent manner, by 53.04, 53.91 and 64.43% at doses of 0.05, 0.15 and 0.45 mg/kg, respectively. In addition, arctigenin reduced MDA (P<0.01) and increased superoxide dismutase (P<0.01) levels in serum when compared with the vehicle group. The lesion index induced by acetic acid was significantly inhibited by all doses of arctigenin (0.05, 0.15 and 0.45 mg/kg; P<0.01) in comparison to the vehicle group and in a dose-dependent manner. In addition, it was shown that the expression levels of tumor necrosis factor-α, interleukin-6 (IL-6), IL-10 and C-reactive protein were significantly decreased (P<0.05) in the arctigenin group compared with the vehicle group. Thus, the current study indicated that arctigenin exerted anti-ulcer activity, which may be associated with its reduction in oxidative and inflammatory damage. All the results indicate that arctigenin may be used as an effective therapeutic agent to prevent gastric ulcers. PMID:27882222

  5. Gastroprotective effects of arctigenin of Arctium lappa L. on a rat model of gastric ulcers.

    PubMed

    Li, Xiao-Mei; Miao, Yu; Su, Qin-Yong; Yao, Jing-Chun; Li, Hong-Hua; Zhang, Gui-Min

    2016-11-01

    In the present study, the gastroprotective effects of arctigenin of Fructus Arctii were evaluated and the possible underlying mechanisms of action were elucidated. Arctigenin (high-performance liquid chromatography purity, >99.0%) was isolated and purified from the seeds of Arctium lappa L. The anti-ulcerogenic activity of arctigenin against ulcers induced by absolute ethanol and acetic acid was evaluated in a Sprague-Dawley rat model. In addition, the antioxidant activity was assessed by measuring malondialdehyde (MDA) levels in an ethanol-induced model and the anti-inflammatory effects were assessed by measuring five factors in an acetic acid-induced model. In the ethanol-induced model, arctigenin inhibited gastric lesions in a dose-dependent manner, by 53.04, 53.91 and 64.43% at doses of 0.05, 0.15 and 0.45 mg/kg, respectively. In addition, arctigenin reduced MDA (P<0.01) and increased superoxide dismutase (P<0.01) levels in serum when compared with the vehicle group. The lesion index induced by acetic acid was significantly inhibited by all doses of arctigenin (0.05, 0.15 and 0.45 mg/kg; P<0.01) in comparison to the vehicle group and in a dose-dependent manner. In addition, it was shown that the expression levels of tumor necrosis factor-α, interleukin-6 (IL-6), IL-10 and C-reactive protein were significantly decreased (P<0.05) in the arctigenin group compared with the vehicle group. Thus, the current study indicated that arctigenin exerted anti-ulcer activity, which may be associated with its reduction in oxidative and inflammatory damage. All the results indicate that arctigenin may be used as an effective therapeutic agent to prevent gastric ulcers.

  6. A mixture of seven antiandrogens induces reproductive malformations in rats.

    EPA Science Inventory

    To date, regulatory agencies have not considered conducting cumulative risk assessments for mixtures of chemicals with diverse mechanisms of toxicity because it is assumed that the chemicals will act independently and the individual chemical doses are not additive. However, this ...

  7. Feasibility of dose enhancement assessment: Preliminary results by means of Gd-infused polymer gel dosimeter and Monte Carlo study.

    PubMed

    Santibáñez, M; Guillen, Y; Chacón, D; Figueroa, R G; Valente, M

    2018-04-11

    This work reports the experimental development of an integral Gd-infused dosimeter suitable for Gd dose enhancement assessment along with Monte Carlo simulations applied to determine the dose enhancement by radioactive and X-ray sources of interest in conventional and electronic brachytherapy. In this context, capability to elaborate a stable and reliable Gd-infused dosimeter was the first goal aimed at direct and accurate measurements of dose enhancement due to Gd presence. Dose-response was characterized for standard and Gd-infused PAGAT polymer gel dosimeters by means of optical transmission/absorbance. The developed Gd-infused PAGAT dosimeters demonstrated to be stable presenting similar dose-response as standard PAGAT within a linear trend up to 13 Gy along with good post-irradiation readout stability verified at 24 and 48 h. Additionally, dose enhancement was evaluated for Gd-infused PAGAT dosimeters by means of Monte Carlo (PENELOPE) simulations considering scenarios for isotopic and X-ray generator sources. The obtained results demonstrated the feasibility of obtaining a maximum enhancement around of (14 ± 1)% for 192 Ir source and an average enhancement of (70 ± 13)% for 241 Am. However, dose enhancement up to (267 ± 18)% may be achieved if suitable filtering is added to the 241 Am source. On the other hand, optimized X-ray spectra may attain dose enhancements up to (253 ± 22) %, which constitutes a promising future alternative for replacing radioactive sources by implementing electronic brachytherapy achieving high dose levels. Copyright © 2018. Published by Elsevier Ltd.

  8. The Effects of Low Dose Irradiation on Inflammatory Response Proteins in a 3D Reconstituted Human Skin Tissue Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varnum, Susan M.; Springer, David L.; Chaffee, Mary E.

    Skin responses to moderate and high doses of ionizing radiation include the induction of DNA repair, apoptosis, and stress response pathways. Additionally, numerous studies indicate that radiation exposure leads to inflammatory responses in skin cells and tissue. However, the inflammatory response of skin tissue to low dose radiation (<10 cGy) is poorly understood. In order to address this, we have utilized a reconstituted human skin tissue model (MatTek EpiDerm FT) and assessed changes in 23 cytokines twenty-four and forty eight hours following treatment of skin with either 3 or 10 cGy low-dose of radiation. Three cytokines, IFN-γ, IL-2, MIP-1α, weremore » significantly altered in response to low dose radiation. In contrast, seven cytokines were significantly altered in response to a high radiation dose of 200 cGy (IL-2, IL-10, IL-13, IFN-γ, MIP-1α, TNF α, and VEGF) or the tumor promoter 12-O-tetradecanoylphorbol 13-acetate (G-CSF, GM-CSF, IL-1α, IL-8, MIP-1α, MIP-1β, RANTES). Additionally, radiation induced inflammation appears to have a distinct cytokine response relative to the non-radiation induced stressor, TPA. Overall, these results indicate that there are subtle changes in the inflammatory protein levels following exposure to low dose radiation and this response is a sub-set of what is seen following a high dose in a human skin tissue model.« less

  9. DMLC tracking and gating can improve dose coverage for prostate VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colvill, E.; Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065; School of Physics, University of Sydney, NSW 2006

    2014-09-15

    Purpose: To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. Methods: A dose reconstruction method was used to retrospectively assess the dose distributions delivered without motion correction during volumetric modulated arc therapy fractions for 20 fractions of five prostate cancer patients who received conventionally fractionated radiotherapy. These delivered dose distributions were compared with the dose distributions which would have been delivered had DMLC tracking or gating motion correction strategies been implemented. The delivered dose distributions were constructed by incorporating themore » observed prostate motion with the patient's original treatment plan to simulate the treatment delivery. The DMLC tracking dose distributions were constructed using the same dose reconstruction method with the addition of MLC positions from Linac log files obtained during DMLC tracking simulations with the observed prostate motions input to the DMLC tracking software. The gating dose distributions were constructed by altering the prostate motion to simulate the application of a gating threshold of 3 mm for 5 s. Results: The delivered dose distributions showed that dosimetric effects of intrafraction prostate motion could be substantial for some fractions, with an estimated dose decrease of more than 19% and 34% from the planned CTVD{sub 99%} and PTV D{sub 95%} values, respectively, for one fraction. Evaluation of dose distributions for DMLC tracking and gating deliveries showed that both interventions were effective in improving the CTV D{sub 99%} for all of the selected fractions to within 4% of planned value for all fractions. For the delivered dose distributions the difference in rectum V{sub 65%} for the individual fractions from planned ranged from −44% to 101% and for the bladder V{sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.« less

  10. Efficacy and safety of the human anti-IL-1beta monoclonal antibody canakinumab in rheumatoid arthritis: results of a 12-week, phase II, dose-finding study

    PubMed Central

    2011-01-01

    Background Canakinumab is a fully human anti-interleukin IL-1beta monoclonal antibody, being investigated for the treatment of rheumatoid arthritis (RA). This multicenter, phase II, randomized, double-blind, placebo-controlled, parallel-group, dose-finding study investigated the efficacy and safety of canakinumab in patients with active RA despite ongoing therapy at stable doses of methotrexate. Methods Patients were randomized to receive one of four regimens, in addition to methotrexate, for 12 weeks: canakinumab 150 mg subcutaneously (SC) every 4 weeks (q4wk), canakinumab 300 mg SC (2 injections of 150 mg SC) every 2 weeks, a 600 mg intravenous loading dose of canakinumab followed by 300 mg SC every 2 weeks', or placebo SC every 2 weeks. Results Among 274 patients with evaluable efficacy data, the percentage of responders according to American College of Rheumatology 50 criteria (the primary endpoint, based on a 28-joint count) was significantly higher with canakinumab 150 mg SC q4wk than with placebo (26.5% vs. 11.4%, respectively; p = 0.028). Compared to placebo, this dosage of canakinumab was also associated with significantly more favorable responses at week 12 with respect to secondary endpoints including the Disease Activity Score 28, scores on the Health Assessment Questionnaire and Functional Assessment of Chronic Illness Therapy-Fatigue, swollen 28-joint count, and patient's and physician's global assessments of disease activity. No safety concerns were raised with canakinumab therapy, particularly with regard to infections. Few injection-site reactions occurred. Conclusion The addition of canakinumab 150 mg SC q4wk improves therapeutic responses among patients who have active RA despite stable treatment with methotrexate. Trial Registration (ClinicalTrials.gov identifier: NCT00784628) PMID:21736751

  11. Lack of effect of a booster dose of influenza vaccine in hemodialysis patients.

    PubMed

    Tanzi, Elisabetta; Amendola, Antonella; Pariani, Elena; Zappa, Alessandra; Colzani, Daniela; Logias, Franco; Perego, Angelo; Zanetti, Alessandro R

    2007-08-01

    To assess whether the administration of a booster dose of influenza vaccine may enhance immune response in hemodialysis patients, 58 subjects were given two doses of the 2003/2004 season influenza vaccine, 1 month apart. "European Agency for the Evaluation of Medicinal Products" (EMEA) criteria were fully met in terms of percentage of response and of mean-fold increase of hemagglutination inhibiting (HI) antibody titer, but not in terms of seroprotection rates (HI antibody titers > or =1:40). The second vaccine administration did not result in additional increase in seroprotection rate or in geometric mean titers. Protective immune response against the epidemic A/H3N2 Fujian-like strain, antigenically distant from that included in the vaccine (A/Panama/2007/99) was observed in 94.7% of vaccinees protected against the A/H3N2 vaccine strain 1 month after immunization. No adverse reactions were reported during follow-up. The study findings suggest that immune response to influenza vaccination may be suboptimal in hemodialysis patients and that the administration of an additional second dose of vaccine does not improve the humoral response.

  12. Perinatal BPA exposure alters body weight and composition in a dose specific and sex specific manner: The addition of peripubertal exposure exacerbates adverse effects in female mice.

    PubMed

    Rubin, Beverly S; Paranjpe, Maneesha; DaFonte, Tracey; Schaeberle, Cheryl; Soto, Ana M; Obin, Martin; Greenberg, Andrew S

    2017-03-01

    Body weight (BW) and body composition were examined in CD-1 mice exposed perinatally or perinatally and peripubertally to 0, 0.25, 2.5, 25, or 250μg BPA/kg BW/day. Our goal was to identify the BPA dose (s) and the exposure window(s) that increased BW and adiposity, and to assess potential sex differences in this response. Both perinatal exposure alone and perinatal plus peripubertal exposure to environmentally relevant levels of BPA resulted in lasting effects on body weight and body composition. The effects were dose specific and sex specific and were influenced by the precise window of BPA exposure. The addition of peripubertal BPA exposure following the initial perinatal exposure exacerbated adverse effects in the females but appeared to reduce differences in body weight and body composition between control and BPA exposed males. Some effects of BPA on body weight and body composition showed a non-linear dose response. Copyright © 2016. Published by Elsevier Inc.

  13. Chemical restraint and anaesthetic effects of a tiletamine-zolazepam/ketamine/detomidine combination in cattle.

    PubMed

    Re, Michela; Blanco-Murcia, Francisco J; Gómez de Segura, Ignacio A

    2011-10-01

    The immobilisation and anaesthesia of free-ranging cattle requires the administration of appropriate drugs in small volume via rifle or dart. The objective of this randomised controlled study was to test the capacity of a concentrated combination of tiletamine-zolazepam (TZ), ketamine (K) and detomidine (D) (TZKD) to immobilise/anaesthetise calves. Following administration of low, medium and high doses of TZKD to six healthy animals IM, the time-of-onset and duration of anaesthesia were recorded, in addition to standard cardio-respiratory parameters. Two noxious stimuli were applied to assess the analgesic effect of the combination. TZKD produced a dose-dependent anaesthetic action associated with respiratory depression and moderate hypoxaemia. Total recumbency lasted from 1h (with low dose) to 2h (with medium and high doses). The findings indicate that TZKD induces anaesthesia in calves, suitable not only for animal immobilisation, but also to carry out minor surgical procedures with or without additional local analgesia. Respiratory depression was the most severe side-effect and careful patient monitoring is recommended when using this drug combination. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. The effects of slice thickness and radiation dose level variations on computer-aided diagnosis (CAD) nodule detection performance in pediatric chest CT scans

    NASA Astrophysics Data System (ADS)

    Emaminejad, Nastaran; Lo, Pechin; Ghahremani, Shahnaz; Kim, Grace H.; Brown, Matthew S.; McNitt-Gray, Michael F.

    2017-03-01

    For pediatric oncology patients, CT scans are performed to assess treatment response and disease progression. CAD may be used to detect lung nodules which would reflect metastatic disease. The purpose of this study was to investigate the effects of reducing radiation dose and varying slice thickness on CAD performance in the detection of solid lung nodules in pediatric patients. The dataset consisted of CT scans of 58 pediatric chest cases, from which 7 cases had lung nodules detected by radiologist, and a total of 28 nodules were marked. For each case, the original raw data (sinogram data) was collected and a noise addition model was used to simulate reduced-dose scans of 50%, 25% and 10% of the original dose. In addition, the original and reduced-dose raw data were reconstructed at slice thicknesses of 1.5 and 3 mm using a medium sharp (B45) kernel; the result was eight datasets (4 dose levels x 2 thicknesses) for each case An in-house CAD tool was applied on all reconstructed scans, and results were compared with the radiologist's markings. Patient level mean sensitivities at 3mm thickness were 24%, 26%, 25%, 27%, and at 1.5 mm thickness were 23%, 29%, 35%, 36% for 10%, 25%, 50%, and 100% dose level, respectively. Mean FP numbers were 1.5, 0.9, 0.8, 0.7 at 3 mm and 11.4, 3.5, 2.8, 2.8 at 1.5 mm thickness for 10%, 25%, 50%, and 100% dose level respectively. CAD sensitivity did not change with dose level for 3mm thickness, but did change with dose for 1.5 mm. False Positives increased at low dose levels where noise values were high.

  15. Evaluation of radiation doses and associated risk from the Fukushima nuclear accident to marine biota and human consumers of seafood

    PubMed Central

    Fisher, Nicholas S.; Beaugelin-Seiller, Karine; Hinton, Thomas G.; Baumann, Zofia; Madigan, Daniel J.; Garnier-Laplace, Jacqueline

    2013-01-01

    Radioactive isotopes originating from the damaged Fukushima nuclear reactor in Japan following the earthquake and tsunami in March 2011 were found in resident marine animals and in migratory Pacific bluefin tuna (PBFT). Publication of this information resulted in a worldwide response that caused public anxiety and concern, although PBFT captured off California in August 2011 contained activity concentrations below those from naturally occurring radionuclides. To link the radioactivity to possible health impairments, we calculated doses, attributable to the Fukushima-derived and the naturally occurring radionuclides, to both the marine biota and human fish consumers. We showed that doses in all cases were dominated by the naturally occurring alpha-emitter 210Po and that Fukushima-derived doses were three to four orders of magnitude below 210Po-derived doses. Doses to marine biota were about two orders of magnitude below the lowest benchmark protection level proposed for ecosystems (10 µGy⋅h−1). The additional dose from Fukushima radionuclides to humans consuming tainted PBFT in the United States was calculated to be 0.9 and 4.7 µSv for average consumers and subsistence fishermen, respectively. Such doses are comparable to, or less than, the dose all humans routinely obtain from naturally occurring radionuclides in many food items, medical treatments, air travel, or other background sources. Although uncertainties remain regarding the assessment of cancer risk at low doses of ionizing radiation to humans, the dose received from PBFT consumption by subsistence fishermen can be estimated to result in two additional fatal cancer cases per 10,000,000 similarly exposed people. PMID:23733934

  16. Clinical assessment of the jaw-tracking function in IMRT for a brain tumor

    NASA Astrophysics Data System (ADS)

    Kim, Jin-Young; Kim, Shin-Wook; Choe, Bo-Young; Suh, Tae-Suk; Park, Sung-Kwang; Jo, Sun-Mi; Oh, Won-Yong; Shin, Jung-Wook; Cho, Gyu-Seok; Nam, Sang-Hee; Chung, Jin-Beom; Kim, Jung-Ki; Lee, Young-Kyu

    2015-01-01

    Intensity-modulated radiotherapy (IMRT) improves dose conformity and saves critical organs. IMRT is widely used in cases of head and neck, prostate, and brain cancer due to the close location of the targets to critical structures. However, because IMRT has a larger amount of radiation exposure than 3 dimensional-conformal radiation therapy (3D-CRT), it has disadvantages such as increases in the low dose irradiation to normal tissues and in the accumulated dose for the whole volume due to leakage and transmission of the multi-leaf collimator (MLC). The increased accumulated dose and the larger low dose may increase the occurrence of secondary malignant neoplasms. For these reasons, the jaw-tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and the transmission dose of the MLC with linear accelerators. However, the change in the superficial dose has not been verified with a quantitative analysis of the dose reduction in a brain tumor. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw-tracking function for a brain tumor by comparing treatment plans and superficial doses. To accomplish this, we made three types of original treatment plans using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) farther than 2 cm from the organs at risk (OAR); 2) within 2 cm of the OAR; and 3) intersecting with the OAR. Jaw-tracking treatment plans were also made with copies of the original treatment plan using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the original treatment plans and jaw-tracking treatment plans was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In addition, the dependencies of the effects of transmission and the scattering doses according to jaw motion were assessed through the difference in the surface doses. In the DVH comparison, a maximum dose difference of 0.4% was observed between the planning methods in the case of over 2 cm distance, and the maximum dose of 0.6% was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum dose difference of 2.3% was achieved. According to these results, the differences in the mean doses and the maximum doses to the OARs ware larger when the OARs and the planning target volume (PTV) were closer. In addition, small differences in the surface dose measurements were observed. In the case of the inside field, the differences were under 2% of the prescription dose while the difference was under 0.1% in the case of the outside field. Therefore, treatment plans with the jaw-tracking function consistently affected the dose reduction for a brain tumor, and the clinical possibility could be verified as the surface dose was not increased.

  17. SU-F-J-178: A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolly, S; Mutic, S; Anastasio, M

    Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework wasmore » developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.« less

  18. Estimation of Radiation Dose for a Sitting Phantom Using PIMAL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akkurt, Hatice; Eckerman, Keith F

    2007-01-01

    To assess the radiation dose in different configurations when needed (e.g., occupational exposure or public exposure in a radiologically significant event), the mathematical phantom has recently been revised to enable freely moving abilities for arms and legs. The revised phantom is called PIMAL: Phantom with Moving Arms and Legs. Additionally, a graphical user interface has been developed to assist the analyst with input preparation and output manipulation. To investigate the impact of the phantom configuration on the estimated organ doses, PIMAL has been used in a different posture than the standard vertical-upright position. In this paper, the estimated organ andmore » effective dose values for a representative posture, the phantom in a sitting position, compared with those for the phantom in standing position, are presented.« less

  19. Radioactive Waste Management Complex performance assessment: Draft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.

    1990-06-01

    A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Resultsmore » of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations.« less

  20. Tactile massage reduces rescue doses for pain and anxiety: an observational study.

    PubMed

    Pedersen, Karina; Björkhem-Bergman, Linda

    2018-03-01

    The aim of this study was to evaluate the effect of tactile massage (TM) on palliative care patients. An observational study at a hospice ward in Sweden was carried out. Forty-one palliative patients were offered TM, at an average of three treatments per patient. Before and after every treatment, self-assessed pain, well-being and anxiety according to the Edmonton Symptom Assessment Scale (0-10) were recorded. In addition, the number of rescue doses for pain and anxiety was monitored 24 hours before and after the treatment and in two consecutive days before the patients were offered TM (control data). TM resulted in improvement of self-assessed pain by 1.7 points (SD 1.6), anxiety by 2.3 points (SD 2.0) and well-being by 2.6 points (SD 1.4). The number of rescue doses for pain was reduced from 1.6 to 0.84 doses/patient (P<0.001) and for anxiety from 0.52 to 0.24 doses/patient (P<0.01). The number of rescue doses was not changed in the same patients in two consecutive days before the patients were offered TM. The effect was evident already after the first treatment and did not increase further with repeated treatments. No patients reported any harmful effects of the treatment. TM reduced the need for administration of rescue doses for pain and anxiety and improved well-being in palliative care patients. Larger randomised studies with parallel control groups are needed to confirm the findings from this observational pilot study. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Dose Assessment of Los Alamos National Laboratory-Derived Residual Radionuclides in Soils within Tract A-18-2 for Land Conveyance and Transfer Decisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruedig, Elizabeth; Whicker, Jeffrey Jay

    In 2017, soil sampling for radiological materials was conducted within Tract A-18-2 specifically for land conveyance decisions. Measurements of radionuclides in soil samples were evaluated against a recreational use scenario, and all measurements were below screening action levels for each radionuclide. The total estimated dose was less than 1 mrem/y (< 10 μSv/y) for a hypothetical recreational user (compared to a dose limit of 25 mrem/y (250 μSv/y)). Dose estimates were based on the 95% upper confidence limits for radionuclide concentrations within the Tract. Additionally, dose estimates less than 3 mrem/y are considered to be As Low As Reasonably Achievable,more » so no follow-up analysis was conducted. Release of this property is consistent with the requirements of DOE Order 458.1 and Policy 412.« less

  2. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    PubMed

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  3. Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control.

    PubMed

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Daioku, Tomihiko; Toyama, Hiroshi; Kato, Ryoichi

    2017-05-01

    Adequate dose management during computed tomography is important. In the present study, the dosimetric application software ImPACT was added to a functional calculator of the size-specific dose estimate and was part of the scan settings for the auto exposure control (AEC) technique. This study aimed to assess the practicality and accuracy of the modified ImPACT software for dose estimation. We compared the conversion factors identified by the software with the values reported by the American Association of Physicists in Medicine Task Group 204, and we noted similar results. Moreover, doses were calculated with the AEC technique and a fixed-tube current of 200 mA for the chest-pelvis region. The modified ImPACT software could estimate each organ dose, which was based on the modulated tube current. The ability to perform beneficial modifications indicates the flexibility of the ImPACT software. The ImPACT software can be further modified for estimation of other doses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Considering the cumulative risk of mixtures of chemicals – A challenge for policy makers

    PubMed Central

    2012-01-01

    Background The current paradigm for the assessment of the health risk of chemical substances focuses primarily on the effects of individual substances for determining the doses of toxicological concern in order to inform appropriately the regulatory process. These policy instruments place varying requirements on health and safety data of chemicals in the environment. REACH focuses on safety of individual substances; yet all the other facets of public health policy that relate to chemical stressors put emphasis on the effects of combined exposure to mixtures of chemical and physical agents. This emphasis brings about methodological problems linked to the complexity of the respective exposure pathways; the effect (more complex than simple additivity) of mixtures (the so-called 'cocktail effect'); dose extrapolation, i.e. the extrapolation of the validity of dose-response data to dose ranges that extend beyond the levels used for the derivation of the original dose-response relationship; the integrated use of toxicity data across species (including human clinical, epidemiological and biomonitoring data); and variation in inter-individual susceptibility associated with both genetic and environmental factors. Methods In this paper we give an overview of the main methodologies available today to estimate the human health risk of environmental chemical mixtures, ranging from dose addition to independent action, and from ignoring interactions among the mixture constituents to modelling their biological fate taking into account the biochemical interactions affecting both internal exposure and the toxic potency of the mixture. Results We discuss their applicability, possible options available to policy makers and the difficulties and potential pitfalls in implementing these methodologies in the frame of the currently existing policy framework in the European Union. Finally, we suggest a pragmatic solution for policy/regulatory action that would facilitate the evaluation of the health effects of chemical mixtures in the environment and consumer products. Conclusions One universally applicable methodology does not yet exist. Therefore, a pragmatic, tiered approach to regulatory risk assessment of chemical mixtures is suggested, encompassing (a) the use of dose addition to calculate a hazard index that takes into account interactions among mixture components; and (b) the use of the connectivity approach in data-rich situations to integrate mechanistic knowledge at different scales of biological organization. PMID:22759500

  5. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  6. Hypertension prevalence and living conditions related to air pollution: results of a national epidemiological study in Lebanon.

    PubMed

    Salameh, Pascale; Chahine, Mirna; Hallit, Souheil; Farah, Rita; Zeidan, Rouba Karen; Asmar, Roland; Hosseiny, Hassan

    2018-04-01

    Hypertension is a risk factor of several diseases, linked to high mortality and morbidity, particularly in developing countries. Some studies have linked indoor and outdoor pollution exposure items to hypertension, but results were inconsistent. Our objective was to assess the association of living conditions related to air pollution to hypertension in Lebanon, a Middle Eastern country. A national cross-sectional study was conducted all over Lebanon. Blood pressure and its related medications were assessed to be able to classify participants as hypertensive or not. Moreover, in addition to living conditions related to air pollution exposure, we assessed potential predictors of hypertension, including sociodemographic characteristics, self-reported health information and biological measurements. Furthermore, we assessed dose-effect relationship of air pollution items in relation with hypertension. Living conditions related to indoor and outdoor air pollution exposures were associated with hypertension, with or without taking biological values into account. Moreover, we found a dose-effect relationship of exposure with risk of disease (15% increase in risk of disease for every additional pollution exposure item), after adjustment for sociodemographics and biological characteristics (Ora = 1.15 [1.03-1.28]). Although additional studies would be necessary to confirm these findings, interventions should start to sensitize the population about the effect of air pollution on chronic diseases. The work on reducing pollution and improving air quality should be implemented to decrease the disease burden on the population and health system.

  7. Preclinical safety assessment of the 5-HT2A receptor agonist PET radioligand [ 11C]Cimbi-36.

    PubMed

    Ettrup, Anders; Holm, Søren; Hansen, Martin; Wasim, Muhammad; Santini, Martin Andreas; Palner, Mikael; Madsen, Jacob; Svarer, Claus; Kristensen, Jesper Langgaard; Knudsen, Gitte Moos

    2013-08-01

    [11C]Cimbi-36 was recently developed as an agonist radioligand for brain imaging of serotonin 2A receptors (5-HT2A) with positron emission tomography (PET). This may be used to quantify the high-affinity state of 5-HT2A receptors and may have the potential to quantify changes in cerebral 5-HT levels in vivo. We here investigated safety aspects related to clinical use of [11C]Cimbi-36, including radiation dosimetry and in vivo pharmacology. [11C]Cimbi-36 was injected in rats or pigs, and radiation dosimetry was examined by ex vivo dissection or with PET scanning, respectively. Based on animal data, the Organ Level INternal Dose Assessment software was used to estimate extrapolated human dosimetry for [11C]Cimbi-36. The 5-HT2A receptor agonist actions of [11C]Cimbi-36 in vivo pharmacological effects in mice elicited by increasing doses of Cimbi-36 were assessed with the head-twitch response (HTR). The effective dose as extrapolated from both rat and pig data was low, 7.67 and 4.88 μSv/MBq, respectively. In addition, the estimated absorbed radiation dose to human target organs did not exceed safety levels. Administration of 0.5 mg/kg Cimbi-36 leads to significant HTR compared to saline, whereas 0.05 mg/kg Cimbi-36 (doses much larger than those given in conjunction with a PET scan) did not elicit a significant HTR. Administration of tracer doses of [11C]Cimbi-36 does not seem to be associated with unusual radiation burden or adverse clinical effects.

  8. Assessing dose of the representative person for the purpose of radiation protection of the public. ICRP publication 101. Approved by the Commission in September 2005.

    PubMed

    2006-01-01

    The Commission intended that its revised recommendations should be based on a simple, but widely applicable, system of protection that would clarify its objectives and provide a basis for the more formal systems needed by operating managers and regulators. The recommendations would establish quantified constraints, or limits, on individual dose from specified sources. These dose constraints apply to actual or representative people who encounter occupational, medical, and public exposures. This report updates the previous guidance for estimating dose to the public. Dose to the public cannot be measured directly and, in some cases, it cannot be measured at all. Therefore, for the purpose of protection of the public, it is necessary to characterise an individual, either hypothetical or specific, whose dose can be used for determining compliance with the relevant dose constraint. This individual is defined as the 'representative person'. The Commission's goal of protection of the public is achieved if the relevant dose constraint for this individual for a single source is met and radiological protection is optimised. This report explains the process of estimating annual dose and recognises that a number of different methods are available for this purpose. These methods range from deterministic calculations to more complex probabilistic techniques. In addition, a mixture of these techniques may be applied. In selecting characteristics of the representative person, three important concepts should be borne in mind: reasonableness, sustainability, and homogeneity. Each concept is explained and examples are provided to illustrate their roles. Doses to the public are prospective (may occur in the future) or retrospective (occurred in the past). Prospective doses are for hypothetical individuals who may or may not exist in the future, while retrospective doses are generally calculated for specific individuals. The Commission recognises that the level of detail afforded by its provision of dose coefficients for six age categories is not necessary in making prospective assessments of dose, given the inherent uncertainties usually associated with estimating dose to the public and with identification of the representative person. It now recommends the use of three age categories for estimating annual dose to the representative person for prospective assessments. These categories are 0-5 years (infant), 6-15 years (child), and 16-70 years (adult). For practical implementation of this recommendation, dose coefficients and habit data for a 1-year-old infant, a 10-year-old child, and an adult should be used to represent the three age categories. In a probabilistic assessment of dose, whether from a planned facility or an existing situation, the Commission recommends that the representative person should be defined such that the probability is less than about 5% that a person drawn at random from the population will receive a greater dose. If such an assessment indicates that a few tens of people or more could receive doses above the relevant constraint, the characteristics of these people need to be explored. If, following further analysis, it is shown that doses to a few tens of people are indeed likely to exceed the relevant dose constraint, actions to modify the exposure should be considered. The Commission recognises the role that stakeholders can play in identifying characteristics of the representative person. Involvement of stakeholders can significantly improve the quality, understanding, and acceptability of the characteristics of the representative person and the resulting estimated dose.

  9. Effect of the addition of IGF-I and vitamin E to stored boar semen.

    PubMed

    Mendez, M F B; Zangeronimo, M G; Rocha, L G P; Faria, B G; Pereira, B A; Fernandes, C D; Chaves, B R; Murgas, L D S; Sousa, R V

    2013-05-01

    The objective of this study was to evaluate the addition of IGF-I to pig insemination doses stored at 15°C, in conjunction with the addition of different amounts of vitamin E (α-tocopherol). Semen samples (n = 12) from four boars were treated by the addition of different concentrations of vitamin E, ranging up to 400 μg/ml. Immediately after processing and after the doses had been stored at 15°C for 24 or 72 h, samples were warmed at 37°C and 30 ng/ml of IGF-I was added. The assessments were made after 10 and 120 min of IGF-I addition. There was a minor effect of the vitamin E added before cooling and IGF-I added after storage on sperm quality. The addition of 400 μg/ml of vitamin E to diluted semen reduced (P < 0.01) the malondialdehyde (MDA) production in boar semen stored at 15°C for 72 h, regardless of the addition of IGF-I as additive during a 120 min incubation period at 37°C. In these conditions, IGF-I also reduced (P < 0.05) the MDA production in semen samples without addition of vitamin E. IGF-I in the presence of vitamin E reduced (P = 0.03) the glucose intake in freshly diluted boar semen samples before cooling. It was concluded that the addition of 400 μg/ml of vitamin E reduces the MDA production in boar semen stored at 15°C for 72 h, regardless of the presence of IGF-I additive. The addition of IGF-I in doses stored for 72 h with vitamin E ensures higher sperm motility after 120 min of incubation at 37°C.

  10. CIE, Vitamin D and DNA Damage: A Synergetic Study in Thessaloniki, Greece

    NASA Astrophysics Data System (ADS)

    Zempila, Melina Maria; Taylor, Michael; Fountoulakis, Ilias; Koukouli, Maria Elissavet; Bais, Alkiviadis; Arola, Antii; van Geffen, Jos; van Weele, Michiel; van der A, Ronald; Kouremeti, Natalia; Kazadzis, Stelios; Meleti, Chariklia; Balis, Dimitrios

    2016-08-01

    The present study aims to validate different approaches for the estimation of three photobiological effective doses: the erythemal UV, the vitamin D and that for DNA damage, using high temporal resolution surface- based measurements of solar UV from 2005-2015. Data from a UV spectrophotometer, a multi-filter radiometer, and a UV radiation pyranometer that are located in Thessaloniki, Greece are used together with empirical relations, algorithms and models in order to calculate the desired quantities. In addition to the surface-based dose retrievals, OMI/Aura and the combined SCIAMACHY/Envisat and GOME/MetopA satellite products are also used in order to assess the accuracy of each method for deriving the photobiological doses.

  11. Only minor additional metabolic health benefits of high as opposed to moderate dose physical exercise in young, moderately overweight men.

    PubMed

    Reichkendler, M H; Rosenkilde, M; Auerbach, P L; Agerschou, J; Nielsen, M B; Kjaer, A; Hoejgaard, L; Sjödin, A; Ploug, T; Stallknecht, B

    2014-05-01

    The dose-response effects of exercise training on insulin sensitivity, metabolic risk, and quality of life were examined. Sixty-one healthy, sedentary (VO₂max: 35 ± 5 ml/kg/min), moderately overweight (BMI: 27.9 ± 1.8), young (age: 29 ± 6 years) men were randomized to sedentary living (sedentary control group; n = 18), moderate (moderate dose training group [MOD]: 300 kcal/day, n = 21), or high (high dose training group [HIGH]: 600 kcal/day, n = 22) dose physical exercise for 11 weeks. The return rate for post-intervention testing was 82-94% across groups. Weekly exercise amounted to 2,004 ± 24 and 3,774 ± 68 kcal, respectively, in MOD and HIGH. Cardiorespiratory fitness increased (P < 0.001) 18 ± 3% in MOD and 17 ± 3% in HIGH, and fat percentage decreased (P < 0.001) similarly in both exercise groups (MOD: 32 ± 1 to 29 ± 1%; HIGH: 30 ± 1 to 27 ± 1%). Peripheral insulin sensitivity increased (P < 0.01) (MOD: 28 ± 7%; HIGH: 36 ± 8%) and the homeostasis model assessment of insulin resistance decreased (P < 0.05) (MOD: -17 ± 7%; HIGH: -18 ± 10%). The number of subjects meeting the criteria of the metabolic syndrome decreased by 78% in MOD (P < 0.01) and by 80% in HIGH (P < 0.05). General health assessed by questionnaire increased similarly in MOD (P < 0.05) and HIGH (P < 0.01). Only minor additional health benefits were found when exercising ∼3,800 as opposed to ∼2,000 kcal/week in young moderately overweight men. This finding may have important public health implications. Copyright © 2012 The Obesity Society.

  12. Neutron organ dose and the influence of adipose tissue

    NASA Astrophysics Data System (ADS)

    Simpkins, Robert Wayne

    Neutron fluence to dose conversion coefficients have been assessed considering the influences of human adipose tissue. Monte Carlo code MCNP4C was used to simulate broad parallel beam monoenergetic neutrons ranging in energy from thermal to 10 MeV. Simulated Irradiations were conducted for standard irradiation geometries. The targets were on gender specific mathematical anthropomorphic phantoms modified to approximate human adipose tissue distributions. Dosimetric analysis compared adipose tissue influence against reference anthropomorphic phantom characteristics. Adipose Male and Post-Menopausal Female Phantoms were derived introducing interstitial adipose tissue to account for 22 and 27 kg additional body mass, respectively, each demonstrating a Body Mass Index (BMI) of 30. An Adipose Female Phantom was derived introducing specific subcutaneous adipose tissue accounting for 15 kg of additional body mass demonstrating a BMI of 26. Neutron dose was shielded in the superficial tissues; giving rise to secondary photons which dominated the effective dose for Incident energies less than 100 keV. Adipose tissue impact on the effective dose was a 25% reduction at the anterior-posterior incidence ranging to a 10% increase at the lateral incidences. Organ dose impacts were more distinctive; symmetrically situated organs demonstrated a 15% reduction at the anterior-posterior Incidence ranging to a 2% increase at the lateral incidences. Abdominal or asymmetrically situated organs demonstrated a 50% reduction at the anterior-posterior incidence ranging to a 25% increase at the lateral incidences.

  13. Food irradiation dosimetry by opti-chromic technique

    NASA Astrophysics Data System (ADS)

    Zhan-Jun, Liu; Radak, B. B.; McLaughlin, W. L.

    The measurement of gamma-radiation quantities, e.g., absorbed dose in materials such as water, plastics, foodstuffs, is a convenient means of quality assurance in radiation processing. A new dosimetry system, called the "Opti-Chromic" dosimeter, is commercially available in large batches for use as a routine measurement system in the absorbed dose range 10 to 2x10 4 Gy. This dose range covers most food irradiation applications. A statistical evaluation was made of the reproducibility of this dosimeter for measuring doses appropriate for the disinfestation and shelf-life extension of many foods, namely 10 to 2x10 3 Gy. In addition, the small dosimeters were used to map absorbed dose distributions in boxes of foods having four different bulk densities (grapefruit, lemons, peanuts, and wheat bran). It is demonstrated that the dosimeters are rugged and stable enough to be used over a wide temperature and humidity range, and, in fact, can be placed in such environments as the inside of citrus fruits without adverse effects on their ability to give satisfactory dose assessment.

  14. Relationship between Eustachian tube dysfunction and otitis media with effusion in radiotherapy patients.

    PubMed

    Akazawa, K; Doi, H; Ohta, S; Terada, T; Fujiwara, M; Uwa, N; Tanooka, M; Sakagami, M

    2018-02-01

    This study evaluated the relationship between radiation and Eustachian tube dysfunction, and examined the radiation dose required to induce otitis media with effusion. The function of 36 Eustachian tubes in 18 patients with head and neck cancer were examined sonotubometrically before, during, and 1, 2 and 3 months after, intensity-modulated radiotherapy. Patients with an increase of 5 dB or less in sound pressure level (dB) during swallowing were categorised as being in the dysfunction group. Additionally, radiation dose distributions were assessed in all Eustachian tubes using three dose-volume histogram parameters. Twenty-two of 25 normally functioning Eustachian tubes before radiotherapy (88.0 per cent) shifted to the dysfunction group after therapy. All ears that developed otitis media with effusion belonged to the dysfunction group. The radiation dose threshold evaluation revealed that ears with otitis media with effusion received significantly higher doses to the Eustachian tubes. The results indicate a relationship between radiation dose and Eustachian tube dysfunction and otitis media with effusion.

  15. Cytogenetic damage in the blood lymphocytes of astronauts: effects of repeat long-duration space missions.

    PubMed

    George, K; Rhone, J; Beitman, A; Cucinotta, F A

    2013-08-30

    Human missions onboard the International Space Station (ISS) are increasing in duration and several astronauts have now participated in second ISS increments. The radiation environment in space is very different from terrestrial radiation exposure and it is still unclear if space flight effects and radiation from repeat missions are simply additive, which potentially confounds the assessment of the cumulative risk of radiation exposure. It has been shown that single space missions of a few months or more on the ISS can induce measureable increases in the yield of chromosome damage in the blood lymphocytes of astronauts, and it appears that cytogenetic biodosimetry can be used reliably to estimate equivalent dose and radiation risk. We have now obtained direct in vivo measurements of chromosome damage in blood lymphocytes of five astronauts before and after their first and second long duration space flights. Chromosome damage was assessed by fluorescence in situ hybridization technique using three different chromosome painting probes. All astronauts showed an increase in total exchanges and translocations after both the first and second flight. Biological dose measured using either individual assessment or a population assessment supports an additive risk model. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26.

    PubMed

    Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Donald; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A

    2017-10-01

    This review summarizes the conclusions and recommendations of the new National Council on Radiation Protection and Measurements (NCRP) Commentary No. 26 guidance on radiation dose limits for the lens of the eye. The NCRP addressed radiation protection principles in respect to the lens of the eye, discussed the current understanding of eye biology and lens effects, reviewed and evaluated epidemiology, and assessed exposed populations with the potential for significant radiation exposures to the lens while suggesting monitoring and protection practices. Radiation-induced damage to the lens of the eye can include the loss of clarity resulting in opacification or clouding several years after exposure. The impact is highly dependent on the type of radiation, how the exposure of the lens was delivered, the genetic susceptibilities of the individual exposed, and the location of the opacity relative to the visual axis of the individual. The preponderance of epidemiological evidence suggests that lens damage could occur at lower doses than previously considered and the NCRP has determined that it is prudent to reduce the recommended annual lens of the eye occupational dose limit from an equivalent dose of 150 mSv to an absorbed dose of 50 mGy. Significant additional research is still needed in the following areas: comprehensive evaluation of the overall effects of ionizing radiation on the eye, dosimetry methodology and dose-sparing optimization techniques, additional high quality epidemiology studies, and a basic understanding of the mechanisms of cataract development.

  17. A Randomized Double-Blind, Placebo Controlled, Four-Arm Parallel Study Investigating the Effect of a Broad-Spectrum Wellness Beverage on Mood State in Healthy, Moderately Stressed Adults.

    PubMed

    Evans, Malkanthi; Antony, Joseph; Guthrie, Najla; Landes, Bernie; Aruoma, Okezie I

    2018-01-01

    The objective of this study was to investigate the effect of a broad-spectrum wellness beverage (Zeal Wellness [ZW]) on standardized measures of mood states, including overall feelings of vitality, in healthy, moderately stressed adults. A randomized, double-blind, placebo-controlled clinical trial was conducted among 99 eligible participants prescreened for moderate stress. Participants were randomized to one of four groups and received ZW once daily (1-dose-ZW; 14 g), ZW twice daily (2-dose-ZW; 28 g), placebo once daily (1-dose-placebo), or placebo twice daily (2-dose-placebo) for 4 weeks. A stress/vitality questionnaire assessed stress and the Profile of Moods (POMS) Questionnaire assessed vigor via mental/physical energy and global mood state. Safety was assessed by clinical chemistry, liver, kidney function, and anthropometric measures and adverse event reporting. Participants receiving 2-dose-ZW reported a 6.6% decrease in scores on POMS-Total Mood Disturbance (TMD; p < 0.05) and a 6.8% decrease in the anger-hostility mood state (p < 0.022) compared to the combined placebo group at day 29. The 2-dose-ZW provided a 12.8% greater improvement in POMS-TMD scores when compared to participants receiving 1-dose-ZW after 28 days of supplementation (p = 0.014). Within groups, there was a 22.4% and a 9.6% decrease in POMS-TMD scores in participants with 2-dose-ZW and 1-dose-ZW, respectively. In addition, participants receiving 2-dose-ZW showed significant improvements (p = 0.001) in the POMS t-score iceberg profile, which represented a shift to a more healthy profile. These data show that daily supplementation with 2-dose-ZW significantly decreased POMS-TMD scores and anger-hostility mood state and shifted the POMS iceberg profile to a healthy profile compared to the combined placebo, reflecting the functional benefit of rice-bran-fruit-vegetable extracts based beverage on health.

  18. Is the use of the cervical vertebrae maturation method justified to determine skeletal age? A comparison of radiation dose of two strategies for skeletal age estimation.

    PubMed

    Patcas, Raphael; Signorelli, Luca; Peltomäki, Timo; Schätzle, Marc

    2013-10-01

    The aim of this study was to assess effective doses of a lateral cephalogram radiograph with and without thyroid shield and compare the differences with the radiation dose of a hand-wrist radiograph. Thermoluminescent dosimeters were placed at 19 different sites in the head and neck of a tissue-equivalent human skull (RANDO phantom). Analogue lateral cephalograms with and without thyroid shield (67 kV, 250 mA, 10 mAs) and hand-wrist radiographs (40 kV, 250 mA, 10 mAs) were obtained. The effective doses were calculated using the 2007 International Commission on Radiological Protection recommendations. The effective dose for conventional lateral cephalogram without a thyroid shield was 5.03 microsieverts (µSv). By applying a thyroid shield to the RANDO phantom, a remarkable dose reduction of 1.73 µSv could be achieved. The effective dose of a conventional hand-wrist radiograph was calculated to be 0.16 µSv. Adding the effective dose of the hand-wrist radiograph to the effective dose of the lateral cephalogram with thyroid shield resulted in a cumulative effective dose of 3.46 µSv. Without thyroid shield, the effective dose of a lateral cephalogram was approximately 1.5-fold increased than the cumulative effective dose of a hand-wrist radiograph and a lateral cephalogram with thyroid shield. Thyroid is an organ that is very sensitive to radiation exposure. Its shielding will significantly reduce the effective dose. An additional hand-wrist radiograph, involving no vulnerable tissues, however, causes very little radiation risk. In accordance with the ALARA (As Low As Reasonably Achievable) principle, if an evaluation of skeletal age is indicated, an additional hand-wrist radiograph seems much more justifiable than removing the thyroid shield.

  19. Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel

    NASA Astrophysics Data System (ADS)

    Kairn, T.; Kakakhel, M. B.; Johnston, H.; Jirasek, A.; Trapp, J. V.

    2015-01-01

    The signal-to-noise ratio achievable in x-ray computed tomography (CT) images of polymer gels can be increased by averaging over multiple scans of each sample. However, repeated scanning delivers a small additional dose to the gel which may compromise the accuracy of the dose measurement. In this study, a NIPAM-based polymer gel was irradiated and then CT scanned 25 times, with the resulting data used to derive an averaged image and a "zero-scan" image of the gel. Comparison between these two results and the first scan of the gel showed that the averaged and zero-scan images provided better contrast, higher contrast-to- noise and higher signal-to-noise than the initial scan. The pixel values (Hounsfield units, HU) in the averaged image were not noticeably elevated, compared to the zero-scan result and the gradients used in the linear extrapolation of the zero-scan images were small and symmetrically distributed around zero. These results indicate that the averaged image was not artificially lightened by the small, additional dose delivered during CT scanning. This work demonstrates the broader usefulness of the zero-scan method as a means to verify the dosimetric accuracy of gel images derived from averaged x-ray CT data.

  20. Suppression of ciprofloxacin-induced resistant Pseudomonas aeruginosa in a dynamic kill curve system.

    PubMed

    Wu, Benjamin M; Sabarinath, Sreedharan N; Rand, Kenneth; Johnson, Judith; Derendorf, Hartmut

    2011-06-01

    Current dosing approaches for treating microbial infections ignore resistant subpopulations. A clinical isolate of Pseudomonas aeruginosa was cultured in a dynamic in vitro kill curve system designed to simulate the half-lives of drugs in order to evaluate the drug-microbial response relationship. The first dose of ciprofloxacin (CIP) uses a concentration equivalent to the unbound fraction of a 200mg clinical dose. A second dose of 200mg or 600 mg CIP, or ceftriaxone (CFX) or gentamicin (GEN) was administered at 12h. Dynamics of the minimum inhibitory concentration (MIC) were assessed using Etest strips before and throughout the CIP treatment period. In addition, the microbroth dilution method was used to evaluate drug susceptibility across a wide range of antibiotics using samples from before and after CIP exposure. A significant loss of CIP effects was observed at the second dose. Cross-resistance to many antibiotics (cefoxitin, cefuroxime, cefotetan, ampicillin and ertapenem) was observed. GEN, but not CFX or high-dose CIP, was sufficient to suppress the developed resistant subpopulation following the initial CIP exposure. The CIP MIC increased substantially from 0.13 μg/mL pre dose to 4 μg/mL at 12h after a CIP dose. In addition, aztreonam induced a similar resistance pattern as CIP, indicating that induction of resistance was not limited to fluoroquinolones. In conclusion, the in vitro dynamic kill curve system revealed that aminoglycosides, more than other classes of antibiotics, were effective against the CIP-induced resistant subpopulations. Copyright © 2011 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  1. Synergy and other ineffective mixture risk definitions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertzberg, R.; MacDonell, M.; Environmental Assessment

    2002-04-08

    A substantial effort has been spent over the past few decades to label toxicologic interaction outcomes as synergistic, antagonistic, or additive. Although useful in influencing the emotions of the public and the press, these labels have contributed fairly little to our understanding of joint toxic action. Part of the difficulty is that their underlying toxicological concepts are only defined for two chemical mixtures, while most environmental and occupational exposures are to mixtures of many more chemicals. Furthermore, the mathematical characterizations of synergism and antagonism are inextricably linked to the prevailing definition of 'no interaction,' instead of some intrinsic toxicological property.more » For example, the US EPA has selected dose addition as the no-interaction definition for mixture risk assessment, so that synergism would represent toxic effects that exceed those predicted from dose addition. For now, labels such as synergism are useful to regulatory agencies, both for qualitative indications of public health risk as well as numerical decision tools for mixture risk characterization. Efforts to quantify interaction designations for use in risk assessment formulas, however, are highly simplified and carry large uncertainties. Several research directions, such as pharmacokinetic measurements and models, and toxicogenomics, should promote significant improvements by providing multi-component data that will allow biologically based mathematical models of joint toxicity to replace these pairwise interaction labels in mixture risk assessment procedures.« less

  2. The sedative and analgesic effects of detomidine-butorphanol and detomidine alone in donkeys.

    PubMed

    Joubert, K E; Briggs, P; Gerber, D; Gottschalk, R G

    1999-09-01

    Butorphanol and detomidine constitute an effective combination for sedation and analgesia in horses. This trial was undertaken to assess the effectiveness of this combination in donkeys. The detomidine and butorphanol were given intravenously one after the other. A dose of 10 microg/kg of detomidine and 25 microg/kg of butorphanol was used. Sedation is easily extended by additional doses of butorphanol. The average dose of detomidine was 11.24 microg/kg and that of butorphanol was 28.0 microg/kg. Four donkeys in the detomidine group required additional sedation and analgesia. Detomidine alone did not totally eliminate coronary band pain. Heart rates dropped significantly in the first minute after the injection of the combination. One donkey developed an atrioventricular block, while another developed a sino-atrial block. Four donkeys developed a Cheyne-Stokes respiratory pattern. The combination of detomidine and butorphanol is an effective combination for sedation and analgesia of donkeys for standing procedures.

  3. The benefit of individualized low-dose hCG support for high responders in GnRHa-triggered IVF/ICSI cycles.

    PubMed

    Huang, Chen-Yu; Shieh, Miawh-Lirng; Li, Hsin-Yang

    2016-07-01

    To assess the pregnancy outcome and ovarian hyperstimulation syndrome (OHSS) incidence in high responders receiving gonadotropin-releasing hormone agonist (GnRHa) trigger plus individualized support of low-dose human chorionic gonadotropin (hCG). Such support includes 500-1000 IU hCG given at trigger and, if serum estradiol (E2) dropped to below 800 pg/mL before the 6(th) day after oocyte retrieval, an additional rescue dose of 300 IU hCG. This was a retrospective study of potential high responders aged from 28 years to 40 years at a tertiary fertility center in Taiwan. By means of chart review, we assessed the pregnancy outcome and OHSS incidence in high responders receiving GnRHa trigger plus individualized low-dose hCG support. The main outcomes were measured by ongoing pregnancy rate and OHSS incidence (SPSS), in which statistical significance was determined by Chi-square test. Moderate to severe OHSS did not develop in any patient receiving GnRHa trigger plus individualized low-dose hCG support. In fact, a satisfactory ongoing pregnancy rate (46.9%) was noted in patients receiving GnRHa trigger plus individualized low-dose hCG support. Our study suggested that GnRHa trigger combined with individualized low-dose hCG support appears to be a safe approach with a satisfactory pregnancy outcome. Copyright © 2016. Published by Elsevier Taiwan LLC.

  4. RADIATION DOSE ASSESSMENT FOR THE BIOTA OF TERRESTRIAL ECOSYSTEMS IN THE SHORELINE ZONE OF THE CHERNOBYL NUCLEAR POWER PLANT COOLING POND

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farfan, E.; Jannik, T.

    2011-10-01

    Radiation exposure of the biota in the shoreline area of the Chernobyl Nuclear Power Plant Cooling Pond was assessed to evaluate radiological consequences from the decommissioning of the Cooling Pond. The article addresses studies of radioactive contamination of the terrestrial faunal complex and radionuclide concentration ratios in bodies of small birds, small mammals, amphibians, and reptiles living in the area. The data were used to calculate doses to biota using the ERICA Tool software. Doses from {sup 90}Sr and {sup 137}Cs were calculated using the default parameters of the ERICA Tool and were shown to be consistent with biota dosesmore » calculated from the field data. However, the ERICA dose calculations for plutonium isotopes were much higher (2-5 times for small mammals and 10-14 times for birds) than the doses calculated using the experimental data. Currently, the total doses for the terrestrial biota do not exceed maximum recommended levels. However, if the Cooling Pond is allowed to drawdown naturally and the contaminants of the bottom sediments are exposed and enter the biological cycle, the calculated doses to biota may exceed the maximum recommended values. The study is important in establishing the current exposure conditions such that a baseline exists from which changes can be documented following the lowering of the reservoir water. Additionally, the study provided useful radioecological data on biota concentration ratios for some species that are poorly represented in the literature.« less

  5. Cytochrome P450 2C9 gene polymorphism and warfarin maintenance dosage in pediatric patients: A systematic review and meta-analysis.

    PubMed

    Zhang, Jinhua; Tian, Lihong; Huang, Jinlong; Huang, Sihan; Chai, Tingting; Shen, Jianzhen

    2017-02-01

    To assess the effect of Cytochrome P450 2C9 (CYP2C9) gene polymorphism on pediatric warfarin maintenance dosage requirement. A previously developed search strategy was conducted in PubMed, EMBASE, and the Cochrane Library. Eligible studies published prior to January 27, 2016, were identified and compared against strict inclusion/exclusion criteria. Required data were extracted, and researchers were consulted for additional data if needed. Review Manager version 5.2.3 software was used to analyze the relationship between CYP2C9 polymorphisms and warfarin maintenance doses in pediatric patients. Eight articles with a combined total of 507 pediatric patients were included in the meta-analysis. Maintenance warfarin doses in patients with CYP2C9 *1/*2 genotype, CYP2C9 *1/*3 genotype, and CYP2C9 variant carriers which contain at least one variant allele (*2 or *3) were from 15% to 41% lower than doses in patients with the wild-type allele (CYP2C9 *1/*1): All differences were significant with P-values <.05. The Fontan procedure as a medical indication for anticoagulation was also associated with a lower warfarin maintenance dose; however, target INR range was not. We found that CYP2C9 gene polymorphism (referring to the presence of *1/*2, *1/*3, and variant genotypes in the population in addition to the wild type) was significantly associated with decreased warfarin maintenance dose requirements. Additionally, a specific indication for warfarin, the Fontan procedure, was associated with a lower daily warfarin dose. However, the results of our study require confirmation from more research with larger numbers of pediatric patients. © 2016 John Wiley & Sons Ltd.

  6. Effectiveness and gastrointestinal tolerability during conversion and titration with once-daily OROS® hydromorphone extended release in opioid-tolerant patients with chronic low back pain

    PubMed Central

    Hale, Martin E; Nalamachu, Srinivas R; Khan, Arif; Kutch, Michael

    2013-01-01

    Purpose To describe the efficacy and safety of hydromorphone extended-release tablets (OROS hydromorphone ER) during dose conversion and titration. Patients and methods A total of 459 opioid-tolerant adults with chronic moderate to severe low back pain participated in an open-label, 2- to 4-week conversion/titration phase of a double-blind, placebo-controlled, randomized withdrawal trial, conducted at 70 centers in the United States. Patients were converted to once-daily OROS hydromorphone ER at 75% of the equianalgesic dose of their prior total daily opioid dose (5:1 conversion ratio), and titrated as frequently as every 3 days to a maximum dose of 64 mg/day. The primary outcome measure was change in pain intensity numeric rating scale; additional assessments included the Patient Global Assessment and the Roland–Morris Disability Questionnaire scores. Safety assessments were performed at each visit and consisted of recording and monitoring all adverse events (AEs) and serious AEs. Results Mean (standard deviation) final daily dose of OROS hydromorphone ER was 37.5 (17.8) mg. Mean (standard error of the mean [SEM]) numeric rating scale scores decreased from 6.6 (0.1) at screening to 4.3 (0.1) at the final titration visit (mean [SEM] change, −2.3 [0.1], representing a 34.8% reduction). Mean (SEM) change in Patient Global Assessment was −0.6 (0.1), and mean change (SEM) in the Roland–Morris Disability Questionnaire was −2.8 (0.3). Patients achieving a stable dose showed greater improvement than patients who discontinued during titration for each of these measures (P < 0.001). Almost 80% of patients achieving a stable dose (213/268) had a ≥30% reduction in pain. Commonly reported AEs were constipation (15.4%), nausea (11.9%), somnolence (8.7%), headache (7.8%), and vomiting (6.5%); 13.0% discontinued from the study due to AEs. Conclusion The majority of opioid-tolerant patients with chronic low back pain were successfully converted to effective doses of OROS hydromorphone ER within 2 to 4 weeks. PMID:23658495

  7. Combining Toxicological and Chemical Characterization of Complex Mixtures to Understand the Impact of the Unknown Fraction

    EPA Science Inventory

    Toxicological assessment of adverse health outcomes associated with exposure to complex mixtures provides an integrated response of the organism (or in vitro test system) that accounts for additivity among the components (both dose and response) as well as any greater than or les...

  8. 75 FR 60321 - Spinosad; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-30

    ... addition to filing an objection or hearing request with the Hearing Clerk as described in 40 CFR part 178... reference values for risk assessment. PODs are developed based on a careful analysis of the doses in each..., Brassica leafy vegetables, citrus, fruiting vegetables, herbs, banana, grape, several cereal grains, and...

  9. Spot scanning proton therapy plan assessment: design and development of a dose verification application for use in routine clinical practice

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Walsh, Timothy J.; Beltran, Chris J.; Stoker, Joshua B.; Mundy, Daniel W.; Parry, Mark D.; Bues, Martin; Fatyga, Mirek

    2016-04-01

    The use of radiation therapy for the treatment of cancer has been carried out clinically since the late 1800's. Early on however, it was discovered that a radiation dose sufficient to destroy cancer cells can also cause severe injury to surrounding healthy tissue. Radiation oncologists continually strive to find the perfect balance between a dose high enough to destroy the cancer and one that avoids damage to healthy organs. Spot scanning or "pencil beam" proton radiotherapy offers another option to improve on this. Unlike traditional photon therapy, proton beams stop in the target tissue, thus better sparing all organs beyond the targeted tumor. In addition, the beams are far narrower and thus can be more precisely "painted" onto the tumor, avoiding exposure to surrounding healthy tissue. To safely treat patients with proton beam radiotherapy, dose verification should be carried out for each plan prior to treatment. Proton dose verification systems are not currently commercially available so the Department of Radiation Oncology at the Mayo Clinic developed its own, called DOSeCHECK, which offers two distinct dose simulation methods: GPU-based Monte Carlo and CPU-based analytical. The three major components of the system include the web-based user interface, the Linux-based dose verification simulation engines, and the supporting services and components. The architecture integrates multiple applications, libraries, platforms, programming languages, and communication protocols and was successfully deployed in time for Mayo Clinic's first proton beam therapy patient. Having a simple, efficient application for dose verification greatly reduces staff workload and provides additional quality assurance, ultimately improving patient safety.

  10. Bayesian Dose-Response Modeling in Sparse Data

    NASA Astrophysics Data System (ADS)

    Kim, Steven B.

    This book discusses Bayesian dose-response modeling in small samples applied to two different settings. The first setting is early phase clinical trials, and the second setting is toxicology studies in cancer risk assessment. In early phase clinical trials, experimental units are humans who are actual patients. Prior to a clinical trial, opinions from multiple subject area experts are generally more informative than the opinion of a single expert, but we may face a dilemma when they have disagreeing prior opinions. In this regard, we consider compromising the disagreement and compare two different approaches for making a decision. In addition to combining multiple opinions, we also address balancing two levels of ethics in early phase clinical trials. The first level is individual-level ethics which reflects the perspective of trial participants. The second level is population-level ethics which reflects the perspective of future patients. We extensively compare two existing statistical methods which focus on each perspective and propose a new method which balances the two conflicting perspectives. In toxicology studies, experimental units are living animals. Here we focus on a potential non-monotonic dose-response relationship which is known as hormesis. Briefly, hormesis is a phenomenon which can be characterized by a beneficial effect at low doses and a harmful effect at high doses. In cancer risk assessments, the estimation of a parameter, which is known as a benchmark dose, can be highly sensitive to a class of assumptions, monotonicity or hormesis. In this regard, we propose a robust approach which considers both monotonicity and hormesis as a possibility. In addition, We discuss statistical hypothesis testing for hormesis and consider various experimental designs for detecting hormesis based on Bayesian decision theory. Past experiments have not been optimally designed for testing for hormesis, and some Bayesian optimal designs may not be optimal under a wrong parametric assumption. In this regard, we consider a robust experimental design which does not require any parametric assumption.

  11. New insights into mycotoxin mixtures: The toxicity of low doses of Type B trichothecenes on intestinal epithelial cells is synergistic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alassane-Kpembi, Imourana; Université de Toulouse, ENVT, INP, UMR 1331 Toxalim, F-31076 Toulouse; Institut des Sciences Biomédicales Appliquées, Cotonou, Bénin

    Deoxynivalenol (DON) is the most prevalent trichothecene mycotoxin in crops in Europe and North America. DON is often present with other type B trichothecenes such as 3-acetyldeoxynivalenol (3-ADON), 15-acetyldeoxynivalenol (15-ADON), nivalenol (NIV) and fusarenon-X (FX). Although the cytotoxicity of individual mycotoxins has been widely studied, data on the toxicity of mycotoxin mixtures are limited. The aim of this study was to assess interactions caused by co-exposure to Type B trichothecenes on intestinal epithelial cells. Proliferating Caco-2 cells were exposed to increasing doses of Type B trichothecenes, alone or in binary or ternary mixtures. The MTT test and neutral red uptake,more » respectively linked to mitochondrial and lysosomal functions, were used to measure intestinal epithelial cytotoxicity. The five tested mycotoxins had a dose-dependent effect on proliferating enterocytes and could be classified in increasing order of toxicity: 3-ADON < 15-ADON ≈ DON < NIV ≪ FX. Binary or ternary mixtures also showed a dose-dependent effect. At low concentrations (cytotoxic effect between 10 and 30–40%), mycotoxin combinations were synergistic; however DON–NIV–FX mixture showed antagonism. At higher concentrations (cytotoxic effect around 50%), the combinations had an additive or nearly additive effect. These results indicate that the simultaneous presence of low doses of mycotoxins in food commodities and diet may be more toxic than predicted from the mycotoxins alone. Considering the frequent co-occurrence of trichothecenes in the diet and the concentrations of toxins to which consumers are exposed, this synergy should be taken into account. - Highlights: • We assessed the individual and combined cytotoxicity of five trichothecenes. • The tested concentrations correspond to the French consumer exposure levels. • The type of interaction in combined cytotoxicity varied with the effect level. • Low doses of Type B trichothecenes induced synergistic cytotoxicity. • Ternary combination DON–NIV–FX showed antagonism.« less

  12. Genistein aglycone effect on bone loss is not enhanced by supplemental calcium and vitamin D3: a dose ranging experimental study.

    PubMed

    Bitto, A; Marini, H; Burnett, B P; Polito, F; Levy, R M; Irrera, N; Minutoli, L; Adamo, E B; Squadrito, F; Altavilla, D

    2011-07-15

    Genistein aglycone (GEN) has a favorable effect on bone loss. We investigated the effects of GEN alone or in combination with supplemental calcium and vitamin D(3) in an animal model of bone loss to evaluate if there was additional benefit. Ovariectomized (OVX) and SHAM-OVX rats were used. OVX were divided into 12 groups and randomized to receive: GEN at 27, 54, 200, 500 or 1000 mg (human equivalent dose (HED)/day/ip injection alone or with calcium carbonate (Ca) (360 mg/kg/day/gavages) and vitamin D(3) (D(3)) (50 IU/kg/day/gavages) or Ca/D(3) without GEN or untreated for 6 weeks. SHAM-OVX were randomized into 7 groups and treated with: Ca and D(3) alone or in combination with GEN (same doses as OVX), or left untreated. Bone mineral density (BMD), bone-alkaline phosphatase (b-ALP), collagen C-telopeptides (CTX), osteoprotegerin (OPG) and soluble receptor activator of NFκB ligand (sRANKL) were assessed. Femurs were excised and tested for breaking strength and histology. Uterine weight was analyzed to assess GEN's estrogenic effects on the SHAM-OVX. The most effective dose of GEN, independent of Ca/D(3) supplementation, was 54 mg/day. Higher doses yielded no further improvement in bone biomarkers, histology or strength. Only 1000 mg/day HED of genistein produced statistically significant changes in uterine weight of the SHAM-OVX. This study suggests that 54 mg/day of GEN is the threshold dose for efficacy. In addition, supplemental calcium and vitamin D(3), beyond normal dietary intake do not enhance the effects of genistein on improving measures of bone loss. This observation has implications regarding the use of calcium and vitamin D(3) supplementation. Copyright © 2011 Elsevier GmbH. All rights reserved.

  13. Comparison of exposure assessment methods in a lung cancer case-control study: performance of a lifelong task-based questionnaire for asbestos and PAHs.

    PubMed

    Bourgkard, Eve; Wild, Pascal; Gonzalez, Maria; Févotte, Joëlle; Penven, Emmanuelle; Paris, Christophe

    2013-12-01

    To describe the performance of a lifelong task-based questionnaire (TBQ) in estimating exposures compared with other approaches in the context of a case-control study. A sample of 93 subjects was randomly selected from a lung cancer case-control study corresponding to 497 jobs. For each job, exposure assessments for asbestos and polycyclic aromatic hydrocarbons (PAHs) were obtained by expertise (TBQ expertise) and by algorithm using the TBQ (TBQ algorithm) as well as by expert appraisals based on all available occupational data (REFERENCE expertise) considered to be the gold standard. Additionally, a Job Exposure Matrix (JEM)-based evaluation for asbestos was also obtained. On the 497 jobs, the various evaluations were contrasted using Cohen's κ coefficient of agreement. Additionally, on the total case-control population, the asbestos dose-response relationship based on the TBQ algorithm was compared with the JEM-based assessment. Regarding asbestos, the TBQ-exposure estimates agreed well with the REFERENCE estimate (TBQ expertise: level-weighted κ (lwk)=0.68; TBQ algorithm: lwk=0.61) but less so with the JEM estimate (TBQ expertise: lwk=0.31; TBQ algorithm: lwk=0.26). Regarding PAHs, the agreements between REFERENCE expertise and TBQ were less good (TBQ expertise: lwk=0.43; TBQ algorithm: lwk=0.36). In the case-control study analysis, the dose-response relationship between lung cancer and cumulative asbestos based on the JEM is less steep than with the TBQ-algorithm exposure assessment and statistically non-significant. Asbestos-exposure estimates based on the TBQ were consistent with the REFERENCE expertise and yielded a steeper dose-response relationship than the JEM. For PAHs, results were less clear.

  14. Low-dose CT in clinical diagnostics.

    PubMed

    Fuentes-Orrego, Jorge M; Sahani, Dushyant V

    2013-09-01

    Computed tomography (CT) has become key for patient management due to its outstanding capabilities for detecting disease processes and assessing treatment response, which has led to expansion in CT imaging for diagnostic and image-guided therapeutic interventions. Despite these benefits, the growing use of CT has raised concerns as radiation risks associated with radiation exposure. The purpose of this article is to familiarize the reader with fundamental concepts of dose metrics for assessing radiation exposure and weighting radiation-associated risks. The article also discusses general approaches for reducing radiation dose while preserving diagnostic quality. The authors provide additional insight for undertaking protocol optimization, customizing scanning techniques based on the patients' clinical scenario and demographics. Supplemental strategies are postulated using more advanced post-processing techniques for achieving further dose improvements. The technologic offerings of CT are integral to modern medicine and its role will continue to evolve. Although, the estimated risks from low levels of radiation of a single CT exam are uncertain, it is prudent to minimize the dose from CT by applying common sense solutions and using other simple strategies as well as exploiting technologic innovations. These efforts will enable us to take advantage of all the clinical benefits of CT while minimizing the likelihood of harm to patients.

  15. Assessing pediatrics residents' mathematical skills for prescribing medication: a need for improved training.

    PubMed

    Glover, Mark L; Sussmane, Jeffrey B

    2002-10-01

    To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.

  16. Estimating the impact of grouping misclassification on risk ...

    EPA Pesticide Factsheets

    Environmental health risk assessments of chemical mixtures that rely on component approaches often begin by grouping the chemicals of concern according to toxicological similarity. Approaches that assume dose addition typically are used for groups of similarly-acting chemicals and those that assume response addition are used for groups of independently acting chemicals. Grouping criteria for similarity can include a common adverse outcome pathway (AOP) and similarly shaped dose-response curves, with the latter used in the relative potency factor (RPF) method for estimating mixture response. Independence of toxic action is generally assumed if there is evidence that the chemicals act by different mechanisms. Several questions arise about the potential for misclassification error in the mixture risk prediction. If a common AOP has been established, how much error could there be if the same dose-response curve shape is assumed for all chemicals, when the shapes truly differ and, conversely, what is the error potential if different shapes are assumed when they are not? In particular, how do those concerns impact the choice of index chemical and uncertainty of the RPF-estimated mixture response? What is the quantitative impact if dose additivity is assumed when complete or partial independence actually holds and vice versa? These concepts and implications will be presented with numerical examples in the context of uncertainty of the RPF-estimated mixture response,

  17. An assessment of the radiological impact of the Windscale reactor fire, October 1957.

    PubMed

    Crick, M J; Linsley, G S

    1984-11-01

    On the 10th and 11 October 1957 a fire in the No 1 Pile at the Windscale establishment in Cumbria led to an uncontrolled release of activity to the atmosphere. The resultant cloud subsequently dispersed and radionuclides could be detected over England, Wales and parts of northern Europe. The extensive environmental measurements which were made during and after the release enabled a fairly accurate estimate to be made of the radiation doses to the most exposed individuals in the local population. Until recently, no estimates of the population dose resulting from the release had been published. This paper describes assessments which have been made by the NRPB of the population or collective dose from the release and of the possible associated health impact. In addition to the fission products that escaped, radionuclides were released from materials undergoing irradiation in the pile at the time of the fire. The assessment has included the results of a review of previously unpublished data which established the quantity of these nuclides released and considers their impact on both individual and population doses. The collective effective dose equivalent commitment from the release is estimated to have been 2.0 x 10(3) man Sv. The route of exposure which contributed the most to the collective dose was the inhalation pathway. Iodine-131 was the most important radionuclide, contributing nearly all of the collective dose to the thyroid and a large part of the collective effective dose. Polonium-210 and caesium-137 also made significant contributions; that from caesium-137 came in the longer term via external irradiation from ground deposits and the ingestion of contaminated foodstuffs. The methodology used in the study has been validated to a certain degree by comparing the predicted levels of individual thyroid activity and those measured directly in the weeks following the accident in London, Leeds and Cumbria.

  18. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    PubMed

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  19. Naturally occurring radioactive materials (NORM) in ashes from a fuel-oil power plant in Cienfuegos, Cuba, and the associated radiation hazards.

    PubMed

    Alonso-Hernández, C M; Bernal-Castillo, J; Morera-Gómez, Y; Guillen-Arruebarrena, A; Cartas-Aguila, H A; Acosta-Milián, R

    2014-03-01

    The radioactivity of NORM was measured in ashes collected from a fuel-oil power plant in Cienfuegos, Cuba, using an HPGe gamma-ray spectrometer. The (226)Ra, (210)Pb, (40)K, (232)Th and (238)U activity concentrations reached 240, 77, 59, 70 and 15 Bq kg(-1), respectively. The potential radiological hazard of these residuals was assessed. The radium equivalent activities of the samples varied from 54 to 345 Bq kg(-1). The gamma index was calculated to be lower than that of the reference values, and the gamma absorbed dose rate was higher than the average reported for the earth's crust; however, the assessed annual effective dose was slightly lower than the annual effective dose limit for public, i.e. 1 mSv. Therefore, these bottom ashes were not dramatically enriched with radionuclides and may be used as an additive for building materials without restrictions from a radiological protection point of view.

  20. Regulatory Decisions on Endocrine Disrupting Chemicals Should be Based on the Principles of Endocrinology

    PubMed Central

    Vandenberg, Laura N.; Colborn, Theo; Hayes, Tyrone B.; Heindel, Jerrold J.; Jacobs, David R.; Lee, Duk-Hee; Myers, John Peterson; Shioda, Toshi; Soto, Ana M.; vom Saal, Frederick S.; Welshons, Wade V.; Zoeller, R. Thomas

    2013-01-01

    For years, scientists from various disciplines have studied the effects of endocrine disrupting chemicals (EDCs) on the health and wellbeing of humans and wildlife. Some studies have specifically focused on the effects of low doses, i.e. those in the range that are thought to be safe for humans and/or animals. Others have focused on the existence of non-monotonic dose-response curves. These concepts challenge the way that chemical risk assessment is performed for EDCs. Continued discussions have clarified exactly what controversies and challenges remain. We address several of these issues, including why the study and regulation of EDCs should incorporate endocrine principles; what level of consensus there is for low dose effects; challenges to our understanding of non-monotonicity; and whether EDCs have been demonstrated to produce adverse effects. This discussion should result in a better understanding of these issues, and allow for additional dialogue on their impact on risk assessment. PMID:23411111

  1. On use of the multistage dose-response model for assessing laboratory animal carcinogenicity

    PubMed Central

    Nitcheva, Daniella; Piegorsch, Walter W.; West, R. Webster

    2007-01-01

    We explore how well a statistical multistage model describes dose-response patterns in laboratory animal carcinogenicity experiments from a large database of quantal response data. The data are collected from the U.S. EPA’s publicly available IRIS data warehouse and examined statistically to determine how often higher-order values in the multistage predictor yield significant improvements in explanatory power over lower-order values. Our results suggest that the addition of a second-order parameter to the model only improves the fit about 20% of the time, while adding even higher-order terms apparently does not contribute to the fit at all, at least with the study designs we captured in the IRIS database. Also included is an examination of statistical tests for assessing significance of higher-order terms in a multistage dose-response model. It is noted that bootstrap testing methodology appears to offer greater stability for performing the hypothesis tests than a more-common, but possibly unstable, “Wald” test. PMID:17490794

  2. DNA reactivity as a mode of action and its relevance to cancer risk assessment.

    PubMed

    Preston, R Julian

    2013-02-01

    The ability of a chemical to induce mutations has long been a driver in the cancer risk assessment process. The default strategy has been that mutagenic chemicals demonstrate linear cancer dose responses, especially at low exposure levels. In the absence of additional confounding information, this is a reasonable approach, because risk assessment is appropriately considered as being protective of human health. The concept of mode of action has allowed for an opportunity to move off this default position; mutagenicity is now not considered as the driver but rather the mode of action is. In a more precise way, it is the set of key events that define a mode of action that is fundamental in defining the shape of a cancer dose response. A key event is an informative bioindicator of the cancer response and as such should be predictive of the tumor response, at least in a qualitative way. A clear example of the use of key events in cancer risk assessment is for DNA reactive chemicals. A series of such key events is initiated by the production of DNA damage in target cells from direct interaction of the chemical with DNA leading to the production of mutations by misreplication that results in enhanced cell replication. This enhanced cell replication eventually leads to the development of preneoplastic cells and ultimately overt neoplasms. The response of each of these key events to dose of the chemical can inform the cancer dose-response curve shape. Thus, the dose-response curve for any DNA-reactive chemical can be predicted from knowledge of its mode of action and the behavior of the induced key events.

  3. Dose-response study of topical allyl isothiocyanate (mustard oil) as a human surrogate model of pain, hyperalgesia, and neurogenic inflammation.

    PubMed

    Andersen, Hjalte H; Lo Vecchio, Silvia; Gazerani, Parisa; Arendt-Nielsen, Lars

    2017-09-01

    Despite being a ubiquitous animal pain model, the natural TRPA1-agonist allyl isothiocyanate (AITC, also known as "mustard oil") has only been sparsely investigated as a potential human surrogate model of pain, sensitization, and neurogenic inflammation. Its dose-response as an algogenic, sensitizing irritant remains to be elucidated in human skin. Three concentrations of AITC (10%, 50%, and 90%) and vehicle (paraffin) were applied for 5 minutes to 3 × 3 cm areas on the volar forearms in 14 healthy volunteers, and evoked pain intensity (visual analog scale 0-100 mm) and pain quality were assessed. In addition, a comprehensive battery of quantitative sensory tests was conducted, including assessment of mechanical and thermal sensitivity. Neurogenic inflammation was quantified using full-field laser perfusion imaging. Erythema and hyperpigmentation were assessed before, immediately after, and ≈64 hours after AITC exposure. AITC induced significant dose-dependent, moderate-to-severe spontaneous burning pain, mechanical and heat hyperalgesia, and dynamic mechanical allodynia (P < 0.05). No significant differences in induced pain hypersensitivity were observed between the 50% and 90% AITC concentrations. Acute and prolonged inflammation was evoked by all concentrations, and assessments by full-field laser perfusion imaging demonstrated a significant dose-dependent increase with a ceiling effect from 50% to 90%. Topical AITC application produces pain and somatosensory sensitization in a dose-dependent manner with optimal concentrations recommended to be >10% and ≤50%. The model is translatable to humans and could be useful in pharmacological proof-of-concept studies of TRPA1-antagonists, analgesics, and anti-inflammatory compounds or for exploratory clinical purposes, eg, loss- or gain-of-function in peripheral neuropathies.

  4. Booster dose vaccination for preventing hepatitis B.

    PubMed

    Poorolajal, Jalal; Hooshmand, Elham

    2016-06-07

    Antibodies against hepatitis B surface antigen (HBsAg) wane over time following hepatitis B immunisation; hence, it is unclear whether people vaccinated in three-dose or four-dose schedules of the hepatitis B vaccine are still immune when the hepatitis B surface antibody (anti-HBs) level in their body is undetectable, or lower than the level usually considered protective. This question may potentially be answered indirectly by measuring the anamnestic immune response to a booster dose of vaccine. The term 'booster' (or revaccination) refers to an additional dose of hepatitis B vaccine (HBV) given some time post-primary vaccination to induce immune memory and improve protection against hepatitis B virus (HBV) infection. To assess the benefits and harms of booster dose hepatitis B vaccination, more than five years after the primary vaccination, for preventing HBV infection in healthy individuals previously vaccinated with the hepatitis B vaccine, and with hepatitis B surface antibody (anti-HBs) levels below 10 mIU/mL. We searched the Cochrane Hepato-Biliary Group Controlled Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Science Citation Index Expanded, conference databases, and reference lists of articles to January 2016. We also contacted authors of articles. In addition, we searched ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing trials (May 2016). Randomised clinical trials addressing anamnestic immune response to a booster dose of hepatitis B vaccine, more than five years after the primary vaccination, in apparently healthy participants, vaccinated in a three-dose or four-dose schedule of the hepatitis B vaccine during the primary vaccination, without receiving an additional dose or immunoglobulin. Both review authors decided if the identified studies met the inclusion criteria or not. Primary outcomes included the proportion of participants with anamnestic immune response in non-protected participants and signs of HBV infection. Secondary outcomes were the proportion of participants that developed local and systemic adverse events following a booster dose injection. We planned to report the weighted proportion with 95% confidence intervals (CIs). There were no eligible randomised clinical trials fulfilling the inclusion criteria of this review. We were unable to include any randomised clinical trials on the topic; only randomised clinical trials will be able to provide an answer as to whether a booster dose vaccination is able to protect against hepatitis B infection.

  5. Impact of TGF for aircrew dosimetry: analysis of continuous onboard measurements

    NASA Astrophysics Data System (ADS)

    Trompier, Francois; Fuller, Nicolas; Bonnotte, Frank; Desmaris, Gérard; Musso, Angelica; Cale, Eric; Bottollier-Depois, Jean-François

    2014-05-01

    The actual assessment of the occupational exposure of aircrew to cosmic radiation is performed in routine by software based on the crossing of route flight data with dose rate maps of the atmosphere obtained by simulation or elaborated with model based on measured data. In addition of the galactic component, some of these softwares take into account also the possible increase of dose from solar flares. In several publications, terrestrial gamma-rays flashes (TGF) are also investigated as a possible source of exposure of aircrew. Up to now, the evaluation of the impact of TGF in terms of dose onboard aircraft has been performed only by calculation. According to these publications, if the airplane is located in or near the high-field region during the lightning discharge, doses could reach the order of 100 of mSv, which far exceed the annual dose limit for workers (1). To our knowledge, no measured data has been yet reported for such phenomena that could confirm or not the order of magnitude of dose from TGF or the frequency or the probability of occurrence of such phenomena. To investigate further the TGF effect, it is recommended to perform measurements onboard airplanes. Since the beginning of 2013, the Institute of Radiation Protection and nuclear Safety (IRSN) in cooperation with Air France is running a campaign of continuous measurements with active devices aiming to measure effect on dose rate of solar flare. These measurements are used to improve models used to estimate the doses from Ground Level Event (GLE). In addition, passive dosimeters were historically installed in Air France airplanes and read out every three months constituting a very large database of dose measurements. All these data will be analyzed to better characterize the possible influence on dose from TGF. The statistical analysis of these data offers the possibility to estimate the order of magnitude of possible additional doses to aircrew due to TGF and/or to evaluate the probability of occurrence of TGF events impacting significantly the exposure of aircrew. (1) J. R. Dwyer et al. Estimation of the fluence of high-energy electron bursts produced by thunderclouds and the resulting radiation doses received in aircraft JOURNAL OF GEOPHYSICAL RESEARCH, VOL. 115, D09206, 10 PP., 2010, doi:10.1029/2009JD012039

  6. Clinical Impact of Additional Cytogenetic Aberrations, cKIT and RAS Mutations, and Treatment Elements in Pediatric t(8;21)-AML: Results From an International Retrospective Study by the International Berlin-Frankfurt-Münster Study Group

    PubMed Central

    Klein, Kim; Kaspers, Gertjan; Harrison, Christine J.; Beverloo, H. Berna; Reedijk, Ardine; Bongers, Mathilda; Cloos, Jacqueline; Pession, Andrea; Reinhardt, Dirk; Zimmerman, Martin; Creutzig, Ursula; Dworzak, Michael; Alonzo, Todd; Johnston, Donna; Hirsch, Betsy; Zapotocky, Michal; De Moerloose, Barbara; Fynn, Alcira; Lee, Vincent; Taga, Takashi; Tawa, Akio; Auvrignon, Anne; Zeller, Bernward; Forestier, Erik; Salgado, Carmen; Balwierz, Walentyna; Popa, Alexander; Rubnitz, Jeffrey; Raimondi, Susana; Gibson, Brenda

    2015-01-01

    Purpose This retrospective cohort study aimed to determine the predictive relevance of clinical characteristics, additional cytogenetic aberrations, and cKIT and RAS mutations, as well as to evaluate whether specific treatment elements were associated with outcomes in pediatric t(8;21)-positive patients with acute myeloid leukemia (AML). Patients and Methods Karyotypes of 916 pediatric patients with t(8;21)-AML were reviewed for the presence of additional cytogenetic aberrations, and 228 samples were screened for presence of cKIT and RAS mutations. Multivariable regression models were used to assess the relevance of anthracyclines, cytarabine, and etoposide during induction and overall treatment. End points were the probability of achieving complete remission, cumulative incidence of relapse (CIR), probability of event-free survival, and probability of overall survival. Results Of 838 patients included in final analyses, 92% achieved complete remission. The 5-year overall survival, event-free survival, and CIR were 74%, 58%, and 26%, respectively. cKIT mutations and RAS mutations were not significantly associated with outcome. Patients with deletions of chromosome arm 9q [del(9q); n = 104] had a lower probability of complete remission (P = .01). Gain of chromosome 4 (+4; n = 21) was associated with inferior CIR and survival (P < .01). Anthracycline doses greater than 150 mg/m2 and etoposide doses greater than 500 mg/m2 in the first induction course and high-dose cytarabine 3 g/m2 during induction were associated with better outcomes on various end points. Cumulative doses of cytarabine greater than 30 g/m2 and etoposide greater than 1,500 mg/m2 were associated with lower CIR rates and better probability of event-free survival. Conclusion Pediatric patients with t(8;21)-AML and additional del(9q) or additional +4 might not be considered at good risk. Patients with t(8;21)-AML likely benefit from protocols that have high doses of anthracyclines, etoposide, and cytarabine during induction, as well as from protocols comprising cumulative high doses of cytarabine and etoposide. PMID:26573082

  7. Beneficial effects of Korean red ginseng on lymphocyte DNA damage, antioxidant enzyme activity, and LDL oxidation in healthy participants: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Kim, Ji Young; Park, Ju Yeon; Kang, Hee Jung; Kim, Oh Yoen; Lee, Jong Ho

    2012-07-17

    The reported health benefits of Korean red ginseng (KRG) include antioxidant, antitumor, antimutagenic, and immunomodulatory activities; however, the effects on oxidative stress have not yet been evaluated. Therefore, we assessed the effect of KRG on antioxidant enzymes and oxidative stress markers in humans. We conducted a randomized, double-blind, placebo-controlled study with three groups, including placebo, low-dose (3 g/day), and high-dose (6 g/day), which were randomly assigned to healthy subjects aged 20-65 years. Lymphocyte DNA damage, antioxidative enzyme activity, and lipid peroxidation were assessed before and after the 8-week supplementation. Fifty-seven subjects completed the protocol. Plasma superoxide dismutase (SOD) activity after the 8-week KRG supplementation was significantly higher in the low-and high-dose groups compared to baseline. Plasma glutathione peroxidase (GPx) and catalase activities were also increased after the high-dose supplementation. Furthermore, the DNA tail length and tail moment were significantly reduced after the supplementation (low-dose and high-dose), and plasma oxidized low-density lipoprotein (LDL) levels were reduced in low-dose and high-dose groups, but increased in the placebo group. The net changes in oxidized LDL after the supplementation differed significantly between both KRG supplementation groups and the placebo group. Net changes in GPx, SOD and catalase activities, and DNA tail length and tail moment were significantly different between the high-dose group and the placebo group. Additionally, the net changes in urinary 8-epi-PGF(2α) were significantly different between the KRG supplementation groups and the placebo group. KRG supplementation may attenuate lymphocyte DNA damage and LDL oxidation by upregulating antioxidant enzyme activity.

  8. SU-E-J-101: Retroactive Calculation of TLD and Film Dose in Anthropomorphic Phantom as Assessment of Updated TPS Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alkhatib, H; Oves, S

    Purpose: To demonstrate a quick and comprehensive method verifying the accuracy of the updated dose model by recalculating dose distribution in an anthropomorphic phantom with a new version of the TPS and comparing the results to measured values. Methods: CT images and IMRT plan of an RPC anthropomorphic head phantom, previously calculated by Pinnacle 9.0, was re-computed using Pinnacle 9.2 and 9.6. The dosimeters within the phantom include four TLD capsules representing a primary PTV, two TLD capsules representing a secondary PTV, and two TLD capsules representing an organ at risk. Also included were three sheets of Gafchromic film. Performancemore » of the updated TPS version was assessed by recalculating point doses and dose profiles corresponding to TLD and film position respectively and then comparing the results to reported values by the RPC. Results: Comparing calculated doses to reported measured doses from the RPC yielded an average disagreement of 1.48%, 2.04% and 2.10% for versions 9.0, 9.2, 9.6 respectively. Computed doses points all meet the RPC's passing criteria with the exception of the point representing the superior organ at risk in version 9.6. However, qualitative analysis of the recalculated dose profiles showed improved agreement with those of the RPC, especially in the penumbra region. Conclusion: This work has demonstrated the calculation results of Pinnacle 9.2 and 9.6 vs 9.0 version. Additionally, this study illustrates a method for the user to gain confidence upgrade to a newer version of the treatment planning system.« less

  9. Beneficial effects of Korean red ginseng on lymphocyte DNA damage, antioxidant enzyme activity, and LDL oxidation in healthy participants: a randomized, double-blind, placebo-controlled trial

    PubMed Central

    2012-01-01

    Background The reported health benefits of Korean red ginseng (KRG) include antioxidant, antitumor, antimutagenic, and immunomodulatory activities; however, the effects on oxidative stress have not yet been evaluated. Therefore, we assessed the effect of KRG on antioxidant enzymes and oxidative stress markers in humans. Methods We conducted a randomized, double-blind, placebo-controlled study with three groups, including placebo, low-dose (3 g/day), and high-dose (6 g/day), which were randomly assigned to healthy subjects aged 20–65 years. Lymphocyte DNA damage, antioxidative enzyme activity, and lipid peroxidation were assessed before and after the 8-week supplementation. Results Fifty-seven subjects completed the protocol. Plasma superoxide dismutase (SOD) activity after the 8-week KRG supplementation was significantly higher in the low-and high-dose groups compared to baseline. Plasma glutathione peroxidase (GPx) and catalase activities were also increased after the high-dose supplementation. Furthermore, the DNA tail length and tail moment were significantly reduced after the supplementation (low-dose and high-dose), and plasma oxidized low-density lipoprotein (LDL) levels were reduced in low-dose and high-dose groups, but increased in the placebo group. The net changes in oxidized LDL after the supplementation differed significantly between both KRG supplementation groups and the placebo group. Net changes in GPx, SOD and catalase activities, and DNA tail length and tail moment were significantly different between the high-dose group and the placebo group. Additionally, the net changes in urinary 8-epi-PGF2α were significantly different between the KRG supplementation groups and the placebo group. Conclusions KRG supplementation may attenuate lymphocyte DNA damage and LDL oxidation by upregulating antioxidant enzyme activity. PMID:22805313

  10. Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality

    PubMed Central

    Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T

    2016-01-01

    Background Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. Purpose To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Material and Methods Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. Results There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. Conclusion There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality. PMID:27583169

  11. Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality.

    PubMed

    Østerås, Bjørn Helge; Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T

    2016-08-01

    Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor's water phantom. There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between -3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and -7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.

  12. Incidence of oral thrush in patients with COPD prescribed inhaled corticosteroids: Effect of drug, dose, and device.

    PubMed

    Dekhuijzen, P N Richard; Batsiou, Maria; Bjermer, Leif; Bosnic-Anticevich, Sinthia; Chrystyn, Henry; Papi, Alberto; Rodríguez-Roisin, Roberto; Fletcher, Monica; Wood, Lucy; Cifra, Alessandra; Soriano, Joan B; Price, David B

    2016-11-01

    Little information is available on real-life occurrence of oral thrush in COPD patients treated with ICS. We investigated oral thrush incidence in COPD patients prescribed FDC ICS/LABA therapies and assessed whether it is modulated by the ICS type, dose, and delivery device. We conducted a historical, observational, matched cohort study (one baseline year before and one outcome year after initiation of therapy) using data from the UK Optimum Patient Care Research Database. We assessed oral thrush incidence in patients initiating long-acting bronchodilators or FDC ICS/LABA therapy. We then compared different combination therapies (budesonide/formoterol fumarate dihydrate [BUD/FOR] and fluticasone propionate/salmeterol xinafoate [FP/SAL]) and devices (DPI and pMDI). Patients prescribed FDC ICS/LABA had significantly greater odds of experiencing oral thrush than those prescribed long-acting bronchodilators alone (adjusted OR 2.18 [95% CI 1.84-2.59]). Significantly fewer patients prescribed BUD/FOR DPI developed oral thrush compared with FP/SAL DPI (OR 0.77 [0.63-0.94]) when allowing for differences in prescribed doses between the drugs. A significantly smaller proportion of patients developed oral thrush in the FP/SAL pMDI arm than in the FP/SAL DPI arm (OR 0.67 [0.55-0.82]). Additionally, in the FP/SAL cohort (both DPI and pMDI), increased risk of oral thrush was significantly associated with high ICS daily dose (OR 1.97 [1.22-3.17] vs low daily dose). ICS use increases oral thrush incidence in COPD and this effect is dose-dependent for FP/SAL therapies. Of the therapies assessed, FP/SAL pMDI and BUD/FOR DPI may be more protective against oral thrush. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A phase I dose-escalation study to a predefined dose of a transforming growth factor-β1 monoclonal antibody (TβM1) in patients with metastatic cancer

    PubMed Central

    COHN, ALLEN; LAHN, MICHAEL M.; WILLIAMS, KRISTEN E.; CLEVERLY, ANN L.; PITOU, CELINE; KADAM, SUNIL K.; FARMEN, MARK W.; DESAIAH, DURISALA; RAJU, ROBERT; CONKLING, PAUL; RICHARDS, DONALD

    2014-01-01

    Transforming growth factor β (TGF-β) plays an important role in cancer. Monoclonal antibodies (mAb) designed to specifically block the TGF-β ligands, are expected to inhibit tumor progression in patients with metastatic cancer. TβM1 is a humanized mAb optimized for neutralizing activity against TGF-β1. The objective of this clinical trial was to assess the safety and tolerability of TβM1 in patients with metastatic cancer. In this phase I, uncontrolled, non-randomized, dose-escalation study, 18 eligible adult patients who had measurable disease per RECIST and a performance status of ≤2 on the ECOG scale were administered TβM1 intravenously over 10 min at doses of 20, 60, 120 and 240 mg on day 1 of each 28-day cycle. Safety was assessed by adverse events (as defined by CTCAE version 3.0) and possible relationship to study drug, dose-limiting toxicities and laboratory changes. Systemic drug exposure and pharmacodynamic (PD) parameters were assessed. TβM1 was safe when administered once monthly. The pharmacokinetic (PK) profile was consistent with a mAb with a mean elimination half-life approximately 9 days. Although anticipated changes in PD markers such as serum VEGF, bFGF and mRNA expression of SMAD7 were observed in whole-blood, suggesting activity of TβM1 on the targeted pathway, these changes were not consistent to represent a PD effect. Additionally, despite the presence of an activated TGF-β1 expression signature in patients’ whole blood, the short dosing duration did not translate into significant antitumor effect in the small number of patients investigated in this study PMID:25270361

  14. Reduction of severe visual loss and complications following intra-arterial chemotherapy (IAC) for refractory retinoblastoma.

    PubMed

    Reddy, M Ashwin; Naeem, Zishan; Duncan, Catriona; Robertson, Fergus; Herod, Jane; Rennie, Adam; Liasis, Alki; Thompson, Dorothy Ann; Sagoo, Mandeep

    2017-12-01

    Intra-arterial chemotherapy (IAC) for retinoblastoma has been documented as causing visual loss and ocular motility problems. A lack of safety data has precluded its acceptance in all centres. Retrospective cohort study of patients with retinoblastoma from 2013 to 2015 who had a healthy foveola and relapsed following systemic chemotherapy. All required IAC. The correlation of complications with doses of melphalan +/- topotecan used and putative catheterisation complications was assessed. Ocular complications were determined using vision, macular (including pattern visual evoked potentials (PVEPs)), retinal electroretinograms (ERGs) and ocular motility functions. Efficacy (tumour control) was also assessed. All eyes had age appropriate doses of melphalan with five having additional doses of topotecan. Severe physiological reactions requiring adrenaline were seen in six patients during the catheterisation procedure. Difficulty was documented in accessing the ophthalmic artery in 7/27 catheterisations. The median/mean number of courses of chemotherapy was three. No child had severe visual loss as assessed by age appropriate tests (median follow-up 20.9 months, range 3.7-35.2 months). One child had nasal choroidal ischaemia and a sixth nerve palsy. Post-IAC PVEPs were performed in eight and reported as normal. All post-IAC ERGs were normal apart from one (total dose 20 mg melphalan 0.8 mg topotecan). Tumour control was achieved in six of nine cases. The proportion of visual and ocular motility complications may be reduced by providing age-adjusted doses of melphalan. Dose rather than complications from catheterisation is the most important risk factor for ocular injury. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Simulation-Based Evaluation of Dose-Titration Algorithms for Rapid-Acting Insulin in Subjects with Type 2 Diabetes Mellitus Inadequately Controlled on Basal Insulin and Oral Antihyperglycemic Medications.

    PubMed

    Ma, Xiaosu; Chien, Jenny Y; Johnson, Jennal; Malone, James; Sinha, Vikram

    2017-08-01

    The purpose of this prospective, model-based simulation approach was to evaluate the impact of various rapid-acting mealtime insulin dose-titration algorithms on glycemic control (hemoglobin A1c [HbA1c]). Seven stepwise, glucose-driven insulin dose-titration algorithms were evaluated with a model-based simulation approach by using insulin lispro. Pre-meal blood glucose readings were used to adjust insulin lispro doses. Two control dosing algorithms were included for comparison: no insulin lispro (basal insulin+metformin only) or insulin lispro with fixed doses without titration. Of the seven dosing algorithms assessed, daily adjustment of insulin lispro dose, when glucose targets were met at pre-breakfast, pre-lunch, and pre-dinner, sequentially, demonstrated greater HbA1c reduction at 24 weeks, compared with the other dosing algorithms. Hypoglycemic rates were comparable among the dosing algorithms except for higher rates with the insulin lispro fixed-dose scenario (no titration), as expected. The inferior HbA1c response for the "basal plus metformin only" arm supports the additional glycemic benefit with prandial insulin lispro. Our model-based simulations support a simplified dosing algorithm that does not include carbohydrate counting, but that includes glucose targets for daily dose adjustment to maintain glycemic control with a low risk of hypoglycemia.

  16. Combined Exposure to Anti-Androgens Exacerbates Disruption of Sexual Differentiation in the Rat

    PubMed Central

    Hass, Ulla; Scholze, Martin; Christiansen, Sofie; Dalgaard, Majken; Vinggaard, Anne Marie; Axelstad, Marta; Metzdorff, Stine Broeng; Kortenkamp, Andreas

    2007-01-01

    Objective The aim of this study was to assess whether the joint effects of three androgen receptor antagonists (vinclozolin, flutamide, procymidone) on male sexual differentiation after in utero and postnatal exposures can be predicted based on dose–response data of the individual chemicals. Methods Test chemicals and mixtures were administered by gavage to time-mated nulliparous, young adult Wistar rats from gestational day 7 to the day before expected birth, and from postnatal days 1–16. Changes in anogenital distance (AGD) and nipple retention (NR) in male offspring rats were chosen as end points for extensive dose–response studies. Vinclozolin, flutamide, and procymidone were combined at a mixture ratio proportional to their individual potencies for causing retention of six nipples in male offspring. Results With AGD as the end point, the joint effects of the three anti-androgens were essentially dose additive. The observed responses for NR were slightly higher than those expected on the basis of dose addition. A combination of doses of each chemical, which on its own did not produce statistically significant AGD alterations, induced half-maximal mixture effects. At individual doses associated with only modest effects on NR, the mixture induced NR approaching female values in the males. Conclusions Effects of a mixture of similarly acting anti-androgens can be predicted fairly accurately on the basis of the potency of the individual mixture components by using the dose addition concept. Exposure to anti-androgens, which individually appears to exert only small effects, may induce marked responses in concert with, possibly unrecognized, similarly acting chemicals. PMID:18174960

  17. Systematic Review and Meta-Analysis: Dose-Response Relationship of Selective Serotonin Reuptake Inhibitors in Major Depressive Disorder.

    PubMed

    Jakubovski, Ewgeni; Varigonda, Anjali L; Freemantle, Nicholas; Taylor, Matthew J; Bloch, Michael H

    2016-02-01

    Previous studies suggested that the treatment response to selective serotonin reuptake inhibitors (SSRIs) in major depressive disorder follows a flat response curve within the therapeutic dose range. The present study was designed to clarify the relationship between dosage and treatment response in major depressive disorder. The authors searched PubMed for randomized placebo-controlled trials examining the efficacy of SSRIs for treating adults with major depressive disorder. Trials were also required to assess improvement in depression severity at multiple time points. Additional data were collected on treatment response and all-cause and side effect-related discontinuation. All medication doses were transformed into imipramine-equivalent doses. The longitudinal data were analyzed with a mixed-regression model. Endpoint and tolerability analyses were analyzed using meta-regression and stratified subgroup analysis by predefined SSRI dose categories in order to assess the effect of SSRI dosing on the efficacy and tolerability of SSRIs for major depressive disorder. Forty studies involving 10,039 participants were included. Longitudinal modeling (dose-by-time interaction=0.0007, 95% CI=0.0001-0.0013) and endpoint analysis (meta-regression: β=0.00053, 95% CI=0.00018-0.00088, z=2.98) demonstrated a small but statistically significant positive association between SSRI dose and efficacy. Higher doses of SSRIs were associated with an increased likelihood of dropouts due to side effects (meta-regression: β=0.00207, 95% CI=0.00071-0.00342, z=2.98) and decreased likelihood of all-cause dropout (meta-regression: β=-0.00093, 95% CI=-0.00165 to -0.00021, z=-2.54). Higher doses of SSRIs appear slightly more effective in major depressive disorder. This benefit appears to plateau at around 250 mg of imipramine equivalents (50 mg of fluoxetine). The slightly increased benefits of SSRIs at higher doses are somewhat offset by decreased tolerability at high doses.

  18. Anticonvulsant Effect of Guaifenesin against Pentylenetetrazol-Induced Seizure in Mice

    PubMed Central

    Keshavarz, Mojtaba; Showraki, Alireza; Emamghoreishi, Masoumeh

    2013-01-01

    Background: There have been some reports about the possible N-methyl-D-aspartate (NMDA) antagonist activity of Guaifenesin. As drugs with a similar structure to Guaifenesin (i.e. Felbamate) and those with NMDA antagonist activity have been clinically used as anticonvulsants, the aim of this study was to determine whether Guaifenesin has an anticonvulsant effect in an animal model of seizure. Methods: Anticonvulsant effect of Guaifenesin was assessed via Pentylenetetrazol (PTZ)-induced convulsion. Male albino mice received Guaifenesin (100, 200, 300, or 400 mg/kg; n=8-10) or 0.25% Tween (vehicle) intraperitoneally 30 minutes before the injection of PTZ (95 mg/kg). Diazepam (3 mg/kg; n=8) was used as a reference drug. The latency time before the onset of myoclonic, clonic, and tonic-clonic convulsions, percentage of animals exhibiting convulsion, and percentage of mortality were recorded. In addition, the effect of Guaifenesin on neuromuscular coordination was assessed using the Rotarod. Results: Guaifenesin at all the studied doses significantly increased the latency to myoclonic and clonic convulsions in a dose-dependent manner. In addition, Guaifenesin at the dose of 300 mg/kg increased the latency to tonic-clonic seizure. The ED50s of Guaifenesin for protection against PTZ-induced clonic and tonic-clonic seizures and death were 744.88 (360-1540), 256 (178-363), and 328 (262-411) mg/kg, respectively. Guaifenesin at all the investigated doses significantly reduced neuromuscular coordination, compared to the vehicle-treated group. Conclusion: These results suggest that Guaifenesin possesses muscle relaxant and anticonvulsant properties and may have a potential clinical use in absence seizure. PMID:23825891

  19. Anticonvulsant Effect of Guaifenesin against Pentylenetetrazol-Induced Seizure in Mice.

    PubMed

    Keshavarz, Mojtaba; Showraki, Alireza; Emamghoreishi, Masoumeh

    2013-06-01

    There have been some reports about the possible N-methyl-D-aspartate (NMDA) antagonist activity of Guaifenesin. As drugs with a similar structure to Guaifenesin (i.e. Felbamate) and those with NMDA antagonist activity have been clinically used as anticonvulsants, the aim of this study was to determine whether Guaifenesin has an anticonvulsant effect in an animal model of seizure. Anticonvulsant effect of Guaifenesin was assessed via Pentylenetetrazol (PTZ)-induced convulsion. Male albino mice received Guaifenesin (100, 200, 300, or 400 mg/kg; n=8-10) or 0.25% Tween (vehicle) intraperitoneally 30 minutes before the injection of PTZ (95 mg/kg). Diazepam (3 mg/kg; n=8) was used as a reference drug. The latency time before the onset of myoclonic, clonic, and tonic-clonic convulsions, percentage of animals exhibiting convulsion, and percentage of mortality were recorded. In addition, the effect of Guaifenesin on neuromuscular coordination was assessed using the Rotarod. Guaifenesin at all the studied doses significantly increased the latency to myoclonic and clonic convulsions in a dose-dependent manner. In addition, Guaifenesin at the dose of 300 mg/kg increased the latency to tonic-clonic seizure. The ED50s of Guaifenesin for protection against PTZ-induced clonic and tonic-clonic seizures and death were 744.88 (360-1540), 256 (178-363), and 328 (262-411) mg/kg, respectively. Guaifenesin at all the investigated doses significantly reduced neuromuscular coordination, compared to the vehicle-treated group. These results suggest that Guaifenesin possesses muscle relaxant and anticonvulsant properties and may have a potential clinical use in absence seizure.

  20. SU-F-J-104: Weekly MRI for Dose Assessment of Organs at Risk During Treatment of HN Cancer of the Oropharynx

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, K; Li, J; Venigalla, P

    2016-06-15

    Purpose: Investigate the feasibility of using weekly MRI to assess dose to organs at risk utilizing deformable image registration. Methods: Sixteen H&N patients with oropharyngeal cancer were imaged on a 3T MR scanner using T2W and mDIXON sequence. Patients were imaged on a weekly basis in treatment position. Parotids (LP & RP), submandibular glands (LS, RS), and oral cavity (OC) were delineated on the weekly MR and reviewed by a board certified radiation oncologist. The original planning CT (pCT), RT-Dose, and RT-Structures were deformed and registered to each weekly MRIs. The deformed CTs and RT-Structures were imported to the treatmentmore » planning system (TPS) and rigidly registered to the pCT. Forward dose calculation of the original RT-Plan was used to estimate the delivered dose on the deformed CT. The dose volume histograms (DVH) statistics were performed to compare planned dose, deformed dose, and forward calculated dose. In addition, Dice similarity metric (DSM) was used to compare deformed and reference structures. Results: The average (min,max) DSM between deformed and reference structures was 0.71 (0.69,0.93); 0.70 (0.64,0.89); 0.65 (0.48,0.86); 0.63 (0.37,0.89); and 0.63 (0.58,0.87); for LP, RP, LS, RS, and OC respectively. The respective average relative structures volumes changed at a weekly rate of −4.99%; −4.40%; +3.45%; +1.46%; −1.39%, respectively. The percentage difference %(min,max) between estimated delivered dose and planned dose was +3.94 (−51.3,+30.5); +6.33 (−58.6,+82.7); +2.46 (−38.9,+37.6,); +2.38(−49.0,+28.9); +3.55(−17.0,+43.1). Conclusion: The recalculated dose based on weekly MRI deviated from planned dose for all OARs. Meanwhile, the deformed dose did not reflect the subtle changes in OARs as compared to the recalculated dose. This study demonstrates the feasibility of using weekly MRI to monitor volumetric changes which has important implications on actual delivered dose.« less

  1. Randomized clinical trial assessing whether additional massage treatments for chronic neck pain improve 12- and 26-week outcomes.

    PubMed

    Cook, Andrea J; Wellman, Robert D; Cherkin, Daniel C; Kahn, Janet R; Sherman, Karen J

    2015-10-01

    This is the first study to systematically evaluate the value of a longer treatment period for massage. We provide a framework of how to conceptualize an optimal dose in this challenging setting of nonpharmacologic treatments. The aim was to determine the optimal dose of massage for neck pain. Two-phase randomized trial for persons with chronic nonspecific neck pain. Primary randomization to one of five groups receiving 4 weeks of massage (30 minutes 2x/or 3x/wk or 60 minutes 1x, 2x, or 3x/wk). Booster randomization of participants to receive an additional six massages, 60 minutes 1x/wk, or no additional massage. A total of 179 participants from Group Health and the general population of Seattle, WA, USA recruited between June 2010 and August 2011 were included. Primary outcomes self-reported neck-related dysfunction (Neck Disability Index) and pain (0-10 scale) were assessed at baseline, 12, and 26 weeks. Clinically meaningful improvement was defined as greater than or equal to 5-point decrease in dysfunction and greater than or equal to 30% decrease in pain from baseline. Clinically meaningful improvement for each primary outcome with both follow-up times was analyzed using adjusted modified Poisson generalized estimating equations (GEEs). Secondary analyses for the continuous outcomes used linear GEEs. There were no observed differences by primary treatment group at 12 or 26 weeks. Those receiving booster dose had improvements in both dysfunction and pain at 12 weeks (dysfunction: relative risk [RR]=1.56 [1.08-2.25], p=.018; pain: RR=1.25 [0.98-1.61], p=.077), but those were nonsignificant at 26 weeks (dysfunction: RR=1.22 [0.85-1.74]; pain: RR=1.09 [0.82-1.43]). Subgroup analysis by primary and booster treatments found the booster dose only effective among those initially randomized to one of the 60-minute massage groups. "Booster" doses for those initially receiving 60 minutes of massage should be incorporated into future trials of massage for chronic neck pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    PubMed

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  3. Assessment of tritium in the Savannah River Site environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlton, W.H.; Murphy, C.E. Jr.; Bauer, L.R.

    1993-10-01

    This report is the first revision to a series of reports on radionuclides inn the SRS environment. Tritium was chosen as the first radionuclide in the series because the calculations used to assess the dose to the offsite population from SRS releases indicate that the dose due to tritium, through of small consequence, is one of the most important the radionuclides. This was recognized early in the site operation, and extensive measurements of tritium in the atmosphere, surface water, and ground water exist due to the effort of the Environmental Monitoring Section. In addition, research into the transport and fatemore » of tritium in the environment has been supported at the SRS by both the local Department of Energy (DOE) Office and DOE`s Office of Health and Environmental Research.« less

  4. Measuring treatment compliance of men with non-gonococcal urethritis receiving oxytetracycline combined with low dose phenobarbitone.

    PubMed Central

    Bignell, C J; Mulcahy, F M; Peaker, S; Pullar, T; Feely, M P

    1988-01-01

    Of 62 men with non-gonococcal urethritis who entered a study to assess compliance with treatment with oxytetracycline, only 33 could be evaluated. Traditional methods (interview and the absence of oxytetracycline in the urine) showed incomplete compliance in nine. Use of low dose phenobarbitone as a pharmacological marker showed incomplete compliance in a further five patients. In addition, phenobarbitone concentrations gave information on the extent to which individual patients had omitted treatment and provided direct, as opposed to circumstantial, evidence of good compliance by most (18) of those studied. Only three of the 33 patients whose compliance was assessed had evidence of continuing infection at follow up, and there was evidence of incomplete compliance in only one of these patients. PMID:3203931

  5. Ultra low-dose CT attenuation correction in PET SPM

    NASA Astrophysics Data System (ADS)

    Wang, Shyh-Jen; Yang, Bang-Hung; Tsai, Chia-Jung; Yang, Ching-Ching; Lee, Jason J. S.; Wu, Tung-Hsin

    2010-07-01

    The use of CT images for attenuation correction (CTAC) allows significantly shorter scanning time and a high quality noise-free attenuation map compared with conventional germanium-68 transmission scan because at least 10 4 times greater of photon flux would be generated from a CT scan under standard operating condition. However, this CTAC technique would potentially introduce more radiation risk to the patients owing to the higher radiation exposure from CT scan. Statistic parameters mapping (SPM) is a prominent technique in nuclear medicine community for the analysis of brain imaging data. The purpose of this study is to assess the feasibility of low-dose CT (LDCT) and ultra low-dose CT (UDCT) in PET SPM applications. The study was divided into two parts. The first part was to evaluate of tracer uptake distribution pattern and quantity analysis by using the striatal phantom to initially assess the feasibility of AC for clinical purpose. The second part was to examine the group SPM analysis using the Hoffman brain phantom. The phantom study is to simulate the human brain and to reduce the experimental uncertainty of real subjects. The initial studies show that the results of PET SPM analysis have no significant differences between LDCT and UDCT comparing to the current used default CTAC. Moreover, the dose of the LDCT is lower than that of the default CT by a factor of 9, and UDCT can even yield a 42 times dose reduction. We have demonstrated the SPM results while using LDCT and UDCT for PET AC is comparable to those using default CT setting, suggesting their feasibility in PET SPM applications. In addition, the necessity of UDCT in PET SPM studies to avoid excess radiation dose is also evident since most of the subjects involved are non-cancer patients or children and some normal subjects are even served as a comparison group in the experiment. It is our belief that additional attempts to decrease the radiation dose would be valuable, especially for children and normal volunteers, to work towards ALARA (as low as reasonably achievable) concept for PET SPM studies.

  6. Mechanism-based risk assessment strategy for drug-induced cholestasis using the transcriptional benchmark dose derived by toxicogenomics.

    PubMed

    Kawamoto, Taisuke; Ito, Yuichi; Morita, Osamu; Honda, Hiroshi

    2017-01-01

    Cholestasis is one of the major causes of drug-induced liver injury (DILI), which can result in withdrawal of approved drugs from the market. Early identification of cholestatic drugs is difficult due to the complex mechanisms involved. In order to develop a strategy for mechanism-based risk assessment of cholestatic drugs, we analyzed gene expression data obtained from the livers of rats that had been orally administered with 12 known cholestatic compounds repeatedly for 28 days at three dose levels. Qualitative analyses were performed using two statistical approaches (hierarchical clustering and principle component analysis), in addition to pathway analysis. The transcriptional benchmark dose (tBMD) and tBMD 95% lower limit (tBMDL) were used for quantitative analyses, which revealed three compound sub-groups that produced different types of differential gene expression; these groups of genes were mainly involved in inflammation, cholesterol biosynthesis, and oxidative stress. Furthermore, the tBMDL values for each test compound were in good agreement with the relevant no observed adverse effect level. These results indicate that our novel strategy for drug safety evaluation using mechanism-based classification and tBMDL would facilitate the application of toxicogenomics for risk assessment of cholestatic DILI.

  7. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    PubMed

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients <18 years and 17 patients >18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (<18 years) separately by using technical dose descriptors and estimated effective dose. Differences in dose were assessed with the Mann-Whitney U test. The median effective dose for the investigative protocol was 0.04 mSv (95% confidence interval [ CI confidence interval ]: 0.034 mSv, 0.10 mSv) for children and 0.05 mSv (95% CI confidence interval : 0.04 mSv, 0.08 mSv) for adults. These doses were much lower than those with conventional CT (median: 0.52 mSv [95% CI confidence interval : 0.31 mSv, 3.90 mSv] for children and 1.12 mSv [95% CI confidence interval : 0.57 mSv, 3.15 mSv] for adults) and of the same order of magnitude as those for conventional radiography (median: 0.012 mSv [95% CI confidence interval : 0.006 mSv, 0.022 mSv] for children and 0.012 mSv [95% CI confidence interval : 0.005 mSv, 0.031 mSv] for adults). All images were rated at least as diagnostically acceptable. Very good agreement was found in overall Bhalla score ( ICC intraclass correlation coefficient , 0.96) with regard to the severity of bronchiectasis ( ICC intraclass correlation coefficient , 0.87) and sacculations and abscesses ( ICC intraclass correlation coefficient , 0.84). Interobserver agreement was excellent ( ICC intraclass correlation coefficient , 0.86-1). For patients with CF cystic fibrosis , a dedicated chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  8. Lack of Benefit for the Addition of Androgen Deprivation Therapy to Dose-Escalated Radiotherapy in the Treatment of Intermediate- and High-Risk Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krauss, Daniel, E-mail: dkrauss@beaumont.edu; Kestin, Larry; Ye, Hong

    2011-07-15

    Purpose: Assessment of androgen deprivation therapy (ADT) benefits for prostate cancer treated with dose-escalated radiotherapy (RT). Methods and Materials: From 1991 to 2004, 1,044 patients with intermediate- (n = 782) or high-risk (n = 262) prostate cancer were treated with dose-escalated RT at William Beaumont Hospital. Patients received external-beam RT (EBRT) alone, brachytherapy (high or low dose rate), or high dose rate brachytherapy plus pelvic EBRT. Intermediate-risk patients had Gleason score 7, prostate-specific antigen (PSA) 10.0-19.9 ng/mL, or Stage T2b-T2c. High-risk patients had Gleason score 8-10, PSA {>=}20, or Stage T3. Patients were additionally divided specifically by Gleason score, presencemore » of palpable disease, and PSA level to further define subgroups benefitting from ADT. Results: Median follow-up was 5 years; 420 patients received ADT + dose-escalated RT, and 624 received dose-escalated RT alone. For all patients, no advantages in any clinical endpoints at 8 years were associated with ADT administration. No differences in any endpoints were associated with ADT administration based on intermediate- vs. high-risk group or RT modality when analyzed separately. Patients with palpable disease plus Gleason {>=}8 demonstrated improved clinical failure rates and a trend toward improved survival with ADT. Intermediate-risk patients treated with brachytherapy alone had improved biochemical control when ADT was given. Conclusion: Benefits of ADT in the setting of dose-escalated RT remain poorly defined. This question must continue to be addressed in prospective study.« less

  9. Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields.

    PubMed

    Lonski, P; Keehan, S; Siva, S; Pham, D; Franich, R D; Taylor, M L; Kron, T

    2017-05-01

    To assess out-of-field dose using three different variants of LiF thermoluminescence dosimeters (TLD) for ten patients who underwent stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) and compare with treatment planning system (TPS) dose calculations. Thermoluminescent dosimeter (TLD) measurements were conducted at 20, 30, 40 and 50cm from isocentre on ten patients undergoing SABR for primary RCC. Three types of high-sensitivity LiF:Mg,Cu,P TLD material with different 6 Li/ 7 Li isotope ratios were used. Patient plans were calculated using Eclipse Anisotropic Analytical Algorithm (AAA) for clinical evaluation and recalculated using Pencil Beam Convolution (PBC) algorithm for comparison. Both AAA and PBC showed diminished accuracy for photon doses at increasing distance out-of-field. At 50cm, measured photon dose was 0.3cGy normalised to a 10Gy prescription on average with only small variation across all patients. This is likely due to the leakage component of the out-of-field dose. The 6 Li-enriched TLD materials showed increased signal attributable to additional neutron contribution. LiF:Mg,Cu,P TLD containing 6 Li is sensitive enough to measure out-of-field dose 50cm from isocentre however will over-estimate the photon component of out-of-field dose in high energy treatments due to the presence of thermal neutrons. 7 Li enriched materials which are insensitive to neutrons are therefore required for accurate photon dosimetry. Neutron signal has been shown here to increase with MUs and is higher for patients treated using certain non coplanar beam arrangements. Further work is required to convert this additional neutron signal to dose. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Response of murine tumours to combinations of CCNU with misonidazole and other radiation sensitizers.

    PubMed Central

    Siemann, D. W.

    1982-01-01

    The effect of combinations of the conventional chemotherapeutic agent 1-(2-chloroethyl)-3-cyclohexyl-1-nitrosourea (CCNU) and nitroimidazole radiation sensitizers was evaluated in female C3H mice. Tumour response to single-agent or combination therapy was assessed in a tumour growth-delay assay. In the KHT sarcoma the simultaneous addition of misonidazole (MISO) was found to increase significantly the tumour growth delay resulting from CCNU treatment. The observed enhancement ratios (ER) increased with MISO dose, and ranged from 1.3 to 1.9 for sensitizer doses of 0.25-1.0 mg/g. The combination of CCNU and 1.0 or 0.5 mg/g MISO in the RIF-1 tumour or the MT-1 tumour produced ERs of approximately 2.0 and approximately 1.5 respectively. In the KHT sarcoma a series of other nitroimidazole sensitizers, including Ro-05-9963, SR-2555, SR-2508 and metronidazole (METRO), were also evaluated at equimolar doses (5 mmol/kg) in combination with a 20mg/kg dose of CCNU. Unlike MISO, these compounds in general failed to enhance the CCNU cytotoxicity in this tumour model. However, SR-2508 did enhance the response of the RIF-1 tumour to large single doses of CCNU, though not as much as MISO. Normal-tissue toxicity was determined using peripheral white blood cell (WBC) counts 3 days after treatment. CCNU doses of 10-50 mg/kg given either alone or in simultaneous combination with 0.5 or 1.0 mg/g MISO were studied. WBC toxicity increased with CCNU dose, but the addition of MISO at either dose did not significantly enhance this normal-tissue toxicity. PMID:6460517

  11. Toxicogenomic profiling in maternal and fetal rodent brains following gestational exposure to chlorpyrifos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreira, Estefania G.; Department of Physiological Sciences, State University of Londrina, Londrina, PR; Yu Xiaozhong

    2010-06-15

    Considering the wide variety of effects that have been reported to occur in the developmental neurotoxicity of chlorpyrifos (CP) and the lack of consensus on their dependence of brain acetylcholinesterase (AChE) activity inhibition, we applied microarray technology to explore dose-dependent alterations in transcriptional response in the fetal and maternal C57BL/6 mouse brain after daily gestational exposure (days 6 to 17) to CP (2, 4, 10, 12 or 15 mg/kg, sc). We identified significantly altered genes across doses and assessed for overrepresentation of Gene Ontology (GO) biological processes and KEGG pathways. We further clustered genes based on their expression profiles acrossmore » doses and repeated the GO/pathways analysis for each cluster. The dose-effect relationship of CP on gene expression, both at the gene and pathway levels was non-monotonic and not necessarily related to brain AChE inhibition. The largest impact was observed in the 10 mg/kg dose group which was also the LOAEL for brain AChE inhibition. In the maternal brain, lower doses (4 mg/kg) influenced GO categories and pathways such as cell adhesion, behavior, lipid metabolism, long-term potentiation, nervous system development, neurogenesis, synaptic transmission. In the fetal brain, lower doses (2 and/or 4 mg/kg) significantly altered cell division, translation, transmission of nerve impulse, chromatin modification, long-term potentiation. In addition, some genes involved in nervous system development and signaling were shown to be specifically influenced by these lower CP doses. Our approach was sensitive and reflected the diversity of responses known to be disrupted by CP and highlighted possible additional consequences of CP neurotoxicity, such as disturbance of the ubiquitin proteasome system.« less

  12. Future directions for LDEF ionizing radiation modeling and assessments

    NASA Technical Reports Server (NTRS)

    Armstrong, T. W.; Colborn, B. L.

    1993-01-01

    A calculational program utilizing data from radiation dosimetry measurements aboard the Long Duration Exposure Facility (LDEF) satellite to reduce the uncertainties in current models defining the ionizing radiation environment is in progress. Most of the effort to date has been on using LDEF radiation dose measurements to evaluate models defining the geomagnetically trapped radiation, which has provided results applicable to radiation design assessments being performed for Space Station Freedom. Plans for future data comparisons, model evaluations, and assessments using additional LDEF data sets (LET spectra, induced radioactivity, and particle spectra) are discussed.

  13. Dose addition models based on biologically-relevant reductions in fetal testosterone accurately predict postnatal reproductive tract alterations by a phthalate mixture in rats

    EPA Science Inventory

    Challenges in cumulative risk assessment of anti-androgenic phthalate mixtures include a lack of data on all the individual phthalates and difficulty determining the biological relevance of reduction in fetal testosterone (T) on postnatal development. The objectives of the curren...

  14. Assessment of neutron dosemeters around standard sources and nuclear fissile objects.

    PubMed

    Raimondi, N; Tournier, B; Groetz, J E; Piot, J; Riebler, E; Crovisier, P; Chambaudet, A; Cabanné, N

    2002-01-01

    In order to evaluate the neutron doses around nuclear fissile objects, a comparative study has been made on several neutron dosemeters: bubble dosemeters, etched-track detectors (CR-39) and 3He-filled proportional counters used as dose-rate meters. The measurements were made on the ambient and the personal dose equivalents H*(10) and Hp(10). Results showed that several bubble dosemeters should have been used due to a low reproducibility in the measurements. A strong correlation with the neutron energy was also found, with about a 30% underestimation of Hp(10) for neutrons from the PuBe source, and about a 9% overestimation for neutrons from the 252Cf source. Measurements of the nuclear fissile objects were made using the CR-39 and the dose-rate meters. The CR-39 led to an underestimation of 30% with respect to the neutron dose-rate meter measurements. In addition, the MCNP calculation code was used in the different configurations.

  15. A Four-Step and Four-Criteria Approach for Evaluating Evidence of Dose Addition in Chemical Mixture Toxicity

    EPA Science Inventory

    Dose addition is the most frequently-used component-based approach for predicting dose response for a mixture of toxicologically-similar chemicals and for statistical evaluation of whether the mixture response is consistent with dose additivity and therefore predictable from the ...

  16. Curcumin inhibits cancer stem cell phenotypes in ex vivo models of colorectal liver metastases, and is clinically safe and tolerable in combination with FOLFOX chemotherapy

    PubMed Central

    James, Mark I.; Iwuji, Chinenye; Irving, Glen; Karmokar, Ankur; Higgins, Jennifer A.; Griffin-Teal, Nicola; Thomas, Anne; Greaves, Peter; Cai, Hong; Patel, Samita R.; Morgan, Bruno; Dennison, Ashley; Metcalfe, Matthew; Garcea, Giuseppe; Lloyd, David M.; Berry, David P.; Steward, William P.; Howells, Lynne M.; Brown, Karen

    2015-01-01

    In vitro and pre-clinical studies have suggested that addition of the diet-derived agent curcumin may provide a suitable adjunct to enhance efficacy of chemotherapy in models of colorectal cancer. However, the majority of evidence for this currently derives from established cell lines. Here, we utilised patient-derived colorectal liver metastases (CRLM) to assess whether curcumin may provide added benefit over 5-fluorouracil (5-FU) and oxaliplatin (FOLFOX) in cancer stem cell (CSC) models. Combination of curcumin with FOLFOX chemotherapy was then assessed clinically in a phase I dose escalation study. Curcumin alone and in combination significantly reduced spheroid number in CRLM CSC models, and decreased the number of cells with high aldehyde dehydrogenase activity (ALDHhigh/CD133−). Addition of curcumin to oxaliplatin/5-FU enhanced anti-proliferative and pro-apoptotic effects in a proportion of patient-derived explants, whilst reducing expression of stem cell-associated markers ALDH and CD133. The phase I dose escalation study revealed curcumin to be a safe and tolerable adjunct to FOLFOX chemotherapy in patients with CRLM (n = 12) at doses up to 2 grams daily. Curcumin may provide added benefit in subsets of patients when administered with FOLFOX, and is a well-tolerated chemotherapy adjunct. PMID:25979230

  17. Neutron irradiation and damage assessment of plastic scintillators of the Tile Calorimeter

    NASA Astrophysics Data System (ADS)

    Mdhluli, J. E.; Mellado, B.; Sideras-Haddad, E.

    2017-01-01

    Following the comparative study of proton induced radiation damage on various plastic scintillator samples from the ATLAS-CERN detector, a study on neutron irradiation and damage assessment on the same type of samples will be conducted. The samples will be irradiated with different dose rates of neutrons produced in favourable nuclear reactions using a radiofrequency linear particle accelerator as well as from the SAFARI nuclear reactor at NECSA. The MCNP 5 code will be utilized in simulating the neutron transport for determining the dose rate. Light transmission and light yield tests will be performed in order to assess the radiation damage on the scintillators. In addition, Raman spectroscopy and Electron Paramagnetic Resonance (EPR) analysis will be used to characterize the samples after irradiation. The project aims to extent these studies to include radiation assessment damage of any component that processes the scintillating light and deteriorates the quantum efficiency of the Tilecal detector, namely, photomultiplier tubes, wavelength shifting optical fibres and the readout electronics. They will also be exposed to neutron irradiation and the damage assessed in the same manner.

  18. Comparison of the Efficacy and Safety of Oritavancin Front-Loaded Dosing Regimens to Daily Dosing: an Analysis of the SIMPLIFI Trial ▿

    PubMed Central

    Dunbar, Lala M.; Milata, Joe; McClure, Ty; Wasilewski, Margaret M.

    2011-01-01

    Oritavancin is a novel lipoglycopeptide with demonstrated effectiveness against complicated skin and skin structure infections (cSSSI) caused by Gram-positive pathogens, including those caused by methicillin-resistant Staphylococcus aureus (MRSA). The pharmacokinetic and pharmacodynamic profile of oritavancin is favorable for single or infrequent dosing. A phase 2, multicenter, randomized, double-blind, parallel, active-comparator study (ClinicalTrials.gov identifier, NCT00514527) of single and infrequent dosing of intravenous (i.v.) oritavancin for the treatment of cSSSI caused by Gram-positive pathogens (wound infections, major abscess, and cellulitis) was undertaken to evaluate the noninferiority of front-loaded dosing regimens compared to a daily-dosing regimen. A total of 302 patients ≥18 years of age were randomized equally to one of three oritavancin treatment groups, receiving either a daily dose (200 mg) administered for 3 to 7 days, a single dose (1,200 mg), or an infrequent dose (800-mg dose, with the option for an additional 400 mg on day 5). The primary efficacy was defined as a clinical response in clinically evaluable (CE) patients assessed at days 21 to 29 (test of cure [TOC]). The cure rates in the CE population were 72.4% (55/76) in the daily-dose group, 81.5% (66/81) in the 1,200-mg-single-dose group, and 77.5% (55/71) in the infrequent-dose group. In patients with MRSA at baseline, the cure rates were 78.3% (18/23), 73.0% (27/37), and 87.0% (20/23) in the daily-, 1,200-mg-single-, and infrequent-dose groups, respectively; however, the study was not powered to assess outcomes in the MRSA subpopulation, and given the heterogeneity of the types of infection and the small sample size, these do not suggest any true differences in efficacy rates for these pathogens. The frequencies of adverse events were similar among treatment groups. The results of this study show that single- and infrequent-dosing schedules of oritavancin were as efficacious as daily administration and had a similar safety profile in treating cSSSI caused by Gram-positive pathogens, including MRSA. PMID:21537018

  19. Mathematical modelling and quantitative methods.

    PubMed

    Edler, L; Poirier, K; Dourson, M; Kleiner, J; Mileson, B; Nordmann, H; Renwick, A; Slob, W; Walton, K; Würtzen, G

    2002-01-01

    The present review reports on the mathematical methods and statistical techniques presently available for hazard characterisation. The state of the art of mathematical modelling and quantitative methods used currently for regulatory decision-making in Europe and additional potential methods for risk assessment of chemicals in food and diet are described. Existing practices of JECFA, FDA, EPA, etc., are examined for their similarities and differences. A framework is established for the development of new and improved quantitative methodologies. Areas for refinement, improvement and increase of efficiency of each method are identified in a gap analysis. Based on this critical evaluation, needs for future research are defined. It is concluded from our work that mathematical modelling of the dose-response relationship would improve the risk assessment process. An adequate characterisation of the dose-response relationship by mathematical modelling clearly requires the use of a sufficient number of dose groups to achieve a range of different response levels. This need not necessarily lead to an increase in the total number of animals in the study if an appropriate design is used. Chemical-specific data relating to the mode or mechanism of action and/or the toxicokinetics of the chemical should be used for dose-response characterisation whenever possible. It is concluded that a single method of hazard characterisation would not be suitable for all kinds of risk assessments, and that a range of different approaches is necessary so that the method used is the most appropriate for the data available and for the risk characterisation issue. Future refinements to dose-response characterisation should incorporate more clearly the extent of uncertainty and variability in the resulting output.

  20. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.

    PubMed

    Mathieu, Kelsey B; Ai, Hua; Fox, Patricia S; Godoy, Myrna Cobos Barco; Munden, Reginald F; de Groot, Patricia M; Pan, Tinsu

    2014-03-06

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground-glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back-projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast-to-noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening.

  1. Phase I study of continuous MKC-1 in patients with advanced or metastatic solid malignancies using the modified Time-to-Event Continual Reassessment Method (TITE-CRM) dose escalation design.

    PubMed

    Tevaarwerk, Amye; Wilding, George; Eickhoff, Jens; Chappell, Rick; Sidor, Carolyn; Arnott, Jamie; Bailey, Howard; Schelman, William; Liu, Glenn

    2012-06-01

    MKC-1 is an oral cell-cycle inhibitor with broad antitumor activity in preclinical models. Clinical studies demonstrated modest antitumor activity using intermittent dosing schedule, however additional preclinical data suggested continuous dosing could be efficacious with additional effects against the mTor/AKT pathway. The primary objectives were to determine the maximum tolerated dose (MTD) and response of continuous MKC-1. Secondary objectives included characterizing the dose limiting toxicities (DLTs) and pharmacokinetics (PK). Patients with solid malignancies were eligible, if they had measurable disease, ECOG PS ≤1, and adequate organ function. Exclusions included brain metastases and inability to receive oral drug. MKC-1 was dosed twice daily, continuously in 28-day cycles. Other medications were eliminated if there were possible drug interactions. Doses were assigned using a TITE-CRM algorithm following enrollment of the first 3 pts. Disease response was assessed every 8 weeks. Between 5/08-9/09, 24 patients enrolled (15 M/9 F, median 58 years, range 44-77). Patients 1-3 received 120 mg/d of MKC-1; patients 4-24 were dosed per the TITE-CRM algorithm: 150 mg [n = 1], 180 [2], 200 [1], 230 [1], 260 [5], 290 [6], 320 [5]. The median time on drug was 8 weeks (range 4-28). The only DLT occurred at 320 mg (grade 3 fatigue). Stable disease occurred at 150 mg/d (28 weeks; RCC) and 320 mg/d (16 weeks; breast, parotid). Escalation halted at 320 mg/d. Day 28 pharmacokinetics indicated absorption and active metabolites. Continuous MKC-1 was well-tolerated; there were no RECIST responses, although clinical benefit occurred in 3/24 pts. Dose escalation stopped at 320 mg/d, and this is the MTD as defined by the CRM dose escalation algorithm; this cumulative dose/cycle exceeds that determined from intermittent dosing studies. A TITE-CRM allowed for rapid dose escalation and was able to account for late toxicities with continuous dosing via a modified algorithm.

  2. Lifetime Effective Dose Assessment Based on Background Outdoor Gamma Exposure in Chihuahua City, Mexico

    PubMed Central

    Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia

    2015-01-01

    Determining ionizing radiation in a geographic area serves to assess its effects on a population’s health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h−1. At the same sites, 48 soil samples were taken to obtain the activity concentrations of 226Ra, 232Th and 40K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h−1. Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg−1, for 226Ra, 232Th and 40K, respectively. From the analysis, the spatial distribution of 232Th, 226Ra and 40K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize. PMID:26437425

  3. Reducing Xerostomia After Chemo-IMRT for Head and Neck Cancer: Beyond Sparing the Parotid Glands

    PubMed Central

    Little, Michael; Schipper, Matthew; Feng, Felix Y.; Vineberg, Karen; Cornwall, Craig; Murdoch-Kinch, Carol-Anne; Eisbruch, Avraham

    2011-01-01

    Purpose To assess whether in addition to sparing parotid glands (PGs), xerostomia after chemo-IMRT of head and neck cancer is affected by reducing doses to other salivary glands. Methods Prospective study: 78 patients with stages III/IV oropharynx/nasopharynx cancers received chemo-IMRT aiming to spare the parts outside the targets of bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) (when contralateral level I was not a target). Pretherapy and periodically through 24 months, validated patient-reported xerostomia questionnaires (XQ) scores and observer-graded xerostomia were recorded, and stimulated and unstimulated saliva measured selectively from each of the PGs and SMGs. Mean OC doses served as surrogates of minor salivary glands dysfunction. Regression models assessed XQ and observer-graded xerostomia predictors. Results Statistically significant predictors of the XQ score in univariate analysis included OC, PG, and SMG mean doses, as well as baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. OC, PG and SMG mean doses were moderately inter-correlated (r=0.47–0.55). In multivariate analyses, after adjusting for PG and SMG doses, OC mean dose (p < 0.0001), time from RT (p < 0.0001), and stimulated PG saliva (p < 0.0025) were significant predictors for XQ scores, and OC mean dose and time for observer-graded xerostomia. While scatter plots showed no thresholds, OC mean doses <40 Gy and contralateral SMG mean <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy time points. Conclusion PG, SMG and OC mean doses were significant predictors of both patient-reported and observer-rated xerostomia after chemo-IMRT, with OC doses remaining significant after adjusting for PG and SMG doses. These results support efforts to spare all salivary glands by IMRT, beyond the PGs alone. PMID:22056067

  4. Lifetime Effective Dose Assessment Based on Background Outdoor Gamma Exposure in Chihuahua City, Mexico.

    PubMed

    Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia

    2015-09-30

    Determining ionizing radiation in a geographic area serves to assess its effects on a population's health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h(-1). At the same sites, 48 soil samples were taken to obtain the activity concentrations of (226)Ra, (232)Th and (40)K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h(-1). Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg(-1), for (226)Ra, (232)Th and (40)K, respectively. From the analysis, the spatial distribution of (232)Th, (226)Ra and (40)K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize.

  5. Avelumab for metastatic or locally advanced previously treated solid tumours (JAVELIN Solid Tumor): a phase 1a, multicohort, dose-escalation trial.

    PubMed

    Heery, Christopher R; O'Sullivan-Coyne, Geraldine; Madan, Ravi A; Cordes, Lisa; Rajan, Arun; Rauckhorst, Myrna; Lamping, Elizabeth; Oyelakin, Israel; Marté, Jennifer L; Lepone, Lauren M; Donahue, Renee N; Grenga, Italia; Cuillerot, Jean-Marie; Neuteboom, Berend; Heydebreck, Anja von; Chin, Kevin; Schlom, Jeffrey; Gulley, James L

    2017-05-01

    Avelumab (MSB0010718C) is a human IgG1 monoclonal antibody that binds to PD-L1, inhibiting its binding to PD-1, which inactivates T cells. We aimed to establish the safety and pharmacokinetics of avelumab in patients with solid tumours while assessing biological correlatives for future development. This open-label, single-centre, phase 1a, dose-escalation trial (part of the JAVELIN Solid Tumor trial) assessed four doses of avelumab (1 mg/kg, 3 mg/kg, 10 mg/kg, and 20 mg/kg), with dose-level cohort expansions to provide additional safety, pharmacokinetics, and target occupancy data. This study used a standard 3 + 3 cohort design and assigned patients sequentially at trial entry according to the 3 + 3 dose-escalation algorithm and depending on the number of dose-limiting toxicities during the first 3-week assessment period (the primary endpoint). Patient eligibility criteria included age 18 years or older, Eastern Cooperative Oncology Group performance status 0-1, metastatic or locally advanced previously treated solid tumours, and adequate end-organ function. Avelumab was given as a 1-h intravenous infusion every 2 weeks. Patients in the dose-limiting toxicity analysis set were assessed for the primary endpoint of dose-limiting toxicity, and all patients enrolled in the dose-escalation part were assessed for the secondary endpoints of safety (treatment-emergent and treatment-related adverse events according to National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0), pharmacokinetic and pharmacodynamic profiles (immunological effects), best overall response by Response Evaluation Criteria, and antidrug antibody formation. The population for the pharmacokinetic analysis included a subset of patients with rich pharmacokinetic samples from two selected disease-specific expansion cohorts at the same study site who had serum samples obtained at multiple early timepoints. This trial is registered with ClinicalTrials.gov, number NCT01772004. Patient recruitment to the dose-escalation part reported here is closed. Between Jan 31, 2013, and Oct 8, 2014, 53 patients were enrolled (four patients at 1 mg/kg, 13 at 3 mg/kg, 15 at 10 mg/kg, and 21 at 20 mg/kg). 18 patients were analysed in the dose-limiting toxicity analysis set: three at dose level 1 (1 mg/kg), three at dose level 2 (3 mg/kg), six at dose level 3 (10 mg/kg), and six at dose level 4 (20 mg/kg). Only one dose-limiting toxicity occurred, at the 20 mg/kg dose, and thus the maximum tolerated dose was not reached. In all 53 enrolled patients (the safety analysis set), common treatment-related adverse events (occurring in >10% of patients) included fatigue (21 patients [40%]), influenza-like symptoms (11 [21%]), fever (8 [15%]), and chills (6 [11%]). Grade 3-4 treatment-related adverse events occurred in nine (17%) of 53 patients, with autoimmune disorder (n=3), increased blood creatine phosphokinase (n=2), and increased aspartate aminotransferase (n=2) each occurring in more than one patient (autoimmune disorder in two patients at 10 mg/kg and one patient at 20 mg/kg, increased blood creatine phosphokinase in two patients at 20 mg/kg, and increased aspartate aminotransferase in one patient at 1 mg/kg, and one patient at 10 mg/kg). Six (11%) of 53 patients had a serious treatment-related adverse event: autoimmune disorder (two [13%]), lower abdominal pain (one [7%]), fatigue (one [7%]), and influenza-like illness (one [7%]) in three patients treated at 10 mg/kg dose level, and autoimmune disorder (one [5%]), increased amylase (one [5%]), myositis (one [5%]), and dysphonia (one [5%]) in three patients who received the 20 mg/kg dose. We recorded some evidence of clinical activity in various solid tumours, with partial confirmed or unconfirmed responses in four (8%) of 53 patients; 30 (57%) additional patients had stable disease. Pharmacokinetic analysis (n=86) showed a dose-proportional exposure between doses of 3 mg/kg and 20 mg/kg and a half-life of 95-99 h (3·9-4·1 days) at the 10 mg/kg and 20 mg/kg doses. Target occupancy was greater than 90% at doses of 3 mg/kg and 10 mg/kg. Antidrug antibodies were detected in two (4%) of 53 patients. No substantial differences were found in absolute lymphocyte count or multiple immune cell subsets, including those expressing PD-L1, after treatment with avelumab. 31 (58%) of 53 patients in the overall safety population died; no deaths were related to treatment on study. Avelumab has an acceptable toxicity profile up to 20 mg/kg and the maximum tolerated dose was not reached. Based on pharmacokinetics, target occupancy, and immunological analysis, we chose 10 mg/kg every 2 weeks as the dose for further development and phase 3 trials are ongoing. National Cancer Institute and Merck KGaA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Assessing human health response in life cycle assessment using ED10s and DALYs: part 2--Noncancer effects.

    PubMed

    Pennington, David; Crettaz, Pierre; Tauxe, Annick; Rhomberg, Lorenz; Brand, Kevin; Jolliet, Olivier

    2002-10-01

    In Part 1 of this article we developed an approach for the calculation of cancer effect measures for life cycle assessment (LCA). In this article, we propose and evaluate the method for the screening of noncancer toxicological health effects. This approach draws on the noncancer health risk assessment concept of benchmark dose, while noting important differences with regulatory applications in the objectives of an LCA study. We adopt the centraltendency estimate of the toxicological effect dose inducing a 10% response over background, ED10, to provide a consistent point of departure for default linear low-dose response estimates (betaED10). This explicit estimation of low-dose risks, while necessary in LCA, is in marked contrast to many traditional procedures for noncancer assessments. For pragmatic reasons, mechanistic thresholds and nonlinear low-dose response curves were not implemented in the presented framework. In essence, for the comparative needs of LCA, we propose that one initially screens alternative activities or products on the degree to which the associated chemical emissions erode their margins of exposure, which may or may not be manifested as increases in disease incidence. We illustrate the method here by deriving the betaED10 slope factors from bioassay data for 12 chemicals and outline some of the possibilities for extrapolation from other more readily available measures, such as the no observable adverse effect levels (NOAEL), avoiding uncertainty factors that lead to inconsistent degrees of conservatism from chemical to chemical. These extrapolations facilitated the initial calculation of slope factors for an additional 403 compounds; ranging from 10(-6) to 10(3) (risk per mg/kg-day dose). The potential consequences of the effects are taken into account in a preliminary approach by combining the betaED10 with the severity measure disability adjusted life years (DALY), providing a screening-level estimate of the potential consequences associated with exposures, integrated over time and space, to a given mass of chemical released into the environment for use in LCA.

  7. TRIAGE DOSE ASSESSMENT FOR PARTIAL-BODY EXPOSURE: DICENTRIC ANALYSIS

    PubMed Central

    Moroni, Maria; Pellmar, Terry C.

    2009-01-01

    Partial-body biodosimetry is likely to be required after a radiological or nuclear exposure. Clinical signs and symptoms, distribution of dicentrics in circulating blood cells, organ-specific biomarkers, physical signals in teeth and nails all can provide indications of non-homogeneous exposures. Organ specific biomarkers may provide early warning regarding physiological systems at risk after radiation injury. Use of a combination of markers and symptoms will be needed for clinical insights for therapeutic approaches. Analysis of dicentrics, a marker specific for radiation injury, is the “Gold standard” of biodosimetry and can reveal partial-body exposures. Automation of sample processing for dicentric analysis can increase throughput with customization of off-the-shelf technologies for cytogenetic sample processing and information management. Automated analysis of the metaphase spreads is currently limited but improvements are in development. Our efforts bridge the technological gaps to allow the use of dicentric chromosome assay (DCA) for risk-based stratification of mass casualties. This article summarizes current knowledge on partial-body cytogenetic dose assessment synthesizing information leading to the proposal of an approach to triage dose prediction in radiation mass casualties, based on equivalent whole-body doses under partial-body exposure conditions and assesses the validity of using this model. An initial screening using only 20 metaphase spreads per subject can confirm irradiation above 2-Gy. A subsequent increase to 50 metaphases improves dose determination to allow risk stratification for clinical triage. Metaphases evaluated for inhomogeneous distribution of dicentrics can reveal partial-body exposures. We tested the validity of this approach in an in vitro model that simulates partial-body irradiation by mixing irradiated and un-irradiated lymphocytes in various proportions. Our preliminary results support the notion that this approach will be effective under a range of conditions including some partial-body exposures, but may have limitations with low doses or small proportions of irradiated body. Our studies address an important problem in the diagnosis of partial-body irradiation and dose assessment in mass casualties and propose a solution. However, additional work is needed to fully develop and validate the application of DCA to partial-body exposures. PMID:20065689

  8. Hierarchical dose response of E. coli O157:H7 from human outbreaks incorporating heterogeneity in exposure.

    PubMed

    Teunis, P F M; Ogden, I D; Strachan, N J C

    2008-06-01

    The infectivity of pathogenic microorganisms is a key factor in the transmission of an infectious disease in a susceptible population. Microbial infectivity is generally estimated from dose-response studies in human volunteers. This can only be done with mildly pathogenic organisms. Here a hierarchical Beta-Poisson dose-response model is developed utilizing data from human outbreaks. On the lowest level each outbreak is modelled separately and these are then combined at a second level to produce a group dose-response relation. The distribution of foodborne pathogens often shows strong heterogeneity and this is incorporated by introducing an additional parameter to the dose-response model, accounting for the degree of overdispersion relative to Poisson distribution. It was found that heterogeneity considerably influences the shape of the dose-response relationship and increases uncertainty in predicted risk. This uncertainty is greater than previously reported surrogate and outbreak models using a single level of analysis. Monte Carlo parameter samples (alpha, beta of the Beta-Poisson model) can be readily incorporated in risk assessment models built using tools such as S-plus and @ Risk.

  9. Comparison of selected dose calculation algorithms in radiotherapy treatment planning for tissues with inhomogeneities

    NASA Astrophysics Data System (ADS)

    Woon, Y. L.; Heng, S. P.; Wong, J. H. D.; Ung, N. M.

    2016-03-01

    Inhomogeneity correction is recommended for accurate dose calculation in radiotherapy treatment planning since human body are highly inhomogeneous with the presence of bones and air cavities. However, each dose calculation algorithm has its own limitations. This study is to assess the accuracy of five algorithms that are currently implemented for treatment planning, including pencil beam convolution (PBC), superposition (SP), anisotropic analytical algorithm (AAA), Monte Carlo (MC) and Acuros XB (AXB). The calculated dose was compared with the measured dose using radiochromic film (Gafchromic EBT2) in inhomogeneous phantoms. In addition, the dosimetric impact of different algorithms on intensity modulated radiotherapy (IMRT) was studied for head and neck region. MC had the best agreement with the measured percentage depth dose (PDD) within the inhomogeneous region. This was followed by AXB, AAA, SP and PBC. For IMRT planning, MC algorithm is recommended for treatment planning in preference to PBC and SP. The MC and AXB algorithms were found to have better accuracy in terms of inhomogeneity correction and should be used for tumour volume within the proximity of inhomogeneous structures.

  10. Pharmacodynamic and pharmacokinetic effects of the intravenous CB1 receptor agonist Org 26828 in healthy male volunteers.

    PubMed

    Zuurman, Lineke; Passier, Paul C C M; de Kam, Marieke L; Kleijn, Huub J; Cohen, Adam F; van Gerven, Joop M A

    2010-11-01

    An ideal drug for outpatient treatments under conscious sedation would have both sedative and analgesic properties. CB1/CB2 agonists are expected to have sedative, amnestic, analgesic and anti-emetic properties. The main objective of this first study in humans was to assess the sedative properties of intravenous Org 26828. In addition, pharmacokinetics, amnestic properties, postural stability, and behavioural and cardiovascular effects were studied. Midazolam intravenous 0.1 mg/kg and placebo were used as controls. The pharmacokinetic parameters (Cmax and AUC0-inf) of the main metabolite Org 26761 were proportional to dose. No effects were observed after doses up to 0.3 μg/kg of Org 26828. Dose-related effects were observed at higher doses. Although subjects reported subjective sedation after administration of Org 26828 at 3 and 6 μg/kg, the observed sedation was considerably less than after midazolam. Doses higher than the maximum tolerated dose of 1 μg/kg of Org 26828 caused unpleasant central nervous system effects (anxiety, paranoia, hallucinations). Therefore, Org 26828 is not suitable for providing sedation for outpatient surgical procedures.

  11. Assessments of Voice Use and Voice Quality among College/University Singing Students Ages 18–24 through Ambulatory Monitoring with a Full Accelerometer Signal

    PubMed Central

    Schloneger, Matthew; Hunter, Eric

    2016-01-01

    The multiple social and performance demands placed on college/university singers could put their still developing voices at risk. Previous ambulatory monitoring studies have analyzed the duration, intensity, and frequency (in Hz) of voice use among such students. Nevertheless, no studies to date have incorporated the simultaneous acoustic voice quality measures into the acquisition of these measures to allow for direct comparison during the same voicing period. Such data could provide greater insight into how young singers use their voices, as well as identify potential correlations between vocal dose and acoustic changes in voice quality. The purpose of this study was to assess the voice use and estimated voice quality of college/university singing students (18–24 y/o, N = 19). Ambulatory monitoring was conducted over three full, consecutive weekdays measuring voice from an unprocessed accelerometer signal measured at the neck. From this signal were analyzed traditional vocal dose metrics such as phonation percentage, dose time, cycle dose, and distance dose. Additional acoustic measures included perceived pitch, pitch strength, LTAS slope, alpha ratio, dB SPL 1–3 kHz, and harmonic-to-noise ratio. Major findings from more than 800 hours of recording indicated that among these students (a) higher vocal doses correlated significantly with greater voice intensity, more vocal clarity and less perturbation; and (b) there were significant differences in some acoustic voice quality metrics between non-singing, solo singing and choral singing. PMID:26897545

  12. On the behavioural specificity of hypophagia induced in male rats by mCPP, naltrexone, and their combination.

    PubMed

    Wright, F L; Rodgers, R J

    2014-02-01

    Serotonergic (5-hydroxytryptamine, 5-HT) and opioidergic mechanisms are intimately involved in appetite regulation. In view of recent evidence of positive anorectic interactions between opioid and various non-opioid substrates, our aim was to assess the behavioural specificity of anorectic responses to the opioid receptor antagonist naltrexone, the 5-HT2C/1B receptor agonist mCPP and their combination. Behavioural profiling techniques, including the behavioural satiety sequence (BSS), were used to examine acute drug effects in non-deprived male rats tested with palatable mash. Experiment 1 characterised the dose-response profile of mCPP (0.1-3.0 mg/kg), while experiment 2 assessed the effects of combined treatment with a sub-anorectic dose of mCPP (0.1 mg/kg) and one of two low doses of naltrexone (0.1 and 1.0 mg/kg). Experiment 1 confirmed the dose-dependent anorectic efficacy of mCPP, with robust effects on intake and feeding-related measures observed at 3.0 mg/kg. However, that dose was also associated with other behavioural alterations including increased grooming, reductions in locomotion and sniffing, and disruption of the BSS. In experiment 2, naltrexone dose-dependently reduced food intake and time spent feeding, effects accompanied by a behaviourally selective acceleration in the BSS. However, the addition of 0.1 mg/kg mCPP did not significantly alter the behavioural changes observed in response to either dose of naltrexone given alone. In contrast to recently reported positive anorectic interactions involving low-dose combinations of opioid receptor antagonists or mCPP with cannabinoid CB1 receptor antagonists, present results would not appear to provide any support for potentially clinically relevant anorectic interactions between opioid and 5-HT2C/1B receptor mechanisms.

  13. Immunogenicity of HPV prophylactic vaccines: Serology assays and their use in HPV vaccine evaluation and development.

    PubMed

    Pinto, Ligia A; Dillner, Joakim; Beddows, Simon; Unger, Elizabeth R

    2018-01-17

    When administered as standard three-dose schedules, the licensed HPV prophylactic vaccines have demonstrated extraordinary immunogenicity and efficacy. We summarize the immunogenicity of these licensed vaccines and the most commonly used serology assays, with a focus on key considerations for one-dose vaccine schedules. Although immune correlates of protection against infection are not entirely clear, both preclinical and clinical evidence point to neutralizing antibodies as the principal mechanism of protection. Thus, immunogenicity assessments in vaccine trials have focused on measurements of antibody responses to the vaccine. Non-inferiority of antibody responses after two doses of HPV vaccines separated by 6 months has been demonstrated and this evidence supported the recent WHO recommendations for two-dose vaccination schedules in both boys and girls 9-14 years of age. There is also some evidence suggesting that one dose of HPV vaccines may provide protection similar to the currently recommended two-dose regimens but robust data on efficacy and immunogenicity of one-dose vaccine schedules are lacking. In addition, immunogenicity has been assessed and reported using different methods, precluding direct comparison of results between different studies and vaccines. New head-to-head vaccine trials evaluating one-dose immunogenicity and efficacy have been initiated and an increase in the number of trials relying on immunobridging is anticipated. Therefore, standardized measurement and reporting of immunogenicity for the up to nine HPV types targeted by the current vaccines is now critical. Building on previous HPV serology assay standardization and harmonization efforts initiated by the WHO HPV LabNet in 2006, new secondary standards, critical reference reagents and testing guidelines will be generated as part of a new partnership to facilitate harmonization of the immunogenicity testing in new HPV vaccine trials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Satiety effects of a whole-grain fibre composite ingredient: reduced food intake and appetite ratings.

    PubMed

    Harrold, Joanne; Breslin, Leanne; Walsh, Jennifer; Halford, Jason; Pelkman, Christine

    2014-10-01

    The current study assesses the impact on appetite and food intake of a novel co-processed ingredient containing a viscous fibre and whole-grain high-amylose corn flour, a source of type 1 and type 2 resistant starch (HAM-RS). Ninety adults completed a crossover, placebo-controlled study comparing two doses of the ingredient (20 and 30 g) to a maltodextrin control in a fruit-based smoothie served with breakfast. Ad libitum food intake was measured over the day and visual analogue scales were used to assess subjective appetite sensations. Subjects consumed 7% less energy intake at dinner following the 30 g dose (p = 0.02) compared to control. In addition, a trend for lower lunch intake (5% less weight of food) was observed for the 20 g dose (p = 0.10). Reductions were also observed for the two meals combined, with 3% lower energy intake for the 20 g dose (p = 0.04) and 5% less weight of food consumed for the 30 g dose (p = 0.04). Lower ratings of hunger were reported at 3 h after breakfast for both doses and also at 2 and 3 h after lunch for the 30 g dose. With ratings combined to compute an overall appetite score, a trend for lower appetite scores at 3 h after breakfast was found for both doses. Consistent with this, significant reductions in AUC hunger and prospective consumption were identified in the 30 g condition. A similar pattern of results was observed for fullness and desire to eat. The results of this study show that a new composite satiety ingredient comprised of a viscous fibre and whole-grain corn flour can affect acute satiety responses in men and women.

  15. Neosaxitoxin in Rat Sciatic Block: Improved Therapeutic Index Using Combinations with Bupivacaine, with and without Epinephrine.

    PubMed

    Templin, Jay S; Wylie, Matthew C; Kim, Joseph D; Kurgansky, Katherine E; Gorski, Grzegorz; Kheir, John; Zurakowski, David; Corfas, Gabriel; Berde, Charles

    2015-10-01

    Neosaxitoxin (NeoSTX) is a site-1 sodium channel blocker undergoing clinical trials as a prolonged-duration local anesthetic. Rat sciatic block and intravenous infusion models were used to assess efficacy and local and systemic toxicities for NeoSTX in saline (NeoSTX-Saline), bupivacaine (Bup), and their combination (NeoSTX-Bup). Exploratory studies evaluated the effects of addition of epinephrine to NeoSTX-Bup (NeoSTX-Bup-Epi). Rats received percutaneous sciatic blocks with escalating doses of NeoSTX-Saline or NeoSTX-Bup. Sensory-nocifensive block was assessed using modified hotplate and Von Frey filaments. Motor-proprioceptive function was assessed by extensor postural thrust. Nerves were examined histologically after 7 days and scored on the Estebe-Myers scale. Median lethal dose was estimated for NeoSTX-Saline and in combinations. Accidental intravenous overdose was simulated in isoflurane-anesthetized, spontaneously breathing rats receiving NeoSTX-Saline (n = 6), Bup (n = 7), or NeoSTX-Bup (n = 13), with respiratory, hemodynamic, and electrocardiographic endpoints. Additional groups received blocks with NeoSTX-Bup-Epi (n = 80). Investigators were blinded for behavioral and histologic studies. NeoSTX-Bup produced more prolonged sensory and motor block compared with NeoSTX-Saline or Bup. NeoSTX-Bup-Epi further prolonged median time to near-complete recovery for 3 μg/kg NeoSTX-Bup (hotplate: 48 vs. 6 h, P < 0.001). With sciatic injections, addition of Bup did not worsen the systemic toxicity (median lethal dose) compared with NeoSTX-Saline. Intravenous NeoSTX-Saline infusion had significantly longer times to apnea, first arrhythmia, and asystole compared with Bup (P < 0.001 for each). Histologic injury scores overall were low for all groups, with median scores of 0 (interquartile range, 0 to 0) on a 5-point scale. NeoSTX-Bup and NeoSTX-Bup-Epi hold promise for prolonged-duration local anesthesia.

  16. Investigations of putative reproductive toxicity of low-dose exposures to vinclozolin in Wistar rats.

    PubMed

    Flick, Burkhard; Schneider, Steffen; Melching-Kollmuss, Stephanie; Fussell, Karma C; Gröters, Sibylle; Buesen, Roland; Strauss, Volker; van Ravenzwaay, Bennard

    2017-04-01

    The current investigation examines whether the fungicide vinclozolin, which has an anti-androgenic mode of action, is capable of disrupting endocrine homeostasis at very low doses. The data generated clarify whether a non-monotonic dose-response relationship exists to enhance the current debate about the regulation of endocrine disruptors. Moreover, it is part of a series of investigations assessing the dose-response relationship of single and combined administration of anti-androgenic substances. A pre-postnatal in vivo study design was chosen which was compliant with regulatory testing protocols. The test design was improved by additional endpoints addressing hormone levels, morphology and histopathological examinations. Doses were chosen to represent an effect level (20 mg/kg bw/d), the current NOAEL (4 mg/kg bw/d), and a dose close to the "ADI" (0.005 mg/kg bw/d) for the detection of a possible non-monotonic dose-response curve. Anti-androgenic changes were observable at the effect level but not at lower exposures. Nipple/areola counts appeared to be the most sensitive measure of effect, followed by male sex organ weights at sexual maturation, and finally gross and histopathological findings. The results indicate the absence of evidence for effects at low or very low dose levels. A non-monotonic dose-response relationship was not evident.

  17. SU-E-T-289: Dose-Volume-Effect Relationships for Lung Cancer Patients Treated with SBRT On a Prospective Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayyas, E; Brown, S; Liu, J

    Purpose: Stereotactic body radiotherapy (SBRT) is commonly used to treat early stage lung tumors. This study was designed to evaluate associations between dose, volume and clinical outcomes including analysis of both clinical toxicity scores and quality of life (QOL) data for non-small cell lung cancer patients treated with SBRT. Preliminary results are presented. Methods: Sixty-seven NSCLC patients, 46 primarily with early stage, and 21 with recurrent disease were treated with dose regimens consisting mainly of 12 Gy x 4 fractions, and 3 or 5 fractions at lower dose, for patients with recurrent disease (Table 1). Follow-up data is being collectedmore » at baseline, after treatment and at 3, 6, 12, 18 and 24 months post-treatment. Clinical follow-up data acquired to date was assessed using the Charlson Comorbidity Clinical and Toxicity Scoring forms. QOL data was evaluated using the EQ-5D, and FACT-TOI validated surveys. All outcomes surveys are collected within an “in-house” developed outcomes database. Results: The median follow-up was 3.5±0.8 months. Mean lung doses (MLD) were converted to BED-2 Gy using the linear-quadratic model with an alpha/beta=3.0. Average MLD was 3.7+3.1 Gy (range: 0.4–20.9 Gy). The percentages of patients with > grade 2 cough, dyspnea and fatigue were 13.3, 17.0, 6.3%, respectively. Preliminary analyses (at 3 months after SBRT) show a mild correlation between MLD > 2 Gy and > grade 2 cough (borderline significant) and dyspnea (significant, p<0.05). One patient was observed with a grade 3 cough. Given the short follow-up, tumor control is not yet assessable. Conclusion: The SBRT dose fractionation regimen of 12 Gy x 4 was well tolerated at early time points. Additional follow-up is required to assess the long-term clinical outcome efficacy and toxicity profiles of the dose regimen.« less

  18. Phase I Trial of Simultaneous In-Field Boost With Helical Tomotherapy for Patients With One to Three Brain Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodrigues, George, E-mail: george.rodrigues@lhsc.on.ca; Yartsev, Slav; Yaremko, Brian

    2011-07-15

    Purpose: Stereotactic radiosurgery is an alternative to surgical resection for selected intracranial lesions. Integrated image-guided intensity-modulated-capable radiotherapy platforms such as helical tomotherapy (HT) could potentially replace traditional radiosurgery apparatus. The present study's objective was to determine the maximally tolerated dose of a simultaneous in-field boost integrated with whole brain radiotherapy for palliative treatment of patients with one to three brain metastases using HT. Methods and Materials: The inclusion/exclusion criteria and endpoints were consistent with the Radiation Therapy Oncology Group 9508 radiosurgery trial. The cohorts were constructed with a 3 + 3 design; however, additional patients were enrolled in the lowermore » dose tolerable cohorts during the toxicity assessment periods. Whole brain radiotherapy (30 Gy in 10 fractions) was delivered with a 5-30-Gy (total lesion dose of 35-60 Gy in 10 fractions) simultaneous in-field boost delivered to the brain metastases. The maximally tolerated dose was determined by the frequency of neurologic Grade 3-5 National Cancer Institute Common Toxicity Criteria, version 3.0, dose-limiting toxicity events within each Phase I cohort. Results: A total of 48 patients received treatment in the 35-Gy (n = 3), 40-Gy (n = 16), 50-Gy (n = 15), 55-Gy (n = 8), and 60-Gy (n = 6) cohorts. No patients experienced dose-limiting toxicity events in any of the trial cohorts. The 3-month RECIST assessments available for 32 of the 48 patients demonstrated a complete response in 2, a partial response in 16, stable disease in 6, and progressive disease in 8 patients. Conclusion: The delivery of 60 Gy in 10 fractions to one to three brain metastases synchronously with 30 Gy whole brain radiotherapy was achieved without dose-limiting central nervous system toxicity as assessed 3 months after treatment. This approach is being tested in a Phase II efficacy trial.« less

  19. Association of Health Insurance Status and Vaccination Coverage among Adolescents 13-17 Years of Age.

    PubMed

    Lu, Peng-Jun; Yankey, David; Jeyarajah, Jenny; O'Halloran, Alissa; Fredua, Benjamin; Elam-Evans, Laurie D; Reagan-Steiner, Sarah

    2018-04-01

    To assess selected vaccination coverage among adolescents by health insurance status and other access-to-care characteristics. The 2015 National Immunization Survey-Teen data were used to assess vaccination coverage disparities among adolescents by health insurance status and other access-to-care variables. Multivariable logistic regression analysis and a predictive marginal modeling were conducted to evaluate associations between health insurance status and vaccination coverage. Overall, vaccination coverage was significantly lower among uninsured compared with insured adolescents for all vaccines assessed for except ≥3 doses of human papillomavirus vaccine (HPV) among male adolescents. Among adolescents 13-17 years of age, vaccination of uninsured compared with insured adolescents, respectively, for tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine was 77.4% vs 86.8%; for ≥1 dose of meningococcal conjugate vaccine was 72.9% vs 81.7%; for ≥1 dose of HPV was 38.8% vs 50.2% among male and 42.9% vs 63.8% among female adolescents; for 3 doses of HPV was 24.9% vs 42.8% among female adolescents. In addition, vaccination coverage differed by the following: type of insurance among insured adolescents, having a well-child visit at 11-12 years of age, and number of healthcare provider contacts in the past year. Uninsured were less likely than insured adolescents to be vaccinated for HPV (female: ≥1 dose and 3 doses; and male: ≥1 doses) after adjusting for confounding variables. Overall, vaccination coverage was lower among uninsured adolescents. HPV vaccination coverage was lower than tetanus toxoid, reduced content diphtheria toxoid, and acellular pertussis vaccine Tdap and meningococcal conjugate vaccine in both insured and uninsured adolescents. Wider implementation of effective evidence-based strategies is needed to help improve vaccination coverage among adolescents, particularly for those who are uninsured. Limitation of current federally funded vaccination programs or access to healthcare would be expected to erode vaccine coverage of adolescents. Published by Elsevier Inc.

  20. Numerical Analysis of Organ Doses Delivered During Computed Tomography Examinations Using Japanese Adult Phantoms with the WAZA-ARI Dosimetry System.

    PubMed

    Takahashi, Fumiaki; Sato, Kaoru; Endo, Akira; Ono, Koji; Ban, Nobuhiko; Hasegawa, Takayuki; Katsunuma, Yasushi; Yoshitake, Takayasu; Kai, Michiaki

    2015-08-01

    A dosimetry system for computed tomography (CT) examinations, named WAZA-ARI, is being developed to accurately assess radiation doses to patients in Japan. For dose calculations in WAZA-ARI, organ doses were numerically analyzed using average adult Japanese male (JM) and female (JF) phantoms with the Particle and Heavy Ion Transport code System (PHITS). Experimental studies clarified the photon energy distribution of emitted photons and dose profiles on the table for some multi-detector row CT (MDCT) devices. Numerical analyses using a source model in PHITS could specifically take into account emissions of x rays from the tube to the table with attenuation of photons through a beam-shaping filter for each MDCT device based on the experiment results. The source model was validated by measuring the CT dose index (CTDI). Numerical analyses with PHITS revealed a concordance of organ doses with body sizes of the JM and JF phantoms. The organ doses in the JM phantoms were compared with data obtained using previously developed systems. In addition, the dose calculations in WAZA-ARI were verified with previously reported results by realistic NUBAS phantoms and radiation dose measurement using a physical Japanese model (THRA1 phantom). The results imply that numerical analyses using the Japanese phantoms and specified source models can give reasonable estimates of dose for MDCT devices for typical Japanese adults.

  1. Environmental risks of radioactive discharges from a low-level radioactive waste disposal site at Dessel, Belgium.

    PubMed

    Batlle, J Vives I; Sweeck, L; Wannijn, J; Vandenhove, H

    2016-10-01

    The potential radiological impact of releases from a low-level radioactive waste (Category A waste) repository in Dessel, Belgium on the local fauna and flora was assessed under a reference scenario for gradual leaching. The potential impact situations for terrestrial and aquatic fauna and flora considered in this study were soil contamination due to irrigation with contaminated groundwater from a well at 70 m from the repository, contamination of the local wetlands receiving the highest radionuclide flux after migration through the aquifer and contamination of the local river receiving the highest radionuclide flux after migration through the aquifer. In addition, an exploratory study was carried out for biota residing in the groundwater. All impact assessments were performed using the Environmental Risk from Ionising Contaminants: Assessment and Management (ERICA) tool. For all scenarios considered, absorbed dose rates to biota were found to be well below the ERICA 10 μGy h -1 screening value. The highest dose rates were observed for the scenario where soil was irrigated with groundwater from the vicinity of the repository. For biota residing in the groundwater well, a few dose rates were slightly above the screening level but significantly below the dose rates at which the smallest effects are observed for those relevant species or groups of species. Given the conservative nature of the assessment, it can be concluded that manmade radionuclides deposited into the environment by the near surface disposal of category A waste at Dessel do not have a significant radiological impact to wildlife. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Sustained neuroprotection from a single intravitreal injection of PGJ₂ in a nonhuman primate model of nonarteritic anterior ischemic optic neuropathy.

    PubMed

    Miller, Neil R; Johnson, Mary A; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M; Bernstein, Steven L

    2014-10-08

    Prostaglandin J₂ (PGJ₂) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ₂ in a nonhuman primate model of NAION (pNAION). We assessed PGJ₂ toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ₂ or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ₂ or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. PGJ₂ caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ₂ used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ₂; however, the amplitudes returned to normal in all animals within 1 week. In all eyes, a single IVT dose of PGJ₂ administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and histological damage compared with vehicle-injected eyes (P = 0.03 for both VEP and PERG; P = 0.05 for axon counts). In nonhuman primates, PGJ₂ administered either intravenously or intravitreally produces no permanent toxicity at even four times the dose given for neuroprotection. Additionally, a single IVT dose of PGJ₂ is neuroprotective when administered up to 5 hours after induction of pNAION. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, R.

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  4. Self-reported history of stroke and long-term living conditions near air pollution sources: results of a national epidemiological study in Lebanon.

    PubMed

    Salameh, Pascale; Farah, Rita; Hallit, Souheil; Zeidan, Rouba Karen; Chahine, Mirna N; Asmar, Roland; Hosseini, Hassan

    2018-02-20

    Stroke is a disease related to high mortality and morbidity, particularly in developing countries. Some studies have linked self-reported indoor and outdoor pollution to stroke and mini-stroke, while some others showed no association. Our objective was to assess this association in Lebanon, a Middle Eastern developing country. A national cross-sectional study was conducted all over Lebanon. In addition to self-reported items of pollution exposure, we assessed potential predictors of stroke and mini-stroke, including sociodemographic characteristics, self-reported health information, and biological measurements. Moreover, we assessed dose-effect relationship of pollution items in relation with stroke. Self-reported indoor pollution exposure was associated with stroke and mini-stroke, with or without taking biological values into account. Moreover, we found a dose-effect relationship of exposure with risk of disease, but this effect did not reach statistical significance after adjustment for sociodemographics and biological characteristics. No association was found for any outdoor pollution item. Although additional studies would be necessary to confirm these findings, sensitizing the population about the effect of pollution on chronic diseases, working on reducing pollution, and improving air quality should be implemented to decrease the burden of the disease on the population and health system.

  5. Using the Monte Carlo method for assessing the tissue and organ doses of patients in dental radiography

    NASA Astrophysics Data System (ADS)

    Makarevich, K. O.; Minenko, V. F.; Verenich, K. A.; Kuten, S. A.

    2016-05-01

    This work is dedicated to modeling dental radiographic examinations to assess the absorbed doses of patients and effective doses. For simulating X-ray spectra, the TASMIP empirical model is used. Doses are assessed on the basis of the Monte Carlo method by using MCNP code for voxel phantoms of ICRP. The results of the assessment of doses to individual organs and effective doses for different types of dental examinations and features of X-ray tube are presented.

  6. An engineered human antibody to TNF (CDP571) for active Crohn's disease: a randomized double-blind placebo-controlled trial.

    PubMed

    Sandborn, W J; Feagan, B G; Hanauer, S B; Present, D H; Sutherland, L R; Kamm, M A; Wolf, D C; Baker, J P; Hawkey, C; Archambault, A; Bernstein, C N; Novak, C; Heath, P K; Targan, S R

    2001-05-01

    We evaluated CDP571, a humanized antibody to tumor necrosis factor, for the treatment of active Crohn's disease. One hundred sixty-nine patients with moderate-to-severe Crohn's disease were enrolled in a 24-week placebo-controlled trial. Patients were initially randomized to a single dose of 10 or 20 mg/kg CDP571 or placebo to assess dose response. Patients were then retreated with 10 mg/kg CDP571 or placebo every 8 or 12 weeks to assess subsequent dosing intervals. The primary endpoint was clinical response at week 2, defined as a decrease in the Crohn's Disease Activity Index score > or = 70 points. At week 2, clinical response occurred in 45% of CDP571-treated patients compared with 27% of patients in the placebo group (P = 0.023). Patients appeared to benefit from retreatment with CDP571 over 24 weeks, but not all of the results for secondary endpoints were statistically significant. The frequency of severe or serious adverse events was similar among all groups. CDP571 at an initial dose of 10 or 20 mg/kg is safe and effective for treatment of patients with moderate-to-severe Crohn's disease. Preliminary evidence suggests that retreatment with 10 mg/kg CDP571 at dose intervals of 8 or 12 weeks may also be beneficial, but additional studies are needed.

  7. U.S. EPA health assessment for diesel engine exhaust: a review.

    PubMed

    Ris, Charles

    2007-01-01

    In 2002 the U.S. Environmental Protection Agency (EPA) released a Health assessment Document for Diesel Engine Exhaust. The objective of this assessment was to examine the possible health hazards associated with exposure to diesel engine exhaust (DE). The assessment concludes that long-term inhalation exposure is likely to pose a lung cancer hazard to humans as inferred from epidemiologic and certain animal studies. Estimation of cancer potency from available epidemiology studies was not attempted because of the absence of a confident cancer dose-response and animal studies were not judged appropriate for cancer potency estimation. A noncancer chronic human health hazard is inferred from rodent studies which show dose-dependent inflammation and histopathology in the rat lung. For these noncancer effects a safe exposure concentration for humans was estimated. Short-term exposures were noted to cause irritation and inflammatory symptoms of a transient nature, these being highly variable across an exposed population. The assessment also indicates that there is emerging evidence for the exacerbation of existing allergies and asthma symptoms; however, as of 2002 the data were inadequate for quantitative dose-response analysis. The assessment conclusions are based on studies that used exposures from engines built prior to the mid 1990s. More recent engines without high-efficiency particle traps would be expected to have exhaust emissions with similar characteristics. With additional cancer epidemiology studies expected in 2007-2008, and a growing body of evidence for allergenicity and cardiovascular effects, future health assessments will have an expanded health effects data base to evaluate.

  8. Chimpanzee Adenovirus Vector Ebola Vaccine.

    PubMed

    Ledgerwood, Julie E; DeZure, Adam D; Stanley, Daphne A; Coates, Emily E; Novik, Laura; Enama, Mary E; Berkowitz, Nina M; Hu, Zonghui; Joshi, Gyan; Ploquin, Aurélie; Sitar, Sandra; Gordon, Ingelise J; Plummer, Sarah A; Holman, LaSonji A; Hendel, Cynthia S; Yamshchikov, Galina; Roman, Francois; Nicosia, Alfredo; Colloca, Stefano; Cortese, Riccardo; Bailer, Robert T; Schwartz, Richard M; Roederer, Mario; Mascola, John R; Koup, Richard A; Sullivan, Nancy J; Graham, Barney S

    2017-03-09

    The unprecedented 2014 epidemic of Ebola virus disease (EVD) prompted an international response to accelerate the availability of a preventive vaccine. A replication-defective recombinant chimpanzee adenovirus type 3-vectored ebolavirus vaccine (cAd3-EBO), encoding the glycoprotein from Zaire and Sudan species, that offers protection in the nonhuman primate model, was rapidly advanced into phase 1 clinical evaluation. We conducted a phase 1, dose-escalation, open-label trial of cAd3-EBO. Twenty healthy adults, in sequentially enrolled groups of 10 each, received vaccination intramuscularly in doses of 2×10 10 particle units or 2×10 11 particle units. Primary and secondary end points related to safety and immunogenicity were assessed throughout the first 8 weeks after vaccination; in addition, longer-term vaccine durability was assessed at 48 weeks after vaccination. In this small study, no safety concerns were identified; however, transient fever developed within 1 day after vaccination in two participants who had received the 2×10 11 particle-unit dose. Glycoprotein-specific antibodies were induced in all 20 participants; the titers were of greater magnitude in the group that received the 2×10 11 particle-unit dose than in the group that received the 2×10 10 particle-unit dose (geometric mean titer against the Zaire antigen at week 4, 2037 vs. 331; P=0.001). Glycoprotein-specific T-cell responses were more frequent among those who received the 2×10 11 particle-unit dose than among those who received the 2×10 10 particle-unit dose, with a CD4 response in 10 of 10 participants versus 3 of 10 participants (P=0.004) and a CD8 response in 7 of 10 participants versus 2 of 10 participants (P=0.07) at week 4. Assessment of the durability of the antibody response showed that titers remained high at week 48, with the highest titers in those who received the 2×10 11 particle-unit dose. Reactogenicity and immune responses to cAd3-EBO vaccine were dose-dependent. At the 2×10 11 particle-unit dose, glycoprotein Zaire-specific antibody responses were in the range reported to be associated with vaccine-induced protective immunity in challenge studies involving nonhuman primates, and responses were sustained to week 48. Phase 2 studies and efficacy trials assessing cAd3-EBO are in progress. (Funded by the Intramural Research Program of the National Institutes of Health; VRC 207 ClinicalTrials.gov number, NCT02231866 .).

  9. Digital radiography: optimization of image quality and dose using multi-frequency software.

    PubMed

    Precht, H; Gerke, O; Rosendahl, K; Tingberg, A; Waaler, D

    2012-09-01

    New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.

  10. Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maldonado, Delis

    2012-06-01

    The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorizedmore » Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes included increasing the time horizon beyond 1,050 years (yr), and using the radionuclide concentrations provided by the DOE-PPPO as inputs into the codes. The deterministic peak doses were evaluated within time horizons of 70 yr (for the Landfill Worker and Trespasser), 1,050 yr, 10,000 yr and 100,000 yr (for the Resident Farmer [onsite], Resident Gardener, Recreational User, Outdoor Worker and Offsite Resident Farmer) at the request of the DOE-PPPO. The time horizons of 10,000 yr and 100,000 yr were used at the request of the DOE-PPPO for informational purposes only. The probabilistic peak of the mean dose assessment was performed for the Offsite Resident Farmer using Technetium-99 (Tc-99) and a time horizon of 1,050 yr. The results of the deterministic analyses indicate that among all receptors and time horizons evaluated, the highest projected dose, 2,700 mrem/yr, occurred for the Resident Farmer (onsite) at 12,773 yr. The exposure pathways contributing to the peak dose are ingestion of plants, external gamma, and ingestion of milk, meat and soil. However, this receptor is considered an implausible receptor. The only receptors considered plausible are the Landfill Worker, Recreational User, Outdoor Worker and the Offsite Resident Farmer. The maximum projected dose among the plausible receptors is 220 mrem/yr for the Outdoor Worker and it occurs at 19,045 yr. The exposure pathways contributing to the dose for this receptor are external gamma and soil ingestion. The results of the probabilistic peak of the mean dose analysis for the Offsite Resident Farmer indicate that the average (arithmetic mean) of the peak of the mean doses for this receptor is 0.98 mrem/yr and it occurs at 1,050 yr. This dose corresponds to Tc-99 within the time horizon of 1,050 yr.« less

  11. Effects of consecutive irradiation and bias temperature stress in p-channel power vertical double-diffused metal oxide semiconductor transistors

    NASA Astrophysics Data System (ADS)

    Davidović, Vojkan; Danković, Danijel; Ilić, Aleksandar; Manić, Ivica; Golubović, Snežana; Djorić-Veljković, Snežana; Prijić, Zoran; Prijić, Aneta; Stojadinović, Ninoslav

    2018-04-01

    The mechanisms responsible for the effects of consecutive irradiation and negative bias temperature (NBT) stress in p-channel power vertical double-diffused MOS (VDMOS) transistors are presented in this paper. The investigation was performed in order to clarify the mechanisms responsible for the effects of specific kind of stress in devices previously subjected to the other kind of stress. In addition, it may help in assessing the behaviour of devices subjected to simultaneous irradiation and NBT stressing. It is shown that irradiation of previously NBT stressed devices leads to additional build-up of oxide trapped charge and interface traps, while NBT stress effects in previously irradiated devices depend on gate bias applied during irradiation and on the total dose received. In the cases of low-dose irradiation or irradiation without gate bias, the subsequent NBT stress leads to slight further device degradation. On the other hand, in the cases of devices previously irradiated to high doses or with gate bias applied during irradiation, NBT stress may have a positive role, as it actually anneals a part of radiation-induced degradation.

  12. United States Department of Energy National Nuclear Security Administration Sandia Field Office NESHAP Annual Report CY2014 for Sandia National Laboratories New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    evelo, stacie; Miller, Mark L.

    2015-05-01

    This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2014, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61, Subpart H--NATIONAL EMISSION STANDARDS FOR EMISSIONS OF RADIONUCLIDES OTHER THAN RADON FROM DEPARTMENT OF ENERGY FACILITIES. A description is given of the sources and their contributions to the overall dose assessment. In addition, the maximally exposed individual (MEI) radiological dose calculation and the population dose to localmore » and regional residents are discussed.« less

  13. The sensitivity of laboratory tests assessing driving related skills to dose-related impairment of alcohol: A literature review.

    PubMed

    Jongen, S; Vuurman, E F P M; Ramaekers, J G; Vermeeren, A

    2016-04-01

    Laboratory tests assessing driving related skills can be useful as initial screening tools to assess potential drug induced impairment as part of a standardized behavioural assessment. Unfortunately, consensus about which laboratory tests should be included to reliably assess drug induced impairment has not yet been reached. The aim of the present review was to evaluate the sensitivity of laboratory tests to the dose dependent effects of alcohol, as a benchmark, on performance parameters. In total, 179 experimental studies were included. Results show that a cued go/no-go task and a divided attention test with primary tracking and secondary visual search were consistently sensitive to the impairing effects at medium and high blood alcohol concentrations. Driving performance assessed in a simulator was less sensitive to the effects of alcohol as compared to naturalistic, on-the-road driving. In conclusion, replicating results of several potentially useful tests and their predictive validity of actual driving impairment should deserve further research. In addition, driving simulators should be validated and compared head to head to naturalistic driving in order to increase construct validity. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Interactions and Toxicity of Cu-Zn mixtures to Hordeum vulgare in Different Soils Can Be Rationalized with Bioavailability-Based Prediction Models.

    PubMed

    Qiu, Hao; Versieren, Liske; Rangel, Georgina Guzman; Smolders, Erik

    2016-01-19

    Soil contamination with copper (Cu) is often associated with zinc (Zn), and the biological response to such mixed contamination is complex. Here, we investigated Cu and Zn mixture toxicity to Hordeum vulgare in three different soils, the premise being that the observed interactions are mainly due to effects on bioavailability. The toxic effect of Cu and Zn mixtures on seedling root elongation was more than additive (i.e., synergism) in soils with high and medium cation-exchange capacity (CEC) but less than additive (antagonism) in a low-CEC soil. This was found when we expressed the dose as the conventional total soil concentration. In contrast, antagonism was found in all soils when we expressed the dose as free-ion activities in soil solution, indicating that there is metal-ion competition for binding to the plant roots. Neither a concentration addition nor an independent action model explained mixture effects, irrespective of the dose expressions. In contrast, a multimetal BLM model and a WHAM-Ftox model successfully explained the mixture effects across all soils and showed that bioavailability factors mainly explain the interactions in soils. The WHAM-Ftox model is a promising tool for the risk assessment of mixed-metal contamination in soils.

  15. Rapid Acute Dose Assessment Using MCNP6

    NASA Astrophysics Data System (ADS)

    Owens, Andrew Steven

    Acute radiation doses due to physical contact with a high-activity radioactive source have proven to be an occupational hazard. Multiple radiation injuries have been reported due to manipulating a radioactive source with bare hands or by placing a radioactive source inside a shirt or pants pocket. An effort to reconstruct the radiation dose must be performed to properly assess and medically manage the potential biological effects from such doses. Using the reference computational phantoms defined by the International Commission on Radiological Protection (ICRP) and the Monte Carlo N-Particle transport code (MCNP6), dose rate coefficients are calculated to assess doses for common acute doses due to beta and photon radiation sources. The research investigates doses due to having a radioactive source in either a breast pocket or pants back pocket. The dose rate coefficients are calculated for discrete energies and can be used to interpolate for any given energy of photon or beta emission. The dose rate coefficients allow for quick calculation of whole-body dose, organ dose, and/or skin dose if the source, activity, and time of exposure are known. Doses are calculated with the dose rate coefficients and compared to results from the International Atomic Energy Agency (IAEA) reports from accidents that occurred in Gilan, Iran and Yanango, Peru. Skin and organ doses calculated with the dose rate coefficients appear to agree, but there is a large discrepancy when comparing whole-body doses assessed using biodosimetry and whole-body doses assessed using the dose rate coefficients.

  16. Cost-Effectiveness of a Chemoprophylactic Intervention with Single Dose Rifampicin in Contacts of New Leprosy Patients

    PubMed Central

    Idema, Willemijn J.; Majer, Istvan M.; Pahan, David; Oskam, Linda; Polinder, Suzanne; Richardus, Jan Hendrik

    2010-01-01

    Background With 249,007 new leprosy patients detected globally in 2008, it remains necessary to develop new and effective interventions to interrupt the transmission of M. leprae. We assessed the economic benefits of single dose rifampicin (SDR) for contacts as chemoprophylactic intervention in the control of leprosy. Methods We conducted a single centre, double blind, cluster randomised, placebo controlled trial in northwest Bangladesh between 2002 and 2007, including 21,711 close contacts of 1,037 patients with newly diagnosed leprosy. We gave a single dose of rifampicin or placebo to close contacts, with follow-up for four years. The main outcome measure was the development of clinical leprosy. We assessed the cost effectiveness by calculating the incremental cost effectiveness ratio (ICER) between the standard multidrug therapy (MDT) program with the additional chemoprophylaxis intervention versus the standard MDT program only. The ICER was expressed in US dollars per prevented leprosy case. Findings Chemoprophylaxis with SDR for preventing leprosy among contacts of leprosy patients is cost-effective at all contact levels and thereby a cost-effective prevention strategy. In total, $6,009 incremental cost was invested and 38 incremental leprosy cases were prevented, resulting in an ICER of $158 per one additional prevented leprosy case. It was the most cost-effective in neighbours of neighbours and social contacts (ICER $214), slightly less cost-effective in next door neighbours (ICER $497) and least cost-effective among household contacts (ICER $856). Conclusion Chemoprophylaxis with single dose rifampicin given to contacts of newly diagnosed leprosy patients is a cost-effective intervention strategy. Implementation studies are necessary to establish whether this intervention is acceptable and feasible in other leprosy endemic areas of the world. PMID:21072235

  17. In vivo safety and tolerability study of QR-441(a) using three dose formulations and three routes of administration in chickens.

    PubMed

    Cummings, Timothy S; Guralnik, Mario; Rosenbloom, Richard A; Petteruti, Michael P; Digian, Kelly; Lefante, Carolyn

    2007-01-01

    The current study assessed the safety, tolerability, and palatability of the experimental drug QR-441(a) using three dose formulations and three routes of administration. A 4-day study was carried out using a total of 132 chickens. A total of 11 groups were formed (12 chickens per group) subjected to varying concentrations and routes of administration of QR-441(a). Chickens were given a high, medium, or low dose of QR-441(a) in either feed, water, or both for a period of 4 days. In addition, one group was dosed intranasally, one drop per nostril four times a day. Although no lesions were found to suggest toxicity or irritability, the medium- and high-dose water groups reduced their water intake. This reduction in water intake suggests that chickens may find the medium and high water doses unpalatable. There was no reduction in water intake in the low-dose water groups or in any of the formulated feed groups. There was also no evidence of toxicity or irritability in the nasal-dose group. These data support the use of the low, medium, and high doses in feed and the use of the low-dose concentration in water for the administration of QR-441(a). The data also suggest that QR-441(a) can be administered intranasally without the presence of any adverse events.

  18. Toxicity of TiO2 nanoparticles on soil nitrification at environmentally relevant concentrations: Lack of classical dose-response relationships.

    PubMed

    Simonin, Marie; Martins, Jean M F; Le Roux, Xavier; Uzu, Gaëlle; Calas, Aude; Richaume, Agnès

    2017-03-01

    Titanium-dioxide nanoparticles (TiO 2 -NPs) are increasingly released in agricultural soils through, e.g. biosolids, irrigation or nanoagrochemicals. Soils are submitted to a wide range of concentrations of TiO 2 -NPs depending on the type of exposure. However, most studies have assessed the effects of unrealistically high concentrations, and the dose-response relationships are not well characterized for soil microbial communities. Here, using soil microcosms, we assessed the impact of TiO 2 -NPs at concentrations ranging from 0.05 to 500 mg kg -1  dry-soil, on the activity and abundance of ammonia-oxidizing archaea (AOA) and bacteria (AOB), and nitrite-oxidizing bacteria (Nitrobacter and Nitrospira). In addition, aggregation and oxidative potential of TiO 2 -NPs were measured in the spiking suspensions, as they can be important drivers of TiO 2 -NPs toxicity. After 90 days of exposure, non-classical dose-response relationships were observed for nitrifier abundance or activity, making threshold concentrations impossible to compute. Indeed, AOA abundance was reduced by 40% by TiO 2 -NPs whatever the concentration, while Nitrospira was never affected. Moreover, AOB and Nitrobacter abundances were decreased mainly at intermediate concentrations nitrification was reduced by 25% at the lowest (0.05 mg kg -1 ) and the highest (100 and 500 mg kg -1 ) TiO 2 -NPs concentrations. Path analyses indicated that TiO 2 -NPs affected nitrification through an effect on the specific activity of nitrifiers, in addition to indirect effects on nitrifier abundances. Altogether these results point out the need to include very low concentrations of NPs in soil toxicological studies, and the lack of relevance of classical dose-response tests and ecotoxicological dose metrics (EC50, IC50…) for TiO 2 -NPs impact on soil microorganisms.

  19. AspiriN To Inhibit SEPSIS (ANTISEPSIS) randomised controlled trial protocol.

    PubMed

    Eisen, Damon P; Moore, Elizabeth M; Leder, Karin; Lockery, Jessica; McBryde, Emma S; McNeil, John J; Pilcher, David; Wolfe, Rory; Woods, Robyn L

    2017-01-20

    Sepsis is a leading global cause of morbidity and mortality, and is more common at the extremes of age. Moreover, the cost of in-hospital care for elderly patients with sepsis is significant. There are indications from experimental and observational studies that aspirin may reduce inflammation associated with infection. This paper describes the rationale and design of the AspiriN To Inhibit SEPSIS (ANTISEPSIS) trial, a substudy of ASPirin in Reducing Events in the Elderly (ASPREE). ANTISEPSIS primarily aims to determine whether low-dose aspirin reduces sepsis-related deaths in older people. Additionally, it will assess whether low-dose aspirin reduces sepsis-related hospitalisations and sepsis-related Intensive Care Unit (ICU) admissions. ASPREE is a double-blinded, randomised, placebo-controlled primary prevention trial that will determine whether daily low-dose aspirin extends disability-free longevity in 19 000 healthy older people recruited in Australia and the USA. The ANTISEPSIS substudy involves additional ASPREE trial data collection to assess the impact of daily low-dose aspirin on sepsis-related events in the 16 703 ASPREE participants aged 70 years and over, recruited in Australia. The intervention is a daily 100 mg dose of enteric-coated aspirin versus matching placebo, with 1:1 randomisation. The primary outcome for the ANTISEPSIS substudy is the incidence of sepsis-related death in eligible patients. The incidence of sepsis-related hospital and ICU admissions are secondary outcomes. ANTISEPSIS is to be conducted between 2012 and 2018. This substudy will determine whether aspirin, an inexpensive and accessible therapy, safely reduces sepsis-related deaths and hospitalisations in older Australians. If shown to be the case, this would have profound effects on the health of older Australians. Pre-results, ACTRN12613000349741. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Efficacy and safety of combination therapy: repaglinide plus metformin versus nateglinide plus metformin.

    PubMed

    Raskin, Philip; Klaff, Leslie; McGill, Janet; South, Stephen A; Hollander, Priscilla; Khutoryansky, Naum; Hale, Paula M

    2003-07-01

    An open-label, parallel-group, randomized, multicenter trial was conducted to compare efficacy and safety of repaglinide versus nateglinide, when used in a combination regimen with metformin for treatment of type 2 diabetes. Enrolled patients (n = 192) had HbA(1c) >7% and < or =12% during previous treatment with a sulfonylurea, metformin, or low-dose Glucovance (glyburide < or =2.5 mg, metformin < or =500 mg). After a 4-week metformin run-in therapy period (doses escalated to 1,000 mg b.i.d.), patients were randomized to addition of repaglinide (n = 96) (1 mg/meal, maximum 4 mg/meal) or nateglinide (n = 96) (120 mg/meal, reduced to 60 mg if needed) to the regimen for 16 weeks. Glucose, insulin, and glucagon were assessed after a liquid test meal at baseline and week 16. Final HbA(1c) values were lower for repaglinide/metformin treatment than for nateglinide/metformin (7.1 vs. 7.5%). Repaglinide/metformin therapy showed significantly greater mean reductions of HbA(1c) (-1.28 vs. -0.67%; P < 0.001) and of fasting plasma glucose (FPG) (-39 vs. -21 mg/dl; P = 0.002). Self-monitoring of blood glucose profiles were significantly lower for repaglinide/metformin before breakfast, before lunch, and at 2:00 A.M. Changes in the area under the curve of postprandial glucose, insulin, or glucagon peaks after a test meal were not significantly different for the two treatment groups during this study. Median final doses were 5.0 mg/day for repaglinide and 360 mg/day for nateglinide. Safety assessments were comparable for the two regimens. The addition of repaglinide to metformin therapy resulted in reductions of HbA(1c) and FPG values that were significantly greater than the reductions observed for addition of nateglinide.

  1. Cardiohemodynamic and electrophysiological effects of a selective EP4 receptor agonist ONO--AE1--329 in the halothane-anesthetized dogs.

    PubMed

    Nomura, Hiroaki; Nakamura, Yuji; Cao, Xin; Honda, Atsushi; Katagi, Jun; Ohara, Hiroshi; Izumi-Nakaseko, Hiroko; Satoh, Yoshioki; Ando, Kentaro; Sugiyama, Atsushi

    2015-08-15

    Cardiovascular effects of a highly selective prostaglandin E2 type 4 (EP4) receptor agonist ONO-AE1-329 were assessed with the halothane-anesthetized dogs (n=6). ONO-AE1-329 was intravenously infused in three escalating doses of 0.3, 1 and 3ng/kg/min for 10min with a pause of 20min between the doses. The low dose of 0.3ng/kg/min significantly increased maximum upstroke velocity of left ventricular pressure by 18% at 20min, indicating increase of ventricular contractility. The middle dose of 1ng/kg/min significantly decreased total peripheral resistance by 24% and left ventricular end-diastolic pressure by 32% at 10min, indicating dilation of arteriolar resistance vessels and venous capacitance ones, respectively; and increased cardiac output by 25% at 10min in addition to the change induced by the low dose. The high dose of 3ng/kg/min increased heart rate by 34% at 10min; decreased mean blood pressure by 14% at 10min and atrioventricular nodal conduction time by 13% at 5min; and shortened left ventricular systolic period by 8% at 10min and electromechanical coupling defined as an interval from completion of repolarization to the start of ventricular diastole by 39% at 10min in addition to the changes induced by the middle dose. No significant change was detected in a ventricular repolarization period. These results indicate that ONO-AE1-329 may possess a similar cardiovascular profile to typical phosphodiesterase 3 inhibitors as an inodilator, and suggest that EP4 receptor stimulation can become an alternative strategy for the treatment of congestive heart failure. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Chasing Ghosts in Space Radiobiology Research: The Lost Focus on Non-Targeted Effects

    NASA Astrophysics Data System (ADS)

    Cucinotta, Francis; Saganti, Premkumar; Cacao, Eliedonna

    2016-07-01

    The doses and dose-rates of astronaut exposures to galactic cosmic rays (GCR) are accurately known, and lead to particle hits per cell nucleus from high charge and energy (HZE) particles of much less than one hit per cell per week. A large number of experiments have shown that additivity of biological effects is a valid assumption for space radiation exposures, while experiments at higher doses and dose-rates than occur in space continue to be a focus of the majority of space radiobiology research. Furthermore HZE particle exposures with mono-energetic particles manifest themselves as a mixed-radiation field due to the contributions of delta-rays and the random impact parameter of a particles track core to DNA and non-DNA targets in cells and tissues. The mixed-field manifestation of mono-energetic HZE particle exposures is well known from theoretical studies of microdosimetry and track structure. Additional mixed-field effects occur for single species experiments due to nuclear fragmentation in particle accelerator beam-lines and biological samples along with energy straggling. In contrast to these well known aspects of space radiobiology there are many open questions on the contribution of non-targeted effects to low dose and dose-rate exposures. Non-targeted effects (NTEs) include bystander effects and genomic instability, and have been shown to be the most important outstanding question for reducing uncertainties in space radiation cancer risk assessment. The dose-rate and radiation quality dependence of NTE's has not been established, while there is an over-arching need to develop 21st century experimental models of human cancer risk. We review possible mechanisms of NTE's and how new experiments to address these issues could be designed.

  3. Quality control in interstitial brachytherapy of the breast using pulsed dose rate: treatment planning and dose delivery with an Ir-192 afterloading system.

    PubMed

    Mangold, C A; Rijnders, A; Georg, D; Van Limbergen, E; Pötter, R; Huyskens, D

    2001-01-01

    In the Radiotherapy Department of Leuven, about 20% of all breast cancer patients treated with breast conserving surgery and external radiotherapy receive an additional boost with pulsed dose rate (PDR) Ir-192 brachytherapy. An investigation was performed to assess the accuracy of the delivered PDR brachytherapy treatment. Secondly, the feasibility of in vivo measurements during PDR dose delivery was investigated. Two phantoms are manufactured to mimic a breast, one for thermoluminescent dosimetry (TLD) measurements, and one for dosimetry using radiochromic films. The TLD phantom allows measurements at 34 dose points in three planes including the basal dose points. The film phantom is designed in such a way that films can be positioned in a plane parallel and orthogonal to the needles. The dose distributions calculated with the TPS are in good agreement with both TLD and radiochromic film measurements (average deviations of point doses <+/-5%). However, close to the interface tissue-air the dose is overestimated by the TPS since it neglects the finite size of a breast and the associated lack of backscatter (average deviations of point doses -14%). Most deviations between measured and calculated doses, are in the order of magnitude of the uncertainty associated with the source strength specification, except for the point doses measured close to the skin. In vivo dosimetry during PDR brachytherapy treatment was found to be a valuable procedure to detect large errors, e.g. errors caused by an incorrect data transfer.

  4. A Biomathematical Model of Lymphopoiesis and Its Application to Acute and Chronic Irradiation Assessment

    NASA Technical Reports Server (NTRS)

    Hu, Shaowen; Cucinotta, Francis A.

    2010-01-01

    After the events of September 11, 2001, there is an increasing concern of the occurrence of radiological terrorism that may result in significant casualties in densely populated areas. Much effort has been made to establish various biomarkers to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios, which are demanded for effective medical management and treatment of the exposed victims. Among these the count of lymphocytes in peripheral blood and their depletion kinetics are the most important early indicators of the severity of the radiation injury. In this study, we examine a biomathematical model of lymphopoiesis which has been successfully utilized to simulate and interpret experimental data of acute and chronic irradiations on rodents [1]. With revised parameters for humans, we find this model can reproduce several sets of clinical lymphocyte data of accident victims over a wide range of absorbed doses. In addition, the absolute lymphocyte counts and the depletion rate constants calculated by this model also show good correlation with the Guskova formula and the Goans model, the two empirical tools which have been widely recognized for early estimation of the exposed dose after radiation accidents [2]. We also use the model to analyze the hematological data of the Techa River residents which were exposed to chronic low-dose irradiation during 1950-1956 [3]. This model can serve as a computational tool in radiation accident management, military operations involving nuclear warfare, radiation therapy, and space radiation risk assessment.

  5. Acute and subacute oral toxicity of polychlorinated diphenyl sulfides in mice: determining LD50 and assessing the status of hepatic oxidative stress.

    PubMed

    Zhang, Xuesheng; Liu, Fu; Chen, Binyuan; Li, Ying; Wang, Zunyao

    2012-07-01

    Polychlorinated diphenyl sulfides (PCDPSs), a series of dioxin-like compounds, have been detected in various environmental samples. However, information on the toxicity of these compounds is limited. In the present study, the toxic effects of PCDPSs were assessed after acute and subacute exposure in mice. Relationships between acute toxicity, number, and position of substituted Cl atoms were assessed. In the acute study, 11 types of PCDPSs were administered to female Kunming mice by gavage, and median lethal doses (LD50s) were determined by the Karber method. Results indicated that the LD50s of lower substituted PCDPSs were smaller than higher substituted PCDPSs. Substituted positions also influenced the LD50 of PCDPSs. Terminal necropsy showed increased relative liver weights and decreased relative kidney weights. Histological examination of livers demonstrated swollen cells, inflammation, vacuolization, and necrosis. In the 28-d subacute exposure tests, 11 types of PCDPSs were dissolved in corn oil and administered to mice at doses of 1, 10, and 100 mg/kg. Superoxide dismutase (SOD) activity and malondialdehyde (MDA) levels in mouse liver were determined after the exposure period. Results suggested that lower substituted PCDPSs decreased SOD activity in the high-dose groups compared with controls, and MDA level in the 100-mg/kg dose group was significantly increased. In addition, acute toxicity of PCDPSs partly corresponded to the hepatic oxidative damage observed. Copyright © 2012 SETAC.

  6. The use of paracetamol (acetaminophen) among a community sample of people with chronic non-cancer pain prescribed opioids.

    PubMed

    Hoban, B; Larance, B; Gisev, N; Nielsen, S; Cohen, M; Bruno, R; Shand, F; Lintzeris, N; Hall, W; Farrell, M; Degenhardt, L

    2015-11-01

    The regular use of simple analgesics in addition to opioids such as paracetamol (or acetaminophen) is recommended for persistent pain to enhance analgesia. Few studies have examined the frequency and doses of paracetamol among people with chronic non-cancer pain including use above the recommended maximum daily dose. To assess (i) the prevalence of paracetamol use among people with chronic non-cancer pain prescribed opioids, (ii) assess the prevalence of paracetamol use above the recommended maximum daily dose and (iii) assess correlates of people who used paracetamol above the recommended maximum daily dose including: age, gender, income, education, pain severity and interference, use of paracetamol/opioid combination analgesics, total opioid dose, depression, anxiety, pain self-efficacy or comorbid substance use, among people prescribed opioids for chronic non-cancer pain. This study draws on baseline data collected for the Pain and Opioids IN Treatment (POINT) study and utilises data from 962 interviews and medication diaries. The POINT study is national prospective cohort of people with chronic non-cancer pain prescribed opioids. Participants were recruited from randomly selected pharmacies across Australia. Sixty-three per cent of the participants had used paracetamol in the past week (95% CI = 59.7-65.8). Among the paracetamol users 22% (95% CI = 19.3-24.6) had used paracetamol/opioid combination analgesics and 4.8% (95% CI = 3.6-6.3) had used paracetamol above the recommended maximum daily dose (i.e. > 4000 mg/day). Following binomial logistic regression (χ(2) = 25.98, df = 10, p = 0.004), people who had taken above the recommended maximum daily dose were less likely to have low income (AOR = 0.52, 95% CI = 0.27-0.99), more likely to use paracetamol/opioid combination analgesics (AOR = 2.01, 95% CI = 1.02-3.98) and more likely to take a higher opioid dose (AOR = 1.00, 95% CI = 1.00-1.01). The majority of people with chronic non-cancer pain prescribed opioids report using paracetamol appropriately. High income, use of paracetamol/opioid combination analgesics and higher opioid dose were independently associated with paracetamol use above the recommended maximum daily dose. © 2015 John Wiley & Sons Ltd.

  7. Assessment of in vivo systemic toxicity and biodistribution of iron-doped silica nanoshells.

    PubMed

    Mendez, Natalie; Liberman, Alexander; Corbeil, Jacqueline; Barback, Christopher; Viveros, Robert; Wang, James; Wang-Rodriguez, Jessica; Blair, Sarah L; Mattrey, Robert; Vera, David; Trogler, William; Kummel, Andrew C

    2017-04-01

    Silica nanoparticles are an emerging class of biomaterials which may be used as diagnostic and therapeutic tools for biomedical applications. In particular, hollow silica nanoshells are attractive due to their hollow core. Approximately 70% of a 500 nm nanoshell is hollow, therefore more particles can be administered on a mg/kg basis compared to solid nanoparticles. Additionally, their nanoporous shell permits influx/efflux of gases and small molecules. Since the size, shape, and composition of a nanoparticle can dramatically alter its toxicity and biodistribution, the toxicology of these nanomaterials was assessed. A single dose toxicity study was performed in vivo to assess the toxicity of 500 nm iron-doped silica nanoshells at clinically relevant doses of 10-20 mg/kg. This study showed that only a trace amount of silica was detected in the body 10 weeks post-administration. The hematology, biochemistry and pathological results show that the nanoshells exhibit no acute or chronic toxicity in mice. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Assessment of four methods to estimate surface UV radiation using satellite data, by comparison with ground measurements from four stations in Europe

    NASA Astrophysics Data System (ADS)

    Arola, Antti; Kalliskota, S.; den Outer, P. N.; Edvardsen, K.; Hansen, G.; Koskela, T.; Martin, T. J.; Matthijsen, J.; Meerkoetter, R.; Peeters, P.; Seckmeyer, G.; Simon, P. C.; Slaper, H.; Taalas, P.; Verdebout, J.

    2002-08-01

    Four different satellite-UV mapping methods are assessed by comparing them against ground-based measurements. The study includes most of the variability found in geographical, meteorological and atmospheric conditions. Three of the methods did not show any significant systematic bias, except during snow cover. The mean difference (bias) in daily doses for the Rijksinstituut voor Volksgezondheid en Milieu (RIVM) and Joint Research Centre (JRC) methods was found to be less than 10% with a RMS difference of the order of 30%. The Deutsches Zentrum für Luft- und Raumfahrt (DLR) method was assessed for a few selected months, and the accuracy was similar to the RIVM and JRC methods. It was additionally used to demonstrate how spatial averaging of high-resolution cloud data improves the estimation of UV daily doses. For the Institut d'Aéronomie Spatiale de Belgique (IASB) method the differences were somewhat higher, because of their original cloud algorithm. The mean difference in daily doses for IASB was about 30% or more, depending on the station, while the RMS difference was about 60%. The cloud algorithm of IASB has been replaced recently, and as a result the accuracy of the IASB method has improved. Evidence is found that further research and development should focus on the improvement of the cloud parameterization. Estimation of daily exposures is likely to be improved if additional time-resolved cloudiness information is available for the satellite-based methods. It is also demonstrated that further development work should be carried out on the treatment of albedo of snow-covered surfaces.

  9. Environmentally relevant mixtures in cumulative assessments: an acute study of toxicokinetics and effects on motor activity in rats exposed to a mixture of pyrethroids.

    PubMed

    Starr, James M; Scollon, Edward J; Hughes, Michael F; Ross, David G; Graham, Stephen E; Crofton, Kevin M; Wolansky, Marcelo J; Devito, Michael J; Tornero-Velez, Rogelio

    2012-12-01

    Due to extensive use, human exposure to multiple pyrethroid insecticides occurs frequently. Studies of pyrethroid neurotoxicity suggest a common mode of toxicity and that pyrethroids should be considered cumulatively to model risk. The objective of this work was to use a pyrethroid mixture that reflects human exposure to common pyrethroids to develop comparative toxicokinetic profiles in rats, and then model the relationship between brain concentration and motor activity. Data from a national survey of child care centers were used to make a mixture reflecting proportions of the most prevalent pyrethroids: permethrin, cypermethrin, β-cyfluthrin, deltamethrin, and esfenvalerate. The mixture was administered orally at one of two concentrations (11.2 and 27.4 mg/kg) to adult male rats. At intervals from 1 to 24h, motor activity was assessed and the animals were sacrificed. Pyrethroid concentrations were measured in the blood, liver, fat, and brain. After controlling for dose, there were no differences in any tissue concentrations, except blood at the initial time point. Elimination half-lives for all pyrethroids in all tissues were < 7h. Brain concentrations of all pyrethroids (when cis- and trans-permethrin were pooled) at the initial time point were proportional to their relative doses. Decreases in motor activity indicated dose additivity, and the relationship between pyrethroid brain concentration and motor activity was described by a four-parameter sigmoidal E(max) model. This study links environmental data with toxicokinetic and neurobehavioral assays to support cumulative risk assessments of pyrethroid pesticides. The results support the additive model of pyrethroid effect on motor activity and suggest that variation in the neurotoxicity of individual pyrethroids is related to toxicodynamic rather than toxicokinetic differences.

  10. Impact of the Fenton-like treatment on the microbial community of a diesel-contaminated soil.

    PubMed

    Polli, Flavia; Zingaretti, Daniela; Crognale, Silvia; Pesciaroli, Lorena; D'Annibale, Alessandro; Petruccioli, Maurizio; Baciocchi, Renato

    2018-01-01

    Fenton-like treatment (FLT) is an ISCO technique relying on the iron-induced H 2 O 2 activation in the presence of additives aimed at increasing the oxidant lifetime and maximizing iron solubility under natural soil pH conditions. The efficacy of FLT in the clean-up of hydrocarbon-contaminated soils is well established at the field-scale. However, a better assessment of the impact of the FLT on density, diversity and activity of the indigenous soil microbiota, might provide further insights into an optimal combination between FLT and in-situ bioremediation (ISB). The aim of this work was to assess the impacts of FLT on the microbial community of a diesel-contaminated soil collected nearby a gasoline station. Different FLT conditions were tested by varying either the H 2 O 2 concentrations (2 and 6%) or the oxidant application mode (single or double dosage). The impact of these treatments on the indigenous microbial community was assessed immediately after the Fenton-like treatment and after 30, 60 and 90 d and compared with enhanced natural attenuation (ENA). After FLT, a dramatic decrease in bacterial density, diversity and functionality was evident. Although in microcosms with double dosing at 2% H 2 O 2 a delayed recovery of the indigenous microbiota was observed as compared to those subjected to single oxidant dose, after 60 d incubation the respiration rate increased from 0.036 to 0.256 μg CCO 2 g -1 soil h -1 . Irrespective of the oxidant dose, best degradation results after 90 d incubation (around 80%) were observed with combined FLT, relying on double oxidant addition, and bioremediation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. [Efficacy of glycopyrronium bromide and scopolamine hydrobromide in patients with death rattle: a randomized controlled study].

    PubMed

    Likar, Rudolf; Rupacher, Ernst; Kager, Hans; Molnar, Mario; Pipam, Wofgang; Sittl, Reinhard

    2008-01-01

    Death rattle is an extremely distressing symptom for the dying patient and for his environment. The aim of this study was to assess the efficacy of glycopyrronium bromide as compared with scopolamine hydrobromide in alleviating death rattle in terminal cancer patients with cognitive impairment. In a randomized, controlled study design patients were allocated in two groups. Group A received scopolamine hydrobromide in a dose of 0.5 mg intravenously every 6 hours for a period of 12 hours, group B received glycopyrronium bromide 0.4 mg every 6 hours for a period of 12 hours. In addition, standardized sedatives were administered as required and the analgesic therapy continued either orally or, if necessary, subcutaneously or intravenously in equipotent doses. Every 2 hours death rattle was assessed and rated on a scale of 1 to 5 (1 = audible breathing noises, 5 = very severe rattling noises). In addition, restlessness and expressions of pain were assessed and rated on a scale of 1 to 3 (1 = mild, 2 = moderate, 3 = severe). 13 patients were included in the study, 7 patients were allocated to group A and 6 patients to group B. There were no significant differences in demographic data, age, weight and diagnosis distribution between the two groups. Group B demonstrated a significant reduction of death rattle in the first 12 hours (p = 0.029) in comparison to group A. There were no significant differences concerning the side effects (restlessness, expressions of pain) in both groups. Glycopyrronium bromide given in a dose of 0,4 mg every six hours demonstrated a significant reduction of death rattle compared to scopolamine hydrobromide. Concerning side effects (restlessness, expressions of pain) there was no difference between both substances.

  12. Phase I study of adenovirus p53 administered by bronchoalveolar lavage in patients with bronchioloalveolar cell lung carcinoma: ECOG 6597.

    PubMed

    Keedy, Vicki; Wang, Wei; Schiller, Joan; Chada, Sunil; Slovis, Bonnie; Coffee, Keith; Worrell, John; Thet, Lyn A; Johnson, David H; Carbone, David P

    2008-09-01

    This pilot phase I trial evaluated the safety and maximum-tolerated dose of p53 gene transfer using an adenovirus vector (Ad-p53) delivered via bronchoalveolar lavage (BAL) to patients with bronchioloalveolar lung carcinoma (BAC). Patients were initially administered two treatments of Ad-p53 to a single involved lobe, beginning at 2 x 10(9) viral particles (vp) per dose and escalated to a maximum of 2 x 10(12) vp. If a clinical benefit was seen and the treatment was well tolerated, additional doses could be administered to additional lobes. Twenty-five patients were treated at doses between 2 x 10(9) and 2 x 10(12) vp. At 2 x 10(12) vp, one patient experienced grade 4 pulmonary toxicity, and one patient died 25 days after his second cycle; therefore, a cohort of 10 patients was treated at the recommended phase II dose of 5 x 10(11) vp, with no grade 4 toxicity observed. The most frequent toxicities included low-grade fever, hypoxia, and dyspnea. Of the 23 assessable patients, 16 had stable disease as their best response. Subjective improvement in breathing was noted in eight patients. Limited distribution of vector was observed, with transient detection in patient sputum for 1 to 2 days after administration. Ad-p53 can be administered safely by BAL at 5 x 10(11) vp with repeated dosing. Stabilization of disease and symptomatic improvement may warrant further studies of Ad-p53 or other adenoviruses administered by BAL in patients with BAC.

  13. Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grimes, Joshua, E-mail: grimes.joshua@mayo.edu; Celler, Anna

    2014-09-15

    Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming themore » same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.« less

  14. TU-G-BRA-01: Assessing Radiation-Induced Reductions in Regional Lung Perfusion Following Stereotactic Radiotherapy for Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGurk, R; Green, R; Lawrence, M

    2015-06-15

    Purpose: The dose-dependent nature of radiation therapy (RT)-induced lung injury following hypo-fractionated stereotactic RT is unclear. We herein report preliminary results of a prospective study assessing the magnitude of RT-induced reductions in regional lung perfusion following hypo-fractionated stereotactic RT. Methods: Four patients undergoing hypo-fractionated stereotactic lung RT (SBRT: 12 Gy x 4 fractions or 10 Gy x 5 fractions) had a pre-treatment SPECT (single-photon emission computed tomography) perfusion scan providing a 3D map of regional lung perfusion. Scans were repeated 3–6 months post-treatment. Pre- and post SPECT scans were registered to the planning CT scan (and hence the 3D dosemore » data). Changes in regional perfusion (counts per cc on the pre-post scans) were computed in regions of the lung exposed to different doses of radiation (in 5 Gy intervals), thus defining a dose-response function. SPECT scans were internally normalized to the regions receiving <5 Gy. Results: At 3 months post-RT, the changes in perfusion are highly variable. At 6 months, there is a consistent dose-dependent reduction in regional perfusion. The average percent decline in regional perfusion was 10% at 15–20 Gy, 20% at 20–25 Gy, and 30% at 25–30 Gy representing a relatively linear dose response with an approximate 2% reduction per Gray for doses in excess of 10 Gy. There was a subtle increase in perfusion in the lung receiving <10 Gy. Conclusion: Hypo-fractionated stereotactic RT appears to cause a dose-dependent reduction in regional lung perfusion. There appears to be a threshold effect with no apparent perfusion loss at doses <10 Gy, though this might be in part due to the normalization technique used. Additional data is needed from a larger number of patients to better assess this issue. This sort of data can be used to assist optimizing RT treatment plans that minimize the risk of lung injury. Partly supported by the NIH (CA69579) and the Lance Armstrong Foundation.« less

  15. SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, P; Corwin, F; Ghita, M

    Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examinationmore » mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z-direction in particular.« less

  16. A water extract of Mucuna pruriens provides long-term amelioration of parkinsonism with reduced risk for dyskinesias.

    PubMed

    Lieu, Christopher A; Kunselman, Allen R; Manyam, Bala V; Venkiteswaran, Kala; Subramanian, Thyagarajan

    2010-08-01

    Dopaminergic anti-parkinsonian medications, such as levodopa (LD) cause drug-induced dyskinesias (DID) in majority of patients with Parkinson's disease (PD). Mucuna pruriens, a legume extensively used in Ayurveda to treat PD, is reputed to provide anti-parkinsonian benefits without inducing DID. We compared the behavioral effects of chronic parenteral administration of a water extract of M. pruriens seed powder (MPE) alone without any additives, MPE combined with the peripheral dopa-decarboxylase inhibitor (DDCI) benserazide (MPE+BZ), LD+BZ and LD alone without BZ in the hemiparkinsonian rat model of PD. A battery of behavioral tests assessed by blinded investigators served as outcome measures in these randomized trials. In experiment 1, animals that received LD+BZ or MPE+BZ at high (6mg/kg) and medium (4mg/kg) equivalent doses demonstrated significant alleviation of parkinsonism, but, developed severe dose-dependent DID. LD+BZ at low doses (2mg/kg) did not provide significant alleviation of parkinsonism. In contrast, MPE+BZ at an equivalent low dose significantly ameliorated parkinsonism. In experiment 2, MPE without any additives (12mg/kg and 20mg/kg LD equivalent dose) alleviated parkinsonism with significantly less DID compared to LD+BZ or MPE+BZ. In experiment 3, MPE without additives administered chronically provided long-term anti-parkinsonian benefits without causing DID. In experiment 4, MPE alone provided significantly more behavioral benefit when compared to the equivalent dose of synthetic LD alone without BZ. In experiment 5, MPE alone reduced the severity of DID in animals initially primed with LD+BZ. These findings suggest that M. pruriens contains water-soluble ingredients that either have an intrinsic DDCI-like activity or mitigate the need for an add-on DDCI to ameliorate parkinsonism. These unique long-term anti-parkinsonian effects of a parenterally administered water extract of M. pruriens seed powder may provide a platform for future drug discoveries and novel treatment strategies in PD.

  17. A Water Extract of Mucuna pruriens Provides Long-Term Amelioration of Parkinsonism with Reduced Risk for Dyskinesias

    PubMed Central

    Lieu, Christopher A.; Kunselman, Allen R.; Manyam, Bala V.; Venkiteswaran, Kala; Subramanian, Thyagarajan

    2010-01-01

    Dopaminergic anti-parkinsonian medications, such as levodopa (LD) cause drug-induced dyskinesias (DID) in majority of patients with Parkinson's disease (PD). Mucuna pruriens, a legume extensively used in Ayurveda to treat PD, is reputed to provide anti-parkinsonian benefits without inducing DID. We compared the behavioral effects of chronic parenteral administration of a water extract of Mucuna pruriens seed powder (MPE) alone without any additives, MPE combined with the peripheral dopa-decarboxylase inhibitor (DDCI) benserazide (MPE+BZ), LD+BZ and LD alone without BZ in the hemiparkinsonian rat model of PD. A battery of behavioral tests assessed by blinded investigators served as outcome measures in these randomized trials. In experiment 1, animals that received LD+BZ or MPE+BZ at high (6mg/Kg) and medium (4mg/Kg) equivalent doses demonstrated significant alleviation of parkinsonism, but, developed severe dose-dependent DID. LD+BZ at low doses (2mg/Kg) did not provide significant alleviation of parkinsonism. In contrast, MPE+BZ at an equivalent low dose significantly ameliorated parkinsonism. In experiment 2, MPE without any additives (12mg/Kg and 20mg/Kg LD equivalent dose) alleviated parkinsonism with significantly less DID compared to LD+BZ or MPE+BZ. In experiment 3, MPE without additives administered chronically provided long-term anti-parkinsonian benefits without causing DID. In experiment 4, MPE alone provided significantly more behavioral benefit when compared to the equivalent dose of synthetic LD alone without BZ. In experiment 5, MPE alone reduced the severity of DID in animals initially primed with LD+BZ. These findings suggest that Mucuna pruriens contains water soluble ingredients that either have an intrinsic DDCI-like activity or mitigate the need for an add-on DDCI to ameliorate parkinsonism. These unique long-term antiparkinsonian effects of a parenterally administered water extract of Mucuna pruriens seed powder may provide a platform for future drug discoveries and novel treatment strategies in PD. PMID:20570206

  18. Impact of geometric uncertainties on dose calculations for intensity modulated radiation therapy of prostate cancer

    NASA Astrophysics Data System (ADS)

    Jiang, Runqing

    Intensity-modulated radiation therapy (IMRT) uses non-uniform beam intensities within a radiation field to provide patient-specific dose shaping, resulting in a dose distribution that conforms tightly to the planning target volume (PTV). Unavoidable geometric uncertainty arising from patient repositioning and internal organ motion can lead to lower conformality index (CI) during treatment delivery, a decrease in tumor control probability (TCP) and an increase in normal tissue complication probability (NTCP). The CI of the IMRT plan depends heavily on steep dose gradients between the PTV and organ at risk (OAR). Geometric uncertainties reduce the planned dose gradients and result in a less steep or "blurred" dose gradient. The blurred dose gradients can be maximized by constraining the dose objective function in the static IMRT plan or by reducing geometric uncertainty during treatment with corrective verification imaging. Internal organ motion and setup error were evaluated simultaneously for 118 individual patients with implanted fiducials and MV electronic portal imaging (EPI). A Gaussian probability density function (PDF) is reasonable for modeling geometric uncertainties as indicated by the 118 patients group. The Gaussian PDF is patient specific and group standard deviation (SD) should not be used for accurate treatment planning for individual patients. In addition, individual SD should not be determined or predicted from small imaging samples because of random nature of the fluctuations. Frequent verification imaging should be employed in situations where geometric uncertainties are expected. Cumulative PDF data can be used for re-planning to assess accuracy of delivered dose. Group data is useful for determining worst case discrepancy between planned and delivered dose. The margins for the PTV should ideally represent true geometric uncertainties. The measured geometric uncertainties were used in this thesis to assess PTV coverage, dose to OAR, equivalent uniform dose per fraction (EUDf) and NTCP. The dose distribution including geometric uncertainties was determined from integration of the convolution of the static dose gradient with the PDF. Integration of the convolution of the static dose and derivative of the PDF can also be used to determine the dose including geometric uncertainties although this method was not investigated in detail. Local maximum dose gradient (LMDG) was determined via optimization of dose objective function by manually adjusting DVH control points or selecting beam numbers and directions during IMRT treatment planning. Minimum SD (SDmin) is used when geometric uncertainty is corrected with verification imaging. Maximum SD (SDmax) is used when the geometric uncertainty is known to be large and difficult to manage. SDmax was 4.38 mm in anterior-posterior (AP) direction, 2.70 mm in left-right (LR) direction and 4.35 mm in superior-inferior (SI) direction; SDmin was 1.1 mm in all three directions if less than 2 mm threshold was used for uncorrected fractions in every direction. EUDf is a useful QA parameter for interpreting the biological impact of geometric uncertainties on the static dose distribution. The EUD f has been used as the basis for the time-course NTCP evaluation in the thesis. Relative NTCP values are useful for comparative QA checking by normalizing known complications (e.g. reported in the RTOG studies) to specific DVH control points. For prostate cancer patients, rectal complications were evaluated from specific RTOG clinical trials and detailed evaluation of the treatment techniques (e.g. dose prescription, DVH, number of beams, bean angles). Treatment plans that did not meet DVH constraints represented additional complication risk. Geometric uncertainties improved or worsened rectal NTCP depending on individual internal organ motion within patient.

  19. Initial assessment of image quality for low-dose PET: evaluation of lesion detectability

    NASA Astrophysics Data System (ADS)

    Schaefferkoetter, Joshua D.; Yan, Jianhua; Townsend, David W.; Conti, Maurizio

    2015-07-01

    In the context of investigating the potential of low-dose PET imaging for screening applications, we developed methods to assess small lesion detectability as a function of the number of counts in the scan. We present here our methods and preliminary validation using tuberculosis cases. FDG-PET data from seventeen patients presenting diffuse hyper-metabolic lung lesions were selected for the study, to include a wide range of lesion sizes and contrasts. Reduced doses were simulated by randomly discarding events in the PET list mode, and ten realizations at each simulated dose were generated and reconstructed. The data were grouped into 9 categories determined by the number of included true events, from  >40 M to  <250 k counts. The images reconstructed from the original full statistical set were used to identify lung lesions, and each was, at every simulated dose, quantified by 6 parameters: lesion metabolic volume, lesion-to-background contrast, mean lesion tracer uptake, standard deviation of activity measurements (across realizations), lesion signal-to-noise ratio (SNR), and Hotelling observer SNR. Additionally, a lesion-detection task including 550 images was presented to several experienced image readers for qualitative assessment. Human observer performances were ranked using receiver operating characteristic analysis. The observer results were correlated with the lesion image measurements and used to train mathematical observer models. Absolute sensitivities and specificities of the human observers, as well as the area under the ROC curve, showed clustering and performance similarities among images produced from 5 million or greater counts. The results presented here are from a clinically realistic but highly constrained experiment, and more work is needed to validate these findings with a larger patient population.

  20. Initial assessment of image quality for low-dose PET: evaluation of lesion detectability.

    PubMed

    Schaefferkoetter, Joshua D; Yan, Jianhua; Townsend, David W; Conti, Maurizio

    2015-07-21

    In the context of investigating the potential of low-dose PET imaging for screening applications, we developed methods to assess small lesion detectability as a function of the number of counts in the scan. We present here our methods and preliminary validation using tuberculosis cases. FDG-PET data from seventeen patients presenting diffuse hyper-metabolic lung lesions were selected for the study, to include a wide range of lesion sizes and contrasts. Reduced doses were simulated by randomly discarding events in the PET list mode, and ten realizations at each simulated dose were generated and reconstructed. The data were grouped into 9 categories determined by the number of included true events, from  >40 M to  <250 k counts. The images reconstructed from the original full statistical set were used to identify lung lesions, and each was, at every simulated dose, quantified by 6 parameters: lesion metabolic volume, lesion-to-background contrast, mean lesion tracer uptake, standard deviation of activity measurements (across realizations), lesion signal-to-noise ratio (SNR), and Hotelling observer SNR. Additionally, a lesion-detection task including 550 images was presented to several experienced image readers for qualitative assessment. Human observer performances were ranked using receiver operating characteristic analysis. The observer results were correlated with the lesion image measurements and used to train mathematical observer models. Absolute sensitivities and specificities of the human observers, as well as the area under the ROC curve, showed clustering and performance similarities among images produced from 5 million or greater counts. The results presented here are from a clinically realistic but highly constrained experiment, and more work is needed to validate these findings with a larger patient population.

  1. Pragmatic pharmacology: population pharmacokinetic analysis of fentanyl using remnant samples from children after cardiac surgery

    PubMed Central

    Van Driest, Sara L.; Marshall, Matthew D.; Hachey, Brian; Beck, Cole; Crum, Kim; Owen, Jill; Smith, Andrew H.; Kannankeril, Prince J.; Woodworth, Alison; Caprioli, Richard M.

    2016-01-01

    Aims One barrier contributing to the lack of pharmacokinetic (PK) data in paediatric populations is the need for serial sampling. Analysis of clinically obtained specimens and data may overcome this barrier. To add evidence for the feasibility of this approach, we sought to determine PK parameters for fentanyl in children after cardiac surgery using specimens and data generated in the course of clinical care, without collecting additional blood samples. Methods We measured fentanyl concentrations in plasma from leftover clinically‐obtained specimens in 130 paediatric cardiac surgery patients and successfully generated a PK dataset using drug dosing data extracted from electronic medical records. Using a population PK approach, we estimated PK parameters for this population, assessed model goodness‐of‐fit and internal model validation, and performed subset data analyses. Through simulation studies, we compared predicted fentanyl concentrations using model‐driven weight‐adjusted per kg vs. fixed per kg fentanyl dosing. Results Fentanyl clearance for a 6.4 kg child, the median weight in our cohort, is 5.7 l h–1 (2.2–9.2 l h–1), similar to values found in prior formal PK studies. Model assessment and subset analyses indicated the model adequately fit the data. Of the covariates studied, only weight significantly impacted fentanyl kinetics, but substantial inter‐individual variability remained. In simulation studies, model‐driven weight‐adjusted per kg fentanyl dosing led to more consistent therapeutic fentanyl concentrations than fixed per kg dosing. Conclusions We show here that population PK modelling using sparse remnant samples and electronic medical records data provides a powerful tool for assessment of drug kinetics and generation of individualized dosing regimens. PMID:26861166

  2. Assessment of the occupational exposure at a fertiliser industry in the northern part of Greece.

    PubMed

    Potiriadis, C; Koukouliou, V; Seferlis, S; Kehagia, K

    2011-03-01

    In the northern part of Greece, close to the city of Kavala, a phosphoric acid production industry has operated since 1965. The raw material used is the phosphate rock imported from the foreign countries. During industrial processes, naturally occurring radioactive materials (NORM) deposits exist in many facilities in the industry, causing increased levels of radiation exposure. Additionally, increased levels of NORM concentrations are also detected in the waste material of the production process, the phosphogypsum. According to the Greek Regulations for Radiation Protection (no. 216B, 5/3/2001), which is in accordance with the 96/29/EURATOM 31/5/1996, the action levels concerning the effective dose to workers at workplaces due to natural radiation sources are 1 mSv y(-1). Work activities where the corresponding doses exceed 6 mSv y(-1) are under the control of the Greek Atomic Energy Commission (GAEC). The mean yearly radon concentration action level at workplaces is 400 Bq m(-3), while the corresponding concentration limit is 3000 Bq m(-3), respectively. GAEC, according to its constitutional law, is the responsible organisation to enforce and to implement the law by means of in situ surveys and laboratory measurements. The first inspection of the area was performed in 2002 and the first measures were proposed. Periodic inspections were performed every 2 y in order to extend the operation licensing of the industry. In this work a dose assessment of the workers based on in situ and laboratory measurements is presented. In order to assess the doses to the workers the external and the internal doses are estimated.

  3. Lack of interaction between a new antihistamine, mizolastine, and lorazepam on psychomotor performance and memory in healthy volunteers.

    PubMed

    Patat, A; Perault, M C; Vandel, B; Ulliac, N; Zieleniuk, I; Rosenzweig, P

    1995-01-01

    1. The possible interaction between a new H1 antihistamine, mizolastine, and lorazepam was assessed in a randomised, double-blind, cross-over, placebo-controlled study involving 16 healthy young male volunteers who received mizolastine 10 mg or placebo once daily for 8 days with a 1 week wash-out interval. The interaction of mizolastine, at steady-state, with a single oral dose of lorazepam or placebo was assessed on days 6 or 8 of each treatment period. 2. Psychomotor performance and cognitive function were evaluated using objective tests (critical flicker fusion threshold, choice reaction time, tapping, arithmetic calculation, body sway) and self-ratings (visual analogue scale, ARCI) before and at 2, 4, 6 and 8 h after dosing. Short-term memory (Sternberg memory scanning immediate free recall of a word list) and long-term memory (delayed free recall and recognition of words and pictures) were assessed before and at 3 h after dosing. Pharmacodynamic interactions were evaluated by repeated measures ANOVA in a 2 x 2 factorial interaction model. 3. Mizolastine, 10 mg once daily, at steady-state, was devoid of sedation and detrimental effect on skilled performance and memory. 4. In contrast, a single 2 mg dose of lorazepam produced marked impairment of psychomotor performance, cognitive functions (significant reduction in flicker fusion threshold, tapping and arithmetic calculation and increase in reaction times and body sway) and subjective sedation from 2 to 8 h after dosing. In addition, lorazepam induced an anterograde amnesia, characterised by a decrease in delayed free recall and recognition, and a deficit in short term memory.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Skin autofluorescence reflects individual seasonal UV exposure, skin photodamage and skin cancer development in organ transplant recipients.

    PubMed

    Togsverd-Bo, Katrine; Philipsen, Peter Alshede; Hædersdal, Merete; Wulf, Hans Christian Olsen

    2018-01-01

    Ultraviolet radiation (UVR)-induced skin cancers varies among organ transplant recipients (OTRs). To improve individual risk assessment of skin cancer, objectively quantified skin photodamage is needed. We measured personal UVR-exposure dose in OTRs and assessed the relation between individual UVR exposure, skin cancer and objectively measured photodamage in terms of skin autofluorescence, pigmentation, and black light-evaluated solar lentigines. Danish OTRs with (n=15) and without a history of skin cancer (n=15) kept sun diaries from May to September and wore personal dosimeters recording time-stamped UVR doses in standard erythema doses (SED). Photodamage was quantified as skin autofluorescence with excitation at 370nm (F370) and 430nm (F430), skin pigmentation (pigment protection factor, PPF), and black light-evaluated solar lentigines. OTRs with skin cancer received a higher UVR dose than OTRs without skin cancer (median 116 SED vs. 67 SED, p=0.07) and UVR exposure doses were correlated with increased PPF (p=0.052) and F370 on the shoulder (F370 shoulder ) (p=0.04). We found that skin cancer was associated with F370 shoulder (OR 10.53, CI 3.3-31,938; p=0.018) and time since transplantation (OR 1.34, CI 0.95-1.91, p=0.097). A cut-off at 7.2 arbitrary units, 89% of OTRs with skin cancer had F370 shoulder values above 7.2 arbitrary units and F370 shoulder was additionally related to patient age (p=0.09) and black light-evaluated solar lentigines (p=0.04). F370 autofluorescence indicates objectively measured photodamage and may be used for individual risk assessment of skin cancer development in OTRs. Copyright © 2017. Published by Elsevier B.V.

  5. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study

    PubMed Central

    Mathieu, Kelsey B.; Ai, Hua; Fox, Patricia S.; Godoy, Myrna Cobos Barco; Munden, Reginald F.; de Groot, Patricia M.

    2014-01-01

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground‐glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model‐based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back‐projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast‐to‐noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening. PACS numbers: 87.57.Q‐, 87.57.nf PMID:24710436

  6. Single dose oral diclofenac for acute postoperative pain in adults

    PubMed Central

    Derry, Philip; Derry, Sheena; Moore, R Andrew; McQuay, Henry J

    2014-01-01

    Background Diclofenac is a non-steroidal anti-inflammatory drug (NSAID), available as a potassium salt (immediate-release) or sodium salt (delayed-release). This review updates an earlier review published in The Cochrane Database of Systematic Reviews (Issue 2, 2004) on ‘Single dose oral diclofenac for postoperative pain’. Objectives To assess single dose oral diclofenac for the treatment of acute postoperative pain. Search methods Cochrane CENTRAL, MEDLINE, EMBASE, Biological Abstracts, the Oxford Pain Relief Database, and reference lists of articles were searched; last search December 2008. Selection criteria Randomised, double-blind, placebo-controlled clinical trials of single dose, oral diclofenac (sodium or potassium) for acute postoperative pain in adults. Data collection and analysis Two review authors independently assessed studies for inclusion and quality, and extracted data. The area under the pain relief versus time curve was used to derive the proportion of participants with at least 50% pain relief over 4 to 6 hours, using validated equations. Relative benefit (risk) and number needed to treat to benefit (NNT) were calculated. Information on adverse events, time to remedication, and participants needing additional analgesia was also collected. Main results Fifteen studies (eight additional studies) with 1512 participants more than doubled the information available at each dose. Overall 50% to 60% of participants experienced at least 50% pain relief over 4 to 6 hours at any dose with diclofenac, compared to 10 to 20% with placebo, giving NNTs of about 2.5 for doses of 25 mg to 100 mg (similar to earlier review); no dose response was demonstrated. At 50 mg and 100 mg, NNTs for diclofenac potassium (2.1 (1.8 to 2.4) and 1.9 (1.7 to 2.2)) were significantly lower (better) than for diclofenac sodium (6.7 (4.2 to 17) and 4.5 (3.2 to 7.7)). The median time to use of rescue medication was 2 hours for placebo, 4.3 hours for diclofenac 50 mg and 4.9 hours for diclofenac 100 mg. Adverse events were reported at a similar rate to placebo, with no serious events. Authors’ conclusions Oral diclofenac is an effective single-dose treatment for moderate to severe postoperative pain. Significantly more participants experienced at least 50% pain relief over 4 to 6 hours with diclofenac potassium than with diclofenac sodium. There was no significant difference between diclofenac and placebo in the incidence of adverse events. PMID:19370609

  7. Chemotherapy options in elderly and frail patients with metastatic colorectal cancer (MRC FOCUS2): an open-label, randomised factorial trial.

    PubMed

    Seymour, Matthew T; Thompson, Lindsay C; Wasan, Harpreet S; Middleton, Gary; Brewster, Alison E; Shepherd, Stephen F; O'Mahony, M Sinead; Maughan, Timothy S; Parmar, Mahesh; Langley, Ruth E

    2011-05-21

    Elderly and frail patients with cancer, although often treated with chemotherapy, are under-represented in clinical trials. We designed FOCUS2 to investigate reduced-dose chemotherapy options and to seek objective predictors of outcome in frail patients with advanced colorectal cancer. We undertook an open, 2 × 2 factorial trial in 61 UK centres for patients with previously untreated advanced colorectal cancer who were considered unfit for full-dose chemotherapy. After comprehensive health assessment (CHA), patients were randomly assigned by minimisation to: 48-h intravenous fluorouracil with levofolinate (group A); oxaliplatin and fluorouracil (group B); capecitabine (group C); or oxaliplatin and capecitabine (group D). Treatment allocation was not masked. Starting doses were 80% of standard doses, with discretionary escalation to full dose after 6 weeks. The two primary outcome measures were: addition of oxaliplatin ([A vs B] + [C vs D]), assessed with progression-free survival (PFS); and substitution of fluorouracil with capecitabine ([A vs C] + [B vs D]), assessed by change from baseline to 12 weeks in global quality of life (QoL). Analysis was by intention to treat. Baseline clinical and CHA data were modelled against outcomes with a novel composite measure, overall treatment utility (OTU). This study is registered, number ISRCTN21221452. 459 patients were randomly assigned (115 to each of groups A-C, 114 to group D). Factorial comparison of addition of oxaliplatin versus no addition suggested some improvement in PFS, but the finding was not significant (median 5·8 months [IQR 3·3-7·5] vs 4·5 months [2·8-6·4]; hazard ratio 0·84, 95% CI 0·69-1·01, p=0·07). Replacement of fluorouracil with capecitabine did not improve global QoL: 69 of 124 (56%) patients receiving fluorouracil reported improvement in global QoL compared with 69 of 123 (56%) receiving capecitabine. The risk of having any grade 3 or worse toxic effect was not significantly increased with oxaliplatin (83/219 [38%] vs 70/221 [32%]; p=0·17), but was higher with capecitabine than with fluorouracil (88/222 [40%] vs 65/218 [30%]; p=0·03). In multivariable analysis, fewer baseline symptoms (odds ratio 1·32, 95% CI 1·14-1·52), less widespread disease (1·51, 1·05-2·19), and use of oxaliplatin (0·57, 0·39-0·82) were predictive of better OTU. FOCUS2 shows that with an appropriate design, including reduced starting doses of chemotherapy, frail and elderly patients can participate in a randomised controlled trial. On balance, a combination including oxaliplatin was preferable to single-agent fluoropyrimidines, although the primary endpoint of PFS was not met. Capecitabine did not improve QoL compared with fluorouracil. Comprehensive baseline assessment holds promise as an objective predictor of treatment benefit. Cancer Research UK and the Medical Research Council. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Systemic effects of low-dose dopamine during administration of cytarabine.

    PubMed

    Connelly, James; Benani, Dina J; Newman, Matthew; Burton, Bradley; Crow, Jessica; Levis, Mark

    2017-09-01

    Purpose Low-dose dopamine has been utilized to improve renal blood flow, urine output, and reduce drug-induced nephrotoxicity. The purpose of this study was to assess changes in renal function, cardiovascular adverse events, and neurologic toxicity in patients receiving cytarabine with or without low-dose dopamine. Methods A retrospective, single-center, cohort study of patients receiving cytarabine at 667 mg/m 2 /dose or greater, with or without dopamine at ≤5 mcg/kg/min. Cohorts were based upon initiation or absence of low-dose dopamine; cytarabine only, cytarabine + pre- and day of low-dose dopamine, and cytarabine + post-low-dose dopamine. Renal outcomes (urine output, serum creatinine, and creatinine clearance) were compared with baseline and between cohorts. Safety endpoints (arrhythmias, tachycardia, and neurotoxicity) were compared between cohorts based on low-dose dopamine exposure. Results There was no difference in urine output from baseline in all cohorts. Comparing cytarabine only and pre- and day of low-dose dopamine cohorts, there was no difference in urine output. In those receiving low-dose dopamine, there was no difference in serum creatinine and creatinine clearance from baseline. No arrhythmias were documented during the study period, and there was no difference in the incidence of tachycardia between groups (P = 0.66). Neurotoxicity was reported in three patients who were on low-dose dopamine. Conclusion Though variation existed in individual patients administered low-dose dopamine, the use of low-dose dopamine did not significantly impact renal function in this small sample at a single institution. In addition, low-dose dopamine did not negatively impact cardiovascular function.

  9. The susceptibility of TaO x-based memristors to high dose rate ionizing radiation and total ionizing dose

    DOE PAGES

    McLain, Michael Lee; Sheridan, Timothy J.; Hjalmarson, Harold Paul; ...

    2014-11-11

    This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaO x) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×10 7 rad(Si)/s to 4.7 ×10 8 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×10 8 rad(Si)/s. This is the first dose rate study on any type ofmore » memristive memory technology. In addition to assessing the tolerance of TaO x memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.« less

  10. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors.

    PubMed

    Baumstark, Annette; Jendrike, Nina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2017-10-01

    Self-monitoring of blood glucose (BG) is an essential part of diabetes therapy. Accurate and reliable results from BG monitoring systems (BGMS) are important especially when they are used to calculate insulin doses. This study aimed at assessing system accuracy of BGMS and possibly related insulin dosing errors. System accuracy of six different BGMS (Accu-Chek ® Aviva Nano, Accu-Chek Mobile, Accu-Chek Performa Nano, CONTOUR ® NEXT LINK 2.4, FreeStyle Lite, OneTouch ® Verio ® IQ) was assessed in comparison to a glucose oxidase and a hexokinase method. Study procedures and analysis were based on ISO 15197:2013/EN ISO 15197:2015, clause 6.3. In addition, insulin dosing error was modeled. In the comparison against the glucose oxidase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 14.3%/4.3%/0.3% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U and missing the modeled target by 20 mg/dL/40 mg/dL/60 mg/dL, respectively. Compared against the hexokinase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 25.0%/10.5%/3.2% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U, respectively. Differences in system accuracy were found, even among BGMS that fulfilled the minimum system accuracy criteria of ISO 15197:2013. In the error model, considerable insulin dosing errors resulted for some of the investigated systems. Diabetes patients on insulin therapy should be able to rely on their BGMS' readings; therefore, they require highly accurate BGMS, in particular, when making therapeutic decisions.

  11. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy?

    PubMed

    Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi

    2017-02-01

    Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.

  12. Effects of ethanol on cocaine self-administration in monkeys responding under a second-order schedule of reinforcement.

    PubMed

    John, William S; Nader, Michael A

    2017-01-01

    Concurrent alcohol use among cocaine abusers is common but the behavioral variables that promote co-abuse are not well understood. The present study examined the effects of intragastric (i.g.) ethanol (EtOH) administration in monkeys responding under a schedule of cocaine reinforcement in which extensive drug seeking was maintained by conditioned stimuli. Four adult male cynomolgus monkeys (Macaca fascicularis) were trained to respond under a second-order fixed-interval (FI) 600s (fixed-ratio (FR) 30:S) schedule of cocaine (0.003-0.56mg/kg/injection) presentation. Sessions ended after 5 injections or 90min had elapsed. Different EtOH doses (0.5-2.0g/kg, i.g.) were administered 30min before the session, typically on Tuesdays and Fridays. Blood ethanol concentrations (BECs) were also assessed. Pattern of FI responding was assessed by determining quarter-life (QL) values. Cocaine self-administration was characterized as an inverted U-shaped function of dose; QL values increased monotonically with dose. EtOH pretreatments dose-dependently decreased self-administration at several cocaine doses in 3 of 4 monkeys. In one animal, EtOH increased low-dose cocaine-maintained responding. For all monkeys, QL values were increased by EtOH when low- and high-cocaine doses were self-administered, suggesting additive effects of EtOH and cocaine. Furthermore, BECs were not altered following cocaine self-administration. The reductions in cocaine self-administration and the increases in QL values following EtOH, suggest that EtOH was enhancing cocaine-related conditioned reinforcement. A better understanding of the behavioral mechanisms that mediate the co-abuse of alcohol and cocaine will lead to improved treatments for both drugs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Use of Low-dose Aspirin as Secondary Prevention of Atherosclerotic Cardiovascular Disease Among US Adults (From the National Health Interview Survey, 2012)

    PubMed Central

    Fang, Jing; George, Mary G.; Gindi, Renee M.; Hong, Yuling; Yang, Quanhe; Ayala, Carma; Ward, Brian W.; Loustalot, Fleetwood

    2015-01-01

    Current guidelines recommend that adults with atherosclerotic cardiovascular disease take low-dose aspirin or other antiplatelet medications as secondary prevention of recurrent cardiovascular events. Yet, no national level assessment of low-dose aspirin use for secondary prevention of cardiovascular disease has been reported among a community-based population. Using data from the 2012 National Health Interview Survey, we assessed low-dose aspirin use among those with atherosclerotic cardiovascular disease. We estimated the prevalence ratios of low-dose aspirin use, adjusting for sociodemographic status, health insurance, and cardiovascular risk factors. Among those with atherosclerotic cardiovascular disease (n=3,068), 76% had been instructed to take aspirin, and 88% of those were following this advice. Of those not advised, 11% took aspirin on this own. Overall, 70% were taking aspirin (including those who followed their health care provider's advice and those who were not advised but took aspirin on their own). Logistic regression models showed that women, non-Hispanic blacks and Hispanics, those aged 40–64 years, with a high school education or with some college, or with fewer cardiovascular disease risk factors were less likely to take aspirin than men, non-Hispanic whites, those aged ≥65 years, with a college education or higher, or with all four selected cardiovascular disease risk factors, respectively. Additional analyses conducted among those with coronary heart disease only (n=2,007) showed similar patterns. In conclusion, use of low-dose aspirin for secondary prevention was 70%, with high reported adherence to health care providers' advice to take low-dose aspirin (88%), and significant variability within subgroups. PMID:25670639

  14. Linear-No-Threshold Default Assumptions for Noncancer and Nongenotoxic Cancer Risks: A Mathematical and Biological Critique.

    PubMed

    Bogen, Kenneth T

    2016-03-01

    To improve U.S. Environmental Protection Agency (EPA) dose-response (DR) assessments for noncarcinogens and for nonlinear mode of action (MOA) carcinogens, the 2009 NRC Science and Decisions Panel recommended that the adjustment-factor approach traditionally applied to these endpoints should be replaced by a new default assumption that both endpoints have linear-no-threshold (LNT) population-wide DR relationships. The panel claimed this new approach is warranted because population DR is LNT when any new dose adds to a background dose that explains background levels of risk, and/or when there is substantial interindividual heterogeneity in susceptibility in the exposed human population. Mathematically, however, the first claim is either false or effectively meaningless and the second claim is false. Any dose-and population-response relationship that is statistically consistent with an LNT relationship may instead be an additive mixture of just two quasi-threshold DR relationships, which jointly exhibit low-dose S-shaped, quasi-threshold nonlinearity just below the lower end of the observed "linear" dose range. In this case, LNT extrapolation would necessarily overestimate increased risk by increasingly large relative magnitudes at diminishing values of above-background dose. The fact that chemically-induced apoptotic cell death occurs by unambiguously nonlinear, quasi-threshold DR mechanisms is apparent from recent data concerning this quintessential toxicity endpoint. The 2009 NRC Science and Decisions Panel claims and recommendations that default LNT assumptions be applied to DR assessment for noncarcinogens and nonlinear MOA carcinogens are therefore not justified either mathematically or biologically. © 2015 The Author. Risk Analysis published by Wiley Periodicals, Inc. on behalf of Society for Risk Analysis.

  15. Collaborative work on evaluation of ovarian toxicity. 13) Two- or four-week repeated dose studies and fertility study of PPAR alpha/gamma dual agonist in female rats.

    PubMed

    Sato, Norihiro; Uchida, Keisuke; Nakajima, Mikio; Watanabe, Atsushi; Kohira, Terutomo

    2009-01-01

    The main focus of this study was to determine the optimal dosing period in a repeated dose toxicity study based on toxic effects as assessed by ovarian morphological changes. To assess morphological and functional changes induced in the ovary by a peroxisome proliferator-activated receptor (PPAR) alpha/gamma dual agonist, the compound was administered to female rats at dose levels of 0, 4, 20, and 100 mg/kg/day in a repeated dose toxicity study for 2 or 4 weeks, and from 2 weeks prior to mating to Day 7 of pregnancy in a female fertility study. In the repeated dose toxicity study, an increase in atresia of large follicles, a decrease in corpora lutea, and an increase in stromal cells were observed in the treated groups. In addition, the granulosa cell exfoliations into antrum of large follicles and corpora lutea with retained oocyte are morphological characteristics induced by this compound, and they might be related with abnormal condition of ovulation. In the female fertility study, the pregnancy rate tended to decrease in the 100 mg/kg/day group. At necropsy, decreases in the number of corpora lutea, implantations and live embryos were noted in the 20 and 100 mg/kg/day group. No changes were observed in animals given 4 mg/kg/day. These findings indicated that histopathological changes in the ovary are important endpoints for evaluation of drugs inducing ovarian damage. In conclusion, a 2-week administration period is sufficient to detect ovarian toxicity of this test compound in the repeated dose toxicity study.

  16. SU-F-T-323: A Post-Mastectomy Radiation Therapy Dose Distribution Study Using Nanodots and Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian, X; Vaidya, K; Puckett, L

    Purpose: In post-mastectomy radiation therapy (RT), skin dose must be accurately estimated to assess skin reactions such as erythema, desquamation and necrosis. Planning systems cannot always provide accurate dosimetry for target volumes distal to skin. Therefore, in-vivo dosimetry is necessary. A female anthropomorphic phantom was used with optically stimulated luminescence dosimeters (nanoDots) to measure dose to chest wall skin. In addition, EBT2 films was employed to measure dose to left lung and heart in post-mastectomy RT. Methods: Films and nanoDots were calibrated under full buildup conditions at 100cm SAD for 6MV photons. Five pieces of films were placed between slabsmore » of Rando phantom to assess dose to left lung and heart. Two layers of 0.5cm thick bolus were used to cover the whole left chest. Six pairs of nanoDots were placed at medical and lateral aspects on the bolus surface, between the 0.5cm bolus layers, and under the bolus. Three control nanoDots were placed on chest wall to quantify imaging dose. The phantom was CT scanned with all dosimeters in place, and treatment planning was performed with tangential fields (200cGy). All dosimeters were contoured on CT and dose was extracted. NanoDots were read using nanoDot reader and films were scanned using film scanner. The measured and calculated doses were tabulated. Results: Dose to 12 nanoDots were evaluated. Dose variance for surface nanoDots were +3.8%, +2.7%, −5% and −9.8%. Those at lateral positions, with greater beam obliquity had larger variance than the medial positions. A similar trend was observed for other nanoDots (Table1). Point doses from films for heart and the left lung were 112.7cGy and 108.7cGy, with +10.2% and +9.04% deviation from calculated values, respectively. Conclusion: Dosimetry provided by the advanced planning system was verified using NanoDots and films. Both nanoDots and films provided good estimation of dose distribution in post-mastectomy RT.« less

  17. New thermoluminescence age estimates for the Nyos maar eruption (Cameroon Volcanic Line)

    PubMed Central

    Tchouankoue, Jean Pierre; Nkouamen Nemzoue, Peguy Noel; Ayaba, Félicité; Nformidah-Ndah, Siggy Signe; Nformi Chifu, Emmanuel

    2017-01-01

    Nyos maar is located in the Cameroon Volcanic Line and generates a multitude of primary and secondary hazards to the local population. For risk assessment and hazard mitigation, the age of the Nyos maar eruption provides some vital information. Since previous dating efforts using a range of techniques resulted in vastly varying eruption ages, we applied thermoluminescence (TL) methods to obtain independent and direct chronological constraints for the time of maar formation. Target minerals were granitic quartz clasts contained in pyroclastic surge deposits. Thermoluminescence plateau results prove that heat and/or pressure during the phreatomagmatic eruption was sufficient to reset the inherited luminescence signal of granitic bedrock quartz. Parallel application of three TL measurement protocols to one of the two samples gave consistent equivalent doses for the quartz ultra-violet emission. Despite the robustness of our dose estimates, the assessment of the dose rate was accompanied by methodological challenges, such as estimation of the original size distribution of quartz grains in the pyroclastic deposits. Considering results from additional laboratory analyses to constrain these uncertainties, we calculate an average maximum TL age of 12.3 ± 1.5 ka for the Nyos maar eruption. Based on these new data, a more solid risk assessment can be envisaged. PMID:28558057

  18. New thermoluminescence age estimates for the Nyos maar eruption (Cameroon Volcanic Line).

    PubMed

    Schmidt, Christoph; Tchouankoue, Jean Pierre; Nkouamen Nemzoue, Peguy Noel; Ayaba, Félicité; Nformidah-Ndah, Siggy Signe; Nformi Chifu, Emmanuel

    2017-01-01

    Nyos maar is located in the Cameroon Volcanic Line and generates a multitude of primary and secondary hazards to the local population. For risk assessment and hazard mitigation, the age of the Nyos maar eruption provides some vital information. Since previous dating efforts using a range of techniques resulted in vastly varying eruption ages, we applied thermoluminescence (TL) methods to obtain independent and direct chronological constraints for the time of maar formation. Target minerals were granitic quartz clasts contained in pyroclastic surge deposits. Thermoluminescence plateau results prove that heat and/or pressure during the phreatomagmatic eruption was sufficient to reset the inherited luminescence signal of granitic bedrock quartz. Parallel application of three TL measurement protocols to one of the two samples gave consistent equivalent doses for the quartz ultra-violet emission. Despite the robustness of our dose estimates, the assessment of the dose rate was accompanied by methodological challenges, such as estimation of the original size distribution of quartz grains in the pyroclastic deposits. Considering results from additional laboratory analyses to constrain these uncertainties, we calculate an average maximum TL age of 12.3 ± 1.5 ka for the Nyos maar eruption. Based on these new data, a more solid risk assessment can be envisaged.

  19. Immunogenicity to poliovirus type 2 following two doses of fractional intradermal inactivated poliovirus vaccine: A novel dose sparing immunization schedule.

    PubMed

    Anand, Abhijeet; Molodecky, Natalie A; Pallansch, Mark A; Sutter, Roland W

    2017-05-19

    The polio eradication endgame strategic plan calls for the sequential removal of Sabin poliovirus serotypes from the trivalent oral poliovirus vaccine (tOPV), starting with type 2, and the introduction of ≥1 dose of inactivated poliovirus vaccine (IPV), to maintain an immunity base against poliovirus type 2. The global removal of oral poliovirus type 2 was successfully implemented in May 2016. However, IPV supply constraints has prevented introduction in 21 countries and led to complete stock-out in >20 countries. We conducted a literature review and contacted corresponding authors of recent studies with fractional-dose IPV (fIPV), one-fifth of intramuscular dose administered intradermally, to conduct additional type 2 immunogenicity analyses of two fIPV doses compared with one full-dose IPV. Four studies were identified that assessed immunogenicity of two fIPV doses compared to one full-dose IPV. Two fractional doses are more immunogenic than 1 full-dose, with type 2 seroconversion rates improving between absolute 19-42% (median: 37%, p<0.001) and relative increase of 53-125% (median: 82%), and antibody titer to type 2 increasing by 2-32-fold (median: 10-fold). Early age of administration and shorter intervals between doses were associated with lower immunogenicity. Overall, two fIPV doses are more immunogenic than a single full-dose, associated with significantly increased seroconversion rates and antibody titers. Two fIPV doses together use two-fifth of the vaccine compared to one full-dose IPV. In response to the current IPV shortage, a schedule of two fIPV doses at ages 6 and 14weekshas been endorsed by technical oversight committees and has been introduced in some affected countries. Copyright © 2017. Published by Elsevier Ltd.

  20. Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer.

    PubMed

    Eisbruch, Avraham; Ship, Jonathan A; Dawson, Laura A; Kim, Hyungjin M; Bradford, Carol R; Terrell, Jeffrey E; Chepeha, Douglas B; Teknos, Theodore N; Hogikyan, Norman D; Anzai, Yoshimi; Marsh, Lon H; Ten Haken, Randall K; Wolf, Gregory T

    2003-07-01

    The goals of this study were to facilitate sparing of the major salivary glands while adequately treating tumor targets in patients requiring comprehensive bilateral neck irradiation (RT), and to assess the potential for improved xerostomia. Since 1994 techniques of target irradiation and locoregional tumor control with conformal and intensity modulated radiation therapy (IMRT) have been developed. In patients treated with these modalities, the salivary flow rates before and periodically after RT have been measured selectively from each major salivary gland and the residual flows correlated with glands' dose volume histograms (DVHs). In addition, subjective xerostomia questionnaires have been developed and validated. The pattern of locoregional recurrence has been examined from computed tomography (CT) scans at the time of recurrence, transferring the recurrence volumes to the planning CT scans, and regenerating the dose distributions at the recurrence sites. Treatment plans for target coverage and dose homogeneity using static, multisegmental IMRT were found to be significantly better than standard RT plans. In addition, significant parotid gland sparing was achieved in the conformal plans. The relationships among dose, irradiated volume, and the residual saliva flow rates from the parotid glands were characterized by dose and volume thresholds. A mean radiation dose of 26 Gy was found to be the threshold for preserved stimulated saliva flow. Xerostomia questionnaire scores suggested that xerostomia was significantly reduced in patients irradiated with bilateral neck, parotid-sparing RT, compared to patients with similar tumors treated with standard RT. Examination of locoregional tumor recurrence patterns revealed that the large majority of recurrences occurred inside targets, in areas that had been judged to be at high risk and that had received RT doses according to the perceived risk. Tangible gains in salivary gland sparing and target coverage are being achieved, and an improvement in some measures of quality of life is suggested by our findings. Additional reduction of xerostomia may be achieved by further sparing of the salivary glands and the non-involved oral cavity. A mean parotid gland dose of < or = 26 Gy should be a planning objective if significant parotid function preservation is desired. The pattern of recurrence suggests that careful escalation of the dose to areas judged to be at highest risk may improve tumor control.

  1. Assessment of PLGA-PEG-PLGA Copolymer Hydrogel for Sustained Drug Delivery in the Ear

    PubMed Central

    Feng, Liang; Ward, Jonette A.; Li, S. Kevin; Tolia, Gaurav; Hao, Jinsong; Choo, Daniel I.

    2014-01-01

    Temperature sensitive copolymer systems were previously studied using modified diffusion cells in vitro for intratympanic injection, and the PLGA-PEG-PLGA copolymer systems were found to provide sustained drug delivery for several days. The objectives of the present study were to assess the safety of PLGA-PEG-PLGA copolymers in intratympanic injection in guinea pigs in vivo and to determine the effects of additives glycerol and poloxamer in PLGA-PEG-PLGA upon drug release in the diffusion cells in vitro for sustained inner ear drug delivery. In the experiments, the safety of PLGA-PEG-PLGA copolymers to inner ear was evaluated using auditory brainstem response (ABR). The effects of the additives upon drug release from PLGA-PEG-PLGA hydrogel were investigated in the modified Franz diffusion cells in vitro with cidofovir as the model drug. The phase transition temperatures of the PLGA-PEG-PLGA copolymers in the presence of the additives were also determined. In the ABR safety study, the PLGA-PEG-PLGA copolymer alone did not affect hearing when delivered at 0.05-mL dose but caused hearing loss after 0.1-mL injection. In the drug release study, the incorporation of the bioadhesive additive, poloxamer, in the PLGA-PEG-PLGA formulations was found to decrease the rate of drug release whereas the increase in the concentration of the humectant additive, glycerol, provided the opposite effect. In summary, the PLGA-PEG-PLGA copolymer did not show toxicity to the inner ear at the 0.05-mL dose and could provide sustained release that could be controlled by using the additives for inner ear applications. PMID:24438444

  2. Development of probabilistic internal dosimetry computer code

    NASA Astrophysics Data System (ADS)

    Noh, Siwan; Kwon, Tae-Eun; Lee, Jai-Ki

    2017-02-01

    Internal radiation dose assessment involves biokinetic models, the corresponding parameters, measured data, and many assumptions. Every component considered in the internal dose assessment has its own uncertainty, which is propagated in the intake activity and internal dose estimates. For research or scientific purposes, and for retrospective dose reconstruction for accident scenarios occurring in workplaces having a large quantity of unsealed radionuclides, such as nuclear power plants, nuclear fuel cycle facilities, and facilities in which nuclear medicine is practiced, a quantitative uncertainty assessment of the internal dose is often required. However, no calculation tools or computer codes that incorporate all the relevant processes and their corresponding uncertainties, i.e., from the measured data to the committed dose, are available. Thus, the objective of the present study is to develop an integrated probabilistic internal-dose-assessment computer code. First, the uncertainty components in internal dosimetry are identified, and quantitative uncertainty data are collected. Then, an uncertainty database is established for each component. In order to propagate these uncertainties in an internal dose assessment, a probabilistic internal-dose-assessment system that employs the Bayesian and Monte Carlo methods. Based on the developed system, we developed a probabilistic internal-dose-assessment code by using MATLAB so as to estimate the dose distributions from the measured data with uncertainty. Using the developed code, we calculated the internal dose distribution and statistical values ( e.g. the 2.5th, 5th, median, 95th, and 97.5th percentiles) for three sample scenarios. On the basis of the distributions, we performed a sensitivity analysis to determine the influence of each component on the resulting dose in order to identify the major component of the uncertainty in a bioassay. The results of this study can be applied to various situations. In cases of severe internal exposure, the causation probability of a deterministic health effect can be derived from the dose distribution, and a high statistical value ( e.g., the 95th percentile of the distribution) can be used to determine the appropriate intervention. The distribution-based sensitivity analysis can also be used to quantify the contribution of each factor to the dose uncertainty, which is essential information for reducing and optimizing the uncertainty in the internal dose assessment. Therefore, the present study can contribute to retrospective dose assessment for accidental internal exposure scenarios, as well as to internal dose monitoring optimization and uncertainty reduction.

  3. Assessments of Voice Use and Voice Quality Among College/University Singing Students Ages 18-24 Through Ambulatory Monitoring With a Full Accelerometer Signal.

    PubMed

    Schloneger, Matthew J; Hunter, Eric J

    2017-01-01

    The multiple social and performance demands placed on college/university singers could put their still-developing voices at risk. Previous ambulatory monitoring studies have analyzed the duration, intensity, and frequency (in Hertz) of voice use among such students. Nevertheless, no studies to date have incorporated the simultaneous acoustic voice quality measures into the acquisition of these measures to allow for direct comparison during the same voicing period. Such data could provide greater insight into how young singers use their voices, as well as identify potential correlations between vocal dose and acoustic changes in voice quality. The purpose of this study was to assess the voice use and the estimated voice quality of college/university singing students (18-24 years old, N = 19). Ambulatory monitoring was conducted over three full, consecutive weekdays measuring voice from an unprocessed accelerometer signal measured at the neck. From this signal, traditional vocal dose metrics such as phonation percentage, dose time, cycle dose, and distance dose were analyzed. Additional acoustic measures included perceived pitch, pitch strength, long-term average spectrum slope, alpha ratio, dB sound pressure level 1-3 kHz, and harmonic-to-noise ratio. Major findings from more than 800 hours of recording indicated that among these students (a) higher vocal doses correlated significantly with greater voice intensity, more vocal clarity and less perturbation; and (b) there were significant differences in some acoustic voice quality metrics between nonsinging, solo singing, and choral singing. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  4. The NUTRAOLEOUM Study, a randomized controlled trial, for achieving nutritional added value for olive oils.

    PubMed

    Biel, Sara; Mesa, Maria-Dolores; de la Torre, Rafael; Espejo, Juan-Antonio; Fernández-Navarro, Jose-Ramón; Fitó, Montserrat; Sánchez-Rodriguez, Estefanía; Rosa, Carmen; Marchal, Rosa; Alche, Juan de Dios; Expósito, Manuela; Brenes, Manuel; Gandul, Beatriz; Calleja, Miguel Angel; Covas, María-Isabel

    2016-10-22

    Virgin olive oil, a recognized healthy food, cannot be consumed in great quantities. We aim to assess in humans whether an optimized virgin olive oil with high phenolic content (OVOO, 429 mg/Kg) and a functional one (FOO), both rich in phenolic compounds (429 mg/Kg) and triterpenic acids (389 mg/kg), could provide health benefits additional to those supplied a by a standard virgin olive oil (VOO). A randomized, double-blind, crossover, controlled study will be conducted. Healthy volunteers (aged 20 to 50) will be randomized into one of three groups of daily raw olive oil consumption: VOO, OVOO, and FOO (30 mL/d). Olive oils will be administered over 3-week periods preceded by 2-week washout ones. The main outcomes will be markers of lipid and DNA oxidation, inflammation, and vascular damage. A bioavailability and dose-response study will be nested within this sustained- consumption one. It will be made up of 18 volunteers and be performed at two stages after a single dose of each olive oil. Endothelial function and nitric oxide will be assessed at baseline and at 4 h and 6 h after olive oil single dose ingestion. For the first time the NUTRAOLEUM Study will provide first level evidence on the health benefits in vivo in humans of olive oil triterpenes (oleanolic and maslinic acid) in addition to their bioavailability and disposition. The Trial has been registered in ClinicalTrials.gov ID: NCT02520739 .

  5. Nitrates for stable angina: a systematic review and meta-analysis of randomized clinical trials.

    PubMed

    Wei, Jiafu; Wu, Taixiang; Yang, Qing; Chen, Mao; Ni, Juan; Huang, Dejia

    2011-01-07

    To assess the effect (harms and benefits) of nitrates for stable angina. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. Randomized controlled trials with both parallel and crossover design were included. The following outcome measures were evaluated: number of angina attacks weekly and nitroglycerin consumption, quality of life, total exercise duration, time to onset of angina and time to 1 mm ST depression. Fifty-one trials with 3595 patients meeting inclusion criteria were analyzed. Both intermittent and continuous regimens of nitrates lengthened exercise duration significantly by 31 and 53 s respectively. The number of angina attacks was significantly reduced by 2.89 episodes weekly for continuous administration and 1.5 episodes weekly for intermittent administration. With intermittent administration, increased dose provided with 21 s more length of exercise duration. With continuous administration, exercise duration was pronged more in low-dose group. Quality of life was not improved by continuous application of GTN patches and was similar between continuous and intermittent groups. In addition, 51.6% patients receiving nitrates complained with headache. Long-term administration of nitrates was beneficial for angina prophylaxis and improved exercise performance but might be ineffective for improving quality of life. With continuous regimen, low-dose nitrates were more effective than high-dose ones for improving exercise performance. By contrast, with intermittent regimen, high-dose nitrates were more effective. In addition, intermittent administration could bring zero-hour effect. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  6. Toxicological studies on palytoxin and ostreocin-D administered to mice by three different routes.

    PubMed

    Ito, Emiko; Yasumoto, Takeshi

    2009-09-01

    Palytoxin (PLT) first isolated from zoanthids is extremely lethal to animals by intraperitoneal or intravenous administration but shows little toxicity by gavage dosing in contradiction to the occurrence of fatal poisoning due to PLT-containing seafood. In order to fully elucidate its potential risks to human we evaluated the toxicological effects via three ways of dosing: gavage, intra-tracheal administration (IT) and sublingual administration. A new analog, 42-hydroxy-3,26-didemethyl-19,44-dideoxypalytoxin isolated from the dinoflagellate Ostreopsis siamensis and named ostreocin-D (OSD), was also used for comparison, additionally conducted by i.p. By gavage dosing, both toxins did not produce death in mice at the maximum dosage of 200 microg/kg of PLT and 300 microg/kg of OSD. Addition of dietary lipid components to PLT solutions for gavage or use of ulcerated mice did not alter the results, indicating no enhancement of PLT absorption. The two toxins were most toxic by the IT route, causing bleeding and alveolar destruction in the lung and resultant death at 2 microg/kg of PLT, and 11 microg/kg of OSD. Both toxins also induced organ injuries after 24h when dosed by sublingual administration at about 200 microg/kg. The injuries became fatal when PLT was dosed 2 or 3 times. The results pointed to the necessity of taking multiple approaches to assess the potential health risks due to PLT and its analogs in food and environments.

  7. Safety and pharmacokinetics of the oral iron chelator SP-420 in β-thalassemia.

    PubMed

    Taher, Ali T; Saliba, Antoine N; Kuo, Kevin H; Giardina, Patricia J; Cohen, Alan R; Neufeld, Ellis J; Aydinok, Yesim; Kwiatkowski, Janet L; Jeglinski, Brenda I; Pietropaolo, Keith; Berk, Gregory; Viprakasit, Vip

    2017-12-01

    Our phase I, open-label, multi-center, dose-escalation study evaluated the pharmacokinetics (PK) of SP-420, a tridentate oral iron chelating agent of the desferrithiocin class, in patients with transfusion dependent β-thalassemia. SP-420 was administered as a single dose of 1.5 (n = 3), 3 (n = 3), 6 (n = 3), 12 (n = 3), and 24 (n = 6) mg/kg or as a twice-daily dose of 9 mg/kg (n = 6) over 14-28 days. There was a near dose-linear increase in the mean plasma SP-420 concentrations and in the mean values for C max and AUC 0-τ over the dose range evaluated. The median t max ranged from 0.5 to 2.25 h and was not dose dependent. The study was prematurely terminated by the sponsor due to renal adverse events (AE) including proteinuria, increase in serum creatinine, and one case of Fanconi syndrome. Other adverse effects included hypersensitivity reactions and gastrointestinal disturbances. Based on current dose administration, the renal AE observed outweighed the possible benefits from chelation therapy. However, additional studies assessing efficacy and safety of lower doses or less frequent dosing of SP-420 over longer durations with close monitoring would be necessary to better explain the findings of our study and characterize the safety of the study drug. © 2017 Wiley Periodicals, Inc.

  8. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases.

    PubMed

    Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F

    2016-05-01

    To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Myocardial perfusion imaging with PET

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S; Alexanderson, Erick; Slomka, Piotr

    2013-01-01

    PET-myocardial perfusion imaging (MPI) allows accurate measurement of myocardial perfusion, absolute myocardial blood flow and function at stress and rest in a single study session performed in approximately 30 min. Various PET tracers are available for MPI, and rubidium-82 or nitrogen-13-ammonia is most commonly used. In addition, a new fluorine-18-based PET-MPI tracer is currently being evaluated. Relative quantification of PET perfusion images shows very high diagnostic accuracy for detection of obstructive coronary artery disease. Dynamic myocardial blood flow analysis has demonstrated additional prognostic value beyond relative perfusion imaging. Patient radiation dose can be reduced and image quality can be improved with latest advances in PET/CT equipment. Simultaneous assessment of both anatomy and perfusion by hybrid PET/CT can result in improved diagnostic accuracy. Compared with SPECT-MPI, PET-MPI provides higher diagnostic accuracy, using lower radiation doses during a shorter examination time period for the detection of coronary artery disease. PMID:23671459

  10. MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER.

    PubMed

    Chiriotti, S; Parisi, A; Vanhavere, F; De Saint-Hubert, M; Vandevoorde, C; Slabbert, J; Beukes, P; de Kock, E; Symons, J

    2018-04-13

    Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

  11. Intratumoral Epidermal Growth Factor Receptor Antisense DNA Therapy in Head and Neck Cancer: First Human Application and Potential Antitumor Mechanisms

    PubMed Central

    Lai, Stephen Y.; Koppikar, Priya; Thomas, Sufi M.; Childs, Erin E.; Egloff, Ann Marie; Seethala, Raja R.; Branstetter, Barton F.; Gooding, William E.; Muthukrishnan, Ashok; Mountz, James M.; Lui, Vivian W.Y.; Shin, Dong M.; Agarwala, Sanjiv S.; Johnson, Rita; Couture, Larry A.; Myers, Eugene N.; Johnson, Jonas T.; Mills, Gordon; Argiris, Athanassios; Grandis, Jennifer R.

    2009-01-01

    Purpose Squamous cell carcinoma of the head and neck (SCCHN) is characterized by upregulation of the epidermal growth factor receptor (EGFR). We developed a novel strategy to target EGFR by using a therapeutic gene that consisted of an EGFR antisense (AS) gene sequence under U6 promoter control. A phase I clinical trial was conducted to evaluate the safety and biologic effects of EGFR AS. Patients and Methods Patients with advanced SCCHN who were refractory to standard therapies and who had at least one assessable and accessible lesion were enrolled. The EGFR AS dose was escalated in successive cohorts (six dose levels; 60 to 1,920 μg/injection). Patients received four weekly intratumoral EGFR AS injections. Tumor biopsies were performed before and after completion of therapy. Treatment response was assessed by tumor volume measurements (positron emission tomography/computed tomography), and levels of target proteins were assessed by immunohistochemistry. Results Seventeen assessable patients were treated. No grades 3 to 4 or dose-limiting toxicities were noted, and a maximum-tolerated dose was not reached. Five patients (29%) achieved a clinical response, which included two complete responses (CRs) and three partial responses (PRs); two additional patients had stable disease (SD) as the best response. Patients with disease control (CR + PR + SD) had tumors with higher EGFR and lower STAT3 expression at baseline compared with patients who had progressive disease (P = .0312 and P = .095, respectively). Conclusion Intratumoral EGFR AS was safe and resulted in antitumor activity in patients with advanced SCCHN. Baseline levels of high EGFR and low STAT3 may be associated with antitumor effects. PMID:19204206

  12. Probalistic Assessment of Radiation Risk for Solar Particle Events

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Cucinotta, Francis A.

    2008-01-01

    For long duration missions outside of the protection of the Earth's magnetic field, exposure to solar particle events (SPEs) is a major safety concern for crew members during extra-vehicular activities (EVAs) on the lunar surface or Earth-to-moon or Earth-to-Mars transit. The large majority (90%) of SPEs have small or no health consequences because the doses are low and the particles do not penetrate to organ depths. However, there is an operational challenge to respond to events of unknown size and duration. We have developed a probabilistic approach to SPE risk assessment in support of mission design and operational planning. Using the historical database of proton measurements during the past 5 solar cycles, the functional form of hazard function of SPE occurrence per cycle was found for nonhomogeneous Poisson model. A typical hazard function was defined as a function of time within a non-specific future solar cycle of 4000 days duration. Distributions of particle fluences for a specified mission period were simulated ranging from its 5th to 95th percentile. Organ doses from large SPEs were assessed using NASA's Baryon transport model, BRYNTRN. The SPE risk was analyzed with the organ dose distribution for the given particle fluences during a mission period. In addition to the total particle fluences of SPEs, the detailed energy spectra of protons, especially at high energy levels, were recognized as extremely important for assessing the cancer risk associated with energetic particles for large events. The probability of exceeding the NASA 30-day limit of blood forming organ (BFO) dose inside a typical spacecraft was calculated for various SPE sizes. This probabilistic approach to SPE protection will be combined with a probabilistic approach to the radiobiological factors that contribute to the uncertainties in projecting cancer risks in future work.

  13. A low-dose, dual-phase cardiovascular CT protocol to assess left atrial appendage anatomy and exclude thrombus prior to left atrial intervention.

    PubMed

    Lazoura, Olga; Ismail, Tevfik F; Pavitt, Christopher; Lindsay, Alistair; Sriharan, Mona; Rubens, Michael; Padley, Simon; Duncan, Alison; Wong, Tom; Nicol, Edward

    2016-02-01

    Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.

  14. TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, M; Cagnon, C; Sepahdari, A

    Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv andmore » above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement in patient management. Dr. McNitt-Gray’s disclosures: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less

  15. Radiation protection issues in galactic cosmic ray risk assessment

    NASA Technical Reports Server (NTRS)

    Sinclair, W. K.

    1994-01-01

    Radiation protection involves the limitation of exposure to below threshold doses for direct (or deterministic) effects and a knowledge of the risk of stochastic effects after low doses. The principal stochastic risk associated with low dose rate galactic cosmic rays is the increased risk of cancer. Estimates of this risk depend on two factors (a) estimates of cancer risk for low-LET radiation and (b) values of the appropriate radiation weighting factors, WR, for the high-LET radiations of galactic cosmic rays. Both factors are subject to considerable uncertainty. The low-LET cancer risk derived from the late effects of the atomic bombs is vulnerable to a number of uncertainties including especially that from projection in time, and from extrapolation from high to low dose rate. Nevertheless, recent low dose studies of workers and others tend to confirm these estimates. WR, relies on biological effects studied mainly in non-human systems. Additional laboratory studies could reduce the uncertainties in WR and thus produce a more confident estimate of the overall risk of galactic cosmic rays.

  16. Radiation protection issues in galactic cosmic ray risk assessment.

    PubMed

    Sinclair, W K

    1994-01-01

    Radiation protection involves the limitation of exposure to below threshold doses for direct (or deterministic) effects and a knowledge of the risk of stochastic effects after low doses. The principal stochastic risk associated with low dose rate galactic cosmic rays is the increased risk of cancer. Estimates of this risk depend on two factors (a) estimates of cancer risk for low-LET radiation and (b) values of the appropriate radiation weighting factors, WR, for the high-LET radiations of galactic cosmic rays. Both factors are subject to considerable uncertainty. The low-LET cancer risk derived from the late effects of the atomic bombs is vulnerable to a number of uncertainties including especially that from projection in time, and from extrapolation from high to low dose rate. Nevertheless, recent low dose studies of workers and others tend to confirm these estimates. WR, relies on biological effects studied mainly in non-human systems. Additional laboratory studies could reduce the uncertainties in WR and thus produce a more confident estimate of the overall risk of galactic cosmic rays.

  17. Paracetamol/acetaminophen (single administration) for perineal pain in the early postpartum period.

    PubMed

    Chou, Doris; Abalos, Edgardo; Gyte, Gillian M L; Gülmezoglu, A Metin

    2013-01-31

    Perineal pain is a common but poorly studied adverse outcome following childbirth. Pain may result from perineal trauma due to bruising, spontaneous tears, surgical incisions (episiotomies), or in association with operative births (ventouse or forceps assisted births). To determine the efficacy of a single administration of paracetamol (acetaminophen) systemic drugs used in the relief of acute postpartum perineal pain We updated the search of the Cochrane Pregnancy and Childbirth Group's Trials Register on 6 November 2012. Randomised controlled trials (RCTs) assessing paracetamol (acetaminophen) in a single dose compared with placebo for women with early postpartum perineal pain. We excluded quasi-RCTs and cross-over studies. Two review authors assessed each paper for inclusion and extracted data. One review author reviewed the decisions and confirmed calculations for pain relief scores. We did not identify any new trials from the updated search so the results remain unchanged as follows.We have included 10 studies describing two dosages of paracetamol. Of these, five studies (526 women) assessed 500 mg to 650 mg and six studies (841 women) assessed 1000 mg of paracetamol. We chose to use random-effects meta-analyses because of the heterogeneity in dosage used. Studies were from the 1970s to the early 1990s, and there was insufficient information to assess the risk of bias adequately, hence the findings need to be interpreted within this context.More women experienced pain relief with paracetamol compared with placebo (average risk ratio (RR) 2.14, 95% confidence interval (CI) 1.59 to 2.89, 10 studies, 1279 women). In addition, there were significantly fewer women having additional pain relief with paracetamol compared with placebo (RR 0.34, 95% CI 0.21 to 0.55, eight studies, 1132 women). Both the 500 mg to 650 mg and 1000 mg doses were effective in providing more pain relief than placebo.Maternal and neonatal potential adverse drug effects were not assessed in any of the included studies. Indeed few secondary outcomes were assessed. More women experienced pain relief, and fewer had additional pain relief, with paracetamol compared with placebo, although potential adverse effects were not assessed and generally the quality of studies was unclear.

  18. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    PubMed

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  19. Dual-energy computed tomography of the head: a phantom study assessing axial dose distribution, eye lens dose, and image noise level

    NASA Astrophysics Data System (ADS)

    Matsubara, Kosuke; Kawashima, Hiroki; Hamaguchi, Takashi; Takata, Tadanori; Kobayashi, Masanao; Ichikawa, Katsuhiro; Koshida, Kichiro

    2016-03-01

    The aim of this study was to propose a calibration method for small dosimeters to measure absorbed doses during dual- source dual-energy computed tomography (DECT) and to compare the axial dose distribution, eye lens dose, and image noise level between DE and standard, single-energy (SE) head CT angiography. Three DE (100/Sn140 kVp 80/Sn140 kVp, and 140/80 kVp) and one SE (120 kVp) acquisitions were performed using a second-generation dual-source CT device and a female head phantom, with an equivalent volumetric CT dose index. The axial absorbed dose distribution at the orbital level and the absorbed doses for the eye lens were measured using radiophotoluminescent glass dosimeters. CT attenuation numbers were obtained in the DE composite images and the SE images of the phantom at the orbital level. The doses absorbed at the orbital level and in the eye lens were lower and standard deviations for the CT attenuation numbers were slightly higher in the DE acquisitions than those in the SE acquisition. The anterior surface dose was especially higher in the SE acquisition than that in the DE acquisitions. Thus, DE head CT angiography can be performed with a radiation dose lower than that required for a standard SE head CT angiography, with a slight increase in the image noise level. The 100/Sn140 kVp acquisition revealed the most balanced axial dose distribution. In addition, our proposed method was effective for calibrating small dosimeters to measure absorbed doses in DECT.

  20. Assessment of Intrafraction Breathing Motion on Left Anterior Descending Artery Dose During Left-Sided Breast Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    El-Sherif, Omar, E-mail: Omar.ElSherif@lhsc.on.ca; Department of Physics, London Regional Cancer Program, London, Ontario; Yu, Edward

    Purpose: To use 4-dimensional computed tomography (4D-CT) imaging to predict the level of uncertainty in cardiac dose estimates of the left anterior descending artery that arises due to breathing motion during radiation therapy for left-sided breast cancer. Methods and Materials: The fast helical CT (FH-CT) and 4D-CT of 30 left-sided breast cancer patients were retrospectively analyzed. Treatment plans were created on the FH-CT. The original treatment plan was then superimposed onto all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion through 4D dose accumulation (4D-dose). Dose-volume histograms for the heart, left ventricle (LV), and left anteriormore » descending (LAD) artery obtained from the FH-CT were compared with those obtained from the 4D-dose. Results: The 95% confidence interval of 4D-dose and FH-CT differences in mean dose estimates for the heart, LV, and LAD were ±0.5 Gy, ±1.0 Gy, and ±8.7 Gy, respectively. Conclusion: Fast helical CT is a good approximation for doses to the heart and LV; however, dose estimates for the LAD are susceptible to uncertainties that arise due to intrafraction breathing motion that cannot be ascertained without the additional information obtained from 4D-CT and dose accumulation. For future clinical studies, we suggest the use of 4D-CT–derived dose-volume histograms for estimating the dose to the LAD.« less

  1. Is choline PET useful for identifying intraprostatic tumour lesions? A literature review.

    PubMed

    Chan, Joachim; Syndikus, Isabel; Mahmood, Shelan; Bell, Lynn; Vinjamuri, Sobhan

    2015-09-01

    More than 80% of patients with intermediate-risk or high-risk localized prostate cancer are cured with radiation doses of 74-78 Gy, but high doses increase the risk for late bowel and bladder toxicity among long-term survivors. Dose painting, defined as dose escalation to areas in the prostate containing the tumour, rather than to the whole gland, minimizes dose to normal tissues and hence toxicity. It requires accurate identification of the location and size of these lesions, for which functional MRI is the current gold standard. Many studies have assessed the use of choline PET in staging newly diagnosed patients. This review will discuss important imaging variables affecting the accuracy of choline PET scans, how choline PET contributes to tumour identification and is used in radiotherapy planning and how PET can improve the patient pathway involving prostate radiotherapy. In summary, the available literature shows that the accuracy of choline PET improves with higher tracer doses and delayed imaging (although the optimal uptake time is unclear), and tumour identification by MRI is improved by the addition of PET imaging. We propose future research with prolonged choline uptake time and multiphase imaging, which may further improve accuracy.

  2. The influence of dose, dose-rate and particle fragmentation on cataract induction by energetic iron ions

    NASA Technical Reports Server (NTRS)

    Medvedovsky, C.; Worgul, B. V.; Huang, Y.; Brenner, D. J.; Tao, F.; Miller, J.; Zeitlin, C.; Ainsworth, E. J.

    1994-01-01

    Because activities in space necessarily involve chronic exposure to a heterogeneous charged particle radiation field it is important to assess the influence of dose-rate and the possible modulating role of heavy particle fragmentation on biological systems. Using the well-studied cataract model, mice were exposed to plateau 600 MeV/amu Fe-56 ions either as acute or fractionated exposures at total doses of 5-504 cGy. Additional groups of mice received 20, 360 and 504 cGy behind 50 mm of polyethylene, which simulates body shielding. The reference radiation consisted of Co-60 gamma radiation. The animals were examined by slit lamp biomicroscopy over their three year life spans. In accordance with our previous observations with heavy particles, the cataractogenic potential of the 600 MeV/amu Fe-56 ions was greater than for low-Linear Energy Transfer (LET) radiation and increased with decreasing dose relative to gamma rays. Fractionation of a given dose of Fe-56 ions did not reduce the cataractogenicity of the radiation compared to the acute regimen. Fragmentation of the beam in the polyethylene did not alter the cataractotoxicity of the ions, either when administered singly or in fractions.

  3. The influence of dose, dose-rate and particle fragmentation on cataract induction by energetic iron ions

    NASA Astrophysics Data System (ADS)

    Medvedovsky, C.; Worgul, B. V.; Huang, Y.; Brenner, D. J.; Tao, F.; Miller, J.; Zeitlin, C.; Ainsworth, E. J.

    1994-10-01

    Because activities in space necessarily involve chronic exposure to a heterogeneous charged particle radiation field it is important to assess the influence of dose-rate and the possible modulating role of heavy particle fragmentation on biological systems. Using the well-studied cataract model, mice were exposed to plateau 600 MeV/amu 56Fe ions either as acute or fractionated exposures at total doses of 5 - 504 cGy. Additional groups of mice received 20, 360 and 504 cGy behind 50 mm of polyethylene, which simulates body shielding. The reference radiation consisted of 60Co γ radiation. The animals were examined by slit lamp biomicroscopy over their three year life spans. In accordance with our previous observations with heavy particles, the cataractogenic potential of the 600 MeV/amu 56Fe ions was greater than for low-LET radiation and increased with decreasing dose relative to γ-rays. Fractionation of a given dose of 56Fe ions did not reduce the cataractogenicity of the radiation compared to the acute regimen. Fragmentation of the beam in the polyethylene did not alter the cataractotoxicity of the ions, either when administered singly or in fractions.

  4. Assessment of physician and patient (child and adult) equivalent doses during renal angiography by Monte Carlo method.

    PubMed

    Karimian, A; Nikparvar, B; Jabbari, I

    2014-11-01

    Renal angiography is one of the medical imaging methods in which patient and physician receive high equivalent doses due to long duration of fluoroscopy. In this research, equivalent doses of some radiosensitive tissues of patient (adult and child) and physician during renal angiography have been calculated by using adult and child Oak Ridge National Laboratory phantoms and Monte Carlo method (MCNPX). The results showed, in angiography of right kidney in a child and adult patient, that gall bladder with the amounts of 2.32 and 0.35 mSv, respectively, has received the most equivalent dose. About the physician, left hand, left eye and thymus absorbed the most amounts of doses, means 0.020 mSv. In addition, equivalent doses of the physician's lens eye, thyroid and knees were 0.023, 0.007 and 7.9E-4 mSv, respectively. Although these values are less than the reported thresholds by ICRP 103, it should be noted that these amounts are related to one examination. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Dose constraints in the rectum and bladder following carbon-ion radiotherapy for uterus carcinoma: a retrospective pooled analysis.

    PubMed

    Okonogi, Noriyuki; Fukahori, Mai; Wakatsuki, Masaru; Ohkubo, Yu; Kato, Shingo; Miyasaka, Yuhei; Tsuji, Hiroshi; Nakano, Takashi; Kamada, Tadashi

    2018-06-25

    Carbon-ion radiotherapy (C-ion RT) provides better dose distribution in cancer treatment compared to photons. Additionally, carbon-ion beams provide a higher biological effectiveness, and thus a higher tumor control probability. However, information regarding the dose constraints for organs at risk in C-ion RT is limited. This study aimed to determine the predictive factors for late morbidities in the rectum and bladder after carbon-ion C-ion RT for uterus carcinomas. Between June 1995 and January 2010, 134 patients with uterus carcinomas were treated with C-ion RT with curative intent; prescription doses of 52.8-74.4 Gy (relative biological effectiveness) were delivered in 20-24 fractions. Of these patients, 132 who were followed up for > 6 months were analyzed. We separated the data in two subgroups, a 24 fractions group and a 20 fractions group. Late morbidities, proctitis, and cystitis were assessed according to the Radiation Therapy Oncology Group/European Organisation for Research and Treatment of Cancer criteria. The correlations of clinical and dosimetric parameters, V10-V60, D 5cc , D 2cc , and Dmax, with the incidence of ≥grade 1 morbidities were retrospectively analyzed. In the 24 fractions group, the 3-year actuarial occurrence rates of ≥grade 1 rectal and bladder morbidities were 64 and 9%, respectively. In addition, in the 20 fractions group, the 3-year actuarial occurrence rates of ≥grade 1 rectal and bladder morbidities were 32 and 19%, respectively. Regarding the dose-volume histogram data on the rectum, the D 5cc and D 2cc were significantly higher in patients with ≥grade 1 proctitis than in those without morbidity. In addition, the D 5cc for the bladder was significantly higher in patients with ≥grade 1 cystitis than in those without morbidity. Results of univariate analyses showed that D 2cc of the rectum was correlated with the development of ≥grade 1 late proctitis. Moreover, D 5cc of the bladder was correlated with the development of ≥grade 1 late cystitis. The present study identified the dose-volume relationships in C-ion RT regarding the occurrence of late morbidities in the rectum and bladder. Assessment of the factors discussed herein would be beneficial in preventing late morbidities after C-ion RT for pelvic malignancies. Retrospectively registered ( NIRS: 16-040 ).

  6. A Signal-to-Noise Crossover Dose as the Point of Departure for Health Risk Assessment

    PubMed Central

    Portier, Christopher J.; Krewski, Daniel

    2011-01-01

    Background: The U.S. National Toxicology Program (NTP) cancer bioassay database provides an opportunity to compare both existing and new approaches to determining points of departure (PoDs) for establishing reference doses (RfDs). Objectives: The aims of this study were a) to investigate the risk associated with the traditional PoD used in human health risk assessment [the no observed adverse effect level (NOAEL)]; b) to present a new approach based on the signal-to-noise crossover dose (SNCD); and c) to compare the SNCD and SNCD-based RfD with PoDs and RfDs based on the NOAEL and benchmark dose (BMD) approaches. Methods: The complete NTP database was used as the basis for these analyses, which were performed using the Hill model. We determined NOAELs and estimated corresponding extra risks. Lower 95% confidence bounds on the BMD (BMDLs) corresponding to extra risks of 1%, 5%, and 10% (BMDL01, BMDL05, and BMDL10, respectively) were also estimated. We introduce the SNCD as a new PoD, defined as the dose where the additional risk is equal to the “background noise” (the difference between the upper and lower bounds of the two-sided 90% confidence interval on absolute risk) or a specified fraction thereof. Results: The median risk at the NOAEL was approximately 10%, and the default uncertainty factor (UF = 100) was considered most applicable to the BMDL10. Therefore, we chose a target risk of 1/1,000 (0.1/100) to derive an SNCD-based RfD by linear extrapolation. At the median, this approach provided the same RfD as the BMDL10 divided by the default UF. Conclusions: Under a standard BMD approach, the BMDL10 is considered to be the most appropriate PoD. The SNCD approach, which is based on the lowest dose at which the signal can be reliably detected, warrants further development as a PoD for human health risk assessment. PMID:21813365

  7. Validation of self-reported cannabis dose and potency: an ecological study.

    PubMed

    van der Pol, Peggy; Liebregts, Nienke; de Graaf, Ron; Korf, Dirk J; van den Brink, Wim; van Laar, Margriet

    2013-10-01

    To assess the reliability and validity of self-reported cannabis dose and potency measures. Cross-sectional study comparing self-reports with objective measures of amount of cannabis and delta-9-tetrahydrocannabinol (THC) concentration. Ecological study with assessments at participants' homes or in a coffee shop. Young adult frequent cannabis users (n = 106) from the Dutch Cannabis Dependence (CanDep) study. The objectively measured amount of cannabis per joint (dose in grams) was compared with self-reported estimates using a prompt card and average number of joints made from 1 g of cannabis. In addition, objectively assessed THC concentration in the participant's cannabis was compared with self-reported level of intoxication, subjective estimate of cannabis potency and price per gram of cannabis. Objective estimates of doses per joint (0.07-0.88 g/joint) and cannabis potency (1.1-24.7%) varied widely. Self-reported measures of dose were imprecise, but at group level, average dose per joint was estimated accurately with the number of joints made from 1 g [limit of agreement (LOA) = -0.02 g, 95% confidence interval (CI) = -0.29; 0.26], whereas the prompt card resulted in serious underestimation (LOA = 0.14 g, 95% CI = -0.10; 0.37). THC concentration in cannabis was associated with subjective potency ['average' 3.77% (P = 0.002) and '(very) strong' 5.13% more THC (P < 0.001) than '(very) mild' cannabis] and with cannabis price (about 1% increase in THC concentration per euro spent on 1 g of cannabis, P < 0.001), but not with level of intoxication. Self-report measures relating to cannabis use appear at best to be associated weakly with objective measures. Of the self-report measures, number of joints per gram, cannabis price and subjective potency have at least some validity. © 2013 Society for the Study of Addiction.

  8. Low-Dose Carcinogenicity Studies

    EPA Science Inventory

    One of the major deficiencies of cancer risk assessments is the lack of low-dose carcinogenicity data. Most assessments require extrapolation from high to low doses, which is subject to various uncertainties. Only 4 low-dose carcinogenicity studies and 5 low-dose biomarker/pre-n...

  9. 75 FR 5526 - Chlorantraniliprole; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-03

    ... April 5, 2010. In addition to filing an objection or hearing request with the Hearing Clerk as described... ppm; atemoya at 4.0 ppm; avocado at 4.0 ppm; banana at 4.0 ppm; biriba at 4.0 ppm; black sapote at 4.0... reference values for risk assessment. The POD may be defined as the highest dose at which no adverse effects...

  10. Effects of feeding lauric acid on ruminal protozoa numbers, fermentation, and digestion and on milk production in dairy cows

    USDA-ARS?s Scientific Manuscript database

    The objectives of this study were: (1) to determine the level of lauric acid (LA) addition to the diet necessary to effectively suppress ruminal protozoa (RP) to the extent observed when a single dose was given directly into the rumen; (2) to assess its effects on production and ruminal metabolism; ...

  11. Adverse effects of levamisole in cocaine users: a review and risk assessment.

    PubMed

    Brunt, Tibor Markus; van den Berg, Jorrit; Pennings, Ed; Venhuis, Bastiaan

    2017-06-01

    The immunomodulatory adjuvant and antihelminth levamisole is increasingly used as an adulterant in cocaine worldwide. An accumulating body of clinical and toxicological literature has appeared since 2010 describing neutropenia, agranulocytosis, leukoencephalopathy and vasculitis in cases associated with levamisole-adulterated cocaine. Mostly, neutropenia and agranulocytosis were reported, characterized by a decimation of neutrophils. A large proportion of cases also involved vasculopathy, characterized by pronounced black and purple skin purpura with cutaneous necrosis. Females are more susceptible for both agranulocytosis and vasculitis. Another complication reported with levamisole-adulterated cocaine is leukoencephalopathy, a disabling and potentially fatal neurological disorder caused by cerebral demyelination. In this review, all adverse effects associated with therapeutic levamisole and levamisole-adulterated cocaine are described. In addition, this review provides an update of the pharmacology of levamisole, its metabolism, including toxic metabolites and metabolites that are relevant for levamisole's addition to cocaine. Special emphasis is put on the immunopathology and the dose-effect relationship of chronic levamisole exposure. Finally, a risk assessment is provided based on the current level of levamisole adulteration in street cocaine, the dose range calculated per gram and the pattern of chronic exposure in heavy or dependent users.

  12. New challenges in risk assessment of chemicals when simulating real exposure scenarios; simultaneous multi-chemicals' low dose exposure.

    PubMed

    Tsatsakis, Aristidis M; Docea, Anca Oana; Tsitsimpikou, Christina

    2016-10-01

    The general population experiences uncontrolled multi-chemicals exposure from many different sources at doses around or well below regulatory limits. Therefore, traditional chronic toxicity evaluations for a single chemical could possibly miss to identify adequately all the risks. For this an experimental methodology that has the ambition to provide at one strike multi-answers to multi-questions is hereby proposed: a long-term toxicity study of non-commercial chemical mixtures, consisting of common everyday life chemicals (pesticides, food additives, life-style products components) at low and realistic dose levels around the regulatory limits and with the simultaneous investigation of several key endpoints, like genotoxicity, endocrine disruption, target organ toxicity including the heart and systemic mechanistic pathways, like oxidative stress. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Rational design of gold nanoparticle toxicology assays: a question of exposure scenario, dose and experimental setup.

    PubMed

    Taylor, Ulrike; Rehbock, Christoph; Streich, Carmen; Rath, Detlef; Barcikowski, Stephan

    2014-09-01

    Many studies have evaluated the toxicity of gold nanoparticles, although reliable predictions based on these results are rare. In order to overcome this problem, this article highlights strategies to improve comparability and standardization of nanotoxicological studies. To this end, it is proposed that we should adapt the nanomaterial to the addressed exposure scenario, using ligand-free nanoparticle references in order to differentiate ligand effects from size effects. Furthermore, surface-weighted particle dosing referenced to the biologically relevant parameter (e.g., cell number or organ mass) is proposed as the gold standard. In addition, it is recommended that we should shift the focus of toxicological experiments from 'live-dead' assays to the assessment of cell function, as this strategy allows observation of bioresponses at lower doses that are more relevant for in vivo scenarios.

  14. Tranexamic Acid: From Trauma to Routine Perioperative Use

    PubMed Central

    Simmons, Jeff; Sikorski, Robert A.; Pittet, Jean-Francois

    2015-01-01

    Purpose Of Review Optimizing hemostasis with antifibrinolytics is becoming a common surgical practice. Large clinical studies have demonstrated efficacy and safety of tranexamic acid (TXA) in the trauma population to reduce blood loss and transfusions. Its use in patients without preexisting coagulopathies is debated, as thromboembolic events are a concern. In this review, perioperative administration of TXA is examined in non-trauma surgical populations. Additionally, risk of thromboembolism, dosing regimens, and timing of dosing are assessed. Recent Findings Perioperative use of tranexamic acid is associated with reduced blood loss and transfusions. Thromboembolic effects do not appear to be increased. However, optimal dosing and timing of TXA administration is still under investigation for non-trauma surgical populations. Summary As part of a perioperative blood management program, tranexamic acid can be used to help reduce blood loss and mitigate exposure to blood transfusion. PMID:25635366

  15. Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy?

    PubMed

    Keall, Paul J; Nguyen, Doan Trang; O'Brien, Ricky; Zhang, Pengpeng; Happersett, Laura; Bertholet, Jenny; Poulsen, Per R

    2018-04-14

    To review real-time 3-dimensional (3D) image guided radiation therapy (IGRT) on standard-equipped cancer radiation therapy systems, focusing on clinically implemented solutions. Three groups in 3 continents have clinically implemented novel real-time 3D IGRT solutions on standard-equipped linear accelerators. These technologies encompass kilovoltage, combined megavoltage-kilovoltage, and combined kilovoltage-optical imaging. The cancer sites treated span pelvic and abdominal tumors for which respiratory motion is present. For each method the 3D-measured motion during treatment is reported. After treatment, dose reconstruction was used to assess the treatment quality in the presence of motion with and without real-time 3D IGRT. The geometric accuracy was quantified through phantom experiments. A literature search was conducted to identify additional real-time 3D IGRT methods that could be clinically implemented in the near future. The real-time 3D IGRT methods were successfully clinically implemented and have been used to treat more than 200 patients. Systematic target position shifts were observed using all 3 methods. Dose reconstruction demonstrated that the delivered dose is closer to the planned dose with real-time 3D IGRT than without real-time 3D IGRT. In addition, compromised target dose coverage and variable normal tissue doses were found without real-time 3D IGRT. The geometric accuracy results with real-time 3D IGRT had a mean error of <0.5 mm and a standard deviation of <1.1 mm. Numerous additional articles exist that describe real-time 3D IGRT methods using standard-equipped radiation therapy systems that could also be clinically implemented. Multiple clinical implementations of real-time 3D IGRT on standard-equipped cancer radiation therapy systems have been demonstrated. Many more approaches that could be implemented were identified. These solutions provide a pathway for the broader adoption of methods to make radiation therapy more accurate, impacting tumor and normal tissue dose, margins, and ultimately patient outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Addition of Lubiprostone to polyethylene glycol(PEG) enhances the quality & efficacy of colonoscopy preparation: a randomized, double-blind, placebo controlled trial.

    PubMed

    Banerjee, Rupa; Chaudhari, Hrushikesh; Shah, Nirish; Saravanan, Arjunan; Tandan, Manu; Reddy, D Nageshwar

    2016-10-13

    Adequate bowel preparation is an essential prerequisite for complete mucosal visualization during colonoscopy. Polyethylene glycol (PEG) solutions are commonly used. However the large volume of the solution is often poorly tolerated. Addition of Lubiprostone (LB) could improve the adequacy of standard PEG preparation & reduce requirement. The aims to assess adequacy of PEG preparation with addition of single dose LB (24mcg) vs placebo and efficacy of reduced dose PEG + LB compared with full dose PEG + LB. Single center prospective double blind randomized controlled trial. Part I: 442 patients for colonoscopy randomized to receive placebo (GrA) or single dose of LB (GrB) prior to PEG preparation. Quality of bowel preparation graded 0-9 according to Boston Bowel Preparation Scale (BBPS). BBPS-9: excellent and BBPS 0-4: repeat procedure. Part II: 146 patients randomized to receive LB + 1.5 L PEG (GrC; 75) or LB + 1 L PEG (GrD; 71). BBPS score compared with GrB (2 L PEG). Part I: 442 patients (221 GrA & 221 Gr B). LB resulted in significant improvement in total BBPS (7.44 + 0.14 vs. 6.36 + 0.16, p < 0.0001). 66.5 % Gr B vs 38 % Gr A had excellent prep; 42.5 % GrB vs 24 % GrA had adequate prep. Repeat procedure needed 9.5 % Gr B vs 16.7 % Gr A (P < 0.01). Part II: No difference in BBPS scores with lower doses (Gr C&D) compared to standard (GrB) (Mean BBPS 7.44 + 0.14 GrA,7.30 + 0.25 GrC;7.25 + 0.26 GrD;p >0.05). Single dose LB prior to PEG significantly enhanced bowel preparation compared to PEG alone. There was no significant difference in quality of preparation with lower doses of PEG when combined with LB. The study protocol was approved by institutional review board and the trial was registered on March 22, 2011 with clinicaltrials.gov ( NCT01324284 ).

  17. Acute and developmental toxicity assessment of erincine A-enriched Hericium erinaceus mycelia in Sprague-Dawley rats.

    PubMed

    Li, I-Chen; Chen, Wan-Ping; Chen, Yen-Po; Lee, Li-Ya; Tsai, Yueh-Ting; Chen, Chin-Chu

    2018-01-23

    This study aimed to establish an in vitro model to confirm the efficacy of erinacine A-enriched Hericium erinaceus (EAHE) mycelia and investigate its potential adverse effects in a preclinical experimental setting, including an assessment on the oral administration of EAHE mycelia in acute and prenatal developmental toxicity tests. At a single dose of 5000 mg/kg body weight, EAHE mycelia elicited no death or treatment-related signs of toxicity in ten Sprague-Dawley rats of both sexes during the 14 days of the experimental period. After considering the recommended dose range of EAHE mycelia from the acute toxicity test as well as the therapeutic doses, EAHE mycelia was administered to 66 pregnant rats in the low, medium, and high-dose groups by gavage at 875, 1750, and 2625 mg/kg body weight, respectively. All dams were subjected to a Caesarean section on the 20th day of pregnancy, and the fetuses were examined for any morphological abnormalities. Results indicated that weight of uterus, fetal body weight, number of corpora lutea, implantation sites, pre-implantation loss, and post-implantation loss of the treatment groups and the control group exhibited no statistical difference. In addition, no significant differences were observed in the fetal external, organ, and skeletal examinations. Taken together, it can be concluded that EAHE mycelia is considered safe and practically nontoxic for consumption within the appropriate doses and investigation period in this study.

  18. The application of drug dose equivalence in the quantitative analysis of receptor occupation and drug combinations

    PubMed Central

    Tallarida, Ronald J.; Raffa, Robert B.

    2014-01-01

    In this review we show that the concept of dose equivalence for two drugs, the theoretical basis of the isobologram, has a wider use in the analysis of pharmacological data derived from single and combination drug use. In both its application to drug combination analysis with isoboles and certain other actions, listed below, the determination of doses, or receptor occupancies, that yield equal effects provide useful metrics that can be used to obtain quantitative information on drug actions without postulating any intimate mechanism of action. These other drug actions discussed here include (1) combinations of agonists that produce opposite effects, (2) analysis of inverted U-shaped dose effect curves of single agents, (3) analysis on the effect scale as an alternative to isoboles and (4) the use of occupation isoboles to examine competitive antagonism in the dual receptor case. New formulas derived to assess the statistical variance for additive combinations are included, and the more detailed mathematical topics are included in the appendix. PMID:20546783

  19. Radioactive Waste Management Complex low-level waste radiological performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maheras, S.J.; Rood, A.S.; Magnuson, S.O.

    This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsitemore » receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.« less

  20. Human health risk assessment of the mixture of pharmaceuticals in Dutch drinking water and its sources based on frequent monitoring data.

    PubMed

    Houtman, Corine J; Kroesbergen, Jan; Lekkerkerker-Teunissen, Karin; van der Hoek, Jan Peter

    2014-10-15

    The presence of pharmaceuticals in drinking water is a topic of concern. Previous risk assessments indicate that their low concentrations are very unlikely to pose risks to human health, however often conclusions had to be based on small datasets and mixture effects were not included. The objectives of this study were to a) investigate if pharmaceuticals in surface and polder water penetrate in drinking water, b) assess the lifelong exposure of consumers to pharmaceuticals via drinking water and c) assess the possible individual and mixture health risks associated with this exposure. To fulfill these aims, a 2-year set of 4-weekly monitoring data of pharmaceuticals was used from three drinking water production plants. The 42 pharmaceuticals that were monitored were selected according to their consumption volume, earlier detection, toxicity and representation of the most relevant therapeutic classes. Lifelong exposures were calculated from concentrations and compared with therapeutic doses. Health risks were assessed by benchmarking concentrations with provisional guideline values. Combined risks of mixtures of pharmaceuticals were estimated using the concept of Concentration Addition. The lifelong exposure to pharmaceuticals via drinking water was calculated to be extremely low, i.e. a few mg, in total corresponding to <10% of the dose a patient is administered on one day. The risk of adverse health effects appeared to be negligibly low. Application of Concentration Addition confirmed this for the mixture of pharmaceuticals simultaneously present. The investigated treatment plants appeared to reduce the (already negligible) risk up to 80%. The large available monitoring dataset enabled the performance of a realistic risk assessment. It showed that working with maximum instead of average concentrations may overestimate the risk considerably. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Application of the DG-1199 methodology to the ESBWR and ABWR.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalinich, Donald A.; Gauntt, Randall O.; Walton, Fotini

    2010-09-01

    Appendix A-5 of Draft Regulatory Guide DG-1199 'Alternative Radiological Source Term for Evaluating Design Basis Accidents at Nuclear Power Reactors' provides guidance - applicable to RADTRAD MSIV leakage models - for scaling containment aerosol concentration to the expected steam dome concentration in order to preserve the simplified use of the Accident Source Term (AST) in assessing containment performance under assumed design basis accident (DBA) conditions. In this study Economic and Safe Boiling Water Reactor (ESBWR) and Advanced Boiling Water Reactor (ABWR) RADTRAD models are developed using the DG-1199, Appendix A-5 guidance. The models were run using RADTRAD v3.03. Low Populationmore » Zone (LPZ), control room (CR), and worst-case 2-hr Exclusion Area Boundary (EAB) doses were calculated and compared to the relevant accident dose criteria in 10 CFR 50.67. For the ESBWR, the dose results were all lower than the MSIV leakage doses calculated by General Electric/Hitachi (GEH) in their licensing technical report. There are no comparable ABWR MSIV leakage doses, however, it should be noted that the ABWR doses are lower than the ESBWR doses. In addition, sensitivity cases were evaluated to ascertain the influence/importance of key input parameters/features of the models.« less

  2. Sterile Basics of Compounding: Relationship Between Syringe Size and Dosing Accuracy.

    PubMed

    Kosinski, Tracy M; Brown, Michael C; Zavala, Pedro J

    2018-01-01

    The purpose of this study was to investigate the accuracy and reproducibility of a 2-mL volume injection using a 3-mL and 10-mL syringe with pharmacy student compounders. An exercise was designed to assess each student's accuracy in compounding a sterile preparation with the correct 4-mg strength using a 3-mL and 10-mL syringe. The average ondansetron dose when compounded with the 3-mL syringe was 4.03 mg (standard deviation ± 0.45 mg), which was not statistically significantly different than the intended 4-mg desired dose (P=0.497). The average ondansetron dose when compounded with the 10-mL syringe was 4.18 mg (standard deviation + 0.68 mg), which was statistically significantly different than the intended 4-mg desired dose (P=0.002). Additionally, there also was a statistically significant difference in the average ondansetron dose compounded using a 3-mL syringe (4.03 mg) and a 10-mL syringe (4.18 mg) (P=0.027). The accuracy and reproducibility of the 2-mL desired dose volume decreased as the compounding syringe size increased from 3 mL to 10 mL. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  3. Bath and Shower Effects in the Rat Parotid Gland Explain Increased Relative Risk of Parotid Gland Dysfunction After Intensity-Modulated Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luijk, Peter van; Faber, Hette; Schippers, Jacobus M.

    2009-07-15

    Purpose: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect). Methods and Materials: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.e., subtolerance) dose levels for a bath-dose, both whole parotid glands were irradiated with 5 to 25 Gy. Subsequently groups of Wistar rats received 30 Gy to the caudal 50% (shower) and 0 to 10 Gy to the cranial 50% (bath) ofmore » both parotid glands. Stimulated saliva flow rate (function) was measured before and up to 240 days after irradiation. Results: Irradiation of both glands up to a dose of 10 Gy did not result in late loss of function and is thus regarded subtolerance. Addition of a dose bath of 1 to 10 Gy to a high-dose in the caudal 50% of the glands resulted in enhanced function loss. Conclusion: Similar to the spinal cord, the parotid gland demonstrates a bath and shower effect, which may explain the less-than-expected sparing of function after IMRT.« less

  4. RADTRAD: A simplified model for RADionuclide Transport and Removal And Dose estimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humphreys, S.L.; Miller, L.A.; Monroe, D.K.

    1998-04-01

    This report documents the RADTRAD computer code developed for the U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Reactor Regulation (NRR) to estimate transport and removal of radionuclides and dose at selected receptors. The document includes a users` guide to the code, a description of the technical basis for the code, the quality assurance and code acceptance testing documentation, and a programmers` guide. The RADTRAD code can be used to estimate the containment release using either the NRC TID-14844 or NUREG-1465 source terms and assumptions, or a user-specified table. In addition, the code can account for a reduction in themore » quantity of radioactive material due to containment sprays, natural deposition, filters, and other natural and engineered safety features. The RADTRAD code uses a combination of tables and/or numerical models of source term reduction phenomena to determine the time-dependent dose at user-specified locations for a given accident scenario. The code system also provides the inventory, decay chain, and dose conversion factor tables needed for the dose calculation. The RADTRAD code can be used to assess occupational radiation exposures, typically in the control room; to estimate site boundary doses; and to estimate dose attenuation due to modification of a facility or accident sequence.« less

  5. Internal versus External Dose for Describing Ternary Metal Mixture (Ni, Cu, Cd) Chronic Toxicity to Lemna minor.

    PubMed

    Gopalapillai, Yamini; Hale, Beverley A

    2017-05-02

    Simultaneous determinations of internal dose ([M] tiss ) and external doses ([M] tot , {M 2+ } in solution) were conducted to study ternary mixture (Ni, Cu, Cd) chronic toxicity to Lemna minor in alkaline solution (pH 8.3). Also, concentration addition (CA) based on internal dose was evaluated as a tool for risk assessment of metal mixture. Multiple regression analysis of dose versus root growth inhibition, as well as saturation binding kinetics, provided insight into interactions. Multiple regressions were simpler for [M] tiss than [M] tot and {M 2+ }, and along with saturation kinetics to the internal biotic ligand(s) in the cytoplasm, they indicated that Ni-Cu-Cd competed for uptake into plant, but once inside, only Cu-Cd shared a binding site. Copper inorganic complexes (hydroxides, carbonates) played a role in metal bioavailability in single metal exposure but not in mixtures. Regardless of interactions, the current regulatory approach of using CA based on [M] tot can sufficiently predict mixture toxicity (∑TU close to 1), but CA based on [M] tiss was closest to unity across a range of doses. Internal dose integrates all metal-metal interactions in solution and during uptake into the organism, thereby providing a more direct metric describing toxicity.

  6. Assessing doses to interventional radiologists using a personal dosimeter worn over a protective apron.

    PubMed

    Stranden, E; Widmark, A; Sekse, T

    2008-05-01

    Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron.

  7. Potential Offsite Radiological Doses Estimated for the Proposed Divine Strake Experiment, Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ron Warren

    2006-12-01

    An assessment of the potential radiation dose that residents offsite of the Nevada Test Site (NTS) might receive from the proposed Divine Strake experiment was made to determine compliance with Subpart H of Part 61 of Title 40 of the Code of Federal Regulations, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. The Divine Strake experiment, proposed by the Defense Threat Reduction Agency, consists of a detonation of 700 tons of heavy ammonium nitrate fuel oil-emulsion above the U16b Tunnel complex in Area 16 of the NTS. Both natural radionuclides suspended, and historicmore » fallout radionuclides resuspended from the detonation, have potential to be transported outside the NTS boundary by wind. They may, therefore, contribute radiological dose to the public. Subpart H states ''Emissions of radionuclides to the ambient air from Department of Energy facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent of 10 mrem/yr'' (Title 40 of the Code of Federal Regulations [CFR] 61.92) where mrem/yr is millirem per year. Furthermore, application for U.S. Environmental Protection Agency (EPA) approval of construction of a new source or modification of an existing source is required if the effective dose equivalent, caused by all emissions from the new construction or modification, is greater than or equal to 0.1 mrem/yr (40 CFR 61.96). In accordance with Section 61.93, a dose assessment was conducted with the computer model CAP88-PC, Version 3.0. In addition to this model, a dose assessment was also conducted by the National Atmospheric Release Advisory Center (NARAC) at the Lawrence Livermore National Laboratory. This modeling was conducted to obtain dose estimates from a model designed for acute releases and which addresses terrain effects and uses meteorology from multiple locations. Potential radiation dose to a hypothetical maximally exposed individual at the closest NTS boundary to the proposed Divine Strake experiment, as estimated by the CAP88-PC model, was 0.005 mrem with wind blowing directly towards that location. Boundary dose, as modeled by NARAC, ranged from about 0.006 to 0.007 mrem. Potential doses to actual offsite populated locations were generally two to five times lower still, or about 40 to 100 times lower then the 0.1 mrem level at which EPA approval is required pursuant to Section 61.96.« less

  8. EVALUATING QUANTITATIVE FORMULAS FOR DOSE-RESPONSE ASSESSMENT OF CHEMICAL MIXTURES

    EPA Science Inventory

    Risk assessment formulas are often distinguished from dose-response models by being rough but necessary. The evaluation of these rough formulas is described here, using the example of mixture risk assessment. Two conditions make the dose-response part of mixture risk assessment d...

  9. Comparison of Etomidate, Benzocaine, and MS222 Anesthesia with and without Subsequent Flunixin Meglumine Analgesia in African Clawed Frogs (Xenopus laevis).

    PubMed

    Smith, Briony D; Vail, Krystal J; Carroll, Gwendolyn L; Taylor, Maggie C; Jeffery, Nicholas D; Vemulapalli, Tracy H; Elliott, James J

    2018-03-01

    Often few alternative anesthetics for exotic species are available, due to the small numbers of these animals used in research. In this study, we evaluated the depth and duration of anesthesia in Xenopus laevis after their immersion in 3 doses of etomidate (15, 22.5, and 30 mg/L) and in 3 doses of benzocaine (0.1%, 0.5%, and 1%) compared with the 'gold standard,' tricaine methanesulfonate (MS222; 2 g/L). We then chose an optimal dose for each alternative anesthetic according to induction time, duration of surgical plane, and time to complete recovery. The optimal etomidate and benzocaine doses (22.5 mg/L and 0.1%, respectively) as well as the MS222 dose were then used to achieve a surgical plane of anesthesia, with the addition of flunixin meglumine (25 or 50 mg/kg) administered in the dorsal lymph sac at the completion of mock oocyte harvest. Efficacy of the analgesic was assessed at 1, 3, 6, and 24 h postoperatively by using acetic acid testing (AAT). Histology of the liver, kidney, and tissues surrounding the dorsal lymph sac was performed at day 3, 14, and 28 in each group of animals. Mild to moderate myocyte degeneration and necrosis were present in tissues surrounding the dorsal lymph sac at both flunixin meglumine doses after etomidate and benzocaine anesthesia. In addition, the 50-mg/kg dose of flunixin meglumine resulted in the death of 5 of the 12 frogs within 24 h, despite an otherwise uneventful anesthetic recovery. In conclusion, benzocaine and etomidate offer alternative anesthetic regimens, according to typical requirements for an anesthetic event. Flunixin meglumine at the 25-mg/kg dose provided analgesic relief at the latest time point during etomidate dosage and at all time points during benzocaine dosage, but further characterization is warranted regarding long-term or repeated analgesic administration.

  10. p-Nitrophenol removal by combination of powdered activated carbon adsorption and ultrafiltration - comparison of different operational modes.

    PubMed

    Ivancev-Tumbas, Ivana; Hobby, Ralph; Küchle, Benjamin; Panglisch, Stefan; Gimbel, Rolf

    2008-09-01

    Ultrafiltration is classified as a low-pressure membrane technology which effectively removes particulate matter and microorganisms and to a certain extent dissolved organic matter (15-25%) and colour. The technology has been optimized and is becoming competitive compared to conventional processes for larger scale plant capacities. In combination with activated carbon it is an effective barrier regarding the removal of synthetic organic chemicals. Growing interest in ultrafiltration raises the question of better usage of the adsorption capacity of powdered activated carbon (PAC) used in combination with this low-pressure membrane technique. This paper presents a pilot plant study of different PAC dosing procedures within a combined hybrid membrane IN/OUT process for removal of p-nitrophenol (PNP) from water (c(0)=1mg/L) under real case conditions (e.g. usage of the same module for the whole duration of the experiment, backwashing with permeate water, no separate saturation of the membrane with substance without presence of carbon). p-Nitrophenol was chosen as an appropriate test substance to assess the efficiency of different operation modes. Dead-end and cross-flow filtration were compared with respect to different PAC dosing procedures: continuous dosing into a continuously stirred tank reactor (CSTR) in front of the module and direct dosing into the pipe in front of the module (continuous, single-pulse and multi-pulse dosing). There was no advantage in cross-flow mode over dead-end referring to PNP concentration in the permeate. Relating to the carbon dosing procedure, the best results were obtained for continuous PAC addition. The option of dosing directly into the pipe has the advantage of no additional tank being necessary. In the case of single-pulse dosing, the formation of a carbon layer on the membrane surface was assumed and an LDF model applied for a simplified estimation of the "breakthrough behaviour" in the thus formed "PAC filter layer".

  11. Do adjuvants add to the efficacy and tolerance of bowel preparations? A meta-analysis of randomized trials.

    PubMed

    Restellini, Sophie; Kherad, Omar; Menard, Charles; Martel, Myriam; Barkun, Alan N

    2018-02-01

    BACKGROUND AND STUDY AIMS : Recommendations on adjuvant use with bowel preparations remain disparate. We performed a meta-analysis determining the clinical impact of adding an adjuvant to polyethylene glycol (PEG), sodium phosphate, picosulfate (PICO), or oral sulfate solutions (OSS)-based regimens.  Systematic searches were made of MEDLINE, EMBASE, Scopus, CENTRAL and ISI Web of knowledge for randomized trials from January 1980 to April 2016 that assessed preparations with or without adjuvants, given in split and non-split dosing, and PEG high- (> 3 L) or low-dose (≤ 2 L) regimens. Bowel cleansing efficacy was the primary outcome. Secondary outcomes included patient willingness to repeat the procedure, and polyp and adenoma detection rates.  Of 3093 citations, 77 trials fulfilled the inclusion criteria. Overall, addition of an adjuvant compared with no adjuvant, irrespective of the type of preparation and mode of administration, yielded improvements in bowel cleanliness (odds ratio [OR] 1.23 [1.01 - 1.51]) without greater willingness to repeat (OR 1.40 [0.91 - 2.15]). Adjuvants combined with high-dose PEG significantly improved colon cleansing (OR 1.96 [1.32 - 2.94]). The odds for achieving adequate preparation with low-dose PEG with an adjuvant were not different to high-dose PEG alone (OR 0.95 [0.73 - 1.22]), but yielded improved tolerance (OR 3.22 [1.85 - 5.55]). However, split high-dose PEG yielded superior cleanliness to low-dose PEG with adjuvants (OR 2.53 [1.25 - 5.13]). No differences were noted for OSS and PICO comparisons, or for any products regarding polyp or adenoma detection rates.  Critical heterogeneity precludes firm conclusion on the impact of adjuvants with existing bowel preparations. Additional research is required to better characterize the methods of administration and resulting roles of adjuvants in an era of split-dosing. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Methods for Probabilistic Radiological Dose Assessment at a High-Level Radioactive Waste Repository.

    NASA Astrophysics Data System (ADS)

    Maheras, Steven James

    Methods were developed to assess and evaluate the uncertainty in offsite and onsite radiological dose at a high-level radioactive waste repository to show reasonable assurance that compliance with applicable regulatory requirements will be achieved. Uncertainty in offsite dose was assessed by employing a stochastic precode in conjunction with Monte Carlo simulation using an offsite radiological dose assessment code. Uncertainty in onsite dose was assessed by employing a discrete-event simulation model of repository operations in conjunction with an occupational radiological dose assessment model. Complementary cumulative distribution functions of offsite and onsite dose were used to illustrate reasonable assurance. Offsite dose analyses were performed for iodine -129, cesium-137, strontium-90, and plutonium-239. Complementary cumulative distribution functions of offsite dose were constructed; offsite dose was lognormally distributed with a two order of magnitude range. However, plutonium-239 results were not lognormally distributed and exhibited less than one order of magnitude range. Onsite dose analyses were performed for the preliminary inspection, receiving and handling, and the underground areas of the repository. Complementary cumulative distribution functions of onsite dose were constructed and exhibited less than one order of magnitude range. A preliminary sensitivity analysis of the receiving and handling areas was conducted using a regression metamodel. Sensitivity coefficients and partial correlation coefficients were used as measures of sensitivity. Model output was most sensitive to parameters related to cask handling operations. Model output showed little sensitivity to parameters related to cask inspections.

  13. Automated size-specific CT dose monitoring program: assessing variability in CT dose.

    PubMed

    Christianson, Olav; Li, Xiang; Frush, Donald; Samei, Ehsan

    2012-11-01

    The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED(adj)). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED(adj) between scanner models and across institutions. No significant difference was found between computer measurements of patient thickness and observer measurements (p = 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED(adj) that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED(adj) distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED(adj) (range: 9%-64%). Finally, a significant difference (up to 59%) in ED(adj) distributions was observed between institutions, indicating the potential for dose reduction. The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED(adj) were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

  14. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christianson, Olav; Li Xiang; Frush, Donald

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CTmore » imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.« less

  15. Sustained Neuroprotection From a Single Intravitreal Injection of PGJ2 in a Nonhuman Primate Model of Nonarteritic Anterior Ischemic Optic Neuropathy

    PubMed Central

    Miller, Neil R.; Johnson, Mary A.; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M.; Bernstein, Steven L.

    2014-01-01

    Purpose. Prostaglandin J2 (PGJ2) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ2 in a nonhuman primate model of NAION (pNAION). Methods. We assessed PGJ2 toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ2 or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ2 or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. Results. Toxicity: PGJ2 caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ2 used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ2; however, the amplitudes returned to normal in all animals within 1 week. Efficacy: In all eyes, a single IVT dose of PGJ2 administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and histological damage compared with vehicle-injected eyes (P = 0.03 for both VEP and PERG; P = 0.05 for axon counts). Conclusions. In nonhuman primates, PGJ2 administered either intravenously or intravitreally produces no permanent toxicity at even four times the dose given for neuroprotection. Additionally, a single IVT dose of PGJ2 is neuroprotective when administered up to 5 hours after induction of pNAION. PMID:25298416

  16. Role of renal function in risk assessment of target non-attainment after standard dosing of meropenem in critically ill patients: a prospective observational study.

    PubMed

    Ehmann, Lisa; Zoller, Michael; Minichmayr, Iris K; Scharf, Christina; Maier, Barbara; Schmitt, Maximilian V; Hartung, Niklas; Huisinga, Wilhelm; Vogeser, Michael; Frey, Lorenz; Zander, Johannes; Kloft, Charlotte

    2017-10-21

    Severe bacterial infections remain a major challenge in intensive care units because of their high prevalence and mortality. Adequate antibiotic exposure has been associated with clinical success in critically ill patients. The objective of this study was to investigate the target attainment of standard meropenem dosing in a heterogeneous critically ill population, to quantify the impact of the full renal function spectrum on meropenem exposure and target attainment, and ultimately to translate the findings into a tool for practical application. A prospective observational single-centre study was performed with critically ill patients with severe infections receiving standard dosing of meropenem. Serial blood samples were drawn over 4 study days to determine meropenem serum concentrations. Renal function was assessed by creatinine clearance according to the Cockcroft and Gault equation (CLCR CG ). Variability in meropenem serum concentrations was quantified at the middle and end of each monitored dosing interval. The attainment of two pharmacokinetic/pharmacodynamic targets (100%T >MIC , 50%T >4×MIC ) was evaluated for minimum inhibitory concentration (MIC) values of 2 mg/L and 8 mg/L and standard meropenem dosing (1000 mg, 30-minute infusion, every 8 h). Furthermore, we assessed the impact of CLCR CG on meropenem concentrations and target attainment and developed a tool for risk assessment of target non-attainment. Large inter- and intra-patient variability in meropenem concentrations was observed in the critically ill population (n = 48). Attainment of the target 100%T >MIC was merely 48.4% and 20.6%, given MIC values of 2 mg/L and 8 mg/L, respectively, and similar for the target 50%T >4×MIC . A hyperbolic relationship between CLCR CG (25-255 ml/minute) and meropenem serum concentrations at the end of the dosing interval (C 8h ) was derived. For infections with pathogens of MIC 2 mg/L, mild renal impairment up to augmented renal function was identified as a risk factor for target non-attainment (for MIC 8 mg/L, additionally, moderate renal impairment). The investigated standard meropenem dosing regimen appeared to result in insufficient meropenem exposure in a considerable fraction of critically ill patients. An easy- and free-to-use tool (the MeroRisk Calculator) for assessing the risk of target non-attainment for a given renal function and MIC value was developed. Clinicaltrials.gov, NCT01793012 . Registered on 24 January 2013.

  17. WE-B-207-00: CT Lung Cancer Screening Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  18. WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, C.

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  19. Sensitivity of the immature rat uterotrophic assay to mixtures of estrogens.

    PubMed Central

    Tinwell, Helen; Ashby, John

    2004-01-01

    We have evaluated whether mixtures of estrogens, present in the mix at doses that are individually inactive in the immature rat uterotrophic assay, can give a uterotrophic response. Seven chemicals were evaluated: nonylphenol, bisphenol A (BPA), methoxychlor, genistein (GEN), estradiol, diethylstilbestrol, and ethinyl estradiol. Dose responses in the uterotrophic assay were constructed for each chemical. The first series of experiments involved evaluating binary mixtures of BPA and GEN at dose levels that gave moderate uterotrophic responses when tested individually. The mixtures generally showed an intermediate or reduced uterotrophic effect compared with when the components of the mixture were tested alone at the dose used in the mixture. The next series of experiments used a multicomponent (complex) mixture of all seven chemicals evaluated at doses that gave either weakly positive or inactive uterotrophic responses when tested individually in the assay. Doses that were nominally equi-uterotrophic ranged over approximately six orders of magnitude for the seven chemicals. Doses of agents that gave a weak uterotrophic response when tested individually gave a marginally enhanced positive response in the assay when tested combined as a mixture. Doses of agents that gave a negative uterotrophic response when tested individually gave a positive response when tested as a mixture. These data indicate that a variety of different estrogen receptor (ER) agonists, present individually at subeffective doses, can act simultaneously to evoke an ER-regulated response. However, translating these findings into the process of environmental hazard assessment will be difficult. The simple addition of the observed, or predicted, activities for the components of a mixture is confirmed here to be inappropriate and to overestimate the actual effect induced by the mixture. Equally, isobole analysis is only suitable for two- or three-component mixtures, and concentration addition requires access to dose-response data and EC50 values (concentration giving 50% of the maximum response) for the individual components of the mixture--requirements that will rarely be fulfilled for complex environmental samples. Given these uncertainties, we conclude that it may be most expedient to select and bioassay whole environmental mixtures of potential concern. PMID:15064164

  20. Gamma rays induce DNA damage and oxidative stress associated with impaired growth and reproduction in the copepod Tigriopus japonicus.

    PubMed

    Han, Jeonghoon; Won, Eun-Ji; Lee, Bo-Young; Hwang, Un-Ki; Kim, Il-Chan; Yim, Joung Han; Leung, Kenneth Mei Yee; Lee, Yong Sung; Lee, Jae-Seong

    2014-07-01

    Nuclear radioisotope accidents are potentially ecologically devastating due to their impact on marine organisms. To examine the effects of exposure of a marine organism to radioisotopes, we irradiated the intertidal copepod Tigriopus japonicus with several doses of gamma radiation and analyzed the effects on mortality, fecundity, and molting by assessing antioxidant enzyme activities and gene expression patterns. No mortality was observed at 96h, even in response to exposure to a high dose (800Gy) of radiation, but mortality rate was significantly increased 120h (5 days) after exposure to 600 or 800Gy gamma ray radiation. We observed a dose-dependent reduction in fecundity of ovigerous females; even the group irradiated with 50Gy showed a significant reduction in fecundity, suggesting that gamma rays are likely to have a population level effect. In addition, we observed growth retardation, particularly at the nauplius stage, in individuals after gamma irradiation. In fact, nauplii irradiated with more than 200Gy, though able to molt to copepodite stage 1, did not develop into adults. Upon gamma radiation, T. japonicus showed a dose-dependent increase in reactive oxygen species (ROS) levels, the activities of several antioxidant enzymes, and expression of double-stranded DNA break damage genes (e.g. DNA-PK, Ku70, Ku80). At a low level (sub-lethal dose) of gamma irradiation, we found dose-dependent upregulation of p53, implying cellular damage in T. japonicus in response to sub-lethal doses of gamma irradiation, suggesting that T. japonicus is not susceptible to sub-lethal doses of gamma irradiation. Additionally, antioxidant genes, phase II enzyme (e.g. GSTs), and cellular chaperone genes (e.g. Hsps) that are involved in cellular defense mechanisms also showed the same expression patterns for sublethal doses of gamma irradiation (50-200Gy). These findings indicate that sublethal doses of gamma radiation can induce oxidative stress-mediated DNA damage and increase the expression of antioxidant enzymes and proteins with chaperone-related functions, thereby significantly affecting life history parameters such as fecundity and molting in the copepod T. japonicus. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. In vitro dermal absorption of pyrethroid pesticides in human and rat skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, Michael F., E-mail: hughes.michaelf@epa.go; Edwards, Brenda C.

    2010-07-15

    Dermal exposure to pyrethroid pesticides can occur during manufacture and application. This study examined the in vitro dermal absorption of pyrethroids using rat and human skin. Dermatomed skin from adult male Long Evans rats or human cadavers was mounted in flow-through diffusion cells, and radiolabeled bifenthrin, deltamethrin or cis-permethrin was applied in acetone to the skin. Fractions of receptor fluid were collected every 4 h. At 24 h, the skins were washed with soap and water to remove unabsorbed chemical. The skin was then solubilized. Two additional experiments were performed after washing the skin; the first was tape-stripping the skinmore » and the second was the collection of receptor fluid for an additional 24 h. Receptor fluid, skin washes, tape strips and skin were analyzed for radioactivity. For rat skin, the wash removed 53-71% of the dose and 26-43% remained in the skin. The cumulative percentage of the dose at 24 h in the receptor fluid ranged from 1 to 5%. For human skin, the wash removed 71-83% of the dose and 14-25% remained in the skin. The cumulative percentage of the dose at 24 h in the receptor fluid was 1-2%. Tape-stripping removed 50-56% and 79-95% of the dose in rat and human skin, respectively, after the wash. From 24-48 h, 1-3% and about 1% of the dose diffused into the receptor fluid of rat and human skin, respectively. The pyrethroids bifenthrin, deltamethrin and cis-permethrin penetrated rat and human skin following dermal application in vitro. However, a skin wash removed 50% or more of the dose from rat and human skin. Rat skin was more permeable to the pyrethroids than human skin. Of the dose in skin, 50% or more was removed by tape-stripping, suggesting that permeation of pyrethroids into viable tissue could be impeded. The percentage of the dose absorbed into the receptor fluid was considerably less than the dose in rat and human skin. Therefore, consideration of the skin type used and fractions analyzed are important when using in vitro dermal absorption data for risk assessment.« less

  2. Validation of calculation algorithms for organ doses in CT by measurements on a 5 year old paediatric phantom

    NASA Astrophysics Data System (ADS)

    Dabin, Jérémie; Mencarelli, Alessandra; McMillan, Dayton; Romanyukha, Anna; Struelens, Lara; Lee, Choonsik

    2016-06-01

    Many organ dose calculation tools for computed tomography (CT) scans rely on the assumptions: (1) organ doses estimated for one CT scanner can be converted into organ doses for another CT scanner using the ratio of the Computed Tomography Dose Index (CTDI) between two CT scanners; and (2) helical scans can be approximated as the summation of axial slices covering the same scan range. The current study aims to validate experimentally these two assumptions. We performed organ dose measurements in a 5 year-old physical anthropomorphic phantom for five different CT scanners from four manufacturers. Absorbed doses to 22 organs were measured using thermoluminescent dosimeters for head-to-torso scans. We then compared the measured organ doses with the values calculated from the National Cancer Institute dosimetry system for CT (NCICT) computer program, developed at the National Cancer Institute. Whereas the measured organ doses showed significant variability (coefficient of variation (CoV) up to 53% at 80 kV) across different scanner models, the CoV of organ doses normalised to CTDIvol substantially decreased (12% CoV on average at 80 kV). For most organs, the difference between measured and simulated organ doses was within  ±20% except for the bone marrow, breasts and ovaries. The discrepancies were further explained by additional Monte Carlo calculations of organ doses using a voxel phantom developed from CT images of the physical phantom. The results demonstrate that organ doses calculated for one CT scanner can be used to assess organ doses from other CT scanners with 20% uncertainty (k  =  1), for the scan settings considered in the study.

  3. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    PubMed

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  4. The role of dose rate in radiation cancer risk: evaluating the effect of dose rate at the molecular, cellular and tissue levels using key events in critical pathways following exposure to low LET radiation

    PubMed Central

    Brooks, Antone L.; Hoel, David G.; Preston, R. Julian

    2016-01-01

    Abstract Purpose: This review evaluates the role of dose rate on cell and molecular responses. It focuses on the influence of dose rate on key events in critical pathways in the development of cancer. This approach is similar to that used by the U.S. EPA and others to evaluate risk from chemicals. It provides a mechanistic method to account for the influence of the dose rate from low-LET radiation, especially in the low-dose region on cancer risk assessment. Molecular, cellular, and tissues changes are observed in many key events and change as a function of dose rate. The magnitude and direction of change can be used to help establish an appropriate dose rate effectiveness factor (DREF). Conclusions: Extensive data on key events suggest that exposure to low dose-rates are less effective in producing changes than high dose rates. Most of these data at the molecular and cellular level support a large (2–30) DREF. In addition, some evidence suggests that doses delivered at a low dose rate decrease damage to levels below that observed in the controls. However, there are some data human and mechanistic data that support a dose-rate effectiveness factor of 1. In summary, a review of the available molecular, cellular and tissue data indicates that not only is dose rate an important variable in understanding radiation risk but it also supports the selection of a DREF greater than one as currently recommended by ICRP (2007) and BEIR VII (NRC/NAS 2006). PMID:27266588

  5. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism.

    PubMed

    Schäfer, Julia Carmen; Haubenreisser, Holger; Meyer, Mathias; Grüttner, Joachim; Walter, Thomas; Borggrefe, Martin; Schoepf, Joseph U; Nance, John W; Schönberg, Stefan O; Henzler, Thomas

    2018-06-01

     To prospectively evaluate the feasibility of single contrast bolus high-pitch CT pulmonary angiography (CTPA) subsequently followed by low-dose retrospectively ECG-gated cardiac CT (4D-cCT) in patients with suspected pulmonary embolism (PE) to accurately evaluate right ventricular (RV) function.  62 patients (33 female, age 65.1 ± 17.5 years) underwent high-pitch CTPA examination with 80cc of iodinated contrast material. 5 s after the end of the high-pitch CTPA study, a low-dose retrospectively ECG-gated cardiac CT examination was automatically started. The volume CT dose index (CTDI vol) and dose length product (DLP) were recorded in all patients and the effective dose was calculated. For the assessment of image quality, attenuation was measured as Hounsfield units (HUs) within various regions of interest (ROIs). These ROIs were used to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was assessed using a five-point Likert scale. On 4D-cCT, the ejection fraction of both ventricles (RVEF, LVEF) as well as the ratio of RVEF and LVEF (RVEF/LVEF) was assessed. The statistical difference of all parameters between the PE and non-PE group was calculated.  The mean effective radiation dose was 4.22 ± 2.05 mSv. Attenuation measurements on CTPA showed the highest attenuation values in the main pulmonary artery (442.01 ± 187.64). On 4D-cCT attenuation values were highest in the descending aorta (560.59 ± 208.81). The CNR and SNR values on CTPA were highest within the main pulmonary artery (CNR = 12.43 ± 4.57; SNR = 15.14 ± 4.90). On 4D-cCT images, the highest SNR and CNR could be measured in the descending aorta (CNR = 10.26 ± 5.57; SNR = 10.86 ± 5.17). The mean LVEF was 60.73 %± 14.65 %, and the mean RVEF was 44.90 %± 9.54 %. The mean RVEF/LVEF was 0.79 ± 0.29. There was no significant difference between the PE and non-PE group for either of the parameters.  The investigated combined CTPA and 4D-cCT protocol is feasible using a single contrast bolus and allows the evaluation of RV function in patients with suspected PE. Further studies have to evaluate the additional value of this protocol regarding risk stratification in patients with PE.   · High-pitch CTPA is fast enough to leave sufficient contrast material within the heart that can be used for an additional low-dose functional cardiac CT examination.. · The tube current of the evaluated 4D-cCT is reduced over the entire cardiac cycle without any full dose peak.. · Low-dose cardiac CT subsequently performed after high-pitch CTPA allows for detailed analysis of RV function.. · Schäfer JC, Haubenreisser H, Meyer M et al. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism. Fortschr Röntgenstr 2018; 190: 542 - 550. © Georg Thieme Verlag KG Stuttgart · New York.

  6. [Monitoring medication errors in personalised dispensing using the Sentinel Surveillance System method].

    PubMed

    Pérez-Cebrián, M; Font-Noguera, I; Doménech-Moral, L; Bosó-Ribelles, V; Romero-Boyero, P; Poveda-Andrés, J L

    2011-01-01

    To assess the efficacy of a new quality control strategy based on daily randomised sampling and monitoring a Sentinel Surveillance System (SSS) medication cart, in order to identify medication errors and their origin at different levels of the process. Prospective quality control study with one year follow-up. A SSS medication cart was randomly selected once a week and double-checked before dispensing medication. Medication errors were recorded before it was taken to the relevant hospital ward. Information concerning complaints after receiving medication and 24-hour monitoring were also noted. Type and origin error data were assessed by a Unit Dose Quality Control Group, which proposed relevant improvement measures. Thirty-four SSS carts were assessed, including 5130 medication lines and 9952 dispensed doses, corresponding to 753 patients. Ninety erroneous lines (1.8%) and 142 mistaken doses (1.4%) were identified at the Pharmacy Department. The most frequent error was dose duplication (38%) and its main cause inappropriate management and forgetfulness (69%). Fifty medication complaints (6.6% of patients) were mainly due to new treatment at admission (52%), and 41 (0.8% of all medication lines), did not completely match the prescription (0.6% lines) as recorded by the Pharmacy Department. Thirty-seven (4.9% of patients) medication complaints due to changes at admission and 32 matching errors (0.6% medication lines) were recorded. The main cause also was inappropriate management and forgetfulness (24%). The simultaneous recording of incidences due to complaints and new medication coincided in 33.3%. In addition, 433 (4.3%) of dispensed doses were returned to the Pharmacy Department. After the Unit Dose Quality Control Group conducted their feedback analysis, 64 improvement measures for Pharmacy Department nurses, 37 for pharmacists, and 24 for the hospital ward were introduced. The SSS programme has proven to be useful as a quality control strategy to identify Unit Dose Distribution System errors at initial, intermediate and final stages of the process, improving the involvement of the Pharmacy Department and ward nurses. Copyright © 2009 SEFH. Published by Elsevier Espana. All rights reserved.

  7. MDCT of acute pancreatitis: Intraindividual comparison of single-phase versus dual-phase MDCT for initial assessment of acute pancreatitis using different CT scoring systems.

    PubMed

    Avanesov, Maxim; Weinrich, Julius M; Kraus, Thomas; Derlin, Thorsten; Adam, Gerhard; Yamamura, Jin; Karul, Murat

    2016-11-01

    The purpose of the retrospective study was to evaluate the additional value of dual-phase multidetector computed tomography (MDCT) protocols over a single-phase protocol on initial MDCT in patients with acute pancreatitis using three CT-based pancreatitis severity scores with regard to radiation dose. In this retrospective, IRB approved study MDCT was performed in 102 consecutive patients (73 males; 55years, IQR48-64) with acute pancreatitis. Inclusion criteria were CT findings of interstitial edematous pancreatitis (IP) or necrotizing pancreatitis (NP) and a contrast-enhanced dual-phase (arterial phase and portal-venous phase) abdominal CT performed at ≥72h after onset of symptoms. The severity of pancreatic and extrapancreatic changes was independently assessed by 2 observers using 3 validated CT-based scoring systems (CTSI, mCTSI, EPIC). All scores were applied to arterial phase and portal venous phase scans and compared to score results of portal venous phase scans, assessed ≥14days after initial evaluation. For effective dose estimation, volume CT dose index (CTDIvol) and dose length product (DLP) were recorded in all examinations. In neither of the CT severity scores a significant difference was observed after application of a dual-phase protocol compared with a single-phase protocol (IP: CTSI: 2.7 vs. 2.5, p=0.25; mCTSI: 4.0 vs. 4.0, p=0.10; EPIC: 2.0 vs. 2.0, p=0.41; NP: CTSI: 8.0 vs. 7.0, p=0.64; mCTSI: 8.0 vs. 8.0, p=0.10; EPIC: 3.0 vs. 3.0, p=0.06). The application of a single-phase CT protocol was associated with a median effective dose reduction of 36% (mean dose reduction 31%) compared to a dual-phase CT scan. An initial dual-phase abdominal CT after ≥72h after onset of symptoms of acute pancreatitis was not superior to a single-phase protocol for evaluation of the severity of pancreatic and extrapancreatic changes. However, the effective radiation dose may be reduced by 36% using a single-phase protocol. Copyright © 2016. Published by Elsevier Ireland Ltd.

  8. Safety of the Up-titration of Nifedipine GITS and Valsartan or Low-dose Combination in Uncontrolled Hypertension: the FOCUS Study.

    PubMed

    Park, Jeong Bae; Shin, Joon-Han; Kim, Dong-Soo; Youn, Ho-Joong; Park, Seung Woo; Shim, Wan Joo; Park, Chang Gyu; Kim, Dong-Woon; Lee, Hae-Young; Choi, Dong-Ju; Rim, Se-Joong; Lee, Sung-Yun; Kim, Ju-Han

    2016-04-01

    Doubling the dose of antihypertensive drugs is necessary to manage hypertension in patients whose disease is uncontrolled. However, this strategy can result in safety issues. This study compared the safety and efficacy of up-titration of the nifedipine gastrointestinal therapeutic system (GITS) with up-titration of valsartan monotherapy; these were also compared with low-dose combinations of the two therapies. This prospective, open-label, randomized, active-controlled, multicenter study lasted 8 weeks. If patients did not meet the target blood pressure (BP) after 4 weeks of treatment with low-dose monotherapy, they were randomized to up-titration of the nifedipine GITS dose from 30 mg (N30) to 60 mg or valsartan from 80 mg to 160 mg or they were randomized to receive a low-dose combination of N30 and valsartan 80 mg for another 4 weeks. BP variability was assessed by using the SD or the %CV of the short-term BP measured at clinic. Of the 391 patients (20~70 years with stage II or higher hypertension) screened for study inclusion, 362 patients who had 3 BP measurements were enrolled. The reduction in the mean systolic/diastolic BP from baseline to week 4 was similar in both low-dose monotherapy groups with either N30 or valsartan 80 mg. BP variability (SD) was unchanged with either therapy, but the %CV was slightly increased in the N30 group. There was no significant difference in BP variability either in SD or %CV between responders and nonresponders to each monotherapy despite the significant difference in the mean BP changes. The up-titration effect of nifedipine GTS from 30 to 60 mg exhibited an additional BP reduction, but this effect was not shown in the up-titration of valsartan from 80 to 160 mg. Although the difference in BP was obvious between high-dose nifedipine GTS and valsartan, the BP variability was unchanged between the 2 drugs and was similar to the low-dose combinations. There was a low rate of adverse events in all treatment groups. In addition, escalating the dose of either nifedipine GITS or valsartan revealed a similar occurrence of adverse effects with low-dose monotherapy or the low-dose combination. Compared with up-titration of the angiotensin receptor blocker valsartan, up-titration of the calcium channel blocker nifedipine GITS provided no additional increased safety concerns and revealed better mean reductions in BP without affecting short-term BP variability. ClinicalTrials.gov identifier: NCT01071122. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  9. An Overview of NASA's Risk of Cardiovascular Disease from Radiation Exposure

    NASA Technical Reports Server (NTRS)

    Patel, Zarana S.; Huff, Janice L.; Simonsen, Lisa C.

    2015-01-01

    The association between high doses of radiation exposure and cardiovascular damage is well established. Patients that have undergone radiotherapy for primary cancers of the head and neck and mediastinal regions have shown increased risk of heart and vascular damage and long-term development of radiation-induced heart disease [1]. In addition, recent meta-analyses of epidemiological data from atomic bomb survivors and nuclear industry workers has also shown that acute and chronic radiation exposures is strongly correlated with an increased risk of circulatory disease at doses above 0.5 Sv [2]. However, these analyses are confounded for lower doses by lifestyle factors, such as drinking, smoking, and obesity. The types of radiation found in the space environment are significantly more damaging than those found on Earth and include galactic cosmic radiation (GCR), solar particle events (SPEs), and trapped protons and electrons. In addition to the low-LET data, only a few studies have examined the effects of heavy ion radiation on atherosclerosis, and at lower, space-relevant doses, the association between exposure and cardiovascular pathology is more varied and unclear. Understanding the qualitative differences in biological responses produced by GCR compared to Earth-based radiation is a major focus of space radiation research and is imperative for accurate risk assessment for long duration space missions. Other knowledge gaps for the risk of radiation-induced cardiovascular disease include the existence of a dose threshold, low dose rate effects, and potential synergies with other spaceflight stressors. The Space Radiation Program Element within NASA's Human Research Program (HRP) is managing the research and risk mitigation strategies for these knowledge gaps. In this presentation, we will review the evidence and present an overview of the HRP Risk of Cardiovascular Disease and Other Degenerative Tissue Effects from Radiation Exposure.

  10. Modulation of cannabinoid signaling by amygdala α2-adrenergic system in fear conditioning.

    PubMed

    Nasehi, Mohammad; Zamanparvar, Majid; Ebrahimi-Ghiri, Mohaddeseh; Zarrindast, Mohammad-Reza

    2016-03-01

    The noradrenergic system plays a critical role in the modulation of emotional state, primarily related to anxiety, arousal, and stress. Growing evidence suggests that the endocannabinoid system mediates stress responses and emotional homeostasis, in part, by targeting noradrenergic circuits. In addition, there is an interaction between the cannabinoid and noradrenergic system that has significant functional and behavioral implications. Considering the importance of these systems in forming memories for fearful events, we have investigated the involvement of basolateral amygdala (BLA) α2-adrenoceptors on ACPA (as selective cannabinoid CB1 agonist)-induced inhibition of the acquisition of contextual and auditory conditioned fear. A contextual and auditory fear conditioning apparatus for assess fear memory in adult male NMRI mice was used. Pre-training, intraperitoneal administration of ACPA decreased the percentage freezing time in contextual (at doses of 0.05 and 0.1mg/kg) and auditory (at dose of 0.1 mg/kg) in the fear conditioning task, indicating memory acquisition deficit. The same result was observed with intra-BLA microinjection of clonidine (0.001-0.5 μg/mouse, for both memories), as α2-adrenoceptor agonist and yohimbine (at doses of 0.005 and 0.05 for contextual and at dose of 0.05 μg/mouse for auditory fear memory), as α2-adrenoceptor antagonist. In addition, intra-BLA microinjection of clonidine (0.0005 μg/mouse) did not alter ACPA response in both conditions, while the same dose of yohimbine potentiated ACPA response at the lower dose on contextual fear memory. It is concluded that BLA α2-adrenergic receptors may be involved in context- but not tone-dependent fear memory impairment induced by activation of CB1 receptors. Copyright © 2015. Published by Elsevier B.V.

  11. Quantitative Proteomic Profiling of Low Dose Ionizing Radiation Effects in a Human Skin Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hengel, Shawna; Aldrich, Joshua T.; Waters, Katrina M.

    2014-07-29

    To assess molecular responses to low doses of radiation that may be encountered during medical diagnostic procedures, nuclear accidents, or terrorist acts, a quantitative global proteomic approach was used to identify protein alterations in a reconstituted human skin tissue treated with 10 cGy of ionizing radiation. Subcellular fractionation was employed to remove highly abundant structural proteins and provide insight on radiation induced alterations in protein abundance and localization. In addition, peptides were post-fractionated using high resolution 2-dimensional liquid chromatography to increase the dynamic range of detection of protein abundance and translocation changes. Quantitative data was obtained by labeling peptides withmore » 8-plex isobaric iTRAQ tags. A total of 207 proteins were detected with statistically significant alterations in abundance and/or subcellular localization compared to sham irradiated tissues. Bioinformatics analysis of the data indicated that the top canonical pathways affected by low dose radiation are related to cellular metabolism. Among the proteins showing alterations in abundance, localization and proteolytic processing was the skin barrier protein filaggrin which is consistent with our previous observation that ionizing radiation alters profilaggrin processing with potential effects on skin barrier functions. In addition, a large number of proteases and protease regulators were affected by low dose radiation exposure indicating that altered proteolytic activity may be a hallmark of low dose radiation exposure. While several studies have demonstrated altered transcriptional regulation occurs following low dose radiation exposures, the data presented here indicates post-transcriptional regulation of protein abundance, localization, and proteolytic processing play an important role in regulating radiation responses in complex human tissues.« less

  12. Single dose oral paracetamol (acetaminophen) with codeine for postoperative pain in adults

    PubMed Central

    Toms, Laurence; Derry, Sheena; Moore, R Andrew; McQuay, Henry J

    2014-01-01

    Background This is an updated version of the Cochrane review published in Issue 4, 1998. Combining drugs from different classes with different modes of action may offer opportunity to optimise efficacy and tolerability, using lower doses of each drug to achieve the same degree of pain relief. Previously we concluded that addition of codeine to paracetamol provided additional pain relief, but at expense of additional adverse events. New studies have been published since. This review sought to evaluate efficacy and safety of paracetamol plus codeine using current data, and compare findings with other analgesics evaluated similarly. Objectives Assess efficacy of single dose oral paracetamol plus codeine in acute postoperative pain, increase in efficacy due to the codeine component, and associated adverse events. Search methods We searched CENTRAL, MEDLINE, EMBASE, the Oxford Pain Relief Database in October 2008 for this update. Selection criteria Randomised, double-blind, placebo-controlled trials of paracetamol plus codeine, compared with placebo or the same dose of paracetamol alone, for relief of acute postoperative pain in adults. Data collection and analysis Two authors assessed trial quality and extracted data. The area under the “pain relief versus time” curve was used to derive proportion of participants with paracetamol plus codeine and placebo or paracetamol alone experiencing least 50% pain relief over four-to-six hours, using validated equations. Number-needed-to-treat-to-benefit (NNT) was calculated using 95% confidence intervals (CIs). Proportion of participants using rescue analgesia over a specified time period, and time to use of rescue analgesia, were sought as additional measures of efficacy. Information on adverse events and withdrawals were collected. Main results Twenty-six studies, with 2295 participants, were included comparing paracetamol plus codeine with placebo. Significant dose response was seen for the outcome of at least 50% pain relief over four-to-six hours, with NNTs of 2.2 (95% CI 1.8 to 2.9) for 800 to 1000 mg paracetamol plus 60 mg codeine, 3.9 (2.9 to 4.5) for 600 to 650 mg paracetamol plus 60 mg codeine, and 6.9 (4.8 to 12) for 300 mg paracetamol plus 30 mg codeine. Time to use of rescue medication was over four hours with paracetamol plus codeine and two hours with placebo. The NNT to prevent remedication was 5.6 (4.0 to 9.0) for 600 mg paracetamol plus 60 mg codeine over four to six hours. Adverse events increased of mainly mild to moderate severity with paracetamol plus codeine than placebo. Fourteen studies, with 926 participants, were included in the comparison of paracetamol plus codeine with the same dose of paracetamol alone. Addition of codeine increased proportion of participants achieving at least 50% pain relief over four-to-six hours by 10 to 15%, increased time to use of rescue medication by about one hour, and reduced proportion of participants needing rescue medication by about 15% (NNT to prevent remedication 6.9 (4.2 to 19). Adverse events were mainly mild to moderate in severity and incidence did not differ between groups. Authors’ conclusions This update confirms previous findings that combining paracetamol with codeine provided clinically useful levels of pain relief in about 50% of patients with moderate to severe postoperative pain, compared with under 20% with placebo. New information for remedication shows that the combination extended the duration of analgesia by about one hour compared to treatment with the same dose of paracetamol alone. At higher doses, more participants experienced adequate pain relief, but the amount of information available for the 1000 mg paracetamol plus 60 mg codeine dose was small, and based on limited information. PMID:19160199

  13. A Mode-of-Action Approach for the Identification of Genotoxic Carcinogens

    PubMed Central

    Hernández, Lya G.; van Benthem, Jan; Johnson, George E.

    2013-01-01

    Distinguishing between clastogens and aneugens is vital in cancer risk assessment because the default assumption is that clastogens and aneugens have linear and non-linear dose-response curves, respectively. Any observed non-linearity must be supported by mode of action (MOA) analyses where biological mechanisms are linked with dose-response evaluations. For aneugens, the MOA has been well characterised as disruptors of mitotic machinery where chromosome loss via micronuclei (MN) formation is an accepted endpoint used in risk assessment. In this study we performed the cytokinesis-block micronucleus assay and immunofluorescence mitotic machinery visualisation in human lymphoblastoid (AHH-1) and Chinese Hamster fibroblast (V79) cell lines after treatment with the aneugen 17-β-oestradiol (E2). Results were compared to previously published data on bisphenol-A (BPA) and Rotenone data. Two concentration-response approaches (the threshold-[Td] and benchmark-dose [BMD] approaches) were applied to derive a point of departure (POD) for in vitro MN induction. BMDs were also derived from the most sensitive carcinogenic endpoint. Ranking comparisons of the PODs from the in vitro MN and the carcinogenicity studies demonstrated a link between these two endpoints for BPA, E2 and Rotenone. This analysis was extended to include 5 additional aneugens, 5 clastogens and 3 mutagens and further concentration and dose-response correlations were observed between PODs from the in vitro MN and carcinogenicity. This approach is promising and may be further extended to other genotoxic carcinogens, where MOA and quantitative information from the in vitro MN studies could be used in a quantitative manner to further inform cancer risk assessment. PMID:23675539

  14. Model-based analysis of thromboxane B₂ and prostaglandin E₂ as biomarkers in the safety evaluation of naproxen.

    PubMed

    Sahota, Tarjinder; Sanderson, Ian; Danhof, Meindert; Della Pasqua, Oscar

    2014-08-01

    The assessment of safety in traditional toxicology protocols relies on evidence arising from observed adverse events (AEs) in animals and on establishing their correlation with different measures of drug exposure (e.g., Cmax and AUC). Such correlations, however, ignore the role of biomarkers, which can provide further insight into the underlying pharmacological mechanisms. Here we use naproxen as a paradigm drug to explore the feasibility of a biomarker-guided approach for the prediction of AEs in humans. A standard toxicology protocol was set up for the evaluation of effects of naproxen in rat, in which four doses were tested (7.5, 15, 40 and 80 mg/kg). In addition to sparse blood sampling for the assessment of exposure, thromboxane B₂ and prostaglandin E₂ were also collected in satellite groups. Nonlinear mixed effects modelling was used to evaluate the predictive performance of the approach. A one-compartmental model with first order absorption was found to best describe the pharmacokinetics of naproxen. A nonlinear relationship between dose and bioavailability was observed which leads to a less than proportional increase in naproxen concentrations with increasing doses. The pharmacodynamics of TXB₂ and PGE₂ was described by direct inhibition models with maximum pharmacological effects achieved at doses >7.5 mg/kg. The predicted PKPD relationship in humans was within 10-fold of the values previously published. Moreover, our results indicate that biomarkers can be used to assess interspecies differences in PKPD and extrapolated data from animals to humans. Biomarker sampling should be used systematically in general toxicity studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Bioequivalence assessment of rifampicin, isoniazid and pyrazinamide in a fixed dose combination of rifampicin, isoniazid, pyrazinamide and ethambutol vs. separate formulations.

    PubMed

    Agrawal, S; Singh, I; Kaur, K J; Bhade, S R; Kaul, C L; Panchagnula, R

    2002-10-01

    Depending on the patient category, tuberculosis requires treatment with 3 to 5 drugs which means that patient's compliance to therapy may not be optimal. To increase patient's adherence to treatment schedules, these drugs can be given as single drug preparations or fixed dose combinations (FDCs) of 2 or more drugs in a single formulation. However, an important issue associated with a rifampicin-containing FDC is its quality. Hence, to avoid spurious formulations entering the market, the World Health Organization and the International Union Against Tuberculosis and Lung Disease have recommended FDCs only of proven bioavailability. In this study, the relative bioavailability of rifampicin, isoniazid and pyrazinamide was assessed in a group of 14 healthy male subjects using the FDC tablet containing 4 drugs versus separate formulations at the same dose levels. The study was designed as an open, crossover trial. A total of 9 blood samples were collected over a period of 24 h. The concentration of rifampicin, its main metabolite desacetyl rifampicin, isoniazid and pyrazinamide in plasma were assessed using HPLC analysis. The pharmacokinetic parameters AUC(0-24) and Cmax were subjected to parametric and non-parametric statistical tests at 90% confidence interval. In addition, time to reach peak concentration (tmax), elimination rate constant (Kel) and terminal elimination half-life (t1/2) for each drug were also calculated. It was concluded that the FDC tablet containing 4 drugs is bioequivalent to separate rifampicin, isoniazid and pyrazinamide formulations at the same dose levels.

  16. Poor Immune Responses to a Birth Dose of Diphtheria, Tetanus, and Acellular Pertussis Vaccine

    PubMed Central

    Halasa, Natasha B.; O’Shea, Alice; Shi, Jian R.; Lafleur, Bonnie J.; Edwards, Kathryn M.

    2013-01-01

    Objectives To evaluate the safety and immunogenicity of an additional birth dose of diphtheria, tetanus, and acellular pertussis vaccine (DTaP). Study design Fifty infants between 2 to 14 days of age were randomly assigned to receive either DTaP and hepatitis B vaccines (experimental) or hepatitis B alone (control) at birth. At 2, 4, 6, and 17 months of age, DTaP and routine vaccines were administered to both groups. Safety data were collected after each dose, and sera were obtained at birth, 6, 7, 17, and 18 months. Immune responses to pertussis toxin, filamentous hemagglutinin, pertactin, and fimbriae were measured by enzyme-linked immunosorbent assay; responses to other vaccines were assessed. Results No differences were seen between the 2 groups in either local or systemic reactions; all vaccines were well tolerated. Compared with the control group, infants in the experimental group demonstrated significantly lower geometric mean antibody concentrations for pertussis toxin and pertactin 6, 7, and 18 months, for fimbrae at 6, 7, 17, and 18 months, and for FHA at 18 months, and lower geometric mean antibody concentrations for diphtheria at 7 months. Immune responses to all other vaccine antigens were comparable. Conclusion Administration of an additional dose of DTaP at birth was safe but was associated with a significantly lower response to diphtheria and 3 of 4 pertussis antigens compared with controls. PMID:18534242

  17. Safety and tolerability of the γ-secretase inhibitor avagacestat in a phase 2 study of mild to moderate Alzheimer disease.

    PubMed

    Coric, Vladimir; van Dyck, Christopher H; Salloway, Stephen; Andreasen, Niels; Brody, Mark; Richter, Ralph W; Soininen, Hilkka; Thein, Stephen; Shiovitz, Thomas; Pilcher, Gary; Colby, Susan; Rollin, Linda; Dockens, Randy; Pachai, Chahin; Portelius, Erik; Andreasson, Ulf; Blennow, Kaj; Soares, Holly; Albright, Charles; Feldman, Howard H; Berman, Robert M

    2012-11-01

    To assess the safety, tolerability, and pharmacokinetic and pharmacodynamic effects of the -secretase inhibitor avagacestat in patients with mild to moderate Alzheimer disease (AD). Randomized, double-blind, placebo-controlled,24-week phase 2 study. Global, multicenter trial. A total of 209 outpatients with mild to moderate AD were randomized into the double-blind treatment phase. The median age of the patients was 75 years,58.9% were APOE ε4 carriers, and baseline measures of disease severity were similar among groups. Avagacestat, 25, 50, 100, or 125 mg daily,or placebo administered orally daily. Safety and tolerability of avagacestat. Discontinuation rates for the 25-mg and 50-mg doses of avagacestat were comparable with placebo but were higher in the 100-mg and 125-mg dose groups.Trends for worsening cognition, as measured by change from baseline Alzheimer Disease Assessment Scale cognitive subscale score, were observed in the 100-mg and125-mg dose groups. Treatment-emergent serious adverse events were similar across placebo and treatment groups. The most common reason for discontinuation was adverse events, predominantly gastrointestinal anddermatologic. Other adverse events occurring more frequentlyin patients undergoing treatment included reversibleglycosuria (without associated serum glucose changes), nonmelanoma skin cancer, and asymptomaticmagnetic resonance imaging findings. Exploratory cerebrospinal fluid amyloid isoforms and tau biomarker analysis demonstrated dose-dependent but not statistically significant reductions in a small subset of patients. Avagacestat dosed at 25 and 50 mg daily was relatively well tolerated and had low discontinuation rates. The 100-mg and 125-mg dose arms were poorly tolerated with trends for cognitive worsening. Exploratory cerebrospinal fluid biomarker substudies provide preliminary support for -secretase target engagement,but additional studies are warranted to better characterize pharmacodynamic effects at the 25- and 50-mg doses.This study establishes an acceptable safety and tolerability dose range for future avagacestat studies in AD. clinicaltrials.gov Identifier: NCT00810147

  18. Variability of methacholine bronchoprovocation and the effect of inhaled corticosteroids in mild asthma

    PubMed Central

    Sumino, Kaharu; Sugar, Elizabeth A.; Irvin, Charles G.; Kaminsky, David A.; Shade, Dave; Wei, Christine Y.; Holbrook, Janet T.; Wise, Robert A.; Castro, Mario

    2014-01-01

    Background The methacholine challenge test quantifies airway hyper-responsiveness, which is measured by the provocative concentration of methacholine causing a 20% decrease in forced expiration volume in 1 second (PC20). The dose–response effect of inhaled corticosteroids (ICS) on PC20 has been inconsistent and within-patient variability of PC20 is not well established. Objectives To determine the effect of high- vs low-dose ICS on PC20 and within-patient variability in those with repeated measurements of PC20. Methods A randomized, double-masked, crossover trial was conducted in patients with asthma on controller medications with PC20 of 8 mg/mL or lower (n = 64) to evaluate the effect of high-dose (1,000 μg/d) vs low-dose (250 μg/d) fluticasone for 4 weeks on PC20. In addition, the variability of PC20 was assessed in participants who underwent 2 or 3 PC20 measurements on the same dose of ICS (n = 27) over a 4-week interval. Results Because there was a significant period effect, dose comparison of the change in PC20 was assessed in the first treatment period. There was no significant difference in the change in PC20 for high- vs low-dose ICS (39% vs 30% increase, respectively; P = .87). The within- and between-participant variances for log PC20 were 0.84 and 0.96, respectively, with an intra-class correlation of 0.53, and 37% of participants had more than 2 doubling dose changes in PC20 in those with repeated measurements. Conclusion The effect of ICS on PC20 is not dose dependent at fluticasone levels of 250 and 1,000 μg/d. Interpersonal variability for PC20 is large. A lack of precise measurements should be taken into account when interpreting any change in PC20. PMID:24507830

  19. Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yim, Jackie; Suttie, Clare; Bromley, Regina

    We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with themore » 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.« less

  20. SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Held, M; Morin, O; Pouliot, J

    2014-06-01

    Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgentmore » and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.« less

  1. Assessment of natural and artificial radioactivity levels and radiation hazards and their relation to heavy metals in the industrial area of Port Said city, Egypt.

    PubMed

    Attia, T E; Shendi, E H; Shehata, M A

    2015-02-01

    A detailed gamma ray spectrometry survey was carried out to make an action in environmental impact assessment of urbanization and industrialization on Port Said city, Egypt. The concentrations of the measured radioelements U-238, Th-232 in ppm, and K-40 %, in addition to the total counts of three selected randomly dumping sites (A, B, and C) were mapped. The concentration maps represent a base line for the radioactivity in the study area in order to detect any future radioactive contamination. These concentrations are ranging between 0.2 and 21 ppm for U-238 and 0.01 to 13.4 ppm for Th-232 as well as 0.15 to 3.8 % for K-40, whereas the total count values range from 8.7 to 123.6 uR. Moreover, the dose rate was mapped using the same spectrometer and survey parameters in order to assess the radiological effect of these radioelements. The dose rate values range from 0.12 to 1.61 mSv/year. Eighteen soil samples were collected from the sites with high radioelement concentrations and dose rates to determine the activity concentrations of Ra-226, Th-232, and K-40 using HPGe spectrometer. The activity concentrations of Ra-226, Th-232, and K-40 in the measured samples range from 18.03 to 398.66 Bq kg(-1), 5.28 to 75.7 Bq kg(-1), and 3,237.88 to 583.12 Bq kg(-1), respectively. In addition to analyze heavy metal for two high reading samples (a 1 and a 10) which give concentrations of Cd and Zn elements (a 1 40 ppm and a 10 42 ppm) and (a 1 0.90 ppm and a 10 0.97 ppm), respectively, that are in the range of phosphate fertilizer products that suggested a dumped man-made waste in site A. All indicate that the measured values for the soil samples in the two sites of three falls within the world ranges of soil in areas with normal levels of radioactivity, while site A shows a potential radiological risk for human beings, and it is important to carry out dose assessment program with a specifically detailed monitoring program periodically.

  2. Benefits of High-dose Steroid + Hespander + Mannitol Administration in the Treatment of Bell's Palsy.

    PubMed

    Furukawa, Takatoshi; Abe, Yasuhiro; Ito, Tsukasa; Kubota, Toshinori; Kakehata, Seiji

    2017-02-01

    Large-scale investigations have not been recently conducted on the efficacy of high-dose steroid administration of prednisolone (PSL) for Bell's palsy. We compared treatment results between normal-dose steroid (PSL 60 mg/d) and high-dose steroid (PSL 200 mg/d) + Hespander + Mannitol administration. We also investigated the recovery rate for antiviral agents. Retrospective case review. Tertiary referral center. A total of 675 patients with Bell's palsy who had grade V and grade VI on the House-Brackmann (HB) scale were treated in our department between 1995 and 2014. These patients could be divided into a normal-dose group and high-dose group. We separately assessed treatment outcomes for HB grade V patients and HB grade VI patients. Logistic regression analysis was also performed to investigate factors that can impact treatment outcomes, i.e., sex, age, days to start of treatment, PSL dosage, and antiviral drug administration. Recovery rates were significantly better in the high-dose steroid + Hespander + Mannitol group in comparison with the normal-dose steroid group for HB grade V (100% versus 77.7%) and HB grade VI (92.5% versus 68.2%). Additional effects of antiviral agents were only shown in the normal-dose group. Significant factors for treatment outcomes were PSL 200 mg/d administration and early initiation of treatment. Insignificant factors were sex, age, and the antiviral agent. We showed the high-dose steroid + Hespander + Mannitol administration produced significantly better outcomes than normal-dose steroid administration in the treatment of patients with Bell's palsy.

  3. Dose assessment in environmental radiological protection: State of the art and perspectives.

    PubMed

    Stark, Karolina; Goméz-Ros, José M; Vives I Batlle, Jordi; Lindbo Hansen, Elisabeth; Beaugelin-Seiller, Karine; Kapustka, Lawrence A; Wood, Michael D; Bradshaw, Clare; Real, Almudena; McGuire, Corynne; Hinton, Thomas G

    2017-09-01

    Exposure to radiation is a potential hazard to humans and the environment. The Fukushima accident reminded the world of the importance of a reliable risk management system that incorporates the dose received from radiation exposures. The dose to humans from exposure to radiation can be quantified using a well-defined system; its environmental equivalent, however, is still in a developmental state. Additionally, the results of several papers published over the last decade have been criticized because of poor dosimetry. Therefore, a workshop on environmental dosimetry was organized by the STAR (Strategy for Allied Radioecology) Network of Excellence to review the state of the art in environmental dosimetry and prioritize areas of methodological and guidance development. Herein, we report the key findings from that international workshop, summarise parameters that affect the dose animals and plants receive when exposed to radiation, and identify further research needs. Current dosimetry practices for determining environmental protection are based on simple screening dose assessments using knowledge of fundamental radiation physics, source-target geometry relationships, the influence of organism shape and size, and knowledge of how radionuclide distributions in the body and in the soil profile alter dose. In screening model calculations that estimate whole-body dose to biota the shapes of organisms are simply represented as ellipsoids, while recently developed complex voxel phantom models allow organ-specific dose estimates. We identified several research and guidance development priorities for dosimetry. For external exposures, the uncertainty in dose estimates due to spatially heterogeneous distributions of radionuclide contamination is currently being evaluated. Guidance is needed on the level of dosimetry that is required when screening benchmarks are exceeded and how to report exposure in dose-effect studies, including quantification of uncertainties. Further research is needed to establish whether and how dosimetry should account for differences in tissue physiology, organism life stages, seasonal variability (in ecology, physiology and radiation field), species life span, and the proportion of a population that is actually exposed. We contend that, although major advances have recently been made in environmental radiation protection, substantive improvements are required to reduce uncertainties and increase the reliability of environmental dosimetry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy.

    PubMed

    Oechsner, Markus; Odersky, Leonhard; Berndt, Johannes; Combs, Stephanie Elisabeth; Wilkens, Jan Jakob; Duma, Marciana Nona

    2015-12-01

    The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on these CT datasets were determined. Twenty SBRT patients, ten lung cases and ten liver cases, were retrospectively selected for this study. Treatment plans were optimized on average intensity projection (AIP) CTs using 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT). Afterwards, the plans were copied to the planning CTs (PCT), maximum intensity projection (MIP) and mid-ventilation (MidV) CT datasets and dose was recalculated keeping all beam parameters and monitor units unchanged. Ipsilateral lung and liver volumes and dosimetric parameters for PTV (Dmean, D2, D98, D95), ipsilateral lung and liver (Dmean, V30, V20, V10) were determined and statistically analysed using Wilcoxon test. Significant but small mean differences were found for PTV dose between the CTs (lung SBRT: ≤2.5 %; liver SBRT: ≤1.6 %). MIPs achieved the smallest lung and the largest liver volumes. OAR mean doses in MIP plans were distinctly smaller than in the other CT datasets. Furthermore, overlapping of tumors with the diaphragm results in underestimated ipsilateral lung dose in MIP plans. Best agreement was found between AIP and MidV (lung SBRT). Overall, differences in liver SBRT were smaller than in lung SBRT and VMAT plans achieved slightly smaller differences than 3D-CRT plans. Only small differences were found for PTV parameters between the four CT datasets. Larger differences occurred for the doses to organs at risk (ipsilateral lung, liver) especially for MIP plans. No relevant differences were observed between 3D-CRT or VMAT plans. MIP CTs are not appropriate for OAR dose assessment. PCT, AIP and MidV resulted in similar doses. If a 4DCT is acquired PCT can be omitted using AIP or MidV for treatment planning.

  5. Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose.

    PubMed

    May, Matthias S; Kramer, Manuel R; Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Saake, Marc; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2014-09-01

    Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.

  6. Evaluation of developmental toxicity studies of glyphosate with attention to cardiovascular development.

    PubMed

    Kimmel, Gary L; Kimmel, Carole A; Williams, Amy L; DeSesso, John M

    2013-02-01

    The herbicide glyphosate has undergone multiple safety tests for developmental toxicity in rats and rabbits. The European Commission's 2002 review of available glyphosate data discusses specific heart defects observed in several individual rabbit developmental toxicity studies, but describes the evidence for a potential causal relationship as equivocal. The present assessment was undertaken to analyze the current body of information generated from seven unpublished rabbit studies in order to determine if glyphosate poses a risk for cardiovascular malformations. In addition, the results of six unpublished developmental toxicity studies in rats were considered. Five of the seven rabbit studies (dose range: 10-500 mg/kg/day) were GLP- and testing guideline-compliant for the era in which the studies were performed; a sixth study predated testing and GLP guidelines, but generally adhered to these principles. The seventh study was judged inadequate. In each of the adequate studies, offspring effects occurred only at doses that also caused maternal toxicity. An integrated evaluation of the six adequate studies, using conservative assumptions, demonstrated that neither the overall malformation rate nor the incidence of cardiovascular malformations increased with dose up to the point where severe maternal toxicity was observed (generally ≥150 mg/kg/day). Random occurrences of cardiovascular malformations were observed across all dose groups (including controls) and did not exhibit a dose-response relationship. In the six rat studies (dose range: 30-3500 mg/kg/day), a low incidence of sporadic cardiovascular malformations was reported that was clearly not related to treatment. In summary, assessment of the entire body of the developmental toxicity data reviewed fails to support a potential risk for increased cardiovascular defects as a result of glyphosate exposure during pregnancy.

  7. A Web-based Tool to Aid the Identification of Chemicals Potentially Posing a Health Risk through Percutaneous Exposure.

    PubMed

    Gorman Ng, Melanie; Milon, Antoine; Vernez, David; Lavoué, Jérôme

    2016-04-01

    Occupational hygiene practitioners typically assess the risk posed by occupational exposure by comparing exposure measurements to regulatory occupational exposure limits (OELs). In most jurisdictions, OELs are only available for exposure by the inhalation pathway. Skin notations are used to indicate substances for which dermal exposure may lead to health effects. However, these notations are either present or absent and provide no indication of acceptable levels of exposure. Furthermore, the methodology and framework for assigning skin notation differ widely across jurisdictions resulting in inconsistencies in the substances that carry notations. The UPERCUT tool was developed in response to these limitations. It helps occupational health stakeholders to assess the hazard associated with dermal exposure to chemicals. UPERCUT integrates dermal quantitative structure-activity relationships (QSARs) and toxicological data to provide users with a skin hazard index called the dermal hazard ratio (DHR) for the substance and scenario of interest. The DHR is the ratio between the estimated 'received' dose and the 'acceptable' dose. The 'received' dose is estimated using physico-chemical data and information on the exposure scenario provided by the user (body parts exposure and exposure duration), and the 'acceptable' dose is estimated using inhalation OELs and toxicological data. The uncertainty surrounding the DHR is estimated with Monte Carlo simulation. Additional information on the selected substances includes intrinsic skin permeation potential of the substance and the existence of skin notations. UPERCUT is the only available tool that estimates the absorbed dose and compares this to an acceptable dose. In the absence of dermal OELs it provides a systematic and simple approach for screening dermal exposure scenarios for 1686 substances. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  8. Changes in balance, functional performance and fall risk following whole body vibration training and vitamin D supplementation in institutionalized elderly women. A 6 month randomized controlled trial.

    PubMed

    Bogaerts, An; Delecluse, Christophe; Boonen, Steven; Claessens, Albrecht L; Milisen, Koen; Verschueren, Sabine M P

    2011-03-01

    Falls in the elderly constitute a growing public health problem. This randomized controlled trial investigated the potential benefit of 6 months of whole body vibration (WBV) training and/or vitamin D supplementation on balance, functionality and estimated fall risk in institutionalized elderly women. A total of 113 women (mean age: 79.6) were randomly assigned to either a WBV or a no-training group, receiving either a conventional dose (880 IU/d) or a high dose (1600 IU/d) of vitamin D3. The WBV group performed exercises on a vibration platform 3×/week. Balance was evaluated by computerized posturography. Functionality was assessed by 10 m walk test, Timed up and Go (TUG) performance and endurance capacity (Shuttle Walk). Fall risk was determined with the Physiological Profile Assessment. Performance on the 10 m walk test and on TUG improved over time in all groups. For none of the parameters, high-dose vitamin D resulted in a better performance than conventional dosing. The improvements in the WBV group in endurance capacity, walking at preferred speed, and TUG were significantly larger than the changes with supplementation alone. No additional benefit of WBV training could be detected on fall risk and postural control, although sway velocity and maximal isometric knee extension strength improved only in the WBV group. This trial showed that a high-dose vitamin D supplementation is not more efficient than conventional dosing in improving functionality in institutionalized elderly. WBV training on top of vitamin D supplementation provided an added benefit with regard to walking, TUG performance, and endurance capacity. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Low-dose 5-fluorouracil in combination with salicylic acid for the treatment of actinic keratoses on the hands and/or forearms - results of a non-interventional study.

    PubMed

    Reinhold, U; Hadshiew, I; Melzer, A; Prechtl, A

    2017-03-01

    As an in situ carcinoma, actinic keratoses should be treated early. Previous studies on the efficacy of a low-dose 0.5% 5-fluorouracil solution in combination with 10% salicylic acid (low-dose 5-FU/SA) are mostly related to lesions appearing on the head and face. In contrast, actinic keratoses (AK) lesions of the upper extremities are considered to be difficult to treat. The efficacy of low-dose 5-FU/SA in the treatment of actinic keratoses on the hands and/or forearms was studied for the first time in this non-interventional study (NIS) under practical conditions in a large patient population. In addition to the clinical course during therapy and a follow-up period, the length of application and adherence were documented. As part of this NIS, 649 patients with AK were treated at 207 centres with low-dose 5-FU/SA. The data of the study were recorded at baseline, optionally during an intermediate examination, at the end of therapy and during a final assessment. The average number of AK lesions decreased during the entire observation period by 92%. Side-effects were documented only rarely in the form of local skin reactions (2%). The attending physicians assessed the efficacy, tolerability and safety of the therapy as being predominantly very good or good (in each case ≥90%). AK lesions on the hands and/or forearms were effectively treated with low-dose 5-FU/SA under routine conditions in dermatological practice and the treatment was well tolerated. © 2016 European Academy of Dermatology and Venereology.

  10. A phase IB study of ipilimumab with peginterferon alfa-2b in patients with unresectable melanoma.

    PubMed

    Brohl, Andrew S; Khushalani, Nikhil I; Eroglu, Zeynep; Markowitz, Joseph; Thapa, Ram; Chen, Y Ann; Kudchadkar, Ragini; Weber, Jeffrey S

    2016-01-01

    Ipilimumab and peginterferon alfa-2b are established systemic treatment options for melanoma that have distinct mechanisms of action. Given the need for improved therapies for advanced melanoma, we conducted an open-label, single institution, phase Ib study to assess the safety and tolerability of using these two agents in combination. Study treatment consisted of ipilimumab given every 3 weeks, for a total of four infusions, concurrent with peginterferon alfa-2b administered subcutaneous weekly for a total of 12 weeks. This was followed by maintenance therapy with peginterferon alfa-2b administered subcutaneously weekly for up to 144 additional weeks. The study was designed as a two-stage dose escalation scheme with continuous dose-limiting toxicity monitoring during the induction phase. Thirty one patients received at least 1 dose of study treatment and 30 were assessable for efficacy endpoints. We found that ipilimumab at 3 mg/kg dosing with peginterfeon alfa-2b at 2 μg/kg/week was the maximum tolerated dose of this combination. The incidence of grade 3 drug-related adverse events (AEs) was 45.2%. There were no grade 4/5 AEs. The overall response rate was 40% by immune-related response criteria. Median progression-free survival was 5.9 months. The median overall survival was not reached with at a median follow-up of 35.8 months. We report that the combination of ipilimumab at 3 mg/kg dosing combined with peginterfeon alfa-2b at 2 μg/kg/week demonstrated an acceptable toxicity profile and a promising efficacy signal. Further study of this combination is warranted. ClinicalTrials.gov identifier: NCT01496807, Registered December 19th, 2011.

  11. Bumetanide for the treatment of seizures in newborn babies with hypoxic ischaemic encephalopathy (NEMO): an open-label, dose finding, and feasibility phase 1/2 trial.

    PubMed

    Pressler, Ronit M; Boylan, Geraldine B; Marlow, Neil; Blennow, Mats; Chiron, Catherine; Cross, J Helen; de Vries, Linda S; Hallberg, Boubou; Hellström-Westas, Lena; Jullien, Vincent; Livingstone, Vicki; Mangum, Barry; Murphy, Brendan; Murray, Deirdre; Pons, Gerard; Rennie, Janet; Swarte, Renate; Toet, Mona C; Vanhatalo, Sampsa; Zohar, Sarah

    2015-05-01

    Preclinical data suggest that the loop-diuretic bumetanide might be an effective treatment for neonatal seizures. We aimed to assess dose and feasibility of intravenous bumetanide as an add-on to phenobarbital for treatment of neonatal seizures. In this open-label, dose finding, and feasibility phase 1/2 trial, we recruited full-term infants younger than 48 h who had hypoxic ischaemic encephalopathy and electrographic seizures not responding to a loading-dose of phenobarbital from eight neonatal intensive care units across Europe. Newborn babies were allocated to receive an additional dose of phenobarbital and one of four bumetanide dose levels by use of a bivariate Bayesian sequential dose-escalation design to assess safety and efficacy. We assessed adverse events, pharmacokinetics, and seizure burden during 48 h continuous electroencephalogram (EEG) monitoring. The primary efficacy endpoint was a reduction in electrographic seizure burden of more than 80% without the need for rescue antiepileptic drugs in more than 50% of infants. The trial is registered with ClinicalTrials.gov, number NCT01434225. Between Sept 1, 2011, and Sept 28, 2013, we screened 30 infants who had electrographic seizures due to hypoxic ischaemic encephalopathy. 14 of these infants (10 boys) were included in the study (dose allocation: 0·05 mg/kg, n=4; 0·1 mg/kg, n=3; 0·2 mg/kg, n=6; 0·3 mg/kg, n=1). All babies received at least one dose of bumetanide with the second dose of phenobarbital; three were withdrawn for reasons unrelated to bumetanide, and one because of dehydration. All but one infant also received aminoglycosides. Five infants met EEG criteria for seizure reduction (one on 0·05 mg/kg, one on 0·1 mg/kg and three on 0·2 mg/kg), and only two did not need rescue antiepileptic drugs (ie, met rescue criteria; one on 0·05 mg/kg and one on 0·3 mg/kg). We recorded no short-term dose-limiting toxic effects, but three of 11 surviving infants had hearing impairment confirmed on auditory testing between 17 and 108 days of age. The most common non-serious adverse reactions were moderate dehydration in one, mild hypotension in seven, and mild to moderate electrolyte disturbances in 12 infants. The trial was stopped early because of serious adverse reactions and limited evidence for seizure reduction. Our findings suggest that bumetanide as an add-on to phenobarbital does not improve seizure control in newborn infants who have hypoxic ischaemic encephalopathy and might increase the risk of hearing loss, highlighting the risks associated with the off-label use of drugs in newborn infants before safety assessment in controlled trials. European Community's Seventh Framework Programme. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis

    PubMed Central

    van Boven, Job FM; van Raaij, Joost J; van der Galiën, Ruben; Postma, Maarten J; van der Molen, Thys; Dekhuijzen, PN Richard; Vegter, Stefan

    2014-01-01

    Background: With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians in prescribing the optimal medication in relation to chronic obstructive pulmonary disease (COPD) patients’ persistence with long-acting β2-agonists (LABAs). Aims: To assess the impact of the type of inhaler device (multiple-dose versus single-dose inhalers) on 1-year persistence and switching patterns with LABAs. Methods: A retrospective observational cohort study was performed comparing a cohort of patients initiating multiple-dose inhalers and a cohort initiating single-dose inhalers. The study population consisted of long-acting bronchodilator naive COPD patients, initiating inhalation therapy with mono-LABAs (formoterol, indacaterol or salmeterol). Analyses were performed using pharmacy dispensing data from 1994 to 2012, obtained from the IADB.nl database. Study outcomes were 1-year persistence and switching patterns. Results were adjusted for initial prescriber, initial medication, dosing regimen and relevant comorbidities. Results: In all, 575 patients initiating LABAs were included in the final study cohort. Among them, 475 (83%) initiated a multiple-dose inhaler and 100 (17%) a single-dose inhaler. Further, 269 (47%) initiated formoterol, 9 (2%) indacaterol and 297 (52%) salmeterol. There was no significant difference in persistence between users of multiple-dose or single-dose inhalers (hazard ratio: 0.98, 95% confidence interval: 0.76–1.26, P=0.99). Over 80% re-started or switched medication. Conclusions: There seems no impact of inhaler device (multiple-dose versus single-dose inhalers) on COPD patients’ persistence with LABAs. Over 80% of patients who initially seemed to discontinue LABAs, re-started their initial medication or switched inhalers or medication within 1 year. PMID:25274453

  13. Efficacy and Safety of Fixed-Dose Perindopril Arginine/Amlodipine in Hypertensive Patients Not Adequately Controlled with Amlodipine 5 mg or Perindopril tert-Butylamine 4 mg Monotherapy.

    PubMed

    Hu, Dayi; Sun, Yihong; Liao, Yuhua; Huang, Jing; Zhao, Ruiping; Yang, Kan

    2016-01-01

    To assess the blood pressure-lowering efficacy and tolerability of perindopril/amlodipine fixed-dose combinations in Chinese patients with mild-to-moderate essential hypertension not adequately controlled with monotherapy alone. In 2 separate double-blind studies, patients received a 4-week run-in monotherapy of amlodipine 5 mg or perindopril 4 mg, respectively. Those whose blood pressure was uncontrolled were then randomized to receive the fixed-dose combination of perindopril 5 mg/amlodipine 5 mg (Per/Amlo group) or remain on the monotherapy for 8 weeks. Patients who were uncontrolled at the week 8 (W8) visit were up-titrated for the Per/Amlo combination, or received additional treatment if on monotherapy, for a further 4 weeks. The main efficacy assessment was at 8 weeks. After 8 weeks, systolic blood pressure (SBP; primary criterion) was statistically significantly lower in the Per/Amlo group (vs. Amlo 5 mg, p = 0.0095; vs. Per 4 mg, p < 0.0001). Uncontrolled patients at W8 who received an up-titration of the Per/Amlo combination showed a further SBP reduction. These changes were mirrored by reassuring reductions in diastolic blood pressure. The fixed-dose combinations were well tolerated. Single-pill combinations of perindopril and amlodipine provide hypertensive patients with a convenient and effective method of reducing blood pressure. © 2016 S. Karger AG, Basel.

  14. An assessment of absorbed dose and radiation hazard index from soil around repository facility at Bukit Kledang, Perak, Malaysia

    NASA Astrophysics Data System (ADS)

    Adziz, M. I. Abdul; Khoo, K. S.

    2018-01-01

    The process of natural decay of radionuclides that emit gamma rays can infect humans and other living things. In this study, soil samples were taken at various locations which have been identified around the Long Term Storage Facility (LTSF) in Bukit Kledang, Perak. In addition, the respective dose rates in the sampling sites were measured at 5cm and 1m above the ground using a survey meter with Geiger Muller (GM) detector. Soil samples were taken using a hand Auger and then brought back to the laboratory for sample prepreparation process. The measuring of radioactivity concentration in soil samples were carried out using gamma spectrometer counting system equipped with HPGe detector. The obtained results show, the radioactivity concentration ranged from 11.98 - 29.93 Bq/kg for Radium-226 (226Ra), 20.97 - 41.45 Bq/kg for Thorium-232 (232Th) and 5.73 - 59.41 Bq/kg for Potassium-40 (40K), with mean values of 20.83 ± 5.88 Bq/kg, 32.87 ± 5.88 Bq/kg and 21.50 ± 2.79 Bq/kg, respectively. To assess the radiological hazards of natural radioactivity, radium equivalent activity (Raeq), the rate of absorption dose (D), the annual effective dose and external hazard index (Hex) was calculated and compared to the world average values.

  15. Assessing doses to terrestrial wildlife at a radioactive waste disposal site: inter-comparison of modelling approaches.

    PubMed

    Johansen, M P; Barnett, C L; Beresford, N A; Brown, J E; Černe, M; Howard, B J; Kamboj, S; Keum, D-K; Smodiš, B; Twining, J R; Vandenhove, H; Vives i Batlle, J; Wood, M D; Yu, C

    2012-06-15

    Radiological doses to terrestrial wildlife were examined in this model inter-comparison study that emphasised factors causing variability in dose estimation. The study participants used varying modelling approaches and information sources to estimate dose rates and tissue concentrations for a range of biota types exposed to soil contamination at a shallow radionuclide waste burial site in Australia. Results indicated that the dominant factor causing variation in dose rate estimates (up to three orders of magnitude on mean total dose rates) was the soil-to-organism transfer of radionuclides that included variation in transfer parameter values as well as transfer calculation methods. Additional variation was associated with other modelling factors including: how participants conceptualised and modelled the exposure configurations (two orders of magnitude); which progeny to include with the parent radionuclide (typically less than one order of magnitude); and dose calculation parameters, including radiation weighting factors and dose conversion coefficients (typically less than one order of magnitude). Probabilistic approaches to model parameterisation were used to encompass and describe variable model parameters and outcomes. The study confirms the need for continued evaluation of the underlying mechanisms governing soil-to-organism transfer of radionuclides to improve estimation of dose rates to terrestrial wildlife. The exposure pathways and configurations available in most current codes are limited when considering instances where organisms access subsurface contamination through rooting, burrowing, or using different localised waste areas as part of their habitual routines. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  16. Irradiation doses on thyroid gland during the postoperative irradiation for breast cancer.

    PubMed

    Akın, Mustafa; Ergen, Arzu; Unal, Aysegul; Bese, Nuran

    2014-01-01

    Thyroid gland is one of the radiosensitive endocrine organs in the body. It has been shown that direct irradiation of thyroid with total doses of 26 to 30 Gy can lead to functional abnormalities. In this study, irradiation doses on thyroid gland of the patients who received postoperative chest-wall/breast and regional nodal irradiation were assessed. Retrospective analyses of treatment plans from 122 breast cancer patients who were treated with 3D conformal radiotherapy (3D CRT) planning was performed. All patients received irradiation to supraclavicular/level III lymph nodes in addition to chest-wall/breast. A total dose of 46 Gy was delivered in 25 days to supraclavicular/level III lymph node region while a total dose of 50 Gy was delivered to whole breast/chest-wall. Thyroid gland was contoured on 2-5 mm thickness of computed tomography scans. Absolute thyroid volume, mean thyroid doses were calculated. The mean thyroid volume of all patients was 16.7 cc (min: 1.9 cc, max: 41.6 cc). The mean irradiation dose on was 22.5 Gy (0.32 Gy-46.5 Gy). The level of dose was higher than 26 Gy in 44% of the patients. In majority of the node-positive breast cancer patients treated with 3D CRT, the thyroid gland was exposed to considerable doses. On the other hand, for 44% of the patients are at risk for developing thyroid function abnormalities which should be considered during the routine follow-up.

  17. Introduction to benchmark dose methods and U.S. EPA's benchmark dose software (BMDS) version 2.1.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, J. Allen, E-mail: davis.allen@epa.gov; Gift, Jeffrey S.; Zhao, Q. Jay

    2011-07-15

    Traditionally, the No-Observed-Adverse-Effect-Level (NOAEL) approach has been used to determine the point of departure (POD) from animal toxicology data for use in human health risk assessments. However, this approach is subject to substantial limitations that have been well defined, such as strict dependence on the dose selection, dose spacing, and sample size of the study from which the critical effect has been identified. Also, the NOAEL approach fails to take into consideration the shape of the dose-response curve and other related information. The benchmark dose (BMD) method, originally proposed as an alternative to the NOAEL methodology in the 1980s, addressesmore » many of the limitations of the NOAEL method. It is less dependent on dose selection and spacing, and it takes into account the shape of the dose-response curve. In addition, the estimation of a BMD 95% lower bound confidence limit (BMDL) results in a POD that appropriately accounts for study quality (i.e., sample size). With the recent advent of user-friendly BMD software programs, including the U.S. Environmental Protection Agency's (U.S. EPA) Benchmark Dose Software (BMDS), BMD has become the method of choice for many health organizations world-wide. This paper discusses the BMD methods and corresponding software (i.e., BMDS version 2.1.1) that have been developed by the U.S. EPA, and includes a comparison with recently released European Food Safety Authority (EFSA) BMD guidance.« less

  18. Persistence of antibodies in adolescents 18−24 months after immunization with one, two, or three doses of 4CMenB meningococcal serogroup B vaccine

    PubMed Central

    Santolaya, Maria Elena; O'Ryan, Miguel; Valenzuela, María Teresa; Prado, Valeria; Vergara, Rodrigo F; Muñoz, Alma; Toneatto, Daniela; Graña, Gabriela; Wang, Huajun; Dull, Peter M

    2013-01-01

    We previously demonstrated the immunogenicity and tolerability of the serogroup B meningococcal vaccine, 4CMenB (Bexsero®), in 11−17 y-olds randomized to receive 1, 2, or 3 doses at 1, 2, or 6 mo intervals. Participants in this extension study provided an additional blood sample 18−24 mo after last vaccine dose, to assess persistence of serum bactericidal activity with human complement (hSBA), and to compare with age-matched 4CMenB-naïve controls. In the original study, one month after one 4CMenB dose, 93% of subjects had seroprotective hSBA titers (≥4) against indicator serogroup B strains for individual vaccine antigens (fHbp, NadA and NZOMV), increasing to ~100% after two or three doses. After 18−24 mo, 62−73% of subjects given one dose had titers ≥4 against the three antigens, significantly lower rates than after two (77−94%) or three (86−97%) doses. Only proportions with titers ≥ 4 against NZOMV were significantly different between the two (77%) and three (90%, p < 0.0001) dose groups. These results confirm that two doses of 4CMenB, administered 1 to 6 mo apart, provide good levels of bactericidal activity against serogroup B meningococci, which were sustained at least 18−24 mo in over 64% of adolescents for all three tested vaccine-related antigens. PMID:23811804

  19. Secondary neutron dose measurement for proton eye treatment using an eye snout with a borated neutron absorber

    PubMed Central

    2013-01-01

    Background We measured and assessed ways to reduce the secondary neutron dose from a system for proton eye treatment. Methods Proton beams of 60.30 MeV were delivered through an eye-treatment snout in passive scattering mode. Allyl diglycol carbonate (CR-39) etch detectors were used to measure the neutron dose in the external field at 0.00, 1.64, and 6.00 cm depths in a water phantom. Secondary neutron doses were measured and compared between those with and without a high-hydrogen–boron-containing block. In addition, the neutron energy and vertices distribution were obtained by using a Geant4 Monte Carlo simulation. Results The ratio of the maximum neutron dose equivalent to the proton absorbed dose (H(10)/D) at 2.00 cm from the beam field edge was 8.79 ± 1.28 mSv/Gy. The ratio of the neutron dose equivalent to the proton absorbed dose with and without a high hydrogen-boron containing block was 0.63 ± 0.06 to 1.15 ± 0.13 mSv/Gy at 2.00 cm from the edge of the field at depths of 0.00, 1.64, and 6.00 cm. Conclusions We found that the out-of-field secondary neutron dose in proton eye treatment with an eye snout is relatively small, and it can be further reduced by installing a borated neutron absorbing material. PMID:23866307

  20. Effects of supplementation with higher levels of manganese and magnesium on immune function.

    PubMed

    Son, Eun-Wha; Lee, Sung-Ryul; Choi, Hye-Sook; Koo, Hyun-Jung; Huh, Jung-Eun; Kim, Mi-Hyun; Pyo, Suhkneung

    2007-06-01

    The magnesium (Mg) and manganese (Mn) were evaluated for its effectiveness as an immunomodulator in rats. The treatments were as follows: Group 1, AIN-93M diet (0.05% Mg, 0.001% Mn); Group 2, high-dose Mg (0.1% Mg, 0.001% Mn); and Group 3, high dose Mn (0.05% Mg, 0.01% Mn) (n-12/group). After 12 weeks of supplementation, rats were sacrificed to assess the effect on a range of innate responses (tumoricidal activity, oxidative burst and nitric oxide) and the mitogen-stimulated lymphoproliferative response. Immune function was significantly affected in both the high dose Mg and the Mn group. Lymphocyte proliferative responses and NK cell activity were measured in pooled spleen from each group. The mitogen response of lymphocytes to LPS in the spleen was significantly reduced in high dose Mg-treated groups, whereas the response to ConA was not affected in both high dose minerals-treated groups. The reactive oxygen species level of macrophages was decreased in both groups. These effects were more pronounced in high dose Mg-treated group. Nitric oxide production was also decreased in high dose minerals-treated group. In addition, tumoricidal activities of splenic NK cell and peritoneal macrophage in mineral exposed rats were significantly increased. Moreover, percent death of macrophage was reduced in two groups receiving high dose mineral supplements. Taken together, the present data suggest that high dose trace min erals exert a differential effect on the function of immune cells.

  1. ICRP Publication 137: Occupational Intakes of Radionuclides: Part 3.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Marsh, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Blanchardon, E; Gregoratto, D; Harrison, J D

    2017-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988) and Publication 68 (ICRP, 1994). In addition, new data are now available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. OIR Part 1 has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. OIR Part 2 (ICRP, 2016), this current publication and upcoming publications in the OIR series (Parts 4 and 5) provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv Bq−1 intake) for inhalation and ingestion, tables of committed effective dose per content (Sv Bq−1 measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of publications contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. This third publication in the series provides the above data for the following elements: ruthenium (Ru), antimony (Sb), tellurium (Te), iodine (I), caesium (Cs), barium (Ba), iridium (Ir), lead (Pb), bismuth (Bi), polonium (Po), radon (Rn), radium (Ra), thorium (Th), and uranium (U).

  2. ICRP Publication 134: Occupational Intakes of Radionuclides: Part 2.

    PubMed

    Paquet, F; Bailey, M R; Leggett, R W; Lipsztein, J; Fell, T P; Smith, T; Nosske, D; Eckerman, K F; Berkovski, V; Ansoborlo, E; Giussani, A; Bolch, W E; Harrison, J D

    2016-12-01

    The 2007 Recommendations of the International Commission on Radiological Protection (ICRP, 2007) introduced changes that affect the calculation of effective dose, and implied a revision of the dose coefficients for internal exposure, published previously in the Publication 30 series (ICRP, 1979, 1980, 1981, 1988b) and Publication 68 (ICRP, 1994b). In addition, new data are available that support an update of the radionuclide-specific information given in Publications 54 and 78 (ICRP, 1988a, 1997b) for the design of monitoring programmes and retrospective assessment of occupational internal doses. Provision of new biokinetic models, dose coefficients, monitoring methods, and bioassay data was performed by Committee 2, Task Group 21 on Internal Dosimetry, and Task Group 4 on Dose Calculations. A new series, the Occupational Intakes of Radionuclides (OIR) series, will replace the Publication 30 series and Publications 54, 68, and 78. Part 1 of the OIR series has been issued (ICRP, 2015), and describes the assessment of internal occupational exposure to radionuclides, biokinetic and dosimetric models, methods of individual and workplace monitoring, and general aspects of retrospective dose assessment. The following publications in the OIR series (Parts 2–5) will provide data on individual elements and their radioisotopes, including information on chemical forms encountered in the workplace; a list of principal radioisotopes and their physical half-lives and decay modes; the parameter values of the reference biokinetic model; and data on monitoring techniques for the radioisotopes encountered most commonly in workplaces. Reviews of data on inhalation, ingestion, and systemic biokinetics are also provided for most of the elements. Dosimetric data provided in the printed publications of the OIR series include tables of committed effective dose per intake (Sv per Bq intake) for inhalation and ingestion, tables of committed effective dose per content (Sv per Bq measurement) for inhalation, and graphs of retention and excretion data per Bq intake for inhalation. These data are provided for all absorption types and for the most common isotope(s) of each element. The electronic annex that accompanies the OIR series of reports contains a comprehensive set of committed effective and equivalent dose coefficients, committed effective dose per content functions, and reference bioassay functions. Data are provided for inhalation, ingestion, and direct input to blood. The present publication provides the above data for the following elements: hydrogen (H), carbon (C), phosphorus (P), sulphur (S), calcium (Ca), iron (Fe), cobalt (Co), zinc (Zn), strontium (Sr), yttrium (Y), zirconium (Zr), niobium (Nb), molybdenum (Mo), and technetium (Tc).

  3. Radiological NESHAP ANNUAL REPORT CY 2016.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evelo, Stacie

    2017-06-01

    This report provides a summary of the radionuclide releases from the United States (U.S.) Department of Energy (DOE) National Nuclear Security Administration facilities at Sandia National Laboratories, New Mexico (SNL/NM) during Calendar Year (CY) 2016, including the data, calculations, and supporting documentation for demonstrating compliance with 40 Code of Federal Regulation (CFR) 61, Subpart H--NATIONAL EMISSION STANDARDS FOR EMISSIONS OF RADIONUCLIDES OTHER THAN RADON FROM DEPARTMENT OF ENERGY FACILITIES (Radiological NESHAP). A description is given of the sources and their contributions to the overall dose assessment. In addition, the maximally exposed individual (MEI) radiological dose calculation and the population dosemore » to local and regional residents are discussed.« less

  4. STABILITY OF THE NEUTRON DOSE DETERMINATION ALGORITHM FOR PERSONAL NEUTRON DOSEMETERS AT DIFFERENT RADON GAS EXPOSURES.

    PubMed

    Mayer, Sabine; Boschung, Markus; Butterweck, Gernot; Assenmacher, Frank; Hohmann, Eike

    2016-09-01

    Since 2008 the Paul Scherrer Institute (PSI) has been using a microscope-based automatic scanning system for assessing personal neutron doses with a dosemeter based on PADC. This scanning system, known as TASLImage, includes a comprehensive characterisation of tracks. The distributions of several specific track characteristics such as size, shape and optical density are compared with a reference set to discriminate tracks of alpha particles and non-track background. Due to the dosemeter design at PSI, it is anticipated that radon should not significantly contribute to the creation of additional tracks in the PADC detector. The present study tests the stability of the neutron dose determination algorithm of the personal neutron dosemeter system in operation at PSI at different radon gas exposures. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ke, Ruian; Loverdo, Claude; Qi, Hangfei

    Recent discoveries of direct acting antivirals against Hepatitis C virus (HCV) have raised hopes of effective treatment via combination therapies. Yet rapid evolution and high diversity of HCV populations, combined with the reality of suboptimal treatment adherence, make drug resistance a clinical and public health concern. We develop a general model incorporating viral dynamics and pharmacokinetics/ pharmacodynamics to assess how suboptimal adherence affects resistance development and clinical outcomes. We derive design principles and adaptive treatment strategies, identifying a high-risk period when missing doses is particularly risky for de novo resistance, and quantifying the number of additional doses needed to compensatemore » when doses are missed. Using data from large-scale resistance assays, we demonstrate that the risk of resistance can be reduced substantially by applying these principles to a combination therapy of daclatasvir and asunaprevir. By providing a mechanistic framework to link patient characteristics to the risk of resistance, these findings show the potential of rational treatment design.« less

  6. A phase I study of human natural interferon-beta in cancer patients.

    PubMed

    Liberati, A M; Biscottini, B; Fizzotti, M; Schippa, M; De Angelis, V; Senatore, M; Vittori, O; Teggia, L; Natali, R; Palmisano, L

    1989-06-01

    In this phase I study 15 patients with metastatic tumors were given interferon (IFN)-beta by i.v. bolus injections. Twelve individual doses of 1, 2, 3.3, 5, 7, 9, 12, 16, 21, 27, 35, and 46 x 10(6) IU were administered every other day. The single maximal tolerated dose ranged from 9 to 46 x 10(6) IU. Eight patients tolerated the dose of 46 x 10(6) IU without side effects. Disturbances of cardiac rhythm were observed, but were closely related temporally to severe chills and appeared to be the consequence of adrenergic stimulation associated with this side-effect. In addition, no significant variations in the left ventricular function as assessed by nuclear stethoscope were observed. Neurotoxicity was not a major side-effect. The toxicity of IFN-beta given as scheduled in this study was significant, but acceptable.

  7. Differentially expressed genes and pathways induced by organophosphates in human neuroblastoma cells.

    PubMed

    Li, Tianwei; Zhao, Hongtao; Hung, Guo-Chiuan; Han, Jing; Tsai, Shien; Li, Bingjie; Zhang, Jing; Puri, Raj K; Lo, Shyh-Ching

    2012-12-01

    Organophosphates (OPs) are toxic chemicals commonly used as pesticides and herbicides. Some OPs are highly toxic to humans and have been used in warfare and terrorist attacks. In order to elucidate the molecular mechanisms of injury caused by OPs, the differentially expressed genes were analyzed in human SK-N-SH neuroblastoma cells induced by three OPs. The SK-N-SH cells were treated with one of the three OPs, chlorpyrifos, dichlorvos or methamidophos at LC20 (high-dose), the concentration causing 20% cell death, as well as 1/20 of LC20 (low-dose), a sub-lethal concentration with no detectable cell death, for 24 h. The genome-wide gene changes were identified by Agilent Microarray System, and analyzed by microarray analysis tools. The analysis revealed neuroblastoma cells treated with the high doses of all three OPs markedly activated cell apoptosis and inhibited cell growth and proliferation genes, which would most likely lead to the process of cell death. Interestingly, the analysis also revealed significant decrease in expressions of many genes in a specific spliceosome pathway in cells treated with the low doses of all three different OPs. The change of spliceosome pathway may represent an important mechanism of injury in neuronal cells exposed to low doses of various OPs. In addition to unraveling a potentially different form of OP pathogenesis, this finding could provide a new diagnostic marker in assessing OP-associated injury in cells or tissues. In addition, these results could also contribute to the development of new prevention and/or therapeutic regimens against OP toxicity.

  8. Memory and mood during the night and in the morning after repeated evening doses of MDMA.

    PubMed

    Kuypers, K P C; Wingen, M; Ramaekers, J G

    2008-11-01

    Previously it has been shown that MDMA causes memory impairment during daytime testing. However, MDMA is usually taken in the evening or during the night. In addition, it is known that sleep deprivation also causes memory impairment. The present study aimed to assess whether evening doses of MDMA added to, or interacted with the memory impairment due to sleep deprivation. Fourteen healthy subjects participated in a double-blind, placebo-controlled, two-way cross-over study. Treatments consisted of MDMA 75 and 50 mg divided over the evening or double placebo. Memory tests and subjective measures of mood were conducted at baseline and three times post dosing that is at 6.30 pm, 9.30 pm, 1.30 am and 7 am, respectively -1.5, 1.5, 5.5 and 11 h relative to drug intake (first dose). Memory performance detoriated progessively over time as a function of sleep loss, independent of treatment. MDMA added to this impairment as indicated by a significant main effect of MDMA on verbal and spatial memory performance. Mood ratings and response speed revealed an MDMA by Time interaction. After administration of MDMA response speed improved and feelings of vigor, friendliness, elation, anxiety, confusion, arousal and positive mood increased in magnitude during the night, while all these parameters returned to placebo-like levels on the final morning session. It is concluded that evening doses of MDMA selectively impair memory performance, and that this impairment is additional to the effect of sleep deprivation on memory performance.

  9. Microbial Risk Assessment

    NASA Technical Reports Server (NTRS)

    Ott, C. M.; Mena, K. D.; Nickerson, C.A.; Pierson, D. L.

    2009-01-01

    Historically, microbiological spaceflight requirements have been established in a subjective manner based upon expert opinion of both environmental and clinical monitoring results and the incidence of disease. The limited amount of data, especially from long-duration missions, has created very conservative requirements based primarily on the concentration of microorganisms. Periodic reevaluations of new data from later missions have allowed some relaxation of these stringent requirements. However, the requirements remain very conservative and subjective in nature, and the risk of crew illness due to infectious microorganisms is not well defined. The use of modeling techniques for microbial risk has been applied in the food and potable water industries and has exceptional potential for spaceflight applications. From a productivity standpoint, this type of modeling can (1) decrease unnecessary costs and resource usage and (2) prevent inadequate or inappropriate data for health assessment. In addition, a quantitative model has several advantages for risk management and communication. By identifying the variable components of the model and the knowledge associated with each component, this type of modeling can: (1) Systematically identify and close knowledge gaps, (2) Systematically identify acceptable and unacceptable risks, (3) Improve communication with stakeholders as to the reasons for resource use, and (4) Facilitate external scientific approval of the NASA requirements. The modeling of microbial risk involves the evaluation of several key factors including hazard identification, crew exposure assessment, dose-response assessment, and risk characterization. Many of these factors are similar to conditions found on Earth; however, the spaceflight environment is very specialized as the inhabitants live in a small, semi-closed environment that is often dependent on regenerative life support systems. To further complicate modeling efforts, microbial dose-response characteristics may be affected by a potentially dysfunctional crew immune system during a mission. In addition, microbial virulence has been shown to change under certain conditions during spaceflight, further complicating dose-response characterization. An initial study of the applicability of microbial risk assessment techniques was performed using Crew Health Care System (CHeCS) operational data from the International Space Station potable water systems. The risk of infection from potable water was selected as the flight systems and microbial ecology are well defined. This initial study confirmed the feasibility of using microbial risk assessment modeling for spaceflight systems. While no immediate threat was detected, the study identified several medically significant microorganisms that could pose a health risk if uncontrolled. The study also identified several specific knowledge gaps in making a risk assessment and noted that filling these knowledge gaps is essential as the risk estimates may change by orders of magnitude depending on the answers. The current phase of the microbial risk assessment studies focuses on the dose-response relationship of specific infectious agents, focusing on Salmonella enterica Typhimurium, Pseudomonas spp., and Escherichia coli, as their evaluation will provide a better baseline for determining the overall hazard characterization. The organisms were chosen as they either have been isolated on spacecraft or have an identified route of infection during a mission. The characterization will utilize dose-response models selected either from the peer-reviewed literature and/or by using statistical approaches. Development of these modeling and risk assessment techniques will help to optimize flight requirements and to protect the safety, health, and performance of the crew.

  10. Assessment of the genotoxic/clastogenic potential of coumarin derivative 6,7-dihydroxycoumarin (aesculetin) in multiple mouse organs.

    PubMed

    Marques, Eduardo de Souza; Salles, Daiane Bernardoni; Maistro, Edson Luis

    2015-01-01

    6,7-Dihydroxycoumarin (6,7-HC) (aesculetin) is a natural and synthetic coumarin derivative of great interest for use by humans due to their potent antioxidant properties. Considering that there are no reports that assess the in vivo genetic toxicity of 6,7-HC, the aim of the present study was to investigate its genotoxic potential in terms of DNA damage in peripheral blood, liver, bone marrow and testicular cells of Swiss albino mice by the comet assay, and its clastogenic/aneugenic potential in bone marrow cells using the micronucleus test. In addition, the ability of 6,7-HC to modulate the genotoxic effects induced by doxorubicin (DXR) was also preliminarily evaluated. Cytotoxicity was assessed by scoring polychromatic (PCE) and normochromatic (NCE) erythrocytes' ratio. The test compound was administered orally at doses of 25, 50 and 500 mg kg -1 isolated and also simultaneously to DXR (80 mg kg -1 ). The results showed that 6,7-HC did not induce significant DNA damage in any of the analyzed cells, and also did not show any significant increase in micronucleated PCE at the three tested doses. The PCE/NCE ratio indicated no cytotoxicity. Moreover, the extent of DNA damage induced by DXR decreased significantly only in peripheral blood and testicular cells, and only at the lowest dose of 6,7-HC.

  11. Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms

    NASA Astrophysics Data System (ADS)

    Zacharatou Jarlskog, Christina; Lee, Choonik; Bolch, Wesley E.; Xu, X. George; Paganetti, Harald

    2008-02-01

    Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the target requires whole-body geometrical information. Furthermore, because the patient geometry depends on age at exposure, age-dependent representations are also needed. We implemented age-dependent phantoms into our proton Monte Carlo dose calculation environment. We considered eight typical radiation fields, two of which had been previously used to treat pediatric patients. The other six fields were additionally considered to allow a systematic study of equivalent doses as a function of field parameters. For all phantoms and all fields, we simulated organ-specific equivalent neutron doses and analyzed for each organ (1) the equivalent dose due to neutrons as a function of distance to the target; (2) the equivalent dose due to neutrons as a function of patient age; (3) the equivalent dose due to neutrons as a function of field parameters; and (4) the ratio of contributions to secondary dose from the treatment head versus the contribution from the patient's body tissues. This work reports organ-specific equivalent neutron doses for up to 48 organs in a patient. We demonstrate quantitatively how organ equivalent doses for adult and pediatric patients vary as a function of patient's age, organ and field parameters. Neutron doses increase with increasing range and modulation width but decrease with field size (as defined by the aperture). We analyzed the ratio of neutron dose contributions from the patient and from the treatment head, and found that neutron-equivalent doses fall off rapidly as a function of distance from the target, in agreement with experimental data. It appears that for the fields used in this study, the neutron dose lateral to the field is smaller than the reported scattered photon doses in a typical intensity-modulated photon treatment. Most importantly, our study shows that neutron doses to specific organs depend considerably on the patient's age and body stature. The younger the patient, the higher the dose deposited due to neutrons. Given the fact that the risk also increases with decreasing patient age, this factor needs to be taken into account when treating pediatric patients of very young ages and/or of small body size. The neutron dose from a course of proton therapy treatment (assuming 70 Gy in 30 fractions) could potentially (depending on patient's age, organ, treatment site and area of CT scan) be equivalent to up to ~30 CT scans.

  12. New findings of oxidative stress biomarkers in nutritional research.

    PubMed

    Kochlik, Bastian; Grune, Tilman; Weber, Daniela

    2017-09-01

    The aim of this article is to present a brief overview of recently published articles assessing oxidative stress markers in nutritional studies. Intervention and observational studies were carried out in both, healthy subjects and patients and describe the association of foodstuffs as well as isolated nutrients with biomarkers of oxidative stress. The results from human intervention studies on healthy participants and patients are controversial. Long-term interventions (>8 weeks) seem to be more effective than short-term or single-dose interventions. Results are difficult to compare because not only the methods used, also the assessed biomarkers and outcomes were very diverse. In addition, studies vary in the compounds and doses used, duration, participants and so on. Different biomarkers (damaged molecules together with antioxidants from different compartments) should be assessed to evaluate the true 'redox-status' of an individual and the impact of a nutritional intervention. Both observational and interventional studies performed in healthy participants and patients show possible beneficial effects of nutrients and foodstuffs by improving oxidative stress markers and antioxidant enzyme activities. Biomarkers should be standardized to allow better comparison of results of antioxidant intervention studies.

  13. Safety assessment of the Cistanche tubulosa health food product Memoregain®: Genotoxicity and 28-day repeated dose toxicity test.

    PubMed

    Liao, Po-Lin; Li, Ching-Hao; Tse, Ling-Shan; Kang, Jaw-Jou; Cheng, Yu-Wen

    2018-06-07

    The pharmacological effects of Cistanches Herba, known as "Ginseng of the desert", have been extensively studied. In this study, we aimed to assess the genotoxic and oral toxic effects of the Cistanche tubulosa health food product Memoregain ® using in vitro and in vivo tests. Ames tests using five strains of Salmonella typhimurium showed no signs of increased reverse mutation upon exposure to Memoregain ® up to a concentration of 5 mg/plate. Exposure of Chinese hamster ovary (CHO-K1) cells to Memoregain ® did not increase the frequency of chromosomal aberrations in vitro. Moreover, Memoregain ® treatment did not affect the proportions of immature to total erythrocytes or the number of micronuclei in the immature erythrocytes of ICR mice. Additionally, after 28-day repeated oral dose toxicity tests (0, 0.15, 0.3, and 0.5g/kg body weight) in rats, no observable adverse effects were found. These toxicological assessments supported the safety of Memoregain ® for human consumption. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Approaches for the Application of Physiologically Based ...

    EPA Pesticide Factsheets

    This draft report of Approaches for the Application of Physiologically Based Pharmacokinetic (PBPK) Models and Supporting Data in Risk Assessment addresses the application and evaluation of PBPK models for risk assessment purposes. These models represent an important class of dosimetry models that are useful for predicting internal dose at target organs for risk assessment applications. Topics covered include:the types of data required use of PBPK models in risk assessment,evaluation of PBPK models for use in risk assessment, andthe application of these models to address uncertainties resulting from extrapolations (e.g. interspecies extrapolation) often used in risk assessment.In addition, appendices are provided that includea compilation of chemical partition coefficients and rate constants,algorithms for estimating chemical-specific parameters, anda list of publications relating to PBPK modeling. This report is primarily meant to serve as a learning tool for EPA scientists and risk assessors who may be less familiar with the field. In addition, this report can be informative to PBPK modelers within and outside the Agency, as it provides an assessment of the types of data and models that the EPA requires for consideration of a model for use in risk assessment.

  15. Development of an enzyme-linked immunosorbent assay for the serological detection of exposure of poultry in New Zealand to Erysipelothrix rhusiopathiae and their serological response to vaccination.

    PubMed

    Kurian, A; Neumann, E J; Hall, W F; Christensen, N

    2012-03-01

    To modify and validate an existing swine erysipelas ELISA for use with poultry serum and to assess the safety of a swine erysipelas vaccine for use in New Zealand layer birds. An existing swine erysipelas ELISA was modified for use in domestic poultry and was validated using sera from birds injected with either 2 mL of a commercially available killed swine erysipelas vaccine (low-dose; n=12 birds), 4 mL of vaccine (high-dose; n=11 birds), or 2 mL saline (control; n=11 birds) on Day 0 and again on Day 21. Blood samples were collected on Days 0, 21, 42, and 63, and safety of the vaccine for use in layer birds was determined by assessing cloacal temperature and injection site reactions in birds at 0, 4, 24, 48, 72 and 96 h post-vaccination. The ELISA that was developed had a diagnostic sensitivity and specificity of 93% and 98%, respectively, after being optimised for a positive cut-off at an optical density (OD) ≥ 1.50 read at 450-nm wavelength. OD readings were higher on Days 21, 42, and 63 than Day 0 in both the low-dose and high-dose groups (p<0.05), and differed amongst the three groups on Days 21, 42, and 63 (p<0.05), suggesting that vaccination using either dose induced detectable levels of antibody, even after a single dose. In addition, the high-dose protocol induced higher levels of antibody production than the low-dose protocol. No local or systemic reactions to the vaccine were observed and cloacal temperatures remained in the normal biological range after vaccination. The ELISA that was developed had satisfactory diagnostic performance characteristics and the vaccine appeared to be safe for use in layer birds. However, the study design did not permit an assessment of the vaccine's efficacy to protect birds from clinical erysipelas. A diagnostic ELISA has been developed for determining the exposure of layer birds to E. rhusiopathiae. The test will be useful for monitoring flock-level erysipelas, response to vaccination, and in epidemiological studies designed to identify risk factors for exposure to the disease.

  16. Piracetam relieves symptoms in progressive myoclonus epilepsy: a multicentre, randomised, double blind, crossover study comparing the efficacy and safety of three dosages of oral piracetam with placebo

    PubMed Central

    Koskiniemi, M.; Van Vleymen, B.; Hakamies, L.; Lamusuo, S.; Taalas, J.

    1998-01-01

    OBJECTIVE—To compare the efficacy, tolerability, and safety of three daily dosage regimens of oral piracetam in patients with progressive myoclonus epilepsy.
METHODS—Twenty patients (12 men, eight women), aged 17-43 years, with classical Unverricht-Lundborg disease were enrolled in a multicentre, randomised, double blind trial of crossover design in which the effects of daily doses of 9.6 g, 16.8 g, and 24 g piracetam, given in two divided doses, were compared with placebo. The crossover design was such that patients received placebo and two of the three dosage regimens of piracetam, each for two weeks, for a total treatment period of six weeks and thus without wash out between each treatment phase. The primary outcome measure was a sum score representing the adjusted total of the ratings of six components of a myoclonus rating scale in which stimulus sensitivity, motor impairment, functional disability, handwriting, and global assessments by investigators and patients were scored. Sequential clinical assessments were made by the same neurologist in the same environment at the same time of day.
RESULTS—Treatment with 24 g/day piracetam produced significant and clinically relevant improvement in the primary outcome measure of mean sum score (p=0.005) and in the means of its subtests of motor impairment (p=0.02), functional disability (p=0.003), and in global assessments by both investigator (p=0.002) and patient (p=0.01). Significant improvement in functional disability was also found with daily doses of 9.6 g and 16.8 g. The dose-effect relation was linear and significant. More patients showed clinically relevant improvement with the highest dosage and, in individual patients, increasing the dose improved response. Piracetam was well tolerated and adverse effects were few, mild, and transient.
CONCLUSIONS—This study provides further evidence that piracetam is an effective and safe medication in patients with Unverricht-Lundborg disease. In addition, it shows that a dose of 24 g is highly beneficial, more effective than lower doses and that a dose-effect relation exists. There is considerable variation in optimal individual dosage.

 PMID:9527146

  17. Pharmacological interaction between oxcarbazepine and two COX inhibitors in a rat model of inflammatory hyperalgesia.

    PubMed

    Stepanović-Petrović, Radica M; Tomić, Maja A; Vučković, Sonja M; Poznanović, Goran; Ugrešić, Nenad D; Prostran, Milica Š; Bošković, Bogdan

    2011-01-01

    Oxcarbazepine, ibuprofen and etodolac have efficacy in inflammatory pain. The combination of different drugs activates both central and peripheral pain inhibitory pathways to induce additive or synergistic antinociception, and this interaction may allow lower doses of each drug combined and improve the safety profile, with lower side-effects. This study aimed to examine the effects of oxcarbazepine-ibuprofen and oxcarbazepine-etodolac combinations, in a rat model of inflammatory hyperalgesia, and determine the type of interaction between drugs. Rats were intraplantarly injected with carrageenan (0.1 ml, 1%) and the hyperalgesia was assessed by modified paw pressure test. The anti-hyperalgesic effects of oxcarbazepine, ibuprofen and etodolac and oxcarbazepine-ibuprofen and oxcarbazepine-etodolac combinations were examined. Drugs were co-administered in a fixed-dose fractions of the ED₅₀ and the type of interaction was determined by isobolographic analysis. Oxcarbazepine (40-160 mg/kg; p.o.), ibuprofen (10-120 mg/kg; p.o.) and etodolac (5-20 mg/kg; p.o.) produced a significant, dose-dependent anti-hyperalgesia in carrageenan-injected rats. ED₅₀ values (mean±SEM) for oxcarbazepine, ibuprofen and etodolac were 88.17±3.65, 47.07±10.27 and 13.05±1.42 mg/kg, respectively. Oxcarbazepine-ibuprofen and oxcarbazepine-etodolac combinations induced significant and dose-dependent anti-hyperalgesia. Isobolographic analysis revealed that oxcarbazepine exerts a synergistic interaction with ibuprofen, with almost 4-fold reduction of doses of both drugs in combination. In contrast, there was an additive interaction with etodolac. Synergistic interaction of oxcarbazepine with ibuprofen and its additive interaction with etodolac provide new information about the combination pain treatment and could be explored further in patients with inflammatory pain. Adverse effect analysis of the combinations is necessary to verify possible clinical use of the mixtures. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis

    PubMed Central

    Gordic, S; Hodel, S; Simmen, H-P; Brueesch, M; Frauenfelder, T; Wanner, G; Sprengel, K

    2015-01-01

    Objective: To determine the number of imaging examinations, radiation dose and the time to complete trauma-related imaging in multiple trauma patients before and after introduction of whole-body CT (WBCT) into early trauma care. Methods: 120 consecutive patients before and 120 patients after introduction of WBCT into the trauma algorithm of the University Hospital Zurich were compared regarding the number and type of CT, radiography, focused assessment with sonography for trauma (FAST), additional CT examinations (defined as CT of the same body regions after radiography and/or FAST) and the time to complete trauma-related imaging. Results: In the WBCT cohort, significantly more patients underwent CT of the head, neck, chest and abdomen (p < 0.001) than in the non-WBCT cohort, whereas the number of radiographic examinations of the cervical spine, chest and pelvis and of FAST examinations were significantly lower (p < 0.001). There were no significant differences between cohorts regarding the number of radiographic examinations of the upper (p = 0.56) and lower extremities (p = 0.30). We found significantly higher effective doses in the WBCT (29.5 mSv) than in the non-WBCT cohort (15.9 mSv; p < 0.001), but fewer additional CT examinations for completing the work-up were needed in the WBCT cohort (p < 0.001). The time to complete trauma-related imaging was significantly shorter in the WBCT (12 min) than in the non-WBCT cohort (75 min; p < 0.001). Conclusion: Including WBCT in the initial work-up of trauma patients results in higher radiation doses, but fewer additional CT examinations are needed, and the time for completing trauma-related imaging is shorter. Advances in knowledge: WBCT in trauma patients is associated with a high radiation dose of 29.5 mSv. PMID:25594105

  19. Combination antiplatelet therapy with aspirin and clopidogrel: the role of antecedent and concomitant doses of aspirin. An analysis of 711 patients.

    PubMed

    Serebruany, Victor L; Malinin, Alex I; Atar, Dan

    2007-01-01

    Numerous randomized studies have shown that the combination of clopidogrel with aspirin yields better clinical outcomes than monotherapy in patients with acute vascular events. However, the impact of the aspirin dose on the antiplatelet potency of clopidogrel is unclear. We sought to compare the antiplatelet profile of aspirin 81 mg (n = 252) versus aspirin 325 mg (n = 459) before and during conventional clopidogrel loading (300 mg), and/or clopidogrel maintenance (75 mg/daily) therapy. Secondary post hoc analysis of an existing dataset consisting of 711 patients after coronary stenting (n = 601) and ischemic stroke (n = 110) treated previously with aspirin for at least 1 month, and then with aspirin + clopidogrel for at least 7 days was performed. Platelet assessments include conventional and whole blood aggregometry, rapid cartridge-based analyzers, and expression of platelet/endothelial cell adhesion molecule-1, P-selectin, and GPIIb/IIIa activity by flow cytometry measured before and after addition of clopidogrel. There was a small but consistent yet non-significant trend towards more potent platelet inhibition with aspirin 325 mg compared to aspirin 81 mg for every platelet activation parameter before addition of clopidogrel. However, after loading and/or 1 week of chronic treatment with clopidogrel + aspirin, measured platelet parameters became very similar between the groups, and identical for collagen-induced aggregation and PFA-100 analyzer readings. Before addition of clopidogrel, aspirin 325 mg has a tendency to provide stronger platelet inhibition than aspirin 81 mg. However, when clopidogrel and aspirin are used in combination, the higher aspirin dose does not translate into superior antiplatelet action. Given that the existing body of evidence supports the comparable efficacy and, particularly, superior safety of lower versus higher doses of aspirin, aspirin 81 mg should be the dose used in combination with clopidogrel. 2007 S. Karger AG, Basel

  20. Generation of the additional fluorescence radiation in the elastomeric shields used in computer tomography (CT).

    PubMed

    Szajerski, P; Zaborski, M; Bem, H; Baryn, W; Kusiak, E

    Two commercially available (EP, Z) and eight new elastomeric composites (M1-M4, G1-G4, of thickness ≈1 mm) containing mixtures of differing proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesised and examined as protective shields. The intensity of the X-ray fluorescence radiation generated in the typical elastomeric shields for CT, containing Bi and other heavy metal additives influence on the practical shielding properties. A method for assessing the radiation shielding properties of elastomeric composites used in CT examination procedures via X-ray spectrometry has been proposed. To measure the radiation reduction ability of the protective shields, the dose reduction factor (DRF) has been determined. The lead equivalents for the examined composites were within the ranges of 0.046-0.128 and 0.048-0.130 mm for 122.1 and 136.5 keV photons, respectively. The proposed method, unlike to the common approach, includes a dose contribution from the induced X-ray fluorescence radiation of the heavy metal elements in the protective shields. The results clearly indicate that among the examined compositions, the highest values DRF have been achieved with preparations containing Bi+W, Bi+W+Gd and Bi+W+Sb mixtures with gradually decreasing content of heavy metal additives in the following order: Bi, W, Gd and Sb. The respective values of DRF obtained for the investigated composites were 21, 28 and 27 % dose reduction for a 1 mm thick shield and 39 and ~50 % for a 2 mm thick layer (M1-M4).

  1. Clinical implementation of an exit detector-based dose reconstruction tool for helical tomotherapy delivery quality assurance.

    PubMed

    Deshpande, Shrikant; Xing, Aitang; Metcalfe, Peter; Holloway, Lois; Vial, Philip; Geurts, Mark

    2017-10-01

    The aim of this study was to validate the accuracy of an exit detector-based dose reconstruction tool for helical tomotherapy (HT) delivery quality assurance (DQA). Exit detector-based DQA tool was developed for patient-specific HT treatment verification. The tool performs a dose reconstruction on the planning image using the sinogram measured by the HT exit detector with no objects in the beam (i.e., static couch), and compares the reconstructed dose to the planned dose. Vendor supplied (three "TomoPhant") plans with a cylindrical solid water ("cheese") phantom were used for validation. Each "TomoPhant" plan was modified with intentional multileaf collimator leaf open time (MLC LOT) errors to assess the sensitivity and robustness of this tool. Four scenarios were tested; leaf 32 was "stuck open," leaf 42 was "stuck open," random leaf LOT was closed first by mean values of 2% and then 4%. A static couch DQA procedure was then run five times (once with the unmodified sinogram and four times with modified sinograms) for each of the three "TomoPhant" treatment plans. First, the original optimized delivery plan was compared with the original machine agnostic delivery plan, then the original optimized plans with a known modification applied (intentional MLC LOT error) were compared to the corresponding error plan exit detector measurements. An absolute dose comparison between calculated and ion chamber (A1SL, Standard Imaging, Inc., WI, USA) measured dose was performed for the unmodified "TomoPhant" plans. A 3D gamma evaluation (2%/2 mm global) was performed by comparing the planned dose ("original planned dose" for unmodified plans and "adjusted planned dose" for each intentional error) to exit detector-reconstructed dose for all three "Tomophant" plans. Finally, DQA for 119 clinical (treatment length <25 cm) and three cranio-spinal irradiation (CSI) plans were measured with both the ArcCHECK phantom (Sun Nuclear Corp., Melbourne, FL, USA) and the exit detector DQA tool to assess the time required for DQA and similarity between two methods. The measured ion chamber dose agreed to within 1.5% of the reconstructed dose computed by the exit detector DQA tool on a cheese phantom for all unmodified "Tomophant" plans. Excellent agreement in gamma pass rate (>95%) was observed between the planned and reconstructed dose for all "Tomophant" plans considered using the tool. The gamma pass rate from 119 clinical plan DQA measurements was 94.9% ± 1.5% and 91.9% ± 4.37% for the exit detector DQA tool and ArcCHECK phantom measurements (P = 0.81), respectively. For the clinical plans (treatment length <25 cm), the average time required to perform DQA was 24.7 ± 3.5 and 39.5 ± 4.5 min using the exit detector QA tool and ArcCHECK phantom, respectively, whereas the average time required for the 3 CSI treatments was 35 ± 3.5 and 90 ± 5.2 min, respectively. The exit detector tool has been demonstrated to be faster for performing the DQA with equivalent sensitivity for detecting MLC LOT errors relative to a conventional phantom-based QA method. In addition, comprehensive MLC performance evaluation and features of reconstructed dose provide additional insight into understanding DQA failures and the clinical relevance of DQA results. © 2017 American Association of Physicists in Medicine.

  2. Protective effect of chelerythrine against ethanol-induced gastric ulcer in mice.

    PubMed

    Li, Wei-Feng; Hao, Ding-Jun; Fan, Ting; Huang, Hui-Min; Yao, Huan; Niu, Xiao-Feng

    2014-02-05

    The quaternary benzo[c]phenanthridine alkaloid, chelerythrine (CHE), is of great practical and research interest because of its pronounced, widespread physiological effects, primarily antimicrobial and anti-inflammatory, arising from its ability to interact with proteins and DNA. Although CHE was originally shown to possess anti-inflammatory properties, its effects on acute gastric ulcer have not been previously explored. The aim of the present study is to evaluate the protective effect of CHE on ethanol induced gastric ulcer in mice. Administration of CHE at doses of 1, 5 and 10mg/kg bodyweight prior to ethanol ingestion dose-dependently inhibited gastric ulcer. The gastric mucosal lesion was assessed by ulcer area, gastric juice acidity, myeloperoxidase (MPO) activities, macroscopic and histopathological examinations. CHE significantly reduced the gastric ulcer index, myeloperoxidase activities, macroscopic and histological score in a dose-dependent manner. In addition, CHE also significantly inhibited nitric oxide (NO) concentration, pro-inflammatory interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α) level in serum and gastric mucosal in the mice exposed to ethanol induced ulceration in a dose-dependent manner. In addition, immunohistochemical analysis revealed that CHE markedly attenuated the overexpression of nuclear factor-κB in gastric mucosa of mice. It was concluded that CHE represents a potential therapeutic option to reduce the risk of gastric ulceration. In addition, acute toxicity study revealed no abnormal sign to the mice treated with CHE (15mg/kg). These findings suggest that the gastroprotective activity of CHE might contribute in adjusting the inflammatory cytokine by regulating the NF-κB signalling pathway. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Evaluation of forest decontamination using radiometric measurements.

    PubMed

    Cresswell, Alan J; Kato, Hiroaki; Onda, Yuichi; Nanba, Kenji

    2016-11-01

    An experiment has been conducted to evaluate the additional dose reduction by clear felling contaminated forestry in Fukushima Prefecture, Japan, and using the timber to cover the areas with wood chips. A portable gamma spectrometry system, comprising a backpack containing a 3 × 3″ NaI(Tl) detector with digital spectrometer and GPS receiver, has been used to map dose rate and radionuclide activity concentrations before, after and at stages during this experiment. The data show the effect of the different stages of the experiment on dose rate at different locations around the site. The spectrometric data have allowed the assessment of the contributions of natural and anthropogenic radionuclides to the dose rate at different parts of the site before and after the experiment. This has clearly demonstrated the value of radiometric methods in evaluating remediation, and the effect of other environmental processes. The value of spectrometric methods which directly measure radionuclide concentrations has also been shown, especially through the identification of the contribution of natural and anthropogenic activity to the measured dose rate. The experiment has shown that clearing trees and applying wood chips can reduce dose rates by 10-15% beyond that achieved by just clearing the forest litter and natural redistribution of radiocaesium. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. A nonlethal young domesticated ferret (Mustela putorius furo) model for studying pandemic influenza virus A/California/04/2009 (H1N1).

    PubMed

    Lednicky, John A; Croutch, Claire R; Lawrence, Sandra J; Hamilton, Sara B; Daniels, Deirdre E; Astroff, Barry

    2010-10-01

    Recent events have heightened the need for the rapid development of vaccines directed against pandemic influenza H1N1 viruses circulating during 2009 to 2010. The current study was conducted to establish a virus challenge dose for a subsequent CA/04 vaccine efficacy study in 3-mo-old domesticated ferrets. An additional consideration in using CA/04 in ferrets is the selection of endpoints on which to base the challenge dose, given the potential nonlethality of this particular model. Four doses ranging from 10(4) to 10(7) TCID(50) units of CA/04 per animal were administered by intranasal instillation to groups of male and female ferrets, and virus titers in nasal washes obtained 1, 3, and 5 d thereafter were determined in MDCK cells. Dosed ferrets developed clinically mild infections. Peak virus titers occurred on day 3 after instillation regardless of dose. Virus-treated ferrets had less weight gain than did untreated ferrets. In conclusion, 3-mo-old ferrets can be infected with doses as low as 10(4) TCID(50) units of CA/04, and virus titers in nasal washes and decreased body weight gain can be used to assess the course of nonlethal infection of 3-mo-old ferrets by CA/04.

  5. A Micronutrient Fortified Beverage Given at Different Dosing Frequencies Had Limited Impact on Anemia and Micronutrient Status in Filipino Schoolchildren.

    PubMed

    Angeles-Agdeppa, Imelda; Magsadia, Clarita R; Aaron, Grant J; Lloyd, Beate B; Hilmers, David C; Bhutta, Zulfiqar A

    2017-09-12

    This study evaluated the effects of a multi-micronutrient fortified juice drink given in different frequencies of consumption on hemoglobin (Hb) concentration of schoolchildren. Hb was measured in 2423 schoolchildren aged 6- to 9-years-old at baseline. All anemic children ( n = 246) were randomly allocated into groups: Daily dose (HD: high dose), 5X/week (MD: Moderate Dose), 3X/week (LD: Low Dose) and unfortified (Control). Pre- and post-study measurements of micronutrients were collected from 228 children. At the endpoint, significant Hb increases were observed in all groups, but there was no significant difference between groups. There was a significant reduction in anemia prevalence in all groups from 100% to 36% (Control), 30% (LD), 23% (MD) and 26% (HD). No dose-response effect was observed in Hb in this population. Most likely, this resulted from better than expected micronutrient status and lower than expected severity of anemia and micronutrient deficiencies in this cohort. It is unlikely that the addition of a fortified beverage to school feeding programs in this population would have a positive impact. Whether such an intervention would be cost-effective as a preventative approach needs to be assessed. This study demonstrates the importance of targeting such interventions to appropriate populations.

  6. Antibiotic Dosing in Continuous Renal Replacement Therapy.

    PubMed

    Shaw, Alexander R; Mueller, Bruce A

    2017-07-01

    Appropriate antibiotic dosing is critical to improve outcomes in critically ill patients with sepsis. The addition of continuous renal replacement therapy makes achieving appropriate antibiotic dosing more difficult. The lack of continuous renal replacement therapy standardization results in treatment variability between patients and may influence whether appropriate antibiotic exposure is achieved. The aim of this study was to determine if continuous renal replacement therapy effluent flow rate impacts attaining appropriate antibiotic concentrations when conventional continuous renal replacement therapy antibiotic doses were used. This study used Monte Carlo simulations to evaluate the effect of effluent flow rate variance on pharmacodynamic target attainment for cefepime, ceftazidime, levofloxacin, meropenem, piperacillin, and tazobactam. Published demographic and pharmacokinetic parameters for each antibiotic were used to develop a pharmacokinetic model. Monte Carlo simulations of 5000 patients were evaluated for each antibiotic dosing regimen at the extremes of Kidney Disease: Improving Global Outcomes guidelines recommended effluent flow rates (20 and 35 mL/kg/h). The probability of target attainment was calculated using antibiotic-specific pharmacodynamic targets assessed over the first 72 hours of therapy. Most conventional published antibiotic dosing recommendations, except for levofloxacin, reach acceptable probability of target attainment rates when effluent rates of 20 or 35 mL/kg/h are used. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  7. A Micronutrient Fortified Beverage Given at Different Dosing Frequencies Had Limited Impact on Anemia and Micronutrient Status in Filipino Schoolchildren

    PubMed Central

    Angeles-Agdeppa, Imelda; Magsadia, Clarita R.; Aaron, Grant J.; Lloyd, Beate B.; Hilmers, David C.; Bhutta, Zulfiqar A.

    2017-01-01

    This study evaluated the effects of a multi-micronutrient fortified juice drink given in different frequencies of consumption on hemoglobin (Hb) concentration of schoolchildren. Hb was measured in 2423 schoolchildren aged 6- to 9-years-old at baseline. All anemic children (n = 246) were randomly allocated into groups: Daily dose (HD: high dose), 5X/week (MD: Moderate Dose), 3X/week (LD: Low Dose) and unfortified (Control). Pre- and post-study measurements of micronutrients were collected from 228 children. At the endpoint, significant Hb increases were observed in all groups, but there was no significant difference between groups. There was a significant reduction in anemia prevalence in all groups from 100% to 36% (Control), 30% (LD), 23% (MD) and 26% (HD). No dose-response effect was observed in Hb in this population. Most likely, this resulted from better than expected micronutrient status and lower than expected severity of anemia and micronutrient deficiencies in this cohort. It is unlikely that the addition of a fortified beverage to school feeding programs in this population would have a positive impact. Whether such an intervention would be cost-effective as a preventative approach needs to be assessed. This study demonstrates the importance of targeting such interventions to appropriate populations. PMID:28895887

  8. Metformin and weight loss in obese women with polycystic ovary syndrome: comparison of doses.

    PubMed

    Harborne, Lyndal R; Sattar, Naveed; Norman, Jane E; Fleming, Richard

    2005-08-01

    Metformin treatment of women with polycystic ovary syndrome (PCOS) is widespread, as determined by studies with diverse patient populations. No comparative examination of weight changes or metabolite responses to different doses has been reported. The aim of this study was to determine whether different doses of metformin (1500 or 2550 mg/d) would have different effects on body weight, circulating hormones, markers of inflammation, and lipid profiles. The study included prospective cohorts randomized to two doses of metformin. The study was performed at a university teaching hospital with patients from gynecology/endocrinology clinics. The patients studied were obese (body mass index, 30 to <37 kg/m2; n = 42) and morbidly obese (body mass index, > or =37 kg/m2; n = 41) women with PCOS. Patients were randomized to two doses of metformin, and parameters were assessed after 4 and 8 months. The main outcome measures were changes in body mass, circulating hormones, markers of inflammation, and lipid profiles. Intention to treat analyses showed significant weight loss in both dose groups. Only the obese subgroup showed a dose relationship (1.5 and 3.6 kg in 1500- and 2550-mg groups, respectively; P = 0.04). The morbidly obese group showed similar reductions (3.9 and 3.8 kg) in both groups. Suppression of androstenedione was significant with both metformin doses, but there was no clear dose relationship. Generally, beneficial changes in lipid profiles were not related to dose. Weight loss is a feature of protracted metformin therapy in obese women with PCOS, with greater weight reduction potentially achievable with higher doses. Additional studies are required to determine whether other aspects of the disorder may benefit from the higher dose of metformin.

  9. Dynamic CT for Parathyroid Adenoma Detection: How Does Radiation Dose Compare With Nuclear Medicine?

    PubMed

    Czarnecki, Caroline A; Einsiedel, Paul F; Phal, Pramit M; Miller, Julie A; Lichtenstein, Meir; Stella, Damien L

    2018-05-01

    Dynamic CT is increasingly used for preoperative localization of parathyroid adenomas, but concerns remain about the radiation effective dose of CT compared with that of 99m Tc-sestamibi scintigraphy. The purpose of this study was to compare the radiation dose delivered by three-phase dynamic CT with that delivered by 99m Tc-sestamibi SPECT/CT performed in accordance with our current protocols and to assess the possible reduction in effective dose achieved by decreasing the scan length (i.e., z-axis) of two phases of the dynamic CT protocol. The effective dose of a 99m Tc-sestamibi nuclear medicine parathyroid study performed with and without coregistration CT was calculated and compared with the effective dose of our current three-phase dynamic CT protocol as well as a proposed protocol involving CT with reduced scan length. The median effective dose for a 99m Tc-sestamibi nuclear medicine study was 5.6 mSv. This increased to 12.4 mSv with the addition of coregistration CT, which is higher than the median effective dose of 9.3 mSv associated with the dynamic CT protocol. Reducing the scan length of two phases in the dynamic CT protocol could reduce the median effective dose to 6.1 mSv, which would be similar to that of the dose from the 99m Tc-sestamibi study alone. Dynamic CT used for the detection of parathyroid adenoma can deliver a lower radiation dose than 99m Tc-sestamibi SPECT/CT. It may be possible to reduce the dose further by decreasing the scan length of two of the phases, although whether this has an impact on accuracy of the localization needs further investigation.

  10. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jannik, G. T.; Dixon, K. L.

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  11. Bioaccessibility of Fukushima-Accident-Derived Cs in Soils and the Contribution of Soil Ingestion to Radiation Doses in Children.

    PubMed

    Takahara, Shogo; Ikegami, Maiko; Yoneda, Minoru; Kondo, Hitoshi; Ishizaki, Azusa; Iijima, Masashi; Shimada, Yoko; Matsui, Yasuto

    2017-07-01

    Ingestion of contaminated soil is one potential internal exposure pathway in areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Doses from this pathway can be overestimated if the availability of radioactive nuclides in soils for the gastrointestinal tract is not considered. The concept of bioaccessibility has been adopted to evaluate this availability based on in vitro tests. This study evaluated the bioaccessibility of radioactive cesium from soils via the physiologically-based extraction test (PBET) and the extractability of those via an extraction test with 1 mol/L of hydrochloric acid (HCl). The bioaccessibility obtained in the PBET was 5.3% ± 1%, and the extractability in the tests with HCl was 16% ± 3%. The bioaccessibility was strongly correlated with the extractability. This result indicates the possibility that the extractability in HCl can be used as a good predictor of the bioaccessibility with PBET. In addition, we assessed the doses to children from the ingestion of soil via hand-to-mouth activity based on our PBET results using a probabilistic approach considering the spatial distribution of radioactive cesium in Date City in Fukushima Prefecture and the interindividual differences in the surveyed amounts of soil ingestion in Japan. The results of this assessment indicate that even if children were to routinely ingest a large amount of soil with relatively high contamination, the radiation doses from this pathway are negligible compared with doses from external exposure owing to deposited radionuclides in Fukushima Prefecture. © 2016 Society for Risk Analysis.

  12. Dose-Response Association Between Physical Activity and Incident Hypertension: A Systematic Review and Meta-Analysis of Cohort Studies.

    PubMed

    Liu, Xuejiao; Zhang, Dongdong; Liu, Yu; Sun, Xizhuo; Han, Chengyi; Wang, Bingyuan; Ren, Yongcheng; Zhou, Junmei; Zhao, Yang; Shi, Yuanyuan; Hu, Dongsheng; Zhang, Ming

    2017-05-01

    Despite the inverse association between physical activity (PA) and incident hypertension, a comprehensive assessment of the quantitative dose-response association between PA and hypertension has not been reported. We performed a meta-analysis, including dose-response analysis, to quantitatively evaluate this association. We searched PubMed and Embase databases for articles published up to November 1, 2016. Random effects generalized least squares regression models were used to assess the quantitative association between PA and hypertension risk across studies. Restricted cubic splines were used to model the dose-response association. We identified 22 articles (29 studies) investigating the risk of hypertension with leisure-time PA or total PA, including 330 222 individuals and 67 698 incident cases of hypertension. The risk of hypertension was reduced by 6% (relative risk, 0.94; 95% confidence interval, 0.92-0.96) with each 10 metabolic equivalent of task h/wk increment of leisure-time PA. We found no evidence of a nonlinear dose-response association of PA and hypertension ( P nonlinearity =0.094 for leisure-time PA and 0.771 for total PA). With the linear cubic spline model, when compared with inactive individuals, for those who met the guidelines recommended minimum level of moderate PA (10 metabolic equivalent of task h/wk), the risk of hypertension was reduced by 6% (relative risk, 0.94; 95% confidence interval, 0.92-0.97). This meta-analysis suggests that additional benefits for hypertension prevention occur as the amount of PA increases. © 2017 American Heart Association, Inc.

  13. Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose.

    PubMed

    Jiménez-Juan, Laura; Nguyen, Elsie T; Wintersperger, Bernd J; Moshonov, Hadas; Crean, Andrew M; Deva, Djeven P; Paul, Narinder S; Torres, Felipe S

    2013-01-01

    The purpose of this study was to evaluate the effect of intravenous (i.v.) metoprolol after a suboptimal heart rate (HR) response to oral metoprolol (75-150 mg) on HR control, image quality (IQ) and radiation dose during coronary CTA using 320-MDCT. Fifty-three consecutive patients who failed to achieve a target HR of < 60 bpm after an oral dose of metoprolol and required supplementary i.v. metoprolol (5-20 mg) prior to coronary CTA were evaluated. Patients with HR < 60 bpm during image acquisition were defined as responders (R) and those with HR ≥ 60 bpm as non-responders (NR). Two observers assessed IQ using a 3-point scale (1-2, diagnostic and 3, non-diagnostic). Effective dose (ED) was estimated using dose-length product and a 0.014 mSV/mGy.cm conversion factor. Baseline characteristics and HR on arrival were similar in the two groups. 58% of patients didn't achieve the target HR after receiving i.v. metoprolol (NR). R had a significantly higher HR reduction after oral (mean HR 63.9 ± 4.5 bpm vs. 69.6 ± 5.6 bpm) (p < 0.005) and i.v. (mean HR 55.4 ± 3.9 bpm vs. 67.4 ± 5.3 bpm) (p < 0.005) doses of metoprolol. Studies from NR showed a significantly higher ED in comparison to R (8.0 ± 2.9 vs. 6.1 ± 2.2 mSv) (p = 0.016) and a significantly higher proportion of non-diagnostic coronary segments (9.2 vs. 2.5%) (p < 0.001). 58% of patients who do not achieve a HR of <60 bpm prior to coronary CTA with oral fail to respond to additional i.v. metoprolol and have studies with higher radiation dose and worse image quality.

  14. Ultralow Dose of Naloxone as an Adjuvant to Intrathecal Morphine Infusion Improves Perceived Quality of Sleep but Fails to Alter Persistent Pain

    PubMed Central

    Lundborg, Christopher; Bjersing, Jan; Dahm, Peter; Hansson, Elisabeth; Biber, Björn

    2015-01-01

    Introduction: This randomized, cross-over, double-blind, controlled study of continuous intrathecal morphine administration in patients with severe, long-term pain addresses whether the supplementation of low doses of naloxone in this setting is associated with beneficial clinical effects. Methods: All of the study subjects (n=11) provided informed consent and were recruited from a subset of patients who were already undergoing long-term treatment with continuous intrathecal morphine because of difficult-to-treat pain. The patients were (in a randomized order) also given intrathecal naloxone (40 ng/24 h or 400 ng/24 h). As control, the patients’ ordinary dose of morphine without any additions was used. The pain (Numeric Rating Scale, NRS) during activity, perceived quality of sleep, level of activity, and quality of life as well as the levels of several proinflammatory and anti-inflammatory cytokines in the blood were assessed. The prestudy pain (NRS during activity) in the study group ranged from 3 to 10. Results: A total of 64% of the subjects reported improved quality of sleep during treatment with naloxone at a dose of 40 ng per 24 hours as compared with 9% with sham treatment (P=0.024). Although not statistically significant, pain was reduced by 2 NRS steps or more during supplemental treatment with naloxone in 36% of subjects when using the 40 ng per 24 hours dose and in 18% of the subjects when using naloxone 400 ng per 24 hours dose. The corresponding percentage among patients receiving unaltered treatment was 27%. Conclusions: To conclude, the addition of an ultralow dose of intrathecal naloxone (40 ng/24 h) to intrathecal morphine infusion in patients with severe, persistent pain improved perceived quality of sleep. We were not able to show any statistically significant effects of naloxone on pain relief, level of activity, or quality of life. PMID:25629634

  15. Direct Measurement of Perchlorate Exposure Biomarkers in a Highly Exposed Population: A Pilot Study

    PubMed Central

    Wong, Michelle; Copan, Lori; Olmedo, Luis; Patton, Sharyle; Haas, Robert; Atencio, Ryan; Xu, Juhua; Valentin-Blasini, Liza

    2011-01-01

    Exposure to perchlorate is ubiquitous in the United States and has been found to be widespread in food and drinking water. People living in the lower Colorado River region may have perchlorate exposure because of perchlorate in ground water and locally-grown produce. Relatively high doses of perchlorate can inhibit iodine uptake and impair thyroid function, and thus could impair neurological development in utero. We examined human exposures to perchlorate in the Imperial Valley among individuals consuming locally grown produce and compared perchlorate exposure doses to state and federal reference doses. We collected 24-hour urine specimen from a convenience sample of 31 individuals and measured urinary excretion rates of perchlorate, thiocyanate, nitrate, and iodide. In addition, drinking water and local produce were also sampled for perchlorate. All but two of the water samples tested negative for perchlorate. Perchlorate levels in 79 produce samples ranged from non-detect to 1816 ppb. Estimated perchlorate doses ranged from 0.02 to 0.51 µg/kg of body weight/day. Perchlorate dose increased with the number of servings of dairy products consumed and with estimated perchlorate levels in produce consumed. The geometric mean perchlorate dose was 70% higher than for the NHANES reference population. Our sample of 31 Imperial Valley residents had higher perchlorate dose levels compared with national reference ranges. Although none of our exposure estimates exceeded the U. S. EPA reference dose, three participants exceeded the acceptable daily dose as defined by bench mark dose methods used by the California Office of Environmental Health Hazard Assessment. PMID:21394205

  16. Cumulative trauma and posttraumatic stress disorder among children exposed to the 9/11 World Trade Center attack.

    PubMed

    Mullett-Hume, Elizabeth; Anshel, Daphne; Guevara, Vivianne; Cloitre, Marylene

    2008-01-01

    Two and one-half years after the September 11, 2001 World Trade Center attack, 204 middle school students in an immigrant community located near Ground Zero were assessed for posttraumatic stress disorder (PTSD) symptoms as influenced by "dose" of exposure to the attack and accumulated lifetime traumas. Ninety percent of students reported at least one traumatic event other than 9/11 (e.g., community violence) with an average of 4 lifetime events reported. An interaction was obtained such that the dose-response effect depended on presence of other traumas. Among students with the lowest number of additional traumas, the usual dose-response pattern of increasing PTSD symptoms with increasing 9/11 exposure was observed; among those with medium to high cumulative life trauma, PTSD symptoms were substantially higher and uniformly so regardless of 9/11 exposure dose. Results suggest that traumas that precede or follow mass violence often have as much as if not greater impact on long-term symptom severity than high-dose exposure to the event. Implications regarding the presence of continuing or previous trauma exposure for postdisaster and early intervention policies are discussed. (c) 2008 APA, all rights reserved

  17. Heterogeneity of Rotavirus Vaccine Efficacy Among Infants in Developing Countries.

    PubMed

    Gruber, Joann F; Hille, Darcy A; Liu, G Frank; Kaplan, Susan S; Nelson, Micki; Goveia, Michelle G; Mast, T Christopher

    2017-01-01

    Rotavirus is the leading cause of severe diarrhea worldwide in young children. Although rotavirus vaccine efficacy is high in developed countries, efficacy is lower in developing countries. Here, we investigated heterogeneity of rotavirus vaccine efficacy by infant characteristics in developing countries. An exploratory, post hoc analysis was conducted using randomized controlled trial data of the pentavalent rotavirus vaccine (RV5) conducted in Africa and Asia (NCT00362648). Infants received either 3 doses of vaccine/placebo and were followed for up to 2 years. Within subgroups, vaccine efficacies and 95% confidence intervals (CIs) against rotavirus gastroenteritis (RVGE) were estimated using Poisson regression. We assessed heterogeneity of efficacy by age at first dose, gender, breastfeeding status and nutrition status. African children receiving the first dose at <8 weeks had lower efficacy (23.7%; 95% CI: -8.2%-46.3%) than those vaccinated at ≥8 weeks (59.1%; 95% CI: 34.0%-74.6%). Marginally statistically significant differences were observed by age at first dose, gender and underweight status in Ghana and gender in Asian countries. Heterogeneity of efficacy was observed for age at first dose in African countries. This was an exploratory analysis; additional studies are needed to validate these results.

  18. Computed tomography and patient risk: Facts, perceptions and uncertainties

    PubMed Central

    Power, Stephen P; Moloney, Fiachra; Twomey, Maria; James, Karl; O’Connor, Owen J; Maher, Michael M

    2016-01-01

    Since its introduction in the 1970s, computed tomography (CT) has revolutionized diagnostic decision-making. One of the major concerns associated with the widespread use of CT is the associated increased radiation exposure incurred by patients. The link between ionizing radiation and the subsequent development of neoplasia has been largely based on extrapolating data from studies of survivors of the atomic bombs dropped in Japan in 1945 and on assessments of the increased relative risk of neoplasia in those occupationally exposed to radiation within the nuclear industry. However, the association between exposure to low-dose radiation from diagnostic imaging examinations and oncogenesis remains unclear. With improved technology, significant advances have already been achieved with regards to radiation dose reduction. There are several dose optimization strategies available that may be readily employed including omitting unnecessary images at the ends of acquired series, minimizing the number of phases acquired, and the use of automated exposure control as opposed to fixed tube current techniques. In addition, new image reconstruction techniques that reduce radiation dose have been developed in recent years with promising results. These techniques use iterative reconstruction algorithms to attain diagnostic quality images with reduced image noise at lower radiation doses. PMID:28070242

  19. Is the Linear No-Threshold Dose-Response Paradigm Still Necessary for the Assessment of Health Effects of Low Dose Radiation?

    PubMed Central

    2016-01-01

    Inevitable human exposure to ionizing radiation from man-made sources has been increased with the proceeding of human civilization and consequently public concerns focus on the possible risk to human health. Moreover, Fukushima nuclear power plant accidents after the 2011 East-Japan earthquake and tsunami has brought the great fear and anxiety for the exposure of radiation at low levels, even much lower levels similar to natural background. Health effects of low dose radiation less than 100 mSv have been debated whether they are beneficial or detrimental because sample sizes were not large enough to allow epidemiological detection of excess effects and there was lack of consistency among the available experimental data. We have reviewed an extensive literature on the low dose radiation effects in both radiation biology and epidemiology, and highlighted some of the controversies therein. This article could provide a reasonable view of utilizing radiation for human life and responding to the public questions about radiation risk. In addition, it suggests the necessity of integrated studies of radiobiology and epidemiology at the national level in order to collect more systematic and profound information about health effects of low dose radiation. PMID:26908982

  20. Decorporation Approach after Rat Lung Contamination with Plutonium: Evaluation of the Key Parameters Influencing the Efficacy of a Protracted Chelation Treatment.

    PubMed

    Grémy, Olivier; Coudert, Sylvie; Renault, Daniel; Miccoli, Laurent

    2017-11-01

    While the efficacy of a protracted zinc (Zn)- or calcium (Ca)-diethylenetriaminepentaacetic acid (DTPA) treatment in reducing transuranic body burden has already been demonstrated, questions about therapeutic variables remain. In response to this, we designed animal experiments primarily to assess both the effect of fractionation of a given dose and the effect of the frequency of dose fraction, with the same total dose. In our study, rats were contaminated intravenously with plutonium (Pu) then treated several days later with Ca-DTPA given at once or in various split-dose regimens cumulating to the same total dose and spread over several days. Similar efficacies were induced by the injection of the total dose or by splitting the dose in several smaller doses, independent of the number of doses and the dose level per injection. In a second study, rats were pulmonary contaminated, and three weeks later they received a Ca-DTPA dose 11-fold higher than the maximal daily recommended dose, administered either as a single bolus or as numerous multiple injections cumulating to the same dose, based on different injection frequency schedules. Independent of frequency schedule, the various split-dose regimens spread over weeks/months were as efficient as single delivery of the total dose in mobilizing lung plutonium, and had a therapeutic advantage for removal of retained hepatic and bone plutonium burdens. We concluded that cumulative dose level was a therapeutic variable of greater importance than the distribution of split doses for the success of a repeated treatment regimen on retained tissue plutonium. In addition, pulmonary administration of clodronate, which aims at killing alveolar macrophages and subsequently releasing their plutonium content, and which is associated with a continuous Ca-DTPA infusion regimen, suggested that the efficacy of injected Ca-DTPA in decorporating lung deposit is limited, due to its restricted penetration into alveolar macrophages and not because plutonium, as a physicochemical form, is unavailable for chelation.

  1. Relationship between paediatric CT scans and subsequent risk of leukaemia and brain tumours: assessment of the impact of underlying conditions.

    PubMed

    Berrington de Gonzalez, Amy; Salotti, Jane A; McHugh, Kieran; Little, Mark P; Harbron, Richard W; Lee, Choonsik; Ntowe, Estelle; Braganza, Melissa Z; Parker, Louise; Rajaraman, Preetha; Stiller, Charles; Stewart, Douglas R; Craft, Alan W; Pearce, Mark S

    2016-02-16

    We previously reported evidence of a dose-response relationship between ionising-radiation exposure from paediatric computed tomography (CT) scans and the risk of leukaemia and brain tumours in a large UK cohort. Underlying unreported conditions could have introduced bias into these findings. We collected and reviewed additional clinical information from radiology information systems (RIS) databases, underlying cause of death and pathology reports. We conducted sensitivity analyses excluding participants with cancer-predisposing conditions or previous unreported cancers and compared the dose-response analyses with our original results. We obtained information from the RIS and death certificates for about 40% of the cohort (n∼180 000) and found cancer-predisposing conditions in 4 out of 74 leukaemia/myelodysplastic syndrome (MDS) cases and 13 out of 135 brain tumour cases. As these conditions were unrelated to CT exposure, exclusion of these participants did not alter the dose-response relationships. We found evidence of previous unreported cancers in 2 leukaemia/MDS cases, 7 brain tumour cases and 232 in non-cases. These previous cancers were related to increased number of CTs. Exclusion of these cancers reduced the excess relative risk per mGy by 15% from 0.036 to 0.033 for leukaemia/MDS (P-trend=0.02) and by 30% from 0.023 to 0.016 (P-trend<0.0001) for brain tumours. When we included pathology reports we had additional clinical information for 90% of the cases. Additional exclusions from these reports further reduced the risk estimates, but this sensitivity analysis may have underestimated risks as reports were only available for cases. Although there was evidence of some bias in our original risk estimates, re-analysis of the cohort with additional clinical data still showed an increased cancer risk after low-dose radiation exposure from CT scans in young patients.

  2. Radiation exposure to the eye lens of orthopaedic surgeons during various orthopaedic procedures.

    PubMed

    Romanova, K; Vassileva, J; Alyakov, M

    2015-07-01

    The aim of the present study was to assess the radiation dose to the eye lens of orthopaedic surgeons during various orthopaedic procedures and to make efforts to ensure that radiation protection is optimised. The study was performed for Fractura femoris and Fractura cruris procedures performed in orthopaedic operating theatres, as well as for fractures of wrist, ankle and hand/shoulder performed in the emergency trauma room. The highest mean value of the eye lens dose of 47.2 μSv and higher mean fluoroscopy time of 3 min, as well as the corresponding highest maximum values of 77.1 μSv and 5.0 min were observed for the Fractura femoris procedure performed with the Biplanar 500e fluoroscopy systems. At a normal workload, the estimated mean annual dose values do not exceed the annual occupational dose limit for the lens of eye, but at a heavy workload in the department, this dose limit could be achieved or exceeded. The use of protective lead glasses is recommended as they could reduce the radiation exposure of the lens of the eye. The phantom measurements demonstrated that the use of half-dose mode could additionally reduce dose to the operator's eye lens. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Thermoluminescence dosimetry and its applications in medicine--Part 2: History and applications.

    PubMed

    Kron, T

    1995-03-01

    Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of microGy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. Therefore TLD is a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review (Australas. Phys. Eng. Sci. Med. 17: 175-199, 1994).

  4. [Blood amylase: a biological marker in irradiation accidents? Preliminary results obtained at the Gustave-Roussy Institut (GRI) and a literature review].

    PubMed

    Hennequin, C; Cosset, J M; Cailleux, P E; Girinsky, T; Ganem, G; Hubert, D; Comoy, E; Dutreix, J

    1989-01-01

    The retrospective evaluation of the dose after an irradiation accident is of paramount importance; it allows an adequate selection of patients and the most appropriate treatment can then be proposed. Classical physical dosimetry often lacks precision for dose assessment in such accidents. Cytogenetics, usually more reliable, is not 100% accurate and cannot be used in some particular instances. At the Institut Gustave-Roussy, we studied amylasemia in 15 patients who received a total body irradiation (TBI) for bone marrow grafting, at various dose levels (10, 2 and 1.35 Gy). Hyperamylasemia was found to be constant and dose-dependent. Ten additional patients given a localized irradiation of 2 Gy in the Waldeyer ring had a similar rise in amylasemia as did TBI patients who had received the same dose. In contrast, 13 patients given a pancreatic irradiation (as part of a localized abdominal irradiation) did not show any increase in amylasemia. This study seems to confirm reported data, which suggested that post-TBI hyperamylasemia is almost only related to salivary gland irradiation. Amylasemia could possibly be used as a "biological dosimeter"; however, the dose-effect relationship should be more precisely defined, as well as individual variations. Moreover, the definition of a "threshold-dose" below which hyperamylasemia can never be detected, would be of interest for radioprotection.

  5. Evaluation of an intragastric challenge model for Shigella dysenteriae 1 in rhesus monkeys (Macaca mulatta) for the pre-clinical assessment of Shigella vaccine formulations

    PubMed Central

    Islam, Dilara; Ruamsap, Nattaya; Khantapura, Patchariya; Aksomboon, Ajchara; Srijan, Apichai; Wongstitwilairoong, Boonchai; Bodhidatta, Ladaporn; Gettayacamin, Montip; Venkatesan, Malabi M; Mason, Carl J

    2014-01-01

    Shigellosis is a worldwide disease, characterized by abdominal pain, fever, vomiting, and the passage of blood- and mucus-streaked stools. Rhesus monkeys and other primates are the only animals that are naturally susceptible to shigellosis. A suitable animal model is required for the pre-clinical evaluation of vaccines candidates. In this study, the minimal dose of Shigella dysenteriae1 1617 strain required to produce dysentery in four of five (80% attack rate) monkeys using an escalating dose range for three groups [2 × 108, 2 × 109 and 2 × 1010 colony forming unit (CFU)] was determined. In addition, the monkeys were re-infected. The identified optimal challenge dose was 2 × 109 CFU; this dose elicited 60% protection in monkeys when they were re-challenged with a one log higher dose (2 × 1010 CFU). The challenge dose, 2 × 1010 CFU, produced severe dysentery in all monkeys, with one monkey dying within 24 h, elicited 100% protection when re-challenged with the same dose. All monkeys exhibited immune responses. This study concludes that the rhesus monkey model closely mimics the disease and immune response seen in humans and is a suitable animal model for the pre-clinical evaluation of Shigella vaccine candidates. Prior infection with the 1617 strain can protect monkeys against subsequent re-challenges with homologous strains. PMID:24028276

  6. Effect of farmyard manure rate on water erosion of a Mediterranean soil: determination of the critical point of inefficacy

    NASA Astrophysics Data System (ADS)

    Annabi, Mohamed; Bahri, Haithem; Cheick M'Hamed, Hatem; Hermessi, Taoufik

    2016-04-01

    Intensive cultivation of soils, using multiple soil tillage, led to the decrease of their organic matter content and structural stability in several cultivated area of the Mediterranean countries. In these degraded soils, the addition of organic products, traditionally the animal manure, should improve soil health among them the resistance of soil to water erosion. The aim of this study was to evaluate after 1 year of the addition to a cambisoil different doses of farmyard manure on soil organic matter content, on microbial activity and on aggregate stability (proxy to soil resistance to water erosion). The statistical process (bilinear model) was used to found a point at which the addition of the organic product no longer influences the soil resistance to erosion. The farmyard manure issued from a cow breeding was composted passively during 4 months and used to amend a small plots of a cultivated cambisol (silty-clay texture, 0.9% TOC) located in the northeast of Tunisia (Morneg region). The manure was intimately incorporate to the soil. The manure organic matter content was 31%, and its isohumic coefficient was 49%. Twelve dose of manure were tested: from 0 to 220 t C.ha-1. The experiment was started on September 2011. In November 2012, soil sampling was done and soil organic carbon content (Walkley-Black method) and soil aggregate stability (wet method of Le Bissonnais) were assessed. A laboratory incubations of soil+manure mixtures, with the same proportions as tested in the field conditions, was carried at 28°C and at 75% of the mixture field capacity water retention. Carbon mineralization was monitored during three months incubation. Results show that the addition of farmyard manure stimulated the microbial activity proportionally to the added dose. This activation is due to the presence of easily biodegradable carbon in the manure, which increases with increasing manure dose. On the other hand, the addition of manure increased the aggregate stability with the manure dose increasing. This aggregate stabilization is due to the stimulation of microbial activity (r= 0.72, n=12) which can improves the aggregate stability by increasing the aggregate cohesion by adhesive substances such as the polysaccharides and by the enmeshment of aggregate by fungal hyphea. The increase of organic matter content due to manure addition contributes also to aggregate stabilization with a high regression slope with the first manure doses (less then 120 t C.ha-1). Using a bi-linear model, reach 2.3% of soil organic carbon seems to be a critical level from which the aggregate stability evolves little.

  7. Axitinib in combination with pembrolizumab in patients with advanced renal cell cancer: a non-randomised, open-label, dose-finding, and dose-expansion phase 1b trial.

    PubMed

    Atkins, Michael B; Plimack, Elizabeth R; Puzanov, Igor; Fishman, Mayer N; McDermott, David F; Cho, Daniel C; Vaishampayan, Ulka; George, Saby; Olencki, Thomas E; Tarazi, Jamal C; Rosbrook, Brad; Fernandez, Kathrine C; Lechuga, Mariajose; Choueiri, Toni K

    2018-03-01

    Previous studies combining PD-1 checkpoint inhibitors with tyrosine kinase inhibitors of the VEGF pathway have been characterised by excess toxicity, precluding further development. We hypothesised that axitinib, a more selective VEGF inhibitor than others previously tested, could be combined safely with pembrolizumab (anti-PD-1) and yield antitumour activity in patients with treatment-naive advanced renal cell carcinoma. In this ongoing, open-label, phase 1b study, which was done at ten centres in the USA, we enrolled patients aged 18 years or older who had advanced renal cell carcinoma (predominantly clear cell subtype) with their primary tumour resected, and at least one measureable lesion, Eastern Cooperative Oncology Group performance status 0-1, controlled hypertension, and no previous systemic therapy for renal cell carcinoma. Eligible patients received axitinib plus pembrolizumab in a dose-finding phase to estimate the maximum tolerated dose, and additional patients were enrolled into a dose-expansion phase to further establish safety and determine preliminary efficacy. Axitinib 5 mg was administered orally twice per day with pembrolizumab 2 mg/kg given intravenously every 3 weeks. We assessed safety in all patients who received at least one dose of axitinib or pembrolizumab; antitumour activity was assessed in all patients who received study treatment and had an adequate baseline tumour assessment. The primary endpoint was investigator-assessed dose-limiting toxicity during the first two cycles (6 weeks) to estimate the maximum tolerated dose and recommended phase 2 dose. This study is registered with ClinicalTrials.gov, number NCT02133742. Between Sept 23, 2014, and March 25, 2015, we enrolled 11 patients with previously untreated advanced renal cell carcinoma to the dose-finding phase and between June 3, 2015, and Oct 13, 2015, we enrolled 41 patients to the dose-expansion phase. All 52 patients were analysed together. No unexpected toxicities were observed. Three dose-limiting toxicities were reported in the 11 patients treated during the 6-week observation period (dose-finding phase): one patient had a transient ischaemic attack and two patients were only able to complete less than 75% of the planned axitinib dose because of treatment-related toxicity. At the data cutoff date (March 31, 2017), 25 (48%) patients were still receiving study treatment. Grade 3 or worse treatment-related adverse events occurred in 34 (65%) patients; the most common included hypertension (n=12 [23%]), diarrhoea (n=5 [10%]), fatigue (n=5 [10%]), and increased alanine aminotransferase concentration (n=4 [8%]). The most common potentially immune-related adverse events (probably related to pembrolizumab) included diarrhoea (n=15 [29%]), increased alanine aminotransferase concentration (n=9 [17%]) or aspartate aminotransferase concentration (n=7 [13%]), hypothyroidism (n=7 [13%]), and fatigue (n=6 [12%]). 28 (54%) patients had treatment-related serious adverse events. At data cutoff, 38 (73%; 95% CI 59·0-84·4) patients achieved an objective response (complete or partial response). The treatment combination of axitinib plus pembrolizumab is tolerable and shows promising antitumour activity in patients with treatment-naive advanced renal cell carcinoma. Whether or not the combination works better than a sequence of VEGF pathway inhibition followed by an anti-PD-1 therapy awaits the completion of a phase 3 trial comparing axitinib plus pembrolizumab with sunitinib monotherapy (NCT02853331). Pfizer Inc. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Effects of inorganic amendments (urea, gypsum) on seed germination and seedling recruitment of 20 native plant species used in dryland restoration

    NASA Astrophysics Data System (ADS)

    Bateman, Amber; E Erickson, Todd; Merritt, David J.; Muñoz-Rojas, Miriam

    2017-04-01

    Introduction Soil health and functionality are major determining factors for restoration of degraded arid and semi-arid ecosystems. These highly nutrient impoverished soil substrates with low water retention capabilities dictate plant growth and survival in these landscapes that are subject to variable rainfall event and high temperatures (Muñoz-Rojas et al., 2016). Anthropogenic disturbances derived from mining activities have contributed to the degradation of soil functionality and have altered plant-soil-water interactions. With unknown positive or negative rehabilitation outcomes, inorganic amendments in the form of urea and gypsum are commonly added to reconstructed soil substrates disturbed by mining to replenish soil nutrients (nitrogen) and improve soil water holding capacity to improve seedling establishment and survival. Methods Using existing protocols for amendment addition to soil substrates, two experiments assessed the effects of urea and gypsum at multiple doses in reconstructed soil substrates (topsoil (TS), waste (W) and, 50:50 blend of both materials (TW) to evaluate its effectiveness as a supplement to improve seed germination, seedling recruitment and plant growth. In the first experiment, 20 species native to the resource-rich biodiverse Pilbara region of Western Australia were grown in 30 °C glasshouse facilities under well-watered conditions for three weeks with seedling emergence scored daily. At the end of the trial, seedlings were harvested and biomass was assessed. In the second experiment, five of the original 20 species (e.g. Acacia bivenosa, Gossypium robinsonii, Eucalyptus gamophylla, Triodia wiseana and, Senna notabilis) were assessed for germination in amended soils by burying nylon sachets in the reconstructed substrates. After three weeks, the sachets were retrieved and seeds were assessed for germination (i.e. radicle emergence was evident). Results and Discussion Total emergence and biomass of seedlings was negatively affected by higher doses of gypsum and urea amendments. In the lower dose treatments, however, the total biomass of seedlings showed a positive effect for species from the Amaranthaceae. There was no apparent effect on species from the Fabaceae, Malvaeceae, Myrtaceae, and Poaceae families. Small doses of the amendments had a positive impact on the seed germination for three of the five evaluated species (Acacia bivenosa, Triodia wiseana and, Senna notabilis). Yet, despite the addition of soil amendments there was a high rate of mortality between the germination and emergence phases, a common occurrence in arid zone species subject to extreme environmental conditions (James et al., 2011). Seedling emergence of Acacia bivenosa and Triodia wiseana in TW and W substrates with low doses of urea achieved levels comparable to emergence in topsoil. Overall, responses to the inorganic amendments varied considerably across species and long-term field studies are required to assess plant responses in a restoration setting. Nevertheless, the findings of this suggest that the addition of these N-based inorganic amendments at low concentrations will benefit some plant species and improve arid zone restoration. References James JJ, Svejcar TJ, Rinella MJ. 2011. Demographic processes limiting seedling recruitment in arid grassland restoration. Journal of Applied Ecology, 48, 961-969 Muñoz-Rojas M, Erickson TE, Martini D, Dixon KW, Merritt DJ. 2016. Climate and soil factors influencing seedling recruitment of plant species used for dryland restoration. SOIL, 2, 1-11, DOI: 10.5194/soil-2016-25

  9. Are additive effects of dietary surfactants on intestinal tight junction integrity an overlooked human health risk? - A mixture study on Caco-2 monolayers.

    PubMed

    Glynn, Anders; Igra, Annachiara Malin; Sand, Salomon; Ilbäck, Nils Gunnar; Hellenäs, Karl Erik; Rosén, Johan; Aspenström-Fagerlund, Bitte

    2017-08-01

    Surfactants may cause dysfunction of intestinal tight junctions (TJs), which is a common feature of intestinal autoimmune diseases. Effects of dietary surfactants on TJ integrity, measured as trans-epithelial resistance (TEER), were studied in Caco-2 cell monolayers. Cytotoxicity was assessed as apical LDH leakage. Monolayers were apically exposed for 60 min to the dietary surfactants solanine and chaconine (SC, potato glycoalkaloids, 0-0.25 mM), perfluorooctane sulfonic acid (PFOS, industrial contaminant, 0-0.8 mM), and sucrose monolaurate (SML, food emulsifier E 473, 0-2.0 mM) separately and as a mixture. Dose-response modelling of TEER EC 50 showed that SC were 2.7- and 12-fold more potent than PFOS and SML, respectively. The mixture was composed of 1 molar unit SC, 2.7 units PFOS and 12 units SML ("SC TEER equivalent" proportions 1:1:1). Mixture exposure (0-0.05 mM SC equivalents) dose-response modelling suggested additive action on TJ integrity. Increasing SC and SML concentrations caused increased LDH leakage, but PFOS decreased LDH leakage at intermediate exposure concentrations. In the mixture PFOS appeared to protect from extensive SC- and SML-induced LDH leakage. Complex mixtures of surfactants in food may act additively on intestinal TJ integrity, which should be considered in risk assessment of emulsifier authorisation for use in food production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Mumps vaccine effectiveness and risk factors for disease in households during an outbreak in New York City.

    PubMed

    Livingston, Kara A; Rosen, Jennifer B; Zucker, Jane R; Zimmerman, Christopher M

    2014-01-09

    Mumps outbreaks have been reported among vaccinated populations, and declining mumps vaccine effectiveness (VE) has been suggested as one possible cause. During a large mumps outbreak in New York City, we assessed: (1) VE of measles-mumps-rubella vaccine (MMR) against mumps and (2) risk factors for acquiring mumps in households. Cases of mumps were investigated using standard methods. Additional information on disease and vaccination status of household contacts was collected. Case households completed follow-up phone interviews 78-198 days after initial investigation to ascertain additional cases. Mumps cases meeting the study case definition were included in the analysis. Risk factors for mumps were assessed, and VE was calculated using secondary household attack rates. Three hundred and eleven households with 2176 residents were included in the analysis. The median age of residents was 13 years (range <1-85), and 462 (21.2%) residents met the study mumps case definition. Among 7-17 year olds, 89.7% received one or more doses of MMR vaccine, with 76.7% receiving two doses. Young adults aged 10-14 years (OR=2.4, CI=1.3-4.7) and 15-19 years (OR=2.5, CI=1.3-5.0) were at highest risk of mumps. The overall 2-dose VE for secondary contacts aged five and older was 86.3% (CI 63.3-94.9). The two-dose effectiveness of MMR vaccine against mumps was 86.3%, consistent with other published mumps VE estimates. Many factors likely contributed to this outbreak. Suboptimal MMR coverage in the affected population combined with VE may not have conferred adequate immunity to prevent transmission and may have contributed to this outbreak. Achieving high MMR coverage remains the best available strategy for prevention of mumps outbreaks. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. [Assessment of the use of racemic ketamine and its S(+) isomer, associated or not with low doses of fentanyl, in balneotherapy for major burn patients].

    PubMed

    Cantinho, Fernando Antônio de Freitas; Silva, Antonio Carlos Pereira da

    2009-01-01

    The care of the wounds of major burn patients triggers severe painful stimuli. The objective of this study was to assess the safety and efficacy of different drug combinations in anesthesia for balneotherapy. After approval by the Ethics Commission, 200 procedures of balneotherapy in 87 major burn adult patients were evaluated. Midazolam was used in all cases. The vials of ketamine were numbered and, therefore, at the time of the use, one did not know whether racemic or S(+)ketamine was being used. Each morning it was decided by drawing lots whether fentanyl would be used or not in the procedures of that day. Patients were included in one of four groups: ISO/sf (S(+) isomer without fentanyl), ISO/cf (S(+) isomer with fentanyl), RAC/sf (racemic ketamine without fentanyl), and RAC/cf (racemic ketamine with fentanyl). The initial doses proposed were as follows: midazolam, 0.06 mg.kg-1; ketamine, 1.0 to 1.1 mg.kg-1; and fentanyl, 0.8 (1/4)g.kg1-1; additional doses were administered as needed. Only one patient recalled the pain of balneotherapy. In the group that received S(+)ketamine, the use of fentanyl did not bring additional advantages; however, when associated with racemic ketamine, fentanyl reduced the total dose and the number of ketamine boluses. The extension of body surface burned was the main determinant of the severity of post-procedure pain. Reduced pain severity was the main factor considered by patients when grading their satisfaction with the anesthesia. The four different drug combinations proved to be safe and guaranteed the absence of pain during balneotherapy. Characteristics not directly related to the anesthetics proved to be more important in the incidence of post-procedure pain, which was the main factor considered by major burn patient to define their satisfaction with the anesthesia used.

  12. Impact of chemical proportions on the acute neurotoxicity of a mixture of seven carbamates in preweanling and adult rats.

    PubMed

    Moser, Virginia C; Padilla, Stephanie; Simmons, Jane Ellen; Haber, Lynne T; Hertzberg, Richard C

    2012-09-01

    Statistical design and environmental relevance are important aspects of studies of chemical mixtures, such as pesticides. We used a dose-additivity model to test experimentally the default assumptions of dose additivity for two mixtures of seven N-methylcarbamates (carbaryl, carbofuran, formetanate, methomyl, methiocarb, oxamyl, and propoxur). The best-fitting models were selected for the single-chemical dose-response data and used to develop a combined prediction model, which was then compared with the experimental mixture data. We evaluated behavioral (motor activity) and cholinesterase (ChE)-inhibitory (brain, red blood cells) outcomes at the time of peak acute effects following oral gavage in adult and preweanling (17 days old) Long-Evans male rats. The mixtures varied only in their mixing ratios. In the relative potency mixture, proportions of each carbamate were set at equitoxic component doses. A California environmental mixture was based on the 2005 sales of each carbamate in California. In adult rats, the relative potency mixture showed dose additivity for red blood cell ChE and motor activity, and brain ChE inhibition showed a modest greater-than additive (synergistic) response, but only at a middle dose. In rat pups, the relative potency mixture was either dose-additive (brain ChE inhibition, motor activity) or slightly less-than additive (red blood cell ChE inhibition). On the other hand, at both ages, the environmental mixture showed greater-than additive responses on all three endpoints, with significant deviations from predicted at most to all doses tested. Thus, we observed different interactive properties for different mixing ratios of these chemicals. These approaches for studying pesticide mixtures can improve evaluations of potential toxicity under varying experimental conditions that may mimic human exposures.

  13. Treatment-related toxicities in tumor-bearing cats treated with temozolomide alone or in combination with doxorubicin: a pilot assessment.

    PubMed

    Gagnon, Jerome; Dervisis, Nikolaos G; Kitchell, Barbara E

    2012-08-01

    A retrospective study assessing treatment-related toxicities in tumor-bearing cats treated with temozolomide (TMZ) alone or in combination with doxorubicin was conducted. TMZ was administered orally once a day for 5 days every 3 weeks at a dose of 20 mg/cat. Tumor response was evaluated with standard World Health Organization criteria and toxicity was monitored using veterinary co-operative oncology group-common terminology criteria for adverse events (VCOG--CTCAE) criteria. Ten tumor-bearing cats with various types of malignancies were treated with TMZ-based chemotherapy. Eight cats were evaluable for response. Two cats achieved a complete response, one achieved stable disease and five achieved a partial response. Four grade III and one grade IV hematological toxicities, and one grade IV gastrointestinal toxicity were observed. Four cats were euthanased as a result of apparent toxicity. One cat was euthanased as a result of severe and prolonged myelosuppression with fever. Three were euthanased for grade III pleural and pericardial effusions. Effusion was seen in cats treated with higher cumulative dose of TMZ (P = 0.0046). Planned additional case accrual was discontinued because of unacceptable levels of toxicity despite evidence of efficacy in some of the cats. Additional investigation is needed to elucidate this unexpected apparent cumulative toxicity.

  14. Additive effect of harmane and muscimol for memory consolidation impairment in inhibitory avoidance task.

    PubMed

    Nasehi, Mohammad; Morteza-Zadeh, Parastoo; Khakpai, Fatemeh; Zarrindast, Mohammad-Reza

    2016-12-17

    In the current study, we examined the effect of bilateral intra-dorsal hippocampal (intra-CA1) microinjections of GABA A receptor agents on amnesia induced by a β-carboline alkaloid, harmane in mice. We used a single-trial step-down passive avoidance task to assess memory retention and then, open-field test to assess locomotor activity. The results indicated that post-training intra-CA1 injections of bicuculline - a GABA A receptor antagonist - had no significant effect, while muscimol (0.01 and 0.1μg/mouse) - a GABA A receptor agonist - impaired memory consolidation. Post-training intra-peritoneal (i.p.) infusion of harmane (3 and 5mg/kg) decreased memory consolidation. Furthermore, post-training intra-CA1 administration of sub-threshold dose of bicuculline (0.001μg/mouse) restored, whereas muscimol (0.001μg/mouse) potentiated impairment of memory consolidation induced by harmane. The isobologram analysis revealed that there is an additive effect between harmane and muscimol on impairment of memory consolidation. Moreover, all above doses of drugs did not alter locomotor activity. These findings suggest that GABA A receptors of the CA1 area, at least partly, play a role in modulating the effect of harmane on memory consolidation. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. Coplanar intensity-modulated radiotherapy class solution for patients with prostate cancer with bilateral hip prostheses with and without nodal involvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Young K., E-mail: Young.Lee@rmh.nhs.uk; McVey, Gerard P.; South, Chris P.

    2013-07-01

    Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beammore » angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm{sup 3}) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V{sub 50} {sub Gy} objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.« less

  16. An analysis of the equivalent dose calculation for the remainder tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zankl, M.; Drexler, G.

    1995-09-01

    In the 1990 Recommendations of the International Commission on Radiological Protection, the risk-weighted quantity {open_quotes}effective dose equivalent{close_quotes} was replaced by a similar quantity, {open_quotes}effective dose.{close_quotes} Among other alterations, the selection of the organs and tissues contributing to the risk-weighted quantity and their respective weighting factors were changed, including a modified definition of the so-called {open_quotes}remainder.{close_quotes} Close consideration of this latter definition shows that is causes certain ambiguities are unexpected effects which are dealt with in the following. For several geometries of external photon irradiation, the numerical differences of two possible methods of evaluating the remainder dose from the doses tomore » ten single organs, namely as arithmetic mean or as mass weighted average, are assessed. It is shown that deviation from these averaging procedures, as prescribed for these cases where a remainder organ receives a higher dose than an organ with a specified weighting factor, cause discontinuities in the energy dependence of the remainder dose and, consequently, also non-additivity of this quantity. These problems are discussed, and it is shown that, although the numerical consequences for the calculation of the effective dose are small, this unsatisfactory situation needs clarification. One approach might be to abolish some of the ICRP guidance relating to the appropriate tissue weighting factors for the remainder tissues and organs and to make other guidance more precise. 14 refs., 12 figs., 2 tabs.« less

  17. Estimation of chloroform inhalation dose by other routes based on the relationship of area under the blood concentration-time curve (AUC)-inhalation dose to chloroform distribution in the blood of rats.

    PubMed

    Take, Makoto; Takeuchi, Tetsuya; Haresaku, Mitsuru; Matsumoto, Michiharu; Nagano, Kasuke; Yamamoto, Seigo; Takamura-Enya, Takeji; Fukushima, Shoji

    2014-01-01

    The present study investigated the time-course changes of concentration of chloroform (CHCl3) in the blood during and after exposure of male rats to CHCl3 by inhalation. Increasing the dose of CHCl3 in the inhalation exposed groups caused a commensurate increase in the concentration of CHCl3 in the blood and the area under the blood concentration-time curve (AUC). There was good correlation (r = 0.988) between the inhalation dose and the AUC/kg body weight. Based on the AUC/kg body weight-inhalation dose curve and the AUC/kg body weight after oral administration, inhalation equivalent doses of orally administered CHCl3 were calculated. Calculation of inhalation equivalent doses allows the body burden due to CHCl3 by inhalation exposure and oral exposure to be directly compared. This type of comparison facilitates risk assessment in humans exposed to CHCl3 by different routes. Our results indicate that when calculating inhalation equivalent doses of CHCl3, it is critical to include the AUC from the exposure period in addition to the AUC after the end of the exposure period. Thus, studies which measure the concentration of volatile organic compounds in the blood during the inhalation exposure period are crucial. The data reported here makes an important contribution to the physiologically based pharmacokinetic (PBPK) database of CHCl3 in rodents.

  18. Application of the Scoping of Options and Analyzing Risk Model (SOAR) in the Modeling of Radionuclide Movement and Dose Calculation for a Hypothetical Deep Geological Repository for Nuclear Fuel Wastes

    NASA Astrophysics Data System (ADS)

    Lei, S.; Osborne, P.

    2016-12-01

    The Scoping of Options and Analyzing Risk (SOAR) model was developed by the U.S. Nuclear Regulatory Commission staff to assist in their evaluation of potential high-level radioactive waste disposal options. It is a 1-D contaminant transport code that contains a biosphere module to calculate mass fluxes and radiation dose to humans. As part of the Canadian Nuclear Safety Commission (CNSC)'s Coordinated Assessment Program to assist with the review of proposals for deep geological repositories (DGR's) for nuclear fuel wastes, CNSC conducted a research project to find out whether SOAR can be used by CNSC staff as an independent scoping tool to assist review of proponents' submissions related to safety assessment for DGRs. In the research, SOAR was applied to the post-closure safety assessment for a hypothetical DGR in sedimentary rock, as described in the 5th Case Study report by the Nuclear Waste Management Organization (NWMO) of Canada (2011). The report contains, among others, modeling of transport and releases of radionuclides at various locations within the geosphere and the radiation dose to humans over a period of one million years. One aspect covered was 1-D modeling of various scenarios and sensitivity cases with both deterministic and probabilistic approaches using SYVAC3-CC4, which stands for Systems Variability Analysis Code (generation 3, Canadian Concept generation 4), developed by Atomic Energy of Canada Limited (Kitson et al., 2000). Radionuclide fluxes and radiation dose to the humans calculated using SOAR were compared with that from NWMO's modeling. Overall, the results from the two models were similar, although SOAR gave lower mass fluxes and peak dose, mainly due to differences in modeling the waste package configurations. Sensitivity analyses indicate that both models are most sensitive to the diffusion coefficient of the geological media. The research leads to the conclusion that SOAR is a robust, user friendly, and flexible scoping tool that CNSC staff may use for safety assessments; however, some improvements may be needed, such as including dose contributions from other pathways in addition to drinking water and being more flexible for modeling different waste package configurations.

  19. Phase II study of cabozantinib in patients with progressive glioblastoma: subset analysis of patients naive to antiangiogenic therapy

    PubMed Central

    Drappatz, Jan; de Groot, John; Prados, Michael D; Reardon, David A; Schiff, David; Chamberlain, Marc; Mikkelsen, Tom; Desjardins, Annick; Holland, Jaymes; Ping, Jerry; Weitzman, Ron; Cloughesy, Timothy F

    2018-01-01

    Abstract Background Cabozantinib is a tyrosine kinase inhibitor with activity against vascular endothelial growth factor receptor 2 (VEGFR2) and MET that has demonstrated clinical activity in advanced solid tumors. This open-label, phase II trial evaluated cabozantinib in patients with recurrent or refractory glioblastoma (GBM). Methods Patients were initially enrolled at a starting dose of 140 mg/day, but the starting dose was amended to 100 mg/day because of toxicity. Treatment continued until disease progression or unacceptable toxicity. The primary endpoint was objective response rate assessed by an independent radiology facility using modified Response Assessment in Neuro-Oncology criteria. Additional endpoints included duration of response, 6-month and median progression-free survival, overall survival, and safety. Results Among 152 patients naive to prior antiangiogenic therapy, the objective response rate was 17.6% and 14.5% in the 140 mg/day and 100 mg/day groups, respectively, which did not meet the predefined statistical target for success. The proportions of patients alive and progression free at 6 months were 22.3% and 27.8%, respectively. Median progression-free survival was 3.7 months in both groups, and median overall survival was 7.7 months and 10.4 months, respectively. The incidence of grade 3/4 adverse events (AEs) was 79.4% and 84.7% in the 140 mg/day and 100 mg/day groups, respectively, and dose reductions due to AEs were experienced by 61.8% and 72.0%, respectively. Common grade 3/4 AEs included fatigue, diarrhea, and palmar-plantar erythrodysesthesia syndrome. Conclusions Cabozantinib showed evidence of clinical activity in patients with recurrent GBM naive to antiangiogenic therapy, although the predefined statistical target for success was not met. At the starting doses assessed, AEs were frequently managed with dose reductions. Clinical Trials Registration Number NCT00704288 (https://www.clinicaltrials.gov/ct2/show/NCT00704288) PMID:29016998

  20. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brady, S. L.; Yee, B. S.; Kaufman, R. A.

    Purpose: This study demonstrates a means of implementing an adaptive statistical iterative reconstruction (ASiR Trade-Mark-Sign ) technique for dose reduction in computed tomography (CT) while maintaining similar noise levels in the reconstructed image. The effects of image quality and noise texture were assessed at all implementation levels of ASiR Trade-Mark-Sign . Empirically derived dose reduction limits were established for ASiR Trade-Mark-Sign for imaging of the trunk for a pediatric oncology population ranging from 1 yr old through adolescence/adulthood. Methods: Image quality was assessed using metrics established by the American College of Radiology (ACR) CT accreditation program. Each image quality metricmore » was tested using the ACR CT phantom with 0%-100% ASiR Trade-Mark-Sign blended with filtered back projection (FBP) reconstructed images. Additionally, the noise power spectrum (NPS) was calculated for three common reconstruction filters of the trunk. The empirically derived limitations on ASiR Trade-Mark-Sign implementation for dose reduction were assessed using (1, 5, 10) yr old and adolescent/adult anthropomorphic phantoms. To assess dose reduction limits, the phantoms were scanned in increments of increased noise index (decrementing mA using automatic tube current modulation) balanced with ASiR Trade-Mark-Sign reconstruction to maintain noise equivalence of the 0% ASiR Trade-Mark-Sign image. Results: The ASiR Trade-Mark-Sign algorithm did not produce any unfavorable effects on image quality as assessed by ACR criteria. Conversely, low-contrast resolution was found to improve due to the reduction of noise in the reconstructed images. NPS calculations demonstrated that images with lower frequency noise had lower noise variance and coarser graininess at progressively higher percentages of ASiR Trade-Mark-Sign reconstruction; and in spite of the similar magnitudes of noise, the image reconstructed with 50% or more ASiR Trade-Mark-Sign presented a more smoothed appearance than the pre-ASiR Trade-Mark-Sign 100% FBP image. Finally, relative to non-ASiR Trade-Mark-Sign images with 100% of standard dose across the pediatric phantom age spectrum, similar noise levels were obtained in the images at a dose reduction of 48% with 40% ASIR Trade-Mark-Sign and a dose reduction of 82% with 100% ASIR Trade-Mark-Sign . Conclusions: The authors' work was conducted to identify the dose reduction limits of ASiR Trade-Mark-Sign for a pediatric oncology population using automatic tube current modulation. Improvements in noise levels from ASiR Trade-Mark-Sign reconstruction were adapted to provide lower radiation exposure (i.e., lower mA) instead of improved image quality. We have demonstrated for the image quality standards required at our institution, a maximum dose reduction of 82% can be achieved using 100% ASiR Trade-Mark-Sign ; however, to negate changes in the appearance of reconstructed images using ASiR Trade-Mark-Sign with a medium to low frequency noise preserving reconstruction filter (i.e., standard), 40% ASiR Trade-Mark-Sign was implemented in our clinic for 42%-48% dose reduction at all pediatric ages without a visually perceptible change in image quality or image noise.« less

  1. Cumulative Effects of In Utero Administration of Mixtures of Reproductive Toxicants that Disrupt Common Target Tissues via Diverse Mechanisms of Toxicity

    PubMed Central

    Rider, Cynthia V.; Furr, Johnathan R.; Wilson, Vickie S.; Gray, L. Earl

    2010-01-01

    Although risk assessments are typically conducted on a chemical-by-chemical basis, the 1996 Food Quality Protection Act required the US Environmental Protection Agency to consider cumulative risk of chemicals that act via a common mechanism of toxicity. To this end, we are conducting studies with mixtures of chemicals to elucidate mechanisms of joint action at the systemic level with the end goal of providing a framework for assessing the cumulative effects of reproductive toxicants. Previous mixture studies conducted with antiandrogenic chemicals are reviewed briefly and two new studies are described in detail. In all binary mixture studies, rats were dosed during pregnancy with chemicals, singly or in pairs at dosage levels equivalent to approximately one half of the ED50 for hypospadias or epididymal agenesis. The binary mixtures included: androgen receptor (AR) antagonists (vinclozolin plus procymidone), phthalate esters (DBP plus BBP and DEHP plus DBP), a phthalate ester plus an AR antagonist (DBP plus procymidone), a mixed mechanism androgen signaling disruptor (linuron) plus BBP, and two chemicals which disrupt epididymal differentiation through entirely different toxicity pathways: DBP (AR pathway) plus 2,3,7,8 TCDD (AhR pathway). We also conducted multi-component mixture studies combining several “antiandrogens” together. In the first study, seven chemicals (four pesticides and three phthalates) that elicit antiandrogenic effects at two different sites in the androgen signaling pathway (i.e. AR antagonist or inhibition of androgen synthesis) were combined. In the second study, three additional phthalates were added to make a ten chemical mixture. In both the binary mixture studies and the multi-component mixture studies, chemicals that targeted male reproductive tract development displayed cumulative effects that exceeded predictions based upon a response addition model and most often were in accordance with predictions based upon dose addition models. In summary, our results indicate that compounds that act by disparate mechanisms of toxicity to disrupt the dynamic interactions among the interconnected signaling pathways in differentiating tissues produce cumulative dose-additive effects, regardless of the mechanism or mode of action of the individual mixture component. PMID:20487044

  2. Cognitive Functioning After Radiotherapy or Chemoradiotherapy for Head-and-Neck Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gan, Hui K.; Bernstein, Lori J.; Brown, Jennifer

    Purpose: To perform a comprehensive cognitive function (CF) assessment in patients who were relapse free after curative intent radiotherapy (RT) or chemoradiotherapy for squamous cell carcinoma of the head and neck. Methods and Materials: Patients underwent neuropsychological tests to assess their objective CF; completed questionnaires to assess subjective CF, quality of life, and affect; and underwent blood tests to assess hematologic, biochemical, endocrine, and cytokine status. Retrospectively, the dosimetry of incidental radiation to the brain was determined for all patients, and the dose intensity of cisplatin was determined in those who had undergone chemoradiotherapy. Results: A total of 10 patientsmore » were enrolled (5 treated with radiotherapy only and 5 with radiotherapy and cisplatin). The mean time from the end of treatment was 20 months (range, 9-41). All patients were able to complete the assessment protocol. Of the 10 patients, 9 had impaired objective CF, with memory the most severely affected. The severity of memory impairment correlated significantly with the radiation dose to the temporal lobes, and impaired dexterity correlated significantly with the radiation dose to the cerebellum, suggesting that these deficits might be treatment related. Patients receiving cisplatin appeared to have poorer objective CF than patients receiving only RT, although this difference did not achieve statistical significance, likely owing to the small sample size. Consistent with the published data, objective CF did not correlate with subjective CF or quality of life. No association was found between objective CF and patients' affect, hematologic, biochemical, endocrine, and cytokine status. Conclusion: Neuropsychological testing is feasible in squamous cell carcinoma of the head-and-neck survivors. The findings were suggestive of treatment-related cognitive dysfunction. These results warrant additional investigation.« less

  3. Incidence of thromboembolism after transurethral resection of the prostate (TURP)--a study on TED stocking prophylaxis and literature review.

    PubMed

    Donat, R; Mancey-Jones, B

    2002-01-01

    To assess the incidence of clinically evident pulmonary emboli and deep vein thromboses in patients undergoing transurethral resection of the prostate (TURP) with the routine use of graduated elastic compression stockings (TED) in all patients and the addition of low-dose heparin in selected high-risk patients. A retrospective analysis of clinically evident thromboembolic complications within 4 weeks of operation in 883 patients operated in a single hospital during a 4-year period. Four patients (0.45%) developed pulmonary emboli (PE), of which two (0.23%) were fatal. There was one clinically evident deep vein thrombosis (DVT) in a high-risk patient (0.11%). None of the 14 high-risk patients receiving additional low-dose heparin required a blood transfusion. Clinical thromboembolic complications following TURP are rare. TURP patients have a low risk for DVT, but an intermediate risk for pulmonary emboli. Pulmonary emboli may occur without identifiable risk factors and despite TED stocking prophylaxis.

  4. Coffee and tea: perks for health and longevity?

    PubMed

    Bhatti, Salman K; O'Keefe, James H; Lavie, Carl J

    2013-11-01

    Tea and coffee, after water, are the most commonly consumed beverages in the world and are the top sources of caffeine and antioxidant polyphenols in the American diet. The purpose of this review is to assess the health effects of chronic tea and/or coffee consumption. Tea consumption, especially green tea, is associated with significantly reduced risks for stroke, diabetes and depression, and improved levels of glucose, cholesterol, abdominal obesity and blood pressure. Habitual coffee consumption in large epidemiological studies is associated with reduced mortality, both for all-cause and cardiovascular deaths. In addition, coffee intake is associated with risks of heart failure, stroke, diabetes mellitus and some cancers in an inverse dose-dependent fashion. Surprisingly, coffee is associated with neutral to reduced risks for both atrial and ventricular arrhythmias. However, caffeine at high doses can increase anxiety, insomnia, calcium loss and possibly the risk of fractures. Coffee and tea can generally be recommended as health-promoting additions to an adult diet. Adequate dietary calcium intake may be particularly important for tea and coffee drinkers.

  5. High but not low ECS stimulus intensity augments apomorphine-stimulated dopamine postsynaptic receptor functioning in rats.

    PubMed

    Andrade, Chittaranjan; Srinivasamurthy, Gurunath M; Vishwasenani, A; Prakash, G Sai; Srihari, B S; Chandra, J Suresh

    2002-06-01

    Clinical research shows that the antidepressant and cognitive adverse effects of electroconvulsive therapy are both dependent on the administered electrical stimulus intensity (dose); however, dose-dependent neurotransmitter system changes in the brain, which might underlie the therapeutic or adverse effects, remain to be demonstrated. We used a behavioral model to examine dose-related effects of electroconvulsive shock (ECS) on dopamine postsynaptic receptor functioning in the rat brain. In a factorially designed study, rats (n = 100) were treated with five once-daily ECSs at three levels (sham ECS, 30 mC ECS, and 120 mC ECS), and with drug at two levels (saline, and 1 mg/kg s.c. apomorphine). Motility was assessed in the small open field. Apomorphine-elicited, dopamine postsynaptic receptor-mediated hypermotility was significantly increased by 120 mC ECS but not by 30 mC ECS. An additional but unrelated finding was that, while the ECS seizure duration expectedly decreased across time, no dose-dependent effects were observed. ECS-induced dopamine postsynaptic receptor up-regulation may depend on the intensity of the administered electrical stimulus.

  6. Toxicity and Pharmacokinetic Profile for Single-Dose Injection of ABY-029: a Fluorescent Anti-EGFR Synthetic Affibody Molecule for Human Use.

    PubMed

    Samkoe, Kimberley S; Gunn, Jason R; Marra, Kayla; Hull, Sally M; Moodie, Karen L; Feldwisch, Joachim; Strong, Theresa V; Draney, Daniel R; Hoopes, P Jack; Roberts, David W; Paulsen, Keith; Pogue, Brian W

    2017-08-01

    ABY-029, a synthetic Affibody peptide, Z03115-Cys, labeled with a near-infrared fluorophore, IRDye® 800CW, targeting epidermal growth factor receptor (EGFR) has been produced under good manufacturing practices for a US Food and Drug Administration-approved first-in-use human study during surgical resection of glioma, as well as other tumors. Here, the pharmacology, phototoxicity, receptor activity, and biodistribution studies of ABY-029 were completed in rats, prior to the intended human use. Male and female Sprague Dawley rats were administered a single intravenous dose of varying concentrations (0, 245, 2449, and 24,490 μg/kg corresponding to 10×, 100×, and 1000× an equivalent human microdose level) of ABY-029 and observed for up to 14 days. Histopathological assessment of organs and tissues, clinical chemistry, and hematology were performed. In addition, pharmacokinetic clearance and biodistribution of ABY-029 were studied in subgroups of the animals. Phototoxicity and ABY-029 binding to human and rat EGFR were assessed in cell culture and on immobilized receptors, respectively. Histopathological assessment and hematological and clinical chemistry analysis demonstrated that single-dose ABY-029 produced no pathological evidence of toxicity at any dose level. No phototoxicity was observed in EGFR-positive and EGFR-negative glioma cell lines. Binding strength and pharmacokinetics of the anti-EGFR Affibody molecules were retained after labeling with the dye. Based on the successful safety profile of ABY-029, the 1000× human microdose 24.5 mg/kg was identified as the no observed adverse effect level following intravenous administration. Conserved binding strength and no observed light toxicity also demonstrated ABY-029 safety for human use.

  7. Credentialing of radiotherapy centres in Australasia for TROG 09.02 (Chisel), a Phase III clinical trial on stereotactic ablative body radiotherapy of early stage lung cancer.

    PubMed

    Kron, Tomas; Chesson, Brent; Hardcastle, Nicholas; Crain, Melissa; Clements, Natalie; Burns, Mark; Ball, David

    2018-05-01

    A randomised clinical trial comparing stereotactic ablative body radiotherapy (SABR) with conventional radiotherapy for early stage lung cancer has been conducted in Australia and New Zealand under the auspices of the TransTasman Radiation Oncology Group (NCT01014130). We report on the technical credentialing program as prerequisite for centres joining the trial. Participating centres were asked to develop treatment plans for two test cases to assess their ability to create plans according to protocol. Dose delivery in the presence of inhomogeneity and motion was assessed during a site visit using a phantom with moving inserts. Site visits for the trial were conducted in 16 Australian and 3 New Zealand radiotherapy facilities. The tests with low density inhomogeneities confirmed shortcomings of the AAA algorithm for dose calculation. Dose was assessed for a typical treatment delivery including at least one non-coplanar beam in a stationary and moving phantom. This end-to-end test confirmed that all participating centres were able to deliver stereotactic ablative body radiotherapy with the required accuracy while the planning study demonstrated that they were able to produce acceptable plans for both test cases. The credentialing process documented that participating centres were able to deliver dose as required in the trial protocol. It also gave an opportunity to provide education about the trial and discuss technical issues such as four-dimensional CT, small field dosimetry and patient immobilisation with staff in participating centres. Advances in knowledge: Credentialing is an important quality assurance tool for radiotherapy trials using advanced technology. In addition to confirming technical competence, it provides an opportunity for education and discussion about the trial.

  8. PUNISHING AND CARDIOVASCULAR EFFECTS OF INTRAVENOUS HISTAMINE IN RATS: PHARMACOLOGICAL SELECTIVITY

    PubMed Central

    Podlesnik, Christopher A.; Jimenez-Gomez, Corina

    2014-01-01

    Although drugs may serve as reinforcers or punishers of operant behavior, the punishing function has received much less experimental attention than the reinforcing function. A sensitive method for studying drug-induced punishment is to assess choice for a punished response over an unpunished response. In these experiments, rats chose between pressing one lever and receiving a sucrose pellet or pressing another lever and receiving a sucrose pellet plus an intravenous injection of histamine. When sucrose was delivered equally frequently for either the punished or the unpunished response, rats selected the unpunished lever consistently, but decreases in the punished response did not differ as a function of intravenous histamine dose (0.1–1 mg/kg/inj). Changing the procedure so that sucrose was delivered on the unpunished lever with p = .5 increased the rats’ responding on the punished lever with saline injections. In addition, the same range of histamine doses produced a much larger range of responses on the punished lever that was dose dependent. Using these procedures to assess the receptors mediating histamine’s effects, the histamine H1-receptor antagonists, pyrilamine and ketotifen, antagonized the punishing effect of histamine, but the histamine H2-receptor antagonist ranitidine did not. However, ranitidine pretreatments reduced histamine-induced heart-rate increases to a greater extent than did the histamine H1-receptor antagonists when administered at the same doses examined under conditions of histamine punishment. Overall, the present findings extend the general hypothesis that activation of histamine H1-receptors mediates the punishing effects of histamine. They also introduce methods for rapidly assessing pharmacological mechanisms underlying drug-induced punishment. PMID:23982898

  9. Dose-Response Effects of Aerobic Exercise on Quality of Life in Postmenopausal Women: Results from the Breast Cancer and Exercise Trial in Alberta (BETA).

    PubMed

    Courneya, Kerry S; McNeil, Jessica; O'Reilly, Rachel; Morielli, Andria R; Friedenreich, Christine M

    2017-06-01

    Exercise generally improves quality of life (QoL) and psychosocial functioning in adult populations but few randomized trials have examined dose-response effects. The purpose of the present study was to report the QoL and psychosocial outcomes from the Breast Cancer and Exercise Trial in Alberta (BETA). Healthy but inactive postmenopausal women at risk for breast cancer were randomized to a year-long aerobic exercise intervention consisting of either 150 min/week (moderate volume group, n = 200) or 300 min/week (high volume group, n = 200). QoL was assessed at baseline and 1 year using the short form-36 health survey. Sleep quality, depression, anxiety, stress, self-esteem, and happiness were also assessed. Participant preference for group assignment (i.e., exercise volume) was assessed at baseline and tested as a moderator. There were no statistically significant dose-response effects of aerobic exercise on any QoL, sleep quality, or psychosocial outcome. Participant preference for group assignment did not moderate any QoL, sleep quality, or psychosocial responses. Marital status was a significant moderator (p for interaction = 0.01) and obesity showed a trend towards being a moderator (p for interaction = 0.08) of the dose-response effects of aerobic exercise on global sleep quality such that unmarried and obese women improved sleep quality with the higher volume of aerobic exercise. A higher volume of aerobic exercise, approximately double the minimum public health guideline, did not provide additional QoL or psychosocial benefits compared to the minimum public health guideline in inactive postmenopausal women, even for women who preferred the higher volume of exercise at baseline. Trial Registration clinicaltrials.gov identifier: NCT1435005.

  10. Confirmatory field study for the evaluation of ciclosporin at a target dose of 7.0 mg/kg (3.2 mg/lb) in the control of feline hypersensitivity dermatitis.

    PubMed

    Roberts, Elizabeth S; Speranza, Cindy; Friberg, Cecilia; Griffin, Craig; Steffan, Jean; Roycroft, Linda; King, Stephen

    2016-11-01

    Objectives This study was designed to confirm the efficacy and tolerability of a daily dose of 7.0 mg/kg (3.2 mg/lb) ciclosporin (CsA) in the treatment of feline hypersensitivity dermatitis (HD), as this includes some of the most frequently suspected skin diseases in cats and recent publications have reported the successful use of CsA in the treatment of feline HD. Methods In total, 217 cats with feline HD were treated daily for 42 days with a target dose of 7 mg/kg CsA (n = 144) or a placebo control (n = 73) administered either in the food or directly in the mouth following feeding. Clinical and dermatological evaluations were conducted on days 0, 21 and 42, or study exit. Safety was evaluated through physical examinations, clinical pathology and the monitoring of adverse events (AEs). Results Administration of CsA at 7.0 mg/kg produced a significant improvement in the total lesion score ( P <0.0001). The average reduction from visit 1 to visit 3 was 65.1% in the CsA group (9.2% for the placebo). In addition, owners assessed 78.3% of the cases in the CsA group as a success. Statistically significant recoveries were also seen in extent of lesions, investigator assessment of overall improvement, and mean improvement in both the investigators' and owners' assessment of pruritus. Mild gastrointestinal disorders were the most common AEs but did not require cessation of therapy. Conclusions and relevance Results confirm that 7.0 mg/kg CsA dosed daily in food or orally for up to 6 weeks is effective and well tolerated by cats with feline HD.

  11. Monte Carlo study of out-of-field exposure in carbon-ion radiotherapy with a passive beam: Organ doses in prostate cancer treatment.

    PubMed

    Yonai, Shunsuke; Matsufuji, Naruhiro; Akahane, Keiichi

    2018-04-23

    The aim of this work was to estimate typical dose equivalents to out-of-field organs during carbon-ion radiotherapy (CIRT) with a passive beam for prostate cancer treatment. Additionally, sensitivity analyses of organ doses for various beam parameters and phantom sizes were performed. Because the CIRT out-of-field dose depends on the beam parameters, the typical values of those parameters were determined from statistical data on the target properties of patients who received CIRT at the Heavy-Ion Medical Accelerator in Chiba (HIMAC). Using these typical beam-parameter values, out-of-field organ dose equivalents during CIRT for typical prostate treatment were estimated by Monte Carlo simulations using the Particle and Heavy-Ion Transport Code System (PHITS) and the ICRP reference phantom. The results showed that the dose decreased with distance from the target, ranging from 116 mSv in the testes to 7 mSv in the brain. The organ dose equivalents per treatment dose were lower than those either in 6-MV intensity-modulated radiotherapy or in brachytherapy with an Ir-192 source for organs within 40 cm of the target. Sensitivity analyses established that the differences from typical values were within ∼30% for all organs, except the sigmoid colon. The typical out-of-field organ dose equivalents during passive-beam CIRT were shown. The low sensitivity of the dose equivalent in organs farther than 20 cm from the target indicated that individual dose assessments required for retrospective epidemiological studies may be limited to organs around the target in cases of passive-beam CIRT for prostate cancer. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Long-term Pulmonary Responses to Quadweekly Intermittent Intratracheal Spray Instillations of Magnetite (Fe3O4) Nanoparticles for 52 Weeks in Fischer 344 Rats.

    PubMed

    Tada, Yukie; Yano, Norio; Takahashi, Hiroshi; Yuzawa, Katsuhiro; Ando, Hiroshi; Kubo, Yoshikazu; Nagasawa, Akemichi; Inomata, Akiko; Ogata, Akio; Nakae, Dai

    2013-12-01

    Information about potential risks of iron nanomaterials is still limited, while a wide variety of applications are expected. We recently reported acute phase responses of male and female Fischer 344 rats after a single intratracheal spray instillation of Fe3O4 nanoparticles (magnetite), clearly showing dose-dependent pulmonary inflammatory changes (Tada et al., J Toxicol Pathol 25, 233-239, 2012). The present study assessed long-term responses of male and female Fischer 344 rats to multiple administrations of magnetite. Ten-week-old male and female Fischer 344 rats (n=20/group) were exposed to a total of 13 quadweekly intermittent intratracheal spray instillations of magnetite during the experimental period of 52 weeks, at doses of 0, 0.2 (low), 1.0 (medium) and 5.0 (high-dose) mg/kg body weight per administration. Absolute and relative lung weights of the high-dose group were significantly higher than those of the control group. Macroscopically, slight enlargement and scattered black patches were recognized in the lungs and the lung-associated lymph nodes of the high-dose group. Histopathologically, infiltration of macrophages phagocytosing magnetite (all dose groups) and of chronic inflammatory cells (medium- and high-dose males and high-dose females), alveolar bronchiolization and granuloma (high-dose group) were observed. In addition, alveolar hyperplasias were observed in some rats of the high-dose group, and cytoplasmic overexpression of β-catenin protein was immunohistochemically found in such lesions. The present results clearly show that instilled magnetite causes chronic inflammatory responses in the lung. These responses occur in a dose-dependent manner without apparent differences among sexes.

  13. Cosmic radiation exposure of biological test systems during the EXPOSE-E mission.

    PubMed

    Berger, Thomas; Hajek, Michael; Bilski, Pawel; Körner, Christine; Vanhavere, Filip; Reitz, Günther

    2012-05-01

    In the frame of the EXPOSE-E mission on the Columbus external payload facility EuTEF on board the International Space Station, passive thermoluminescence dosimeters were applied to measure the radiation exposure of biological samples. The detectors were located either as stacks next to biological specimens to determine the depth dose distribution or beneath the sample carriers to determine the dose levels for maximum shielding. The maximum mission dose measured in the upper layer of the depth dose part of the experiment amounted to 238±10 mGy, which relates to an average dose rate of 408±16 μGy/d. In these stacks of about 8 mm height, the dose decreased by 5-12% with depth. The maximum dose measured beneath the sample carriers was 215±16 mGy, which amounts to an average dose rate of 368±27 μGy/d. These values are close to those assessed for the interior of the Columbus module and demonstrate the high shielding of the biological experiments within the EXPOSE-E facility. Besides the shielding by the EXPOSE-E hardware itself, additional shielding was experienced by the external structures adjacent to EXPOSE-E, such as EuTEF and Columbus. This led to a dose gradient over the entire exposure area, from 215±16 mGy for the lowest to 121±6 mGy for maximum shielding. Hence, the doses perceived by the biological samples inside EXPOSE-E varied by 70% (from lowest to highest dose). As a consequence of the high shielding, the biological samples were predominantly exposed to galactic cosmic heavy ions, while electrons and a significant fraction of protons of the radiation belts and solar wind did not reach the samples.

  14. Chromosome translocations in T. scripta: the dose-rate effect and in vivo lymphocyte radiation response.

    PubMed

    Ulsh, B A; Whicker, F W; Congdon, J D; Bedford, J S; Hinton, T G

    2001-01-01

    Using a whole-chromosome FISH painting probe we previously developed for chromosome 1 of the yellow-bellied slider turtle (Trachemys scripta), we investigated the dose-rate effect for radiation-induced symmetrical translocations in T. scripta fibroblasts and lymphocytes. The dose rate below which no reduction in effect per unit dose is observed with further dose protraction was approximately 23 cGy h(-1). We estimated the whole-genome spontaneous background level of complete, apparently simple symmetrical translocations in T. scripta lymphocytes to be approximately 1.20 x 10(-3)/cell projected from aberrations occurring in chromosome 1. Similar spontaneous background levels reported for humans are some 6- to 25-fold higher, ranging from about 6 x 10(-3) to 3.4 x 10(-2) per cell. This relatively low background level for turtles would be a significant advantage for resolution of effects at low doses and dose rates. We also chronically irradiated turtles over a range of doses from 0-8 Gy delivered at approximately 5.5 cGy h(-1) and constructed a lymphocyte dose-response curve for complete, apparently simple symmetrical translocations suitable for use with animals chronically exposed to radiation in contaminated environments. The best-fitting calibration curve (not constrained through the zero dose estimate) was of the form Y(as) = c + aD + bD(2), where Y(as) was the number of apparently simple symmetrical translocations per cell, D was the dose (Gy), a = (0.0058 +/- 0.0009), b = (-0.00033 +/- 0.00011), and c = (0.0015 +/- 0.0013). With additional whole-chromosome probes to improve sensitivity, environmental biodosimetry using stable chromosome translocations could provide a practical and genetically relevant measurement end point for ecological risk assessments and biomonitoring programs.

  15. SU-E-T-308: Dosimetric Comparison of SBRT VMAT Treatment Plans Generated for 6 MV, 6 MV FFF, and 10 MV FFF Photon Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, D; Wang, B; Dunlap, N

    2015-06-15

    Purpose: To assess differences in treatment plan quality between VMAT stereotactic body plans generated using the 6 MV, 6 MV FFF, and 10 MV FFF modalities available in our clinic. Plans for lung, spine, and other sites were compared to see if there is any advantage of one modality over the other. Methods: Treatment plans done for actual SBRT patients were selected. Groups of ten lung plans, five spine plans, and five plans from other sites were selected. New treatment plans were generated for each plan using the Varian Eclipse AAA algorithm. The constraints were kept the same as usedmore » in the actual plans, but the same version of software was used to generate plans for the three modalities. In addition, because there are natural variations in plans re-done with the same dose constraints, one of the lung plans was repeated ten times to assess those differences. Volumes of the 100%, 90%, 50%, 20% and 10% isodose surfaces were compared. Maximum dose two centimeters from the PTV were compared, as well as the volume of the 105% isodose surface outside of the PTV. In addition, the 20 Gray lung volume was compared for the lung plans. The values of these parameters were divided by the values for the 6 MV plans for comparison. Average and standard deviations were obtained for quantities in each group. The Student t test was done to determine if differences were seen at the 95% confidence level. Results: Comparison of the treatment plans showed no significant differences when assessing these volumes and doses. There were not any trends seen when comparing modalities as a function of PTV volume either. Conclusion: There is no obvious dosimetric advantage in selection of one modality over another for these types of SBRT plans.« less

  16. Feasibility and acceptability of oral cholera vaccine mass vaccination campaign in response to an outbreak and floods in Malawi.

    PubMed

    Msyamboza, Kelias Phiri; M'bang'ombe, Maurice; Hausi, Hannah; Chijuwa, Alexander; Nkukumila, Veronica; Kubwalo, Hudson Wenji; Desai, Sachin; Pezzoli, Lorenzo; Legros, Dominique

    2016-01-01

    Despite some improvement in provision of safe drinking water, proper sanitation and hygiene promotion, cholera still remains a major public health problem in Malawi with outbreaks occurring almost every year since 1998. In response to 2014/2015 cholera outbreak, ministry of health and partners made a decision to assess the feasibility and acceptability of conducting a mass oral cholera vaccine (OCV) as an additional public health measure. This paper highlights the burden of the 2014/15 cholera outbreak, successes and challenges of OCV campaign conducted in March and April 2015. This was a documentation of the first OCV campaign conducted in Malawi. The campaign targeted over 160,000 people aged one year or more living in 19 camps of people internally displaced by floods and their surrounding communities in Nsanje district. It was a reactive campaign as additional measure to improved water, sanitation and hygiene in response to the laboratory confirmed cholera outbreak. During the first round of the OCV campaign conducted from 30 March to 4 April 2015, a total of 156,592 (97.6%) people out of 160,482 target population received OCV. During the second round (20 to 25 April 2015), a total of 137,629 (85.8%) people received OCV. Of these, 108,247 (67.6%) people received their second dose while 29,382 (18.3%) were their first dose. Of the 134,836 people with known gender and sex who received 1 or 2 doses, 54.4% were females and over half (55.4%) were children under the age of 15 years. Among 108,237 people who received 2 doses (fully immunized), 54.4% were females and 51.9% were children under 15 years of age. No severe adverse event following immunization was reported. The main reason for non-vaccination or failure to take the 2 doses was absence during the period of the campaign. This documentation has demonstrated that it was feasible, acceptable by the community to conduct a large-scale mass OCV campaign in Malawi within five weeks. Of 320,000 OCV doses received, Malawi managed to administer at least 294,221 (91.9%) of the doses. OCV could therefore be considered to be introduced as additional measure in cholera hot spot areas in Malawi.

  17. Feasibility and acceptability of oral cholera vaccine mass vaccination campaign in response to an outbreak and floods in Malawi

    PubMed Central

    Msyamboza, Kelias Phiri; M'bang'ombe, Maurice; Hausi, Hannah; Chijuwa, Alexander; Nkukumila, Veronica; Kubwalo, Hudson Wenji; Desai, Sachin; Pezzoli, Lorenzo; Legros, Dominique

    2016-01-01

    Introduction Despite some improvement in provision of safe drinking water, proper sanitation and hygiene promotion, cholera still remains a major public health problem in Malawi with outbreaks occurring almost every year since 1998. In response to 2014/2015 cholera outbreak, ministry of health and partners made a decision to assess the feasibility and acceptability of conducting a mass oral cholera vaccine (OCV) as an additional public health measure. This paper highlights the burden of the 2014/15 cholera outbreak, successes and challenges of OCV campaign conducted in March and April 2015. Methods This was a documentation of the first OCV campaign conducted in Malawi. The campaign targeted over 160,000 people aged one year or more living in 19 camps of people internally displaced by floods and their surrounding communities in Nsanje district. It was a reactive campaign as additional measure to improved water, sanitation and hygiene in response to the laboratory confirmed cholera outbreak. Results During the first round of the OCV campaign conducted from 30 March to 4 April 2015, a total of 156,592 (97.6%) people out of 160,482 target population received OCV. During the second round (20 to 25 April 2015), a total of 137,629 (85.8%) people received OCV. Of these, 108,247 (67.6%) people received their second dose while 29,382 (18.3%) were their first dose. Of the 134,836 people with known gender and sex who received 1 or 2 doses, 54.4% were females and over half (55.4%) were children under the age of 15 years. Among 108,237 people who received 2 doses (fully immunized), 54.4% were females and 51.9% were children under 15 years of age. No severe adverse event following immunization was reported. The main reason for non-vaccination or failure to take the 2 doses was absence during the period of the campaign. Conclusion This documentation has demonstrated that it was feasible, acceptable by the community to conduct a large-scale mass OCV campaign in Malawi within five weeks. Of 320,000 OCV doses received, Malawi managed to administer at least 294,221 (91.9%) of the doses. OCV could therefore be considered to be introduced as additional measure in cholera hot spot areas in Malawi. PMID:27347292

  18. Emergency Department Management of Patients Internally Contaminated with Radioactive Material

    PubMed Central

    Kazzi, Ziad; Buzzell, Jennifer; Bertelli, Luiz; Christensen, Doran

    2017-01-01

    SUMMARY Internal contamination with radioactive material can expose patients to radiation leading to short- and long-term clinical consequences. After the patient’s emergency conditions are addressed and the skin is decontaminated, the treating physicians assess the amount of radioactive material that has been internalized. This evaluation allows the estimation of the radiation dose that is delivered the specific radionuclide inside the body and supports the need for additional therapies and monitoring. These complex assessments warrant the reliance on a multidisciplinary approach that incorporates local, regional, and national experts in radiation medicine and emergencies. PMID:25455668

  19. Transcriptomic Dose-Response Analysis for Mode of Action ...

    EPA Pesticide Factsheets

    Microarray and RNA-seq technologies can play an important role in assessing the health risks associated with environmental exposures. The utility of gene expression data to predict hazard has been well documented. Early toxicogenomics studies used relatively high, single doses with minimal replication. Thus, they were not useful in understanding health risks at environmentally-relevant doses. Until the past decade, application of toxicogenomics in dose response assessment and determination of chemical mode of action has been limited. New transcriptomic biomarkers have evolved to detect chemical hazards in multiple tissues together with pathway methods to study biological effects across the full dose response range and critical time course. Comprehensive low dose datasets are now available and with the use of transcriptomic benchmark dose estimation techniques within a mode of action framework, the ability to incorporate informative genomic data into human health risk assessment has substantially improved. The key advantage to applying transcriptomic technology to risk assessment is both the sensitivity and comprehensive examination of direct and indirect molecular changes that lead to adverse outcomes. Book Chapter with topic on future application of toxicogenomics technologies for MoA and risk assessment

  20. Impact of High-Fidelity Simulation and Pharmacist-Specific Didactic Lectures in Addition to ACLS Provider Certification on Pharmacy Resident ACLS Performance.

    PubMed

    Bartel, Billie J

    2014-08-01

    This pilot study explored the use of multidisciplinary high-fidelity simulation and additional pharmacist-focused training methods in training postgraduate year 1 (PGY1) pharmacy residents to provide Advanced Cardiovascular Life Support (ACLS) care. Pharmacy resident confidence and comfort level were assessed after completing these training requirements. The ACLS training requirements for pharmacy residents were revised to include didactic instruction on ACLS pharmacology and rhythm recognition and participation in multidisciplinary high-fidelity simulation ACLS experiences in addition to ACLS provider certification. Surveys were administered to participating residents to assess the impact of this additional education on resident confidence and comfort level in cardiopulmonary arrest situations. The new ACLS didactic and simulation training requirements resulted in increased resident confidence and comfort level in all assessed functions. Residents felt more confident in all areas except providing recommendations for dosing and administration of medications and rhythm recognition after completing the simulation scenarios than with ACLS certification training and the didactic components alone. All residents felt the addition of lectures and simulation experiences better prepared them to function as a pharmacist in the ACLS team. Additional ACLS training requirements for pharmacy residents increased overall awareness of pharmacist roles and responsibilities and greatly improved resident confidence and comfort level in performing most essential pharmacist functions during ACLS situations. © The Author(s) 2013.

  1. The Swedish radiological environmental protection regulations applied in a review of a license application for a geological repository for spent nuclear fuel.

    PubMed

    Andersson, Pål; Stark, Karolina; Xu, Shulan; Nordén, Maria; Dverstorp, Björn

    2017-11-01

    For the first time, a system for specific consideration of radiological environmental protection has been applied in a major license application in Sweden. In 2011 the Swedish Nuclear Fuel & Waste Management Co. (SKB) submitted a license application for construction of a geological repository for spent nuclear fuel at the Forsmark site. The license application is supported by a post-closure safety assessment, which in accordance with regulatory requirements includes an assessment of environmental consequences. SKB's environmental risk assessment uses the freely available ERICA Tool. Environmental media activity concentrations needed as input to the tool are calculated by means of complex biosphere modelling based on site-specific information gathered from site investigations, as well as from supporting modelling studies and projections of future biosphere conditions in response to climate change and land rise due to glacial rebound. SKB's application is currently being reviewed by the Swedish Radiation Safety Authority (SSM). In addition to a traditional document review with an aim to determine whether SKB's models are relevant, correctly implemented and adequately parametrized, SSM has performed independent modelling in order to gain confidence in the robustness of SKB's assessment. Thus, SSM has used alternative stylized reference biosphere models to calculate environmental activity concentrations for use in subsequent exposure calculations. Secondly, an alternative dose model (RESRAD-BIOTA) is used to calculate doses to biota that are compared with SKB's calculations with the ERICA tool. SSM's experience from this review is that existing tools for environmental dose assessment are possible to use in order to show compliance with Swedish legislation. However, care is needed when site representative species are assessed with the aim to contrast them to generic reference organism. The alternative modelling of environmental concentrations resulted in much lower concentrations compared to SKB's results. However, SSM judges that SKB's in this part conservative approach is relevant for a screening assessment. SSM also concludes that there are big differences in dose rates calculated to different organisms depending on which tool that is used, although not systematically higher for either of them. Finally, independent regulatory modelling has proven valuable for SSM's review in gaining understanding and confidence in SKB's assessment presented in the license application. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Ketamine as an Adjunct to Opioids for Acute Pain in the Emergency Department: A Randomized Controlled Trial.

    PubMed

    Bowers, Karen J; McAllister, Kelly B; Ray, Meredith; Heitz, Corey

    2017-06-01

    This study had five objectives: 1) to measure and compare total opioid use and number of opioid doses in patients treated with opioids versus ketamine in conjunction with opioids; 2) to measure pain scores up to 2 hours after presentation in the ED patient with pain, comparing standard opioid pain control to ketamine in conjunction with opioids; 3) to compare patient satisfaction with pain control using opioids alone versus ketamine in conjunction with opioids; 4) to monitor and compare side effects in patients treated with opioids versus ketamine in conjunction with opioids; and 5) to identify effect variation between different subgroups of patients, with the purpose of focusing future research. We hypothesized that low-dose ketamine, compared to placebo, as an adjunctive treatment to opioids would result in better pain control over 2 hours and greater patient satisfaction with pain control; further, this protocol will result in a lower opioid dosage over 2 hours. This was a randomized, double-blinded, placebo-controlled trial at a single academic emergency department evaluating the use of ketamine versus placebo in conjunction with opioids for moderate to severe pain. Subjects with a continued high level of pain after an initial dose of opioid analgesia were randomized to receive either 0.1 mg/kg ketamine or placebo prior to protocol-based dosing of additional opioid analgesia, if required. Over 120 minutes, subjects were assessed for pain level (0-10), satisfaction with pain control (0-4), side effects, sedation level, and need for additional pain medication. Total opioid dose, including the initial dose, was compared between groups. Sixty-three subjects were randomized to the placebo group and 53 to the ketamine group. No significant differences were found in demographics between the groups. Patients receiving ketamine reported lower pain scores over 120 minutes than patients receiving placebo (p = 0.015). Total opioid dose was lower in the ketamine group (mean ± SD = 9.95 ± 4.83 mg) compared to placebo (mean ± SD = 12.81 ± 6.81 mg; p = 0.02). Satisfaction did not differ between groups. Fewer patients in the ketamine group required additional opioid doses. More patients reported light-headedness and dizziness in the ketamine group. Ketamine, as an adjunct to opioid therapy, was more effective at reducing pain over 120 minutes and resulted in a lower total opioid dose as well as fewer repeat doses of analgesia. More side effects were reported in the ketamine group (51% vs. 19%), but the side effect profile appears tolerable. © 2017 by the Society for Academic Emergency Medicine.

  3. The OPTIMIST study: optimisation of cost effectiveness through individualised FSH stimulation dosages for IVF treatment. A randomised controlled trial.

    PubMed

    van Tilborg, Theodora C; Eijkemans, Marinus J C; Laven, Joop S E; Koks, Carolien A M; de Bruin, Jan Peter; Scheffer, Gabrielle J; van Golde, Ron J T; Fleischer, Kathrin; Hoek, Annemieke; Nap, Annemiek W; Kuchenbecker, Walter K H; Manger, Petra A; Brinkhuis, Egbert A; van Heusden, Arne M; Sluijmer, Alexander V; Verhoeff, Arie; van Hooff, Marcel H A; Friederich, Jaap; Smeenk, Jesper M J; Kwee, Janet; Verhoeve, Harold R; Lambalk, Cornelis B; Helmerhorst, Frans M; van der Veen, Fulco; Mol, Ben Willem J; Torrance, Helen L; Broekmans, Frank J M

    2012-09-18

    Costs of in vitro fertilisation (IVF) are high, which is partly due to the use of follicle stimulating hormone (FSH). FSH is usually administered in a standard dose. However, due to differences in ovarian reserve between women, ovarian response also differs with potential negative consequences on pregnancy rates. A Markov decision-analytic model showed that FSH dose individualisation according to ovarian reserve is likely to be cost-effective in women who are eligible for IVF. However, this has never been confirmed in a large randomised controlled trial (RCT). The aim of the present study is to assess whether an individualised FSH dose regime based on an ovarian reserve test (ORT) is more cost-effective than a standard dose regime. Multicentre RCT in subfertile women indicated for a first IVF or intracytoplasmic sperm injection cycle, who are aged < 44 years, have a regular menstrual cycle and no major abnormalities at transvaginal sonography. Women with polycystic ovary syndrome, endocrine or metabolic abnormalities and women undergoing IVF with oocyte donation, will not be included. Ovarian reserve will be assessed by measuring the antral follicle count. Women with a predicted poor response or hyperresponse will be randomised for a standard versus an individualised FSH regime (150 IU/day, 225-450 IU/day and 100 IU/day, respectively). Participants will undergo a maximum of three stimulation cycles during maximally 18 months. The primary study outcome is the cumulative ongoing pregnancy rate resulting in live birth achieved within 18 months after randomisation. Secondary outcomes are parameters for ovarian response, multiple pregnancies, number of cycles needed per live birth, total IU of FSH per stimulation cycle, and costs. All data will be analysed according to the intention-to-treat principle. Cost-effectiveness analysis will be performed to assess whether the health and associated economic benefits of individualised treatment of subfertile women outweigh the additional costs of an ORT. The results of this study will be integrated into a decision model that compares cost-effectiveness of the three dose-adjustment strategies to a standard dose strategy. The study outcomes will provide scientific foundation for national and international guidelines. NTR2657.

  4. Impact of high- versus low-dose neuromuscular blocking agent administration on unplanned 30-day readmission rates in retroperitoneal laparoscopic surgery.

    PubMed

    Boon, Martijn; Martini, Chris; Yang, H Keri; Sen, Shuvayu S; Bevers, Rob; Warlé, Michiel; Aarts, Leon; Niesters, Marieke; Dahan, Albert

    2018-01-01

    Recent data shows that a neuromuscular block (NMB) induced by administration of high doses of rocuronium improves surgical conditions in certain procedures. However, there are limited data on the effect such practices on postoperative outcomes. We performed a retrospective analysis to compare unplanned 30-day readmissions in patients that received high-dose versus low-dose rocuronium administration during general anesthesia for laparoscopic retroperitoneal surgery. This retrospective cohort study was performed in the Netherlands in an academic hospital where routine high-dose rocuronium NMB has been practiced since July 2015. Charts of patients receiving anesthesia between January 2014 and December 2016 were searched for surgical cases receiving high-dose rocuronium and matched with respect to procedure, age, sex and ASA classification to patients receiving low-dose rocuronium. The primary post-operative outcome was unplanned 30-day readmission rate. There were 130 patients in each cohort. Patients in the high- and low-dose rocuronium cohorts received 217 ± 49 versus 37 ± 5 mg rocuronium, respectively. In the high-dose rocuronium group neuromuscular activity was consistently monitored; matched patients were unreliably monitored. All patients receiving high-dose rocuronium were reversed with sugammadex, while just 33% of matched patients were reversed with sugammadex and 20% with neostigmine; the remaining patients were not reversed. Unplanned 30-day readmission rate was significantly lower in the high-dose compared to the low-dose rocuronium cohort (3.8% vs. 12.7%; p = 0.03; odds ratio = 0.33, 95% C.I. 0.12-0.95). This small retrospective study demonstrates a lower incidence of unplanned readmissions within 30-days following laparoscopic retroperitoneal surgery with high-dose relaxant anesthesia and sugammadex reversal in comparison to low-dose relaxant anesthesia. Further prospective studies are needed in larger samples to corroborate our findings and additionally assess the pharmacoeconomics of high-dose relaxant anesthesia taking into account the benefits (reduced readmissions) and harm (cost of relaxants and reversal agents) of such practice.

  5. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J., E-mail: edwardc@schoolph.uma

    This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report'smore » Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.« less

  6. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses to the soft tissues for females are larger by 20% than the doses for males, because of the differences in the whole-body mass between males and females.

  7. Surface radiation dose comparison of a dedicated extremity cone beam computed tomography (CBCT) device and a multidetector computed tomography (MDCT) machine in pediatric ankle and wrist phantoms

    PubMed Central

    Nagy, Eszter; Apfaltrer, Georg; Riccabona, Michael; Singer, Georg; Stücklschweiger, Georg; Guss, Helmuth; Sorantin, Erich

    2017-01-01

    Objectives To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. Methods Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. Results Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). Conclusions Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications. PMID:28570626

  8. Pancreatic enzymes prepared in bicarbonate solution for administration through enteral feeding tubes.

    PubMed

    Boullata, Angela M; Boullata, Joseph I

    2015-07-15

    The dissolution and physicochemical effects of preparing delayed-release pancrelipase in a sodium bicarbonate solution before administration via an enteral feeding tube were studied. Several doses of four delayed-release pancrelipase products (Creon, Pancreaze, Ultresa, Zenpep) were studied. The intact contents of pancrelipase capsules was added to 20 mL of 8.4% sodium bicarbonate solution to dissolve the enteric coating and liberate the enzymes into solution. In addition to visual observation, the pH, relative particle count, and osmolality of each admixture were assessed immediately and 5, 10, 20, and 30 minutes after admixture preparation. The only dose of Creon that was completely dissolved at 30 minutes was the 24,000 lipase unit dose. None of the doses of Pancreaze and only the lowest dose (23,000 lipase units) of Ultresa were completely dissolved at 30 minutes. However, Zenpep doses of 20,000 and 40,000 lipase units were completely dissolved 30 minutes after preparation. Higher doses of each pancrelipase product did not completely dissolve. The baseline pH of the solvent decreased slightly at the first few time points after pancrelipase was added. The relative particle count increased over time and with increasing doses. The osmolality of the mixtures varied by pancrelipase product. The dissolution of enteric coated granules in sodium bicarbonate varied with the pancrelipase product and dose. Zenpep 40,000 lipase units was found to most efficiently dissolve in sodium bicarbonate, possibly due to the consistent size of the product's granules and visibly thinner and uniform enteric coating. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Human salmonellosis: estimation of dose-illness from outbreak data.

    PubMed

    Bollaerts, Kaatje; Aerts, Marc; Faes, Christel; Grijspeerdt, Koen; Dewulf, Jeroen; Mintiens, Koen

    2008-04-01

    The quantification of the relationship between the amount of microbial organisms ingested and a specific outcome such as infection, illness, or mortality is a key aspect of quantitative risk assessment. A main problem in determining such dose-response models is the availability of appropriate data. Human feeding trials have been criticized because only young healthy volunteers are selected to participate and low doses, as often occurring in real life, are typically not considered. Epidemiological outbreak data are considered to be more valuable, but are more subject to data uncertainty. In this article, we model the dose-illness relationship based on data of 20 Salmonella outbreaks, as discussed by the World Health Organization. In particular, we model the dose-illness relationship using generalized linear mixed models and fractional polynomials of dose. The fractional polynomial models are modified to satisfy the properties of different types of dose-illness models as proposed by Teunis et al. Within these models, differences in host susceptibility (susceptible versus normal population) are modeled as fixed effects whereas differences in serovar type and food matrix are modeled as random effects. In addition, two bootstrap procedures are presented. A first procedure accounts for stochastic variability whereas a second procedure accounts for both stochastic variability and data uncertainty. The analyses indicate that the susceptible population has a higher probability of illness at low dose levels when the combination pathogen-food matrix is extremely virulent and at high dose levels when the combination is less virulent. Furthermore, the analyses suggest that immunity exists in the normal population but not in the susceptible population.

  10. Multi-level effects of low dose rate ionizing radiation on southern toad, Anaxyrus [Bufo] terrestris

    DOE PAGES

    Stark, Karolina; Scott, David E.; Tsyusko, Olga; ...

    2015-04-30

    Despite their potential vulnerability to contaminants from exposure at multiple life stages, amphibians are one of the least studied groups of vertebrates in ecotoxicology, and research on radiation effects in amphibians is scarce. We used multiple endpoints to assess the radiosensitivity of the southern toad ( Anaxyrus [Bufo] terrestris) during its pre-terrestrial stages of development –embryonic, larval, and metamorphic. Toads were exposed, from several hours after oviposition through metamorphosis (up to 77 days later), to four low dose rates of ¹³⁷Cs at 0.13, 2.4, 21, and 222 mGy d⁻¹, resulting in total doses up to 15.8 Gy. Radiation treatments didmore » not affect hatching success of embryos, larval survival, or the length of the larval period. The individual family variation in hatching success of embryos was larger than the radiation response. In contrast, newly metamorphosed individuals from the higher dose-rate treatments had higher mass and mass/length body indices, a measure which may relate to higher post-metamorphic survival. The increased mass and index at higher dose rates may indicate that the chronic, low dose rate radiation exposures triggered secondary responses. Additionally, the increases in growth were linked to a decrease in DNA damage (as measured by the Comet Assay) in red blood cells at a dose rate of 21mGy d⁻¹ and a total dose of 1.1 Gy. In conclusion, the complex effects of low dose rates of ionizing radiation may trigger growth and cellular repair mechanisms in amphibian larvae.« less

  11. Occupational radiation exposure in vascular interventional radiology: A complete evaluation of different body regions.

    PubMed

    Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Nicolucci, Patrícia; Pina, Diana Rodrigues de

    2016-08-01

    To perform a complete evaluation on radiation doses, received by primary and assistant medical staff, while performing different vascular interventional radiology procedures. We evaluated dose received in different body regions during three categories of vascular procedures: lower limb angiography (Angiography), lower limb percutaneous transluminal angioplasty (Angioplasty) and stent graft placement for abdominal aortic aneurysm treatment (A. A. A. Treatment). We positioned the dosimeters near the eye lens, thyroid, chest, abdomen, hands, and feet of the interventional physicians. Equivalent dose was compared with annual dose limits for workers in order to determine the maximum number of procedures per year that each physician could perform. We assessed 90 procedures. We found the highest equivalent doses in the A. A. A. Treatment, in which 90% of the evaluations indicated at least one region receiving more than 1mSv per procedure. Angioplasty was the only procedural modality that provided statistically different doses for different professionals, which is an important aspect on regards to radiological protection strategies. In comparison with the dose limits, the most critical region in all procedures was the eye lens. Since each body region of the interventionist is exposed to different radiation levels, dose distribution measurements are essential for radiological protection strategies. These results indicate that dosimeters placed in abdomen instead of chest may represent more accurately the whole body doses received by the medical staff. Additional dosimeters and a stationary shield for the eye lens are strongly recommended. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Neurotoxicological and statistical analyses of a mixture of five organophosphorus pesticides using a ray design.

    PubMed

    Moser, V C; Casey, M; Hamm, A; Carter, W H; Simmons, J E; Gennings, C

    2005-07-01

    Environmental exposures generally involve chemical mixtures instead of single chemicals. Statistical models such as the fixed-ratio ray design, wherein the mixing ratio (proportions) of the chemicals is fixed across increasing mixture doses, allows for the detection and characterization of interactions among the chemicals. In this study, we tested for interaction(s) in a mixture of five organophosphorus (OP) pesticides (chlorpyrifos, diazinon, dimethoate, acephate, and malathion). The ratio of the five pesticides (full ray) reflected the relative dietary exposure estimates of the general population as projected by the US EPA Dietary Exposure Evaluation Model (DEEM). A second mixture was tested using the same dose levels of all pesticides, but excluding malathion (reduced ray). The experimental approach first required characterization of dose-response curves for the individual OPs to build a dose-additivity model. A series of behavioral measures were evaluated in adult male Long-Evans rats at the time of peak effect following a single oral dose, and then tissues were collected for measurement of cholinesterase (ChE) activity. Neurochemical (blood and brain cholinesterase [ChE] activity) and behavioral (motor activity, gait score, tail-pinch response score) endpoints were evaluated statistically for evidence of additivity. The additivity model constructed from the single chemical data was used to predict the effects of the pesticide mixture along the full ray (10-450 mg/kg) and the reduced ray (1.75-78.8 mg/kg). The experimental mixture data were also modeled and statistically compared to the additivity models. Analysis of the 5-OP mixture (the full ray) revealed significant deviation from additivity for all endpoints except tail-pinch response. Greater-than-additive responses (synergism) were observed at the lower doses of the 5-OP mixture, which contained non-effective dose levels of each of the components. The predicted effective doses (ED20, ED50) were about half that predicted by additivity, and for brain ChE and motor activity, there was a threshold shift in the dose-response curves. For the brain ChE and motor activity, there was no difference between the full (5-OP mixture) and reduced (4-OP mixture) rays, indicating that malathion did not influence the non-additivity. While the reduced ray for blood ChE showed greater deviation from additivity without malathion in the mixture, the non-additivity observed for the gait score was reversed when malathion was removed. Thus, greater-than-additive interactions were detected for both the full and reduced ray mixtures, and the role of malathion in the interactions varied depending on the endpoint. In all cases, the deviations from additivity occurred at the lower end of the dose-response curves.

  13. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  14. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  15. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  16. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  17. 10 CFR 20.1003 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... assessment of dose equivalent by the use of devices designed to be worn by an individual; (2) The assessment... equipment) means devices designed to be worn by a single individual for the assessment of dose equivalent... radionuclide in a year by the reference man that would result in a committed effective dose equivalent of 5...

  18. Guideline adherence for pharmacotherapy of chronic systolic heart failure in general practice: a closer look on evidence-based therapy.

    PubMed

    Peters-Klimm, F; Müller-Tasch, T; Schellberg, D; Remppis, A; Barth, A; Holzapfel, N; Jünger, J; Herzog, W; Szecsenyi, J

    2008-04-01

    There is robust evidence for effective pharmacotherapy of chronic (systolic) heart failure (CHF) which has led to the creation of guidelines, but many surveys evaluating CHF treatment show an under-utilisation of relevant drugs, while setting and patient population appear to be crucial for adequate appraisal of treatment patterns. To evaluate the guideline adherence (GA) of general practitioners (GPs) in a well-defined patient population with CHF in primary care (PC). A cross-sectional analysis was performed with the data of 167 patients enrolled in 37 GP practices (Germany) with documented left ventricular systolic dysfunction (LVEF: 33.3 +/- 6.9%). GA was assessed as usual (prescribing "yes" or "no"), through evaluation of target dosing, while adjusting for potential clinical contraindications, and through a modified Guideline Adherence Indicator-3 (mGAI-3), which assesses three relevant groups of substances according to New York Heart Association (NYHA) functional class: ACE-Inhibitors (ACE-I) or angiotensin receptor blockers (ARB), beta-blockers (BB) and aldosterone-antagonists (AA). Prescription rates for ACE-I/ARB, BB or both were 80%, 75% and 62%, respectively. The proportion of target doses reached for ACE-I was 16%, for BB only 8%. When adjusted for potential (mainly relative) contraindications (COPD, heart rate <60/min, hypotension, hyperkalaemia and renal dysfunction), the percentage of target doses reached increased to 49% for ACE-I/ARBs and 46% for BB. Application of the mGAI-3 showed moderate to perfect GA for usual assessment, proportion of target dose reached and adjusted in 83%, 16% and 55% of the patients, respectively. In the context of this patient and doctor setting, life-saving treatment was provided above average when assessed by usual criteria. The application of additional criteria showed further room for improvement. Future interventions aiming at optimisation should be tailored to the needs of doctors and patients likewise.

  19. A proposed performance index for galactic cosmic ray shielding materials

    NASA Technical Reports Server (NTRS)

    Wilson, John W.; Wood, J. S.; Shinn, Judy L.; Cucinotta, Francis A.; Nealy, John E.

    1993-01-01

    In past studies, the reductions in absorbed dose and dose equivalent due to choice of material composition have been used to indicate shield effectiveness against exposure to galactic cosmic rays. However, these quantities are highly inaccurate in assessing shield effectiveness for protection against the biological effects of long-term exposure to the galactic heavy ions. A new quantity for shield performance is defined that correlates well with cell killing and cell transformation behind various shield thicknesses and materials. In addition, a relative performance index is identified that is inversely related to biological injury for different materials at a fixed shield mass and is directly related to the ratio of the fourth- and the second-order linear energy transfer (LET) moments.

  20. Dose assessment of aircraft crew in The Netherlands.

    PubMed

    Van Dijk, J W E

    2003-01-01

    As the operator of the National Dose Registration and Information System, NRG has implemented a system for radiation exposure monitoring for the Dutch airlines. The system is based on the use of computer generated flight plans together with dose calculations using the CARI-6M program. Before installing the system a study was performed to estimate the uncertainty in the assessment of the annual dose of the crew members. It was concluded that the proposed system complies with international recommendations on the uncertainty in dose assessments in individual monitoring and that the operational costs of the system are low.

Top