Science.gov

Sample records for additional light source

  1. Light Source

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Research on food growth for long duration spacecraft has resulted in a light source for growing plants indoors known as Qbeam, a solid state light source consisting of a control unit and lamp. The light source, manufactured by Quantum Devices, Inc., is not very hot, although it generates high intensity radiation. When Ron Ignatius, an industrial partner of WCSAR, realized that terrestrial plant research lighting was not energy efficient enough for space use, he and WCSAR began to experiment with light emitting diodes. A line of LED products was developed, and QDI was formed to market the technology. An LED-based cancer treatment device is currently under development.

  2. Photonic crystal light source

    DOEpatents

    Fleming, James G.; Lin, Shawn-Yu; Bur, James A.

    2004-07-27

    A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.

  3. Light Sources and Lighting Circuits

    NASA Astrophysics Data System (ADS)

    Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki

    According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by

  4. National Synchrotron Light Source

    ScienceCinema

    BNL

    2016-07-12

    A tour of Brookhaven's National Synchrotron Light Source (NSLS), hosted by Associate Laboratory Director for Light Sources, Stephen Dierker. The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviolet, and x-ray light for basic and applied research in physics, chemistry, medicine, geophysics, environmental, and materials sciences.

  5. National Synchrotron Light Source

    SciTech Connect

    2009-03-10

    A tour of Brookhaven's National Synchrotron Light Source (NSLS). The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviole

  6. National Synchrotron Light Source

    ScienceCinema

    None

    2016-07-12

    A tour of Brookhaven's National Synchrotron Light Source (NSLS). The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviole

  7. MEMS Incandescent Light Source

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret; King, Kevin; Kim, Lynn; Hansler, Richard; Jones, Eric; George, Thomas

    2001-01-01

    A MEMS-based, low-power, incandescent light source is being developed. This light source is fabricated using three bonded chips. The bottom chip consists of a reflector on Silicon, the middle chip contains a Tungsten filament bonded to silicon and the top layer is a transparent window. A 25-micrometer-thick spiral filament is fabricated in Tungsten using lithography and wet-etching. A proof-of-concept device has been fabricated and tested in a vacuum chamber. Results indicate that the filament is electrically heated to approximately 2650 K. The power required to drive the proof-of-concept spiral filament to incandescence is 1.25 W. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 microns. The micromachining techniques used to fabricate this light source can be applied to other MEMS devices.

  8. Light source modeling for automotive lighting devices

    NASA Astrophysics Data System (ADS)

    Zerhau-Dreihoefer, Harald; Haack, Uwe; Weber, Thomas; Wendt, Dierk

    2002-08-01

    Automotive lighting devices generally have to meet high standards. For example to avoid discomfort glare for the oncoming traffic, luminous intensities of a low beam headlight must decrease by more than one order of magnitude within a fraction of a degree along the horizontal cutoff-line. At the same time, a comfortable homogeneous illumination of the road requires slowly varying luminous intensities below the cutoff line. All this has to be realized taking into account both, the legal requirements and the customer's stylistic specifications. In order to be able to simulate and optimize devices with a good optical performance different light source models are required. In the early stage of e.g. reflector development simple unstructured models allow a very fast development of the reflectors shape. On the other hand the final simulation of a complex headlamp or signal light requires a sophisticated model of the spectral luminance. In addition to theoretical models based on the light source's geometry, measured luminance data can also be used in the simulation and optimization process.

  9. Development of a circadian light source

    NASA Astrophysics Data System (ADS)

    Nicol, David B.; Ferguson, Ian T.

    2002-11-01

    Solid state lighting presents a new paradigm for lighting - controllability. Certain characteristics of the lighting environment can be manipulated, because of the possibility of using multiple LEDs of different emission wavelengths as the illumination source. This will provide a new, versatile, general illumination source due to the ability to vary the spectral power distribution. New effects beyond the visual may be achieved that are not possible with conventional light sources. Illumination has long been the primary function of lighting but as the lighting industry has matured the psychological aspects of lighting have been considered by designers; for example, choosing a particular lighting distribution or color variation in retail applications. The next step in the evolution of light is to consider the physiological effects of lighting that cause biological changes in a person within the environment. This work presents the development of a source that may have important bearing on this area of lighting. A circadian light source has been developed to provide an illumination source that works by modulating its correlated color temperature to mimic the changes in natural daylight through the day. In addition, this source can cause or control physiological effects for a person illuminated by it. The importance of this is seen in the human circadian rhythm's peak response corresponding to blue light at ~460 nm which corresponds to the primary spectral difference in increasing color temperature. The device works by adding blue light to a broadband source or mixing polychromatic light to mimic the variation of color temperature observed for the Planckian Locus on the CIE diagram. This device can have several applications including: a tool for researchers in this area, a general illumination lighting technology, and a light therapy device.

  10. The Linac Coherent Light Source

    SciTech Connect

    White, William E.; Robert, Aymeric; Dunne, Mike

    2015-05-01

    The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.

  11. The Linac Coherent Light Source

    SciTech Connect

    White, William E.; Robert, Aymeric; Dunne, Mike

    2015-04-21

    The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.

  12. Fusion pumped light source

    DOEpatents

    Pappas, Daniel S.

    1989-01-01

    Apparatus is provided for generating energy in the form of light radiation. A fusion reactor is provided for generating a long, or continuous, pulse of high-energy neutrons. The neutron flux is coupled directly with the lasing medium. The lasing medium includes a first component selected from Group O of the periodic table of the elements and having a high inelastic scattering cross section. Gamma radiation from the inelastic scattering reactions interacts with the first component to excite the first component, which decays by photon emission at a first output wavelength. The first output wavelength may be shifted to a second output wavelength using a second liquid component responsive to the first output wavelength. The light outputs may be converted to a coherent laser output by incorporating conventional optics adjacent the laser medium.

  13. Light Sources and Ballast Circuits

    NASA Astrophysics Data System (ADS)

    Yorifuji, Takashi; Sakai, Makoto; Yasuda, Takeo; Maehara, Akiyoshi; Okada, Atsunori; Gouriki, Takeshi; Mannami, Tomoaki

    discharge models were reported. Further, studies on ultra high-pressure mercury lamps as light sources for projectors are becoming the mainstream of HID lamp related researches. For high-pressure sodium lamps, many studies on plant growing and pest control utilizing low insect attracting aspects were also reported in 2006. Additionally, for discharge lamps, the minimum sustaining electric power for arc tubes employed in electrode-less compact fluorescent lamps was investigated. For Hg-free rare-gas fluorescent lamps, a luminance of 10,000cd/m2 was attained by a 1 meter-long external duplex spiral electrode prototype using Xe/Ne barrier discharge. As to startup circuits, the commercialization of energy saving and high value added products mainly associated with fluorescent lamps and HID lamps are becoming common. Further, the miniaturization of startup circuits for self electronic-ballasted lamps has advanced. Speaking of the overall light sources and startup circuits in 2006 and with the enforcement of RoHS in Europe in July, the momentum toward hazardous substance-free and energy saving initiatives has been enhanced from the perspective of protecting the global environment. It is anticipated that similar restrictions will be globally enforced in the future.

  14. Synchrotron light source data book

    SciTech Connect

    Murphy, J.

    1989-01-01

    The ''Synchrotron Light Source Data Book'' is as its name implies a collection of data on existing and planned synchrotron light sources. The intention was to provide a compendium of tools for the design of electron storage rings as synchrotron radiation sources. The slant is toward the accelerator physicist as other booklets such as the X-ray Data Booklet, edited by D. Vaughan (LBL PUB-490), address the 'use' of synchrotron radiation. It is hoped that the booklet serves as a pocket sized reference to facilitate back of the envelope type calculations. It contains some useful formulae in 'practical units' and a brief description of many of the existing and planned light source lattices.

  15. Backscatter absorption gas imaging systems and light sources therefore

    DOEpatents

    Kulp, Thomas Jan; Kliner, Dahv A. V.; Sommers, Ricky; Goers, Uta-Barbara; Armstrong, Karla M.

    2006-12-19

    The location of gases that are not visible to the unaided human eye can be determined using tuned light sources that spectroscopically probe the gases and cameras that can provide images corresponding to the absorption of the gases. The present invention is a light source for a backscatter absorption gas imaging (BAGI) system, and a light source incorporating the light source, that can be used to remotely detect and produce images of "invisible" gases. The inventive light source has a light producing element, an optical amplifier, and an optical parametric oscillator to generate wavelength tunable light in the IR. By using a multi-mode light source and an amplifier that operates using 915 nm pump sources, the power consumption of the light source is reduced to a level that can be operated by batteries for long periods of time. In addition, the light source is tunable over the absorption bands of many hydrocarbons, making it useful for detecting hazardous gases.

  16. Characterization of multiple light sources

    NASA Astrophysics Data System (ADS)

    Casas, Jessica Marie

    The integrating cavity absorption meter (ICAM) is an instrument that utilizes the absorption of water to detect alien substances in the water. The ICAM was first proposed by Elterman in 1970 and has since been enhanced by other scientists such as Kirk, Leathers, Fry, Musser, and Gray. While others have investigated the structure of the ICAM, little research has been published regarding the most efficient light source. This thesis compares the power consumption, spectral stability, and output intensity of three different light sources to determine which should be used in the ICAM to further develop its capabilities.

  17. National Synchrotron Light Source II

    ScienceCinema

    Steve Dierker

    2016-07-12

    The National Synchrotron Light Source II (NSLS-II) at the U.S. Department of Energy's Brookhaven National Laboratory is a proposed new state-of-the-art medium energy storage ring designed to deliver world-leading brightness and flux with top-off operation

  18. National Synchrotron Light Source II

    SciTech Connect

    Steve Dierker

    2008-03-12

    The National Synchrotron Light Source II (NSLS-II) at the U.S. Department of Energy's Brookhaven National Laboratory is a proposed new state-of-the-art medium energy storage ring designed to deliver world-leading brightness and flux with top-off operation

  19. The Brazilian Synchrotron Light Source

    SciTech Connect

    Brum, J. A.; Tavares, P. F.

    2007-01-19

    The Brazilian Synchrotron Light Laboratory has been operating the only light source in the southern hemisphere since July 1997. During this period, approximately 28000 hours of beam time were delivered reaching more than 1000 users per year from all over Brazil as well as from 10 other countries. In this paper, we briefly recall the history of the project and describe the present configuration of the machine and associated instrumentation, focusing on improvements and upgrades of the various light source subsystems and beamlines implemented in recent years. Finally, we report on the use of the facility by the national and international scientific communities, its impact on the scientific and technological scene in Brazil and present perspectives for future improvements of the machine.

  20. The First Sources of Light

    NASA Astrophysics Data System (ADS)

    Loeb, Avi

    2011-09-01

    Looking deep into the Universe through powerful telescopes, we can see images of the Universe when it was younger because of the finite time it takes light to travel to us from distant sources. Existing data sets include an image of the Universe when it was 0.4 million years old (in the form of the cosmic microwave background), as well as images of individual galaxies when the Universe was older than a billion years. But there is a serious challenge: in between these two epochs was a period when the Universe was dark, stars had not yet formed, and the cosmic microwave background no longer traced the distribution of matter. And this is precisely the most interesting period, when the primordial soup evolved into the rich zoo of objects we now see. The observers are moving ahead along several fronts. The first involves the construction of large infrared telescopes on the ground and in space, that will provide us with new photos of the first galaxies. Current plans include ground-based telescopes which are 24-42 meter in diameter, and NASA's successor to the Hubble Space Telescope, called the James Webb Space Telescope. In addition, several observational groups around the globe are constructing radio arrays that will be capable of mapping the three-dimensional distribution of cosmic hydrogen in the infant Universe. These arrays are aiming to detect the long-wavelength (redshifted 21-cm) radio emission from hydrogen atoms. The images from these antenna arrays will reveal how the non-uniform distribution of neutral hydrogen evolved with cosmic time and eventually was extinguished by the ultra-violet radiation from the first galaxies. Theoretical research has focused in recent years on predicting the expected signals for the above instruments and motivating these ambitious observational projects.

  1. INTERMEDIATE-ENERGY LIGHT SOURCES

    SciTech Connect

    Corbett, William

    2002-11-25

    Increasingly, atomic scale information underlies scientific and technological progress in disciplines ranging from pharmaceutical development to materials synthesis to environmental remediation. While a variety of research tools are used to provide atomic scale information, synchrotron radiation has proved invaluable in this quest. The rapid growth of soft- and hard X-ray synchrotron light sources stands as stark testimony to the importance and utility of synchrotron radiation. Starting from just a handful of synchrotron light sources in the early 1970s, this burgeoning field now includes over 70 proposed, in-construction, or operating facilities in 23 countries on five continents. Along the way, synchrotron light facilities have evolved from small laboratories extracting light parasitically from storage rings designed for high-energy physics research to large, dedicated sources using the latest technology to produce extraordinarily bright photon beams. The basic layout of a multi-GeV storage ring light source employs periodic bending magnets to guide a charged particle beam around the storage ring. As the charged beam is accelerated in an arc, it produces a sweeping fan of synchrotron radiation that extends from the infrared part of the electromagnetic spectrum (<1 eV) to hard X rays (>20 keV). Quadrupole magnets keep the electrons tightly focused, and a radio-frequency acceleration system replenishes beam energy lost to radiation emission. To optimize the output radiation, a premium is placed on high current electron beams with small cross section and extreme position stability. Magnetic insertion devices are used to further enhance radiation output by a factor of 10 or more over bend magnet sources. The storage ring vacuum chamber includes exit ports to allow portions of the radiation fan to propagate down photon beam transport lines to optical systems and experimental stations. A typical storage ring features 10 or more such radiation ports. The photon beam

  2. Light pollution simulations for planar ground-based light sources.

    PubMed

    Kocifaj, Miroslav

    2008-02-20

    The light pollution model is employed to analyze spatial behavior of luminance at the night sky under cloudless and overcast conditions. Enhanced light excess is particularly identified at cloudy skies, because the clouds efficiently contribute to the downward luminous flux. It is evident that size of ground-based light sources can play an important role in the case of overcast sky conditions. Nevertheless, the realistically sized light sources are rarely embedded into light pollution modeling, and rather they are replaced by simple point sources. We discuss the discrepancies between sky luminance distributions when at first the planar light sources are considered and at second the point-source approximation is accepted. The found differences are noticeable if the size of the light source, distance to the observer, and altitude of a cloudy layer are comparable one to the other. Compared with point-source approximation, an inclusion of the size factor into modeling the light sources leads to partial elimination of the steep changes of sky luminance (typical for point sources of light). The narrow and sharp light pillars normally presented on the sky illuminated by point light sources can disappear or fuse together when two or more nearby light sources are considered with their real sizes. Sky elements situated close to the horizon will glow efficiently if luminous flux originates from two-dimensional ground-based entities (such as cities or villages).

  3. Driver circuit for solid state light sources

    DOEpatents

    Palmer, Fred; Denvir, Kerry; Allen, Steven

    2016-02-16

    A driver circuit for a light source including one or more solid state light sources, a luminaire including the same, and a method of so driving the solid state light sources are provided. The driver circuit includes a rectifier circuit that receives an alternating current (AC) input voltage and provides a rectified AC voltage. The driver circuit also includes a switching converter circuit coupled to the light source. The switching converter circuit provides a direct current (DC) output to the light source in response to the rectified AC voltage. The driver circuit also includes a mixing circuit, coupled to the light source, to switch current through at least one solid state light source of the light source in response to each of a plurality of consecutive half-waves of the rectified AC voltage.

  4. Light source design for machine vision

    NASA Astrophysics Data System (ADS)

    Sieczka, Eric J.; Harding, Kevin G.

    1992-03-01

    There is a lack of commercially available white light sources for machine vision applications. Current commercial sources are typically expensive and primarily designed for workbench use. Because of their benchtop design, these light sources cannot be easily integrated into the inspection system. In most cases a light source must be custom designed and built to suit the needs of the particular machine vision application. The materials being inspected can vary from highly specular to highly diffuse, thus requiring a broad range of illumination levels. Other issues important in machine vision light sources include efficiency, light divergence, spectral content, source size, and packaging. This paper discusses the issues that must be overcome when designing a light source for machine vision applications, and describes the work done by ITI to produce an efficient white light source with computer controlled illumination level.

  5. Advanced Light Source control system

    SciTech Connect

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.

    1989-03-01

    The Advanced Light Source (ALS) is a third generation 1--2 GeV synchrotron radiation source designed to provide ports for 60 beamlines. It uses a 50 MeV electron linac and 1.5 GeV, 1 Hz, booster synchrotron for injection into a 1--2 GeV storage ring. Interesting control problems are created because of the need for dynamic closed beam orbit control to eliminate interaction between the ring tuning requirements and to minimize orbit shifts due to ground vibrations. The extremely signal sensitive nature of the experiments requires special attention to the sources of electrical noise. These requirements have led to a control system design which emphasizes connectivity at the accelerator equipment end and a large I/O bandwidth for closed loop system response. Not overlooked are user friendliness, operator response time, modeling, and expert system provisions. Portable consoles are used for local operation of machine equipment. Our solution is a massively parallel system with >120 Mbits/sec I/O bandwidth and >1500 Mips computing power. At the equipment level connections are made using over 600 powerful Intelligent Local Controllers (ILC-s) mounted in 3U size Eurocard slots using fiber-optic cables between rack locations. In the control room, personal computers control and display all machine variables at a 10 Hz rate including the scope signals which are collected though the control system. Commercially available software and industry standards are used extensively. Particular attention is paid to reliability, maintainability and upgradeability. 10 refs., 11 figs.

  6. Silicon micromachined broad band light source

    NASA Technical Reports Server (NTRS)

    George, Thomas (Inventor); Jones, Eric (Inventor); Tuma, Margaret L. (Inventor); Eastwood, Michael (Inventor); Hansler, Richard (Inventor)

    2004-01-01

    A micro electromechanical system (MEMS) broad band incandescent light source includes three layers: a top transmission window layer; a middle filament mount layer; and a bottom reflector layer. A tungsten filament with a spiral geometry is positioned over a hole in the middle layer. A portion of the broad band light from the heated filament is reflective off the bottom layer. Light from the filament and the reflected light of the filament are transmitted through the transmission window. The light source may operate at temperatures of 2500 K or above. The light source may be incorporated into an on board calibrator (OBC) for a spectrometer.

  7. EDITORIAL: LED light sources (light for the future) LED light sources (light for the future)

    NASA Astrophysics Data System (ADS)

    Grandjean, N.

    2010-09-01

    comprehensive review of the different localization mechanisms and their implication for internal quantum efficiency (IQE) is proposed by Oliver and co-workers from Cambridge University. When discussing IQE in InGaN-based LEDs, the efficiency droop at high-current injection always emerges, which is a major concern for the future of SSL technology. Here, a collaborative work between Samsung and the Gwangju Institute of Science and Technology (Korea) proves that a specific design of the active region can limit this detrimental effect. Once the issue of the IQE is solved, one still has to let the photons out of the chip. Matioli and Weisbuch from the University of California at Santa Barbara introduce the use of photonic crystals (PhCs) to improve light extraction efficiency. They describe different approaches to overcoming the main limitation of LEDs when implementing surface PhCs. The technology of SSL, and in particular of colour rendering, is tackled by Zukauskas et al who studied in detail different white light sources. They show that extreme colour-fidelity indices need to cover the entire spectrum, with a broad-band at 530-610 nm and a component beyond 610 nm. Then, the reliability of GaN-based LEDs is discussed in the paper of Meneghesso and co-workers. The authors consider the most important physical mechanisms that are (i) the degradation of the active layer of LEDs, (ii) the degradation of the package/phosphor system, (iii) the failure of GaN-based LEDs against electrostatic discharge. Finally, GaN LEDs on silicon developed in the group of Egawa at the Nagoya Institute of Technology are presented. This technology could allow a significant decrease in the fabrication cost of white LEDs.

  8. 21 CFR 352.71 - Light source (solar simulator).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Light source (solar simulator). 352.71 Section 352... Light source (solar simulator). A solar simulator used for determining the SPF of a sunscreen drug... addition, a solar simulator should have no significant time-related fluctuations in radiation...

  9. 21 CFR 352.71 - Light source (solar simulator).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Light source (solar simulator). 352.71 Section 352... Light source (solar simulator). A solar simulator used for determining the SPF of a sunscreen drug... addition, a solar simulator should have no significant time-related fluctuations in radiation...

  10. Photometer for tracking a moving light source

    NASA Technical Reports Server (NTRS)

    Strawa, Anthony W. (Inventor)

    2009-01-01

    A photometer that tracks a path of a moving light source with little or no motion of the photometer components. The system includes a non-moving, truncated paraboloid of revolution, having a paraboloid axis, a paraboloid axis, a small entrance aperture, a larger exit aperture and a light-reflecting inner surface, that receives and reflects light in a direction substantially parallel to the paraboloid axis. The system also includes a light processing filter to receive and process the redirected light, and to issue the processed, redirected light as processed light, and an array of light receiving elements, at least one of which receives and measures an associated intensity of a portion of the processed light. The system tracks a light source moving along a path and produces a corresponding curvilinear image of the light source path on the array of light receiving elements. Undesired light wavelengths from the light source may be removed by coating a selected portion of the reflecting inner surface or another light receiving surface with a coating that absorbs incident light in the undesired wavelength range.

  11. Linac Coherent Light Source Electron Beam Collimation

    SciTech Connect

    Wu, J.; Dowell, D.; Emma, P.; Limborg-Deprey, C.; Schmerge, J.F.; /SLAC

    2007-04-27

    This paper describes the design and simulation of the electron beam collimation system in the Linac Coherent Light Source (LCLS). Dark current is expected from the gun and some of the accelerating cavities. Particle tracking of the expected dark current through the entire LCLS linac, from gun through FEL undulator, is used to estimate final particle extent in the undulator as well as expected beam loss at each collimator or aperture restriction. A table of collimators and aperture restrictions is listed along with halo particle loss results, which includes an estimate of average continuous beam power lost. In addition, the transverse wakefield alignment tolerances are calculated for each collimator.

  12. Tracking Steady Light Sources Amid Luminous Transients

    NASA Technical Reports Server (NTRS)

    Kissh, Frank; Fowski, Walter; Miklus, Kenneth; Abreu, Rene; Bolin, Kenneth; Flynn, David

    1994-01-01

    The Transient Event Rejection for Acquisition and Tracking (TERAT) algorithm governs operation of image-data-acquisition and -processing system. TERAT processes digitized image data to acquire (that is, identify) candidate steady source of light, validate candidate source, and track validated source, all in presence of real or apparent luminous transients represented in image data. Source of light tracked could be star or distant luminous beacon. Transients caused by impacts of ionizing radiation on imaging array of photodetectors or by unsteady light sources not meant to be tracked. TERAT functions with limited data-processing resources. TERAT algorithm currently operational on NASA's TOPEX mission.

  13. Superbend upgrade of the Advanced Light Source

    SciTech Connect

    Robin, D.; Krupnick, J.; Schlueter, R.; Steier, C.; Marks, S.; Wang, B.; Zbasnik, J.; Benjegerdes, R.; Biocca, A.; Bish, P.; Brown, W.; Byrne, W.; Chen, J.; Decking, W.; DeVries, J.; DeMarco, W.R.; Fahmie, M.; Geyer, A.; Harkins, J.; Henderson, T.; Hinkson, J.; Hoyer, E.; Hull, D.; Jacobson, S.; McDonald, J.; Molinari, P.; Mueller, R.; Nadolski, L.; Nishimura, H.; Nishimura, K.; Ottens, F.; Paterson, J.A.; Pipersky, P.; Portmann, G.; Richie, A.; Rossi, S.; Salvant, B.; Scarvie, T.; Schmidt,A.; Spring, J.; Taylor, C.; Thur, W.; Timossi, C.; Wandesforde, A.

    2004-05-26

    The Advanced Light Source (ALS) is a third generation synchrotron light source located at Lawrence Berkeley National Laboratory (LBNL). There was an increasing demand at the ALS for additional high brightness hard x-ray beamlines in the 7 to 40 keV range. In response to that demand, the ALS storage ring was modified in August 2001. Three 1.3 Tesla normal conducting bending magnets were removed and replaced with three 5 Tesla superconducting magnets (Superbends). The radiation produced by these Superbends is an order of magnitude higher in photon brightness and flux at 12 keV than that of the 1.3 Tesla bends, making them excellent sources of hard x-rays for protein crystallography and other hard x-ray applications. At the same time the Superbends did not compromise the performance of the facility in the VUV and soft x-ray regions of the spectrum. The Superbends will eventually feed 12 new beamlines greatly enhancing the facility's capability and capacity in the hard x-ray region. The Superbend project is the biggest upgrade to the ALS storage ring since it was commissioned in 1993. In this paper we present an overview of the Superbend project, its challenges and the resulting impact on the ALS.

  14. Microwave-driven ultraviolet light sources

    DOEpatents

    Manos, Dennis M.; Diggs, Jessie; Ametepe, Joseph D.

    2002-01-29

    A microwave-driven ultraviolet (UV) light source is provided. The light source comprises an over-moded microwave cavity having at least one discharge bulb disposed within the microwave cavity. At least one magnetron probe is coupled directly to the microwave cavity.

  15. The JLab high power ERL light source

    SciTech Connect

    G.R. Neil; C. Behre; S.V. Benson; M. Bevins; G. Biallas; J. Boyce; J. Coleman; L.A. Dillon-Townes; D. Douglas; H.F. Dylla; R. Evans; A. Grippo; D. Gruber; J. Gubeli; D. Hardy; C. Hernandez-Garcia; K. Jordan; M.J. Kelley; L. Merminga; J. Mammosser; W. Moore; N. Nishimori; E. Pozdeyev; J. Preble; R. Rimmer; Michelle D. Shinn; T. Siggins; C. Tennant; R. Walker; G.P. Williams and S. Zhang

    2005-03-19

    A new THz/IR/UV photon source at Jefferson Lab is the first of a new generation of light sources based on an Energy-Recovered, (superconducting) Linac (ERL). The machine has a 160 MeV electron beam and an average current of 10 mA in 75 MHz repetition rate hundred femtosecond bunches. These electron bunches pass through a magnetic chicane and therefore emit synchrotron radiation. For wavelengths longer than the electron bunch the electrons radiate coherently a broadband THz {approx} half cycle pulse whose average brightness is > 5 orders of magnitude higher than synchrotron IR sources. Previous measurements showed 20 W of average power extracted[1]. The new facility offers simultaneous synchrotron light from the visible through the FIR along with broadband THz production of 100 fs pulses with >200 W of average power. The FELs also provide record-breaking laser power [2]: up to 10 kW of average power in the IR from 1 to 14 microns in 400 fs pulses at up to 74.85 MHz repetition rates and soon will produce similar pulses of 300-1000 nm light at up to 3 kW of average power from the UV FEL. These ultrashort pulses are ideal for maximizing the interaction with material surfaces. The optical beams are Gaussian with nearly perfect beam quality. See www.jlab.org/FEL for details of the operating characteristics; a wide variety of pulse train configurations are feasible from 10 microseconds long at high repetition rates to continuous operation. The THz and IR system has been commissioned. The UV system is to follow in 2005. The light is transported to user laboratories for basic and applied research. Additional lasers synchronized to the FEL are also available. Past activities have included production of carbon nanotubes, studies of vibrational relaxation of interstitial hydrogen in silicon, pulsed laser deposition and ablation, nitriding of metals, and energy flow in proteins. This paper will present the status of the system and discuss some of the discoveries we have made

  16. Status of the Synchrotron Light Source DELTA

    SciTech Connect

    Berges, U.; Sternemann, C.; Tolan, M.; Westphal, C.; Weis, T.; Wille, K.

    2007-01-19

    The Dortmund Electron Accelerator DELTA, a 1.5 GeV synchrotron light source located at University of Dortmund, is operated for 3000 h per year including 2000 h beam time for synchrotron radiation use and 1000 h for machine physics, optimisation and maintenance. The status of the synchrotron light source is presented with emphasis on the operation, commissioning and installation of beamlines and insertion devices. The soft X-ray undulator beamlines provide photon energies between 5 to 400 eV (U250) and 55 and 1500 eV (U55), respectively. One dipole beamline covers soft X-rays between 6 to 200 eV, and a second dipole beamline is used without a monochromator at 2.2 keV critical energy of the dipole spectrum. For photons in the hard X-ray regime, a superconducting asymmetric wiggler (SAW) with a field of 5.3 T and 7.9 keV critical energy was installed, providing circularly polarized X-rays in the range of 2 to 30 keV. Due to its broad radiation fan, three beamlines are simultaneously served. The first SAW-beamline with an energy range between 4 to 30 keV is in full operation, the second is under commissioning, serving the energy range between 2 to 30 keV. The third SAW beamline is near completion, additional dipole beamlines are under construction.

  17. Measuring color quality of light sources

    NASA Astrophysics Data System (ADS)

    Davis, Wendy

    2006-08-01

    The successful commercialization of solid-state lighting for general illumination will require an effective method to characterize the color quality of these sources. The distinctive spectral characteristics of solid-state lighting sources present both unique challenges and opportunities with regards to color quality. Color quality is difficult to define, much less measure. Several aspects of color quality, including color fidelity (rendering), chromatic discrimination, and general population preferences must be considered. In some instances, these factors are contradictory. For example, observers tend to prefer lamps that increase object color chroma (vividness), though such chroma increases are deviations from color fidelity. In addition to devising a way to balance the influence of these different dimensions of color quality, consideration must be given to ways of communicating color quality in a simple way, which permits comparison between products. At NIST we're approaching this problem by developing a computational method that takes inspiration from the Color Rendering Index (CRI), but incorporates other aspects of color quality. The output of this Color Quality Scale (CQS) is a composite score incorporating a lamp's ability to accurately render object colors, permit precise discrimination between different colors, and display object colors in a way that is visually pleasing to typical consumers. Visual experimentation will be vital to improve and validate this method, which was initially developed with colorimetric simulations. Preliminary experimentation has begun, focusing on the issues most relevant to the development of commercial standards for color quality.

  18. Status of the SAGA Light Source

    SciTech Connect

    Kaneyasu, T.; Takabayashi, Y.; Iwasaki, Y.; Koda, S.

    2010-06-23

    The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

  19. Advanced Light Source Activity Report 2002

    SciTech Connect

    Duque, Theresa; Greiner, Annette; Moxon, Elizabeth; Robinson, Arthur; Tamura, Lori

    2003-06-12

    This annual report of the Advanced Light Source details science highlights and facility improvements during the year. It also offers information on events sponsored by the facility, technical specifications, and staff and publication information.

  20. Red Shifts with Obliquely Approaching Light Sources.

    ERIC Educational Resources Information Center

    Head, C. E.; Moore-Head, M. E.

    1988-01-01

    Refutes the Doppler effect as the explanation of large red shifts in the spectra of distant galaxies and explains the relativistic effects in which the light sources approach the observer obliquely. Provides several diagrams and graphs. (YP)

  1. National Synchrotron Light Source annual report 1988

    SciTech Connect

    Hulbert, S.; Lazarz, N.; Williams, G.

    1988-01-01

    This report discusses the experiment done at the National Synchrotron Light Source. Most experiments discussed involves the use of the x-ray beams to study physical properties of solid materials. (LSP)

  2. Advanced Light Source Activity Report 2000

    SciTech Connect

    Greiner, A.; Moxon, L.; Robinson, A.; Tamura, L.

    2001-04-01

    This is an annual report, detailing activities at the Advanced Light Source for the year 2000. It includes highlights of scientific research by users of the facility as well as information about the development of the facility itself.

  3. Depolarized light source for fiber optic sensors

    NASA Astrophysics Data System (ADS)

    Burns, W. K.; Moeller, R. P.

    1991-12-01

    An apparatus comprised of a depolarized light source for fiber optic sensors is disclosed. In a preferred embodiment, the depolarized light source of the apparatus comprises: a first laser for generating a first beam at a first frequency with the first beam having a linear polarization state; a second laser for generating a second beam at a second frequency with the second beam having a linear polarization state; a means for rotating the polarization state of the second beam so that the first and second beams have orthogonal linear polarization states with respect to each other; and a means for combining the first beam with the polarization-rotated second beam to obtain a composite beam which is depolarized. In a system operation, the apparatus comprises a source of depolarized light; an integrated optic modulator means for receiving a modulator drive signal; a first low-birefringence fiber for conveying the depolarized light beam from the depolarized light source to the integrated optic modulator means (the integrated optic modulator mean modulating only one linear polarization state in the depolarized light beam as a function of the modulator drive signal to produce a modulated beam); a photodetector; and a second low-birefringence fiber for conveying the modulated light beam to the photodetector with the photodetector being responsive to the modulated light beam for developing an electrical signal proportional to the modulator drive signal.

  4. Ideas for future synchrotron light sources

    SciTech Connect

    Jackson, A.; Hassenzahl, W.; Meddahi, M.

    1992-03-01

    Synchrotron light sources have advanced in the past two-to-three decades through three ``generations,`` from irritating parasitic sources on high-energy physics accelerators to dedicated electron and position storage rings of unprecedented low emittance, utilizing undulator and wiggler magnets. The evolution through these three generations followed a predicable, science-driven, course towards brighter beams of VUV- and x-radiation. The requirements of future light sources is not so clear. The limit on how emittance has certainly not been reached, and diffraction-limited sources at shorter wavelengths would be the natural progression from previous generations. However, scientists are now looking at other radiation characteristics that might better serve their needs, for example, more coherent power, fast switching polarization, ultra-short (sub-picosecond) time structure, and synchronized beams for pump-probe experiments. This paper discusses some current ideas that might drive the fourth-generation synchrotron light source.

  5. Ideas for future synchrotron light sources

    SciTech Connect

    Jackson, A.; Hassenzahl, W.; Meddahi, M.

    1992-03-01

    Synchrotron light sources have advanced in the past two-to-three decades through three generations,'' from irritating parasitic sources on high-energy physics accelerators to dedicated electron and position storage rings of unprecedented low emittance, utilizing undulator and wiggler magnets. The evolution through these three generations followed a predicable, science-driven, course towards brighter beams of VUV- and x-radiation. The requirements of future light sources is not so clear. The limit on how emittance has certainly not been reached, and diffraction-limited sources at shorter wavelengths would be the natural progression from previous generations. However, scientists are now looking at other radiation characteristics that might better serve their needs, for example, more coherent power, fast switching polarization, ultra-short (sub-picosecond) time structure, and synchronized beams for pump-probe experiments. This paper discusses some current ideas that might drive the fourth-generation synchrotron light source.

  6. Microelectromechanical Systems (MEMS) Broadband Light Source Developed

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L.

    2003-01-01

    A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip

  7. Light emitting diodes as a plant lighting source

    NASA Technical Reports Server (NTRS)

    Bula, R. J.; Tennessen, D. J.; Morrow, R. C.; Tibbitts, T. W.

    1994-01-01

    Electroluminescence in solid materials is defined as the generation of light by the passage of an electric current through a body of solid material under an applied electric field. A specific type of electroluminescence, first noted in 1923, involves the generation of photons when electrons are passed through a p-n junction of certain solid materials (junction of a n-type semiconductor, an electron donor, and a p-type semiconductor, an electron acceptor). The development of this light emitting semiconductor technology dates back less than 30 years. During this period of time, the LED has evolved from a rare and expensive light generating device to one of the most widely used electronic components. A number of LED characteristics are of considerable importance in selecting a light source for plant lighting in a controlled environment facility. Of particular importance is the characteristic that light is generated by an LED at a rate far greater than the corresponding thermal radiation predicted by the bulk temperature of the device as defined by Plank's radiation law. This is in sharp contrast to other light sources, such as an incandescent or high intensity discharge lamp. A plant lighting system for controlled environments must provide plants with an adequate flux of photosynthetically active radiation, plus providing photons in the spectral regions that are involved in the photomorphogenic and phototropic responses that result in normal plant growth and development. Use of light sources that emit photons over a broad spectral range generally meet these two lighting requirements. Since the LED's emit over specific spectral regions, they must be carefully selected so that the levels of photsynthetically active and photomorphogenic and phototropic radiation meet these plant requirements.

  8. Simulations of light propagation in biological tissues by considering the modeling of light sources and sensors

    NASA Astrophysics Data System (ADS)

    Klinger, David; Kraitl, Jens; Ewald, Hartmut

    2013-02-01

    Simulations of light propagation in biological tissues are a useful method in detector development for tissue spectroscopy. In practice most attention is paid to the adequate description of tissue structures and the ray trace procedure. The surrounding light source geometry, such as output window, reflector and casing is neglected. Instead, the description of the light source is usually reduced to incident beam paths. This also applies to detectors and further surrounding tissue connected sensor geometry. This paper discusses the influence of a complex and realistic description of the light source and detector geometry with the ray tracing software ASAP (Breault Research Organization). Additionally simulations include the light distribution curve in respect to light propagation through the tissue model. It was observed that the implementation of the geometric elements of the light source and the detector have direct influence on the propagation paths, average photon penetration depth, average photon path length and detected photon energy. The results show the importance of the inclusion of realistic geometric structures for various light source, tissue and sensor scenarios, especially for reflectance measurements. In reality the tissue surrounding sensor geometry has a substantial impact on surface and subsurface reflectance and transmittance due to the fact that a certain amount of photons are prevented from leaving the tissue model. Further improvement allows a determination of optimal materials and geometry for the light source and sensors to increase the number of light-tissue-interactions by the incident photons.

  9. High-intensity sources for light ions

    SciTech Connect

    Leung, K.N.

    1995-10-01

    The use of the multicusp plasma generator as a source of light ions is described. By employing radio-frequency induction discharge, the performance of the multicusp source is greatly improved, both in lifetime and in high brightness H{sup +} and H{sup {minus}} beam production. A new technique for generating multiply-charged ions in this type of ion source is also presented.

  10. The Jefferson Lab High Power Light Source

    SciTech Connect

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  11. Light sources based on semiconductor current filaments

    DOEpatents

    Zutavern, Fred J.; Loubriel, Guillermo M.; Buttram, Malcolm T.; Mar, Alan; Helgeson, Wesley D.; O'Malley, Martin W.; Hjalmarson, Harold P.; Baca, Albert G.; Chow, Weng W.; Vawter, G. Allen

    2003-01-01

    The present invention provides a new type of semiconductor light source that can produce a high peak power output and is not injection, e-beam, or optically pumped. The present invention is capable of producing high quality coherent or incoherent optical emission. The present invention is based on current filaments, unlike conventional semiconductor lasers that are based on p-n junctions. The present invention provides a light source formed by an electron-hole plasma inside a current filament. The electron-hole plasma can be several hundred microns in diameter and several centimeters long. A current filament can be initiated optically or with an e-beam, but can be pumped electrically across a large insulating region. A current filament can be produced in high gain photoconductive semiconductor switches. The light source provided by the present invention has a potentially large volume and therefore a potentially large energy per pulse or peak power available from a single (coherent) semiconductor laser. Like other semiconductor lasers, these light sources will emit radiation at the wavelength near the bandgap energy (for GaAs 875 nm or near infra red). Immediate potential applications of the present invention include high energy, short pulse, compact, low cost lasers and other incoherent light sources.

  12. Infrared light sources with semimetal electron injection

    DOEpatents

    Kurtz, Steven R.; Biefeld, Robert M.; Allerman, Andrew A.

    1999-01-01

    An infrared light source is disclosed that comprises a layered semiconductor active region having a semimetal region and at least one quantum-well layer. The semimetal region, formed at an interface between a GaAsSb or GalnSb layer and an InAsSb layer, provides electrons and holes to the quantum-well layer to generate infrared light at a predetermined wavelength in the range of 2-6 .mu.m. Embodiments of the invention can be formed as electrically-activated light-emitting diodes (LEDs) or lasers, and as optically-pumped lasers. Since the active region is unipolar, multiple active regions can be stacked to form a broadband or multiple-wavelength infrared light source.

  13. Physics Challenges for ERL Light Sources

    SciTech Connect

    Lia Merminga

    2004-07-01

    We present an overview of the physics challenges encountered in the design and operation of Energy Recovering Linac (ERL) based light sources. These challenges include the generation and preservation of low emittance, high-average current beams, manipulating and preserving the transverse and longitudinal phase space, control of the multipass beam breakup instability, efficient extraction of higher order mode power and RF control and stability of the superconducting cavities. These key R&D issues drive the design and technology choices for proposed ERL light sources. Simulations and calculations of these processes will be presented and compared with experimental data obtained at the Jefferson Lab FEL Upgrade, a 10 mA ERL light source presently in commissioning, and during a 1 GeV demonstration of energy recovery at CEBAF.

  14. National Synchrotron Light Source 2008 Activity Report

    SciTech Connect

    Nasta,K.

    2009-05-01

    Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R&D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for work

  15. Solid-State Spectral Light Source System

    NASA Technical Reports Server (NTRS)

    Maffione, Robert; Dana, David

    2011-01-01

    A solid-state light source combines an array of light-emitting diodes (LEDs) with advanced electronic control and stabilization over both the spectrum and overall level of the light output. The use of LEDs provides efficient operation over a wide range of wavelengths and power levels, while electronic control permits extremely stable output and dynamic control over the output. In this innovation, LEDs are used instead of incandescent bulbs. Optical feedback and digital control are used to monitor and regulate the output of each LED. Because individual LEDs generate light within narrower ranges of wavelengths than incandescent bulbs, multiple LEDs are combined to provide a broad, continuous spectrum, or to produce light within discrete wavebands that are suitable for specific radiometric sensors.

  16. Tunable pulsed narrow bandwidth light source

    DOEpatents

    Powers, Peter E.; Kulp, Thomas J.

    2002-01-01

    A tunable pulsed narrow bandwidth light source and a method of operating a light source are provided. The light source includes a pump laser, first and second non-linear optical crystals, a tunable filter, and light pulse directing optics. The method includes the steps of operating the pump laser to generate a pulsed pump beam characterized by a nanosecond pulse duration and arranging the light pulse directing optics so as to (i) split the pulsed pump beam into primary and secondary pump beams; (ii) direct the primary pump beam through an input face of the first non-linear optical crystal such that a primary output beam exits from an output face of the first non-linear optical crystal; (iii) direct the primary output beam through the tunable filter to generate a sculpted seed beam; and direct the sculpted seed beam and the secondary pump beam through an input face of the second non-linear optical crystal such that a secondary output beam characterized by at least one spectral bandwidth on the order of about 0.1 cm.sup.-1 and below exits from an output face of the second non-linear optical crystal.

  17. Mobile-phone based visible light communication using region-grow light source tracking for unstable light source.

    PubMed

    Liang, Kevin; Chow, Chi-Wai; Liu, Yang

    2016-07-25

    In order to increase the data rate of the camera-based visible light communication (VLC) system, using rolling shutter effect has been demonstrated successfully, in which the pixel rows of the complementary-metal-oxide-semiconductor (CMOS) image sensor are activated sequentially. Previous camera-based VLCs focused on using a stable LED light source, and its illumination area is positioned at the center of an image frame. In this work, we investigate the performance of a camera-based VLC with light source at different parts of an image frame. We propose and demonstrate using region-grow algorithm to track the light source. We also evaluate and discuss different scenarios when the light source is moved. Besides, a recorded > 5 kbit/s net data rate can be achieved by using only a single phosphor-based white-light LED source. Here, we demonstrate that 4.502 pixel/bit can be achieved.

  18. An Upgrade for the Advanced Light Source

    SciTech Connect

    Chemla, Daniel S.; Feinberg, Benedict; Hussain, Zahid; Kirz, Janos; Krebs, Gary F.; Padmore, Howard A.; Robin, David S.; Robinson, Arthur L.; Smith, Neville V.

    2004-09-01

    One of the first third-generation synchrotron light sources, the ALS, has been operating for almost a decade at Berkeley Lab, where experimenters have been exploiting its high brightness for forefront science. However, accelerator and insertion-device technology have significantly changed since the ALS was designed. As a result, the performance of the ALS is in danger of being eclipsed by that of newer, more advanced sources. The ALS upgrade that we are planning includes full-energy, top-off injection with higher storage-ring current and the replacement of five first-generation insertion devices with nine state-of-the art insertion devices and four new application-specific beamlines now being identified in a strategic planning process. The upgrade will help keep the ALS at the forefront of soft x-ray synchrotron light sources for the next two decades.

  19. Superluminescent Diode Light Sources for OCT

    NASA Astrophysics Data System (ADS)

    Shidlovski, Vladimir R.

    Contrary to laser diodes, the path of superluminescent diodes (SLDs) to widespread practical use was much longer. There was always a scientific interest in "superluminescent" light output from laser diode structures slightly below threshold that might be considerably enhanced by "damping" of the laser resonator. SLD design efforts were intensified in early 1980s when it was proved that they are "light sources of choice" for fiber-optic gyroscopes. The next wave of interest to SLDs as a "stand-alone" type of semiconductor emitters was related to advances in OCT technologies. Challenging OCT requirements, e.g. simultaneous high-power, high brightness and very low coherence length of a light source, resulted in the development of new generation of SLDs characterized by output power and brightness the same as that of medium-to-high power laser diodes, but with the spectral width and flatness of edge-emitting LEDs. In this chapter, the main principles of the development of powerful broadband SLDs and ultra-low-coherence SLD-based light sources in 650-1600 nm spectral range, and the main parameters reported to date, are reviewed. Important aspects of SLD use in practice are discussed.

  20. The sources of light and lighting at work.

    PubMed

    Lampi, E

    1984-01-01

    Succeeding in lighting industrial, office and other work environments is dependent on many factors. Good result is not guaranteed if only one of these factors is taken into account. It is essential to choose appropriate light sources and use them correctly for different tasks. Although the amount of light and its composition is considered satisfactory for a certain task, glare and reflected glare still cause inconvenience in the work places making the performance of visual tasks difficult. The lux and luminance levels of the work areas regulate the size of the observer's pupils. The size of the pupil determines for its part how easily and quickly eyes can be accommodated for a sight distance. The indirect disadvantages caused by poor visual conditions are often significant. For example at display work reflected glare does not only slow down reading. The effort to avoid the reflections from the screen by changing the direction of observation effects the working positions. Inconvenient posture may cause pains in the neck and back. In lighting design the problems of age vision are taken into account. We should also bear in mind the significance of the colour of light when considering these problems.

  1. IR beamline at the Swiss Light Source

    NASA Astrophysics Data System (ADS)

    Ph, Lerch; L, Quaroni; J, Wambach; J, Schneider; B, Armstrong D.; D, Rossetti; L, Mueller F.; P, Peier; V, Schlott; L, Carroll; P, Friedli; H, Sigg; S, Stutz; M, Tran

    2012-05-01

    The infrared beamline at the Swiss light source uses dipole radiation and is designed to transport light to four experimental stations, A, B, C, D. Branch A is dedicated to far IR work in vacuum; branch B is a micro-spectrometer; branch C is dedicated to high resolution spectroscopy in the gas phase; branch D is a pump and probe set-up. This contribution describes the optical layout and provides a brief survey of currently available experimental stations. The beamline is in regular user operation since 2009.

  2. The upgraded scheme of Hefei Light Source

    SciTech Connect

    Li Weimin; Xu Hongliang; Wang Lin; Feng Guangyao; Zhang Shancai; Hao Hao

    2010-06-23

    To enhance the performance of Hefei Light Source, which was designed and constructed two decades ago, an upgrade project would be carried out in the near future. The detail upgrade scheme was described in this paper. Firstly, the magnet lattice of storage ring should be reconstructed with 4 DBA cells, whose advantages are lower beam emittance and more straight section available for insertion devices. Secondly, the beam diagnostics, main power supply, transverse and longitudinal multi-bunch feedback, beam control and manipulation system would be upgrade to improve the beam orbit stability. Finally, the injection system of storage ring and injector, which is composed of electron linac and beam transfer line, would be updated in order to assure smooth beam accumulation process under new low emittance lattice. With above improvement, it is hopeful to increase the brilliance of Hefei Light Source by two orders approximately. After three-year upgrade project, the performance of HLS would meet the demands of advanced SR users.

  3. Rf capacitively-coupled electrodeless light source

    DOEpatents

    Manos, Dennis M.; Diggs, Jessie; Ametepe, Joseph D.; Fugitt, Jock A.

    2000-01-01

    An rf capacitively-coupled electrodeless light source is provided. The light source comprises a hollow, elongated chamber and at least one center conductor disposed within the hollow, elongated chamber. A portion of each center conductor extends beyond the hollow, elongated chamber. At least one gas capable of forming an electronically excited molecular state is contained within each center conductor. An electrical coupler is positioned concentric to the hollow, elongated chamber and the electrical coupler surrounds the portion of each center conductor that extends beyond the hollow, elongated chamber. A rf-power supply is positioned in an operable relationship to the electrical coupler and an impedance matching network is positioned in an operable relationship to the rf power supply and the electrical coupler.

  4. Photon Science at Modern Light Sources

    NASA Astrophysics Data System (ADS)

    Arthur, John

    2009-12-01

    More than 50 large x-ray and UV light sources based on high-energy electron accelerators are in operation around the world, serving a scientific community numbering in the tens of thousands. These sources generate synchrotron radiation from accelerated electrons or positrons. The development of synchrotron light sources over the last 40 years has fueled an exponential increase in x-ray source brightness of more than 10 orders of magnitude. The next large advance in source potential is now underway, with the commissioning of the first x-ray Free-Electron Laser (FEL) sources. Using high-energy electron linear accelerators, these facilities produce sub-picosecond pulses of hard x-rays with peak brightness more than 10 orders of magnitude greater than current synchrotron facilities. FEL x-ray facilities will soon be operational in the US, Japan, and Germany. Research at modern light sources makes use of a wide range of experimental techniques. Many experiments are designed to study the structure of matter at the atomic scale using elastic x-ray scattering. This technique has been particularly effective for determining the structures of biological molecules, such as proteins, viruses, and drugs. Inelastic x-ray scattering, or x-ray absorption followed by emission of electrons or photons, can give information about the electronic structures of atoms, which can be used to deduce local environment information such as atomic species, bonding state, geometry of neighboring atoms, or magnetic state. For some techniques involving x-ray emission from a sample, cryogenic detectors with energy resolution at the ˜10 eV level or better would be very helpful. Shifts in electron energy levels associated with bonding states and magnetic states are typically several eV, while the energy structure associated with Compton inelastic scattering is typically in the range of a few tens of eV. Current energy-resolving detectors used at synchrotron light sources are hampered by either poor

  5. Invitation to the World of the Plasma for Light Source 3.Light Source Measurement 3.1 Laser Diagnostics of Plasmas for Light Sources

    NASA Astrophysics Data System (ADS)

    Motomura, Hideki; Jinno, Masafumi

    Examples and basic theories of various methods of laser diagnostics of plasmas for light sources are introduced. Most introduced papers were presented at International Symposium on the Science and Technology of Light Sources (LS), which is the only international symposium on the science and technology of light sources.

  6. Linac Coherent Light Source Monte Carlo Simulation

    2006-03-15

    This suite consists of codes to generate an initial x-ray photon distribution and to propagate the photons through various objects. The suite is designed specifically for simulating the Linac Coherent Light Source, and x-ray free electron laser (XFEL) being built at the Stanford Linear Accelerator Center. The purpose is to provide sufficiently detailed characteristics of the laser to engineers who are designing the laser diagnostics.

  7. Advanced Light Source Linac subharmonic buncher cavities

    SciTech Connect

    Lo, C.C.; Taylor, B.; Lancaster, H.; Guigli, J.

    1989-03-01

    The Linear Accelerator (Linac) in the Advanced Light Source (ALS) is designed to provide either single or multiple bunches of 50 MeV electrons for the booster synchrotron. Three bunchers are used in the Linac. The 3 GHz S band buncher has been described elsewhere. This report deals with the two lower subharmonic bunchers. One operates at 124.914 MHz while the other operates at 499.654 MHz. 12 refs., 2 figs.

  8. Directly Phase-Modulated Light Source

    NASA Astrophysics Data System (ADS)

    Yuan, Z. L.; Fröhlich, B.; Lucamarini, M.; Roberts, G. L.; Dynes, J. F.; Shields, A. J.

    2016-07-01

    The art of imparting information onto a light wave by optical signal modulation is fundamental to all forms of optical communication. Among many schemes, direct modulation of laser diodes stands out as a simple, robust, and cost-effective method. However, the simultaneous changes in intensity, frequency, and phase have prevented its application in the field of secure quantum communication. Here, we propose and experimentally demonstrate a directly phase-modulated light source which overcomes the main disadvantages associated with direct modulation and is suitable for diverse applications such as coherent communications and quantum cryptography. The source separates the tasks of phase preparation and pulse generation between a pair of semiconductor lasers leading to very pure phase states. Moreover, the cavity-enhanced electro-optic effect enables the first example of subvolt half-wave phase modulation at high signal rates. The source is compact, stable, and versatile, and we show its potential to become the standard transmitter for future quantum communication networks based on attenuated laser pulses.

  9. Plasma-based EUV light source

    DOEpatents

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  10. The Advanced Light Source elliptically polarizing undulator

    SciTech Connect

    Marks, S.; Cortopassi, C.; DeVries, J.

    1997-05-01

    An elliptically polarizing undulator (EPU) for the Advanced Light Source (ALS) has been designed and is currently under construction. The magnetic design is a moveable quadrant pure permanent magnet structure featuring adjustable magnets to correct phase errors and on-axis field integrals. The device is designed with a 5.0 cm period and will produce variably polarized light of any ellipticity, including pure circular and linear. The spectral range at 1.9 GeV for typical elliptical polarization with a degree of circular polarization greater than 0.8 will be from 100 eV to 1,500 eV, using the first, third, and fifth harmonics. The device will be switchable between left and right circular modes at a frequency of up to 0.1 Hz. The 1.95 m long overall length will allow two such devices in a single ALS straight sector.

  11. Status of the Linac Coherent Light Source

    SciTech Connect

    Galayda, John N.; /SLAC

    2011-11-04

    The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

  12. Chemical Dynamics at the Advanced Light Source

    SciTech Connect

    Baer, T.; Berrah, N.; Fadley, C.; Moore, C.B.; Neumark, D.M.; Ng, C.Y.; Ruscic, B.; Smith, N.V.; Suits, A.G.; Wodtke, A.M.

    1999-02-02

    A day-long retreat was held January 15, 1999 to chart the future directions for chemical dynamics studies at the Advanced Light Source. This represents an important period for the Chemical Dynamics Beamline, as the hardware is well-developed, most of the initial experimental objectives have been realized and the mission is now to identify the future scientific priorities for the beamline and attract users of the highest caliber. To this end, we have developed a detailed scientific program for the near term; identified and prioritized the long range scientific opportunities, identified essential new hardware, and outlined an aggressive outreach program to involve the chemical physics community.

  13. Developing electron beam bunching technology for improving light sources

    SciTech Connect

    Carlsten, B.E.; Chan, K.C.D.; Feldman, D.W.

    1997-08-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goal of this project was to develop a new electron bunch compression technology, experimentally demonstrate subpicosecond compression of bunches with charges on the order of 1 nC, and to theoretically investigate fundamental limitations to electron bunch compression. All of these goals were achieved, and in addition, the compression system built for this project was used to generate 22 nm light in a plasma-radiator light source.

  14. Advanced Light Source: Activity report 1993

    SciTech Connect

    Not Available

    1994-11-01

    The Advanced Light Source (ALS) produces the world`s brightest light in the ultraviolet and soft x-ray regions of the spectrum. The first low-energy third-generation synchrotron source in the world, the ALS provides unprecedented opportunities for research in science and technology not possible anywhere else. This year marked the beginning of operations and the start of the user research program at the ALS, which has already produced numerous high quality results. A national user facility located at Lawrence Berkeley Laboratory of the University of California, the ALS is available to researchers from academia, industry, and government laboratories. This report contains the following: (1) director`s message; (2) operations overview; (3) user program; (4) users` executive committee; (5) industrial outreach; (6) accelerator operations; (7) beamline control system; (8) insertion devices; (9) experimental systems; (10) beamline engineering; (11) first results from user beamlines; (12) beamlines for 1994--1995; (13) special events; (14) publications; (15) advisory panels; and (16) ALS staff.

  15. Ultraviolet Light Source Using Electrodeless Microwave Discharge

    NASA Astrophysics Data System (ADS)

    Nishikawa, Taku; Toyoda, Hirotaka

    2015-09-01

    Surface treatment technologies using ultraviolet (UV) light, such as organic residue removal, surface modification or sterilization, are widely used. So far, UV lamps using DC discharge with electrodes inside the lamp tube is commonly used. However, sputtering of electrode materials sometimes causes deposition on the inner tube surface as well as degradation of the electrodes, resulting in short life time of the lamp tube. In this study, we propose an electrodeless UV mercury (Hg) lamp source using microwave power. 2.45 GHz Microwave power (<4 kW) from a power supply is divided into four power lines using branch waveguides. A mercury lamp tube (diameter: 9.6 mm, length: 42 cm, Hg: 13.5 mg, Ar: 1 Torr) is inserted into the branch waveguides and microwave power is coupled to the plasma. Emission from the lamp is monitored by a monochromator and an 254 nm UV monitor. Lamp temperature is also measured by a thermography camera and tube temperature up to 900 K with good uniformity along ~ 30 cm was observed. Uniformity of the 254 nm UV light intensity was +15 % along the lamp tube. The maximum UV light intensity of 64 mW/cm2 was observed at a microwave power of 4 kW.

  16. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2011-05-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  17. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2010-12-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  18. Recent Developments in Impact and Application to Future Light Sources

    SciTech Connect

    Pogorelov, I.; Qiang, J.; Ryne, R.; Venturini, M.; Zholents, A.; Warnock, R.; /SLAC

    2008-02-13

    This paper discusses two recently added capabilities of the IMPACT suite that are relevant to modeling electron linacs, namely the new 1D coherent synchrotron radiation (CSR) modeling capability and the integrated Green's function (IFG) algorithm for modeling high aspect ratio beams. In addition, we present initial results of application of the enhanced version of IMPACT-Z to high-fidelity modeling of the microbunching instability in a realistic light source lattice.

  19. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    NASA Astrophysics Data System (ADS)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from

  20. NATIONAL SYNCHROTRON LIGHT SOURCE ACTIVITY REPORT 1998.

    SciTech Connect

    ROTHMAN,E.

    1999-05-01

    thereafter for half of the running time in FY 1998. In combination with the development of narrow gap undulators this mode opens the possibility of new undulators which could produce hard X-rays in the fundamental, perhaps up to 10 keV. On 27 September 1998, a low horizontal emittance lattice became operational at 2.584 GeV. This results in approximately a 50% decrease in the horizontal beam-size on dipole bending magnet beamlines, and somewhat less of a decrease on the insertion device lines. The beam lifetime is not degraded by the low emittance lattice. This represents an important achievement, enhancing for all users the x-ray ring brightness. The reduced horizontal emittance electron beam will produce brighter x-ray beams for all the beamlines, both bending magnets and insertion devices, adding to other recent increases in the X-Ray ring brightness. During FY 1999 users will gain experience of the new running mode and plans are in place to do the same at 2.8GeV during further studies sessions. Independent evidence of the reduced emittance is shown in Figure 2. This is a pinhole camera scan showing the X-ray beam profile, obtained on the diagnostic beamline X28. Finally, work has begun to update and refine the proposal of the Phase III upgrade endorsed by the Birgeneau panel and BESAC last year. With the whole NSLS facility in teenage years and with many demonstrated enhancements available, the time has come to herald in the next stage of life at the Light Source.

  1. Ptychographic nanotomography at the Swiss Light Source

    NASA Astrophysics Data System (ADS)

    Guizar-Sicairos, Manuel; Holler, Mirko; Diaz, Ana; da Silva, Julio C.; Tsai, Esther H. R.; Bunk, Oliver; Martinez-Perez, Carlos; Donoghue, Philip C. J.; Wellman, Charles H.; Menzel, Andreas

    2015-09-01

    Ptychography combines elements of scanning probe microscopy with coherent diffractive imaging and provides a robust high-resolution imaging technique. The extension of X-ray ptychography to 3D provides nanoscale maps with quantitative contrast of the sample complex-valued refractive index. We present here progress in reconstruction and post-processing algorithms for ptychographic nanotomography, as well as outline advances in the implementation and development of dedicated instrumentation for fast and precise 3D scanning at the Swiss Light Source. Compared to the first demonstration in 2010, such developments have allowed a dramatic improvement in resolution and measurement speed, with direct impact in the application of the technique for biology and materials science. We showcase the technique by detailing the measurement and reconstruction of a fossilized dispersed spore.

  2. Commissioning the Linac Coherent Light Source injector

    NASA Astrophysics Data System (ADS)

    Akre, R.; Dowell, D.; Emma, P.; Frisch, J.; Gilevich, S.; Hays, G.; Hering, Ph.; Iverson, R.; Limborg-Deprey, C.; Loos, H.; Miahnahri, A.; Schmerge, J.; Turner, J.; Welch, J.; White, W.; Wu, J.

    2008-03-01

    The Linac Coherent Light Source is a SASE x-ray free-electron laser (FEL) project presently under construction at SLAC [J. Arthur , SLAC-R-593, 2002.]. The injector section, from drive laser and rf photocathode gun through first bunch compressor chicane, was installed in the fall of 2006. The initial system commissioning with an electron beam was completed in August of 2007, with the goal of a 1.2-micron emittance in a 1-nC bunch demonstrated. The second phase of commissioning, including second bunch compressor and full linac, is planned for 2008, with FEL commissioning in 2009. We report experimental results and experience gained in the first phase of commissioning, including the photocathode drive laser, rf gun, photocathode, S-band and X-band rf systems, first bunch compressor, and the various beam diagnostics.

  3. ENERGY SOURCES AND LIGHT CURVES OF MACRONOVAE

    SciTech Connect

    Kisaka, Shota; Ioka, Kunihito; Takami, Hajime E-mail: takami@post.kek.jp

    2015-04-01

    A macronova (kilonova) was discovered with a short gamma-ray burst, GRB 130603B, which is widely believed to be powered by the radioactivity of r-process elements synthesized in the ejecta of a neutron star (NS)–binary merger. As an alternative, we propose that macronovae are energized by the central engine, i.e., a black hole or NS, and the injected energy is emitted after the adiabatic expansion of ejecta. This engine model is motivated by extended emission of short GRBs. In order to compare the theoretical models with observations, we develop analytical formulae for the light curves of macronovae. The engine model allows a wider parameter range, especially smaller ejecta mass, and a better fit to observations than the r-process model. Future observations of electromagnetic counterparts of gravitational waves should distinguish energy sources and constrain the activity of the central engine and the r-process nucleosynthesis.

  4. Energy Recovery Linacs for Light Source Applications

    SciTech Connect

    George Neil

    2011-04-01

    Energy Recovery Linacs are being considered for applications in present and future light sources. ERLs take advantage of the continuous operation of superconducting rf cavities to accelerate high average current beams with low losses. The electrons can be directed through bends, undulators, and wigglers for high brightness x ray production. They are then decelerated to low energy, recovering power so as to minimize the required rf drive and electrical draw. When this approach is coupled with advanced continuous wave injectors, very high power, ultra-short electron pulse trains of very high brightness can be achieved. This paper will review the status of worldwide programs and discuss the technology challenges to provide such beams for photon production.

  5. The Linac Cooherent Light Source (LCLS) Accelerator

    SciTech Connect

    Wu, Juhao; Emma, P.; /SLAC

    2007-03-21

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

  6. LED intense headband light source for fingerprint analysis

    DOEpatents

    Villa-Aleman, Eliel

    2005-03-08

    A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.

  7. Diamond Light Source: status and perspectives

    PubMed Central

    Materlik, Gerhard; Rayment, Trevor; Stuart, David I.

    2015-01-01

    Diamond Light Source, a third-generation synchrotron radiation (SR) facility in the UK, celebrated its 10th anniversary in 2012. A private limited company was set up in April 2002 to plan, construct and operate the new user-oriented SR facility, called in brief Diamond. It succeeded the Synchrotron Radiation Source in Daresbury, a second-generation synchrotron that opened in 1980 as the world's first dedicated X-ray-providing facility, closing finally in 2008, by which time Diamond's accelerators and first beamlines were operating and user experiments were under way. This theme issue of Philosophical Transactions of the Royal Society A gives some examples of the rich diversity of research done in the initial five years, with some glimpses of activity up to 2014. Speakers at the 10 year anniversary symposium were drawn from a small number of major thematic areas and each theme was elaborated by a few speakers whose contributions were placed into a broader context by a leading member of the UK academic community in the role of rapporteur. This introduction gives a summary of the design choices and strategic planning of Diamond as a coherent user facility, a snapshot of its present status and some consideration of future perspectives. PMID:25624517

  8. Status of the Metrology Light Source

    SciTech Connect

    Klein, R.; Ulm, G.; Feikes, J.; Hartrott, M. von; Wuestefeld, G.

    2010-06-23

    The Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute, has set up the low-energy electron storage ring Metrology Light Source (MLS) in close cooperation with the Helmholtz-Zentrum Berlin (HZB, formerly BESSY). This new storage ring has been in regular user operation since April 2008 and is dedicated to synchrotron-radiation-based metrology and technological developments in the far-IR/THz, IR, UV, VUV and EUV spectral range. The MLS has a double-bend-achromate lattice structure, injection is from a 105 MeV racetrack microtron. The electron energy can be ramped to any value from 105 MeV up to 630 MeV and the electron beam current covers the range from one stored electron (1 pA) up to 200 mA. The MLS is the first electron storage ring optimized for the generation of coherent synchrotron radiation, based on an electron bunch shortening mode. In this mode, MLS delivers coherent radiation in the far-IR/THz spectral range with enhanced intensity as compared to the normal mode of operation. Several beamlines are in operation or in construction, including one undulator beamline, bending magnet beamlines for the calibration of radiation sources and detectors and for reflectometry, an EUV metrology beamline and three IR/THz beamlines.

  9. The 4th Generation Light Source at Jefferson Lab

    SciTech Connect

    Stephen Benson; George Biallas; James Boyce; Donald Bullard; James Coleman; David Douglas; H. Dylla; Richard Evans; Pavel Evtushenko; Albert Grippo; Christopher Gould; Joseph Gubeli; David Hardy; Carlos Hernandez-Garcia; Kevin Jordan; John Klopf; Steven Moore; George Neil; Thomas Powers; Joseph Preble; Daniel Sexton; Michelle D. Shinn; Christopher Tennant; Richard Walker; Shukui Zhang; Gwyn Williams

    2007-04-25

    A number of "Grand Challenges" in Science have recently been identified in reports from The National Academy of Sciences, and the U.S. Dept. of Energy, Basic Energy Sciences. Many of these require a new generation of linac-based light source to study dynamical and non-linear phenomena in nanoscale samples. In this paper we present a summary of the properties of such light sources, comparing them with existing sources, and then describing in more detail a specific source at Jefferson Lab. Importantly, the JLab light source has developed some novel technology which is a critical enabler for other new light sources.

  10. The Sun: the Earth light source

    NASA Astrophysics Data System (ADS)

    Berrilli, Francesco; Giovannelli, Luca; Del Moro, Dario; Piazzesi, Roberto; Catena, Liu` Maria; Amicucci, Giordano; Vittorio, Nicola

    2015-04-01

    We have implemented at Department of Physics of University of Rome Tor Vergata a project called "The Sun: the Earth light source". The project obtained the official endorsement from the IAU Executive Committee Working Group for the International Year of Light. The project, specifically designed for high school students, is focused on the "scientific" study of Sun light by means of a complete acquisition system based on "on the shelf" appropriately CMOS low-cost sensor with free control s/w and self-assembled telescopes. The project (hereafter stage) plan is based on a course of two weeks (60 hours in total). The course contains 20 hours of theoretical lectures, necessary to learn basics about Sun, optics, telescopes and image sensors, and 40 hours of laboratory. During the course, scientists and astronomers share with high schools students, work activities in real research laboratories. High schools teachers are intensely involved in the project. Their role is to share activities with university teachers and realize outreach actions in the home institutions. Simultaneously, they are introduced to innovative teaching methods and the project in this way is regarded as a professional development course. Sun light analysis and Sun-Earth connection through light are the main scientific topics of this project. The laboratory section of the stage is executed in two phases (weeks): First phase aims are the realization of a keplerian telescope and low-cost acquisition system. During this week students are introduced to astronomical techniques used to safety collect and acquire solar light; Second phase aims is the realization of a low-cost instrument to analyse sunlight extracting information about the solar spectrum, solar irradiance and Sun-Earth connection. The proposed stage has been already tested in Italy reached the fifth edition in 2014. Since 2010, the project has been a cornerstone outreach program of the University of Rome Tor Vergata, the Italian Ministry of

  11. Status Of The Synchrotron Light Source DELTA

    SciTech Connect

    Berges, U.; Friedl, J.; Hartmann, P.; Schirmer, D.; Schmidt, G.; Sternemann, C.; Tolan, M.; Weis, T.; Westphal, C.; Wille, K.

    2004-05-12

    The Dortmund Electron Accelerator DELTA, located at the University of Dortmund, changed its scope during the last years into a 1.5 GeV synchrotron light source. DELTA is now operated for 3000 h per year including 2000 h dedicated beam time for synchrotron radiation use and 1000 h for machine physics, optimization and maintenance. The status of the accelerator complex is presented together with the beam operation, the installation and commissioning of beamlines and insertion devices. To serve user demands of photon energies up to more than 10 keV a 5.3 T superconducting asymmetric multipole wiggler (SAW) with a critical energy of 7.9 keV has been installed serving three beamlines in the hard X-ray regime with also circular polarization. Two undulator beamlines for photon energies between 5 and 400 eV (U250) and between 55 and 1500 eV (U55) and several dipole beamlines up to 200 eV are under operation. The construction and operation of the different beamlines is done by various universities and laboratories in Nordrhein-Westfalen.

  12. Linac Coherent Light Source - Status and Prospects

    SciTech Connect

    Galayda, John N.; /SLAC

    2005-11-09

    The Linac Coherent Light Source (LCLS) Project will be an x-ray free-electron laser. It is intended to produce pulses of 800-8,000 eV photons. Each pulse, produced with a repetition frequency of up to 120 Hz, will provide >10{sup 12} photons within a duration of less than 200 femtoseconds. The project employs the last kilometer of the SLAC linac to provide a low-emittance electron beam in the energy range 4-14 GeV to a single undulator. Two experiment halls, located 100m and 350m from the undulator exit, will house six experiment stations for research in atomic/molecular physics, pump-probe dynamics of materials and chemical processes, x-ray imaging of clusters and complex molecules, and plasma physics. Engineering design activities began in 2003, and the project is to be completed in March 2009. The project design permits straightforward expansion of the LCLS to multiple undulators.

  13. Sensor/amplifier for weak light sources

    NASA Technical Reports Server (NTRS)

    Desmet, D. J.; Jason, A. J.; Parr, A. C.

    1980-01-01

    Light sensor/amplifier circuit detects weak light converts it into strong electrical signal in electrically noisy environment. Circuit is relatively simple and uses inexpensive, readily available components. Device is useful in such applications as fire detection and photographic processing.

  14. Matrix light and pixel light: optical system architecture and requirements to the light source

    NASA Astrophysics Data System (ADS)

    Spinger, Benno; Timinger, Andreas L.

    2015-09-01

    Modern Automotive headlamps enable improved functionality for more driving comfort and safety. Matrix or Pixel light headlamps are not restricted to either pure low beam functionality or pure high beam. Light in direction of oncoming traffic is selectively switched of, potential hazard can be marked via an isolated beam and the illumination on the road can even follow a bend. The optical architectures that enable these advanced functionalities are diverse. Electromechanical shutters and lens units moved by electric motors were the first ways to realize these systems. Switching multiple LED light sources is a more elegant and mechanically robust solution. While many basic functionalities can already be realized with a limited number of LEDs, an increasing number of pixels will lead to more driving comfort and better visibility. The required optical system needs not only to generate a desired beam distribution with a high angular dynamic, but also needs to guarantee minimal stray light and cross talk between the different pixels. The direct projection of the LED array via a lens is a simple but not very efficient optical system. We discuss different optical elements for pre-collimating the light with minimal cross talk and improved contrast between neighboring pixels. Depending on the selected optical system, we derive the basic light source requirements: luminance, surface area, contrast, flux and color homogeneity.

  15. Far-Infrared Beamline at the Canadian Light Source

    NASA Astrophysics Data System (ADS)

    Billinghurst, Brant E.; May, Tim E.

    2014-06-01

    The far-infrared beamline at the Canadian Light Source is a state of the art user facility, which offers significantly more far-infrared brightness than conventional globar sources. The infrared radiation is collected from a bending magnet through a 55 X 37 mrad2 port to a Bruker IFS 125 HR spectrometer, which is equipped with a nine compartment scanning arm, allowing it to achieve spectral resolution better than 0.001 cm-1. Currently the beamline can achieve signal to noise ratios up to 8 times that which can be achieved using a traditional thermal source. This talk will provide an overview of the the beamline, and the capabilities available to users, recent and planned improvements including the addition of a Glow Discharge cell and advances in Coherent Synchrotron Radiation. Furthermore, the process of acquiring access to the facility will be covered.

  16. National Synchrotron Light Source 2010 Activity Report

    SciTech Connect

    Rowe, M.; Snyder, K. J.

    2010-12-29

    This is a very exciting period for photon sciences at Brookhaven National Laboratory. It is also a time of unprecedented growth for the Photon Sciences Directorate, which operates the National Synchrotron Light Source (NSLS) and is constructing NSLS-II, both funded by the Department of Energy's Office of Science. Reflecting the quick pace of our activities, we chose the theme 'Discovery at Light Speed' for the directorate's 2010 annual report, a fiscal year bookended by October 2009 and September 2010. The year began with the news that NSLS users Venki Ramakrishnan of Cambridge University (also a former employee in Brookhaven's biology department) and Thomas A. Steitz of Yale University were sharing the 2009 Nobel Prize in Chemistry with Ada E. Yonath of the Weizmann Institute of Science. Every research project has the potential for accolades. In 2010, NSLS users and staff published close to 900 papers, with about 170 appearing in premiere journals. Those are impressive stats for a facility nearly three decades old, testament to the highly dedicated team keeping NSLS at peak performance and the high quality of its user community. Our NSLS users come from a worldwide community of scientists using photons, or light, to carry out research in energy and environmental sciences, physics, materials science, chemistry, biology and medicine. All are looking forward to the new capabilities enabled by NSLS-II, which will offer unprecedented resolution at the nanoscale. The new facility will produce x-rays more than 10,000 times brighter than the current NSLS and host a suite of sophisticated instruments for cutting-edge science. Some of the scientific discoveries we anticipate at NSLS-II will lead to major advances in alternative energy technologies, such as hydrogen and solar. These discoveries could pave the way to: (1) catalysts that split water with sunlight for hydrogen production; (2) materials that can reversibly store large quantities of electricity or hydrogen; (3

  17. Scanning white-light interferometry with a supercontinuum source.

    PubMed

    Kassamakov, Ivan; Hanhijärvi, Kalle; Abbadi, Imad; Aaltonen, Juha; Ludvigsen, Hanne; Haeggström, Edward

    2009-05-15

    A supercontinuum light source was incorporated into a custom-built scanning white-light interferometer. This light source based on a Nd:YAG pumped microstructured optical fiber exhibits 1.21+/-0.10 microm temporal coherence length. The device operation was validated by characterizing the step height on a microelectromechanical system component. The measured step height- 7.027+/-0.020 microm-agreed with results obtained by employing traditional light sources: a halogen lamp and a white light-emitting diode. The new light source features high output intensity of 20-35 mW, which is beneficial when measuring low-reflectivity samples. As the supercontinuum light source may be modulated at frequencies exceeding 10 MHz, it holds potential for stroboscopic dynamic measurements.

  18. Filter selection based on light source for multispectral imaging

    NASA Astrophysics Data System (ADS)

    Xu, Peng; Xu, Haisong

    2016-07-01

    In multispectral imaging, it is necessary to select a reduced number of filters to balance the imaging efficiency and spectral reflectance recovery accuracy. Due to the combined effect of filters and light source on reflectance recovery, the optimal filters are influenced by the employed light source in the multispectral imaging system. By casting the filter selection as an optimization issue, the selection of optimal filters corresponding to the employed light source proceeds with respect to a set of target samples utilizing one kind of genetic algorithms, regardless of the detailed spectral characteristics of the light source, filters, and sensor. Under three light sources with distinct spectral power distributions, the proposed filter selection method was evaluated on a filter-wheel based multispectral device with a set of interference filters. It was verified that the filters derived by the proposed method achieve better spectral and colorimetric accuracy of reflectance recovery than the conventional one under different light sources.

  19. LED light source used in cultural relic illumination

    NASA Astrophysics Data System (ADS)

    Jin, Shangzhong; Zhang, Zaixuan; Zhou, Wen

    2002-09-01

    A new light source was researched and designed for cultural relic illumination. It is composed of high bright red, green, yellow, bule and white LED. A cone axes ellipse reflector is used in order to utilize light energy of LED as early possible. The light transmits in optical fiber bundle and lights the cultural relic in different angles and directions. The spectrum of the whole light source system is from 410nm to 700nm. There are not IR and UV. The light illuminance is 301x. Lighting of LEDs is controlled by rectangle waveform constant current source to make temperature lower and efficiency of light higher. Noise is avoided because a wind-cooling device is not used. Spectrum energy of different color light can be adjusted easily in order to show the important point of cultural relic.

  20. A slim apparatus of transferring discrete LEDs' light into an ultra-collimated planar light source.

    PubMed

    Teng, Tun-Chien; Sun, Wen-Shing; Tseng, Li-Wei; Chang, Wei-Chung

    2013-11-01

    In this paper, we proposed a novel apparatus, which has very slim volume and can transfer light emitted from discrete LEDs into a uniform and ultra-collimated planar light source (UCPLS). This apparatus adopts the two-layer folded frame and two-stage CPC design so that thickness of the entire apparatus can be minimized; especially the feeder in the two-stage CPC design can greatly reduce the thickness of the CPC and make the light passing through the second-stage CPC become much more collimated. In addition, by side-by-side arrangement, a large-sized UCPLS can also be obtained. In our embodiment with an emitting area of the upper LGP of 280 mmX80 mm and a LED with optical flux of 8 lumens used as the light source, the performance according to the related simulation results shows as follows: angular FWHM of the resultant light emitted from the apparatus in the vertical and horizontal is 4.87 degrees and 24 degrees, respectively; spatial uniformity and total energy efficiency reach 84% and 69%, respectively; the average head-on luminance reaches up 5600 nit, yet this apparatus consumes just 60 mW. Furthermore, the results also demonstrate this design has potential to be applied to the product of 23 inches above while thickness of the entire apparatus is only 2.2 mm. PMID:24216920

  1. Spectral confocal reflection microscopy using a white light source

    NASA Astrophysics Data System (ADS)

    Booth, M.; Juškaitis, R.; Wilson, T.

    2008-08-01

    We present a reflection confocal microscope incorporating a white light supercontinuum source and spectral detection. The microscope provides images resolved spatially in three-dimensions, in addition to spectral resolution covering the wavelength range 450-650nm. Images and reflection spectra of artificial and natural specimens are presented, showing features that are not normally revealed in conventional microscopes or confocal microscopes using discrete line lasers. The specimens include thin film structures on semiconductor chips, iridescent structures in Papilio blumei butterfly scales, nacre from abalone shells and opal gemstones. Quantitative size and refractive index measurements of transparent beads are derived from spectral interference bands.

  2. Light absorption by biomass burning source emissions

    NASA Astrophysics Data System (ADS)

    Cheng, Yuan; Engling, Guenter; Moosmüller, Hans; Arnott, W. Patrick; Chen, L.-W. Antony; Wold, Cyle E.; Hao, Wei Min; He, Ke-bin

    2016-02-01

    Black carbon (BC) aerosol has relatively short atmospheric lifetimes yet plays a unique and important role in the Earth's climate system, making it an important short-term climate mitigation target. Globally, biomass burning is the largest source of BC emissions into the atmosphere. This study investigated the mass absorption efficiency (MAE) of biomass burning BC generated by controlled combustion of various wildland fuels during the Fire Laboratory at Missoula Experiments (FLAME). MAE values derived from a photoacoustic spectrometer (∼7.8 m2/g at a wavelength of 532 nm) were in good agreement with those suggested for uncoated BC when the emission ratios of organic carbon (OC) to elemental carbon (EC) were extremely low (i.e., below 0.3). With the increase of OC/EC, two distinct types of biomass smoke were identified. For the first type, MAE exhibited a positive dependence on OC/EC, while the overestimation of the light absorption coefficient (babs) by a filter-based method was less significant and could be estimated by a nearly constant correction factor. For the second type, MAE was biased low and correlated negatively with OC/EC, while the overestimation of babs by the filter-based method was much more significant and showed an apparent OC/EC dependence. This study suggests that BC emission factors determined by the commonly used thermal-optical methods might be sustantially overestimated for some types of biomass burning emissions. Our results also indicate that biomass burning emissions may include some liquid-like organics that can significantly bias filter-based babs measurements.

  3. Achromatic lattice comparison for light sources

    SciTech Connect

    Kramer, S.L.; Crosbie, E.A.; Cho, Y.

    1988-01-01

    The next generation of synchrotron light sources are being designed to support a large number of undulators and require long dispersion-free insertion regions. With less demand for radiation from the dipole magnets, the storage ring cost per undulator beam can be reduced by decreasing the number of dipole magnets and increasing the number of dispersion free straight sections. The two simplest achromatic lattices are the Chasman-Green or double-bend achromatic (DBA) and the three-bend achromat (TBA). The DBA in its simplest form consists of a single horizontally-focussing quadrupole between the two dipole magnets. Since this quadrupole strength is fixed by the achromatic condition, the natural emittance (/var epsilon//sub n/) may vary as the beta functions in the insertion region (IR) are varied. The expanded Chasman-Green (also DBA) uses multiple quadrupoles in the dispersive section to provide emittance control independent of the beta functions in the IR. Although this provides flexibility in the ID beta functions, the horizontal phase advance is constrained to /phi/ /approx equal/ 180/degree/ between approximately the centers of the dipole magnets. If small /var epsilon//sub n/ is required, the horizontal phase advance between the dipoles will be near one and the lattice properties will be dominated by this systematic resonance. The TBA lattice places a third dipole between the DBA dipoles, eliminating the 180/degree/ horizontal phase advance constraint. However, the requirement of small /var epsilon//sub n/ limits the range of tune, since /mu//sub x/ /approx equal/ 1.29 in the dipoles alone for /var epsilon//sub n/ near its minimum value. The minimum emittance is five times smaller for the TBA than for the DBA with the same number of periods and, therefore, its phase advance can be relaxed more than the DBA for the same natural emittance. 5 refs., 4 figs., 1 tab.

  4. Inorganic volumetric light source excited by ultraviolet light

    DOEpatents

    Reed, S.; Walko, R.J.; Ashley, C.S.; Brinker, C.J.

    1994-04-26

    The invention relates to a composition for the volumetric generation of radiation. The composition comprises a porous substrate loaded with a component capable of emitting radiation upon interaction with an exciting radiation. Preferably, the composition is an aerogel substrate loaded with a component, e.g., a phosphor, capable of interacting with exciting radiation of a first energy, e.g., ultraviolet light, to produce radiation of a second energy, e.g., visible light. 4 figures.

  5. Inorganic volumetric light source excited by ultraviolet light

    DOEpatents

    Reed, Scott; Walko, Robert J.; Ashley, Carol S.; Brinker, C. Jeffrey

    1994-01-01

    The invention relates to a composition for the volumetric generation of radiation. The composition comprises a porous substrate loaded with a component capable of emitting radiation upon interaction with an exciting radiation. Preferably, the composition is an aerogel substrate loaded with a component, e.g., a phosphor, capable of interacting with exciting radiation of a first energy, e.g., ultraviolet light, to produce radiation of a second energy, e.g., visible light.

  6. Monolithic LED arrays, next generation smart lighting sources

    NASA Astrophysics Data System (ADS)

    Lagrange, Alexandre; Bono, Hubert; Templier, François

    2016-03-01

    LED have become the main light sources of the future as they open the path for intelligent use of light in time, intensity and color. In many usages, strong energy economy is done by adjusting these properties. The smart lighting has three dimensions, energy efficiency brought by GaN blue emitting LEDs, integration of electronics, sensors, microprocessors in the lighting system and development of new functionalities and services provided by the light. Monolithic LED arrays allow two major innovations, the spatial control of light emission and the adjustment of the electrical properties of the source.

  7. Barium light source method and apparatus

    NASA Technical Reports Server (NTRS)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  8. Uv-Light Stabilization Additive Package For Solar Cell Module And Laminated Glass Applications

    DOEpatents

    Hanoka, Jack I.; Klemchuk, Peter P.

    2002-03-05

    An ultraviolet light stabilization additive package is used in an encapsulant material that may be used in solar cell modules, laminated glass and a variety of other applications. The ultraviolet light stabilization additive package comprises a first hindered amine light stabilizer and a second hindered amine light stabilizer. The first hindered amine light stabilizer provides thermal oxidative stabilization, and the second hindered amine light stabilizer providing photo-oxidative stabilization.

  9. Phosphor-Free Solid State Light Sources

    SciTech Connect

    Nause, Jeff E; Ferguson, Ian; Doolittle, Alan

    2007-02-28

    The objective of this work was to demonstrate a light emitting diode that emitted white light without the aid of a phosphor. The device was based on the combination of a nitride LED and a fluorescing ZnO substrate. The early portion of the work focused on the growth of ZnO in undoped and doped form. The doped ZnO was successfully engineered to emit light at specific wavelengths by incorporating various dopants into the crystalline lattice. Thereafter, the focus of the work shifted to the epitaxial growth of nitride structures on ZnO. Initially, the epitaxy was accomplished with molecular beam epitaxy (MBE). Later in the program, metallorganic chemical vapor deposition (MOCVD) was successfully used to grow nitrides on ZnO. By combining the characteristics of the doped ZnO substrate with epitaxially grown nitride LED structures, a phosphor-free white light emitting diode was successfully demonstrated and characterized.

  10. Perception of light source distance from shading patterns.

    PubMed

    Schütt, Heiko H; Baier, Franziska; Fleming, Roland W

    2016-01-01

    Varying the distance of a light source from an object alters both the intensity and spatial distribution of surface shading patterns. We tested whether observers can use such cues to infer light source distance. Participants viewed stereoscopic renderings of rough objects with diffuse and glossy surfaces, which were illuminated by a point source at a range of distances. In one task, they adjusted the position of a small probe dot in three dimensions to report the apparent location of the light in the scene. In a second task, they adjusted the shading on one object (by moving an invisible light source) until it appeared to be illuminated from the same distance as another object. Participants' responses increased linearly with the true light source distance, suggesting that they have clear intuitions about how light source distance affects shading patterns for a variety of different surfaces. However, there were also systematic errors: Subjects overestimated light source distance in the probe adjustment task, and in both experiments, roughness and glossiness affected responses. We find the pattern of results is predicted surprisingly well by a simplistic model based only on the area of the image that exceeds a certain intensity threshold. Thus, although subjects can report light source distance, they may rely on simple--sometimes erroneous--heuristics to do so. PMID:26868887

  11. Perception of light source distance from shading patterns.

    PubMed

    Schütt, Heiko H; Baier, Franziska; Fleming, Roland W

    2016-01-01

    Varying the distance of a light source from an object alters both the intensity and spatial distribution of surface shading patterns. We tested whether observers can use such cues to infer light source distance. Participants viewed stereoscopic renderings of rough objects with diffuse and glossy surfaces, which were illuminated by a point source at a range of distances. In one task, they adjusted the position of a small probe dot in three dimensions to report the apparent location of the light in the scene. In a second task, they adjusted the shading on one object (by moving an invisible light source) until it appeared to be illuminated from the same distance as another object. Participants' responses increased linearly with the true light source distance, suggesting that they have clear intuitions about how light source distance affects shading patterns for a variety of different surfaces. However, there were also systematic errors: Subjects overestimated light source distance in the probe adjustment task, and in both experiments, roughness and glossiness affected responses. We find the pattern of results is predicted surprisingly well by a simplistic model based only on the area of the image that exceeds a certain intensity threshold. Thus, although subjects can report light source distance, they may rely on simple--sometimes erroneous--heuristics to do so.

  12. LED-array light source for medical therapy

    NASA Astrophysics Data System (ADS)

    Schlager, Kenneth J.; Ignatius, Ronald W.

    1993-07-01

    Light emitting diode (LED) array light sources currently in development offer an alternative to laser light sources in a wide range of medical applications. Previously developed as light sources for research in photosynthesis in plant growth experimentation, LED arrays have produced an average continuous output of 4 - 6 watts at a wavelength of 660 nm. This output is equivalent to the terrestrially sensed output of the sun at this wavelength at high noon. LED chips are arrayed on an alumina tile substrate that may be formed to provide optical power focused on a specified target area.

  13. Revised accident source terms for light-water reactors

    SciTech Connect

    Soffer, L.

    1995-02-01

    This paper presents revised accident source terms for light-water reactors incorporating the severe accident research insights gained in this area over the last 15 years. Current LWR reactor accident source terms used for licensing date from 1962 and are contained in Regulatory Guides 1.3 and 1.4. These specify that 100% of the core inventory of noble gases and 25% of the iodine fission products are assumed to be instantaneously available for release from the containment. The chemical form of the iodine fission products is also assumed to be predominantly elemental iodine. These assumptions have strongly affected present nuclear air cleaning requirements by emphasizing rapid actuation of spray systems and filtration systems optimized to retain elemental iodine. A proposed revision of reactor accident source terms and some im implications for nuclear air cleaning requirements was presented at the 22nd DOE/NRC Nuclear Air Cleaning Conference. A draft report was issued by the NRC for comment in July 1992. Extensive comments were received, with the most significant comments involving (a) release fractions for both volatile and non-volatile species in the early in-vessel release phase, (b) gap release fractions of the noble gases, iodine and cesium, and (c) the timing and duration for the release phases. The final source term report is expected to be issued in late 1994. Although the revised source terms are intended primarily for future plants, current nuclear power plants may request use of revised accident source term insights as well in licensing. This paper emphasizes additional information obtained since the 22nd Conference, including studies on fission product removal mechanisms, results obtained from improved severe accident code calculations and resolution of major comments, and their impact upon the revised accident source terms. Revised accident source terms for both BWRS and PWRS are presented.

  14. Synchrotron light sources: A powerful tool for science and technology

    SciTech Connect

    Schlachter, F.; Robinson, A.

    1996-01-01

    A new generation of synchrotron light sources is producing extremely bright beams of vacuum-ultraviolet and x-ray radiation, powerful new tools for research in a wide variety of basic and applied sciences. Spectromicroscopy using high spectral and spatial resolution is a new way of seeing, offering many opportunities in the study of matter. Development of a new light source provides the country or region of the world in which the light source is located many new opportunities: a focal point for research in many scientific and technological areas, a means of upgrading the technology infrastructure of the country, a means of training students, and a potential service to industry. A light source for Southeast Asia would thus be a major resource for many years. Scientists and engineers from light sources around the world look forward to providing assistance to make this a reality in Southeast Asia.

  15. UV emissions from low energy artificial light sources.

    PubMed

    Fenton, Leona; Moseley, Harry

    2014-01-01

    Energy efficient light sources have been introduced across Europe and many other countries world wide. The most common of these is the Compact Fluorescent Lamp (CFL), which has been shown to emit ultraviolet (UV) radiation. Light Emitting Diodes (LEDs) are an alternative technology that has minimal UV emissions. This brief review summarises the different energy efficient light sources available on the market and compares the UV levels and the subsequent effects on the skin of normal individuals and those who suffer from photodermatoses.

  16. Utraviolet Light Source in an Old Galaxy

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Hubble Space Telescope's exquisite resolution has allowed astronomers to resolve, for the first time, hot blue stars deep inside an elliptical galaxy. The swarm of nearly 8,000 blue stars resembles a blizzard of snowflakes near the core (lower right) of the neighboring galaxy M32, located 2.5 million light-years away in the constellation Andromeda. Hubble confirms that the ultraviolet light comes from a population of extremely hot helium-burning stars at a late stage in their lives. Unlike the Sun, which burns hydrogen into helium, these old stars exhausted their central hydrogen long ago, and now burn helium into heavier elements. The observations, taken in October 1998, were made with the camera mode of the Space Telescope Imaging Spectrograph (STIS) in ultraviolet light. The STIS field of view is only a small portion of the entire galaxy, which is 20 times wider on the sky. For reference, the full moon is 70 times wider than the STIS field-of-view. Thirty years ago, the first ultraviolet observations of elliptical galaxies showed that they were surprisingly bright when viewed in ultraviolet light. Before those pioneering UV observations, old groups of stars were assumed to be relatively cool and thus extremely faint in the ultraviolet. Over the years since the initial discovery of this unexpected ultraviolet light, indirect evidence has accumulated that it originates in a population of old, but hot, helium-burning stars. Now Hubble provides the first direct visual evidence.

  17. A new storage-ring light source

    SciTech Connect

    Chao, Alex

    2015-06-01

    A recently proposed technique in storage ring accelerators is applied to provide potential high-power sources of photon radiation. The technique is based on the steady-state microbunching (SSMB) mechanism. As examples of this application, one may consider a high-power DUV photon source for research in atomic and molecular physics or a high-power EUV radiation source for industrial lithography. A less challenging proof-of-principle test to produce IR radiation using an existing storage ring is also considered.

  18. Cathodoluminescent Source of Intense White Light

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2007-01-01

    The device described exploits cathodoluminescence to generate intense light in the visible and near-infrared regions of the spectrum. In this device, the material to be excited to luminescence is a layer of quartz or alumina powder on an electrically conductive plate exposed to a low-pressure plasma discharge. The plate is electrically biased positively to collect electron current.

  19. Rapidly pulsed, high intensity, incoherent light source

    NASA Technical Reports Server (NTRS)

    Evans, J. C., Jr.; Brandhorst, H. W., Jr. (Inventor)

    1974-01-01

    A rapid pulsing, high intensity, incoherent light is produced by selectively energizing a plurality of discharge lamps with a triggering circuit. Each lamp is connected to a capacitor, and a power supply is electrically connected to all but one of the capacitors. This last named capacitor is electrically connected to a discharge lamp which is connected to the triggering circuit.

  20. An experiment on the color rendering of different light sources

    NASA Astrophysics Data System (ADS)

    Fumagalli, Simonetta; Bonanomi, Cristian; Rizzi, Alessandro

    2013-02-01

    The color rendering index (CRI) of a light source attempts to measure how much the color appearance of objects is preserved when they are illuminated by the given light source. This problem is of great importance for various industrial and scientific fields, such as lighting architecture, design, ergonomics, etc. Usually a light source is specified through the Correlated Color Temperature or CCT. However two (or more) light sources with the same CCT but different spectral power distribution can exist. Therefore color samples viewed under two light sources with equal CCTs can appear different. Hence, the need for a method to assess the quality of a given illuminant in relation to color. Recently CRI has had a renewed interest because of the new LED-based lighting systems. They usually have a color rendering index rather low, but good preservation of color appearance and a pleasant visual appearance (visual appeal). Various attempts to develop a new color rendering index have been done so far, but still research is working for a better one. This article describes an experiment performed by human observers concerning the appearance preservation of color under some light sources, comparing it with a range of available color rendering indices.

  1. A numerical experiment on light pollution from distant sources

    NASA Astrophysics Data System (ADS)

    Kocifaj, M.

    2011-08-01

    To predict the light pollution of the night-time sky realistically over any location or measuring point on the ground presents quite a difficult calculation task. Light pollution of the local atmosphere is caused by stray light, light loss or reflection of artificially illuminated ground objects or surfaces such as streets, advertisement boards or building interiors. Thus it depends on the size, shape, spatial distribution, radiative pattern and spectral characteristics of many neighbouring light sources. The actual state of the atmospheric environment and the orography of the surrounding terrain are also relevant. All of these factors together influence the spectral sky radiance/luminance in a complex manner. Knowledge of the directional behaviour of light pollution is especially important for the correct interpretation of astronomical observations. From a mathematical point of view, the light noise or veil luminance of a specific sky element is given by a superposition of scattered light beams. Theoretical models that simulate light pollution typically take into account all ground-based light sources, thus imposing great requirements on CPU and MEM. As shown in this paper, a contribution of distant sources to the light pollution might be essential under specific conditions of low turbidity and/or Garstang-like radiative patterns. To evaluate the convergence of the theoretical model, numerical experiments are made for different light sources, spectral bands and atmospheric conditions. It is shown that in the worst case the integration limit is approximately 100 km, but it can be significantly shortened for light sources with cosine-like radiative patterns.

  2. Measurement of the speed of light from extraterrestrial sources

    NASA Astrophysics Data System (ADS)

    Wu, Jingshown; Huang, Yen-Ru; Tsao, Hen-Wai; Lee, San-Liang; Chang, Shenq-Tsong; Tsay, Ho-Lin; Young, Hong-Tsu

    2015-09-01

    The conventional measurements of the speed of light were performed before the early twentieth century. Only few used extraterrestrial sources and got the result with large uncertainty. We design a transmitter to modulate the rays from the local infrared light source and the extraterrestrial sources simultaneously into pulses. Both are received by a distant receiver. We have the white light travelling exactly along the path of the starlight pulses for calibration. It is found that the travel times of Aldebaran and Capella pulses are longer than that of Vega pulses. The results indicate that the speeds of starlights are different.

  3. An improved light source for laser ranging

    NASA Technical Reports Server (NTRS)

    Hamal, Karel; Richardson, Martin

    1993-01-01

    The development of a new laser material, Cr-doped LiSAF, makes possible the development of a laser source for satellite ranging systems that is more superior in performance capabilities than current Nd:YAG-based laser sources. This new material offers the potential of shorter pulses and more preferable wavelengths (850 and 425 nm) than multiwavelength Nd:YAG systems, leading to superior ranging resolution and greater detection sensitivity. We are embarking on a feasibility study of a two-wavelength, mode-locked laser system based on Cr:LiSAF, providing shorter pulses for improved ranging resolution.

  4. Synchronization System for Next Generation Light Sources

    SciTech Connect

    Zavriyev, Anton

    2014-03-27

    An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

  5. Open-source products for a lighting experiment device.

    PubMed

    Gildea, Kevin M; Milburn, Nelda

    2014-12-01

    The capabilities of open-source software and microcontrollers were used to construct a device for controlled lighting experiments. The device was designed to ascertain whether individuals with certain color vision deficiencies were able to discriminate between the red and white lights in fielded systems on the basis of luminous intensity. The device provided the ability to control the timing and duration of light-emitting diode (LED) and incandescent light stimulus presentations, to present the experimental sequence and verbal instructions automatically, to adjust LED and incandescent luminous intensity, and to display LED and incandescent lights with various spectral emissions. The lighting device could easily be adapted for experiments involving flashing or timed presentations of colored lights, or the components could be expanded to study areas such as threshold light perception and visual alerting systems.

  6. A 1.5 GeV compact light source with superconducting bending magnets

    SciTech Connect

    Garren, A.A. ||; Cline, D.B.; Kolonko, J.J. |; Green, M.A.; Johnson, D.E.; Leung, E.M.; Madura, D.D.

    1995-05-01

    This paper describes the design of a compact electron synchrotron light source for producing X-rays for medical imaging, protein crystallography, nano-machining and other uses up to 35 keV. The source will provide synchrotron light from six 6.9 tesla superconducting 60{degree} bending magnet stations. In addition the ring, contains conventional quadrupoles and sextupoles. The light source has a circumference of 26 meters, which permits it to be located in a variety of industrial and medical facilities.

  7. Source apportionment of light absorbing WSOC in South Asian outflow

    NASA Astrophysics Data System (ADS)

    Bosch, Carme; Kirillova, Elena; Andersson, August; Kruså, Martin; Budhavant, Krishnakant; Tiwari, Suresh; Gustafsson, Örjan

    2013-04-01

    Carbonaceous aerosols (CA) formed over South Asia are of special concern for human health and regional climate impacts. Anthropogenic emissions forming CA are generally high throughout the region and particularly over the Indo-Gangetic Plain. The net effects of CA on radiative climate forcing are still uncertain. One of the components of CA is black carbon (BC), dominated by soot-like elemental carbon, a strong absorber of solar radiation. Another component is organic carbon (OC), traditionally considered as a light scattering particle. However, recent field studies have shown OC to absorb at lower wavelengths. Thus OC, in addition to BC, may also contribute to light absorption and have a positive direct radiative effect on climate. Light absorbing organic aerosol is usually termed brown carbon (BrC). A significant fraction of BrC is water-soluble, therefore its dissolution into clouds could result in absorbing droplets that affect the cloud absorption and thus contributing to the indirect aerosol climate effects. In this study, light absorption and δ13C + Δ14C isotopic measurements of WSOC were studied in fine aerosols (PM 2.5) at two sites during early pre-monsoon season. New Delhi, one of the most densely populated and industrialized urban megacities in South Asia, was chosen to represent a strong source and Maldives Climate Observatory at Hanimaadhoo (MCOH) was chosen as a regional receptor which in wintertime is located downwind of the Indian subcontinent. Sampling in Delhi was done from mid-February to mid-March 2011 and in MCOH during March 2012. WSOC concentrations were 12±4.5 and 0.71±0.30 μg m-3 in Delhi and MCOH respectively. Whereas in Delhi WSOC contributed 31±4% of total organic carbon, this contribution was slightly higher in MCOH (40±12%). Light absorption by WSOC exhibited strong wavelength (?) dependence. In Maldives, WSOC Absorption Ångström Exponent (AAE) was found to be 6.9±0.4 and Mass Absorption Efficiency (MAE) measured at 365 nm

  8. Interference of light from independent sources

    SciTech Connect

    Pegg, David T.

    2006-12-15

    We extend and generalize previous work on the interference of light from independent cavities that began with the suggestion of Pfleegor and Mandel [Phys. Rev. 159, 1084 (1967)] that their observed interference of laser beams should not be associated too closely with particular states of the beams but more with the detection process itself. In particular we examine how the detection of interference induces a nonrandom-phase difference between internal cavity states with initial random phases for a much broader range of such states than has previously been considered. We find that a subsequent interference measurement should give results consistent with the induced phase difference. The inclusion of more cavities in the interference measurements enables the construction in principle of a laboratory in the sense used by Aharonov and Susskind, made up of cavity fields that can serve as frames of phase reference. We also show reasonably simply how intrinsic phase coherence of a beam of light leaking from a single cavity arises for any internal cavity state, even a photon number state. Although the work presented here may have some implications for the current controversy over whether or not a typical laboratory laser produces a coherent state, it is not the purpose of this paper to enter this controversy; rather it is to examine the interesting quantum physics that arises for cavities with more general internal states.

  9. Lighting system combining daylight concentrators and an artificial source

    DOEpatents

    Bornstein, Jonathan G.; Friedman, Peter S.

    1985-01-01

    A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.

  10. Neon reduction program on Cymer ArF light sources

    NASA Astrophysics Data System (ADS)

    Kanawade, Dinesh; Roman, Yzzer; Cacouris, Ted; Thornes, Josh; O'Brien, Kevin

    2016-03-01

    In response to significant neon supply constraints, Cymer has responded with a multi-part plan to support its customers. Cymer's primary objective is to ensure that reliable system performance is maintained while minimizing gas consumption. Gas algorithms were optimized to ensure stable performance across all operating conditions. The Cymer neon support plan contains four elements: 1. Gas reduction program to reduce neon by >50% while maintaining existing performance levels and availability; 2. short-term containment solutions for immediate relief. 3. qualification of additional gas suppliers; and 4. long-term recycling/reclaim opportunity. The Cymer neon reduction program has shown excellent results as demonstrated through the comparison on standard gas use versus the new >50% reduced neon performance for ArF immersion light sources. Testing included stressful conditions such as repetition rate, duty cycle and energy target changes. No performance degradation has been observed over typical gas lives.

  11. Microhollow cathode discharge excimer light sources

    SciTech Connect

    El-Habachi, A.; Moselhy, M.; El-Dakroury, A.; Schoenbach, K.H.

    1999-07-01

    Microhollow Cathode discharges are non-equilibrium, high pressure, direct current discharges. By reducing the diameter of the cathode opening in a hollow cathode discharge geometry to values in the sub millimeter range the authors were able to operate discharges in argon and xenon in a direct current mode up to atmospheric pressure. They have shown that these discharges are intense source of xenon and argon excimer radiation peaking at wavelengths of 172 nm and 130 nm, respectively. Spatially resolved measurements of the excimer source in xenon have been performed. The source was found to be cylindrical along the axis of the electrodes. Its radius increases with current and decreases with pressure. Stacking the discharges, operating them in series, holds the promise for the generation of a laser medium with sufficient length to provide the required threshold gain for a dc excimer laser. Experimental studies of the gain of the plasma column in microhollow cathode discharges are underway. Excimer efficiencies, defined as the ratio of optical to electrical power, of 6% to 9% have been achieved. Further increase of the efficiency seems to be possible; according to the modeling results, efficiencies of 30% to 40% may be obtainable. The effect of various parameters such as electrode geometry, gas flow and pulsed versus cw operation on the excimer efficiency is being studied with the goal to optimize the discharge.

  12. Large area, surface discharge pumped, vacuum ultraviolet light source

    DOEpatents

    Sze, Robert C.; Quigley, Gerard P.

    1996-01-01

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source. A contamination-free VUV light source having a 225 cm.sup.2 emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm.sup.2 at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing.

  13. Large area, surface discharge pumped, vacuum ultraviolet light source

    DOEpatents

    Sze, R.C.; Quigley, G.P.

    1996-12-17

    Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source is disclosed. A contamination-free VUV light source having a 225 cm{sup 2} emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm{sup 2} at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing. 3 figs.

  14. Diffusion filter eliminates fringe effects of coherent laser light source

    NASA Technical Reports Server (NTRS)

    Olsasky, M. J.

    1970-01-01

    Diffusion filter comprised of small particles in colloidal suspension reduces the coherence of a laser beam used as a photographic light source. Interference patterns which obscure details in photographic film are eliminated, the intensity and collimation are moderately affected.

  15. 21 CFR 352.71 - Light source (solar simulator).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) DRUGS FOR HUMAN USE SUNSCREEN DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Testing Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a sunscreen...

  16. 21 CFR 352.71 - Light source (solar simulator).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) DRUGS FOR HUMAN USE SUNSCREEN DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Testing Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a sunscreen...

  17. 21 CFR 352.71 - Light source (solar simulator).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) DRUGS FOR HUMAN USE SUNSCREEN DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Testing Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a sunscreen...

  18. Status report on the Advanced Light Source control system

    SciTech Connect

    Magyary, S.; Chin, M.; Fahmie, M.; Lancaster, H.; Molinari, P.; Robb, A.; Timossi, C.; Young, J.

    1991-11-11

    This paper is a status report on the ADVANCED LIGHT SOURCE (ALS) control system. The current status, performance data, and future plans will be discussed. Manpower, scheduling, and costs issues are addressed.

  19. Light source for narrow and broadband coherent Raman scattering microspectroscopy.

    PubMed

    Brinkmann, Maximilian; Dobner, Sven; Fallnich, Carsten

    2015-12-01

    We present a light source that is well adapted to both narrow- and broadband coherent Raman scattering (CRS) methods. Based on a single oscillator, the light source delivers synchronized broadband pulses via supercontinuum generation and narrowband, frequency-tunable pulses via four-wave mixing in a photonic crystal fiber. Seeding the four-wave mixing with a spectrally filtered part of the supercontinuum yields high-pulse energies up to 8 nJ and the possibility of scanning a bandwidth of 2000  cm(-1) in 25 ms. All pulses are emitted with a repetition frequency of 1 MHz, which ensures efficient generation of CRS signals while avoiding significant damage of the samples. Consequently, the light source combines the performance of individual narrow- and broadband CRS light sources in one setup, thus enabling hyperspectral imaging and rapid single-resonance imaging in parallel. PMID:26625022

  20. Science and Technology of Future Light Sources

    SciTech Connect

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, Janos; Long, Danielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z. -X.; Schenoy, Gopal; Schoenlein, Bob; Shen, Qun; Stephenson, Brian; Stohr, Joachim; Zholents, Alexander

    2009-01-28

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  1. Science and Technology of Future Light Sources

    SciTech Connect

    Dierker,S.; Bergmann, U.; Corlett, J.; Dierker, S.; Falcone, R.; Galayda, J.; Gibson, M.; Hastings, J.; Hettel, B.; Hill, J.; Hussain, Z.; Kao, C.-C.; Kirx, J.; Long, G.; McCurdy, B.; Raubenheimer, T.; Sannibale, F.; Seeman, J.; Shen, Z.-X.; Shenoy, g.; Schoenlein, B.; Shen, Q.; Stephenson, B.; Stohr, J.; Zholents, A.

    2008-12-01

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects. The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  2. New Directions in X-Ray Light Sources

    SciTech Connect

    Falcone, Roger

    2008-07-18

    July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

  3. New Directions in X-Ray Light Sources

    ScienceCinema

    Falcone, Roger

    2016-07-12

    July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

  4. Survey, alignment, and beam stability at the Advanced Light Source

    SciTech Connect

    Krebs, G.F.

    1997-10-01

    This paper describes survey and alignment at the Lawrence Berkeley Laboratories Advanced Light Source (ALS) accelerators from 1993 to 1997. The ALS is a third generation light source requiring magnet alignment to within 150 microns. To accomplish this, a network of monuments was established and maintained. Monthly elevation surveys show the movement of the floor over time. Inclinometers have recently been employed to give real time information about magnet, vacuum tank and magnet girder motion in the ALS storage ring.

  5. Hyperspectral microscopy to identify foodborne bacteria with optimum lighting source

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Hyperspectral microscopy is an emerging technology for rapid detection of foodborne pathogenic bacteria. Since scattering spectral signatures from hyperspectral microscopic images (HMI) vary with lighting sources, it is important to select optimal lights. The objective of this study is to compare t...

  6. Solid state light source for wavelength multiplex 3D

    NASA Astrophysics Data System (ADS)

    Huang, Junejei

    2012-10-01

    A solid state light source provided for wavelength multiplex 3D Display is proposed. The system of solid state light source includes blue laser arrays of two wavelengths, a 2-ring phosphor wheel, a multi-band filter and a TIR prism. Green and red phosphors excited by blue lasers provide the original green and red lights of wide bandwidth. By passing through or reflected by a multi-band filter, two groups of green and red lights of narrow bandwidth for left or right eyes are selected. Blue lasers of two wavelengths also provide two blue lights for left and right eyes. Instead of using a second rotated narrow band filters that synchronized with the first phosphor wheel, a wheel having two rings coated with mirrors and phosphors is used to replace the synchronization existing in the conventional two wheels method. After passing the 2-ring wheel, the light source switches between two light paths that lead to be reflected or transmitting through the multiband filter. The multi-band filter can be disposed in a telecentric optical path to secure a high efficiency for the filter. A compact spectral multiplex light source is realized and can be directly attached to any existing optical engine.

  7. Advanced light source, User`s Handbook, Revision 1

    SciTech Connect

    1995-07-01

    The Advanced Light Source (ALS) is a national facility for scientific research and development located at the Lawrence Berkeley National Laboratory (LBNL) of the University of California. Its purpose is to generate beams of very bright light in the ultraviolet and soft x-ray regions of the spectrum. The facility is open to researchers from industry, universities, and government laboratories.

  8. Passivation of quartz for halogen-containing light sources

    DOEpatents

    Falkenstein, Zoran

    1999-01-01

    Lifetime of halogen containing VUV, UV, visible or IR light sources can be extended by passivating the quartz or glass gas containers with halogens prior to filling the quartz with the halogen and rare gas mixtures used to produce the light.

  9. Development and evaluation of a light-emitting diode endoscopic light source

    NASA Astrophysics Data System (ADS)

    Clancy, Neil T.; Li, Rui; Rogers, Kevin; Driscoll, Paul; Excel, Peter; Yandle, Ron; Hanna, George; Copner, Nigel; Elson, Daniel S.

    2012-03-01

    Light-emitting diode (LED) based endoscopic illumination devices have been shown to have several benefits over arclamp systems. LEDs are energy-efficient, small, durable, and inexpensive, however their use in endoscopy has been limited by the difficulty in efficiently coupling enough light into the endoscopic light cable. We have demonstrated a highly homogenised lightpipe LED light source that combines the light from four Luminus LEDs emitting in the red, green, blue and violet using innovative dichroics that maximise light throughput. The light source spectrally combines light from highly divergent incoherent sources that have a Lambertian intensity profile to provide illumination matched to the acceptance numerical aperture of a liquid light guide or fibre bundle. The LED light source was coupled to a standard laparoscope and performance parameters (power, luminance, colour temperature) compared to a xenon lamp. Although the total illuminance from the endoscope was lower, adjustment of the LEDs' relative intensities enabled contrast enhancement in biological tissue imaging. The LED light engine was also evaluated in a minimally invasive surgery (MIS) box trainer and in vivo during a porcine MIS procedure where it was used to generate 'narrowband' images. Future work using the violet LED could enable photodynamic diagnosis of bladder cancer.

  10. Modeling of non-Lambertian sources in lighting applications

    NASA Astrophysics Data System (ADS)

    Bennahmias, Mark; Arik, Engin; Yu, Kevin; Voloshenko, Dmitry; Chua, Kangbin; Pradhan, Ranjit; Forrester, Thomas; Jannson, Tomasz

    2007-09-01

    The photometric modeling of LEDs as generalized Lambertian sources (GL-Sources) is discussed. Non-Lambertian LED sources, with axial symmetry, have important real-world applications in general lighting. In particular, so-called generalized Lambertian sources, following a cosine to the nth power distribution (n>=1), can be used to describe the luminous output profiles from solid-state lighting devices like LEDs. For such sources, the knowledge of total power (in Lumens [Lms]), the knowledge of the output angular characteristics, as well as source area, is sufficient information to determine all other critical photometric quantities such as: maximum radiant intensity (in Candelas [Cd = Lm/Sr]) and maximum luminance (in nits [nts = Cd/m2]), as well as illuminance (in lux [lx = Lm/m2]). In this paper, we analyze this approach to modeling LEDs in terms of its applicability to real sources.

  11. Percolation model with an additional source of disorder

    NASA Astrophysics Data System (ADS)

    Kundu, Sumanta; Manna, S. S.

    2016-06-01

    The ranges of transmission of the mobiles in a mobile ad hoc network are not uniform in reality. They are affected by the temperature fluctuation in air, obstruction due to the solid objects, even the humidity difference in the environment, etc. How the varying range of transmission of the individual active elements affects the global connectivity in the network may be an important practical question to ask. Here a model of percolation phenomena, with an additional source of disorder, is introduced for a theoretical understanding of this problem. As in ordinary percolation, sites of a square lattice are occupied randomly with probability p . Each occupied site is then assigned a circular disk of random value R for its radius. A bond is defined to be occupied if and only if the radii R1 and R2 of the disks centered at the ends satisfy a certain predefined condition. In a very general formulation, one divides the R1-R2 plane into two regions by an arbitrary closed curve. One defines a point within one region as representing an occupied bond; otherwise it is a vacant bond. The study of three different rules under this general formulation indicates that the percolation threshold always varies continuously. This threshold has two limiting values, one is pc(sq) , the percolation threshold for the ordinary site percolation on the square lattice, and the other is unity. The approach of the percolation threshold to its limiting values are characterized by two exponents. In a special case, all lattice sites are occupied by disks of random radii R ∈{0 ,R0} and a percolation transition is observed with R0 as the control variable, similar to the site occupation probability.

  12. Percolation model with an additional source of disorder.

    PubMed

    Kundu, Sumanta; Manna, S S

    2016-06-01

    The ranges of transmission of the mobiles in a mobile ad hoc network are not uniform in reality. They are affected by the temperature fluctuation in air, obstruction due to the solid objects, even the humidity difference in the environment, etc. How the varying range of transmission of the individual active elements affects the global connectivity in the network may be an important practical question to ask. Here a model of percolation phenomena, with an additional source of disorder, is introduced for a theoretical understanding of this problem. As in ordinary percolation, sites of a square lattice are occupied randomly with probability p. Each occupied site is then assigned a circular disk of random value R for its radius. A bond is defined to be occupied if and only if the radii R_{1} and R_{2} of the disks centered at the ends satisfy a certain predefined condition. In a very general formulation, one divides the R_{1}-R_{2} plane into two regions by an arbitrary closed curve. One defines a point within one region as representing an occupied bond; otherwise it is a vacant bond. The study of three different rules under this general formulation indicates that the percolation threshold always varies continuously. This threshold has two limiting values, one is p_{c}(sq), the percolation threshold for the ordinary site percolation on the square lattice, and the other is unity. The approach of the percolation threshold to its limiting values are characterized by two exponents. In a special case, all lattice sites are occupied by disks of random radii R∈{0,R_{0}} and a percolation transition is observed with R_{0} as the control variable, similar to the site occupation probability.

  13. Percolation model with an additional source of disorder.

    PubMed

    Kundu, Sumanta; Manna, S S

    2016-06-01

    The ranges of transmission of the mobiles in a mobile ad hoc network are not uniform in reality. They are affected by the temperature fluctuation in air, obstruction due to the solid objects, even the humidity difference in the environment, etc. How the varying range of transmission of the individual active elements affects the global connectivity in the network may be an important practical question to ask. Here a model of percolation phenomena, with an additional source of disorder, is introduced for a theoretical understanding of this problem. As in ordinary percolation, sites of a square lattice are occupied randomly with probability p. Each occupied site is then assigned a circular disk of random value R for its radius. A bond is defined to be occupied if and only if the radii R_{1} and R_{2} of the disks centered at the ends satisfy a certain predefined condition. In a very general formulation, one divides the R_{1}-R_{2} plane into two regions by an arbitrary closed curve. One defines a point within one region as representing an occupied bond; otherwise it is a vacant bond. The study of three different rules under this general formulation indicates that the percolation threshold always varies continuously. This threshold has two limiting values, one is p_{c}(sq), the percolation threshold for the ordinary site percolation on the square lattice, and the other is unity. The approach of the percolation threshold to its limiting values are characterized by two exponents. In a special case, all lattice sites are occupied by disks of random radii R∈{0,R_{0}} and a percolation transition is observed with R_{0} as the control variable, similar to the site occupation probability. PMID:27415234

  14. National Synchrotron Light Source annual report 1991

    SciTech Connect

    Hulbert, S.L.; Lazarz, N.M.

    1992-04-01

    This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLS computer system.

  15. Superradiant light source for atmospheric remote sensing

    NASA Astrophysics Data System (ADS)

    Voronine, Dmitri; Traverso, Andrew; Sanchez-Gonzalez, Rodrigo; Yuan, Luqi; Grubb, Michael; Wang, Kai; Zheltikov, Alexei; Dogariu, Arthur; Michael, James; Miles, Richard; Rostovtsev, Yuri; Sautenkov, Vladimir; Sokolov, Alexei; North, Simon; Scully, Marlan

    2012-02-01

    We have studied coherent emission from ambient air and demonstrated efficient generation of laser-like beams directed both forward and backward with respect to a nanosecond ultraviolet pumping laser beam. The generated optical gain is a result of two-photon photolysis of atmospheric O2, followed by two-photon excitation of atomic oxygen. We have analyzed the temporal shapes of the emitted pulses and have thereby shown that a large atomic coherence may well be responsible for the observed temporal structures. Our results suggest that the emission process is coherence brightened in its nature, and is to be compared with ordinary lasing where atomic coherence remains small on the one hand and cooperative Dicke superradiance where atomic coherence is maximized on the other. The collective coherence in this process adds insight as to the optical emission physics. The present superradiant source holds promise for remote sensing techniques employing nonlinear spectroscopy.

  16. Light source employing laser-produced plasma

    SciTech Connect

    Tao, Yezheng; Tillack, Mark S

    2013-09-17

    A system and a method of generating radiation and/or particle emissions are disclosed. In at least some embodiments, the system includes at least one laser source that generates a first pulse and a second pulse in temporal succession, and a target, where the target (or at least a portion the target) becomes a plasma upon being exposed to the first pulse. The plasma expand after the exposure to the first pulse, the expanded plasma is then exposed to the second pulse, and at least one of a radiation emission and a particle emission occurs after the exposure to the second pulse. In at least some embodiments, the target is a solid piece of material, and/or a time period between the first and second pulses is less than 1 microsecond (e.g., 840 ns).

  17. A multi-source portable light emitting diode spectrofluorometer

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A portable luminescence spectrofluorometer weighing only 1.5 kg that uses multiple light emitting diodes (LEDs) as excitation sources was developed and evaluated. Excitation using a sequence of seven individual broad-band LED emission sources enabled the generation of excitation-emission spectra usi...

  18. LED light sources for head-up displays

    NASA Astrophysics Data System (ADS)

    Wanninger, Mario

    2005-02-01

    The concept of Head-Up Displays is simple: move the important information a driver needs to see up into their line of sight, so they don"t have to take their eyes off the road. A projected image appears to be floating freely over the hood, at a distance of approximately two meters. Mirrors direct light from an image-generating LCD to the windshield where it is superimposed with the driver"s field of view. The LCD is lit with an appropriate light source. Requirements like long lifetime, vibration resistance, thermal stability and high luminance make LED light sources ideal for use in the automotive industry. The paper discusses the principles of the optical system design of an LED light source for Head-Up Displays.

  19. Artificial algae algorithm with multi-light source for numerical optimization and applications.

    PubMed

    Uymaz, Sait Ali; Tezel, Gulay; Yel, Esra

    2015-12-01

    Artificial algae algorithm (AAA), which is one of the recently developed bio-inspired optimization algorithms, has been introduced by inspiration from living behaviors of microalgae. In AAA, the modification of the algal colonies, i.e. exploration and exploitation is provided with a helical movement. In this study, AAA was modified by implementing multi-light source movement and artificial algae algorithm with multi-light source (AAAML) version was established. In this new version, we propose the selection of a different light source for each dimension that is modified with the helical movement for stronger balance between exploration and exploitation. These light sources have been selected by tournament method and each light source are different from each other. This gives different solutions in the search space. The best of these three light sources provides orientation to the better region of search space. Furthermore, the diversity in the source space is obtained with the worst light source. In addition, the other light source improves the balance. To indicate the performance of AAA with new proposed operators (AAAML), experiments were performed on two different sets. Firstly, the performance of AAA and AAAML was evaluated on the IEEE-CEC'13 benchmark set. The second set was real-world optimization problems used in the IEEE-CEC'11. To verify the effectiveness and efficiency of the proposed algorithm, the results were compared with other state-of-the-art hybrid and modified algorithms. Experimental results showed that the multi-light source movement (MLS) increases the success of the AAA.

  20. EDITORIAL: Special Issue on advanced and emerging light sources Special Issue on advanced and emerging light sources

    NASA Astrophysics Data System (ADS)

    Haverlag, Marco; Kroesen, Gerrit; Ferguson, Ian

    2011-06-01

    The papers in this special issue of Journal of Physics D: Applied Physics (JPhysD) originate from the 12th International Symposium on the Science and Technology of Light Sources and the 3rd International Conference on White LEDs and Solid State Lighting, held 11-16 July 2010 at Eindhoven University. Abstracts of all papers presented at this combined conference were published in the Conference Proceedings LS-WLED 2010 by FAST-LS, edited by M Haverlag, G M W Kroesen and T Taguchi. Special issues of the previous three LS conferences have been well-cited and have proven to be an important source of information for the lighting community. The 2010 LS-Symposium was a combined conference with the White LED Conference in order to enhance the scope of this conference series towards new light source technologies such as LEDs and OLEDs, and this co-operation will be continued in the future. Given the faster technology development in these areas it was also decided to shorten the interval between conferences from three to two years. Well over 200 invited presentations, landmark presentations and poster contributions were presented at the 2010 LS-Symposium. The organizing committee have selected from these a number of outstanding contributions with a high technological content and invited the authors to submit a full paper in JPhysD. The criteria were that the work should not be a repetition of the work already published in the Proceedings, but should be new, complete, within the scope of JPhysD, and meeting the normal quality standards of this journal. After peer review a combined set of 18 papers is published in this JPhysD special issue. In addition, a number of lighting-application-orientated papers will be published in a special issue of Journal of Light & Visual Environment later in 2011. The papers in this special issue of JPhysD show that research in the science and technology of light sources still covers a broad set of subject areas which includes both 'classical

  1. Fifth-Generation Free-Electron Laser Light Sources

    SciTech Connect

    Pellegrini, Claudio

    2011-03-02

    During the past few years, the Linac Coherent Light Source (LCLS) and the Free-Electron Laser in Hamburg (FLASH) have demonstrated the outstanding capability of free-electron lasers (FELs) as sources of coherent radiation in the soft and hard x-ray region. The high intensity, tens of GW, short pulses (few to less than 100 femtoseconds, and the unique transverse coherence properties are opening a new window to study the structure and dynamics of atomic and molecular systems. The LCLS, FLASH, and the other FELs now under construction are only the beginning of the development of these light sources. The next generations will reach new levels of performance: terawatt, atto-second, ultra-small line-width, high repetition rate, full longitudinal and transverse coherence. These future developments and the R&D needed to successfully build and operate the next generation of FEL light sources will be discussed.

  2. Progress in III-nitride based white light sources

    NASA Astrophysics Data System (ADS)

    Gaska, Remis; Zukauskas, Arturas; Shur, Michael S.; Khan, Mohamed A.

    2002-11-01

    We review two complementary approaches to the development of white light solid-state sources. The first approach, which involves polychromatic LED modules, is targeted at advanced optimization of spectral power distribution in order to establish an optimal trade-off between luminous efficacy and color rendering. We apply a stochastic method of optimization of a white-light source that relies on additive color mixing of the emissions from colored primary LEDs. We present the results on optimized spectra for all-semiconductor lamps composed of four primary LEDs with the line widths typical of present AlGaInP and AlInGaN technologies. We point out the problem of the lack of efficient yellow-green (570 nm) emitters required for polychromatic lamps with four and more primary LEDs. The second approach is based on the development of AlInGaN-based UV emitters that can be tailored to directly excite different phosphors without sensitizers. AlInGaN materials system demonstrated potential for making UV LEDs with a high power and short wavelengths required for such applications. This has been achieved by using Strain Energy Band Engineering (SEBE) and Pulsed Atomic Epitaxy (PALE) techniques. SEBE relies on quaternary AlGaInN compounds for controlling strain and band offset and for producing UV emitters with improved device performance. PALE allows us to incorporate the required significant amount of indium (few percent) in AlGaN, since it can be performed at lower growth temperatures required for In incorporation. Further improvements in materials quality of AlInGaN layers with a high molar fraction of Al will be achieved by using bulk AlN substrates.

  3. Assessing the Performance of 5mm White LED Light Sources forDeveloping-Country Applications

    SciTech Connect

    Mills, Evan

    2007-05-03

    Some white light-emitting diode (LED) light sources haverecently attained levels of efficiency and cost that allow them tocompete with fluorescent lighting for off-grid applications in thedeveloping world. Additional attributes (optics, size, ruggedness, andservice life) make them potentially superior products. Enormousreductions in energy use and greenhouse-gas emissions are thus possible,and system costs can be much lower given the ability to downsize thecharging and energy storage components compared to a fluorescentstrategy. However, there is a high risk of "market-spoiling" if inferiorproducts are introduced and result in user dissatisfaction. Completesystems involve the integration of light sources and optics, energysupply, and energy storage. A natural starting point for evaluatingproduct quality is to focus on the individual light sources. This reportdescribes testing results for batches of 10 5mm white LEDs from 26manufacturers. Efficacies and color properties are presented.

  4. LED-based endoscopic light source for spectral imaging

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Favreau, Peter; Rich, Thomas C.; Leavesley, Silas J.

    2016-03-01

    Colorectal cancer is the United States 3rd leading cancer in death rates.1 The current screening for colorectal cancer is an endoscopic procedure using white light endoscopy (WLE). There are multiple new methods testing to replace WLE, for example narrow band imaging and autofluorescence imaging.2 However, these methods do not meet the need for a higher specificity or sensitivity. The goal for this project is to modify the presently used endoscope light source to house 16 narrow wavelength LEDs for spectral imaging in real time while increasing sensitivity and specificity. The process to do such was to take an Olympus CLK-4 light source, replace the light and electronics with 16 LEDs and new circuitry. This allows control of the power and intensity of the LEDs. This required a larger enclosure to house a bracket system for the solid light guide (lightpipe), three new circuit boards, a power source and National Instruments hardware/software for computer control. The results were a successfully designed retrofit with all the new features. The LED testing resulted in the ability to control each wavelength's intensity. The measured intensity over the voltage range will provide the information needed to couple the camera for imaging. Overall the project was successful; the modifications to the light source added the controllable LEDs. This brings the research one step closer to the main goal of spectral imaging for early detection of colorectal cancer. Future goals will be to connect the camera and test the imaging process.

  5. Inherent visible light signature of an intense underwater ultraviolet light source due to combined Raman and fluorescence effects

    NASA Astrophysics Data System (ADS)

    Mazel, Charles H.; Kalata-Olson, Jody; Pham, Chuong N.

    2000-07-01

    We investigated the utility of a portable, intense source of ultraviolet light for diver use in support of Very Shallow Water operations. The working hypothesis was that the light would be of use to divers at short-to-medium ranges (up to several meters) while remaining invisible to surface observers due to the incoherent insensitivity of the human eye to ultraviolet light. The light source contained an arc discharge lamp rich in short wavelengths and was fitted with a filter that transmitted only the near ultraviolet portion of the spectrum. In-water tests were made in darkness using Navy divers both in a natural coastal environment and in a test tank. It was found that the light was of limited utility to the divers. In addition, the light was not covert because of a bluish-white glow associated with the ultraviolet beam. Subsequent measurements demonstrated that the visible glow was produced by a combination of fluorescence of dissolved organic matter in the water and Raman scatter from the water itself. The relative importance of the two factors varied with water type. These two effects that transform light from the invisible to the visible impose inherent limitations on the use of ultraviolet light for covert operations.

  6. EDITORIAL: Special Issue on advanced and emerging light sources Special Issue on advanced and emerging light sources

    NASA Astrophysics Data System (ADS)

    Haverlag, Marco; Kroesen, Gerrit; Ferguson, Ian

    2011-06-01

    The papers in this special issue of Journal of Physics D: Applied Physics (JPhysD) originate from the 12th International Symposium on the Science and Technology of Light Sources and the 3rd International Conference on White LEDs and Solid State Lighting, held 11-16 July 2010 at Eindhoven University. Abstracts of all papers presented at this combined conference were published in the Conference Proceedings LS-WLED 2010 by FAST-LS, edited by M Haverlag, G M W Kroesen and T Taguchi. Special issues of the previous three LS conferences have been well-cited and have proven to be an important source of information for the lighting community. The 2010 LS-Symposium was a combined conference with the White LED Conference in order to enhance the scope of this conference series towards new light source technologies such as LEDs and OLEDs, and this co-operation will be continued in the future. Given the faster technology development in these areas it was also decided to shorten the interval between conferences from three to two years. Well over 200 invited presentations, landmark presentations and poster contributions were presented at the 2010 LS-Symposium. The organizing committee have selected from these a number of outstanding contributions with a high technological content and invited the authors to submit a full paper in JPhysD. The criteria were that the work should not be a repetition of the work already published in the Proceedings, but should be new, complete, within the scope of JPhysD, and meeting the normal quality standards of this journal. After peer review a combined set of 18 papers is published in this JPhysD special issue. In addition, a number of lighting-application-orientated papers will be published in a special issue of Journal of Light & Visual Environment later in 2011. The papers in this special issue of JPhysD show that research in the science and technology of light sources still covers a broad set of subject areas which includes both 'classical

  7. The Munich Compact Light Source: initial performance measures.

    PubMed

    Eggl, Elena; Dierolf, Martin; Achterhold, Klaus; Jud, Christoph; Günther, Benedikt; Braig, Eva; Gleich, Bernhard; Pfeiffer, Franz

    2016-09-01

    While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented. PMID:27577768

  8. The Munich Compact Light Source: initial performance measures.

    PubMed

    Eggl, Elena; Dierolf, Martin; Achterhold, Klaus; Jud, Christoph; Günther, Benedikt; Braig, Eva; Gleich, Bernhard; Pfeiffer, Franz

    2016-09-01

    While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hardening artifacts for imaging experiments. Over the last decade, compact synchrotron sources based on inverse Compton scattering have evolved as one of the most promising types of laboratory-scale X-ray sources: they provide a performance and brilliance that lie in between those of large-scale synchrotron sources and X-ray tube sources, with significantly reduced financial and spatial requirements. These sources produce X-rays through the collision of relativistic electrons with infrared laser photons. In this study, an analysis of the performance, such as X-ray flux, source size and spectra, of the first commercially sold compact light source, the Munich Compact Light Source, is presented.

  9. Suboptimal Light Conditions Influence Source-Sink Metabolism during Flowering

    PubMed Central

    Christiaens, Annelies; De Keyser, Ellen; Pauwels, Els; De Riek, Jan; Gobin, Bruno; Van Labeke, Marie-Christine

    2016-01-01

    Reliance on carbohydrates during flower forcing was investigated in one early and one late flowering cultivar of azalea (Rhododendron simsii hybrids). Carbohydrate accumulation, invertase activity, and expression of a purported sucrose synthase gene (RsSUS) was monitored during flower forcing under suboptimal (natural) and optimal (supplemental light) light conditions, after a cold treatment (7°C + dark) to break flower bud dormancy. Post-production sucrose metabolism and flowering quality was also assessed. Glucose and fructose concentrations and invertase activity increased in petals during flowering, while sucrose decreased. In suboptimal light conditions RsSUS expression in leaves increased as compared to optimal light conditions, indicating that plants in suboptimal light conditions have a strong demand for carbohydrates. However, carbohydrates in leaves were markedly lower in suboptimal light conditions compared to optimal light conditions. This resulted in poor flowering of plants in suboptimal light conditions. Post-production flowering relied on the stored leaf carbon, which could be accumulated under optimal light conditions in the greenhouse. These results show that flower opening in azalea relies on carbohydrates imported from leaves and is source-limiting under suboptimal light conditions. PMID:26973689

  10. Suboptimal Light Conditions Influence Source-Sink Metabolism during Flowering.

    PubMed

    Christiaens, Annelies; De Keyser, Ellen; Pauwels, Els; De Riek, Jan; Gobin, Bruno; Van Labeke, Marie-Christine

    2016-01-01

    Reliance on carbohydrates during flower forcing was investigated in one early and one late flowering cultivar of azalea (Rhododendron simsii hybrids). Carbohydrate accumulation, invertase activity, and expression of a purported sucrose synthase gene (RsSUS) was monitored during flower forcing under suboptimal (natural) and optimal (supplemental light) light conditions, after a cold treatment (7°C + dark) to break flower bud dormancy. Post-production sucrose metabolism and flowering quality was also assessed. Glucose and fructose concentrations and invertase activity increased in petals during flowering, while sucrose decreased. In suboptimal light conditions RsSUS expression in leaves increased as compared to optimal light conditions, indicating that plants in suboptimal light conditions have a strong demand for carbohydrates. However, carbohydrates in leaves were markedly lower in suboptimal light conditions compared to optimal light conditions. This resulted in poor flowering of plants in suboptimal light conditions. Post-production flowering relied on the stored leaf carbon, which could be accumulated under optimal light conditions in the greenhouse. These results show that flower opening in azalea relies on carbohydrates imported from leaves and is source-limiting under suboptimal light conditions. PMID:26973689

  11. Picosecond supercontinuum light source for stroboscopic white-light interferometry with freely adjustable pulse repetition rate.

    PubMed

    Novotny, Steffen; Durairaj, Vasuki; Shavrin, Igor; Lipiäinen, Lauri; Kokkonen, Kimmo; Kaivola, Matti; Ludvigsen, Hanne

    2014-06-01

    We present a picosecond supercontinuum light source designed for stroboscopic white-light interferometry. This source offers a potential for high-resolution characterization of vibrational fields in electromechanical components with frequencies up to the GHz range. The light source concept combines a gain-switched laser diode, the output of which is amplified in a two-stage fiber amplifier, with supercontinuum generation in a microstructured optical fiber. Implemented in our white-light interferometer setup, optical pulses with optimized spectral properties and below 310 ps duration are used for stroboscopic illumination at freely adjustable repetition rates. The performance of the source is demonstrated by characterizing the surface vibration field of a square-plate silicon MEMS resonator at 3.37 MHz. A minimum detectable vibration amplitude of less than 100 pm is reached.

  12. Theoretical investigation of a tunable free-electron light source

    SciTech Connect

    Liu Shenggang; Hu Min; Zhang Yaxin; Liu Weihao; Zhang Ping; Zhou Jun

    2011-06-15

    The concept and experimental results of a light source given in a recent paper by Adamo et al.[Phys. Rev. Lett. 103, 113901 (2009)] are very interesting and attractive. Our paper presents detailed theoretical investigations on such a light source, and our results confirm that the mechanism of the light radiation experimentally detected in the published paper is a special kind of diffraction radiation in a waveguide with nanoscale periodic structure excited by an electron beam. The numerical calculations based on our theory and digital simulations agree well with the experimental results. This mechanism of diffraction radiation is of significance in physics and optics, and may bring good opportunities for the generation of electromagnetic waves from terahertz to light frequency regimes.

  13. Electrodeless lighting RF power source development. Final report

    SciTech Connect

    1996-08-30

    An efficient, solid state RF power source has been developed on this NICE project for exciting low power electrodeless lamp bulbs. This project takes full advantage of concurrent advances in electrodeless lamp technology. Electrodeless lamp lighting systems utilizing the sulfur based bulb type developed by Fusion Lighting, Inc., is an emerging technology which is based on generating light in a confined plasma created and sustained by RF excitation. The bulb for such a lamp is filled with a particular element and inert gas at low pressure when cold. RF power from the RF source creates a plasma within the bulb which reaches temperatures approaching those of high pressure discharge lamp plasmas. At these temperatures the plasma radiates substantial visible light with a spectrum similar to sunlight.

  14. Data format standard for sharing light source measurements

    NASA Astrophysics Data System (ADS)

    Gregory, G. Groot; Ashdown, Ian; Brandenburg, Willi; Chabaud, Dominique; Dross, Oliver; Gangadhara, Sanjay; Garcia, Kevin; Gauvin, Michael; Hansen, Dirk; Haraguchi, Kei; Hasna, Günther; Jiao, Jianzhong; Kelley, Ryan; Koshel, John; Muschaweck, Julius

    2013-09-01

    Optical design requires accurate characterization of light sources for computer aided design (CAD) software. Various methods have been used to model sources, from accurate physical models to measurement of light output. It has become common practice for designers to include measured source data for design simulations. Typically, a measured source will contain rays which sample the output distribution of the source. The ray data must then be exported to various formats suitable for import into optical analysis or design software. Source manufacturers are also making measurements of their products and supplying CAD models along with ray data sets for designers. The increasing availability of data has been beneficial to the design community but has caused a large expansion in storage needs for the source manufacturers since each software program uses a unique format to describe the source distribution. In 2012, the Illuminating Engineering Society (IES) formed a working group to understand the data requirements for ray data and recommend a standard file format. The working group included representatives from software companies supplying the analysis and design tools, source measurement companies providing metrology, source manufacturers creating the data and users from the design community. Within one year the working group proposed a file format which was recently approved by the IES for publication as TM-25. This paper will discuss the process used to define the proposed format, highlight some of the significant decisions leading to the format and list the data to be included in the first version of the standard.

  15. Structural biology research at the National Synchroton Light Source

    SciTech Connect

    1996-05-01

    The world`s foremost facility for scientific research using x-rays and ultraviolet and infrared radiation is operated by the national synchrotron Light Source Department. This year alone, a total of 2200 guest researchers performed experiments at the world`s largest source of synchrotron light. Researchers are trying to define the three- dimensional structures of biological macromolecules to create a map of life, a guide for exploring the biological and chemical interactions of the vast variety of molecules found in living organisms. Studies in structural biology may lead to new insights into how biological systems are formed and nourished, how they survive and grow, how they are damaged and die. This document discusses some the the structural biological research done at the National Synchrotron Light Source.

  16. Tunable light source for use in photoacoustic spectrometers

    DOEpatents

    Bisson, Scott E.; Kulp, Thomas J.; Armstrong, Karla M.

    2005-12-13

    The present invention provides a photoacoustic spectrometer that is field portable and capable of speciating complex organic molecules in the gas phase. The spectrometer has a tunable light source that has the ability to resolve the fine structure of these molecules over a large wavelength range. The inventive light source includes an optical parametric oscillator (OPO) having combined fine and coarse tuning. By pumping the OPO with the output from a doped-fiber optical amplifier pumped by a diode seed laser, the inventive spectrometer is able to speciate mixtures having parts per billion of organic compounds, with a light source that has a high efficiency and small size, allowing for portability. In an alternative embodiment, the spectrometer is scanned by controlling the laser wavelength, thus resulting in an even more compact and efficient design.

  17. Collimating lens for light-emitting-diode light source based on non-imaging optics.

    PubMed

    Wang, Guangzhen; Wang, Lili; Li, Fuli; Zhang, Gongjian

    2012-04-10

    A collimating lens for a light-emitting-diode (LED) light source is an essential device widely used in lighting engineering. Lens surfaces are calculated by geometrical optics and nonimaging optics. This design progress does not rely on any software optimization and any complex iterative process. This method can be used for any type of light source not only Lambertian. The theoretical model is based on point source. But the practical LED source has a certain size. So in the simulation, an LED chip whose size is 1 mm*1 mm is used to verify the feasibility of the model. The mean results show that the lenses have a very compact structure and good collimating performance. Efficiency is defined as the ratio of the flux in the illuminated plane to the flux from LED source without considering the lens material transmission. Just investigating the loss in the designed lens surfaces, the two types of lenses have high efficiencies of more than 90% and 99%, respectively. Most lighting area (possessing 80% flux) radii are no more than 5 m when the illuminated plane is 200 m away from the light source. PMID:22505154

  18. Does the light source affect the repairability of composite resins?

    PubMed

    Karaman, Emel; Gönülol, Nihan

    2014-01-01

    The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin--Filtek Silorane, Filtek Z550 (3M ESPE), Gradia Direct Anterior (GC), and Aelite Posterior (BISCO)--were prepared and light-cured with a QTH light curing unit (LCU). The specimens were aged by thermal cycling and divided into three subgroups according to the light source used--QTH, LED, or PAC (n = 10). They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray). The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option. PMID:25098825

  19. Gallium Nitride Nanowires and Heterostructures: Toward Color-Tunable and White-Light Sources.

    PubMed

    Kuykendall, Tevye R; Schwartzberg, Adam M; Aloni, Shaul

    2015-10-14

    Gallium-nitride-based light-emitting diodes have enabled the commercialization of efficient solid-state lighting devices. Nonplanar nanomaterial architectures, such as nanowires and nanowire-based heterostructures, have the potential to significantly improve the performance of light-emitting devices through defect reduction, strain relaxation, and increased junction area. In addition, relaxation of internal strain caused by indium incorporation will facilitate pushing the emission wavelength into the red. This could eliminate inefficient phosphor conversion and enable color-tunable emission or white-light emission by combining blue, green, and red sources. Utilizing the waveguiding modes of the individual nanowires will further enhance light emission, and the properties of photonic structures formed by nanowire arrays can be implemented to improve light extraction. Recent advances in synthetic methods leading to better control over GaN and InGaN nanowire synthesis are described along with new concept devices leading to efficient white-light emission. PMID:26032973

  20. Gallium Nitride Nanowires and Heterostructures: Toward Color-Tunable and White-Light Sources.

    PubMed

    Kuykendall, Tevye R; Schwartzberg, Adam M; Aloni, Shaul

    2015-10-14

    Gallium-nitride-based light-emitting diodes have enabled the commercialization of efficient solid-state lighting devices. Nonplanar nanomaterial architectures, such as nanowires and nanowire-based heterostructures, have the potential to significantly improve the performance of light-emitting devices through defect reduction, strain relaxation, and increased junction area. In addition, relaxation of internal strain caused by indium incorporation will facilitate pushing the emission wavelength into the red. This could eliminate inefficient phosphor conversion and enable color-tunable emission or white-light emission by combining blue, green, and red sources. Utilizing the waveguiding modes of the individual nanowires will further enhance light emission, and the properties of photonic structures formed by nanowire arrays can be implemented to improve light extraction. Recent advances in synthetic methods leading to better control over GaN and InGaN nanowire synthesis are described along with new concept devices leading to efficient white-light emission.

  1. The Advanced Light Source (ALS) Radiation Safety System. Revised

    SciTech Connect

    Ritchie, A.L.; Oldfather, D.E.; Lindner, A.F.

    1993-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 Gev synchrotron light source facility consisting of a 120 kev electron gun, 50 Mev linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. Figure 1. ALS floor plan. Pairs of neutron and gamma radiation monitors are shown as dots numbered from 1 to 12. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies.

  2. Laser wakefield accelerator based light sources: potential applications and requirements

    SciTech Connect

    Albert, F.; Thomas, A. G.; Mangles, S. P.D.; Banerjee, S.; Corde, S.; Flacco, A.; Litos, M.; Neely, D.; Viera, J.; Najmudin, Z.; Bingham, R.; Joshi, C.; Katsouleas, T.

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  3. Design of Beamline BL9 at Saga Light Source

    SciTech Connect

    Tanaka, Tooru; Ogawa, Hiroshi; Kamada, Masao; Nishio, Mitsuhiro; Guo, Qixin; Masuda, Masataka; Motooka, Teruaki; Kondo, Yuzi; Hayashida, Kazuki; Yoshimura, Daisuke; Setoyama, Hiroyuki; Okajima, Toshihiro

    2007-01-19

    Saga Light Source (SAGA-LS), which has been constructed at Tosu city in Saga prefecture, is a compact synchrotron light source with storage electron energy of 1.4 GeV. A new beamline for the development of advanced materials and processing has been designed, and is now under construction at BL9 of SAGA-LS. This beamline is one of the three bending magnet beamlines (BL9, BL12, and BL15) constructed by Saga Prefectural Government. In this paper, we describe the design and the expected optical performance of the beamline BL9 at SAGA-LS.

  4. Electron-beam-pumped VCSEL light source for projection display

    NASA Astrophysics Data System (ADS)

    Tiberi, Michael D.; Kozlovsky, Vladimir I.

    2005-04-01

    An electron beam pumped vertical cavity laser, or an "eVCSEL", has been developed as a low-cost light source for LCOS and DLP based consumer television. 1000 lumens directed towards the spatial light modulator requires a total power of 144 watts for lasers in the three primary colors. This power surplus allows for high screen brightness for rear projection televisions of diagonals greater than 50 inches and eliminates the need for high gain screens with the benefit of larger viewing angles. Because of the high saturation of laser light, a color gamut approaching that of the human visual system is possible, creating superior image reproduction.

  5. Brazilian Synchrotron Light Source: current results and future perspectives

    NASA Astrophysics Data System (ADS)

    Roque da Silva, Antonio Jose

    2013-03-01

    The application of synchrotron radiation in a great variety of fields in general, and condensed matter in particular, has increased steadily worldwide. This, to a large extent, is a result of the availability of the much brighter third-generation light sources, which opened up new experimental techniques. Brazil gave an important contribution to science in Latin America through the development of the necessary technology and the construction of the first synchrotron in the southern hemisphere, still the only one in Latin America. The Laboratório Nacional de Luz Síncrotron - LNLS, operates this installation as an open facility since 1997, having today more than 1300 users yearly. Despite all this success, the current Brazilian light source is a second-generation machine, with relatively low electron energy, high emittance and few straight sections for insertion devices. LNLS is currently engaged in the design and construction of a new, third-generation synchrotron light source. It is being planned to be a state of the art machine, providing tools for cutting edge research that are non existent today in Brazil. In this talk an overview of the status of the current Brazilian light source will be provided, illustrated with some experimental results from users, as well as the future perspectives of the new synchrotron source.

  6. Applications of laser wakefield accelerator-based light sources

    NASA Astrophysics Data System (ADS)

    Albert, Félicie; Thomas, Alec G. R.

    2016-11-01

    Laser-wakefield accelerators (LWFAs) were proposed more than three decades ago, and while they promise to deliver compact, high energy particle accelerators, they will also provide the scientific community with novel light sources. In a LWFA, where an intense laser pulse focused onto a plasma forms an electromagnetic wave in its wake, electrons can be trapped and are now routinely accelerated to GeV energies. From terahertz radiation to gamma-rays, this article reviews light sources from relativistic electrons produced by LWFAs, and discusses their potential applications. Betatron motion, Compton scattering and undulators respectively produce x-rays or gamma-rays by oscillating relativistic electrons in the wakefield behind the laser pulse, a counter-propagating laser field, or a magnetic undulator. Other LWFA-based light sources include bremsstrahlung and terahertz radiation. We first evaluate the performance of each of these light sources, and compare them with more conventional approaches, including radio frequency accelerators or other laser-driven sources. We have then identified applications, which we discuss in details, in a broad range of fields: medical and biological applications, military, defense and industrial applications, and condensed matter and high energy density science.

  7. The Effect of Multiple Sequential Light Sources to Activate Aminolevulinic Acid in the Treatment of Actinic Keratoses: A Retrospective Study

    PubMed Central

    Goldman, Mitchel P.; Fabi, Sabrina G.; Guiha, Isabella

    2014-01-01

    There is a lack of research regarding the sequential use of multiple light sources for topical 5-aminolevulinic acid activation in photodynamic therapy for actinic keratosis. This study evaluated 5-aminolevulinic acid-photodynamic therapy for actinic keratosis using blue light combined with red light, pulsed dye laser, and/or intense pulsed light in a retrospective fashion. Field-directed 5-aminolevulinic acid-photodynamic therapy was performed with blue light only, blue light + pulsed dye laser, blue light + intense pulsed light, blue light + pulsed dye laser + intense pulsed light, or blue light + red light + pulsed dye laser + intense pulsed light for nonhyperkeratotic actinic keratoses of face, scalp, or upper trunk. Blue light + intense pulsed light + pulsed dye laser produced greater patient-reported improvement in actinic keratoses than blue light or blue light + intense pulsed light and greater subject-reported improvement in overall skin quality than blue light + intense pulsed light. The addition of red light led to no further benefit in either outcome measure. Photodynamic therapy with multiple, sequential laser and light sources led to greater patient-graded improvement in actinic keratoses than that with a single light source (blue light), without significant differences in post-treatment adverse events. However, the small, widely disparate number of patients between groups and follow-up times between patients, as well as retrospective assessments based on subjective patient recall, severely limit the significance of these findings. Nevertheless, the results raise interesting questions regarding the use of multiple light and laser sources for photodynamic therapy of actinic keratoses and warrant further research with a prospective, randomized, controlled study. PMID:25276272

  8. Motivation and approach to creating true color temperature low light level V-NIR source

    NASA Astrophysics Data System (ADS)

    Scopatz, Stephen D.; Mazzetta, Jason A.; Ennerson, Fred A.

    2010-04-01

    With the continuing innovation in night vision and multispectral imaging technologies, the requirements for more sophisticated test systems continue to increase. Various manufacturers of Visible and Near Infrared (V-NIR) cameras and detection systems need to verify the lowest detectable light level and check system performance at very low light levels as well as recovery from exposure to typical daytime light levels. Typical low level requirements are in the range of 10-4 to 10-6 foot-lamberts, equivalent to starlight radiance levels; typical daytime light levels are 103 foot-lamberts. There is a relatively straightforward approach to producing low light level output using "neutral" density filters to reduce the light to the proper level. Although neutral density filters are not spectrally neutral over the entire V-NIR wavelength range. For some test applications the loss of spectral fidelity is unacceptable for tests of sensor response. The challenge was to create an adjustable output V-NIR source that maintains the color temperature setting over the entire output range. This paper explains how the requirement of True Color Temperature Low Light Level source is met and the benefits compared to prior methods. In addition how the daylight level is also met with the same source. Once the high and low light levels are achieved in a stable and repeatable manner and are calibrated; the unique tests that can be performed with this source are discussed.

  9. High efficiency light source using solid-state emitter and down-conversion material

    DOEpatents

    Narendran, Nadarajah; Gu, Yimin; Freyssinier, Jean Paul

    2010-10-26

    A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

  10. Additional muon calculations for the SLC positron source

    SciTech Connect

    Nelson, W.R.; McCall, R.C.

    1985-04-23

    This note is an update to the muon calculations presented in CN-221 and takes into account: (1) a more complete muon production and transport model, including an estimate of wide angle production based on experimental data, (2) additional earth shielding that will be added on top and both sides of the 2/3 tunnel areas, and (3) a detailed analysis of the earth profile as it pertains to shielding in the direction of the SLAC site boundary. The highest annual dose at the SLAC boundary is found to be 13 mrem/year (4000 hours of operation at 50 kW), and this occurs at a horizontal angle of 0 degrees and a vertical angle of 3.6 degrees relative to the incident beam direction. Although the shielding criteria is 10 mrem/year at the site boundary, the radiation transport model becomes somewhat conservative at large distances from the shield, which should bring the 13 mrem/year number actually well below the criteria. This point is also about 28 feet above the roadway. Extension of this line may strike the ground in the Christmas tree farm beyond the SLAC boundary but there will be additional attenuation due to distance. We do not recommend that any additional shielding be added at this time. 4 refs., 1 fig.

  11. The effect of light-activation sources on tooth bleaching

    PubMed Central

    Baroudi, Kusai; Hassan, Nadia Aly

    2014-01-01

    Vital bleaching is one of the most requested cosmetic dental procedures asked by patients who seek a more pleasing smile. This procedure consists of carbamide or hydrogen peroxide gel applications that can be applied in-office or by the patient (at-home/overnight bleaching system). Some in-office treatments utilise whitening light with the objective of speeding up the whitening process. The objective of this article is to review and summarise the current literature with regard to the effect of light-activation sources on in-office tooth bleaching. A literature search was conducted using Medline, accessed via the National Library of Medicine Pub Med from 2003 to 2013 searching for articles relating to effectiveness of light activation sources on in-office tooth bleaching. This study found conflicting evidence on whether light truly improve tooth whitening. Other factors such as, type of stain, initial tooth colour and subject age which can influence tooth bleaching outcome were discussed. Conclusions: The use of light activator sources with in-office bleaching treatment of vital teeth did not increase the efficacy of bleaching or accelerate the bleaching. PMID:25298598

  12. A mobile light source for carbon/nitrogen cameras

    NASA Astrophysics Data System (ADS)

    Trower, W. P.; Karev, A. I.; Melekhin, V. N.; Shvedunov, V. I.; Sobenin, N. P.

    1995-05-01

    The pulsed light source for carbon/nitrogen cameras developed to image concealed narcotics/explosives is described. This race-track microtron will produce 40 mA pulses of 70 MeV electrons, have minimal size and weight, and maximal ruggedness and reliability, so that it can be transported on a truck.

  13. Prospects for Next-Generation Storage Ring Light Sources

    NASA Astrophysics Data System (ADS)

    Borland, Michael

    2015-04-01

    Storage ring light sources are among the most productive large-scale scientific user facilities in existence, owing to a combination of broad tunability, mature technology, high capacity, remarkable reliability, and high performance. The most commonly-used performance measure is the photon beam brightness, which is proportional to the flux per unit volume in six-dimensional phase space. The brightness is generally maximized by minimizing the transverse phase space area, or emittance, of the electron beam that generates the photons. Since the 1990's, most storage ring light sources have used a variant of the Chasman-Green, or double-bend-achromat (DBA), lattice, which produces transverse emittances of several nanometers. Presently, several light sources are under construction based on more challenging multi-bend-achromat (MBA) concepts, which promise an order of magnitude reduction in the emittance. Somewhat larger reductions are contemplated for upgrades of the largest facilities. This talk briefly surveys the relevant concepts in light source design, then explains both the mechanism and challenge of achieving next-generation emittances. Other factors, such as improved radiation-emitting devices, are also described. Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.

  14. Research by industry at the National Synchrotron Light Source

    SciTech Connect

    1995-05-01

    The world`s foremost facility for research using x-rays and ultraviolet and infrared radiation, is operated by the National Synchrotron Light Source dept. This pamphlet described the participating research teams that built most of the beam lines, various techniques for studying materials, treatment of materials, and various industrial research (catalysis, pharmaceuticals, etc.).

  15. The light curve of a transient X-ray source

    NASA Technical Reports Server (NTRS)

    Kaluzienski, L. J.; Holt, S. S.; Boldt, E. A.; Serlemitsos, P. J.; Eadie, G.; Pounds, K. A.; Ricketts, M. J.; Watson, M.

    1975-01-01

    The Ariel-5 satellite has monitored the X-ray light curve of A1524-62 almost continuously from 40 days prior to maximum light until its disappearance below the effective experimental sensitivity. The source exhibited maximum light on Dec. 4, 1974, at a level of 0.9 the apparent magnitude of the Crab Nebula in the energy band 3-6 keV. Although similar to previously reported transient sources with a decay time constant of about 2 months, the source exhibited an extended, variable preflare on-state of about 1 month at a level of greater than 0.1 maximum light. The four bright (greater than 0.2 of the Crab Nebula) transient sources observed during the first half-year of Ariel-5 operation are indicative of a galactic disk distribution, a luminosity at maximum in excess of 10 to the 37-th power ergs/sec, a frequency of occurrence which may be as high as 100/yr, and a median decay time which is less than 1 month.

  16. Status of the National Synchrotron Light Source project

    SciTech Connect

    Heese, R.N.

    1981-01-01

    The National Synchrotron Light Source is in its final stages of construction, and as the turn-on time for the 700 MeV vuv storage ring draws near, an overview of the project is presented. Emphasis is placed on the linac and booster synchrotron performance and the status of major subsystems.

  17. Enabling instrumentation and technology for 21st century light sources

    SciTech Connect

    Byrd, J.M.; Shea, T.J.; Denes, P.; Siddons, P.; Attwood, D.; Kaertner, F.; Moog, L.; Li, Y.; Sakdinawat, A.; Schlueter, R.

    2010-06-01

    We present the summary from the Accelerator Instrumentation and Technology working group, one of the five working groups that participated in the BES-sponsored Workshop on Accelerator Physics of Future Light Sources held in Gaithersburg, MD September 15-17, 2009. We describe progress and potential in three areas: attosecond instrumentation, photon detectors for user experiments, and insertion devices.

  18. Advanced Light Source Activity Report 1997/1998

    SciTech Connect

    Greiner, Annette

    1999-03-01

    This Lawrence Berkeley National Laboratory, Advanced Light Source (ALS) activity report for 1997/98 discusses the following topics: Introduction and Overview; Science Highlights; Facility Report; Special Events; ALS Advisory Panels 1997/98; ALS Staff 1997/98 and Facts and Figures for the year.

  19. Measurement of storage ring motion at the advanced light source

    SciTech Connect

    Krebs, G.F.

    1997-05-01

    The mechanical stability of the Advanced Light Source storage ring is examined over a period of 1.5 years from the point of view of floor motion. The storage ring beam position monitor stability is examined under various operating conditions.

  20. Compact X-ray Light Source Workshop Report

    SciTech Connect

    Thevuthasan, Suntharampillai; Evans, James E.; Terminello, Louis J.; Koppenaal, David W.; Manke, Kristin L.; Plata, Charity

    2012-12-01

    This report, produced jointly by EMSL and FCSD, is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology.

  1. Superconducting RF Linac Technology for ERL Light Sources

    SciTech Connect

    Tennant, Chris

    2005-08-01

    Energy Recovering Linacs (ERLs) offer an attractive alternative as drivers for light sources as they combine the desirable characteristics of both storage rings (high efficiency) and linear accelerators (superior beam quality). Using superconducting RF technology allows ERLs to operate more efficiently because of the inherent characteristics of SRF linacs, namely that they are high gradient-low impedance structures and their ability to operate in the long pulse or CW regime. We present an overview of the physics challenges encountered in the design and operation of ERL based light sources with particular emphasis on those issues related to SRF technology. These challenges include maximizing a cavity's Qo to increase cryogenic efficiency, maintaining control of the cavity field in the presence of the highest feasible loaded Q and providing adequate damping of the higher-order modes (HOMs). If not sufficiently damped, dipole HOMs can drive the multipass beam breakup (BBU) instability which ERLs are particularly susceptible to. Another challenge involves efficiently extracting the potentially large amounts of HOM power that are generated when a bunch traverses the SRF cavities and which may extend over a high range of frequencies. We present experimental data from the Jefferson Lab FEL Upgrade, a 10 mA ERL light source presently in operation, aimed at addressing some of these issues. We conclude with an outlook towards the future of ERL based light sources.

  2. Miniature Incandescent Lamps as Fiber-Optic Light Sources

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret; Collura, Joe; Helvajian, Henry; Pocha, Michael; Meyer, Glenn; McConaghy, Charles F.; Olsen, Barry L.

    2008-01-01

    Miniature incandescent lamps of a special type have been invented to satisfy a need for compact, rapid-response, rugged, broadband, power-efficient, fiber-optic-coupled light sources for diverse purposes that could include calibrating spectrometers, interrogating optical sensors, spot illumination, and spot heating.

  3. Towards monolithic integration of germanium light sources on silicon chips

    NASA Astrophysics Data System (ADS)

    Saito, Shinichi; Zaher Al-Attili, Abdelrahman; Oda, Katsuya; Ishikawa, Yasuhiko

    2016-04-01

    Germanium (Ge) is a group-IV indirect band gap semiconductor, and therefore bulk Ge cannot emit light efficiently. However, the direct band gap energy is close to the indirect one, and significant engineering efforts are being made to convert Ge into an efficient gain material monolithically integrated on a Si chip. In this article, we will review the engineering challenges of developing Ge light sources fabricated using nano-fabrication technologies compatible with complementary metal-oxide-semiconductor processes. In particular, we review recent progress in applying high-tensile strain to Ge to reduce the direct band gap. Another important technique is doping Ge with donor impurities to fill the indirect band gap valleys in the conduction band. Realization of carrier confinement structures and suitable optical cavities will be discussed. Finally, we will discuss possible applications of Ge light sources in potential photonics-electronics convergent systems.

  4. The Materials Science beamline upgrade at the Swiss Light Source

    PubMed Central

    Willmott, P. R.; Meister, D.; Leake, S. J.; Lange, M.; Bergamaschi, A.; Böge, M.; Calvi, M.; Cancellieri, C.; Casati, N.; Cervellino, A.; Chen, Q.; David, C.; Flechsig, U.; Gozzo, F.; Henrich, B.; Jäggi-Spielmann, S.; Jakob, B.; Kalichava, I.; Karvinen, P.; Krempasky, J.; Lüdeke, A.; Lüscher, R.; Maag, S.; Quitmann, C.; Reinle-Schmitt, M. L.; Schmidt, T.; Schmitt, B.; Streun, A.; Vartiainen, I.; Vitins, M.; Wang, X.; Wullschleger, R.

    2013-01-01

    The Materials Science beamline at the Swiss Light Source has been operational since 2001. In late 2010, the original wiggler source was replaced with a novel insertion device, which allows unprecedented access to high photon energies from an undulator installed in a medium-energy storage ring. In order to best exploit the increased brilliance of this new source, the entire front-end and optics had to be redesigned. In this work, the upgrade of the beamline is described in detail. The tone is didactic, from which it is hoped the reader can adapt the concepts and ideas to his or her needs. PMID:23955029

  5. Improving the Efficiency of Solid State Light Sources

    SciTech Connect

    Joanna McKittrick

    2003-03-31

    This proposal addresses the national need to develop a high efficiency light source for general illumination applications. The goal is to perform research that would lead to the fabrication of a unique solid state, white-emitting light source. This source is based on an InGaN/GaN UV-emitting chip that activates a luminescent material (phosphor) to produce white light. White-light LEDs are commercially available which use UV from a GaN chip to excite a phosphor suspended in epoxy around the chip. Currently, these devices are relatively inefficient. This research will target one technical barrier that presently limits the efficiency of GaN based devices. Improvements in efficiencies will be achieved by improving the internal conversion efficiency of the LED die, by improving the coupling between the die and phosphor(s) to reduce losses at the surfaces, and by selecting phosphors to maximize the emissions from the LEDs in conversion to white light. The UCSD research team proposes for this project to develop new phosphors that have high quantum efficiencies that can be activated by the UV-blue (360-410 nm) light emitted by the GaN device. The main goal for the UCSD team was to develop new phosphor materials with a very specific property: phosphors that could be excited at long UV-wavelengths ({lambda}=350-410 nm). The photoluminescence of these new phosphors must be activated with photons emitted from GaN based dies. The GaN diodes can be designed to emit UV-light in the same range ({lambda}=350-410 nm). A second objective, which is also very important, is to search for alternate methods to fabricate these phosphors with special emphasis in saving energy and time and reduce pollution.

  6. Light emitting diode-based nanosecond ultraviolet light source for fluorescence lifetime measurements

    NASA Astrophysics Data System (ADS)

    Araki, Tsutomu; Misawa, Hiroaki

    1995-12-01

    A compact pulsed-light source is devised from an InGaN/AlGaN double heterostructure light-emitting diode (LED). The LED emits a 450-nm (blue) light under conventional dc operation below 30 mA. When a current larger than 50 mA is applied, the intensity of the 450-nm light saturates, but that of the 380-nm light due to the InGaN component continues to increase. This phenomenon is utilized to realize a nanosecond ultraviolet (UV) light source. Under repetitive, large current pulsing (frequency=10 kHz, pulse width=4 ns, peak current=2 A), the peak LED emission shifts from 450 to 380 nm. Intense light pulses (peak value=40 mW) of 4-ns duration were generated. To evaluate the potential of the pulsed LED as an excitation source, the fluorescence lifetime of a quinine-sulfate solution was measured. The observed lifetime characteristics agreed well with the generally accepted behavior.

  7. Lithography imaging control by enhanced monitoring of light source performance

    NASA Astrophysics Data System (ADS)

    Alagna, Paolo; Zurita, Omar; Lalovic, Ivan; Seong, Nakgeuon; Rechsteiner, Gregory; Thornes, Joshua; D'havé, Koen; Van Look, Lieve; Bekaert, Joost

    2013-04-01

    Reducing lithography pattern variability has become a critical enabler of ArF immersion scaling and is required to ensure consistent lithography process yield for sub-30nm device technologies. As DUV multi-patterning requirements continue to shrink, it is imperative that all sources of lithography variability are controlled throughout the product life-cycle, from technology development to high volume manufacturing. Recent developments of new ArF light-source metrology and monitoring capabilities have been introduced in order to improve lithography patterning control.[1] These technologies enable performance monitoring of new light-source properties, relating to illumination stability, and enable new reporting and analysis of in-line performance.

  8. Performance characteristics of white light sources consisting of multiple light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Li, Yun-Li; Shah, Jay M.; Leung, P.-H.; Gessmann, Thomas; Schubert, E. F.

    2004-01-01

    The performance characteristics of white light sources based on a multiple-LED approach, in particular dichromatic and trichromatic sources are analyzed in detail. Figures of merit such as the luminous efficacy, color temperature, and color rendering capabilities are provided for a wide range of primary emission wavelengths. Spectral power density functions of LEDs are assumed to be thermally and inhomogeneously broadened to a full width at half maximum of several kT, in agreement with experimental results. A gaussian line shape is assumed for each of the emission bands. It is shown that multi-LED white light sources have the potential for luminous efficacies greater than 400 lm/W (dichromatic source) and color rendering indices of greater than 90 (trichromatic source). Contour maps for the color rendering indices and luminous efficacies versus three wavelengths are given.

  9. Light-pollution model for cloudy and cloudless night skies with ground-based light sources.

    PubMed

    Kocifaj, Miroslav

    2007-05-20

    The scalable theoretical model of light pollution for ground sources is presented. The model is successfully employed for simulation of angular behavior of the spectral and integral sky radiance and/or luminance during nighttime. There is no restriction on the number of ground-based light sources or on the spatial distribution of these sources in the vicinity of the measuring point (i.e., both distances and azimuth angles of the light sources are configurable). The model is applicable for real finite-dimensional surface sources with defined spectral and angular radiating properties contrary to frequently used point-source approximations. The influence of the atmosphere on the transmitted radiation is formulated in terms of aerosol and molecular optical properties. Altitude and spectral reflectance of a cloud layer are the main factors introduced for simulation of cloudy and/or overcast conditions. The derived equations are translated into numerically fast code, and it is possible to repeat the entire set of calculations in real time. The parametric character of the model enables its efficient usage by illuminating engineers and/or astronomers in the study of various light-pollution situations. Some examples of numerical runs in the form of graphical results are presented. PMID:17514252

  10. The advanced light source: America`s brightest light for science and industry

    SciTech Connect

    Cross, J.; Lawler, G.

    1994-03-01

    America`s brightest light comes from the Advanced Light Source (ALS), a national facility for scientific research, product development, and manufacturing. Completed in 1993, the ALS produces light in the ultraviolet and x-ray regions of the spectrum. Its extreme brightness provides opportunities for scientific and technical progress not possible anywhere else. Technology is poised on the brink of a major revolution - one in which vital machine components and industrial processes will be drastically miniaturized. Industrialized nations are vying for leadership in this revolution - and the huge economic rewards the leaders will reap.

  11. Dynamics of laser-produced Sn microplasma for a high-brightness extreme ultraviolet light source

    SciTech Connect

    Yuspeh, S.; Tao, Y.; Burdt, R. A.; Tillack, M. S.; Ueno, Y.; Najmabadi, F.

    2011-05-16

    The effect of laser focal spot diameters of 26 and 150 {mu}m on 13.5 nm extreme ultraviolet (EUV) radiation is investigated. Simulations show that the smaller spot size has a shorter electron plasma density scale length and deeper and denser laser energy deposition region. This results in additional time required for plasma expansion and radiation transport to efficiently emit EUV light. This is experimentally observed as an increase in the delay between the EUV emission and the laser pulse. The shorter scale length plasma reabsorbs less EUV light, resulting in a higher conversion efficiency, smaller and slightly brighter light source.

  12. A CMOS microdisplay with integrated controller utilizing improved silicon hot carrier luminescent light sources

    NASA Astrophysics Data System (ADS)

    Venter, Petrus J.; Alberts, Antonie C.; du Plessis, Monuko; Joubert, Trudi-Heleen; Goosen, Marius E.; Janse van Rensburg, Christo; Rademeyer, Pieter; Fauré, Nicolaas M.

    2013-03-01

    Microdisplay technology, the miniaturization and integration of small displays for various applications, is predominantly based on OLED and LCoS technologies. Silicon light emission from hot carrier electroluminescence has been shown to emit light visibly perceptible without the aid of any additional intensification, although the electrical to optical conversion efficiency is not as high as the technologies mentioned above. For some applications, this drawback may be traded off against the major cost advantage and superior integration opportunities offered by CMOS microdisplays using integrated silicon light sources. This work introduces an improved version of our previously published microdisplay by making use of new efficiency enhanced CMOS light emitting structures and an increased display resolution. Silicon hot carrier luminescence is often created when reverse biased pn-junctions enter the breakdown regime where impact ionization results in carrier transport across the junction. Avalanche breakdown is typically unwanted in modern CMOS processes. Design rules and process design are generally tailored to prevent breakdown, while the voltages associated with breakdown are too high to directly interact with the rest of the CMOS standard library. This work shows that it is possible to lower the operating voltage of CMOS light sources without compromising the optical output power. This results in more efficient light sources with improved interaction with other standard library components. This work proves that it is possible to create a reasonably high resolution microdisplay while integrating the active matrix controller and drivers on the same integrated circuit die without additional modifications, in a standard CMOS process.

  13. Light Source for Scanning Method of Size-of-Source Effect Measurement

    NASA Astrophysics Data System (ADS)

    Achmadi, Aditya; Juliastuti, Endang; Handojo, Andrianto; Zaid, Ghufron; Wiriadinata, Hidayat; Park, Seung-Nam

    2015-12-01

    A high-power light-emitting diode (HPLED) is proposed as a new light source for the measurement of the size-of-source effect (SSE) in radiation thermometers. The HPLED is a more compact, simple, and inexpensive light source and is suitable for SSE measurement by the scanning method. An experiment has been done using a 3 W HPLED with a hemispherical front lens and a peak emission wavelength of 660 nm. A linear pyrometer (Model LP4 manufactured by KE) was used for the measurements. The scanning process was carried out by using a computerized linear translation stage spanning 500 mm. To confirm the measurement result, the SSE of the LP4 was also measured by the conventional indirect method using an integrating sphere with a 65 mm diameter exit port. The same trends of the SSE value of the scanning and indirect method were found in all ranges of the indirect method measurement. The results show that the light source has enough brightness and a sufficiently wide angular distribution to provide a dynamic measurement range of up to 108 and allow the measurement of the SSE up to a radius of 500 mm. These results support the application of HPLED as an alternative light source for SSE measurements by the scanning method.

  14. Method and apparatus for acquisition and tracking of light sources in a transient event rich environment

    NASA Technical Reports Server (NTRS)

    Kissh, Frank (Inventor); Flynn, David (Inventor); Fowski, Walter (Inventor); Abreu, Rene (Inventor); Miklus, Kenneth (Inventor); Bolin, Kenneth (Inventor)

    1993-01-01

    A method and apparatus for tracking a light source in a transient event rich environment locks on to a light source incident on a field-of-view 1 of a charge-coupled-device (CCD) array 6, validates the permanence of said light source and transmits data relating to the brilliance and location of said light source if said light source is determined to be permanent.

  15. Advanced Compton scattering light source R&D at LLNL

    SciTech Connect

    Albert, F; Anderson, S G; Anderson, G; Betts, S M; Chu, T S; Gibson, D J; Marsh, R A; Messerly, M; Shverdin, M Y; Wu, S; Hartemann, F V; Siders, C W; Barty, C P

    2010-02-16

    We report the design and current status of a monoenergetic laser-based Compton scattering 0.5-2.5 MeV {gamma}-ray source. Previous nuclear resonance fluorescence results and future linac and laser developments for the source are presented. At MeV photon energies relevant for nuclear processes, Compton scattering light sources are attractive because of their relative compactness and improved brightness above 100 keV, compared to typical 4th generation synchrotrons. Recent progress in accelerator physics and laser technology have enabled the development of a new class of tunable Mono-Energetic Gamma-Ray (MEGa-Ray) light sources based on Compton scattering between a high-brightness, relativistic electron beam and a high intensity laser pulse produced via chirped-pulse amplification (CPA). A new precision, tunable gamma-ray source driven by a compact, high-gradient X-band linac is currently under development and construction at LLNL. High-brightness, relativistic electron bunches produced by an X-band linac designed in collaboration with SLAC will interact with a Joule-class, 10 ps, diode-pumped CPA laser pulse to generate tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range via Compton scattering. Based on the success of the previous Thomson-Radiated Extreme X-rays (T-REX) Compton scattering source at LLNL, the source will be used to excite nuclear resonance fluorescence lines in various isotopes; applications include homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. After a brief presentation of successful nuclear resonance fluorescence (NRF) experiments done with T-REX, the new source design, key parameters, and current status are presented.

  16. OLEDs as prospective light sources for microstructured photoreactors.

    PubMed

    Ziegenbalg, Dirk; Kreisel, Günter; Weiß, Dieter; Kralisch, Dana

    2014-07-01

    In this work, the use of OLEDs as light sources to initiate photochemical reactions is presented for the first time. A newly developed modular photoreactor system utilising microstructured reactors was equipped with commercially available OLED panels. The technical feature of being a surface emitter, the low thickness and the potentially high luminescent efficiency give reason to expect this kind of light source to be well suited for photochemical reactions. The reactor system was investigated by using photooxygenations as benchmark reactions. In detail, photosensitised [4 + 2]-cycloadditions and [2 + 2]-cycloadditions of (1)O2 were examined as well as Schenck-ene-reactions. It was demonstrated that OLEDs can be successfully used for conducting photochemical reactions. Moreover the equilibrium concentration of (1)O2 can be increased by varying the process conditions. Based on the experimental investigations, a reactor comparison showed that, with respect to productivity and efficiency, the investigated microstructured photoreactor is currently not outperforming conventional batch reactors.

  17. Hyperspectral retinal imaging with a spectrally tunable light source

    NASA Astrophysics Data System (ADS)

    Francis, Robert P.; Zuzak, Karel J.; Ufret-Vincenty, Rafael

    2011-03-01

    Hyperspectral retinal imaging can measure oxygenation and identify areas of ischemia in human patients, but the devices used by current researchers are inflexible in spatial and spectral resolution. We have developed a flexible research prototype consisting of a DLP®-based spectrally tunable light source coupled to a fundus camera to quickly explore the effects of spatial resolution, spectral resolution, and spectral range on hyperspectral imaging of the retina. The goal of this prototype is to (1) identify spectral and spatial regions of interest for early diagnosis of diseases such as glaucoma, age-related macular degeneration (AMD), and diabetic retinopathy (DR); and (2) define required specifications for commercial products. In this paper, we describe the challenges and advantages of using a spectrally tunable light source for hyperspectral retinal imaging, present clinical results of initial imaging sessions, and describe how this research can be leveraged into specifying a commercial product.

  18. X-ray detectors at the Linac Coherent Light Source

    SciTech Connect

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; Herrmann, Sven; Kenney, Chris; Markovic, Bojan; Nishimura, Kurtis; Osier, Shawn; Pines, Jack; Reese, Benjamin; Segal, Julie; Tomada, Astrid; Weaver, Matt

    2015-04-21

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

  19. Cathode R&D for future light sources.

    SciTech Connect

    Dowell, D. H.; Bazarov, I.; Dunham, B.; Harkay, K.; Hernandez-Garcia, C.; Legg, R.; Padmore, H.; Rao, T.; Smedley, J.; Wan, W.; Accelerator Systems Division; SLAC National Accelerator Lab.; Cornell Univ.; Thomas Jefferson Lab.; Univ. of Wisconsin; LBNL; BNL

    2010-03-18

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  20. Cathode R&D for Future Light Sources

    SciTech Connect

    Dowell, D.H.; Bazarov, I.; Dunham, B.; Harkay, K.; Hernandez-Garcia; Legg, R.; Padmore, H.; Rao, T.; Smedley, J.; Wan, W.; /LBL, Berkeley

    2010-05-26

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  1. X-ray detectors at the Linac Coherent Light Source

    PubMed Central

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; Herrmann, Sven; Kenney, Chris; Markovic, Bojan; Nishimura, Kurtis; Osier, Shawn; Pines, Jack; Reese, Benjamin; Segal, Julie; Tomada, Astrid; Weaver, Matt

    2015-01-01

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced. PMID:25931071

  2. X-ray detectors at the Linac Coherent Light Source

    DOE PAGES

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; et al

    2015-04-21

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a newmore » generation of cameras under development at SLAC, is introduced.« less

  3. Insertion devices for the Advanced Light Source at LBL

    SciTech Connect

    Hassenzahl, W.; Chin, J.; Halbach, K.; Hoyer, E.; Humphries, D.; Kincaid, B.; Savoy, R.

    1989-03-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory will be the first of the new generation of dedicated synchrotron light sources to be put into operation. Specially designed insertion devices will be required to realize the high brightness photon beams made possible by the low emittance of the electron beam. The complement of insertion devices on the ALS will include undulators with periods as short as 3.9 cm and one or more high field wigglers. The first device to be designed is a 5 m long, 5 cm period, hybrid undulator. The goal of very high brightness and high harmonic output imposes unusually tight tolerances on the magnetic field quality and thus on the mechanical structure. The design process, using a generic structure for all undulators, is described. 5 refs., 4 figs., 1 tab.

  4. Ultraminiature broadband light source with spiral shaped filament

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L. (Inventor); Collura, Joseph S. (Inventor); Helvajian, Henry (Inventor); Pocha, Michael D. (Inventor); Meyer, Glenn A. (Inventor); McConaghy, Charles F. (Inventor); Olsen, Barry L. (Inventor); Hansen, William W (Inventor)

    2012-01-01

    An ultraminiature light source using a double-spiral shaped tungsten filament includes end contact portions which are separated to allow for radial and length-wise unwinding of the spiral. The double-spiral filament is spaced relatively far apart at the end portions thereof so that contact between portions of the filament upon expansion is avoided. The light source is made by fabricating a double-spiral ultraminiature tungsten filament from tungsten foil and housing the filament in a ceramic package having a reflective bottom and a well wherein the filament is suspended. A vacuum furnace brazing process attaches the filament to contacts of the ceramic package. Finally, a cover with a transparent window is attached onto the top of the ceramic package by solder reflow in a second vacuum furnace process to form a complete hermetically sealed package.

  5. Shielding synchrotron light sources: Advantages of circular shield walls tunnels

    NASA Astrophysics Data System (ADS)

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.

    2016-08-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.

  6. Electron Beam Collimation for the Next Generation Light Source

    SciTech Connect

    Steier, C.; Emma, P.; Nishimura, H.; Papadopoulos, C.; Sannibale, F.

    2013-05-20

    The Next Generation Light Source will deliver high (MHz) repetition rate electron beams to an array of free electron lasers. Because of the significant average current in such a facility, effective beam collimation is extremely important to minimize radiation damage to undulators, prevent quenches of superconducting cavities, limit dose rates outside of the accelerator tunnel and prevent equipment damage. This paper describes the early conceptual design of a collimation system, as well as initial results of simulations to test its effectiveness.

  7. MOPA configuration light source with 5 W output power

    NASA Astrophysics Data System (ADS)

    Kaczmarek, Pawel; Soboń, Grzegorz; WÄ Ż, Adam; Dudzik, Grzegorz; Antończak, Arkadiusz; Abramski, Krzysztof

    2013-01-01

    In this paper we present a device - fiber based coherent light source operating at 1550 nm wavelength and 5 W of the output power. It is made completely of the fiber elements without any bulk optics therefore it is stable and resistant to the environmental conditions. The main idea was to use so called MOPA (Master Oscillator Power Amplifier) configuration to obtain universal design. Thus the device can be easily configured to work in couple different operation regimes.

  8. Smart LED light source driver for machine vision system

    NASA Astrophysics Data System (ADS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2008-02-01

    The unique properties of LEDs offer significant advantages in terms of lifetime, intensity and color control, response time and efficiency, all of which are very important for illumination in machine vision applications. However, there are some drawbacks of LEDs, such as the high thermal dependency and temporal degradation of the intensity and color. Dealing with these drawbacks requires complex LED drivers, which are able to compensate for the abovementioned changes in the intensity and color, thereby maintaining higher stability over a wide range of ambient temperature throughout the lifetime of a LED light source. Moreover, state-of-the-art machine vision systems usually consist of a large number of independent LED light sources that enable real-time switching between different illumination setups at frequencies of up to 100 kHz. In this paper, we discuss the concepts of smart LED drivers with the emphasis on the flexibility and applicability. All the most important characteristics are being considered and discussed in detail: the accurate generation of high frequency waveforms, the efficiency of the current driver, thermal and temporal stabilization of the LED intensity and color, communication with a camera and personal computer or embedded system, and practicalities of implementing a large number of independent drive channels. Finally, a practical solution addressing all of the abovementioned issues is proposed with the aim of providing a flexible and highly stable smart LED light source driver for state-of-the-art machine vision systems.

  9. Ultraviolet light output of compact fluorescent lamps: comparison to conventional incandescent and halogen residential lighting sources.

    PubMed

    Nuzum-Keim, A D; Sontheimer, R D

    2009-05-01

    Patients with photosensitive dermatologic and systemic diseases often question the ultraviolet light (UVL) output of household lighting sources. Such individuals have increasing concern about potential UVL exposure from energy-efficient compact fluorescent lamps (CFL), as little data have been presented concerning their UVL output. The objective was to compare, via pilot study, the levels of ultraviolet A (UVA) and ultraviolet B (UVB) leak between residential lighting sources. Equivalent wattage CFL, incandescent and halogen bulbs were purchased from local retailers in Oklahoma City, Oklahoma, USA. The UVA and UVB outputs of these sources were measured under controlled conditions at 10, 25, 50, 100 and 150 cm away from the light source using an IL-1700 research radiometer equipped with UVA and UVB detectors. Negligible UVB and UVA was detected at 100 and 150 cm. Therefore, data were analysed from measurements at 10, 25 and 50 cm only. The results demonstrated UVA leak highest from incandescent and halogen bulbs, and UVB leak highest from CFL. The overall UVA/UVB leak was lowest from CFL shielded during the manufacturing process. In conclusion, patients with photosensitivity have choices depending on their relative risk from different UVL wavelength spectra. UVB exposure risk may be reduced the greatest by utilising CFL with manufacturer-provided shields.

  10. Stray light in cone beam optical computed tomography: II. Reduction using a convergent light source

    NASA Astrophysics Data System (ADS)

    Dekker, Kurtis H.; Battista, Jerry J.; Jordan, Kevin J.

    2016-04-01

    Optical cone beam computed tomography (CBCT) using a broad beam and CCD camera is a fast method for densitometry of 3D optical gel dosimeters. However, diffuse light sources introduce considerable stray light into the imaging system, leading to underestimation of attenuation coefficients and non-uniformities in CT images unless corrections are applied to each projection image. In this study, the light source of a commercial optical CT scanner is replaced with a convergent cone beam source consisting of almost exclusively image forming primary rays. The convergent source is achieved using a small isotropic source and a Fresnel lens. To characterize stray light effects, full-field cone beam CT imaging is compared to fan beam CT (FBCT) using a 1 cm high fan beam aperture centered on the optic axis of the system. Attenuating liquids are scanned within a large 96 mm diameter uniform phantom and in a small 13.5 mm diameter finger phantom. For the uniform phantom, cone and fan beam CT attenuation coefficients agree within a maximum deviation of (1  ±  2)% between mean values over a wide range from 0.036 to 0.43 cm-1. For the finger phantom, agreement is found with a maximum deviation of (4  ±  2)% between mean values over a range of 0.1-0.47 cm-1. With the convergent source, artifacts associated with refractive index mismatch and vessel optical features are more pronounced. Further optimization of the source size to achieve a balance between quantitative accuracy and artifact reduction should enable practical, accurate 3D dosimetry, avoiding time consuming 3D scatter measurements.

  11. Mapping algorithm for freeform construction using non-ideal light sources

    NASA Astrophysics Data System (ADS)

    Li, Chen; Michaelis, D.; Schreiber, P.; Dick, L.; Bräuer, A.

    2015-09-01

    Using conventional mapping algorithms for the construction of illumination freeform optics' arbitrary target pattern can be obtained for idealized sources, e.g. collimated light or point sources. Each freeform surface element generates an image point at the target and the light intensity of an image point is corresponding to the area of the freeform surface element who generates the image point. For sources with a pronounced extension and ray divergence, e.g. an LED with a small source-freeform-distance, the image points are blurred and the blurred patterns might be different between different points. Besides, due to Fresnel losses and vignetting, the relationship between light intensity of image points and area of freeform surface elements becomes complicated. These individual light distributions of each freeform element are taken into account in a mapping algorithm. To this end the method of steepest decent procedures are used to adapt the mapping goal. A structured target pattern for a optics system with an ideal source is computed applying corresponding linear optimization matrices. Special weighting factor and smoothing factor are included in the procedures to achieve certain edge conditions and to ensure the manufacturability of the freefrom surface. The corresponding linear optimization matrices, which are the lighting distribution patterns of each of the freeform surface elements, are gained by conventional raytracing with a realistic source. Nontrivial source geometries, like LED-irregularities due to bonding or source fine structures, and a complex ray divergence behavior can be easily considered. Additionally, Fresnel losses, vignetting and even stray light are taken into account. After optimization iterations, with a realistic source, the initial mapping goal can be achieved by the optics system providing a structured target pattern with an ideal source. The algorithm is applied to several design examples. A few simple tasks are presented to discussed

  12. Sole-Source Lighting for Controlled-Environment Agriculture

    NASA Technical Reports Server (NTRS)

    Mitchell.Cary; Stutte, Gary W.

    2015-01-01

    Since plants on Earth evolved under broad-spectrum solar radiation, anytime they are grown exclusively under electric lighting that does not contain all wavelengths in similar proportion to those in sunlight, plant appearance and size could be uniquely different. Nevertheless, plants have been grown for decades under fluorescent (FL) (1) + incandescent (IN) (2) lamps as a sole source of lighting (SSL), and researchers have become comfortable that, in certain proportions of FL + IN for a given species, plants can appear "normal" relative to their growth outdoors. The problem with using such traditional SSLs for commercial production typically is short lamp lifespans and not obtaining enough photosynthetically active radiation (PAR, 400-700 nm) when desired. These limitations led to supplementation of FL + IN lamp outputs with longer-lived, high-intensity discharge (HID) lamps in growth chambers (3). As researchers became comfortable that mixes of orange-biased high-pressure sodium (HPS) and blue-biased metal halide (MH) HIDs together also could give normal plant growth at higher intensities, growth chambers and phytotrons subsequently were equipped mainly with HID lamps, with their intense thermal output filtered out by ventilated light caps or thermal-controlled water barriers. For the most part, IN and HID lamps have found a home in commercial protected horticulture, usually for night-break photoperiod lighting (IN) or for seasonal supplemental lighting (mostly HPS) in greenhouses. However, lack of economically viable options for SSL have held back aspects of year-round indoor agriculture from taking off commercially.

  13. Beacon system based on light-emitting diode sources for runways lighting

    NASA Astrophysics Data System (ADS)

    Montes, Mario González; Vázquez, Daniel; Fernandez-Balbuena, Antonio A.; Bernabeu, Eusebio

    2014-06-01

    New aeronautical ground lighting techniques are becoming increasingly important to ensure the safety and reduce the maintenance costs of the plane's tracks. Until recently, tracks had embedded lighting systems whose sources were based on incandescent lamps. But incandescent lamps have several disadvantages: high energy consumption and frequent breakdowns that result in high maintenance costs (lamp average life-time is ˜1500 operating hours) and the lamp's technology has a lack of new lighting functions, such as signal handling and modification. To solve these problems, the industry has developed systems based on light-emitting diode (LED) technology with improved features: (1) LED lighting consumes one tenth the power, (2) it improves preventive maintenance (an LED's lifetime range is between 25,000 and 100,000 hours), and (3) LED lighting technology can be controlled remotely according to the needs of the track configuration. LEDs have been in use for more than three decades, but only recently, around 2002, have they begun to be used as visual aids, representing the greatest potential change for airport lighting since their inception in the 1920s. Currently, embedded LED systems are not being broadly used due to the specific constraints of the rules and regulations of airports (beacon dimensions, power system technology, etc.). The fundamental requirements applied to embedded lighting systems are to be hosted on a volume where the dimensions are usually critical and also to integrate all the essential components for operation. An embedded architecture that meets the lighting regulations for airport runways is presented. The present work is divided into three main tasks: development of an optical system to optimize lighting according to International Civil Aviation Organization, manufacturing prototype, and model validation.

  14. Multifrequency light curves of low-frequency variable radio sources

    NASA Technical Reports Server (NTRS)

    Altschuler, D. R.; Broderick, J. J.; Dennison, B.; Mitchell, K. J.; Odell, S. L.; Condon, J. J.; Payne, H. E.

    1984-01-01

    Light curves for the low-frequency variable sources AO 0235 + 16, NRAO 140, PKS 1117 + 14, DA 406, CTA 102, and 3C 454.3, obtained in monthly observations at 318, 430, and 606 MHz using the 305-m telescope at Arecibo and in bimonthly observations at 880 MHz and 1.4 GHz using the 91-m Green Bank transit telescope during 1980-1983, are presented and analyzed. AO 0235 + 16 is found to have basically canonical variability which is attributed to relativistically moving evolving synchrotron components; but in the other sources, strong simultaneous variations at 318, 430, and 606 MHz are observed to be greatly diminished in amplitude at 880 MHz and 1.4 GHz, confirming the existence of the intermediate-frequency gap at about 1 GHz proposed by Spangler and Cotton (1981). The possibility that a second variability mechanism is active in these sources is explored.

  15. Linac Coherent Light Source: The first five years

    NASA Astrophysics Data System (ADS)

    Bostedt, Christoph; Boutet, Sébastien; Fritz, David M.; Huang, Zhirong; Lee, Hae Ja; Lemke, Henrik T.; Robert, Aymeric; Schlotter, William F.; Turner, Joshua J.; Williams, Garth J.

    2016-01-01

    A new scientific frontier opened in 2009 with the start of operations of the world's first x-ray free-electron laser (FEL), the Linac Coherent Light Source (LCLS), at SLAC National Accelerator Laboratory. LCLS provides femtosecond pulses of x rays (270 eV to 11.2 keV) with very high peak brightness to access new domains of ultrafast x-ray science. This article presents the fundamental FEL physics and outlines the LCLS source characteristics along with the experimental challenges, strategies, and instrumentation that accompany this novel type of x-ray source. The main part of the article reviews the scientific achievements since the inception of LCLS in the five primary areas it serves: atomic, molecular, and optical physics; condensed matter physics; matter in extreme conditions; chemistry and soft matter, and biology.

  16. The linac coherent light source single particle imaging road map

    PubMed Central

    Aquila, A.; Barty, A.; Bostedt, C.; Boutet, S.; Carini, G.; dePonte, D.; Drell, P.; Doniach, S.; Downing, K. H.; Earnest, T.; Elmlund, H.; Elser, V.; Gühr, M.; Hajdu, J.; Hastings, J.; Hau-Riege, S. P.; Huang, Z.; Lattman, E. E.; Maia, F. R. N. C.; Marchesini, S.; Ourmazd, A.; Pellegrini, C.; Santra, R.; Schlichting, I.; Schroer, C.; Spence, J. C. H.; Vartanyants, I. A.; Wakatsuki, S.; Weis, W. I.; Williams, G. J.

    2015-01-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources. PMID:26798801

  17. The linac coherent light source single particle imaging road map

    SciTech Connect

    Aquila, A.; Barty, A.; Bostedt, C.; Boutet, S.; Carini, G.; dePonte, D.; Drell, P.; Doniach, S.; Downing, K. H.; Earnest, T.; Elmlund, H.; Elser, V.; Gühr, M.; Hajdu, J.; Hastings, J.; Hau-Riege, S. P.; Huang, Z.; Lattman, E. E.; Maia, F. R.N.C.; Marchesini, S.; Ourmazd, A.; Pellegrini, C.; Schlichting, I.; Schroer, C.; Spence, J. C. H.; Vartanyants, I. A.; Wakatsuki, S.; Weis, W. I.; Williams, G. J.

    2015-07-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.

  18. The linac coherent light source single particle imaging road map

    DOE PAGES

    Aquila, A.; Barty, A.; Bostedt, C.; Boutet, S.; Carini, G.; dePonte, D.; Drell, P.; Doniach, S.; Downing, K. H.; Earnest, T.; et al

    2015-07-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electronmore » laser sources.« less

  19. The linac coherent light source single particle imaging road map.

    PubMed

    Aquila, A; Barty, A; Bostedt, C; Boutet, S; Carini, G; dePonte, D; Drell, P; Doniach, S; Downing, K H; Earnest, T; Elmlund, H; Elser, V; Gühr, M; Hajdu, J; Hastings, J; Hau-Riege, S P; Huang, Z; Lattman, E E; Maia, F R N C; Marchesini, S; Ourmazd, A; Pellegrini, C; Santra, R; Schlichting, I; Schroer, C; Spence, J C H; Vartanyants, I A; Wakatsuki, S; Weis, W I; Williams, G J

    2015-07-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.

  20. The linac coherent light source single particle imaging road map.

    PubMed

    Aquila, A; Barty, A; Bostedt, C; Boutet, S; Carini, G; dePonte, D; Drell, P; Doniach, S; Downing, K H; Earnest, T; Elmlund, H; Elser, V; Gühr, M; Hajdu, J; Hastings, J; Hau-Riege, S P; Huang, Z; Lattman, E E; Maia, F R N C; Marchesini, S; Ourmazd, A; Pellegrini, C; Santra, R; Schlichting, I; Schroer, C; Spence, J C H; Vartanyants, I A; Wakatsuki, S; Weis, W I; Williams, G J

    2015-07-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources. PMID:26798801

  1. Photoacoustic imaging of clinical metal needle by a LED light source integrated transducer

    NASA Astrophysics Data System (ADS)

    Agano, Toshitaka; Sato, Naoto; Nakatsuka, Hitoshi; Kitagawa, Kazuo; Hanaoka, Takamitsu; Morisono, Koji; Shigeta, Yusuke; Tanaka, Chizuyo

    2016-03-01

    We have achieved penetration depth of 30mm by photoacoustic imaging system using LED light source integrated transducer to image a clinical metal needle inserted into a tissue mimicking phantom. We developed the transducer that integrated near-infrared LED array light source, which was connected to a photoacoustic imaging system which drove LED array light source and controlled photoacoustic data acquisition process. Conventionally solid-state laser has been used as the light source for photoacoustic imaging system. Because LED is diffused light source, laser safety glasses is not necessary, also inflexible fibers are not used to guide light close to a transducer, and we integrated LED light source inside the transducer, which became compact and practical size for conventional ultrasound equipment users. We made LED light source unit as detachable to the transducer easily, so wave-length of light can be selectable by changing the LED light source unit.

  2. Light source comprising a common substrate, a first led device and a second led device

    SciTech Connect

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  3. Evaluation of White Light Sources For an Absolute Fiber Optic Sensor Readout System

    SciTech Connect

    McConaghy, C F

    2003-10-10

    This report summarizes work done in pursuit of an absolute readout system for Fabry-Perot optics sensors such as those built both by FISO and LLNL. The use of white light results in a short coherence length reducing the ambiguity of the Fabry-Perot gap measurement which is required to readout the sensor. The light source coherence length is the critical parameter in determining the ability to build a relative or an absolute system. Optical sources such as lasers and LEDs are rather narrow in optical spectral bandwidth and have long coherence length. Thus, when used in interferometric sensor measurements, one fringe looks much like another and it is difficult to make an absolute measurement. In contrast, white light sources are much broader in spectral bandwidth and have very short coherence lengths making interferometry possible only over the coherence length, which can be 1 or 2 microns. The small number of fringes in the interferogram make it easier to calculate the centroid and to unambiguously determine the sensor gap. However, unlike LEDs and Lasers, white light sources have very low optical power when coupled into optical fibers. Although, the overall light output of a white light source can be hundreds of milliwatts to watts, it is difficult to couple more than microwatts into a 50-micron core optical fiber. In addition, white light sources have a large amount of optical power in spectrum that is not necessarily useful in terms of sensor measurements. The reflectivity of a quarter wave of Titanium Oxide is depicted in Figure 2. This coating of Titanium Oxide is used in the fabrication of the sensor. This figure shows that any light emitted at wavelengths shorter than 600 nm is not too useful for the readout system. A white light LED spectrum is depicted in Figure 3 and shows much of the spectrum below 600 nm. In addition Silicon photodiodes are usually used in the readout system limiting the longest wavelength to about 1100 nm. Tungsten filament sources may

  4. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  5. The Use of Light-Emitting Diodes (LEDs) as Green and Red/Far-Red Light Sources in Plant Physiology.

    ERIC Educational Resources Information Center

    Jackson, David L.; And Others

    1985-01-01

    The use of green, red, and far-red light-emitting diodes (LEDs) as light sources for plant physiological studies is outlined and evaluated. Indicates that LED lamps have the advantage over conventional light sources in that they are lightweight, low-cost, portable, easily constructed, and do not require color filters. (Author/DH)

  6. A lighting assembly based on red and blue light-emitting diodes as a lighting source for space agriculture

    NASA Astrophysics Data System (ADS)

    Avercheva, Olga; Berkovich, Yuliy A.; Smolyanina, Svetlana; Bassarskaya, Elizaveta; Zhigalova, Tatiana; Ptushenko, Vasiliy; Erokhin, Alexei

    Light-emitting diodes (LEDs) are a promising lighting source for space agriculture due to their high efficiency, longevity, safety, and other factors. Assemblies based on red and blue LEDs have been recommended in literature, although not all plants show sufficient productivity in such lighting conditions. Adding of green LEDs proposed in some works was aimed at psychological support for the crew, and not at the improvement of plant growth. We studied the growth and the state of the photosynthetic apparatus in Chinese cabbage (Brassica chinensis L.) plants grown under red (650 nm) and blue (470 nm) light-emitting diodes (LEDs). Plants grown under a high-pressure sodium lamp (HPS lamp) were used as a control. The plants were illuminated with two photosynthetic photon flux levels: nearly 400 µE and about 100 µE. Plants grown under LEDs with 400 µE level, as compared to control plants, showed lower fresh weight, edible biomass, growth rate, and sugar content. The difference in fresh weight and edible biomass was even more pronounced in plants grown with 100 µE level; the data indicate that the adaptability of the test plants to insufficient lighting decreased. Under LEDs, we observed the decreasing of root growth and the absence of transition to the flowering stage, which points to a change in the hormonal balance in plants grown in such lighting conditions. We also found differences in the functioning of the photosynthetic apparatus and its reaction to a low lighting level. We have concluded that a lighting assembly with red and blue LEDs only is insufficient for the plant growth and productivity, and can bring about alterations in their adaptive and regulatory mechanisms. Further studies are needed to optimize the lighting spectrum for space agriculture, taking into account the photosynthetic, phototropic and regulatory roles of light. Using white LEDs or adding far-red and green LEDs might be a promising approach.

  7. An Optically Stabilized Fast-Switching Light Emitting Diode as a Light Source for Functional Neuroimaging

    PubMed Central

    Wagenaar, Daniel A.

    2012-01-01

    Neuroscience research increasingly relies on optical methods for evoking neuronal activity as well as for measuring it, making bright and stable light sources critical building blocks of modern experimental setups. This paper presents a method to control the brightness of a high-power light emitting diode (LED) light source to an unprecedented level of stability. By continuously monitoring the actual light output of the LED with a photodiode and feeding the result back to the LED's driver by way of a proportional-integral controller, drift was reduced to as little as 0.007% per hour over a 12-h period, and short-term fluctuations to 0.005% root-mean-square over 10 seconds. The LED can be switched on and off completely within 100 s, a feature that is crucial when visual stimuli and light for optical recording need to be interleaved to obtain artifact-free recordings. The utility of the system is demonstrated by recording visual responses in the central nervous system of the medicinal leech Hirudo verbana using voltage-sensitive dyes. PMID:22238663

  8. Effect of two natural light regimes and nutrient addition on the forest herb Begonia decandra (Begoniaceae).

    PubMed

    Cordero, R A

    2000-01-01

    The effect of two natural light-growing conditions (understory versus light gaps) and the interaction with nutrient availability (through fertilization) were studied in the understory herb Begonia decandra, in the Luquillo Experimental Forest in Puerto Rico. Sixteen potted plants obtained from cuttings were randomly chosen and distributed in each of eighth forest environments (four light gaps and four understories), for a total of 128 plants. Fertilizer was applied to half of the plants in each site. After seven months in the two given microenvironments, increased light and fertilization resulted in greater growth and some changes in the biomass allocation patterns. All measured variables responded similarly to reported changes for tree seedlings and saplings from other tropical and subtropical regions. Total growth parameters (height, biomass and leaf area) were very sensitive to increases in the main resource (light). The addition of nutrients was less important in producing changes in the allocation variables (root to shoot ratio, leaf area ratio, and specific leaf mass) under conditions of high light availability. Changes due to nutrient levels were relatively greater on plants grown under under-story conditions. Also, small light differences among sites can cause significant changes in the variables related to total growth. Lastly, plant mortality in the nutrient treatments was found to be independent of mortality in two forest light environments. Some hypotheses about resource acquisition and plant growth are not supported by this data.

  9. Boron-Containing Red Light-Emitting Phosphors And Light Sources Incorporating The Same

    DOEpatents

    Srivastava, Alok Mani; Comanzo, Holly Ann; Manivannan, Venkatesan

    2006-03-28

    A boron-containing phosphor comprises a material having a formula of AD1-xEuxB9O16, wherein A is an element selected from the group consisting of Ba, Sr, Ca, Mg, and combinations thereof; D is at least an element selected from the group consisting of rare-earth metals other than europium; and x is in the range from about 0.005 to about 0.5. The phosphor is used in a blend with other phosphors in a light source for generating visible light with a high color rendering index.

  10. Concepts for the PEP-X Light Source

    SciTech Connect

    Hettel, Robert; Bane, Karl; Bertsche, Kirk; Cai, Yunhai; Chao, Alex; Dolgashev, Valery; Fox, John; Huang, Xiaobiao; Huang, Zhirong; Mastorides, Themistoklis; Ng, Cho; Nosochkov, Yuri; Novokhatski, Alexander; Rabedeau, Thomas; Rivetta, Claudio; Safranek, James; Seeman, John; Stohr, Joachim; Stupakov, Gennady; Tantawi, Sami G.; Wang, Lanfa; /SLAC /Stanford U. /UCLA

    2010-08-26

    SSRL and SLAC groups are developing a long-range plan to transfer its evolving scientific programs from the SPEAR3 light source to a much higher performing photon source that would be housed in the 2.2-km PEP-II tunnel. While various concepts for the PEP-X light source are under consideration, including ultimate storage ring and ERL configurations, the present baseline design is a very low-emittance storage ring. A hybrid lattice has double bend achromat (DBA) cells in two of the six arcs that provide a total 30 straight sections for insertion device (ID) beam lines extending into two new experimental halls. The remaining arcs contain TME cells. Using 90 m of damping wigglers the horizontal emittance at 4.5 GeV would be 100 pm-rad with 1.5-A stored beam. PEP-X will produce photon beams having brightnesses near 10{sup 22} (ph/s/mm{sup 2}/mrad{sup 2}/0.1% BW) at 10 keV. Studies indicate that a 90-m undulator could have FEL gain and brightness enhancement at soft x-ray wavelengths with the stored beam. Crab cavities or other beam manipulation systems could be used to reduce bunch length or otherwise enhance photon emission properties. The present status of the design of PEP-X as a storage ring is presented.

  11. Simulation of multicomponent light source for optical-electronic system of color analysis objects

    NASA Astrophysics Data System (ADS)

    Peretiagin, Vladimir S.; Alekhin, Artem A.; Korotaev, Valery V.

    2016-04-01

    Development of lighting technology has led to possibility of using LEDs in the specialized devices for outdoor, industrial (decorative and accent) and domestic lighting. In addition, LEDs and devices based on them are widely used for solving particular problems. For example, the LED devices are widely used for lighting of vegetables and fruit (for their sorting or growing), textile products (for the control of its quality), minerals (for their sorting), etc. Causes of active introduction LED technology in different systems, including optical-electronic devices and systems, are a large choice of emission color and LED structure, that defines the spatial, power, thermal and other parameters. Furthermore, multi-element and color devices of lighting with adjustable illumination properties can be designed and implemented by using LEDs. However, devices based on LEDs require more attention if you want to provide a certain nature of the energy or color distribution at all the work area (area of analysis or observation) or surface of the object. This paper is proposed a method of theoretical modeling of the lighting devices. The authors present the models of RGB multicomponent light source applied to optical-electronic system for the color analysis of mineral objects. The possibility of formation the uniform and homogeneous on energy and color illumination of the work area for this system is presented. Also authors showed how parameters and characteristics of optical radiation receiver (by optical-electronic system) affect on the energy, spatial, spectral and colorimetric properties of a multicomponent light source.

  12. Ultraminiature Broadband Light Source and Method of Manufacturing Same

    NASA Technical Reports Server (NTRS)

    Tuma, Margaret L. (Inventor); Collura, Joseph S. (Inventor); Helvajian, Henry (Inventor); Pocha, Michael D. (Inventor); Meyer, Glenn A. (Inventor); McConaghy, Charles F. (Inventor); Olsen, Barry L. (Inventor); Hansen, William W. (Inventor)

    2010-01-01

    An ultraminiature light source using a double-spiral shaped tungsten filament includes end contact portions which are separated to allow for radial and length-wise unwinding of the spiral. The double-spiral filament is spaced relatively far apart at the end portions thereof so that contact between portions of the filament upon expansion is avoided. The light ource is made by fabricating a double-spiral ultraminiature tungsten filament from tungsten foil and housing the filament in a ceramic package having a reflective bottom and a well wherein the filament is suspended. A vacuum furnace brazing process attaches the filament to contacts of the ceramic package. Finally, a cover with a transparent window is attached onto the top of the ceramic package by solder reflow in a second vacuum furnace process to form a complete hermetically sealed package.

  13. Colliding pulse mode-locked lasers as light sources for single-shot holography

    NASA Astrophysics Data System (ADS)

    Grosse, Doris; Koukourakis, Nektarios; Gerhardt, Nils C.; Schlauch, Tobias; Balzer, Jan C.; Klehr, Andreas; Erbert, Götz; Tränkle, Günther; Hofmann, Martin R.

    2011-05-01

    So far, concepts for three dimensional biomedical imaging rely on scanning in at least one dimension. Single-shot holography1, in contrast, stores three-dimensional information encoded in an electro-magnetic wave scattered back from a sample in one single hologram. Single-shot holography operates with simultaneous recordings of holograms at different wavelengths. While the lateral sample information is stored in the interference patterns of individual holograms, the depth information is obtained from the spectral distribution at each lateral image point, similar to Fourier-domain optical coherence tomography2. Consequently, the depth resolution of the reconstructed image is determined by the bandwidth of the light source, so that a broadband light source is needed to obtain high depth resolution. Additionally, the holographic material, in which the holograms are stored, restricts the useable bandwidth. A thick photorefractive crystal can store several holograms of different wavelengths at once. As the crystal works best when using a source with a discrete spectrum, a light source is needed that has a spectrum with well distinguishable laser lines. In a proof-of-principle experiment, we use colliding pulse mode-locked (CPM)3 laser diodes as light sources with a comb-like spectrum to demonstrate the concept of single-shot holography by storing multiple holograms at the same time in a photorefractive Rh:BaTiO3 crystal.

  14. JLab CW Cryomodules for 4th Generation Light Sources

    SciTech Connect

    Rimmer, Robert; Bundy, Richard; Cheng, Guangfeng; Ciovati, Gianluigi; Clemens, William; Daly, Edward; Henry, James; Hicks, William; Kneisel, Peter; Manning, Stephen; Manus, Robert; Marhauser, Frank; Preble, Joseph; Reece, Charles; Smith, Karl; Stirbet, Mircea; Turlington, Larry; Wang, Haipeng; Wilson, Katherine

    2008-01-23

    Fourth generation light sources hold the prospect of unprecedented brightness and optical beam quality for a wide range of scientific applications. Many of the proposed new facilities will rely on large superconducting radio frequency (SRF) based linacs to provide high energy, low emittance CW electron beams. For high average power applications there is a growing acceptance of energy recovery linac (ERL) technology as the way to support large recirculating currents with modest RF power requirements. CW SRF and high current ERLs are two core competencies at Jefferson Lab. JLab has designed and built a number of CW cryomodules of several different types starting with the original CEBAF design, with variations for higher current in the two generations of JLab’s free-electron laser (FEL), through two intermediate prototypes to the final high-performance module for the 12 GeV upgrade. Each of these represent fully engineered and tested configurations with a variety of specifications that could be considered for possible use in fourth generation light sources. Furthermore JLab has been actively pursuing advanced concepts for highcurrent high-efficiency cryomodules for next generation ERL based FEL’s. These existing and proposed designs span the range from about 1mA single-pass to over 100 mA energy recovered current capability. Specialized configurations also exist for high-current non-energy recovered sections such as the injector region where very high RF power is required. We discuss the performance parameters of these existing and proposed designs and their suitability to different classes of fourth generation light sources.

  15. Limit of concentration for cylindrical concentrators under extended light sources.

    PubMed

    Miñano, J C; Luque, A

    1983-08-15

    Cylindrical concentrators illuminated by an extended source with an arbitrary distribution of radiance are analyzed taking into account basic properties derived from the Fermat principle and not from the specific concentrator shape. The upper limit of concentration achievable with this type of concentrator is obtained and it is found to be lower than that of general (3-D) concentrators. Cylindrical compound parabolic concentrators are analyzed in the light of this theory, and it is shown that they achieve the highest optical concentration possible for a cylindrical concentrator. PMID:18196152

  16. Billion particle linac simulations for future light sources

    SciTech Connect

    Ryne, R. D.; Venturini, M.; Zholents, A. A.; Qiang, J.

    2008-09-25

    In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

  17. Optical laser systems at the Linac Coherent Light Source

    DOE PAGES

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; Edstrom, Steve; Gilevich, Sasha; Glownia, James M.; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C.; Miahnahri, Alan; et al

    2015-04-22

    Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS.

  18. Ultrabright Laser-based MeV-class Light Source

    SciTech Connect

    Albert, F; Anderson, G; Anderson, S; Bayramian, A; Berry, B; Betts, S; Dawson, J; Ebbers, C; Gibson, D; Hagmann, C; Hall, J; Hartemann, F; Hartouni, E; Heebner, J; Hernandez, J; Johnson, M; Messerly, M; McNabb, D; Phan, H; Pruet, J; Semenov, V; Shverdin, M; Sridharan, A; Tremaine, A; Siders, C W; Barty, C J

    2008-04-02

    We report first light from a novel, new source of 10-ps 0.776-MeV gamma-ray pulses known as T-REX (Thomson-Radiated Extreme X-rays). The MeV-class radiation produced by TREX is unique in the world with respect to its brightness, spectral purity, tunability, pulse duration and laser-like beam character. With T-REX, one can use photons to efficiently probe and excite the isotope-dependent resonant structure of atomic nucleus. This ability will be enabling to an entirely new class of isotope-specific, high resolution imaging and detection capabilities.

  19. Producing terahertz coherent synchrotron radiation at the Hefei Light Source

    NASA Astrophysics Data System (ADS)

    Xu, De-Rong; Xu, Hong-Liang; Shao, Yan

    2015-07-01

    This paper theoretically proves that an electron storage ring can generate coherent radiation in the THz region using a quick kicker magnet and an AC sextupole magnet. When the vertical chromaticity is modulated by the AC sextupole magnet, the vertical beam collective motion excited by the kicker produces a wavy spatial structure after a number of longitudinal oscillation periods. The radiation spectral distribution was calculated from the wavy bunch parameters at the Hefei Light Source (HLS). When the electron energy is reduced to 400 MeV, extremely strong coherent synchrotron radiation (CSR) at 0.115 THz should be produced. Supported by National Natural Science Foundation of China (11375176)

  20. Optical laser systems at the Linac Coherent Light Source

    PubMed Central

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; Edstrom, Steve; Gilevich, Sasha; Glownia, James M.; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C.; Miahnahri, Alan; Milathianaki, Despina; Polzin, Wayne; Ratner, Daniel; Tavella, Franz; Vetter, Sharon; Welch, Marc; White, William E.; Fry, Alan R.

    2015-01-01

    Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS. PMID:25931064

  1. Status report on the Advanced Light Source control system, 1993

    SciTech Connect

    Young, J.; Brown, W. Jr.; Cork, C.

    1993-10-01

    The Advanced Light Source (ALS), under construction for the past seven years, has become operational. The accelerator has been successfully commissioned using a control system based on hundreds of controllers of our own design and high performance personal computers which are the operator interface. The first beamlines are being commissioned using a control system based on VME hardware and the Experimental Physics and Industrial Control System (EPICS) software. The two systems are being integrated, and this paper reports on the current work being done.

  2. Optical laser systems at the Linac Coherent Light Source.

    PubMed

    Minitti, Michael P; Robinson, Joseph S; Coffee, Ryan N; Edstrom, Steve; Gilevich, Sasha; Glownia, James M; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C; Miahnahri, Alan; Milathianaki, Despina; Polzin, Wayne; Ratner, Daniel; Tavella, Franz; Vetter, Sharon; Welch, Marc; White, William E; Fry, Alan R

    2015-05-01

    Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump-probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump-probe experiments to be performed at LCLS.

  3. The Advanced Light Source (ALS) Slicing Undulator Beamline

    SciTech Connect

    Heimann, P. A.; Glover, T. E.; Plate, D.; Brown, V. C.; Padmore, H. A.; Lee, H. J.; Schoenlein, R. W.

    2007-01-19

    A beamline optimized for the bunch slicing technique has been construction at the Advanced Light Source (ALS). This beamline includes an in-vacuum undulator, soft and hard x-ray beamlines and a femtosecond laser system. The soft x-ray beamline may operate in spectrometer mode, where an entire absorption spectrum is accumulated at one time, or in monochromator mode. The femtosecond laser system has a high repetition rate of 20 kHz to improve the average slicing flux. The performance of the soft x-ray branch of the ALS slicing undulator beamline will be presented.

  4. Broadband visible light source based on AllnGaN light emitting diodes

    DOEpatents

    Crawford, Mary H.; Nelson, Jeffrey S.

    2003-12-16

    A visible light source device is described based on a light emitting diode and a nanocluster-based film. The light emitting diode utilizes a semiconductor quantum well structure between n-type and p-type semiconductor materials on the top surface a substrate such as sapphire. The nanocluster-based film is deposited on the bottom surface of the substrate and can be derived from a solution of MoS.sub.2, MoSe.sub.2, WS.sub.2, and WSe.sub.2 particles of size greater than approximately 2 nm in diameter and less than approximately 15 nm in diameter, having an absorption wavelength greater than approximately 300 nm and less than approximately 650 nm.

  5. Explosive Vessel for Dynamic Experiments at Advanced Light Sources

    NASA Astrophysics Data System (ADS)

    Owens, Charles; Sorensen, Christian; Armstrong, Christopher; Sanchez, Nathaniel; Jensen, Brian

    2015-06-01

    There has been significant effort in coupling dynamic loading platforms to advanced light sources such as the Advanced Photon Source (APS) to take advantage of X-ray diagnostics for examining material physics at extremes. Although the focus of these efforts has been on using gun systems for dynamic compression experiments, there are many experiments that require explosive loading capabilities including studies related to detonator dynamics, small angle X-ray scattering on explosives, and ejecta formation, for example. To this end, an explosive vessel and positioning stage was designed specifically for use at a synchrotron with requirements to confine up to 15 grams of explosives, couple the vessel to the X-ray beam line, and reliably position samples in the X-ray beam remotely with micrometer spatial accuracy. In this work, a description of the system will be provided along with explosive testing results for the robust, reusable positioning system.

  6. The risk of retina damage from high intensity light sources.

    PubMed

    Pollak, V A; Romanchuk, K G

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excessive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A mehtod of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  7. Penning plasma based simultaneous light emission source of visible and VUV lights

    NASA Astrophysics Data System (ADS)

    Vyas, G. L.; Prakash, R.; Pal, U. N.; Manchanda, R.; Halder, N.

    2016-06-01

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20-106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  8. High-Efficiency Nitride-Base Photonic Crystal Light Sources

    SciTech Connect

    James Speck; Evelyn Hu; Claude Weisbuch; Yong-Seok Choi; Kelly McGroddy; Gregor Koblmuller; Elison Matioli; Elizabeth Rangel; Fabian Rol; Dobri Simeonov

    2010-01-31

    The research activities performed in the framework of this project represent a major breakthrough in the demonstration of Photonic Crystals (PhC) as a competitive technology for LEDs with high light extraction efficiency. The goals of the project were to explore the viable approaches to manufacturability of PhC LEDS through proven standard industrial processes, establish the limits of light extraction by various concepts of PhC LEDs, and determine the possible advantages of PhC LEDs over current and forthcoming LED extraction concepts. We have developed three very different geometries for PhC light extraction in LEDs. In addition, we have demonstrated reliable methods for their in-depth analysis allowing the extraction of important parameters such as light extraction efficiency, modal extraction length, directionality, internal and external quantum efficiency. The information gained allows better understanding of the physical processes and the effect of the design parameters on the light directionality and extraction efficiency. As a result, we produced LEDs with controllable emission directionality and a state of the art extraction efficiency that goes up to 94%. Those devices are based on embedded air-gap PhC - a novel technology concept developed in the framework of this project. They rely on a simple and planar fabrication process that is very interesting for industrial implementation due to its robustness and scalability. In fact, besides the additional patterning and regrowth steps, the process is identical as that for standard industrially used p-side-up LEDs. The final devices exhibit the same good electrical characteristics and high process yield as a series of test standard LEDs obtained in comparable conditions. Finally, the technology of embedded air-gap patterns (PhC) has significant potential in other related fields such as: increasing the optical mode interaction with the active region in semiconductor lasers; increasing the coupling of the incident

  9. A squeezed light source operated under high vacuum.

    PubMed

    Wade, Andrew R; Mansell, Georgia L; Chua, Sheon S Y; Ward, Robert L; Slagmolen, Bram J J; Shaddock, Daniel A; McClelland, David E

    2015-01-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments.

  10. A squeezed light source operated under high vacuum.

    PubMed

    Wade, Andrew R; Mansell, Georgia L; Chua, Sheon S Y; Ward, Robert L; Slagmolen, Bram J J; Shaddock, Daniel A; McClelland, David E

    2015-01-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments. PMID:26657616

  11. Breast tumor detection using continuous wave light source

    NASA Astrophysics Data System (ADS)

    Zhao, Shiyin; O'Leary, Maureen A.; Nioka, Shoko; Chance, Britton

    1995-05-01

    The detection of small amounts of indocyanine green (ICG) in small volumes would suggest its potential use in the detection of early breast tumors. While phased array has already shown its ability to sharply localize small amounts of ICG in the picomole region, the question has arisen, what would be the comparable sensitivity of continous light systems for the same purpose? If this were a comparable sensitivity, the advantages of the simplest of opto- electronic systems and the use of light intensity not limited to those available under FDA regulations for laser diodes could be realized. In this research work, we investigate two methods of enhancing the contrast agent between diseased and healthy tissue using low frequency amplitude modulated light sources. The first method exploits the symmetry between the left and right breast and the second exploits the cylindrical symmetry of the breast. Both effect are enhanced by the use of an injected contrast agent (ICG). Based on the theory and model study, several human subjects cases were studied in the Hospital of the University of Pennsylvania. The results show that the peak signal can get about 60 seconds after ICG injection through the vein and then will take few minutes to get back to the baseline. The half decay time and maximum (Delta) OD are dependent of the characteristics of the breast tissue.

  12. A squeezed light source operated under high vacuum

    NASA Astrophysics Data System (ADS)

    Wade, Andrew R.; Mansell, Georgia L.; Chua, Sheon S. Y.; Ward, Robert L.; Slagmolen, Bram J. J.; Shaddock, Daniel A.; McClelland, David E.

    2015-12-01

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments.

  13. An electrically excited nanoscale light source with active angular control of the emitted light.

    PubMed

    Le Moal, Eric; Marguet, Sylvie; Rogez, Benoît; Mukherjee, Samik; Dos Santos, Philippe; Boer-Duchemin, Elizabeth; Comtet, Geneviève; Dujardin, Gérald

    2013-09-11

    We report on the angular distribution, polarization, and spectrum of the light emitted from an electrically controlled nanoscale light source. This nanosource of light arises from the local, low-energy, electrical excitation of localized surface plasmons (LSP) on individual gold nanoparticles using a scanning tunneling microscope (STM). The gold nanoparticles (NP) are chemically synthesized truncated bitetrahedrons. The emitted light is collected through the transparent substrate and the emission characteristics (angular distribution, polarization, and spectrum) are analyzed. These three observables are found to strongly depend on the lateral position of the STM tip with respect to the triangular upper face of the gold NP. In particular, the resulting light emission changes orientation when the electrical excitation via the STM tip is moved from the base to the vertex of the triangular face. On the basis of the comparison of the experimental observations with an analytical dipole model and finite-difference time-domain (FDTD) calculations, we show that this behavior is linked to the selective excitation of the out-of-plane and in-plane dipolar LSP modes of the NP. This selective excitation is achieved through the lateral position of the tip with respect to the symmetry center of the NP.

  14. Future Synchrotron Light Sources Based on Ultimate Storage Rings

    SciTech Connect

    Cai, Yunhai; /SLAC

    2012-04-09

    The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving an ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend achromatic cell, we

  15. Polymerization shrinkage stress of composites photoactivated by different light sources.

    PubMed

    Pires-de-Souza, Fernanda de Carvalho Panzeri; Drubi Filho, Brahim; Casemiro, Luciana Assirati; Garcia, Lucas da Fonseca Roberti; Consani, Simonides

    2009-01-01

    The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (alpha=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress. PMID:20069256

  16. Terahertz Light Source and User Area at FACET

    SciTech Connect

    Wu, Z.; Li, S.Z.; Litos, M.; Fisher, A.D.; Hogan, M.J.; /SLAC

    2011-11-08

    FACET at SLAC provides high charge, high peak current, low emittance electron beam that is bunched at THz wavelength scale during its normal operation. A THz light source based coherent transition radiation (CTR) from this beam would potentially be the brightest short-pulse THz source ever constructed. Efforts have been put into building this photon source together with a user area, to provide a platform to utilize this unique THz radiation for novel nonlinear and ultrafast phenomena researches and experiments. Being a long-time underutilized portion of the electromagnetic spectrum, terahertz (100 GHz {approx} 10 THz) spectral range is experiencing a renaissance in recent years, with broad interests from chemical and biological imaging, material science, telecommunication, semiconductor and superconductor research, etc. Nevertheless, the paucity of THz sources especially strong THz radiation hinders both its commercial applications and nonlinear processes research. FACET - Facilities for Accelerator science and Experimental Test beams at SLAC - provides 23 GeV electron beam with peak currents of {approx} 20 kA that can be focused down to 100 {mu}m{sup 2} transversely. Such an intense electron beam, when compressed to sub-picosecond longitudinal bunch length, coherently radiates high intensity EM fields well within THz frequency range that are orders of magnitude stronger than those available from laboratory tabletop THz sources, which will enable a wide variety of THz related research opportunities. Together with a description of the FACET beamline and electron beam parameters, this paper will report FACET THz radiation generation via coherent transition radiation and calculated photon yield and power spectrum. A user table is being set up along the THz radiation extraction sites, and equipped with various signal diagnostics including THz power detector, Michelson interferometer, sample stages, and sets of motorized optical components. This setup will also be

  17. The Advanced Light Source: A third-generation Synchrotron Radiation Source

    SciTech Connect

    Robinson, Arthur L.

    2002-08-14

    The Advanced Light Source (ALS) at the E.O. Lawrence Berkeley National Laboratory (Berkeley Lab) of the University of California is a ''third-generation'' synchrotron radiation source optimized for highest brightness at ultraviolet and soft x-ray photon energies. It also provides world-class performance at hard x-ray photon energies. Berkeley Lab operates the ALS for the United States Department of Energy as a national user facility that is available 24 hours/day around the year for research by scientists from industrial, academic, and government laboratories primarily from the United States but also from abroad.

  18. Optical Pumping Experiments on Next Generation Light Sources

    SciTech Connect

    Moon, S J; Fournier, K B; Scott, H; Chung, H K; Lee, R W

    2004-07-29

    Laser-based plasma spectroscopic techniques have been used with great success to determine the line shapes of atomic transitions in plasmas, study the population kinetics of atomic systems embedded in plasmas, and look at the redistribution of radiation. However, the possibilities for optical lasers end for plasmas with n{sub e}>10{sup 22}cm{sup -3} as light propagation is severely altered by the plasma. The construction of the Tesla Test Facility(TTF) at DESY(Deutsche Elektronen-Synchrotron), a short pulse tunable free electron laser in the vacuum-ultraviolet and soft X-ray regime (VUV FEL), based on the SASE(self amplified spontaneous emission) process, will provide a major advance in the capability for dense plasma-related research. This source will provide 10{sup 13} photons in a 200 fs duration pulse that is tunable from {approx} 6nm to 100nm. Since an VUV FEL will not have the limitation associated with optical lasers the entire field of high density plasmas kinetics in laser produced plasma will then be available to study with tunable source. Thus, one will be able to use this and other FEL x-ray sources to pump individual transitions creating enhanced population in the excited states that can easily be monitored. We show two case studies illuminating different aspects of plasma spectroscopy.

  19. Light-emitting diodes as a radiation source for plants

    NASA Technical Reports Server (NTRS)

    Bula, R. J.; Morrow, R. C.; Tibbitts, T. W.; Barta, D. J.; Ignatius, R. W.; Martin, T. S.

    1991-01-01

    Development of a more effective radiation source for use in plant-growing facilities would be of significant benefit for both research and commercial crop production applications. An array of light-emitting diodes (LEDs) that produce red radiation, supplemented with a photosynthetic photon flux (PPF) of 30 micromoles s-1 m-2 in the 400- to 500-nm spectral range from blue fluorescent lamps, was used effectively as a radiation source for growing plants. Growth of lettuce (Lactuca sativa L. Grand Rapids') plants maintained under the LED irradiation system at a total PPF of 325 micromoles s-1 m-2 for 21 days was equivalent to that reported in the literature for plants grown for the same time under cool-white fluorescent and incandescent radiation sources. Characteristics of the plants, such as leaf shape, color, and texture, were not different from those found with plants grown under cool-white fluorescent lamps. Estimations of the electrical energy conversion efficiency of a LED system for plant irradiation suggest that it may be as much as twice that published for fluorescent systems.

  20. Color-dulling solid-state sources of light.

    PubMed

    Žukauskas, Artūras; Vaicekauskas, Rimantas; Shur, Michael

    2012-04-23

    The spectral power distributions (SPDs) of solid-state sources were optimized for rendering the highest number of colors with a perceptually noticeable reduction in chroma (dulling) while maintaining the hue distortion below an acceptable threshold. Statistical color rendition indices derived from the analysis of color-shift vectors of 1269 Munsell samples were used in the objective functions for the optimization of SPDs of the color-dulling sources. The starting optimization point was the SPD composed of narrow yellow and blue (YB) emissions, which both dulls colors and distorts hues. Two methods were applied to reduce the hue-distorting effect of the narrow-band YB source. The first method, broadening the spectral bands, yields SPDs similar to that of a dichromatic white light-emitting diode (LED) with the partial conversion of narrow-band blue electroluminescence to wide-band yellow photoluminescence. The second method, multiplying the spectral bands, results in the SPDs similar to those of trichromatic clusters of red, yellow, and blue (RYB) and amber, green, and blue (AGB) LEDs. PMID:22535067

  1. Light-emitting diodes as a radiation source for plants.

    PubMed

    Bula, R J; Morrow, R C; Tibbitts, T W; Barta, D J; Ignatius, R W; Martin, T S

    1991-02-01

    Development of a more effective radiation source for use in plant-growing facilities would be of significant benefit for both research and commercial crop production applications. An array of light-emitting diodes (LEDs) that produce red radiation, supplemented with a photosynthetic photon flux (PPF) of 30 micromoles s-1 m-2 in the 400- to 500-nm spectral range from blue fluorescent lamps, was used effectively as a radiation source for growing plants. Growth of lettuce (Lactuca sativa L. Grand Rapids') plants maintained under the LED irradiation system at a total PPF of 325 micromoles s-1 m-2 for 21 days was equivalent to that reported in the literature for plants grown for the same time under cool-white fluorescent and incandescent radiation sources. Characteristics of the plants, such as leaf shape, color, and texture, were not different from those found with plants grown under cool-white fluorescent lamps. Estimations of the electrical energy conversion efficiency of a LED system for plant irradiation suggest that it may be as much as twice that published for fluorescent systems.

  2. Light-assisted drying (LAD) of small volume biologics: a comparison of two IR light sources

    NASA Astrophysics Data System (ADS)

    Young, Madison A.; Van Vorst, Matthew; Elliott, Gloria D.; Trammell, Susan R.

    2016-03-01

    Protein therapeutics have been developed to treat diseases ranging from arthritis and psoriasis to cancer. A challenge in the development of protein-based drugs is maintaining the protein in the folded state during processing and storage. We are developing a novel processing method, light-assisted drying (LAD), to dehydrate proteins suspended in a sugar (trehalose) solution for storage at supra-zero temperatures. Our technique selectively heats the water in small volume samples using near-IR light to speed dehydration which prevents sugar crystallization that can damage embedded proteins. In this study, we compare the end moisture content (EMC) as a function of processing time of samples dried with two different light sources, Nd:YAG (1064 nm) and Thulium fiber (1850 nm) lasers. EMC is the ratio of water to dry weight in a sample and the lower the EMC the higher the possible storage temperature. LAD with the 1064 and 1850 nm lasers yielded 78% and 65% lower EMC, respectively, than standard air-drying. After 40 minutes of LAD with 1064 and 1850 nm sources, EMCs of 0.27+/-.27 and 0.15+/-.05 gH2O/gDryWeight were reached, which are near the desired value of 0.10 gH2O/gDryWeight that enables storage in a glassy state without refrigeration. LAD is a promising new technique for the preparation of biologics for anhydrous preservation.

  3. State of Art in the Science and Technology of Electrical Discharge Light Sources

    NASA Astrophysics Data System (ADS)

    Zissis, Georges; Rouffet, Jean-Baptiste

    Light is vital for life: Light sources play an indispensable role to daily life of any Human being. Our World cannot be conceived without light. Quality of life, health and, somehow, urban security related with traffic and crime prevention measures depend on light and on its quality. The lighting industry is an important economic factor in Europe, USA and many Asiatic Countries. All in all, lighting is an important socio-economic factor and lighting system development should be an integral part of any Sustainable Development and of any program of improvement of Quality of Life. This presentation provides an overview of the present state of research in the science and technology of light sources. Existing technologies and future challenges for the lighting industry will be presented. To better understanding the light source technology an part of this presentation will be devoted to the physics of light sources.

  4. Light-emitting diodes as an illumination source for plants: a review of research at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Kim, Hyeon-Hye; Wheeler, Raymond M.; Sager, John C.; Yorio, Neil C.; Goins, Gregory D.

    2005-01-01

    The provision of sufficient light is a fundamental requirement to support long-term plant growth in space. Several types of electric lamps have been tested to provide radiant energy for plants in this regard, including fluorescent, high-pressure sodium, and metal halide lamps. These lamps vary in terms of spectral quality, which can result in differences in plant growth and morphology. Current lighting research for space-based plant culture is focused on innovative lighting technologies that demonstrate high electrical efficiency and reduced mass and volume. Among the lighting technologies considered for space are light-emitting diodes (LEDs). The combination of red and blue LEDs has proven to be an effective lighting source for several crops, yet the appearance of plants under red and blue lighting is purplish gray, making visual assessment of plant health difficult. Additional green light would make the plant leaves appear green and normal, similar to a natural setting under white light, and may also offer psychological benefits for the crew. The addition of 24% green light (500-600 nm) to red and blue LEDs enhanced the growth of lettuce plants compared with plants grown under cool white fluorescent lamps. Coincidentally, these plants grown under additional green light would have the additional aesthetic appeal of a green appearance.

  5. Light-emitting diodes as an illumination source for plants: a review of research at Kennedy Space Center.

    PubMed

    Kim, Hyeon-Hye; Wheeler, Raymond M; Sager, John C; Yorio, Neil C; Goins, Gregory D

    2005-01-01

    The provision of sufficient light is a fundamental requirement to support long-term plant growth in space. Several types of electric lamps have been tested to provide radiant energy for plants in this regard, including fluorescent, high-pressure sodium, and metal halide lamps. These lamps vary in terms of spectral quality, which can result in differences in plant growth and morphology. Current lighting research for space-based plant culture is focused on innovative lighting technologies that demonstrate high electrical efficiency and reduced mass and volume. Among the lighting technologies considered for space are light-emitting diodes (LEDs). The combination of red and blue LEDs has proven to be an effective lighting source for several crops, yet the appearance of plants under red and blue lighting is purplish gray, making visual assessment of plant health difficult. Additional green light would make the plant leaves appear green and normal, similar to a natural setting under white light, and may also offer psychological benefits for the crew. The addition of 24% green light (500-600 nm) to red and blue LEDs enhanced the growth of lettuce plants compared with plants grown under cool white fluorescent lamps. Coincidentally, these plants grown under additional green light would have the additional aesthetic appeal of a green appearance.

  6. X-ray Optics for BES Light Source Facilities

    SciTech Connect

    Mills, Dennis; Padmore, Howard; Lessner, Eliane

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  7. High precision digital control LED spot light source used to calibrate camera

    NASA Astrophysics Data System (ADS)

    Du, Boyu; Xu, Xiping; Liu, Yang

    2015-04-01

    This paper introduces a method of using LED point light source as the camera calibration light. According to the characteristics of the LED point light source, the constant current source is used to provide the necessary current and the illuminometer is used to measure the luminance of the LED point light source. The constant current source is controlled by ARM MCU and exchange data with the host computer though the mode of serial communications. The PC is used as the host computer, it adjust the current according to the luminance of the LED point light source until the luminance achieve the anticipated value. By experimental analysis, we found that the LED point light source can achieve the desired requirements as the calibration light source, and the accuracy is quite better that achieve the desired effect and it can adaptive control the luminance of LED well. The system is convenient and flexible, and its performance is stable and reliable.

  8. The CERN antiproton source: Controls aspects of the additional collector ring and fast sampling devices

    NASA Astrophysics Data System (ADS)

    Chohan, V.

    1990-08-01

    The upgrade of the CERN antiproton source, meant to gain an order of magnitude in antiproton flux, required the construction of an additional ring to complement the existing antiproton accumulator (AA) and an entire rebuild of the target zone. The AA also needed major modifications to handle the increased flux and perform purely as an accumulator, preceded by collection in the collector ring (AC). The upgrade, known as the ACOL (antiproton collector) project, was approved under strict time and budgetary constraints and the existing AA control system, based on the Proton Synchrotron (PS) Divisional norms of CAMAC and Norsk-Data computers, had to be extended in the light of this. The limited (9 months) installation period for the whole upgrade meant that substantial preparatory and planning activities had to be carried out during the normal running of the AA. Advantage was taken of the upgrade to improve and consolidate the AA. Some aspects of the control system related to this upgrade are discussed together with the integration of new applications and instrumentation. The overall machine installation and running-in was carried out within the defined milestones and the project has now achieved the physics design goals.

  9. Continuous-wave optical fiber based supercontinuum light source

    NASA Astrophysics Data System (ADS)

    Lu, Z. G.; Song, Y.; Liu, J. R.; Zhang, X. P.

    2007-11-01

    We have demonstrated a continuum-wave (CW) supercontinuum (SC) fiber light source with over 1000 nm bandwidth based on a low-cost erbium/ytterbium co-doped double-cladding fiber ring cavity laser. Based on the observation to the SC evolvement, we have experimentally analyzed the detailed contributions of several nonlinear effects within highly nonlinear dispersion-shifted fiber (HNLF). Our experimental results have clearly indicated that four-wave mixing (FWM) and stimulated Raman scattering (SRS) play key roles in CW-pumped SC generation. At the same time, self-phase modulation (SPM) mainly contributes to generate new frequency components near the peaks that appear in the form of the spectra broadening while cross-phase modulation (XPM) enhances the broadening of peaks.

  10. Performance of Advanced Light Source particle beam diagnostics

    SciTech Connect

    Hinkson, J.

    1993-05-01

    The Advanced Light Source (ALS), a third-generation synchrotron radiation facility, is complete. The particle beam diagnostics have been installed and tested. The beam injection systems have been running for two years. We have performance data on beam position monitors, beam intensity monitors, scintillators, beam collimators, a 50 {Omega} Faraday cup, and broad-band striplines and kickers used in the linac, transport lines, and the booster synchrotron. The single-turn monitoring capability of the booster beam position monitoring system has been particularly useful for studying beam dynamics. Beam diagnostics for the storage ring are being commissioned. In this paper we describe each instrument, show its performance, and outline how the instruments are controlled and their output data displayed.

  11. Laue diffraction protein crystallography at the National Synchrotron Light Source

    SciTech Connect

    Getzoff, E.D.; McRee, D. ); Jones, K.W.; Spanne, P.; Sweet, R.M. ); Moffat, K.; Ng, K.; Rivers, M.L.; Schildkamp, W.; Teng, T.Y. ); Singer, P.T.; Westbrook, E.M. )

    1992-01-01

    A new facility for the study of protein crystal structure using Laue diffraction has been established at the X26 beam line of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The characteristics of the beam line and diffraction apparatus are described. Selected results of some of the initial experiments are discussed briefly by beam line users to illustrate the scope of the experimental program. Because the Laue method permits the recording of large data sets in a single shot, one goal in establishing this facility has been to develop the means to study time-resolved structures within protein crystals. Systems being studied include: the reactions catalyzed by trypsin; photolysis of carbonmonoxy myoglobin; and the photocycle of photoactive yellow protein.

  12. Laue diffraction protein crystallography at the National Synchrotron Light Source

    SciTech Connect

    Getzoff, E.D.; McRee, D.; Jones, K.W.; Spanne, P.; Sweet, R.M.; Moffat, K.; Ng, K.; Rivers, M.L.; Schildkamp, W.; Teng, T.Y.; Singer, P.T.; Westbrook, E.M.

    1992-12-31

    A new facility for the study of protein crystal structure using Laue diffraction has been established at the X26 beam line of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The characteristics of the beam line and diffraction apparatus are described. Selected results of some of the initial experiments are discussed briefly by beam line users to illustrate the scope of the experimental program. Because the Laue method permits the recording of large data sets in a single shot, one goal in establishing this facility has been to develop the means to study time-resolved structures within protein crystals. Systems being studied include: the reactions catalyzed by trypsin; photolysis of carbonmonoxy myoglobin; and the photocycle of photoactive yellow protein.

  13. Supercontinuum as a light source for miniaturized endoscopes

    PubMed Central

    Lu, M. K.; Lin, H. Y.; Hsieh, C. C.; Kao, F. J.

    2016-01-01

    In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, including color rendering index (CRI: 72%~97%) and correlated color temperature (CCT: 3,100K~5,200K), are modified with external filters and compared with those from a LED light source (CRI~76% & CCT~6,500K). The very high spatial coherence of the supercontinuum allows high luminosity conduction through a single multimode fiber (core size~400μm), whose distal end tip is attached with a diffussion tip to broaden the solid angle of illumination (from less than 10° to more than 80°).

  14. Workshop on scientific applications of short wavelength coherent light sources

    SciTech Connect

    Spicer, W.; Arthur, J.; Winick, H.

    1993-02-01

    This report contains paper on the following topics: A 2 to 4nm High Power FEL On the SLAC Linac; Atomic Physics with an X-ray Laser; High Resolution, Three Dimensional Soft X-ray Imaging; The Role of X-ray Induced Damage in Biological Micro-imaging; Prospects for X-ray Microscopy in Biology; Femtosecond Optical Pulses ; Research in Chemical Physics Surface Science, and Materials Science, with a Linear Accelerator Coherent Light Source; Application of 10 GeV Electron Driven X-ray Laser in Gamma-ray Laser Research; Non-Linear Optics, Fluorescence, Spectromicroscopy, Stimulated Desorption: We Need LCLS' Brightness and Time Scale; Application of High Intensity X-rays to Materials Synthesis and Processing; LCLS Optics: Selected Technological Issues and Scientific Opportunities; Possible Applications of an FEL for Materials Studies in the 60 eV to 200 eV Spectral Region.

  15. Workshop on scientific applications of short wavelength coherent light sources

    SciTech Connect

    Spicer, W.; Arthur, J.; Winick, H.

    1993-02-01

    This report contains paper on the following topics: A 2 to 4nm High Power FEL On the SLAC Linac; Atomic Physics with an X-ray Laser; High Resolution, Three Dimensional Soft X-ray Imaging; The Role of X-ray Induced Damage in Biological Micro-imaging; Prospects for X-ray Microscopy in Biology; Femtosecond Optical Pulses?; Research in Chemical Physics Surface Science, and Materials Science, with a Linear Accelerator Coherent Light Source; Application of 10 GeV Electron Driven X-ray Laser in Gamma-ray Laser Research; Non-Linear Optics, Fluorescence, Spectromicroscopy, Stimulated Desorption: We Need LCLS` Brightness and Time Scale; Application of High Intensity X-rays to Materials Synthesis and Processing; LCLS Optics: Selected Technological Issues and Scientific Opportunities; Possible Applications of an FEL for Materials Studies in the 60 eV to 200 eV Spectral Region.

  16. Supercontinuum as a light source for miniaturized endoscopes

    PubMed Central

    Lu, M. K.; Lin, H. Y.; Hsieh, C. C.; Kao, F. J.

    2016-01-01

    In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, including color rendering index (CRI: 72%~97%) and correlated color temperature (CCT: 3,100K~5,200K), are modified with external filters and compared with those from a LED light source (CRI~76% & CCT~6,500K). The very high spatial coherence of the supercontinuum allows high luminosity conduction through a single multimode fiber (core size~400μm), whose distal end tip is attached with a diffussion tip to broaden the solid angle of illumination (from less than 10° to more than 80°). PMID:27699102

  17. NATIONAL SYNCHROTRON LIGHT SOURCE MEDICAL PERSONNEL PROTECTION INTERLOCK

    SciTech Connect

    BUDA,S.; GMUR,N.F.; LARSON,R.; THOMLINSON,W.

    1998-11-03

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated.

  18. Observations of collective effects at the Advanced Light Source

    SciTech Connect

    Byrd, J.M.; Barry, W.; Corlett, J.N.; Fox, J.; Teytelman, D.

    1995-10-01

    We present a summary of measurements of single beam collective effects in the Advanced Light Source (ALS). We describe measurements of coupled-bunch instabilities, including some recent results using the newly commissioned feedback systems and the results of an initial search for the fast ion instability. Single bunch effects include bunch lengthening, energy spread increase, HOM loss measurements, head-tail damping rates, current dependent tune shifts, and transverse mode coupling instability threshold. The longitudinal measurements are consistent with a broadband impedance {vert_bar}{Zeta}{sub {parallel}}/{eta}{vert_bar}{sub eff} = 0.22{plus_minus}0.07 {Omega} and transverse measurements indicate broadband impedances of {Zeta}{sub y,eff} = 155 k{Omega}/m and Z{sub x,eff} = 58 k{Omega}/m.

  19. Optics, Diagnostics and Applications for Fourth-Generation Light Sources

    SciTech Connect

    Wootton, A; Barbee, T; Bionta, R; Chapman, H; Ditmire, T; Dyer, G; Kuba, J; Jankowski, A; London, R; Ryutov, R; Shepherd, R; Shlyaptsev, V; Toor, A

    2003-02-05

    The Linac Coherent Light Source (LCLS) is a 1.5 to 15 {angstrom}-wavelength free-electron laser (FEL), proposed for the Stanford Linear Accelerator Centre (SLAC). The photon output consists of high brightness, transversely coherent pulses with duration < 300 fs, together with a broad spontaneous spectrum with total power comparable to the coherent output. The output fluence, and pulse duration, pose special challenges for optical component and diagnostic designs. We first discuss the specific requirements for the initial scientific experiments, and our proposed solutions. We then describe the supporting research and development program that includes: (1) radiation field modeling, (2) experimental and theoretical material damage studies, (3) high resolution, high fluence-tolerant optical design, fabrication, and testing, (including material manufacturing), and (4) diagnostic design and testing.

  20. A Next Generation Light Source Facility at LBNL

    SciTech Connect

    Corlett, J.N.; Austin, B.; Baptiste, K.M.; Byrd, J.M.; Denes, P.; Donahue, R.; Doolittle, L.; Falcone, R.W.; Filippetto, D.; Fournier, S.; Li, D.; Padmore, H.A.; Papadopoulos, C.; Pappas, C.; Penn, G.; Placidi, M.; Prestemon, S.; Prosnitz, D.; Qiang, J.; Ratti, A.; Reinsch, M.; Sannibale, F.; Schlueter, R.; Schoenlein, R.W.; Staples, J.W.; Vecchione, T.; Venturini, M.; Wells, R.; Wilcox, R.; Wurtele, J.; Charman, A.; Kur, E.; Zholents, A.A.

    2011-03-23

    The Next Generation Light Source (NGLS) is a design concept, under development at LBNL, for a multibeamline soft x-ray FEL array powered by a ~;;2 GeV superconducting linear accelerator, operating with a 1 MHz bunch repetition rate. The CW superconducting linear accelerator is supplied by a high-brightness, highrepetition- rate photocathode electron gun. Electron bunches are distributed from the linac to the array of independently configurable FEL beamlines with nominal bunch rates up to 100 kHz in each FEL, and with even pulse spacing. Individual FELs may be configured for EEHG, HGHG, SASE, or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format, with pulse durations ranging from sub-femtoseconds to hundreds of femtoseconds.

  1. Improving NIR snow pit stratigraphy observations by introducing a controlled NIR light source

    NASA Astrophysics Data System (ADS)

    Dean, J.; Marshall, H.; Rutter, N.; Karlson, A.

    2013-12-01

    Near-infrared (NIR) photography in a prepared snow pit measures mm-/grain-scale variations in snow structure, as reflectivity is strongly dependent on microstructure and grain size at the NIR wavelengths. We explore using a controlled NIR light source to maximize signal to noise ratio and provide uniform incident, diffuse light on the snow pit wall. NIR light fired from the flash is diffused across and reflected by an umbrella onto the snow pit; the lens filter transmits NIR light onto the spectrum-modified sensor of the DSLR camera. Lenses are designed to refract visible light properly, not NIR light, so there must be a correction applied for the subsequent NIR bright spot. To avoid interpolation and debayering algorithms automatically performed by programs like Adobe's Photoshop on the images, the raw data are analyzed directly in MATLAB. NIR image data show a doubling of the amount of light collected in the same time for flash over ambient lighting. Transitions across layer boundaries in the flash-lit image are detailed by higher camera intensity values than ambient-lit images. Curves plotted using median intensity at each depth, normalized to the average profile intensity, show a separation between flash- and ambient-lit images in the upper 10-15 cm; the ambient-lit image curve asymptotically approaches the level of the flash-lit image curve below 15cm. We hypothesize that the difference is caused by additional ambient light penetrating the upper 10-15 cm of the snowpack from above and transmitting through the wall of the snow pit. This indicates that combining NIR ambient and flash photography could be a powerful technique for studying penetration depth of radiation as a function of microstructure and grain size. The NIR flash images do not increase the relative contrast at layer boundaries; however, the flash more than doubles the amount of recorded light and controls layer noise as well as layer boundary transition noise.

  2. Swept source optical coherence microscopy using a 1310 nm VCSEL light source

    PubMed Central

    Ahsen, Osman O.; Tao, Yuankai K.; Potsaid, Benjamin M.; Sheikine, Yuri; Jiang, James; Grulkowski, Ireneusz; Tsai, Tsung-Han; Jayaraman, Vijaysekhar; Kraus, Martin F.; Connolly, James L.; Hornegger, Joachim; Cable, Alex; Fujimoto, James G.

    2013-01-01

    We demonstrate high speed, swept source optical coherence microscopy (OCM) using a MEMS tunable vertical cavity surface-emitting laser (VCSEL) light source. The light source had a sweep rate of 280 kHz, providing a bidirectional axial scan rate of 560 kHz. The sweep bandwidth was 117 nm centered at 1310 nm, corresponding to an axial resolution of 13.1 µm in air, corresponding to 8.1 µm (9.6 µm spectrally shaped) in tissue. Dispersion mismatch from different objectives was compensated numerically, enabling magnification and field of view to be easily changed. OCM images were acquired with transverse resolutions between 0.86 µm - 3.42 µm using interchangeable 40X, 20X and 10X objectives with ~600 µm x 600 µm, ~1 mm x 1 mm and ~2 mm x 2 mm field-of-view (FOV), respectively. Parasitic variations in path length with beam scanning were corrected numerically. These features enable swept source OCM to be integrated with a wide range of existing scanning microscopes. Large FOV mosaics were generated by serially acquiring adjacent overlapping microscopic fields and combining them in post-processing. Fresh human colon, thyroid and kidney specimens were imaged ex vivo and compared to matching histology sections, demonstrating the ability of OCM to image tissue specimens. PMID:23938673

  3. A comparison of new and existing light sources for the petrochemical industry

    SciTech Connect

    Borton, J.A.; Daley, K.A.

    1995-12-31

    This paper will compare current light sources with new research available for the Petrochemical Industry in the 1990`s. High lumen output, by today`s standards, is not necessarily the correct criterion for selection of light sources in process and work areas. This paper will demonstrate how the human eye reacts to various light sources both photopically (day vision) and scotopically (night vision). This comparison of light sources with the new research may change the thinking of users and designers in their selection of light sources.

  4. Quantitative phase imaging of biological cells using spatially low and temporally high coherent light source.

    PubMed

    Ahmad, Azeem; Dubey, Vishesh; Singh, Gyanendra; Singh, Veena; Mehta, Dalip Singh

    2016-04-01

    In this Letter, we demonstrate quantitative phase imaging of biological samples, such as human red blood cells (RBCs) and onion cells using narrow temporal frequency and wide angular frequency spectrum light source. This type of light source was synthesized by the combined effect of spatial, angular, and temporal diversity of speckle reduction technique. The importance of using low spatial and high temporal coherence light source over the broad band and narrow band light source is that it does not require any dispersion compensation mechanism for biological samples. Further, it avoids the formation of speckle or spurious fringes which arises while using narrow band light source. PMID:27192285

  5. Status of PEP-X Light Source Design Study

    SciTech Connect

    Bane, K.L.F.; Bertsche, K.J.; Cai, Y.; Chao, A.; Huang, X.; Jiao, Y.; Ng, C.-K.; Nosochkov, Y.; Novokhatski, A.; Rivetta, C.H.; Safranek, J.A.; Stupakov, G.V.; Wang, L.; Wang, M.-H.; Xiao, L.; Hettel, R.O.; Rabedeau, T.; /SLAC

    2011-12-14

    The SLAC Beam Physics group and other SLAC collaborators continue to study options for implementing a near diffraction-limited ring-based light source in the 2.2-km PEP-II tunnel that will serve the SSRL scientific program in the future. The study team has completed the baseline design for a 4.5-GeV storage ring having 160 pm-rad emittance with stored beam current of 1.5 A, providing >10{sup 22} brightness for multi-keV photon beams from 3.5-m undulator sources. The team has also investigated possible 5-GeV ERL configurations which, similar to the Cornell and KEK ERL plans, would have {approx}30 pm-rad emittance with 100 mA current, and {approx}10 pm-rad emittance with 25 mA or less. Now a 4.5-GeV 'ultimate' storage ring having emittance similar to the ERL and operating with {approx}200 mA is under study. An overview of the progress of the PEP-X design study and SSRL's plans for defining performance parameters that will guide the choice of ring options is presented.

  6. A two-metric proposal to specify the color-rendering properties of light sources for retail lighting

    NASA Astrophysics Data System (ADS)

    Freyssinier, Jean Paul; Rea, Mark

    2010-08-01

    Lighting plays an important role in supporting retail operations, from attracting customers, to enabling the evaluation of merchandise, to facilitating the completion of the sale. Lighting also contributes to the identity, comfort, and visual quality of a retail store. With the increasing availability and quality of white LEDs, retail lighting specifiers are now considering LED lighting in stores. The color rendering of light sources is a key factor in supporting retail lighting goals and thus influences a light source's acceptance by users and specifiers. However, there is limited information on what consumers' color preferences are, and metrics used to describe the color properties of light sources often are equivocal and fail to predict preference. The color rendering of light sources is described in the industry solely by the color rendering index (CRI), which is only indirectly related to human perception. CRI is intended to characterize the appearance of objects illuminated by the source and is increasingly being challenged because new sources are being developed with increasingly exotic spectral power distributions. This paper discusses how CRI might be augmented to better use it in support of the design objectives for retail merchandising. The proposed guidelines include the use of gamut area index as a complementary metric to CRI for assuring good color rendering.

  7. Low-Level Radio Frequency System Development for the National Synchrotron Light Source II

    SciTech Connect

    Ma,H.; Rose, J.

    2009-05-04

    The National Synchrotron Light Source-II (NSLS-II) is a new ultra-bright 3GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. The position and timing specifications of the ultra-bright photon beam imposes a set of stringent requirements on the performance of radio frequency (RF) control. In addition, commissioning and staged installation of damping wigglers and insertion devices requires the flexibility of handling varying beam conditions. To meet these requirements, a digital implementation of the LLRF is chosen, and digital serial links are planned for the system integration. The first prototype of the controller front-end hardware has been built, and is currently being tested.

  8. The Development of the Linac Coherent Light Source RF Gun

    SciTech Connect

    Dowell, David H.; Jongewaard, Erik; Lewandowski, James; Limborg-Deprey, Cecile; Li, Zenghai; Schmerge, John; Vlieks, Arnold; Wang, Juwen; Xiao, Liling; /SLAC

    2008-09-24

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of

  9. Physiological and genetic characterization of plant growth and gravitropism in LED light sources

    NASA Technical Reports Server (NTRS)

    Deitzer, Gerald F.

    1994-01-01

    Among the many problems of growing plants in completely controlled environments, such as those anticipated for the space station and the CELSS program, is the need to provide light that is both adequate for photosynthesis and of proper quality for normal growth and development. NASA scientists and engineers have recently become interested in the possibility of utilizing densely packed, solid state, light emitting diodes (LED's) as a source for this light. Unlike more conventional incandescent or electrical discharge lamps, these sources are highly monochromatic and lack energy in spectral regions thought to be important for normal plant development. In addition, a recent observation by NASA scientist has suggested that infra-red LED's, that are routinely used as photographic safelights for plants grown in darkness, may interact with the ability of plants to detect gravity. In order to establish how plants respond to light from these LED light sources we carried out a series of experiments with known pigment mutants of the model mustard plant, Arabidopsis thaliana, growing in either a gravity field or on a clinostat to simulate a micro-gravity environment. Results indicate that only red light from the 665 nm LED's disrupts the ability of normal wildtype seedlings to detect a gravity stimulus. There was no consistent effect found for the far-red (735 nm) LED's or either of the infrared (880 nm or 935 nm) LED sources but both showed some effect in one or more of the genotypes tested. Of these five members of the phytochrome multigene family in Arabidopsis, only the phytochrome B pigment mutant (hy3) lacked the ability to detect gravity under all conditions. There was no effect of either micro-gravity (clinostat) or the infra-red LED's on the light induced inhibition of hypocotyl elongation. Measurements of the pigment phytochrome in oats also showed no photoconversion by 15 min irradiations with the infra-red LED's. We conclude that phytochrome B is required for the

  10. Feasibility of ultraviolet-light-emitting diodes as an alternative light source for photocatalysis.

    PubMed

    Levine, Lanfang H; Richards, Jeffrey T; Coutts, Janelle L; Soler, Robert; Maxik, Fred; Wheeler, Raymond M

    2011-09-01

    The objective of this study was to determine whether ultraviolet-light-emitting diodes (UV-LEDs) could serve as an efficient photon source for heterogeneous photocatalytic oxidation (PCO). An LED module consisting of 12 high-power UV-A (lambda max = 365 nm) LEDs was designed to be interchangeable with a UV-A fluorescent black light blue (BLB) lamp for a bench scale annular reactor packed with silica-titania composite (STC) pellets. Lighting and thermal properties of the module were characterized to assess its uniformity and total irradiance. A forward current (I(F)) of 100 mA delivered an average irradiance of 4.0 mW cm(-2) at a distance of 8 mm, which is equivalent to the maximum output of the BLB, but the irradiance of the LED module was less uniform than that of the BLB. The LED and BLB reactors were tested for the oxidization of ethanol (50 ppm(v)) in a continuous-flow-through mode with 0.94 sec residence time. At the same average irradiance, the UV-A LED reactor resulted in a lower CO2 production rate (19.8 vs. 28.6 nmol L(-1) s(-1)), lower ethanol removal (80% vs. 91%), and lower mineralization efficiency (28% vs. 44%) than the UV-A BLB reactor. Ethanol mineralization was enhanced with the increase of the irradiance at the catalyst surface. This result suggests that reduced ethanol mineralization in the LED reactor relative to the BLB reactor at the same average irradiance could be attributed to the nonuniform irradiance over the photocatalyst, that is, a portion of the catalyst was exposed to less than the average irradiance. The potential of UV-A LEDs may be fully realized by optimizing the light distribution over the catalyst and utilizing their instantaneous "on" and "off" feature for periodic irradiation. Nevertheless, our results also showed that the current UV-A LED module had the same wall plug efficiency (WPE) of 13% as that of the UV-A BLB, demonstrating that UV-A LEDs are a viable photon source both in terms of WPE and PCO efficiency. PMID:22010378

  11. Feasibility of Ultraviolet Light Emitting Diodes as an Alternative Light Source for Photocatalysis

    NASA Technical Reports Server (NTRS)

    Levine, Langanf H.; Richards, Jeffrey T.; Soler, Robert; Maxik, Fred; Coutts, Janelle; Wheeler, Raymond M.

    2011-01-01

    The objective of this study was to determine whether ultraviolet light emitting diodes (UV-LEDs) could serve as an alternative photon source efficiently for heterogeneous photocatalytic oxidation (PCO). An LED module consisting of 12 high-power UV-A LEDs was designed to be interchangeable with a UV-A fluorescent black light blue (BLB) lamp in a Silica-Titania Composite (STC) packed bed annular reactor. Lighting and thermal properties were characterized to assess the uniformity and total irradiant output. A forward current of (I(sub F)) 100 mA delivered an average irradiance of 4.0 m W cm(exp -2), which is equivalent to the maximum output of the BLB, but the irradiance of the LED module was less uniform than that of the BLB. The LED- and BLB-reactors were tested for the oxidization of 50 ppmv ethanol in a continuous flow-through mode with 0.94 sec space time. At the same irradiance, the UV-A LED reactor resulted in a lower PCO rate constant than the UV-A BLB reactor (19.8 vs. 28.6 nM CO2 sec-I), and consequently lower ethanol removal (80% vs. 91%) and mineralization efficiency (28% vs. 44%). Ethanol mineralization increased in direct proportion to the irradiance at the catalyst surface. This result suggests that reduced ethanol mineralization in the LED- reactor could be traced to uneven irradiance over the photocatalyst, leaving a portion of the catalyst was under-irradiated. The potential of UV-A LEDs may be fully realized by optimizing the light distribution over the catalyst and utilizing their instantaneous "on" and "off' feature for periodic irradiation. Nevertheless, the current UV-A LED module had the same wall plug efficiency (WPE) of 13% as that of the UV-A BLB. These results demonstrated that UV-A LEDs are a viable photon source both in terms of WPE and PCO efficiency.

  12. Opto-thermal study of cooling strategies for high-luminance white-light solid-state sources

    NASA Astrophysics Data System (ADS)

    Correia, António; Hanselaer, Peter; Meuret, Youri

    2016-06-01

    Solid-state sources have become ubiquitous is many lighting applications. For general lighting, phosphors are typically employed to produce white light from the narrowband light emitted from solid-state sources. As the optical output power from solid-state sources keeps increasing, increasingly higher luminance can be obtained, which, unfortunately, also increases the phosphor's temperature. These materials' colour conversion potential, encoded by the quantum yield, has complex dependencies with temperature. To obtain an accurate assessment of the performance of a high-luminance white light source configuration based on individual solid-state sources, it is imperative to accurately model the temperature distribution inside the phosphor material and consider the effect of temperature on the quantum yield of the phosphor. In addition, the feedback of the varying quantum yield on the generated heat inside the phosphor should also be considered. An opto-thermal framework has been previously proposed to accurately simulate the opto-thermal effects in phosphors when designing lighting systems. In this paper, this framework is applied to a novel optical configuration to investigate thermal bottlenecks and test cooling strategies to avoid them. For the specific configuration tested, using an active cooling strategy and concentrating the laser light on the phosphor region with the best thermal dissipation proved to be the best solutions.

  13. Optically stabilized mercury short-arc lamp as UV light source for microscopy

    NASA Astrophysics Data System (ADS)

    Heynen, Susanne; Gough, David A.; Price, Jeffrey H.

    1997-05-01

    For certain applications in microscopy, mercury vapor short arc lamps are utilized as UV-light sources because of their high intensity and their road spectrum. Unfortunately, they are also very unstable. Especially for single wavelength fluorescence image cytometry, there is a need for a stable, high intensity light source. Substantially improved stability was achieved using optical feedback and fiberoptic scrambling. The system uses a photodiode to monitor the light intensity, and feeds the readout back to a controller. The controller compares this readout to a preset reference voltage and adjusts the lamp supply current accordingly. The optical fiber scrambles the light to correct the effects of arc wander. Preliminary results of performance tests of this system show a coefficient of variation (CV) of less than 0.1 percent over 20 hours at a sample frequency of 30 Hz. This CV is a factor of 30 better than a conventional current stabilized mercy vapor short arc lamp. Scrambled optical feedback is a necessary addition for systems with mercury short arc lamps, especially for image fluorometry applications.

  14. Handling high data rate detectors at Diamond Light Source

    NASA Astrophysics Data System (ADS)

    Pedersen, U. K.; Rees, N.; Basham, M.; Ferner, F. J. K.

    2013-03-01

    An increasing number of area detectors, in use at Diamond Light Source, produce high rates of data. In order to capture, store and process this data High Performance Computing (HPC) systems have been implemented. This paper will present the architecture and usage for handling high rate data: detector data capture, large volume storage and parallel processing. The EPICS area Detector frame work has been adopted to abstract the detectors for common tasks including live processing, file format and storage. The chosen data format is HDF5 which provides multidimensional data storage and NeXuS compatibility. The storage system and related computing infrastructure include: a centralised Lustre based parallel file system, a dedicated network and a HPC cluster. A well defined roadmap is in place for the evolution of this to meet demand as the requirements and technology advances. For processing the science data the HPC cluster allow efficient parallel computing, on a mixture of ×86 and GPU processing units. The nature of the Lustre storage system in combination with the parallel HDF5 library allow efficient disk I/O during computation jobs. Software developments, which include utilising optimised parallel file reading for a variety of post processing techniques, are being developed in collaboration as part of the Pan-Data EU Project (www.pan-data.eu). These are particularly applicable to tomographic reconstruction and processing of non crystalline diffraction data.

  15. Studying compressed matter physics at the Linac Coherent Light Source

    NASA Astrophysics Data System (ADS)

    Glenzer, Siegfried; Fletcher, Luke; HED science, SLAC National Accelerator Laboratory Team; Lawrence Berkeley Laboratory Team; Lawrence Livermore National Laboratory Team

    2015-03-01

    With the advent of the Matter in Extreme Conditions instrument at the Linac Coherent Light Source a world-unique experimental capability has become available to study the physics of dynamically compressed solids. Our new high-energy-density science program at SLAC is aimed to take advantage of x-ray pulses with the highest peak brightness available today. In a single shot, the x-ray beam delivers 1012 x-ray photons in 50 fs focused to a spot of order 1 μm. This capability allows us to measure plasmons and to visualize the density and pressure evolution across melt lines by resolving correlations at distances comparable to atomic scales. Our data allow direct determination of pressure for validating theoretical models for the thermodynamics at high pressure. We will show how LCLS data test our theoretical models of compressed matter and will discuss future plans for the study of hot and dense matter. This work was supported by DOE Office of Science, Fusion Energy Science under FWP 100182.

  16. Vacuum system for the LBL advanced light source (ALS)

    SciTech Connect

    Kennedy, K.

    1988-05-01

    A 1.5 to 1.9 GeV synchrotron light source is being built at LBL. The vacuum system is designed to permit all synchrotron photons on the median plane to escape the electron channel and go into an antechamber through a 10 mm high slot. This slot offers effective RF isolation between the electron duct and the antechamber. All unused synchrotron photons within a few mrad of the median plane will be stopped by 96 nearly horizontal absorbers located in the antechamber. The gas, generated by the photons hitting the absorbers, will be directed down to reactive titanium surfaces. Twelve 10 meter long vessels constitute the vacuum chambers for all the lattice magnets. Each chamber will be machined from two thick plates of 5083-H321 aluminum and welded at the perimeter. The nominal wall thickness of the vacuum chamber is 40 mm, which makes it possible to machine a flange into the chamber without the use of welding. 5 refs., 5 figs.

  17. Single-layer mirrors for advanced research light sources

    SciTech Connect

    Stoermer, M.; Horstmann, C.; Siewert, F.; Hertlein, F.; Matiaske, M.; Wiesmann, J.; Gaudin, J.

    2010-06-23

    X-ray mirrors are needed for beam guidance, beam alignment and monochromatisation at third-generation synchrotron light sources (PETRA III) and forthcoming Free-Electron Lasers (LCLS, European XFEL). Amorphous carbon coatings are currently used as total reflection mirrors at FLASH to guide the photon beam to the various beamlines. These coatings were prepared by means of magnetron sputtering. The new GKSS sputtering facility for the deposition of single and multilayer mirrors with a length of up to 1500 mm and a width of up to 120 mm is in operation. In this contribution we present the results of this new deposition system. A major advantage is that it is now possible to prepare one, two or more mirrors with similar properties over the whole deposition length. The mirror properties were investigated by means of X-ray reflectometry and interference microscopy. The performance of the mirrors is analyzed, considering X-ray reflectivity, film thickness and surface roughness. The uniformity of these properties over the whole deposition length of 1500 mm is demonstrated. The results obtained will be discussed and compared with former results.

  18. Beam-based Feedback for the Linac Coherent Light Source

    SciTech Connect

    Fairley, D.; Allison, S.; Chevtsov, S.; Chu, P.; Decker, F.J.; Emma, P.; Frisch, J.; Himel, T.; Kim, K.; Krejcik, P.; Loos, H.; Lahey, T.; Natampalli, P.; Peng, S.; Rogind, D.; Shoaee, H.; Straumann, T.; Williams, E.; White, G.; Wu, J.; Zelazney, M.; /SLAC

    2010-02-11

    Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6 x 6 longitudinal feedback loop, and a loop to maintain the electron bunch charge were successfully prototyped in MATLAB for the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 30Hz. In the final commissioning phase of LCLS the beam will be operating at up to 120Hz. In order to run the feedback loops at beam rate, the feedback loops will be implemented in EPICS IOCs with a dedicated ethernet multi-cast network. This paper will discuss the design of the beam-based Fast Feedback System for LCLS. Topics include MATLAB feedback prototyping, algorithm for 120Hz feedback, network design for fast data transport, actuator and sensor design for single-pulse control and sensor readback, and feedback configuration and runtime control.

  19. Final Report, Photocathodes for High Repetition Rate Light Sources

    SciTech Connect

    Ben-Zvi, Ilan

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-antimonide cathodes b) Development and testing of a diamond amplifier for photocathodes c) Tests of both cathodes in superconducting RF photoguns and copper RF photoguns

  20. Alternate Tunings for the Linac Coherent Light Source Photoinjector

    SciTech Connect

    Limborg-Deprey, C.; Emma, P.; /SLAC

    2006-03-17

    The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the 1 nC case. In the second half of this paper, we discuss optimum laser pulse shapes. We demonstrate that the benefits of the ellipsoidal shapes seem to be important enough so that serious investigations should be carried out in the production of such pulses.

  1. The Potential of an Ultimate Storage Ring for Future Light Sources

    SciTech Connect

    Bei, M; Cai, Y; Elleaume, P; Gerig, R; Harkay, K; Emery, L; Hutton, A; Hettel, R; Nagaoka, R; Robin, D; Steier, C

    2010-10-01

    This paper is the report of the working group on Ultimate Storage Rings at the Department of Energy's Basic Energy Sciences Workshop on Physics of Future Light Sources, which took place in Gaithersburg, Maryland on September 15–17, 2009. In this report we address the accelerator design issues related to the next generation of storage ring light sources, deemed “ultimate” storage rings. In our estimation, storage rings have the potential to provide an increase in photon brightness and coherent flux that is two orders of magnitude above that projected for rings currently under construction. In addition to photon brightness and coherent flux, we discuss other directions, such as shorter pulses, tailored bunches, and partial lasing, in which rings could evolve. For the most part we envision ultimate storage rings as an evolutionary advance from existing rings that faces no fundamental technological obstacles. Nevertheless we identify several important areas of R&D that should be pursued to enable the realization of the full potential of ultimate ring light sources.

  2. Time Resolved X-ray Magnetic Circular Dichroism at the Linac Coherent Light Source

    NASA Astrophysics Data System (ADS)

    Schlotter, W.; Higley, D.; Jal, E.; Dakovski, G.; Yuan, E.; MacArthur, J.; Lutman, A.; Hirsch, K.; Granitzka, P.; Chen, Z.; Coslovich, G.; Hoffman, M.; Mitra, A.; Reid, A.; Hart, P.; Nuhn, H.-D.; Duerr, H.; Arenholz, E.; Shafer, P.; Dennes, P.; Joseph, J.; Guyader, L.; Tsukamoto, A.

    We demonstrate ultrafast time resolved X-ray Magnetic Circular Dichroism on optically switchable GdFeCo thin film samples. This method extends the element specificity of time resolved x-ray absorption spectroscopy to characterize the evolution of electron spin and orbital angular momenta. These measurements were enabled by a recent upgrade at the Linac Coherent Light Source (LCLS) to generate circularly polarized x-rays. Additionally these measurements were enhanced by new detection systems that benefit all x-ray absorption spectroscopy experiments performed in transmission. Consequently static XMCD data are in excellent agreement with similar measurements at synchrotron light sources. The LCLS is an x-ray free electron laser user facility accessible via a peer-reviewed proposal process. Acknowledgement: The Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515.

  3. Shifted excitation resonance Raman difference spectroscopy using a microsystem light source at 488 nm

    NASA Astrophysics Data System (ADS)

    Maiwald, M.; Sowoidnich, K.; Schmidt, H.; Sumpf, B.; Erbert, G.; Kronfeldt, H.-D.

    2010-04-01

    Experimental results in shifted excitation resonance Raman difference spectroscopy (SERRDS) at 488 nm will be presented. A novel compact diode laser system was used as excitation light source. The device is based on a distributed feedback (DFB) diode laser as a pump light source and a nonlinear frequency doubling using a periodically poled lithium niobate (PPLN) waveguide crystal. All elements including micro-optics are fixed on a micro-optical bench with a footprint of 25 mm × 5 mm. An easy temperature management of the DFB laser and the crystal was used for wavelength tuning. The second harmonic generation (SHG) provides an additional suppression of the spontaneous emission. Raman spectra of polystyrene demonstrate that no laser bandpass filter is needed for the Raman experiments. Resonance-Raman spectra of the restricted food colorant Tartrazine (FD&C Yellow 5, E 102) in distilled water excited at 488 nm demonstrate the suitability of this light source for SERRDS. A limit of detection (LOD) of 0.4 μmol.l-1 of E102 enables SERRDS at 488 nm for trace detection in e.g. food safety control as an appropriate contactless spectroscopic technique.

  4. Spectra of Three Light Sources with a CD.

    ERIC Educational Resources Information Center

    Zanetti, Vittorio; Harris, John

    1993-01-01

    Uses a compact disc (CD) as a grating in spectroscopy experiments. Suggests using the CD with fluorescent tubes, compact fluorescent light bulbs, incandescent filament light bulbs, and sodium and mercury vapor lamps. Discusses environmental and economic aspects of fluorescent lighting. (MVL)

  5. High Energy Density Science at the Linac Coherent Light Source

    SciTech Connect

    Lee, R W

    2007-10-19

    High energy density science (HEDS), as a discipline that has developed in the United States from National Nuclear Security Agency (NNSA)-sponsored laboratory research programs, is, and will remain, a major component of the NNSA science and technology strategy. Its scientific borders are not restricted to NNSA. 'Frontiers in High Energy Density Physics: The X-Games of Contemporary Science' identified numerous exciting scientific opportunities in this field, while pointing to the need for a overarching interagency plan for its evolution. Meanwhile, construction of the first x-ray free-electron laser, the Office-of-Science-funded Linear Coherent Light Source-LCLS: the world's first free electron x-ray laser, with 100-fsec time resolution, tunable x-ray energies, a high rep rate, and a 10 order-of-magnitude increase in brightness over any other x-ray source--led to the realization that the scientific needs of NNSA and the broader scientific community could be well served by an LCLS HEDS endstation employing both short-pulse and high-energy optical lasers. Development of this concept has been well received in the community. NNSA requested a workshop on the applicability of LCLS to its needs. 'High Energy Density Science at the LCLS: NNSA Defense Programs Mission Need' was held in December 2006. The workshop provided strong support for the relevance of the endstation to NNSA strategic requirements. The range of science that was addressed covered a wide swath of the vast HEDS phase space. The unique possibilities provided by the LCLS in areas of intense interest to NNSA Defense Programs were discussed. The areas of focus included warm dense matter and equations of state, hot dense matter, and behavior of high-pressure materials under conditions of high strain-rate and extreme dynamic loading. Development of new and advanced diagnostic techniques was also addressed. This report lays out the relevant science, as brief summaries (Ch. II), expanded descriptions (Ch. V), and a

  6. LIGHT SOURCE: Spot size diagnostics for flash radiographic X-ray sources at LAPA

    NASA Astrophysics Data System (ADS)

    Li, Cheng-Gang; Li, Qin; Shi, Jin-Shui; Deng, Jian-Jun

    2009-06-01

    Spot size is one of the parameters to characterize the performance of a radiographic X-ray source. It determines the degree of blurring due to magnification directly. In recent years, a variety of measurement methods have been used to diagnose X-ray spot size at Laboratory of Accelerator Physics and Application (LAPA). Computer simulations and experiments showed that using a rolled-edge to measure the spot size are more accurate, and the intensity distribution of X-ray source was obtained by a device with a square aperture. Experimental and simulation results on a flash X-ray source at our laboratory are presented and discussed in this paper. In addition, a new method for time resolved diagnostics of X-ray spot size is introduced too.

  7. Shining Light on Copper: Unique Opportunities for Visible-Light-Catalyzed Atom Transfer Radical Addition Reactions and Related Processes.

    PubMed

    Reiser, Oliver

    2016-09-20

    Visible-light photoredox catalysis offers exciting opportunities to achieve challenging carbon-carbon bond formations under mild and ecologically benign conditions. Desired features of photoredox catalysts are photostability, long excited-state lifetimes, strong absorption in the visible region, and high reduction or oxidation potentials to achieve electron transfer to substrates, thus generating radicals that can undergo synthetic organic transformations. These requirements are met in a convincing way by Ru(II)(phenanthroline)3- and Ir(III)(phenylpyridine)3-type complexes and, as a low-cost alternative, by organic dyes that offer a metal-free catalyst but suffer in general from lower photostability. Cu(I)(phenanthroline)2 complexes have been recognized for more than 30 years as photoresponsive compounds with highly negative Cu(I)* → Cu(II) oxidation potentials, but nevertheless, they have not been widely considered as suitable photoredox catalysts, mainly because their excited lifetimes are shorter by a factor of 5 to 10 compared with Ru(II) and Ir(III) complexes, their absorption in the visible region is weak, and their low Cu(II) → Cu(I) reduction potentials might impede the closure of a catalytic cycle for a given process. Contrasting again with Ru(II)L3 and Ir(III)L3 complexes, Cu(I)L2 assemblies undergo more rapid ligand exchange in solution, thus potentially reducing the concentration of the photoactive species. Focusing on atom transfer radical addition (ATRA) reactions and related processes, we highlight recent developments that show the utility of Cu(I)(phenanthroline)2 complexes as photoredox catalysts, demonstrating that despite their short excited-state lifetimes and weak absorption such complexes are efficient at low catalyst loadings. Moreover, some of the inherent disadvantages stated above can even be turned to advantages: (1) the low Cu(II) → Cu(I) reduction potential might efficiently promote reactions via a radical chain pathway, and (2

  8. Spectral emission properties of a LPP light source in the sub-200nm range for wafer inspection applications

    NASA Astrophysics Data System (ADS)

    Gambino, Nadia; Rollinger, Bob; Hudgins, Duane; Abhari, Reza; Abreau, F.

    2015-03-01

    In this work, the spectral emission proprieties of a droplet-based laser-produced plasma are investigated in the VUV range. These studies are performed with a spectrograph operating from 30 nm to 180 nm at a spectral resolution of 0.1 nm. The emission spectra are recorded for different droplet-based metal fuels such as tin, indium and gallium in the presence of different background gas pressure levels. The experimental results are relevant for alternative light sources that would be needed for future wafer inspection tools. In addition, the experimental results help to determine the Out- Of-Band (OOB) radiation emission of the EUV source. By tuning the type of fuel, the laser energies and the background gas, the LPP light source shows good capabilities to be operated as a tunable light source that covers a spectral emission range from the EUV to the sub-200 nm range.

  9. The X-ray correlation spectroscopy instrument at the Linac Coherent Light Source

    SciTech Connect

    Alonso-Mori, Roberto; Caronna, Chiara; Chollet, Matthieu; Curtis, Robin; Damiani, Daniel S.; Defever, Jim; Feng, Yiping; Flath, Daniel L.; Glownia, James M.; Lee, Sooheyong; Lemke, Henrik T.; Nelson, Silke; Bong, Eric; Sikorski, Marcin; Song, Sanghoon; Srinivasan, Venkat; Stefanescu, Daniel; Zhu, Diling; Robert, Aymeric

    2015-03-03

    The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4–25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. In addition, a description of the instrument capabilities and recent achievements is presented.

  10. SUNY beamline facilities at the National Synchrotron Light Source (Final Report)

    SciTech Connect

    Coppens, Philip

    2003-06-22

    The DOE sponsored SUNY synchrotron project has involved close cooperation among faculty at several SUNY campuses. A large number of students and postdoctoral associates have participated in its operation which was centered at the X3 beamline of the National Synchrotron Light Source at Brookhaven National Laboratory. Four stations with capabilities for Small Angle Scattering, Single Crystal and Powder and Surface diffraction and EXAFS were designed and operated with capability to perform experiments at very low as well as elevated temperatures and under high vacuum. A large amount of cutting-edge science was performed at the facility, which in addition provided excellent training for students and postdoctoral scientists in the field.

  11. The X-ray correlation spectroscopy instrument at the Linac Coherent Light Source

    DOE PAGES

    Alonso-Mori, Roberto; Caronna, Chiara; Chollet, Matthieu; Curtis, Robin; Damiani, Daniel S.; Defever, Jim; Feng, Yiping; Flath, Daniel L.; Glownia, James M.; Lee, Sooheyong; et al

    2015-03-03

    The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4–25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. In addition, a description of the instrument capabilities and recent achievements is presented.

  12. Carbon materials as additives to WO3 for an enhanced conversion of simulated solar light

    NASA Astrophysics Data System (ADS)

    Carmona, Rocío; Velasco, Leticia; Laurenti, Enzo; Maurino, Valter; Ania, Conchi

    2016-02-01

    We have explored the impact of the incorporation of nanoporous carbons as additives to tungsten oxide on the photocatalytic degradation of two recalcitrant pollutants: rhodamine B and phenol, under simulated solar light. For this purpose, WO3/carbon mixtures were prepared using three carbon materials with different properties (in terms of porosity, structural order and surface chemistry). Despite the low carbon content used (2 wt. %), a significant increase in the photocatalytic performance of the semiconductor was observed for all the catalysts. Moreover, the influence of the carbon additive on the performance of the photocatalysts was found to be very different for the two pollutants. Carbon additives of hydrophobic nature increased the photodegradation yield of phenol compared to bare WO3, likely due to the higher affinity and stronger interactions of phenol molecules towards basic nanoporous carbons. Oppositely, the use of acidic carbon additives led to higher rhodamine B conversions due to increased acidity of the WO3/carbon mixtures and the stronger affinity of the pollutant for acidic catalyst’s surfaces. As a result, the photooxidation of rhodamine B is favored by means of a coupled (photosensitized and photocatalytic) degradation mechanism. All these results highlight the importance of favoring the interactions of the pollutant with the catalyst’s surface through a detailed design of the features of the photocatalyst.

  13. Advanced Light Source activity report 1996/97

    SciTech Connect

    1997-09-01

    Ten years ago, the Advanced Light Source (ALS) existed as a set of drawings, calculations, and ideas. Four years ago, it stored an electron beam for the first time. Today, the ALS has moved from those ideas and beginnings to a robust, third-generation synchrotron user facility, with eighteen beam lines in use, many more in planning or construction phases, and hundreds of users from around the world. Progress from concepts to realities is continuous as the scientific program, already strong in many diverse areas, moves in new directions to meet the needs of researchers into the next century. ALS staff members who develop and maintain the infrastructure for this research are similarly unwilling to rest on their laurels. As a result, the quality of the photon beams the authors deliver, as well as the support they provide to users, continues to improve. The ALS Activity Report is designed to share the results of these efforts in an accessible form for a broad audience. The Scientific Program section, while not comprehensive, shares the breadth, variety, and interest of recent research at the ALS. (The Compendium of User Abstracts and Technical Reports provides a more comprehensive and more technical view.) The Facility Report highlights progress in operations, ongoing accelerator research and development, and beamline instrumentation efforts. Although these Activity Report sections are separate, in practice the achievements of staff and users at the ALS are inseparable. User-staff collaboration is essential as they strive to meet the needs of the user community and to continue the ALS's success as a premier research facility.

  14. Dielectric Wakefield Accelerator to drive the future FEL Light Source.

    SciTech Connect

    Jing, C.; Power, J.; Zholents, A. )

    2011-04-20

    X-ray free-electron lasers (FELs) are expensive instruments and a large part of the cost of the entire facility is driven by the accelerator. Using a high-energy gain dielectric wake-field accelerator (DWA) instead of the conventional accelerator may provide a significant cost saving and reduction of the facility size. In this article, we investigate using a collinear dielectric wakefield accelerator to provide a high repetition rate, high current, high energy beam to drive a future FEL x-ray light source. As an initial case study, a {approx}100 MV/m loaded gradient, 850 GHz quartz dielectric based 2-stage, wakefield accelerator is proposed to generate a main electron beam of 8 GeV, 50 pC/bunch, {approx}1.2 kA of peak current, 10 x 10 kHz (10 beamlines) in just 100 meters with the fill factor and beam loading considered. This scheme provides 10 parallel main beams with one 100 kHz drive beam. A drive-to-main beam efficiency {approx}38.5% can be achieved with an advanced transformer ratio enhancement technique. rf power dissipation in the structure is only 5 W/cm{sup 2} in the high repetition rate, high gradient operation mode, which is in the range of advanced water cooling capability. Details of study presented in the article include the overall layout, the transform ratio enhancement scheme used to increase the drive to main beam efficiency, main wakefield linac design, cooling of the structure, etc.

  15. National Synchrotron Light Source medical personnel protection interlock

    SciTech Connect

    Buda, S.; Gmuer, N.F.; Larson, R.; Thomlinson, W.

    1998-11-01

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated. This MPPI report is organized such that the level of detail changes from a general overview to detailed engineering drawings of the hardware system. The general overview is presented in Section 1.0, MPPI Operational Mode and Procedures. The various MPPI components are described in detail in Section 2.0. Section 3.0 presents some simplified logic diagrams and accompanying text. This section was written to allow readers to become familiar with the logic system without having to work through the entire set of detailed engineering drawings listed in the Appendix. Detailed logic specifications are given in Section 4.0. The Appendix also contains copies of the current MPPI interlock test procedures for Setup and Patient Modes.

  16. EDITORIAL: Extreme Ultraviolet Light Sources for Semiconductor Manufacturing

    NASA Astrophysics Data System (ADS)

    Attwood, David

    2004-12-01

    issue of available EUV power from electrical discharge pinch plasmas and laser produced plasmas, including the roots of these requirements, the relevant plasma and radiation physics, and current state-of-the-art commercial technology. In the first paper of the cluster, Vadim Banine and Roel Moors of ASML in the Netherlands provide a detailed review of the required EUV power based on an economically viable throughput of one hundred 300 mm diameter wafers per hour, projected resist sensitivity, number of finite reflectivity multilayer coated surfaces and their collective spectral bandwidth, and a collection solid angle set by optical phase-space constraints and plasma source size. Thomas Krücken and his colleagues from Philips and the Fraunhofer Institute in Aachen present a theoretical model of radiation generation and transport based on model density and temperature profiles in an electrical discharge plasma, providing valuable insights into radiation physics and the limits to achievable power. Kenneth Fahy and his colleagues at UCD in Dublin and NIST in the US, in their paper, describe in detail atomic physics calculations of emission from relevant lines and unresolved transition arrays (UTAs) of candidate xenon and tin ions, each of which radiate strongly within the acceptance bandwidth of the multilayer coatings. The different elements, Xe and Sn, however, raise significantly different implications for source debris production and thus of requisite debris mitigation requirements. Björn Hannson and Hans Hertz of KTH University in Stockholm present a substantial review of laser produced plasmas for the EUV, including those based on liquid jet technologies, leading to a path of mass limited target material, and significant stand-off distance from the solid nozzle, which maximize EUV power generation while minimizing debris production. In addition to an extensive review of EUV source related literature, they describe experiments with laser irradiated droplets and

  17. Polymer and small molecule based hybrid light source

    DOEpatents

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  18. Multi-channel LED light source for fluorescent agent aided minimally invasive surgery.

    PubMed

    Ren, Jiacheng; Venugopalan, Janani; Xu, Jian; Kairdolf, Brad; Durfee, Robert; Wang, May D

    2014-01-01

    Cancer is one of the most common and deadly diseases around the world. Amongst all the different treatments of cancer such as surgery, chemotherapy and radiation therapy, surgical resection is the most effective. Successful surgeries greatly rely on the detection of the accurate tumor size and location, which can be enhanced by contrast agents. Commercial endoscope light sources, however, offer only white light illumination. In this paper, we present the development of a LED endoscope light source that provides 2 light channels plus white light to help surgeons to detect a clear tumor margin during minimally invasive surgeries. By exciting indocyanine green (ICG) and 5-Aminolaevulinic acid (ALA)-induced protoporphyrin IX (PPIX), the light source is intended to give the user a visible image of the tumor margin. This light source is also portable, easy to use and costs less than $300 to build. PMID:25571589

  19. Multi-Channel LED Light Source for Fluorescent Agent Aided Minimally Invasive Surgery

    PubMed Central

    Ren, Jiacheng; Venugopalan, Janani; Xu, Jian; Kairdolf, Brad; Durfee, Robert; Wang, May D.

    2016-01-01

    Cancer is one of the most common and deadly diseases around the world. Amongst all the different treatments of cancer such as surgery, chemotherapy and radiation therapy, surgical resection is the most effective. Successful surgeries greatly rely on the detection of the accurate tumor size and location, which can be enhanced by contrast agents. Commercial endoscope light sources, however, offer only white light illumination. In this paper, we present the development of a LED endoscope light source that provides 2 light channels plus white light to help surgeons to detect a clear tumor margin during minimally invasive surgeries. By exciting indocyanine green (ICG) and 5-Aminolaevulinic acid (ALA)-induced protoporphyrin IX (PPIX), the light source is intended to give the user a visible image of the tumor margin. This light source is also portable, easy to use and costs less than $300 to build. PMID:25571589

  20. Light source design for double reflection transmission-type visibility meter

    NASA Astrophysics Data System (ADS)

    Zhen, Xiaoqiong; Yang, Ling; Niu, Zhiqiang; Zeng, Qiangyu

    2015-07-01

    In this paper, a novel transmission-type visibility meter which is also named double reflection transmission-type visibility meter is introduced and developed. The novel visibility meter uses a charge coupled device (CCD) as an image acquiring unit, the CCD acquires light spot images which generated by a light source, an air extinction coefficient is calculated, and then the meteorology visibility is obtained. The light source is an important unit in this novel visibility meter, and influences the meteorology visibility calculation results. In this paper, several light source design schemes are proposed and researched. Each light source scheme is tested and the experimental results are analyzed. Finally the novel visibility meter which employs a determined light source design scheme finished a measurement result comparison experiment and the reliability and accuracy of the visibility meter are proved.

  1. A high-power incoherent light source for ultra-precise optical trapping

    NASA Astrophysics Data System (ADS)

    Schittko, Robert; Mazurenko, Anton; Greiner, Markus

    2016-05-01

    The ability to engineer arbitrary optical potentials using spatial light modulation has opened up exciting possibilities in ultracold quantum gas experiments. Yet, despite the high trap quality currently achievable, interference-induced distortions caused by scattering along the optical path continue to impede more sensitive measurements. We present a design of a high-power, spatially and temporally incoherent light source that dramatically reduces the impact of such distortions. The device is based on an array of non-lasing semiconductor emitters mounted on a single chip, whose optical output is coupled into a multi-mode fiber. The fiber is used to populate a large number of transverse modes, each of which experiences a different optical path length. This effect, combined with the small coherence length of the light, dramatically reduces the spatial coherence of the output. In addition to theoretical calculations showcasing the feasibility of this approach, we present various experimental measurements verifying the low degree of spatial coherence exhibited by the source, including a detailed analysis of the speckle contrast at the fiber end.

  2. Organic Light Emitting Device as a fluorescence spectroscopy's light source : one step towards the lab-on-a-chip device

    NASA Astrophysics Data System (ADS)

    Camou, S.; Kitamura, M.; Gouy, Jean-Philippe; Fujita, Hiroyuki; Arakawa, Yasuhiko; Fujii, Teruo

    2003-02-01

    Many papers were recently dedicated to the lab-on-a-chip applications, where all the basic elements should be integrated directly onto the microchip. The fluorescence spectroscopy is mostly used as a detection method due to its high reliability and sensitivity, but requires light source and photo-detector. For the first time, we then propose to use Organic material Light Emitting Diode (OLED) to supply a light source for the optical detection based on fluorescence spectroscopy. By combining this OLED with micro-fluidic channels patterned in PDMS layer, the integration of light source on the chip is then achieved. First, the ability of Organic Material to excite fluorescent response from dye is demonstrated. Then, some configurations are described in order to decrease the major drawbacks that have to be solved before applying such kind of devices.

  3. CaMKII in addition to MLCK contributes to phosphorylation of regulatory light chain in cardiomyocytes.

    PubMed

    Eikemo, Hilde; Moltzau, Lise Román; Hussain, Rizwan I; Nguyen, Cam H T; Qvigstad, Eirik; Levy, Finn Olav; Skomedal, Tor; Osnes, Jan-Bjørn

    2016-02-26

    The aim was to identify kinase activities involved in the phosphorylation of regulatory light chain (RLC) in situ in cardiomyocytes. In electrically stimulated rat cardiomyocytes, phosphatase inhibition by calyculin A unmasked kinase activities evoking an increase of phosphorylated RLC (P-RLC) from about 16% to about 80% after 80 min. The phosphorylation rate in cardiomyocytes was reduced by about 40% by the myosin light chain kinase (MLCK) inhibitor, ML-7. In rat ventricular muscle strips, calyculin A induced a positive inotropic effect that correlated with P-RLC levels. The inotropic effect and P-RLC elevation were abolished by ML-7 treatment. The kinase activities phosphorylating RLC in cardiomyocytes were reduced by about 60% by the non-selective kinase inhibitor staurosporine and by about 50% by the calmodulin antagonist W7. W7 eliminated the inhibitory effect of ML-7, suggesting that the cardiac MLCK is Ca(2+)/calmodulin (CaM)-dependent. The CaM-dependent kinase II (CaMKII) inhibitor KN-93 attenuated the calyculin A-induced RLC phosphorylation by about 40%, indicating a contribution from CaMKII. The residual phosphorylation in the presence of W7 indicated that also CaM-independent kinase activities might contribute. RLC phosphorylation was insensitive to protein kinase C inhibition. In conclusion, in addition to MLCK, CaMKII phosphorylates RLC in cardiomyocytes. Involvement of other kinases cannot be excluded.

  4. Continuous Digital Light Processing (cDLP): Highly Accurate Additive Manufacturing of Tissue Engineered Bone Scaffolds.

    PubMed

    Dean, David; Jonathan, Wallace; Siblani, Ali; Wang, Martha O; Kim, Kyobum; Mikos, Antonios G; Fisher, John P

    2012-03-01

    Highly accurate rendering of the external and internal geometry of bone tissue engineering scaffolds effects fit at the defect site, loading of internal pore spaces with cells, bioreactor-delivered nutrient and growth factor circulation, and scaffold resorption. It may be necessary to render resorbable polymer scaffolds with 50 μm or less accuracy to achieve these goals. This level of accuracy is available using Continuous Digital Light processing (cDLP) which utilizes a DLP(®) (Texas Instruments, Dallas, TX) chip. One such additive manufacturing device is the envisionTEC (Ferndale, MI) Perfactory(®). To use cDLP we integrate a photo-crosslinkable polymer, a photo-initiator, and a biocompatible dye. The dye attenuates light, thereby limiting the depth of polymerization. In this study we fabricated scaffolds using the well-studied resorbable polymer, poly(propylene fumarate) (PPF), titanium dioxide (TiO(2)) as a dye, Irgacure(®) 819 (BASF [Ciba], Florham Park, NJ) as an initiator, and diethyl fumarate as a solvent to control viscosity. PMID:23066427

  5. Continuous Digital Light Processing (cDLP): Highly Accurate Additive Manufacturing of Tissue Engineered Bone Scaffolds

    PubMed Central

    Dean, David; Wallace, Jonathan; Siblani, Ali; Wang, Martha O.; Kim, Kyobum; Mikos, Antonios G.; Fisher, John P.

    2012-01-01

    Highly accurate rendering of the external and internal geometry of bone tissue engineering scaffolds effects fit at the defect site, loading of internal pore spaces with cells, bioreactor-delivered nutrient and growth factor circulation, and scaffold resorption. It may be necessary to render resorbable polymer scaffolds with 50 μm or less accuracy to achieve these goals. This level of accuracy is available using Continuous Digital Light processing (cDLP) which utilizes a DLP® (Texas Instruments, Dallas, TX) chip. One such additive manufacturing device is the envisionTEC (Ferndale, MI) Perfactory®. To use cDLP we integrate a photo-crosslinkable polymer, a photo-initiator, and a biocompatible dye. The dye attenuates light, thereby limiting the depth of polymerization. In this study we fabricated scaffolds using the well-studied resorbable polymer, poly(propylene fumarate) (PPF), titanium dioxide (TiO2) as a dye, Irgacure® 819 (BASF [Ciba], Florham Park, NJ) as an initiator, and diethyl fumarate as a solvent to control viscosity. PMID:23066427

  6. Enantioselective Visible-Light-Induced Radical-Addition Reactions to 3-Alkylidene Indolin-2-ones.

    PubMed

    Lenhart, Dominik; Bauer, Andreas; Pöthig, Alexander; Bach, Thorsten

    2016-05-01

    The title compounds underwent a facile and high-yielding addition reaction (19 examples, 66-99% yield) with various N-(trimethylsilyl)methyl-substituted amines upon irradiation with visible light and catalysis by a metal complex. If the alkylidene substituent is non-symmetric and if the reaction is performed in the presence of a chiral hydrogen-bonding template, products are obtained with significant enantioselectivity (58-72% ee) as a mixture of diastereoisomers. Mechanistic studies suggest a closed catalytic cycle for the photoactive metal complex. However, the silyl transfer from the amine occurs not only to the product, but also to the substrate, and interferes with the desired chirality transfer.

  7. Shining Light on Copper: Unique Opportunities for Visible-Light-Catalyzed Atom Transfer Radical Addition Reactions and Related Processes.

    PubMed

    Reiser, Oliver

    2016-09-20

    Visible-light photoredox catalysis offers exciting opportunities to achieve challenging carbon-carbon bond formations under mild and ecologically benign conditions. Desired features of photoredox catalysts are photostability, long excited-state lifetimes, strong absorption in the visible region, and high reduction or oxidation potentials to achieve electron transfer to substrates, thus generating radicals that can undergo synthetic organic transformations. These requirements are met in a convincing way by Ru(II)(phenanthroline)3- and Ir(III)(phenylpyridine)3-type complexes and, as a low-cost alternative, by organic dyes that offer a metal-free catalyst but suffer in general from lower photostability. Cu(I)(phenanthroline)2 complexes have been recognized for more than 30 years as photoresponsive compounds with highly negative Cu(I)* → Cu(II) oxidation potentials, but nevertheless, they have not been widely considered as suitable photoredox catalysts, mainly because their excited lifetimes are shorter by a factor of 5 to 10 compared with Ru(II) and Ir(III) complexes, their absorption in the visible region is weak, and their low Cu(II) → Cu(I) reduction potentials might impede the closure of a catalytic cycle for a given process. Contrasting again with Ru(II)L3 and Ir(III)L3 complexes, Cu(I)L2 assemblies undergo more rapid ligand exchange in solution, thus potentially reducing the concentration of the photoactive species. Focusing on atom transfer radical addition (ATRA) reactions and related processes, we highlight recent developments that show the utility of Cu(I)(phenanthroline)2 complexes as photoredox catalysts, demonstrating that despite their short excited-state lifetimes and weak absorption such complexes are efficient at low catalyst loadings. Moreover, some of the inherent disadvantages stated above can even be turned to advantages: (1) the low Cu(II) → Cu(I) reduction potential might efficiently promote reactions via a radical chain pathway, and (2

  8. Tissue slides analysis using red, green, and blue LEDs as microscope light source

    NASA Astrophysics Data System (ADS)

    Pratavieira, Sebastião.; Navascues, Felipe F.; de Souza, Larissa M.; Rosa, Ramon G. T.; Kurachi, Cristina; Bagnato, Vanderlei S.

    2016-03-01

    The optical microscopy is one of the most powerful tool in the analysis of biological systems. The usual transmitted light microscope uses a white light lamp as source, what sometimes does not bring optimal results, making it necessary to introduce filters to change some illumination properties like the color temperature or the color itself. There is, of course, an intrinsic limitation on the use of filters that is the lack of an analogical control on the illumination properties and a practical limitation that depends on the number of available filters. To address this need, we developed an illumination system based on (Red, Green and Blue) RGB LEDs, were the microscope operator can control the intensity of each one independently and manually. This paper details the developed system and describes the methods used to compare quantitatively the images acquired while using the standard white light illumination and the images obtained with the developed system. To quantify the contrast, we calculated the relative population standard deviation for the intensities of each channel of the RGB image. This procedure allowed us to compare and understand the major advantages of the developed illumination system. All analysis methods have shown that a contrast enhancement can be obtained under the RGB LEDs light. The presented illumination allowed us to visualize the structures in different samples with a better contrast without the need of any additional optical filters.

  9. lightsources.org: An Internet Site for Light SourceCommunication

    SciTech Connect

    Robinson, Art

    2004-10-04

    Research at the world's accelerator- (storage-ring and linac) based light sources is one of the most dynamic and rapidly growing fields of science. It frequently results in direct benefits to society, thereby demonstrating the value of the research with very concrete examples, but this is not widely understood or appreciated outside of the immediate user community. Our growing group of light source communicators from facilities in Europe, Asia, and the Americas, inspired by the Interactions.org Web site created by high-energy (elementary-particle)physics communicators, concluded that a light source community Web site (lightsources.org) would be the best tool for establishing effective collaboration between the communications offices of the world's light sources and to maximize the impact of our efforts. We envision lightsources.org to serve as a one-stop-shopping site for information about all aspects of light sources and the research they make possible. Audiences to be served include science communicators, the press, policymakers, the light source community, the wider scientific community, the science-interested public, and students and educators. Our proposal has been sent to the world's light source facility directors by J. Murray Gibson (APS) and William G. Stirling (ESRF). As a result,light sources.org is now being supported by a growing list of facilities from Europe, North America, and Asia. We hope to launch lightsources.org before the end of 2004.

  10. [Long optical path gas detection based on MEMS infrared light source].

    PubMed

    Du, Bin-Bin; Zhang, Peng; Gao, Wen-Hong; Shi, Yun-Bo; Zhu, Lin-Quan

    2014-04-01

    According to the requirements of infrared gas sensor for the light source, a broad wavelength, high modulation frequency, low power consumption and small size MEMS infrared light source is chosen as the radiation source, whose performance meets the requirements of infrared sensing system for the light source greatly. However, the infrared light source with the lamberation radiation characteristics is a surface light source, which is still with a large numerical aperture after shaping. It is difficult to increase the detection sensitivity by using a traditional long optical gas cell in a MEMS infrared light source detection system. Based on the dual-wavelength single beam differential detection method, an integrating sphere as the gas cell for long optical path is designed, which is able to realize long optical path for high sensitivity gas detection. The physical dimension is deduced for the equivalent optical path according to the flux conservation principle in the process of light transmission, solving the calculation problem of equivalent optical path of the integrating sphere cell. Using FPGA control chip, the MEMS infrared light source is droved at high frequency modulation and the detector output signal is processed, which makes the external circuit design much simple and flexible. It turns out that 166.7 cm equivalent optical path and the minimum concentration of methane of 0.001 x 10(-6) are achieved by the use of a 5 cm diameter integrating sphere in the research, improving the sensitivity of infrared detection system greatly.

  11. X-ray micro-Tomography at the Advanced Light Source

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The X-ray micro-Tomography Facility at the Advanced Light Source has been in operation since 2004. The source is a superconducting bend magnet of critical energy 10.5KeV; photon energy coverage is 8-45 KeV in monochromatic mode, and a filtered white light option yields useful photons up to 50 KeV. A...

  12. [Long optical path gas detection based on MEMS infrared light source].

    PubMed

    Du, Bin-Bin; Zhang, Peng; Gao, Wen-Hong; Shi, Yun-Bo; Zhu, Lin-Quan

    2014-04-01

    According to the requirements of infrared gas sensor for the light source, a broad wavelength, high modulation frequency, low power consumption and small size MEMS infrared light source is chosen as the radiation source, whose performance meets the requirements of infrared sensing system for the light source greatly. However, the infrared light source with the lamberation radiation characteristics is a surface light source, which is still with a large numerical aperture after shaping. It is difficult to increase the detection sensitivity by using a traditional long optical gas cell in a MEMS infrared light source detection system. Based on the dual-wavelength single beam differential detection method, an integrating sphere as the gas cell for long optical path is designed, which is able to realize long optical path for high sensitivity gas detection. The physical dimension is deduced for the equivalent optical path according to the flux conservation principle in the process of light transmission, solving the calculation problem of equivalent optical path of the integrating sphere cell. Using FPGA control chip, the MEMS infrared light source is droved at high frequency modulation and the detector output signal is processed, which makes the external circuit design much simple and flexible. It turns out that 166.7 cm equivalent optical path and the minimum concentration of methane of 0.001 x 10(-6) are achieved by the use of a 5 cm diameter integrating sphere in the research, improving the sensitivity of infrared detection system greatly. PMID:25007612

  13. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat fiberoptic light source and... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and...

  14. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat fiberoptic light source and... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and...

  15. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat fiberoptic light source and... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and...

  16. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and throat... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat fiberoptic light source...

  17. 21 CFR 874.4350 - Ear, nose, and throat fiberoptic light source and carrier.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4350 Ear, nose, and throat fiberoptic light source and carrier. (a) Identification. An ear, nose, and throat... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat fiberoptic light source...

  18. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, R.; Tan, W.; Shi, Z.Y.

    1994-11-01

    This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 4 figs.

  19. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You

    1997-01-01

    This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor (50). An optical fiber micro-light source (50) is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors (22) in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material (60). This process allows significant control of the size of the micro light source (50). Furthermore, photo-chemically attaching an optically active material (60) enables the implementation of the micro-light source in a variety of sensor applications.

  20. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, R.; Tan, W.; Shi, Z.Y.

    1997-05-06

    This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 10 figs.

  1. Micro optical fiber light source and sensor and method of fabrication thereof

    DOEpatents

    Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You

    1994-01-01

    This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications.

  2. The use of alternate light sources in the clinical evaluation of child abuse and sexual assault.

    PubMed

    Mackenzie, Bonnie; Jenny, Carole

    2014-03-01

    Alternate light sources are devices that produce visible and invisible light at specific wavelengths to allow for enhanced visualization of fluorescent substances. These devices (which include Wood's lamp and blue light) are often used in forensics for evidence collection and can be quite useful to physicians in the medical evaluation of suspected physical or sexual assault. An understanding of the proper applications, as well as the limitations, of each alternate light source is imperative to correctly performing and interpreting medical evaluations in the emergency department. This review discusses the evidence from prospective trials in children and adults on the ability of specific alternate light sources to identify evidence of physical or sexual assault and also highlights some promising new technological adjuncts to alternate light sources that may allow for accurate dating of bruising. PMID:24589813

  3. The use of alternate light sources in the clinical evaluation of child abuse and sexual assault.

    PubMed

    Mackenzie, Bonnie; Jenny, Carole

    2014-03-01

    Alternate light sources are devices that produce visible and invisible light at specific wavelengths to allow for enhanced visualization of fluorescent substances. These devices (which include Wood's lamp and blue light) are often used in forensics for evidence collection and can be quite useful to physicians in the medical evaluation of suspected physical or sexual assault. An understanding of the proper applications, as well as the limitations, of each alternate light source is imperative to correctly performing and interpreting medical evaluations in the emergency department. This review discusses the evidence from prospective trials in children and adults on the ability of specific alternate light sources to identify evidence of physical or sexual assault and also highlights some promising new technological adjuncts to alternate light sources that may allow for accurate dating of bruising.

  4. Parallel Beam Dynamics Simulation Tools for Future Light SourceLinac Modeling

    SciTech Connect

    Qiang, Ji; Pogorelov, Ilya v.; Ryne, Robert D.

    2007-06-25

    Large-scale modeling on parallel computers is playing an increasingly important role in the design of future light sources. Such modeling provides a means to accurately and efficiently explore issues such as limits to beam brightness, emittance preservation, the growth of instabilities, etc. Recently the IMPACT codes suite was enhanced to be applicable to future light source design. Simulations with IMPACT-Z were performed using up to one billion simulation particles for the main linac of a future light source to study the microbunching instability. Combined with the time domain code IMPACT-T, it is now possible to perform large-scale start-to-end linac simulations for future light sources, including the injector, main linac, chicanes, and transfer lines. In this paper we provide an overview of the IMPACT code suite, its key capabilities, and recent enhancements pertinent to accelerator modeling for future linac-based light sources.

  5. Source Attribution of Light-absorbing Aerosols in Arctic Snow (Invited)

    NASA Astrophysics Data System (ADS)

    Hegg, D.; Warren, S. G.; Grenfell, T. C.; Doherty, S. J.; Larson, T. V.; Clarke, A. D.

    2010-12-01

    Greenland, and the Canadian high Arctic respectively, inclusion of an additional tracer species (vanillin) permitted a more definitive differentiation of biomass sources between crop and grass burning and boreal biomass burning. As with the 2007 data set, four sources were found for each respective data set (crop and grass burning, boreal biomass burning, pollution and marine). For both data sets, the crops and grass biomass burning was the main source of both BC and other LAA species, suggesting the non-BC LAA was brown carbon. Mineral dust was present in many of the snow samples but its contribution to light absorption was typically a few percent or less based on the Fe content of the samples. Depth profiles at most of the sites allowed assessment of the seasonal variation in the source strengths. The biomass burning sources dominated in the spring but pollution played a more significant (though rarely dominant) role in the fall, winter and, for Greenland, summer.

  6. SESAME - A 3rd Generation Synchrotron Light Source for the Middle East

    SciTech Connect

    Ulkue, Dincer; Rahighi, Javad; Winick, Herman

    2007-01-19

    countries. Additional funds to purchase components of the new ring and beamlines are being sought from the EU, the US, and other sources. SESAME has benefited greatly from offers by other light source facilities of equipment and training fellowships in both accelerator technology and applications of synchrotron radiation. Details of this, and other aspects of the training program, are given below. It is hoped that in the future fellowship offers will continue to be made by many light source laboratories to further increase the level of experience with accelerator technology and synchrotron light science in preparation for the start of operation of SESAME.

  7. Xylem-Transported Glucose as an Additional Carbon Source for Leaf Isoprene Formation in Quercus Robur L.

    NASA Astrophysics Data System (ADS)

    Graus, M.; Kreuzwieser, J.; Schnitzler, J.; Wisthaler, A.; Hansel, A.; Rennenberg, H.

    2003-04-01

    Isoprene is emitted from mature, photosynthesizing leaves of many plant species, particularly of trees. Current interest in understanding the biochemical and physiological mechanisms controlling isoprene formation is caused by the important role isoprene plays in atmospheric chemistry. Isoprene reacts with hydroxyl radicals (OH) thereby generating oxidizing agents such as ozone and organic peroxides. Ozone causes significant deterioration in air quality and can pose threats to human health therefore its control is a major goal in Europe and the United States. In recent years, much progress has been made in elucidating the pathways of isoprene biosynthesis. Nevertheless the regulatory mechanisms controlling isoprene emission are not completely understood. Light and temperature appear to be the main factors controlling short-term variations in isoprene emission. Exposure of plants to C-13 labeled carbon dioxide showed instantaneous assimilated carbon is the primary carbon source for isoprene formation. However, variations in diurnal and seasonal isoprene fluxes, which cannot be explained by temperature, light, and leaf development led to the suggestion that alternative carbon sources may exist contributing to isoprene emissions. The aim of the present study was to test whether xylem-transported carbohydrates act as additional sources for isoprene biosynthesis. For this purpose, [U-C-13] alpha-D-glucose was fed to photosynthesizing leaves via the xylem of Quercus robur L. seedlings and the incorporation of glucose derived C-13 into emitted isoprene was monitored in real time using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS). A rapid incorporation of C-13 from xylem-fed glucose into single (mass 70) and double (mass 71) C-13 labeled isoprene molecules was observed after a lag phase of approximately 5 to 10 minutes. This incorporation was temperature dependent and was highest (up to 13% C-13 of total carbon emitted as isoprene) at the temperature optimum of

  8. Xylem-transported Glucose as an Additional Carbon Source for Leaf Isoprene Formation in Quercus Robur L.

    NASA Astrophysics Data System (ADS)

    Graus, M.; Wisthaler, A.; Hansel, A.; Kreuzwieser, J.; Rennenberg, H.; Schnitzler, J.

    2002-12-01

    Isoprene is emitted from mature, photosynthesizing leaves of many plant species, particularly of trees. Current interest in understanding the biochemical and physiological mechanisms controlling isoprene formation is caused by the important role isoprene plays in atmospheric chemistry. Isoprene reacts with hydroxyl radicals (OH) thereby generating oxidizing agents such as ozone and organic peroxides. Ozone causes significant deterioration in air quality and can pose threats to human health therefore its control is a major goal in Europe and the United States. In recent years, much progress has been made in elucidating the pathways of isoprene biosynthesis. Nevertheless the regulatory mechanisms controlling isoprene emission are not completely understood. Light and temperature appear to be the main factors controlling short-term variations in isoprene emission. Exposure of plants to 13CO2 showed instantaneous assimilated carbon is the primary carbon source for isoprene formation. However, variations in diurnal and seasonal isoprene fluxes, which cannot be explained by temperature, light, and leaf development led to the suggestion that alternative carbon sources may exist contributing to isoprene emissions. The aim of the present study was to test whether xylem-transported carbohydrates act as additional sources for isoprene biosynthesis. For this purpose, [U-13C]α-D-glucose was fed to photosynthesizing leaves via the xylem of {Quercus} {robur} L. seedlings and the incorporation of glucose derived 13C into emitted isoprene was monitored in real time using Proton-Transfer-Reaction Mass Spectrometry (PTR-MS). A rapid incorporation of 13C from xylem-fed glucose into single (mass 70) and double (mass 71) 13C-labeled isoprene molecules was observed after a lag phase of approximately 5 to 10 minutes. This incorporation was temperature dependent and was highest (up to 13 % 13C of total carbon emitted as isoprene) at the temperature optimum of isoprene emission (40 - 42

  9. Light intensity and quality from sole-source light-emitting diodes impact growth, morphology, and nutrient content of Brassica microgreens

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Multi-layer vertical production systems using sole-source (SS) lighting can be used for microgreen production; however, traditional SS lighting can consume large amounts of electrical energy. Light-emitting diodes (LEDs) offer many advantages over conventional light sources including: high photoelec...

  10. Stray-light sources from pupil mask edges and mitigation techniques for the TPF Coronagraph

    NASA Astrophysics Data System (ADS)

    Ceperley, Daniel; Neureuther, Andrew; Miller, Marshall; Lieber, Michael; Kasdin, Jeremy

    2006-06-01

    Stray-light sources from pupil plane masks that may limit Terrestrial Planet Finder Coronagraph (TPF-C) performance are characterized 1,2 and mitigation strategies are discussed to provide a guide for future development. Rigorous vector simulation with the Finite-Difference Time-Domain (FDTD) method is used to characterize waveguiding effects in narrow openings, sidewall interactions, manufacturing tool-marks, manufacturing roughness, mask tilt, and cross-wavelength performance of thick Silicon mask structures. These effects cause stray-light that is not accounted for in scalar thin-mask diffraction theory, the most important of which are sidewall interactions, waveguiding effects in narrow openings, and tilt. These results have been used to improve the scalar thin-mask theory used to simulate the TPF-C with the Integrated Telescope Model. 3 Of particular interest are simulations of 100m thick vertical sidewall openings that model features typically found on Ripple masks 4 fabricated by Reactive Ion Etching (RIE) processes. 5 This paper contributes fundamental data for systematically modeling these effects in end-to-end system simulation. Leakage straight through the mask material varies greatly with wavelength, especially in Silicon (an attractive mask material due to the precision manufacturing techniques developed by the IC industry). Coating Silicon with 200nm of Chrome effectively mitigates the leakage without causing additional scattering. Thick-mask diffraction differs from the predictions of scalar thin-mask theory because diffraction spreading is confined by the mask's sidewalls. This confinement can make a mask opening look electro-magnetically larger or smaller than designed, by up to 3λ per vertical sidewall on a 50μm thick mask yet this can be reduced an order of magnitude by undercutting the sidewalls 20°. These confinement effects are sensitive to mask tilt (if light reaches the sidewalls) which can lead to an imbalance in stray-light sources and

  11. Precise uniform light source based on optically connected integrating spheres for optical instrument calibration

    NASA Astrophysics Data System (ADS)

    Mikheenko, Leonid; Borovytsky, Volodymyr

    2011-09-01

    The paper proposes the uniform light sources which have a form of several or multiple optically connected integrating spheres. The principal advantages of these light sources are high photometric and metrological characteristics. As a result they have good perspectives in optical radiometry and calibration of imaging systems and optical instruments. The principal field of their application is calibration of remote sensing instruments and sensitive megapixel cameras. The light source contains several (3 ... 11) primary integrating spheres of small diameters which are installed on a secondary integrating sphere of bigger diameter. The initial light sources - halogen lamps or light emitted diodes are installed inside the primary integrating spheres. These spheres are mounted on the secondary integrating sphere. The radiation comes from the primary integrating spheres to the secondary one through diaphragms which diameters can be varied. The secondary integrating sphere has an output aperture where uniform radiance emits. It is investigated the light source design with an output aperture diameter 0.2 m and 3 or 5 primary integrating spheres. It guarantees the output radiance in range from 0.01 to 1000 W/(st•m2), radiance uniformity bigger 99.5% in an output aperture, non-linearity of an output radiance control - smaller 0.1 %. The paper presents the results of theoretical and experimental research of these light sources including the techniques for radiance calculation and the recommendations for light source design. The proposed light sources can be considered as one of the best candidates for calibration of remote sensing instruments working in optical range 0.4 - 2.2 mkm. Key words: integrating sphere, light source, calibration, uniformity, radiance, remote sensing, optical instrument.

  12. Microwave Oven Experiments with Metals and Light Sources

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter; Karstadt, Detlef

    2004-01-01

    "Don't put metal objects in the microwave" is common safety advice. But why? Here we describe demonstration experiments involving placing household metallic objects in a microwave oven. These allow a better understanding of the interaction of microwaves with materials. Light bulbs and discharge lamps can also be used in instructive demonstrations.

  13. Fluorescent photography of spray droplets using a laser light source

    NASA Technical Reports Server (NTRS)

    Groeneweg, J.; Hiroyasu, H.; Sowls, R.

    1969-01-01

    Monochromatic laser emission transformed by a fluorescent process into droplet emission over a wavelength band provides high light intensities for obtaining adequate time resolution to stop droplet motion in photographic spray studies. Experiments showed that the Q-switched laser-optical harmonic generator combination produced sharp, well-exposed droplet images.

  14. Detecting an Extended Light Source through a Lens

    ERIC Educational Resources Information Center

    Litaker, E. T.; Machacek, J. R.; Gay, T. J.

    2011-01-01

    We present a Monte Carlo simulation of a cylindrical luminescent volume and a typical lens-detector system. The results of this simulation yield a graphically simple picture of the regions within the cylindrical volume from which this system detects light. Because the cylindrical volume permits large angles of incidence, we use a modification of…

  15. Stage Scenery, Machinery, and Lighting: A Guide to Information Sources.

    ERIC Educational Resources Information Center

    Stoddard, Richard

    This annotated bibliography traces the status of stage scenery and lighting, throughout the world, from the classical Greek theatre to the theatre of the 1970s, and includes references to available books, articles, pamphlets, some exhibition catalogs, and a few newspaper articles. Part one lists general references, including bibliographies and…

  16. Computation and visualization of the MacAdam limits for any lightness, hue angle, and light source

    NASA Astrophysics Data System (ADS)

    Martínez-Verdú, Francisco; Perales, Esther; Chorro, Elisabet; de Fez, Dolores; Viqueira, Valentín; Gilabert, Eduardo

    2007-06-01

    We present a systematic algorithm capable of searching for optimal colors for any lightness L* (between 0 and 100), any illuminant (D65, F2, F7, F11, etc.), and any light source reported by CIE. Color solids are graphed in some color spaces (CIELAB, SVF, DIN99d, and CIECAM02) by horizontal (constant lightness) and transversal (constant hue angle) sections. Color solids plotted in DIN99d and CIECAM02 color spaces look more spherical or homogeneous than the ones plotted in CIELAB and SVF color spaces. Depending on the spectrum of the light source or illuminant, the shape of its color solid and its content (variety of distinguishable colors, with or without color correspondence) change drastically, particularly with sources whose spectrum is discontinuous and/or very peaked, with correlated color temperature lower than 5500 K. This could be used to propose an absolute colorimetric quality index for light sources comparing the volumes of their gamuts, in a uniform color space.

  17. Playing the tricks of numbers of light sources

    NASA Astrophysics Data System (ADS)

    Chen, Huanyang; Xu, Yadong; Li, Hui; Tyc, Tomáš

    2013-09-01

    Transformation optics has demonstrated its ability to design various novel devices, for example, to change objects' sizes, positions or even shapes. This time we come to another magical manipulation: to change the numbers of sources. In this paper, we will design a new class of gradient index lenses from multivalued optical conformal mapping. We shall call them the conformal lenses. Such lenses can make one active source appear omnidirectionally as two (or many) in-phase sources, each interfering with others. As a self-interference phenomenon, this has not been discussed before. Meanwhile, they can transform multiple in-phase sources into one. Other intriguing illusion effects are also demonstrated. Based on the Riemann sheet analysis, the physics mechanism of such effects are well explained. Finally, we apply transmutation methods to design lenses without any singular material parameters.

  18. Science at the Speed of Light: Advanced Photon Source

    ScienceCinema

    Murray Gibson

    2016-07-12

    An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest x-ray beams in the Western Hemisphere, and the research carried out by scientists using those x-rays.

  19. Science at the Speed of Light: Advanced Photon Source

    SciTech Connect

    Murray Gibson

    2009-06-03

    An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest x-ray beams in the Western Hemisphere, and the research carried out by scientists using those x-rays.

  20. Modelling of a laser-pumped light source for endoscopic surgery

    NASA Astrophysics Data System (ADS)

    Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.

    2008-09-01

    A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.

  1. White LED compared with other light sources: age-dependent photobiological effects and parameters for evaluation.

    PubMed

    Rebec, Katja Malovrh; Klanjšek-Gunde, Marta; Bizjak, Grega; Kobav, Matej B

    2015-01-01

    Ergonomic science at work and living places should appraise human factors concerning the photobiological effects of lighting. Thorough knowledge on this subject has been gained in the past; however, few attempts have been made to propose suitable evaluation parameters. The blue light hazard and its influence on melatonin secretion in age-dependent observers is considered in this paper and parameters for its evaluation are proposed. New parameters were applied to analyse the effects of white light-emitting diode (LED) light sources and to compare them with the currently applied light sources. The photobiological effects of light sources with the same illuminance but different spectral power distribution were determined for healthy 4-76-year-old observers. The suitability of new parameters is discussed. Correlated colour temperature, the only parameter currently used to assess photobiological effects, is evaluated and compared to new parameters. PMID:26647954

  2. In situ calibration of a light source in a sensor device

    DOEpatents

    Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.

    2015-12-29

    A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

  3. A novel photobioreactor structure using optical fibers as inner light source to fulfill flashing light effects of microalgae.

    PubMed

    Xue, Shengzhang; Zhang, Qinghua; Wu, Xia; Yan, Chenghu; Cong, Wei

    2013-06-01

    In this work, a novel photobioreactor structure using optical fibers being fixed vertically to culture flow direction as inner light source was proposed to fulfill flashing light effects (FLE) of microalgae, so as to obtain high light efficiency. Three types of optical-fiber photobioreactor fulfilling FLE of microalgae, i.e. air-driven panel, pump-driven panel and stirred tank type, were proposed and a 130 L airlift panel one was practically constructed on which both cold (light profile, liquid velocity) and hot model tests were carried out. Results demonstrated that it could produce uniformed light/dark frequencies being over 10 Hz and microalgae productivity increased by 43% and 38% for Spirulina platensis and Scenedesmus dimorphus respectively, compared with the control. This suggested the structure to be a viable and promising option for future photobioreactors. PMID:23612173

  4. Influence of Lithium Additives in Small Molecule Light-Emitting Electrochemical Cells.

    PubMed

    Lin, Kuo-Yao; Bastatas, Lyndon D; Suhr, Kristin J; Moore, Matthew D; Holliday, Bradley J; Minary-Jolandan, Majid; Slinker, Jason D

    2016-07-01

    Light-emitting electrochemical cells (LEECs) utilizing small molecule emitters such as iridium complexes have great potential as low-cost emissive devices. In these devices, ions rearrange during operation to facilitate carrier injection, bringing about efficient operation from simple, single layer devices. Recent work has shown that the luminance, efficiency, and responsiveness of iridium-based LEECs are greatly enhanced by the inclusion of small amounts of lithium salts (≤0.5%/wt) into the active layer. However, the origin of this enhancement has yet to be demonstrated experimentally. Furthermore, although iridium-based devices have been the longstanding leader among small molecule LEECs, fundamental understanding of the ionic distribution in these devices under operation is lacking. Herein, we use scanning Kelvin probe microscopy to measure the in situ potential profiles and electric field distributions of planar iridium-based LEECs and clarify the role of ionic lithium additives. In pristine devices, it is found that ions do not pack densely at the cathode, and ionic redistribution is slow. Inclusion of small amounts of Li[PF6] greatly increases ionic space charge near the cathode that doubles the peak electric fields and enhances electronic injection relative to pristine devices. This study confirms and clarifies a number of longstanding hypotheses regarding iridium LEECs and recent postulates concerning optimization of their operation. PMID:27299981

  5. Influence of Lithium Additives in Small Molecule Light-Emitting Electrochemical Cells.

    PubMed

    Lin, Kuo-Yao; Bastatas, Lyndon D; Suhr, Kristin J; Moore, Matthew D; Holliday, Bradley J; Minary-Jolandan, Majid; Slinker, Jason D

    2016-07-01

    Light-emitting electrochemical cells (LEECs) utilizing small molecule emitters such as iridium complexes have great potential as low-cost emissive devices. In these devices, ions rearrange during operation to facilitate carrier injection, bringing about efficient operation from simple, single layer devices. Recent work has shown that the luminance, efficiency, and responsiveness of iridium-based LEECs are greatly enhanced by the inclusion of small amounts of lithium salts (≤0.5%/wt) into the active layer. However, the origin of this enhancement has yet to be demonstrated experimentally. Furthermore, although iridium-based devices have been the longstanding leader among small molecule LEECs, fundamental understanding of the ionic distribution in these devices under operation is lacking. Herein, we use scanning Kelvin probe microscopy to measure the in situ potential profiles and electric field distributions of planar iridium-based LEECs and clarify the role of ionic lithium additives. In pristine devices, it is found that ions do not pack densely at the cathode, and ionic redistribution is slow. Inclusion of small amounts of Li[PF6] greatly increases ionic space charge near the cathode that doubles the peak electric fields and enhances electronic injection relative to pristine devices. This study confirms and clarifies a number of longstanding hypotheses regarding iridium LEECs and recent postulates concerning optimization of their operation.

  6. Study of Selecting on Light Source Used for Micro-algae Cultivation in Space

    NASA Astrophysics Data System (ADS)

    Ai, Weidang; Ai, Weidang; Guo, Shuang-Sheng; Gao, Feng; Tang, Yong-Kang; Qin, Li-Feng

    To select suitable light source for micro-algae cultivation in future space station, the selected Spirulina plastensis(No.7) were cultured under different lightening qualities, including six light sources that were made up of different combinations of red and blue light-emitting diode(LED). The growth, photosynthetic efficiency and nutrition quality of the Spirulina, were analyzed. From the experiments, the red light may promote the cumulation of biomass of the Spirulina, and the cumulating rate was the highest under all red light source, but the syntheses of protein, phycobiliprotein, β-carotene, VE and other nutrients needs a certain portion of blue light; yet, the complete blue light condition is not favorable to the growth of Spirulina, and may bring pollution by chlorella and other kinds of micro-algae. It is concluded that the LEDs can be used as the light resource of micro-algae cultivation. The normal growth and development of microalgae need two light sources of both red and blue LEDs. The comprehensive analyses of the various factors that affect the growth of Spirulina, such as nutrition quality and photosynthetic activities, etc., showed that the combination of 80% red and 20% blue LED is the optimum one among those tested combinations. Key word: light-emitting diode; micro-algae; controlled ecological life support system (CELSS); space cultivation

  7. Spectral purification and infrared light recycling in extreme ultraviolet lithography sources.

    PubMed

    Bayraktar, Muharrem; van Goor, Fred A; Boller, Klaus J; Bijkerk, Fred

    2014-04-01

    We present the design of a novel collector mirror for laser produced plasma (LPP) light sources to be used in extreme ultraviolet (EUV) lithography. The design prevents undesired infrared (IR) drive laser light, reflected from the plasma, from reaching the exit of the light source. This results in a strong purification of the EUV light, while the reflected IR light becomes refocused into the plasma for enhancing the IR-to-EUV conversion. The dual advantage of EUV purification and conversion enhancement is achieved by incorporating an IR Fresnel zone plate pattern into the EUV reflective multilayer coating of the collector mirror. Calculations using Fresnel-Kirchhoff's diffraction theory for a typical collector design show that the IR light at the EUV exit is suppressed by four orders of magnitude. Simultaneously, 37% of the reflected IR light is refocused back the plasma. PMID:24718234

  8. Design of an inexpensive integrating sphere student laboratory setup for the optical characterization of light sources

    NASA Astrophysics Data System (ADS)

    Leloup, Frédéric B.; Leyre, Sven; Bauwens, Eva; Van den Abeele, Toon; Hanselaer, Peter

    2016-01-01

    In this paper, the design of an inexpensive integrating sphere setup is presented, enabling students to perform optical characterization of light sources with reasonable accuracy, in a student laboratory context. Instead of using an expensive sphere with magnesium oxide or barium sulfate coating, a cheap polystyrene sphere is employed. In combination with a low-cost USB spectroradiometer, the system enables the direct measurement of the spectral radiant power of a light source. In addition to the radiant power, the luminous flux, luminous efficacy, and distinctive colorimetric quantities (colour coordinates, colour temperature, and colour rendering index) can be determined. Besides a description of the equipment used, the experimental measurement procedure and some typical measurement results are presented. A comparison between the data and the results obtained with scientific metrology instrumentation indicates reasonable accuracy. As a result, it can be concluded that the purpose of the presented experiments, being that students become acquainted with applications of radiometry and photometry, and with data collection and data analysis as in a professional context, is fully achieved with the described test setup.

  9. Optical-Fiber Fluorosensors With Polarized Light Sources

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  10. HUBBLE IDENTIFIES SOURCE OF ULTRAVIOLET LIGHT IN AN OLD GALAXY

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Hubble Space Telescope's exquisite resolution has allowed astronomers to resolve, for the first time, hot blue stars deep inside an elliptical galaxy. The swarm of nearly 8,000 blue stars resembles a blizzard of snowflakes near the core (lower right) of the neighboring galaxy M32, located 2.5 million light-years away in the constellation Andromeda. Hubble confirms that the ultraviolet light comes from a population of extremely hot helium-burning stars at a late stage in their lives. Unlike the Sun, which burns hydrogen into helium, these old stars exhausted their central hydrogen long ago, and now burn helium into heavier elements. The observations, taken in October 1998, were made with the camera mode of the Space Telescope Imaging Spectrograph (STIS) in ultraviolet light. The STIS field of view is only a small portion of the entire galaxy, which is 20 times wider on the sky. For reference, the full moon is 70 times wider than the STIS field-of-view. The bright center of the galaxy was placed on the right side of the image, allowing fainter stars to be seen on the left side of the image. These results are to be published in the March 1, 2000 issue of The Astrophysical Journal. Thirty years ago, the first ultraviolet observations of elliptical galaxies showed that they were surprisingly bright when viewed in ultraviolet light. Before those pioneering UV observations, old groups of stars were assumed to be relatively cool and thus extremely faint in the ultraviolet. Over the years since the initial discovery of this unexpected ultraviolet light, indirect evidence has accumulated that it originates in a population of old, but hot, helium-burning stars. Now Hubble provides the first direct visual evidence. Nearby elliptical galaxies are thought to be relatively simple galaxies comprised of old stars. Because they are among the brightest objects in the Universe, this simplicity makes them useful for tracing the evolution of stars and galaxies. Credits: NASA and Thomas

  11. A SYNCHRONIZED FIR/VUV LIGHT SOURCE AT JEFFERSON LAB

    SciTech Connect

    Stephen Benson, David Douglas, George Neil, Michelle D. Shinn, Gwyn Williams

    2012-07-01

    We describe a dual free-electron laser (FEL) configuration on the UV Demo FEL at Jefferson Lab that allows simultaneous lasing at FIR/THz and UV wavelengths. The FIR/THz source would be an FEL oscillator with a short wiggler providing nearly diffraction-limited pulses with pulse energy exceeding 50 microJoules. The FIR source would use the exhaust beam from a UVFEL. The coherent harmonics in the VUV from the UVFEL are out-coupled through a hole. The FIR source uses a shorter resonator with either hole or edge coupling to provide very high power FIR pulses. Simulations indicate excel-lent spectral brightness in the FIR region with over 100 W/cm-1 output.

  12. High-resolution full-field spatial coherence gated optical tomography using monochromatic light source

    NASA Astrophysics Data System (ADS)

    Srivastava, Vishal; Nandy, Sreyankar; Singh Mehta, Dalip

    2013-09-01

    We demonstrate dispersion free, high-resolution full-field spatial coherence gated optical tomography using spatially incoherent monochromatic light source. Spatial coherence properties of light source were synthesized by means of combining a static diffuser and vibrating multi mode fiber bundle. Due to low spatial coherence of light source, the axial resolution of the system was achieved similar to that of conventional optical coherence tomography which utilizes low temporal coherence. Experimental results of fringe visibility versus optical path difference are presented for varying numerical apertures objective lenses. High resolution optically sectioned images of multilayer onion skin, and red blood cells are presented.

  13. Undulator based scanning microscope at the National Synchrotron Light Source

    SciTech Connect

    Rarback, H.; Shu, D.; Ade, H.; Jacobsen, C.; Kirz, J.; McNulty, I.; Rosser, R.

    1986-01-01

    A second generation scanning soft x-ray microscope is under construction, designed to utilize the dramatic increase in source bightness available at the soft x-ray undulator. The new instrument is expected to reduce image acquisition time by a factor of about 100, and to improve resolution, stability, and reproducibility.

  14. Metrological advantages of the light source based on optically connected integrating spheres

    NASA Astrophysics Data System (ADS)

    Mikheenko, Leonid; Borovytsky, Volodymyr

    2012-10-01

    The paper presents the metrological analysis of the light sources which have a form of several optically connected integrating spheres. This light sources contain several (3 ... 11) primary integrating spheres of small diameters that are installed on a secondary integrating sphere of bigger diameter. The initial light sources - halogen lamps or light emitted diodes are installed inside the primary integrating spheres. These spheres are mounted on the secondary integrating sphere. The radiation comes from the primary integrating spheres to the secondary one through the diaphragms which diameters can be varied. It makes possible to control the total flux coming through the diaphragms and to set the required output radiance. The secondary integrating sphere has an output aperture where uniform radiance emits. The paper discusses the technique for calculation of the precision of the output radiance according to variations of optical and geometrical parameters of the light source. There are investigated influences of power supply, reflectance properties, diameters of internal surfaces of the integrating spheres and diameters of diaphragms between the integrating spheres. The precision of the output radiance is better than 1.9 % for the non-expensive light sources. For the high-quality light sources it can reach 0.7 %. The possible range of the output radiance is from 0 to 1 200 W/(st•m2). These facts confirm the sufficient metrological advantages of the proposed light sources for absolute radiometric measurements. The proposed light sources can be considered as one of the best candidates for calibration of the modern remote sensing instruments and high quality imaging systems working in optical range 0.4 - 2.2 μkm.

  15. Which Light for Cultural Heritage: Comparison of Light Sources with Respect to Realgar Photodegradation

    NASA Astrophysics Data System (ADS)

    Macchia, A.; Cesaro, S. Nunziante; Campanella, L.; Maras, A.; Rocchia, M.; Roscioli, G.

    2013-11-01

    This paper is a part of the wider project aiming at determining how lighting systems can be standardized and developed, by studying the interaction between light and the constituting materials. To develop this research, an interesting case-study was performed as starting point: realgar photo-degradation. Light transforms realgar in arsenolite and pararealgar, a compound with the same formula of realgar but characterized by a different atomic disposition and color. This study deepens our knowledge of realgar degradation and determines the capacity of inducing degradation by different lamps. The survey was carried out by means of FTIR and micro-Raman spectroscopy. The results confirm literature studies on realgar degradation and suggest that the LED lamp produces less degradation, keeping a high quality of lighting.

  16. Fast space-varying convolution using matrix source coding with applications to camera stray light reduction.

    PubMed

    Wei, Jianing; Bouman, Charles A; Allebach, Jan P

    2014-05-01

    Many imaging applications require the implementation of space-varying convolution for accurate restoration and reconstruction of images. Here, we use the term space-varying convolution to refer to linear operators whose impulse response has slow spatial variation. In addition, these space-varying convolution operators are often dense, so direct implementation of the convolution operator is typically computationally impractical. One such example is the problem of stray light reduction in digital cameras, which requires the implementation of a dense space-varying deconvolution operator. However, other inverse problems, such as iterative tomographic reconstruction, can also depend on the implementation of dense space-varying convolution. While space-invariant convolution can be efficiently implemented with the fast Fourier transform, this approach does not work for space-varying operators. So direct convolution is often the only option for implementing space-varying convolution. In this paper, we develop a general approach to the efficient implementation of space-varying convolution, and demonstrate its use in the application of stray light reduction. Our approach, which we call matrix source coding, is based on lossy source coding of the dense space-varying convolution matrix. Importantly, by coding the transformation matrix, we not only reduce the memory required to store it; we also dramatically reduce the computation required to implement matrix-vector products. Our algorithm is able to reduce computation by approximately factoring the dense space-varying convolution operator into a product of sparse transforms. Experimental results show that our method can dramatically reduce the computation required for stray light reduction while maintaining high accuracy. PMID:24710398

  17. An Electron Bunch Compression Scheme for a Superconducting Radio Frequency Linear Accelerator Driven Light Source

    SciTech Connect

    C. Tennant, S.V. Benson, D. Douglas, P. Evtushenko, R.A. Legg

    2011-09-01

    We describe an electron bunch compression scheme suitable for use in a light source driven by a superconducting radio frequency (SRF) linac. The key feature is the use of a recirculating linac to perform the initial bunch compression. Phasing of the second pass beam through the linac is chosen to de-chirp the electron bunch prior to acceleration to the final energy in an SRF linac ('afterburner'). The final bunch compression is then done at maximum energy. This scheme has the potential to circumvent some of the most technically challenging aspects of current longitudinal matches; namely transporting a fully compressed, high peak current electron bunch through an extended SRF environment, the need for a RF harmonic linearizer and the need for a laser heater. Additional benefits include a substantial savings in capital and operational costs by efficiently using the available SRF gradient.

  18. Synchrotron X-Ray Microdiffraction Studies of Electromigration in Interconnect lines at the Advanced Light Source

    SciTech Connect

    Tamura, Nobumichi; Chen, Kai; Kunz, Martin

    2009-12-01

    Synchrotron polychromatic X-ray microdiffraction is a particularly suitable technique to study in situ the effect of electromigration in metal interconnects as add spatial resolution to grain orientation and strain sensitivity. This technique has been extensively used at the Advanced Light Source to monitor changes in aluminum and copper interconnect test structures while high-density current is passed into them during accelerated tests at elevated temperature. One of the principal findings is the observation of electromigration-induced plasticity in the metal lines that appear during the very early stages of electromigration. In some of the lines, high density of geometrically necessary dislocation are formed leading to additional diffusion paths causing an enhancement of electromigration effect at test temperature.

  19. Gamma-Ray Compton Light Source Development at LLNL

    NASA Astrophysics Data System (ADS)

    Hartemann, Frederic; Anderson, Scott; Gibson, David; Hagmann, Chris; Johnson, Micah; Jovanovic, Igor; Messerly, Mike; Pruet, Jason; Shverdin, Miro; Tremaine, Aaron; McNabb, Dennis; Siders, Craig; Barty, Chris

    2007-03-01

    A new class of tunable, monochromatic gamma-ray sources capable of operating at high peak and average brightness is currently being developed at LLNL for nuclear photo-science and applications. These novel systems are based on Compton scattering of laser photons by a high brightness relativistic electron beam produced by an rf photoinjector. Key technologies, basic scaling laws, and recent experimental results will be presented, along with an overview of future research and development directions.

  20. Laser produced plasma for efficient extreme ultraviolet light sources

    SciTech Connect

    Donnelly, Tony; Cummins, Thomas; O' Gorman, Colm; Li Bowen; Harte, Colm S.; O'Reilly, Fergal; Sokell, Emma; Dunne, Padraig; O'Sullivan, Gerry

    2012-05-25

    Extreme ultraviolet emission from laser produced plasma and their relevance to EUV source development is discussed. The current state of the field for Sn LPP sources operating at 13.5 nm is described and initial results are given for EUV emission from CO{sub 2} laser irradiation of a bulk Sn target. A maximum conversion efficiency of 1.7% has been measured and the influence of the CO{sub 2} laser temporal profile on the CE is discussed. A double pulse irradiation scheme is shown to increase CE up to a maximum value of 2.1% for an optimum prepulse - pulse delay of 150 ns. The emergence of a new EUVL source wavelength at 6.7 nm based on Gd and Tb LPPs has been outlined. An initial experiment investigating picosecond laser irradiation as a means to produce strong 6.7 nm emission from a Gd{sub 2}O{sub 3} target has been performed and verified.

  1. LLNL's Precision Compton Scattering Light Source: Status & Applications

    NASA Astrophysics Data System (ADS)

    Hartemann, F. V.; Albert, F.; Anderson, S. G.; Bayramian, A. J.; Cross, R. R.; Ebbers, C. A.; Gibson, D. J.; Houck, T. L.; Marsh, R. A.; Messerly, M. J.; Shverdin, M. Y.; Wu, S. S.; Scarpetti, R. D.; Siders, C. W.; McNabb, D. P.; Bonanno, R. E.; Barty, C. P. J.; Adolphsen, C. E.; Chu, T. S.; Jongewaard, E. N.; Li, Z.; Tantawi, S. G.; Vlieks, A. E.; Wang, J. W.; Raubenheimer, T. O.

    2010-11-01

    A precision, tunable, monochromatic (< 0.4% rms spectral width) source driven by a compact, high-gradient X-band linac designed in collaboration with SLAC is under construction at LLNL. High-brightness (250 pC, 3.5 ps, 0.4 mm.mrad), relativistic electron bunches will interact with a Joule-class, 10 ps, diode-pumped laser pulse to generate tunable >=-rays in the 0.5-2.5 MeV photon energy range. This >=-ray source will be used to excite nuclear resonance fluorescence (NRF) in various isotopes, of interest for homeland security, stockpile science and surveillance, nuclear fuel assay, and waste imaging and assay. The source current status will be discussed, along with important applications, including NRF and in situ ps thermal measurements. This work performed under the auspices of the U.S. DoE by LLNL under Contract DE-AC52-07NA27344, and funded by the DHS DNDO.

  2. Biomass and pigments production in photosynthetic bacteria wastewater treatment: effects of light sources.

    PubMed

    Zhou, Qin; Zhang, Panyue; Zhang, Guangming

    2015-03-01

    This study is aimed at enhancing biomass and pigments production together with pollution removal in photosynthetic bacteria (PSB) wastewater treatment via different light sources. Red, yellow, blue, white LED and incandescent lamp were used. Results showed different light sources had great effects on the PSB. PSB had the highest biomass production, COD removal and biomass yield with red LED. The corresponding biomass, COD removal and biomass yield reached 2580 mg/L, 88.6% and 0.49 mg-biomass/mg-COD-removal, respectively. The hydraulic retention time of wastewater treatment could be shortened to 72 h with red LED. Mechanism analysis showed higher ATP was produced with red LED than others. Light sources could significantly affect the pigments production. The pigments productions were greatly higher with LED than incandescent lamp. Yellow LED had the highest pigments production while red LED produced the highest carotenoid/bacteriochlorophyll ratio. Considering both efficiency and energy cost, red LED was the optimal light source.

  3. The light curve of a transient X-ray source. [the aeriel satellites

    NASA Technical Reports Server (NTRS)

    Kaluzienski, L. J.; Holt, S. S.; Boldt, E. A.; Serlemitsos, P. J.; Eadie, G.; Pounds, K. A.; Ricketts, M. J.; Watson, M.

    1975-01-01

    The Ariel-V satellite monitored the X-ray light curve of A1524-62 almost continuously from 40 days prior to maximum light until its disappearance below the effective experimental sensitivity. The source exhibited maximum light on approximately 4 December 1974, at a level of 0.9 the apparent magnitude of the Crab Nebula in the energy band 3-6 keV. Although similar to previously reported transient sources with a decay time constant of approximately 2 months, the source exhibited an extended, variable pre-flare on-state of about 1 month at a level of greater than approximately 0.1 maximum light. The four bright (greater than 0.2 of the Crab Nebula) transient sources observed during the first half-year of Ariel-V operation are indicative of a galactic disk distribution, and a luminosity at maximum in excess of 10 to the 37th power ergs/sec.

  4. National synchrotron light source. [Annual report], October 1, 1992--September 30, 1993

    SciTech Connect

    Rothman, E.Z.; Hulbert, S.L.; Lazarz, N.M.

    1994-04-01

    This report contains brief discussions on the research being conducted at the National Synchrotron Light source. Some of the topics covered are: X-ray spectroscopy; nuclear physics; atomic and molecular science; meetings and workshops; operations; and facility improvements.

  5. Pulsed-laser micropatterned quantum-dot array for white light source

    NASA Astrophysics Data System (ADS)

    Wang, Sheng-Wen; Lin, Huang-Yu; Lin, Chien-Chung; Kao, Tsung Sheng; Chen, Kuo-Ju; Han, Hau-Vei; Li, Jie-Ru; Lee, Po-Tsung; Chen, Huang-Ming; Hong, Ming-Hui; Kuo, Hao-Chung

    2016-03-01

    In this study, a novel photoluminescent quantum dots device with laser-processed microscale patterns has been demonstrated to be used as a white light emitting source. The pulsed laser ablation technique was employed to directly fabricate microscale square holes with nano-ripple structures onto the sapphire substrate of a flip-chip blue light-emitting diode, confining sprayed quantum dots into well-defined areas and eliminating the coffee ring effect. The electroluminescence characterizations showed that the white light emission from the developed photoluminescent quantum-dot light-emitting diode exhibits stable emission at different driving currents. With a flexibility of controlling the quantum dots proportions in the patterned square holes, our developed white-light emitting source not only can be employed in the display applications with color triangle enlarged by 47% compared with the NTSC standard, but also provide the great potential in future lighting industry with the correlated color temperature continuously changed in a wide range.

  6. Science and Technology of Future Light Sources: A White Paper

    SciTech Connect

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, a= Janos; Long, Gabrielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z.-X.; Shenoy, Gopal; Schoenlein, Bob; Shen, Qun; /Argonne /Brookhaven /LBL, Berkeley /SLAC, SSRL

    2009-02-03

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects (Figure 1.1). The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter

  7. Accident source terms for Light-Water Nuclear Power Plants. Final report

    SciTech Connect

    Soffer, L.; Burson, S.B.; Ferrell, C.M.; Lee, R.Y.; Ridgely, J.N.

    1995-02-01

    In 1962 tile US Atomic Energy Commission published TID-14844, ``Calculation of Distance Factors for Power and Test Reactors`` which specified a release of fission products from the core to the reactor containment for a postulated accident involving ``substantial meltdown of the core``. This ``source term``, tile basis for tile NRC`s Regulatory Guides 1.3 and 1.4, has been used to determine compliance with tile NRC`s reactor site criteria, 10 CFR Part 100, and to evaluate other important plant performance requirements. During the past 30 years substantial additional information on fission product releases has been developed based on significant severe accident research. This document utilizes this research by providing more realistic estimates of the ``source term`` release into containment, in terms of timing, nuclide types, quantities and chemical form, given a severe core-melt accident. This revised ``source term`` is to be applied to the design of future light water reactors (LWRs). Current LWR licensees may voluntarily propose applications based upon it.

  8. Advanced Light Source report. Volume 7, No. 1

    SciTech Connect

    Not Available

    1994-09-01

    The exceptional science already emerging from the user program at the ALS shows that the promises of ``unique research opportunities`` and ``experiments not possible anywhere else`` made at the inception of the ALS are indeed coming true. In less than a year of beamline operations, the ALS has produced numerous high-quality results and achieved an enviable level of performance. Since the beginning of 1994, the ALS has operated for 92% of its scheduled hours, an outstanding achievement for a new machine. The ALS` ability to deliver the brightest light in the world in the ultraviolet and soft x-ray regions of the spectrum has attracted a who`s who of synchrotron research to the experiment floor. These users have produced a variety of scientifically significant results during the ALS` first year of operation, a few of which are highlighted in this article.

  9. Imaging spectroscopic analysis at the Advanced Light Source

    SciTech Connect

    MacDowell, A. A.; Warwick, T.; Anders, S.; Lamble, G.M.; Martin, M.C.; McKinney, W.R.; Padmore, H.A.

    1999-05-12

    One of the major advances at the high brightness third generation synchrotrons is the dramatic improvement of imaging capability. There is a large multi-disciplinary effort underway at the ALS to develop imaging X-ray, UV and Infra-red spectroscopic analysis on a spatial scale from. a few microns to 10nm. These developments make use of light that varies in energy from 6meV to 15KeV. Imaging and spectroscopy are finding applications in surface science, bulk materials analysis, semiconductor structures, particulate contaminants, magnetic thin films, biology and environmental science. This article is an overview and status report from the developers of some of these techniques at the ALS. The following table lists all the currently available microscopes at the. ALS. This article will describe some of the microscopes and some of the early applications.

  10. Evidence for an Additional Heat Source in the Warm Ionized Medium of Galaxies.

    PubMed

    Reynolds; Haffner; Tufte

    1999-11-01

    Spatial variations of the [S ii]/Halpha and [N ii]/Halpha line intensity ratios observed in the gaseous halo of the Milky Way and other galaxies are inconsistent with pure photoionization models. They appear to require a supplemental heating mechanism that increases the electron temperature at low densities, ne. This would imply that in addition to photoionization, which has a heating rate per unit volume proportional to n2e, there is another source of heat with a rate per unit volume proportional to a lower power of ne. One possible mechanism is the dissipation of interstellar plasma turbulence, which, according to Minter & Spangler, heats the ionized interstellar medium in the Milky Way at a rate of approximately 1x10-25ne ergs cm-3 s-1. If such a source were present, it would dominate over photoionization heating in regions where ne less, similar0.1 cm-3, producing the observed increases in the [S ii]/Halpha and [N ii]/Halpha intensity ratios at large distances from the galactic midplane as well as accounting for the constancy of [S ii]/[N ii], which is not explained by pure photoionization. Other supplemental heating sources, such as magnetic reconnection, cosmic rays, or photoelectric emission from small grains, could also account for these observations, provided they supply approximately 10-5 ergs s-1 per square centimeter of the Galactic disk to the warm ionized medium.

  11. Composite-type Rb-87 optical-pumping light source for the rubidium frequency standard

    NASA Technical Reports Server (NTRS)

    Oura, N.; Kuramochi, N.; Naritsuka, S.; Hayashi, T.

    1982-01-01

    The light source is composed of a cylindrical Rb-87 lamp 10 mm diameter and a Rb-85 filter cell 3-7 mm long attached to the front flat face of the lamp. This composite type device is operated in an oven at about 100 C. Thus a light source for Rb-87 hyperfine optical pumping less than 4 cm long by 3 cm diameter was constructed.

  12. A dual-beam actinic light source for photosynthesis research

    NASA Technical Reports Server (NTRS)

    Margozzi, A. P.; Henderson, M. E.

    1972-01-01

    Simulation of photosynthetic process in plants is accomplished by using two separate and identical optical channels that provide independently adjustable wavelengths (filters), shutter sequencing, and control intensity of illumination. In addition to experiments using electron paramagnetic resonance spectroscopy, system may be applicable to other types of research in photosynthetic field.

  13. Hybrid white light sources based on layer-by-layer assembly of nanocrystals on near-UV emitting diodes

    NASA Astrophysics Data System (ADS)

    Nizamoglu, Sedat; Demir, Hilmi Volkan

    2007-10-01

    We present the design, growth, fabrication, integration and characterization of alternative hybrid white light sources based on the controlled layer-by-layer assembly of nanocrystals on UV-emitting nitride diodes for adjustable white light parameters. We hybridize CdSe/ZnS core-shell nanocrystals of different sizes (1.9-3.2-5.2 nm) on InGaN/GaN LEDs as a near-UV excitation source at 383 nm for efficient pumping. The first device includes layer-by-layer assembly of dichromatic cyan- and red-emitting nanocrystals (λPL = 504-615 nm) leading to the tristimulus coordinates (x = 0.37,y = 0.46); the second device uses the trichromatic combination of layer-by-layer hybridized cyan-, yellow- and red-emitting nanocrystals (λPL = 504-580-615 nm), yielding (x = 0.38,y = 0.48). Such layer-by-layer hybridization offers the advantages of precisely controlling individual nanocrystal film thicknesses and order in addition to concentrations. By utilizing such multiple combinations of nanocrystals in the assembly, the light parameters are well controlled and adjusted. Leveraging rapidly advancing UV technology into efficient lighting with nanocrystal based color conversion, it is critical to develop and demonstrate hybrid light sources on UV pumping platforms.

  14. Volume-scalable high-brightness three-dimensional visible light source

    SciTech Connect

    Subramania, Ganapathi; Fischer, Arthur J; Wang, George T; Li, Qiming

    2014-02-18

    A volume-scalable, high-brightness, electrically driven visible light source comprises a three-dimensional photonic crystal (3DPC) comprising one or more direct bandgap semiconductors. The improved light emission performance of the invention is achieved based on the enhancement of radiative emission of light emitters placed inside a 3DPC due to the strong modification of the photonic density-of-states engendered by the 3DPC.

  15. Development of tunable Fabry-Perot spectral camera and light source for medical applications

    NASA Astrophysics Data System (ADS)

    Kaarre, M.; Kivi, S.; Panouillot, P. E.; Saari, H.; Mäkynen, J.; Sorri, I.; Juuti, M.

    2013-05-01

    VTT has developed a fast, tunable Fabry-Perot (FP) filter component and applied it in making small, lightweight spectral cameras and light sources. One application field where this novel technology is now tested is medical field. A demonstrator has been made to test the applicability of FP based spectral filtering in the imaging of retina in visible light wavelength area.

  16. Solution of multi-element LED light sources development automation problem

    NASA Astrophysics Data System (ADS)

    Chertov, Aleksandr N.; Gorbunova, Elena V.; Korotaev, Valery V.; Peretyagin, Vladimir S.

    2014-09-01

    The intensive development of LED technologies resulted in the creation of multicomponent light sources in the form of controlled illumination devices based on usage of mentioned LED technologies. These light sources are used in different areas of production (for example, in the food industry for sorting products or in the textile industry for quality control, etc.). The use of LED lighting products in the devices used in specialized lighting, became possible due to wide range of colors of light, LED structures (which determines the direction of radiation, the spatial distribution and intensity of the radiation, electrical, heat, power and other characteristics), and of course, the possibility of obtaining any shade in a wide dynamic range of brightness values. LED-based lighting devices are notable for the diversity of parameters and characteristics, such as color radiation, location and number of emitters, etc. Although LED technologies have several advantages, however, they require more attention if you need to ensure a certain character of illumination distribution and/or distribution of the color picture at a predetermined distance (for example, at flat surface, work zone, area of analysis or observation). This paper presents software designed for the development of the multicomponent LED light sources. The possibility of obtaining the desired color and energy distribution at the zone of analysis by specifying the spatial parameters of the created multicomponent light source and using of real power, spectral and color parameters and characteristics of the LEDs is shown as well.

  17. History of Science and Conceptual Change: The Formation of Shadows by Extended Light Sources

    ERIC Educational Resources Information Center

    Dedes, Christos; Ravanis, Konstantinos

    2009-01-01

    This study investigates the effectiveness of a teaching conflict procedure whose purpose was the transformation of the representations of 12-16-year-old pupils in Greece concerning light emission and shadow formation by extended light sources. The changes observed during the children's effort to destabilize and reorganise their representations…

  18. How to determine an appropriate dose when using various light sources in photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Moseley, Harry

    1996-12-01

    Photodynamic therapy (PDT) using 5-aminolaevulinic acid (5- ALA) has emerged as a very effective treatment for superficial skin lesions. PDT has been traditionally performed using a laser. However, the availability of broad- band non-laser sources is challenging the role of the laser. Unfortunately, dosimetry of broad-band sources presents some practical difficulties. The effectiveness of a light source for PDT depends on the incident spectral irradiance of the light, tissue transmission to the desired depth, and sensitizer absorption which depends on the particular absorbing chromophore. These elements are combined mathematically to produce the 'total effective fluence rate' at a specified depth. On applying the model to several light sources, it would appear that green light is much more effective than red light for treating down to a depth of 2.0 m in dermis but red light appears to give better superficial skin sparing. The model may be easily applied to any light source provided the incident spectral irradiance is known. It is believed that this concept has considerable practical value.

  19. Performance of light sources and radiation sensors under low gravity realized by parabolic airplane flights

    NASA Astrophysics Data System (ADS)

    Hirai, Hiroaki; Kitaya, Yoshiaki; Hirai, Takehiro

    A fundamental study was conducted to establish an experimental system for space farming. Since to ensure optimal light for plant cultivation in space is of grave importance, this study examined the performance of light sources and radiation sensors under microgravity conditions created during the parabolic airplane flight. Three kinds of light sources, a halogen bulb, a fluorescent tube, and blue and red LEDs, and ten models of radiation sensors available in the market were used for the experiment. Surface temperature of the light sources, output signals from the radiation sensors, spectroscopic characteristics were measured at the gravity levels of 0.01, 1.0 and 1.8 G for 20 seconds each during parabolic airplane flights. As a result, the performance of the halogen lamp was affected the most by the gravity level among the three light sources. Under the microgravity conditions which do not raise heat convection, the temperature of the halogen lamp rose and the output of the radiation sensors increased. Spectral distributions of the halogen lamp indicated that peak wavelength appeared the highest at the level of 0.01G, which contributed to the increase in light intensity. In the case of red and blue LEDs, which are promising light sources in space farming, the temperature of both LED chips rose but irradiance from red LED increased and that from blue LED decreased under microgravity conditions due to the different thermal characteristics.

  20. Laser-driven phosphor-converted white light source for solid-state illumination.

    PubMed

    George, Anthony F; Al-waisawy, Sara; Wright, Jason T; Jadwisienczak, Wojciech M; Rahman, Faiz

    2016-03-10

    Energy efficiency and lighting quality considerations are driving research into laser-pumped white light sources. Laser diodes as pump sources for downconversion phosphors promise freedom from "droop" that adversely affects the efficiency of light-emitting diodes (LEDs). High-intensity laser diode-pumped light sources for applications such as search lights and automobile headlights have been demonstrated recently. Our paper describes the design and construction of a domestic/office-type solid-state luminaire driven by light from an integrated violet laser-diode module. A trichromatic phosphor made from a blend of separate europium-containing rare-earth phosphors was used as the downconversion medium. Mechanical and optical design of the reflector and the phosphor plate are described. Characteristics of both the pump light and the downconverted light are also described. Our studies also looked at the variation of chromaticity coordinates with variation in pump power and the effect of laser speckle on the lamp's light output. Finally, there is a brief discussion of energy conversion efficiency and longevity considerations, comparing pumping with LEDs versus pumping with laser diodes. PMID:26974780

  1. Accelerated Source-Encoding Full-Waveform Inversion with Additional Constraints

    NASA Astrophysics Data System (ADS)

    Boehm, C.; Fichtner, A.; Ulbrich, M.

    2014-12-01

    We present a flexible framework of Newton-type methods for constrained full-waveform inversion in the time domain. Our main goal is (1) to incorporate additional prior knowledge by using general constraints on the model parameters and (2) to reduce the computational costs of solving the inverse problem by tailoring source-encoding strategies to Newton-type methods.In particular, we apply the Moreau-Yosida regularization to handle the constraints and use a continuation strategy to adjust the regularization parameter. Furthermore, we propose a semismooth Newton method with a trust-region globalization that relies on second-order adjoints to compute the Newton system with a matrix-free preconditioned conjugate gradient solver. The costs of conventional FWI approaches scale proportionally with the number of seismic sources. Here, source-encoding strategies that trigger different sources simultaneously have been proven to be a successful tool to trade a small loss of information for huge savings of computational time to solve the inverse problem. This is particularly interesting for our setting as one iteration of Newton's methods using the full Hessian is considerably more expensive than quasi-Newton methods like L-BFGS. To this end, we discuss a sample average approximation model that is accelerated by using inexact Hessian information based on mini-batches of the samples. Furthermore, we compare its performance with stochastic descent schemes. Here, the classical stochastic gradient method is accelerated by an L-BFGS preconditioner and moreover, the stability of this stochastic preconditioner is enhanced by using the Hessian instead of only gradient information.Numerical results are presented for problems in geophysical exploration on reservoir-scale.

  2. A beamline for macromolecular crystallography at the Advanced Light Source

    SciTech Connect

    Padmore, H.A.; Earnest, T.; Kim, S.H.; Thompson, A.C.; Robinson, A.L.

    1994-08-01

    A beamline for macromolecular crystallography has been designed for the ALS. The source will be a 37-pole wiggler with a, 2-T on-axis peak field. The wiggler will illuminate three beamlines, each accepting 3 mrad of horizontal aperture. The central beamline will primarily be used for multiple-wavelength anomalous dispersion measurements in the wavelength range from 4 to 0.9 {angstrom}. The beamline optics will comprise a double-crystal monochromator with a collimating pre-mirror and a double-focusing mirror after the monochromator. The two side stations will be used for fixed-wavelength experiments within the wavelength range from 1.5 to 0.95 {angstrom}. The optics will consist of a conventional vertically focusing cylindrical mirror followed by an asymmetrically cut curved-crystal monochromator. This paper presents details of the optimization of the wiggler source for crystallography, gives a description of the beamline configuration, and discusses the reasons for the choices made.

  3. Where we are in light source performance; Where we sould like to get

    SciTech Connect

    Waymouth, J.F.

    1996-05-01

    The 117-year history of the electric lighting industry has witnessed dramatic increases in light source performance, from 2-3 lumens of light per electrical watt of power input for Edison`s carbon-filament incandescent lamp to 100+ lumens per watt for electric discharge sources today. Performance improvement has been in the main episodic rather than continuous, marked by factor-two (or more) increases over prior devices upon introduction of totally new light sources. Unfortunately, no such dramatically-new light sources have been discovered in the last quarter-century. This raises the question whether the industry has reached a thermodynamic limit. In this presentation, the author discusses the twin components of light source efficacy; efficiency of conversion of electric power to radiant power, and the optimization of spectral power distribution of that radiant power to produce the maximum luminous flux consistent with {open_quotes}white light{close_quotes}. That is, light including sufficiently diverse wavelengths to illuminate satisfactorily objects of any color, while sufficiently concentrated in regions of maximum eye sensitivity to produce maximum luminous flux. Maximum efficiency of conversion of electric power to radiant power presently obtained is about 70%. Maximum luminous efficacy of the optimum visible spectrum is about 300 lumens per radiant watt. If these existed in the same product, it would have an efficacy of 200 lumens per electrical watt, about double the best presently obtained. Thus it would appear that no thermodynamic limit has been reached and at least one more doubling of light source efficacy is possible if someone is clever enough to discover it. A consortium funded by lamp manufacturers and the Electric Power Research Institute is being established to support extramural research seeking such a discovery. Independent participation and funding may also be available from Government funding agencies.

  4. High Power Light Gas Helicon Plasma Source For VASMIR

    NASA Technical Reports Server (NTRS)

    Squire, J. P.; Chang-Diaz, F. R.; Glover, T. W.; Jacobson, V. T.; McCaskill, G. E.; Winter, D. S.; Baity, F. W.; Carter, M. D.; Goulding, R. H.

    2004-01-01

    The VASIMR space propulsion development effort relies on a high power (greater than 10kW) helicon source to produce a dense flowing plasma (H, D and He) target for ion cyclotron resonance (ICR) acceleration of the ions. Subsequent expansion in an expanding magnetic field (magnetic nozzle) converts ion lunetic energy to directed momentum. This plasma source must have critical features to enable an effective propulsion device. First, it must ionize most of the input neutral flux of gas, thus producing a plasma stream with a high degree of ionization for application of ICR power. This avoids propellant waste and potential power losses due to charge exchange. Next, the plasma stream must flow into a region of high magnetic field (approximately 0.5 T) for efficient ICR acceleration. Third, the ratio of input power to plasma flux must be low, providing an energy per ion-electron pair approaching 100 eV. Lastly, the source must be robust and capable of very long life-times (years). In our helicon experiment (VX-10) we have measured a ratio of input gas to plasma flux near 100%. The plasma flows from the helicon region (B approximately 0.1 T) into a region with a peak magnetic field of 0.8 T. The energy input per ion-electron pair has been measured at 300 plus or minus 100 eV. Recent results at Oak Ridge National Laboratory (ORNL) show an enhanced efficiency mode of operation with a high power density, over 5 kW in a 5 cm diameter tube. Our helicon is presently 9 cm in diameter and operates up to 3.5 kW of input power. An upgrade to a power level of 10 kW is underway. Much of our recent work has been with a Boswell double-saddle antenna design. We are also converting the antenna design to a helical type. With these modifications, we anticipate an improvement in the ionization efficiency. This paper presents the results from scaling the helicon in the VX-10 device from 3.5 to 10 kW. We also compare the operation with a double-saddle to a helical antenna design. Finally, we

  5. Parametric Modeling of Electron Beam Loss in Synchrotron Light Sources

    SciTech Connect

    Sayyar-Rodsari, B.; Schweiger, C.; Hartman, E.; Corbett, J.; Lee, M.; Lui, P.; Paterson, E.; /SLAC

    2007-11-28

    Synchrotron light is used for a wide variety of scientific disciplines ranging from physical chemistry to molecular biology and industrial applications. As the electron beam circulates, random single-particle collisional processes lead to decay of the beam current in time. We report a simulation study in which a combined neural network (NN) and first-principles (FP) model is used to capture the decay in beam current due to Touschek, Bremsstrahlung, and Coulomb effects. The FP block in the combined model is a parametric description of the beam current decay where model parameters vary as a function of beam operating conditions (e.g. vertical scraper position, RF voltage, number of the bunches, and total beam current). The NN block provides the parameters of the FP model and is trained (through constrained nonlinear optimization) to capture the variation in model parameters as operating condition of the beam changes. Simulation results will be presented to demonstrate that the proposed combined framework accurately models beam decay as well as variation to model parameters without direct access to parameter values in the model.

  6. Seasonal variations in light scattering in the New York region and their relation to sources

    NASA Astrophysics Data System (ADS)

    Leaderer, Brain P.; Tanner, Roger L.; Lioy, Paul J.; Stolwijk, Jan A. J.

    Light scattering data collected during two periods of intensive sampling in New York City (one during summer months and one during winter months) are discussed and analyzed for diurnal patterns, their relationship to pollutant emission sources, meteorological parameters, and the size distribution and chemical composition of the ambient aerosol. The lack of a diurnal pattern for light scattering in summer in combination with a strong positive association with ozone and wind direction dependency suggests that in summer the transport of an aged aerosol in photochemically rich air masses rather than local emissions of primary pollutants is largely responsible for the observed levels of light scattering in New York City. Winter levels of light scattering observed in New York City, while approx. 50% lower than summer levels, were much less dependant on wind direction and closely related to pollutant emissions from local sources. This suggests that locally generated aerosol dominates light scattering in the winter. Particles 0.1-1.3 μm in diameter were strongly correlated with light scattering in New York City during both summer and winter periods. However, a given volume of aerosol between 0.1 and 1.3 μm scattered more light in summer than in winter, indicating the fresher nature of the winter aerosol. Variance in dry particulate light scattering was found to principally account for light extinction variance (calculated from airport visibility observations) in summer and winter. Sulfate aerosol was strongly correlated with light scattering during both summer and winter periods.

  7. Long lifetime, low intensity light source for use in nighttime viewing of equipment maps and other writings

    DOEpatents

    Frank, Alan M.; Edwards, William R.

    1983-01-01

    A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.

  8. Contributions of artificial lighting sources on light pollution in Hong Kong measured through a night sky brightness monitoring network

    NASA Astrophysics Data System (ADS)

    Pun, Chun Shing Jason; So, Chu Wing; Leung, Wai Yan; Wong, Chung Fai

    2014-05-01

    Light pollution is a form of environmental degradation in which excessive artificial outdoor lighting, such as street lamps, neon signs, and illuminated signboards, affects the natural environment and the ecosystem. Poorly designed outdoor lighting not only wastes energy, money, and valuable Earth resources, but also robs us of our beautiful night sky. Effects of light pollution on the night sky can be evaluated by the skyglow caused by these artificial lighting sources, through measurements of the night sky brightness (NSB). The Hong Kong Night Sky Brightness Monitoring Network (NSN) was established to monitor in detail the conditions of light pollution in Hong Kong. Monitoring stations were set up throughout the city covering a wide range of urban and rural settings to continuously measure the variations of the NSB. Over 4.6 million night sky measurements were collected from 18 distinct locations between May 2010 and March 2013. This huge dataset, over two thousand times larger than our previous survey [1], forms the backbone for studies of the temporal and geographical variations of this environmental parameter and its correlation with various natural and artificial factors. The concepts and methodology of the NSN were presented here, together with an analysis of the overall night sky conditions in Hong Kong. The average NSB in Hong Kong, excluding data affected by the Moon, was 16.8 mag arcsec-2, or 82 times brighter than the dark site standard established by the International Astronomical Union (IAU) [2]. The urban night sky was on average 15 times brighter than that in a rural location, firmly establishing the effects of artificial lighting sources on the night sky.

  9. Environmental remediation and superhydrophilicity of ultrafine antibacterial tungsten oxide-based nanofibers under visible light source

    NASA Astrophysics Data System (ADS)

    Srisitthiratkul, Chutima; Yaipimai, Wittaya; Intasanta, Varol

    2012-10-01

    Fabrication of nanosilver-decorated WO3 nanofibers was successfully performed. First, deposition of nanosilver onto electrospun WO3 nanofibers' surface was done via photoreduction of silver ion under visible or UV light. The resulting hybrid nanofibers not only revealed antibacterial characteristics but also maintained their photocatalytic performance towards methylene blue decomposition. Unexpectedly, the nanofibrous layers prepared from these nanofibers showed superhydrophilicity under a visible light source. The nanofibers might be advantageous in environmental and hygienic nanofiltration under natural light sources, where the self-cleaning characteristics could be valuable in maintenance processes.

  10. Employing partially coherent, compact gas-discharge sources for coherent diffractive imaging with extreme ultraviolet light

    NASA Astrophysics Data System (ADS)

    Bußmann, J.; Odstrčil, M.; Bresenitz, R.; Rudolf, D.; Miao, Jianwei; Brocklesby, W. S.; Grützmacher, D.; Juschkin, L.

    2015-09-01

    Coherent diffractive imaging (CDI) and related techniques enable a new type of diffraction-limited high-resolution extreme ultraviolet (EUV) microscopy. Here, we demonstrate CDI reconstruction of a complex valued object under illumination by a compact gas-discharge EUV light source emitting at 17.3 nm (O VI spectral line). The image reconstruction method accounts for the partial spatial coherence of the radiation and allows imaging even with residual background light. These results are a first step towards laboratory-scale CDI with a gas-discharge light source for applications including mask inspection for EUV lithography, metrology and astronomy.

  11. Luminescent light source for laser pumping and laser system containing same

    DOEpatents

    Hamil, Roy A.; Ashley, Carol S.; Brinker, C. Jeffrey; Reed, Scott; Walko, Robert J.

    1994-01-01

    The invention relates to a pumping lamp for use with lasers comprising a porous substrate loaded with a component capable of emitting light upon interaction of the component with exciting radiation and a source of exciting radiation. Preferably, the pumping lamp comprises a source of exciting radiation, such as an electron beam, and an aerogel or xerogel substrate loaded with a component capable of interacting with the exciting radiation, e.g., a phosphor, to produce light, e.g., visible light, of a suitable band width and of a sufficient intensity to generate a laser beam from a laser material.

  12. Report of the Basic Energy Sciences Workshop on Compact Light Sources

    SciTech Connect

    Barletta, William A.; Borland, Michael

    2010-05-11

    This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high

  13. Photobiological interactions of blue light and photosynthetic photon flux: effects of monochromatic and broad-spectrum light sources.

    PubMed

    Cope, Kevin R; Snowden, M Chase; Bugbee, Bruce

    2014-01-01

    Photosynthesis (Pn) and photomorphogenesis (Pm) are affected by light quality, light intensity and photoperiod. Although blue light (BL) is necessary for normal development, it is less efficient in driving Pn than other wavelengths of photosynthetically active radiation. The effects of BL on Pm are highly species dependent. Here we report the interacting effects of BL and photosynthetic photon flux (PPF) on growth and development of lettuce, radish and pepper. We used light-emitting diode (LED) arrays to provide BL fractions from 11% to 28% under broad-spectrum white LEDs, and from 0.3% to 92% under monochromatic LEDs. All treatments were replicated three times at each of two PPFs (200 and 500 μmol m(-2) s(-1)). Other than light quality, environmental conditions were uniformly maintained across chambers. Regardless of PPF, BL was necessary to prevent shade-avoidance responses in radish and lettuce. For lettuce and radish, increasing BL reduced stem length, and for both species, there were significant interactions of BL with PPF for leaf expansion. Increasing BL reduced petiole length in radish and flower number in pepper. BL minimally affected pepper growth and other developmental parameters. Pepper seedlings were more photobiologically sensitive than older plants. Surprisingly, there were few interactions between monochromatic and broad-spectrum light sources.

  14. An ALS handbook: A summary of the capabilities and characteristics of the advanced light source

    SciTech Connect

    Not Available

    1989-04-01

    This booklet aims to provide the prospective user of the Advanced Light Source with a concise description of the radiation a researcher might expect at his or her experimental station. The focus is therefore on the characteristics of the light that emerges from insertion devices and bending magnets and on how components of the beam lines further alter the properties of the radiation. The few specifications and operating parameters of the ALS storage ring that are of interest are those that directly determine the radiation characteristics. Sections 4 through 5 are primarily devoted to summary presentations, by means of performance plots and tabular compilations, of radiation characteristics at the ALS--spectral brightness, flux, coherent power, resolution, etc.--assuming a representative set of three undulators and one wiggler and a corresponding set of four beam lines. As a complement to these performance summaries, Section 1 is a general introductory discussion of synchrotron radiation and the ALS, and Section 2 discusses the properties of the stored electron beam that affect the radiation. Section 3 then provides an introduction to the characteristics of synchrotron radiation from bending magnets, wigglers, and undulators. In addition, Section 5 briefly introduces the theory of diffraction-grating and crystal monochromators. As compared with previous editions of this booklet, the performance plots and tabular compilations of the ALS radiation characteristics are now based on conservative engineering designs rather than preliminary physics designs.

  15. Polymer nanofibers as novel light-emitting sources and lasing material

    NASA Astrophysics Data System (ADS)

    Camposeo, A.; Persano, L.; Pisignano, D.

    2013-09-01

    Polymer micro- and nano-fibers, made of organic light-emitting materials with optical gain, show interesting lasing properties. Fibers with diameters from few tens of nm to few microns can be fabricated by electrospinning, a method based on electrostatic fields applied to a polymer solution. The morphology and emission properties of these fibers, composed of optically inert polymers embedding laser dyes, are characterized by scanning electron and fluorescence microscopy, and lasing is observed under optical pumping for fluences of the order of 102 μJ cm-2. In addition, lightemitting fibers can be electrospun by conjugated polymers, their blends, and other active organics, and can be exploited in a range of photonic and electronic devices. In particular, waveguiding of light is observed and characterized, showing optical loss coefficient in the range of 102-103 cm-1. The reduced size of these novel laser systems, combined with the possibility of achieving wavelength tunability through transistor or other electrode-based architectures embedding nonlinear molecular layers, and with their peculiar mechanical robustness, open interesting perspectives for realizing miniaturized laser sources to integrate on-chip optical sensors and photonic circuits.

  16. A new on-axis multimode spectrometer for the macromolecular crystallography beamlines of the Swiss Light Source

    PubMed Central

    Owen, Robin L.; Pearson, Arwen R.; Meents, Alke; Boehler, Pirmin; Thominet, Vincent; Schulze-Briese, Clemens

    2009-01-01

    X-ray crystallography at third-generation synchrotron sources permits tremendous insight into the three-dimensional structure of macromolecules. Additional information is, however, often required to aid the transition from structure to function. In situ spectroscopic methods such as UV–Vis absorption and (resonance) Raman can provide this, and can also provide a means of detecting X-ray-induced changes. Here, preliminary results are introduced from an on-axis UV–Vis absorption and Raman multimode spectrometer currently being integrated into the beamline environment at X10SA of the Swiss Light Source. The continuing development of the spectrometer is also outlined. PMID:19240329

  17. Light source design using Kagome-lattice hollow core photonic crystal fibers

    NASA Astrophysics Data System (ADS)

    Hossain, Md. Anwar; Namihira, Yoshinori

    2014-09-01

    Supercontinuum (SC) light source is designed using high pressure Xe-filled hollow core Kagome-lattice photonic crystal fiber. Using finite element method with perfectly matched layer, SC spectra in normal chromatic dispersion region have been generated using picosecond optical pulses from relatively less expensive laser sources.

  18. 100W EUV light-source key component technology update for HVM

    NASA Astrophysics Data System (ADS)

    Hori, Tsukasa; Kawasuji, Yasufumi; Tanaka, Hiroshi; Watanabe, Yukio; Shiraishi, Yutaka; Abe, Tamotsu; Okamoto, Takeshi; Kodama, Takeshi; Nakarai, Hiroaki; Yamazaki, Taku; Okazaki, Shinji; Saitou, Takashi; Mizoguchi, Hakaru

    2016-03-01

    Gigaphoton Inc. develops a high-power laser produced plasma extreme ultraviolet (LPP EUV) light source for high volume manufacturing which enables sub-10nm critical layer patterning for semiconductor device fabrication. A technology update of key components of a 100 W LPP-EUV light source is given in this paper. The key components efficiently produce a stable plasma and evacuate the tin debris from the EUV vessel with a magnetic debris mitigation system. The chosen technology guarantees therefore a high-power and long-life EUV light source system. Each component is described with updated data. The latest system performance results are also presented. They were obtained from our proto LPP-EUV light systems which support 100 W output power.

  19. Styrofoam Debris as a Source of Hazardous Additives for Marine Organisms.

    PubMed

    Jang, Mi; Shim, Won Joon; Han, Gi Myung; Rani, Manviri; Song, Young Kyoung; Hong, Sang Hee

    2016-05-17

    There is growing concern over plastic debris and their fragments as a carrier for hazardous substances in marine ecosystem. The present study was conducted to provide field evidence for the transfer of plastic-associated chemicals to marine organisms. Hexabromocyclododecanes (HBCDs), brominated flame retardants, were recently detected in expanded polystyrene (styrofoam) marine debris. We hypothesized that if styrofoam debris acts as a source of the additives in the marine environment, organisms inhabiting such debris might be directly influenced by them. Here we investigated the characteristics of HBCD accumulation by mussels inhabiting styrofoam. For comparison, mussels inhabiting different substrates, such as high-density polyethylene (HDPE), metal, and rock, were also studied. The high HBCD levels up to 5160 ng/g lipid weight and the γ-HBCD dominated isomeric profiles in mussels inhabiting styrofoam strongly supports the transfer of HBCDs from styrofoam substrate to mussels. Furthermore, microsized styrofoam particles were identified inside mussels, probably originating from their substrates.

  20. Styrofoam Debris as a Source of Hazardous Additives for Marine Organisms.

    PubMed

    Jang, Mi; Shim, Won Joon; Han, Gi Myung; Rani, Manviri; Song, Young Kyoung; Hong, Sang Hee

    2016-05-17

    There is growing concern over plastic debris and their fragments as a carrier for hazardous substances in marine ecosystem. The present study was conducted to provide field evidence for the transfer of plastic-associated chemicals to marine organisms. Hexabromocyclododecanes (HBCDs), brominated flame retardants, were recently detected in expanded polystyrene (styrofoam) marine debris. We hypothesized that if styrofoam debris acts as a source of the additives in the marine environment, organisms inhabiting such debris might be directly influenced by them. Here we investigated the characteristics of HBCD accumulation by mussels inhabiting styrofoam. For comparison, mussels inhabiting different substrates, such as high-density polyethylene (HDPE), metal, and rock, were also studied. The high HBCD levels up to 5160 ng/g lipid weight and the γ-HBCD dominated isomeric profiles in mussels inhabiting styrofoam strongly supports the transfer of HBCDs from styrofoam substrate to mussels. Furthermore, microsized styrofoam particles were identified inside mussels, probably originating from their substrates. PMID:27100560

  1. Sampling Scarab Beetles in Tropical Forests: The Effect of Light Source and Night Sampling Periods

    PubMed Central

    García-López, Alejandra; Micó, Estefanía; Zumbado, Manuel A.; Galante, Eduardo

    2011-01-01

    Light traps have been used widely to sample insect abundance and diversity, but their performance for sampling scarab beetles in tropical forests based on light source type and sampling hours throughout the night has not been evaluated. The efficiency of mercury-vapour lamps, cool white light and ultraviolet light sources in attracting Dynastinae, Melolonthinae and Rutelinae scarab beetles, and the most adequate period of the night to carry out the sampling was tested in different forest areas of Costa Rica. Our results showed that light source wavelengths and hours of sampling influenced scarab beetle catches. No significant differences were observed in trap performance between the ultraviolet light and mercury-vapour traps, whereas these two methods caught significantly more species richness and abundance than cool white light traps. Species composition also varied between methods. Large differences appear between catches in the sampling period, with the first five hours of the night being more effective than the last five hours. Because of their high efficiency and logistic advantages, we recommend ultraviolet light traps deployed during the first hours of the night as the best sampling method for biodiversity studies of those scarab beetles in tropical forests. PMID:22208730

  2. The Nanoscience Beamline (I06) at Diamond Light Source

    SciTech Connect

    Dhesi, S. S.; Cavill, S. A.; Potenza, A.; Marchetto, H.; Mott, R. A.; Steadman, P.; Peach, A.; Shepherd, E. L.; Ren, X.; Wagner, U. H.; Reininger, R.

    2010-06-23

    The Nanoscience beamline (I06) is one of seven Diamond Phase-I beamlines which has been operational since January 2007 delivering polarised soft x-rays, for a PhotoEmission Electron Microscope (PEEM) and branchline, in the energy range 80-2100 eV. The beamline is based on a collimated plane grating monochromator with sagittal focusing elements, utilising two APPLE II helical undulator sources, and has been designed for high flux density at the PEEM sample position. A {approx}5 {mu}m ({sigma}) diameter beam is focussed onto the sample in the PEEM allowing a range of experiments using x-ray absorption spectroscopy (XAS), x-ray magnetic circular dichroism (XMCD) and x-ray magnetic linear dichroism (XMLD) as contrast mechanisms. The beamline is also equipped with a branchline housing a 6T superconducting magnet for XMCD and XMLD experiments. The magnet is designed to move on and off the branchline which allows a diverse range of experiments.

  3. A method for characterizing the stability of light sources.

    PubMed

    Sanvito, Tiziano; Zocca, Francesca; Pullia, Alberto; Potenza, Marco

    2013-10-21

    We describe a method for measuring small fluctuations in the intensity of a laser source with a resolution of 10⁻⁴. The current signal generated by a PIN diode is passed to a front-end electronics that discriminates the AC from the DC components, which are physically separated and propagated along circuit paths with different gains. The gain long the AC signal path is set one order of magnitude larger than that along the DC signal path in such a way to optimize the measurement dynamic range. We then derive the relative fluctuation signal by normalizing the input-referred AC signal component to its input-referred DC counterpart. In this way the fluctuation of the optical signal waveform relative to the mean power of the laser is obtained. A "Noise-Scattering-Pattern method" and a "Signal-Power-Spectrum method" are then used to analyze the intensity fluctuations from three different solid-state lasers. This is a powerful tool for the characterization of the intensity stability of lasers. Applications are discussed. PMID:24150307

  4. A syncrhronized FIR/VUV light source at Jefferson Lab

    SciTech Connect

    Shinn, Michelle D.

    2013-05-31

    This slide show presents an introduction to Free-Electron Lasers (FELs) and what makes the JLab FELs unique. Ways of exploring the nature of matter with the FEL are shown, including applications in the THz, IR, UV, and VUV. The Jefferson Lab FEL Facility is unique in its high average brightness in the THz, and IR -- VUV spectral regions and Sub ps-pulses at MHz repetition rates. With an installation of a rebuilt 'F100' cryomodule the linac energy will increase to > 150MeV. This will permit lasing further into the UV and extend VUV. With the swap of our CEBAF-style cryounit for an improved booster, we could lase in the VUV. Addition of a wiggler and optical cavity slightly canted from the UV beamline would allow simultaneous lasing of UV and THz for high E-field 2 color experiments.

  5. 14 CFR 61.419 - How do I obtain privileges to provide training in an additional category or class of light-sport...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... training in an additional category or class of light-sport aircraft? 61.419 Section 61.419 Aeronautics and... How do I obtain privileges to provide training in an additional category or class of light-sport... training in an additional category or class of light-sport aircraft you must— (a) Receive a...

  6. Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources

    NASA Technical Reports Server (NTRS)

    McAndrew, Brendan; Cooper, John; Arecchi, Angelo; McKee, Greg; Durell, Christopher

    2012-01-01

    Stable high radiance in visible and near-ultraviolet wavelengths is desirable for radiometric calibration sources. In this work, newly available electrodeless radio-frequency (RF) driven plasma light sources were combined with research grade, low-noise power supplies and coupled to an integrating sphere to produce a uniform radiance source. The stock light sources consist of a 28 VDC power supply, RF driver, and a resonant RF cavity. The RF cavity includes a small bulb with a fill gas that is ionized by the electric field and emits light. This assembly is known as the emitter. The RF driver supplies a source of RF energy to the emitter. In commercial form, embedded electronics within the RF driver perform a continual optimization routine to maximize energy transfer to the emitter. This optimization routine continually varies the light output sinusoidally by approximately 2% over a several-second period. Modifying to eliminate this optimization eliminates the sinusoidal variation but allows the output to slowly drift over time. This drift can be minimized by allowing sufficient warm-up time to achieve thermal equilibrium. It was also found that supplying the RF driver with a low-noise source of DC electrical power improves the stability of the lamp output. Finally, coupling the light into an integrating sphere reduces the effect of spatial fluctuations, and decreases noise at the output port of the sphere.

  7. Stray light reduction in optical computed tomography using a convergent cone-beam source

    NASA Astrophysics Data System (ADS)

    Jordan, Kevin; Dekker, Kurtis; Battista, Jerry

    2015-01-01

    The planar diffuser light source for a cone-beam optical CT scanner was replaced with a filtered LED and large Fresnel lens. The source was focused on a camera and convergent cone-beam images were acquired. Images are sensitive to mismatches in the refractive index of vessels, samples and matching liquid. For PETE jars and water solutions, a loss of approximately 30% of the projections was demonstrated. Teflon PFA cylinders provided better refractive index matching and more accurate reconstructions. The convergent cone-beam source dramatically increased imaging efficiency by a factor of 1000 and reduced stray light levels by confining illumination to image forming rays.

  8. Synchrotron light source data book: Version 4, Revision 05/96

    SciTech Connect

    Murphy, J.B.

    1996-05-01

    This book is as its name implies a collection of data on existing and planned synchrotron light sources. The intention was to provide a compendium of tools for the design of electron storage rings as synchrotron radiation sources. The slant is toward the accelerator physicist as other booklets such as the X-Ray Data Booklet address the use of synchrotron radiation. It is hoped that the booklet serves as a pocket sized reference to facilitate back of the envelope type calculations. It contains some useful formulae in practical units and a brief description of many of the existing and planned light source lattices.

  9. GAMMA-RAY COMPTON LIGHT SOURCE DEVELOPMENT AT LLNL

    SciTech Connect

    Hartemann, F V; Anderson, S G; Gibson, D J; Hagmann, C A; Johnson, M S; Jovanovic, I; Messerly, M J; Pruet, J A; Shverdin, M Y; Tremaine, A M; McNabb, D P; Siders, C W; Barty, C J

    2007-08-15

    A new class of tunable, monochromatic {gamma}-ray sources capable of operating at high peak and average brightness is currently being developed at LLNL for nuclear photoscience and applications. These novel systems are based on Compton scattering of laser photons by a high brightness relativistic electron beam produced by an rf photoinjector. A prototype, capable of producing > 10{sup 8} 0.7 MeV photons in a single shot, with a fractional bandwidth of 1%, and a repetition rate of 10 Hz, is currently under construction at LLNL; this system will be used to perform nuclear resonance fluorescence experiments. A new symmetrized S-band rf gun, using a Mg photocathode, will produce up to 1 nC of charge in an 8 ps bunch, with a normalized emittance modeled at 0.8 mm.mrad; electrons are subsequently accelerated up to 120 MeV to interact with a 500 mJ, 10 ps, 355 nm laser pulse and generate {gamma}-rays. The laser front end is a fiber-based system, using corrugated-fiber Bragg gratings for stretching, and drives both the frequency-quadrupled photocathode illumination laser and the Nd:YAG interaction laser. Two new technologies are used in the laser: a hyper-Michelson temporal pulse stacker capable of producing 8 ps square UV pulses, and a hyper-dispersion compressor for the interaction laser. Other key technologies, basic scaling laws, and recent experimental results will also be presented, along with an overview of future research and development directions.

  10. Dual Fiber-Optic Fabry-Perot Interferometer Temperature Sensor with Low-Cost Light-Emitting Diode Light Source

    NASA Astrophysics Data System (ADS)

    Wang, Mu-Chun; Hsieh, Zhen-Ying; Tseng, Yuan-Tai; Tseng, Fan-Gang; Huang, Heng-Sheng; Wang, Jon-En; Taylor, Henry F.

    2008-04-01

    A dual fiber-optic Fabry-Perot interferometer (FFPI) sensor system with a low-coherence communication-system light-emitting diode (LED) as a light source is investigated to detect temperature variation signals. In this system, there are two FFPIs: the sensing and reference FFPIs. When the perturbation of interest, such as that of temperature, disturbs the sensing FFPI to produce a phase shift, the light reflected from the sensor is demodulated by the reference FFPI to extract the measurand. A low-power (sub-nW) optical signal is converted into an electrical signal and processed by a designed optical receiver. This setup is availably applied in biosensors to compensate the temperature variation in a sensing environment or sense the temperature effect in a certain measurement on an interior local site.

  11. Visible Light-Driven Atom Transfer Radical Addition to Olefins using Bi2 O3 as Photocatalyst.

    PubMed

    Riente, Paola; Pericàs, Miquel A

    2015-06-01

    Bismuth oxide, an inexpensive and non-toxic semiconductor, has been successfully used as a visible light photocatalyst for the atom transfer radical addition (ATRA) reaction of organobromides to diversely functionalized terminal olefins. The reaction takes place under very mild conditions, in the absence of any additive, and with low catalyst loading (1 mol %). The corresponding ATRA products are obtained with moderate to excellent yields (up to 95 %). PMID:25925199

  12. Means to improve light source productivity: from proof of concept to field implementation

    NASA Astrophysics Data System (ADS)

    Rausa, E.; Cacouris, T.; Conley, W.; Jackson, M.; Luo, S.; Murthy, S.; Rechtsteiner, G.; Steiner, K.

    2016-03-01

    Light source technological performance is key to enabling chipmaker yield and production success. Just as important is ensuring that performance is consistent over time to help maintain as high an uptime as possible on litho-cells (scanner and track combination). While it is common to see average tool uptime of over 99% based on service intervention time, we will show that there are opportunities to improve equipment availability through a multifaceted approach that can deliver favorable results and significantly improve on the actual production efficiency of equipment. The majority of chipmakers are putting light source data generated by tools such as Cymer OnLine (COL), OnPulse Plus, and SmartPulse to good use. These data sets, combined with in-depth knowledge of the equipment, makes it possible to draw powerful conclusions that help increase both chip manufacturing consistency as well as equipment productivity. This discussion will focus on the latter, equipment availability, and how data analysis can help increase equipment availability for Cymer customers. There are several types of opportunities for increasing equipment availability, but in general we can focus on two primary categories: 1) scheduled downtime and 2) unscheduled downtime. For equipment that is under control of a larger entity, as the laser is to the scanner, there are additional categories related to either communication errors or better synchronization of events that can maximize overall litho-cell efficiency. In this article we will focus on general availability without highlighting the specific cause of litho-cell (laser, scanner and track). The goal is to increase equipment available time with a primary focus is on opportunities to minimize errors and variabilities.

  13. Satellite-mounted Light Source as Photometric Calibration Standards

    NASA Astrophysics Data System (ADS)

    Albert, J.; Burgett, W.; Rhodes, J.; Battat, J.

    At AMOS 2006 we proposed a tunable laser-based satellite-mounted spectrophotometric and absolute flux calibration system, to be utilized by ground- and space-based telescopes, for precision calibration of ground-based telescope photometry and flux. Since then, we have performed a campaign of observations of the 532 nm pulsed laser aboard the CALIPSO satellite (launched Apr. 2006), using a portable network of cameras and NIST-calibrated photodiodes, to test the precision of this method of measuring atmospheric extinction. This technique has astrophysical applications including reducing a major systematic uncertainty (absolute photometry) on cosmological parameter measurement using type Ia supernovae, as well as in upcoming photometric red shift surveys measuring growth of large scale structure in the Universe. In addition, upcoming systems potentially have broad utility for defense and national security applications such as ground target illumination and space communication. We will report on our measurements using our observations of the CALIPSO laser, and discuss future directions and applications. For further details please see http://www.arxiv.org/abs/astro-ph/0604339 and http://www8.nationalacademies.org/astro2010/DetailFileDisplay.aspx?id=546.

  14. Preparation and characterization of B4C coatings for advanced research light sources.

    PubMed

    Störmer, Michael; Siewert, Frank; Sinn, Harald

    2016-01-01

    X-ray optical elements are required for beam transport at the current and upcoming free-electron lasers and synchrotron sources. An X-ray mirror is a combination of a substrate and a coating. The demand for large mirrors with single layers consisting of light or heavy elements has increased during the last few decades; surface finishing technology is currently able to process mirror lengths up to 1 m with microroughness at the sub-nanometre level. Additionally, thin-film fabrication is able to deposit a suitable single-layer material, such as boron carbide (B4C), some tens of nanometres thick. After deposition, the mirror should provide excellent X-ray optical properties with respect to coating thickness errors, microroughness values and slope errors; thereby enabling the mirror to transport the X-ray beam with high reflectivity, high beam flux and an undistorted wavefront to an experimental station. At the European XFEL, the technical specifications of the future mirrors are extraordinarily challenging. The acceptable shape error of the mirrors is below 2 nm along the whole length of 1 m. At the Helmholtz-Zentrum Geesthacht (HZG), amorphous layers of boron carbide with thicknesses in the range 30-60 nm were fabricated using the HZG sputtering facility, which is able to cover areas up to 1500 mm long by 120 mm wide in one step using rectangular B4C sputtering targets. The available deposition area is suitable for the specified X-ray mirror dimensions of upcoming advanced research light sources such as the European XFEL. The coatings produced were investigated by means of X-ray reflectometry and interference microscopy. The experimental results for the B4C layers are discussed according to thickness uniformity, density, microroughness and thermal stability. The variation of layer thickness in the tangential and sagittal directions was investigated in order to estimate the achieved level of uniformity over the whole deposition area, which is considerably

  15. Preparation and characterization of B4C coatings for advanced research light sources

    PubMed Central

    Störmer, Michael; Siewert, Frank; Sinn, Harald

    2016-01-01

    X-ray optical elements are required for beam transport at the current and upcoming free-electron lasers and synchrotron sources. An X-ray mirror is a combination of a substrate and a coating. The demand for large mirrors with single layers consisting of light or heavy elements has increased during the last few decades; surface finishing technology is currently able to process mirror lengths up to 1 m with microroughness at the sub-nanometre level. Additionally, thin-film fabrication is able to deposit a suitable single-layer material, such as boron carbide (B4C), some tens of nanometres thick. After deposition, the mirror should provide excellent X-ray optical properties with respect to coating thickness errors, microroughness values and slope errors; thereby enabling the mirror to transport the X-ray beam with high reflectivity, high beam flux and an undistorted wavefront to an experimental station. At the European XFEL, the technical specifications of the future mirrors are extraordinarily challenging. The acceptable shape error of the mirrors is below 2 nm along the whole length of 1 m. At the Helmholtz-Zentrum Geesthacht (HZG), amorphous layers of boron carbide with thicknesses in the range 30–60 nm were fabricated using the HZG sputtering facility, which is able to cover areas up to 1500 mm long by 120 mm wide in one step using rectangular B4C sputtering targets. The available deposition area is suitable for the specified X-ray mirror dimensions of upcoming advanced research light sources such as the European XFEL. The coatings produced were investigated by means of X-ray reflectometry and interference microscopy. The experimental results for the B4C layers are discussed according to thickness uniformity, density, microroughness and thermal stability. The variation of layer thickness in the tangential and sagittal directions was investigated in order to estimate the achieved level of uniformity over the whole deposition area, which is

  16. Preparation and characterization of B4C coatings for advanced research light sources.

    PubMed

    Störmer, Michael; Siewert, Frank; Sinn, Harald

    2016-01-01

    X-ray optical elements are required for beam transport at the current and upcoming free-electron lasers and synchrotron sources. An X-ray mirror is a combination of a substrate and a coating. The demand for large mirrors with single layers consisting of light or heavy elements has increased during the last few decades; surface finishing technology is currently able to process mirror lengths up to 1 m with microroughness at the sub-nanometre level. Additionally, thin-film fabrication is able to deposit a suitable single-layer material, such as boron carbide (B4C), some tens of nanometres thick. After deposition, the mirror should provide excellent X-ray optical properties with respect to coating thickness errors, microroughness values and slope errors; thereby enabling the mirror to transport the X-ray beam with high reflectivity, high beam flux and an undistorted wavefront to an experimental station. At the European XFEL, the technical specifications of the future mirrors are extraordinarily challenging. The acceptable shape error of the mirrors is below 2 nm along the whole length of 1 m. At the Helmholtz-Zentrum Geesthacht (HZG), amorphous layers of boron carbide with thicknesses in the range 30-60 nm were fabricated using the HZG sputtering facility, which is able to cover areas up to 1500 mm long by 120 mm wide in one step using rectangular B4C sputtering targets. The available deposition area is suitable for the specified X-ray mirror dimensions of upcoming advanced research light sources such as the European XFEL. The coatings produced were investigated by means of X-ray reflectometry and interference microscopy. The experimental results for the B4C layers are discussed according to thickness uniformity, density, microroughness and thermal stability. The variation of layer thickness in the tangential and sagittal directions was investigated in order to estimate the achieved level of uniformity over the whole deposition area, which is considerably

  17. Radiological implications of top-off operation at national synchrotron light source-II

    NASA Astrophysics Data System (ADS)

    Job, P. K.; Casey, W. R.

    2011-08-01

    High current and low emittance have been specified to achieve ultra high brightness in the third generation medium energy Synchrotron Radiation Sources. This leads to the electron beam lifetime limited by Touschek scattering, and after commissioning may settle in at as low as ∼3 h. It may well be less in the early days of operation. At the same time, the intensity stability specified by the user community for the synchrotron beam is 1% or better. Given the anticipated lifetime of the beam, incremental filling called top-off injection at intervals on the order of ∼1 min will be required to maintain this beam stability. It is judged to be impractical to make these incremental fills by closing the beam shutters at each injection. In addition, closing the front end beam shutters during each injection will adversely affect the stability of beamline optics due to thermal cycling. Hence the radiological consequences of injection with front end beam shutters open must be evaluated. This paper summarizes results of radiological analysis carried out for the proposed top-off injection at National Synchrotron Light Source-II (NSLS-II) with beam shutters open.

  18. Technical options for processing additional light tight oil volumes within the United States

    EIA Publications

    2015-01-01

    This report examines technical options for processing additional LTO volumes within the United States. Domestic processing of additional LTO would enable an increase in petroleum product exports from the United States, already the world’s largest net exporter of petroleum products. Unlike crude oil, products are not subject to export limitations or licensing requirements. While this is one possible approach to absorbing higher domestic LTO production in the absence of a relaxation of current limitations on crude exports, domestic LTO would have to be priced at a level required to encourage additional LTO runs at existing refinery units, debottlenecking, or possible additions of processing capacity.

  19. Apparatus and method for compensating for electron beam emittance in synchronizing light sources

    DOEpatents

    Neil, G.R.

    1996-07-30

    A focused optical beam is used to change the path length of the core electrons in electron light sources thereby boosting their efficiency of conversion of electron beam energy to light. Both coherent light in the free electron laser and incoherent light in the synchrotron is boosted by this technique. By changing the path length of the core electrons by the proper amount, the core electrons are caused to stay in phase with the electrons in the outer distribution of the electron beam. This increases the fraction of the electron beam energy that is converted to light thereby improving the efficiency of conversion of energy to light and therefore boosting the power output of the free electron laser and synchrotron. 4 figs.

  20. Apparatus and method for compensating for electron beam emittance in synchronizing light sources

    DOEpatents

    Neil, George R.

    1996-01-01

    A focused optical beam is used to change the path length of the core electrons in electron light sources thereby boosting their efficiency of conversion of electron beam energy to light. Both coherent light in the free electron laser and incoherent light in the synchrotron is boosted by this technique. By changing the path length of the core electrons by the proper amount, the core electrons are caused to stay in phase with the electrons in the outer distribution of the electron beam. This increases the fraction of the electron beam energy that is converted to light thereby improving the efficiency of conversion of energy to light and therefore boosting the power output of the free electron laser and synchrotron.

  1. Computer simulation of PPF distribution under blue and red LED light source for plant growth.

    PubMed

    Takita, S; Okamoto, K; Yanagi, T

    1996-12-01

    The superimposed pattern of "luminescence spectrum of blue light emitting diode (LED)" and "that of red LED", corresponds well to light absorption spectrum of chlorophyll. If these two kinds of LED are used as a light source, various plant cultivation experiments are possible. The cultivation experiments which use such light sources are becoming increasingly active, and in such experiments, it is very important to know the distribution of the photosynthetic photon flux (PPF) which exerts an important influence on photosynthesis. Therefore, we have developed a computer simulation system which can visualize the PPF distribution under a light source equipped with blue and red LEDs. In this system, an LED is assumed to be a point light source, and only the photons which are emitted directly from LED are considered. This simulation system can display a perspective view of the PPF distribution, a transverse and a longitudinal section of the distribution, and a contour map of the distribution. Moreover, a contour map of the ratio of the value of the PPF emitted by blue LEDs to that by blue and red LEDs can be displayed. As the representation is achieved by colored lines according to the magnitudes of the PPF in our system, a user can understand and evaluate the state of the PPF well.

  2. Temporal dark adaptation to spatially complex backgrounds: effect of an additional light source.

    PubMed

    Stokkermans, M G M; Heynderickx, I E J

    2014-07-01

    Visual adaptation (and especially dark adaptation) has been studied extensively in the past, however, mainly addressing adaptation to fully dark backgrounds. At this stage, it is unclear whether these results are not too simple to be applied to complex situations, such as predicting adaptation of a motorist driving at night. To fill this gap we set up a study investigating how spatially complex backgrounds influence temporal dark adaptation. Our results showed that dark adaptation to spatially complex backgrounds leads to much longer adaptation times than dark adaptation to spatially uniform backgrounds. We conclude therefore that the adaptation models based on past studies overestimate the visual system's sensitivity to detect luminance variations in spatially complex environments. Our results also showed large variations in adaptation times when varying the degree of spatial complexity of the background. Hence, we may conclude that it is important to take into account models that are based on spatially complex backgrounds when predicting dark adaptation for complex environments.

  3. UV light-mediated difunctionalization of alkenes through aroyl radical addition/1,4-/1,2-aryl shift cascade reactions.

    PubMed

    Zheng, Lewei; Huang, Hongli; Yang, Chao; Xia, Wujiong

    2015-02-20

    UV light-mediated difunctionalization of alkenes through an aroyl radical addition/1,4-/1,2-aryl shift has been described. The resulted aroyl radical from a photocleavage reaction added to acrylamide compounds followed by cyclization led to the formation of oxindoles, whereas the addition to cinnamic amides aroused a unique 1,4-aryl shift reaction. Furthermore, the difunctionalization of alkenes of prop-2-en-1-ols was also achieved through aroyl radical addition and a sequential 1,2-aryl shift cascade reaction.

  4. Biomass estimator for NIR image with a few additional spectral band images taken from light UAS

    NASA Astrophysics Data System (ADS)

    Pölönen, Ilkka; Salo, Heikki; Saari, Heikki; Kaivosoja, Jere; Pesonen, Liisa; Honkavaara, Eija

    2012-05-01

    A novel way to produce biomass estimation will offer possibilities for precision farming. Fertilizer prediction maps can be made based on accurate biomass estimation generated by a novel biomass estimator. By using this knowledge, a variable rate amount of fertilizers can be applied during the growing season. The innovation consists of light UAS, a high spatial resolution camera, and VTT's novel spectral camera. A few properly selected spectral wavelengths with NIR images and point clouds extracted by automatic image matching have been used in the estimation. The spectral wavelengths were chosen from green, red, and NIR channels.

  5. Beam-based model of broad-band impedance of the Diamond Light Source

    NASA Astrophysics Data System (ADS)

    Smaluk, Victor; Martin, Ian; Fielder, Richard; Bartolini, Riccardo

    2015-06-01

    In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS) to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  6. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    SciTech Connect

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-05-05

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

  7. Recent Beam Measurements and New Instrumentation at the Advanced Light Source

    SciTech Connect

    Sannibale, F.; Baptiste, K.; Barry, W.; Chin, M.; Filippetto, D.; Jaegerhofer, L.; Julian, J.; Kwiatkowski, S.; Low, R.; Plate, D.; Portmann, G.; Robin, D.; Scarvie, T.; Stupakov, G.; Weber, J.; Zolotorev, M.; /LBL, Berkeley

    2012-04-11

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

  8. Interferometric broadband Fourier spectroscopy with a partially coherent gas-discharge extreme ultraviolet light source.

    PubMed

    Rudolf, Denis; Bußmann, Jan; Odstrčil, Michal; Dong, Minjie; Bergmann, Klaus; Danylyuk, Serhiy; Juschkin, Larissa

    2015-06-15

    Extreme ultraviolet (EUV) spectroscopy is a powerful tool for studying fundamental processes in plasmas as well as for spectral characterization of EUV light sources and EUV optics. However, a simultaneous measurement covering a broadband spectral range is difficult to realize. Here, we propose a method for interferometric broadband Fourier spectroscopy connecting soft x ray and visible spectral ranges with moderate spectral resolution. We present an analytical model to recover the spectrum from a double-slit interferogram. We apply our model for spectral characterization of a partially coherent gas-discharge EUV light source operated with different gases in the spectral range between 10 and 110 nm wavelengths. Our approach allows a simple and fast broadband spectroscopy with fully or partially spatially coherent light sources, for instance, to characterize out-of-band radiation in EUV lithography applications. PMID:26076270

  9. Measurements of a prototype synchrotron radiation pumped absorber for future light sources

    SciTech Connect

    Chou, T.S.; Foerster, C.L.; Halama, H.; Lanni, C.

    1988-01-01

    In the new generation of advanced synchrotron light sources, the conventional concept of distributed pumping is no longer suitable for removing the gas load caused by photon stimulated desorption (PSD). A new concept using a combination of photon absorber and pumping station has been designed, constructed, and installed in the U1OB beam line at the VUV ring of the National Synchrotron Light Source. The system consists of an electrically insulated water cooled copper block, a titanium sublimation pump, calibrated BA gauges, a calibrated RGA, and a known conductance. A photon beam 10 milliradian wide and 3.26 milliradian high, having critical energy of 500 eV, is directed on the absorber. PSD yield is studied as a function of total beam dose and absorber surface preparation. The results from this experiment, pump characteristics, design of an absorber pump for future light sources, and the pressure improvement factors will be presented. 5 refs., 7 figs., 1 tab.

  10. Irradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source

    NASA Astrophysics Data System (ADS)

    Morrill, J. S.; McMullin, D.; Floyd, L. E.; Lorentz, S. R.; Korendyke, C. M.

    2009-12-01

    Total solar irradiance measurements have been made from space based instruments for the past several decades. Due to a variety of reasons which range from instrumental degradation to differences in optical design, the data from these sources have proved difficult to overlap and place on an absolute scale. Some previous calibration efforts have used the sun as a source while operating the instrument in a large vacuum chamber. More recent efforts to provide ground based, pre-flight intercomparisons between flight radiometers and recently developed high power cryogenic radiometers using lasers. We are currently developing a calibration facility at The Naval Research Laboratory which uses a high power cryogenic radiometer with a broadband light source with near solar illumination. The system uses a very low scattered light vacuum calibration tank used to perform the stray light tests of the LASCO and SECCHI coronagraphs on the SOHO and STEREO missions. This presentation will address the status of our system, recent measurements, and future plans.

  11. Enhancement for Φ-OTDR performance by using narrow linewidth light source and signal processing

    NASA Astrophysics Data System (ADS)

    Zhang, Meng; Wang, Song; Zheng, Yuanwei; Yang, Yao; Sa, Xingjie; Zhang, Li

    2016-03-01

    In order to enhance the signal-to-noise-ratio of a distributed acoustic sensing system based on phase-sensitive optical time-domain reflectometry (Φ-OTDR), we have proposed a combination of segmented unwrapping algorithm, averaging estimation of phase difference, and infinite impulse response (IIR) filtering method. The enhancement of signal quality is numerically demonstrated. Moreover, we have studied the influence resulted from the light source noise on the Φ-OTDR performance. The result has shown that when the linewidth of light source used in the Φ-OTDR system is narrower, the performance of the system is better. In a word, such a Φ-OTDR system could obtain higher quality demodulated signals when the narrower linewidth light source is chosen and the method of averaging estimation phase difference is used.

  12. SPIM-fluid: open source light-sheet based platform for high-throughput imaging.

    PubMed

    Gualda, Emilio J; Pereira, Hugo; Vale, Tiago; Estrada, Marta Falcão; Brito, Catarina; Moreno, Nuno

    2015-11-01

    Light sheet fluorescence microscopy has recently emerged as the technique of choice for obtaining high quality 3D images of whole organisms/embryos with low photodamage and fast acquisition rates. Here we present an open source unified implementation based on Arduino and Micromanager, which is capable of operating Light Sheet Microscopes for automatized 3D high-throughput imaging on three-dimensional cell cultures and model organisms like zebrafish, oriented to massive drug screening. PMID:26601007

  13. SPIM-fluid: open source light-sheet based platform for high-throughput imaging

    PubMed Central

    Gualda, Emilio J.; Pereira, Hugo; Vale, Tiago; Estrada, Marta Falcão; Brito, Catarina; Moreno, Nuno

    2015-01-01

    Light sheet fluorescence microscopy has recently emerged as the technique of choice for obtaining high quality 3D images of whole organisms/embryos with low photodamage and fast acquisition rates. Here we present an open source unified implementation based on Arduino and Micromanager, which is capable of operating Light Sheet Microscopes for automatized 3D high-throughput imaging on three-dimensional cell cultures and model organisms like zebrafish, oriented to massive drug screening. PMID:26601007

  14. Elite sport is not an additional source of distress for adolescents with high stress levels.

    PubMed

    Gerber, Markus; Holsboer-Trachsler, Edith; Pühse, Uwe; Brand, Serge

    2011-04-01

    This study examined whether participation in elite sport interacts with stress in decreasing or increasing symptoms of depression and anxiety among adolescents, and further, whether the interplay between participation in high-performance sport and stress is related to the perceived quality of sleep. 434 adolescents (278 girls, 156 boys; age: M = 17.2 yr.) from 15 "Swiss Olympic Sport Classes" and 9 conventional classes answered a questionnaire and completed a 7-day sleep log. Analyses of covariance showed that heightened stress was related to more depressive symptoms and higher scores for trait-anxiety. Moreover, those classified as having poor sleep by a median split cutoff reported higher levels of depressive symptoms. No significant (multivariate) main effects were found for high-performance sport athletes. Similarly, no significant two- or three-way interaction effects were found. These results caution against exaggerated expectations concerning sport participation as a stress buffer. Nevertheless, participation in high-performance sport was not found to be an additional source of distress for adolescents who reported high stress levels despite prior research that has pointed toward such a relationship.

  15. Classification of light sources and their interaction with active and passive environments

    SciTech Connect

    El-Dardiry, Ramy G. S.; Faez, Sanli; Lagendijk, Ad

    2011-03-15

    Emission from a molecular light source depends on its optical and chemical environment. This dependence is different for various sources. We present a general classification in terms of constant-amplitude and constant-power sources. Using this classification, we have described the response to both changes in the local density of states and stimulated emission. The unforeseen consequences of this classification are illustrated for photonic studies by random laser experiments and are in good agreement with our correspondingly developed theory. Our results require a revision of studies on sources in complex media.

  16. The impact of light source spectral power distribution on sky glow

    NASA Astrophysics Data System (ADS)

    Luginbuhl, Christian B.; Boley, Paul A.; Davis, Donald R.

    2014-05-01

    The effect of light source spectral power distribution on the visual brightness of anthropogenic sky glow is described. Under visual adaptation levels relevant to observing the night sky, namely with dark-adapted (scotopic) vision, blue-rich (“white”) sources produce a dramatically greater sky brightness than yellow-rich sources. High correlated color temperature LEDs and metal halide sources produce a visual brightness up to 8× brighter than low-pressure sodium and 3× brighter than high-pressure sodium when matched lumen-for-lumen and observed nearby. Though the sky brightness arising from blue-rich sources decreases more strongly with distance, the visual sky glow resulting from such sources remains significantly brighter than from yellow sources out to the limits of this study at 300 km.

  17. Device characterization of the VCSEL-on-silicon as an on chip light source

    NASA Astrophysics Data System (ADS)

    Kwack, Myung-Joon; Jang, Ki-Seok; Joo, Jiho; Park, Hyundai; Oh, Jin Hyuk; Park, Jaegyu; Kim, Sanggi; Kim, Gyungock

    2016-03-01

    Advancement of silicon photonics technology can offer a new dimension in data communications with un-precedent bandwidth. Increasing the integration level in the silicon photonics is required to develop compact high-performance chip-level optical interconnects for future systems. Especially, monolithic integration of light source on a silicon wafer is important for future silicon photonic integrated circuits, since realizing a compact on-chip light source on a silicon wafer is a serious issue which impedes practical implementation of the silicon photonic interconnects. At present, due to the lack of a practical light source based on Group IV elements, flip chip-bonded or packaged lasers based on III-V semiconductor are usually being used as external light sources, to feed silicon modulators on SOI wafers to complete a photonic transmitter, except the reported silicon hybrid lasers monolithic-integrated on SOI wafers. To overcome above problem, we have proposed a compact on-chip light source, the directly monolithic-integrated VCSEL on a bulk silicon wafer (VCSEL-on-Si), based on the transplanted epitaxial film by substrate lift-off process and following device-fabrication on the bulk Si wafer. This can offer practical low-power-consumption light sources integrated on a silicon wafer, which can provide a complete chip-level I/O set when combined with monolithic-integrated vertical-illumination Ge-on-Si photodetectors on the same silicon wafer. In this work, we report the characterization of direct-modulation VCSELs-on-Si for λ ~850 nm with CW optical output power > ~2 mW and the threshold current < ~3 mA, over 10 Gb/s operations. We also discuss about the thermal characteristics of the VCSELs-on-Si.

  18. An intense, high-repetition nanosecond light source using a commercially available Xe-arc lamp

    NASA Astrophysics Data System (ADS)

    Araki, Tsutomu; Yamada, Akihisa; Uchida, Teruo

    1993-07-01

    We describe the construction and emission characteristics of a Xe light source that produces broadband emission spectrum (250-650 nm) and high-repetition pulsed light of nanosecond duration. The standard dc-operated Xe-arc lamp, which is commercially available, is employed as the primary light source, with modified circuitry to realize pulsed operation. A dc voltage higher than 5 kV is applied to the electrode gap through a high-value resistor in order to generate a periodical discharge of current between the electrode gap. In order to further increase the intensity of the light pulses, the electrical polarity of the electrode must be in inverse connection relative to the normal connection under the dc operation. Intense light pulses as large as 20 W (peak value) of 3 ns width were generated repetitively from the Xe lamp. Fluorescence lifetimes of a quinine-sulfate solution and a fluorescent cell nucleus were measured to demonstrate the usefulness of the light source.

  19. A novel method for detecting light source for digital images forensic

    NASA Astrophysics Data System (ADS)

    Roy, A. K.; Mitra, S. K.; Agrawal, R.

    2011-06-01

    Manipulation in image has been in practice since centuries. These manipulated images are intended to alter facts — facts of ethics, morality, politics, sex, celebrity or chaos. Image forensic science is used to detect these manipulations in a digital image. There are several standard ways to analyze an image for manipulation. Each one has some limitation. Also very rarely any method tried to capitalize on the way image was taken by the camera. We propose a new method that is based on light and its shade as light and shade are the fundamental input resources that may carry all the information of the image. The proposed method measures the direction of light source and uses the light based technique for identification of any intentional partial manipulation in the said digital image. The method is tested for known manipulated images to correctly identify the light sources. The light source of an image is measured in terms of angle. The experimental results show the robustness of the methodology.

  20. Long-term storage life of light source modules by temperature cycling accelerated life test

    NASA Astrophysics Data System (ADS)

    Ningning, Sun; Manqing, Tan; Ping, Li; Jian, Jiao; Xiaofeng, Guo; Wentao, Guo

    2014-05-01

    Light source modules are the most crucial and fragile devices that affect the life and reliability of the interferometric fiber optic gyroscope (IFOG). While the light emitting chips were stable in most cases, the module packaging proved to be less satisfactory. In long-term storage or the working environment, the ambient temperature changes constantly and thus the packaging and coupling performance of light source modules are more likely to degrade slowly due to different materials with different coefficients of thermal expansion in the bonding interface. A constant temperature accelerated life test cannot evaluate the impact of temperature variation on the performance of a module package, so the temperature cycling accelerated life test was studied. The main failure mechanism affecting light source modules is package failure due to solder fatigue failure including a fiber coupling shift, loss of cooling efficiency and thermal resistor degradation, so the Norris-Landzberg model was used to model solder fatigue life and determine the activation energy related to solder fatigue failure mechanism. By analyzing the test data, activation energy was determined and then the mean life of light source modules in different storage environments with a continuously changing temperature was simulated, which has provided direct reference data for the storage life prediction of IFOG.

  1. The average cosine due to an isotropic light source in the ocean

    NASA Astrophysics Data System (ADS)

    Maffione, R. A.; Jaffe, J. S.

    1995-07-01

    The average cosine ? of the light field created by an isotropic point source (IPS) embedded in a homogeneous ocean is investigated with a Monte Carlo model. Two volume scattering functions (VSFs) are used in the model, taken from Petzold (1972), to compute the radiance distributions at various distances from the source. The simulated radiance distributions are compared with measurements of the point spread function made at Lake Pend Oreille, Idaho, during the 1992 optical closure experiment. An analytic model is presented for ? which is valid to at least 15 optical lengths from the source. The model shows that the mean light path, derived from ?, is a strong function of the single scattering albedo and the VSF. We found that errors in estimating the absorption coefficient by neglecting the increase in the mean light path, which is due to scattering, vary between 5% and 12% for nearly all natural waters. A mathematical proof is given that ? as the distance to the IPS goes to zero. An analytic expression is derived for ? close to a finite diffuse-isotropic source which shows that ? approaches one as the distance decreases, but at extremely close distances, ? as the distance to the surface of the source goes to zero. At distances beyond one attenuation length, for finite sources small compared to an attenuation length, ? behaves essentially as it would for a point source. An asymptotic model for ? as a function of the single scattering albedo is given with coefficients that depend on the VSF. Model results and comparisons with measured PSFs reveal the surprising result that the light field from an embedded isotropic point source in the ocean does not exhibit asymptotic behavior as far as 15 attenuation lengths from the source.

  2. Aluminum nitride nanowire light emitting diodes: Breaking the fundamental bottleneck of deep ultraviolet light sources.

    PubMed

    Zhao, S; Connie, A T; Dastjerdi, M H T; Kong, X H; Wang, Q; Djavid, M; Sadaf, S; Liu, X D; Shih, I; Guo, H; Mi, Z

    2015-02-16

    Despite broad interest in aluminum gallium nitride (AlGaN) optoelectronic devices for deep ultraviolet (DUV) applications, the performance of conventional Al(Ga)N planar devices drastically decays when approaching the AlN end, including low internal quantum efficiencies (IQEs) and high device operation voltages. Here we show that these challenges can be addressed by utilizing nitrogen (N) polar Al(Ga)N nanowires grown directly on Si substrate. By carefully tuning the synthesis conditions, a record IQE of 80% can be realized with N-polar AlN nanowires, which is nearly ten times higher compared to high quality planar AlN. The first 210 nm emitting AlN nanowire light emitting diodes (LEDs) were achieved, with a turn on voltage of about 6 V, which is significantly lower than the commonly observed 20 - 40 V. This can be ascribed to both efficient Mg doping by controlling the nanowire growth rate and N-polarity induced internal electrical field that favors hole injection. In the end, high performance N-polar AlGaN nanowire LEDs with emission wavelengths covering the UV-B/C bands were also demonstrated.

  3. Light source with carbon nanotubes field emission cathode and rare-earth doped nanocrystalline phosphors

    NASA Astrophysics Data System (ADS)

    Psuja, P.; Strek, W.

    2007-09-01

    In this work we report a new carbon nanotubes field emission (CNT-FED) light source with nanocrystalline phosphors. The nanocrystalline powders of cerium doped yttrium aluminum garnet were obtained by modified Pechini method. The phosphor has been electrophoretically deposited on ITO-glass substrates. The cathode composed of carbon nanotubes was fabricated in the same manner. A light source was assembled and tested. Low-voltage cathodoluminescent spectra and I-V characteristics of fabricated cathodes were measured. A possibility of application of Ce doped nanocrystalline YAG phosphor in the field emission displays (FEDs) was discussed.

  4. Modular approach to achieving the next-generation X-ray light source

    NASA Astrophysics Data System (ADS)

    Biedron, S. G.; Milton, S. V.; Freund, H. P.

    2001-12-01

    A modular approach to the next-generation light source is described. The "modules" include photocathode, radio-frequency, electron guns and their associated drive-laser systems, linear accelerators, bunch-compression systems, seed laser systems, planar undulators, two-undulator harmonic generation schemes, high-gain harmonic generation systems, nonlinear higher harmonics, and wavelength shifting. These modules will be helpful in distributing the next-generation light source to many more laboratories than the current single-pass, high-gain free-electron laser designs permit, due to both monetary and/or physical space constraints.

  5. Simultaneous optical coherence tomography and autofluorescence microscopy with a single light source

    NASA Astrophysics Data System (ADS)

    Dai, Cuixia; Liu, Xiaojing; Jiao, Shuliang

    2012-08-01

    We have accomplished simultaneous spectral domain optical coherence tomography (SD-OCT) and autofluorescence (AF) microscopy with a broadband light source centered at 415 nm. The light source was provided by frequency-doubling of an ultra-fast broadband Ti:Sapphire laser. With a bandwidth of 8 nm, the visible SD-OCT achieved a depth resolution of ˜12 μm. Since the two imaging modalities are provided by the same group of photons, their images are intrinsically registered. The dual-modal system is capable of providing OCT imaging and molecular contrasts simultaneously. The imaging system was tested on imaging biological samples ex vivo and in vivo.

  6. Ultrahigh-Resolution Optical Coherence Tomography with LED-Phosphor-Based Broadband Light Source

    NASA Astrophysics Data System (ADS)

    Tsai, Meng-Tsan; Hung, Jeng-Jie; Chan, Ming-Che

    2013-12-01

    This study proposed and demonstrated the potential use of LED phosphors as a simple light source for ultrahigh-resolution spectral-domain optical coherence tomography (SD-OCT) in the visible regime. Excited by a 405 nm diode laser, broadband spontaneous emission from three different LED phosphors was generated. The best axial resolution was 1.7 µm in air, and finally, corresponding three-dimensional (3D) ultrahigh-resolution SD-OCT imaging was performed with the proposed broadband light source.

  7. High-resolution VUV spectroscopy: New results from the Advanced Light Source

    SciTech Connect

    Schlachter, F.; Bozek, J.

    1996-06-01

    Third-generation synchrotron light sources are providing photon beams of unprecedented brightness for researchers in atomic and molecular physics. Beamline 9.0.1, an undulator beamline at the Advanced Light Source (ALS), produces a beam in the vacuum-ultraviolet (VUV) region of the spectrum with exceptional flux and spectral resolution. Exciting new results from experiments in atomic and molecular VUV spectroscopy of doubly excited autoionizing states of helium, hollow lithium, and photoelectron spectroscopy of small molecules using Beamline 9.0.1 at the ALS are reported.

  8. Panorama of new generation of accelerator based short wavelength coherent light sources

    NASA Astrophysics Data System (ADS)

    Couprie, M. E.

    2015-12-01

    The newly developed intense short wavelength light sources (from Extreme Ultra-Violet (EUV) to X-rays) have open the path to the exploration of matter for revealing structures and electronic processes and for following their evolution in time. After drawing the panorama of existing accelerator based short wavelength light sources, the new trends of evolution of short wavelengths FEL are described, with some illustrations with the example of the LUNEX5 (free electron Laser a New accelerator for the Exploitation of X-ray radiation of 5th generation) demonstrator project of advanced compact Free Electron Laser.

  9. Synthesis of labeled compounds using recovered tritium from expired beta light sources

    SciTech Connect

    Matei, L.; Postolache, C.; Bubueanu, G.; Podina, C.

    2008-07-15

    In this paper, the technological procedures for extracting tritium from beta light source are highlighted. The recovered tritium was used in the synthesis of organically labeled compounds and in the preparation of tritiated water (HTO) with high specific activity. Technological procedures for treatment of beta light sources consist of: envelope breaking into evacuated enclosure, the radioactive gaseous mixture pumping and its storage on metallic sodium. The mixtures of T{sub 2} and {sup 3}He were used in the synthesis of tritium labeled steroid hormones, nucleosides analogues and for the preparation of HTO with high radioactivity concentrations. (authors)

  10. Symposium on biological effects and measurement of light sources. [Lead abstract

    SciTech Connect

    Not Available

    1981-02-01

    These proceedings summarize the current effort of the Bureau of Radiological Health in the area of light research. The results of research being conducted on the biological effects and measurement of light sources are presented. Session topics include: measurement and electronic device activities; research and regulations; phototherapy; ocular effects; and biochemical and cellular systems. Twenty abstracts of individual papers have been prepared for inclusion in the Energy Data Base. There are 11 papers not within the scope of the Energy Data Base. These papers are in the areas of noncoherent optical radiation measurements, phototherapy, and ocular effects of light. (RJC)

  11. [Hygienic aspects of the use of LED light sources for general illumination in schools].

    PubMed

    Kuchma, V R; Sukhareva, L M; Teksheva, L M; Stepanova, M I; Sazaniuk, Z I

    2013-01-01

    For the time present becoming more common semiconductor sources of artificial lighting has become a more and more frequent practice. With the aim to study the impact of LEDs on the health of schoolchildren studies in experimental conditions (specially equipped classrooms) were performed. The comparative analysis of the state of vision, mental health and emotional state of pupils in primary, middle and high schools under fluorescent and LED lighting, meeting to the regulatory requirements, has revealed that the physiological cost of schooling in the use of LED units in classrooms is lower than in a traditional, fluorescent lighting. PMID:24340905

  12. Transdental photo-activation technique: hardness and marginal adaptation of composite restorations using different light sources.

    PubMed

    Alves, Eliane Bemerguy; Alonso, Roberta Caroline Bruschi; Correr, Gisele Maria; Correr, Américo Bortolazzo; de Moraes, Rafael Ratto; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço

    2008-01-01

    This study investigated the influence of different light sources associated with a transdental photoactivation technique on the marginal adaptation and hardness of composite restorations. Cavities (3 mm wide x 3 mm long x 1.5 mm in deep) were prepared on flattened bovine dentin and filled with Z250 composite (3M ESPE). Nine groups (n=10) were defined according to the curing technique (direct; transdental--photo-activation through 1 mm of enamel and 2 mm of dentin; mixed--transdental + direct) and light source (QTH XL2500, 3M ESPE; PAC Apollo 95E, DMD; LED Ultrablue Is, DMC) combination. Marginal adaptation was evaluated using a dye staining method, and the percentage of stained margins was recorded. Knoop Hardness readings were made across the transversal section of the fillings. Data were submitted to two-way ANOVA and Tukey's test (p< or =0.05). For margin analysis, although none of the curing conditions provided perfect adaptation, the mixed technique showed lower gap formation. No significant differences were detected between the transdental and other techniques, and no significant differences were detected among the light sources. For hardness, the direct technique showed slightly greater hardness than the mixed technique. Also, the mixed technique yielded greater hardness than the transdental technique. Among the light sources, the LED showed greater hardness than the PAC; whereas, no significant differences between the QTH and other sources were detected. The mixed technique might improve the marginal adaptation of restorations, while not being detrimental to composite hardness.

  13. Seasonal variations in light scattering in the New York region and their relation to sources

    SciTech Connect

    Leaderer, B.P.; Tanner, R.L.; Lioy, P.J.; Stolwijk, J.A.J.

    1980-01-01

    Light scattering data collected during two periods of intensive sampling in New York City (one during summer months and one during winter months) are discussed and analyzed for diurnal patterns, their relationship to pollutant emission sources, meteorological parameters, and the size distribution and chemical composition of the ambient aerosol. The lack of a diurnal pattern for light scattering in summer in combination with a strong positive association with ozone and wind direction dependency suggests that in summer the transport of an aged aerosol in photochemically rich air masses rather than local emissions of primary pollutants is largely responsible for the observed levels of light scattering in New York City. Winter levels of light scattering observed in New York City, while approximately 50% lower than summer levels, were much less dependent on wind direction and closely related to pollutant emissions from local sources. This suggests that locally generated aerosol dominates light scattering in the winter. Particles 0.1..mu..m to 1.3..mu..m in diameter were strongly correlated with light scattering in New York City during both summer and winter periods. However, a given volume of aerosol between 0.1..mu..m and 1.3..mu..m scattered more light in summer than in winter, indicating the fresher nature of the winter aerosol. Variance in dry particulate light scattering was found to principally account for light extinction variance (calculated from airport visibility observations) in summer and winter. Sulfate aerosol was strongly correlated with light scattering during both summer and winter periods.

  14. INFLUENCE OF LIGHT CURING SOURCE ON MICROHARDNESS OF COMPOSITE RESINS OF DIFFERENT SHADES

    PubMed Central

    BRISO, André Luiz Fraga; FEDEL, Tânia Maria; PEREIRA, Sibéria de Morais; MAURO, Sílvio José; SUNDFELD, Renato Herman; SUNDEFELD, Maria Lúcia Marçal Mazza

    2006-01-01

    Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units. Purpose: This study evaluated the microhardness of 4 shades (B-0.5, B-1, B-2 and B-3) of composite resin Filtek Z-250 (3M ESPE) after light curing with 4 light sources, being one halogen (Ultralux – Dabi Atlante) and three LED (Ultraled – Dabi Atlante, Ultrablue – DMC and Elipar Freelight – 3M ESPE). Methods: 192 specimens were distributed into 16 groups, and materials were inserted in a single increment in cylindrical templates measuring 4mm x 4mm and light cured as recommended by the manufacturer. Then, they were submitted to microhardness test on the top and bottom aspects of the cylinders. Results: The hardness values achieved were submitted to analysis of variance and to Tukey test at 5% confidence level. It was observed that microhardness of specimens varied according to the shade of the material and light sources employed. The LED appliance emitting greater light intensity provided the highest hardness values with shade B-0.5, allowing the best curing. On the other hand, appliances with low light intensity were the least effective. It was also observed that the bottom of specimens was more sensitive to changes in shade. Conclusion: Light intensity of LED light curing units is fundamental for their good functioning, especially when applied in resins with darker shades. PMID:19089023

  15. Solar neutrinos and the influences of opacity, thermal instability, additional neutrino sources, and a central black hole on solar models

    NASA Technical Reports Server (NTRS)

    Stothers, R. B.; Ezer, D.

    1972-01-01

    Significant quantities that affect the internal structure of the sun are examined for factors that reduce the temperature near the sun's center. The four factors discussed are: opacity, central black hole, thermal instability, and additional neutrino sources.

  16. IR and THz Beamlines at the Metrology Light Source of the PTB

    NASA Astrophysics Data System (ADS)

    Müller, Ralph; Hoehl, Arne; Klein, Roman; Serdyukov, Anton; Ulm, Gerhard; Feikes, Jörg; von Hartrott, Michael; Schade, Ulrich; Wüstefeld, Godehard

    2010-02-01

    The low-energy electron storage ring Metrology Light Source (MLS), a dedicated synchrotron radiation source, is in user operation since April 2008. As a special option it provides coherent synchrotron radiation (CSR) in the THz range when it is operated in a low-α mode with short electron bunches. At the MLS three beamlines dedicated to the use of IR and THz radiation were designed, built and commissioned.

  17. The tools of PDT: light sources and devices. Can they help in getting better therapeutic results?

    NASA Astrophysics Data System (ADS)

    Boucher, Didier

    2011-08-01

    PDT is a drug and device therapy using photosensitizing drugs activated by laser light, for tissue ablation. PDT light sources must deliver wavelengths matching the absorption of photosensitizers' compound without any side thermal effect. According to applications, these sources need to be: - pled to relatively small optical fibres so as to bring the light energy, of specific wavelength, inside of the body (gastroenterology, head & neck, urology, pneumology), - coupled to a slit lamp adapter to transmit the light to the eye (AMD) - or allow a direct illumination of tissues when large areas must be treated (dermatology). But they also need to be user-friendly with limited investment and installation costs. So as to achieve the required effects, several light sources are available and will be used but practical and economical reasons have limited the number and types of these sources. For PDT oncology applications, besides dermatology, it has also been necessary to develop specific light delivery systems based on optical fibres. These devices allow the treatment: - of circular lumens such as oesophagus, bile ducts, lungs - of solid volumes such as prostate, pancreas - of surfaces such as in head and neck - of empty volumes such as bladder, uterus, cervix. Due to the variety of these treatments, a full family of sources has been developed from original sophisticated costly lasers to more recent easy-to-use diode laser systems. The aim of this presentation is to present the actual state of the art of actual available PDT tools, analyze their qualities and weaknesses, analyze the consequences of a good and/or bad choice or good and/or bad utilization on the quality of the therapeutic results and resulting side effects. It will also evaluate the short and medium term developments of new tools and their effect on the development of the therapy including economical aspects.

  18. Energy efficiency and color quality limits in artificial light sources emulating natural illumination.

    PubMed

    Hertog, Wim; Llenas, Aleix; Quintero, Jesús M; Hunt, Charles E; Carreras, Josep

    2014-12-15

    We present in this work a calculation of the theoretical limits attainable for natural light emulation with regard to the joint optimization of the Luminous Efficacy of Radiation and color fidelity by using multiple reflectance spectra datasets, along with an implementation of a physical device that approaches these limits. A reduced visible spectrum of blackbody radiators is introduced and demonstrated which allows lamps designed to emulate natural light to operate with excellent color fidelity and higher efficiency as compared to full visible spectrum sources. It is shown that even though 3,000K and 5,500K blackbody sources have maximum efficacies of 21 lm/W and 89 lm/W, respectively, reduced-spectrum artificial light sources can exceed those values up to 363 lm/W and 313 lm/W, respectively, while retaining excellent color fidelity. Experimental demonstration approaching these values is accomplished through the design and implementation of a 12-channel light engine which emits arbitrarily-tunable spectra. The color fidelity of the designed spectra is assessed through Color Rendering Maps, showing that color fidelity is preserved uniformly over a large spectral reflectance dataset, unlike other approaches to generate white light.

  19. Design of reflector contours to satisfy photometric criteria using physically realizable light sources

    NASA Astrophysics Data System (ADS)

    Spencer, Domina E.

    2001-11-01

    Traditionally reflector design has been confined to the use of surfaces defined in terms of conic sections, assuming that all light sources can be considered to be point sources. In the middle of the twentieth century, it was recognized that major improvements could be made if the shape of the reflector was designed to produce a desired distribution of light form an actual light source. Cylindrical reflectors were created which illuminated airport runways using fluorescent lamps in such a way that pilots could make visual landings safely even in fog. These reflector contours were called macrofocal parabolic cylinders. Other new reflector contours introduced were macrofocal elliptic cylinders which confined the light to long rectangles. Surfaces of revolution the fourth degree were also developed which made possible uniform floodlighting of a circular region. These were called horned and peaked quartics. The optimum solution of the automotive head lighting problem has not yet been found. The paper concludes with a discussion of the possibility of developing reflectors which are neither cylindrical nor rotational but will produce the optimum field of view for the automobile driver both in clear weather and in fog.

  20. Operation of general purpose stepping motor controllers at the National Synchrotron Light Source

    SciTech Connect

    Stubblefield, F.W.

    1986-10-01

    A prototype and four copies of a general purpose subsystem for mechanical positioning of detectors, samples, and beam line optical elements which constitute experiments at the National Synchrotron Light Source facility of Brookhaven National Laboratory have been constructed and placed into operation. Construction of a sixth subsystem is nearing completion. The subsystems effect mechanical positioning by controlling a set of stepping motors and their associated position encoders. The units are general purpose in the sense that they receive commands over a standard 9600 baud asynchronous serial line compatible with the RS-232-C electrical signal standard, generate TTL-compatible streams of stepping pulses which can be used with a wide variety of stepping motors, and read back position values from a number of different types and models of position encoder. The basic structure of the motor controller subsystem will be briefly reviewed. Short descriptions of the positioning apparatus actuated at each of the test and experiment stations employing a motor control unit are given. Additions and enhancements to the subsystem made in response to problems indicated by actual operation of the four installed units are described in more detail.