Science.gov

Sample records for additional quality control

  1. Quality control of laser- and powder bed-based Additive Manufacturing (AM) technologies

    NASA Astrophysics Data System (ADS)

    Berumen, Sebastian; Bechmann, Florian; Lindner, Stefan; Kruth, Jean-Pierre; Craeghs, Tom

    The quality of metal components manufactured by laser- and powder bed-based additive manufacturing technologies has continuously been improved over the last years. However, to establish this production technology in industries with very high quality standards the accessibility of prevalent quality management methods to all steps of the process chain needs still to be enhanced. This publication describes which tools are and will be available to fulfil those requirements from the perspective of a laser machine manufacturer. Generally five aspects of the part building process are covered by separate Quality Management (QM) modules: the powder quality, the temperature management, the process gas atmosphere, the melt pool behaviour and the documentation module. This paper sets the focus on melt pool analysis and control.

  2. Carbamate deposit control additives

    SciTech Connect

    Honnen, L.R.; Lewis, R.A.

    1980-11-25

    Deposit control additives for internal combustion engines are provided which maintain cleanliness of intake systems without contributing to combustion chamber deposits. The additives are poly(oxyalkylene) carbamates comprising a hydrocarbyloxyterminated poly(Oxyalkylene) chain of 2-5 carbon oxyalkylene units bonded through an oxycarbonyl group to a nitrogen atom of ethylenediamine.

  3. Additional Saturday rehabilitation improves functional independence and quality of life and reduces length of stay: a randomized controlled trial

    PubMed Central

    2013-01-01

    Background Many inpatients receive little or no rehabilitation on weekends. Our aim was to determine what effect providing additional Saturday rehabilitation during inpatient rehabilitation had on functional independence, quality of life and length of stay compared to 5 days per week of rehabilitation. Methods This was a multicenter, single-blind (assessors) randomized controlled trial with concealed allocation and 12-month follow-up conducted in two publically funded metropolitan inpatient rehabilitation facilities in Melbourne, Australia. Patients were eligible if they were adults (aged ≥18 years) admitted for rehabilitation for any orthopedic, neurological or other disabling conditions excluding those admitted for slow stream rehabilitation/geriatric evaluation and management. Participants were randomly allocated to usual care Monday to Friday rehabilitation (control) or to Monday to Saturday rehabilitation (intervention). The additional Saturday rehabilitation comprised physiotherapy and occupational therapy. The primary outcomes were functional independence (functional independence measure (FIM); measured on an 18 to 126 point scale), health-related quality of life (EQ-5D utility index; measured on a 0 to 1 scale, and EQ-5D visual analog scale; measured on a 0 to 100 scale), and patient length of stay. Outcome measures were assessed on admission, discharge (primary endpoint), and at 6 and 12 months post discharge. Results We randomly assigned 996 adults (mean (SD) age 74 (13) years) to Monday to Saturday rehabilitation (n = 496) or usual care Monday to Friday rehabilitation (n = 500). Relative to admission scores, intervention group participants had higher functional independence (mean difference (MD) 2.3, 95% confidence interval (CI) 0.5 to 4.1, P = 0.01) and health-related quality of life (MD 0.04, 95% CI 0.01 to 0.07, P = 0.009) on discharge and may have had a shorter length of stay by 2 days (95% CI 0 to 4, P = 0.1) when compared to

  4. Smog control fuel additives

    SciTech Connect

    Lundby, W.

    1993-06-29

    A method is described of controlling, reducing or eliminating, ozone and related smog resulting from photochemical reactions between ozone and automotive or industrial gases comprising the addition of iodine or compounds of iodine to hydrocarbon-base fuels prior to or during combustion in an amount of about 1 part iodine per 240 to 10,000,000 parts fuel, by weight, to be accomplished by: (a) the addition of these inhibitors during or after the refining or manufacturing process of liquid fuels; (b) the production of these inhibitors for addition into fuel tanks, such as automotive or industrial tanks; or (c) the addition of these inhibitors into combustion chambers of equipment utilizing solid fuels for the purpose of reducing ozone.

  5. Quality control review: implementing a scientifically based quality control system.

    PubMed

    Westgard, James O; Westgard, Sten A

    2016-01-01

    This review focuses on statistical quality control in the context of a quality management system. It describes the use of a 'Sigma-metric' for validating the performance of a new examination procedure, developing a total quality control strategy, selecting a statistical quality control procedure and monitoring ongoing quality on the sigma scale. Acceptable method performance is a prerequisite to the design and implementation of statistical quality control procedures. Statistical quality control can only monitor performance, and when properly designed, alert analysts to the presence of additional errors that occur because of unstable performance. A new statistical quality control planning tool, called 'Westgard Sigma Rules,' provides a simple and quick way for selecting control rules and the number of control measurements needed to detect medically important errors. The concept of a quality control plan is described, along with alternative adaptations of a total quality control plan and a risk-based individualized quality control plan. Finally, the ongoing monitoring of analytic performance and test quality are discussed, including determination of measurement uncertainty from statistical quality control data collected under intermediate precision conditions and bias determined from proficiency testing/external quality assessment surveys. A new graphical tool, called the Sigma Quality Assessment Chart, is recommended for demonstrating the quality of current examination procedures on the sigma scale. PMID:26150675

  6. Heat treatment and the use of additives to improve the stability of paralytic shellfish poisoning toxins in shellfish tissue reference materials for internal quality control and proficiency testing.

    PubMed

    Burrell, Stephen; Clion, Valentin; Auroy, Virginie; Foley, Barry; Turner, Andrew D

    2015-06-01

    The need for homogenous reference materials stable for paralytic shellfish toxins is vital for the monitoring and quality assurance of these potent neurotoxins in shellfish. Two stabilisation techniques were investigated, heat treatment through autoclaving and the addition of preserving additives into the tissue matrix. Short and long-term stability experiments as well as homogeneity determination were conducted on materials prepared by both techniques in comparison with an untreated control using two LC-FLD methods. Both techniques improved the stability of the matrix and the PSP toxins present compared to the controls. A material was prepared using the combined techniques of heat treatment followed by spiking with additives and data is presented from this optimised reference material as used over a two year period in the Irish national monitoring program and in a development exercise as part of a proficiency testing scheme operated by QUASIMEME (Quality Assurance of Information for Marine Environmental Monitoring in Europe) since 2011. The results were indicative of the long-term stability of the material as evidenced through consistent assigned values in the case of the proficiency testing scheme and a low relative standard deviation of 10.5% for total toxicity data generated over 24 months. PMID:25816999

  7. [Hospital pharmacist has a rule for best practice use and French hospital activity tariffs. Example of a pharmaceutical quality control for drugs reimbursed in addition of DRGs].

    PubMed

    Hedoux, S; Dode, X; Pivot, C; Couray-Targe, S; Aulagner, G

    2012-07-01

    The best practice contract has given a new objective to the hospital pharmacists for the reimbursement in addition to Diagnosis Related Groups' (DRGs) tariffs. We built our pharmaceutical quality control for the administration traceability follow-up regarding the DRGs and the cost of care, for two reasons: the nominal drugs dispensation in link with the prescription made by pharmacist and the important expenditure of these drugs. Our organization depends on the development level of the informatized drugs circuit and minimizes the risk of financial shortfalls or wrong benefits, possible causes of economic penalties for our hospital. On the basis of this follow-up, we highlighted our activity and identified problems of management and drugs circuit organization. The quality of the administration traceability impacts directly on the quality of the medical records and the reimbursements of the expensive drugs. A better knowledge of prescription software is also required for a better quality and security of the medical data used in the medical informatic systems. The drugs management and the personal treatment in and between the care units need to be improved too. We have to continue and improve our organization with the future financial model for ATU drugs and the FIDES project. The health personnel awareness and the development of best informatic tools are also required. PMID:22818260

  8. Quality Leadership and Quality Control

    PubMed Central

    Badrick, Tony

    2003-01-01

    Different quality control rules detect different analytical errors with varying levels of efficiency depending on the type of error present, its prevalence and the number of observations. The efficiency of a rule can be gauged by inspection of a power function graph. Control rules are only part of a process and not an end in itself; just as important are the trouble-shooting systems employed when a failure occurs. 'Average of patient normals' may develop as a usual adjunct to conventional quality control serum based programmes. Acceptable error can be based on various criteria; biological variation is probably the most sensible. Once determined, acceptable error can be used as limits in quality control rule systems. A key aspect of an organisation is leadership, which links the various components of the quality system. Leadership is difficult to characterise but its key aspects include trust, setting an example, developing staff and critically setting the vision for the organisation. Organisations also have internal characteristics such as the degree of formalisation, centralisation, and complexity. Medical organisations can have internal tensions because of the dichotomy between the bureaucratic and the shadow medical structures. PMID:18568046

  9. QUALITY CONTROLS FOR PCR

    EPA Science Inventory

    The purpose of this presentation is to present an overview of the quality control (QC) sections of a draft EPA document entitled, "Quality Assurance/Quality Control Guidance for Laboratories Performing PCR Analyses on Environmental Samples." This document has been prepared by th...

  10. [Quality control dose calibrators].

    PubMed

    Montoza Aguado, M; Delgado García, A; Ramírez Navarro, A; Salgado García, C; Muros de Fuentes, M A; Ortega Lozano, S; Bellón Guardia, M E; Llamas Elvira, J M

    2004-01-01

    We have reviewed the legislation about the quality control of dose calibrator. The importance of verifying the correct work of these instruments, is fundamental in daily practice of radiopharmacy and nuclear medicine. The Spanish legislation establishes to include these controls as part of the quality control of radiopharmaceuticals, and the program of quality assurance in nuclear medicine. We have reviewed guides and protocols from international eminent organizations, summarizing the recommended tests and periodicity of them. PMID:15625064

  11. Financial Quality Control of In-Patient Chemotherapy in Germany: Are Additional Payments Cost-Covering for Pharmaco-Oncological Expenses?

    PubMed Central

    Jacobs, Volker R.; Mallmann, Peter

    2011-01-01

    Summary Background Cost-covering in-patient care is increasingly important for hospital providers in Germany, especially with regard to expensive oncological pharmaceuticals. Additional payments (Zusatzentgelte; ZE) on top of flat rate diagnose-related group (DRG) reimbursement can be claimed by hospitals for in-patient use of selected medications. To verify cost coverage of in-patient chemotherapies, the costs of medication were compared to their revenues. Method From January to June 2010, a retrospective cost-revenue study was performed at a German obstetrics/gynecology university clinic. The hospital's pharmacy list of inpatient oncological therapies for breast and gynecological cancer was checked for accuracy and compared with the documented ZEs and the costs and revenues for each oncological application. Results N = 45 in-patient oncological therapies were identified in n = 18 patients, as well as n = 7 bisphosphonate applications; n = 11 ZEs were documented. Costs for oncological medication were € 33,752. The corresponding ZE revenues amounted to only € 13,980, resulting in a loss of € 19,772. All in-patient oncological therapies performed were not cost-covering. Data discrepancy, incorrect documentation and cost attribution, and process aborts were identified. Conclusions Routine financial quality control at the medicine-pharmacy administration interface is implemented, with monthly comparison of costs and revenues, as well as admission status. Non-cost-covering therapies for in-patients should be converted to out-patient therapies. Necessary adjustments of clinic processes are made according to these results, to avoid future losses. PMID:21673822

  12. Radiographic quality control devices.

    PubMed

    2000-04-01

    In this study, we evaluate eight radiographic quality control (QC) devices, which noninvasively measure the output from a variety of diagnostic x-ray production systems. When used as part of a quality assurance (QA) program, radiographic QC devices help ensure that x-ray equipment is working within acceptable limits. This in turn helps ensure that high-quality images are achieved with appropriate radiation doses and that resources are used efficiently (for example, by minimizing the number of repeat exposures required). Our testing focused on the physical performance, ease of use, and service and maintenance characteristics that affect the use of these devices for periodic, routine measurements of x-ray system parameters. We found that all the evaluated models satisfactorily measure all the parameters normally needed for a QA program. However, we did identify a number of differences among the models--particularly in the range of exposure levels that can be effectively measured and the ease of use. Three models perform well for a variety of applications and are very easy to use; we rate them Preferred. Three additional models have minor limitations but otherwise perform well; we rate them Acceptable. We recommend against purchasing two models because, although each performs acceptably for most applications, neither model can measure low levels of radiation. This Evaluation covers devices designed to measure the output of x-ray tubes noninvasively. These devices, called radiographic quality control (QC) devices, or QC meters, are typically used by medical physicists, x-ray engineers, biomedical engineers, and suitably trained radiographic technologists to make QC measurements. We focus on the use of these devices as part of an overall quality assurance (QA) program. We have not evaluated their use for other applications, such as acceptance testing. To be included in this study, a device must be able to measure the exposure- and kVp-related characteristics of most x

  13. Addition of PM2.5 into the National Ambient Air Quality Standards of China and the Contribution to Air Pollution Control: The Case Study of Wuhan, China

    PubMed Central

    You, Mingqing

    2014-01-01

    PM2.5 has gradually become a major environmental problem of China with its rapid economic development, urbanization, and increasing of motor vehicles. Findings and awareness of serious PM2.5 pollution make the PM2.5 a new criterion pollutant of the Chinese National Ambient Air Quality Standard (NAAQS) revised in 2012. The 2012 NAAQS sets the PM2.5 concentrate limitation with the 24-hour average value and the annual mean value. Wuhan is quite typical among central and southern China in climate, economy, development level, and energy consumption. The data are cited from the official website of Wuhan Environmental Protection Bureau and cover the period from 1 January to 30 June 2013. The data definitely confirm the existence of serious PM2.5 pollution in Wuhan and indicate that the addition of PM2.5 as a criterion pollutant significantly brings down the attainment rate of air quality. The example of Wuhan reveals that local governments should take measures to reduce the emission of PM2.5 if it affects the attainment rate and the performance evaluation value of air quality. The main contribution of 2012 NAAQS is that it brings down the attainment rate of the air quality and forces local governmental officials to take the measures accordingly. PMID:24982994

  14. Instrument Quality Control.

    PubMed

    Jayakody, Chatura; Hull-Ryde, Emily A

    2016-01-01

    Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs. PMID:27316990

  15. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Additional quality assessment activities. 460.140... FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional quality assessment activities. A PACE organization must meet external quality assessment and reporting...

  16. Japanese Quality Control Circles.

    ERIC Educational Resources Information Center

    Nishiyama, Kazuo

    In recent years, United States scholars with an interest in international business and organizational communication have begun to notice the success of Japanese "quality control circles." These are small groups, usually composed of seven to ten workers, who are organized at the production levels within most large Japanese factories. A typical…

  17. SIMBAD Quality-Control

    NASA Astrophysics Data System (ADS)

    Lesteven, Soizick

    1993-01-01

    Taking into consideration the amount and the complexity of SIMBAD data, it is necessary to use automatic methods to control and assure the quality of the SIMBAD database. One possibility is to apply multivariate data analysis to the content of documents related to astronomical data. The method and first results are presented.

  18. Vgi Quality Control

    NASA Astrophysics Data System (ADS)

    Fonte, C. C.; Bastin, L.; Foody, G.; Kellenberger, T.; Kerle, N.; Mooney, P.; Olteanu-Raimond, A.-M.; See, L.

    2015-08-01

    This paper presents a framework for considering quality control of volunteered geographic information (VGI). Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  19. SIMBAD quality-control

    NASA Technical Reports Server (NTRS)

    Lesteven, Soizick

    1992-01-01

    bibliographic information in the SIMBAD quality control process. Furthermore, it is possible to connect the physical measurements of stars from SIMBAD to literature concerning these stars from the NASA-STI abstracts. The physical properties of stars (e.g. UBV colors) are not randomly distributed. Stars are distributed among different clusters in a physical parameter space. The authors will show that there are some relations between this classification and the literature concerning these objects clusters in a factor space. They will investigate the nature of the relationship between the SIMBAD measurements and the bibliography. These would be new relationships that are not pre-established by an astronomer. In addition, the bibliography could be neutral information that can be used in combination with the measured parameters.

  20. Fermentation Quality and Additives: A Case of Rice Straw Silage

    PubMed Central

    Oladosu, Yusuff; Magaji, Usman; Hussin, Ghazali; Ramli, Asfaliza; Miah, Gous

    2016-01-01

    Rice cultivation generates large amount of crop residues of which only 20% are utilized for industrial and domestic purposes. In most developing countries especially southeast Asia, rice straw is used as part of feeding ingredients for the ruminants. However, due to its low protein content and high level of lignin and silica, there is limitation to its digestibility and nutritional value. To utilize this crop residue judiciously, there is a need for improvement of its nutritive value to promote its utilization through ensiling. Understanding the fundamental principle of ensiling is a prerequisite for successful silage product. Prominent factors influencing quality of silage product include water soluble carbohydrates, natural microbial population, and harvesting conditions of the forage. Additives are used to control the fermentation processes to enhance nutrient recovery and improve silage stability. This review emphasizes some practical aspects of silage processing and the use of additives for improvement of fermentation quality of rice straw. PMID:27429981

  1. Fermentation Quality and Additives: A Case of Rice Straw Silage.

    PubMed

    Oladosu, Yusuff; Rafii, Mohd Y; Abdullah, Norhani; Magaji, Usman; Hussin, Ghazali; Ramli, Asfaliza; Miah, Gous

    2016-01-01

    Rice cultivation generates large amount of crop residues of which only 20% are utilized for industrial and domestic purposes. In most developing countries especially southeast Asia, rice straw is used as part of feeding ingredients for the ruminants. However, due to its low protein content and high level of lignin and silica, there is limitation to its digestibility and nutritional value. To utilize this crop residue judiciously, there is a need for improvement of its nutritive value to promote its utilization through ensiling. Understanding the fundamental principle of ensiling is a prerequisite for successful silage product. Prominent factors influencing quality of silage product include water soluble carbohydrates, natural microbial population, and harvesting conditions of the forage. Additives are used to control the fermentation processes to enhance nutrient recovery and improve silage stability. This review emphasizes some practical aspects of silage processing and the use of additives for improvement of fermentation quality of rice straw. PMID:27429981

  2. Additive Manufacturing: Ensuring Quality for Spacecraft Applications

    NASA Technical Reports Server (NTRS)

    Swanson, Theodore; Stephenson, Timothy

    2014-01-01

    Reliable manufacturing requires that material properties and fabrication processes be well defined in order to insure that the manufactured parts meet specified requirements. While this issue is now relatively straightforward for traditional processes such as subtractive manufacturing and injection molding, this capability is still evolving for AM products. Hence, one of the principal challenges within AM is in qualifying and verifying source material properties and process control. This issue is particularly critical for applications in harsh environments and demanding applications, such as spacecraft.

  3. Combined dispersant fluid loss control additives

    SciTech Connect

    Villa, J. L.; Zeiner, R. N.

    1985-12-31

    Water soluble polymer compositions containing polyacrylic acid and copolymer of itaconic acid and acrylamide are useful as combined dispersant and fluid loss control additives for aqueous drilling fluids, particularly fresh water, gypsum and seawater muds. An example is a polymer composition containing about 80% by weight polyacrylic acid and about 20% by weight copolymer of itaconic acid and acrylamide in its ammonium salt form.

  4. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional...

  5. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional...

  6. 42 CFR 460.140 - Additional quality assessment activities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES (CONTINUED) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) PROGRAMS OF ALL-INCLUSIVE CARE FOR THE ELDERLY (PACE) Quality Assessment and Performance Improvement § 460.140 Additional...

  7. General aviation fuel quality control

    NASA Technical Reports Server (NTRS)

    Poitz, H.

    1983-01-01

    Quality control measures for aviation gasoline, and some of the differences between quality control on avgas and mogas are discussed. One thing to keep in mind is that with motor gasoline you can always pull off to the side of the road. It's not so easy to do in an airplane. Consequently, there are reasons for having the tight specifications and the tight quality control measures on avgas as compared to motor gasoline.

  8. Laboratory tests of sludge-control additives

    SciTech Connect

    Tatnall, R.E.

    1996-07-01

    Laboratory {open_quotes}jar{close_quotes} tests compared eleven different fuel oil and diesel fuel sludge-control additives. Factors studied included (1) ability to disperse and prevent buildup of sludge deposits on surfaces, (2) ability to protect steel from corrosion, (3) ability to inhibit growth and proliferation of bacteria, and (4) ability to disperse water. Results varied greatly, and it was found that many commercial products do not do what they claim. It is concluded that fuel retailers should not believe manufacturers` claims for their additive products, but rather should test such products themselves to be sure that the benefits of treatment are real. A simplified form of the procedure used here is proposed as one way for dealers to do such testing.

  9. Quality control on the frontier

    PubMed Central

    Paszkiewicz, Konrad H.; Farbos, Audrey; O'Neill, Paul; Moore, Karen

    2014-01-01

    In the world of high-throughput sequencing there are numerous challenges to effective data quality control. There are no single quality metrics which are appropriate in all conditions. Here we detail the different open source software used at the Exeter Sequencing Service to provide generic quality control information, as well as more specific metrics for genomic and transcriptomic libraries run on Illumina platforms. PMID:24904650

  10. Monitoring system for the quality assessment in additive manufacturing

    NASA Astrophysics Data System (ADS)

    Carl, Volker

    2015-03-01

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality

  11. Monitoring system for the quality assessment in additive manufacturing

    SciTech Connect

    Carl, Volker

    2015-03-31

    Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality

  12. Quality assurance/quality control manual; National Water Quality Laboratory

    USGS Publications Warehouse

    Pritt, J.W.; Raese, J.W.

    1995-01-01

    Quality-control practices are established for the operation of the U.S. Geological Survey's National Water Quality Laboratory. These practices specify how samples are preserved, shipped, and analyzed in the Laboratory. This manual documents the practices that are currently (1995) used in the Laboratory.

  13. 10 CFR 26.167 - Quality assurance and quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.167 Section 26... Department of Health and Human Services § 26.167 Quality assurance and quality control. (a) Quality assurance program. Each HHS-certified laboratory shall have a quality assurance program that encompasses all...

  14. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.137 Section 26....137 Quality assurance and quality control. (a) Quality assurance program. Each licensee testing facility shall have a quality assurance program that encompasses all aspects of the testing...

  15. Essential elements of quality control.

    PubMed

    Boylan, J C

    1983-11-01

    The components of quality control in the pharmaceutical industry are discussed as they apply to hospital pharmacy admixture services. The pharmaceutical industry complies with the FDA's Current Good Manufacturing Practices, which require manufacturers to have written procedures for ensuring sterility and nonpyrogenicity of injectable products. Because FDA specifies only what outcome measures must be assessed (rather than specific means of assessment), pharmaceutical companies have developed a multiplicity of quality-control systems. However, each system consists of a master formula (quantitative listing of all ingredients), master manufacturing instructions (the recipe for each product), master packaging instructions, and batch records. Documents used by quality control personnel include the specifications (identification, tests, and limits for products), test methods, and sampling procedures. Hospitals should have similar quality-control programs. These programs should systematically prevent or identify and correct deficiencies, measure overall quality, and provide information for managers. Hospital pharmacists whose departments do not have comprehensive programs should consult colleagues who have developed such procedures. Techniques used in industry should be applied when possible. To protect the integrity of manufacturers' drug products during compounding in hospitals, every hospital admixture service must have its own quality-control system. PMID:6650523

  16. Principles and Practices for Quality Assurance and Quality Control

    USGS Publications Warehouse

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  17. 21 CFR 640.56 - Quality control test for potency.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control test for potency. (a) Quality control tests for potency of antihemophilic factor shall be...

  18. 21 CFR 640.56 - Quality control test for potency.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control test for potency. (a) Quality control tests for potency of antihemophilic factor shall be...

  19. Iron-control additives improve acidizing

    SciTech Connect

    Walker, M.; Dill, W. ); Besler, M. )

    1989-07-24

    Iron sulfide and sulfur precipitation in sour wells can be controlled with iron-sequestering agents and sulfide modifiers. Oil production has been routinely increased in sour wells where precipitation of iron sulfide and elemental sulfur has been brought under control. Production increases have been especially noteworthy on wells that had a history of rapid production decline after acid stimulation. Twenty-fold production increases have been recorded. Key to the production increase has been to increase permeability with: Iron chelating agents that control precipitation of iron sulfide. A sulfide modifier that reduces precipitation of solids in the presence of excessive amounts of hydrogen sulfide and prevents precipitation of elemental sulfur.

  20. Analytical laboratory quality control charting

    SciTech Connect

    O'Bryan, Ervin F.

    2001-06-11

    In life the importance of setting goals is stressed. The desired end result must be envisioned to chart a path and determine indicators to provide feedback on the process. Quality does not happen by accident but is achieved through a constant process of setting goals, process development, monitoring process indicators, fine tuning the process, and achieving results. These goals are to be focused and clearly measurable. In industry and life the setting of goals with clear process indicators is often difficult because of the variable end result and scarcity of measurements. Laboratories are fortunate in that they have a plethora of measurements with known or desired end results (controls) to monitor the process and give instantaneous feedback on quality. A key quality tool used by the laboratory to monitor and evaluate the lab processes is control charting. When properly utilized Quality Control (QC) Charts allow labs to be proactive in addressing problems rather than reactive. Several methods are available for control charting and some are listed in the references/information sources. The content for this paper is based on the control-charting program utilized at the Department of Energy's Fernald site. This control-charting program has specific areas of emphasis, simple charts, trend analyses, and effective follow-up.

  1. Quality control programme in mammography: second level quality controls.

    PubMed

    Nassivera, E; Nardin, L

    1997-06-01

    Mammography is the most reliable method by which to detect lesions in the breast. Since contrast between normal and pathological areas in the breast is extremely low, mammographic image quality should reach high standards without exceeding acceptable exposure levels for the breast. A quality control programme in mammography has been implemented. This programme is subdivided into two levels. The first consists of simple daily checks of image quality and film processing, while the second deals with more complex checks of mammographic unit, screen-film system, darkroom, illuminators, viewing conditions and reference dose determination. The values of all the parameters undergoing measurement are compared with the limiting values given by National and International Protocols. This paper describes the second level controls carried out every 6 months by the medical physicist. The parameters described are only those which have been studied and analysed in detail since the quality control programme in mammography was implemented. Such parameters (kilovoltage, focal spot dimension, half value layer, tube output, automatic exposure control system, screen-film characteristic curve and mean glandular dose) were measured during the period 1991-1995 and the results summarised. The values obtained prove the constant correct functioning of the equipment. PMID:9227255

  2. 10 CFR 26.167 - Quality assurance and quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Quality assurance and quality control. 26.167 Section 26.167 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories Certified by the Department of Health and Human Services § 26.167 Quality assurance and quality control. (a) Quality assurance program. Each HHS-certified laboratory...

  3. 10 CFR 26.167 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Quality assurance and quality control. 26.167 Section 26.167 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories Certified by the Department of Health and Human Services § 26.167 Quality assurance and quality control. (a) Quality assurance program. Each HHS-certified laboratory...

  4. 10 CFR 26.167 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Quality assurance and quality control. 26.167 Section 26.167 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Laboratories Certified by the Department of Health and Human Services § 26.167 Quality assurance and quality control. (a) Quality assurance program. Each HHS-certified laboratory...

  5. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Quality assurance and quality control. 26.137 Section 26.137 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.137 Quality assurance and quality control. (a) Quality assurance program. Each licensee...

  6. 10 CFR 26.137 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Quality assurance and quality control. 26.137 Section 26.137 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.137 Quality assurance and quality control. (a) Quality assurance program. Each licensee...

  7. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is... quality control frequencies by using statistical process control to monitor equipment performance on...

  8. CONTROL ROD ALLOY CONTAINING NOBLE METAL ADDITIONS

    DOEpatents

    Anderson, W.K.; Ray, W.E.

    1960-05-01

    Silver-base alloys suitable for use in the fabrication of control rods for neutronic reactors are given. The alloy consists of from 0.5 wt.% to about 1.5 wt.% of a noble metal of platinum, ruthenium, rhodium, osmium, or palladium, up to 10 wt.% of cadmium, from 2 to 20 wt.% indium, the balance being silver.

  9. Silage Microbiology and Its Control through Additives

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Ensiling is a method of preserving a moist crop. A moist crop can support the growth of a wide range of microorganisms, most of which will degrade the nutrient value to livestock. However, ensiling generally controls microbial activity by a combination of an anaerobic environment and a natural ferme...

  10. Microstructural Control of Additively Manufactured Metallic Materials

    NASA Astrophysics Data System (ADS)

    Collins, P. C.; Brice, D. A.; Samimi, P.; Ghamarian, I.; Fraser, H. L.

    2016-07-01

    In additively manufactured (AM) metallic materials, the fundamental interrelationships that exist between composition, processing, and microstructure govern these materials’ properties and potential improvements or reductions in performance. For example, by using AM, it is possible to achieve highly desirable microstructural features (e.g., highly refined precipitates) that could not otherwise be achieved by using conventional approaches. Simultaneously, opportunities exist to manage macro-level microstructural characteristics such as residual stress, porosity, and texture, the last of which might be desirable. To predictably realize optimal microstructures, it is necessary to establish a framework that integrates processing variables, alloy composition, and the resulting microstructure. Although such a framework is largely lacking for AM metallic materials, the basic scientific components of the framework exist in literature. This review considers these key components and presents them in a manner that highlights key interdependencies that would form an integrated framework to engineer microstructures using AM.

  11. Quality control of EUVE databases

    NASA Technical Reports Server (NTRS)

    John, L. M.; Drake, J.

    1992-01-01

    The publicly accessible databases for the Extreme Ultraviolet Explorer include: the EUVE Archive mailserver; the CEA ftp site; the EUVE Guest Observer Mailserver; and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public EUVE databases are working properly, and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this poster, we describe the Quality Assurance (QA) procedures we have developed from the approach of QA as a service organization, thus reflecting the overall EUVE philosophy of Quality Assurance integrated into normal operating procedures, rather than imposed as an external, post facto, control mechanism.

  12. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Quality assurance and quality control. 136.7 Section 136.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.7 Quality assurance and quality control. The...

  13. [Internal Quality Control and External Quality Assessment on POCT].

    PubMed

    Kuwa, Katsuhiko

    2015-02-01

    The quality management (QM) of POCT summarizes its internal quality control (IQC) and external quality assessment (EQA). For QM requirements in POCT, ISO 22870-Point-of-care testing (POCT) -Requirements for quality and competence and ISO 15189-Medical laboratories-Requirements for quality and competence, it is performed under the guidance of the QM committee. The role of the POC coordinator and/or medical technologist of the clinical laboratory is important. On measurement performance of POCT devices, it is necessary to confirm data on measurement performance from the manufacturer other than those in the inserted document. In the IQC program, the checking and control of measurement performance are the targets. On measurements of QC samples by the manufacturer, it is essential to check the function of devices. In addition, regarding the EQA program, in 2 neighboring facilities, there is an effect to confirm the current status of measurement and commutability assessment in these laboratories using whole blood along with residual blood samples from daily examinations in the clinical laboratory. PMID:26529974

  14. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data...

  15. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data...

  16. 23 CFR 1340.8 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... OBSERVATIONAL SURVEYS OF SEAT BELT USE Survey Design Requirements § 1340.8 Quality control. (a) Quality control... control monitors involved in seat belt use surveys shall have received training in data...

  17. Quality Control of Meteorological Observations

    NASA Technical Reports Server (NTRS)

    Collins, William; Dee, Dick; Rukhovets, Leonid

    1999-01-01

    For the first time, a problem of the meteorological observation quality control (QC) was formulated by L.S. Gandin at the Main Geophysical Observatory in the 70's. Later in 1988 L.S. Gandin began adapting his ideas in complex quality control (CQC) to the operational environment at the National Centers for Environmental Prediction. The CQC was first applied by L.S.Gandin and his colleagues to detection and correction of errors in rawinsonde heights and temperatures using a complex of hydrostatic residuals.Later, a full complex of residuals, vertical and horizontal optimal interpolations and baseline checks were added for the checking and correction of a wide range of meteorological variables. some other of Gandin's ideas were applied and substantially developed at other meteorological centers. A new statistical QC was recently implemented in the Goddard Data Assimilation System. The central component of any quality control is a buddy check which is a test of individual suspect observations against available nearby non-suspect observations. A novel feature of this test is that the error variances which are used for QC decision are re-estimated on-line. As a result, the allowed tolerances for suspect observations can depend on local atmospheric conditions. The system is then better able to accept extreme values observed in deep cyclones, jet streams and so on. The basic statements of this adaptive buddy check are described. Some results of the on-line QC including moisture QC are presented.

  18. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture... MICHIGAN, NEW YORK, PENNSYLVANIA, OREGON, UTAH, WASHINGTON, AND WISCONSIN Order Regulating Handling Quality Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  19. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this... establish, with the approval of the Secretary, such minimum quality and inspection requirements...

  20. Towards quality control of food using terahertz

    NASA Astrophysics Data System (ADS)

    Ung, B. S.-Y.; Fischer, B. M.; Ng, B. W.-H.; Abbott, D.

    2007-12-01

    Terahertz radiation or T-rays, show promise in quality control of food products. As T-rays are inherently sensitive to water, they are very suitable for moisture detection. This proves to be a valuable asset in detecting the moisture content of dried food, a critical area for some products. As T-rays are transparent to plastics, food additives can also be probed through the packaging, providing checks against a manufacturer's claims, such as the presence of certain substances in foods.

  1. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 2 2011-07-01 2011-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts...

  2. [Quality control in clinical trials].

    PubMed

    Fukushima, M

    1996-01-01

    Quality control (QC) in clinical trials means the procedures which insure protection of human subjects from research risk, reliability of the data, and thereby assures internal consistency. This has been developed since 1970s in the US, by establishing various regulations which are now called GCP. From the viewpoint of total QC, it should be emphasized that rigorous review of protocol by the Institutional Review Board and obtaining Informed Consent are prerequisites for insuring the quality of the given trial at high scientific level. When pursuing a clinical trial, first of all, facilities of the institutions and the ability of investigators must be of high quality. For this reason, at each institution previous data related to trials should be thoroughly reviewed and analyzed prior to developing a protocol. Educational courses in QC in clinical practice are invaluable. QC of diagnosis means, for example, central pathology review and standardization of diagnostic procedures and process. Secondly, at each institution, data managers collect the data and submit them to the central office at the indicated time. In order to evolve clinical trial, continuous education for data managers and expansion of their job are encouraged. Thirdly, at the statistical center independent from the research group office, subject-specific data managers, the biostatistical staff, must check submitted forms for completeness, consistency and accuracy. Finally, at the data analysis, quality evaluation of the research should also be carried out. Throughout the trial, monitoring and audit are particularly important to assure quality. The sponsor has the responsibility of monitoring the trial and make rigorous onsite visits, and the individual study group also have a monitoring program, while the FDA and the NCI audit by themselves. The purpose of audit is not only to assure data reliability but also to check out patient compliance to drug, education as to regulations and rules of clinical

  3. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in...

  4. 42 CFR 84.256 - Quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in...

  5. Research of data quality control based on quality grading

    NASA Astrophysics Data System (ADS)

    Liu, Shuang Hong; Yu, Jian Guo; Yu, Yong Ling

    2012-01-01

    To solve the problem of data quality in data warehouse, the process of data stream in data warehouse and the factors influencing data quality were analyzed; a method for controlling data quality based on quality grading was proposed and the frame of data quality grading system was established. In each process of ETL, the data quality grading system would execute script to calculate values, such as total, component and standard measures in accordance with the definition of Unit Measure, so as to get representation indexes; and then the quality report would be generated according to the indexes and the quality would be graded. The method is applicable to various data warehouse systems.

  6. Research of data quality control based on quality grading

    NASA Astrophysics Data System (ADS)

    Liu, Shuang Hong; Yu, Jian Guo; Yu, Yong Ling

    2011-12-01

    To solve the problem of data quality in data warehouse, the process of data stream in data warehouse and the factors influencing data quality were analyzed; a method for controlling data quality based on quality grading was proposed and the frame of data quality grading system was established. In each process of ETL, the data quality grading system would execute script to calculate values, such as total, component and standard measures in accordance with the definition of Unit Measure, so as to get representation indexes; and then the quality report would be generated according to the indexes and the quality would be graded. The method is applicable to various data warehouse systems.

  7. Poly(oxyalkylene) aminoether carbamates as deposit control additives

    SciTech Connect

    Plavac, F.

    1987-09-22

    This patent describes deposit control additives to maintain cleanliness in internal combustion engines which are provided. The additives are hydrocarbyl-terminated poly(oxyalkylene) aminohydrocarbyloxyhydrocarbyl carbamates, also referred to as polyether aminoether carbamates.

  8. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....359 Quality control. Quality control measures shall insure that emission testing equipment is... 40 Protection of Environment 2 2013-07-01 2013-07-01 false Quality control. 51.359 Section 51.359... of tests) which fall into the testing categories identified. Alternatives or exceptions to...

  9. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....359 Quality control. Quality control measures shall insure that emission testing equipment is... 40 Protection of Environment 2 2014-07-01 2014-07-01 false Quality control. 51.359 Section 51.359... of tests) which fall into the testing categories identified. Alternatives or exceptions to...

  10. 40 CFR 51.359 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....359 Quality control. Quality control measures shall insure that emission testing equipment is... 40 Protection of Environment 2 2012-07-01 2012-07-01 false Quality control. 51.359 Section 51.359... of tests) which fall into the testing categories identified. Alternatives or exceptions to...

  11. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  12. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which...

  13. 7 CFR 981.42 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in...

  14. 7 CFR 930.44 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  15. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product...

  16. 14 CFR 21.139 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which...

  17. Soil quality changes after topsoil addition to eroded land

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Soil-landscape rehabilitation within eroded fields can be accomplished by moving topsoil from depositional to eroded landscape positions. The purpose is to improve soil quality and productivity of the upper root zone in eroded areas of the field. Changes in soil quality may be estimated through chan...

  18. Quality assurance and quality control in monitoring programs

    USGS Publications Warehouse

    Shampine, W.J.

    1993-01-01

    There are three general characteristics of the data to be collected in a monitoring program that should be met in order to maximize the use and value of the data: the data quality should be known the data type and quality should be consistent and comparable, and the data should be available and accessible. Potential problems with each of these characteristics are addressed effectively by quality assurance and quality control. One of the most important aspects of quality assurance in a monitoring program is the development of a quality assurance plan, which should identify clearly the quality of the data needed and describe in detail the planned actions to provide confidence that the program will meet its stated objectives. Quality control data, which allow for the quality and suitability of the environmental data to be evaluated and ascertained, should be collected and utilized as an integral part of the QA effort associated with a monitoring program.

  19. Quality Control by Artificial Vision

    SciTech Connect

    Lam, Edmond Y.; Gleason, Shaun Scott; Niel, Kurt S.

    2010-01-01

    Computational technology has fundamentally changed many aspects of our lives. One clear evidence is the development of artificial-vision systems, which have effectively automated many manual tasks ranging from quality inspection to quantitative assessment. In many cases, these machine-vision systems are even preferred over manual ones due to their repeatability and high precision. Such advantages come from significant research efforts in advancing sensor technology, illumination, computational hardware, and image-processing algorithms. Similar to the Special Section on Quality Control by Artificial Vision published two years ago in Volume 17, Issue 3 of the Journal of Electronic Imaging, the present one invited papers relevant to fundamental technology improvements to foster quality control by artificial vision, and fine-tuned the technology for specific applications. We aim to balance both theoretical and applied work pertinent to this special section theme. Consequently, we have seven high-quality papers resulting from the stringent peer-reviewing process in place at the Journal of Electronic Imaging. Some of the papers contain extended treatment of the authors work presented at the SPIE Image Processing: Machine Vision Applications conference and the International Conference on Quality Control by Artificial Vision. On the broad application side, Liu et al. propose an unsupervised texture image segmentation scheme. Using a multilayer data condensation spectral clustering algorithm together with wavelet transform, they demonstrate the effectiveness of their approach on both texture and synthetic aperture radar images. A problem related to image segmentation is image extraction. For this, O'Leary et al. investigate the theory of polynomial moments and show how these moments can be compared to classical filters. They also show how to use the discrete polynomial-basis functions for the extraction of 3-D embossed digits, demonstrating superiority over Fourier

  20. Business quality control in issuing life insurance.

    PubMed

    Roberts, N K

    1999-01-01

    Fraud investigation and fraud control are entirely different processes. Similarly the auditing of a life insurance company and the issuing of life insurance policies and business quality control are not the same. Business quality control and fraud control have much in common. In this article, these similarities are explored and a case is made that companies issuing life insurance policies should consider the business quality control approach rather than the more traditional investigatory methods. PMID:10539385

  1. Quality Control of EUVE Databases

    NASA Astrophysics Data System (ADS)

    John, Linda M.

    1993-01-01

    The publicly accessible databases for the Extreme Ultraviolet Explorer (EUVE) include: the EUVE Archive Mailserver, the Center for EUV Astrophysics ftp site, the EUVE Guest Observer Mailserver, and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public databases are working properly and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this paper, we describe the quality assurance (QA) procedures we have developed from approaching QA as a service organization; this approach reflects the overall EUVE philosophy of QA integrated into normal operating procedures, rather than imposed as an external, post-facto, control mechanism.

  2. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Quality assurance and quality control. 136.7 Section 136.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... referred to as a spiked blank, or laboratory control sample (LCS); (v) Matrix spike (MS) and matrix...

  3. QUALITY CONTROL - VARIABILITY IN PROTOCOLS

    EPA Science Inventory

    The EPA Risk Reduction Engineering Laboratory’s Quality Assurance Office, which published the popular pocket guide Preparing Perfect Project Plans, is now introducing another quality assurance reference aid. The document Variability in Protocols (VIP) was initially designed as a ...

  4. Quality control in the year 2000

    PubMed Central

    Schade, Bernd

    1992-01-01

    ‘Just-in-time’ production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and problem-solving will be easier. To achieve just-in-time release, advanced automated systems like robots will become the workhorses in QC for high volume pharmaceutical production. The requirements for these systems are extremely high in terms of quality, reliability and ruggedness. Crucial for the success might be advances in use of microelectronics for error checks, system recording, trouble shooting, etc. as well as creative new approaches (for example the use of redundant assay systems). PMID:18924930

  5. Quality control in the year 2000.

    PubMed

    Schade, B

    1992-01-01

    'Just-in-time' production is a prerequisite for a company to meet the challenges of competition. Manufacturing cycles have been so successfully optimized that release time now has become a significant factor. A vision for a major quality-control (QC) contribution to profitability in this decade seems to be the just-in-time release. Benefits will go beyond cost savings for lower inventory. The earlier detection of problems will reduce rejections and scrap. In addition, problem analysis and problem-solving will be easier. To achieve just-in-time release, advanced automated systems like robots will become the workhorses in QC for high volume pharmaceutical production. The requirements for these systems are extremely high in terms of quality, reliability and ruggedness. Crucial for the success might be advances in use of microelectronics for error checks, system recording, trouble shooting, etc. as well as creative new approaches (for example the use of redundant assay systems). PMID:18924930

  6. Computers and quality control in nuclear medicine.

    PubMed

    Brookeman, V A

    1978-04-01

    The general topic of computers and nuclear medicine quality control may be approached from two main areas; controlling the quality of computerized studies, and computer applications in general nuclear medicine quality control. Overlap occurs when quality control of computer studies is performed by the computer itself. The uses of computers in record-keeping and in quality control of imaging instrumentation and in vitro studies, including radioimmunoassay, are discussed in this review. Aspects of quality control for computerized clinical cardiovascular, cerebral, and renal studies and emission computed tomography are reviewed, including consideration of difficulties and inaccuracies involved in the studies. Any automatic computer analysis program should incorporate adequate checks and error detection protocols and should illustrate results for verification. Current routine quality control procedures using the computer unfortunately are few. Quality control criteria are needed for camera/computer systems in high count rate clinical applications, and increasing emphasis should be aimed at quality control of those computerized dynamic and function studies in current clinical use. The computer has a valuable potential for nuclear medicine quality control. In vitro and computerized in vivo studies can be analyzed by readily available statistical programs, and variances can be monitored continuously. Computers can calibrate and monitor instrument performance regularly, and can handle managerial and clerical duties such as bookkeeping. PMID:684439

  7. One of two rotodip feeders used to control addition of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    One of two rotodip feeders used to control addition of alum solution into the water - Division Avenue Pumping Station & Filtration Plant, West 45th Street and Division Avenue, Cleveland, Cuyahoga County, OH

  8. Control of pyrite addition in coal liquefaction process

    DOEpatents

    Schmid, Bruce K.; Junkin, James E.

    1982-12-21

    Pyrite addition to a coal liquefaction process (22, 26) is controlled (118) in inverse proportion to the calcium content of the feed coal to maximize the C.sub.5 --900.degree. F. (482.degree. C.) liquid yield per unit weight of pyrite added (110). The pyrite addition is controlled in this manner so as to minimize the amount of pyrite used and thus reduce pyrite contribution to the slurry pumping load and disposal problems connected with pyrite produced slag.

  9. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA...

  10. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control. 74.6 Section 74.6 Mineral... control. The applicant shall describe the way in which each lot of components will be sampled and tested... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA...

  11. Quality Control in Small Groups

    NASA Astrophysics Data System (ADS)

    Lemmens, L. F.

    2008-11-01

    The smallness of some groups in a set up to control the quality of a service using questionnaires limits the size of the samples, this limitation has several consequences. Indeed the common approach used for relatively large groups, based on the central limit theorem and the law of large numbers, cannot be used anymore to construct estimators for the parameters of the model. Using an inverse probability will lift these restrictions. A questionnaire is a collection of items. In an item the respondent indicates on a Likert scale his or her agreement with a statement. Dimensions are a set of items dealing with one aspect of the service. In a questionnaire several dimensions are addressed but usually the items are presented in a random sequence. The model for an item is hierarchical with following components: a multivariate hypergeometric model takes the sampling in a finite population into account, the multinomial serves as a prior for the sampling and the Dirichlet-distribution serves as a prior for the multinomials. The composition of dimensions allows to use the posterior for one of the items as a prior for another item of that dimension and so on. After analysis of several questionnaires using this model, the reliability of the responses from some respondents turned out to be a key-problem, in the sense the responses can be classified into at least two classes and a decision rule had to be developed to neglect some of them. The influence of rejecting some answers, on the confidence for the most plausible statement can be estimated. This leads often to the result that there is only minimal evidence for the most probable statement.

  12. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    ERIC Educational Resources Information Center

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  13. Are changes in glycaemic control associated with diabetes-specific quality of life and health status in screen-detected type 2 diabetes patients? Four-year follow up of the ADDITION-Cambridge cohort

    PubMed Central

    Kuznetsov, L; Long, G H; Griffin, S J; Simmons, R K

    2015-01-01

    Background Interventions that improve HbA1c levels do not necessarily improve health-related quality of life (QoL). This issue may be particularly relevant in asymptomatic diabetes patients detected earlier in the course of the disease. Methods HbA1c, diabetes-specific QoL (ADDQoL) and health status were measured in 510 screen-detected diabetes patients from the ADDITION-Cambridge trial at 1 and 5 years post diagnosis. Multivariable logistic/linear regression was used to quantify the longitudinal association between change in HbA1c from 1 to 5 years and ADDQoL and health status at 5 years, adjusting for age, sex, education and trial group; alcohol consumption, smoking, physical activity, plasma vitamin C, HbA1c, ADDQoL or health status at 1 year, and glucose-lowering medication at 5 years. Results From 1 to 5 years, median HbA1c interquartile range increased from 6.3% (5.9–6.8) to 6.8% (6.4–7.4); the median ADDQoL score and mean health status physical health summary score decreased from -0.4 (-1 to -0.08) to -0.5 (-1.08 to -0.09) (suggesting an adverse impact of diabetes on QoL) and by -0.79 (8.94) points, respectively. Increases in HbA1c were independently associated with reporting a negative impact of diabetes on QoL (OR = 1.38, 95% CI: 1.03 to 1.85) but not with the health status summary scores. Conclusions Increases in HbA1c from 1 to 5 years post-diagnosis were independently associated with increased odds of reporting a negative impact of diabetes on QoL. While our results suggest that efforts to reduce HbA1c do not adversely affect health-related QoL, large numbers of participants still report a negative impact of diabetes on their QoL 5 years post-diagnosis. © 2014 The Authors. Diabetes/Metabolism Research and Reviews published by John Wiley & Sons, Ltd. PMID:24817063

  14. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality... to maintain its quality prior to assembly of each sampler unit. In order to assure that the...

  15. Handling qualities requirements for control configured vehicles

    NASA Technical Reports Server (NTRS)

    Woodcock, R. J.; George, F. L.

    1976-01-01

    The potential effects of fly by wire and control configured vehicle concepts on flying qualities are considered. Failure mode probabilities and consequences, controllability, and dynamics of highly augmented aircraft are among the factors discussed in terms of design criteria.

  16. Quality control education in the community college

    NASA Technical Reports Server (NTRS)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  17. Professional Development for Water Quality Control Personnel.

    ERIC Educational Resources Information Center

    Shepard, Clinton Lewis

    This study investigated the availability of professional development opportunities for water quality control personnel in the midwest. The major objective of the study was to establish a listing of educational opportunities for the professional development of water quality control personnel and to compare these with the opportunities technicians…

  18. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DEFENSE PROGRAMMATIC REGULATIONS FOR THE COMPREHENSIVE EVERGLADES RESTORATION PLAN CERP Implementation... quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that will be produced by a Project Delivery Team. The quality control plan shall be included in the...

  19. Quality Control Technician Curriculum. An Elusive Butterfly.

    ERIC Educational Resources Information Center

    Holler, Michael

    Defining and developing a quality control technician curriculum for an associate degree program is a difficult and puzzling job. There are as many definitions of quality control and curriculum ideas as there are educators asked. However, one could start by dividing the field into its major areas--heavy manufacturing, maintenance, research, and…

  20. 30 CFR 74.6 - Quality control.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6...

  1. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  2. Quality-control analytical methods: continuous quality improvement.

    PubMed

    Venti, Eden M

    2006-01-01

    It is vital that all compounding pharmacies have a continuous quality improvement program in place by way of standard operating procedures to assure that patients receive high-quality preparations. The program should take into consideration any federal and state regulatory requirements, as well as professional association expectations. Quality control measurements and regular review of those measurements are the foundations of a good quality plan. All pharmacy personnel should be aware of the importance of reporting potential internal quality concerns or problems and should be encouraged to do so without fear of repercussions. Ideally, an error-free compounding pracitice would be the goal. Since this is not practical, quality issues should not be viewed as problems, but as opportunities to improve compounding practices by correcting, before they become pervasive, the processes used in the preparation of prescriptions. PMID:23974418

  3. Substrate-controlled Michael additions of chiral ketones to enones.

    PubMed

    Fàbregas, Mireia; Gómez-Palomino, Alejandro; Pellicena, Miquel; Reina, Daniel F; Romea, Pedro; Urpí, Fèlix; Font-Bardia, Mercè

    2014-12-01

    Substrate-controlled Michael additions of the titanium(IV) enolate of lactate-derived ketone 1 to acyclic α,β-unsaturated ketones in the presence of a Lewis acid (TiCl4 or SnCl4) provide the corresponding 2,4-anti-4,5-anti dicarbonyl compounds in good yields and excellent diastereomeric ratios. Likely, the nucleophilic species involved in such additions are bimetallic enolates that may add to enones through cyclic transition states. Finally, further studies indicate that a structurally related β-benzyloxy chiral ketone can also participate in such stereocontrolled conjugate additions. PMID:25423031

  4. Water Quality Control, Curriculum Guide.

    ERIC Educational Resources Information Center

    Washington City Board of Education, NC.

    Activities which study how water is used, contaminated, and treated or purified are presented in this curriculum guide, culminating in the investigation of a local water quality problem. Designed as a 12 week mini-course for students in grades eight and nine, the guide first presents a review of the content, objectives, major concepts, and sources…

  5. mRNA quality control goes transcriptional

    PubMed Central

    Kilchert, Cornelia; Vasiljeva, Lidia

    2013-01-01

    Eukaryotic mRNAs are extensively processed to generate functional transcripts, which are 5′ capped, spliced and 3′ polyadenylated. Accumulation of unprocessed (aberrant) mRNAs can be deleterious for the cell, hence processing fidelity is closely monitored by QC (quality control) mechanisms that identify erroneous transcripts and initiate their selective removal. Nucleases including Xrn2/Rat1 and the nuclear exosome have been shown to play an important role in the turnover of aberrant mRNAs. Recently, with the growing appreciation that mRNA processing occurs concomitantly with polII (RNA polymerase II) transcription, it has become evident that QC acts at the transcriptional level in addition to degrading aberrant RNAs. In the present review, we discuss mechanisms that allow cells to co-transcriptionally initiate the removal of RNAs as well as down-regulate transcription of transcripts where processing repeatedly fails. PMID:24256272

  6. Control by quality: proposition of a typology.

    PubMed

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  7. Ultrafast amplifier additive timing jitter characterization and control.

    PubMed

    Casanova, Alexis; D'Acremont, Quentin; Santarelli, Giorgio; Dilhaire, Stefan; Courjaud, Antoine

    2016-03-01

    We report on the characterization and long-term compensation of additive timing jitter introduced by a femtosecond ytterbium regenerative amplifier with a 100 kHz repetition rate. A balanced optical cross-correlation technique is used to generate a jitter error signal. This approach is well suited to characterize the additive timing jitter of Yb amplifiers seeded by narrow spectrum Yb oscillators. The balanced optical cross-correlator is in a noncollinear configuration allowing a background free coindence detection. This setup enables the measurement of additive timing jitter from the amplifier, with a noise floor of 300 as integrated from 10 Hz to 10 kHz. The measured additive timing jitter level is about 5 fs, integrated from 0.1 Hz to 10 kHz. The amplifier timing drift characterization and control are performed for more than an hour. PMID:26974074

  8. [Comparing quality measurements Part 2: control charts].

    PubMed

    Kottner, Jan; Hauss, Armin

    2013-04-01

    Comparative quality measurements and evaluations in nursing play significant roles. Quality measures are affected by systematic and random error. Statistical Process Control (SPC) offers a method to take random variation adequately into account. In this article, control charts are introduced. Those are graphical displays to show quality measures over time. Attribute variables can be displayed by p-, u- and c-control charts. Special cause variations within the processes can be detected by rules. If signs for special cause variations are absent, the process in considered being in statistical control showing common cause variation. A deviation of one data point greater than three standard deviations from the arithmetic mean is considered the strongest signal for non random variation within the process. Within quality improvement contexts control charts outperform traditional comparisons of means and spreads. PMID:23535476

  9. Quality Control Using Optical Probe Arrays

    NASA Astrophysics Data System (ADS)

    Stewart, Robert M.

    1989-01-01

    Low cost, optical probes, can be combined into an inspection array, and the go/no-go outputs can be analyzed by a high speed programmable logic controller (PLC). The PLC can be remotely addressed to change the desired level of quality control. The PLC can provide on-line data for blow-by-blow statistical process control (SPC).

  10. [Quality control of printed patient information].

    PubMed

    Herm, Kerstin; Linden, Michael

    2013-05-01

    Printed material is an important part in patient information and is called bibliotherapy. It is subject to quality control similar to any other types of treatment. This paper presents an outline of important quality criteria and methods of quality control. Important quality criteria are: (a) Correctness and validity of content evaluated by mentioning the expertise of the authors, appraisal through external experts, reference to scientific literature, and empirical tests of the content, (b) Readability in respect to text structure measured by the "Flesch-Reading-Ease-Formula" supported by fair graphical design including fond and structure of text, (c) Comprehensibility tested by feedback of patients or standardized by the Hamburg comprehensibility rating, (d) Utility including securing availability, acceptance, differential indication and use. Writing and publication of patient leaflets must be accompanied by quality control measures. PMID:23446824

  11. Quality Control Systems in Cardiac Aging

    PubMed Central

    Quarles, Ellen K; Dai, Dao-Fu; Tocchi, Autumn; Basisty, Nathan; Gitari, Lemuel; Rabinovitch, Peter S

    2015-01-01

    Cardiac aging is an intrinsic process that results in impaired cardiac function, along with cellular and molecular changes. These degenerative changes are intimately associated with quality control mechanisms. This review provides a general overview of the clinical and cellular changes which manifest in cardiac aging, and the quality control mechanisms involved in maintaining homeostasis and retarding aging. These mechanisms include autophagy, ubiquitin-mediated turnover, apoptosis, mitochondrial quality control and cardiac matrix homeostasis. Finally, we discuss aging interventions that have been observed to impact cardiac health outcomes. These include caloric restriction, rapamycin, resveratrol, GDF11, mitochondrial antioxidants and cardiolipin-targeted therapeutics. A greater understanding of the quality control mechanisms that promote cardiac homeostasis will help to understand the benefits of these interventions, and hopefully lead to further improved therapeutic modalities. PMID:25702865

  12. Emission control devices, fuel additive, and fuel composition changes.

    PubMed Central

    Piver, W T

    1977-01-01

    Emission control devices are installed to meet the exhaust standards of the Clean Air Act for carbon monoxide and hydrocarbons, and it is necessary to know, from a public health point of view, how exhaust emissions may be affected by changes in fuel additives and fuel composition. Since these topics are concerned with developing technologies, the available literature on exhaust emission characteristics and the limited information on health effects, is reviewed. PMID:71235

  13. Emission control devices, fuel additive, and fuel composition changes.

    PubMed

    Piver, W T

    1977-08-01

    Emission control devices are installed to meet the exhaust standards of the Clean Air Act for carbon monoxide and hydrocarbons, and it is necessary to know, from a public health point of view, how exhaust emissions may be affected by changes in fuel additives and fuel composition. Since these topics are concerned with developing technologies, the available literature on exhaust emission characteristics and the limited information on health effects, is reviewed. PMID:71235

  14. Mitochondrial Quality Control as a Therapeutic Target.

    PubMed

    Suliman, Hagir B; Piantadosi, Claude A

    2016-01-01

    In addition to oxidative phosphorylation (OXPHOS), mitochondria perform other functions such as heme biosynthesis and oxygen sensing and mediate calcium homeostasis, cell growth, and cell death. They participate in cell communication and regulation of inflammation and are important considerations in aging, drug toxicity, and pathogenesis. The cell's capacity to maintain its mitochondria involves intramitochondrial processes, such as heme and protein turnover, and those involving entire organelles, such as fusion, fission, selective mitochondrial macroautophagy (mitophagy), and mitochondrial biogenesis. The integration of these processes exemplifies mitochondrial quality control (QC), which is also important in cellular disorders ranging from primary mitochondrial genetic diseases to those that involve mitochondria secondarily, such as neurodegenerative, cardiovascular, inflammatory, and metabolic syndromes. Consequently, mitochondrial biology represents a potentially useful, but relatively unexploited area of therapeutic innovation. In patients with genetic OXPHOS disorders, the largest group of inborn errors of metabolism, effective therapies, apart from symptomatic and nutritional measures, are largely lacking. Moreover, the genetic and biochemical heterogeneity of these states is remarkably similar to those of certain acquired diseases characterized by metabolic and oxidative stress and displaying wide variability. This biologic variability reflects cell-specific and repair processes that complicate rational pharmacological approaches to both primary and secondary mitochondrial disorders. However, emerging concepts of mitochondrial turnover and dynamics along with new mitochondrial disease models are providing opportunities to develop and evaluate mitochondrial QC-based therapies. The goals of such therapies extend beyond amelioration of energy insufficiency and tissue loss and entail cell repair, cell replacement, and the prevention of fibrosis. This review

  15. Quality control of automated cell counters.

    PubMed

    Cembrowski, George S; Clarke, Gwen

    2015-03-01

    The hematology analyzers of today provide more reproducible analyses compared with those of a few decades ago, necessitating an evolution in hematology quality practices. The improved performance allows use of simple quality control rules. This improved performance also renders the repeat analysis of critical value specimens non value added. Some of the patient averaging techniques have become outmoded and need to be replaced by less complicated calculations but with truncation of predictable outlying populations. The ready availability of comparative peer quality control values helps to improve analyzer precision and accuracy, and simplifies instrument validation and calibration. PMID:25676372

  16. Teaching Quality Control with Chocolate Chip Cookies

    ERIC Educational Resources Information Center

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  17. [The quality of biological information: standardization and quality control].

    PubMed

    Giampaoli, S; Muti, P

    1992-01-01

    Some procedures and methods for the measurement of cardiovascular risk factor are described; in particular of anthropometric measurements (weight, height, arm circumference, wrist circumference, hip circumference) of blood pressure, of electrocardiogram and of blood samples for the preservation of biological specimens. Some advice for the quality control during screening activities are reported. PMID:1492736

  18. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES FOR THE ANALYSIS OF POLLUTANTS § 136.7 Quality... referred to as a spiked blank, or laboratory control sample (LCS); (v) Matrix spike (MS) and matrix spike duplicate (MSD), or laboratory fortified matrix (LFM) and LFM duplicate, may be used for suspected...

  19. QUALITY ASSURANCE AND QUALITY CONTROL FOR RADIOCHEMICAL ANALYSES AND MEASUREMENTS

    EPA Science Inventory

    Require that each batch of samples analyzed be accompanied by appropriate quality control samples to evaluate accuracy and precision of the results. Require a documented data review and validation process by a minimum of three people before data is released to the client. Requi...

  20. Quality control of antibodies for assay development.

    PubMed

    Schumacher, Sarah; Seitz, Harald

    2016-09-25

    Antibodies are used as powerful tools in basic research, for example, in biomarker identification, and in various forms for diagnostics, for example, identification of allergies or autoimmune diseases. Due to their robustness and ease of handling, immunoassays are favourite methods for investigation of various biological or medical questions. Nevertheless in many cases, additional analyses such as mass spectrometry are used to validate or confirm the results of immunoassays. To minimize the workload and to increase confidence in immunoassays, there are urgent needs for antibodies which are both highly specific and well validated. Unfortunately many commercially available antibodies are neither well characterized nor fully tested for cross-reactivities. Adequate quality control and validation of an antibody is time-consuming and can be frustrating. Such validation needs to be performed for every assay/application. However, where an antibody validation is successful, a highly specific and stable reagent will be on hand. This article describes the validation processes of antibodies, including some often neglected factors, as well as unspecific binding to other sample compounds in a multiparameter diagnostic assay. The validation consists of different immunological methods, with important assay controls, and is performed in relation to the development of a diagnostic test. PMID:26873787

  1. Network-based production quality control

    NASA Astrophysics Data System (ADS)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  2. Quality control of a teleradiology system

    NASA Astrophysics Data System (ADS)

    Lyche, David K.; Willis, Charles E.; Williamson, Morgan P.; Suitor, Charles T.; Romlein, John R.

    1996-04-01

    Teleradiology is being implemented in the U.S. military. Soft-copy reading of computed radiology (CR) images and film-digitizer (FD) images are becoming a common practice. The Medical Diagnostic Imaging Support (MDIS) Office at the Medical Advanced Technology Management Office (MATMO), Fort Detrick, Maryland, installed an 'off-the-shelf' DICOM teleradiology system by which CR images and FD images acquired at Hickam Air Force Base (AFB), Hawaii, are transmitted electronically over a T-1 telecommunications line to Tripler Army Medical Center (TAMC), Hawaii. The goal was to provide a diagnostic quality teleradiology system to the military services to extend the expertise and training of physicians to remote sites. In order to guarantee a diagnostic quality image throughout the system, a rigid set of quality control standards had to be designed and implemented. This poster presents the results of a successful teleradiology implementation where quality control is maintained throughout the imaging chain.

  3. Quality control by a mobile molecular workshop: Quality versus quantity

    NASA Astrophysics Data System (ADS)

    Sharma, Ajeet K.; Chowdhury, Debashish

    2010-09-01

    Ribosome is a molecular machine that moves on a messenger RNA (mRNA) track while, simultaneously, polymerizing a protein using the mRNA also as the corresponding template. We define, and analytically calculate, two different measures of the efficiency of this machine. However, we argue that its performance is evaluated better in terms of the translational fidelity and the speed with which it polymerizes a protein. We define both these quantities and calculate these analytically. Fidelity is a measure of the quality of the products, while the total quantity of products synthesized in a given interval depends on the speed of polymerization. We show that for synthesizing a large quantity of proteins, it is not necessary to sacrifice the quality. We also explore the effects of the quality control mechanism on the strength of mechanochemical coupling. We suggest experiments for testing some of the ideas presented here.

  4. Harmonisation Initiatives of Copernicus Data Quality Control

    NASA Astrophysics Data System (ADS)

    Vescovi, F. D.; Lankester, T.; Coleman, E.; Ottavianelli, G.

    2015-04-01

    The Copernicus Space Component Data Access system (CSCDA) incorporates data contributions from a wide range of satellite missions. Through EO data handling and distribution, CSCDA serves a set of Copernicus Services related to Land, Marine and Atmosphere Monitoring, Emergency Management and Security and Climate Change. The quality of the delivered EO products is the responsibility of each contributing mission, and the Copernicus data Quality Control (CQC) service supports and complements such data quality control activities. The mission of the CQC is to provide a service of quality assessment on the provided imagery, to support the investigation related to product quality anomalies, and to guarantee harmonisation and traceability of the quality information. In terms of product quality control, the CQC carries out analysis of representative sample products for each contributing mission as well as coordinating data quality investigation related to issues found or raised by Copernicus users. Results from the product analysis are systematically collected and the derived quality reports stored in a searchable database. The CQC service can be seen as a privileged focal point with unique comparison capacities over the data providers. The comparison among products from different missions suggests the need for a strong, common effort of harmonisation. Technical terms, definitions, metadata, file formats, processing levels, algorithms, cal/val procedures etc. are far from being homogeneous, and this may generate inconsistencies and confusion among users of EO data. The CSCDA CQC team plays a significant role in promoting harmonisation initiatives across the numerous contributing missions, so that a common effort can achieve optimal complementarity and compatibility among the EO data from multiple data providers. This effort is done in coordination with important initiatives already working towards these goals (e.g. INSPIRE directive, CEOS initiatives, OGC standards, QA4EO

  5. Effect of sorghum flour addition on in vitro starch digestibility, cooking quality, and consumer acceptability of durum wheat pasta.

    PubMed

    Khan, Imran; Yousif, Adel M; Johnson, Stuart K; Gamlath, Shirani

    2014-08-01

    Whole grain sorghum is a valuable source of resistant starch and polyphenolic antioxidants and its addition into staple food like pasta may reduce the starch digestibility. However, incorporating nondurum wheat materials into pasta provides a challenge in terms of maintaining cooking quality and consumer acceptability. Pasta was prepared from 100% durum wheat semolina (DWS) as control or by replacing DWS with either wholegrain red sorghum flour (RSF) or white sorghum flour (WSF) each at 20%, 30%, and 40% incorporation levels, following a laboratory-scale procedure. Pasta samples were evaluated for proximate composition, in vitro starch digestibility, cooking quality, and consumer acceptability. The addition of both RSF and WSF lowered the extent of in vitro starch digestion at all substitution levels compared to the control pasta. The rapidly digestible starch was lowered in all the sorghum-containing pastas compared to the control pasta. Neither RSF or WSF addition affected the pasta quality attributes (water absorption, swelling index, dry matter, adhesiveness, cohesiveness, and springiness), except color and hardness which were negatively affected. Consumer sensory results indicated that pasta samples containing 20% and 30% RSF or WSF had acceptable palatability based on meeting one or both of the preset acceptability criteria. It is concluded that the addition of wholegrain sorghum flour to pasta at 30% incorporation level is possible to reduce starch digestibility, while maintaining adequate cooking quality and consumer acceptability. PMID:25047068

  6. Cytochrome c oxidase: evolution of control via nuclear subunit addition.

    PubMed

    Pierron, Denis; Wildman, Derek E; Hüttemann, Maik; Markondapatnaikuni, Gopi Chand; Aras, Siddhesh; Grossman, Lawrence I

    2012-04-01

    According to theory, present eukaryotic cells originated from a beneficial association between two free-living cells. Due to this endosymbiotic event the pre-eukaryotic cell gained access to oxidative phosphorylation (OXPHOS), which produces more than 15 times as much ATP as glycolysis. Because cellular ATP needs fluctuate and OXPHOS both requires and produces entities that can be toxic for eukaryotic cells such as ROS or NADH, we propose that the success of endosymbiosis has largely depended on the regulation of endosymbiont OXPHOS. Several studies have presented cytochrome c oxidase as a key regulator of OXPHOS; for example, COX is the only complex of mammalian OXPHOS with known tissue-specific isoforms of nuclear encoded subunits. We here discuss current knowledge about the origin of nuclear encoded subunits and the appearance of different isozymes promoted by tissue and cellular environments such as hypoxia. We also review evidence for recent selective pressure acting on COX among vertebrates, particularly in primate lineages, and discuss the unique pattern of co-evolution between the nuclear and mitochondrial genomes. Finally, even though the addition of nuclear encoded subunits was a major event in eukaryotic COX evolution, this does not lead to emergence of a more efficient COX, as might be expected from an anthropocentric point of view, for the "higher" organism possessing large brains and muscles. The main function of these subunits appears to be "only" to control the activity of the mitochondrial subunits. We propose that this control function is an as yet under appreciated key point of evolution. Moreover, the importance of regulating energy supply may have caused the addition of subunits encoded by the nucleus in a process comparable to a "domestication scenario" such that the host tends to control more and more tightly the ancestral activity of COX performed by the mtDNA encoded subunits. PMID:21802404

  7. Protein quality control in the bacterial periplasm.

    PubMed

    Merdanovic, Melisa; Clausen, Tim; Kaiser, Markus; Huber, Robert; Ehrmann, Michael

    2011-01-01

    Protein quality control involves sensing and treatment of defective or incomplete protein structures. Misfolded or mislocalized proteins trigger dedicated signal transduction cascades that upregulate the production of protein quality-control factors. Corresponding proteases and chaperones either degrade or repair damaged proteins, thereby reducing the level of aggregation-prone molecules. Because the periplasm of gram-negative bacteria is particularly exposed to environmental changes and respective protein-folding stresses connected with the presence of detergents, low or high osmolarity of the medium, elevated temperatures, and the host's immune response, fine-tuned protein quality control systems are essential for survival under these unfavorable conditions. This review discusses recent advances in the identification and characterization of the key cellular factors and the emerging general principles of the underlying molecular mechanisms. PMID:21639788

  8. Post-translational Modification and Quality Control

    PubMed Central

    Wang, Xuejun; Pattison, J. Scott; Su, Huabo

    2013-01-01

    Protein quality control (PQC) functions to minimize the level and toxicity of misfolded proteins in the cell. PQC is performed by intricate collaboration among chaperones and target protein degradation. The latter is carried out primarily by the ubiquitin-proteasome system and perhaps autophagy. Terminally misfolded proteins that are not timely removed tend to form aggregates. Their clearance requires macroautophagy. Macroautophagy serves in intracellular quality control also by selectively segregating defective organelles (e.g., mitochondria) and targeting them for degradation by the lysosome. Inadequate PQC is observed in a large subset of failing human hearts with a variety of etiologies and its pathogenic role has been experimentally demonstrated. Multiple post-translational modifications (PTMs) can occur to substrate proteins and/or PQC machineries, promoting or hindering the removal of the misfolded proteins. This article highlights recent advances in PTMs-mediated regulation of intracellular quality control mechanisms and its known involvement in cardiac pathology. PMID:23329792

  9. Additive Effects of Stimulus Quality and Word Frequency on Eye Movements during Chinese Reading

    ERIC Educational Resources Information Center

    Liu, Pingping; Li, Xingshan; Han, Buxin

    2015-01-01

    Eye movements of Chinese readers were recorded for sentences in which high- and low-frequency target words were presented normally or with reduced stimulus quality in two experiments. We found stimulus quality and word frequency produced strong additive effects on fixation durations for target words. The results demonstrate that stimulus quality…

  10. Timing control improves seabed survey data quality

    SciTech Connect

    Green, R.

    1996-04-01

    Seateam has completed development of and field-proven the Dolphin data acquisition and timing system for high-density surveys offshore. The Dolphin project was initiated to improve quality control of survey sensor data and ensure time synchronization, thus leading to faster turnaround of seabed terrain information. Data received from survey sensors is asynchronous, so the system must provide for data correlation. This includes establishment of data latency, i.e., the time difference between data creation and timing of the message at first-byte arrival at the recording system. Until recently, asynchronous data from multiple sensors was collected by a single computer, regardless of whether it had additional intelligent or non-intelligent serial cards. This computer was fully responsible for time stamping all incoming data, plus associated storage and distribution. Though this initially sufficed and is still applicable to low-density data, increasingly larger data volumes required an associated boost in the capability to time stamp data prior to eventual correction.

  11. Quality Control of Diffusion Weighted Images

    PubMed Central

    Liu, Zhexing; Wang, Yi; Gerig, Guido; Gouttard, Sylvain; Tao, Ran; Fletcher, Thomas; Styner, Martin

    2013-01-01

    Diffusion Tensor Imaging (DTI) has become an important MRI procedure to investigate the integrity of white matter in brain in vivo. DTI is estimated from a series of acquired Diffusion Weighted Imaging (DWI) volumes. DWI data suffers from inherent low SNR, overall long scanning time of multiple directional encoding with correspondingly large risk to encounter several kinds of artifacts. These artifacts can be too severe for a correct and stable estimation of the diffusion tensor. Thus, a quality control (QC) procedure is absolutely necessary for DTI studies. Currently, routine DTI QC procedures are conducted manually by visually checking the DWI data set in a gradient by gradient and slice by slice way. The results often suffer from low consistence across different data sets, lack of agreement of different experts, and difficulty to judge motion artifacts by qualitative inspection. Additionally considerable manpower is needed for this step due to the large number of images to QC, which is common for group comparison and longitudinal studies, especially with increasing number of diffusion gradient directions. We present a framework for automatic DWI QC. We developed a tool called DTIPrep which pipelines the QC steps with a detailed protocoling and reporting facility. And it is fully open source. This framework/tool has been successfully applied to several DTI studies with several hundred DWIs in our lab as well as collaborating labs in Utah and Iowa. In our studies, the tool provides a crucial piece for robust DTI analysis in brain white matter study. PMID:24353379

  12. HPLC for quality control of polyimides

    NASA Technical Reports Server (NTRS)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  13. Quality control in the secretory assembly line.

    PubMed Central

    Helenius, A

    2001-01-01

    As a rule, only proteins that have reached a native, folded and assembled structure are transported to their target organelles and compartments within the cell. In the secretory pathway of eukaryotic cells, this type of sorting is particularly important. A variety of molecular mechanisms are involved that distinguish between folded and unfolded proteins, modulate their intracellular transport, and induce degradation if they fail to fold. This phenomenon, called quality control, occurs at several levels and involves different types of folding sensors. The quality control system provides a stringent and versatile molecular sorting system that guaranties fidelity of protein expression in the secretory pathway. PMID:11260794

  14. Natural additives to preserve quality and improve nutritional value of fresh-cut nectarine.

    PubMed

    Falagán, Natalia; Artés, Francisco; Aguayo, Encarna

    2016-07-01

    There is currently a high demand for natural and fresh-cut fruits. In this study, natural additives were applied to fresh-cut nectarines: (1) control, nontreated; (2) wedges were dipped in an antibrowning solution containing calcium ascorbate (AB); (3) and (4) wedges were dipped in an AB plus natural antimicrobial agents (vanillin or cinnamic acid, respectively). After these treatments, fresh-cut nectarines were packed and stored at 5 ℃ for eight days. The treatments AB+Vanillin and AB+Cinnamic inhibited microbial counts when compared with control and AB-only samples. The application of these solutions did not impart any aromas or off-flavors to nectarines and maintained firmness during the shelf-life period. AB solutions inhibited polyophenol oxidase action and reduced browning while stabilizing the soluble phenolic content, increasing consumer's acceptance. Nectarine wedges assimilated the ascorbic acid from the AB solution and retained it during the shelf-life period. The combination of an antibrowning agent and natural antimicrobials helped to control microbiological growth while maintaining high-quality parameters. They can be an attractive "green" alternative for organic fresh-cut products to other chemical sanitizers such as chlorine. PMID:26683483

  15. Rotorcraft flying qualities improvement using advanced control

    NASA Technical Reports Server (NTRS)

    Walker, D.; Postlethwaite, I.; Howitt, J.; Foster, N.

    1993-01-01

    We report on recent experience gained when a multivariable helicopter flight control law was tested on the Large Motion Simulator (LMS) at DRA Bedford. This was part of a study into the application of multivariable control theory to the design of full-authority flight control systems for high-performance helicopters. In this paper, we present some of the results that were obtained during the piloted simulation trial and from subsequent off-line simulation and analysis. The performance provided by the control law led to level 1 handling quality ratings for almost all of the mission task elements assessed, both during the real-time and off-line analysis.

  16. [Critical of the additive model of the randomized controlled trial].

    PubMed

    Boussageon, Rémy; Gueyffier, François; Bejan-Angoulvant, Theodora; Felden-Dominiak, Géraldine

    2008-01-01

    Randomized, double-blind, placebo-controlled clinical trials are currently the best way to demonstrate the clinical effectiveness of drugs. Its methodology relies on the method of difference (John Stuart Mill), through which the observed difference between two groups (drug vs placebo) can be attributed to the pharmacological effect of the drug being tested. However, this additive model can be questioned in the event of statistical interactions between the pharmacological and the placebo effects. Evidence in different domains has shown that the placebo effect can influence the effect of the active principle. This article evaluates the methodological, clinical and epistemological consequences of this phenomenon. Topics treated include extrapolating results, accounting for heterogeneous results, demonstrating the existence of several factors in the placebo effect, the necessity to take these factors into account for given symptoms or pathologies, as well as the problem of the "specific" effect. PMID:18387273

  17. Characterization and Control of Powder Properties for Additive Manufacturing

    NASA Astrophysics Data System (ADS)

    Strondl, A.; Lyckfeldt, O.; Brodin, H.; Ackelid, U.

    2015-03-01

    Powder characterization and handling in powder metallurgy are important issues and the required powder properties will vary between different component manufacturing processes. By understanding and controlling these, the final material properties for different applications can be improved and become more reliable. In this study, the metal powders used in additive manufacturing (AM) in terms of electron beam melting and selective laser melting have been investigated regarding particle size and shape using dynamic image analysis. In parallel, powder flow characteristics have been evaluated with a powder rheometer. Correlations within the results have been found between particle shape and powder flow characteristics that could explain certain effects of the powder processing in the AM processes. The impact, however, in the processing performance as well as in ultimate material properties was found to be limited.

  18. Protein Quality Control and Metabolism: Bidirectional Control in the Heart

    PubMed Central

    Wang, Zhao V.; Hill, Joseph A.

    2015-01-01

    The prevalence of heart disease, especially heart failure, continues to increase, and cardiovascular disease remains the leading cause of death worldwide. As cardiomyocytes are essentially irreplaceable, protein quality control is pivotal to cellular homeostasis and, ultimately, cardiac performance. Three evolutionarily conserved mechanisms – autophagy, the unfolded protein response, and the ubiquitin-proteasome system– act in concert to degrade misfolded proteins and eliminate defective organelles. Recent advances have revealed that these mechanisms are intimately associated with cellular metabolism. Going forward, comprehensive understanding of the role of protein quality control mechanisms in cardiac pathology will require integration of metabolic pathways and metabolic control. PMID:25651176

  19. Control of Microthrix parvicella by aluminium salts addition.

    PubMed

    Durban, N; Juzan, L; Krier, J; Gillot, S

    2016-01-01

    Aluminium and iron chloride were added to a biological nutrient removal pilot plant (1,500 population equivalent) treating urban wastewater to investigate the control of Microthrix parvicella bulking and foaming by metallic salts. Monitoring plant performance over two 6-month periods showed a slight impact on the removal efficiencies. Addition of metallic salts (Me; aluminium or aluminium + iron) at a concentration of 41 mmol Me(kg MLSS·d) (MLSS: mixed liquor suspended solids) over 70 days allowed a stabilization of the diluted sludge volume index (DSVI), whereas higher dosages (94 mmol Me(kg MLSS·d) over 35 days or 137 mmol Me(kg MLSS·d) over 14 days induced a significant improvement of the settling conditions. Microscopic observations showed a compaction of biological aggregates with an embedding of filamentous bacteria into the flocs that is not specific to M. parvicella as bacteria from phylum Chloroflexi are embedded too. The quantitative polymerase chain reaction targeting M. parvicella further indicated a possible growth limitation in addition to the flocculation impact at the high dosages of metallic salts investigated. DSVI appeared to be correlated with the relative abundance of M. parvicella. PMID:26819398

  20. Method for controlling a laser additive process using intrinsic illumination

    NASA Astrophysics Data System (ADS)

    Tait, Robert; Cai, Guoshuang; Azer, Magdi; Chen, Xiaobin; Liu, Yong; Harding, Kevin

    2015-05-01

    One form of additive manufacturing is to use a laser to generate a melt pool from powdered metal that is sprayed from a nozzle. The laser net-shape machining system builds the part a layer at a time by following a predetermined path. However, because the path may need to take many turns, maintaining a constant melt pool may not be easy. A straight section may require one speed and power while a sharp bend would over melt the metal at the same settings. This paper describes a process monitoring method that uses the intrinsic IR radiation from the melt pool along with a process model configured to establish target values for the parameters associated with the manufacture or repair. This model is based upon known properties of the metal being used as well as the properties of the laser beam. An adaptive control technique is then employed to control process parameters of the machining system based upon the real-time weld pool measurement. Since the system uses the heat radiant from the melt pool, other previously deposited metal does not confuse the system as only the melted material is seen by the camera.

  1. [Quality control of Maca (Lepidium meyenii)].

    PubMed

    Shu, Ji-cheng; Cui, Hang-qing; Huang, Ying-zheng; Huang, Xiao-ying; Yang, Ming

    2015-12-01

    To control the quality of Maca, the quality standard was established in this study. According to the methods recorded in the Appendix of Chinese Pharmacopoeia (2010 Edition), the water, extract, total ash, acid insoluble substance, and heavy metals inspections in Lepidium meyenii were carried out. N-benzyl-9Z, 12Z-octadecadienamide in L. meyenii was identified by TLC, and it was determined by HPLC. The results showed that the N-benzyl-9Z, 12Z-octadecadienamide identification of TLC was a strong mark and specificity. In content determination experiment, the linearity of N-benzyl-9Z, 12Z-octadecadienamide was in the range of 0.01-2 microg (r = 0.9998), and the average recovery (n=9) was 99.27% (RSD 2.0%). The methods were simple, accurate, with good reproducibility. It is suitable for quality control L. meyenii. PMID:27141660

  2. Additive Effects of Word Frequency and Stimulus Quality: The Influence of Trial History and Data Transformations

    ERIC Educational Resources Information Center

    Balota, David A.; Aschenbrenner, Andrew J.; Yap, Melvin J.

    2013-01-01

    A counterintuitive and theoretically important pattern of results in the visual word recognition literature is that both word frequency and stimulus quality produce large but additive effects in lexical decision performance. The additive nature of these effects has recently been called into question by Masson and Kliegl (in press), who used linear…

  3. Outsourcing University Degrees: Implications for Quality Control

    ERIC Educational Resources Information Center

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  4. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... will be produced by a Project Delivery Team. The quality control plan shall be included in the Project Management Plan and shall describe the procedures to be used to ensure compliance with technical and policy requirements during implementation. (b) During development of the Project Management Plan for each project,...

  5. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... will be produced by a Project Delivery Team. The quality control plan shall be included in the Project Management Plan and shall describe the procedures to be used to ensure compliance with technical and policy requirements during implementation. (b) During development of the Project Management Plan for each project,...

  6. 33 CFR 385.21 - Quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... will be produced by a Project Delivery Team. The quality control plan shall be included in the Project Management Plan and shall describe the procedures to be used to ensure compliance with technical and policy requirements during implementation. (b) During development of the Project Management Plan for each project,...

  7. Acoustic resonance techniques for quality control

    SciTech Connect

    Sinha, D.N.

    1992-09-01

    Acoustic resonance based nondestructive techniques are described that can be used for both process and quality control in manufacturing. The Acoustic Resonance Spectroscopy (AS) technique is highlighted for its capability in fluid property (flow, density, viscosity, and speed of sound) monitoring. Possible applications of these noninvasive techniques for textile manufacturing are pointed out.

  8. Acoustic resonance techniques for quality control

    SciTech Connect

    Sinha, D.N.

    1992-01-01

    Acoustic resonance based nondestructive techniques are described that can be used for both process and quality control in manufacturing. The Acoustic Resonance Spectroscopy (AS) technique is highlighted for its capability in fluid property (flow, density, viscosity, and speed of sound) monitoring. Possible applications of these noninvasive techniques for textile manufacturing are pointed out.

  9. Quality Control & Design in Science Learning

    ERIC Educational Resources Information Center

    Sumrall, William J.; Schillinger, Don

    2003-01-01

    One area of science education that is, at times, neglected involves lessons on technological concepts of these principles--designing, testing, and quality control. Instead, a focus upon science concepts from a pure, and unapplied, perspective is the norm. Thus, while students may learn the equation "mass divided by volume equals density," the…

  10. Effect of fructo-oligosaccharide and isomalto-oligosaccharide addition on baking quality of frozen dough.

    PubMed

    Park, Eun Young; Jang, Sung-Bum; Lim, Seung-Taik

    2016-12-15

    The baking quality of frozen doughs containing different levels of fructo-oligosaccharides (FO) or isomalto-oligosaccharides (IMO) (3-9%, w/w flour), and stored for 0-8weeks at -18°C, was examined. The addition of FO or IMO increased the proof volume of the dough and the loaf volume of bread prepared from frozen dough. A 6% addition of FO or IMO was optimum, giving the highest proof volume and bread loaf volume, but a higher concentration than 6% induced low baking quality including lower proof volume and bread loaf volume. The bread crumb was moister and softer after the addition of FO or IMO before, and even after, frozen storage. Darker crumb colour was observed in the bread after the addition of FO or IMO. The oligosaccharides added to the frozen dough were effective in improving the quality of bread made from frozen dough, except for resulting in a darker bread crumb. PMID:27451167

  11. Quality control and quality assurance procedures at the THOR BNCT facility.

    PubMed

    Liu, Yuan-Hao; Tsai, Pi-En; Lin, Yi-Chun; Huang, Chun-Kai; Liu, Hong-Ming; Jiang, Shiang-Huei

    2011-12-01

    Various quality control (QC) and quality assurance (QA) procedures of the boron neutron capture therapy (BNCT) beam at the Tsing Hua Open-pool Reactor (THOR) are established to ensure beam availability and quality. The QC/QA methods mainly employ foil activation and paired ionization chambers, respectively, for beam intensity check and dose assessment. Beam intensity is monitored on-line by using three dead-time corrected fission chambers. In addition to the periodic QC/QA activities regarding beam quality and the monitoring system, the quick QC/QA performed in an all-in-one phantom will be executed less than 70 min before the clinical treatment to guarantee beam quality. The QC/QA procedures have been gradually established and the actual performance satisfied the preset criteria defined for the BNCT facility at THOR. PMID:21605978

  12. The impact of quality control in RNA-seq experiments

    NASA Astrophysics Data System (ADS)

    Merino, Gabriela A.; Fresno, Cristóbal; Netto, Frederico; Dias Netto, Emmanuel; Pratto, Laura; Fernández, Elmer A.

    2016-04-01

    High throughput mRNA sample sequencing, known as RNA-seq, is as a powerful approach to detect differentially expressed genes starting from millions of short sequence reads. Although several workflows have been proposed to analyze RNA-seq data, the experiment quality control as a whole is not usually considered, thus potentially biasing the results and/or causing information lost. Experiment quality control refers to the analysis of the experiment as a whole, prior to any analysis. It not only inspects the presence of technical effects, but also if general biological assumptions are fulfilled. In this sense, multivariate approaches are crucial for this task. Here, a multivariate approach for quality control in RNA-seq experiments is proposed. This approach uses simple and yet effective well-known statistical methodologies. In particular, Principal Component Analysis was successfully applied over real data to detect and remove outlier samples. In addition, traditional multivariate exploration tools were applied in order to asses several controls that can help to ensure the results quality. Based on differential expression and functional enrichment analysis, here is demonstrated that the information retrieval is significantly enhanced through experiment quality control. Results show that the proposed multivariate approach increases the information obtained from RNA-seq data after outlier samples removal.

  13. Oxidative stress and mitochondrial protein quality control in aging.

    PubMed

    Lionaki, Eirini; Tavernarakis, Nektarios

    2013-10-30

    Mitochondrial protein quality control incorporates an elaborate network of chaperones and proteases that survey the organelle for misfolded or unfolded proteins and toxic aggregates. Repair of misfolded or aggregated protein and proteolytic removal of irreversibly damaged proteins are carried out by the mitochondrial protein quality control system. Initial maturation and folding of the nuclear or mitochondrial-encoded mitochondrial proteins are mediated by processing peptidases and chaperones that interact with the protein translocation machinery. Mitochondrial proteins are subjected to cumulative oxidative damage. Thus, impairment of quality control processes may cause mitochondrial dysfunction. Aging has been associated with a marked decline in the effectiveness of mitochondrial protein quality control. Here, we present an overview of the chaperones and proteases involved in the initial folding and maturation of new, incoming precursor molecules, and the subsequent repair and removal of oxidized aggregated proteins. In addition, we highlight the link between mitochondrial protein quality control mechanisms and the aging process. This article is part of a Special Issue entitled: Posttranslational Protein modifications in biology and Medicine. PMID:23563202

  14. 42 CFR 84.40 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory...

  15. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed...

  16. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or...

  17. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed...

  18. 42 CFR 84.40 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory...

  19. Practicing Quality Control in a Bioanalytical Experiment

    NASA Astrophysics Data System (ADS)

    Marcos, Juliana; Ríos, Angel; Valcárcel, Miguel

    1995-10-01

    The quality of analytical results frequently requires assessment, which has fostered treatment of this subject in a host of chemical books for students. Accordingly, new experiments need to be devised in order to help students adapt to it. This paper presents a straightforward exercise to demonstrate how quality control and the analysis of variance technique are implemented in practice. The exercise also is attractive because the analyte (chlorophyl) is determined in real samples (plants) that students can collect by themselves. In this way, they can realize the significance of sampling and learn how to do it properly.

  20. Quality and Control of Water Vapor Winds

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  1. Laboratory quality control based on risk management.

    PubMed

    Nichols, James H

    2011-01-01

    Risk management is the systematic application of management policies, procedures, and practices to the tasks of analyzing, evaluating, controlling and monitoring risk (the effect of uncertainty on objectives). Clinical laboratories conduct a number of activities that could be considered risk management including verification of performance of new tests, troubleshooting instrument problems and responding to physician complaints. Development of a quality control plan for a laboratory test requires a process map of the testing process with consideration for weak steps in the preanalytic, analytic and postanalytic phases of testing where there is an increased probability of errors. Control processes that either prevent or improve the detection of errors can be implemented at these weak points in the testing process to enhance the overall quality of the test result. This manuscript is based on a presentation at the 2nd International Symposium on Point of Care Testing held at King Faisal Specialist Hospital in Riyadh, Saudi Arabia on October 12-13, 2010. Risk management principles will be reviewed and progress towards adopting a new Clinical and Laboratory Standards Institute Guideline for developing laboratory quality control plans based on risk management will be discussed. PMID:21623049

  2. Effects of waste glass additions on quality of textile sludge-based bricks.

    PubMed

    Rahman, Ari; Urabe, Takeo; Kishimoto, Naoyuki; Mizuhara, Shinji

    2015-01-01

    This research investigated the utilization of textile sludge as a substitute for clay in brick production. The addition of textile sludge to a brick specimen enhanced its pores, thus reducing the quality of the product. However, the addition of waste glass to brick production materials improved the quality of the brick in terms of both compressive strength and water absorption. Maximum compressive strength was observed with the following composition of waste materials: 30% textile sludge, 60% clay and 10% waste glass. The melting of waste glass clogged up pores on the brick, which improved water absorption performance and compressive strength. Moreover, a leaching test on a sludge-based brick to which 10% waste glass did not detect significant heavy metal compounds in leachates, with the product being in conformance with standard regulations. The recycling of textile sludge for brick production, when combined with waste glass additions, may thus be promising in terms of both product quality and environmental aspects. PMID:25812619

  3. Demystifying ratings: How flow control shocks credit quality

    SciTech Connect

    Martin, J.H.

    1998-07-01

    Financial operations of many solid waste systems, waste-to-energy facilities in particular, have been shocked by the lack of congressional, and state and local legislation to resolve the loss of legal flow control. Flow control is a system's legal authority to direct waste into its own facilities. In contrast is economic flow control, where the market factors prevail and waste is brought to a facility based on competitive pricing. The loss of legal flow control threatens solid waste systems and impinges their underlying credit quality. Credit quality is expressed as the bond rating, a statement about the borrowers ability and willingness to repay debt in full and on time. While the courts have identified acceptable alternatives to enable municipal systems to diversity revenues (creating revenue flexibility), such alternatives may not be palatable as they represent additional taxation or fees. The paper highlights how the loss of legal flow control has shocked the operations, management and credit quality of solid waste systems. These shocks have stimulated public and private partnerships in order to facilitate economic flow control. Municipal credit solutions, credit impacts and credit trends are explained to identify how solid waste systems have responded in an operating climate exacerbated by regulatory changes (environmental and accounting) as well as utility deregulations. Analytical considerations are presented for evaluating the credit quality of solid waste bonds.

  4. A system framework of inter-enterprise machining quality control based on fractal theory

    NASA Astrophysics Data System (ADS)

    Zhao, Liping; Qin, Yongtao; Yao, Yiyong; Yan, Peng

    2014-03-01

    In order to meet the quality control requirement of dynamic and complicated product machining processes among enterprises, a system framework of inter-enterprise machining quality control based on fractal was proposed. In this system framework, the fractal-specific characteristic of inter-enterprise machining quality control function was analysed, and the model of inter-enterprise machining quality control was constructed by the nature of fractal structures. Furthermore, the goal-driven strategy of inter-enterprise quality control and the dynamic organisation strategy of inter-enterprise quality improvement were constructed by the characteristic analysis on this model. In addition, the architecture of inter-enterprise machining quality control based on fractal was established by means of Web service. Finally, a case study for application was presented. The result showed that the proposed method was available, and could provide guidance for quality control and support for product reliability in inter-enterprise machining processes.

  5. Protein quality control in the nucleus.

    PubMed

    Jones, Ramon D; Gardner, Richard G

    2016-06-01

    The nucleus is the repository for the eukaryotic cell's genetic blueprint, which must be protected from harm to ensure survival. Multiple quality control (QC) pathways operate in the nucleus to maintain the integrity of the DNA, the fidelity of the DNA code during replication, its transcription into mRNA, and the functional structure of the proteins that are required for DNA maintenance, mRNA transcription, and other important nuclear processes. Although we understand a great deal about DNA and RNA QC mechanisms, we know far less about nuclear protein quality control (PQC) mechanisms despite that fact that many human diseases are causally linked to protein misfolding in the nucleus. In this review, we discuss what is known about nuclear PQC and we highlight new questions that have emerged from recent developments in nuclear PQC studies. PMID:27015023

  6. Quality control analytical methods: strategies to ensure a robust quality-control microbiology program.

    PubMed

    Griffiths, Tricia; Connors, Anne

    2013-01-01

    As the regulatory environment for compounding pharmacies continues to evolve, facilities can take immediate steps to strengthen their quality-control microbiology and environmental monitoring programs. Robust programs that are timely, comprehensive, and effective will minimize risk and help support positive patient outcomes. This article provides a roadmap for putting in place a robust quality-control microbiology program in the face of United States Pharmacopeia Chapter 797 standards, and highlights several technologies for environmental monitoring that support a successful program. PMID:23696174

  7. How intense quality control improves hydraulic fracturing

    SciTech Connect

    Ely, J.W.

    1996-11-01

    Not unlike the subject of Forced Closure, Intense Quality Control is probably misnamed. What actually is discussed in this article is pilot testing of the fracturing fluids actually pumped at in-situ conditions of temperature and shear. Presented here is development of the need for onsite testing, equipment used, shear and viscosity curves from several jobs showing what went wrong that would otherwise not have been known, and a discussion of borate gel fluids.

  8. Can external quality control improve pig AI efficiency?

    PubMed

    Waberski, D; Petrunkina, A M; Töpfer-Petersen, E

    2008-11-01

    External quality control programmes carried out by central laboratories have been long established in human andrology with the aim of enhancing the accuracy and reproducibility of semen assessment. Compared to human, demands on boar semen assessment in AI stations are more complex, with the need both to identify boars with poor ejaculate quality and to monitor individual boar differences for semen storage. Additionally, appropriate assessment serves as a control instrument to ensure the security and efficiency of semen processing. Despite current limitations regarding the ability of sperm assays to estimate the potential fertility of males, it is evident that boar fertility is related to certain conventional semen tests, e.g. sperm morphology. In central studies carried out on stored semen from 11 AI stations, flow cytometric assessment of plasma and acrosome membrane integrity proved to be more sensitive in detecting sperm damage associated with ageing and temperature stress as compared to light microscopy. Membrane integrity of stored semen differed between AI stations indicating significant influences of semen processing on sperm quality. Thus external control of semen quality in reference laboratories may be useful to monitor the efficiency of internal semen quality control in individual AI stations, to identify males with lower semen quality and/or poor response to semen storage, and to verify the precision of sperm counting. The possibility that central laboratories with sufficient resources may be able to identify functionally different responding sperm subpopulations for better estimation of fertility is discussed. Ideally, external quality control schemes for AI stations would comprise application of validated tests with high relevance for fertility (including bacterial status), analysis of semen processing on the AI station, and training courses for laboratory personnel. PMID:18656253

  9. 7 CFR 58.335 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on...

  10. 7 CFR 58.335 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on...

  11. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall...

  12. 7 CFR 58.928 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall...

  13. 7 CFR 58.642 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples...

  14. 7 CFR 58.642 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples...

  15. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations are required for equipment, instruments, and controls? Quality control operations for equipment... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What quality control operations are required...

  16. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 2 2013-04-01 2013-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations are required for equipment, instruments, and controls? Quality control operations for...

  17. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 2 2014-04-01 2014-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations are required for equipment, instruments, and controls? Quality control operations for...

  18. Optimization and quality control of computed radiography

    NASA Astrophysics Data System (ADS)

    Willis, Charles E.; Weiser, John C.; Leckie, Robert G.; Romlein, John R.; Norton, Gary S.

    1994-05-01

    Computed radiography (CR) is a relatively new technique for projection radiography. Few hospitals have CR devices in routine service and only a handful have more than one CR unit. As such, the clinical knowledge base does not yet exist to establish quality control (QC) procedures for CR devices. Without assurance that CR systems are operating within nominal limits, efforts to optimize CR performance are limited in value. A complete CR system includes detector plates that vary in response, cassettes, an electro-optical system for developing the image, computer algorithms for processing the raw image, and a hard copy output device. All of these subsystems are subject to variations in performance that can degrade image quality. Using CR manufacturer documentation, we have defined acceptance protocols for two different Fuji CR devices, the FCR 7000 and the AC1+, and have applied these tests to ten individual machines. We have begun to establish baseline performance measures and to determine measurement frequencies. CR QC is only one component of the overall quality control for totally digital radiology departments.

  19. Additive effects of word frequency and stimulus quality: the influence of trial history and data transformations.

    PubMed

    Balota, David A; Aschenbrenner, Andrew J; Yap, Melvin J

    2013-09-01

    A counterintuitive and theoretically important pattern of results in the visual word recognition literature is that both word frequency and stimulus quality produce large but additive effects in lexical decision performance. The additive nature of these effects has recently been called into question by Masson and Kliegl (in press), who used linear mixed effects modeling to provide evidence that the additive effects were actually being driven by previous trial history. Because Masson and Kliegl also included semantic priming as a factor in their study and recent evidence has shown that semantic priming can moderate the additivity of word frequency and stimulus quality (Scaltritti, Balota, & Peressotti, 2012), we reanalyzed data from 3 published studies to determine if previous trial history moderated the additive pattern when semantic priming was not also manipulated. The results indicated that previous trial history did not influence the joint influence of word frequency and stimulus quality. More important, and independent of Masson and Kliegl's conclusions, we also show how a common transformation used in linear mixed effects analyses to normalize the residuals can systematically alter the way in which two variables combine to influence performance. Specifically, using transformed, rather than raw reaction times, consistently produces more underadditive patterns. PMID:23565779

  20. Mammographic equipment, technique, and quality control

    SciTech Connect

    Friedrich, M.A. )

    1991-08-01

    The most important improvements in mammographic technique were the introduction of single- or double-emulsion high-contrast film-screen combinations for mammography, the use of a specially designed low-kilovoltage Bucky grid to reduce scattered radiation, and the introduction of smaller focal spots to improve imaging geometry. Magnification techniques, especially the spot-film technique, yields clearer delineation of high-contrast microcalcifications. Dedicated mammographic equipment with specially designed x-ray tubes is necessary for modern high-quality mammography. However, in many modern mammographic units, the automatic exposure controller still fails to provide appropriate and constant optical film density over a wide range of tissue thickness and absorption. Extended-cycle processing of single-emulsion mammographic films can yield better image contrast and reduce exposure by up to 30%. Exposure times of less than 1 second are recommended to avoid the unnecessary higher doses caused by longer exposure times and reciprocity law failure. The wide dynamic range in mammography can be reduced by a beam equalization filter, and thus be better adapted to the decreased latitude of modern high-contrast mammographic screen-film systems. Mammographic film reading (detection of subtle microcalcifications) can be facilitated by modern computer evaluation of previously digitized mammograms. Standardization and assurance of image quality have been major challenges in the technical development of mammography. Different technical and anthropomorphic phantoms have been designed to measure and compare practical image quality. Detailed quality control measures have been developed. The benefit of a single or annual screening mammography, calculated in gained life expectancy, by far outweighs the relative risk for radiation-induced breast cancer. 22 references.

  1. Protein quality control in organelles - AAA/FtsH story.

    PubMed

    Janska, Hanna; Kwasniak, Malgorzata; Szczepanowska, Joanna

    2013-02-01

    This review focuses on organellar AAA/FtsH proteases, whose proteolytic and chaperone-like activity is a crucial component of the protein quality control systems of mitochondrial and chloroplast membranes. We compare the AAA/FtsH proteases from yeast, mammals and plants. The nature of the complexes formed by AAA/FtsH proteases and the current view on their involvement in degradation of non-native organellar proteins or assembly of membrane complexes are discussed. Additional functions of AAA proteases not directly connected with protein quality control found in yeast and mammals but not yet in plants are also described shortly. Following an overview of the molecular functions of the AAA/FtsH proteases we discuss physiological consequences of their inactivation in yeast, mammals and plants. The molecular basis of phenotypes associated with inactivation of the AAA/FtsH proteases is not fully understood yet, with the notable exception of those observed in m-AAA protease-deficient yeast cells, which are caused by impaired maturation of mitochondrial ribosomal protein. Finally, examples of cytosolic events affecting protein quality control in mitochondria and chloroplasts are given. This article is part of a Special Issue entitled: Protein Import and Quality Control in Mitochondria and Plastids. PMID:22498346

  2. Influence of Wheat-Milled Products and Their Additive Blends on Pasta Dough Rheological, Microstructure, and Product Quality Characteristics

    PubMed Central

    Dhiraj, B.; Prabhasankar, P.

    2013-01-01

    This study is aimed to assess the suitability of T. aestivum wheat milled products and its combinations with T. durum semolina with additives such as ascorbic acid, vital gluten and HPMC (Hydroxypropyl methyl cellulose) for pasta processing quality characteristics such as pasta dough rheology, microstructure, cooking quality, and sensory evaluation. Rheological studies showed maximum dough stability in Comb1 (T. aestivum wheat flour and semolina). Colour and cooking quality of Comb2 (T. durum semolina and T. aestivum wheat flour) and Comb3 (T. aestivum wheat semolina and T. durum semolina) were comparable with control. Pasting results indicated that T. aestivum semolina gave the lowest onset gelatinization temperature (66.9°C) but the highest peak viscosity (1.053 BU). Starch release was maximum in Comb1 (53.45%) when compared with control (44.9%) as also proved by microstructure studies. Firmness was seen to be slightly high in Comb3 (2.430 N) when compared with control (2.304 N), and sensory evaluations were also in the acceptable range for the same. The present study concludes that Comb3 comprising 50% T. durum semolina and 50% T. aestivum refined wheat flour with additives would be optimal alternate for 100% T. durum semolina for production of financially viable pasta. PMID:26904601

  3. Environmental quality control report. [Semiannual] report, July--December 1988

    SciTech Connect

    Bishop, C.T.

    1989-04-14

    This report presents the details of the Mound Laboratory EPA-NPDES Quality Assurance Program, the DOE Quality Assessment Program Results, Proficiency Environmental Testing Program and Plutonium in Urine Quality Control for 1988.

  4. Protein Quality Control and Degradation in Cardiomyocytes

    PubMed Central

    Wang, Xuejun; Su, Huabo; Ranek, Mark J.

    2008-01-01

    The heart is constantly under stress and cardiomyocytes face enormous challenges to correctly fold nascent polypeptides and keep mature proteins from denaturing. To meet the challenge, cardiomyocytes have developed multi-layered protein quality control (PQC) mechanisms which are carried out primarily by chaperones and ubiquitin-proteasome system mediated proteolysis. Autophagy may also participate in PQC in cardiomyocytes, especially under pathological conditions. Cardiac PQC often becomes inadequate in heart disease, which may play an important role in the development of congestive heart failure. PMID:18495153

  5. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    PubMed Central

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  6. Additives and method for controlling clathrate hydrates in fluid systems

    DOEpatents

    Sloan, E.D. Jr.; Christiansen, R.L.; Lederhos, J.P.; Long, J.P.; Panchalingam, V.; Du, Y.; Sum, A.K.W.

    1997-06-17

    Discussed is a process for preventing clathrate hydrate masses from detrimentally impeding the possible flow of a fluid susceptible to clathrate hydrate formation. The process is particularly useful in the natural gas and petroleum production, transportation and processing industry where gas hydrate formation can cause serious problems. Additives preferably contain one or more five member, six member and/or seven member cyclic chemical groupings. Additives include polymers having lactam rings. Additives can also contain polyelectrolytes that are believed to improve conformance of polymer additives through steric hindrance and/or charge repulsion. Also, polymers having an amide on which a C{sub 1}-C{sub 4} group is attached to the nitrogen and/or the carbonyl carbon of the amide may be used alone, or in combination with ring-containing polymers for enhanced effectiveness. Polymers having at least some repeating units representative of polymerizing at least one of an oxazoline, an N-substituted acrylamide and an N-vinyl alkyl amide are preferred.

  7. Additives and method for controlling clathrate hydrates in fluid systems

    DOEpatents

    Sloan, Jr., Earle Dendy; Christiansen, Richard Lee; Lederhos, Joseph P.; Long, Jin Ping; Panchalingam, Vaithilingam; Du, Yahe; Sum, Amadeu Kun Wan

    1997-01-01

    Discussed is a process for preventing clathrate hydrate masses from detrimentally impeding the possible flow of a fluid susceptible to clathrate hydrate formation. The process is particularly useful in the natural gas and petroleum production, transportation and processing industry where gas hydrate formation can cause serious problems. Additives preferably contain one or more five member, six member and/or seven member cyclic chemical groupings. Additives include polymers having lactam rings. Additives can also contain polyelectrolytes that are believed to improve conformance of polymer additives through steric hinderance and/or charge repulsion. Also, polymers having an amide on which a C.sub.1 -C.sub.4 group is attached to the nitrogen and/or the carbonyl carbon of the amide may be used alone, or in combination with ring-containing polymers for enhanced effectiveness. Polymers having at least some repeating units representative of polymerizing at least one of an oxazoline, an N-substituted acrylamide and an N-vinyl alkyl amide are preferred.

  8. Microstructure-controllable Laser Additive Manufacturing Process for Metal Products

    NASA Astrophysics Data System (ADS)

    Huang, Wei-Chin; Chuang, Chuan-Sheng; Lin, Ching-Chih; Wu, Chih-Hsien; Lin, De-Yau; Liu, Sung-Ho; Tseng, Wen-Peng; Horng, Ji-Bin

    Controlling the cooling rate of alloy during solidification is the most commonly used method for varying the material microstructure. However, the cooling rate of selective laser melting (SLM) production is constrained by the optimal parameter settings for a dense product. This study proposes a method for forming metal products via the SLM process with electromagnetic vibrations. The electromagnetic vibrations change the solidification process for a given set of SLM parameters, allowing the microstructure to be varied via magnetic flux density. This proposed method can be used for creating microstructure-controllable bio-implant products with complex shapes.

  9. 7 CFR 58.141 - Alternate quality control program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by...

  10. 7 CFR 58.141 - Alternate quality control program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by...

  11. Antimisting kerosene: Base fuel effects, blending and quality control techniques

    NASA Technical Reports Server (NTRS)

    Yavrouian, A. H.; Ernest, J.; Sarohia, V.

    1984-01-01

    The problems associated with blending of the AMK additive with Jet A, and the base fuel effects on AMK properties are addressed. The results from the evaluation of some of the quality control techniques for AMK are presented. The principal conclusions of this investigation are: significant compositional differences for base fuel (Jet A) within the ASTM specification DI655; higher aromatic content of the base fuel was found to be beneficial for the polymer dissolution at ambient (20 C) temperature; using static mixer technology, the antimisting additive (FM-9) is in-line blended with Jet A, producing AMK which has adequate fire-protection properties 15 to 20 minutes after blending; degradability of freshly blended and equilibrated AMK indicated that maximum degradability is reached after adequate fire protection is obtained; the results of AMK degradability as measured by filter ratio, confirmed previous RAE data that power requirements to decade freshly blended AMK are significantly higher than equilibrated AMK; blending of the additive by using FM-9 concentrate in Jet A produces equilibrated AMK almost instantly; nephelometry offers a simple continuous monitoring capability and is used as a real time quality control device for AMK; and trajectory (jet thurst) and pressure drop tests are useful laboratory techniques for evaluating AMK quality.

  12. Fluid loss control additives for oil well cementing compositions

    SciTech Connect

    Crema, S.C.; Kucera, C.H.; Konrad, G.; Hartmann, H.

    1993-07-20

    A cementing composition is described useful in cementing oil, gas and water wells comprising: (a) water; (b) hydraulic cement; and (c) a fluid loss additive in an amount effective to reduce fluid loss, to below 100 cc/30 min said fluid loss additive comprised of a blend of (i) a copolymer of acrylamide and vinyl imidazole, in a weight percent ratio of from about 95:5 to 5:95, acryamide to vinyl imidazole said copolymer having a molecular weight range of from about 10,000 to 3,000,000, and (ii) a copolymer of vinyl pyrrolidone and sodium salt of sulfonate in a weight percent ratio of 80:20 to 20:80; the ratio of copolymer (i) to copolymer (ii) being in the range of 20:80 to 80:20.

  13. Direct laser additive fabrication system with image feedback control

    DOEpatents

    Griffith, Michelle L.; Hofmeister, William H.; Knorovsky, Gerald A.; MacCallum, Danny O.; Schlienger, M. Eric; Smugeresky, John E.

    2002-01-01

    A closed-loop, feedback-controlled direct laser fabrication system is disclosed. The feedback refers to the actual growth conditions obtained by real-time analysis of thermal radiation images. The resulting system can fabricate components with severalfold improvement in dimensional tolerances and surface finish.

  14. Image quality evaluation and control of computer-generated holograms

    NASA Astrophysics Data System (ADS)

    Yoshikawa, Hiroshi; Yamaguchi, Takeshi; Uetake, Hiroki

    2016-03-01

    Image quality of the computer-generated holograms are usually evaluated subjectively. For example, the re- constructed image from the hologram is compared with other holograms, or evaluated by the double-stimulus impairment scale method to compare with the original image. This paper proposes an objective image quality evaluation of a computer-generated hologram by evaluating both diffraction efficiency and peak signal-to-noise ratio. Theory and numerical experimental results are shown on Fourier transform transmission hologram of both amplitude and phase modulation. Results without the optimized random phase show that the amplitude transmission hologram gives better peak signal-to noise ratio, but the phase transmission hologram provides about 10 times higher diffraction efficiency to the amplitude type. As an optimized phase hologram, Kinoform is evaluated. In addition, we investigate to control image quality by non-linear operation.

  15. Fouling control in seawater by on-line acid addition

    SciTech Connect

    Salvago, G.; Taccani, G.; Polimeni, R.; Fumagalli, G.; Picenoni, D.

    1996-11-01

    An experimental plant was set up containing once-through test lines supplied with seawater. The pH level of the seawater was maintained at 6.3 by the acids addition. Heat exchange monitoring equipment and channels exposing different metal specimens were installed on each of the lines. Observation by microscope and EDS analyses were carried out both on the specimen surfaces and on the cross section of the fouling after fracturing in liquid N{sub 2}. The results obtained show that: fouling must not be confused with its effects or simply with its biological components; acidifying seawater can prevent the resistance to heat exchange from increasing without impeding its biological activity. Observation by microscope of the fouling cross sections showed that in untreated seawater the foulings on stainless steel were composed of a continuous compact layer, covered by disorderly clusters. These compact layers were found to contain high quantities of corrosion products of the metals. Elements typical of corrosion products of ferrous materials (Fe, Mn) were also found on Pt, copper alloys and plastic materials. The addition of HCl or H{sub 2}SO{sub 4} to the seawater, to bring it to pH 6.3, reduces the amount of fouling adhering to the surfaces, prevents the development of the continuous layer containing iron and prevents significant increases in heat exchange resistance. The addition of CO{sub 2} can encourage the development of incoherent fibrous material with high Si content and low Fe content which is of little impediment to heat exchange. The addition of lactic acid can encourage both the abnormal development of biomass and the formation of several, separate, layers on stainless steel surfaces.

  16. Quality Control, Quality Assurance, and Quality Improvement-What is the Difference and Why Should Compounding Pharmacies Care?

    PubMed

    Cabaleiro, Joe

    2009-01-01

    This article provides scenarios of three different pharmacies in the areas of quality control, quality assurance, and quality improvement. The scenarios show the importance that each pharmacy placed on a problem of dented capsules and the potential impact that an unresolved problem can have on a compounding pharmacy's business. Although this article focuses on one particular procedure, the purpose of th article is to help pharmacists understand the differences between quality control, quality assurance, and quality improvement. PMID:23966522

  17. Data quality control of ADSN Broadband stations

    NASA Astrophysics Data System (ADS)

    Alili, Azouaou; Yelles-chaouche, Abd el karim; Allili, Toufik; Messemen, Walid

    2014-05-01

    In this work we present the analysis of continuous waveform of the Algerian digital seismic network recorded during five years from 2008 to 2013 for twenty broadband stations using the power spectral densities (PSDs) and their corresponding probability density functions (PDFs) algorithm of McNamara, and Buland (2004). ADSN Broadband stations data quality is one main concern and interest of ADSN technical team. Indeed, the quality of the data from broadband stations is continuously controlled in quasi-realtime using "PQLX" (Pascal Quick Look eXtended) software to compute the PDFs and PSDs during the operation of the stations at different frequency range. At each station the level of noise is shown, which we can see diurnal and seasonal variation. From the data analysis, most of the ADSN Broadband stations display good records in the several frequency domains in relation with their site installation. However some of stations near the urban areas could present some noisy disturbances. This led sometimes to generate some ghost events. In the low frequency, some stations could be still influenced by the temperature variations. This long period of records from 2008 to 2013, led us to analyze and control the several stations year by year taking into account the seasons and to know about their work during five years. This analysis is also very important to improve in the future quality of station installation and choose the optimal station design in aim to reduce cultural noise and large fluctuation of temperature and pressure. Key words: PQLX, PDFs, PSDs, Broad Band

  18. New automated quality control of phenological data in Switzerland

    NASA Astrophysics Data System (ADS)

    Pietragalla, Barbara; Knechtl, Valentin; Sigg, Christian; Clot, Bernard

    2016-04-01

    Phenological observations are considered important indicators of climate change. Therefore, reliable data is a crucial requirement. In 2015 MeteoSwiss has developed an automated quality control for phenological data that runs weekly to check the incoming data. The aim is to detect implausible data. The implausible values are further examined manually. The Swiss Phenology Network, initiated in 1951, consists of about 160 stations observing 69 phenological parameters from 26 species. In 2015 the network generated 6475 values of onset dates. For the recognition of implausible data, linear models are used. For each of the phenological parameters that should be verified the most predictive parameters have been determined in correlation tests. Up to four different parameters are used as predictive variables. The three main predictive parameters are the mean onset date of the respective phenophase (at that specific station), the cumulated daily mean temperature and an additional phenological parameter with the highest correlation. The model uses a defined sequence of steps, which can handle the absence of additional predictive phenological parameters (in case that in spring time some of these phenophases are not yet available). The model output is a predicted date which can be compared with the observed onset date that undergoes the quality control. The magnitude of this deviation decides, if a value is regarded as potentially problematic. An additional quality check examines if the natural sequence of the phenophases within a species is correct, for example that the date of the "begin of flowering" occurs before the "full flowering". The output of the automated quality control is a list of flagged values of potentially erroneous data that have to be examined manually in a second step. To facilitate the expert's decision whether a value is correct or wrong, a report is automatically created, showing the data graphically and in comparison with other stations of the same

  19. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production,...

  20. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production,...

  1. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production,...

  2. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable...

  3. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable...

  4. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production,...

  5. Porosity Measurements and Analysis for Metal Additive Manufacturing Process Control

    PubMed Central

    Slotwinski, John A; Garboczi, Edward J; Hebenstreit, Keith M

    2014-01-01

    Additive manufacturing techniques can produce complex, high-value metal parts, with potential applications as critical metal components such as those found in aerospace engines and as customized biomedical implants. Material porosity in these parts is undesirable for aerospace parts - since porosity could lead to premature failure - and desirable for some biomedical implants - since surface-breaking pores allows for better integration with biological tissue. Changes in a part’s porosity during an additive manufacturing build may also be an indication of an undesired change in the build process. Here, we present efforts to develop an ultrasonic sensor for monitoring changes in the porosity in metal parts during fabrication on a metal powder bed fusion system. The development of well-characterized reference samples, measurements of the porosity of these samples with multiple techniques, and correlation of ultrasonic measurements with the degree of porosity are presented. A proposed sensor design, measurement strategy, and future experimental plans on a metal powder bed fusion system are also presented. PMID:26601041

  6. Porosity Measurements and Analysis for Metal Additive Manufacturing Process Control.

    PubMed

    Slotwinski, John A; Garboczi, Edward J; Hebenstreit, Keith M

    2014-01-01

    Additive manufacturing techniques can produce complex, high-value metal parts, with potential applications as critical metal components such as those found in aerospace engines and as customized biomedical implants. Material porosity in these parts is undesirable for aerospace parts - since porosity could lead to premature failure - and desirable for some biomedical implants - since surface-breaking pores allows for better integration with biological tissue. Changes in a part's porosity during an additive manufacturing build may also be an indication of an undesired change in the build process. Here, we present efforts to develop an ultrasonic sensor for monitoring changes in the porosity in metal parts during fabrication on a metal powder bed fusion system. The development of well-characterized reference samples, measurements of the porosity of these samples with multiple techniques, and correlation of ultrasonic measurements with the degree of porosity are presented. A proposed sensor design, measurement strategy, and future experimental plans on a metal powder bed fusion system are also presented. PMID:26601041

  7. Fermentation Quality of Ensiled Water Hyacinth (Eichhornia crassipes) as Affected by Additives

    PubMed Central

    Tham, Ho Thanh; Van Man, Ngo; Pauly, Thomas

    2013-01-01

    A lab-scale ensiling study was carried out to investigate the fermentation quality of water hyacinth (WH) supplemented with molasses, rice bran, as an absorbent, and an inoculant in the form of fermented vegetable juice and their combinations. After wilting the water hyacinths for 7 h to a dry matter (DM) content of 240 to 250 g/kg, the following treatments were applied: i) Control (C), WH only; ii) WH with sugarcane molasses at 40 g/kg WH (CM); iii) WH inoculated with fermented vegetable juice at 10 ml/kg WH (CI); iv) CM and CI (CMI) combined; v) WH with 150 g rice bran/kg WH (CA); vi) CA and CI combined (CAI); vii) CA and CM combined (CAM); and viii) CA, CM and CI combined (CAMI). After application of additives, the differently treated forages were mixed and ensiled in triplicates in 1,500-ml polyethylene jars. After ensiling for 3 d, pH values in all treatments, except C and CI, had decreased to approximately 4.0 and remained low till 14 d. After 56 d, pH had increased between 0.4 to 0.9 pH-units compared to those at 14 d. The ammonia nitrogen (NH3-N) concentration ranged from an acceptable level in treatment CM (8 g/kg N) to a high NH3-N value in treatment CMI (16 g/kg N). Lactic acid formation was higher in CI than in all other treatments. Butyric acid contents, which indicate badly fermented silages, were low in all silages (<2 g/kg DM). There were two-way interactions (p-values from <0.001 to 0.045) for almost all fermentation end-products and pH, except for the molasses×inoculant interaction on NH3-N (p = 0.26). Significant 3-way interactions were found on all observed variables except for weight losses of silages. It is concluded that conserving wilted WH as silage for ruminants may be improved by the addition of molasses or rice bran. PMID:25049776

  8. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Operation and Maintenance Requirements § 75.21 Quality assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner...

  9. Part height control of laser metal additive manufacturing process

    NASA Astrophysics Data System (ADS)

    Pan, Yu-Herng

    Laser Metal Deposition (LMD) has been used to not only make but also repair damaged parts in a layer-by-layer fashion. Parts made in this manner may produce less waste than those made through conventional machining processes. However, a common issue of LMD involves controlling the deposition's layer thickness. Accuracy is important, and as it increases, both the time required to produce the part and the material wasted during the material removal process (e.g., milling, lathe) decrease. The deposition rate is affected by multiple parameters, such as the powder feed rate, laser input power, axis feed rate, material type, and part design, the values of each of which may change during the LMD process. Using a mathematical model to build a generic equation that predicts the deposition's layer thickness is difficult due to these complex parameters. In this thesis, we propose a simple method that utilizes a single device. This device uses a pyrometer to monitor the current build height, thereby allowing the layer thickness to be controlled during the LMD process. This method also helps the LMD system to build parts even with complex parameters and to increase material efficiency.

  10. [Evaluating an internal quality control procedure: application to multidimensional control].

    PubMed

    Marquis, P; Masseyeff, R

    2002-01-01

    Internal quality control keeps in constant evolution in the industrial world. Introducing in clinical chemistry new QC methods derived from the industrial practice raises the point of the means for their evaluation. The main evaluation criteria are discussed in this paper. The importance of ARL (average run length) as a key-criterion of the efficiency of a quality control procedure is stressed. These principles were applied to the multivariate approach of multilevel control with the Hotelling's T2. This method led to a better detection of random errors than the independently managed conventional Shewhart (Levey- Jennings) charts. Applied to systematic errors, both methods gave similar results with a certain lack of sensitivity. However the multivariate method can be sensitised using EWMA (exponentially weighted moving average), a method specific for improved bias detection. EWMA efficiency outperforms that of the older systems of rules. Moreover, in any kind of error, multivariate approach secures a well-defined false rejection rate, whereas this rate is dependant on unknown inter-level correlation coefficients in conventional QC. PMID:12368148

  11. Condensate kicks pose additional problems for deep well control

    SciTech Connect

    Szczepanski, R.; Edmonds, B.; Yerlett, T.K.; Brown, N.P.; Hamilton, T.A.P.

    1996-06-17

    Modeling condensate and gas kicks in a deep North Sea well helps drillers understand what to expect after prompt kick detection in a straight-forward kick circulation program with competent choke handling. Concerns have been raised in the industry that as a condensate kick is taken and subsequently circulated out of the well, unexpected surface indications may be present. Blowouts, resulting from uncontrolled kicks, could be particularly hazardous for condensate fields as these are often high-pressure, high-temperature operations. A deeper understanding of the differences, and similarities, between gas and condensate kicks has resulted from an investigation by Infochem Computer Services Ltd., funded by the UK Health and Safety Executive (HSE). This study has led to an assessment of the practical significance of any differences for the personnel involved in well control.

  12. Intelligent process quality control system into supply chain

    NASA Astrophysics Data System (ADS)

    Wang, Shijie; Jiang, Xingyu; Wang, Yingchun

    2010-01-01

    To cope with the challenges of monitoring dynamic and variable quality variation into supply chain, diagnosing the abnormal variation at the right moment, is a difficult problem that a enterprise in supply chain faces in process quality control. An intelligent process quality control mode into supply chain, which integrated quality prevention, analysis, diagnosis and adjustment, and corresponding functional modules and framework were all put forward. This mode dealt mainly with constructing and running intelligent quality control system, such as the theory of similarity manufacturing, Statistical Process Control (SPC), neural network. Furthermore, some key enabling technologies were studied in detail, including process quality analysis on-line based on similarity process and process quality diagnosis based on Elman and expert system of process quality adjustment. It is basis of realizing network, intelligent and automatic process quality control into supply.

  13. Intelligent process quality control system into supply chain

    NASA Astrophysics Data System (ADS)

    Wang, Shijie; Jiang, Xingyu; Wang, Yingchun

    2009-12-01

    To cope with the challenges of monitoring dynamic and variable quality variation into supply chain, diagnosing the abnormal variation at the right moment, is a difficult problem that a enterprise in supply chain faces in process quality control. An intelligent process quality control mode into supply chain, which integrated quality prevention, analysis, diagnosis and adjustment, and corresponding functional modules and framework were all put forward. This mode dealt mainly with constructing and running intelligent quality control system, such as the theory of similarity manufacturing, Statistical Process Control (SPC), neural network. Furthermore, some key enabling technologies were studied in detail, including process quality analysis on-line based on similarity process and process quality diagnosis based on Elman and expert system of process quality adjustment. It is basis of realizing network, intelligent and automatic process quality control into supply.

  14. Predicting the effects of nanoscale cerium additives in diesel fuel on regional-scale air quality.

    PubMed

    Erdakos, Garnet B; Bhave, Prakash V; Pouliot, George A; Simon, Heather; Mathur, Rohit

    2014-11-01

    Diesel vehicles are a major source of air pollutant emissions. Fuel additives containing nanoparticulate cerium (nCe) are currently being used in some diesel vehicles to improve fuel efficiency. These fuel additives also reduce fine particulate matter (PM2.5) emissions and alter the emissions of carbon monoxide (CO), nitrogen oxides (NOx), and hydrocarbon (HC) species, including several hazardous air pollutants (HAPs). To predict their net effect on regional air quality, we review the emissions literature and develop a multipollutant inventory for a hypothetical scenario in which nCe additives are used in all on-road and nonroad diesel vehicles. We apply the Community Multiscale Air Quality (CMAQ) model to a domain covering the eastern U.S. for a summer and a winter period. Model calculations suggest modest decreases of average PM2.5 concentrations and relatively larger decreases in particulate elemental carbon. The nCe additives also have an effect on 8 h maximum ozone in summer. Variable effects on HAPs are predicted. The total U.S. emissions of fine-particulate cerium are estimated to increase 25-fold and result in elevated levels of airborne cerium (up to 22 ng/m3), which might adversely impact human health and the environment. PMID:25271762

  15. Effects of Ripening Duration and Rosemary Powder Addition on Salchichon Modified Sausage Quality

    PubMed Central

    Jung, Jong-Hyun; Shim, Kwan-Seob; Shin, Daekeun

    2015-01-01

    The ripening durations and ingredients for the Salchichon sausages were modified to increase pork rear leg consumption by Korean consumers. The salchichon, a ripened pork sausage, was produced to evaluate the efficacy of two different ripening durations with and without rosemary powder on salchichon sausage quality, and the treatments were: i) 45 days of ripening without rosemary, ii) 60 days of ripening without rosemary, iii) 45 days of ripening with 0.05% rosemary, and iv) 60 days of ripening with 0.05% rosemary. Significant differences were observed in both moisture and fat content for ripening durations, with the highest moisture and least fat content observed in salchichon modified sausage (SMS) ripened for 45 days. Ripening duration and rosemary addition appeared to influence water activity (aw) of salchichon sausages. The aw of SMS ripened for 45 days was 0.80, whereas the other had aw values <0.80. Lactic acid bacteria were predominant, as Korean traditional fermented red pepper paste was added to sausages; however, the Bacillus cereus population was significantly affected by rosemary powder addition. Chewiness and gumminess decreased significantly due to the addition of rosemary powder compared to SMS without rosemary powder, and both 45 days of ripening and rosemary powder addition influenced the hardness of SMS. In conclusion, ripening duration of SMS for 45 days in the presence of rosemary powder provided superior SMS quality with an economical ripening duration compared to that of ripening with rosemary powder or ripening for 60 days. PMID:25924959

  16. Roles of additives and surface control in slurry atomization

    SciTech Connect

    Tsai, S.C.

    1992-01-01

    This project studies the rheology and airblast atomization of micronized coal slurries. Its major objectives are (1) to promote further understanding of the mechanisms and the roles of additives in airblast atomization of coal water slurry (CWS), and (2) to investigate the impacts of coal particle surface properties and interparticle forces on CWS rheology. We have found that the flow behavior index (n) of a suspension (or slurry) is determined by the relative importance of the interparticle van der Waals attraction and the interparticle electrostatic repulsion. The interparticle attraction, measured by the Hamaker constant scaled to the thermal energy at 25[degrees]C (A/kT), causes particle aggregation, which breaks down at high shear rates, and thus leads to slurry pseudoplastic behavior (n< 1). At a constant particle volume fraction and surface charge density (qualitatively measured by the zeta potential in deionized water), n decreases linearly as A/kT increases. The relative viscosity of the pseudoplastic suspension with respect to that of the suspending liquid is found to be independent of particle density and correlate well with the particle Peclet number which equals the particle diffusional relaxation time multiplied by shear rate. Specifically, the relative viscosities of the pseudoplastic glycerol/water coal slurry and the ethylene glycol/glycerol sand slurry, at same volume fractions as well as similar particle size distributions and liquid viscosities, as functions of the particle Peclet number fall along the same line.

  17. Tools for quality control of fingerprint databases

    NASA Astrophysics Data System (ADS)

    Swann, B. Scott; Libert, John M.; Lepley, Margaret A.

    2010-04-01

    Integrity of fingerprint data is essential to biometric and forensic applications. Accordingly, the FBI's Criminal Justice Information Services (CJIS) Division has sponsored development of software tools to facilitate quality control functions relative to maintaining its fingerprint data assets inherent to the Integrated Automated Fingerprint Identification System (IAFIS) and Next Generation Identification (NGI). This paper provides an introduction of two such tools. The first FBI-sponsored tool was developed by the National Institute of Standards and Technology (NIST) and examines and detects the spectral signature of the ridge-flow structure characteristic of friction ridge skin. The Spectral Image Validation/Verification (SIVV) utility differentiates fingerprints from non-fingerprints, including blank frames or segmentation failures erroneously included in data; provides a "first look" at image quality; and can identify anomalies in sample rates of scanned images. The SIVV utility might detect errors in individual 10-print fingerprints inaccurately segmented from the flat, multi-finger image acquired by one of the automated collection systems increasing in availability and usage. In such cases, the lost fingerprint can be recovered by re-segmentation from the now compressed multi-finger image record. The second FBI-sponsored tool, CropCoeff was developed by MITRE and thoroughly tested via NIST. CropCoeff enables cropping of the replacement single print directly from the compressed data file, thus avoiding decompression and recompression of images that might degrade fingerprint features necessary for matching.

  18. Quality control in the "flash" process.

    PubMed

    1985-03-01

    This article has briefly discussed the three basic types of sterilization monitoring systems--mechanical, chemical, and biological. Mechanical indicators help tell you that the sterilizer is working. Chemical indicators provide you with immediate information in each "flash" load that the conditions necessary for steam sterilization were present. Biological indicators tell you that microorganisms were killed. For maximum assurance that the conditions necessary for steam sterilization are present and that non-sterile instruments are not inadvertently used, each "flash" sterilizer should be monitored daily with biological indicators and each "flash" load with chemical indicators. This quality control monitoring program should give the O.R. staff confidence that their "flash" sterilization process is working. PMID:10271096

  19. Regiodivergent Addition of Phenols to Allylic Oxides: Control of 1,2 and 1,4-Additions for Cyclitol Synthesis**

    PubMed Central

    Moschitto, Matthew J.; Vaccarello, David N.; Lewis, Chad A.

    2015-01-01

    Control of 1,2- and 1,4-addition of substituted phenols to allylic oxides is achieved by intercepting palladium π-allyl complexes. The interconversion of palladium complexes results in the total synthesis of MK7607, cyathiformine B type, streptol, and a new cyclitol. PMID:25533617

  20. A concatenated coded modulation scheme for error control (addition 2)

    NASA Technical Reports Server (NTRS)

    Lin, Shu

    1988-01-01

    A concatenated coded modulation scheme for error control in data communications is described. The scheme is achieved by concatenating a Reed-Solomon outer code and a bandwidth efficient block inner code for M-ary PSK modulation. Error performance of the scheme is analyzed for an AWGN channel. It is shown that extremely high reliability can be attained by using a simple M-ary PSK modulation inner code and a relatively powerful Reed-Solomon outer code. Furthermore, if an inner code of high effective rate is used, the bandwidth expansion required by the scheme due to coding will be greatly reduced. The proposed scheme is particularly effective for high-speed satellite communications for large file transfer where high reliability is required. This paper also presents a simple method for constructing block codes for M-ary PSK modulation. Some short M-ary PSK codes with good minimum squared Euclidean distance are constructed. These codes have trellis structure and hence can be decoded with a soft-decision Viterbi decoding algorithm. Furthermore, some of these codes are phase invariant under multiples of 45 deg rotation.

  1. Influence of defatted soy flour addition on the quality and stability of pretzel type product.

    PubMed

    Naik, Haroon Rashid; Sekhon, K S

    2014-03-01

    Effect of soya flour addition to 70% extraction bread wheat flour (PBW-343) at (0, 5, 10, 20 & 30%) was investigated for physico-chemical, dough handling and pretzel making properties. Results revealed that with increasing DSF addition, farinogram characteristics; water absorption, arrival time, dough development time and dough stability increased while mixing tolerance index and degree of softening decreased. Amylogram characteristics gelatinization temperature, peak viscosity, peak temperature and viscosity at 95 °C decreased with extended rate of DSF addition. Pretzels developed with different levels of DSF addition observed decrease in moisture, fat, non reducing sugars and starch where as ash, protein, reducing and total sugars increased compared to control. Calories calculated from proximate composition showed lower values than control due to high protein and low fat soy flour addition. Minerals increased significantly with increased levels of defatted soy flour addition. Organoleptic evaluation revealed that 5% level of soy flour blended pretzels were found best with respect to texture, colour and flavor on the basis of mean acceptability scores. Pretzels recorded shelf life of 90 days in laminated pouches irrespective of the level of DSF addition. PMID:24587534

  2. Effects of the Addition of Ecklonia cava Powder on the Selected Physicochemical and Sensory Quality of White Pan Bread.

    PubMed

    Lee, Jun Ho; Choi, Dong Won

    2013-12-01

    Physicochemical properties and consumer perception of white pan bread as influenced by the addition of Ecklonia cava powder (ECP) were investigated. Freeze-dried Ecklonia cava were ground, sieved through a laboratory sieve and a fraction with particles less than 250 μm was used. Amount of ECP added (0~3%) to the bread was found to affect the bread quality significantly (P<0.05). pH, bread height, and volume of the control was significantly higher than others (P<0.05) and decreased significantly (P<0.05) with the addition of ECP. Moisture content showed no significant differences (P>0.05). There were distinctive color changes with the addition of the powder: L*- and a*-values decreased but b*-value increased significantly (P<0.05). The hardness of bread was found to increase but both cohesiveness and springiness showed a reverse trend with the addition of the powder. Consumer acceptance test indicated that ECP content 1% on wheat flour could be the recommended supplementation level for the consumers without sacrificing sensory quality. PMID:24551832

  3. The MAP3S network data and quality control summary for 1985

    SciTech Connect

    Dana, M.T.

    1988-02-01

    This report, the ninth in a series documenting results from the MAP3S Precipitation Chemistry Network, contains a statistical summary of daily precipitation chemistry data from the nine-site network in the eastern United States, both for the year 1985 alone and for the period 1977 through 1985. In addition, a report on quality control and external quality assurance activities is included, which updates the 1980 quality control report.

  4. Chapter 5: Quality assurance/quality control in stormwater sampling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Sampling the quality of stormwater presents unique challenges because stormwater flow is relatively short-lived with drastic variability. Furthermore, storm events often occur with little advance warning, outside conventional work hours, and under adverse weather conditions. Therefore, most stormwat...

  5. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control...

  6. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control...

  7. Effect of additives and steaming on quality of air dried noodles.

    PubMed

    Gatade, Abhijeet Arun; Sahoo, Akshaya Kumar

    2015-12-01

    Texture is the most important property for consumer acceptance in cooked noodles. The air dried noodles are known to have higher cooking loss and cooking time, to that of instant fried noodles. But the fat content of instant fried noodles is more. In the present work attempts were made to optimize the moisture content so as to obtain a smooth dough for extruded noodle preparation and develop air dried noodles of low fat content with lesser cooking loss and cooking time. To meet the objectives, the effect of various additives and steaming treatment on cooking quality, sensory attributes, textural properties and microstructure of noodles were studied. Dough prepared by addition of 40 ml water to 100 g flour resulted into formation of a soft dough, leading to production of noodles of improved surface smoothness and maximum yield. The use of additives (5 g oil, 0.2 g guar gum, 2 g gluten and 1 ml of 1 % kansui solution for 100 g of flour) and steaming treatment showed significant effect on noodles quality, with respect to cooking characteristics, sensory attributes and textural properties. The microstructure images justified the positive correlation between the effects of ingredients with steaming and quality parameters of noodles. Air dried noodles with reduced cooking loss (~50 % reduction) with marginal reduction in cooking time was developed, which were having similar characteristics to that of instant fried noodles. Compared to the instant fried noodle, the prepared air dried noodle was having substantially reduced fat content (~70 % reduction). Thus the present study will be useful for guiding extrusion processes for production of air dried noodles having less cooking time and low fat content. PMID:26604421

  8. Effect of Addition of Allium hookeri on the Quality of Fermented Sausage with Meat from Sulfur Fed Pigs during Ripening

    PubMed Central

    Lim, Ki-Won

    2014-01-01

    The effect of the addition of Allium hookeri on the quality of fermented sausage made with meat from sulfur fed pigs was examined, throughout a 60 d ripening period. There were two treatments in animal management: normal feed fed pigs, and sulfur fed pigs given 0.3% sulfur mixed normal feed. Fermented sausage manufactured with meat from normal feed fed pigs, and with meat from sulfur fed pigs, and 1% A. hookeri-containing fermented sausage processed with meat from sulfur fed pigs, were determined at 1 d, 15 d, 30 d, and 60 d. The meat qualities in fermented sausage were measured by DPPH radical scavenging activity (DPPH), ABTS+ radical scavenging activity (ABTS+), total phenolic acids, and total flavonoid contents. Fermented sausage made from pigs that had been fed with 0.3% sulfur was protected from oxidation by reduced free radical, as shown by the significant increase in DPPH and ABTS+ values, compared with fermented sausage made from normal feed fed pigs (p<0.05). A. hookeri-added fermented sausage with sulfur fed pork was shown to increase the values in DPPH, ABTS+, total phenolic acid, and total flavonoid contents, by comparison with both the control sausage, and sausage with sulfur fed pork, at 60 d. These results suggest that A. hookeri in meat from sulfur fed pigs could be a source of natural addition, to increase quality in the food industry. PMID:26761166

  9. Quality-controlled Subject Gateways: Definitions, Typologies, Empirical Overview.

    ERIC Educational Resources Information Center

    Koch, Traugott

    2000-01-01

    "Quality-controlled subject gateways" are Internet services which apply quality measures to support systematic resource discovery. A main goal is to provide high quality subject access through indexing resources using controlled vocabularies and by offering a deep classification structure for advanced searching and browsing. Provides an empirical…

  10. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING SHORT-CIRCUIT...) Each quality control plan shall contain provisions for the management of quality, including: (1... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Quality control plans; contents. 28.31...

  11. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING SHORT-CIRCUIT...) Each quality control plan shall contain provisions for the management of quality, including: (1... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; contents. 28.31...

  12. 75 FR 41874 - Quality Control for Rental Assistance Subsidy Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-19

    ... URBAN DEVELOPMENT Quality Control for Rental Assistance Subsidy Determinations AGENCY: Office of the... agency's estimate of the burden of the proposed collection of information; (3) Enhance the quality.... This notice also lists the following information: Title of Proposal: Quality Control for...

  13. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality...

  14. 14 CFR 21.147 - Changes in quality control system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality...

  15. Quality Assurance and Quality Control in Point-of-Care Testing.

    PubMed

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. PMID:27451043

  16. Internal quality control in point-of-care testing: where's the evidence?

    PubMed

    Holt, Helen; Freedman, Danielle B

    2016-03-01

    ISO 22870 standards require protocols for performance of internal quality control for all point-of-care testing devices and training of users in its theory and practice. However, the unique setting of point-of-care testing (i.e. processes conducted by non-scientific users) means that laboratory internal quality control programmes do not easily translate to point-of-care testing. In addition, while the evidence base for internal quality control within the laboratory has been increasing, the equivalent literature surrounding point-of-care testing is very limited. This has led to wide variation in what is considered acceptable practice for internal quality control at the point of care. Indeed, it has been demonstrated that internal quality control is an area of deficiency in point-of-care testing. Internal quality control protocols used at point-of-care testing should be defined based on risk management. The protocol will therefore be dependent on analyser complexity and availability of inbuilt system checks, the risk associated with release of an incorrect patient result as well as frequency of use. The emphasis should be on designing an effective internal quality control protocol as opposed to the inherent tendency of introducing high-frequency quality control. Typically a simple pass or fail criterion is used for internal quality control in point-of-care testing based on whether internal quality control results fall within assigned ranges. While simply taught, such criteria can require broad internal quality control ranges to decrease the probability of false rejection (also reducing the probability of error detection). Customized internal quality control ranges, two-tier acceptance systems and assay-specific internal quality control can be used to improve error detection rates. PMID:26486440

  17. Aitchbone hanging and ageing period are additive factors influencing pork eating quality.

    PubMed

    Channon, H A; Taverner, M R; D'Souza, D N; Warner, R D

    2014-01-01

    The effects of abattoir, carcase weight (60 or 80 kg HCW), hanging method (Achilles or aitchbone) and ageing period (2 or 7 day post-slaughter) on eating quality attributes of pork were investigated in this 3×2×2×2 factorial study. A total of 144 Large White×Landrace female pigs were slaughtered at one of three abattoirs and sides hung from either the Achilles tendon or the aitchbone. After 24 h chilling, loin (M. longissimus thoracis et lumborum) and topside (M. semimembranosus) muscles were individually vacuum packaged and aged for 2 or 7 days post-slaughter. Consumers (n=852) evaluated eating quality. Neither abattoir nor carcase weight influenced tenderness, flavour or overall liking of pork. Improvements in tenderness, flavour and overall liking were found due to aitchbone hanging (P<0.001) and ageing (P<0.001) for 7 days compared with Achilles-hung carcases and pork aged for 2 days, respectively. This study demonstrated that aitchbone hanging and 7 day ageing can improve eating quality, but these effects were additive as the interaction term was not significant. PMID:24013699

  18. The Effect of LAB as Probiotic Starter Culture and Green Tea Extract Addition on Dry Fermented Pork Loins Quality.

    PubMed

    Neffe-Skocińska, Katarzyna; Jaworska, Danuta; Kołożyn-Krajewska, Danuta; Dolatowski, Zbigniew; Jachacz-Jówko, Luiza

    2015-01-01

    The objective of this study was to evaluate the microbiological, physicochemical, and sensory quality of dry fermented pork loin produced with the addition of Lb. rhamnosus LOCK900 probiotic strain, 0.2% glucose, and 1.5% green tea extract. Three loins were prepared: control sample (P0: no additives), sample supplemented with glucose and probiotic strain (P1), and sample with glucose, green tea extract, and probiotic (P2). The samples were analyzed after 21 days of ripening and 180 days of storage. The results indicated that the highest count of LAB was observed both in the samples: with probiotic and with probiotic and green tea extract (7.00 log cfu/g after ripening; 6.00 log cfu/g after storage). The oxidation-reduction potential values were lower in the probiotic loin samples. Probiotic and green tea extract have not caused color changes of study loins during storage. The study demonstrated that an addition of probiotic and green tea extract to dry fermented loins is possible and had no impact on sensory quality after product storage. PMID:25961018

  19. The Effect of LAB as Probiotic Starter Culture and Green Tea Extract Addition on Dry Fermented Pork Loins Quality

    PubMed Central

    Jaworska, Danuta; Kołożyn-Krajewska, Danuta; Dolatowski, Zbigniew; Jachacz-Jówko, Luiza

    2015-01-01

    The objective of this study was to evaluate the microbiological, physicochemical, and sensory quality of dry fermented pork loin produced with the addition of Lb. rhamnosus LOCK900 probiotic strain, 0.2% glucose, and 1.5% green tea extract. Three loins were prepared: control sample (P0: no additives), sample supplemented with glucose and probiotic strain (P1), and sample with glucose, green tea extract, and probiotic (P2). The samples were analyzed after 21 days of ripening and 180 days of storage. The results indicated that the highest count of LAB was observed both in the samples: with probiotic and with probiotic and green tea extract (7.00 log cfu/g after ripening; 6.00 log cfu/g after storage). The oxidation-reduction potential values were lower in the probiotic loin samples. Probiotic and green tea extract have not caused color changes of study loins during storage. The study demonstrated that an addition of probiotic and green tea extract to dry fermented loins is possible and had no impact on sensory quality after product storage. PMID:25961018

  20. Austrian Daily Climate Data Rescue and Quality Control

    NASA Astrophysics Data System (ADS)

    Jurkovic, A.; Lipa, W.; Adler, S.; Albenberger, J.; Lechner, W.; Swietli, R.; Vossberg, I.; Zehetner, S.

    2010-09-01

    Checked climate datasets are a "conditio sine qua non" for all projects that are relevant for environment and climate. In the framework of climate change studies and analysis it is essential to work with quality controlled and trustful data. Furthermore these datasets are used as input for various simulation models. In regard to investigations of extreme events, like strong precipitation periods, drought periods and similar ones we need climate data in high temporal resolution (at least in daily resolution). Because of the historical background - during Second World War the majority of our climate sheets were sent to Berlin, where the historical sheets were destroyed by a bomb attack and so important information got lost - only several climate sheets, mostly duplicates, before 1939 are available and stored in our climate data archive. In 1970 the Central Institute for Meteorology and Geodynamics in Vienna started a first attempt to digitize climate data by means of punch cards. With the introduction of a routinely climate data quality control in 1984 we can speak of high-class-checked daily data (finally checked data, quality flag 6). Our group is working on the processing of digitization and quality control of the historical data for the period 1872 to 1983 for 18 years. Since 2007 it was possible to intensify the work (processes) in the framework of an internal project, namely Austrian Climate Data Rescue and Quality Control. The aim of this initiative was - and still is - to supply daily data in an outstanding good and uniform quality. So this project is a kind of pre-project for all scientific projects which are working with daily data. In addition to routine quality checks (that are running since 1984) using the commercial Bull Software we are testing our data with additional open source software, namely ProClim.db. By the use of this spatial and statistical test procedure, the elements air temperature and precipitation - for several sites in Carinthia - could

  1. Quality assurance standards for purchasing and inventory control.

    PubMed

    Soares, D P

    1985-03-01

    A process is described for quality assurance in pharmaceutical purchasing and inventory control. A quality assurance program should ensure that quality drugs are purchased at the lowest price, drug products are available when needed, the system is managed efficiently, internal controls are provided, drug products are stored under appropriate conditions, and laws, regulations, accreditation standards, and procedures are followed. To meet these objectives, product quality, vendor performance, the department's system of internal controls, purchasing data, and storage conditions should be monitored. A checklist for evaluating purchasing and inventory practices and a sample audit form listing quality assurance criteria, standards, procedures, and recommended actions are provided. A quality assurance program for pharmaceutical purchasing and inventory control should define institution-specific criteria and standards and use these standards for continual evaluation of all aspects of the purchasing and inventory control system. Documentation of quality assurance activities should be provided for use by the purchasing department, hospital administration, and regulatory bodies. PMID:3985026

  2. Mitochondrial Quality Control and Muscle Mass Maintenance

    PubMed Central

    Romanello, Vanina; Sandri, Marco

    2016-01-01

    Loss of muscle mass and force occurs in many diseases such as disuse/inactivity, diabetes, cancer, renal, and cardiac failure and in aging-sarcopenia. In these catabolic conditions the mitochondrial content, morphology and function are greatly affected. The changes of mitochondrial network influence the production of reactive oxygen species (ROS) that play an important role in muscle function. Moreover, dysfunctional mitochondria trigger catabolic signaling pathways which feed-forward to the nucleus to promote the activation of muscle atrophy. Exercise, on the other hand, improves mitochondrial function by activating mitochondrial biogenesis and mitophagy, possibly playing an important part in the beneficial effects of physical activity in several diseases. Optimized mitochondrial function is strictly maintained by the coordinated activation of different mitochondrial quality control pathways. In this review we outline the current knowledge linking mitochondria-dependent signaling pathways to muscle homeostasis in aging and disease and the resulting implications for the development of novel therapeutic approaches to prevent muscle loss. PMID:26793123

  3. Quality control and reliability of reported doses.

    PubMed

    Stadtmann, H; Figel, Markus; Kamenopoulou, V; Kluszczynski, D; Roed, H; Van Dijk, J

    2004-01-01

    Results of performance tests verifying the dosimetric properties of dosimetric systems are published in various reports (e.g. IAEA and EURADOS). However, there is hardly any information in the open literature relating to the uncertainty in a dose measurement or in the annual dose, which is increased by failure of the evaluation or data management system, damage of the dosemeter itself or by the loss of dosemeter. In this article, an attempt is made to estimate the importance of the above-mentioned conditions. This is achieved by sending questionnaires to about 200 approved dosimetric services in Europe. In total 88 questionnaires were returned and analysed. In the questionnaires, the frequency of occurrence of the various error conditions were investigated. Participants were also asked to evaluate the impact of the error condition from a dosimetric point of view and what countermeasures are taken. The article summarises all responses and compares different sources of errors according to their impact on the uncertainty of the resulting dose and gives a comprehensive overview on quality control actions and reliability on reported doses from European dosimetric services. PMID:15574990

  4. Toward standardising gamma camera quality control procedures

    NASA Astrophysics Data System (ADS)

    Alkhorayef, M. A.; Alnaaimi, M. A.; Alduaij, M. A.; Mohamed, M. O.; Ibahim, S. Y.; Alkandari, F. A.; Bradley, D. A.

    2015-11-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services.

  5. Controls on the quality of harvested rainwater in residential systems

    NASA Astrophysics Data System (ADS)

    Sojka, S. L.; Phung, D.; Hollingsworth, C.

    2014-12-01

    Rainwater harvesting systems, in which runoff from roofs is collected and used for irrigation, toilets and other purposes, present a viable solution to limited freshwater supplies and excess stormwater runoff. However, a lack of data on the quality of harvested rainwater hinders adoption of rainwater harvesting systems and makes development of rainwater harvesting regulations difficult. We conducted monthly surveys of 6 existing residential rainwater harvesting systems ranging in age from 1 to 11 years measuring pH, temperature, dissolved oxygen, total suspended solids, dissolved organic carbon, and coliform bacteria. We also examined a subset of the samples for iron, lead, mercury and arsenic. Many of the systems routinely met the water quality requirements for non-potable use without additional treatment, which is often required by regulations. In addition, while previous studies have shown that roof runoff contains heavy metals, the water in all systems showed very low or undetectable levels of metal contamination. Coliform bacteria concentration ranged from 20 to greater than 1400 CFU's per 100 mL and correlated with total suspended solids, which ranged from 2 - 7 mg l-1. The relationship between suspended solids and bacteria population was confirmed in a controlled experiment on the impact of filtering the rainwater before storage. Filtration decreased total suspended solids and total coliforms and increased dissolved oxygen concentration. This project provides insight into the effects of system design and a baseline assessment of the quality of harvested rainwater in existing systems.

  6. Integration of cellular bioenergetics with mitochondrial quality control and autophagy

    PubMed Central

    Hill, Bradford G.; Benavides, Gloria A.; Lancaster, Jack R.; Ballinger, Scott; Dell’Italia, Lou; Zhang, Jianhua; Darley-Usmar, Victor M.

    2013-01-01

    Bioenergetic dysfunction is emerging as a cornerstone for establishing a framework for understanding the pathophysiology of cardiovascular disease, diabetes, cancer and neurodegeneration. Recent advances in cellular bioenergetics have shown that many cells maintain a substantial bioenergetic reserve capacity, which is a prospective index of “healthy” mitochondrial populations. The bioenergetics of the cell are likely regulated by energy requirements and substrate availability. Additionally, the overall quality of the mitochondrial population and the relative abundance of mitochondria in cells and tissues also impinge on overall bioenergetic capacity and resistance to stress. Because mitochondria are susceptible to damage mediated by reactive oxygen/nitrogen and lipid species, maintaining a “healthy” population of mitochondria through quality control mechanisms appears to be essential for cell survival under conditions of pathological stress. Accumulating evidence suggest that mitophagy is particularly important for preventing amplification of initial oxidative insults, which otherwise would further impair the respiratory chain or promote mutations in mitochondrial DNA (mtDNA). The processes underlying the regulation of mitophagy depend on several factors including the integrity of mtDNA, electron transport chain activity, and the interaction and regulation of the autophagic machinery. The integration and interpretation of cellular bioenergetics in the context of mitochondrial quality control and genetics is the theme of this review. PMID:23092819

  7. Quality control on crimping of large diameter welding pipe

    NASA Astrophysics Data System (ADS)

    Fan, Lifeng; Gao, Ying; Li, Qiang; Xu, Hongshen

    2012-11-01

    Crimping is used in production of large diameter submerged-arc welding pipes. Many researches are focused on crimping in certain manufacturing mode of welding pipe. The application scopes of research achievements become limited due to lack of uniformity in theoretical analysis. In order to propose a crimping prediction method in order to control forming quality, the theory model of crimping based on elastic-plastic mechanics is established. The main technical parameters are determined by theoretical analysis, including length of crimping, base radius of punch, terminal angle of punch, base radius of die, terminal angle of die and horizontal distance between punch and die. In addition, a method used to evaluate the forming quality is presented, which investigates the bending angle after springback, forming force, straight edge length and equivalent radius of curvature. In order to investigate the effects of technical parameters on forming quality, a two-dimensional finite element model is established by finite element software ABAQUS. The finite element model is verified in that its shapes error is less than 5% by comparable experiments, which shows that their geometric precision meets demand. The crimping characteristics is obtained, such as the distribution of stress and strain and the changes of forming force, and the relation curves of technical parameters on forming quality are given by simulation analysis. The sensitivity analysis indicates that the effects of length of crimping, technical parameters of punch on forming quality are significant. In particular, the data from simulation analysis are regressed by response surface method (RSM) to establish prediction model. The feasible technical parameters are obtained from the prediction model. This method presented provides a new thought used to design technical parameters of crimping forming and makes a basis for improving crimping forming quality.

  8. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. he document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic drai...

  9. TECHNICAL GUIDANCE DOCUMENT: QUALITY ASSURANCE AND QUALITY CONTROL FOR WASTE CONTAINMENT FACILITIES

    EPA Science Inventory

    This Technical Guidance Document provides comprehensive guidance on procedures for quality assurance and quality control for waste containment facilities. The document includes a discussion of principles and concepts, compacted soil liners, soil drainage systems, geosynthetic dr...

  10. Current good manufacturing practices, quality control procedures, quality factors, notification requirements, and records and reports, for infant formula. Final rule.

    PubMed

    2014-06-10

    The Food and Drug Administration (FDA or we) is issuing a final rule that adopts, with some modifications, the interim final rule (IFR) entitled "Current Good Manufacturing Practices, Quality Control Procedures, Quality Factors, Notification Requirements, and Records and Reports, for Infant Formula'' (February 10, 2014). This final rule affirms the IFR's changes to FDA's regulations and provides additional modifications and clarifications. The final rule also responds to certain comments submitted in response to the request for comments in the IFR. PMID:24922980

  11. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    PubMed

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-01

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant1 software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC . PMID:26653327

  12. International Quality Control Is No Easy Task

    ERIC Educational Resources Information Center

    Contreras, Alan

    2008-01-01

    In early March, the European Quality Assurance Register for Higher Education was established under what is called the Bologna Process. The 46 countries involved in the process seek to improve the quality and assessment of higher education throughout Europe, thus facilitating students' mobility among institutions and countries and enhancing…

  13. Technology to control variation in meat quality

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Consumers have certain expectations regarding the quality of the meat they purchase. Lean color is the primary quality attribute used by consumers to make purchase decisions. Similarly, repeat purchase decisions are generally a result of eating satisfaction, which is determined by the perceived va...

  14. Addition of cholesterol-loaded cyclodextrins to the thawing extender: effects on boar sperm quality.

    PubMed

    Tomás, C; Gómez-Fernández, J; Gómez-Izquierdo, E; Mocé, E; de Mercado, E

    2014-06-01

    The aim of the present study was to evaluate the effect that the addition of cholesterol-loaded cyclodextrins (CLC) to the thawing extender has on the quality of frozen-thawed boar sperm. Pooled semen (n = 5) from three boars was used for the experiments. The semen was cryopreserved with an egg-yolk-based extender, it was diluted after thawing in Beltsville thawing solution (BTS) supplemented with different concentrations of CLC (0, 12.5, 25, 50 or 100 mg/500 × 10(6) sperm), and these samples were incubated at 37°C for 150 min. The following parameters of sperm quality were evaluated 30 and 150 min after incubation: sperm with intact plasma membrane (SIPM; %), sperm with normal acrosomal ridge (NAR; %), total motile sperm (TMS; %), progressively motile sperm (PMS; %) and kinetic parameters. Both SIPM and NAR increased (p < 0.05) when the thawing extender was supplemented with 12.5, 25 and 50 mg CLC/500 × 10(6) sperm. Nevertheless, motility decreased (p < 0.05) when the concentration of CLC exceeded 12.5 mg CLC/500 × 10(6) sperm. In conclusion, our results suggest that the supplementation of thawing extenders with CLC improves sperm viability and reduces acrosome damage after freezing/thawing. PMID:24593058

  15. [Improvement of routine works and quality control in mycobacterial laboratory].

    PubMed

    Suzuki, Katsuhiro; Higuchi, Takeshi

    2007-03-01

    Many new methods have been introduced into routine laboratory works in microbiology since 1990. Molecular biology, in particular, opened a new era and promoted a technician's skill much. PCR and hybridization technique have been ordinary one in many laboratories. Since old techniques such as smear and culture are still needed, amount of routine works is increasing gradually. Thus, improving efficiency and keeping quality of routine works are becoming more and more important issues. This symposium focused on such points, and four skilled technicians around Japan presented their own tips. 1. Coexistence of M. tuberculosis and M. avium complex (MAC) in the MGIT culture system: Yasushi WATANABE (Clinical Laboratory Division, NHO Nishi-Niigata Chuo National Hospital). Sputum samples of some tuberculosis patients yielded only MAC in the MGIT culture system. Such co-infected cases presented problems to mislead proper treatment and infection control. The detection rate of MAC was significantly high, and the growth speed of MAC was significantly rapid in the MGIT culture system, compared to those of M. tuberculosis. Additionally, M. tuberculosis was not detected with even more quantity than MAC in the small amount of mixed samples. Higher sensitivity and growth speed of MAC are the important characteristics of the MGIT system. 2. Internal quality control with ordinary examination results: Akio AONO (Department of Clinical Examination, Double-Barred Cross Hospital, Japan Anti-Tuberculosis Association). Our laboratory utilizes ordinary examination results as the internal quality control for specimen pretreatment, culture, and drug susceptibility testing. The contamination rate of MGIT culture system is useful for the evaluation of the decontamination process. It was 6.3% on average in our laboratory in 2005. The number of drug resistant strains is also useful to assess the performance of drug susceptibility testing. The incidence of each anti-tuberculosis drug resistance

  16. Real-time control of combined surface water quantity and quality: polder flushing.

    PubMed

    Xu, M; van Overloop, P J; van de Giesen, N C; Stelling, G S

    2010-01-01

    In open water systems, keeping both water depths and water quality at specified values is critical for maintaining a 'healthy' water system. Many systems still require manual operation, at least for water quality management. When applying real-time control, both quantity and quality standards need to be met. In this paper, an artificial polder flushing case is studied. Model Predictive Control (MPC) is developed to control the system. In addition to MPC, a 'forward estimation' procedure is used to acquire water quality predictions for the simplified model used in MPC optimization. In order to illustrate the advantages of MPC, classical control [Proportional-Integral control (PI)] has been developed for comparison in the test case. The results show that both algorithms are able to control the polder flushing process, but MPC is more efficient in functionality and control flexibility. PMID:20182064

  17. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... management of quality, including: (1) Requirements for the production of quality data and the use of quality... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from DODSSP, Standardization..., manufacturing, and fabrication, inspections are adequate to ensure control of finished article...

  18. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... management of quality, including: (1) Requirements for the production of quality data and the use of quality... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from DODSSP, Standardization..., manufacturing, and fabrication, inspections are adequate to ensure control of finished article...

  19. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... management of quality, including: (1) Requirements for the production of quality data and the use of quality... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from DODSSP, Standardization..., manufacturing, and fabrication, inspections are adequate to ensure control of finished article...

  20. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... management of quality, including: (1) Requirements for the production of quality data and the use of quality... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from DODSSP, Standardization..., manufacturing, and fabrication, inspections are adequate to ensure control of finished article...

  1. Integrated Quality Control Measurement Project. Findings and Corrective Actions.

    ERIC Educational Resources Information Center

    Price Waterhouse and Co., New York, NY.

    The Integrated Quality Control Measurement Project (IQCMP) of the U.S. Department of Education measured the quality of awards distributed during the 1988-89 award year under the three major Title IV programs: the Pell Grant program, the Campus-Based programs, and the Stafford Loan program, in order to evaluate and improve the quality of the…

  2. Food and Nutrition Services Quality Control Management Program.

    ERIC Educational Resources Information Center

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  3. Space Shuttle flying qualities and flight control system assessment study

    NASA Technical Reports Server (NTRS)

    Myers, T. T.; Johnston, D. E.; Mcruer, D.

    1982-01-01

    The suitability of existing and proposed flying quality and flight control system criteria for application to the space shuttle orbiter during atmospheric flight phases was assessed. An orbiter experiment for flying qualities and flight control system design criteria is discussed. Orbiter longitudinal and lateral-directional flying characteristics, flight control system lag and time delay considerations, and flight control manipulator characteristics are included. Data obtained from conventional aircraft may be inappropriate for application to the shuttle orbiter.

  4. Adaptive Quality of Transmission Control in Elastic Optical Network

    NASA Astrophysics Data System (ADS)

    Cai, Xinran

    Optical fiber communication is becoming increasingly important due to the burgeoning demand in the internet capacity. However, traditional wavelength division multiplexing (WDM) technique fails to address such demand because of its inefficient spectral utilization. As a result, elastic optical networking (EON) has been under extensive investigation recently. Such network allows sub-wavelength and super-wavelength channel accommodation, and mitigates the stranded bandwidth problem in the WDM network. In addition, elastic optical network is also able to dynamically allocate the spectral resources of the network based on channel conditions and impairments, and adaptively control the quality of transmission of a channel. This application requires two aspects to be investigated: an efficient optical performance monitoring scheme and networking control and management algorithms to reconfigure the network in a dynamic fashion. This thesis focuses on the two aspects discussed above about adaptive QoT control. We demonstrated a supervisory channel method for optical signal to noise ratio (OSNR) and chromatic dispersion (CD) monitoring. In addition, our proof-of-principle testbed experiments show successful impairment aware reconfiguration of the network with modulation format switching (MFS) only and MFS combined with lightpath rerouting (LR) for hundred-GHz QPSK superchannels undergoing time-varying OSNR impairment.

  5. Effect of calcium chloride addition on ice cream structure and quality.

    PubMed

    Costa, F F; Resende, J V; Abreu, L R; Goff, H D

    2008-06-01

    The influence of calcium fortification by the addition of calcium chloride on quality parameters of ice cream based on physical properties was investigated, as was the effect of kappa-carrageenan at modifying the effects of this calcium fortification. Four ice cream mixes of conventional composition, with added kappa-carrageenan (0 or 0.025%) and added calcium chloride (0 or 4.4 g L(-1) = 40 mM of added Ca(2+)), were prepared. Modulated temperature-differential scanning calorimetry was used to investigate the effect of calcium chloride on the nucleation temperature, enthalpy of melting, and freezing point depression. The protein composition of 15.4% (wt/wt) reconstituted skim milk powder solutions with or without 4.4 g L(-1) added CaCl(2) and in the supernatant after ultracentrifugation was determined. Fat particle size distributions in ice cream were characterized by light scattering. Ice crystal sizes before and after temperature cycling were determined by cold-stage light microscopy. The results demonstrated that the addition of calcium chloride led to a substantial increase in ice crystal sizes and in fat partial coalescence, which were exacerbated by the addition of kappa-carrageenan. These results can be explained by the interaction between Ca(2+) ions and casein micelles, rather than any effects on freezing point depression. The calcium ions led to a more compact micelle, less serum beta-casein, and high fat destabilization, all of which would be expected to reduce macromolecular structure and volume occupancy in the unfrozen phase, which led to increased rates of ice recrystallization. PMID:18487638

  6. US quality control in Italy: present and future

    NASA Astrophysics Data System (ADS)

    Balbis, S.; Musacchio, C.; Guiot, C.; Spagnolo, R.

    2011-02-01

    US diagnostic equipments are widely diffused in Italy but, in spite of recommendations (e.g. ISPESL-Ministry of Health (1999) and SIRM (Società Italiana di Radiologia Medica, 2004), US quality controls are restricted to only a few public sanitary structure and a national (or even regional) quality assurance program for testing the performances of the US equipments is still missing. A joint Research Centre among the three Piedmontese Universities and INRIM, partially funded by Regione Piemonte, has been established in 2009 as Reference Centre for Medical Ultrasounds (CRUM). In addition to research, development and training tasks, the Centre aims at the local diffusion of the quality assurance in clinical US equipments. According to data from the Ministry of Health (2006), around 7 % of the Italian US diagnostic equipments (946 over 13526) are located in Piedmont: mostly (75.6%) in public hospitals, 9.3 % in conventionated hospitals, 4.3% in public and 10.8% in private territorial structures. The goal is the provision of a regional database, which progressively includes data related to acceptance test, status and QC tests and maintenance, in order to drive equipment turnover and carefully monitoring the overall equipment efficiency. Moreover, facilities are available at CRUM for monitoring both beam geometry and acoustic power and performing quantitative assessment of the delivered energy intensity.

  7. 46 CFR 164.019-13 - Production quality control requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.019-13 Section 164.019-13 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Personal Flotation Device Components § 164.019-13 Production quality control...

  8. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to the FAA that ensures the airworthiness of the articles on which the repair station or any of...

  9. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to the FAA that ensures the airworthiness of the articles on which the repair station or any of...

  10. 14 CFR 145.211 - Quality control system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to the FAA that ensures the airworthiness of the articles on which the repair station or any of...

  11. Quality Control Study of the GSL Reinsurance System. Final Report.

    ERIC Educational Resources Information Center

    Advanced Technology, Inc., Reston, VA.

    A quality control plan for the U.S. Department of Education's Guaranteed Student Loan (GSL) reinsurance process was developed. To identify existing errors, systems documentation and past analyses of the reinsurance system were analyzed, and interviews were conducted. Corrective actions were proposed, and a quality control checklist was developed…

  12. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section 58.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a)...

  13. Building Science Corporation's Building America Quality Control Checklist

    SciTech Connect

    2008-10-05

    The Building America Quality Control Checklist has been developed as both a guide to assist in the transition to high performance home building, and as a simplified tool to be used as part of any builder's on-site quality control procedures.

  14. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Laboratory and quality control tests. 58.442 Section 58.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a)...

  15. 7 CFR 58.442 - Laboratory and quality control tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Laboratory and quality control tests. 58.442 Section 58.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a)...

  16. Artificial Intelligence Approach to Support Statistical Quality Control Teaching

    ERIC Educational Resources Information Center

    Reis, Marcelo Menezes; Paladini, Edson Pacheco; Khator, Suresh; Sommer, Willy Arno

    2006-01-01

    Statistical quality control--SQC (consisting of Statistical Process Control, Process Capability Studies, Acceptance Sampling and Design of Experiments) is a very important tool to obtain, maintain and improve the Quality level of goods and services produced by an organization. Despite its importance, and the fact that it is taught in technical and…

  17. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good...

  18. For and against a European quality control of training.

    PubMed

    Dimitrakakis, C; Michalas, S

    2001-01-01

    In a world of medicine that evolves more and more rapidly, sufficient quality of education in the arts and crafts of our discipline and control of this quality are essential for the progress and vitality of Ob/Gyn. There are variations in training within European countries but with the aim of harmonization in training programmes and the flexibility of quality control mechanisms we will meet our objective that is the high standards in the care of woman throughout Europe. PMID:11205701

  19. Continuous Software Integration and Quality Control during Software Development

    NASA Astrophysics Data System (ADS)

    Ettl, M.; Neidhardt, A.; Brisken, W.; Dassing, R.

    2012-12-01

    Modern software has to be stable, portable, fast, and reliable. This requires a sophisticated infrastructure supporting and providing the developers with additional information about the state and the quality of the project. That is why we have created a centralized software repository, where the whole code-base is managed and version controlled on a centralized server. Based on this, a hierarchical build system has been developed where each project and their sub-projects can be compiled by simply calling the top level Makefile. On the top of this, a nightly build system has been created where the top level Makefiles of each project are called every night. The results of the build including the compiler warnings are reported to the developers using generated HTML pages. In addition, all the source code is automatically checked using a static code analysis tool, called "cppcheck". This tool produces warnings, similar to those of a compiler, but more pedantic. The reports of this analysis are translated to HTML and reported to the developers similar to the nightly builds. Armed with this information,the developers can discover issues in their projects at an early development stage. In combination it reduces the number of possible issues in our software to ensure quality of our projects at different development stages. These checks are also offered to the community. They are currently used within the DiFX software correlator project.

  20. 40 CFR Appendix B to Part 75 - Quality Assurance and Quality Control Procedures

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Quality Assurance and Quality Control Procedures B Appendix B to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. B Appendix B to Part 75—Quality...

  1. The interpretation of flying qualities requirements for flight control system design

    NASA Technical Reports Server (NTRS)

    Rynaski, E. G.

    1985-01-01

    An experimental flight test program was designed for the Total In Flight Simulator (TIFS) directed toward the interface between flying qualities requirements and flight control system design criteria. The eventual goal is to provide an interpretation or translation of flying qualities requirements for use by the flight control system designer. Specifically, an angle of attack and pitch rate command system matrix involving both short term and long term dynamics are specified for evaluation. Flying qualities criteria and flight control system configuration or architecture can be independent was demonstrated. Finally, additional configurations are proposed to evaluate the efficacy of dynamic decoupling.

  2. Continuous integration and quality control for scientific software

    NASA Astrophysics Data System (ADS)

    Neidhardt, A.; Ettl, M.; Brisken, W.; Dassing, R.

    2013-08-01

    Modern software has to be stable, portable, fast and reliable. This is going to be also more and more important for scientific software. But this requires a sophisticated way to inspect, check and evaluate the quality of source code with a suitable, automated infrastructure. A centralized server with a software repository and a version control system is one essential part, to manage the code basis and to control the different development versions. While each project can be compiled separately, the whole code basis can also be compiled with one central “Makefile”. This is used to create automated, nightly builds. Additionally all sources are inspected automatically with static code analysis and inspection tools, which check well-none error situations, memory and resource leaks, performance issues, or style issues. In combination with an automatic documentation generator it is possible to create the developer documentation directly from the code and the inline comments. All reports and generated information are presented as HTML page on a Web server. Because this environment increased the stability and quality of the software of the Geodetic Observatory Wettzell tremendously, it is now also available for scientific communities. One regular customer is already the developer group of the DiFX software correlator project.

  3. Quality control and analytical methods for baculovirus-based products.

    PubMed

    Roldão, António; Vicente, Tiago; Peixoto, Cristina; Carrondo, Manuel J T; Alves, Paula M

    2011-07-01

    Recombinant baculoviruses (rBac) are used for many different applications, ranging from bio-insecticides to the production of heterologous proteins, high-throughput screening of gene functions, drug delivery, in vitro assembly studies, design of antiviral drugs, bio-weapons, building blocks for electronics, biosensors and chemistry, and recently as a delivery system in gene therapy. Independent of the application, the quality, quantity and purity of rBac-based products are pre-requisites demanded by regulatory authorities for product licensing. To guarantee maximization utility, it is necessary to delineate optimized production schemes either using trial-and-error experimental setups ("brute force" approach) or rational design of experiments by aid of in silico mathematical models (Systems Biology approach). For that, one must define all of the main steps in the overall process, identify the main bioengineering issues affecting each individual step and implement, if required, accurate analytical methods for product characterization. In this review, current challenges for quality control (QC) technologies for up- and down-stream processing of rBac-based products are addressed. In addition, a collection of QC methods for monitoring/control of the production of rBac derived products are presented as well as innovative technologies for faster process optimization and more detailed product characterization. PMID:21784235

  4. Quality of Life and Neutropenia in Patients with Early Stage Breast Cancer: A Randomized Pilot Study Comparing Additional Treatment with Mistletoe Extract to Chemotherapy Alone

    PubMed Central

    Tröger, Wilfried; Jezdić, Svetlana; Ždrale, Zdravko; Tišma, Nevena; Hamre, Harald J.; Matijašević, Miodrag

    2009-01-01

    Background: Chemotherapy for breast cancer often deteriorates quality of life, augments fatigue, and induces neutropenia. Mistletoe preparations are frequently used by cancer patients in Central Europe. Physicians have reported better quality of life in breast cancer patients additionally treated with mistletoe preparations during chemotherapy. Mistletoe preparations also have immunostimulant properties and might therefore have protective effects against chemotherapy-induced neutropenia. Patients and Methods: We conducted a prospective randomized open label pilot study with 95 patients randomized into three groups. Two groups received Iscador® M special (IMS) or a different mistletoe preparation, respectively, additionally to chemotherapy with six cycles of cyclophosphamide, adriamycin, and 5-fluoro-uracil (CAF). A control group received CAF with no additional therapy. Here we report the comparison IMS (n = 30) vs. control (n = 31). Quality of life including fatigue was assessed with the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC-QLQ-C30). Neutropenia was defined as neutrophil counts <1,000/μl and assessed at baseline and one day before each CAF cycle. Results: In the descriptive analysis all 15 scores of the EORTC-QLQ-C30 showed better quality of life in the IMS group compared to the control group. In 12 scores the differences were significant (p < 0.02) and nine scores showed a clinically relevant and significant difference of at least 5 points. Neutropenia occurred in 3/30 IMS patients and in 8/31 control patients (p = 0.182). Conclusions: This pilot study showed an improvement of quality of life by treating breast cancer patients with IMS additionally to CAF. CAF-induced neutropenia showed a trend to lower frequency in the IMS group. PMID:21556248

  5. Concepts for continuous quality monitoring and station remote control

    NASA Astrophysics Data System (ADS)

    Ettl, M.; Neidhardt, A.; Rottmann, H.; Mühlbauer, M.; Plötz, C.; Himwich, E.; Beaudoin, C.; Szomoru, A.

    2011-07-01

    In the newly funded "Novel EXploration Pushing Robuste-VLBI Services", - project (NEXPReS) the Technische Universitaet Muenchen realize concepts for continuous quality monitoring and station remote control in cooperation with the Max-Planck-Institute for Radioastronomy, Bonn. NEXPReS is a three-year project aimed at further developing e-VLBI services of the European VLBI Network (EVN), with the goal of incorporating e-VLBI into every astronomical observation conducted by the EVN. This project focus on developments of an operational e-control system with authentication and authorization. It includes an appropriate role management with different remote access states for future observation strategies. To allow a flexible control of different systems in parallel sophisticated graphical user interfaces are designed and realized. It requires also a session oriented data management. Because of the higher degree of automation additional system parameters and information is collected with a new system monitoring. The whole system for monitoring and control is fully compatible to the NASA field system as extension. The concept will be proofed with regular tests between Wettzell and Effelsberg.

  6. Ride quality sensitivity to SAS control law and to handling quality variations

    NASA Technical Reports Server (NTRS)

    Roberts, P. A.; Schmidt, D. K.; Swaim, R. L.

    1976-01-01

    The RQ trends which large flexible aircraft exhibit under various parameterizations of control laws and handling qualities are discussed. A summary of the assumptions and solution technique, a control law parameterization review, a discussion of ride sensitivity to handling qualities, and the RQ effects generated by implementing relaxed static stability configurations are included.

  7. Chemical and Sensory Quality Preservation in Coated Almonds with the Addition of Antioxidants.

    PubMed

    Larrauri, Mariana; Demaría, María Gimena; Ryan, Liliana C; Asensio, Claudia M; Grosso, Nelson R; Nepote, Valeria

    2016-01-01

    Almonds provide many benefits such as preventing heart disease due to their high content of oleic fatty acid-rich oil and other important nutrients. However, they are susceptible to oxidation reactions causing rancidity during storage. The objective of this work was to evaluate the chemical and sensory quality preservation of almonds coated with carboxymethyl cellulose and with the addition of natural and synthetic antioxidants during storage. Four samples were prepared: almonds without coating (C), almonds coated with carboxymethyl cellulose (CMC), almonds coated with CMC supplemented with peanut skins extract (E), and almonds coated with CMC and supplemented with butylhydroxytoluene (BHT). Proximate composition and fatty acid profile were determined on raw almonds. Almond samples (C, CMC, E and BHT) were stored at 40 °C for 126 d. Lipid oxidation indicators: peroxide value (PV), conjugated dienes (CD), volatile compounds (hexanal and nonanal), and sensory attributes were determined for the stored samples. Samples showed small but significant increases in PV, CD, hexanal and nonanal contents, and intensity ratings of negative sensory attributes (oxidized and cardboard). C had the highest tendency to deterioration during storage. At the end of storage (126 d), C had the highest PV (3.90 meqO2 /kg), and BHT had the lowest PV (2.00 meqO2 /kg). CMC and E samples had similar intermediate PV values (2.69 and 2.57 meqO2 /kg, respectively). CMC coating and the addition of natural (peanut skin extract) and synthetic (BHT) antioxidants provide protection to the roasted almond product. PMID:26595771

  8. CNV-based genome wide association study reveals additional variants contributing to meat quality in swine

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Pork quality is important both to the meat processing industry and consumers’ purchasing attitudes. Copy number variation (CNV) is a burgeoning kind of variant that may influence meat quality. Herein, a genome-wide association study (GWAS) was performed between CNVs and meat quality traits in swine....

  9. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    SciTech Connect

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  10. Quality control of coins mint using PIXE and RBS analysis

    NASA Astrophysics Data System (ADS)

    Roumie, M.; Nsouli, B.; Chalhoub, G.; Hamdan, M.

    2010-06-01

    PIXE and RBS analysis is used to investigate the elemental content of modern Lebanese coins, in order to control their minting quality. The coins of interest were 100, 250 and 500 Lebanese Lira (LL), which are mainly bulky metals with or without coated layer. Using 3 MeV protons, proton induced X-ray emission PIXE identified and quantified elements while Rutherford backscattering spectrometry RBS checked the thickness of the coated layer. Indeed, the combination of PIXE and RBS provides a powerful tool to investigate the elemental composition of coins, either modern or ancient. In addition, the experimental protocol was checked by analyzing some other coins of known composition, such as 1-euro and 2-euro.

  11. The VHL short variant involves in protein quality control.

    PubMed

    Liu, Yanbin; Yang, Haixia; Zuo, Feifei; Chen, Liang

    2016-09-01

    The von Hippel-Lindau (VHL) is the most important and frequently mutated gene in human clear cell renal cell carcinoma (ccRCC). In contrast to its long counterpart, the internal translational variant of VHL protein (VHLs) is evolutionarily conserved. Herein we present evidence that VHLs associates with ribosome complex via interaction with the large subunit 6 (RPL6). Manipulation of VHLs expression significantly alters protein synthesis, cell size and mitochondrial mass. VHLs deficiency leads to remarkable sensitivity to drug treatments eliciting nascent protein mis-folding and translational errors. The ubiquitination of nascent peptides are dramatically increased upon the ectopic over-expression of VHLs, which simultaneously co-localizes with proteasome and thus may facilitate the ubiquitin-proteasome mediated degradation. In summary, VHLs contributes to protein quality control in addition to its canonical function in maintaining homeostasis of hypoxia-induced factors alpha subunit (HIFα) in response to environmental oxygen supply. PMID:27196060

  12. Supplemental Control for Aircraft Riding Qualities

    NASA Technical Reports Server (NTRS)

    Williams, Rolanda S.; Ashokkumar, C. R.; Homaifar, Abdollah

    1997-01-01

    The concept of preview control has been applied and proven to be successful in the automotive vehicle. These same concepts are now applied to an aircraft under the assumption that exogenous inputs (wind gust, turbulence, etc. ) can be measured. A supplemental control law for surface deflection is designed to compensate for the loss in performance in the presence of atmospheric disturbances. Fuzzy logic control is employed to handle the nonlinear, time varying characteristics of the disturbance. A methodology to tune the outer loop control parameters is presented.

  13. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SO2 monitoring system shall be considered out-of-control. The length of the out-of-control period..., non-quality-assured data for each disapproved system. (2) Out-of-control period. Whenever a continuous... other audit, the system is out-of-control. The owner or operator shall follow the procedures for...

  14. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SO2 monitoring system shall be considered out-of-control. The length of the out-of-control period..., non-quality-assured data for each disapproved system. (2) Out-of-control period. Whenever a continuous... other audit, the system is out-of-control. The owner or operator shall follow the procedures for...

  15. Addition of intrathecal fentanyl to bupivacaine clonidine mixture effect on quality of subarachnoid block and postoperative analgesia

    PubMed Central

    Nazareth, Marilyn; Ghoshal, Pabitra; Namshikar, Viraj; Gaude, Yogesh

    2013-01-01

    Context: This study was undertaken in 100 patients scheduled for lower limb orthopaedic surgeries. Aim: The objective of this study was to study the effect of addition of intrathecal fentanyl to bupivacaine clonidine mixture on the quality of subarachnoid block and compare it with intrathecal bupivacaine clonidine mixture without fentanyl. Settings and Design: In this prospective and double blind randomized controlled study, one hundred patients, between 20-40 years of age, of either sex, weighing between 40-65 Kg, measuring more than 150 cm in height, of ASA Grade I and II who were undergoing orthopaedic lower limb surgeries were selected in order to study the quality of subarachnoid block and post-operative analgesia produced by a combination of bupivacaine clonidine and fentanyl in comparison with bupivacaine clonidine. Materials and Methods: The patients were randomly divided in two groups of 50 each: Group BC: 2.4 ml of 0.5% hyperbaric bupivacaine (12 mg) + 0.2 ml (30 μg) clonidine + 0.4 ml of 0.9% NaCl. Group BCF: 2.4 ml of 0.5% hyperbaric bupivacaine (12 mg) + 0.2 ml (30 μg) clonidine + 0.4 ml (20 μg) of fentanyl. The total volume of solution in both the groups was 3.0 ml. The quality of subarachnoid block and post-operative analgesia were studied. Statistical Analysis Used: The data thus obtained was statistically analysed using the following tests: Unpaired student's t-test. Average % change in data over baseline values to detect trends. A ‘P’ value of <0.05 was considered to be statistically significant. Results: There was no significant difference in duration of sensory and motor blockade in group BCF compared to BC. The duration of analgesia as assessed by, either VAS score of >5 or demand of additional analgesia was > 524.6 ± 32.21 mins in group BC and > 774.4 ± 59.59 mins in group BCF. This prolongation of duration of analgesia in group BCF compared to group BC has statistical significance. Blood pressure and heart rate changes were not

  16. Additional Therapy with a Mistletoe Product during Adjuvant Chemotherapy of Breast Cancer Patients Improves Quality of Life: An Open Randomized Clinical Pilot Trial.

    PubMed

    Tröger, Wilfried; Zdrale, Zdravko; Tišma, Nevena; Matijašević, Miodrag

    2014-01-01

    Background. Breast cancer patients receiving adjuvant chemotherapy often experience a loss of quality of life. Moreover chemotherapy may induce neutropenia. Patients report a better quality of life when additionally treated with mistletoe products during chemotherapy. Methods. In this prospective randomized open-label pilot study 95 patients were randomized into three groups. All patients were treated with an adjuvant chemotherapy. The primary objective of the study was quality of life, the secondary objective was neutropenia. Here we report the comparison of HxA (n = 34) versus untreated control (n = 31). Results. In the explorative analysis ten of 15 scores of the EORTC QLQ-C30 showed a better quality of life in the HxA group compared to the control group (P < 0.001 to P = 0.038 in Dunnett-T3 test). The difference was clinically relevant (difference of at least 5 points, range 5.4-12.2) in eight of the ten scores. Neutropenia occurred in 7/34 HxA patients and in 8/31 control patients (P = 0.628). Conclusions. This pilot study showed an improvement of quality of life by treating breast cancer patients with HxA additionally to CAF. Although the open design may be a limitation, the findings show the feasibility of a confirmatory study using the methods described here. PMID:24701238

  17. Additional Therapy with a Mistletoe Product during Adjuvant Chemotherapy of Breast Cancer Patients Improves Quality of Life: An Open Randomized Clinical Pilot Trial

    PubMed Central

    Tröger, Wilfried; Ždrale, Zdravko; Tišma, Nevena; Matijašević, Miodrag

    2014-01-01

    Background. Breast cancer patients receiving adjuvant chemotherapy often experience a loss of quality of life. Moreover chemotherapy may induce neutropenia. Patients report a better quality of life when additionally treated with mistletoe products during chemotherapy. Methods. In this prospective randomized open-label pilot study 95 patients were randomized into three groups. All patients were treated with an adjuvant chemotherapy. The primary objective of the study was quality of life, the secondary objective was neutropenia. Here we report the comparison of HxA (n = 34) versus untreated control (n = 31). Results. In the explorative analysis ten of 15 scores of the EORTC QLQ-C30 showed a better quality of life in the HxA group compared to the control group (P < 0.001 to P = 0.038 in Dunnett-T3 test). The difference was clinically relevant (difference of at least 5 points, range 5.4–12.2) in eight of the ten scores. Neutropenia occurred in 7/34 HxA patients and in 8/31 control patients (P = 0.628). Conclusions. This pilot study showed an improvement of quality of life by treating breast cancer patients with HxA additionally to CAF. Although the open design may be a limitation, the findings show the feasibility of a confirmatory study using the methods described here. PMID:24701238

  18. Preliminary evaluation of feeder and lint slide moisture addition on ginning, fiber quality, and textile processing of western cotton

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The objective of this study was to evaluate the effects of moisture addition at the gin stand feeder conditioning hopper and/or the battery condenser slide on gin performance and Western cotton fiber quality and textile processing. The test treatments included no moisture addition, feeder hopper hum...

  19. Statistical process control for total quality

    NASA Astrophysics Data System (ADS)

    Ali, Syed W.

    1992-06-01

    The paper explains the techniques and applications of statistical process control (SPC). Examples of control charts used in the Poseidon program of the NASA ocean topography experiment (TOPEX) and a brief discussion of Taguchi methods are presented. It is noted that SPC involves everyone in process improvement by providing objective, workable data. It permits continuous improvement instead of merely aiming for all parts to be within a tolerance band.

  20. Web quality control for lectures: Supercourse and Amazon.com.

    PubMed

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences. PMID:16342339

  1. Achieving indoor air quality through contaminant control

    SciTech Connect

    Katzel, J.

    1995-07-10

    Federal laws outlining industry`s responsibilities in creating a healthy, hazard-free workspace are well known. OSHA`s laws on interior air pollution establish threshold limit values (TLVs) and permissible exposure limits (PELs) for more than 500 potentially hazardous substances found in manufacturing operations. Until now, OSHA has promulgated regulations only for the manufacturing environment. However, its recently-proposed indoor air quality (IAQ) ruling, if implemented, will apply to all workspaces. It regulates IAQ, including environmental tobacco smoke, and requires employers to write and implement IAQ compliance plans.

  2. Quality Control of Fungal and Viral Biocontrol Agents

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Constraints to the use of the “inundative” or “biopesticide” strategy of biological control include a lack of consistent pest control efficacy, short product shelf-life, and costly production and stabilization processes. Quality control measures that standardize the production, stabilization, formu...

  3. Mesh quality control for multiply-refined tetrahedral grids

    NASA Technical Reports Server (NTRS)

    Biswas, Rupak; Strawn, Roger

    1994-01-01

    A new algorithm for controlling the quality of multiply-refined tetrahedral meshes is presented in this paper. The basic dynamic mesh adaption procedure allows localized grid refinement and coarsening to efficiently capture aerodynamic flow features in computational fluid dynamics problems; however, repeated application of the procedure may significantly deteriorate the quality of the mesh. Results presented show the effectiveness of this mesh quality algorithm and its potential in the area of helicopter aerodynamics and acoustics.

  4. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    ERIC Educational Resources Information Center

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  5. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING...) Each quality control plan shall contain provisions for the management of quality, including: (1... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and...

  6. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING...) Each quality control plan shall contain provisions for the management of quality, including: (1... Specification MIL-F-15160D is available for examination at the U.S. Department of Labor, Mine Safety and...

  7. 115. QUALITY CONTROL BOARD FOR MAINTENANCE AND INSPECTION AT SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    115. QUALITY CONTROL BOARD FOR MAINTENANCE AND INSPECTION AT SOUTH SIDE OF MECHANICAL AND ELECTRICAL ROOM (110), LSB (BLDG. 770), FACING WEST ON EXTERIOR WALL OF QUALITY ASSURANCE ROOM (106A) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. 42 CFR 84.41 - Quality control plans; contents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from DODSSP, Standardization... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality...

  9. A quality control program for waste disposal vault closure

    SciTech Connect

    Benny, H.L.

    1994-07-01

    This paper provides a review of the quality control program employed for closure for a radioactive waste disposal vault at Hanford Washington. The major elements of the program are discussed, as well as the testing results and lessons learned.

  10. Quality control system response to stochastic growth of amyloid fibrils.

    PubMed

    Pigolotti, Simone; Lizana, Ludvig; Otzen, Daniel; Sneppen, Kim

    2013-05-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system periodically breaks down, allowing for formation of large aggregates. We discuss how these periodic breakdowns may constitute a mechanism for the development of neurodegenerative diseases. PMID:23524241

  11. VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN

    EPA Science Inventory

    This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...

  12. 7 CFR 58.733 - Quality control tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be performed in accordance with the appropriate edition of the Official Methods of Analysis of the AOAC as... Cheese Products Bearing USDA Official Identification...

  13. Improving the quality of polymer-coated urea with recycled plastic, proper additives, and large tablets.

    PubMed

    Yang, Yue-Chao; Zhang, Min; Li, Yuncong; Fan, Xiao-Hui; Geng, Yu-Qing

    2012-11-14

    Polymer-coated urea (PCU) has great potential for increasing crop production and enhancing nitrogen (N) fertilizer use efficiency, benefiting the ecosystem. However, current PCUs are used only in a limited market, and the main obstacle to the wider use of PCUs is high cost compared to that of conventional N fertilizers. In this study, the low cost PCU and large tablet polymer-coated urea (LTPCU) were prepared by using recycling polystyrene foam and various sealants as the coating materials. The structural and chemical characteristics of the coating shells of the coated fertilizers were examined. The N release characteristics of coated fertilizers were determined in 25 °C water under laboratory conditions. The relationship between the N release longevity and the amount of coating material and the percentage of different sealants were evaluated. The results indicated that recycling polystyrene foam was the ideal coating material of the controlled release fertilizer. The polyurethane that was synthesized by the reaction of castor oil and isocyanate was better than the wax as the additive to delay the N release rate of coated urea. The coating material used for LTPCU was 70-80% less than those used for commercial PCUs under the same N release longevity. The cost of the recycling polystyrene foam used for coating one ton of pure N of the LTPCU was about one-seventh to one-eighth of the cost of the traditional polymer used for the commercial PCU. The experimental data showed that the LTPCU with good controlled-release capacities, being economical and eco-friendly, could be promising for wide use in agriculture and horticulture. PMID:23094596

  14. Development of Quality Control Procedures for Lepidoptera

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Lepidopteran species are among the most destructive insect pests throughout the world. The sterile insect technique (SIT), within an area-wide integrated pest management (AW-IPM) approach, has proven to be a valuable tactic for controlling and eradicating important moth pests. Improving laboratory...

  15. Proper use of sludge-control additives in residential heating oil systems

    SciTech Connect

    Tatnall, R.E.

    1995-04-01

    Discussed are various aspects of heating oil `sludge`: How it forms, typical problems it causes, how sludge-control additives work, what should be expected of them, and what happens in a contaminated system when such additives are used. Test results from laboratory and field experiments demonstrate that performance of commercially available additives varies greatly. The concept of `end-of-the-line` treatment is described and compared with bulk fuel treatment. A procedure is described whereby a retailer can test additives himself, and thus determine just what those additives will or will not do for his business. Finally, the economics of an effective treatment program are outlined.

  16. Experience with ISO quality control in assisted reproductive technology.

    PubMed

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement. PMID:24112531

  17. Quality control standards in PGD and PGS.

    PubMed

    SenGupta, S B; Dhanjal, S; Harper, J C

    2016-03-01

    Preimplantation genetic diagnosis (PGD) aims to test the embryo for specific conditions before implantation in couples at risk of transmitting genetic abnormality to their offspring. The couple must undergo IVF procedures to generate embryos in vitro. The embryos can be biopsied at either the zygote, cleavage or blastocyst stage. Preimplantation genetic screening uses the same technology to screen for chromosome abnormalities in embryos from patients undergoing IVF procedures as a method of embryo selection. Fluorescence in-situ hybridization was originally used for chromosome analysis, but has now been replaced by array comparative genomic hybridization or next generation sequencing. For the diagnosis of single gene defects, polymerase chain reaction is used and has become highly developed; however, single nucleotide polymorphism arrays for karyomapping have recently been introduced. A partnership between IVF laboratories and diagnostic centres is required to carry out PGD and preimplantation genetic screening. Accreditation of PGD diagnostic laboratories is important. Accreditation gives IVF centres an assurance that the diagnostic tests conform to specified standards. ISO 15189 is an international laboratory standard specific for medical laboratories. A requirement for accreditation is to participate in external quality assessment schemes. PMID:26776824

  18. Nuclear Technology Series. Course 14: Introduction to Quality Assurance/Quality Control.

    ERIC Educational Resources Information Center

    Technical Education Research Center, Waco, TX.

    This technical specialty course is one of thirty-five courses designed for use by two-year postsecondary institutions in five nuclear technician curriculum areas: (1) radiation protection technician, (2) nuclear instrumentation and control technician, (3) nuclear materials processing technician, (4) nuclear quality-assurance/quality-control…

  19. Quality Assurance and Quality Control Practices for Rehabilitation of Sewer and Water Mains

    EPA Science Inventory

    As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued, including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of reha...

  20. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    EPA Science Inventory

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  1. Development and Testing of a Nuclear Quality Assurance/Quality Control Technician Curriculum. Final Report.

    ERIC Educational Resources Information Center

    Espy, John; And Others

    A project was conducted to field test selected first- and second-year courses in a postsecondary nuclear quality assurance/quality control (QA/QC) technician curriculum and to develop the teaching/learning modules for seven technical specialty courses remaining in the QA/QC technician curriculum. The field testing phase of the project involved the…

  2. Quality Assurance and Quality Control Practices For Rehabilitation of Sewer and Water Mains

    EPA Science Inventory

    As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of rehab...

  3. Quality control throughout the production process of infant food.

    PubMed

    Hamrin, Pia; Hoeft, Birgit

    2012-01-01

    The manufacture of infant food is a highly complex process and needs an effective quality control beyond classical in-process parameters and a final microbiological analysis. To ensure a safe end -product, various tools, such as the Hazard Analysis Critical Control Points (HACCP), have been developed to facilitate the management of food safety. Every single infant formula ingredient must have an excellent quality and safety approach because even if an ingredient is used in very small quantities in a single product, serious consequences may arise if the quality and product safety are not taken seriously by the ingredient manufacturer. The purpose of this article was twofold: firstly, to briefly describe existing Quality Management Systems and, secondly, to highlight the consequences of non-quality. PMID:22699770

  4. The process of managerial control in quality improvement initiatives.

    PubMed

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs. PMID:10138526

  5. Advanced Quality Control System for the Thermomechanical Pulping Process Improves Quality and Reduces Energy Costs for Augusta Newsprint

    SciTech Connect

    Not Available

    2002-02-01

    In July 2001, the Augusta Newsprint Company partnered with Invensys' Pacific Simulation group to implement an advanced quality control (AQC) solution for the thermomechanical pulping (TMP) process at Augusta Newsprint's Augusta, Georgia, site. The goal of the project is to decrease energy and raw material costs while maintaining final pulp quality. The project involves coordinating AQC in 3 areas of the paper mill to reduce the amount of energy required for manufacturing. In addition, a time-of-day production (TODP) feature will use current power market pricing data to adjust production rates in the pulping operation to minimize the average cost of purchased energy. The AQC implementation is currently in progress.

  6. Genetic Control of Meat Quality Traits

    NASA Astrophysics Data System (ADS)

    Williams, John L.

    Meat was originally produced from non-specialized animals that were used for a variety of purposes, in addition to being a source of food. However, selective breeding has resulted in “improved” breeds of cattle that are now used to produce either milk or beef, and specialized chicken lines that produce eggs or meat. These improved breeds are very productive under appropriate management systems. The selection methods used to create these specialized breeds were based on easily measured phenotypic variations, such as growth rate or physical size. Improvement in the desired trait was achieved by breeding directly from animals displaying the desired phenotype. However, more recently sophisticated genetic models have been developed using statistical approaches that consider phenotypic information collected, not only from individual animals but also from their parents, sibs, and progeny.

  7. Research review: Indoor air quality control techniques

    SciTech Connect

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs.

  8. [Our experience with outside laboratory quality control].

    PubMed

    Dochev, D; Arakasheva, V; Nashkov, A; Tsachev, K

    1979-01-01

    The results from the national outside laboratory qualitative control of the clinical diagnostic laboratory investigations for the period September 1975 -- May 1977 were described. The following interlaboratory discrepancy was found on base of a systematic analysis of the data from the last two ring-like check-ups, November 1976 and May 1977, exressed by the variation coefficient (V.C. %); total protein, sodium, potassium and chlorides -- under 10%; cholesterol, urea and total fats -- between 10 and 20%; calcium, phosphorus, iron and creatinine -- over 20%. The highest per cent of admissible results are found with total protein -- to 85%; cholesterol -- to 70.38%; glucosa -- to 73.17%, urea -- to 69.23%, potassium -- to 59.46%, chlorides -- to 57.9%. With sodium, phosphorus, calcium, iron creatinine and uric acid the "admissibility" fluctuates about or under 50 per cent. The values of the qualitative-control indices discussed are comparable with the values obtained from them in the interlaboratory comparisons of other countries. PMID:494628

  9. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving...

  10. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2....

  11. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2....

  12. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false What must quality control personnel do? 111.105... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must... manufacturing record. To do so, quality control personnel must perform operations that include: (a) Approving...

  13. Health care reform: will quality remodeling affect obstetrician-gynecologists in addition to patients?

    PubMed

    von Gruenigen, Vivian E; Deveny, T Clifford

    2011-05-01

    The Patient Protection and Affordable Care Act is a federal statute that attempts to address many fundamental problems with the current health care system including the uninsured, rising health care costs, and quality care. Quality metrics have been in development for years (by private and governmental sectors), and momentum is growing. The purpose of this commentary is to explore quality changes in the way practicing obstetricians and gynecologists will be held accountable for quality service. Two new options being explored for health care, both focusing on improving quality and physician metrics, include value-based purchasing and accountable-care organizations. Both will likely consist of universal clinical algorithms and cost monitoring as measures. For obstetrics this will probably include physician's rates of cesarean deliveries and elective inductions. For gynecology this may comprise of indications for hysterectomy with documented failed medical management, minor surgical management, or both medical and minor surgical management. It is anticipated patients will no longer be able to request obstetric testing, pregnancy induction, or hysterectomy. It is imperative we, as obstetrician-gynecologists, are involved in health care reform that inevitably involves the care of women. The expectation is that the American Congress of Obstetricians and Gynecologists (ACOG) will further develop evidenced-based opinions and guidelines, as medical communities embrace ACOG documents and reference these in hospital policies and peer review. PMID:21508757

  14. Statistical Process Control: Going to the Limit for Quality.

    ERIC Educational Resources Information Center

    Training, 1987

    1987-01-01

    Defines the concept of statistical process control, a quality control method used especially in manufacturing. Generally, concept users set specific standard levels that must be met. Makes the point that although employees work directly with the method, management is responsible for its success within the plant. (CH)

  15. Silicon Sheet Quality is Improved By Meniscus Control

    NASA Technical Reports Server (NTRS)

    Yates, D. A.; Hatch, A. E.; Goldsmith, J. M.

    1983-01-01

    Better quality silicon crystals for solar cells are possible with instrument that monitors position of meniscus as sheet of solid silicon is drawn from melt. Using information on meniscus height, instrument generates feedback signal to control melt temperature. Automatic control ensures more uniform silicon sheets.

  16. CRN5EXP: Expert system for statistical quality control

    NASA Technical Reports Server (NTRS)

    Hentea, Mariana

    1991-01-01

    The purpose of the Expert System CRN5EXP is to assist in checking the quality of the coils at two very important mills: Hot Rolling and Cold Rolling in a steel plant. The system interprets the statistical quality control charts, diagnoses and predicts the quality of the steel. Measurements of process control variables are recorded in a database and sample statistics such as the mean and the range are computed and plotted on a control chart. The chart is analyzed through patterns using the C Language Integrated Production System (CLIPS) and a forward chaining technique to reach a conclusion about the causes of defects and to take management measures for the improvement of the quality control techniques. The Expert System combines the certainty factors associated with the process control variables to predict the quality of the steel. The paper presents the approach to extract data from the database, the reason to combine certainty factors, the architecture and the use of the Expert System. However, the interpretation of control charts patterns requires the human expert's knowledge and lends to Expert Systems rules.

  17. Highly Diastereoselective Chelation-controlled Additions to α-Silyloxy Ketones

    PubMed Central

    Stanton, Gretchen R.; Koz, Gamze

    2011-01-01

    The polar Felkin-Anh, Cornforth, and Cram-chelation models predict that the addition of organometallic reagents to silyl–protected α–hydroxy ketones proceeds via a non-chelation pathway to give anti-diol addition products. This prediction has held true for the vast majority of additions reported in the literature and few methods for chelation-controlled additions of organometallic reagents to silyl–protected α–hydroxy ketones have been introduced. Herein, we present a general and highly diastereoselective method for the addition of dialkylzincs and (E)-di-, (E)-tri- and (Z)-disubstituted vinylzinc reagents to α-silyloxy ketones using alkyl zinc halide Lewis acids, RZnX, to give chelation-controlled products (dr ≥18:1). The compatibility of organozinc reagents with other functional groups makes this method potentially very useful in complex molecule synthesis. PMID:21534530

  18. Rheological parameters of dough with inulin addition and its effect on bread quality

    NASA Astrophysics Data System (ADS)

    Bojnanska, T.; Tokar, M.; Vollmannova, A.

    2015-04-01

    The rheological properties of enriched flour prepared with an addition of inulin were studied. The addition of inulin caused changes of the rheological parameters of the recorder curve. 10% and more addition significantly extended development time and on the farinogram were two peaks of consistency, what is a non-standard shape. With increasing addition of inulin resistance to deformation grows and dough is difficult to process, over 15% addition make dough short and unsuitable for making bread. Bread volume, the most important parameter, significantly decreased with inulin addition. Our results suggest a level of 5% inulin to produce a functional bread of high sensory acceptance and a level of 10% inulin produce a bread of satisfactory sensory acceptance. Bread with a level over 10% of inulin was unsatisfactory.

  19. Designing in quality through design control: a manufacturer's perspective.

    PubMed

    Lasky, F D; Boser, R B

    1997-05-01

    Quality by design is a comprehensive program that begins with understanding user needs and continues through (but does not end with) monitoring customer acceptance. Management tools and processes such as ISO 9000 standards and the Food and Drug Administration Quality System Regulations exist to guide medical device manufacturers in quality practices. The goal is to deliver products acceptable for their intended use. Quality control begins with defining attributes ranging from color to accuracy and precision. Failure mode and effects analysis and risk analysis consider both probability and severity of potential malfunctions and their effects on patients or operators. Tools used to implement design and production practices include Program Evaluation and Review Technique (PERT) charts and industry-conceived concepts, such as Six Sigma techniques. Their use varies with manufacturer, depending on product and customer needs and the manufacturer's specific quality practices. Verification confirms that input goals are met. Then, validation assures that intended clinical needs are continually satisfied by establishing adequate production specifications. Conformance is monitored to verify that stable, consistent processes are in place, and precise user instructions enable the device to satisfy its intended use. Finally, complaint tracking can help assess whether needs have been met. Modifications in service, hardware, or instructions (including quality control) might be required. Therefore, both manufacturers and users work in partnership for continual improvement. The manufacturer's knowledge of design, production, and service needs of its devices enable it to recommend appropriate quality-control protocols for clinical testing. PMID:9166255

  20. Quality control loop for 3D laser beam cutting

    NASA Astrophysics Data System (ADS)

    Spitznagel, Juergen

    1996-08-01

    Existing systems for computer integrated manufacturing are based on the principle of the process chain: The product runs through different production sections as design, work planning and manufacturing in a sequential order. The data generated by a production sequence are transferred via interface to the following production sequence. These tightly-packed production sequences leave little scope for responding to quality deviations. This deficit is highlighted particularly in 3D laser cutting processes. In order to achieve an optimum machining result, a series of preliminary tests is required. Quality control loops play an important role in restricting the scope of necessary testing to a minimum. The represented control loop contains a CAD- system to design the workpiece, an offline-programming system to develop working strategies and NC/RC-programs as well as a shop-floor oriented tool to record quality data of the workpiece. The systems are coupled by an integrated product model. The control loop feeds quality data back to Operations Planning in the form of rules for processing strategies and technological data, so that the quality of the production process is enhanced. It is intended to supply optimum process parameters, so that the number of preliminary tests can be reduced. On the other hand the control loop contributes quality enhancement measures which serve as rules for the designers.

  1. Effect of whole linseed addition on meat production and quality of Italian Simmental and Holstein young bulls.

    PubMed

    Corazzin, M; Bovolenta, S; Sepulcri, A; Piasentier, E

    2012-01-01

    The effect of long term dietary linseed addition on performance, carcass characteristics and meat quality of Italian Simmental (IS) and Italian Holstein (HI) young bulls was investigated. Thirty-two animals were assigned to 4 groups following a factorial design: 2 breeds - IS and IH - ×2 diets - containing whole ground linseed (5-8% of DM) and control. IS had greater in vivo performance and carcass characteristics than IH. IS muscle had lower C14:0, C16:0, SFA, higher C18:2n-6 cis, PUFAn-6, PUFA and PUFA/SFA proportion than IH in phospholipids (PL) fraction. Linseed inclusion did not affect animal's performance and carcass characteristics. In muscle PL, linseed increased C20:0, C22:0, C23:0, C20:5n-3 and decreased C20:4n-6, PUFAn-6/n-3, PUFAn-6 concentration. Linseed decreased C14:0, C16:0 proportion in neutral lipids (NL) and increased total PUFAn-3, C18:3n-3 proportions both in NL and PL fraction. However, these differences were relatively low from a quantitative point of view. PMID:21873001

  2. Effect of corn bran as dietary fiber addition on baking and sensory quality

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Development of wholesome and nutritious fiber rich food products with acceptable functional and sensory quality is a major industrial concern, seeking to capture consumer’s interest in healthy and functional foods. Dietary fiber in corn bran is known for its beneficial effects on human health and n...

  3. 75 FR 80066 - Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-21

    ... URBAN DEVELOPMENT Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed.... This Notice also lists the following information: Title of Proposal: Quality Control Requirements for... lenders, since these institutions must also conduct quality control on all loans they originate...

  4. Space Shuttle flying qualities and flight control system assessment

    NASA Technical Reports Server (NTRS)

    Myers, T. T.; Mcruer, D. T.; Johnston, D. E.

    1982-01-01

    This paper reviews issues, data, and analyses relevant to the longitudinal flying qualities of the Space Shuttle in approach and landing. The manual control of attitude and path are first examined theoretically to demonstrate the unconventional nature of the Shuttle's augmented pitch and path response characteristics. The time domain pitch rate transient response criterion used for design of the Shuttle flight control system is examined in context with data from recent flying qualities experiments and operational aircraft. Questions arising from this examination are addressed through comparisons with MIL-F-8785C and other proposed flying qualities criteria which indicate potential longitudinal flying qualities problems. However, it is shown that these criteria, based largely on data from conventional aircraft, may be inappropriate for assessing the Shuttle.

  5. Quality control for diagnostic oral microbiology laboratories in European countries

    PubMed Central

    Rautemaa-Richardson, Riina; der Reijden Wa, Wil A Van; Dahlen, Gunnar; Smith, Andrew J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB) Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135) number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections. PMID:22084647

  6. Nuclear fuel pellet quality control using artificial intelligence techniques

    NASA Astrophysics Data System (ADS)

    Song, Xiaolong

    Inspection of nuclear fuel pellets is a complex and time-consuming process. At present, quality control in the fuel fabrication field mainly relies on human manual inspection, which is essentially a judgement call. Considering the high quality requirement of fuel pellets in the nuclear industry, pellet inspection systems must have a high accuracy rate in addition to a high inspection speed. Furthermore, any inspection process should have a low rejection rate of good pellets from the manufacturer point of view. It is very difficult to use traditional techniques, such as simple image comparison, to adequately perform the inspection process of the nuclear fuel pellet. Knowledge-based inspection and a defect-recognition algorithm, which maps the human inspection knowledge, is more robust and effective. A novel method is introduced here for pellet image processing. Three artificial intelligence techniques are studied and applied for fuel pellet inspection in this research. They are an artificial neural network, fuzzy logic, and the decision tree method. A dynamic reference model is located on each input fuel pellet image. Then, those pixels that belong to the abnormal defect are enhanced with high speed and high accuracy. Next, the content-based features for the defect are extracted from those abno1mal pixels and used in the inspection algorithm. Finally, an automated inspection prototype system---Visual Inspection Studio---which combines machine vision and these three AI techniques, is developed and tested. The experimental results indicate a very successful system with a high potential for on-line automatic inspection process.

  7. Biowaste home composting: experimental process monitoring and quality control.

    PubMed

    Tatàno, Fabio; Pagliaro, Giacomo; Di Giovanni, Paolo; Floriani, Enrico; Mangani, Filippo

    2015-04-01

    Because home composting is a prevention option in managing biowaste at local levels, the objective of the present study was to contribute to the knowledge of the process evolution and compost quality that can be expected and obtained, respectively, in this decentralized option. In this study, organized as the research portion of a provincial project on home composting in the territory of Pesaro-Urbino (Central Italy), four experimental composters were first initiated and temporally monitored. Second, two small sub-sets of selected provincial composters (directly operated by households involved in the project) underwent quality control on their compost products at two different temporal steps. The monitored experimental composters showed overall decreasing profiles versus composting time for moisture, organic carbon, and C/N, as well as overall increasing profiles for electrical conductivity and total nitrogen, which represented qualitative indications of progress in the process. Comparative evaluations of the monitored experimental composters also suggested some interactions in home composting, i.e., high C/N ratios limiting organic matter decomposition rates and final humification levels; high moisture contents restricting the internal temperature regime; nearly horizontal phosphorus and potassium evolutions contributing to limit the rates of increase in electrical conductivity; and prolonged biowaste additions contributing to limit the rate of decrease in moisture. The measures of parametric data variability in the two sub-sets of controlled provincial composters showed decreased variability in moisture, organic carbon, and C/N from the seventh to fifteenth month of home composting, as well as increased variability in electrical conductivity, total nitrogen, and humification rate, which could be considered compatible with the respective nature of decreasing and increasing parameters during composting. The modeled parametric kinetics in the monitored experimental

  8. Conflict Inhibitory Control Facilitates Pretense Quality in Young Preschoolers

    PubMed Central

    Van Reet, Jennifer

    2013-01-01

    The present research explores the role of inhibitory control in young preschoolers’ pretense ability using an ego depletion paradigm. In Experiment 1 (N = 56), children’s pretense ability was assessed either before or after participating in conflict inhibitory control or control tasks, and in Experiment 2 (N = 36), pretense ability was measured after children engaged in either conflict or delay inhibitory control tasks. In both experiments, pretense scores were significantly higher only after engaging in conflict inhibitory control tasks. Further, pretense scores were positively correlated with inhibitory control scores when conflict inhibitory control was not experienced first. This pattern of results suggests that inhibitory control may underlie pretense, and conflict inhibitory control can boost the quality of children’s subsequent pretending. PMID:26074736

  9. Theoretical White Dwarf Spectra via the Internet: Quality Control

    NASA Astrophysics Data System (ADS)

    Ringat, E.; Reindl, N.

    2013-01-01

    The first decade of the Virtual Observatory (VO) built up services and tools for data conservation, handling, processing, analysis, etc. A new challenge in the immensely growing VO in operation is continuous quality control at different authority levels. Here we shed light on various aspects of theoretical white dwarf spectra that are provided via the registered TheoSSA VO service. We present benchmark tests that enable the VO user to judge their quality.

  10. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 18 2013-07-01 2013-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control...

  11. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 18 2012-07-01 2012-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control...

  12. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control...

  13. Additional flow quality measurements in the Langley Research Center 8-Foot Transonic Pressure Tunnel

    NASA Technical Reports Server (NTRS)

    Brooks, J. D.; Stainback, P. C.; Brooks, C. W., Jr.

    1980-01-01

    Additional tests were conducted to further define the disturbance characteristics of the Langley 8-Foot Transonic Pressure Tunnel. Measurements were made in the settling chamber with hot wire probes and in the test section with pressure transducers when various methods were used to choke the flow. In addition to presenting rms values measured at various locations and tunnel condition, autocorrelations and cross correlation data are also presented.

  14. Quality control for exposure assessment in epidemiological studies.

    PubMed

    Bornkessel, C; Blettner, M; Breckenkamp, J; Berg-Beckhoff, G

    2010-08-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly. PMID:20308051

  15. Methods of Statistical Control for Groundwater Quality Indicators

    NASA Astrophysics Data System (ADS)

    Yankovich, E.; Nevidimova, O.; Yankovich, K.

    2016-06-01

    The article describes the results of conducted groundwater quality control. Controlled quality indicators included the following microelements - barium, manganese, iron, mercury, iodine, chromium, strontium, etc. Quality control charts - X-bar chart and R chart - were built. For the upper and the lower threshold limits, maximum permissible concentration of components in water and the lower limit of their biologically significant concentration, respectively, were selected. The charts analysis has shown that the levels of microelements content in water at the area of study are stable. Most elements in the underground water are contained in concentrations, significant for human organisms consuming the water. For example, such elements as Ba, Mn, Fe have concentrations that exceed maximum permissible levels for drinking water.

  16. Phase II simulation evaluation of the flying qualities of two tilt-wing flap control concepts

    NASA Technical Reports Server (NTRS)

    Birckelbaw, Lourdes G.; Corliss, Lloyd D.

    1992-01-01

    A simulation study was initiated to investigate alternative wing and flap controls for tilt-wing aircraft. The initial phase of the study compared the flying qualities of both a conventional (programmed) flap and an innovative geared flap. The second phase of the study, reported in this paper, introduced an alternate method for pilot control of the geared flap and further studied the flying qualities of the programmed flap, and two geared flap configurations. The results showed little difference among the three flap control configurations except during a longitudinal reposition task where the programmed flap configuration was the best. The addition of pitch attitude stabilization greatly enhanced the aircraft handling qualities. This paper describes the tilt-wing aircraft and the flap control concepts, and presents the results of the second simulation experiment.

  17. Online naphazoline quality control by micellar-enhanced spectrofluorimetry.

    PubMed

    Peralta, Cecilia Mariana; Silva, Raúl Alejandro; Fernández, Liliana Patricia; Masi, Adriana Noemí

    2011-01-01

    The aim of this study was to develop a method for online spectrofluorimetric quality control of naphazoline (NPZ) in pharmaceuticals and raw drugs. A combination of a flow-injection analysis (FIA) system with micellar-enhanced fluorescence detection is presented as a powerful alternative for the rapid and sensitive analysis of naphazoline. Since NPZ shows low native fluorescence, the use of an anionic surfactant, such as sodium dodecyl sulphate (SDS), provides a considerable enhancement of fluorescence intensity and the nature of the technique allows a possible and easy adaptation to a FIA system. Using λ(exc) = 280 nm and λ(em) = 326 nm, a good linear relationship (LOL) was obtained in the range 0.003-10 µg mL(-1) with a detection limit (LOD) of 3 × 10(-4) µg mL(-1) (s/n = 3). Parameters related to the nature of the analytical signal and to the FIA manifold were optimized. Satisfactory recoveries were obtained in the analysis of commercial pharmaceutical formulations. The proposed method is simple, accurate and allows for high-speed sampling and considerably shorter analysis times. In addition, it requires inexpensive equipment and reagents and has easy operational conditions and no side effects, thus avoiding environmental pollution through toxic waste. PMID:21538792

  18. An Adaptive Buddy Check for Observational Quality Control

    NASA Technical Reports Server (NTRS)

    Dee, Dick P.; Rukhovets, Leonid; Todling, Ricardo; DaSilva, Arlindo M.; Larson, Jay W.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    An adaptive buddy check algorithm is presented that adjusts tolerances for outlier observations based on the variability of surrounding data. The algorithm derives from a statistical hypothesis test combined with maximum-likelihood covariance estimation. Its stability is shown to depend on the initial identification of outliers by a simple background check. The adaptive feature ensures that the final quality control decisions are not very sensitive to prescribed statistics of first-guess and observation errors, nor on other approximations introduced into the algorithm. The implementation of the algorithm in a global atmospheric data assimilation is described. Its performance is contrasted with that of a non-adaptive buddy check, for the surface analysis of an extreme storm that took place in Europe on 27 December 1999. The adaptive algorithm allowed the inclusion of many important observations that differed greatly from the first guess and that would have been excluded on the basis of prescribed statistics. The analysis of the storm development was much improved as a result of these additional observations.

  19. PACS 2000: quality control using the task allocation chart

    NASA Astrophysics Data System (ADS)

    Norton, Gary S.; Romlein, John R.; Lyche, David K.; Richardson, Ronald R., Jr.

    2000-05-01

    Medical imaging's technological evolution in the next century will continue to include Picture Archive and Communication Systems (PACS) and teleradiology. It is difficult to predict radiology's future in the new millennium with both computed radiography and direct digital capture competing as the primary image acquisition methods for routine radiography. Changes in Computed Axial Tomography (CT) and Magnetic Resonance Imaging (MRI) continue to amaze the healthcare community. No matter how the acquisition, display, and archive functions change, Quality Control (QC) of the radiographic imaging chain will remain an important step in the imaging process. The Task Allocation Chart (TAC) is a tool that can be used in a medical facility's QC process to indicate the testing responsibilities of the image stakeholders and the medical informatics department. The TAC shows a grid of equipment to be serviced, tasks to be performed, and the organization assigned to perform each task. Additionally, skills, tasks, time, and references for each task can be provided. QC of the PACS must be stressed as a primary element of a PACS' implementation. The TAC can be used to clarify responsibilities during warranty and paid maintenance periods. Establishing a TAC a part of a PACS implementation has a positive affect on patient care and clinical acceptance.

  20. Performance and quality control of Clear-PEM detector modules

    NASA Astrophysics Data System (ADS)

    Amaral, Pedro; Carriço, Bruno; Ferreira, Miguel; Moura, Rui; Ortigão, Catarina; Rodrigues, Pedro; Da Silva, José C.; Trindade, Andreia; Varela, João

    2007-10-01

    Clear-PEM is a dedicated PET scanner for breast and axilla cancer diagnosis, under development within the framework of the Crystal Clear Collaboration at CERN, aiming at the detection of tumors down to 2 mm in diameter. The camera consists of two planar detector heads with active dimensions 16.0×14.5 cm 2. Each head has 96 Clear-PEM detector modules consisting of 32 LYSO:Ce pixels with dimensions 2×2×20 mm 3 packed in a 4×8 BaSO 4 reflector matrix compressed between two Hamamatsu S8550 APD arrays in a double-readout configuration for Depth-of-Interaction (DoI) determination. The modules are individually measured and characterized before being grouped into Supermodules (comprised of 24 modules). Measured properties include photo-peak position, relative gain dispersion, energy resolution, cross-talk and DoI resolution. Optical inspection of matrices was also performed with the aid of a microscope, to search for pixel misalignments and matrix defects. Modules' performance was thoroughly evaluated with a 511 keV collimated beam to exactly determine DoI resolution. In addition, a fast quality control (QC) procedure using flood irradiations from a 137Cs source was applied systematically. The overall performance of the 24 detector modules complies with the design goals of the Clear-PEM detector, showing energy resolution around 15%, DoI resolution of about 2 mm and gain dispersion among pixels of 15%.

  1. Antagonistic control of a dual-input mammalian gene switch by food additives

    PubMed Central

    Xie, Mingqi; Ye, Haifeng; Hamri, Ghislaine Charpin-El; Fussenegger, Martin

    2014-01-01

    Synthetic biology has significantly advanced the design of mammalian trigger-inducible transgene-control devices that are able to programme complex cellular behaviour. Fruit-based benzoate derivatives licensed as food additives, such as flavours (e.g. vanillate) and preservatives (e.g. benzoate), are a particularly attractive class of trigger compounds for orthogonal mammalian transgene control devices because of their innocuousness, physiological compatibility and simple oral administration. Capitalizing on the genetic componentry of the soil bacterium Comamonas testosteroni, which has evolved to catabolize a variety of aromatic compounds, we have designed different mammalian gene expression systems that could be induced and repressed by the food additives benzoate and vanillate. When implanting designer cells engineered for gene switch-driven expression of the human placental secreted alkaline phosphatase (SEAP) into mice, blood SEAP levels of treated animals directly correlated with a benzoate-enriched drinking programme. Additionally, the benzoate-/vanillate-responsive device was compatible with other transgene control systems and could be assembled into higher-order control networks providing expression dynamics reminiscent of a lap-timing stopwatch. Designer gene switches using licensed food additives as trigger compounds to achieve antagonistic dual-input expression profiles and provide novel control topologies and regulation dynamics may advance future gene- and cell-based therapies. PMID:25030908

  2. A multiple objective optimization approach to quality control

    NASA Technical Reports Server (NTRS)

    Seaman, Christopher Michael

    1991-01-01

    The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios

  3. Results of a quality control on non-interventional studies

    PubMed Central

    Wörz, Karl; Hundt, Ferdinand

    2011-01-01

    Non-interventional studies (NIS) have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM) on the execution of non interventional (observational) studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP), with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies]) – Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut) on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres. This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials. PMID:21863135

  4. Results of a quality control on non-interventional studies.

    PubMed

    Wörz, Karl; Hundt, Ferdinand

    2011-01-01

    Non-interventional studies (NIS) have for decades been an established part of post-authorisation medicinal research. As early as the mid-nineties, there were at least rudimentary demands for controllable data quality. Beginning with the recommendations of the Federal Institute for Drugs and Medical Devices (BfArM) on the execution of non interventional (observational) studies of 1998 and finally with the guidelines and recommendations for ensuring Good Epidemiological Practice (GEP), with the VFA (Verband der forschenden Arzneimittelhersteller [German Association of Research-Based Pharmaceutical Companies]) - Recommendations for the Improvement of Quality and Transparency of NIS and the joint recommendations of BfArM and PEI (Paul-Ehrlich-Institut) on the execution of NIS, pharmaceutical companies are required to monitor and/or verify quality in the course of a project. According to a survey of pharmaceutical companies 2010, about one third of the companies surveyed to date carry out such quality controls on site, at participating study centres. This report deals with the results of such quality control measures in 4 completed projects. The control rates defined in the respective cohort study plans, the measures carried out on site and any consequent measures, such as adjustment of forms, reduction of consultation time and necessary organisational changes are described. A high level of agreement between the data collected and the original patient documents is found, comparable to that in clinical trials. PMID:21863135

  5. Possible approaches to fast quality control of IFE targets

    NASA Astrophysics Data System (ADS)

    Koresheva, E. R.; Nikitenko, A. I.; Aleksandrova, I. V.; Bazdenkov, S. V.; Belolipetskiy, A. A.; Chtcherbakov, V. I.; Osipov, I. E.

    2006-11-01

    In recent years, research into the development of reliable methods and techniques for characterization and quality control of ICF/IFE targets has been carried out very actively. This is motivated by the need to provide the means for precise and accurate knowledge of cryogenic target parameters. On the other hand, particular emphasis should be paid to the fact that fuelling of a commercial power plant requires ~6 targets each second. This indicates that the development of fast quality control techniques is of critical importance as well. Therefore, in this report we discuss the issues underlying the construction of different algorithms for characterization and quality control of ICF/IFE targets. Among them are: (a) algorithm banks and their structure, (b) algorithm testing, (c) target reconstruction experiments. The algorithm bank incorporates the algorithms for two stages of target production: the stage of fuel layering technique development (motionless target) and the stage of cryogenic target delivery (injected target). In the first case an inverse algorithm for individual target characterization (3D target reconstruction) and two threshold algorithms for fast control of target quality are presented. They are based on tomographic information processing methods. Experimentally, tomographic data acquisition is carried out by a hundred projections microtomograph. The spatial resolution of the optical system of the microtomograph is 1 µm for 490 nm wavelength, the accuracy of target angular positioning is ±1.5-2.5 min. In the second case we describe the algorithm based on Fourier transform holography for ultra fast target characterization during its injection. The performed computer experiments have demonstrated much promise of this approach in the following directions: recognition of the target imperfections in both low- and high- harmonics; quality control of both a single target and a target batch; simultaneous control of both an injected target quality and its

  6. Exercise Training Restores Cardiac Protein Quality Control in Heart Failure

    PubMed Central

    Campos, Juliane C.; Queliconi, Bruno B.; Dourado, Paulo M. M.; Cunha, Telma F.; Zambelli, Vanessa O.; Bechara, Luiz R. G.; Kowaltowski, Alicia J.; Brum, Patricia C.; Mochly-Rosen, Daria; Ferreira, Julio C. B.

    2012-01-01

    Exercise training is a well-known coadjuvant in heart failure treatment; however, the molecular mechanisms underlying its beneficial effects remain elusive. Despite the primary cause, heart failure is often preceded by two distinct phenomena: mitochondria dysfunction and cytosolic protein quality control disruption. The objective of the study was to determine the contribution of exercise training in regulating cardiac mitochondria metabolism and cytosolic protein quality control in a post-myocardial infarction-induced heart failure (MI-HF) animal model. Our data demonstrated that isolated cardiac mitochondria from MI-HF rats displayed decreased oxygen consumption, reduced maximum calcium uptake and elevated H2O2 release. These changes were accompanied by exacerbated cardiac oxidative stress and proteasomal insufficiency. Declined proteasomal activity contributes to cardiac protein quality control disruption in our MI-HF model. Using cultured neonatal cardiomyocytes, we showed that either antimycin A or H2O2 resulted in inactivation of proteasomal peptidase activity, accumulation of oxidized proteins and cell death, recapitulating our in vivo model. Of interest, eight weeks of exercise training improved cardiac function, peak oxygen uptake and exercise tolerance in MI-HF rats. Moreover, exercise training restored mitochondrial oxygen consumption, increased Ca2+-induced permeability transition and reduced H2O2 release in MI-HF rats. These changes were followed by reduced oxidative stress and better cardiac protein quality control. Taken together, our findings uncover the potential contribution of mitochondrial dysfunction and cytosolic protein quality control disruption to heart failure and highlight the positive effects of exercise training in re-establishing cardiac mitochondrial physiology and protein quality control, reinforcing the importance of this intervention as a non-pharmacological tool for heart failure therapy. PMID:23300764

  7. Control of terahertz emission in photoconductive antennas through an additional optical continuous wave.

    PubMed

    Bockelt, A; Palací, J; Vidal, B

    2013-08-15

    The manipulation of the operating conditions of photoconductive antennas by means of an additional continuous wave (CW) is reported. It is used to control a fiber-based terahertz (THz) time-domain-spectroscopy system at telecom wavelengths. The injection of an optical CW into the transmitter allows the control of the THz amplitude without causing major degradation to the system performance. This, for instance, can be exploited to perform modulation of the THz signal. PMID:24104665

  8. [Internal quality control for antimicrobial susceptibility test: an experience feedback].

    PubMed

    Vedy, Serge

    2012-01-01

    Internal quality control (IQC) position in antimicrobial susceptibility testing must be evaluated attentively before using. Ours S. aureus ATCC 25923 use during year 2011 has given precious information that can be useful for other laboratories. First, IQC should never be used before checking that all the realisation process steps are controlled. It will then appear that reagents are the most susceptible to give false results. That's what happens in 2.74% of antimicrobial susceptibility test. IQC is then useful to limit their clinical's impact. However, IQC use also shows that quality improvement will be difficult without industrial producer's involvement. PMID:22826843

  9. Annual Technol Conference Transactions - American Society for Quality Control, 34th: Quality in the New Decade, 1980

    SciTech Connect

    Not Available

    1980-05-01

    The conference transactions contain 129 papers dealing with such QC topics as: computer aided QC; metrology; human factors, risk, and product liability law; QC in food processing; statistical technique; quality costs principle; food, drug, and cosmetics; energy; automotive; metals; quality cost and startegic planning; quality motivation; textile and needle trades; environmental quality assurance; biomedical; service industry quality costs; application of quality circles; electronics; advanced reliability techniques; management; aerospace and defense planning and systems; small business quality control inspection; and reliability applications.

  10. [Study thought of pharmaceutical preparations quality standards by dynamic quality control technology].

    PubMed

    Yu, Dan-Hong; Mao, Chen-Mei; Lv, Cheng-Zhe; Jin, Hui-Zhen; Yao, Xin; Jia, Xiao-Bin

    2014-07-01

    Pharmaceutical preparations, particularly as a "secret recipe" of traditional Chinese medicine in medical institutions, are the product of China's medical and health industry, and they are also an important means of competing of different medical institutions. Although pharmaceutical preparations have advantages and characteristics than institutes for drug and pharmaceutical companies, the quality standards of pharmaceutical preparations in medical institutions has not reached the desired level over the years. As we all know, the quality of pharmaceutical preparations is important to ensure the efficacy, especially under the environment of people pay more sttention on drug safety and effectiveness and contry increase emphasis on the stste of pharmaceutical preparations. In view of this, we will improve the grade, stability, and clinical efficacy of pharmaceutical preparations by the advanced equipment, testing instruments and the process dynamic quality control technology. Finally, we hope we can provide new ideas for the quality control of pharmaceutical preparations. PMID:25272516

  11. Molecular aspects of aromatic C additions to soils: Implications of biochar quality for ecosystem functionality

    EPA Science Inventory

    Solid residues of incomplete combustion (biochar or char) are continuously being added to soils due to natural vegetation fires in many ecosystems. However, new strategies for carbon sequestration in soils are likely to include the active addition of biochar to soils. Since bioc...

  12. Addition of glucose oxidase for the improvement of refrigerated dough quality

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Refrigerated dough encompasses a wide range of products and is a very popular choice for consumers. Two of the largest problems that occur during refrigerated dough storage are dough syruping and loss of dough strength. The goal of this study was to evaluate glucose oxidase as an additive to refri...

  13. Effect of a phytogenic feed additive on performance, ovarian morphology, serum lipid parameters and egg sensory quality in laying hen

    PubMed Central

    Saki, Ali Asghar; Aliarabi, Hassan; Hosseini Siyar, Sayed Ali; Salari, Jalal; Hashemi, Mahdi

    2014-01-01

    This present study was conducted to evaluate the effects of dietary inclusion of 4, 8 and 12 g kg-1 phytogenic feed additives mixture on performance, egg quality, ovary parameters, serum biochemical parameters and yolk trimethylamine level in laying hens. The results of experiment have shown that egg weight was increased by supplementation of 12 g kg-1 feed additive whereas egg production, feed intake and feed conversion ratio (FCR) were not significantly affected. There were no significant differences in egg quality parameters by supplementation of phytogenic feed additive, whereas yolk trimethylamine level was decreased as the feed additive level increased. The sensory evaluation parameters did not differ significantly. No significant differences were found in serum cholesterol and triglyceride levels between the treatments but low- and high-density lipoprotein were significantly increased. Number of small follicles and ovary weight were significantly increased by supplementation of 12 g kg-1 feed additive. Overall, dietary supplementation of polyherbal additive increased egg weigh, improved ovary characteristics and declined yolk trimethylamine level. PMID:25610580

  14. 40 CFR 52.1163 - Additional control measures for East Boston.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Boston. 52.1163 Section 52.1163 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Additional control measures for East Boston. (a) On or before December 31, 1975, the Governor, the Mayor of the City of Boston, the Chairman of the Massachusetts Bay Transportation Authority, the Chairman...

  15. 40 CFR 52.1163 - Additional control measures for East Boston.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Boston. 52.1163 Section 52.1163 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Additional control measures for East Boston. (a) On or before December 31, 1975, the Governor, the Mayor of the City of Boston, the Chairman of the Massachusetts Bay Transportation Authority, the Chairman...

  16. 40 CFR 52.1163 - Additional control measures for East Boston.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Boston. 52.1163 Section 52.1163 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Additional control measures for East Boston. (a) On or before December 31, 1975, the Governor, the Mayor of the City of Boston, the Chairman of the Massachusetts Bay Transportation Authority, the Chairman...

  17. 40 CFR 52.1163 - Additional control measures for East Boston.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Boston. 52.1163 Section 52.1163 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Additional control measures for East Boston. (a) On or before December 31, 1975, the Governor, the Mayor of the City of Boston, the Chairman of the Massachusetts Bay Transportation Authority, the Chairman...

  18. Chill water additive controls transfer of Salmonella and Campylobacter by improved chlorine efficacy

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In earlier work, we showed that a proprietary additive (T-128) maintains chlorine activity in the presence of organic material such as broiler parts. T-128 improves the efficacy of chlorine to control transfer of Campylobacter and Salmonella from inoculated wings to un-inoculated wings during immer...

  19. [Physician-independent quality control of health services].

    PubMed

    Hess, Rainer

    2007-01-01

    Currently a physician-independent control of health services can only be managed by means of liability case law. Usually, claims are settled years after the service has been provided, based, though, on medical guidelines that have been established by the medical profession itself at the time of the provision of services. An essential factor in medical quality assurance (QA) is the involvement of the relevant physicians, which should be combined with external controls. Regarding quality in medicine, personal qualification will have to be distinguished from institutional quality and quality of healthcare, which should be ensured by internal and external QA. There is increasing pressure to publish QA results in an institution-related manner. However, the publication of results may lead to the unequal treatment of hospitals, as external QA includes only a limited number of indications (possible misjudgement of overall quality), and refers to different patient populations (no comparable treatment results). However, the publication of such outcome data will prevail in the long-term. The future vision of an external QA system comprises: 1. electronically based patient files and, derived thereof, pseudonymised data sets for QA; 2. IQWiG's participation in the definition of evidence-based indicators for quality assessment as well as the application of these indicators; 3. the full publication of results on an Internet platform. PMID:17711259

  20. Integrated evolutionary computation neural network quality controller for automated systems

    SciTech Connect

    Patro, S.; Kolarik, W.J.

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  1. Process and quality verification controls for solid propellant manufacturing

    NASA Technical Reports Server (NTRS)

    Rogers, C. J.

    1983-01-01

    It is pointed out that in-process tests to verify quality and detect discrepant propellant which could compromise motor performance are essential elements of the solid composite propellant manufacturing process. The successful performance of the 260SL-1 and 260SL-2 motors aptly verified the controls used for manufacturing the propellant. The present investigation is concerned with the selected control parameters, and their relationships to composition and final propellant properties. Control performance is evaluated by comparison with processing data experienced in the manufacture of the propellant for the 260SL-1 motor. It is found that the in-process quality verification controls utilized in the propellant manufacturing process for the 260-in. diameter motor contributed significantly to the confidence of successful and predictable motor performance.

  2. The quality of randomized controlled trials in major anesthesiology journals.

    PubMed

    Greenfield, Mary Lou V H; Rosenberg, Andrew L; O'Reilly, Michael; Shanks, Amy M; Sliwinski, Michelle J; Nauss, Michael D

    2005-06-01

    Increased attention has been directed at the quality of randomized controlled trials (RCTs) and how they are being reported. We examined leading anesthesiology journals to identify if there were specific areas for improvement in the design and analysis of published clinical studies. All RCTs that appeared between January 2000 and December 2000 in leading anesthesiology journals (Anesthesiology,Anesthesia & Analgesia,Anaesthesia, and Canadian Journal of Anaesthesia) were retrieved by a MEDLINE search. We used a previously validated assessment tool, including 14 items associated with study quality, to determine a quality score for each article. The overall mean weighted quality score was 44% +/- 16%. Overall average scores were relatively high for appropriate controls (77% +/- 7%) and discussions of side effects (67% +/- 6%). Scores were very low for randomization blinding (5% +/- 2%), blinding observers to results (1% +/- 1%), and post-beta estimates (16% +/- 13%). Important pretreatment clinical predictors were absent in 32% of all studies. Significant improvement in the reporting and conduct of RCTs is required and should focus on randomization methodology, the blinding of investigators, and sample size estimates. Repeat assessments of the literature may improve the adoption of guidelines for the improvement of the quality of randomized controlled trials. PMID:15920210

  3. Flying qualities and control system characteristics for superaugmented aircraft

    NASA Technical Reports Server (NTRS)

    Myers, T. T.; Mcruer, D. T.; Johnston, D. E.

    1984-01-01

    Aircraft-alone dynamics and superaugmented control system fundamental regulatory properties including stability and regulatory responses of the basic closed-loop systems; fundamental high and low frequency margins and governing factors; and sensitivity to aircraft and controller parameters are addressed. Alternative FCS mechanizations, and mechanizational side effects are also discussed. An overview of flying qualities considerations encompasses general pilot operations as a controller in unattended, intermittent and trim, and full-attention regulatory or command control; effective vehicle primary and secondary response properties to pilot inputs and disturbances; pilot control architectural possibilities; and comparison of superaugmented and conventional aircraft path responses for different forms of pilot control. Results of a simple experimental investigation into pilot dynamic behavior in attitude control of superaugmented aircraft configurations with high frequency time laps and time delays are presented.

  4. Shelf Life and Quality Study of Minced Tilapia with Nori and Hijiki Seaweeds as Natural Additives

    PubMed Central

    Ribeiro, Ingridy Simone; Shirahigue, Ligianne Din; Ferraz de Arruda Sucasas, Lia; Anbe, Lika; da Cruz, Pedro Gomes; Gallo, Cláudio Rosa; Carpes, Solange Teresinha; Marques, Marcos José; Oetterer, Marília

    2014-01-01

    The extraction of mechanically separated meat has emerged as an attractive process. However, it increases the incorporation of oxygen and, consequently, of flavors due to rancidity. Thus, preservatives must be added. The objective of this study was to evaluate the shelf life of minced tilapia to replace synthetic preservatives with Hijiki and Nori seaweeds extracts. The application of the extracts had no effect on the chemical composition of the minced tilapia. The seaweed extracts had inhibitory effect on total volatile base nitrogen. The minced tilapia complied with the microbiological standard set by Brazilin law. The panelists detected no differences in the rancid aroma and only minor differences were detected in the color of the products. It can be concluded that the minced tilapia with added seaweed extracts were within quality standards during frozen storage. PMID:25478593

  5. Shelf life and quality study of minced tilapia with Nori and Hijiki seaweeds as natural additives.

    PubMed

    Ribeiro, Ingridy Simone; Shirahigue, Ligianne Din; Ferraz de Arruda Sucasas, Lia; Anbe, Lika; da Cruz, Pedro Gomes; Gallo, Cláudio Rosa; Carpes, Solange Teresinha; Marques, Marcos José; Oetterer, Marília

    2014-01-01

    The extraction of mechanically separated meat has emerged as an attractive process. However, it increases the incorporation of oxygen and, consequently, of flavors due to rancidity. Thus, preservatives must be added. The objective of this study was to evaluate the shelf life of minced tilapia to replace synthetic preservatives with Hijiki and Nori seaweeds extracts. The application of the extracts had no effect on the chemical composition of the minced tilapia. The seaweed extracts had inhibitory effect on total volatile base nitrogen. The minced tilapia complied with the microbiological standard set by Brazilin law. The panelists detected no differences in the rancid aroma and only minor differences were detected in the color of the products. It can be concluded that the minced tilapia with added seaweed extracts were within quality standards during frozen storage. PMID:25478593

  6. Quality control procedures for genome-wide association studies.

    PubMed

    Turner, Stephen; Armstrong, Loren L; Bradford, Yuki; Carlson, Christopher S; Crawford, Dana C; Crenshaw, Andrew T; de Andrade, Mariza; Doheny, Kimberly F; Haines, Jonathan L; Hayes, Geoffrey; Jarvik, Gail; Jiang, Lan; Kullo, Iftikhar J; Li, Rongling; Ling, Hua; Manolio, Teri A; Matsumoto, Martha; McCarty, Catherine A; McDavid, Andrew N; Mirel, Daniel B; Paschall, Justin E; Pugh, Elizabeth W; Rasmussen, Luke V; Wilke, Russell A; Zuvich, Rebecca L; Ritchie, Marylyn D

    2011-01-01

    Genome-wide association studies (GWAS) are being conducted at an unprecedented rate in population-based cohorts and have increased our understanding of the pathophysiology of complex disease. Regardless of context, the practical utility of this information will ultimately depend upon the quality of the original data. Quality control (QC) procedures for GWAS are computationally intensive, operationally challenging, and constantly evolving. Here we enumerate some of the challenges in QC of GWAS data and describe the approaches that the electronic MEdical Records and Genomics (eMERGE) network is using for quality assurance in GWAS data, thereby minimizing potential bias and error in GWAS results. We discuss common issues associated with QC of GWAS data, including data file formats, software packages for data manipulation and analysis, sex chromosome anomalies, sample identity, sample relatedness, population substructure, batch effects, and marker quality. We propose best practices and discuss areas of ongoing and future research. PMID:21234875

  7. Data quality control in social surveys using genetic information.

    PubMed

    Li, Yi; Guo, Guang

    2014-01-01

    This article introduces a novel way of taking advantage of genetic data in social surveys for the purposes of data quality control. Genetic information could detect and repair data issues such as missing data, reporting errors, differences in measures of the same variable, and flawed data. Using data from two surveys, the College Roommate Study (ROOM) and the National Longitudinal Study of Adolescent Health (Add Health), we show that proportion identical by descent score (a measure of genetic relationships) can identify "misreported" and unreported sibling type and detect misrepresented participants, bio-ancestry score (a measure of ancestral population memberships) can repair and recover missing race and discrepancies among different measures of self-reported race, and sex chromosomal information may help cross-check self-reported sex. This article represents an initial effort to utilize genetic data for the purposes of data quality control. As genetic data become increasingly available, researchers may explore more approaches to improving data quality. PMID:25343368

  8. An engineering approach to controlling indoor air quality.

    PubMed Central

    Woods, J E

    1991-01-01

    Evidence is accumulating that indicates air quality problems in residential and commercial buildings are nearly always associated with inadequacies in building design and methods of operation. Thus, the very systems depended on to control the indoor environment can become indirect sources of contamination if diligence is not exercised at each stage of a building's life: a) planning and design, b) construction and commissioning, c) operation, and d) demolition or renovation. In this paper, an engineering perspective is presented in which the existing building stock is characterized in terms of its environmental performance. Preliminary data indicate that 20 to 30% of the existing buildings have sufficient problems to manifest as sick-building syndrome or building-related illness, while another 10 to 20% may have undetected problems. Thus, only about 50 to 70% of the existing buildings qualify as healthy buildings. Two methods and three mechanisms of control are described to achieve "acceptable" indoor air quality: source control and exposure control. If sources cannot be removed, some level of occupant exposure will result. To control exposures with acceptable values, the primary sensory receptors of the occupants (i.e., thermal, ocular, auditory, and olfactory) cannot be excessively stimulated. The three exposure control mechanisms are conduction, radiation, and convection. To achieve acceptable occupant responses, it is often practical to integrate the mechanisms of radiation and convection in heating, ventilating, and air conditioning systems that are designed to provide acceptable thermal, acoustic, and air quality conditions within occupied spaces.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1821369

  9. FIELD QUALITY CONTROL STRATEGIES ASSESSING SOLIDIFICATION/STABILIZATION

    EPA Science Inventory

    Existing regulatory mobility reduction (leaching) tests are not amenable to real time quality control because of the time required to perform sample extraction and chemical analysis. This is of conccern because the leaching test is the most important parameter used to relate trea...

  10. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Quality control programs. 12.40 Section 12.40 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER POWER PROJECTS...

  11. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Quality control programs. 12.40 Section 12.40 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER POWER PROJECTS...

  12. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Quality control programs. 12.40 Section 12.40 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER POWER PROJECTS...

  13. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control programs. 12.40 Section 12.40 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER POWER PROJECTS...

  14. 18 CFR 12.40 - Quality control programs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Quality control programs. 12.40 Section 12.40 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER POWER PROJECTS...

  15. 30 CFR 28.31 - Quality control plans; contents.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control plans; contents. 28.31 Section 28.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING SHORT-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES...

  16. ACHIEVING IRRIGATION RETURN FLOW QUALITY CONTROL THROUGH IMPROVED LEGAL SYSTEMS

    EPA Science Inventory

    The key to irrigated agricultural return flow quality control is proper utilization and management of the resource itself, and an accepted tool in out society is the law. This project is designed to develop legal alternatives that will facilitate the implementation of improved wa...

  17. On the Need for Quality Control in Validation Research.

    ERIC Educational Resources Information Center

    Maier, Milton H.

    1988-01-01

    Validated aptitude tests used to help make personnel decisions about military recruits against hands-on tests of job performance in radio repairers and automotive mechanics. Data were filled with errors, reducing accuracy of validity coefficients. Discusses how validity coefficients can be made more accurate by exercising quality control during…

  18. Quality Control in Primary Schools: Progress from 2001-2006

    ERIC Educational Resources Information Center

    Hofman, Roelande H.; de Boom, Jan; Hofman, W. H. Adriaan

    2010-01-01

    This article presents findings of research into the quality control (QC) of schools from 2001-2006. In 2001 several targets for QC were set and the progress of 939 primary schools is presented. Furthermore, using cluster analysis, schools are classified into four QC-types that differ in their focus on school (self) evaluation and school…

  19. Quality Control Charts in Large-Scale Assessment Programs

    ERIC Educational Resources Information Center

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  20. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Quality control plans; filing requirements. 28.30 Section 28.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING...

  1. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Quality control plans; filing requirements. 28.30 Section 28.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING...

  2. 30 CFR 28.30 - Quality control plans; filing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Quality control plans; filing requirements. 28.30 Section 28.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS FUSES FOR USE WITH DIRECT CURRENT IN PROVIDING...

  3. Sirt1-deficiency causes defective protein quality control

    PubMed Central

    Tomita, Takuya; Hamazaki, Jun; Hirayama, Shoshiro; McBurney, Michael W.; Yashiroda, Hideki; Murata, Shigeo

    2015-01-01

    Protein quality control is an important mechanism to maintain cellular homeostasis. Damaged proteins have to be restored or eliminated by degradation, which is mainly achieved by molecular chaperones and the ubiquitin-proteasome system. The NAD+-dependent deacetylase Sirt1 has been reported to play positive roles in the regulation of cellular homeostasis in response to various stresses. However, its contribution to protein quality control remains unexplored. Here we show that Sirt1 is involved in protein quality control in both an Hsp70-dependent and an Hsp70-independent manner. Loss of Sirt1 led to the accumulation of ubiquitinated proteins in cells and tissues, especially upon heat stress, without affecting proteasome activities. This was partly due to decreased basal expression of Hsp70. However, this accumulation was only partially alleviated by overexpression of Hsp70 or induction of Hsp70 upon heat shock in Sirt1-deficient cells and tissues. These results suggest that Sirt1 mediates both Hsp70-dependent and Hsp70-independent protein quality control. Our findings cast new light on understanding the role of Sirt1 in maintaining cellular homeostasis. PMID:26219988

  4. Quality control of leather by terahertz time-domain spectroscopy.

    PubMed

    Hernandez-Serrano, A I; Corzo-Garcia, S C; Garcia-Sanchez, E; Alfaro, M; Castro-Camus, E

    2014-11-20

    We use terahertz time-domain spectroscopy, combined with effective-medium theory, to measure the moisture content and thickness of leather simultaneously. These results demonstrate that this method could become a standard quality control test for the industrial tanning process. PMID:25607861

  5. 7 CFR 275.21 - Quality control review reports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Responsibilities for... with Program requirements relative to the Quality Control Review System. Every case selected for review... information contained in the individual case records, or legible copies of that material, as well as...

  6. Summary of beam quality diagnostics and control working group

    SciTech Connect

    Lewellen, John; Piot, Philippe; /Northern Illinois U. /Fermilab

    2006-09-01

    The working group on beam quality, diagnostics, and control at the 12th Advanced Accelerator Concepts Workshop held a series of meetings during the Workshop. The generation of bright charged-particle beams (in particular electron and positron beams), along with state-of-the-art beam diagnostics and synchronization were discussed.

  7. Quality Control through Design and Process: Gambrel Roof Truss Challenge

    ERIC Educational Resources Information Center

    Ward, Dell; Jones, James

    2011-01-01

    Customers determine whether a product fulfills their needs or satisfies them. "Quality control", then, is the process of finding out what the customer wants, along with designing, producing, delivering, and servicing the product--and ultimately satisfying the customer's expectations. For many years, people considered a product to be of good…

  8. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625...

  9. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625...

  10. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625...

  11. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625...

  12. 21 CFR 864.8625 - Hematology quality control mixture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8625...

  13. 7 CFR 275.21 - Quality control review reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 4 2011-01-01 2011-01-01 false Quality control review reports. 275.21 Section 275.21 Agriculture Regulations of the Department of Agriculture (Continued) FOOD AND NUTRITION SERVICE, DEPARTMENT OF AGRICULTURE FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Responsibilities...

  14. DEVELOPMENT OF SUSPENDED SOLIDS QUALITY CONTROL AND PERFORMANCE EVALUATION SAMPLES

    EPA Science Inventory

    A two phase study was conducted to develop a synthetic suspended solids sample for use as quality control check and performance evaluation within environmental monitoring laboratories. The first phase consisted of a feasibility study to determine compounds that exhibited the opti...

  15. HANDBOOK FOR ANALYTICAL QUALITY CONTROL IN WATER AND WASTEWATER LABORATORIES

    EPA Science Inventory

    This handbook is addressed to laboratory directors, leaders of field investigations, and other personnel who bear responsibility for water and wastewater data. Subject matter of the handbook is concerned primarily with quality control (QC) for chemical and biological tests and me...

  16. QUALITY CONTROL FOR ENVIRONMENTAL MEASUREMENTS USING GAMMA-RAY SPECTROMETRY

    EPA Science Inventory

    This report describes the quality control procedures, calibration, collection, analysis, and interpretation of data in measuring the activity of gamma ray-emitting radionuclides in environmental samples. Included in the appendices are basic data for selected gamma ray-emitting ra...

  17. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 4 2012-04-01 2012-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization...

  18. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization...

  19. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 4 2013-04-01 2013-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization...

  20. 21 CFR 211.22 - Responsibilities of quality control unit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 4 2014-04-01 2014-04-01 false Responsibilities of quality control unit. 211.22 Section 211.22 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Organization...

  1. Stochastic Models of Quality Control on Test Misgrading.

    ERIC Educational Resources Information Center

    Wang, Jianjun

    Stochastic models are developed in this article to examine the rate of test misgrading in educational and psychological measurement. The estimation of inadvertent grading errors can serve as a basis for quality control in measurement. Limitations of traditional Poisson models have been reviewed to highlight the need to introduce new models using…

  2. GenePRIMP: A software quality control tool

    SciTech Connect

    Amrita Pati

    2010-05-05

    Amrita Pati of the DOE Joint Genome Institute's Genome Biology group describes the software tool GenePRIMP and how it fits into the quality control pipeline for microbial genomics. Further details regarding GenePRIMP appear in a paper published online May 2, 2010 in Nature Methods.

  3. GenePRIMP: A software quality control tool

    ScienceCinema

    Amrita Pati

    2010-09-01

    Amrita Pati of the DOE Joint Genome Institute's Genome Biology group describes the software tool GenePRIMP and how it fits into the quality control pipeline for microbial genomics. Further details regarding GenePRIMP appear in a paper published online May 2, 2010 in Nature Methods.

  4. Incorporating Quality Control Information in the Sensor Web

    NASA Astrophysics Data System (ADS)

    Devaraju, Anusuriya; Kunkel, Ralf; Bogena, Heye

    2013-04-01

    The rapid development of sensing technologies had led to the creation of large amounts of heterogeneous environmental observations. The Sensor Web provides a wider access to sensors and observations via common protocols and specifications. Observations typically go through several levels of quality control, and aggregation before they are made available to end-users. Raw data are usually inspected, and related quality flags are assigned. Data are gap-filled, and errors are removed. New data series may also be derived from one or more corrected data sets. Until now, it is unclear how these kinds of information can be captured in the Sensor Web Enablement (SWE) framework. Apart from the quality measures (e.g., accuracy, precision, tolerance, or confidence), the levels of observational series, the changes applied, and the methods involved must be specified. It is important that this kind of quality control information is well described and communicated to end-users to allow for a better usage and interpretation of data products. In this paper, we describe how quality control information can be incorporated into the SWE framework. Concerning this, first, we introduce the TERENO (TERrestrial ENvironmental Observatories), an initiative funded by the large research infrastructure program of the Helmholtz Association in Germany. The main goal of the initiative is to facilitate the study of long-term effects of climate and land use changes. The TERENO Online Data RepOsitORry (TEODOOR) is a software infrastructure that supports acquisition, provision, and management of observations within TERENO via SWE specifications and several other OGC web services. Next, we specify changes made to the existing observational data model to incorporate quality control information. Here, we describe the underlying TERENO data policy in terms of provision and maintenance issues. We present data levels, and their implementation within TEODOOR. The data levels are adapted from those used by

  5. Assessing the Quality of Randomized Controlled Urological Trials Conducted by Korean Medical Institutions

    PubMed Central

    Chung, Jae Hoon

    2013-01-01

    Purpose To assess the quality of randomized controlled urological trials conducted by Korean medical institutions. Materials and Methods Quality assessment was conducted by using the Jadad scale; in addition, the van Tulder scale and the Cochrane Collaboration risk of bias tool were used as individual indices. All assessments were performed by two reviewers. If the outcomes differed, the two reviewers and a third reviewer adjusted the discrepancy in the results through discussion. Starting from 1986, a quality analysis of randomized controlled trials (RCTs) was conducted in 1-year and 5-year units. The quality assessment was conducted by subject, type of intervention, presence of double blinding, presence of funding, and review by an Institutional Review Board (IRB). Results Whereas the number of RCTs published has gradually increased, there was no significant difference in the quality of the RCTs according to publication year. Drug studies, double-blind studies, studies with funding, and studies reviewed by IRBs had higher quality scores and a higher percentage of high-quality RCTs than did other studies. Thirty-six RCTs were published in journals included in the Science Citation Index and 20 RCTs were published in journals included in the Science Citation Index Expanded. The largest number of RCTs (32.32%) were published by the Korean Journal of Urology. Conclusions A quantitative increase was observed in RCTs over time, but no qualitative improvement in the RCTs was observed. It seems necessary to put effort into the quality improvement of RCTs at the design stage. PMID:23700493

  6. Investigating friendship quality: an exploration of self-control and social control theories' friendship hypotheses.

    PubMed

    Boman, John H; Krohn, Marvin D; Gibson, Chris L; Stogner, John M

    2012-11-01

    While associations with deviant peers are well understood to impact individual development, less is understood about the relationship between friendship quality and delinquency. Two criminological theories--social control theory and self-control theory--are able to offer an explanation for the latter relationship. Social control and self-control theories both premise that delinquents will have largely fractured, weak, and "cold and brittle" friendships. This study investigates how variations in perceptions of friendship quality are related to the delinquency, maternal attachment, school attachment, and self-control levels of both a participant and his/her close friend. To explore these relationships, we use a diverse (14% black; 18% Hispanic; 9% Asian) sample of 2,154 emerging adults within 1,077 friendship pairs (66% female). In each dyad, both members perceived the friendship's quality and reported personal markers of delinquency, social bonds, and self-control. Several series of multilevel models are estimated that regress each participant's friendship quality perception onto the participant's and their friend's delinquency, attachments, self-control, and demographic characteristics. Results show that delinquents have as intense, or more intense, friendships as non-delinquents. However, low levels of both actor and partner attachments and self-control are independently related to low friendship quality, and this is especially true for self-control. Supplemental analyses demonstrate that the effect of self-control on friendship quality may be reduced when individuals in dyads are delinquent. In conclusion, studies that address friendship quality without including characteristics of multiple members of the friendship are only capturing part of one's estimate of friendship quality. PMID:22367018

  7. Longevity and effectiveness of aluminum addition to reduce sediment phosphorus release and restore lake water quality.

    PubMed

    Huser, Brian J; Egemose, Sara; Harper, Harvey; Hupfer, Michael; Jensen, Henning; Pilgrim, Keith M; Reitzel, Kasper; Rydin, Emil; Futter, Martyn

    2016-06-15

    114 lakes treated with aluminum (Al) salts to reduce internal phosphorus (P) loading were analyzed to identify factors driving longevity of post-treatment water quality improvements. Lakes varied greatly in morphology, applied Al dose, and other factors that may have affected overall treatment effectiveness. Treatment longevity based on declines in epilimnetic total P (TP) concentration averaged 11 years for all lakes (range of 0-45 years). When longevity estimates were used for lakes with improved conditions through the end of measurements, average longevity increased to 15 years. Significant differences in treatment longevity between deeper, stratified lakes (mean 21 years) and shallow, polymictic lakes (mean 5.7 years) were detected, indicating factors related to lake morphology are important for treatment success. A decision tree developed using a partition model suggested Al dose, Osgood index (OI, a morphological index), and watershed to lake area ratio (related to hydraulic residence time, WA:LA) were the most important variables determining treatment longevity. Multiple linear regression showed that Al dose, WA:LA, and OI explained 47, 32 and 3% respectively of the variation in treatment longevity. Other variables (too data limited to include in the analysis) also appeared to be of importance, including sediment P content to Al dose ratios and the presence of benthic feeding fish in shallow, polymictic lakes. PMID:26250754

  8. Investigating Friendship Quality: An Exploration of Self-Control and Social Control Theories' Friendship Hypotheses

    ERIC Educational Resources Information Center

    Boman, John H., IV; Krohn, Marvin D.; Gibson, Chris L.; Stogner, John M.

    2012-01-01

    While associations with deviant peers are well understood to impact individual development, less is understood about the relationship between friendship quality and delinquency. Two criminological theories--social control theory and self-control theory--are able to offer an explanation for the latter relationship. Social control and self-control…

  9. Modular Skeletal Evolution in Sticklebacks Is Controlled by Additive and Clustered Quantitative Trait Loci

    PubMed Central

    Miller, Craig T.; Glazer, Andrew M.; Summers, Brian R.; Blackman, Benjamin K.; Norman, Andrew R.; Shapiro, Michael D.; Cole, Bonnie L.; Peichel, Catherine L.; Schluter, Dolph; Kingsley, David M.

    2014-01-01

    Understanding the genetic architecture of evolutionary change remains a long-standing goal in biology. In vertebrates, skeletal evolution has contributed greatly to adaptation in body form and function in response to changing ecological variables like diet and predation. Here we use genome-wide linkage mapping in threespine stickleback fish to investigate the genetic architecture of evolved changes in many armor and trophic traits. We identify >100 quantitative trait loci (QTL) controlling the pattern of serially repeating skeletal elements, including gill rakers, teeth, branchial bones, jaws, median fin spines, and vertebrae. We use this large collection of QTL to address long-standing questions about the anatomical specificity, genetic dominance, and genomic clustering of loci controlling skeletal differences in evolving populations. We find that most QTL (76%) that influence serially repeating skeletal elements have anatomically regional effects. In addition, most QTL (71%) have at least partially additive effects, regardless of whether the QTL controls evolved loss or gain of skeletal elements. Finally, many QTL with high LOD scores cluster on chromosomes 4, 20, and 21. These results identify a modular system that can control highly specific aspects of skeletal form. Because of the general additivity and genomic clustering of major QTL, concerted changes in both protective armor and trophic traits may occur when sticklebacks inherit either marine or freshwater alleles at linked or possible “supergene” regions of the stickleback genome. Further study of these regions will help identify the molecular basis of both modular and coordinated changes in the vertebrate skeleton. PMID:24652999

  10. Modular skeletal evolution in sticklebacks is controlled by additive and clustered quantitative trait Loci.

    PubMed

    Miller, Craig T; Glazer, Andrew M; Summers, Brian R; Blackman, Benjamin K; Norman, Andrew R; Shapiro, Michael D; Cole, Bonnie L; Peichel, Catherine L; Schluter, Dolph; Kingsley, David M

    2014-05-01

    Understanding the genetic architecture of evolutionary change remains a long-standing goal in biology. In vertebrates, skeletal evolution has contributed greatly to adaptation in body form and function in response to changing ecological variables like diet and predation. Here we use genome-wide linkage mapping in threespine stickleback fish to investigate the genetic architecture of evolved changes in many armor and trophic traits. We identify >100 quantitative trait loci (QTL) controlling the pattern of serially repeating skeletal elements, including gill rakers, teeth, branchial bones, jaws, median fin spines, and vertebrae. We use this large collection of QTL to address long-standing questions about the anatomical specificity, genetic dominance, and genomic clustering of loci controlling skeletal differences in evolving populations. We find that most QTL (76%) that influence serially repeating skeletal elements have anatomically regional effects. In addition, most QTL (71%) have at least partially additive effects, regardless of whether the QTL controls evolved loss or gain of skeletal elements. Finally, many QTL with high LOD scores cluster on chromosomes 4, 20, and 21. These results identify a modular system that can control highly specific aspects of skeletal form. Because of the general additivity and genomic clustering of major QTL, concerted changes in both protective armor and trophic traits may occur when sticklebacks inherit either marine or freshwater alleles at linked or possible "supergene" regions of the stickleback genome. Further study of these regions will help identify the molecular basis of both modular and coordinated changes in the vertebrate skeleton. PMID:24652999

  11. A Simple and Inexpensive Device for Slow, Controlled Addition of a Solution to a Reaction Mixture

    NASA Astrophysics Data System (ADS)

    Osvath, Peter

    1995-07-01

    A number of reactions require the slow and controlled addition of a solution containing one reagent to another. Attempting to control the flow rate over a number of hours using a conventional constant pressure addition funnel is a frustrating exercise; commercially available constant volume addition funnels are expensive and must be adjusted by trial and error each time a reaction is carried out. The use of an (expensive) peristaltic pump or syringe pump overcomes these problems but can introduce other complications. We have recently had occasion to carry out the synthesis of thioether macrocycles and cages requiring the slow and controlled addition of DMF solutions of (offensively odoriferous) thiols or (air-sensitive) thiolates to a reactant solution under nitrogen(1), Although the use of a syringe pump was called for, there are obvious difficulties associated with purging the solution and assembling such an apparatus under nitrogen, and we report a simple and inexpensive solution. A Male Luer Lock tip (recovered from a broken syringe) was sweated onto the flattened tip of a pressure-equalizing addition funnel and a syringe needle was attached. Judicious selection of needle length, bore size, and reactant volume can be used to control the addition time simply and reproducibly. With a 250-mL funnel, the flow rate changes by <25% from the beginning to the end of the addition. (In fact, a reduction in the rate of addition may even be advantageous as the reaction proceeds, the reagent in the receiving flask is consumed, its concentration drops, and the rate of reaction will decrease). A piece of fine Teflon tubing of appropriate length attached to the needle can be used to reduce the flow rate even further, but this is only necessary for very slow rates of addition. For example, the time of addition of 200 mL, of an ethanolic solution could be varied from approximately 5 minutes (150mm/17 gauge) to approximately 5 h (200mm/22 gauge), and once the addition time for a

  12. Manufacture and quality control of interconnecting wire hardnesses, Volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A standard is presented for manufacture, installation, and quality control of eight types of interconnecting wire harnesses. The processes, process controls, and inspection and test requirements reflected are based on acknowledgment of harness design requirements, acknowledgment of harness installation requirements, identification of the various parts, materials, etc., utilized in harness manufacture, and formulation of a typical manufacturing flow diagram for identification of each manufacturing and quality control process, operation, inspection, and test. The document covers interconnecting wire harnesses defined in the design standard, including type 1, enclosed in fluorocarbon elastomer convolute, tubing; type 2, enclosed in TFE convolute tubing lines with fiberglass braid; type 3, enclosed in TFE convolute tubing; and type 5, combination of types 3 and 4. Knowledge gained through experience on the Saturn 5 program coupled with recent advances in techniques, materials, and processes was incorporated.

  13. Soil moisture and strength index for earthwork construction quality control

    NASA Astrophysics Data System (ADS)

    Sawangsuriya, A.; Wachiraporn, S.; Sramoon, W.

    2015-09-01

    This paper presents the implementation of soil moisture and strength index measurements for earthwork construction quality control as well as a link between the in situ testing and structural property of earthen materials. Use of the convenient Dynamic Cone Penetrometer (DCP) in conjunction with conventional moisture-density measurements enhances quality control by achieving acceptable level of compaction, more uniform structural properties, and aids developing a controlled design parameter during the earthwork construction. Soil strength in term of DCP index normalized by the deviation of compaction moisture content from the optimum moisture content is proposed as performance criteria for a variety of engineered earth fills and special engineering assessment, prevention, and mitigation of geohazards e.g. earthen flood defense embankments.

  14. [Quality control of recombinant oncolytic adenovirus/p53].

    PubMed

    Gao, Kai; Bi, Hua; Ding, You-Xue; Li, Yong-Hong; Han, Chun-Mei; Guo, Ying; Rao, Chun-Ming

    2011-12-01

    To establish a detection method of oncolytic adenovirus/p53 and standard of quality control, human telomerase reverse transcriptase (hTERT) promoter, CMV fusion promoter containing hypoxia reaction element (HRE) and p53 gene were identified by vector DNA restriction enzyme digestion and PCR analysis. The result conformed that all modified regions were in consistent with theoretical ones. Particle number was 2.0 x 10(11) mL(-1) determined by UV (A260). Infectious titer was 5.0 x 10(10) IU mL(-1) analyzed by TCID50. In vitro p53 gene expression in human lung cancer cell H1299 was determined by ELISA, and A450 ratio of nucleoprotein in virus infection group to control group was 5.2. Antitumor potency was evaluated by cytotoxicity assay using human lung cancer cell A549, and the MOI(IC50) of this gene therapy preparation was 1.0. The tumor cells targeted replication ability of recombinant virus was determined by TCID50 titer ratio of filial generation virus between human lung cancer cell A549 and human diploid epidermal fibrolast BJ cells after infected by virus with same MOI. TCID50 titer ratio of tumor cell infection group to normal cell infection control group was 398. The IE-HPLC purity of virus was 99.5%. There was less than 1 copy of wild type adenovirus within 1 x 10(7) VP recombinant virus. Other quality control items were complied with corresponding requirements in the guidance for human somatic cell therapy and gene therapy and Chinese pharmacopeia volume III. The detection method of oncolytic adenovirus/p53 was successfully established for quality control standard. The study also provided reference for quality control of other oncolytic viral vector products. PMID:22375422

  15. 21 CFR 111.105 - What must quality control personnel do?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false What must quality control personnel do? 111.105 Section 111.105 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for Quality Control § 111.105 What must quality control personnel do? Quality control personnel...

  16. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  17. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.30 Section 81.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the...

  18. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.44 Section 81.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of...

  19. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.41 Section 81.41 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of...

  20. 40 CFR 81.120 - Middle Tennessee Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.120 Section 81.120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.120 Middle Tennessee Intrastate Air Quality Control Region. The Middle Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed...

  1. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.24 Section 81.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial...

  2. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.16 Section 81.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial...

  3. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.23 Section 81.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the...

  4. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.20 Section 81.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist...

  5. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial...

  6. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.48 Section 81.48 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of...

  7. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION... Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control Region. The Metropolitan Indianapolis Intrastate Air Quality Control Region consists of the...

  8. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.62 Section 81.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the...

  9. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION... Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control Region. The Metropolitan Indianapolis Intrastate Air Quality Control Region consists of the...

  10. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.43 Section 81.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial...

  11. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of...

  12. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  13. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.75 Section 81.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been...

  14. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.43 Section 81.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial...

  15. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson Intrastate Air Quality Control Region has been renamed the Maricopa Intrastate Air Quality Control Region... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Maricopa Intrastate Air...

  16. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.34 Section 81.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  17. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area...

  18. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.16 Section 81.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial...

  19. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.75 Section 81.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been...

  20. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson Intrastate Air Quality Control Region has been renamed the Maricopa Intrastate Air Quality Control Region... 40 Protection of Environment 17 2011-07-01 2011-07-01 false Maricopa Intrastate Air...

  1. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial...

  2. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed...

  3. 20 CFR 602.41 - Proper expenditure of Quality Control granted funds.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Proper expenditure of Quality Control granted... LABOR QUALITY CONTROL IN THE FEDERAL-STATE UNEMPLOYMENT INSURANCE SYSTEM Quality Control Grants to States § 602.41 Proper expenditure of Quality Control granted funds. The Secretary may, after...

  4. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of...

  5. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of...

  6. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the...

  7. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  8. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  9. 30 CFR 28.32 - Proposed quality control plans; approval by MSHA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Proposed quality control plans; approval by...-CIRCUIT PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.32 Proposed quality control plans; approval by MSHA. (a) Each proposed quality control plan submitted in accordance with...

  10. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate Air Quality Control Region (Oregon-Washington) has been revised to consist of the territorial area... Portland Interstate Air Quality Control Region (Oregon-Washington) will be referred to by...

  11. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.41 Section 81.41 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of...

  12. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.23 Section 81.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the...

  13. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.34 Section 81.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  14. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.30 Section 81.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the...

  15. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.62 Section 81.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the...

  16. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area...

  17. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.49 Section 81.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  18. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  19. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.24 Section 81.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial...

  20. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  1. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.20 Section 81.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist...

  2. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed...

  3. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.49 Section 81.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  4. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.44 Section 81.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of...

  5. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.45 Section 81.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of...

  6. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  7. 20 CFR 602.41 - Proper expenditure of Quality Control granted funds.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Proper expenditure of Quality Control granted... LABOR QUALITY CONTROL IN THE FEDERAL-STATE UNEMPLOYMENT INSURANCE SYSTEM Quality Control Grants to States § 602.41 Proper expenditure of Quality Control granted funds. The Secretary may, after...

  8. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the...

  9. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  10. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of...

  11. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.45 Section 81.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of...

  12. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Quality Control Region. 81.48 Section 81.48 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of...

  13. Quality control procedures in the Italian national forest inventory.

    PubMed

    Gasparini, Patrizia; Bertani, Remo; De Natale, Flora; Di Cosmo, Lucio; Pompei, Enrico

    2009-04-01

    National forest inventories represent a fundamental source of data and knowledge for forestry and environmental policy and allow for the production of national and regional level statistics on forests. The value of these statistics confirms the need for a sampling design that adequately delivers representation by reducing sampling error, but also for a data quality process that limits the non-sampling errors. The article summarizes the quality control procedures of the three sampling phases adopted in the Italian national forest inventory, carried out between 2003 and 2006. The development of an integrated system of actions and controls which are able to limit subjective interpretations, in order to guarantee harmonized information all over the country, was a considerable effort within the overall project. Critical points to be considered were the consistent number of measures and evaluations undertaken during the three inventory phases, the high variability of observed attributes, the consistent number of surveyors involved, and costs of quality control, especially those related to fieldwork. At the end, examples on the overall quality of the classification performed on land cover and vegetation are discussed, as well as the impact of classification errors on the total forest area estimates. PMID:19557227

  14. Quality Control and Quality Assurance in Teacher Training Institutions: Messages from Botswana.

    ERIC Educational Resources Information Center

    Hopkin, A. G.

    1999-01-01

    External factors, such as university affiliation, can help improve teacher-training programs. Using the University of Botswana (UB) as an example, this paper discusses quality control and assurance; evaluates their impact on courses offered, final examinations, and teaching practice; and evaluates operational drawbacks of UB's system, suggesting…

  15. A short term quality control tool for biodegradable microspheres.

    PubMed

    D'Souza, Susan; Faraj, Jabar A; Dorati, Rossella; DeLuca, Patrick P

    2014-06-01

    Accelerated in vitro release testing methodology has been developed as an indicator of product performance to be used as a discriminatory quality control (QC) technique for the release of clinical and commercial batches of biodegradable microspheres. While product performance of biodegradable microspheres can be verified by in vivo and/or in vitro experiments, such evaluation can be particularly challenging because of slow polymer degradation, resulting in extended study times, labor, and expense. Three batches of Leuprolide poly(lactic-co-glycolic acid) (PLGA) microspheres having varying morphology (process variants having different particle size and specific surface area) were manufactured by the solvent extraction/evaporation technique. Tests involving in vitro release, polymer degradation and hydration of the microspheres were performed on the three batches at 55°C. In vitro peptide release at 55°C was analyzed using a previously derived modification of the Weibull function termed the modified Weibull equation (MWE). Experimental observations and data analysis confirm excellent reproducibility studies within and between batches of the microsphere formulations demonstrating the predictability of the accelerated experiments at 55°C. The accelerated test method was also successfully able to distinguish the in vitro product performance between the three batches having varying morphology (process variants), indicating that it is a suitable QC tool to discriminate product or process variants in clinical or commercial batches of microspheres. Additionally, data analysis utilized the MWE to further quantify the differences obtained from the accelerated in vitro product performance test between process variants, thereby enhancing the discriminatory power of the accelerated methodology at 55°C. PMID:24519488

  16. The Role of the Protein Quality Control System in SBMA.

    PubMed

    Rusmini, Paola; Crippa, Valeria; Cristofani, Riccardo; Rinaldi, Carlo; Cicardi, Maria Elena; Galbiati, Mariarita; Carra, Serena; Malik, Bilal; Greensmith, Linda; Poletti, Angelo

    2016-03-01

    Spinal and bulbar muscular atrophy (SBMA) or Kennedy's disease is an X-linked disease associated with the expansion of the CAG triplet repeat present in exon 1 of the androgen receptor (AR) gene. This results in the production of a mutant AR containing an elongated polyglutamine tract (polyQ) in its N-terminus. Interestingly, the ARpolyQ becomes toxic only after its activation by the natural androgenic ligands, possibly because of aberrant androgen-induced conformational changes of the ARpolyQ, which generate misfolded species. These misfolded ARpolyQ species must be cleared from motoneurons and muscle cells, and this process is mediated by the protein quality control (PQC) system. Experimental evidence suggested that failure of the PQC pathways occurs in disease, leading to ARpolyQ accumulation and toxicity in the target cells. In this review, we summarized the overall impact of mutant and misfolded ARpolyQ on the PQC system and described how molecular chaperones and the degradative pathways (ubiquitin-proteasome system (UPS), the autophagy-lysosome pathway (ALP), and the unfolded protein response (UPR), which activates the endoplasmic reticulum-associated degradation (ERAD)) are differentially affected in SBMA. We also extensively and critically reviewed several molecular and pharmacological approaches proposed to restore a global intracellular activity of the PQC system. Collectively, these data suggest that the fine and delicate equilibrium existing among the different players of the PQC system could be restored in a therapeutic perspective by the synergic/additive activities of compounds designed to tackle sequential or alternative steps of the intracellular defense mechanisms triggered against proteotoxic misfolded species. PMID:26572535

  17. Structural Quality Control of Swiss-Type Cheese with Ultrasound

    NASA Astrophysics Data System (ADS)

    Eskelinen, J.; Alavuotunki, A.; Hæggström, E.; Alatossava, T.

    2007-03-01

    A study on structural quality control of Swiss-type cheese with ultrasound is presented. We used a longitudinal mode pulse-echo setup using 1-2MHz ultrasonic frequencies to detect cheese-eyes and ripening induced cracks. Results show that the ultrasonic method posses good potential to monitor the cheese structure during the ripening process. Preliminary results indicate that maturation stage could be monitored with ultrasonic velocity measurements. Further studies to verify the method's on-line potential to detect low-structural-quality cheeses are planned.

  18. Operational Quality Control of SAR Data under the IDEAS Contract

    NASA Astrophysics Data System (ADS)

    Griffiths, Emma; Haria, Kajal; Meadowws, Peter; Miranda, Nuno

    2010-12-01

    Operational Quality Control (QC) of ERS-1/2 Synthetic Aperture Radar (SAR), Envisat's Advanced Synthetic Aperture Radar (ASAR) and the Phased-Array L-band SAR (PALSAR) on board JAXA's Advanced Land Observing Satellite (ALOS) is currently carried out under the Image Data quality Evaluation and Analysis Service (IDEAS). This paper introduces the concept of IDEAS as it applies to SAR QC including the daily and long-term analysis and shows the interaces to related services, including ESA's user-facing Earth Observation (EO) Help Desk

  19. Hierarchical tailoring of strut architecture to control permeability of additive manufactured titanium implants.

    PubMed

    Zhang, Z; Jones, D; Yue, S; Lee, P D; Jones, J R; Sutcliffe, C J; Jones, E

    2013-10-01

    Porous titanium implants are a common choice for bone augmentation. Implants for spinal fusion and repair of non-union fractures must encourage blood flow after implantation so that there is sufficient cell migration, nutrient and growth factor transport to stimulate bone ingrowth. Additive manufacturing techniques allow a large number of pore network designs. This study investigates how the design factors offered by selective laser melting technique can be used to alter the implant architecture on multiple length scales to control and even tailor the flow. Permeability is a convenient parameter that characterises flow, correlating to structure openness (interconnectivity and pore window size), tortuosity and hence flow shear rates. Using experimentally validated computational simulations, we demonstrate how additive manufacturing can be used to tailor implant properties by controlling surface roughness at a microstructual level (microns), and by altering the strut ordering and density at a mesoscopic level (millimetre). PMID:23910314

  20. Controlling a toxic shock of pentachlorophenol (PCP) to anaerobic digestion using activated carbon addition.

    PubMed

    Xiao, Yeyuan; De Araujo, Cecilia; Sze, Chun Chau; Stuckey, David C

    2015-04-01

    Several powdered and granular activated carbons (PACs and GACs) were tested for adsorption of pentachlorophenol (PCP) in bench-scale anaerobic digestion reactors to control the toxicity of PCP to acetoclastic methanogenesis. Results showed that the adsorption capacities of PAC were reduced by 21-54%, depending on the PAC addition time, in the presence of the methanogenic sludge compared to the controls without sludge. As a preventive measure, PAC at a low dose of 20% (mass ratio to the VSS) added 24 h prior to, or simultaneously with, the addition of PCP could completely eliminate the toxic effects of PCP. At the same dose, PAC also enabled methanogenesis to recover immediately after the sludge had been exposed to PCP for 24h. GAC was not effective in enabling the recovery of methanogenesis due to its slow adsorption kinetics; however, at a dose of 80% it could partially ameliorate the toxic shock of PCP. PMID:25665874